HomeMy WebLinkAboutRECORDS REQUEST - 955 MONTEREY - FIRE INSPECTION - 7-24-2018INSPECTION WORKSHEET (FIRE-04371-2016) San Luis Obispo Cellphone: XXX-XXX-XXXX. Address: 990 Palm Case Number: Inspection Date: Inspector: Case Module: Inspection Status: Inspection Type: PLOCC-114621-2014 07/24/2018 Julianna Hutchinson Plan In Violation Fire Business Inspection Job Address:Parcel Number:955 Monterey St San Luis Obispo, CA 93401 002-431-007 Contact Type Company Name Name Tenant [Anderson Hotel] Checklist Item Passed Comments F.S. Provide 5-Year Certification - Scope. This document establishes the minimum requirements for periodic inspection, testing, and maintenance of water based fire protection systems, including land-based and marine applications. YES Provide 5 year fire sprinkler report when due at end of this calendar year. F.S. Reduce Storage 18" Below Heads - Ceiling clearance. Storage shall be maintained a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of the building. NO Maintain clearance of 18" below fire sprinklers - location was closet behind barbershop as well as basement file room. F.A. Annual Test Record Required - Testing frequency. Unless otherwise permitted by other sections of this Code, testing shall be performed in accordance with with the schedules in Table 14.4.5 or more often if required by the authority having jurisdiction. NO Provide a copy of the annual fire alarm report. E. Provide/Repair Illum Exit Signs w Back-Up Power - Internally illuminated exit signs. Electrically powered, self luminous and photoluminescent exit signs shall be listed and labelled in accordance with UL 924 and shall be installed in accordance with the manufacturer's instructions and Chapter 27 of the California Building Code. Exit signs shall be illuminated at all times. NO Thai Palace water heater area - emergency lights need to be repaired/replaced. E. Remove Storage/Obstructions to Aisles/Exit - General. The required width of aisles shall be unobstructed. NO Remove wheelchair from emergency exit pathway and maintain area outside of Apartment 209 free of obstructions, no exceptions. Immediate hazard to be corrected today. EL. Remove/Provide Approved Ext. Cord/Multiplug - Power supply. Extension cords shall be plugged directly into an approved receptacle, power tap, or multi plug adaptor and, except for approved multiplug extension cords, shall serve only one portable appliance. NO Plug microwave oven directly into an outlet - location is in Veterans Office. S.H. Repair/Maintain Fire Rated Wall/Ceiling/Door - Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire resistive coatings and sprayed fire-resistant materials applied to structural members and fire resistant joint systems) shall be maintained. NO Ceiling cover in storage closet next to barber shop. Basement also has several areas needing fire resistant caulk. Check remainder of structure for compliance. Jul 24, 2018 Page (1) INSPECTION WORKSHEET (FIRE-04371-2016) Checklist Item Passed Comments S.H. Seismic Strapping/Maint./Repair Waterheaters - Protection from seismic damage. Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one third and lower one third of its vertical dimensions. At the lower point, a minimum distance of 4 inches shall be maintained above the controls with the strapping. NO Water heaters on each floor need seismic strapping. A. General Inspection Comments - General Inspection Comments YES Continue to maintain smoke/CO detectors in each unit. A reinspection will be conducted in approximately 21 days. For any questions please contact this inspector at (805) 431-2217 or by email at jhutchinson@slocity.org. Jul 24, 2018 Page (2) Maint manager/Bryan Lloyd Hutchinson, Julianna (Inspector)