Loading...
HomeMy WebLinkAboutPRR24191 Rourke 163 Serrano Heights December 22, 2023 Plan Check Review # 1 Staff Response: Review #1 Review #2 Review #3 Review #4 (Additional Fees) Applicant Response: Please indicate here if any new changes have been made to the plans that are not a result of the corrections from this list. Briefly describe the type of changes and their location on the plans. Check one: _____yes ______no Print Name: If yes, please briefly describe the changes and where they are located on the plans: Project Address 163 Serrano Heights Unit A Project Name Rev Plan to add retaing wall and fence Application Number PLREV-0587-2023 (BLDG-2017-2021 & GRAD-1857-2022) Review of new Single Family Residence Occupancy Class Click or tap here to enter text. Construction Type Click or tap here to enter text. Occupant Load Click or tap here to enter text. Sprinklers Click or tap here to enter text. 1 2 3 4 Plan Check Review #1 163 Serrano Heights Unit A PLREV-0587-2023 (BLDG-2017-2021 & GRAD-1857-2022) Page 2 Engineering Development Review Bridget Fraser bfraser@slocity.org 805-781-7192 ☐ Ready for Action ☒ Needs Resubmit ☐ OK for Counter Re-Check ☒ Final Inspection Required (staff reminder: add yourself to final inspection in permit module) General Comments: 1. Provide responses to each comment, as appropriate, and note on what page(s) in the plan set each item is addressed. Include the name and phone # of the person(s) providing responses. 2. Please clarify drainage strategy now that the new wall appears to block upslope drainage. Looks like drainage will hit back of wall and drain toward and pond in the lower corner. 3. Provide a cross-section of the wall and footings with dimension to PL. Verify wall and footing does not cross property line. Provide construction details for the retaining wall and fence. 1 From:Buckley, Nick Sent:Tuesday, April 11, 2023 4:16 PM To:Nelson, Trevor Subject:RE: 163 Serrano Heights Dr A Perfect, thank you. Nick Buckley Code Enforcement Officer Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 E nbuckley@slocity.org T 805.783.7872 slocity.org Stay connected with the City by signing up for e-notifications From: Nelson, Trevor <tnelson@slocity.org> Sent: Tuesday, April 11, 2023 2:58 PM To: Buckley, Nick <nbuckley@slocity.org> Subject: FW: 163 Serrano Heights Dr A Setting up a time to meet the owner/builder John Rourke on site Tuesday 4/18. He will be emailing me some photos of what he believes might be the retaining wall in question before then which I will forward along. Thank you, Trevor Nelson Supervising Building Inspector Community Development Building and Safety 919 Palm Street, San Luis Obispo, CA 93401-3218 E tnelson@slocity.org T 805.781.7153 slocity.org Stay connected with the City by signing up for e-notifications 2 From: Nelson, Trevor Sent: Tuesday, April 11, 2023 2:42 PM To: John Rourke < Subject: 163 Serrano Heights Dr A John, Are you still active on this project? 