Loading...
HomeMy WebLinkAboutItem 4b. 10 Higuera St. (ARCH-0358-2023) PLANNING COMMISSION AGENDA REPORT SUBJECT: REVIEW OF A NEW MIXED-USE PROJECT THAT CONTAINS APPROXIMATELY 23,164 SQUARE FEET OF COMMERCIAL SPACE AND A ONE BEDROOM RESIDENTIAL UNIT, WITH ASSOCIATED SITE IMPROVEMENTS, A SIGN PROGRAM, AND A REQUEST TO REMOVE TW O TREES AND REPLANT 25 TREES PROJECT ADDRESS: 10 Higuera Street FILE NUMBER: ARCH-0358-2023 BY: Rachel Cohen, Senior Planner Phone Number: (805) 781-7574 Email: rcohen@slocity.org RECOMMENDATION Adopt the Draft Resolution (Attachment A) approving the proposed new mixed-use project, associated site design and improvements, sign program, and the removal of two trees based on findings and subject to conditions of approval. This project is categorically exempt from environmental review under CEQA Guidelines section 15332 (Class 32, Infill Development Projects). SITE DATA Applicant Keith Sweeny Zone Service Commercial with a special consideration overlay (C-S-S) & Tourist Commercial with a mixed-use overlay (C-T- MU) zone General Plan Land Use General Retail and Services & Manufacturing Site Area 2.96-acre parcel (128,938 square feet) Environmental Determination Categorically exempt from environmental review under CEQA Guidelines section 15332 (Class 32, Infill Development Projects) 1.0 SUMMARY Keith Sweeny (Applicant) has applied for a Major Development Review (ARCH -0358- 2023) to allow for the construction of a new mixed-use project that contains approximately 23,164 square feet of commercial space [proposed to be occupied by a distillery, restaurant, tasting room, and associated spaces] and a one -bedroom residential unit with associated site improvements, a sign program, and a request to remove two trees on a 2.96 acre parcel zoned Service Commercial with a special consideration overlay (C-S-S) and Tourist Commercial with a mixed-use overlay (C-T-MU). Meeting Date: 6/26/2024 Item Number: 4b Time Estimate: 45 minutes Figure 1: Subject Property Location Page 59 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 2.0 COMMISSION'S PURVIEW The Planning Commission’s role is to review the project for consistency with the General Plan, Zoning Regulations, Community Design Guidelines (CDG), Sign Regulations and applicable City Standards. Per Zoning Regulations section 17.106.030(D)(3) a nonresidential / mixed-use development with more than ten thousand gross square feet of new construction requires discretionary Planning Commission review. 3.0 PROJECT INFORMATION 3.1 Project Description The applicant has applied for a new mixed-use project that contains approximately 23,164 square feet of commercial space [proposed future uses to be a distillery, restaurant, tasting room, and associated spaces] and a one-bedroom residential unit with associated site improvements, a sign program, and a request to remove two trees. The project is proposed on property located at 10 Higuera Street (Assessor Parcel Numbers [APN] 004- 511-015 and 004-511-022) that is 2.96-acre parcel acres in size located in the Service Commercial with a special consideration overlay (C-S-S) and Tourist Commercial with a mixed-use overlay (C-T-MU) zones. The project would include on-site amenities including a trash enclosure, a parking lot, bicycle parking, and landscaping (including the planting of 25 trees) (see Attachment B, Project Plans). 3.2 Site Information Present Development and Uses Partially developed site with a small distillery, some site improvements including access, some parking, and landscaping. Topography Relatively flat. San Luis Creek is located along the west property line and Exposition Creek is located along the south property line. Access Higuera Street Surrounding Zoning Designations and Uses East: Higuera Street, (C-S-MU) Retail Businesses West: San Luis Creek and Highway 101 North: (C-T-MU) Caltrans District 5 Offices South: (C-S-MU) Cemetery 3.3 Project Design Architecture: Contemporary Design details: The building utilizes symmetrical and asymmetrical lines, large windows, and a mix of materials and colors to provide contemporary design. Materials: Vertical box rib metal siding, vertical wood siding, concrete bulkheads, dark bronze aluminum storefront windows, and a standing seam metal room. Colors: Black, Gray, natural wood, and dark bronze colors are proposed. Page 60 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 Figure 3: Rendering of the proposed project looking west toward the public entrance to the building. Figure 3: Rendering of the proposed project as viewed from the loading area towards the front entrance. Page 61 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 3.4 Sign Program Municipal Code Chapter 15.40 outlines the City’s Sign Regulations. Subsection 15.40.485 describes that sign programs are required for new mixed-use projects in order to establish ongoing sign requirements and to ensure the signage is complementary and compatible with the development and the surrounding neighborhood and commercial district. The applicant has proposed a sign program and staff has highlighted components of the sign program in Table 1. Details of the sign program and example signage are provided on Sheet A3.1 of the Project Plans (Attachment B). Table 1. Proposed Sign Program Design Guidelines Proposed Signs Maximum Size Max Number Design Material Illumination Sign Zone 1 (wall sign) 150 square feet 1 Three-dimensional lettering and / or logo balanced and in proportion with the building. High Quality Materials and colors that complement and / or similar to the building materials. Exterior or internal illumination permitted (consistent with SLOMC 15.40.430) Sign Zone 2 (hanging, suspended, or awning if applicable) Hanging or Suspended signs: max area of 8 square feet (consistent with SLOMC 15.40.470(E)(2)). 1 All signage shall be three-dimensional lettering and or logo balanced in proportion with the building. High Quality Materials and colors that complement and / or similar to the building materials. Exterior or internal illumination permitted (consistent with SLOMC 15.40.430) Sign Zone 3 (window signs) Signs shall be limited to a maximum of 24 square feet or 15 percent of the window area, whichever is less (SLOMC 15.40.470(B)(2)) 1 per window Signs shall be limited to small graphics and text that serve to frame a window or provide information. Signs are two-dimensional adhered to glass of windows. High Quality Materials and colors that complement and / or similar to the building materials. Sign Zone 4 (wall sign) 150 square feet 1 Three-dimensional lettering and / or logo balanced and in proportion with the building. High Quality Materials and colors that complement and / or similar to the building materials. Exterior or internal illumination permitted (consistent with SLOMC 15.40.430) Sign Zone 5 (wall sign that faces the rear of the property) 300 square feet 1 Three-dimensional lettering and / or logo balanced and in proportion with the building. High Quality Materials and colors that complement and / or similar to the building materials. Exterior or internal illumination permitted (consistent with SLOMC 15.40.430) Page 62 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 3.5 Tree Removal Request The applicant is requesting to remove two Schinus molle (Peruvian pepper) trees and replant 25 trees that include 12 strawberry trees, eight buckeye trees and five red oak trees. 3.6 Project Statistics Staff has reviewed the project for consistency with relevant development standards of the Zoning Regulations and have summarized its compliance in Table 2 below. The project is not seeking any exceptions from development standards. Table 2. Project Compliance with the Zoning Regulations Development Standards Site Details Proposed Allowed/Required* C-S-S Zone C-T-MU Zone Minimum Setbacks Front Interior Side Rear > 15 feet None 20 feet (Creek setback) 15 feet None 20 feet (Creek setback) 10 feet None None Maximum Building Height 33 feet 5 inches to 40 feet 35 feet 45 Feet Maximum Lot Coverage 13% 75% 75% Floor Area Ratio (FAR) 0.14 to 0.29 1.5 2.5 Affordable Housing Pay in-lieu fee and commercial linkage fee Provide units or pay in-lieu fee and commercial linkage fee Parking and Loading Standards Parking Spaces (Total) Commercial Space Residential EV Ready EV Capable 78 74 1 8 20 75 74 1 8 20 Bicycle Spaces (Total) Short-term Long-term 35 20 15 35 20 15 Motorcycle Parking 4 4 Tree Removal Replacement Plantings 2 trees removed; 25 trees to be replanted on- site 1:1 replacement planting ratio *2022 Zoning Regulations Page 63 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 4.0 PREVIOUS REVIEW Both the Architectural Review Commission (ARC) and the Tree Committee have reviewed the proposed project. Details regarding their purview and review can be found in the associated staff reports linked below. May 6, 2024: The (ARC) reviewed the proposed mixed-use project and found the proposed project design consistent with the Community Design Guidelines, Sign Regulations, and applicable City Standards with specific direction regarding design changes and recommended the Planning Commission approve the design . May 20, 2024: The Tree Committee (TC) reviewed the removal of two Peruvian pepper (Schinus molle) trees and the replanting of 25 new trees as a part of the proposed new mixed-use project. The Tree Committee recommended the Planning Commission approve the Tree Removal Application with specific direction regarding trees species selection. 4.0 PROJECT ANALYSIS 4.1 Consistency with the General Plan The General Plan does not provide specific design guidelines for new structures located within General Retail and Services & Manufacturing land use areas other than to discuss that new commercial buildings shall be accessed from arterial and collector streets and be designed and located to avoid increasing traffic on residential streets (Land Use Element Policy 3.1.2). As proposed, the projec t is accessed from Higuera Street, an arterial street (see Circulation Element Figure 1) and will not increase traffic on residential streets since the site is not located near residential areas. The new mixed-use project would also support the City’s land use designation’s purpose and application for General Retail and Services and Manufacturing land uses (Land Use Element Table 1). The project would include restaurant and retail uses, as well as l ight manufacturing and residential uses located near the intersection of Madonna Road and Highway 101. 4.2 Consistency with the Zoning Regulations As noted in Section 3.4 above, the proposed mixed-use project complies with the development standards for new structures located within the Service Commercial and Tourist Commercial zones. 