Loading...
HomeMy WebLinkAboutPC-1011-20 (APPL-0233-2020 -- 1141 Ella St.)RESOLUTION NO. PC-1011-20 A RESOLUTION OF THE SAN LUIS OBISPO PLANNING COMMISSION OF SAN LUIS OBISPO, CALIFORNIA, DENYING AN APPEAL (FILED BY STEVEN GOSCHKE) THEREBY APPROVING A NEW THREE- STORY, 3,439-SQUARE FOOT SINGLE-FAMILY RESIDENCE, 967- SQUARE FOOT ACCESSORY DWELLING UNIT, AND A 1,031-SQUARE FOOT, FOUR-CAR GARAGE ON A SLOPED LOT, WHICH INCLUDES REQUESTED EXCEPTIONS FROM THE HILLSIDE DEVELOPMENT STANDARDS OF THE ZONING REGULATIONS TO ALLOW PORTIONS OF DOWNHILL BUILDING WALLS TO EXCEED 15 FEET IN HEIGHT AND TO ALLOW RETAINING WALLS UP TO 12 FEET IN HEIGHT, WITH A CATEGORICAL EXEMPTION FROM ENVIRONMENTAL REVIEW, AS REPRESENTED IN THE STAFF REPORT AND ATTACHMENTS DATED JUNE 24, 2020 (1141 ELLA STREET, APPL- 0233-2020) WHEREAS, the Architectural Review Commission of the City of San Luis Obispo meeting was conducted via teleconference, on April 20, 2020, recommending approval of this project to the Community Development Director of the City of San Luis Obispo based on consistency with the City’s Community Design Guidelines applicable to residential infill projects on hillside lots, pursuant to a proceeding instituted under ARCH-0816-2019, Didier & Beatrice Cop, applicant; and WHEREAS, the Community Development Director of the City of San Luis Obispo, on May 22, 2020, approved the above referenced residential infill project on a hillside lot; and WHEREAS, on June 1, 2020, Steven Goschke, as a member of the public, filed an appeal of the Community Development Director’s May 22, 2020 decision approving the project; and WHEREAS, the Planning Commission of the City of San Luis Obispo meeting was conducted via teleconference, on June 24, 2020, pursuant to a proceeding instituted under APPL- 0233-2020, Steven Goschke, appellant; and WHEREAS, the Planning Commission of the City of San Luis Obispo has duly considered all evidence, including the testimony of the applicant, interested parties, and evaluation and recommendations by staff, presented at said hearing; and WHEREAS, notices of said public hearings were made at the time and in the manner required by law; and NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of San Luis Obispo as follows: SECTION 1. Findings. The Planning Commission does hereby deny an appeal (APPL- Resolution No. PC-1011-20 1141 Ella Street, APPL-0233-2020 Page 2 0233-2020) of the Community Development Director’s decision, thereby granting final approval to the project (ARCH-0816-2019), based on the following findings: 1. The project will not be detrimental to the health, safety, and welfare of persons living or working at the site or in the vicinity because the project will be compatible with the site constraints and the character of the neighborhood, including buildings fronting Ella Street and the other flag lot west of the site, which have retaining walls taller than six feet and downhill building walls taller than 15 feet. 2. The project is consistent with General Plan Land Use Element policies related to hillside development (Chapter 1, Section 6.4), because the proposed project is located entirely within the urban reserve line, keeps a low profile and confirms to the natural slope by setting the structures into the slope, and minimizes grading by locating the structures as close to the street as possible while complying with setback standards. 3. The Architectural Review Commission reviewed the project on April 20, 2020 and found the project consistent with the City’s Community Design Guidelines applicable to residential infill projects because the project is compatible in scale, siting, and overall character with adjacent buildings. 4. The Architectural Review Commission reviewed the project on April 20, 2020 and found the project consistent with the City’s Community Design Guidelines applicable to hillside development because the apparent size of exterior wall surfaces visible from off the site are minimized through the use of single-story and small-scale elements, setbacks, overhangs, and other means of horizontal and vertical articulation to create shade and shadow, and break up building forms. 5. The project is consistent with the Hillside Development Standards of the Zoning Regulations (Section 17.70.090), except those identified for exception, because the grade of the driveway is 2% within 10 feet of the garage entries and does not exceed 20% for any one section, at no point is the foundation at a lower grade than the lowest floor line, no decks are proposed with visible underpinnings, there are no visible support structures proposed, and the structure uses horizontal and vertical articulation to prevent the creation of large flat building planes.   