Loading...
HomeMy WebLinkAboutItem 2 - ARCH-0764-2019 Project PlansORCUTT MIXED USE 830 ORCUTT ROAD | SAN LUIS OBISPO | CALIFORNIA PLANNING COMMISSION 20.1005 bracket r o c k v i ewsweeney perkins BROADgaribaldimcmillanduncanORCUTT LAURELmutsuhitolawrence * PROJECT SITE 830 ORCUTT ROAD VICINITY MAP SITE AERIAL 830 ORCUTT PROJECT TEAM DEVELOPER | OWNER 830 Orcutt, LLC 9275 N Forty Road Atascadero, CA 93422 ARCHITECT Bracket Architecture Office PO Box 1810 San Luis Obispo, CA 93406 Contact: Bryan Ridley | br@bracketao.com | 805 704 0535 CIVIL ENGINEER Ashley & Vance Engineering, Inc. 1413 Monterey Street San Luis Obispo, CA 93401 Contact: Ken Brown | ken@ashleyvance.com | 805 545 0010 TABLE OF CONTENTS Project Information, Development Statement + Table of Contents Site Context Project Design + Design Exceptions + Revisions Statement Project Data Existing + Demolition Site Plan Tree Removal Plan Site Plan Overall Building Floor Plans Overall Roof Plan Site + Building Sections Typical Dwelling Unit Floor Plans Commercial Unit Floor Plan Character Renderings Elevations Signage Materials + Colors Landscape Plan Landscape Palette Landscape Water Use Calculations Site + Building Furnishings C-1.1 Demolition Plan C-1.2 Site Plan C-2.1 Grading and Drainage Plan PAGE 2 3 4 5 6 7 8 9-11 12 13 14-16 17 18-24 25-27 28-29 30 31 32 33-34 35 36 37 38 DEVELOPMENT STATEMENT This project proposes the demolition of the existing single-family residence and accessory buildings, to prepare the project site for the construction of a mixed-use collection of multi-family residential and commercial use buildings. The fifteen multi-family dwelling units are townhome apartments for rent, and parking is primarily provided in associated private garages with some supplemental surface parking. AFFORDABLE HOUSING + INCENTIVES The project proposes to dedicate 10% of the dwelling units for low income households. Per the calculations that follow, 10% of the proposed dwelling units are reserved and rent-restricted for low income households in accordance with California Government code section 65915. Therefore two 1-bedroom apartments of the fifteen total apartments proposed are provided for such purposes. The density bonus provided for these low income dwelling units is 20%, though the project proposes to require a lesser density bonus of 4.3% to achieve these affordable housing goals on a mixed-use site. This is a privately funded project and does not utilize public funding. Affordable Housing Requirement for Density Bonus and Concession: Provide 10% Low Income 1.5 dwelling units [ 15 dwelling units × 10% ] Affordable Units Provided by this Project: 2 1-bedroom dwelling units 2.0 dwelling units Per SLOMC 17.140.070(A)(1) the developer shall receive one incentive or concession in addition to the density bonus requested. The incentive requested is a relaxation of creek setback standards for the subject property. The relaxation of the creek setback standards is necessary for the inclusion of the low income dwelling units and increased density. The 20’ creek setback combined with the 10’ 3rd story creek setback would result in the elimination of two 2-bedroom apartments which reduces the project’s density below the maximum and has the effect of making the inclusion of affordable housing untenable. This project DOES NOT request residential parking ratios as outlined in SLOMC 17.070.140(K). CEQA STATUS This environmentally benign project is categorically exempt from CEQA per CEQA guideline 15332 as the project satisfies the conditions of a class 32 in-fill development project. PUBLIC ART The requirements of the Public Art Ordinance shall be met through payment of an in- lieu fee and are applicable only to the non-residential building identified in the project plans as Building D. The fee is determined by the amount equal to one-half of one percent (0.5%) of that portion of the total construction costs in excess of $100,000, not to exceed $50,000 for each building permit. The expected project cost is $214,250 for the 1,714 square foot building and therefore: ($214,250-$100,000) × 0.5% = $571.25 2 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission SITE CONTEXT The project site is 0.57 acres situated along the north side of a broad section of Orcutt Road in the Service Commercial (C-S) zone. The C-S zoning is applied in this vicinity only on the north side of Orcutt Road and only where properties abut the right-of- way. Further removed from the activity of Orcutt Road to the north Manufacturing zoning takes over, defined by a haphazard collection of simple utilitarian buildings. To the south, across the street, various residential planned developments have been constructed or are under construction, forming clusters of townhomes and apartments. Current pedestrian activity along Orcutt Road is limited but expected to increase with the construction of the nearby mixed use “Connect” project to the east and with this development as well, with many services available to the west centered around the intersection of Orcutt Road and Broad Street. Presently, a single-story home built in 1949 (per SLO County Assessor’s Office) occupies the site with an accessory detached garage. The home is setback from the right-of-way, screened by vegetation, and does not create any sense of neighborhood or prominence. It is a leftover structure that has outlived the changes in development patterns and land use updates and therefore will be demolished or removed entirely from the site to allow for the proposed development. It lacks character defining features and doesn’t demonstrate any need for preservation. 