Loading...
HomeMy WebLinkAboutItem 03 - COUNCIL READING FILE_a_Project PlansAll work shall comply with the City Standard Specifications - May 2018 Edition and the City Engineering Standards - May 2018 Edition, except as amended in the specifications. 1.CONTACT "UNDERGROUND SERVICE ALERT OF NORTHERN CALIFORNIA" BY PHONE AT 8-1-1 FORTY-EIGHT (48) HOURS PRIOR TO START OF CONSTRUCTION FOR LOCATION OF POWER, TELEPHONE, OIL AND NATURAL GAS UNDERGROUND FACILITIES. 2.CONTACT THE APPROPRIATE AGENCY FOR THE LOCATION OF CABLE T.V., WATER, SEWER, DRAINAGE OR UNDERGROUND FACILITIES. 3.THE CONTRACTOR SHALL POSSESS A CLASS A LICENSE AT THE TIME OF BID OPENING AND FOR THE DURATION OF THE PROJECT. general notes: san luis obispo county, california CALLE JOAQUIN LIFT STATION REPLACEMENT APPROVED BY SPECIFICATION NO.DATE of SHEET Matthew A. Horn, City Engineer R.C.E. C63611 Approved Date 56DECEMBER 2020 91133 1FILE NO./LOCATION [MO DAY, YEAR] 0 2000 40001000 SCALE 1 INCH = 2000 FEET N G-001 Know what's below. Call before you dig.CALLE JOAQUINLOS PALOSCONTENTAMIRADOR LOSVERDESVI S T A HIGHWAY 101LOSV A L L E YOSOS RO A D SAN LUIS OBISPO AND VICINITY MAP LOCATION MAP SCALE: 1" = 2000' SCALE: 1" = 250' N index to plans DescriptionSht. No. Sht. Title 1 G-001 COVER SHEET 2 G-002 SHEET LAYOUT 3 G-003 LEGEND, ABBREVIATIONS AND NOTES 4 G-004 SURVEY CONTROL DATA AND TEMPORARY CONSTRUCTION EASEMENTS 5 C-101 HIGHWAY 101 CROSSING - PLAN AND PROFILE: STA. 1+00 to 6+25 6 C-102 INVERTED SIPHON CREEEK CROSSING - PLAN AND PROFILE: STA. 6+25 to 11+00 7 C-103 CALLE JOAQUIN GRAVITY SEWER - PLAN AND PROFILE: STA. 100+00 to 104+00 8 C-104 CALLE JOAQUIN GRAVITY SEWER - PLAN AND PROFILE: STA. 104+00 to 108+00 9 C-105 CALLE JOAQUIN GRAVITY SEWER - PLAN AND PROFILE: STA. 108+00 to 111+25 10 C-200 CALLE JOAQUIN LIFT STATION - DEMOLITION PLAN 11 C-201 CALLE JOAQUIN LIFT STATION - SITE AND GRADING PLAN 12 C-202 CALLE JOAQUIN LIFT STATION - UTILITY PLAN 13 C-203 CALLE JOAQUIN LIFT STATION AND APPROACH MANHOLE DETAILS 14 C-204 CALLE JOAQUIN LIFT STATION - SECTIONS AND DETAILS 15 C-205 CALLE JOAQUIN LIFT STATION - GRADING SECTIONS AND DETAILS 16 C-501 CIVIL DETAILS - 1 17 C-502 CIVIL DETAILS - 2 18 C-503 CIVIL DETAILS - 3 19 C-504 CIVIL DETAILS - 4 20 C-505 CIVIL DETAILS - 5 21 C-506 CIVIL DETAILS - 6 22 C-507 CIVIL DETAILS - 7 23 R-101 EXISTING TOPOGRAPHY PLAN 24 R-102 EXISTING TOPOGRAPHY PROFILE 25 R-103 GRADING PLAN - FINAL 26 R-104 GRADING PROFILE 27 R-105 GRADING CROSS SECTIONS - 1 28 R-106 GRADING CROSS SECTIONS - 2 29 R-107 GRADING CROSS SECTIONS - 3 30 R-108 DETAILS - ROOTWAD 31 L-101 PLANTING PLAN 32 L-102 INVASIVE SPECIES REMOVAL AND EROSION CONTROL PLAN 33 L-103 IRRIGATION PLAN 34 L-104 MISCELLANEOUS DETAILS 35 L-105 IRRIGATION DETAILS 36 L-106 EROSION CONTROL DETAILS 37 L-107 EROSION CONTROL DETAILS 38 S-101 PUMP STATION STRUCTURE AND WALL LAYOUT PLAN 39 S-102 WALL PROFILE AND DETAIL 40 S-103 WALL SECTIONS 41 S-104 CONCRETE SLAB PLAN 42 S-501 STRUCTURAL DETAILS - 1 43 S-502 STRUCTURAL DETAILS - 2 44 S-503 STRUCTURAL DETAILS - 3 45 S-504 SPECIAL INSPECTION 46 E-101 ELECTRICAL LEGEND AND ABBREVIATIONS 47 E-102 SINGLE LINE DIAGRAMS AND ELEVATION 48 E-103 CALLE JOAQUIN LIFT STATION - ELECTRICAL SITE PLAN 49 E-104 GROUNDING PLAN, PANEL AND CONDUIT SCHEDULES 50 E-105 CONTROL SCHEMATIC DIAGRAMS 51 E-106 ELECTRICAL DETAILS 52 E-107 ELECTRICAL DETAILS 53 N-001 INSTRUMENTATION LEGEND AND SYMBOLS 54 N-002 COMMUNICTION BLOCK DIAGRAM 55 N-003 CALLE JOAQUIN LIFT STATION P&ID 56 N-004 INSTRUMENTATION DETAILS GG1wE GVICV COMGAS FO GM V-CNTL- S ( SY M BO L ) V-BLRD - S C V-COM M - S ( S Y M B O L ) V-FIBR-S ( S Y M B O L ) ICV w w w wwww w w w w w wGGS1SST CTV E CO TEL TP WMGVICVWV SCOMGASCTVTEL FO TSB G RWVM V-CNT L - T ( T E X T ) V-CNTL- S ( SY M BO L ) V-D+E (M A R K E R ) V-BLRD - S C V-COM M - S ( S Y M B O L ) V-CATV ( B L O C K & C T V ) V-WAT R - S ( S Y M B O L ) V-FLV-FLV-FIBR-S ( S Y M B O L ) V-D+E ( T EX T )SS108 110ICV rwSD 1 0 6 . 2 0 ' TOPHDWA L LCOR=106 .24 'TOPHDWALLCOR=106 .40 'TOP HD WALL 1 . 0 = 10 6 . 4 0 ' T O P H D W A L L 1 . 0 =100.11 'FL CRK=GUYGUYGUYWVSCOV-ELEV 5313 SET 5RBRWG5 31 7103 . 79 SET5RBR58 79 106 .58SET5RBR58 80 106 .58FL 3 .5D IACONC603396.046041FL 3 . 2D IACONC614694 .4 7 617 1 C 1 /2 "RBR39 84 100 .00 49 18 491 9 4 92 0 49 21 4922 49 2349244925 FL= 1 0 9 . 7 6FL= 110 . 5 4FL=1 1 1 .4 9 WVC-20 0 C-20 1 C-20 2 C-101C-103 C-104 C-105 HIGHWAY 101 CALLE JOAQUIN LOS OS OS VALLEY R OA D LIFT STATION GRAVITY SEWER CREEK CROSSING HWY 101 CROSSING FORCE MAIN C-01 C-03 L-10 1 SITE ACCESS (NOTE 1)FROOM CREEKSAN L UI S O BI S P O C R E E K SAN LUIS OBISPO CREEKPERFUMO CREEKC-102CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56N010020050 SCALE 1 INCH = 100 FEET DC NR - - SEE DWG SHEET LAYOUT2 G-002 Know what's below. Call before you dig. CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 G3 SD SD OH G SS w T C E E GM JP PP TP WM GV ICV EM PP FO TSB AVV IRR B-1 C-1 OIL E WM10 AR1 RW 1 1 ELEC MW CO TEL G S GAS SLB FO G SS12 DC NR - - SEE DWG LEGEND, ABBREVIATIONS AND NOTES3 Know what's below. Call before you dig. G-003 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG SURVEY CONTROL DATA4 G-004Know what's below. Call before you dig. TEL B O X CTVUTL V L T S4" DBL CHK VLV10" D B L C H K V L V S0.5" CONDUITSSMH #4634(16-H-17)RIM=105.03INV=93.15SSSMH #2829RIM=104.70INV=94.09SCALLE JOAQU IN STATE H IGHWAY 101 (SOUTH BOUND )STATE HIGHWAY 101(NORTH BOUND)LOS OSOS VALLEY ROAD OFFRAMPSTATE H IGHWAY 101 (NORTH BOUND )G1G2G2G2G2G2OHOHOHOHOHTTTOIL6OIL6OIL6OIL6OIL6SD48SD48OIL8OIL8OIL8OIL8OIL8OIL8OIL8OIL8SS8VCWM12WM12G2SS10VCP EEW W8W8TTE ESS10VCPSS12SS12SS12SS12SS12SS12SS12SS12SS12RW FM E 1+00 2+00 3+00 4+00 5+00 6+00 1CALTRANS RW S41° 26' 04.37"E' 3 3 5 10 20 4010 SCALE 1 INCH = 20 FEETREFER TO C-102MATCHLINE AT STA 6+250 0 20'40' H: 1" = 20' 5'10' V: 1" = 5' 100 110 1+00 2+00 3+00 4+00 80 90 120 6+005+00 70 100 110 80 90 120 70 1 3 SEWER MANHOLE - CONTROL* SSMH #NORTHING EASTING WET WELL 2285455.93 5760397.56 APPROACH MH 2285429.06 5760422.82 SSMH A 2285418.11 5760437.80 SSMH B 2285108.27 5760711.49 5 A NCITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 C-101 Know what's below. Call before you dig. DC NR SEE DWG HIGHWAY 101 CROSSING - PLAN AND PROFILE: STA. 1+00 TO 6+255REFER TO C-102MATCHLINE AT STA 6+25 SS10210210110098968885878585858890909192927+00 8+00 9+00 10+00 10+54 SS12SS12SS12SS12SS12SS12SS12SS12SS10VCPSS10VCPSS 8 V C SS 8 V C 2 SAN LU ISOBISPO CREEK 0 20 4010 SCALE 1 INCH = 20 FEETNREFER TO C-101MATCHLINE AT STA 6+250 0 20'40' H: 1" = 20' 5'10' V: 1" = 5' 100 110 100 110 80 90 80 90 70 60 70 60 6+00 7+00 8+00 9+00 10+00 11+00 5 SEWER MANHOLE - CONTROL* SSMH #NORTHING EASTING SSMH C 2284925.10 5760872.96 3 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 C-102 Know what's below. Call before you dig. DC NR SEE DWG INVERTED SIPHON CREEK CROSSING - PLAN AND PROFILE: STA. 6+25 TO 11+006REFER TO C-101MATCHLINE AT STA 6+25 STA:100+12.50SSMH #1RIM=109.88INV 8" IN=97.10INV 8" OUT=95.80STA:103+66.56SSMH #2RIM=106.29INV 8" IN=94.03INV 8" OUT=93.93INV 6" IN: 97.05EXISTING GROUND OVER SEWER PIPESTA. 