4.3 Consistency with Design Guidelines The proposed project is a mixed-use project and with the proposed uses, zoning, and location it supports a more industrial / commercial design rather than residential. As such, staff evaluated the project for consistency with relevant standards and guidelines of the Community Design Guidelines (CDG), including Chapter 3, Section 3.3 (Industrial Project Design Guidelines) and Chapter 6 (Site Planning and Other Design Details) as well as the City’s Active Transportation Plan (ATC), Appendix C for bicycle parking design standards and Sign Regulations. Page 64 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 As proposed, the project would utilize a contemporary design that includes symmetrical and asymmetrical elements, large windows, and a mix of materials and colors. The exterior materials include vertical box rib metal siding, vertical wood siding, concrete bulkheads, dark bronze aluminum storefront windows, and a standing seam metal room. Blacks, Grays, natural wood, and dark bronze colors are proposed. The overall site plan has robust landscaping, and designated areas for vehicle and bicycle parking. On May 6, 2024, the ARC reviewed the proposed project and found it to be consistent with the CDG, ATC, and the sign regulations with two directional items and recommended the Planning Commission approve the project design. Provided below is a discussion on the two directional items: 1. Provide a change in color, materials, and/or window fenestration to the north elevation to provide architectural interest. Per direction from the ARC, the applicant has revised the north elevation to include more architectural interest by adding window fenestration and wrapping the wood accent feature from the west elevation around to the north elevation. Attachment B, Project Plans, includes the revised north elevation as part of the plans. The Planning Commission should discuss if the proposed revisions provide sufficient articulation and architectural features to break up the large wall expanse on the north elevation. 2. Provide screening around the bicycle lockers and/or paint them so that they better integrate into the site plan and overall architectural design. The applicant has indicated that they are willing to better integrate the long -term bicycle lockers into the site plan and design. As such, staff is recommending condition of approval #11 that states “Building plans submitted for the project shall show that the bicycle lockers are screened and/or painted so that they become integrated into the site and overall architectural design to the satisfaction of the Community Development Director.” Figure 5: Revised north elevation with additional window fenestration and wood detailing. Figure 5: Original north elevation design. Page 65 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 4.4 Consistency with Tree Regulations The City’s Tree Ordinance (Municipal Code Chapter 12.24) was adopted in 2010 and recently updated in 2019 with the purpose of establishing a comprehensive program for installing, maintaining, and preserving trees within the City. This ordinance establishes policies, regulations, and specifications necessary to govern installation, maintenance, removal, and preservation of trees to beautify the city; to purify the air; to provide shade and wind protection; to add environmental and economic value; and to preserve trees with historic or unusual value. On May 20, 2024, the Tree Committee reviewed the proposed project and found it to be consistent with tree regulations with one directional item and recommended the Planning Commission approve the tree removal request. Provided below is a discussion on the directional item. 1. The applicant should consider replacing the proposed twelve (12) Marina Strawberry trees (Arbutus) with an alternate species from the City's Master Tree List, with the goal of maximizing canopy potential. The Committee noted that Strawberry trees are not well suited for high traffic areas, as their leaf and fruit litter are messy and require constant cleanup / maintenance and, even at maturity, this species will not provide sufficient canopy coverage. Staff is recommending condition of approval #14(a) that states that “Arbutus x ‘marina’ shall not be planted as part of the landscape plan. The project shall select another species from the City’s Master Tree List to be planted instead, to the satisfaction of the City Arborist.” 5.0 ENVIRONMENTAL REVIEW The project is categorically exempt from provisions of CEQA described in Section 15332 (Infill) of the CEQA Guidelines because it consists of infill development consistent with the applicable General Plan designation and all applicable General Plan policies as well as with the applicable zoning designation and regulations, it is located within city limits on a project site of no more than 5 acres in size (only 2.96 acres) surrounded by urban uses (existing light manufacturing, distribution, storage, and office uses), the site has no value as habitat for endangered, rare, or threatened species, approval of the project would not result in any significant effects relating to traffic, noise, air quality, or water quality, and the site can be adequately served by all required utilities and public services. 6.0 OTHER DEPARTMENT COMMENTS The project has been reviewed by the Engineering Division, Transportation Division, Building Division, Utilities Department, and Fire Department. Any conditions of approval or informational notes from these departments and divisions have been incorporated into the Draft Resolution (Attachment A) for project approval. Page 66 of 98 Item 4b ARCH-0358-2023 Planning Commission Report – June 26, 2024 7.0 ALTERNATIVES 1. Continue project. An action to continue the item should include a detailed list of additional information or analysis required to make a decision. 2. Deny the project. An action denying the project should include findings that cite the basis for denial and should reference inconsistency with the General Plan, Zoning Regulations, or other policy documents. 8.0 ATTACHMENTS A - Draft Resolution for 10 Higuera (ARCH-0358-2023) approving a new, mixed-use project that contains approximately 23,164 square feet of commercial space and a one-bedroom residential unit with associated site improvements, a sign program, and a request to remove two trees. B - Project Plans for 10 Higuera (ARCH-0358-2023) Page 67 of 98 Page 68 of 98 RESOLUTION NO. PC-XXXX-24 A RESOLUTION OF THE CITY OF SAN LUIS OBISPO PLANNING COMMISSION APPROVING A NEW MIXED-USE PROJECT THAT CONTAINS APPROXIMATELY 23,164 SQUARE FEET OF COMMERCIAL SPACE AND A ONE BEDROOM RESIDENTIAL UNIT, WITH ASSOCIATED SITE IMPROVEMENTS, A SIGN PROGRAM, AND A REQUEST TO REMOVE TWO TREES AND REPLANT 25 TREES. THE PROJECT IS EXEMPT FROM ENVIRONMENTAL REVIEW UNDER SECTION 15332 (CLASS 32, INFILL DEVELOPMENT) OF THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) GUIDELINES AS REPRESENTED IN THE STAFF REPORT AND ATTACHMENTS DATED JUNE 26, 2024 (10 HIGUERA STREET, ARCH-0358-2023) WHEREAS, the Architectural Review Commission of the City of San Luis Obispo conducted a public hearing in the Council Chamber of City Hall, 990 Palm Street, on May 6, 2024, reviewed the new mixed-use project at 10 Higuera Street and recommended the Planning Commission find the project consistent with the Community Design Guidelines, Sign Regulations, and applicable City Standards with two design modifications, pursuant to a proceeding instituted under ARCH-0358-2023, Keith Sweeny, applicant; and WHEREAS, the Tree Committee of the City of San Luis Obispo conducted a public hearing in the Council Hearing Room of City Hall, 990 Palm Street, San Luis Obispo, California, on May 20, 2024, and recommended that the Planning Commission find the project consistent with the Tree Regulations with one modification, pursuant to a proceeding instituted under ARCH-0358-2023, Keith Sweeny, applicant; and WHEREAS, the Planning Commission of the City of San Luis Obispo conducted a public hearing in the Council Chamber of City Hall, 990 Palm Street, on June 26, 2024, to review a Major Development Project for new mixed-use project at 10 Higuera Street, pursuant to a proceeding instituted under ARCH-0358-2023, Keith Sweeny, applicant; and WHEREAS, the Planning Commission of the City of San Luis Obispo has duly considered all evidence, including recommendations by staff, presented at said hearing; and WHEREAS, notices of said public hearings were made at the time and in the manner required by law; and NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of San Luis Obispo as follows: SECTION 1. Findings. The Planning Commission hereby grants final approval for the project (ARCH-0358-2023), based on the following findings: Development Review Page 69 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 2 1. The project is consistent with the Land Use Element of the General Plan, particularly Land Use Element Table 1 and Policy 3.1.2 because it supports the City’s land use designation’s purpose and application for General Retail and Services and Manufacturing land uses by providing restaurant and retail uses, as well as light manufacturing and residential uses located near the intersection of Madonna Road and Highway 101 and the new mixed-use building will be accessed from Higuera Street, an arterial street and will not increase traffic on residential streets since the site is not located near residential areas . 2. As conditioned, the project conforms to applicable property development standards, set forth in the Zoning Regulations, for the Service Commercial with a special consideration overlay (C-S-S) zone and Tourist Commercial with a mixed- use overlay (C-T-MU) zone. The project is an allowed use in the C-S-S and C-T- MU zones and would be compatible with established commercial uses on Higuera Street. 3. On May 6, 2024, the ARC reviewed the project and recommended the Planning Commission find it consistent with the CDG, ATC, and Sign Regulations subject to considerations of (1) providing a change in color, materials, and/or window fenestration to the north elevation to provide architectural interest and (2) providing screening around the bicycle lockers and/or painting them so that they better integrate into the site plan and overall architectural design. As conditioned, the project building, site, and sign designs would be complementary improvements to the existing neighborhood and incorporate a contemporary design that exhibit proper proportion, articulation, rhythm, and balance. 