Loading...
HomeMy WebLinkAboutPRR21224_Walter_Responsive.pdfFrom:Oetzell, Walter To:Leveille, Brian Subject:Final Inspection: Leitcher Building Date:Tuesday, June 12, 2018 10:46:00 AM Attachments:image001.png Hi Brian, I got a call from Matt Hoffman of NK Builders ( who says he’s ready for Planning’s final inspection for the Leitcher House on permit BLDG-1332-2015 (667 Monterey). You reviewed plans (see PLBLDG-1088-2018) and so I told him I would relay his information to you so you can arrange an inspection. Let me know if I can be of any help setting this up… Walter Oetzell Assistant Planner Community Development Development Review 919 Palm Street, San Luis Obispo, CA 93401-3218 E woetzell@slocity.org T 805.781.7593 slocity.org From:Cornejo, Rafael To:Thom Jess Subject:RE: Leitcher Building Date:Thursday, September 24, 2015 1:53:19 PM Hello Thom, I have time this afternoon at 3:00 PM. Please let me know if this time works for you. Thanks Rafael From: Thom Jess [mailto:tjess@arris-studio.com] Sent: Thursday, September 24, 2015 1:48 PM To: Cornejo, Rafael Cc: Michael Hodge; Shawn Subject: Leitcher Building   Hi Rafael,   We are working through some items on the Leitcher House (Part of the Monterey Place project) that involve the occupancy classification of the building and openings relative to the property line.  I thought it would be helpful to walk through these items with you just to make sure we are on the same page and we don’t head down the wrong direction.   Do you have any time available either this afternoon or tomorrow afternoon?  I don’t think it will take more then 15-20 minutes max.   Thank you,   Thom Jess | Arris Studio Architects 1306 Johnson Avenue San Luis Obispo, CA 93401 (805) 547-2240 Office (805) 547-2241 Fax Email: tjess@arris-studio.com Web: ARRIS-STUDIO.com   From:Cornejo, Rafael To:Maggio, Rodger; Oetzell, Walter; Schneider, Anne Cc:Davidson, Doug Subject:RE: Meeting on Monterey Place LLA map ? Date:Wednesday, July 29, 2015 5:07:04 PM Rodger, we need to be careful as the R-3 occupancy classification under the CBC does specify the following uses as permitted uses: · Boarding Houses (nontransient) with 16 or fewer occupants · Boarding Houses (transient) with 10 or fewer occupants · Same for congregate residences. Rafael From: Maggio, Rodger Sent: Wednesday, July 29, 2015 4:50 PM To: Oetzell, Walter; Schneider, Anne; Cornejo, Rafael Cc: Davidson, Doug Subject: RE: Meeting on Monterey Place LLA map ? As a reference, please look at the CRC 1.1.3 (Scope): Specifically states Owner-occupied lodging houses with 5 or fewer guestrooms shall be permitted to be constructed as One and Two family dwellings using the CRC. Please note the italics and double lines in the margin indicating that this is both a change in code and State Fire Marshal specific language. The building classification “Boarding House (transient)” is not included in the CRC. If the use of the building is other than owner-occupied it would be covered under the CBC as either R-1 (transient) or R-2 (non-transient). From: Oetzell, Walter Sent: Wednesday, July 29, 2015 12:52 PM To: Schneider, Anne; Maggio, Rodger; Cornejo, Rafael Cc: Davidson, Doug Subject: Meeting on Monterey Place LLA map ? Hello All, Would you be willing to meet with the applicant to discuss the lot line adjustment proposed for 667 Monterey (LLA 56-14), to help us move toward some final action on this application? From our recent discussions about adjusting lot lines to place a line around the Leitcher Building, it is apparent that the applicant’s argument (see below) is not supported by Building or Fire. The applicant contends that exterior fire wall ratings and limitation on building openings (particularly those of the reconstructed porch around the building) will not apply to the relocated building because it should be classified as an R-3 Occupancy Type under the 2013 CBC, as a Boarding House (transient). It will be useful to discuss with the applicant, in person, the reasons that the proposed 2- guest-room Bed & Breakfast Inn could not be considered a Boarding House (transient), and thus would not be classified as an R-3 Occupancy Type, and why it would instead be classified as an R-1 Occupancy Type. It may also be helpful to discuss how the current proposal relates to the future phases of the larger Monterey Place project, and the possibility of achieving compliance with building safety codes through “no-build” easements to provide proper building separation. Let me know if you are available for such a meeting, and if so, I will set something up with the applicant. Thanks for your help. --   Walter Oetzell, Assistant Planner (805)781-7593 | woetzell@slocity.org From: Mike Hodge [mailto:hodgecompany@gmail.com] Sent: Tuesday, July 07, 2015 1:18 PM To: Oetzell, Walter Subject: Monterey Place LLA map Walter…below are answers from the Architect to the questions in your last e-mail pertaining to the lot line adjustment for the future location of the Leitcher House, which seems to provide resolution. The remaining issue is the lot line location on the west side. The attached exhibit shows a 5’ setback on the west side, as required by building, and the setbacks to the future buildings on the west and east sides. I hope we can now get scheduled for a hearing. Thanks. 