HomeMy WebLinkAboutFrench Hospital_Proposed Site PlanEXISTING DIGNITY HEALTH
FRENCH HOSPITAL
1
EXISTING COPELAND EDUCATIONPAVILLION2
EXISTING LOADINGDOCK3
EMERGENCY DEPARTMENTPROJECT5
EXISTING MEDICAL OFFICEBUILDING6
EXISTING SURFACEPARKING7
NEW CHAPEL & ENTRY TO THE
EXISTINGHOSPITAL9
NEW ACCESSIBLERAMP10
NEW ACCESSIBLEPARKING11
NEW GENERATORYARD12
NEW TRANSFORMER FOR
PATIENT TOWER ELECTRIC
SERVICE
13
PROPERTY LINES TO BE
EXTINGUISHED. PARCELS 3, 4
AND PORTION OF PARCEL 6 TO BE
MERGED WITH PARCEL 2
14
NEW DROP-OFFPLAZA15
LOCATION OF PROPOSED PUBLIC
ART. DESIGN TO BE SUBMITTED
UNDER SEPARATE SUBMITTAL
FOR REVIEW AND APPROVAL AS
REQUIRED BY ZONING CODE
17.70.140
16
NEW VEHICULARRAMP17
OUTDOOR DINING AREA.18
EXISTING LOCKERS AND
SHOWERS FOR EMPLOYEES
PROVIDED ISIDE THE EXISTING
HOSPITAL
19
FIRE DEPARTMENT CONNECTION
AT TOWER
20
NEW PARKING STRUCTURE.
REFER TO PA SHEETS
21
RECONFIGURED SURFACE
PARKING AREA. REFER TO PA
SHEETS
8
RECONFIGURED SURFACE
PARKING. REFER TO PASHEETS22
RECONFIGURED HARDSCAPE AND
LANDSCAPE AREAS. REFER TO PA
SHEETS
23
RECONFIGURED LANDSCAPE
MEDIAN AND PARKING.
24
NEW MEDICALTOWER25
JOHNSON AVE.
ELLA ST.
RAILROAD
TRACKSPROPERTY
LINE LOADING
DOCK
RET.
WALL
12
1110
1
9
5
6 2
3 GROUND
FLOOR FINISH FLOOR
ELEVATION 100'-
0"GROUND
FLOOR FINISH FLOOR
ELEVATION
100'-
0"
13
14 25
14 PARCEL
6 PARCEL
2 PARCEL
3 PARCEL
4 OPEN
SPACE
EASEMENT TO
REMAIN IRISST.OPEN
SPACE
EASEMENT
TO
REMAINBRECK
ST.
1516
17
18
19
7
7
7
7
7 20
A012 1
A011
1 20'
REQUIRED FIRE
LANE
18'-
0"4'-
0"18'-
0"
FIRE
LANE26'-
0" 18'-
0" 4'-0"3'-9"VAN 26' REQUIRED FIRE
LANE 20' FIRE LANE 22 21 20'-
0"2324
2 6'-
0"20'-
0"20'-
0"2
6 '
R
E Q U IR E
D F
IR E
L A N
E
REALIGNED BIKE
PATHDRIVE AISLEGENERATOR
1 GENERATOR 2
FUTURE)
O2 FUEL TANKLANDS CAPELANDSCAPE LANDSCAPE NEW
CURB TO MATCH EXISTING
12 EMERGENCY BACKUP CYLINDERS REFER TO PLUMBING
DRAWINGS 2X2 MANIFOLD WITH DEWARS. REF
TO PLUMBING DRAWINGS BIKE PATH EASMENT TO
BE ADJUSTEDTO
MATCH REALIGNED PATH
OPEN SPACE AND DRAINAGE EASMENT
TO BE
ADJUSTED TO
FIT
THE GENERATOR ENCLOSURE EXISTING TREE
TO BE PROTECTED, IN PLACE
EXISTING CHAINLINK
FENCE24'-0"(E) BIKE PATH(E) BIKE
PATHBIKE PATH TO BE REMOVED 37'-
9"16'-9"40'-6"
LANDSCAPE
6'H CHAINLINK FENCE
ENCLOSURE 10'-0" H. CMU
WALL DAY
TANK 2) 6'
H
CHAINLINK DBL. GATES INTO ENCLOSURE,
6'-0" GATE OPENING
EA.6' H
CHAINLINK GATE
INTO ENCLOSURE 3'-0" GATE OPENING 6"
HIGH CONTAINMENT
CURB SURROUNDING
FUEL TANK FUEL TANK ACCESS LADDER 32'-0"EXISTING
TREES TO
BE
REMOVED EXISTING
TREE TO BE PROTECTED,
INPLACE
3'-6"
8"8"
CMU WALL (10'-0" H.)33'-4"DAY TANK
GENERATOR, SET ON 6"
CONCRETE PAD, TYPICAL
Sheet Number
Sheet Title Copyright
by
Cuningham
Group Architecture, Inc. (
All Rights Reserved)Current
Revision
Revisions Project Information
Project
No.:PIC /
AIC:Date:Phase:
Agency
Approval
Drawing
Package
201
Main
St. SE, Suite
325, Minneapolis, MN
55414 Cuningham Group Architecture,
Inc.www.cuningham.com
Key Plan 7/25/2019
2:49:14 PMBIM 360://18-0327 - Dignity