4. As conditioned, the project will not be detrimental to the health, safety, and welfare of persons living or working at the site or in the vicinity because conditions have been included that place limits on the number of persons allowed on site, restrict activities, provide adequate parking, and limit potential disturbances to neighboring properties. The project will be compatible with the existing site constraints and the character of the neighborhood. Sign Program 5. The sign program is consistent with the intent and purpose of Chapter 15.40 (Sign Regulations) and includes signs that comply with Section 15.40.480 (Design Principles) to provide sufficient visibility and identification without resulting in clutter or utilizing excessively sized signage. In addition, the ARC reviewed the sign program and found it to be consistent with the intent of the Sign Regulations and CDG. Page 70 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 3 Tree Removal 6. The proposed tree removal request is consistent with Municipal Code Section 12.24.090(G) because the two trees are located interior to the almost 3 -acre project site and are non-native and therefore have a lower preservation priority. In addition, the Tree Committee reviewed the tree removal application and found the request to be consistent with the Tree Regulations. 7. As conditioned, the proposed tree removal request is consistent with Municipal Code Section 12.24.090(J) because the two tree removals will be compensated by planting 25 new trees on the same property. SECTION 2. Environmental Review. The project is categorically exempt from provisions of CEQA described in Section 15332 (Infill) of the CEQA Guidelines because it consists of infill development consistent with the applicable General Plan designation and all applicable General Plan policies as well as with the applicable zoning designation and regulations, it is located within city limits on a project site of no more than 5 acres in size (only 2.96 acres) surrounded by urban uses (existing light manufacturing, distribution, storage, and office uses), the site has no value as habitat for endangered, rare, or threatened species, approval of the project would not result in any significant effects relating to traffic, noise, air quality, or water quality, and the site can be adequately served by all required utilities and public services. SECTION 3. Action. The Planning Commission hereby grants final approval to the project with incorporation of the following conditions: Planning Division – Community Development Department 1. Final project design and construction drawings submitted for a building permit shall be in substantial compliance with the project description and plans represented in the Staff Report dated June 26, 2024. A separate, full-sized sheet shall be included in the working drawings submitted for a building permit that lists all conditions of approval and applicable code requirements as Sheet No. 2. Reference shall be made in the margin of listed items as to where these requirements are addressed in the plans. Any change to the approved design, colors, materials, landscaping, or other conditions of approval must be approved by the Community Development Director and may be subject to review by the Architectural Review Commission, as deemed appropriate. 2. Plans submitted for a building permit shall call out the colors and materials of all proposed building surfaces and other improvements. Colors and materials shall be consistent with the colors and materials board submitted with the Development Review application. Page 71 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 4 3. Plans shall indicate the type of materials for the window frames and mullions, their dimensions, and colors. Plans shall include the materials and dimensions of all lintels, sills, surrounds recesses and other related window features. 4. Plans submitted for a building permit shall include the locations of all lighting such as bollard style landscaping or path lighting. All wall-mounted lighting fixtures shall be clearly labeled on building elevations and complement the building architecture. The lighting schedule for the building shall include a graphic representation of the proposed lighting fixtures and cut sheets in the submitted plans. The selected fixture(s) shall be shielded to ensure that light is directed downward consistent with standards outlined in Section 17.70.100 (Lighting and Night Sky Preservation). 5. Mechanical and electrical equipment shall be located internally to the building to the greatest extent possible. Plans submitted for a building permit shall include sectional views of the building, which clearly show the sizes of any proposed condensers and other mechanical equipment. If any condenser, or other mechanical equipment, is to be placed on the roof, plans submitted for a building permit shall confirm that parapets and other roof features will adequately screen them. A line-of-sight diagram may be required to confirm the proposed screening will be adequate. Please note this requirement applies to the initial construction of the building and any subsequent improvements. 6. Plans submitted for a building permit shall include landscape and irrigation plans. The legend for the landscaping plan shall include the sizes and species of all groundcovers, shrubs, and trees with corresponding symbols for each plant material showing their specific locations on plans. Details on the proposed surfaces and finishes of hardscapes shall also be included in the landscaping plan. 7. Plans submitted for a building permit shall include elevations and detail drawings of all proposed fences and/or walls. Any proposed fences, walls, and hedges shall comply with standards outlined in Section 17.70.070 (Fences, Walls, and Hedges). 8. The location of any required backflow preventer and double-check assembly shall be shown on all site plans submitted for a building permit, including the landscaping plan. Construction plans shall also include a scaled diagram of the equipment proposed. Where possible, as determined by the Utilities Director, equipment shall be located inside the building within 20 feet of the front property line. Where this is not possible, as determined by the Utilities Director, the back - flow preventer and double-check assembly shall be located in the street yard and screened using a combination of paint color, landscaping and, if deemed appropriate by the Community Development Director, a low wall. The size and configuration of such equipment shall be subject to review and approval by the Utilities and Community Development Directors. Page 72 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 5 9. Plans submitted for a sign permit shall be in substantial conformance with the approved Sign Program. Modifications to the Sign Program or a request for additional signage may require review by the Architectural Review Commission or Community Development Director, as deemed appropriate. 10. Plans submitted for a building permit shall clearly depict the location of all required short and long-term bicycle parking for all intended uses. Plans shall show all areas designated for long-term bicycle parking such as bicycle lockers, interior spaces, or storage rooms. Short-term bicycle racks shall be consistent with the City Active Transportation Plan Design Guidelines and feature “hi-low style” campus racks (such as “Peak Racks”) or an inverted “U” rack design and shall be installed in close proximity to, and visible from, the main entries into the building. Sufficient detail shall be provided about the placement and design of bike racks, lockers, and interior spaces to demonstrate compliance with relevant Engineering Standards and Community Design Guidelines, to the satisf action of the Public Works and Community Development Directors. 11. Building plans submitted for the project shall show that the bicycle lockers are screened and/or painted so that they become integrated into the site and overall architectural design to the satisfaction of the Community Development Director.” Housing – Community Development Department 12. The applicant shall pay an inclusionary housing in-lieu fee and commercial linkage fee consistent with Municipal Code Chapters 17.138 and 4.60 prior to building permit approval. City Arborist – Community Development Department 13. The tree removals for the site shall include the two (2) Schinus molle (Peruvian Pepper) tree removals requested by the applicant in the project proposal. 14. The project shall replant, at a minimum, twenty-five (25) trees. All trees replanted shall be 15-gallon or 24-inch box trees. Trees shall be planted according to the landscaping plan with the following exception: a. Arbutus x ‘marina’ shall not be planted as part of the landscape plan. The project shall select another species from the City’s Master Tree List to be planted instead, to the satisfaction of the City Arborist. 15. All trees shall be planted per the City’s Engineering Standards for tree planting prior to final building inspection. All trees planted as part of a compensatory plan shall survive and any trees that do not survive shall be replanted. Page 73 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 6 16. The building plan submittal shall show all existing trees to be removed and trees to be retained. The plan shall show any neighboring trees with canopies/root zones within the area of construction disturbance. Tree preservation measures shall be shown and noted on the building plans to the satisfaction of the City Arborist. 17. California Fish and Game Code Section 3503.5 and the Migratory Bird Treaty Act of 1972 prevents the removal of trees with active nests. To account for most nesting birds, removal of trees should be scheduled to occur in the fall and winter (between September 1st and January 31st) and after the young have fledged. If removing trees during the nesting season (February 1st to August 31st), a qualified biologist shall inspect any trees marked for removal that contain nests to determine if the nests are active. If there are active nests, trees shall not be removed and may only be removed once a qualified biologist provides a confirmation memo that breeding / nesting is completed, and young have fledged the nest prior to removal of the tree to the satisfaction of the Community Development Director or City Biologist. Engineering Division – Community Development / Public Works Departments 18. Improvement plan submittal shall show the existing Biological Open Space Creek Easement limits, and the 20-foot-wide creek setback and future bike path easement. 19. The project shall show and document compliance with the Post Construction Stormwater Regulations as promulgated by the Regional Water Quality Control Board. The building permit application shall include the required PCR checklist to show compliance with any pertinent standards. Page 74 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 7 20. A Private Stormwater Conveyance System Management and Maintenance Agreement (Operations and Maintenance Agreement) shall be provided, City will provide template. The agreement shall be recorded and shall reference a separate maintenance program for the stormwater items and the approved building plans. 