1. Plans to show the required exterior wall fire rating for any new proposed property line in accordance with Chapter 6 Table 602 2013 CBC.  Please note that “no openings are permitted within 5 to 10 of proposed property line.  ( No occupancy classification was specified on plans submitted) · The building is classified as a Boarding House (R-3) occupancy. Per Table 602, item i, fire-resistance rating shall not be required where the fire separation distance is 3 feet or more and equipped with automatic sprinkler system. 2. Verify allowable openings and openings protective in accordance with Table 705.8 2013 CBC.  It is assumed that the (F) notation is for “future location of building exterior walls. · Per 705.8.1, Exception 2, buildings whose exterior walls are not required to be fire-resistance rated shall be permitted to have unlimited unprotected openings. 3. Verify that any existing projections are in compliance with requirements in Table 705.8 2013 CBC. · N/A. The existing porch will be reconstructed and the new porch will be meet the exception listed above. Hodge Company Land Planning + Civil Engineering Michael Hodge, P.E. Mailing: 351 San Miguel Avenue San Luis Obispo, Ca. 93405 Office: 867 Pacific Street, Suite 120 San Luis Obispo, Ca. 93401 P: 805.215.8753 F: 805.540-5241 E: hodgecompany@gmail.com From:Cornejo, Rafael To:Oetzell, Walter; Schneider, Anne; Maggio, Rodger Cc:Davidson, Doug Subject:RE: Meeting on Monterey Place LLA map ? Date:Wednesday, July 29, 2015 2:01:13 PM Yes, I think a meeting will be very productive. Perhaps a pre-meeting will be adequate to discuss amongst ourselves the criteria used for the requirements that are being thought of. Rafael From: Oetzell, Walter Sent: Wednesday, July 29, 2015 12:52 PM To: Schneider, Anne; Maggio, Rodger; Cornejo, Rafael Cc: Davidson, Doug Subject: Meeting on Monterey Place LLA map ? Hello All, Would you be willing to meet with the applicant to discuss the lot line adjustment proposed for 667 Monterey (LLA 56-14), to help us move toward some final action on this application? From our recent discussions about adjusting lot lines to place a line around the Leitcher Building, it is apparent that the applicant’s argument (see below) is not supported by Building or Fire. The applicant contends that exterior fire wall ratings and limitation on building openings (particularly those of the reconstructed porch around the building) will not apply to the relocated building because it should be classified as an R-3 Occupancy Type under the 2013 CBC, as a Boarding House (transient). It will be useful to discuss with the applicant, in person, the reasons that the proposed 2- guest-room Bed & Breakfast Inn could not be considered a Boarding House (transient), and thus would not be classified as an R-3 Occupancy Type, and why it would instead be classified as an R-1 Occupancy Type. It may also be helpful to discuss how the current proposal relates to the future phases of the larger Monterey Place project, and the possibility of achieving compliance with building safety codes through “no-build” easements to provide proper building separation. Let me know if you are available for such a meeting, and if so, I will set something up with the applicant. Thanks for your help. --   Walter Oetzell, Assistant Planner (805)781-7593 | woetzell@slocity.org From: Mike Hodge [mailto:hodgecompany@gmail.com] Sent: Tuesday, July 07, 2015 1:18 PM To: Oetzell, Walter Subject: Monterey Place LLA map Walter…below are answers from the Architect to the questions in your last e-mail pertaining to the lot line adjustment for the future location of the Leitcher House, which seems to provide resolution. The remaining issue is the lot line location on the west side. The attached exhibit shows a 5’ setback on the west side, as required by building, and the setbacks to the future buildings on the west and east sides. I hope we can now get scheduled for a hearing. Thanks. 1. Plans to show the required exterior wall fire rating for any new proposed property line in accordance with Chapter 6 Table 602 2013 CBC.  Please note that “no openings are permitted within 5 to 10 of proposed property line.  ( No occupancy classification was specified on plans submitted) · The building is classified as a Boarding House (R-3) occupancy. Per Table 602, item i, fire-resistance rating shall not be required where the fire separation distance is 3 feet or more and equipped with automatic sprinkler system. 2. Verify allowable openings and openings protective in accordance with Table 705.8 2013 CBC.  It is assumed that the (F) notation is for “future location of building exterior walls. · Per 705.8.1, Exception 2, buildings whose exterior walls are not required to be fire-resistance rated shall be permitted to have unlimited unprotected openings. 