3197 DUNCAN3076 DUNCAN CORNER OF ORCUTT + MACMILLAN3055 MACMILLAN 3195 MACMILLAN 810 ORCUTT 830 ORCUTT 3138 MACMILLAN 3 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission PROJECT DESIGN Orcutt Mixed Use is a collection of four buildings -three residential (A, B, C), one commercial (D)- to establish a mixed use site in the Service-Commercial (C-S) zone along Orcutt Road. The buildings are arranged to provide and maintain “logical and safe access to the site” [CDG 3.1.A(5)] along with clear pedestrian circulation paths in between to well-defined individual townhome and commercial suite entries. [CDF 3.1.B(2g)] The simplicity of the building footprints allows for subtle and clever patterning of pronounced building offsets from unit to unit, with larger scale roof slope gestures carving a serrated roofline against the sky. The composite roof form offers a collection of pitched roofs that are “multi-planed to avoid large monotonous expanses”.” [CDG 3.1.B(5b)] At all times the building walls and roofs harmonize rhythmically and express dynamic variation without adding unnecessary complexity and decoration. The public frontage of the project is framed by a building of rowhouses to the west, and the commercial building to the east. The 3-story mass of residential building A is softened with material shifts, patterning, and smaller projecting masses to scale down and create “interesting rooflines, building shapes, and patterns of shade and shadow.” [CDG 3.1.A(1)] This building utilizes the affordable housing incentive request to relax the 50’ setback for ground floor residential in mixed use projects. Building design and style in the immediate surroundings is eclectic with largely scaled, simple, and boxy structures comprising the manufacturing and service-commercial areas. Flat and pitched roofs are common, as are broad walls with simple offsets for shade and shadow. Orcutt Mixed Use adopts a contemporary interpretation of the surrounding context, [CDG 3.1.C] translating the simple forms through the lens of residential and small scale commercial patterns. This results in a collection of buildings compatible with the immediate context but that also positions a modern architecture appropriate for denser, mixed use developments. Materials in use at nearby properties on the north side of Orcutt Road include stucco, pigmented and painted concrete masonry units, horizontal clapboard siding, corrugated sheet metal, and vertical formed sheet metal panels. Across the street, where development has formed in residential clusters detached from the streetscape, materials are far more traditionally applied in what could be called Mediterranean and Cottage flavors. The project borrows from and interprets the contextual palette of materials from the industrial use of sheet metal to a more appropriate and durable use of stucco and fiber cement boards and panels for this mixed use site. Ribbed integral color fiber cement panels echo the scale of corrugated sheet metal. Fiber cement vertical board and batten follows the pattern of formed sheet metal panels. Stucco offers a clean background and avoids excessive and competing textures. Scaled, textured, and integrally colored fiber cement planks present a durable and warm vision of natural wood without the maintenance and durability concerns. Body colors are light with medium to medium- dark tones joining the architecture for differentiation and emphasis. Landscape is part of the overall site design and balances the buildings and hardscape with the living and seasonable beauty of various plantings. [CDG 3.1.C(3)] Along with the five street trees proposed along Orcutt Road, several additional trees are proposed to provide soft balance with the multi-story buildings. At the grade plane a blend of meadow grasses and shrubs establish layered transitions to building surfaces and guide circulation paths. All landscape plantings are drought-tolerant. Signs are located to identify the specific uses on site and offer an appropriate scale of identification both to pedestrians and vehicles. [CDG 3.1.A(6)] The trash enclosure is located adjacent to the vehicular entry of the site for ease of access and to minimize disruption to the residential community on pick up days. The design of the enclosure echoes the form and material palette of the buildings and conceals the waste bins from view, while also screening the surface lot parking from the public sidewalk. DESIGN EXCEPTIONS Following the City of San Luis Obispo’s Mixed-Use Development Guidelines the project was designed so that the pedestrian environment is enhanced along Orcutt Road with dense landscaping, human scaled building and site entry elements. [17.70.130(D)(1) (a)] Because of the relatively narrow frontage width of the site the buildings do not orient parallel to the street -if they did they would wall off the entire depth of the site- instead the two lead buildings present narrower facades with pedestrian entries and leave the center of the site open visually and for vehicular and pedestrian circulation. Although the Community Design Guidelines discourage building lengths exceeding 150’ in length, [CDG 3.1.C(1)] building A is proposed at 160’ from front to back. This marginal extra length allows for the inclusion of the second low income dwelling unit and will be largely imperceptible as the extra building length is located 165’ from the right-of-way and at the rear of adjacent properties. This perpendicular building arrangement also allows for the garages to not dominate visually as they do not directly face the street. Many of the