21. Parking lots with parking spaces and drive aisles, including bay widths and turnaround areas will be subject to the latest City Engineering Standards. 22. Plan shall denote the finish floor elevations, elevations of finish grades adjacent to building, established parking lot grades, drainage patterns and locations and gradients of cut or fill slopes. 23. Drainage report shall provide a summary of the pre vs. post drainage analysis for the 2 through 100-year storm. Improved or diverted drainage shall not be directed across the side or rear property lines unless conveyed in an existing waterway, or a drainage easement. 24. New roof downspouts outlets shall show non-erosive discharge (such as splash blocks) to landscaped areas or approved outlet, or to required stormwater storage chambers per engineered plans. 25. As an option, the improved drainage may be retained/detained on site with a controlled outlet to mimic the pre-construction historic run-off (no increase of run- off volume, recreate sheet flow, and/or direct runoff to an existing concentrated outlet location). 26. The water service piping and water meter shall be sized in accordance with the approved fire sprinkler plans. 27. Provide walking surfaces that are part of an accessible route of travel between public way and accessible entrance. 28. Cleanouts for new sewer lateral on site shall be located at 100 feet minimum intervals. 29. Water meter and water service lateral to city main water line must be sized in accordance with approved fire sprinkler plans. If upsized meter required, the water service lateral, shall also be upsized. 30. The location of any required backflow prevention devices shall be shown on all site plans, including the landscaping plan. 31. Work adjacent to or within a channel or creek may require the approvals of Fish and Game, Army Corp of Engineers, and/or the Regional Water Quality Control Board. Provide copies of any required permits or a written waiver or exemption for the same. Page 75 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 8 32. Provide documentation that the adjoining property owner has been notified of the impending excavation and other future construction activity. 33. A CAL-OSHA permit is required for excavations or trenching greater than 5 feet in depth. A copy of the annual, provisional, or temporary permit shall be provided to the Building Division prior to building, utility, and/or grading permit issuance if applicable. CA Health and Safety Code Section 17922.5 34. All parking spaces shall be able to be entered in one movement. All spaces, drive aisles, etc. shall be designed so that all vehicles can exit to the adjoining street in a forward motion in not more than two maneuvers. For purposes of maneuverability, all required and proposed covered and uncovered spaces shall be assumed to be occupied by a standard size vehicle. 35. Include complete parking statistics on the cover sheet of the plans in accordance with the zoning regulations. Include the number of required and proposed vehicle spaces, motorcycle spaces, and bicycle parking spaces. The project summary shall include all required and proposed short-term and long-term bicycle parking spaces. Commercial centers shall include the number and location of the required 12’ x 25’ commercial loading zones. 36. Clearly show the location and extent of the A and B flood zones on the site plan. 37. Unless on-site fire hydrants are required or proposed the fire service backflow preventer shall be a double-check assembly. An interior double-check may be approved when the fire riser assembly is located not more than 25’ from the property line. 38. Double check assemblies shall comply with city Engineering Standard #6420. 39. Show the location of any existing private water well and private waste disposal system for reference if applicable. Show or note the disposition of any well, septic tank, or leach field. Abandonment of a water well or private waste disposal system shall be in accordance with local ordinance, plumbing code requirements, and state requirements. 40. Provide a Water Pollution Control Plan (W PCP) in the format provided by the Building Division for minor projects less than 1 acre of disturbance. 41. Erosion control measures are required in accordance with the grading ordinance and Waterway Management Plan Drainage Design Manual. Provide an erosion control plan and/or erosion control notes on the plans to the satisfaction of the Building Official and Public Works Director. Erosion control measures shall be implemented and maintained during all construction and ground disturbing activities. A detailed erosion control plan is required in accordance with Waterway Management Plan Section 3.7 and Section 10.0. Page 76 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 9 42. Notes shall be added to the plans whether floodproofing or partial floodproofing will be completed with this permit or not. 43. Regardless of the valuation of building improvements, all new building service equipment shall be elevated to 1’ above the BFE or otherwise protected in accordance with the CBC as amended locally for buildings located in the flood zone. 44. This project shall comply with the Floodplain Management Regulations. Analysis shall be provided to show that this development project is reasonably safe from flooding and that that the project will not adversely affect adjoining properties. 45. All utilities, including but not limited to gas, electrical panels, telephone panels, sewer laterals, water service, fire service, and utility conduits entering the structure must be sealed to preclude infiltration of floodwater. 46. Only one sewer connection is allowed per property. If connecting to the existing sewer lateral, provide the required video inspection. Include the invert elevations for the new sewer lateral. Transportation Division - Public Works Department 47. Applicable Citywide Transportation Impact Fees must be paid prior to building permit issuance. 48. Unless otherwise approved by the Public Works Director, removal/relocation of any trees, landscaping, fencing, irrigation, or other elements that are constructed by the Project within the existing 20-foot Bike Path Easement (recorded July 2 1, 2020) shall be completed by the property owner at no expense to the City within 90 days of the City providing notice to the property owner of intent to begin construction of Bike Path. Utilities Department 49. The construction plans for sewer and water services shall be in accordance with the engineering design standards in effect at the time the building permit is approved. Building permit submittal shall identify the size of existing and proposed water services, water meters, sewer lateral, and sewer services for the project, and shall include a licensed engineer’s design narrative and supportive engineering calculations. The project’s commercial and residential uses shall be metered separately. The project shall provide a separate city-owned water meter and service line, due to the landscaped area exceeding 1,000 square feet. 50. Plans submitted for a building permit shall show a private water sub -meter for the proposed new building, to the satisfaction of the Utilities Director. Page 77 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 10 51. Commercial uses in the project include food preparation; therefore, provisions for grease interceptors and FOG (fats, oils, and grease) storage within solid waste enclosure(s) shall be provided with the plans submitted for a building permit. These commercial facilities shall also provide an area to wash floor mats, equipment, and trash cans. The wash area shall be inside, drained to the sanitary sewer, and an Industrial Wastewater Discharge Survey and Permit Application shall be submitted, and permit obtained prior to issuance of occupancy permit. 52. The building permit submittal shall include a final landscape design plan and irrigation plan that includes all the criteria required in the City Engineering Standards Uniform Design Criteria for Landscaping and Irrigation. The building permit submittal shall include a completed Maximum Applied Water Allowance (MAWA) form based on the final landscape design plan and a hydrozone table with a summary of Estimated Total Water Use (ETWU) and the corresponding irrigation window. 53. The proposed project shall comply with the City’s Development Standards for Solid Waste Services. Show the location and size of the bin enclosure(s) that can store the required containers for waste, recycling, and organics. Building permit submittal shall include a letter of service from San Luis Garbage Company pasted on the plans. Code Requirements Building Division – Community Development Department 54. Please be aware of H-2 requirements for the “Still Tower” regarding fire protection requirements If over the maximum amount allowed by table (307.1 CBC). Please be especially aware of section 415.6 CBC/CFC due to 25% of the H occupancy will have to be located on the exterior wall. Please be aware of maximum quantities of anticipated amounts for the H-2 / H-3 occupancy as building setback would have to be changed as only 10’ is shown. (415.6.3 CBC) 55. Parapets may be required, but this will be determined during building review. (705.11 CBC) Utilities Department 56. Plans submitted for a building permit shall show a backflow preventor, consistent with City Engineering Standards Uniform Design Criteria 6.1.3 Cross Connections (required for restaurants and private fire-protection lines, including fire sprinkler systems), to the satisfaction of the Utilities Director and Fire Department. 57. Plans submitted for a building permit shall show clearance between the private water service line and private sewer lateral in compliance with the Plumbing Code, to be demonstrated upon building permit issuance. Page 78 of 98 Resolution No. PC-XXXX-24 ARCH-0358-2023 10 Higuera Street Page 11 58. The proposed sewer lateral serving the property shall be made with HDPE material and shall be installed per the City’s engineering design standards. Existing lateral(s) that are not proposed to be reused shall be abandoned at the City main consistent with City standards. 