Loading...
HomeMy WebLinkAboutItem 5j. Attachment A - CADPS Phase 1A PlansetReference Documents:City Standard Specifications - August 2020 EditionCity Engineering Standards - August 2020 Edition1.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR ORPERMITTEE TO CONTACT "UNDERGROUND SERVICE ALERT OFNORTHERN CALIFORNIA" BY PHONE AT 8-1-1 FORTY-EIGHT (48)HOURS PRIOR TO START OF CONSTRUCTION FOR LOCATION OFPOWER, TELEPHONE, OIL AND NATURAL GAS UNDERGROUNDFACILITIES. CONTRACTOR OR PERMITTEE SHALL ALSOCONTACT THE APPROPRIATE AGENCY FOR THE LOCATION OFCABLE T.V., WATER, SEWER, DRAINAGE OR UNDERGROUNDFACILITIES.2.THE CONTRACTOR SHALL POSSESS A CLASS C-10 LICENSE ATTHE TIME OF BID OPENING.index to planssheet no.descriptiongeneral notes:san luis obispo county, californiascope of work:Cultural Arts District ParkingStructure - Phase 1ADry Utility Undergrounding1VICINITY MAP, GENERAL NOTES2GENERAL NOTES, VICINITY MAP3DRY UTILITY PLAN4ELECTRICAL DETAILSAPPROVED BYSPECIFICATION NO.DATEofSHEETBrian Nelson, City Engineer R.C.E. C79870 Approved Date4June 202290435-1A1FILE NO./LOCATIONPROJECTLOCATION1.New dry utility service conduits to serve existing building to remain alongthe Broad, Nipomo, Monterey block.2.Trenching in existing right of ways, new pull boxes, transormer pad, andpole riser sweeps.3.Utility providers to disconnect existing services, remove unused cables,supply new service cables, and make all final terminations as necessary.location map OTTO ELECTRICAL, INC. SAN LUIS OBISPO, CA GOTTO@OTTOELECTRICAL.COM 805.459.4329 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATIONCultural Arts District Parking Structure - Phase 1ADry Utility UndergroundingGO GO BN BN PER PLANS JUNE 2022 90435-1A 4 Know what's below. before you dig.Call R 2 GENERAL NOTES, VICINITY MAPPROJECT LOCATION GENERAL NOTES 1.CODE COMPLIANCE: ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH CODES, STANDARDS, AND ORDINANCES AS SET FORTH BY THE AUTHORITIES HAVING JURISDICTION AND THEIR LATEST ADOPTED EDITIONS (IN EFFECT AT TIME OF BUILDING PERMIT APPLICATION) OF THE FOLLOWING PUBLICATIONS: A.CALIFORNIA CODE OF REGULATIONS TITLE 24; INCLUDES 2019 CALIFORNIA ELECTRICAL CODE, 2019 CALIFORNIA FIRE CODE, 2019 CALIFORNIA BUILDING CODE, ETC. WITH LOCAL AMENDMENTS AS APPLICABLE. B.AMERICANS WITH DISABILITIES ACT (ADA). 2.SAFETY: THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN A SAFE AND RESPONSIBLE MANNER. KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED. CONDUCT ALL CONSTRUCTION OPERATIONS IN A SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER WORKPERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS, FLAGS, TAPE, ETC. AS REQUIRED FOR SAFETY. THE CONTRACTOR SHALL HOLD ALL PARTIES HARMLESS OF NEGLIGENT SAFETY