nearby properties employ this site configuration of building length perpendicular to the street. REVISIONS STATEMENT Following the public hearing of the San Luis Obispo Architectural Review Commission on July 6, 2020, the Orcutt Mixed Use project was revised to provide dedicated common outdoor space, enhanced landscaping, and additional material definition to visually activate the building elevations interior to the site. This was accomplished by: • Reducing the depth of the commercial building to create open space between Building D and Building C. • The open space in between the building is divided by a structured planter into a sheltered residential walkway and an active common courtyard with enhanced paving, landscaped edges, and accent trees. • Extended lengths of concrete walkways were narrowed to allow for a pairing of hardscape and walkable ground cover while maintaining 6’ minimum width. • The area adjacent to Sydney Creek along side residential Buildings B and C provides an elongated passive open space between the buildings and the adjacent off-site vegetation and new drought-tolerant plantings. • The variety of plantings was increased by adding walkable ground cover and another accent tree specimen. • The building elevations interior to the project were modified in material placement to create an aggregate patterning of the indigo and wood-look fiber cement siding elements. This reduces repetition and provides a visual “downbeat” when entering the mixed use site. Following the 2nd public hearing of the ARC on August 17, 2020 and Tree Committee on September 28, 2020: • The rhythm of the building materials along the drive aisle was changed to an A-B-A-B pattern for the indigo and wood-look fiber cement siding elements. • In-ground planters were added along the drive aisle to add soft landscape separations between the garages. • The street tree species was updated to a larger growth specimen, Chinese Pistache. • Two more Coast Live Oaks were added to the ephemeral creek area. 4 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission PROJECT DATA Address: 830 Orcutt Road APN: 053-202-026 Zoning: C-S Service Commercial Adjacent Zoning: C-S (east and west) M (north) R-4-PD and C-C-PD (south across right-of-way) Lot Area: 24,920 square feet (0.57 acres) Current Use: Single Family Residential Proposed Use: Mixed-Use Site with Residential and Commercial Buildings Gross Building Areas: Building A 3,031 sf Garage, 13,230 sf Residential Building B 1,122 sf Garage, 5,011 sf Residential Building C 1,122 sf Garage, 5,011 sf Residential Building D 1,500 sf General Retail and Personal Services Lot Coverage: 75% Allowed 18,690 square feet 46% Proposed 11,436 square feet Floor Area Ratio: 1.5 Allowed 37,380 square feet 1.1 Proposed 26,971 square feet [ 31,171 sf total area – 4,200 sf for required parking ] Density Allowed: C-S Zone 13.7 density units [ 24 du/ac × 0.57 ac ] Density Bonus 16.48 density units [ 13.7 du × 20% for 10% low income per Table 8-2 ] 17.0 density units when rounded per SLOMC 17.140.040(B) Density Proposed: 2 1-bedroom dwelling units 1.32 density units [ 2 x 0.66 du ] 13 2-bedroom dwelling units 13.0 density units [ 13 x 1.0 du ] 15 total dwelling units 14.32 density units Affordable Housing: Requirement Provide 10% Low Income dwelling units, 1.5 dwelling units [ 15 dwelling units × 10% ] Provided 2 Low Income 1-bedroom dwelling units, Unit 01 and Unit 09 Building Height: Allowed 20’ at 10’ street yard setback, 35’ at 15’ street yard setback Proposed 20’ maximum at 10’ street yard setback, 35’ maximum at 15’ street yard setback Construction Type + Occupancy: Type VB Occupancy Townhouses R-3 [ Buildings A-C ], Business B and Mercantile M [ Building D ] Common Open Space Active Residential Courtyard 640sf Passive Pedestrian Walk 1,240 sf Total 1,880 sf Vehicle Parking Required: 2 1-bedroom dwelling units 1.5 [ 2 × 0.75 per bedroom ] 13 2-bedroom dwelling units 19.5 [ 26 × 0.75 per bedroom ] Guest 3.0 [ 1 per 5 dwellings × 15 dwellings ] Commercial 5.0 [ 1 per 300 sf x 1,500 sf ] Subtotal 30 spaces Bicycle Reduction 3 spaces [ 1 per 5 bicycles × 15 addition bicycle spaces to reduce commercial and guest parking demand, 10% maximum ] Total after reductions 27 spaces Vehicle Parking Provided: Standard Spaces in Garages 28 [ 2 per 2-bedroom dwelling, 1 per 1-bedroom dwelling] Surface Parking 3 standard, 1 van accessible Total 32 spaces Electric Vehicle Charging: EV Ready 3 [ 10% of 30 required spaces ] EV Capable 15 [ one space for each residential garage provided per CalGreen ] Motorcycle Parking: Required 2 [ 1 per 20 parking spaces × 30 spaces required ] Provided 2 accounted for in any of the private garages where there is an excess of 7 parking spaces provided over the requirement of 21 parking spaces Bicycle Parking: Residential 30 [ 2 per dwelling × 15 dwellings located in garages] Guest 3 [ 1 per 5 dwellings × 15 dwellings ] Commercial 1.5 [ 1 per 1,000 sf × 1,500 sf ] For Parking Reduction 15 [ equivalent to 3 vehicle parking space reduction ] Total 50 bicycle spaces [ 30 located in garages, 5 long-term, 15 short-term ] Accessible Dwelling Units: Required 2 dwellings [ 15 dwellings × 10%, per CBC 1102A.3.1 at least 10% of the number of multi-story apartments in buildings with no elevator on a site must comply with subsections 1-4 as applicable ] Provided Unit 10 and Unit 11 fulfill accessible dwelling unit requirements with entry level powder room and habitable room 5 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission EXISTING + DEMOLITION SITE PLAN 1” = 20’-0” EXISTING RESIDENCE TO BE DEMOLISHED EXISTING