59. Potable city water shall not be used for major construction activities, such as grading and dust control. Recycled water is available through the City’s Construction Water Permit program. Indemnification 60. The applicant shall defend, indemnify, and hold harmless the City and/or its agents, officers and employees from any claim, action or proceeding against the City and/or its agents, officers, or employees to attack, set aside, void or annul, the approval by the City of this project, and all actions relating thereto, including but not limited to environmental review (“Indemnified Claims”). The City shall promptly notify the applicant of any Indemnified Claim upon being presented with the Indemnified Claim and the City shall fully cooperate in the defense against an Indemnified Claim. On motion by __________, seconded by __________, and on the following roll call vote: AYES: NOES: RECUSED: ABSENT: The foregoing resolution was passed and adopted this 26th day of June 2024. ___________________ Rachel Cohen, Secretary Planning Commission Page 79 of 98 Page 80 of 98 THIS PROJECT SHALL COMPLY WITH CURRENT APPLICABLE CODES & ORDINANCES 2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA HISTORICAL BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA EXISTING BUILDING STANDARDS CODE 2022 CALIFORNIA REFERENCE STANDARDS CODE CITY OF SAN LUIS OBISPO MUNICIPAL CODE: TITLE 15 BUILDINGS AND CONSTRUCTION CITY OF SAN LUIS OBISPO TITLE 17 ZONING REGULATIONS CALIFORNIA CODE REFERENCES DRAWING SYMBOLS Name Elevation HEIGHT/ ELEVATION MARKER NORTH ARROW Room name 101 150 SF ROOM NAME ROOM NUMBER ROOM AREA ROOF / GROUND SLOPE: INDICATES SLOPE AND DIRECTION OF SLOPE OVERHEAD LINES KEYNOTE DIVISION NUMBER AND SPECIFICATION ?XX.XXX DIMENSION LINES CENTERLINE OF COLUMN OR STUD CENTERLINE OF OPENING FACE OF STUD CITY OF SAN LUIS OBISPO - COMMUNITY DEVELOPMENT DEPARTMENT 919 PALM STREET SAN LUIS OBISPO, CA 93401 PH: 805.781.7180 CITY OF SAN LUIS OBISPO - BUILDING DEPARTMENT 919 PALM STREET SAN LUIS OBISPO, CA 93401 PH: 805.781.7180 CITY OF SAN LUIS OBISPO - PLANNING DEPARTMENT 919 PALM STREET SAN LUIS OBISPO, CA 93401 PH: 805.781.7170 CITY OF SAN LUIS OBISPO - PUBLIC WORKS DEPARTMENT 919 PALM STREET SAN LUIS OBISPO, CA 93401 PH: 805.781.7220 CITY OF SAN LUIS OBISPO - FIRE DEPARTMENT 2160 SANTA BARBARA AVENUE SAN LUIS OBISPO, CA 93401 PH: 805.781.7380 PG & E 406 HIGUERA STREET SAN LUIS OBISPO, CA 93401 PH: 800.743.5000 SOUTHERN CALIFORNIA GAS COMPANY 1314 BROAD STREET SAN LUIS OBISPO, CA 93401 PH: 1.800.427.2200 AGENCIES & UTILITIES OWNER KEITH SWEENEY CONTACT: KEITH SWEENEY 225 RANCHITO LANE PHONE: 415.740.4984 SLO, CA 93401 EMAIL: keith@sweeneyplumbing.com ARCHITECT TEN OVER STUDIO CONTACT: JOEL SNYDER 539 MARSH ST. PHONE: 805.541.1010 SLO, CA 93401 EMAIL: joels@tenoverstudio.com CIVIL ENGINEER BKF ENGINEERS CONTACT: JEREMY MARELLO 200 4TH STREET, SUITE 300 PHONE: 408.461.1640 SANTA ROSA, CA 95401 EMAIL: jmarello@bkf.com LANDSCAPE ARCHITECT TEN OVER STUDIO CONTACT: JULIA OBERHOFF 539 MARSH ST. PHONE: 805.541.1010 SLO, CA 93401 EMAIL: juliao@tenoverstudio.com PROJECT DIRECTORY N 101 FREEWAY PROJECT LOCATION 10 HIGUERA STREET HI G U E R A S T S H I G U E R A S T M A D O N N A R D BRIDGE ST ELKS LN THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 539 Marsh Street San Luis Obispo, CA 805.541.1010 info@tenoverstudio.com www.tenoverstudio.com NO T F O R C O N S T R U C T I O N DRWN BY: CHK'D BY: PROJ #: NOT FOR CONSTRUCTION JOEL R. SNYDER C-39262 2.28.2023 RENEWAL L I C E N S E D A RCH I T E C T S T A T E O F A L I F O R NI A C MF NM TITLE SHEET 10 H I G U E R A 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 2023-020 VICINITY MAP SHEET INDEX (ARC) GENERAL T1.0 TITLE SHEET CIVIL C1.0 EXISTING CONDITIONS C2.0 SITE DEMOLITION PLAN C3.0 SITE PLAN C4.1 GRADING AND DRAINAGE PLAN C4.2 SITE SECTIONS C5.1 UTILITY PLAN C6.1 STORMWATER CONTROL PLAN C7.1 CONSTRUCTION DETAILS LANDSCAPE L1.0 LANDSCAPE PLAN L2.0 LIGHTING PLAN L3.0 LANDSCAPE CUT SHEET ARCHITECTURE A1.0 SITE PLAN A2.0 FIRST FLOOR PLAN A2.1 SECOND FLOOR PLAN A3.0 EXTERIOR ELEVATIONS A3.1 SIGNAGE PROGRAM A4.0 PERSPECTIVE IMAGES T1.0 10 HIGUERA 10 HIGUERA ST., SAN LUIS OBISPO, CA 93401 NO. DATE SUBMITTAL 1 23.07.14 ARC INITIAL SUBMITTAL 2 24.02.06 ARC RESUBMITTAL 1 3 24.03.19 ARC RESUBMITTAL 2 Page 81 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com Page 82 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com Page 83 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com Page 84 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com Page 85 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com Page 86 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com Page 87 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com ·· · · · · · · · · · · · · Page 88 of 98 BKF ENGINEERS 200 4th STREET SUITE 300 SANTA ROSA, CA 95401 (707) 583-8500 www.bkf.com Page 89 of 98 NO PARKING NO PARKING NO PARKING NO PARKING (E) DISTILLERY KROBAR S H I G U E R A S T R E E T EXPOSITION CREEK SA N L U I S O B I S P O C R E E K (E) BREWERY CENTRAL COAST BREWING LOADING DOCK (N) DISTILLERY & WAREHOUSE STORAGE 6 4 5 1 1 1 TYP. PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINEPROPERTY LINE PR O P E R T Y L I N E TYP. 3 7 8 7 8 7 8 9 9 10 11 12 11 12 11 11 12 13 2 5 11 SYMBOL QTY BOTANICAL / COMMON NAME SIZE TREES Aesculus californica / California Buckeye 15 gal 1 Arbutus x `Marina` / Marina Strawberry Tree 24"box Quercus rubra / Red Oak 24"box BIORETENTION SHRUBS Carex praegracilis / California Field Sedge Chondropetalum tectorum 'El Campo' / El Campo Cape Rush Juncus effusus 'Carman's Japanese' / Carman's Japanese Soft Rush Juncus patens / California Gray Rush ORNAMENTAL GRASSES Lomandra longifolia 'Roma 13' / Platinum Beauty® Variegated Mat Rush Pennisetum spathiolatum / Slender Veldt Grass Sesleria autumnalis 'Campo Verde' / Campo Verde Autumn Moor Grass GROUNDCOVER PLANTING Ceanothus griseus horizontalis 'Diamond Heights' / Diamond Heights Variegated Carmel Creeper Verbena lilacina 'De la Mina' / De la Mina Lilac Verbena NATIVE SHRUBS Eriogonum giganteum / St. Catherine's Lace Frangula californica / California Coffeeberry Rhus integrifolia / Lemonade Berry FLOWERING SHRUBS Epilobium canum 'Catalina' / Catalina California Fuchsia Kniphofia x 'Gladness' / Gladness Red Hot Poker FOUNDATION SHRUBS Pennisetum spathiolatum / Slender Veldt Grass NATIVE GRASSES Calamagrostis foliosa / Reed Grass Festuca idahoensis / Idaho Fescue Muhlenbergia rigens / Deer Grass SHRUB AREAS See above. STORMWATER TREATMENT PLANTERS Carex divulsa / European Grey Sedge Chondropetalum tectorum 'El Campo' / El Campo Cape Rush Juncus effusus 'Carman's Japanese' / Carman's Japanese Soft Rush Juncus patens / California Gray Rush LANDSCAPE NOTES 1.THIS PLAN IS SCHEMATIC IN NATURE AND INTENDED TO SHOW COMPLIANCE WITH LOCAL ZONING AND DEVELOPMENT CODES. 2.ALL LANDSCAPE AREAS SHALL BE IRRIGATED WITH A PERMANENT UNDERGROUND IRRIGATION SYSTEM. IRRIGATION SYSTEM SHALL BE DESIGNED TO ADEQUATELY AND EFFICIENTLY WATER ALL SHRUB AREAS AND TREES. 3.IRRIGATION CONROLLER SHALL BE PROGRAMMABLE AND HAVE WEATHER-BASED CAPABILITIES. 4.SOIL SHALL BE AMENDED PRIOR TO PLANTING FOR OPTIMAL HEALTH OF ALL PLANT MATERIAL. SOIL AMENDMENT SPECIFICATIONS SHALL BE DETERMINED BASED ON A SOIL TEST ANALYSIS. N SCALE: 0 2010 40 1" = 20'-0"1 LANDSCAPE PLAN LANDSCAPE PLAN LEGEND KEYNOTES REFER TO CIVIL PLANS FOR MORE INFORMATION REGARDING STORMWATER TREATMENT & DRAINAGE ENTRY PLAZA BENCH, REFER TO 6 / L3.0 MECHANICAL / CHILLER PAD (E) LOADING / DELIVERY BAY FOR CENTRAL COAST BREWING (E) PUMP HOUSE (NOT A PART) TOP OF BANK 20' SETBACK FROM TOP OF CREEK BANK DG PATH TRASH ENCLOSURE ACCESSIBLE PEDESTRIAN RAMP CROSSWALK BIKE RACK - PEAK RACKS, SINGLE SIDED RACK - REFER TO 5 / L3.0 1 2 3 4 5 6 7 8 9 10 11 12 13 L1.0 LANDSCAPE PLAN 10 H I G U E R A JOEL R. SNYDER C-39262 2.28.2025 RENEWAL L I C E N S E D A R CHI T E C T S T A T E OF A L I F O R NI A C NOT FOR CONSTRUCTION NO T F O R C O N S T R U C T I O N PROJ #:2023-020 DRWN BY:JD CHK'D BY:NM 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 10 H I G U E R A info@tenoverstudio.com 805.541.1010 www.tenoverstudio.com San Luis Obispo, CA 539 Marsh Street THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 PLANT SCHEDULE PLANT SCHEDULE ASPHALT PAVING CONCRETE PAVING DG OR GRAVEL ACCENT CONCRETE PAVING PROPOSED 6' TALL, HORIZONTAL WOOD FENCE MWELO IRRIGATION CALCULATION NO.DATE SUBMITTAL 1 23.07.14 ARC INITIAL SUBMITTAL 2 24.02.06 ARC RESUBMITTAL 1 3 24.03.19 ARC RESUBMITTAL 2 4 24.61.18 PLANNING HEARING 15 2 18 Page 90 of 98 NO PARKING NO PARKING NO PARKING NO PARKING (E) DISTILLERY KROBAR S H I G U E R A S T R E E T EXPOSITION CREEK SA N L U I S O B I S P O C R E E K (E) BREWERY CENTRAL COAST BREWING LOADING DOCK S1 S1 S1 S2 S2 S1 S1 S1 S1 S1 S1 S1 S1S1S1 S4 S4 S4 S1 S2 S3 S3 S3 S3 S3 S3 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 S5 S4 (N) DISTILLERY & WAREHOUSE STORAGE D-SERIES SIZE 0 AREA LUMINAIRE P3 PERFORMANCE PACKAGE TYPE 3 EXTREME BACKLIGHT CONTROL SYBMOL QTY.DESCRIPTION 14 6 4 MODEL LITHONIA LIGHTING 3 LITHONIA LIGHTING LITHONIA LIGHTING BEGA D-SERIES SIZE 0 AREA LUMINAIRE P3 PERFORMANCE PACKAGE 4000K CCT 80 CRI TYPE 3 MEDIUM WDGE2 LED WITH P2SW - PERFORMANCE PACKAGE, 4000K, 80CRI, VISUAL COMFORT FORWARD OPTIC S1 S2 S3 S4 13 LOW LEVEL BOLLARDS5 SURFACE MOUNTED CYLINDER BEGA N SCALE: 0 2010 40 1" = 20'-0"1 LIGHTING PLAN L2.0 LIGHTING PLAN LIGHTING PLAN GENERAL NOTES 1.REFER TO SHEET L3.0 FOR LIGHTING PRODUCT CUT SHEETS. 2.REFER TO PHOTOMETRIC LIGHTING PLAN PROVIDED BY MVS FOR MORE INFORMATION REGARDING PHOTOMETRIC VALUES AND PRODUCT INFORMATION. 10 H I G U E R A JOEL R. SNYDER C-39262 2.28.2025 RENEWAL L I C E N S E D A R CHI T E C T S T A T E OF A L I F O R NI A C NOT FOR CONSTRUCTION NO T F O R C O N S T R U C T I O N PROJ #:2023-020 DRWN BY:JD CHK'D BY:NM 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 10 H I G U E R A info@tenoverstudio.com 805.541.1010 www.tenoverstudio.com San Luis Obispo, CA 539 Marsh Street THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 LIGHTING SCHEDULE NO.DATE SUBMITTAL 1 23.0.14ARC INITIAL SUBMITTAL 2 24.02.06 ARC RESUBMITTAL 1 3 24.03.19 ARC RESUBMITTAL 2 4 24.61.18 PLANNING HEARING Page 91 of 98 1 S1 & S2 LIGHT FIXTURE REFER TO SHEET L2.0 FOR LIGHTING SCHEDULE & PLAN L3.0 LANDSCAPE CUT SHEETS 10 H I G U E R A JOEL R. SNYDER C-39262 2.28.2025 RENEWAL L I C E N S E D A R CHI T E C T S T A T E OF A L I F O R NI A C NOT FOR CONSTRUCTION NO T F O R C O N S T R U C T I O N PROJ #:2023-020 DRWN BY:JD CHK'D BY:NM 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 10 H I G U E R A info@tenoverstudio.com 805.541.1010 www.tenoverstudio.com San Luis Obispo, CA 539 Marsh Street THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 2 S3 LIGHT FIXTURE REFER TO SHEET L2.0 FOR LIGHTING SCHEDULE & PLAN 6 BENCH 3 S4 LIGHT FIXTURE REFER TO SHEET L2.0 FOR LIGHTING SCHEDULE & PLAN4S5 BOLLARD REFER TO SHEET L2.0 FOR LIGHTING SCHEDULE & PLAN 5 NOT USED NO.DATE SUB0ITTAL 1 23.0.14ARC INITIAL SUB0ITTAL 2 24.02.06 ARC RESUB0ITTAL 1 3 24.03.1ARC RESUB0ITTAL 2 4 24.61.13LANNING HEARING Page 92 of 98 NO PARKING VA-EVR EV CAPABLEEV CAPABLE EV CAPABLE EV CAPABLE EV CAPABLE EV CH A R G I N G ONLY EV CH A R G I N G ONLY EV CH A R G I N G ONLY EV CH A R G I N G ONLY EV CH A R G I N G ONLY S-EVR S-EVR S-EVR S-EVR S-EVR S-EVRS-EVR EV CHARGING ONLY EV CHARGING ONLYEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLEEV CAPABLE S-EVCS-EVCS-EVCS-EVCS-EVCS-EVCS-EVCS-EVCS-EVCS-EVCS-EVCC-EVCC-EVCC-EVCC-EVCC-EVCC-EVCC-EVC NO PARKING EV CHARGING ONLY S-EVC EV CAPABLE (E) DISTILLERY KROBAR S H I G U E R A S T R E E T EXPOSITION CREEK SA N L U I S O B I S P O C R E E K (E) BREWERY CENTRAL COAST BREWING LOADING DOCK 1 2 3 3 5 6 TYP. 7 8 9 1 2 126'-1"38'-4" 1 A8.2 (N) DISTILLERY & WAREHOUSE RESTAURANT & BAR APPROX. 