HomeMy WebLinkAbout24-01097 Fire Report_RedactedNFIRS-1 Basic
40060 CA 02 19 2024 Fire Station
4 (FS4)
24-01097 0
FDID State Month Day Year Station Number Exposure
Location Type
Census tract:
Street Address
Intersection
In Front Of
Rear Of
Adjacent To
Directions
US National Grid
333 MADONNA
Number Prefix Street or Highway Street Type Suffix
San Luis Obispo CA 93401
Apt./Suite/Room City State Zip Code
Cross Street
Incident Type
445-Arcing, shorted electrical equipment
Aid Given Or Received
1 Mutual Aid Received
2 Auto. Aid Received
3 Mutual Aid Given
4 Auto. Aid Given
5 Other Aid Given
None
Their FDID Their
State
Their Incident Number
Dates and Times
Alarm 02 19 2024 14:07
Arrival 02 19 2024 14:12
Controlled
Last Unit
Cleared
02 19 2024 15:15
Shifts and Alarms
A FZ4
Shift or
Platoon
Alarms District
Special Studies
9244 4 - Unknown
ID#Value
A
B
C
D
E1 E2
E3
Page 1 of 7
Actions Taken
87-Investigate fire out on arrival
Primary Action Taken
Resources
Apparatus or Personnel Module is used.
Apparatus Personnel
Suppression 6 17
EMS 0 0
Other 0 0
Resource counts include aid received
resources.
Estimated Dollar Losses and Values
Losses:Required for all fires if
known. Optional for all
non-fires.
None
Property:$
Contents:$
Pre-Incident Values: Optional None
Property:$
Contents:$
Completed Modules
2 - Fire
3 - Structure Fire
4 - Civilian Fire Cas.
5 - Fire Service Cas.
6 - EMS
7 - HazMat
8 - Wildland Fire
9 - Apparatus
10 - Personnel
11 - Arson
Casualties None
Deaths Injuries
Fire
Service
0 0
Civilian 0 0
Detector
Required for Confined Fires
1 - Detector Alerted Occupants
2 - Detector Did Not Alert Them
3 - Unknown
Hazardous Materials Release
1 - Natural Gas
2 - Propane Gas
3 - Gasoline
4 - Kerosene
5 - Diesel Fuel / Fuel Oil
6 - Household Solvents
7 - Motor Oil
8 - Paint
0 - Other
None
Mixed Use Property
Not Mixed
10 - Assembly Use
20 - Education Use
33 - Medical Use
40 - Residential Use
51 - Row Of Stores
53 - Enclosed Mall
58 - Business and
Residential
59 - Office Use
60 - Industrial Use
63 - Military Use
65 - Farm Use
00 - Other Mixed Use
Property Use None
Structures
131 Church, Place of Worship
161 Restaurant or Cafeteria
162 Bar/Tavern or Nightclub
213 Elementary School, Kindegarten
215 High School, Junior High
241 College, Adult Education
311 Nursing Home
331 Hospital
341 Clinic, Clinic-Type Infirmary
342 Doctor/Dentist Office
361 Prison or Jail, Not Juvenile
419 1- or 2-Family Dwelling
429 MultiFamily Dwelling
439 Rooming/Boarding House
449 Commerical Hotel or Motel
459 Residential, Board and Care
464 Dormitory/Barracks
519 Food and Beverage Sales
539 Household Goods, Sales, Repairs
571 Gas or Service Station
579 Motor Vehicle/Boat Sales/Repairs
599 Business Office
615 Electric-Generating Plant
629 Laboratory/Science Laboratory
700 Manufacturing Plant
819 Livestock/Poultry Storage (Barn)
882 Non-Residential Parking Garage
891 Warehouse
Outside
124 Playground or Park
655 Crops or Orchard
669 Forest (Timberland)
807 Outdoor Storage Area
919 Dump or Sanitary Landfill
931 Open Land or Field
936 Vacant Lot
938 Graded/Cared for Plot of Land
946 Lake, River, Stream
951 Railroad Right-of-Way
960 Other Street
961 Highway/Divided Highway
962 Residential Street/Driveway
981 Construction Site
984 Industrial Plant Yard
Property Use:
Description
Look up and enter a Property Use code and
description only if you have NOT checked a
Property Use box.