101+22.77STA. 101+28.8720 LF 16" STEEL CASING12" MIN.CLEARANCEINV. = 98.90± (CALC.) STUB AND CAP FOR FUTURE 1 C-502 5LF OF 8" HDPE S=0.006 (E) 6'x7' R.C.B. S=0.0050 349.1LF OF 8" DR17 HDPE PIPE 31.0LF OF 8" DR17 HDPE PIPE S=0.0051 1 1 3 100 + 0 0 100 + 0 0 101+0 0 102+00 103+00 104+0 0 C1 L1 SG2 G2 G2 G2 G2 G2 G2 G2 G2 G2 SS6VCSS8VC SS8V C SS8VC SS8VC SS8VC SS8VC SS8VC OH OH OH OH OH OH OH OH OH OH OH OH OH OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 WM1 2 WM1 2 WM12 WM12 WM12 WM12 WM12 WM12 W8S1 0 6 . 2 0 ' T O P H DW A L L C O R = 1 0 6 . 2 4 ' T O P H DW A L L C O R = 1 0 6 . 4 0 ' T O P H D W A L L 1 . 0 = 1 0 6 . 4 0 ' TOP HD WA L L 1 . 0 = 1 0 0 . 1 1 ' F L C R K = 3 - 8 " MW L LW T O P 8 " S T E E L S S 1 0 2 . 4 0 G U Y G U Y G U Y 2 - 1 2 " MW L LW 1 8 " W L LW 6 " , 2 - 1 2 " MW L LW 8 " W L LW 1 8 " W L LW 2 - 1 8 " W L LW 6 " , 3 - 1 2 " , 1 8 " MW L LW 1 8 " W L LW 1 2 " W L LW 1 2 " W L LW 1 2 " W L LW 1 8 " W L LW 2 - 1 2 " MW L LW 3 - 1 8 " MW L LW 2 - 8 " MW L LW 2 - 1 2 " MW L LW 1 8 " W L LW 2 - 1 2 " , 1 8 " MW L LW 2 4 " W L LW 2 - 1 2 " , 1 8 " MW L LW 2 - 1 2 " MW L LW 8 " O A K 2 - 1 2 " MW L LW 3 - 3 6 " MW L LW 1 8 " W L LW 2 - 1 2 " MW L LW 2 - 1 2 " 3 - 1 8 " MW L LW 6 " W L LW 6 " 8 " MW L LW 1 8 " W L LW 1 2 " W L LW 2 - 6 " MW L LW 3 - 1 2 " MW L LW 6 " W L LW 6 " W L LW J PWV JP SSS M H # 8 3 1 4 (18- H - 1 8 ) RI M = 1 0 8 . 4 3 IN V = 9 6 . 8 0 BO R E HO L E PAI N T EL- 1 0 9 . 7 4 COCON C C H A N N E L 2 - 2 4 " MW L LW 6 1 7 1 4 9 2 0 4 9 2 1 4 9 2 2 4 9 2 3 4 9 2 4 J PWV G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 SS6VCSS8VC SS8V C SS8VC SS8VC SS8VC SS8VC SS8VC OH OH OH OH OH OH OH OH OH OH OH OH OH OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 WM1 2 WM1 2 WM12 WM12 WM12 WM12 WM12 WM12 W8STA. 103+66.56 SSMH #2 STUB FOR FUTURE CONSTRUCTION L2 S S 7.17'5.87'1 C-502 8 2 3 4 1 8 2 2 2 STA. 100+12.50 SSMH #1 CONNECT TO EXISTING 6" SS 1 CURVE TABLE CURVE # C1 RADIUS 432.70 LENGTH 354.06 EXTERNAL TANGENT 187.62 DELTA 46.8826° INV OUT=95.80 8"Ø SS INV IN=97.05 EXIST 6"Ø SS INV IN=97.10 8"Ø SS EX. 6"SS PLUG, CAP AND ABANDON PER2'2 INV OUT=93.93 8"Ø SS INV IN=94.03 8"Ø SS LINE TABLE LINE # L1 L2 LENGTH 12.50 267.66 DIRECTION N61° 13' 17.09"E N15° 36' 36.34"E 0 20 4010 SCALE 1 INCH = 20 FEETREFER TO C-104MATCHLINE AT STA 104+00 CONSTRUCTION NOTES: FURNISH AND INSTALL NEW 4' DIAMETER SEWER MANHOLE PER ENGINEERING STD 6610. COAT INTERIOR OF MANHOLE PER SPECIFICATION SECTION 099720, AND COAT OUTSIDE PER SPECIFICATION SECTION 034210. ABANDON EXISTING SEWER PER ENGINEERING STD 6050 INSTALL 16" STEEL CASING UNDER EXISTING 6'x7' REINFORCED CONCRETE BOX CULVERT PER DETAIL 8"Ø DR17 HDPE SEWER PIPE PER SPECIFICATION SECTION 402097 AND ENGINEERING STD 6020 ABANDON EXISTING MANHOLE PER ENGINEERING STD 6050. UNDERGROUND UTILITY LOCATIONS ARE PLOTTED BASED ON ABOVE GROUND PAINT MARKS BY OTHERS, ABOVE GROUND SURFACE STRUCTURES. ACTUAL LOCATION MAY DIFFER. ADDITIONAL UNDERGROUND UTILITY LINES MAY EXIST. FOR INFORMATION REGARDING UTILITY LOCATION, SIZE, DEPTH, CONDITION, AND CAPACITY CONTACT UTILITY OR MUNICIPAL/PUBLIC SERVICE FACILITY. UNDERGROUND PIPE SIZES ARE BASED ON VISUAL OBSERVATIONS MADE FROM THE SURFACE AND ARE APPROXIMATE. EASEMENTS AFFECTING THE PROPERTY SHOWN HEREON HAVE BEEN PLOTTED BASED UPON PROVIDED TITLE INFORMATION. SEWER MANHOLE - CONTROL* SSMH #NORTHING EASTING SSMH #1 2284557.94 5760057.38 SSMH #2 2284825.22 5760274.38 *(POINT AT CENTER OF MANHOLE BASE) 3 C-502 100 110 100+00 101+00 102+00 103+00 90 120 REFER TO C-104MATCHLINE AT STA 104+000 0 20'40' H: 1" = 20' 5'10' V: 1" = 5' 104+00 80 100 110 90 120 80 MANHOLE #1 STA. 100+12.50 MANHOLE #2 STA. 103+66.56 1 2 3 4 GENERAL NOTES: SEE SHEET G-003 FOR GENERAL NOTES (TYP.) INV.=97.13 8N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN GRAVITY SEWER - PLAN AND PROFILE: STA. 100+00 to 104+007 C-103 Know what's below. Call before you dig. 9 10 119' 104+00 105+00 106+00 107+00 108+00L2L3 GG100" EUC84" EUCSSMH #3732(9-H-17)RIM=103.87INV=94.05SS105 103 102 104 100 100 104 104 1 0 3 104 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 OH OH OH OIL6SS8VCSS8VCSS8VCSS8VCSS8VCSS8VCSS8VCSS8VC OH OH OH OH OH OH OH OHOIL6OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 WM12 WM12 WM12 WM12 WM12 WM12 WM12 WM12JP GG84" EUCSSMH #3732(9-H-17)RIM=103.87INV=94.05STSBPPWITHRISERJPSGUY2-12",18" MWLLW2-12" MWLLW8" OAK2-12" MWLLW3-36" MWLLW18" WLLW6" WLLW12" 18" MWLLW6" WLLW2-18" MWLLW2-12",36" MWLLW6" WLLW2-6" 12" MWLLW12" WLLW5-12" 18" MWLLW12" WLLW12" 2-24" MWLLW2-12" MWLLW2-12" 3-18" MWLLW6" WLLWJP BOREHOLEPAINTEL-104.81531360414918491949204921G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 OH OH OH OIL6SS8VCSS8VCSS8VCSS8VCSS8VCSS8VCSS8VCSS8VC OH OH OH OH OH OH OH OHOIL6OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 WM12 WM12 WM12 WM12 WM12 WM12 WM12 WM12 STA. 106+34.22 SSMH #3 S 3 1 8 3 2 2 STA:106+34.22SSMH #3RIM=104.61INV 8" IN=92.59INV 8" OUT=92.49EXISTING GROUND OVER SEWER PIPE S=0.0051 S=0.0065 231.7LF OF 8" DR17 HDPE PIPE 163.3LF OF 8" DR17 HDPE PIPE 1 L2 L3 267.66 347.35 N15° 36' 36.34"E N15° 15' 30.08"E INV OUT=92.49 8"Ø SS INV IN=92.59 8"Ø SS LINE TABLE100 110 90 120 REFER TO C-105MATCHLINE AT STA 108+0080 REFER TO C-103MATCHLINE AT STA 104+00REFER TO C-105MATCHLINE AT STA 108+00REFER TO C-103MATCHLINE AT STA 104+00105+00 106+00 107+00 108+00 0 20 4010 SCALE 1 INCH = 20 FEET 0 0 20'40' H: 1" = 20' 5'10' V: 1" = 5' 104+00 100 110 90 120 80 CONSTRUCTION NOTES: FURNISH AND INSTALL NEW 4' DIAMETER SEWER MANHOLE PER ENGINEERING STD 6610. COAT INTERIOR OF MANHOLE PER SPECIFICATION SECTION 099720, AND COAT OUTSIDE PER SPECIFICATION SECTION 034210. ABANDON EXISTING SEWER PER ENGINEERING STD 6050 8"Ø DR17 HDPE SEWER PIPE PER SPECIFICATION SECTION 402097 AND ENGINEERING STD 6020 ABANDON EXISTING MANHOLE PER ENGINEERING STD 