163 Serrano Heights Dr A BLDG-2017-2021 Some questions were brought up to me about misc site work, but I don’t show any inspections since 9/02/22. Can you give me a call when you get a chance? Thank you, Trevor Nelson Supervising Building Inspector Community Development 919 Palm St, San Luis Obispo, CA 93401-3218 E tnelson@slocity.org T 805.781.7153 C 805.431.7160 slocity.org Stay connected with the City by signing up for e-notifications S13°41'28"E 144.61'S0°01'06"E 140.46'N0°00'53"E 100.87'S3°02'24"E 101.03'N89°56'08"W 200.35'S0°01'06"E 85.42'S89°56'08"E 121.00'S89°56'08"E 179.22' W W W W W W W W W W SSSSSSSSSSSSSSSSSSSSS89°56'08"E 86.82' N82°31'28" W 1 1 9 . 8 8 ' S89°56'20"E 94.62' N89°56'08"W 100.00'N0°00'53"E 125.00'W W W W W W W W SSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSS400 39 5 405410415 420 SERRANO LANE(E) OVERHEAD ELECTRICAL (E) 6" SEWER LATERAL (E) 8" WATER MAIN (E) GAS MAIN (E) FENCE TO REMAIN (E) POWER POLE (N) PROPOSED DRIVEWAY (N) AC PAVEMENT TO WIDEN ROAD (N) FIRE HYDRANT LATERAL HYDRANT SHOWN FOR COORDINATION ONLY (E) RESIDENCE TO REMAIN (E) DRIVEWAY TO REMAIN (E) WATER SERVICE (N) WATER SERVICE LATERALS METER BOXES SHOWN FOR COORDINATION ONLY (E) 60.00' ACCESS EASEMENT PER 605-OR-244 (E) 10.00' WIDE ACCESS EASEMENT (E) 5.00' WIDE SEWER EASEMENT 20.00' 12.00'20.00' PRIVATE ACCESS, PRIVATE UTILITYAND DRAINAGE EASEMENTSHARED ACCESS DRIVEWAY (E) SEWER LATERAL FOR (E) RESIDENCE(E) SEWER LATERAL FOR (E) RESIDENCE (N) AC PAVEMENT TO WIDEN ROAD12.00' PRIVATE ACCESS, PRIVATE UTILITYAND DRAINAGE EASEMENT20.00' PRIVATE DRAINAGE EASEMENT (E) 10.00' UTILITY EASEMENT (E) CENTERLINE OF POWER POLE EASEMENT 10.00' MIN.12.00'(N) 4'-0" MAX RETAINING WALL WITH FENCE 1 TITLE SHEETDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:58amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C001-NS.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC0.1 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23SHEET INDEX: C0.1 TITLE SHEET C0.2 NOTE SHEET C0.3 CONDITIONS OF APPROVAL & MITIGATIONS C0.4 CONDITIONS OF APPROVAL & MITIGATIONS C1.1 GRADING, DRAINAGE, & UTILITY PLAN C1.2 FIRE ACCESS C1.3 DETAIL SHEET C2.1 EROSION CONTROL PLAN C2.2 EROSION CONTROL DETAILS PROJECT INFORMATION: 163 SERRANO HEIGHTS DR SAN LUIS OBISPO, CA 93405 APN#:052-061-034 EXISTING LOT SIZE:1.56 ACRES PROPOSED LOTS:SEE PLAN ZONING:R-1 PROJECT TEAM: OWNERS INFORMATION JOHN ROURKE 163 SERRANO HEIGHTS DR. SAN LUIS OBISPO, CA 93405 805.440.4973 PROJECT CIVIL ENGINEER & AGENT ABOVE GRADE ENGINEERING 245 HIGUERA STREET SAN LUIS OBISPO, CA 93401 805.540.1515 PREPARED BY: SCOTT STOKES, PRESIDENT, PE 58256 ABOVE GRADE ENGINEERING 245 HIGUERA STREET SAN LUIS OBISPO, CA 93401 VICINITY MAP: SAN LUIS OBISPO LEGEND: (E) ASPHALT TO REMAIN (N) ASPHALT CONCRETE (AC) PAVEMENT ( IN FEET ) 1 INCH = FT. 10 2020 20 400 SITE PLAN SCALE: 1" = 20' SCOPE OF WORK: THE SCOPE OF WORK FOR THIS PROJECT INCLUDES THE GRADING ACTIVITIES NECESSARY TO COMPLETE THE WIDENING OF SERRANO HEIGHTS, A NEW ASPHALT PAVEMENT ACCESS DRIVEWAY TO PROVIDE FIRE ACCESS, A NEW PRIVATE DRIVEWAY FOR THE EXISTING RESIDENCE, TRENCHING FOR UTILITY STUBS, AND 170 LINEAR FEET OF RETAINING WALL. COORDINATION ONLY FEATURES: UTILITY FEATURES SUCH AS THE FIRE HYDRANT AND WATER METER BOXES ARE SHOWN FOR COORDINATION ONLY. THE FIRST BUILDING PERMIT SUBMITTED FOR ONE OF THE THREE UNDEVELOPED LOTS SHALL BE CONDITIONED TO INSTALL THE FIRE HYDRANT AND WATER METER BOXES. GRIND ASPHALT 1 1 NOTE SHEETSTANDARD GRADING AND DRAINAGE NOTES: 1.ALL GRADING AND CONSTRUCTION SHALL CONFORM TO THE RECOMMENDATIONS IN THE GEOTECHNICAL INVESTIGATION REPORT PREPARED FOR THIS PROJECT, THE CITY OF SAN LUIS OBISPO STANDARD SPECIFICATIONS, LATEST EDITION, AND TO THE SATISFACTION OF THE SOILS ENGINEER. 