6. The applicant has provided clear and substantiated evidence that there is no practical way to comply with the provisions of Section 17.70.090 and that no other feasible alternatives will result in better implementation of other Zoning Regulations or General Plan policies while allowing reasonable use of sites subject to hillside regulations. The applicant’s clear and substantiated evidence includes: a. Building elevations and section drawings showing the structure’s location relative to the average natural grade of the site, and how the project keeps a low profile, including when viewed from a public view at a higher elevation (Terrace Hill Open Space). The requested height of the retaining walls is necessary for the structure to demonstrate this low profile, minimize the overall building footprint, and minimize Resolution No. PC-1011-20 1141 Ella Street, APPL-0233-2020 Page 3 additional grading further up the hillside for the single-family residence. b. Maneuverability and parking studies showing sufficient area for vehicles to exit the site in a forward direction while keeping the structure as close to the street as possible. c. Exhibits and renderings showing the structure as it will be seen from the public right of way (Ella Street) during the Architectural Review Hearing. d. Exhibits showing how the project will relate to neighboring properties and structures regarding solar exposure, shading, neighboring viewsheds, and privacy impacts during the Architectural Review Hearing. e. Grading and drainage documents reviewed by the City’s Community Development Engineering Division that show the project can meet all applicable engineering standards. 7. Zoning Regulations Section 17.70.090(D) allows for the Director to consider and grant exceptions to Hillside Development Standards subject to additional findings. The proposed exceptions to allow portions of downhill building walls to exceed 15 feet in height and to allow retaining walls up to 12 feet in height are supported based on the following findings: a. The project complies with and furthers the intent of the Hillside Development section of the Zoning Regulations because the design preserves the scenic hillside and the City’s scenic setting by keeping the massing of the building at a low elevation against the backdrop of Terrace Hill; avoids encroachment into sensitive habitats or unique resources as defined in the Conservation and Open Space Element; and protects the health safety and welfare of community residents by directing development away from areas with hazards such as landslides, wildland fires, flooding, and erosion by minimizing the building footprint and keeping the floor area of upper stories above the lower foundations. Setting the upper stories further back would require expanding the foundation to an area further up the hillside. b. The project provides a design solution that is equivalent to or better than the standards prescribed in this Hillside Development Section for quality, effectiveness, durability, and safety because the building wall exception allows for the upper floors of structure to be located closer to the street and allows for a building footprint of only 22%, which reduces its impact to the site, and the retaining wall exception facilitates code compliance for driveway slope and egress. c. The location and design of the features receiving the exception will minimize impacts to scenic resources and will not hinder opportunities for wildlife habitation, rest, and movement because the exception allows for the building to occupy a smaller footprint and to keep the massing of the structure at a low elevation against Resolution No. PC-1011-20 1141 Ella Street, APPL-0233-2020 Page 4 the backdrop of Terrace Hill, and closer to existing urban residential development. d. The exception will not prevent the implementation of City-adopted plans, nor increase the adverse environmental effects of implementing such plans, as the project is limited to residential development on a residential lot, within an existing residential neighborhood consistent with the General Plan. e. There are circumstances applying to the site, such as size, shape, or topography, which do not apply generally to land in the vicinity with the same zoning, that would deprive the property of privileges enjoyed by other property in the vicinity with the same zoning because the site is one of only two flag lots along this section of Ella Street that is below Terrace Hill. f. The exceptions will not constitute a grant of special privilege (an entitlement inconsistent with the limitations upon other properties in the vicinity with the same zoning) because the other sloped flag lot on this section of Ella Street below Terrace Hill are developed with downhill building walls exceeding 15 feet and the retaining wall exception facilitates compliance with code requirements for driveway slope and egress. g. The exceptions will not be detrimental to the public welfare or injurious to other property in the area of the project, because the project has been reviewed for code compliance for building and engineering standards, including drainage, and will not adversely impact neighboring properties’ available solar exposure or visual privacy. h. A redesign of the project would deny the property owner reasonable use of the property because the other flag lot along this section of Ella Street is developed with a single-family residence of comparable size (square footage), on a smaller lot, with similar design aspects that would require exceptions under the current Zoning Regulations, and reasonable