6050. UNDERGROUND UTILITY LOCATIONS ARE PLOTTED BASED ON ABOVE GROUND PAINT MARKS BY OTHERS, ABOVE GROUND SURFACE STRUCTURES. ACTUAL LOCATION MAY DIFFER. ADDITIONAL UNDERGROUND UTILITY LINES MAY EXIST. FOR INFORMATION REGARDING UTILITY LOCATION, SIZE, DEPTH, CONDITION, AND CAPACITY CONTACT UTILITY OR MUNICIPAL/PUBLIC SERVICE FACILITY. UNDERGROUND PIPE SIZES ARE BASED ON VISUAL OBSERVATIONS MADE FROM THE SURFACE AND ARE APPROXIMATE. EASEMENTS AFFECTING THE PROPERTY SHOWN HEREON HAVE BEEN PLOTTED BASED UPON PROVIDED TITLE INFORMATION. SEWER MANHOLE - CONTROL* SSMH #NORTHING EASTING SSMH #3 2285083.00 5760346.39 *(POINT AT CENTER OF MANHOLE BASE) MANHOLE #3 STA. 106+34.22 1 2 3 GENERAL NOTES: SEE SHEET G-003 FOR GENERAL NOTES (TYP.) 8N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN GRAVITY SEWER - PLAN AND PROFILE: STA. 104+00 to 108+008 C-104 Know what's below. Call before you dig. 9 10 11 STA:109+81.57APPROACH MHRIM:104.37STA:110+68.08SSMH #6RIM=104.53INV 12" IN=93.79INV 12" OUT=93.70STA:110+94.71EXISTING SSMH #2829RIM=104.70INV 10" IN=94.09INV 12" OUT=93.9980.4LF OF 12" DR17 HDPE PIPE (E) DBLE 5'x5' R.C.B.12" MINCLR.20 LF 16" STEEL CASING INV IN: 90.23 8" INV IN: 92.42 12" CONNECT TO EXISTING MANHOLE PER DETAIL 4 C-504S=0.0065 178.0LF OF 8" DR17 HDPE PIPE S=0.0150 S=0.0088 21.6LF OF 12" DR17 HDPE PIPE STA:111+01.39 L10.6'FORCEMAIN CONNECTIONINV=95.12±1 3 4 EXISTING GROUND OVER SEWER PIPE 8110+95108+00 109+00 110+00 L4 L5ICVWVG4 " D B L C H K V L V 10" DBL CHK VLVSWMWVWVRWVRWVWVWVWVWVS SWVG104 104 105 105 102103 104103 104 105 FMG1 G2 G2 G2 G2 G2 G2 G2 G2 G2 OH OH OH OH OH OH OH OH OH OH TSS10VCP SS10VCP OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 SD48SD48SD48SD48SS8VC SS8VC SS8VC WM12 WM12 WM12 WM12 G2G2SS10VCPW8EW8 W8 W8TESS10VCP SS12SS12RWRWFMFMEEFMG1 G2 G2 G2 G2 G2 G2 G2 G2 G2 OH OH OH OH OH OH OH OH OH OH TSS10VCP SS10VCP OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 OIL6 SD48SD48SD48SD48SS8VC SS8VC SS8VC WM12 WM12 WM12 WM12 G2G2SS10VCPW8EW8 W8 W8TESS10VCP SS12SS12RWRWFMFMEESTA. 109+94.63 APPROACH MH STA. 110+78.62 SSMH #610911011 0 4 C-504 12"Ø HDPE SS IN 30"Ø STEEL CASING, SEE SHEET C-101 ABANDON EXISTING SEWER PER ENGINEERING STD 6050 S S 4 6 2 5 1 5 7 2 7 3 8 27.31'34.53'CONNECT NEW 12"Ø HDPE TO EXISTING MH PER DETAIL L3 INV IN=92.42 INV DROP INLET =85.73 12"Ø SS INV IN=89.93 INV DROP INLET=86.06 8"Ø SS INV IN=85.73 12"Ø SS INV OUT=85.68 12"Ø SS INV IN=93.79 12"Ø SS INV OUT=93.70 12"Ø SS L3 L4 L5 347.35 86.51 26.63 N15° 15' 30.08"E N22° 15' 34.76"E N36° 26' 48.06"W LINE TABLE 100 110 90 120 80 REFER TO C-104MATCHLINE AT STA 108+00REFER TO C-104MATCHLINE AT STA 108+00109+00 110+00 111+00 112+00 0 20 4010 SCALE 1 INCH = 20 FEET 0 0 20'40' H: 1" = 20' 5'10' V: 1" = 5' 108+00 100 110 90 120 80 CONSTRUCTION NOTES: FURNISH AND INSTALL NEW 4' DIAMETER SEWER MANHOLE PER ENGINEERING STD 6610. COAT INTERIOR OF MANHOLE PER SPECIFICATION SECTION 099720, AND COAT OUTSIDE PER SPECIFICATION SECTION 034210. ABANDON EXISTING SEWER PER ENGINEERING STD 6050 FURNISH AND INSTALL NEW 6' DIAMETER APPROACH MANHOLE PER DETAIL COAT INTERIOR OF MANHOLE PER SPECIFICATION SECTION 099720, AND COAT OUTSIDE PER SPECIFICATION SECTION 034210 JACK AND BORE 16" STEEL CASING UNDER EXISTING DOUBLE 5''x5' REINFORCED CONCRETE BOX CULVERT PER DETAIL 12"Ø DR17 HDPE SEWER PIPE PER SPECIFICATION SECTION 402097 AND ENGINEERING STD. 6020 8"Ø DR17 HDPE SEWER PIPE PER SPECIFICATION SECTION 402097 AND ENGINEERING STD 6020 10"Ø DR17 HDPE SEWER FORCE MAIN, SEE SHEET C-202 ABANDON EXISTING MANHOLE PER ENGINEERING STD 6050 UNDERGROUND UTILITY LOCATIONS ARE PLOTTED BASED ON ABOVE GROUND PAINT MARKS BY OTHERS, ABOVE GROUND SURFACE STRUCTURES. ACTUAL LOCATION MAY DIFFER. ADDITIONAL UNDERGROUND UTILITY LINES MAY EXIST. FOR INFORMATION REGARDING UTILITY LOCATION, SIZE, DEPTH, CONDITION, AND CAPACITY CONTACT UTILITY OR MUNICIPAL/PUBLIC SERVICE FACILITY. UNDERGROUND PIPE SIZES ARE BASED ON VISUAL OBSERVATIONS MADE FROM THE SURFACE AND ARE APPROXIMATE. EASEMENTS AFFECTING THE PROPERTY SHOWN HEREON HAVE BEEN PLOTTED BASED UPON PROVIDED TITLE INFORMATION. SEWER MANHOLE - CONTROL* SSMH #NORTHING EASTING Approach MH 2285429.06 5760422.82 SSMH #6 2285498.17 5760470.57 *(POINT AT CENTER OF MANHOLE BASE) 3 C-502 1 C-505 APPROACH MH STA. 109+91.94 MANHOLE #6 STA. 110+78.62 1 2 3 GENERAL NOTES: SEE SHEET G-003 FOR GENERAL NOTES (TYP.) 4 5 6 7 8N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN GRAVITY SEWER - PLAN AND PROFILE: STA. 108+00 to 111+259 C-105 Know what's below. Call before you dig. 9 10 11NN ICV WV LAWN TEL B O X CTVUT L V L T EBOXJP UTL VLT4" DB L C H K V L V 10" DBL C H K V L V SSMH #4785 RIM=105.20 BOT=83.5 TOP INV. SIPHON PIPE=88.45 INV PIPE FROM MH STREET=91.50 (13.7' DOWN ON SLOPE) S EBOX 0.5" ELE RSR 2" ELE RSR AND E PANELS 1" EL E R S R PP ELE STL POST 0.5" CONDUIT WMWV WV SSMH #4634(16-H-17)RIM=105.03INV=93.152" GAS1" G A S TOP 48" CMP = 100.56 FL 48" CMP = 96.45 ICVICVRWVRWVWVWVWV WV S SSMH #2829 RIM=104.70 INV=94.09 S CO BH-+/- APPRX. AC AC AC CITY SLO SEWER EASEMENT APN: 053-171-034 PORTION PARCEL 1 37/PM/29 BHG PROPERTY LLC & GJB REMAINDER LLC CA L L E JO AQU IN CITY S L O D R AI N A G E 30' DR A I N A G E EASEM E N T #39 FD 1" IP LS 3673 #392 FD BC LS 8206 APN: 053- 171 - 033 APN: 053-171-032 CITY OF SLO EASEMENT PARCELPER DOC#2008043363SLB 390 393 1 0 4 1031041051 0 7 10610 6 105 W G2FMFMFMW FM G1 G1 G1 G1 G1 G1G1G2G2G2G2G2G2G2G2OHOHOHOHOHOHOHOHOHOHT T T T T T T T T T SS10VCPOIL6OIL6OIL6OIL6OIL6OIL6OIL6OIL6OIL6SD48SD48SD48SD48SD48SD48SD48SD48SD48SS8VCSS8VCWM12WM12WM12WM12SS SS SS SS SS SS SS SS SS G2G2G2SS10VCPW8RW W W E E E E E E E E W W W W W W W W W8W8W8W8W8W8W8WWWT T T T T T T T T E E E E E E E E SS10VCP SS10VCPSS10VCPSS10VCPSS12SS12SS12RWRWRWRWFMFMEEEE1SITE DEMOLITION PLAN 0 10 205 SCALE 1 INCH = 10 FEET DEMOLITION NOTES ITEM DESCRIPTION NOTES: LEGEND: N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN LIFT STATION - DEMOLITION PLAN10 C-200 SS Know what's below. Call before you dig. W G1 105 106107 108109110110 109 104 ICV WV TEL B O X CTVJP UTL VLTELEWM WV SSMH #4634(16-H-17)RIM=105.03INV=93.15RWVRWVWVWVWV WV SLB 1041 0 7 10 6 105 A C-2 0 4BC-204CALLE JOAQUINC C-204 1SITE AND GRADING PLAN 0 10 205 SCALE 1 INCH = 10 FEET 14 10 2 1 2 CONSTRUCTION NOTES: 3 1 2 N 2 1 NOTES: 1 1 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN LIFT STATION - SITE AND GRADING PLAN11 C-201 Know what's below. Call before you dig. LEGEND: ICV WV TEL B O X CTVUT L V L T UTL VLT4" DB L C H K V L V 10" DBL C H K V L V 0.5" CONDUIT WMWV WV SSMH #4634(16-H-17)RIM=105.03INV=93.15TOP 48" CMP = 100.56 FL 48" CMP = 96.45 RWVRWVWVWVWV WV SSMH #2829 RIM=104.70 INV=94.09 BH-+/- APPRX. 