3. Verify that any existing projections are in compliance with requirements in Table 705.8 2013 CBC. · N/A. The existing porch will be reconstructed and the new porch will be meet the exception listed above. Hodge Company Land Planning + Civil Engineering Michael Hodge, P.E. Mailing: 351 San Miguel Avenue San Luis Obispo, Ca. 93405 Office: 867 Pacific Street, Suite 120 San Luis Obispo, Ca. 93401 P: 805.215.8753 F: 805.540-5241 E: hodgecompany@gmail.com From:Maggio, Rodger To:Cornejo, Rafael; Oetzell, Walter; Schneider, Anne Cc:Davidson, Doug Subject:RE: Meeting on Monterey Place LLA map ? Date:Wednesday, July 29, 2015 5:13:49 PM Correct, however the “order of precedence and use” clearly states how conflicts in code language are to be resolved. Being that the most specific and most restrictive shall prevail. I checked the code language with other States and they have identical language when it applies to transient lodging. This may need an official code interpretation from the SFM. From: Cornejo, Rafael Sent: Wednesday, July 29, 2015 5:07 PM To: Maggio, Rodger; Oetzell, Walter; Schneider, Anne Cc: Davidson, Doug Subject: RE: Meeting on Monterey Place LLA map ? Rodger, we need to be careful as the R-3 occupancy classification under the CBC does specify the following uses as permitted uses: · Boarding Houses (nontransient) with 16 or fewer occupants · Boarding Houses (transient) with 10 or fewer occupants · Same for congregate residences. Rafael From: Maggio, Rodger Sent: Wednesday, July 29, 2015 4:50 PM To: Oetzell, Walter; Schneider, Anne; Cornejo, Rafael Cc: Davidson, Doug Subject: RE: Meeting on Monterey Place LLA map ? As a reference, please look at the CRC 1.1.3 (Scope): Specifically states Owner-occupied lodging houses with 5 or fewer guestrooms shall be permitted to be constructed as One and Two family dwellings using the CRC. Please note the italics and double lines in the margin indicating that this is both a change in code and State Fire Marshal specific language. The building classification “Boarding House (transient)” is not included in the CRC. If the use of the building is other than owner-occupied it would be covered under the CBC as either R-1 (transient) or R-2 (non-transient). From: Oetzell, Walter Sent: Wednesday, July 29, 2015 12:52 PM To: Schneider, Anne; Maggio, Rodger; Cornejo, Rafael Cc: Davidson, Doug Subject: Meeting on Monterey Place LLA map ? Hello All, Would you be willing to meet with the applicant to discuss the lot line adjustment proposed for 667 Monterey (LLA 56-14), to help us move toward some final action on this application? From our recent discussions about adjusting lot lines to place a line around the Leitcher Building, it is apparent that the applicant’s argument (see below) is not supported by Building or Fire. The applicant contends that exterior fire wall ratings and limitation on building openings (particularly those of the reconstructed porch around the building) will not apply to the relocated building because it should be classified as an R-3 Occupancy Type under the 2013 CBC, as a Boarding House (transient). It will be useful to discuss with the applicant, in person, the reasons that the proposed 2- guest-room Bed & Breakfast Inn could not be considered a Boarding House (transient), and thus would not be classified as an R-3 Occupancy Type, and why it would instead be classified as an R-1 Occupancy Type. It may also be helpful to discuss how the current proposal relates to the future phases of the larger Monterey Place project, and the possibility of achieving compliance with building safety codes through “no-build” easements to provide proper building separation. Let me know if you are available for such a meeting, and if so, I will set something up with the applicant. Thanks for your help. --   Walter Oetzell, Assistant Planner (805)781-7593 | woetzell@slocity.org From: Mike Hodge [mailto:hodgecompany@gmail.com] Sent: Tuesday, July 07, 2015 1:18 PM To: Oetzell, Walter Subject: Monterey Place LLA map Walter…below are answers from the Architect to the questions in your last e-mail pertaining to the lot line adjustment for the future location of the Leitcher House, which seems to provide resolution. The remaining issue is the lot line location on the west side. The attached exhibit shows a 5’ setback on the west side, as required by building, and the setbacks to the future buildings on the west and east sides. I hope we can now get scheduled for a hearing. Thanks. 1. Plans to show the required exterior wall fire rating for any new proposed property line in accordance with Chapter 6 Table 602 2013 CBC.  Please note that “no openings are permitted within 5 to 10 of proposed property line.  ( No occupancy classification was specified on plans submitted) · The building is classified as a Boarding House (R-3) occupancy. Per Table 602, item i, fire-resistance rating shall not be required where the fire separation distance is 3 feet or more and equipped with automatic sprinkler system. 2. Verify allowable openings and openings protective in accordance with Table 705.8 2013 CBC.  It is assumed that the (F) notation is for “future location of building exterior walls. · Per 705.8.1, Exception 2, buildings whose exterior walls are not required to be fire-resistance rated shall be permitted to have unlimited unprotected openings. 3. Verify that any existing projections are in compliance with requirements in Table 705.8 2013 CBC. · N/A. The existing porch will be reconstructed and the new porch will be meet the exception listed above. Hodge Company Land Planning + Civil Engineering Michael Hodge, P.E. Mailing: 351 San Miguel Avenue San Luis Obispo, Ca. 93405 Office: 867 Pacific Street, Suite 120 San Luis Obispo, Ca. 93401 P: 805.215.8753 F: 805.540-5241 E: hodgecompany@gmail.com