PRACTICES, WHICH MAY CAUSE INJURY TO OTHERS ON OR NEAR THE JOB SITE. 3.LABEL PANELS, CABINETS, BACKBOARDS, MAIN DEVICES, SAFETY SWITCHES, CONTACTORS AND OTHER SPECIFICALLY DESIGNATED EQUIPMENT SHOWN ON PLANS. USE ENGRAVED LAMINATED PLASTIC NAMEPLATES ATTACHED BY SCREWS OR RIVETS. FOR FEEDERS, NEATLY AND INDELIBLY LABEL CONDUIT DESTINATIONS ON BOTH VISIBLE ENDS OF CONDUIT RUNS WHERE CONDUITS TERMINATE AT DESIGNATED ENCLOSURES, STRUCTURES OR EQUIPMENT (INCLUDING PULL AND SPLICE BOXES). GENERAL SITE PLAN NOTES A.ALL UTILITY WORK AND COORDINATION SHALL BE INSTALLED PER THE UTILITY COMPANY ISSUED CONSTRUCTION DRAWINGS AND SPECIFICATIONS SPECIFIC TO THIS PROJECT. ANY UTILITY WORK PERFORMED WITHOUT PRIOR UTILITY COMPANY APPROVAL SHALL BE DONE AT THE CONTRACTOR'S RISK. PG&E APPLICATIONS HAVE BEEN INITIATED BY ENGINEER: PG&E ELECTRIC & GAS SERVICE REQUIREMENTS - GREENBOOK 2020-2021 051122 - CLEARANCES AND LOCATION REQUIREMENTS FOR ENCLOSURES, PADS, AND UNDERGROUND EQUIPMENT. 062288 - UNDERGROUND CONDUIT. NOTIFICATION NUMBER: 11839790 PM NUMBER: 35323721 B.UTILITY COMPANY CONTACTS: BEFORE CONSTRUCTION, COORDINATE & VERIFY ALL UTILITY COMPANY REQUIREMENTS: PG&E - JUSTIN MCDONALD, JUSTIN.MCDONALD@PGE.COM, 805.546.1271 C.TRENCHING AND BACKFILLING FOR ALL CONDUIT SYSTEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL CONDUITS SHALL HAVE MINIMUM COVER REQUIREMENTS AS SPECIFIED IN CEC 300-5 AND PER CITY STANDARDS. MORE STRINGENT DEPTH REQUIREMENTS MAY BE IMPOSED BY UTILITY COMPANY AND / OR THIS SPECIFICATION. JOINT TRENCHING MAY BE UTILIZED WHERE PRACTICABLE AND WHERE PERMITTED BY THIS SPECIFICATION. D.LOCATIONS OF EXISTING UNDERGROUND (UG) UTILITY SYSTEMS SHALL BE DETERMINED BY CALLING UNDERGROUND SERVICE ALERT (USA). WHEN PLANNING UNDERGROUND WORK, AND BEFORE YOU DIG, CONTACT UNDERGROUND SERVICE ALERT (USA) AT LEAST 48 HOURS PRIOR TO EXCAVATION (WEEKENDS EXCLUDED) FOR THE LOCATION OF UNDERGROUND GAS AND ELECTRIC LINES OR EQUIPMENT. E.MAINTAIN REQUIRED CLEARANCES FROM ALL SANITARY SEWER, WATER AND STORM DRAIN PIPING PER CITY STANDARD 6010. F.ALL SITE UTILITY WORK SHALL BE INSTALLED PER THE UTILITY COMPANY ISSUED CONSTRUCTION DRAWINGS AND SPECIFICATIONS SPECIFIC TO THIS PROJECT. ANY UTILITY WORK PERFORMED WITHOUT PRIOR UTILITY COMPANY APPROVAL SHALL BE DONE AT THE CONTRACTOR'S RISK. VICINITY MAP NOT IN CONTRACT ON CENTER NOT TO SCALE NORMAL POWER FACTOR NORMALLY OPEN NIGHT LIGHT MAIN CIRCUIT BREAKER MAIN FUSIBLE SWITCH LOW VOLTAGE LOW PRESSURE SODIUM MAXIMUM OCP MINIMUM CKT AMPS LOCKED ROTOR AMPS QUANTITY 1000 MAIN CATV TERMINAL CABINET MANUAL TRANSFER SWITCH NATIONAL ELECTRICAL CODE LIFE SAFETY BRANCH MAIN TELEPHONE TERMINAL CABINET NEUTRAL (GROUNDED CONDUCTOR) NAT'L ELEC MANUFACTURER'S ASSOC NORMALLY CLOSED MICROWAVE MAIN