390 393 W G2W G1 G1 G1G1G2G2G2G2G2G2G2G2OHOHOHOHOHOHOHOHOHOHT T T T T T T T T T SS10VCPOIL6OIL6OIL6OIL6OIL6OIL6OIL6OIL6OIL6SD48SD48SD48SD48SD48SD48SD48SD48SD48SS8VCSS8VCWM12WM12WM12WM12SS SS SS SS SS G2G2G2SS10VCPW8RW W W E E E E E E E E W W W W W W W W W8W8W8W8W8W8W8WWWT T T T T T T T T E E E E E E E E SS10VCP RWRWRWRWEEEEBG1W4 W4 W4 W4 G1 G1 G1 G1 G1 G1 ACG1G1G1 G1 G1 G1 G1 G1 1 1UTILITY PLAN 0 10 205 SCALE 1 INCH = 10 FEET 1 4 1 CONSTRUCTION NOTES: NOTES: 2 N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN LIFT STATION - UTILITY PLAN12 C-202 Know what's below. Call before you dig. 1 72" APPROACH MANHOLE 1 2 AFRP LIFT STATION MATERIALS LIST 1 2 4 NOTES: CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN LIFT STATION AND APPROACH MANHOLE DETAILS13 C-203 Know what's below. Call before you dig. 2CAST-IN-PLACE MANHOLE BASE CONT'D CONT'DCSECTION BSECTION MATERIALS LIST 2 2 NOTES: CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN LIFT STATION AND APPROACH MANHOLE DETAILS14 C-204 Know what's below. Call before you dig. 1 2 1 ASECTION BSECTION CSECTION CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CALLE JOAQUIN LIFT STATION - GRADING SECTIONS AND DETAILS15 C-205 NOTE: Know what's below. Call before you dig. TYPICAL UTILITY CROSSING SECTION 3 A PIPE SUPPORT 2 TYPICAL THRUST BLOCKS 4 PLAN (TYPE-1)PLAN (TYPE-2)PLAN (TYPE-3, HORIZ BEND) ELEV (TYPE-4, VERT BEND)SECTION ENCASED DOUBLE BARREL SIPHON SECTION 5 VALVE BOX DETAIL 1 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CIVIL DETAILS - 116 C-501 Know what's below. Call before you dig. STUB AND CAP FOR FUTURE 1 JACKED CASING DETAIL 3 CASING SECTION B METER VAULT 2 A 5 PRECAST CONCRETE SECTION A 2 N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CIVIL DETAILS - 217 C-502 Know what's below. Call before you dig. CENTER GATE STOP 3 1DOUBLE LEAF GATE DETAIL POST & MATERIALS TABLE TYPICAL FENCE ELEVATION 2 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR - - SEE DWG CIVIL DETAILS - 318 C-503 Know what's below. Call before you dig. 1DETAIL STA 8+50.42 2DETAIL A STA 6+06.43 6 NN55 STA 10+32.89 3DETAIL EXISTING FINAL NSTA 111+05.25 4DETAIL EXISTING FINAL N ASECTION 5 5DETAIL Know what's below. Call before you dig. CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 5619 C-504 DC NR SEE DWG CIVIL DETAILS - 4 1GENERATOR NATURAL GAS CONNECTION 210" RESTRAINED TRANSITION COUPLER NOTES: 1.COUPLER TO BE ISCO ISMFJ1017IPSBELL OR APPROVED EQUAL NOTES: 1.COUPLER TO BE ISCO ISMFJ1017IPSBELL OR APPROVED EQUAL 3ODOR CONTROL UNIT DETAIL 4TYPICAL QUICK COUPLER DETAIL 5TYPICAL WALL PENETRATION 6STOP PLATE GUIDE CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 Know what's below. Call before you dig. 20 C-505 DC NR SEE DWG CIVIL DETAILS - 5 G1 G1 G1 T T T T T T T T T T SS SS SS E E E E E E E E E E T T T T T T T T T T G1 G1 A 1CONNECTION AT EXISTING SEWER LATERAL MATERIALS LIST NOTES: 2VALVE VAULT AVALVE VAULT SECTION N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG CIVIL DETAILS - 621 C-506 Know what's below. Call before you dig.N A 1WET WELL MATERIALS LIST NOTES: AWET WELL SECTION CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG CIVIL DETAILS - 722 C-507 Know what's below. Call before you dig.N1 SSS9090 9 0 90 90 909090 909090909090 100100 100888888888 8 88 88 8888 88 92 9292 92 92 92 9 2 92929294949494 94 94 94 94949 4 96 96 9 6 96 9696969 6 989898 9 898 10 2 102 102 1 0 2 1 0 2 10 41041061 0 6 1081 0 8 EXISTING 12" SEWER 0+00 1+002+00 3+004 + 0 0 5+006+006+360+50 1+50 2+50 3+50 4+505+50APPROX. EXISTING CONCRETE ENCASEMENT DOWNSTREAM POOL UPSTREAM POOL DOWNSTREAM RIFFLE UPSTREAM RIFFLE H I G HW A Y 1 0 1 O F F - R A M P CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O R NIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELYPLAN - EXISTING TOPOGRAPHY SCALE 1"=10'-0" OL GR SM - 1"=10'-0"EXISTING TOPOGRAPHY PLAN23 R-101 0 10 205 SCALE 1 INCH = 10 FEETN CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O R NIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELY0 0 10'20' H: 1" = 10' 10'20' V: 1" = 1' APPROX. EXISTING SURFACE DOWNSTREAM RIFFLE APPROX. EXISTING CONCRETE ENCASEMENT EXISTING 12" SEWER PROFILE - EXISTING SCALE 1"=10'-0" APPROX. LOW FLOW WATER SURFACE DOWNSTREAM POOL UPSTREAM POOL UPSTREAM RIFFLE STA 0+25.27ELEV 84.74STA 1+46.77ELEV 86.45OL NR SM - SEE DWG EXISTING TOPOGRAPHY PROFILE24 R-102 &GB'S OR 50' INTERVALSSS9090 9 0 90 90 909090 909090909090 100100 100888888888 8 88 88 8888 88 92 9292 92 92 92 9 2 92929294949494 94 94 94 94949 4 96 96 9 6 96 9696969 6 989898 9 898 10 2 102 102 1 0 2 1 0 2 10 41041061 0 6 1081 0 8 APPROX. EXTENT OF GRADING (TO BE DESIGNED BY CONTRACTOR) DOWNSTREAM RIFFLE MECHANICAL INVASIVE PLANT REMOVAL AREA. REMOVE ACCUMULATED SEDIMENT AT BASE OF VEGETATION. REGRADE TO MATCH EXISTING CHANNEL BANKS UPSTREAM AND DOWNSTREAM (TO BE SUPERVISED BY CITY REP). 0+00 1+002+00 3+00 4 + 0 0 5+006+006+360+50 1+50 2+50 3+50 4+505+50H I G HW A Y 1 0 1 O F F - R A M P CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O R NIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELY0 10 205 SCALE 1 INCH = 10 FEETNB C-05 A C-05 PLAN - GRADING - FINAL SCALE 1"=10'-0" NEW 2x6" SEWER EXCAVATE TRENCH FOR INSTALLATION OF NEW PIPE AND REMOVAL OF EXISITNG PIPE (TO BE DESIGNED BY CONTRACTOR) APPROX. EXISTING CONCRETE ENCASEMENT TO BE REMOVED LOG WITH ROOTWAD. SEE SHEET 48 TRENCH APPROX. 