PAVED AREAS TO BE DEMOLISHED, TYPICAL ORCUTT ROADEXISTING GARAGE TO BE DEMOLISHED TREE, SHRUBS, AND GROUNDCOVER TO BE REMOVED, TYPICAL OF ALL LANDSCAPE ON-SITE. SEE TREE REMOVAL PLAN FOR SIZE AND SPECIES. SEE LANDSCAPE PLAN FOR NEW TREES AND OTHER PLANTINGS SITE UTILITIES TO BE INSTALLED PER CIVIL ENGINEERING DESIGN OVERHEAD UTILITIES TO BE REMOVED EUCALYPTUS TREES TO BE REMOVED OFF-SITE TREES TO REMAIN 20’ CREEK SETBACK TOP OF BANK CONTOUR -AND- LINE OF AVERAGED TOP OF BANK PER SITE VISIT WITH NATURAL RESOURCES MANAGER ON JANUARY 13, 2020 [SLOMC 17.70.030(C)] 6 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission TREE REMOVAL PLAN 1” = 20’-0”ORCUTT ROADONSITE TO REMOVE 68” EUCALYPTUS 56” EUCALYPTUS 60” EUCALYPTUS 36” PEPPER 24” OAK 10” PINE 12” REDWOOD 10” REDWOOD 6”, 8”, 10” PALM 14” REDWOOD 13” REDWOOD 16” PEPPER 16” PEPPER 8” PEPPER 14” PEPPER 6” PEPPER 20” PEPPER 8” PEPPER OFFSITE TO REMAIN 24” OAK 72” PEPPER 18” OAK 12” OAK 8”, 12”, 12” EUCALYPTUS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. A. B. C. D. E. TREE INDEX 1 2 3 BA CD 6 5 7 8 9 101112 13 14 16 17 18 E 15 4 ALL SHRUBS AND GROUNDCOVER ON-SITE TO BE REMOVED NEIGHBORING TREES OVERHANGING THE PROPERTY LINE TO BE PRUNED UNDER THE SUPERVISION OF A CERTIFIED ARBORIST NEIGHBORING TREES OVERHANGING THE PROPERTY LINE TO BE PRUNED UNDER THE SUPERVISION OF A CERTIFIED ARBORIST 7 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission UNIT 08 SINGLE-STORY COMMERCIAL UNIT 15 UNIT 14 UNIT 12 UNIT 11 UNIT 13 FIRE ACCESS ROAD UNIT 10 UNIT 07 UNIT 06 UNIT 05 UNIT 04 UNIT 03 UNIT 02 UNIT 01 UNIT 09 SITE PLAN 1” = 20’-0” SPLIT RAIL FENCE SETBACK FROM TOP OF BANK NOTED AT EACH BUILDING CORNER SITE PRIVACY FENCE AT NORTH PROPERTY LINE SINGLE MANEUVER FROM GARAGE (REVERSE) SINGLE MANEUVER FROM GARAGE (REVERSE) ELECTRIC UTILITY TRANSFORMER EV READY PARKING (3) REQUIRED 10’ SETBACK FOR BUILDINGS < 20’ IN HEIGHT 50’ SETBACK FOR GROUND LEVEL DWELLING UNITS, DESIGN EXCEPTION PER SLOMC 17.70.130(D)(1)(a) 15’ SETBACK FOR BUILDINGS > 20’ IN HEIGHT BICYCLE PARKING, (4) LONG TERM BICYCLE PARKING, (1) LONG TERM STREET LIGHT PER ENGINEERING STANDARDS 7520 + 7910 FIRE RISER ROOM WITH EXTERIOR DOOR ACCESS, FDC AT SOUTH WALL DOUBLE-DETECTOR CHECK VALVE SCREENED BY LANDSCAPE COMMON OPEN SPACE COURTYARD COMMON OPEN SPACE PASSIVE PEDESTRIAN WALK BICYCLE PARKING, (12) SHORT TERM BICYCLE PARKING, (3) SHORT TERM 5’ SETBACK FOR PARKING LOTS AND SIGNS SITE PRIVACY FENCE + GATE AT WEST PROPERTY LINE 6’ WIDE PATHWAYS INCLUDING 18” WALKABLE GROUND COVER STRIP IN GROUND PLANTER, SEE LANDSCAPE PLAN TRASH, RECYCLING + ORGANICS ENCLOSURE, COVERED REQUESTED EXCEPTION OF CREEK SETBACKS [ 20’ + 10’ AT UPPER LEVEL ] BY AFFORDABLE HOUSING INCENTIVE TOP OF BANK CONTOUR -AND- LINE OF AVERAGED TOP OF BANK PER SITE VISIT WITH NATURAL RESOURCES MANAGER ON JANUARY 13, 2020 [SLOMC 17.70.030(C)] 8 0 5 10 20 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission 38'-9"40'-0"10'-112"5'-0"36'-0"36'-0"24'-0"59'-1112"59'-1112"11'-2"36'-0"15'-6" 160'-212" 10'-10"7'-2"26'-0"22'-012" SINGLE-STORY COMMERCIAL UNIT 15 UNIT 14 UNIT 12 UNIT 11 UNIT 13 UNIT 10 FIRST FLOOR OVERALL PLAN 1” = 20’-0” UNIT 01 UNIT 09 UNIT 08 UNIT 07 UNIT 06 UNIT 05 UNIT 04 UNIT 03 UNIT 02 SEE PAGES 14-17 FOR PLAN ENLARGEMENTS LOW INCOME LOW INCOME ACCESSIBLEACCESSIBLE9 0 5 10 20 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission 39'-0"39'-0"24'-0" 38'-9"40'-0"10'-112"5'-0"160'-212"38'-0"15'-6" 7'-10"59'-1112"59'-1112"11'-2"5'-2"SECOND FLOOR OVERALL PLAN 1” = 20’-0” SINGLE-STORY COMMERCIAL UNIT 15 UNIT 14 UNIT 12 UNIT 11 UNIT 13 UNIT 10 UNIT 08 UNIT 07 UNIT 06 UNIT 05 UNIT 04 UNIT 03 UNIT 02 UNIT 01 UNIT 09 MECH SEE PAGES 14-17 FOR PLAN ENLARGEMENTS MECHANICAL EQUIPMENT AREA, TYPICAL, SET IN FROM PERIMETER TO LIMIT VISIBILITY. 10 0 5 10 20 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission 39'-0"39'-0"24'-0"59'-1112"59'-1112"11'-2"160'-212"38'-0"5'-2"15'-512" 7'-10" THIRD FLOOR OVERALL PLAN 1” = 20’-0” UNIT 15 UNIT 14 UNIT 12 UNIT 11 UNIT 13 UNIT 10 UNIT 08 UNIT 07 UNIT 06 UNIT 05 UNIT 04 UNIT 03 UNIT 02 UNIT 01 UNIT 09 SEE PAGES 14-17 FOR PLAN ENLARGEMENTS 11 0 5 10 20 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission ROOF OVERALL PLAN 1” = 20’-0” MECHANICAL EQUIPMENT AREA, TYPICAL, SET IN FROM PERIMETER TO LIMIT VISIBILITY. ROOF APERTURE 12 0 5 10 20 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission EAST-WEST SECTION 1/16”=1’0” NORTH-SOUTH SECTION 1/16”=1’0” BUILDING CBUILDING B BUILDING A BUILDING D BUILDING D MECHANICAL EQUIPMENT AREA, TYPICAL, SET IN FROM PERIMETER TO LIMIT VISIBILITY. 13 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission 2ND FLOOR 653 sf 3RD FLOOR 653 sf UNIT AREA 1,598 sf TOTAL 1ST FLOOR 292 sf [368 GARAGE] BED 2STAIRS STAIRSSTAIRSTYPICAL 2-BEDROOM TOWNHOME FLOOR PLANS | UNITS 02-07 AND 12-15 1/8”=1’0” BED 1 LIVING KITCHEN+ DINING DEN GARAGE ENTRY BATH STORAGE 14 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission 1ST FLOOR 292 sf [368 GARAGE] 2ND FLOOR 672 sf 3RD FLOOR 672 sf UNIT AREA 1,636 sf TOTAL ACCESSIBLE 2-BEDROOM TOWNHOME FLOOR PLANS | UNITS 10 + 11 1/8”=1’0” BED 2STAIRS STAIRSSTAIRSBED 1 LIVING KITCHEN+ DINING DEN GARAGE ENTRY BATH STORAGE 2-BICYCLE OVER- HEAD HOIST 15 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission TYPICAL ONE-BEDROOM UNIT TOWNHOME FLOOR PLAN | UNITS 01 + 09 1/8”=1’0” 1ST FLOOR 161 sf [195 GARAGE] UNIT AREA 734 sf TOTAL 2ND FLOOR 335 sf 3RD FLOOR 238 sf BATH LDRY STAIRS KITCHEN GARAGE ENTRY LIVING PWDR BED ROOF STORAGE 16 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission 32'-9"40'-0" 10'-0"30'-0"38'-9"5'-0"1'-0"GROUND