HomeMy WebLinkAboutInspection Report - 1301 Calle JoaquinCity of San Luis Obispo Fire Department 2160 Santa Barbara Avenue San Luia Obispo, CA 93401 805R81-7380 Occupant Name: TownePlace Suites by Marriott Inspection Date: 2/18/2022 Address: 1301 Calle Joaquin InspectionType: Annual Fire Business Inspection City: San Luis Obispo Inspected By: Jason Beres 805/594-8021 jberes@slocity.org Suite: Insp. Result Parcel/Tax ID #: Location Code Set 053-152-003 Pass 2019 California Fire Code CHAPTER 3 GENERAL REQUIREMENTS Code 304.1 - Waste accumulation prohibited. Pass 2019 California Fire Code 304.1.2 - Vegetation Abatement CHAPTER 3 GENERAL REQUIREMENTS Pass 2019 California Fire Code 304.3.1 - Spontaneous ignition. CHAPTER 3 GENERAL REQUIREMENTS Pass 2019 California Fire Code 304.3.3 - Dumpsters CHAPTER 3 GENERAL REQUIREMENTS Pass 2019 California Fire Code 310.3 -"No Smoking" signs. CHAPTER 3 GENERAL REQUIREMENTS Pass 2019 California Fire Code 315.1 -General Storage CHAPTER 3 GENERAL REQUIREMENTS Pass 2019 California Fire Code 503.3 - Fire Lane Marking CHAPTER 5 FIRE SERVICE FEATURES Pass 2019 California Fire Code CHAPTER 5 FIRE SERVICE FEATURES 503.4 - Obstruction of fire apparatus access roads. Pass 2019 California Fire Code 504.4 - Roof access. CHAPTER 5 FIRE SERVICE FEATURES Pass 2019 California Fire Code 505.1 - Address identification. CHAPTER 5 FIRE SERVICE FEATURES Fail 2019 California Fire Code 506.1 - Key box required. CHAPTER 5 FIRE SERVICE FEATURES Inspector Comments: Provide keys for the knox-box installed at the main entrance of this building. Keys should include access the following locations: main electrical room, fire sprinkler riser room, main building entrance, common hallway access doors. Pass 2019 California Fire Code 603.1 - Installation/storage of fuel -fired appliances CHAPTER 6 BUILDING SERVICES AND SYSTEMS Pass 2019 California Fire Code CHAPTER 6 BUILDING SERVICES AND SYSTEMS 604.3 - Clearance around electrical service equipment. Pass 2019 California Fire Code CHAPTER 6 BUILDING SERVICES AND SYSTEMS 604.3.1 - Electrical labeling for firefighters Pass 2019 California Fire Code 604.5 - Extension cords. CHAPTER 6 BUILDING SERVICES AND SYSTEMS Pass 2019 California Fire Code 604.4 - Multiplug adapters. CHAPTER 6 BUILDING SERVICES AND SYSTEMS N/A 2019 California Fire Code 607.3.3 - Cleaning flammable grease CHAPTER 6 BUILDING SERVICES AND SYSTEMS N/A 2019 California Fire Code CHAPTER 6 BUILDING SERVICES AND SYSTEMS 607.3.3.1 - Inspecting flammable grease systems 2019 California Fire Code Pass CHAPTER 7 FIRE AND SMOKE PROTECTION 705.1 - Maintenance of opening protectives FEATURES 2019 California Fire Code Fail CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY 903.1 -Automatic sprinkler system compliance SYSTEMS Inspector Comments: Note: City records indicate that construction permit No. 4096-2019 has not been finalized and is missing the following information: NFPA 13 Aboveground Test Certificate, NFPA 24 Underground Test Certificate, and main drain flow test. Please coordinate obtaining the following documentation noted above with the project manager assigned to this construction project. Note: Hydraulic calculations plates not installed on the fire sprinkler riser or standpipe systems for this building as noted during inspection. Please coordinate with the fire protection contractor to confirm that this information has been installed prior to requesting main drain flow test for each system. City records indicate that this test has not been completed for this building. An inspection for the conditions noted above can be scheduled by contacting the SLOFD Inspection Line (805) 783-7775. All inspections should be requesting a minimum 48 hours of the requested date and time of inspection. 