80' WIDE x 16' DEEP x 450' LONG (TO BE DESIGNED BY CONTRACTOR) NEW JOINED POOL UPSTREAM RIFFLE REMOVE (E) PIPE LOG WITH ROOTWAD. SEE SHEET 48 OL NR SM - 1" = 10'-0"GRADING PLAN - FINAL25 R-103 C C-06 D C-06 E C-07 F C-07 APPROX. DOWNSTREAM END OF DEWATERING/BYPASS SYSTEM. TO BE CONFIRMED ON SITE. APPROX. UPSTREAM END OF DEWATERING/BYPASS SYSTEM. TO BE CONFIRMED ON SITE. NOTE: EXISTING PIPE TO BE STABILIZED IN PLACE DURING EXCAVATION OF TRENCH AND INSTALLATION OF NEW SEWER. LEGEND: LOG WITH ROOTWAD CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O R NIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELY0 0 10'20' H: 1" = 10' 10'20' V: 1" = 1' APPROX. FINISHED SURFACE DOWNSTREAM RIFFLE CREST NEW 2x6" SEWER PROFILE - GRADING - FG SCALE 1"=10'-0" APPROX. LIMITS OF GRADING OF TRENCH FOR INSTALLATION OF NEW SEWER. (TO BE DESIGNED BY CONTRACTOR) APPROX. EXISTING SURFACE APPROX. EXISTING CONCRETE ENCASEMENT STA: 2+32.41 ELEV: 86.75 2H :1V 2H :1V EXISTING SEWER TO BE REMOVED APPROX. LOW FLOW WATER SURFACE. OL NR SM - SEE DWG GRADING PROFILE26 R-104 STA: 1+10.91 ELEV: 84.74 NOTE: EXISTING PIPE TO BE STABILIZED IN PLACE DURING EXCAVATION OF TRENCH AND INSTALLATION OF NEW SEWER. CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O R NIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELY0 0 10'20' H: 1" = 10' 10'20' V: 1" = 1' APPROX. EXISTING SURFACE APPROX. EXISTING SURFACE A CROSS SECTION VIEW STA 10+10 - FG -SCALE 1"=10'-0" B CROSS SECTION VIEW STA 10+00 - FG -SCALE 1"=10'-0" LIMIT OF TRENCH (TO BE DESIGNED BY CONTRACTOR) PROVIDE EROSION PROTECTION ALONG THE LENGTH OF EXCAVATION (SEE PLANTING PLAN) TRENCH FOR INSTALLATION OF NEW SEWER. (TO BE DESIGNED BY CONTRACTOR) NEW 2x6" SEWER CROSSING BASE OF INSTALLATION TRENCH FINISHED SURFACE TO MATCH EXISTING SURFACE NOTES: 1.REMOVE EXISTING PIPE AT LEAST 6-FEET IN FROM TOE OF BANK, EITHER BY PULLING A SEGMENT OR TRENCHING, CUTTING AND BACKFILLING. REMOVE PIPE (EXTENT TO BE SHOWN ON TRENCH DESIGN BY CONTRACTOR) PROVIDE EROSION PROTECTION ALONG LENGTH OF EXCAVATION ELEVATION OF PIPE TO BE CONFIRMED IN FIELD APPROX. FINISHED SURFACE LIMIT OF TRENCH (TO BE DESIGNED BY CONTRACTOR) REMOVE PIPE (EXTENT TO BE SHOWN ON TRENCH DESIGN BY CONTRACTOR) PROVIDE EROSION PROTECTION (SEE PLANTING PLAN) PROVIDE EROSION PROTECTION (SEE PLANTING PLAN) OL NR SM - SEE DWG GRADING CROSS SECTIONS - 1 OF 327 R-105 NOTE: EXISTING PIPE TO BE STABILIZED IN PLACE DURING EXCAVATION OF TRENCH AND INSTALLATION OF NEW SEWER. EXISTING GRADE LEFT BANK RIGHT BANK 3H:1V 10H:1V EXISTING GRADE LEFT BANK RIGHT BANK 3H:1V 10H:1V CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O R NIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELYOL NR SM - 1" = 10'-0"GRADING CROSS SECTIONS - 2 OF 328 R-106 C CROSS SECTION VIEW STA 3+69 - FG -SCALE: H 1"=15'-0" D CROSS SECTION VIEW STA 4+20 - FG -SCALE: H 1"=15'-0" NOTES: 1.GRADING SLOPES ARE INDICATIVE TO SHOW REMOVAL OF ACCUMULATED SEDIMENT AT THE BASE OF INVASIVE VEGETATION (TO BE REMOVED). WHERE ACCUMULATED SEDIMENT IS FOUND WIHTIN THE VEGETATION CLEARING ZONE, GRADE BANKS AT A MAXIMUM SLOPE OF 3H:1V, MINIMUM SLOPE OF 10H:1V TO MATCH EXISTING BANK SLOPE UPSTREAM AND DOWNSTREAM. TO BE SUPERVISED BY CITY REP. V 1"=15'-0" V 1"=15'-0" 00 15'30' 1" = 15' EXISTING GRADE LEFT BANK RIGHT BANK 3H:1V 10H:1V EXISTING GRADE LEFT BANK RIGHT BANK CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O R NIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELYOL NR SM - 1" = 10'-0"GRADING CROSS SECTIONS - 3 OF 329 R-107 E CROSS SECTION VIEW STA 4+70 - FG -SCALE: H 1"=15'-0" F CROSS SECTION VIEW STA 5+26 - FG -SCALE 1"=30'-0" NOTES: 1.GRADING SLOPES ARE INDICATIVE TO SHOW REMOVAL OF ACCUMULATED SEDIMENT AT THE BASE OF INVASIVE VEGETATION (TO BE REMOVED). WHERE ACCUMULATED SEDIMENT IS FOUND WIHTIN THE VEGETATION CLEARING ZONE, GRADE BANKS AT A MAXIMUM SLOPE OF 3H:1V, MINIMUM SLOPE OF 10H:1V TO MATCH EXISTING BANK SLOPE UPSTREAM AND DOWNSTREAM. TO BE SUPERVISED BY CITY REP. 00 15'30' 1" = 15' V 1"=15'-0" NATIVE TREE WITH ROOTWAD FLOW FINISHED GRADE BRANCHES AND FOILAGE NOT SHOWN FOR CLARITY, BUT MAY BE LEFT INTACT NOTES: 1.NATIVE TREES SHALL BE SALVAGED WITH THE ROOTWAD INTACT TO THE EXTENT POSSIBLE. 2.LIMB BRANCHES FROM ONE SIDE OF THE TREE SO THAT THS SIDE COMES INTO CLOSER CONTACT WITH THE STREAM BED. REMAINING BRANCHES AND FOLIAGE ARE NOT SHOWN FOR CLARITY, BUT MAY BE LEFT INTACT. 3.TREES WITH ROOTWADS WILL GENERALLY BE PLACED WITH THE ROOTWAD END IN THE UPSTREAM DIRECTION. FINAL POSITIONING OF TREES WITH ROOTWADS WILL BE DIRECTED BY THE CITY REPRESENTATIVE. 4.SEE TYPICAL ANCHORING DETAILS ON THIS SHEET FOR ANCHOR REQUIREMENTS REFER TO SPECIFICATION SECTION 02990 FOR THE DETAILS OF THESE REQUIREMENTS. 5.INSTALL DUCKBILL ANCHORS PER MANUFACTURERS SPECIFICATIONS. INSTALL A MINIMUM OF 2 ANCHORS PER LOG. EACH ANCHOR SHALL BE LOAD LOCKED AND TESTED USING A MANTA LL-2 ANCHOR LOCKING KIT. TESTING AND REPORTING SHALL BE AS DESCRIBED IN SPECIFICATIONS SECTION 02990. LIMB BRANCHES FROM ONE SIDE OF THE TREE SO THAT THS SIDE COMES INTO CLOSER CONTACT WITH THE STREAM BED. INSTALL ANCHORS PER MANUFACTURERS SPECS. INSTALL 2 ANCHORS PER LOG. LOAD LOCK AND TESTED USING A MANTA LL-2. (SEE SPECS SECTION 02990) CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 P R OFESSIONAL REGISTERED E N GI NEERS T ATE OF CA L IF O RNIANo. 80567 Exp. 03-31-2021 CIV I LSTEVEN A L L EN M C N EELYOL NR SM - -DETAILS - ROOTWAD30 R-108 1 ROOTWAD DETAIL -SCALE: NTS EXISTING VEGETATION EXISTING DENSE VEGETATION C A B R I L L O HW Y N O R T H B O U N D O F F R AM P S AN LU I S O B I S PO CR E E K A G R I C U L T U R A L F A R M R D AGRIULTURAL FIELD R R 1.SEED QUANTITIES PROVIDED IN PLANTING LIST ARE IN POUNDS OF PURE LIVE SEED (PLS). 2.INSTALL PLANT MATERIALS IN QUANTITIES AS SHOWN GRAPHICALLY ON DRAWINGS. 3.NO PLANT, CUTTING OR SEED SPECIES OR VARIETY CAN BE SUBSTITUTED, ALTERED OR DELETED FROM THIS PROJECT WITHOUT THE WRITTEN APPROVAL OF THE CITY REPRESENTATIVE. 4.IN ADDITION TO AREAS TO BE SEEDED WHERE INDICATED ON PLANTING PLANS, CONTRACTOR SHALL SEED ANY AREAS DISTURBED BY CONSTRUCTION, VEHICLE OR EQUIPMENT ACCESS, STAGING, MATERIAL STORAGE OR RELATED ACTIVITIES. USE NATIVE EROSION CONTROL MIX AT THE RATE OF 65 LBS OF PLS/ACRE CONSISTING OF 6 LBS VULPIA MICROSTACHYS 'THREE WEEKS FESCUE', 4 LBS TRIFOLIUM WILDENOVII 'TOMCAT CLOVER', 5 LBS NASSELA CERNUA 'NODDING NEEDLEGRASS', 10 LBS ELYMUS GLAUCUS 'BLUE WILDRYE', 5 LBS HORDEUM BRACHYANTHERUM SPP. CALIFORNICUM 'CALIFORNIA MEADOW BARLEY. SEED MIX AVAILABLE AT PACIFIC COAST SEED. WHERE SOIL IS COMPACTED OVER 80% RELATIVE COMPACTION, AND AS DETERMINED BY CITY REPRESENTATIVE, SOIL SHALL BE RIPPED OR ROTOTILLED TO THE DEPTH OF 9", RINGROLLED OR RAKED PARALLEL WITH CONTOUR AND SEED SHALL BE RAKED IN (PARALLEL W/CONTOUR). EXISTING ORGANIC DUFF AND DEBRIS SHALL BE SALVAGED AND DISTRIBUTED EVENLY OVER SEEDED AREAS ON SLOPES BETWEEN 4:1 AND 3:1 TO PROVIDE A MIN.1/2 THICK LAYER. SLOPES BETWEEN 3:1 AND 1.5:1 SHALL BE PROTECTED WITH COIR NETTING (FABRIC) OF 600gm2 (3:1 to 2:1) AND 900gm2 (2:1 to 1.5:1) WEIGHT. COIR FABRIC SHALL BE ANCHORED WITH 24" LONG, WEDGE-SHAPED STAKES CUT FROM 2X4 NPT DF WOOD, STAGGERED AT 3'-0" O.C. 5.5% OR 5 (WHICHEVER LARGER) OF CONTAINERIZED PLANTS OF EACH SPECIES SHALL BE TESTED IN THE SOURCE NURSERY FOR PHYTOPHTHORA INFESTATION. IF A PLANT OF ANY SPECIES TESTS POSITIVE FOR PHYTOPHTHORA, NO OTHER PLANTS OF THE SAME SPECIES FROM THE SAME NURSERY WILL BE ALLOWED IN THE PROJECT. PLANTS WILL BE SUBSTITUTED FROM A DIFFERENT NURSERY (AFTER TESTING THERE PROVES THEY ARE NEGATIVE FOR PHYTOPHTHORA). NO INFECTED, DISEASED OR INSECT INFESTED PLANT SHALL BE DELIVERED TO THE PROJECT AREA. 6.NURSERY PLANTS DELIVERED TO THE PROJECT AREA SHALL BE IN A THRIVING CONDITION AND SHALL SHOW NO SIGNS OF ANY NUTRIENT OR MINERAL DEFICIENCIES. 