21,140 SF 10 (E) PARKING 30 SPACES PROPOSED PARKING 78 TOTAL SPACES 11 C-S ZONE DESIGNATION C-T ZONE DESIGNATION 12 13 14 15 10 ' - 0 " 16 18 17 2ND FLOOR RES. UNIT APPROX. 660 SF 2ND FLOOR TASTING & OFFICES APPROX. 4995 SF 19 4 4 16 2020 21 21 22 23 24 24 24 24 24 N SCALE: 0 2010 40 1" = 20'-0"1 SITE PLAN ARCHITECTURAL SITE PLAN LEGEND LANDSCAPE AREA (E) PROPERTY LINE, REFER TO ATTACHED LOT LINE ADJUSTMENT DOCUMENT KEYNOTES TOP OF CREEK BANK LINE 20' SETBACK LINE FROM TOP OF CREEK BANK (E) DRIVEWAY, NOT A PART OF THIS PROJECT LONG TERM BIKE PARKING (8 TOTAL), 2 EA TRASH ENCLOSURE TO COMPLY WITH CITY OF SAN LUIS OBISPO CITY ENGINEERING STANDARDS BY PROVIDING ADEQUATE SIZING TO STORE REQUIRED CONTAINERS FOR WASTE, RECYCLING, ORGANICS, AND FOG, PER CITY BIN ENCLOSURE DRAWINGS AND SLO MUNICIPAL CODE 17.70.200 TRASH ENCLOSURE STANDARDS. SHORT TERM BIKE PARKING, PEAK RACK OR SIMILAR "U" STYLE RACK, (20), 5 EA BACK-IN RAMP TO LOADING DOCK MECHANICAL PAD, UNDER FUTURE TENANT IMPROVEMENT PERMIT (E) PUMP HOUSE TO REMAIN, NOT IN SCOPE FLAG POLE FIRE RISER PRELIMINARY LOCATION; FINAL ROOM LOCATION AND RISER SHALL BE LOCATED FOR BUILDING PERMIT APPLICATION SUBMITTAL (E) ZONE BOUNDARY, REFER TO ATTACHED LOT LINE ADJUSTMENT DOCUMENT EXTENT OF FUTURE BOB JONES TRAIL EASEMENT THROUGH SITE (N) TRANSFORMER PG&E EASEMENT UTILITY POLE TO REMAIN, PROTECT IN PLACE DECOMPOSED GRANITE 6' FOOT TALL DECORATIVE LANDSCAPE FENCING AT OUT DOOR AREA SWITCHGEAR LOCATION BOLLARD AND CHAIN LOCATION AT OVERFLOW PARKING. OVERFLOW PARKING SHALL REMAIN CLOSED WITH CHAIN DEPLOYED DURING STORM EVENTS (E) PERUVIAN PEPPER TREE TO BE REMOVED, PLEASE SEE ARBORIST REPORT FOR TREE REMOVAL AND TREE PROTECTION INFORMATION CONCRETE STAIRS WITH HANDRAIL ACCESS TO PG&E EASEMENT ON NORTHERN PROPERTY LINE (N) LOCATION OF FUTURE ELECTRICAL VEHICLE CHARGING STATION (EVCS) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A1.0 SITE PLAN ARCHITECTURAL SITE PLAN GENERAL NOTES 1.REFER TO SHEET T1.0 FOR PARKING REQUIREMENTS AND CALCULATIONS. 2.REFER TO CIVIL ENGINEERING PLANS FOR EXISTING CONDITIONS AND DEMOLITION PLANS. 3.REFER TO LANDSCAPE PLANS FOR MORE INFORMATION REGARDING PLANTING, SITE LIGHTING, AND HARDSCAPE 10 H I G U E R A JOEL R. SNYDER C-39262 2.28.2025 RENEWAL L I C E N S E D A R CHI T E C T S T A T E OF A L I F O R NI A C NOT FOR CONSTRUCTION NO T F O R C O N S T R U C T I O N PROJ #:2023-020 DRWN BY:JD CHK'D BY:NM 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 10 H I G U E R A NO.DATE SUBMITTAL info@tenoverstudio.com 805.541.1010 www.tenoverstudio.com San Luis Obispo, CA 539 Marsh Street THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 1 23.07.14 ARC INITIAL SUBMITTAL 2 24.02.06 ARC RESUBMITTAL 1 3 24.03.19 ARC RESUBMITTAL 2 STORMWATER TREATMENT LANDSCAPE AREA (E) CREEK / BUILDING SETBACK LINE (N) FENCE - 6' TALL, COATED CHAIN LINK, COLOR: BLACK FLOOD SHADOW SITE ARRIVAL POINT PATH OF TRAVEL FROM SIDEWALK AND EXIT DISCHARGE ROUTE PATH OF TRAVEL (E) ZONE BOUNDARY, REFER TO ATTACHED LOT LINE ADJUSTMENT DOCUMENT CONCRETE AT ENTRY PLAZA 4 24.61.18 PLANNING HEARING Page 93 of 98 UP UP UP 48 ' - 4 1 / 2 " 1 1 ' - 5 1 / 2 " 11 ' - 8 " 8'-10" 14'-5" 9'-3"9'-3" 30'-6" 10'-6" 12'-0" 15 ' - 0 " 19 ' - 0 " 18'-5" 22.001 22.002 08.003 08.003 01.001 245'-0" 10.001 7' - 0 " 22.001 22.003 21 ' - 0 " 01.006 01.010 20'-0" 23.002 01.007 265'-0" 19 ' - 6 " 2 4 ' - 6 " 01.003 08.003 79'-10 1/2"30'-5" TYP. 01.005 22.004 8'-7" 7308 SF WAREHOUSE STORAGE 101 7369 SF DISTILLERY 105 479 SF STILL TOWER 111 124 SF M RR 116 124 SF W RR 117 77 SF SHOWER 112 74 SF RR 114 180 SF LOCKER ROOM 102 252 SF OFFICE 103 67 SF WALK-IN 119A 1007 SF BOTTLING ROOM 106 69 SF RR 104 COVERED EXTERIOR LOADING EGRESS STAIR 2 EGRESS STAIR 1 ELEVATOR 47 SF ELEVATOR MACHINE ROOM 115 43 SF FREEZER 90 ' - 6 " 8' - 2 " 13 ' - 1 " W1 14.001 W1 W1 W1 W1 W1 W1W1 W1 W1 W1 8' - 0 " 9' - 8 3 / 8 " 720 SF KITCHEN 119 21 ' - 2 " 8' - 6 " 684 SF LOUNGE 120 270 SF BAR 121 614 SF DINING 118 256 SF HOST 122 4' - 0 " 8'-0" 22.006 26.002 46'-0"39'-3 3/8" 12.001 08.004 12.001 22 ' - 0 " 08.003 TYP. 01.004 61 SF STORAGE 123 22.003 FLOOR PLAN GENERAL NOTES B. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36" MEASURED IN THE DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCEED 2%. EXTERIOR BALCONIES LESS THAN 60 S.F. AND ONLY ACCESSIBLE FROM A DOOR ARE PERMITTED TO HAVE A LANDING LESS THAN 36" DEEP. REFER TO CRC R311.3. C. LANDINGS OR FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-1/2" LOWER THAN THE TOP OF THE THRESHOLD. THE EXTERIOR LANDING OR FLOOR SHALL NOT BE MORE THAN 7-3/4" BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. WHEN EXTERIOR LANDINGS OR FLOORS SERVING THE REQUIRED EGRESS DOOR ARE NOT AT GRADE, THEY SHALL BE PROVIDED WITH ACCESS TO GRADE BY MEANS OF A RAMP IN ACCORDANCE WITH SECTION R311.8 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.7. D. DOORS OTHER THEN THE REQUIRED EGRESS DOOR SHALL BE PROVIDED WITH LANDINGS OR FLOORS NOT MORE THAN 7-3/4" BELOW THE TOP OF THE THRESHOLD. A LANDING IS NOT REQUIRED WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF THE DOOR, PROVIDED THE DOOR DOES NOT SWING OVER THE STAIRWAY. E. STORM AND SCREEN DOORS SHALL BE PERMITTED TO SWING OVER ALL EXTERIOR STAIRS AND LANDINGS. 12. DO NOT SCALE DRAWINGS. ALL DIMENSIONS ARE ROUGH AND TO FACE OF STUD (F.O.S.). 13. ALL DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION IS FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY THE ARCHITECT / DESIGNER IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM ARCHITECT / DESIGNER PRIOR TO PROCEEDING WITH ANY WORK. 1. TOILET ROOMS SHALL HAVE EXHAUST RATE OF 50 CFM MINIMUM. 2. ELECTRICAL OUTLETS TO BE PLACED AT 18" TO CENTERLINE ABOVE FINISH FLOOR U.N.O. 3. ELECTRICAL SWITCHES TO BE PLACED AT 48" TO CENTERLINE FROM FINISH FLOOR U.N.O. 4. DOORS HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MINIMUM 34" AND A MAXIMUM 48" A.F.F. 5. ALL EXTERIOR WALL SHALL BE 2X FRAMING WITH R-13 MINIMUM INSULATION OR PER TITLE 24, U.N.O. REFER TO WALL LEGEND. 6. ALL INTERIOR WALLS SHALL BE 2X4 FRAMING, TYPICAL U.N.O. REFER TO WALL LEGEND. 7. ALL PLUMBING WALLS SHALL BE 2X6 MINIMUM FRAMING. REFER TO WALL LEGEND. 8. PROVIDE R-13 MINIMUM INSULATION AT PLUMBING WALLS AND WALLS OF LAUNDRY ROOM. 9. PROVIDE 1" MINIMUM AIR SPACE BETWEEN WOOD STRUCTURES AND RETAINING WALLS. 10. PROVIDE 1 MIRROR, 1 TOILET PAPER HOLDER, 1 HAND TOWEL BAR, AND 2 BATH TOWEL BARS PER BATHROOM. 11. THRESHOLD AND LANDINGS A. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3/4" IN HEIGHT FOR SLIDING DOORS SERVING DWELLING UNITS OR 1/2" FOR OTHER DOORS. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1/4" AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50% SLOPE). THE THRESHOLD HEIGHT SHALL BE LIMITED TO 7- 3/4" AND THE DOOR IS AN EXTERIOR DOOR THAT IS NOT A COMPONENT OF THE REQUIRED MEANS OF EGRESS; THE DOOR DOES NOT SWING OVER THE LANDING OR STEP; AND THE DOORWAY IS NOT ON AN ACCESSIBLE ROUTE AND IS NOT PART OF AN ADAPTABLE OR ACCESSIBLE DWELLING UNIT. REFER TO CBC 1008.1.7. EXTERIOR WALL ASSEMBLY SCHEDULE TYPE DESCRIPTION W1 FIRE RATED WALL EXTERIOR SIDEWALK; DRAIN AWAY FROM BUILDING WHERE OCCURS FOUNDATION PER STRUCTURAL EXPANSION JOINT FILLER WALL ASSEMBLY PER PLAN 4" LIGHT-GAUGE STEEL FRAMING CONTINUOUS SILICONE SEALANT BUILDING SLAB PER STRUCTURAL BACKER ROD & SEALANT FLOODPROOFING WALL ASSEMBLY CORRUGATED VERTICAL METAL SIDING RUBBER COAT BRUSH APPLIED WATERPROOFING1/2" PLYWOOD SHEATHING, TAPE ALL JOINTS STEEL ANGLE CLIP PER STRUCTURAL VERTICAL CORRUGATED METAL TO MATCH THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 539 Marsh Street San Luis Obispo, CA 805.541.1010 info@tenoverstudio.com www.tenoverstudio.com NO T F O R C O N S T R U C T I O N DRWN BY: CHK'D BY: PROJ #: NOT FOR CONSTRUCTION JOEL R. SNYDER C-39262 2.28.2023 RENEWAL L I C E N S E D A RCH I T E C T S T A T E O F A L I F O R NI A C MF NM FIRST FLOOR PLAN 10 H I G U E R A 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 2023-020 1/8" = 1'-0"1 FLOOR PLAN KEYNOTES 01.001 DASHED OVERHEAD LINE INDICATES EXTENT OF SECOND FLOOR 01.003 DASHED LINE INDICATES CATWALK OVERLOOKING THE STILL TOWER 01.004 DASHED LINE INDICATES PALLET STORAGE, SPIRIT HOLDING TANKS AND FERMENTING TANKS 01.005 DASHED LINE INDICATES PALLET STORAGE 01.006 BAR AND BAR SEATING 01.007 ADA BAR, MAXIMUM HEIGHT OF 34" 01.010 LIQUOR STILL 08.003 OVERHEAD ROLL-UP DOOR 08.004 DOUBLE SWINGING KITCHEN DOOR 10.001 METAL LOCKERS, TYPE AND MANUFACTURER TBD 12.001 BUILT-IN BOOTH SEATING 14.001 ELEVATOR, TYPE AND MANUFACTURER TBD 22.001 ACCESSIBLE FLOOR-MOUNTED TOILET WITH GRAB BARS 22.002 WALL-MOUNTED URINAL 22.003 COUNTER-MOUNTED LAVATORY WITH REQUIRED KNEE AND TOE CLEARANCES PROVIDED 22.004 ACCESSIBLE ROLL-IN SHOWER WITH FOLDING SEAT AND TRANSFER AND CLEAR SPACE PROVIDED 22.006 FIRE RISER PRELIMINARY LOCATION; FINAL ROOM LOCATION AND RISER SHALL BE LOCATED FOR BUILDING PERMIT APPLICATION SUBMITTAL 23.002 TYPE 1 HOOD OVERHEAD 26.002 ELECTRICAL SWITCHGEAR; SEE ELECTRICAL DRAWINGS A2.01 1/2" = 1'-0"2 FLOODPROOFING @ EXTERIOR WALL NO. DATE SUBMITTAL 1 23.07.14 ARC INITIAL SUBMITTAL 24.02.06 ARC RESUBMITTAL 12 3 24.03.19 ARC RESUBMITTAL 2 4 24.61.18 PLANNING HEARING Page 94 of 98 DN DN DN 15'-10" 11 ' - 6 1 / 2 " 10'-0 3/4"10'-0 1/8"8'-7 1/2" 7'- 6 " 11 ' - 8 3 / 4 " 12 ' - 4 " 11 ' - 8 " 5'-6" TYP. 08.001 TYP. 22.003 TYP. 22.001 23.001 01.006 01.002 15'-10" 01.007 01.010 221 SF BRAND EDUCATION 204 78 SF W RR 209 208 SF ELEVATOR LOBBY 201 221 SF BRAND EDUCATION 205 219 SF BRAND EDUCATION 206 115 SF STILL TOWER ELEVATOR 90 ' - 6 " 19 ' - 0 " TYP. 14.001 7'- 1 0 " W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 298 SF LIVING & KITCHEN 211 167 SF BEDROOM 212 43 SF CLOSET 213 46 SF BATHROOM 214 37 SF POWDER 215 78 SF M RR 210 192 SF BRAND EDUCATION 202 195 SF BRAND EDUCATION 203 305 SF CONFERENCE ROOM 220 134 SF OFFICE 216 134 SF OFFICE 217 183 SF OFFICE 218 76 SF STORAGE 219 5' - 6 " 9'- 1 0 " 6'-0" 29'-11 1/2" 3'-6" 18 ' - 4 " 1187 SF TASTING ROOM 207 FLOOR PLAN GENERAL NOTES B. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36" MEASURED IN THE DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCEED 2%. EXTERIOR BALCONIES LESS THAN 60 S.F. AND ONLY ACCESSIBLE FROM A DOOR ARE PERMITTED TO HAVE A LANDING LESS THAN 36" DEEP. REFER TO CRC R311.3. C. LANDINGS OR FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-1/2" LOWER THAN THE TOP OF THE THRESHOLD. THE EXTERIOR LANDING OR FLOOR SHALL NOT BE MORE THAN 7-3/4" BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. WHEN EXTERIOR LANDINGS OR FLOORS SERVING THE REQUIRED EGRESS DOOR ARE NOT AT GRADE, THEY SHALL BE PROVIDED WITH ACCESS TO GRADE BY MEANS OF A RAMP IN ACCORDANCE WITH SECTION R311.8 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.7. D. DOORS OTHER THEN THE REQUIRED EGRESS DOOR SHALL BE PROVIDED WITH LANDINGS OR FLOORS NOT MORE THAN 7-3/4" BELOW THE TOP OF THE THRESHOLD. A LANDING IS NOT REQUIRED WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF THE DOOR, PROVIDED THE DOOR DOES NOT SWING OVER THE STAIRWAY. E. STORM AND SCREEN DOORS SHALL BE PERMITTED TO SWING OVER ALL EXTERIOR STAIRS AND LANDINGS. 12. DO NOT SCALE DRAWINGS. ALL DIMENSIONS ARE ROUGH AND TO FACE OF STUD (F.O.S.). 13. ALL DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION IS FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY THE ARCHITECT / DESIGNER IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM ARCHITECT / DESIGNER PRIOR TO PROCEEDING WITH ANY WORK. 1. TOILET ROOMS SHALL HAVE EXHAUST RATE OF 50 CFM MINIMUM. 2. ELECTRICAL OUTLETS TO BE PLACED AT 18" TO CENTERLINE ABOVE FINISH FLOOR U.N.O. 3. ELECTRICAL SWITCHES TO BE PLACED AT 48" TO CENTERLINE FROM FINISH FLOOR U.N.O. 4. DOORS HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MINIMUM 34" AND A MAXIMUM 48" A.F.F. 5. ALL EXTERIOR WALL SHALL BE 2X FRAMING WITH R-13 MINIMUM INSULATION OR PER TITLE 24, U.N.O. REFER TO WALL LEGEND. 6. ALL INTERIOR WALLS SHALL BE 2X4 FRAMING, TYPICAL U.N.O. REFER TO WALL LEGEND. 7. ALL PLUMBING WALLS SHALL BE 2X6 MINIMUM FRAMING. REFER TO WALL LEGEND. 8. PROVIDE R-13 MINIMUM INSULATION AT PLUMBING WALLS AND WALLS OF LAUNDRY ROOM. 9. PROVIDE 1" MINIMUM AIR SPACE BETWEEN WOOD STRUCTURES AND RETAINING WALLS. 10. PROVIDE 1 MIRROR, 1 TOILET PAPER HOLDER, 1 HAND TOWEL BAR, AND 2 BATH TOWEL BARS PER BATHROOM. 11. THRESHOLD AND LANDINGS A. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3/4" IN HEIGHT FOR SLIDING DOORS SERVING DWELLING UNITS OR 1/2" FOR OTHER DOORS. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1/4" AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50% SLOPE). THE THRESHOLD HEIGHT SHALL BE LIMITED TO 7- 3/4" AND THE DOOR IS AN EXTERIOR DOOR THAT IS NOT A COMPONENT OF THE REQUIRED MEANS OF EGRESS; THE DOOR DOES NOT SWING OVER THE LANDING OR STEP; AND THE DOORWAY IS NOT ON AN ACCESSIBLE ROUTE AND IS NOT PART OF AN ADAPTABLE OR ACCESSIBLE DWELLING UNIT. REFER TO CBC 1008.1.7. EXTERIOR WALL ASSEMBLY SCHEDULE TYPE DESCRIPTION W1 FIRE RATED WALL THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 539 Marsh Street San Luis Obispo, CA 805.541.1010 info@tenoverstudio.com www.tenoverstudio.com NO T F O R C O N S T R U C T I O N DRWN BY: CHK'D BY: PROJ #: NOT FOR CONSTRUCTION JOEL R. SNYDER C-39262 2.28.2023 RENEWAL L I C E N S E D A RCH I T E C T S T A T E O F A L I F O R NI A C MF NM SECOND FLOOR PLAN 10 H I G U E R A 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 2023-020 1/8" = 1'-0"1 SECOND FLOOR PLAN KEYNOTES 01.002 DASHED OVERHEAD LINE INDICATES ROOF LINE ABOVE 01.006 BAR AND BAR SEATING 01.007 ADA BAR, MAXIMUM HEIGHT OF 34" 01.010 LIQUOR STILL 08.001 ALUMINUM STOREFRONT SYSTEM 14.001 ELEVATOR, TYPE AND MANUFACTURER TBD 22.001 ACCESSIBLE FLOOR-MOUNTED TOILET WITH GRAB BARS 22.003 COUNTER-MOUNTED LAVATORY WITH REQUIRED KNEE AND TOE CLEARANCES PROVIDED 23.001 CHASE PROVIDED FOR VENTING AND HVAC A2.1 NO. DATE SUBMITTAL 1 23.07.14 ARC INITIAL SUBMITTAL 24.02.06 ARC RESUBMITTAL 12 3 24.03.19 ARC RESUBMITTAL 2 4 24.61.18 PLANNING HEARING Page 95 of 98 GROUND FLOOR0" SECOND FLOOR (MEZZANINE) 14'-6" TOP OF TOWER ROOF40'-0" TOP OF UPPER ROOF33'-5" TYP. 08.002 TYP. 05.003 SECOND FLOOR (RES. UNIT)10'-6" GROUND FLOOR0" SECOND FLOOR (MEZZANINE) 14'-6" TOP OF TOWER ROOF40'-0" TOP OF UPPER ROOF 33'-5" TOP OF LOWER ROOF25'-5" TYP. 05.005 TYP. 05.00308.002 SECOND FLOOR (RES. UNIT)10'-6" 08.003 GROUND FLOOR0" TOP OF TOWER ROOF40'-0" TOP OF UPPER ROOF33'-5" TOP OF LOWER ROOF 25'-5" TYP. 05.001 SECOND FLOOR (RES. UNIT)10'-6" EXTERIOR ELEVATION GENERAL NOTES 1.EXTERIOR FINISHES AND COLORS SHALL BE VERIFIED WITH THE OWNER PRIOR TO APPLICATION, WHETHER SPECIFIED ON THE PLANS OR NOT. 2.PROVIDE FLASHING AND COUNTERFLASHING PER CBC 1707 AT CHIMNEYS, PARAPETS, BALCONIES, LANDINGS, EXTERIOR STAIRWAYS, ROOF TO WALL INTERSECTIONS, AND ANY OTHER VERTICAL TO HORIZONTAL INTERSECTIONS TO MAINTAIN A WEATHER AND WATER TIGHT ENVELOPE. FLASHING AND COUNTERFLASHING SHALL BE MIN. 26 GA. GALV. METAL. PAINT ALL GALV. METAL MATERIAL TO MATCH ADJACENT MATERIAL 3.GUTTER AND DOWNSPOUTS SHALL BE INSTALLED ON ALL ROOF AREAS UNO. ALL GUTTERS SHALL BE GALVANIZED METAL OR ALUMINUM, PAINTED TO MATCH FASCIA. DOWNSPOUTS SHALL BE PAINTED TO MATCH ADJACENT WALL FINISH UNO AND TIED INTO UNDERGROUND DRAINAGE. REFER TO GRADING/DRAINAGE PLAN (IF PROVIDED) FOR ADDITIONAL INFORMATION 4.GUTTERS SHALL INCLUDE AN INTEGRAL MEANS OF PREVENTING ACCUMULATION OF LEAVES AND DEBRIS. VERTICAL BOX RIB METAL SIDING; AEP SPAN, COOL DURA TECH 5000 MATTE BLACK EXTERIOR ELEVATION LEGEND STANDING SEAM METAL ROOFING; AEP SPANSEAM, COOL DURA TECH 5000 SLATE GRAY VERTICAL WOOD SIDING; NATURAL STAIN ALUMINUM STOREFRONT WINDOW FRAMES, MULLIONS AND DOOR FRAMES; ANODIZED DARK BRONZE EXTERIOR DOWNLIT WALL SCONCE IN COMPLIANCE WITH DARK SKY REQUIREMENTS; DARK BRONZE CONCRETE BASE, BOARD FINISHED GROUND FLOOR 0" SECOND FLOOR (MEZZANINE)14'-6" TOP OF TOWER ROOF40'-0" TOP OF UPPER ROOF 33'-5" TOP OF LOWER ROOF25'-5" SECOND FLOOR (RES. UNIT) 10'-6" 08.003 THESE DRAWINGS ARE INSTRUMENTS OF SERVICEAND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 539 Marsh Street San Luis Obispo, CA 805.541.1010 info@tenoverstudio.com www.tenoverstudio.com NO T F O R C O N S T R U C T I O N DRWN BY: CHK'D BY: PROJ #: NOT FOR CONSTRUCTION JOEL R. SNYDER C-39262 2.28.2023 RENEWAL L I CE N S E D A R CHI T E C T S T A T E OF A L I F O RNI A C MF NM EXTERIOR ELEVATIONS 10 H I G U E R A 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 2023-020 1/8" = 1'-0"2 EAST ELEVATION 1/8" = 1'-0"1 SOUTH ELEVATION 1/8" = 1'-0"3 WEST ELEVATION KEYNOTES 05.001 EXTERIOR STEEL COLUMN, PAINTED BLACK 05.003 EXTERIOR STEEL AWNING 05.005 EXTERIOR STEEL SCREENING 08.002 ALUMINUM STOREFRONT ENTRANCE DOORS 08.003 OVERHEAD ROLL-UP DOOR A3.0 NO.DATE SUBMITTAL 1 23.07.14 ARC INITIAL SUBMITTAL 2 24.02.06 ARC RESUBMITTAL 1 1/8" = 1'-0"4 NORTH ELEVATION 3 24.03.19 ARC RESUBMITTAL 2 4 24.61.18 PLANNING HEARING Page 96 of 98 SIGNAGE PROGRAM GENERAL NOTES 1.SIGNAGE IS ONLY PERMITTED IN ZONES INDICATED IN ELEVATION DRAWINGS ABOVE. 2.ALL SIGNAGE SHALL FOLLOW GUIDELINES LISTED IN EACH RESPECTIVE ZONE'S NOTES ON THOSE ELEVATIONS INCLUDING SIGNAGE TYPES, NUMBER, DESIGN, SIZE, MATERIALS, COLOR, ILLUMINATION, AND INSTALLATION . 3.ALL SIGNAGE TYPES, DIMENSIONS, AND SPECIFICATIONS ARE BASED ON CHAPTER 15.40 "SIGN REGULATIONS" AND SECTION 15.40.460 ("SIGN STANDARDS BY DISTRICT") TABLE UNDER C-T AND C-S ZONING DESIGNATION AND SECTION 15.40.460 ("SIGN STANDARDS BY SIGN TYPE") WITH ADJUSTMENTS PER PROJECT PROGRAM AND DESIGN. 4. ALL SIGNS WILL COMPLY WITH ILLUMINATION REGULATIONS IN SAN LUIS OBISPO MUNICIPAL CODE SECTION 15.40.430. 5 . ALL SIGNS WILL COMPLY WITH DESIGN PRINCIPLES IN SAN LUIS OBISPO MUNICIPAL CODE SECTION 15.40.480. GROUND FLOOR0" SECOND FLOOR (MEZZANINE) 14'-6" TOP OF TOWER ROOF40'-0" TOP OF UPPER ROOF 33'-5" SIGN ZONE 1 TYPES PERMITTED: WALL-MOUNTED SIGNS NUMBER: 1 SIGN MAXIMUM MAXIMUM SIZE: 150 SF TOTAL DESIGN: THREE-DIMENSIONAL LETTERING AND/OR LOGO BALANCED AND IN PROPORTION TO SCALE WITH BUILDING ELEVATION WITH COMPOSITION THAT DOES NOT OVERWHELM OR OBSCURE DESIGN. MATERIAL: HIGH QUALITY AND DURABLE MATERIALS THAT ARE COMPLEMENTARY AND/OR SIMILAR TO BUILDING MATERIALS AND DO NOT DISTRACT FROM OF OVERWHELM DESIGN OR OVERALL BUILDING FORM. SIGN MATERIALS SHALL CONVEY A SENSE OF PERMANENCE AND DURABILITY, AND NOT CONSIST OF FOAM, POSTER BOARD, FLAT PLASTIC, OR ANY OTHER MATERIAL INDICATING TEMPORARY SIGNAGE. COLOR: ALL COLORS SHOULD BE COMPLEMENTARY TO BUILDING MATERIALS AND COLOR. ILLUMINATION: EXTERNAL OR INTERNAL PERMITTED CONSISTENT W/SLO MUNI CODE SECTION 15.40.430 INSTALLATION: HIGH QUALITY INSTALLATION USING A DIRECT OR FLUSH MOUNT WITHOUT EXPOSED WIRING, RACEWAYS, OR OTHER STABLIZING DEVICES INCLUDING BACKER MOUNTS. ATTACHMENTS SHALL BE HIDDEN FROM VIEW IN LEAST DESTRUCTIVE MANNER POSSIBLE. MIN. 1'-6" SIGN ZONE 2 TYPES PERMITTED: HANGING & SUSPENDED, OR AWNING IF APPLICABLE NUMBER: 1 SIGN MAXIMUM MAXIMUM SIZE: SIZE OF SIGNS SHALL BE PEDESTRIAN SCALE, IN PROPORTION WITH BUILDING, AND NOT NEGATIVELY OBSCURE TRANSPARENCY INTO BUILDING AT GLASS FACADE ELEMENTS. REFER TO SLO MUNI CODE SECTION 15.40.470 FOR GENERAL SIZE PARAMETERS. DESIGN: HANGING & SUSPENDED DESIGNED IN A CONSISTENT MANNER. ALL SIGNAGE SHALL BE THREE DIMENSIONAL (NOT ENTIRELY FLAT OR SIMPLY PAINTED) IN PROPORTION TO SCALE WITH BUILDING ELEVATION WITH COMPOSITION THAT DOES NOT OVERWHELM OR OBSCURE DESIGN. ANY ADDITIONAL ELEMENTS ADDED FOR SIGNAGE (AWNINGS, STRUCTURE, ETC...) MUST BE COHESIVELY INCORPORATED INTO BUILDING DESIGN IN TERMS OF FORM, SIZE, AND MATERIAL. MATERIAL: HIGH QUALITY AND DURABLE MATERIALS THAT ARE COMPLEMENTARY AND/OR SIMILAR TO BUILDING MATERIALS AND DO NOT DISTRACT FROM OF OVERWHELM DESIGN OR OVERALL BUILDING FORM. SIGN MATERIALS SHALL CONVEY A SENSE OF PERMANENCE AND DURABILITY, AND NOT CONSIST OF FOAM, POSTER BOARD, FLAT PLASTIC, OR ANY OTHER MATERIAL INDICATING TEMPORARY SIGNAGE. COLOR: ALL COLORS SHOULD BE COMPLEMENTARY TO BUILDING MATERIALS AND COLOR. ILLUMINATION: EXTERNAL OR INTERNAL PERMITTED CONSISTENT W/SLO MUNI CODE SECTION 15.40.430 INSTALLATION: HIGH QUALITY INSTALLATION WITHOUT EXPOSED WIRING, RACEWAYS, OR OTHER STABLIZING DEVICES INCLUDING BACKER MOUNTS. ATTACHMENTS SHALL BE HIDDEN FROM VIEW IN LEAST DESTRUCTIVE MANNER POSSIBLE. ADDITIONAL REQUIREMENTS: ALL SIGNS MUST MAINTAIN MINIMUM VERTICAL AND HORIZONTAL CLEARANCE REQUIREMENTS OF SLO MUNI CODE SECTION 15.40.440. 