2.THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE INDUSTRIAL SAFETY REGULATIONS. THE OWNER AND ITS OFFICIALS, THE ENGINEER, AND THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ENFORCING SAFETY REGULATIONS. 3.THE PAVING STRUCTURAL SECTION SHALL BE BASED ON THE SOILS TESTS PERFORMED AT THE TIME OF CONSTRUCTION AND A T.I. OF 8.5. R-VALUE TO BE DETERMINED AT TIME OF CONSTRUCTION BY SOILS ENGINEER. 4.ALL CONTACT SURFACES BETWEEN ORIGINAL GROUND AND RECOMPACTED FILL MATERIAL SHALL BE EITHER HORIZONTAL OR VERTICAL (PER SECTION 19 CALTRANS STANDARD SPECIFICATIONS DATED JULY 2010). 5.FILL MATERIAL SHALL BE SPREAD IN LIFTS AS REQUIRED BY THE GEOTECHNICAL INVESTIGATION REPORT AND THE CITY OF SAN LUIS OBISPO STANDARD SPECIFICATIONS. FILL OPERATIONS SHALL BE OBSERVED BY THE SOILS ENGINEER. THE MATERIALS FOR ENGINEERED FILL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER. ANY IMPORTED MATERIALS MUST BE APPROVED BEFORE BEING BROUGHT TO THE SITE. THE MATERIALS USED SHALL BE FREE OF ORGANIC MATTER AND OTHER DELETERIOUS MATERIALS. 6.OVER EXCAVATION, REPLACEMENT AND COMPACTION REQUIREMENTS SHALL CONFORM TO THE GEOTECHNICAL INVESTIGATION REPORT AND THE CITY OF SAN LUIS OBISPO SPECIFICATIONS. 7.FIELD DENSITY TESTS SHALL BE MADE UNDER THE DIRECTION OF THE GEOTECHNICAL ENGINEER ON EACH COMPACTED LAYER. AT LEAST ONE (1) TEST SHALL BE MADE FOR EACH FIVE-HUNDRED (500) CUBIC YARDS, OR A FRACTION THEREOF, PLACED WITH A MINIMUM OF TWO (2) TESTS PER LAYER IN ISOLATED AREAS OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. 8.UPON COMPLETION OF THE GRADING OPERATION, THE GEOTECHNICAL ENGINEER SHALL CERTIFY THAT ALL GRADING COMPLIES WITH THE RECOMMENDATIONS OF THE SPECIFICATIONS AND THE REFERENCED GEOTECHNICAL INVESTIGATION REPORT. 9.EXPORT MATERIAL (IF ANY) SHALL BE DISPOSED OF IN AN ACCEPTABLE LOCATION. 10.THE OWNER OR THE ENGINEER OF RECORD SHALL REQUIRE EROSION CONTROL DEVICE INSTALLATION WITHIN ANY DOWNSTREAM DRAINAGE FACILITY, UPON APPROVAL BY THE CITY OF SAN LUIS OBISPO. 11.A STANDBY CREW FOR EMERGENCY WORK SHALL BE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. NECESSARY MATERIALS SHALL BE AVAILABLE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS IMMINENT. 12.ALL PROTECTIVE DEVICES DIRECTED TO BE INSTALLED BY THE CONTRACTOR SHALL BE IN PLACE AT THE END OF EACH WORK DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY EXCEEDS 40%. 13.POSITIVE DRAINAGE SHALL BE PROVIDED AWAY FROM ALL MANMADE SLOPES. NO RUNOFF MAY BE CONCENTRATED. CONCENTRATED DRAINAGE IS NOT ALLOWED ACROSS PUBLIC SIDEWALKS. 14.PERMANENT DUST CONTROL MEASURES SHALL BE IMPLEMENTED AS SOON AS POSSIBLE FOLLOWING COMPLETION OF ANY SOIL DISTURBING ACTIVITIES PER OWNERS LANDSCAPE NEEDS. OWNER TO HYDROSEED DISTURBED GROUND AS SOON AS PRACTICAL AFTER CONSTRUCTION IS COMPLETE. 