FLOOR 1,500 sf RESTROOM RESTROOM SUITE 02 SUITE 01 COMMERCIAL UNIT FLOOR PLAN 1/8”=1’0” FIRE RISER CLOSET ELECTRICAL CLOSET 17 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission ORCUTT ROAD VIEW AT BUILDING A 18 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission ORCUTT ROAD VIEW AT BUILDING D 19 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission SITE ENTRY AT BUILDING D 20 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission SITE ENTRY AT BUILDING A 21 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission SITE ENTRY AT DRIVE AISLE 22 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission MIXED-USE CONNECTION 23 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission RESIDENTIAL COURTYARD LOOKING WEST 24 A bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission RESIDENTIAL COURTYARD LOOKING EAST 24 B bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission EAST ELEVATION 1/16”=1’-0” SOUTH ELEVATION 1/16”=1’0” NICHIHA VINTAGEWOOD FIBER CEMENT PANEL- SPRUCE VINYL WINDOW FRAME- WHITE MERLEX STUCCO FINISH MEDIUM SAND TEXTURE- CRYSTAL SKY NICHIHA RIBBED FIBER CEMENT PANEL- INDIGO SHEEET METAL MECHANICAL SCREEN WALL MOUNTED GREENSCREEN PANELS MERLEX STUCCO FINISH - TITANIUM NICHIHA FIBER CEMENT BOARD + BATTEN - IRON ORE EAVES | MERLEX STUCCO FINISH - TITANIUM 25 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission WEST ELEVATION 1/16”=1’0” NORTH ELEVATION 1/16”=1’0” MERLEX STUCCO FINISH MEDIUM SAND TEXTURE- CRYSTAL SKY NICHIHA VINTAGEWOOD FIBER CEMENT PANEL- SPRUCE CONTROL JOINT PATTERINING NICHIHA RIBBED FIBER CEMENT PANEL- INDIGO 26 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission EAST ELEVATION DRIVE AISLE 1/16”=1’0” WEST ELEVATION DRIVE AISLE 1/16”=1’0” 27 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission SOUTH ELEVATION SIGNS 1/8”=1’0” SIGN SUMMARY WALL SIGN 01 11’ x 3’ = 33 sf [ approx. 8% of wall area ] WALL SIGN 02 [ see next page ] 4’ x 4’ = 16 sf WALL SIGN 03 [ see next page ] 4’ x 4’ = 16 sf MONUMENT | SITE SIGN 4’ x 4’ = 16 sf TOTAL SIGN AREA 81 sf [ 200 sf allowed in C-S zone ] METAL NUMBERS WITH STANDOFFS WALL SIGN 01 TENANT A MONUMENT | SITE SIGN 28 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission WEST ELEVATION SIGNS 1/8”=1’0” DIMENSIONAL NUMBERS + LETTERS WALL SIGN 02 TENANT A WALL SIGN 03 TENANT B 29 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission 1743 S. LA CIENEGA BLVD. LOS ANGELES, CA. 90035 T - 800.450.3494 www.greenscreen.com Whole Foods - San Jose, CA On a new single story retail building, a simple pattern of greenscreen® wall mounted panels is used with a variety of vines to create a landscape presence and soften the hardscape environment. Hardiness Zone 9b Installed 20101743 S. LA CIENEGA BLVD. LOS ANGELES, CA. 90035 T - 800.450.3494 www.greenscreen.com Rolex Building Parking area - Beverly Hills, CA Wallmounted greenscreen® panels on a simple stucco wall reach to twelve foot height growing from only a narrow twelve inch planting bed. Creeping Fig Hardiness Zone 10b Installed 1998LEGEND 1-2 Merlex Stucco Finish Medium Sand Texture - X-50 Crystal White 3-4 Nichiha Vintagewood Fiber Cement Panel - Spruce 5-6 Nichiha Ribbed Fiber Cement Panel - Indigo 7 Nichiha Fiber Cement Board + Batten 8 Wall Mounted Greenscreen Panels 9 Merlex Stucco Finish - P.1661 Titanium [Trash Enclosure] 10 Dark Gray - SW 7069 Iron Ore [Fascia, Trim, And Garage] 11 Light Gray - SW 7660 Earl Grey 12 Accent Pink - SW6605 Charisma [Exterior Doors] 13 Vinyl Window Frames, White 51 7 8 8 6 13 2 3 4 MATERIALS + COLORS 12 109 11 30 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission T 234 1 LANDSCAPE PLAN 1/16”=1’0” BUILDING A BUILDING D BUILDING CBUILDING B ACCENT TREES SPLIT RAIL FENCE ACCENT TREES GROUNDCOVER EDGE TO 6’ WALKWAYS SHADE TREE IN-GROUND PLANTERS SITE PRIVACY FENCE 6’ MAX. BORDER SHRUB ASPHALT DRIVE AISLE CONCRETE FLATWORK CONCRETE APRON STREET TREE, TYP OF (5) CONCRETE PADS WITH GROUNDCOVER BETWEEN RAISED PLANTER MEADOW GRASSES SCREEN SHRUBS BENCH SPLIT RAIL FENCE SHADE TREES 31 0 5 10 20 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1124 Planning Commission LANDSCAPE PALETTE 1 3 4 3 4 5 6 LEGEND Use | Common Name Botanical Name Water Use 1 Street Tree | Chinese Pistache Pistacia chinensis L 2 Shade Tree | Coast-Live Oak Quercus agrifolia L 3 Accent Tree | Western Redbud Cercis occidentalis L 4 Planter Shrub | New Zealand Flax Phormium ‘Black Adder’ M 5 Planter Shrub | New Zealand Flax Phormium ‘Yellow Wave’ M 6 Border Shrub | Hummingbird Sage Salvia spathacea L 7 Border Shrub | Mediterranean Spurge Euphorbia characias L 8 Screen Shrub | Pittosporum Pittosporum tenuifolium M 9 Meadow | Orange New Zealand Sedge Carex testacea L 10 Meadow | Berkeley Sedge Carex divulsa L 11 Groundcover | Silver Carpet Dymondia margaretae L 12 Accent Tree | Golden Spirit Smoke Cotinus coggygria ‘Ancot’ L 10 9 2 8 7 12 11 32 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission Instructions Cells with blue background are for entering data Results show in cells with tan background Errors will show in RED text. 1) Select type of project from drop down menu Type of Project (ETAF)*Non-Residential For mixed-use projects please select Non-residential.ETo of City from MWELO data 43.80 ETo (inches/year) 2) Enter spray irrigated landscape area in square feet 0 Overhead Landscape Area (ft2) 3) Enter drip irrigated landscape area in square feet 3212 Drip Landscape Area (ft2) 4) Enter Special Landscape Area (SLA) in square feet 0 SLA (ft2) Total Landscape Area (LA)3,212 ft2 If project is using only Recycled Water, enter all data in SLA field. Do not enter values in Overhead and Drip Landscape fields. *Residential projects will have an Evapotranspiration Adjustment Factor (ETAF ) of 0.55. Non-residential projects will have an ETAF of 0.45. Results: 4) MAWA results appear in the tan cells (ETo) x (0.62) x [(ETAF x LA) + (1.0 - ETAF) x SLA]39,251.3 Gallons per year 52 HCF (Hundred Cubic Feet) per year 0.120 Acre-feet per year Definitions MAWA Maximum Applied Water Allowance ETo Evapotranspiration Reference Value. Standard measurement of environmental parameters which affect the water use of plants. Taken from State MWELO. 