TELEPHONE TERMINAL BOARD MAIN SWITCHBOARD MAIN LUGS ONLY MOUNTING HEIGHT METAL HALIDE MANUFACTURER MECHANICAL MAIN CATV TERMINAL BOARD MECHANICAL CONTRACTOR LIGHTING CONTACTOR KILOVOLTAMPS NEMA 3R MOUNT LIGHTING LIGHT KILOWATT NPF(F)FUTURE FA F-# FIRE ALARM FURNACE OC NTS CURRENT TRANSFORMER CALIFORNIA SFM CONDUIT, CONDUCTOR CONDUIT ONLY (W/PULLROPE) CRITICAL BRANCH COPPER CONDENSING UNIT CONTRACTOR CIRCUIT CENTER LINE EM ES (EXR) EXT (EXN) F EMB EQUIP'T EMERG EOL EC-# EL EM ELEC EF-# EB EC EA (E) CU-# DW DISC DIST DPST DF DIA DC D COND CSFM CT Cu CR C.O. CKT CNT'R CL MHEMERGENCY FLUORESCENT EMERGENCY BALLAST (E) TO BE (R) (E) IN (N) LOCATION ENERGY SAVING EXTERIOR EMERGENCY END OF LINE EQUIPMENT EVENING LIGHT EMERG BATTERY BACKUP ELECTRONIC BALLAST EVAPORATIVE COOLER ELECTRICAL CONTRACTOR ELECTRICAL EXHAUST FAN EXISTING EACH NEC NIC NO NL NEMA N N3R NC (N)NEW MT HT MTTC MTTB MTS MW MOCP MSB MLO MT DOUBLE POLE SINGLE THROW DRINKING FOUNTAIN DIRECT CURRENT DISHWASHER DISTRIBUTION DISCONNECT DIAMETER DEPTH LV MCTC MECH MFS MFR MCTB MCB MCA MC LPS LS LTG LT LRA LC kW kVA k WEATHERPROOF (NEMA 3R)WP INDICATES MOUNTING HEIGHT AFF TRANSFORMER +48 XFMR TIME SWITCH OVERRIDE TWISTED SHIELDED PAIR VANDAL-RESISTANT UNDERWRITERS LABORATORIES SINGLE POLE SINGLE THROW TYPICAL SIMILAR TELEPHONE TERMINAL CABINET VERY HIGH OUTPUT TRANSFORMER, TERMINAL WATER HEATER WIDTH, WATT, WIRE VOLT ALTERNATING CURRENT VOLT AMPERES UG SVC ALERT 800-642-2444 UNLESS OTHERWISE NOTED UNDERGROUND PULL SECTION UNDERCABINET, UNDERCOUNTER TELEPHONE TERMINAL BOARD TELEPHONE COMPANY TO BE REMOVED TELEPHONE CONDUIT SLIMLINE, SWITCH LEG VOLTAGE UNDERGROUND TIME CLOCK TRANSFORMER TIME SWITCH TELEPHONE SURFACE STORAGE SPECIFICATION TTB WH-# USA VHO VAC VOLT VR W VA V VOLT UON UGPS TYP SIM TTC TYP UC UL UG TX TYPICAL T TSP TSO TELCO TEL (TBR) -T- TS TC SURF SVC SPST STR'G SPEC SHT SQ SW SL SQUARE SWITCH SERVICE SHEET HIGH INTENSITY DISCHARGE FIRE ALARM CONTROL PANEL HAND-OFF-AUTO INSIDE FROST IDENTIFICATION HIGH OUTPUT ISOLATED GROUND JUNCTION BOX HORSEPOWER HIGH PRESSURE SODIUM HIGH POWER FACTOR INTERCOM FULL VOLTAGE NON-REVERSING HEATING, AC & REFRIG FULL LOAD AMPS FUSIBLE SWITCH FURNISHED BY OTHERS HEIGHT, HIGH GANG WITH SWITCH GALVANIZED RIGID STEEL GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT CIRCUIT INTERRUPTER GARBAGE DISPOSAL GENERAL CONTRACTOR GROUNDING CONDUCTOR FLUORESCENT FORCED AIR UNIT FIRE ALARM TERMINAL GROUND FLOOR FAN COIL CONDUIT CALIFORNIA FIRE CODE CA. BUILDING CODE CA. ENERGY COMMISSION COMPACT FLUORESCENT CABINET CEILING CA. ELECTRICAL CODE CIRCUIT BREAKER, CODE BLUE CATV CONDUIT CABLE TELEVISION AUTOMATIC TIME SWITCH AMERICAN WIRE GAGE AUTOMATIC TRANSFER SWITCH AMP BREAKER AUDIBLE/AUDIO VISUAL ALUMINUM AMP SWITCH RATING