Owner
Local Option Person/Entity Type Business Name (if applicable)Phone Number
Mr., Ms., Mrs.First Name MI Last Name Suffix
Number Prefix Street or Highway Street Type Suffix
Post Office Box Apt./Suite/Room City
State Zip Code
F G1 G2
H1
H2
H3 I
J
K2
Page 2 of 7
Remarks:
E4 arrived at scene for report of fire alarm activation. Four story hotel nothing showing investigating. E4 crew made entry side
Alpha, met with a front desk manager who stated there was a small fire in the electrical room area. E4 Captain was directed
to the electrical room Charlie/Delta corner division 1 via interior of hotel. Upon arrival to the electrical room I found no fire,
light residual smoke. Manager stated that two electricians were working in the room. I witnessed electrician tools lying on
the ground next to a large breaker box 12'x 22" box that appeared to be damaged from an arching flash. E4 shut off main
power to building, backup generators were activated. The 12' x 20' room and the adjoining rooms and exterior were searched
for the electricians. E4 made contact with City Fire for an update on conditions requested one additional apparatus and
Battalion Chief to respond, Battalion Chief upgraded to 1st alarm which he cancelled shortly after arriving at scene. Within
approximately 10 minutes an electrician arrived (co-worker) and confirmed the unexpected arching from the electrical box
and stated the electrician working on box was taken to SVH ER via private vehicle with burns to his hands. No patient contact
from SLOFD. E4 spoke with electrical contractor owner of business and advised him to contact/notify OSHA of
incident. E4 also spoke to Embassy Suites manager and advised him to inform his supervisor and to tie in with the
contractor ...
Full primary narrative can be found in NFIRS 1S - Supplemental
Authorization
14845 Barrett, Richard Fire Engineer 02/20/2024
Officer In Charge ID Signature Position or Rank Assignment Date
14845 Barrett, Richard Fire Engineer 02/20/2024
Member Making Report
ID
Signature Position or Rank Assignment Date
L
M
PaJe of
NFIRS-9 Apparatus or Resources
40060 CA 02 19 2024 Fire Station
4 (FS4)
24-01097 0
FDID State Month Day Year Station Number Exposure
B
Apparatus/Resource Dates/Times Sent
Number
of People Apparatus Use Actions Taken
ID:BC1
Type:92-Chief officer car
Dispatch:02/19/2024 14:19
Arrival:02/19/2024 14:25
Clear:02/19/2024 15:15
Sent 1 Suppression
EMS
Other
81-Incident command
ID:E3
Type:11-Engine
Dispatch:02/19/2024 14:23
Arrival:
Clear:02/19/2024 14:28
Sent 3 Suppression
EMS
Other
92-Standby
ID:E4
Type:11-Engine
Dispatch:02/19/2024 14:07
Arrival:02/19/2024 14:12
Clear:02/19/2024 15:15
Sent 3 Suppression
EMS
Other
87-Investigate fire out on
arrival
ID:MR1
Type:
70-Medical & rescue unit,
other
Dispatch:
Arrival:02/19/2024 14:30
Clear:02/19/2024 14:50
Sent 3 Suppression
EMS
Other
60-Systems and services,
other
ID:T1
Type:12-Truck or aerial
Dispatch:02/19/2024 14:19
Arrival:02/19/2024 14:26
Clear:02/19/2024 14:33
Sent 4 Suppression
EMS
Other
92-Standby
ID:T2
Type:12-Truck or aerial
Dispatch:02/19/2024 14:23
Arrival:
Clear:02/19/2024 14:28
Sent 3 Suppression
EMS
Other
92-Standby
A
Page 4 of 7
NFIRS-10 Personnel
40060 CA 02 19 2024 Fire Station
4 (FS4)
24-01097 0
FDID State Month Day Year Station Number Exposure
B
Apparatus/Resource Dates/Times Sent
Number
of People Apparatus Use Actions Taken
ID:BC1
Type:92-Chief officer car
Dispatch:02/19/2024 14:19
Arrival:02/19/2024 14:25
Clear:02/19/2024 15:15