0.62 Conversion Factor (acre-inches/acre per year converted to gallons/square foot per year) ETAF A factor given to project types, when applied to ETo, adjusts for plant factors and irrigation efficiency. The ETAF for new and existing (non-rehabilitated) Special Landscape Areas shall not exceed 1.0. The ETAF for existing non-rehabilitated landscapes is 0.8. LA Landscape Area. All planting areas, turf areas, and water features in a landscape design plan. SLA Special Landscape Area. An area of the landscape dedicated solely to edible plants, recreational areas, areas irrigated with recycled water, or water features using recycled water, and areas dedicated to active play such as parks, sports fields, golf courses, and where turf provides a playing surface. San Luis Obispo Tan Cells Show Results Enter Value in Blue Cells Maximum Applied Water Allowance Calculations LANDSCAPE WATER USE CALCULATIONS 33 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission Instructions Plant Water Use Type Plant Factor Cells with blue background are for entering data Very Low 0 - 0.1 Results show in cells with tan background Low 0.1 - 0.3 Errors will show in RED text.Moderate 0.3 - 0.6 High 0.6 - 1.0 1) Enter Plant Factor (PF) The plant factor used shall be from WUCOLS or from horticultural researchers with academic institutions or professional associations as approved by the California Department of Water Resources (DWR). (23 CCR § 492.4)Hydrozone Plant Water Use Type (low, moderate, high) Plant Factor (PF) Hydrozone Area (HA) (ft2) Without SLA Enter Irrigation Type (PF x HA (ft2))/IE Zone 1 Low 0.15 605 Drip Irrigation 112.04 2) Enter non-SLA Hydrozone Area (HA) in square feet.Zone 2 Low 0.15 2,224 Drip Irrigation 411.85 If project uses Recycled Water exclusively, enter all Hydrozone information.Zone 3 Moderate 0.45 275 Drip Irrigation 152.78 3) Select Irrigation Type from drop-down menu.Zone 4 Moderate 0.45 108 Drip Irrigation 60.00 Drip System Irrigation Efficiency (IE) 0.81 Zone 5 Spray System Irrigation Efficiency (IE) 0.75 Zone 6 Zone 7 4) ETWU results show at the bottom of the page Zone 8 Zone 9 Total Landscape Area (LA) must be equal to the LA in the MAWA calculator.Zone 10 ETWU must be equal to or less than MAWA. Mistakes will show in RED.Zone 11 Zone 12 Zone 13 Definitions Zone 14 ETWU Estimated Total Water Use. Total water used for lanscape.Zone 15 ETo Evapotranspiration Reference Value Zone 16 0.62 Conversion Factor. Acre-inches to Gallons-Square foot.Zone 17 PF Plant Factor. Multiplied by ETo to estimate amount of water needed by plants Zone 18 HA Hydrozone. Lanscaped area having plants with similar water needs.Zone 19 IE Irrigation Efficiency. 0.75 for overhead spray and 0.81 for drip systems.Zone 20 SLA Special Lanscape Area HA 3,212 736.67 SLA Total LA 3,212 Results:MAWA=39,251.3 ETWU=20,004.9 Gallons 26.7 HCF (Hundred Cubic Feet) per year 0.0614 Acre-feet per year Estimated Total Water Use Enter Values in Blue Cells Tan Cells Show Results ETWU complies with MAWA ETo x 0.62 x [((PF x HA)/IE) + SLA] LANDSCAPE WATER USE CALCULATIONS 34 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission SITE + BUILDING FURNISHINGS 1 4 5 623 LEGEND 1 Wall Mount Downlighting, Night-Sky Compliant 2 Vertical Board Fence 3 Split Rail Fence 4 Bicycle Hoist (2 per dwelling unit, mounted to garage ceiling), by RAD 5 Bicycle Rack, by Peak 6 Bicycle Locker, by Madrax 35 bracketORCUTT MIXED USE 830 Orcutt Street | San Luis Obispo 20.1005 Planning Commission X X X X X X X X X X X X X X X X W W W W W W W W W W W W W W W W W W W WWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE GGSSSSSSSSSSSSSSSSA B C D E F G H I A B C D E F G H I 1 2 3 4 5 6 7 C:\Egnyte\Shared\Sun\All Jobs\2019 All Jobs\19607 - 830 Orcutt (Civil)\02_Working Drawings\Preliminary\02_ONSITE\DEMOLITION SHEET.dwg, C-1.1, Jul 23, 2020 4:46pm, FernandoPlan Prepared By:The use of these plans and specifications shall berestricted to the original site for which they wereprepared and publication thereof is expressly limited tosuch use. Reproduction or publication by any method,in whole or in part, is prohibited. Title to these plans andspecifications remain with Ashley & Vance Engineering,Inc. without prejudice. Visual contact with these plansand specifications shall constitute prima facie evidenceof the acceptance of these restrictions.Ashley&VanceG, C1413 Monterey StreetSan Luis Obispo, CA 93401 (805) 545-0010www.ashleyvance.comC I V I L S T R U C T U R A LRevisions: Project Engineer: Project Manager: Date: AV Job No: Scale:PER PLAN Sheet Size:24" x 36" Ext: N 010 10 20 HORIZONTAL SCALE: 1" = 10' DEMOLITION NOTES EXISTING TREE TO BE REMOVED AND DISCARDED. EXISTING FENCE TO BE REMOVED AND DISCARDED EXISTING CONCRETE/BRICK WORK/ ROACK TO BE REMOVED AND DISCARDED EXISTING OVERHEAD UTILITY TO BE REMOVED PER PG&E HANDOUT PACKAGE AND SPECIFICATIONS EXISTING STRUCTURE TO BE DEMOLISHED, REMOVED, AND DISCARDED EXISTING ASPHALT TO BE DEMOLISHED, REMOVED, AND DISCARDED EXISTING GAS LINE/GAS METER TO BE REMOVED AND DISCARDED EXISTING TO REMAIN. PROTECT IN PLACE EXISTING CONCRETE DRIVEWAY AND/OR SIDEWALK TO BE REMOVED AND DISCARDED EXISTING WATER METER TO BE REMOVED AND SALVAGED EXISTING UTILITY VAULT TO BE REMOVED AND DISCARDED PER UTILTY HANDOUT AND SPECIFICATIONS EXISTING LANDSCAPING TO BE REMOVED AND DISCARDED 1 2 3 4 5 6 7 8 9 10 11 12 GENERAL NOTES: 1.ALL DEMOLITION AND GRADING SHALL BE IN COMPLIANCE WITH THE RECOMMENDATIONS CONTAINED IN THE SOILS REPORT PREPARED BY GEO SOLUTIONS, INC. FILE NO. SL11240-1, DATED JUNE 18, 2019 AND ALL ADDENDA TO THE REPORT SHALL BE CONSIDERED PART OF THESE PLANS. CONTRACTOR SHALL CONTACT SOILS ENGINEER PRIOR TO START OF DEMOLITION WORK. 2.SEE ARCHITECT'S PLAN FOR ADDITIONAL DEMOLITION AND REMOVAL INFORMATION. 