use of the subject property would allow for similar development. SECTION 2. Environmental Review. The project is categorically exempt from environmental review (Class 3, Section 15303, New Construction or Conversion of Small Structures, State CEQA Guidelines) because the project consists of the construction of one single- family residence and attached accessory dwelling unit within the Medium-Density Residential zone. SECTION 3. Action. The project conditions of approval do not include mandatory code requirements. Code compliance will be verified during the plan check process, which may include additional requirements applicable to the project. The Planning Commission (PC) hereby grants final approval to the project with incorporation of the following conditions: Planning Division Resolution No. PC-1011-20 1141 Ella Street, APPL-0233-2020 Page 5 1. A building plan check submittal that is in substantial conformance with submitted project plans and the following conditions of approval shall be submitted for review and approval of the Community Development Department. A separate, full-size sheet shall be included in working drawings submitted for a building permit that lists all conditions of project approval for ARCH-0816-2019. Reference shall be made in the margin of listed items as to where in plans requirements are addressed. Any change to approved design, colors, materials, landscaping, or other conditions of approval must be approved by the Community Development Director. 2. Plans submitted for a building permit shall call out the colors and materials of all proposed building surfaces and other improvements on elevation drawings dated January 16, 2020. 3. A final landscaping plan, including irrigation details and plans, shall be submitted to the Community Development Department along with the building permit application. The legend for the landscaping plan shall include the sizes and species of all groundcovers, shrubs, and trees with corresponding symbols for each plant material showing their specific locations on plans. All planting shown on the approved landscaping plan shall be installed prior to the release of occupancy. 4. The locations of all lighting, including bollard-style landscaping or path lighting, shall be included in plans submitted for a building permit. All wall-mounted lighting fixtures shall be clearly called out on building elevations included as part of working drawings. All wall- mounted lighting shall complement building architecture. The lighting schedule for the building shall include a graphic representation of the proposed lighting fixtures and cut- sheets on the submitted building plans. The selected fixture(s) shall be shielded to ensure that light is directed downward consistent with the requirements of the City’s Night Sky Preservation Standards contained in Chapter 17.23 of the Zoning Regulations. Engineering/Public Works 5. The building permit plan submittal shall show and label the existing and proposed property lines and all existing and new survey monumentation for reference. Building and site improvements shall clarify how property corners and lines are established to the satisfaction of the City and architect/engineer of record. 6. The building plan submittal shall reference the Common Driveway Agreement per document number 1997-048520. 7. The building plan submittal shall show and label all existing and proposed private and public easements. 8. The building plan submittal shall show on the plans that the current 4-foot wide Americans with Disabilities Act (ADA) compliant disabled access sidewalk meets City and ADA standards or add a note that the ADA disabled access sidewalk shall be altered or replaced Resolution No. PC-1011-20 1141 Ella Street, APPL-0233-2020 Page 6 per City standard. Projects involving the substantial remodel of existing structures requires that complete frontage improvements be installed or that existing improvements be upgraded per city standard (refer to MC 12.16.050). The current driveway appears to meet the current city and ADA standard. 9. Any sections of damaged or displaced curb, gutter and sidewalk affected by construction activities shall be repaired or replaced by the applicant to the satisfaction of the Public Works Department. 10. The building permit application shall include the required Post Construction Requirements (PCR) checklist to show compliance with any pertinent standards. The checklist is available at the following link: http://www.slocity.org/home/showdocument?id=5190. 11. The building plan submittal shall include a complete grading and drainage plan and drainage calculations prepared by a registered or licensed professional. The submittal shall show the existing and proposed contours and spot elevations to clearly depict the proposed grading and drainage. The submittal shall show and label the high point elevation or grade break at the yard areas and drainage arrows to show drainage. The submittal shall include the finished floor (FF) of the residence/garage, patio finish surface elevation, finish grade elevations and yard drainage. 