2019 California Fire Code Pass CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY 906.1 - Portable fire extinguisher installation SYSTEMS 2019 California Fire Code Pass CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY 906.2 - Portable fire extinguisher maintenance SYSTEMS 2019 California Fire Code 906.6 - Portable fire extinguishers must be unobstructed Pass CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY and unobscured. SYSTEMS 2019 California Fire Code 907.6.5 - Access to fire alarm devices for inspection and Pass CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY testing. SYSTEMS 2019 California Fire Code Pass CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY 907.8 - Testing of systems and maintenance of records SYSTEMS 2019 California Fire Code Pass CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY 907.8.5 - Inspection, testing and maintenance. SYSTEMS Pass 2019 California Fire Code 1004.9 - Occupant load signage CHAPTER 10 MEANS OF EGRESS Pass 2019 California Fire Code 1008.2 - Exit signs and emergency lights must be CHAPTER 10 MEANS OF EGRESS operational at all times. Pass 2019 California Fire Code 1010.1.2.1 - Direction of exit door swing. CHAPTER 10 MEANS OF EGRESS Fail 2019 California Fire Code 1010.1.9 - Door operations. CHAPTER 10 MEANS OF EGRESS Inspector Comments: Repair exit door located at the 1 st floor hallway providing access out of the pool area. Door frame found impaired and did not open properly during inspection. Fail 2019 California Fire Code 1010.1.10 - Panic and fire exit hardware. CHAPTER 10 MEANS OF EGRESS Inspector Comments: The hallway exit door leading out into the common pool area was found to be installed without panic hardware (CFC 1010.10). Please contact the project manager associated with the construction for this building and confirm that the exit door hardware has been installed as noted per City permit No. 0844-2017. Inspector Comments: Annual inspection conducted with hotel management staff onsite. Hotel currently issued a temporary certificate of occupancy by City Building Department and pending final inspection. See City construction permit No. BLDG #0844-2017. Note: Hotel manager directed to provide a current hotel safety plan which meets the requirements set forth by CFC 406.4. - CFC 406.4.6. Paperwork to be provided to hotel management for review following initial inspection. Note: The hallway exit door leading out into the common pool area was found to be installed without panic hardware (CFC 1010.10). Please contact the project manager associated with the construction for this building and confirm that the exit door hardware has been installed as noted per City permit No. 0844-2017. Note City records indicate that construction permit No. 4096-2019 has not been finalized and is missing the following information: NFPA 13 Aboveground Test Certificate, NFPA 24 UndergroLind Test Certificate, and main drain flow test. Please coordinate obtaining the following documentation noted above with the project manager assigned to this construction project. Note: Hydraulic calculations plates not installed on the fire sprinkler riser or standpipe systems for this building as noted during inspection. Please coordinate with the fire protection contractor to confirm that this information has been installed prior to requesting main drain flow test for each system. City records indicate that this test has not been completed for this building. An inspection for the conditions noted above can be scheduled by contacting the SLOFD Inspection Line (805) 783-7775. All inspections should be requesting a minimum 48 hours of the requested date and time of inspection. Hotel Management directed to address the following items prior to requesting a follow-up inspection for this building: 1) Provide keys for the knox-box installed at the main entrance of this building. Keys should include access the following locations: main electrical room, fire sprinkler riser room, main building entrance, common hallway access doors. 2) Repair exit door located at the 1 st floor hallway providing access out of the pool area. Door frame found impaired and did not open properly during inspection. 3) Provide signage for main electrical room. Signage should be visible from street view. Upon completion of these three items, please contact the SLOFD Inspection Line (805) 783-7775 to coordinate a follow-up inspection for this property. Inspector will return on or after 3/23/2022 Thank you for your cooperation in keeping your business and our community safe! If you have any questions, please contact us at 805/783-7775. Inspector: Jason Beres, Fire Inspector III 2/18/2022 Ref: 3010