15.EXPOSED GROUND AREAS THAT ARE PLANNED TO BE REWORKED AT DATES MORE THAN THREE (3) WEEKS AFTER INITIAL GRADING SHALL BE SOWN WITH A FAST GERMINATING NATIVE GRASS SEED AND WATERED UNTIL VEGETATION IS ESTABLISHED. 16.AN EROSION CONTROL PLAN IS REQUIRED AT ALL TIMES DURING CONSTRUCTION. 17.CUT OR FILL SLOPES SHALL BE NO STEEPER THAN TWO (2) HORIZONTAL TO ONE (1) VERTICAL (2:1) WITHOUT JUSTIFICATION FROM THE GEOTECHNICAL ENGINEER. 18.ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE VERTICAL (4:1) AND GREATER SHALL BE PREPARED AND MAINTAINED TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED NO LATER THAN THIRTY (30) DAYS PRIOR TO REQUEST FOR FINAL APPROVAL. 19.DUST CONTROL IS TO BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. 20.ALL DISTURBED AREA SHALL BE HYDRO-SEEDED OR PLANTED WITH APPROVED EROSION CONTROL VEGETATION AS SOON AS PRACTICAL AFTER CONSTRUCTION IS COMPLETE. 21.ALL GRADING SHALL CONFORM TO THE CURRENT EDITION OF THE CBC. 22.MINIMUM SETBACK TO CREEKS AND BLUFFS SHALL BE MAINTAINED. MINIMUM SETBACK OF TWO FEET FROM ALL PROPERTY LINES WILL BE MAINTAINED FOR ALL GRADING. 23.MINIMUM SLOPE AWAY FROM BUILDINGS SHALL BE 5% FOR THE FIRST 5 FEET AROUND PERIMETER IN LANDSCAPED AREAS. 24.UNLESS NOTED OTHERWISE, CONTRACTOR TO PROTECT ALL TREES IN PLACE. 25.THE CONTRACTOR SHALL BE RESPONSIBLE FOR GRADING AROUND INLETS AND OUTLETS OF STORM DRAIN PIPES TO THE SATISFACTION OF THE CITY ENGINEER. 26.ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT LESS THAN 2% SHALL HAVE FINAL GRADIENTS CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER PRIOR TO FINAL INSPECTION APPROVALS. 27.CONTACT THE CITY ARBORIST AT 781-7023 TO REVIEW THE PROPOSED TREE PROTECTION MEASURES PRIOR TO COMMENCING WITH ANY DEMOLITION, GRADING, EXCAVATION, OR CONSTRUCTION. ANY SAFETY PRUNING OR THE CUTTING OF SUBSTANTIAL ROOTS SHALL BE APPROVED BY THE CITY AND COMPLETED BY A CITY-APPROVED ARBORIST. CONTACT THE CITY ARBORIST AT LEAST 48 HOURS PRIOR TO CONSTRUCTION IN AREAS WHERE TREE PROTECTION AND INSPECTION IS REQUIRED. 28.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER AND FIRE SERVICE LATERALS, CURB GUTTER AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. 29.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. 30.NO CONSTRUCTION SHALL BE STARTED WITHOUT PLANS APPROVED BY THE DEPARTMENT OF PUBLIC WORKS. THE DEPARTMENT OF PUBLIC WORKS SHALL BE NOTIFIED AT LEAST 48 HOURS PRIOR TO STARTING OF CONSTRUCTION AND OF THE TIME & LOCATION OF THE PRECONSTRUCTION CONFERENCE. ANY CONSTRUCTION DONE WITHOUT APPROVED PLANS OR PRIOR NOTIFICATION TO THE DEPARTMENT OF PUBLIC WORKS WILL BE REJECTED AND WILL BE AT THE CONTRACTORS AND/OR OWNER'S RISK. 31.ALL CONSTRUCTION WORK AND INSTALLATIONS SHALL CONFORM TO THE LATEST CITY STANDARDS AND SPECIFICATIONS AND ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE DEPARTMENT OF PUBLIC WORKS. THE CURRENT ADOPTED STANDARDS ARE DATED MAY 2018. 32.A PRE-CONSTRUCTION MEETING SHALL BE COORDINATED BY THE OWNER/DEVELOPER OR CONTRACTOR AND SHALL INCLUDE PERTINENT CITY STAFF. AS A MINIMUM, THE ASSIGNED BUILDING INSPECTOR AND PUBLIC WORKS INSPECTOR SHALL BE INCLUDED IN THIS MEETING TO DISCUSS THE LIMIT OF SUBDIVISION IMPROVEMENTS AND INSPECTION RESPONSIBILITIES. 