AMPERES INTERRUPTING CAPACITY ABOVE FINISH GRADE ABOVE FINISH FLOOR AMP FUSE, AMP FRAME ALTERNATING CURRENT AIR CONDITIONER ABOVE ABANDONED AMPERE ABBREVIATIONS ADJACENT AS -C- CEC CFC CF CLG CBC CAB'T CATV CB BIL BLDG BFG C AV AWG ATS ATS AF AFG AIC AFF Al AC AC-# ABV ADJ AB ABAND A GD BASIC IMPULSE LEVEL BELOW FINISH GRADE BUILDING HO IC J-BOX IF ID IG HOA HPF HPS hp HID HACR GWS H GND GRS GFI GFCI FLUOR FVNR G GC FS FC-# FLA FLR FBO FACP FAU FAT REMOTE TERMINAL UNIT STATE FIRE MARSHAL RATED LOAD AMPS PLANNING & DEVELOPMENT OFFICE of STATEWIDE HEALTH OFFICE of the STATE ARCHITECT POINT OF CONNECTION RIGID METAL CONDUIT PLUMBING CONTRACTOR SHORT CKT CURRENT POWER SECONDARY POWER PRIMARY PUBLIC ADDRESS OUTSIDE DIAMETER REFRIGERATOR OVERCURRENT PROTECTION RAPID START REPLACE REQUIRED PULLBOX PULL CHAIN RECEPTACLE RELOCATE(D) PHOTOCELL OVERHEAD OVERLOAD PC REQ'D RPLC SFM SCC RLA RMC RMV RTU RS RM REMOVE ROOM REF POC -PP- -PS- (R) RECEPT PNL ph PHASE PANEL OSHPD OVLD OSA P PB PC PC PA POLE OCP OH OD PHOTOVOLTAICPV SSSSSSSSSSSSSSSSSS SS SSSS SSSSSS24" OLIVE ATT WVWVSLBPGECTVWMWMWMPGECTVPGEWM ELEC ELEC ICV WVWV WMCATVPGETELGASEM 18" PINE //////////////////8" PINEWVS C OTREE 14"TREE 6"WSPAC BELLC O CO ICVICV18" TREE 1 8 " T R E E 1 0 " O A K 8" T R E E18" EUK 2 6 " E U K 16" TR E E 36" TR E E 28" TR E E 24" PIN E 26" PINE TRASH 10" PINE 12" OAK UTIL2P TREE 12" & 6"///3P TREE36" BASE ///////////////////////////WLWLWLWLWLWLWLWLWLWLWLWLWL14" TREE6" TREE40" TREEC O 10" TREE CO 4" TREE TEL TRASHICV 12" TREE CTVUTILUTILWM WV14" TREE1 0 " T R E E WVWVWVUTIL UTILWMGASS 16" TREE 8" 3P TREE 8" & 14" 2P TREE WM WM PAC BELL WM 1 4 " O A K 1 2 " T R E E22" TREEPLANTER40" TREE WVwTRASH PG&E PAD MOUNT TRANSFORMER 50"X52" PAD AND PROTECTIVE BOLLARDS PER PG&E REQUIREMENTS EXISTING PG&E POLE CHARTER TIE IN AT EXISTING VAULT AT WEST SIDE BROAD ST. RELEVEL PULL BOXES AND COVERS TO BE FLUSH WITH NEW SIDEWALK. EXISTING AT&T CONDUIT. PROTECT IN PLACE. PROVIDE NEW ADJACENT AT POLE. PG&E , AT&T, AND CHARTER TO REPLACE EXISTING POLE AND SERVICE DROPS PG&E , AT&T, AND CHARTER TO REPLACE OVERHEAD SERVICE CABLES. CHARTER PULL BOX. 2'X3' AT&T PULL BOX. 17"X30" REMOVE AND REPLACE EXISTING CURB, GUTTER, AND SIDEWALK PER CITY STANDARD 4220. SALVAGE GRANITE CURB TO CITY CORPORATION YARD AS DIRECTED BY THE ENGINEER (285 SQ. FT) AT&T TIE IN AT EXISTING VAULT AT WEST SIDE BROAD ST. RELEVEL PULL BOXES AND COVERS TO BE FLUSH WITH NEW SIDEWALK. REMOVE AND REPLACE EXISTING CURB, GUTTER, AND SIDEWALK PER CITY STANDARD 4220. SALVAGE GRANITE CURB TO CITY CORPORATION YARD AS DIRECTED BY THE ENGINEER (270 SQ. FT.) INTERCEPT EXISTING PRIMARY CONDUIT AND EXTEND INTO NEW PG&E VAULT. COORDINATE WORK WITH PG&E. EXISTING PG&E VAULT C 4 B 4 A 4 190LF 170LF 160LF 32'± 