7.PLANTS SHALL BE IN THRIVING CONDITION BOTH AT THE TIME OF DELIVERY TO THE SITE AND DURING THE FINAL PLANT INSTALLATION ACCEPTANCE INSPECTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THEIR PROTECTION AND ALL NECESSARY MAINTENANCE, INCLUDING TEMPORARY IRRIGATION BETWEEN PLANT DELIVERY TO THE PROJECT AREA AND INSTALLATION ACCEPTANCE INSPECTION. WATER SURFACE (BASE FLOW) RESTORATION SIGNRR 30 601500 SCALE 1 INCH = 30 FEETN PLANTING PLANPLANTING SCHEDULE SEED MIXES NOTES LEGEND GS CM GS DSC CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 7 L- 4 7 L- 4 AT 34" X 22" DRAWING SIZE SCALE ACCORDINGLY IF REDUCED L-101 31 C A B R I L L O HW Y N O R T H B O U N D O F F R A M P S AN LU I S O B I S POCRE E K A G R I C U L T U R A L F A R M R D AGRICULTURAL FIELD ARUNDO DONAX HAND REMOVAL AREA ARUNDO DONAX MECHANICAL REMOVAL AREA COIR LOG EROSION CONTROL FABRIC 30 601500 SCALE 1 INCH = 30 FEETN INVASIVE SPECIES REMOVAL ANDEROSION CONTROL PLANGS CM LEGEND GS DSC NOTES CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 AT 34" X 22" DRAWING SIZE SCALE ACCORDINGLY IF REDUCED L-102 32 SSSSAN LUIS OBISPO CREEKAGRICULTURAL FIELDAGRICULTURAL FARM RDCABRILLO HWY NORTH BOUND OFF RAMPUPLANDDRIP ZONEWESTRIPARIANOH ZONENORTHRIPARIANOH ZONESOUTHRIPARIAN OHZONE EASTUPLAND DRIPZONEIRRIGATIONPIPEBRIDGEMYPOC QQWW POCQYMW30601500SCALE1 INCH = 30 FEETNIRRIGATION NOTESIRRIGATION LEGENDIRRIGATION PIPE CHART2L-5CITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONCALLE JOAQUIN STREAM RESTORATION MAY 2020911335590% PLANSET6L- 46L- 4GSCMGSDSC1"=10'-0"IRRIGATION PLAN33L-103 2"San Luis Obispo CreekRevegetation in ProgressTo enKanFe fisK anG ZiOGOife Kabitat forFonservation anG Pitigation purposesCOoseG to pubOiF entry No Oittering or GuPpingNo unautKori]eG veKiFOe use No FaPpingNo fires Dogs proKibiteG9ioOators Pay be subMeFt to penaOty)or Pore inforPation on tKe Restoration go to ZZZsOoFityorgCity of San Luis Obispo.\SLO city logo trans.tifIRRIGATIONRECYCLED WATERDO NOT DRINKNO BEBERIRRIGATIONRECYCLED WATERDO NOT DRINKNO BEBERTREE PLANTING DETAILNTS1TREE PLANTING ON SLOPENTS2POLE PLANTING DETAILNTS43ACORN PLANTING DETAILNTS5TYPICAL WOOD STAKE DETAILNTSMISCELLANEOUS DETAILSGSCMGSDSCRECYCLED WATER SIGNNTS6RESTORATION SIGNNTS7CITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONCALLE JOAQUIN STREAM RESTORATION MAY 2020911335590% PLANSETRECYCLED WATER SIGN LETTERING DETAILNTS8L-10434 11011567893412121360"18"24"MANIFOLD CONNECTIONSDRIPPERLINE END FLUSH VALVENTS1NTSNTSIRRIGATION DETAILSGSCMNTSNTSQUICK COUPLER VALVE BOX3SPRINKLER ON BRACED RISER ON RIPARIAN BANK4SUBSURFACE DRIPLINE5SUBSURFACE DRIPPLERLINE6NTSSTEEL PIPE ON PIPE BRIDGE7NTSTHRUST BLOCKS7GSDSCCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONCALLE JOAQUIN STREAM RESTORATION MAY 2020911335590% PLANSETL-10535 DOWNSTREAM ECF RUN WIDTHMAX. 18"36" MAX. DISTANCE INANY DIRECTION, TYPICALSTAKE @ 18" O.C.@ ALL EDGESOF ECF TYPICALDOWNSLOPEPLACE STAKES AT A SUFFICIENT DISTANCE FROMEDGE OF ECF TO PREVENT UNRAVELINGSTREAM FLOW (DOWN-VALLEY) DIRECTIONSTREAM FLOW (DOWN-VALLEY) DIRECTIONKEY EVERY 2ND ECF RUN INCHECK SLOTMIN. 12" OVERLAP24" WOOD STAKES @ 18" O.C. @ LAPSDOWN SLOPEEDGE OF DOWNSTREAM ECF RUN BELOWUPSTREAM ECF RUNUPSTREAM EDGE OF ECF.KEY TRENCHINSTALL EROSION CONTROL FABRIC (ECF)PARALLEL TO SLOPEECF KEYED INTO TRENCH ANDWRAPPED OVER TRENCH ATUPSTREAM MOST EDGE WHERE ECFDOES NOT TIE INTO OTHER EROSIONCONTROL STRUCTURESECF KEYED INTO TRENCH AT TOP OF SLOPE, WRAP ECFOVER TRENCH ONLY IF BOTTOM (DOWNSLOPE) END IS NOTWRAPPED OVER BOTTOM (DOWNSLOPE) TRENCHKEY ECF INTO TRENCH AND WRAP OVER TRENCH AT BOTTOM OFSLOPE WHERE ECF DOES NOT TIE INTO OTHER EROSION CONTROLSTRUCTURESUPSLOPE ECF RUNLENGTH DOWNSLOPE ECF RUNLENGTH UPSTREAM ECF RUN WIDTHEDGE OF UPSTREAM OVERLAPPING ECF18"12" MIN.OVERLAPEDGE OF UPSLOPE OVERLAPPINGECF RUNEDGE OF DOWNSLOPE ECF RUN BELOWUPSLOPE ECF RUNSTAKE @ 18" O.C.@ ALL EDGESOF ECF TYPICALSTAKE @ 18" O.C. @ ALL EDGES OF ECF TYPICAL STAKE @ 18" INCHECKSLOTS TYP.STAKE @ 18" O.C.@ ALL EDGESOF ECF TYPICAL12" MIN. OVERLAPSTAGGER STAKES BY 9" O.C. TYP.2 ROWS OF 24" WOODSTAKES STAGGERED @18" O.C.@CHECK SLOTEROSIONCONTROLFABRIC24" WOOD STAKES@ 3' O.C. STAGGEREDIN THE FIELDNATIVESUBSTRATE ORENGINEERED FILLFLOW DIRECTION12" OVERLAP9" MIN12" OVERLAPEX. GRADEEX GROUNDCOMPACTED FILL ANDROCKSSTAKES @18" O.C.12"X12" MIN. KEY TRENCH12" MIN.EROSION CONTROL FABRIC TYPICAL INSTALLATION PLANNTS1EROSION CONTROL FABRIC TYPICAL INSTALLATION SECTIONNTS2DETAILS2L-6GSCMGSDSC1L-7CITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONCALLE JOAQUIN STREAM RESTORATION MAY 2020911335590% PLANSETL-10636 SEE SHEET L2 FOR CO IR LOGPLACEMENTDOWNSLOPE12" WIDE X 12" DEEP KEYTRENCH. FOLD ECF TWICEAND STAKE AT 18" O.C. @BOTTOM OF TRENCH,BACKFILL AND COMPACTSOIL TO 80% RELATIVEDENSITY.ECF, INSTALL FABRIC RUNS PERPENDICULAR TO CONTOURFINISHED GRADE24" WOOD STAKES @ 36" O.C. MAX IN FIELD, STAGGERED; 18" O.C. @ LAPS (DO NOTCUT FABRIC)12" DIA COIR WATTLE IN 6" DEEP TRENCH @ 10' O.C. MAX. SECURE HORIZONTALLY LEVEL (EXACTLY ONCONTOUR) WITH 36" LONG WEDGE SHAPE (NON-PRESSURE TREATED) WOOD STAKE @ 36" O.C. (SEE STAKECONSTRUCTION )PILE TOPSOIL EXCAVATED FROM TRENCHES ABOVE TRENCHES, TYP. ENSURE4"- 6" HEIGHT BETWEEN SOIL SURFACE AND TOP EDGE OF WATTLE12" WIDE X 12" DEEP KEYTRENCH-TRIPPLE LAYEREDECF STAKED AT 18" O.C. INBOTTOM OF TRENCH;BACKFILL TRENCH W/SOILAND COMPACT.NATIVE SUBSTRATEOR ENGINEERED FILL.BROADCAST SEED BELOW ECFUPSLOPE TRENCH KEYINSTALL POLE CUTTINGS WHEREINDICATED ON PLANEROSION CONTROL FABRIC - TYPICAL SECTION PERPENDICULAR TO STREAM FLOW DIRECTIONNTS1DETAILSGSCMGSDSCCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONCALLE JOAQUIN STREAM RESTORATION MAY 2020911335590% PLANSETL-10737 105 106107 108109110110 109 104 ICV WV TEL B O X CTVUTL VLTWMWV SSMH #4634(16-H-17)RIM=105.03INV=93.15RWVRWVWVWVWV WV 1041 0 7 10 6 105 3 S-5011 S-102 2 S-102 1PUMP STATION STRUCTURE AND WALL LAYOUT PLAN 0 5 102.5 SCALE 1 INCH = 5 FEET N 19 S-503 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG PUMP STATION STRUCTURE AND WALL LAYOUT PLAN38 S-101 Know what's below. Call before you dig. 1 95 100 110 120 95 100 110 120 0+75 1+00 1+50 2+00 2+50 2+75 A S-103 B S-103 C S-103 ℄ 8 1WALL PROFILE @ FRONT FACE OF WALL 2STAIRS CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG WALL PROFILE AND DETAILS39 S-102 Know what's below. Call before you dig. TYPICAL CMU WALL 1 17 7 MCJ @ C CMU WALL A CMU WALL B CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG WALL SECTIONS40 S-103 Know what's below. Call before you dig. UTL VLT15S-5033 E-10720S-503 19 S-503 19 S-50 3 17 S-50 3 19 S-503 18 S-50 3 14 S-50 2 8 S-502 15 S-503 2 - 2 E-107 1SLAB PLAN004'2' 1/2" = 1'-0 N CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG CONCRETE SLAB PLAN41 S-104 Know what's below. Call before you dig. 2CORNER DETAIL CONCRETE COVER OVER CONCRETE FOOTING AT REINFORCING STEEL 1 SIDEWALK SLAB JOINTS 2 CONSTRUCTION JOINT PIPES AND CONDUITS 5 WEAKENED PLANE JOINT 2B 2A EXPANSION JOINT 2C THICKENED EDGE SLAB ON GRADE 3 EXPANSION JOINT 6CONSTRUCTION JOINT CJ3 4 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG STRUCTURAL DETAILS - 142 S-501 Know what's below. Call before you dig. CONTROL JOINT 7 HANDRAIL POST POCKET 13 REMOVEABLE HANDRAIL 14 TYPICAL STAIR 8 TYPICAL STAIR 9 HANDRAILS 10 HANDRAIL DETAILS 11 HANDRAIL DETAILS 12 REMOVABLE CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG STRUCTURAL DETAILS - 243 S-502 Know what's below. Call before you dig. 16COLLAR BEAM 15 @ LIFT STATION SLAB 17 TYP. FENCE POST & POCKET PERIMETER FENCE 19 EDGE OF EQUIPMENT PAD DETAIL20 REMOVABLE HANDRAIL POSTS 18 LIGHT POLE FOOTING 21 DAVIT FOOTING 22 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG STRUCTURAL DETAILS - 344 S-503 Know what's below. Call before you dig. CONSTRUCTION JOINT CJ2 TESTS AND INSPECTIONS CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 DC NR SEE DWG SPECIAL INSPECTION45 S-504 Know what's below. Call before you dig. CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56ELECTRICAL LEGEND AND ABBREVIATIONSE-101 46 DD AR CU/NG CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 SINGLE LINE DIAGRAM - INTERIM PHASE 1 GENERATOR RECEPTACLE (EXIST.) EXISTING FACILITY SINGLE LINE DIAGRAM - NEW FACILITY 2 PANEL "A" 160A, 240V, 3-PH MANUAL TRANSFER SWITCH (TEMPORARY) TRANSFER SWITCH (EXIST.) SERVICE METER BOX (EXIST.) 20HP (FLA = 54 AMPS) PUMP LP-01 200A GENERATOR RECEPTACLE (EXISTING, RELOCATED) 60 kW GENERATOR 200A UTILITY METER MCC, 200A, 240/120V, 3PH, 4-WIRE, 42K AICS 40A 2P 200A 3P 3 M200A 3P MCC & ICP ELEVATION 3 MCC C/B GEN C/B MAIN C/B ATSPANEL "A" PUMP LP-01 PUMP LP-02 COMMON CONTROLS ICP 36" 20"20"20" PG&E METER PG&E SERVICE CONDUIT PER PLANS GENERATOR RECEPTACLE CONCRETE PAD 200A, 240V, 3-POLE AUTOMATIC TRANSFER SWITCH G PG&E 240/120V, 3-PHASE, 4-WIRE SERVICE 200A 3P WP ENCLOSURE NOT SHOWN FOR CLARITY 200A 3P 2 2 3 100A MCP 3 100A MCP 3 3 4" CO TO PG&E POWER POLE NOTES: PROVIDE CONDUIT AND WIRE FOR TEMPORARY POWER TO NEW MOTOR CONTROL CENTER. REMOVE TEMPORARY CONDUIT AND WIRE AFTER THE NEW FACILITY IS OPERATIONAL AND THE POWER SERVICE HAS BEEN INSTALLED BY PG&E. REMOVE EXISTING ELECTRICAL EQUIPMENT AFTER PG&E HAS PROVIDED PERMANENT POWER. RELOCATE EXISTING GENERATOR RECEPTACLE TO NEW PERMANENT INSTALLATION AS SHOWN ON DETAILS 2 AND 3. EXTEND CONDUIT AND CABLES TO TOP OF POWER POLE. PROVIDE NEW WEATHERHEAD AND LEAVE 4' OF WIRE FOR CONNECTION TO PG&E OVERHEAD POWER LINES. REFER TO SHEET E-106, DETAIL 2. DO NOT USE NEW GENERATOR FOR CONSTRUCTION OR FOR TEMPORARY POWER. 1 2 3 2"C-4#2/0 + 1#6 GND.1 LOAD SCHEDULE 20PUMP LP-01 PUMP LP-02 PANEL A 20 21.5 21.5 LOAD DESCRIPTION HP KVA FLA 2 SUB-TOTAL: 25% OF LARGEST MOTOR: TOTAL: 45 5.4 50.4 121.4 SITE LIGHT SWITCH MANUFACTURER'S CABLE PULLBOX PB-1 20HP (FLA = 54 AMPS) PUMP LP-02 SINGLE LINE DIAGRAMS AND ELEVATIONE-102 47 EXISTING PG&E POWER POLE 4 472"90"5 5 2"C-4#3/0 + 1#6 GND. DD AR CU/NG ICV TEL B O X CTVUT L V L T UTL VLT4" DB L C H K V L V W W G1G1G1G1OHOHOHOHOHOHOHOHOHT T T T T T T T T T EOIL6OIL6OIL6OIL6OIL6OIL6OIL6WM12SS G2G2W W E E E E E E E E EW W W W T T T T T T T E E E E E E E E E OH 1 LIGHT POLE PUMP LP-02 PANEL A PUMP LP-01 ICP UTILITY METER EXISTING PG&E POLE #1009608620 GFI, WP 1 3 MCC CONTROL PANEL GENERATOR 53 LT-021A 34 PULLBOX PB-1 WET WELL FE-141 LSH-141 FLOWMETER VAULT CLASS 1, DIVISION 2 3 1 2 2"C-4#2/0 + 1#6 GND. EXISTING TRANSFER SWITCH EXISTING DISCONNECT EXISTING PG&E METER LT-021B LSHH-011 CLASS 1, DIVISION 1 VALVE VAULT CLASS 1, DIVISION 2 4 4 1 VAULT INTRUSION SWITCH ZS-995 VAULT INTRUSION SWITCH ZS-997 2 5 5 5 2 6 EXISTING PG&E POLE TO REMAIN, REFER TO SHEET E-106, DETAIL 2 CLASS 1, DIVISION 2 SIGNAL BOX FOR FUTURE CITY PROJECT (2) 2" C.O. FOR FUTURE CITY PROJECT 5 ANTENNA 7 TEMPORARY MANUAL TRANSFER SWITCH CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 1ELECTRICAL SITE PLAN NOTES: CLASS I, DIV. 1 HAZARDOUS AREA WITHIN WET WELL. CLASS I, DIV. 2 HAZARDOUS AREA WITHIN VAULTS. 2'W x 3'L x 3'D IN GRADE PULLBOX. H2O TRAFFIC RATED. LABEL COVER "ELECTRICAL". PROVIDE EXPLOSION PROOF (CLASS 1, DIV. 2) CONDUIT SEALS INSIDE THE PULLBOX. PROVIDE EXPLOSION PROOF SEAL FOR ALL CONDUITS ENTERING AND LEAVING HAZARDOUS AREA. REMOVE AND DISPOSE OF EXISTING ELECTRICAL PANEL AND ASSOCIATED CONDUIT AND WIRE AFTER INTERIM PHASE. EXTEND CONDUIT AND CABLES TO TOP OF POLE. REFER TO SHEET E-102, DETAIL 1 AND SHEET E-106, DETAIL 2. MAINTAIN 12" MINIMUM SEPARATION FROM OTHER CONDUITS, WATER LINES AND GAS LINES. 1 2 3 N 00 1/4" = 1'-0 4'8' 4 5 CALLE JOAQUIN LIFT STATIONELECTRICAL SITE PLANE-103 48 6 7 DD AR CU/NG 4 GROUND WELL DETAIL #4 BC IN BOTTOM OF CONCRETE PAD GENERATOR MCC #4 BC 3/4"C-1#4 BC CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 1GROUNDING PLAN P02A 120/240V, 1PH, 3WBUS: AMPS NAMEPLATE A 1 LTG WATTAGE A B VOLTS: OUTLETS REC MISC MISC 2 10,000 AICS 20A-1P U.O.N. MTG. OUTLETS LTG REC MAIN KW + LCL TOTAL LOAD KW= TOTAL LOAD VOLTSKW AT 1PH=AMPS LIGHTING 240 MCC WATTAGE BA 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 COMMON CONTROLS GEN. HEATER GEN. BATTERY CHARGERMCC HEATERS RECEPTACLES SPACE 100 40A/2P 300 180 400 3 1 4 700 180 1 1 50 1000 200 250 1000 2.1 2.1 9 SPARE SPACE SPARE N 00 4'2' 1/2" = 1'-0 CONDUIT SCHEDULE CONDUIT POWER CONTROL FROM TO REMARKSGROUNDGROUND SIZE SIZE QTY.SIZE QTY.SIZE QTY.SIZE QTY.SIZE 2"MANUFACTURER CABLE PUMP LP-01 PB-1 INTRINSICALLY SAFE CABLE 2"3 #4 1 #8 PB-1 (PUMP LP-01)MCC 2"MANUFACTURER CABLE PUMP LP-02 PB-1 INTRINSICALLY SAFE CABLE 2"3 #4 1 #8 PB-1 (PUMP LP-02)MCC 2"4 #3/0 1 #2 GENERATOR MCC 1"3 #12 1 #12 GENERATOR MCC (PANEL A)GEN. HEATER & GEN. BATTERY CHARGER 2"4 #3/0 1 #2 UTILITY METER PG&E POWER POLE COORDINATE POWER POINT OF CONNECTION WITH PG&E 1"MANUFACTURER CABLE LT-021A ICP 1"MANUFACTURER CABLE LT-021B ICP 1"MANUFACTURER CABLE LSHH-011 MCC 1"4 #14 1 #14 MCC (COMMON CONTROLS)ICP LSHH-011, BACKUP SYSTEM ACTIVE 1"MANUFACTURER CABLE FE-141 FIT-141 1"2 #14 1 #14 GENERATOR MCC ATS 1"10 #14 1 #14 GENERATOR ICP GENERATOR AND BATTERY CHARGER SIGNALS 1"2 #14 1 #14 LSH-141 ICP 1"2 #14 1 #14 ATS GENERATOR 1"6 #14 1 #14 ATS ICP 1"2 #14 1 #14 VALVE VAULT INTRUSION SWITCH ZS-995 ICP 1"2 #14 1 #14 VAULT INTRUSION SWITCH ZS-997 ICP 1"20 #14 1 #14 MCC ICP 1"MANUFACTURER CABLE PUMP LP-01 PB-1 MOISTURE AND TEMP 1"4 #14 1 #14 PB-1 MCC MOISTURE AND TEMP 1"MANUFACTURER CABLE PUMP LP-02 PB-1 MOISTURE AND TEMP 1"4 #14 1 #14 PB-1 MCC MOISTURE AND TEMP 2"1 ANTENNA CABLE ICP-1 NEW ANTENNA P03 P05 P04 C01 C02 C04 C05 C06 C07 C03 C03A C10 C09 C08 P01A P01 P02 C11 C12 C13 C14 C15 C16 GROUNDING PLAN,PANEL AND CONDUIT SCHEDULESE-104 49 C17 DD AR CU/NG CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 CONTROL SCHEMATIC 1 * MOTOR HIGH TEMP FAILR CR2 30 31 35 18 16 17 13 15 14 M 11 10 9 7 8 6 4 3 TD0 2 1 RUNG ETM CR1 1-180 SEC. AUTO AUTO * AUTO HAND TD0 M W 19 CR2 NOTES: CONDUCTIVITY SENSOR RELAY. (SUPPLIED BY PUMP MANUFACTURER TO BE INSTALLED IN STARTER CUBICLE). INSTRINSICALLY SAFE RELAY. WARRICK SERIES 17XXG0 CLOSES INSTANTANEOUSLY UPON ENERGIZATION OF RELAY. STARTS TIMING & OPENS UPON TIMING OUT. PROVIDE A WARNING SIGN: "WARNING: DO NOT OPERATE WITH WET WELL EMPTY". SET THESE TIMERS JUST LONG ENOUGH TO PREVENT RACING. THESE CABLES SHALL BE PROVIDED TOGETHER WITH PUMP POWER CABLES BY PUMP MANUFACTURER. OPENS PRIOR TO TRANSFER AND CLOSES AFTER TRANSFER. AR2 M AR1 A AR2 SYMBOLS (THIS DWG. ONLY) ICP DOOR MOUNTED OL 5 12 FAULT RESET TO MOTOR MOISTURE PROBE LE-1x1 32 READY TO CR1 * RUN TO M * MOISTURE ALARM TO AR1 * AR2 TEMP TO * ~ LSHH-011 CR10 TD10 A TD10 PUMPS ON BACKUP A-2 70 HIGH-HIGH LEVEL SWITCH ACTIVATED TO CR10 71 BACKUP SYSTEM ACTIVE TO CR11 73 LP-1 CALL CR11 74 CR12 50 51 52 OFF XOO OOX OOX OXO OOX MOISTURE ALARM CALL AR1 LP-2 CALL A TD11 LP-1 CALL TIMING IN PROGRESS A TD12 LP-2 CALL IN PROGRESS G TD11 LP-1 CALLED G TD12 LP-2 CALLED AR1 AR2 M (LP-01) M (LP-02) FIT-141 TEST BACKUP 53 54 55 56 57 59 CR12 72 ICTOOX XO M1 TD12A TD12A CR11 M1 61 58 60 0-30 SEC. 0-30 MIN. 0-30 SEC. 0-30 MIN. 33 COMMON CONTROLS MX 34 COMMON CONTROLS MX MX ~ COMMON CONTROLS 2 * * 4 CONTROL POWER ON 4,14,32 4,19,35 30 10,31,37,38 18 33,34 51,70 52 54,59 56,61 57,71,73 60 72,74 CR10 TD11 TD12 CR11 CR12 CR11 (PUMP #1) CR12 (PUMP #2) ALARM AND SHUTDOWN MOISTURE FAIL ALARM ONLY 240V, 3Ø N (PWR) TO MOTOR KLIXON TEMPERATURE PROBE ATS CONTROL SCHEMATIC DIAGRAMSE-105 50 36 OL OVERLOADS TO * 37 38 RESET DD AR CU/NG 6' HIGH CHAIN LINK FENCE6' HIGH CHAIN LINK FENCE MCC LSHH-011 MANUFACTURER'S CABLES CLASS 1, DIV. 1 AREA1 C01 C02 C03 P01A P02A C01 C02 C03 P01 P02 PULLBOX PB-1 LT-021B LT021A C15 C13 C16 C14 CLASS 1, DIV. 2 AREA 18" 3'-0"3'-0" CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 1FRP LIFT STATION NOTES: PROVIDE CLASS 1, DIV. 1 SEALS FOR ALL CONDUIT ENTERING OR LEAVING RATED AREAS. 1/2" X 4", 316SST OPEN EYE BOLT, DRILL AND EPOXY IN CONCRETE WALL, 3" EMBEDMENT. 2 1 ELECTRICAL DETAILSE-106 51 2EXISTING PG&E POWER POLE EXISTING ANTENNA TO REMAIN OPERATIONAL UNTIL NEW ICP HAS BEEN INSTALLED AND TESTED AND THE PUMP STATION IS READY FOR OPERATION EXISTING PG&E POLE TO REMAIN. PROVIDE NEW CONDUIT, NEW WIRES AND NEW WEATHERHEAD. REFER TO SHEET E-102, DETAIL 1 AND SHEET E-103. PROVIDE A TEMPORARY GENERATOR FOR THE TRANSITION FROM THE EXISTING POWER SERVICE TO THE NEW POWER SERVICE TO MAKE SURE THAT THE NEW PUMP STATION IS ABLE TO OPERATE. DD AR CU/NG CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 NOTE: FIXTURE TYPE SHALL BE EXTERIOR POLE MOUNTED LED FIXTURE. CREE XSP LED MOST CURRENT VERSION, TYPE 3 OPTICS, 9612 INITIAL LUMENS, 4000K HIGH EFFICACY MODULE, 120-277V, SILVER COLOR. PROVIDE WITH FUSE, UTILITY LABEL AND EXTERIOR WATTAGE LABEL. COMPLY WITH CITY ENGINEERING STANDARD 1010, SECTION G. POLE SHALL BE 4" ROUND ALUMINUM 20' ABOVE BASE AND RECEPTACLE 18" FROM BASE. CLEAR ALUMINUM FINISH. POLE MOUNTED FIXTURE 1 NOTES: CONCRETE SHALL BE CLASS `A'. REINFORCING STEEL SHALL BE GRADE 60 ASTM A615. ALL APPLICABLE REINFORCEMENT SHALL BE IN PLACE AT THE TIME OF INSPECTION. GROUND CONDUCTOR IN SLAB. 6" TYP.4"8"GROUND WELL DETAIL 4 GENERATOR PAD DETAIL 3CONTROL PANEL PAD DETAIL 2 GENERATOR WIRING DIAGRAM 5 FLUSH-MOUNTED RECEPTACLE IN POLE HEX NUT, LEVELING NUT AND WASHERS POLE BASE PLATE 1" x 3' ANCHOR BOLTS TOP OF CONCRETE PAD ELECTRICAL CONDUIT(S) PER PLANS (6) #4 REBAR VERTICAL REINFORCEMENT #3 REBAR @ 9" O.C. HORIZONTAL REINFORCEMENT HANDHOLE BOLT COVER 3" NON-SHRINK GROUT POLE 3'-0"5'-0"24" Ø 1/2" CHAMFER ALL AROUND GRADE #4 @ 12" ON CENTER GRADE #5 @ 12" E.W. T&B 1/2" CHAMFER ALL AROUND 6"18"11" x 17" x 12" DEEP PRECAST CONCRETE HANDHOLE WITH CONCRETE COVER LABELED: 'GROUND' CONDUIT AND WIRE PER PLANS FINISH GRADE GROUND CONNECTOR 6" GRAVEL BASE 10' GROUND ROD PER SPECIFICATION SECTION 260526 NORMAL POWER FROM MCC 3-POLE AUTOMATIC TRANSFER SWITCH STANDBY GENERATOR STANDBY GENERATOR HOUSING GROUND BONDED TO ENCLOSURE G N G Ø Ø Ø TO MCC 4 N GROUND GRID CLASS A CONCRETE PER SPECIFICATION SECTION 030500 ELECTRICAL DETAILSE-107 52 DD AR CU/NG NOTES: CONCRETE SHALL BE CLASS `A'. REINFORCING STEEL SHALL BE GRADE 60 ASTM A615. ALL APPLICABLE REINFORCEMENT SHALL BE IN PLACE AT THE TIME OF INSPECTION. GROUND CONDUCTOR IN SLAB. 6EXP. JT. ALL AROUND EXP. JT. ALL AROUND 6 - CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE Know what's below. Call before you dig.INSTRUMENTATION LEGEND AND SYMBOLS53 N-001 MJ MG SEE DWG GY CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56- 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE Know what's below. Call before you dig.COMMUNICATION BLOCK DIAGRAM54 N-002 KR SA SEE DWG AR CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE Know what's below. Call before you dig.CALLE JOAQUIN LIFT STATION P&ID55 N-003 KR SA SEE DWG AR A CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: DRAWING NO.CALLE JOAQUIN LIFT STATION REPLACEMENTOCTOBER 2020 91133 56 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE Know what's below. Call before you dig.INSTRUMENTATION DETAILS56 N-004 KR SA SEE DWG AR