8'- 4 " M I N . TYPES PERMITTED: WINDOW SIGNS NUMBER: 1 SIGN PER WINDOW MAXIMUM SIZE: SIZE OF SIGNS SHALL BE PEDESTRIAN SCALE, IN PROPORTION WITH BUILDING, AND NOT NEGATIVELY OBSCURE VIEW TO INTERIOR AT GLASS. REFER TO SLO MUNI CODE SECTION 15.40.470 FOR GENERAL SIZE PARAMETERS. DESIGN: SIGNS SHALL BE LIMITED TO SMALL GRAPHICS AND TEXT THAT SERVE TO FRAME A WINDOW OR PROVIDE INFORMATION. WINDOW SIGNS ARE LOCATED WITHIN 36 INCHES OF A WINDOW. SIGNS SHOULD CLEARLY RELATE TO THEIR TENANT SPACE. TYPICALLY WINDOW SIGNS ARE TWO-DIMENSIONAL SIGNS ADHERED TO GLASS OF WINDOWS OR DOORS. MATERIAL: HIGH QUALITY AND DURABLE MATERIALS THAT ARE COMPLEMENTARY AND/OR SIMILAR TO BUILDING MATERIALS AND DO NOT DISTRACT FROM OF OVERWHELM DESIGN OR OVERALL BUILDING FORM. SIGN MATERIALS SHALL CONVEY A SENSE OF PERMANENCE AND DURABILITY, AND NOT CONSIST OF FOAM, POSTER BOARD, FLAT PLASTIC, OR ANY OTHER MATERIAL INDICATING TEMPORARY SIGNAGE. COLOR: ALL COLORS SHOULD BE COMPLEMENTARY TO BUILDING MATERIALS AND COLOR. INSTALLATION: HIGH QUALITY INSTALLATION WITHOUT EXPOSED WIRING, RACEWAYS, OR OTHER STABLIZING DEVICES INCLUDING BACKER MOUNTS. ATTACHMENTS SHALL BE HIDDEN FROM VIEW IN LEAST DESTRUCTIVE MANNER POSSIBLE. ADDITIONAL REQUIREMENTS: SIGNS IN THIS ZONE MAY BE ATTACHED TO WINDOWS AND/OR DOORS. SIGN ZONE 3 MIN. 1'-6" MI N . 1'- 6 " SECOND FLOOR (RES. UNIT) 10'-6" GROUND FLOOR 0" SECOND FLOOR (MEZZANINE)14'-6" TOP OF TOWER ROOF 40'-0" TOP OF UPPER ROOF33'-5" TOP OF LOWER ROOF25'-5" SIGN ZONE 4 TYPES PERMITTED: WALL-MOUNTED SIGNS NUMBER: 1 SIGN MAXIMUM MAXIMUM SIZE: 150 SF TOTAL DESIGN: THREE-DIMENSIONAL LETTERING AND/OR LOGO BALANCED AND IN PROPORTION TO SCALE WITH BUILDING ELEVATION WITH COMPOSITION THAT DOES NOT OVERWHELM OR OBSCURE DESIGN. MATERIAL: HIGH QUALITY AND DURABLE MATERIALS THAT ARE COMPLEMENTARY AND/OR SIMILAR TO BUILDING MATERIALS AND DO NOT DISTRACT FROM OF OVERWHELM DESIGN OR OVERALL BUILDING FORM. SIGN MATERIALS SHALL CONVEY A SENSE OF PERMANENCE AND DURABILITY, AND NOT CONSIST OF FOAM, POSTER BOARD, FLAT PLASTIC, OR ANY OTHER MATERIAL INDICATING TEMPORARY SIGNAGE. COLOR: ALL COLORS SHOULD BE COMPLEMENTARY TO BUILDING MATERIALS AND COLOR. ILLUMINATION: EXTERNAL OR INTERNAL PERMITTED CONSISTENT W/SLO MUNI CODE SECTION 15.40.430 INSTALLATION: HIGH QUALITY INSTALLATION USING A DIRECT OR FLUSH MOUNT WITHOUT EXPOSED WIRING, RACEWAYS, OR OTHER STABLIZING DEVICES INCLUDING BACKER MOUNTS. ATTACHMENTS SHALL BE HIDDEN FROM VIEW IN LEAST DESTRUCTIVE MANNER POSSIBLE. MIN. 1'-6" MIN. 1'-6" BO T T O M O F S I G N S H A L L B E A B O V E L A N D S C A P E F E A T U R E S MI N . 2'- 0 " SECOND FLOOR (RES. UNIT)10'-6" GROUND FLOOR0" TOP OF TOWER ROOF40'-0" TOP OF UPPER ROOF 33'-5" TOP OF LOWER ROOF25'-5" WALL SIGN ZONE 5 TYPES PERMITTED: WALL-MOUNTED SIGNS NUMBER: 1 SIGN MAXIMUM MAXIMUM SIZE: 300 SF TOTAL DESIGN: THREE-DIMENSIONAL LETTERING AND/OR LOGO BALANCED AND IN PROPORTION TO SCALE WITH BUILDING ELEVATION WITH COMPOSITION THAT DOES NOT OVERWHELM OR OBSCURE DESIGN. MATERIAL: HIGH QUALITY AND DURABLE MATERIALS THAT ARE COMPLEMENTARY AND/OR SIMILAR TO BUILDING MATERIALS AND DO NOT DISTRACT FROM OF OVERWHELM DESIGN OR OVERALL BUILDING FORM. SIGN MATERIALS SHALL CONVEY A SENSE OF PERMANENCE AND DURABILITY, AND NOT CONSIST OF FOAM, POSTER BOARD, FLAT PLASTIC, OR ANY OTHER MATERIAL INDICATING TEMPORARY SIGNAGE. COLOR: ALL COLORS SHOULD BE COMPLEMENTARY TO BUILDING MATERIALS AND COLOR. ILLUMINATION: EXTERNAL OR INTERNAL PERMITTED CONSISTENT W/SLO MUNI CODE SECTION 15.40.430 INSTALLATION: HIGH QUALITY INSTALLATION USING A DIRECT OR FLUSH MOUNT WITHOUT EXPOSED WIRING, RACEWAYS, OR OTHER STABLIZING DEVICES INCLUDING BACKER MOUNTS. ATTACHMENTS SHALL BE HIDDEN FROM VIEW IN LEAST DESTRUCTIVE MANNER POSSIBLE. MIN. 2'-10 1/4" SECOND FLOOR (RES. UNIT) 10'-6" WALL MOUNTED SIGN NOTE: THE SIGNS ABOVE ARE EXAMPLES OF SIGNAGE THAT GENERALLY COMPLY WITH THE DESIGN STANDARDS OF THIS SIGNAGE PROGRAM. SEE EACH ZONE FOR SPECIFIC REQUIREMENTS. WINDOW SIGNAWNING SIGN PROJECTING SIGN HANGING & SUSPENDED SIGN THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 539 Marsh Street San Luis Obispo, CA 805.541.1010 info@tenoverstudio.com www.tenoverstudio.com NO T F O R C O N S T R U C T I O N DRWN BY: CHK'D BY: PROJ #: NOT FOR CONSTRUCTION JOEL R. SNYDER C-39262 2.28.2023RENEWAL L I CE N S E D A R CHI T E C T S T A T E OF A L I F O RNI A C MF NM SIGNAGE PROGRAM 10 H I G U E R A 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 2023-020 A3.1 1/8" = 1'-0"2 EAST ELEVATION 1/8" = 1'-0"1 SOUTH ELEVATION 1/8" = 1'-0"3 WEST ELEVATION 3" = 1'-0"4 SIGNAGE TYPE EXAMPLES NO.DATE SUBMITTAL 1 23.07.14 ARC INITIAL SUBMITTAL 2 24.02.06 ARC RESUBMITTAL 1 3 24.03.19 ARC RESUBMITTAL 2 4 24.61.18 PLANNING HEARING Page 97 of 98 THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF TEN OVER STUDIO, INC. THE DESIGN AND INFORMATION REPRESENTED ON THESE DRAWINGS ARE EXCLUSIVELY FOR THE PROJECT INDICATED AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM TEN OVER STUDIO, INC. COPYRIGHT 2022 539 Marsh Street San Luis Obispo, CA 805.541.1010 info@tenoverstudio.com www.tenoverstudio.com NO T F O R C O N S T R U C T I O N DRWN BY: CHK'D BY: PROJ #: NOT FOR CONSTRUCTION JOEL R. SNYDER C-39262 2.28.2023 RENEWAL L I C E N S E D A RCH I T E C T S T A T E O F A L I F O R NI A C EH NM PERSPECTIVE IMAGES 10 H I G U E R A 10 H I G U E R A S T . SA N L U I S O B I S P O , C A 2023-020 01 -VIEW FROM ENTRY 02 -VIEW FROM PLAZA 03 -VIEW FROM PARKING AREA 04 -VIEW FROM LOADING AREA A4.0 NO. DATE SUBMITTAL 1 23.07.14 ARC INITIAL SUBMITTAL 24.02.06 ARC RESUBMITTAL 12 3 24.03.19 ARC RESUBMITTAL 2 4 24.61.18 PLANNING HEARING Page 98 of 98 1 REVIEW OF A NEW MIXED-USE PROJECT THAT CONTAINS APPROXIMATELY 23,164 SQUARE FEET OF COMMERCIAL SPACE AND A ONE BEDROOM RESIDENTIAL UNIT,WITH ASSOCIATED SITE IMPROVEMENTS,A SIGN PROGRAM,AND A REQUEST TO REMOVE TWO TREES AND REPLANT 25 TREES Applicant: Keith Sweeny ARCH-0358-2023 (10 Higuera Street) New Mixed-Use Project June 26, 2024 2 Recommendation Adopt the Draft Resolution approving the proposed new mixed-use project, associated site design and improvements, sign program, and the removal of two trees based on findings and subject to conditions of approval. 3 Planning Commission’s Purview The Planning Commission’s role is to review the project for consistency with the General Plan, Zoning Regulations, Community Design Guidelines (CDG), Sign Regulations and applicable City Standards. Per Zoning Regulations section 17.106.030(D)(3) a nonresidential / mixed-use development with more than ten thousand gross square feet of new construction requires discretionary Planning Commission review. 4 Project Location Location: 10 Higuera Street General Plan Land Use Designation: General Retail and Services & Manufacturing Zoning Designation: Service Commercial zone with a special consideration overlay (C-S-S) & Tourist Commercial zone with a mixed-use overlay (C-T-MU) 5 Project Description The proposed project includes: A new mixed-use building with 23,164 square feet of commercial space and a one- bedroom residential unit, Associated site improvements, A sign program, and A request to remove two trees. 6 Project Design Architecture: Contemporary / Industrial Design details: The building utilizes symmetrical and asymmetrical lines, large windows, and a mix of materials and colors that contribute to the contemporary design. 7 Project Elevations East Elevation West Elevation 8 Project Elevations South Elevation North Elevation 9 Project Design Materials: Vertical box rib metal siding, vertical wood siding, concrete bulkheads, dark bronze aluminum storefront windows, and a standing seam metal roof. Colors: Black, Gray, natural wood, and dark bronze colors are proposed. 10 Project Landscape and Site Plan Includes: •Removal of 2 Peruvian pepper trees •Replanting of numerous groundcovers, shrubs and 25 trees including: •12 strawberry trees •8 buckeye trees •5 red oak trees 11 Sign Program Sign programs are required for new mixed-use projects (M.C. §15.40.485). The applicant has proposed a sign program with 5 sign areas or zones. There would be a maximum of 4 signs as well as signage on the entry way windows / doors. 12 Project Analysis •The project is not seeking any exceptions from development standards and complies with relevant development standards of the Zoning Regulations. •As outlined in the staff report, the project was evaluated for and determined to be consistent with the City’s General Plan and Zoning Regulations. 13 Previous Review •May 6, 2024: ARC reviewed the proposed mixed-use project and found the proposed project design consistent with the Community Design Guidelines, Sign Regulations, and applicable City Standards with specific direction regarding design changes and recommended the Planning Commission approve the design. •May 20, 2024: Tree Committee reviewed the removal of two Peruvian pepper (Schinus molle) trees and the replanting of 25 new trees as a part of the proposed new mixed-use project. The Tree Committee recommended the Planning Commission approve the Tree Removal Application with specific direction regarding trees species selection. 14 ARC Direction Item #1 Provide a change in color, materials, and/or window fenestration to the north elevation to provide architectural interest. •Per direction from the ARC, the applicant has revised the north elevation to include more architectural interest by adding window fenestration and wrapping the wood accent feature from the west elevation around to the north elevation. •The Planning Commission should discuss if the proposed revisions provide sufficient articulation and architectural features to break up the large wall expanse on the north elevation. 15 Project Elevations Revised North Elevation Original North Elevation New windows Wood accent feature 16 ARC Direction Item #1 Provide screening around the bicycle lockers and/or paint them so that they better integrate into the site plan and overall architectural design. •The applicant has indicated that they are willing to better integrate the long- term bicycle lockers into the site plan and design. •Condition of approval #11 that states “Building plans submitted for the project shall show that the bicycle lockers are screened and/or painted so that they become integrated into the site and overall architectural design to the satisfaction of the Community Development Director.” 17 Tree Committee Direction Item #1 The applicant should consider replacing the proposed twelve (12) Marina Strawberry trees (Arbutus) with an alternate species from the City's Master Tree List, with the goal of maximizing canopy potential. •The Committee noted that Strawberry trees are not well suited for high traffic areas, as their leaf and fruit litter are messy and require constant cleanup / maintenance and, even at maturity, this species will not provide sufficient canopy coverage. •Condition of approval #14(a) that states that “Arbutus x ‘marina’ shall not be planted as part of the landscape plan. The project shall select another species from the City’s Master Tree List to be planted instead, to the satisfaction of the City Arborist.” 18 Recommendation Adopt the Draft Resolution approving the proposed new mixed-use project, associated site design and improvements, sign program, and the removal of two trees based on findings and subject to conditions of approval.