9'± PROTECT IN PLACE ROCK WALL PROVIDE 12" CLEARANCE TO GAS LINES. PROVIDE 12" CLEARANCE TO GAS LINES. REMOVE EXISTING LANDSCAPING 37'± 8'± REPLACE HI-VIS CROSSWALK PER CITY STANDARD 7350 REMOVE EXISTING PARKING METERS REMOVE AND REPLACE EXISTING CURB, GUTTER, AND SIDEWALK PER CITY STD. 4220. ADJUST UTILITY BOXES TO FINISHED SURFACE. PAINT CURB RED. (88 SQ. FT.) 11'± 8'± REPLACE HI-VIS CROSSWALK PER CITY STANDARD 7350 4" SPARE CONDUIT STUBBED INTO PLANTER AREA FOR FUTURE USE. 975 696 680 664658 PROPERTY LINE (TYP) NORTH SCALE: DRY UTILITY PLAN - BROAD AND MONTEREY STREET 1" = 20'-0" OTTO ELECTRICAL, INC. SAN LUIS OBISPO, CA GOTTO@OTTOELECTRICAL.COM 805.459.4329 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATIONCultural Arts District Parking Structure - Phase 1ADry Utility UndergroundingGO GO BN BN PER PLANS JUNE 2022 90435-1A 4 Know what's below. before you dig.Call R LEGEND #5 PG&E ENCLOSURE 3'X5'X3'6" INSTALLED BY CONTRACTOR PG&E CODE 025601 SPLICE BY PG&E #6 PG&E ENCLOSURE 4'X6'6"X5' INSTALLED BY CONTRACTOR PG&E CODE 041495 JAY BY PG&E EXISTING DRY UTILITY VAULT/BOX TO REMAIN. PROTECT IN PLACE. REPAIR AND REPLACE LID IF DAMAGED. 1-4" CONTRACTOR INSTALLED DUCT. PG&E INSTALLED 2-1/0A EPE-CONC-ENCAP 1-4" CONTRACTOR INSTALLED DUCT. PG&E INSTALLED 3-1/0A EPE-CONC-ENCAP 1-5" CONTRACTOR INSTALLED DUCT. PG&E INSTALL 750A TPX 1-3" CONTRACTOR INSTALLED DUCT. CHARTER INSTALLED CABLE. 1-4" CONTRACTOR INSTALLED DUCT. AT&T INSTALLED CABLES. EXISTING DRY UTILITY CONDUIT TO REMAIN. PROTECT IN PLACE. EXISTING DRY UTILITY CONDUIT TO BE REMOVED. COORDINATE REMOVAL WITH UTILITY PROVIDER. EXISTING OVERHEAD CABLES EXISTING GAS UTILITY. FIELD LOCATE FOR ADDITIONAL PIPES NOT SHOWN ON DRAWING. EXISTING WATER LINE. FIELD LOCATE FOR ADDITIONAL PIPES NOT SHOWN ON DRAWING. EXISTING SEWER LINE. FIELD LOCATE FOR ADDITIONAL PIPES NOT SHOWN ON DRAWING. 3 DRY UTILITY PLANGENERAL NOTE A.ANY STRIPING AND PAVEMENT MARKINGS REMOVED WITHIN THE LIMITS OF WORK MUST BE REPLACED. B.ROUTING OF NEW UTILITIES ARE ONLY A SUGGESTION. NOT ALL UTILITIES ARE SHOWN. DRY UTILITIES SUCH AS CATV, TELEPHONE, FIBER, AND POWER ARE LOCATED WITHIN THE PROJECT AREA. CONTRACTOR SHALL LOCATE EXISTING UTILITIES PRIOR TO STARTING WORK, CONTRACTOR SHALL ADJUST ROUTING TO AVOID EXISTING UTILITIES AND MAINTAIN CLEARANCES PER MOST RESTRICTIVE UTILITY STANDARDS/REQUIREMENTS. C.NOT ALL LATERALS ARE SHOWN ON PLANS. LOCATING LATERALS IS THE RESPONSIBILITY OF THE CONTRACTOR AND ANY DAMAGE TO A LATERAL MUST BE REPAIRED IMMEDIATELY AND AT NO COST TO THE CITY. D.ARCHEOLOGICAL MONITORING REQUIRED FOR TRENCHING WITHIN BROAD AND MONTEREY. TRACER WIRE WARNING TRACER TAPE 2" MIN ~9" MIN REFER TO CITY STANDARD DETAILS 6010, 6020, 6030, 6040 FOR ADDITIONAL TRENCH AND LOCATION