3.SEE TREE PROTECTION AND REMOVAL PLAN FOR ADDITIONAL TREE PROTECTION AND REMOVAL INFORMATION. DIAL TOLL FREE811 OR (1-800-227-2600) AT LEAST TWO DAYS BEFORE YOU DIG ORCUTT MIXED USE830 ORCUTT STREETSAN LUIS OBISPO, CAKBB FG3 07.23.2020 19607 DEMOLITION PLAN C-1.1 1 . 2 . 3 . 4 . 5 . 119 1 1 1 1 11 1 11 1 1 1 1 1 1 1 14" REDWOOD BRUSH BRUSH 10" REDWOOD 12" REDWOOD BRUSHBRUSH 24" OAK 36" PEPPERWOOD 60" EUCALYPTUS 56" EUCALYPTUS 68" EUCALYPTUS 1 1 1 2 2 2 2 1 1 2 2 2 FENCE FENCE FENCE FENCE FENCE FENCE DOG RUN 2 FENCE 4 OVERHEAD UTILITIES 3 3 BRICK CONCRETE3CONCRETE 3 ROCK 3BRICK 3BRICK 3 BRICK 3 CONCRETE 16" PEPPERWOOD 16" PEPPERWOOD 18" PEPPERWOOD 6" TREE 14" PEPPERWOOD 8" PEPPERWOOD 5 HOUSE 5 GARAGE SHED 5 6 AC 6 AC 6 AC 6 AC 6 AC 6 AC 2GAS 8 9 99 910 7 3 12 12 12 12 11 ORCUTT ROAD 36 T2341X X X X X X X X X X X X X X X X W W W W W W W W W W W W W W W W W W W WWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSGGSSSSSSSSSSSSSSSSABCDEF G H I A B C D E F G H I 1 2 3 4 5 6 7 C:\Egnyte\Shared\Sun\All Jobs\2019 All Jobs\19607 - 830 Orcutt (Civil)\02_Working Drawings\Preliminary\02_ONSITE\DEMOLITION SHEET.dwg, C-1.2, Jul 23, 2020 4:46pm, FernandoPlan Prepared By:The use of these plans and specifications shall berestricted to the original site for which they wereprepared and publication thereof is expressly limited tosuch use. Reproduction or publication by any method,in whole or in part, is prohibited. Title to these plans andspecifications remain with Ashley & Vance Engineering,Inc. without prejudice. Visual contact with these plansand specifications shall constitute prima facie evidenceof the acceptance of these restrictions.Ashley&VanceG, C1413 Monterey StreetSan Luis Obispo, CA 93401 (805) 545-0010www.ashleyvance.comC I V I L S T R U C T U R A LRevisions: Project Engineer: Project Manager: Date: AV Job No: Scale:PER PLAN Sheet Size:24" x 36" Ext: N 010 10 20 HORIZONTAL SCALE: 1" = 10' DIAL TOLL FREE811 OR (1-800-227-2600) AT LEAST TWO DAYS BEFORE YOU DIG ORCUTT MIXED USE830 ORCUTT STREETSAN LUIS OBISPO, CAKBB FG3 07.23.2020 19607 SITE PLAN C-1.2 1 . 2 . 3 . 4 . 5 . 119 ORCUTT ROAD SINGLE STORY COMMERCIAL UNIT 12UNIT 11UNIT 10 UNIT 15UNIT 14UNIT 13 TRASH ENCLOSURE/ RECYCLING LS LS LS LS LS LS COURTYARD LS LS LS LSLSLSTRANSFORMER RAISED PLNTR PLNTR PLNTR PLNTRPLNTRPLNTRDRIVE AISLE EV READY PARKING EV READY PARKING 20.0'4'6'6.0'8.0'9.0'8.5'8.5'8.5'26.0' 26.0'24.0'7.0'10.0'26.0' UNIT 01 UNIT 02 UNIT 03 UNIT 04 UNIT 05 UNIT 06 UNIT 07 UNIT 08 UNIT 09 CONCRETE WALK CONCRETE WALKCONCRETE WALKCONCRETE WALK CONCRETE WALKCONCRETE SIDEWALKCONCRETE SIDEWALK STD CITY DRIVEWAY DRIVE AISLE DRIVE AISLE CONCRETE WALKCONCRETE WALKCONCRETE WALKLS 15.0'BUILDINGSETBACK (>20' H)10.0'BUILDINGSETBACK (<20' H)BIKE PARKING BIKE PARKING 18.5' TYP. WALL WITH WEEP HOLES AND HANDRAILS. SEE ARCHITECTURAL PLAN AND STRUCTURAL PLAN TOP OF BANK PER CITY OF SLO ORDINANCE NO. 1269 (1994 SERIES) 37 T2341S WW WWWWWG GGGGGG G GSDSDSDSDSD SDSDSDSDSDSDSSSS SSSE E E E EFWW X X X X X X X X X X X X X X X W W W W W W W W W W W W W W W W W W W WWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGGSSSSSSSSSSSSSSSSABCDEF G H I A B C D E F G H I 1 2 3 4 5 6 7 C:\Egnyte\Shared\Sun\All Jobs\2019 All Jobs\19607 - 830 Orcutt (Civil)\02_Working Drawings\Preliminary\02_ONSITE\GRADING SHEET.dwg, C-2.1, Jul 23, 2020 4:46pm, FernandoPlan Prepared By:The use of these plans and specifications shall berestricted to the original site for which they wereprepared and publication thereof is expressly limited tosuch use. Reproduction or publication by any method,in whole or in part, is prohibited. Title to these plans andspecifications remain with Ashley & Vance Engineering,Inc. without prejudice. Visual contact with these plansand specifications shall constitute prima facie evidenceof the acceptance of these restrictions.Ashley&VanceG, C1413 Monterey StreetSan Luis Obispo, CA 93401 (805) 545-0010www.ashleyvance.comC I V I L S T R U C T U R A LRevisions: Project Engineer: Project Manager: Date: AV Job No: Scale:PER PLAN Sheet Size:24" x 36" Ext: N DIAL TOLL FREE811 OR (1-800-227-2600) AT LEAST TWO DAYS BEFORE YOU DIG SITE CONSTRUCTION NOTES: CONSTRUCT ASPHALT DRIVEWAY SECTION CONSTRUCT TRASH ENCLOSURE. SEE ARCHITECTURAL PLANS CONSTRUCT 4" PCC FLATWORK. LANDSCAPING. SEE LANDSCAPE ARCHITECT PLANS INSTALL ADA PARKING AND SIGNAGE. SEE ARCHITECTURAL PLANS CONSTRUCT 0-INCH CONCRETE CURB CONSTRUCT 6-INCH CONCRETE CURB CONSTRUCT CONCRETE SITE WALL. SEE ARCHITECTURAL PLANS AND STRUCTURAL PLANS 1 2 3 4 5 6 7 8 GENERAL NOTES: SEE DEMOLITION AND PROTECTION PLAN FOR ADDITIONAL INFORMATION. ALL DEMOLITION AND GRADING SHALL BE IN COMPLIANCE WITH THE RECOMMENDATIONS CONTAINED IN THE SOILS REPORT PREPARED BY GEO SOLUTIONS , FILE NO. SL0xxxx-1, DATED xxxxxxx xx, 201x AND ALL ADDENDA TO THE REPORT SHALL BE CONSIDERED PART OF THESE PLANS. CONTRACTOR SHALL CONTACT SOILS ENGINEER PRIOR TO START OF DEMOLITION WORK. CONTACT: KRAIG R. CROZIER, PE PHONE: (805) 543-8539 RIGHT OF WAY CONSTRUCTION NOTES: CONSTRUCT 6" OF A.C. PAVING OVER 6" OF CLASS II BASE PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 2210 AND PUBLIC WORKS INSPECTOR. CONSTRUCT 20' WIDE DRIVEWAY PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 2110, 2111, 2115, 2116. CONSTRUCT 6' ATTACHED SIDEWALK PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 4110 AND 4910. REMOVE AND REPLACE EXISTING CONCRETE CURB AND GUTTER AND REPLACE WITH 6" CONCRETE CURB AND 18" GUTTER PER CITY OF SAN LUIS OBISPO STANDARD 4030. MATCH EXISTING FLOWLINE. 