12. The grading and drainage plan shall show and label existing structures and grades located within 15 feet of the property lines in accordance with the grading ordinance. The plan shall consider historic offsite drainage tributary to this property that may need to be accepted and conveyed along with the improved on-site drainage. Any improved or altered drainage shall be directed to the street and not across adjoining property lines unless the drainage is conveyed within recorded easements or existing waterways. 13. The project drainage report and plans shall include analysis of the run-on from Terrace Hill. The plans shall show how the tributary run-on will be collected and conveyed in a non- erosive manner. The plans shall include provisions for a safe overflow. Sheet flow shall not over top the proposed 2:1 cut slope, unless otherwise approved by the soils engineer and the project engineer. The plans shall clarify whether a brow ditch, short wall, or other improvement is necessary to accept and convey the run-on. No work shall be completed within or needing access to or construction staging within the City owned parcel/Open Space. 14. The building plan submittal shall show compliance with the building code and grading ordinance for top of slope setbacks from side yard and rear yard property boundaries. 15. A CAL-OSHA permit is required for excavations or trenching greater than 5 feet in depth. A copy of the annual, provisional, or temporary permit shall be provided to the Building Division prior to building, utility, and/or grading permit issuance if applicable (refer to California Health and Safety Code Section 17922.5). 16. The building submittal shall include a complete site utility plan. The utility plan shall show all existing and proposed on-site and off-site utilities. The submittal shall show the location Resolution No. PC-1011-20 1141 Ella Street, APPL-0233-2020 Page 7 of all overhead and underground utilities along with the location of any utility company meters. The submittal shall show all existing and proposed improvements located within the public right-of-way and within the existing private/common driveway, if applicable. The submittal shall include reference to the permit number that authorized the construction and inspections for all existing improvements serving this parcel. 17. New wire utility services including electrical service, phone, and cable TV shall be placed underground at the expense of the applicant. The undergrounding of utilities shall be completed without a net increase in the number of required wood utility poles. 18. The existing or new water service(s) and water meters shall be sized in accordance with the approved fire sprinkler plans. The building plan submittal shall clearly label the size of the existing service, meter vault, and service piping from the meter to the residence for reference. 19. The site development plan, foundation/wall plans, and utility plans shall limit the amount of disturbance within the root zone/tree canopy of the trees to remain. Tree protection measures shall be implemented by the applicant to the satisfaction of the City Arborist. The City Arborist shall review and approve the proposed tree protection measures to be incorporated into the building plans. A pre-construction meeting with the City Arborist shall be scheduled prior to building demolitions, tree removals, site grading, wall construction, and building construction. Fire 20. The accessory dwelling unit shall be separated from the main home by a 1-hour fire rated separation both vertically and horizontally. Windows shall not be communicated between the two unless specifically rated. Utilities 21. The construction plans shall show any existing or proposed utility easements for water and sewer services from 1131 Ella Steer within the driveway. 22. The proposed landscape plan shall include maximum allowed water allowance (MAWA) and estimated total water use (ETWU) calculations per the formula found on the City’s website: http://www.slocity.org/government/department-directory/utilities-department/documents- and-files Please include the calculation table within the plan set. Indemnification 23. The applicant shall defend, indemnify, and hold harmless the City and/or its agents, officers, and employees from any claim, action, or proceeding against the City and/or its agents, officers, or employees to attack, set aside, void, or annul the approval by the City of this project, and all actions relating thereto, including, but not limited to, environmental review (“Indemnified Claims”). The City shall promptly notify the applicant of any Indemnified Resolution No. PC-1011-20 1141 Ella Street, APPL-0233-2020 Page 8 Claim upon being presented with the Indemnified Claim and the City shall fully cooperate in the defense against an Indemnified Claim. On motion by Commissioner Kahn, seconded by Commissioner Wulkan, and on the following roll call vote: AYES: Commissioners Hopkins, Kahn, Quincey, Shoresman, Wulkan, Vice-Chair Jorgensen and Chair Dandekar NOES: None REFRAIN: None ABSENT: None The foregoing resolution was passed and adopted this 24th day of June 2020. _____________________________ Brian Leveille, Secretary Planning Commission