HomeMy WebLinkAbout303310-002 2023-02-08 City of SLO Parking Structure 1A-CMP-MMEarth Systems Pacific DAILY FIELD REPORT
Date:
Map/Sketch:
NOTE: No guarantee or warranty of the contractor's work is made, expressed or implied.
Project No.:
OSHPD No.:
DSA File:
DSA App.:
303310-002
0
N/A
N/A
2/8/2023
JMCContractor:
Bill F.Met With:
Building Pad Parking/Roadway
Observation Embankment Trench Backfill
TYPE OF WORK
Project Name:
Project Location:
Project Manager:
Copies To:
SEC of Palm and Nipomo Streets
R. Down
ESP
City of San Luis Obispo - Cultural Arts Parking Structure 1A
Moisture
STD:13220Observation & Testing
Nuc. Gauge Make: CPN
Nuc. Gauge Model No. 5745
Test Only Retaining Wall Other
Density
STD:24102
EQUIPMENT ONSITE:
Summary: Onsite late am. I spoke with Bill F. and he asked that I test the joint trench and vaults at
different elevations. 95% compaction is required 6" above top of pipe per City of Slo Trench detail.
I observed the compaction of the 1st 1' lift over electrical pipe using a whacker then they placed
the 2 2" comm conduits then I tested the 1st lift over that and final lift to 10" BFS. All comp tests
taken today met passing requirements
Test Location Depth/
Elevation (ft)Moisture (%)Dry Density
(pcf)
Max Dry
Density (pcf)
Relative
Comp. (%)
Rel. Comp.
Spec
Failing Test *
Passing
Retest **
Field Rep: Mark Meeks
San Luis Obispo Santa Maria
(805) 544-3276 (805) 928-2991
(805) 544-1786 fax (805) 928-9253 fax
Hollister Fremont
(831) 637-2133 (510) 353-3883
(831) 637-0510 fax (888) 567-4293 fax
1 2
3 4 5678
Montery Street