1 2 3 4 010 10 20 HORIZONTAL SCALE: 1" = 10' ORCUTT MIXED USE830 ORCUTT STREETSAN LUIS OBISPO, CAKBB FG3 07.23.2020 19607 GRADING AND DRAINAGE PLAN C-2.1 1 . 2 . 3 . 4 . 5 . 119 STORM DRAIN CONSTRUCTION NOTES: INSTALL ROOF DRAIN CONNECTION INSTALL 4-INCH PEDESTRIAN RATED ATRIUM GRATE DRAIN INSTALL 12-INCH TRAFFIC RATED FLAT GRATE DRAIN INSTALL STORM DRAIN MANHOLE INSTALL 4-INCH CLASS 100 PVC STORM DRAIN LINE PER MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS INSTALL 6-INCH CLASS 100 PVC STORM DRAIN LINE PER MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS SD1 SD2 SD3 SD4 SD5 SD6 STORM CHAMBERS 2600 CU FT NEW TRANSFORMER. SEE PG&E HANDOUT PACKAGE 4'TYP .4'(218.75) TC (218.2) FL MATCH (E) 220.97 FS 1 2 3 4 1 1 3 4 (218.85) ES MATCH (E) (218.33) ES MATCH (E) (219.15) TC (218.7) FL MATCH (E) (218.80) ES MATCH (E) (218.8) ES MATCH (E)(E) SANITARY SEWER (E) 12" C.I.P. WATER MAIN (E) GAS MAIN NEW UNDERGROUND ELECTRIC LINE. SEE PG&E HANDOUT SD2 SD3 SD5 SD6 1 2 5 6 7 SD1 SD1 SD1 SD1 SD1 SD1 SD1 SD2 SD2 SD3 SD4 (E) FIRE HYDRANT APPROX. 150' AWAY SD5 SD5 SD3 1 1 1 1 3 3 3 33 3 3 3 3 3 3 3 4 444 4 4 4 4 4 4 4 4 SINGLE STORY COMMERCIAL 221.0 FF BUILDING A 222.0 FF BUILDING B 222.5 FF BUILDING C 222.0 FF BUILDING A 222.5 FF BUILDING A 221.5 FF 220.5 FS 219.0 FS 221.47 FS 221.47 FS 221.97 FS 221.97 FS 222.47 FS 222.47 FS 222.47 FS 222.47 FS (E) CURB, GUTTER, AND SIDEWALK TO REMAIN (E) CURB, GUTTER, AND SIDEWALK TO REMAIN (E) 8" SEWER MAIN 221.47 FS 221.4 FS 221.4 FS 221.9 FS 221.9 FS 222.4 FS 222.4 FS 222.4 FS 222.4 FS 222.47 FS 222.27 FS 222.24 FS 222.27 FS 222.24 FS 222.27 FS 222.24 FS 221.77 FS 221.74 FS 221.77 FS 221.74 FS 222.47 FS 222.47 FS 221.97 FS 221.97 FS 222.47 FS 222.27 FS 221.47 FS 221.47 FS 221.47 FS 221.27 FS 221.27 FS 221.24 FS 221.24 FS 221.27 FS 221.24 FS 222.24 FS 218.6 FL 218.7 FL 219.2 FS219.1 FS 219.3 FS 219.2 FS 220.9 FS MAX10%MAX2%7%2 - 1 FT. STEPS - 6" EA. LANDSCAPE WALL - SEE ARCH. PLAN 10%220.6 FS 220.97 FS 220.7 FS 220.4 TG 220.8 FS 6.8%220.4 FS MAX2%MAX 2% 220.6 FS 220.9 FG2%2%221.5 FS MAX 2% MAX 2% MAX2% MAX 2% 219.5 FS 219.4 FS 219.7 FS SS P.O.C. SS P.O.C. SS P.O.C. SS P.O.C. SS C.O. WATER P.O.C. GAS P.O.C. GAS P.O.C. GAS P.O.C. WATER P.O.C. WATER P.O.C. 221.77 FS 221.74 FS 221.97 FS 221.77 FS 221.74 FS 221.77 FS 221.73 FS 221.97 FS 221.97 FS 221.97 FS221.97 FS221.97 FS 222.27 FS 222.23 FS 222.47 FS 222.27 FS 222.24 FS 222.27 FS 222.24 FS 222.47 FS 222.47 FS 222.47 FS 222.47 FS222.47 FS 222.3 FS 222.3 FS 222.3 FS 222.3 FS 223.0 TW 217.0 FG 223.0 TW 217.0 FG 223.0 TW 219.0 FG 223.0 TW 222.5 FG 222.5 TW 219.5 FG 222.5 TW 220.0 FG WALL WITH WEEP HOLES AND HANDRAILS. SEE ARCHITECTURAL PLAN AND STRUCTURAL PLAN LANDSCAPE WALL WITH WEEP HOLES. SEE ARCHITECTURAL PLAN 220.2 FG 221.5 FS 221.6 FS 221.5 FS 221.4 TG 220.4 FS 220.2 TG 221.7 FS 221.9 FS 220.0 FG 220.0 FG NEW COMMERCIAL WATER METER AND VAULTNEW DOMESTIC WATER METER LANDSCAPE WATER METER 8 8 7 INSTALL 30 SF x 2' DEEP OF FACING CLASS RSP PER CALIFORNIA STD. SPECIFICATIONS SECTION 72 - METHOD CLASS B 220.7 IE (E) SS LATERAL TO BE ABANDONED (E) GAS LINE TO BE ABANDONED TOP OF BANK TOP OF BANK PER CITY OF SLO ORDINANCE NO. 1269 (1994 SERIES) (218.46) EG (219.0) EG (219.45) EG (211.53) EG (218.68) EG FLOOD ZONE LIMIT - ZONE X PER NATIONAL FLOOD HAZARD FIRMETTE PLAN FLOOD ZONE LIMIT - ZONE X (215.9) EG (213.7) EG (217.0) EG (214.86) EG FLOOD ZONE LIMIT - ZONE X FLOOD ZONE LIMIT - ZONE X NEW STREET LIGHT PER CITY OF SLO STD. 7910 WATER CONSTRUCTION NOTES: INSTALL 2" WATER SERVICE WITH COMMERCIAL METER PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 6210, 6110, AND 6020. SEE MECHANICAL PLANS FOR SIZE FROM METER TO BUILDING. INSTALL 2" WATER SERVICE TO MANIFOLD WITH TWO 1" METERS PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 6020, 6110, 6210 AND 6260. SEE MECHANICAL PLANS FOR SIZE FROM METER TO BUILDING. INSTALL 4" PVC FIRE LINE PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 6330, 6530 AND 6020. FIRE SPRINKLER ENGINEER TO VERIFY SERVICE SIZE PRIOR TO COMMENCEMENT OF CONSTRUCTION. INSTALL 4" FIRE DOUBLE CHECK VALVE PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 6420. EXISTING WATER METER TO BE REUSED FOR IRRIGATION PURPOSES ONLY. SEE LANDSCAPE PLAN FOR ADDITIONAL INFORMATION. INSTALL 4" PVC FIRE LINE FROM BACFLOW PREVENTER TO FIRE RISER IN BUILDING. SEE FIRE SPRINKLER PLANS AND ARCHITECTURAL PLANS. FIRE SPRINKLER RISER PER FIRE PROTECTION PLANS. CONTRACTOR TO VERIFY SERVICE SIZE WITH FIRE SPRINKLER ENGINEER PRIOR TO COMMENCEMENT OF CONSTRUCTION. INSTALL THRUST BLOCK PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 8610 AND COUNTY OF SAN LUIS OBISPO STANDARD W-1, W-1A. INSTALL FIRE HYDRANT ASSEBLY PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 6310. W1 W2 W3 W4 W5 W6 W7 W8 W9 W1W2 W5 W3 W4 W6 8 '02 SD3 6" SS PVC LATERAL 6" LANDSCAPE CURB WALL WITH WEEP HOLES AND HANDRAILS. SEE ARCHITECTURAL PLAN RW RW (E) 8" RECYCLED WATER MAIN W3 W9 220.97 FS W3 W3 W3 W3 RAISED PLANTER - SEE ARCH PLANS 220.2 FG 38