REQUIREMENTS. _ 12" MAX P2 4" MIN BACKFILL TRENCH PER CITY STANDARD 6035 *NOTE: BROAD AND MONTEREY IS PAVED WITH AC OVER PCC. AC OVER PCC PAVEMENT RESTORATION PER CITY STANDARD 4110 AND 6020 36" BELOW CROSSING UTILITIES OR 84" BELOW TOP OF CURB, WHICHEVER IS DEEPER WARNING TRACER TAPE 2" MIN ~13" MIN REFER TO CITY STANDARD DETAILS 6010, 6020, 6030, 6040 FOR ADDITIONAL TRENCH AND LOCATION REQUIREMENTS. _ 12" MAX S1 4" MIN TRACER WIRE T4 12" MIN C2 2" MIN TEE CUT WITH THE WIDTH OF THE AC CUT EXTENDED ONE FOOT EACH SIDE OF TRENCH. 6' AC TO BE CONSTRUCTED BY PLACING 4" THICK AC (1/2" AGGREGATE), PAVING GRID (GLASGRID 8502, STARGRID G-PS 200-100, OR APPROVED EQUAL) AND 2" AC THICK SURFACE COURSE (1/2" AGGREGATE) BACKFILL TRENCH PER CITY STANDARD 6035 36" BELOW CROSSING UTILITIES OR 84" BELOW TOP OF CURB, WHICHEVER IS DEEPER WARNING TRACER TAPE 2" MIN ~13" MIN REFER TO CITY STANDARD DETAILS 6010, 6020, 6030, 6040 FOR ADDITIONAL TRENCH AND LOCATION REQUIREMENTS. _ 12" MAX 4" MIN TRACER WIRE T4 C2 2" MIN BACKFILL TRENCH PER CITY STANDARD 6035 TRENCHING WITHIN STREET SECTION PER CITY STANDARD 6020 CASE 2. *NOTE: BROAD AND MONTEREY IS PAVED WITH AC OVER PCC. AC OVER PCC PAVEMENT RESTORATION PER CITY STANDARD 4110 AND 6020 36" BELOW CROSSING UTILITIES OR 84" BELOW TOP OF CURB, WHICHEVER IS DEEPER OTTO ELECTRICAL, INC. SAN LUIS OBISPO, CA GOTTO@OTTOELECTRICAL.COM 805.459.4329 CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATIONCultural Arts District Parking Structure - Phase 1ADry Utility UndergroundingGO GO BN BN PER PLANS JUNE 2022 90435-1A 4 Know what's below. before you dig.Call R 4 ELECTRICAL DETAILSATRENCH SECTION B DETAIL NTS TRENCH SECTION A DETAIL SCALE:NTSB TYPICAL BOLLARD DETAIL1NTS NOTE: EXACT LOCATIONS OF PIPE BOLLARDS SHALL BE FIELD COORDINATED AND LOCATED AROUND EQUIPMENT SO THAT DOORS FULLY OPEN AND WORKING CLEARANCES ARE PRESERVED.3" 12" 32" 42" UNREINFORCED CONCRETE FOOTING FINISHED GRADE 4" DIAMETER STEEL POST FILLED WITH CEMENT GROUT, PAINT EXTERIOR SURFACE OF POST YELLOW. REFLECTIVE TAPE (TYPICAL) SCALE: TRENCH SECTION C DETAIL NTSCSCALE: 6" GROUT 24"-36" CRUSHED ROCK SUMP (18" MIN DEPTH) BELL END 2" DIA DRAIN6"HOLE FINISHED GRADE REINFORCED CONCRETE OR POLYMER COVER (TO SUIT APPLICATION). LABEL COVER PER UTILITY REQUIREMENTS. PRECAST REINFORCED CONCRETE OR POLYMER CONCRETE BOX. SIZE PER PLANS. SEAL AROUND CONDUIT, BOX AND EXTENSION JUNCTION. PRECAST REINFORCED EXTENSION #15 ROOFING PAPER BETWEEN GROUT AND CRUSHED ROCK 2 TYPICAL AT GRADE PULL BOX DETAIL SCALE:NTS *TRENCH DEPTH NOTE: DEPTH OF CONDUITS ARE SHOWN AS MINIMUMS. IN ORDER TO AVOID OTHER UTILITY CROSSINGS THAT THE DEPTH OF TRENCH MAY NEED TO BE INCREASED TO PROVIDE SUFFICIENT CLEARANCE BELOW EXISTING UTILITIES AS DIRECTED BY THE ENGINEER.