Sent 1 Suppression
EMS
Other
81-Incident command
Personnel ID Name Rank Role Attend Actions Taken
41550 Hais, Ray Battalion
Chief
ID:E3
Type:11-Engine
Dispatch:02/19/2024 14:23
Arrival:
Clear:02/19/2024 14:28
Sent 3 Suppression
EMS
Other
92-Standby
Personnel ID Name Rank Role Attend Actions Taken
99163 Martin, Ted Firefighter
54183 King, John Engineer
92710 Witt, James Captain
ID:E4
Type:11-Engine
Dispatch:02/19/2024 14:07
Arrival:02/19/2024 14:12
Clear:02/19/2024 15:15
Sent 3 Suppression
EMS
Other
87-Investigate fire out on
arrival
Personnel ID Name Rank Role Attend Actions Taken
99188 Thoele, Brendan Firefighter
14845 Barrett, Richard Captain
99161 Hutslar, Dane Engineer
ID:MR1
Type:
70-Medical & rescue unit,
other
Dispatch:
Arrival:02/19/2024 14:30
Clear:02/19/2024 14:50
Sent 3 Suppression
EMS
Other
60-Systems and services,
other
Personnel ID Name Rank Role Attend Actions Taken
73250 Renner, David AR
34590 Flatos, Alec AR
57382 Larsen, Patrick AR
ID:T1
Type:12-Truck or aerial
Dispatch:02/19/2024 14:19
Arrival:02/19/2024 14:26
Clear:02/19/2024 14:33
Sent 4 Suppression
EMS
Other
92-Standby
Personnel ID Name Rank Role Attend Actions Taken
100076 McClanahan, Maren Firefighter
A
Page 5 of 7
70995 Pratt, Jason Captain
92892 Woods, Mitchell Engineer
99186 McAninch, Scott Engineer
ID:T2
Type:12-Truck or aerial
Dispatch:02/19/2024 14:23
Arrival:
Clear:02/19/2024 14:28
Sent 3 Suppression
EMS
Other
92-Standby
Personnel ID Name Rank Role Attend Actions Taken
61580 Mason, Ryan Captain
52001 Joy, Cullen Engineer
30791 Doolin, Luke Firefighter
Page 6 of 7
NFIRS-1S Supplemental
40060 CA 02 19 2024 Fire Station
4 (FS4)
24-01097 0
FDID State Month Day Year Station Number Exposure
Primary Narrative:
E4 arrived at scene for report of fire alarm activation. Four story hotel nothing showing investigating. E4 crew made entry side
Alpha, met with a front desk manager who stated there was a small fire in the electrical room area. E4 Captain was directed
to the electrical room Charlie/Delta corner division 1 via interior of hotel. Upon arrival to the electrical room I found no fire,
light residual smoke. Manager stated that two electricians were working in the room. I witnessed electrician tools lying on
the ground next to a large breaker box 12'x 22" box that appeared to be damaged from an arching flash. E4 shut off main
power to building, backup generators were activated. The 12' x 20' room and the adjoining rooms and exterior were searched
for the electricians. E4 made contact with City Fire for an update on conditions requested one additional apparatus and
Battalion Chief to respond, Battalion Chief upgraded to 1st alarm which he cancelled shortly after arriving at scene. Within
approximately 10 minutes an electrician arrived (co-worker) and confirmed the unexpected arching from the electrical box
and stated the electrician working on box was taken to SVH ER via private vehicle with burns to his hands. No patient contact
from SLOFD. E4 spoke with electrical contractor owner of business and advised him to contact/notify OSHA of
incident. E4 also spoke to Embassy Suites manager and advised him to inform his supervisor and to tie in with the
contractor in regard to OSHA notification. Scene was turned over to hotel manager and electrician.
OSHA was contacted via phone 02/20/2024 at 0845 hrs. @
SLO city building department was also contacted 02/20/2024 @ 0925 hrs. Michael Loew Building Official will return my call
ASAP.
A