33.THE PUBLIC IMPROVEMENTS SHALL BE SUBSTANTIALLY COMPLETE TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR PRIOR TO FINAL INSPECTION APPROVALS AND/OR OCCUPANCY OF ANY BUILDING. 34.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST 48 HOURS NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. 35.ANY SECTION OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 36.THE ELEVATION AND COMPONENT SIZING OF THE DRAINAGE SYSTEM INCLUDING BUT LIMITED TO DETENTION BASINS, PARKING LOT DETENTION CURB ELEVATIONS, DRAINAGE PIPING, INLETS, WEIR ELEVATIONS, AND ORIFICES SHALL BE CERTIFIED BY A LICENSED ENGINEER OR SURVEYOR. 37.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. THE CURRENT ADOPTED STANDARDS ARE DATED MAY 2018. 38.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECT IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. 39.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. 40.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. 41.HAND DIGGING IS REQUIRED WITHIN THE DRIP LINE OF TREES TO REMAIN; ANY EXPOSED ROOTS SHALL BE OBSERVED BY CITY ARBORIST BEFORE REMOVING. CONTACT CITY ARBORIST RON COMBS AT 781-7023 BEFORE COMMENCING WITH CONSTRUCTION, GRADING OR EXCAVATIONS. 42.ONE 15-GALLON STREET TREE IS REQUIRED FOR EACH 35 LINEAL FEET OF FRONTAGE OR FRACTION THEREOF. TREE SPECIES AND PLANTING REQUIREMENTS SHALL BE PER CITY ENGINEERING STANDARDS. APPROXIMATE EARTHWORK INFORMATION: CUT 60 CY FILL 10 CY NET 70 CY MAX DEPTH OF CUT 1.5 FT MAX DEPTH OF FILL 0.5 FT AREA OF DISTURBANCE 0.07 AC NOTE:THE EARTHWORK QUANTITIES SHOWN ARE FOR BONDING AND ESTIMATING PURPOSES ONLY AND ARE CALCULATED FROM APPROXIMATE SUBGRADE TO EXISTING SURFACE. THE QUANTITIES DO NOT TAKE CERTAIN FACTORS INTO ACCOUNT, INCLUDING, BUT NOT LIMITED TO SUBGRADE, AREA OF OVEREXCAVATION AND RECOMPACTION, SHRINKAGE AND EXPANSION OF THE SOIL. THE CONTRACTOR IS RESPONSIBLE FOR CALCULATING EARTHWORK QUANTITIES FOR BIDDING AND CONSTRUCTION PURPOSES. SURVEY INFORMATION: TOPOGRAPHIC SURVEY PERFORMED MARCH, 2018 BY MBS LAND SURVEYS BASIS OF BEARINGS:THE BASIS OF BEARINGS FOR THIS SURVEY IS A GEODETIC NORTH BASED ON A GPS OBESERVATION FROM A 90d SET IN A DIRT FIELD DISTANT S 22° 12' 12" E 138.25 FEET FROM THE FOUND 1" IRON PIPE AT THE SOUTHEAST CORNER OF D3. SUPPLEMENTAL SURVEY PERFORMED DECEMBER, 2018 BY ABOVE GRADE ENGINEERING, INC BOUNDARY:THE EXTERIOR BOUNDARY SHOWN IS PER RECORD OF SURVEY 17-043. ENGINEERED GRADING OBSERVATION AND TESTING PROGRAM THE SOILS ENGINEER OF RECORD SHALL BE RETAINED PRIOR TO THE START OF CONSTRUCTION TO PERFORM THE FOLLOWING VERIFICATION AND INSPECTION TASKS DURING CONSTRUCTION: VERIFICATION AND INSPECTION TASK CONTINUOUS DURING TASK LISTED PERIODICALLY DURING TASK LISTED 1. VERIFY MATERIALS BELOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. X 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. X 3. PERFORM CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIAL.X 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF CONTROLLED FILL. X 5. PRIOR TO PLACEMENT OF CONTROLLED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PERPARED PROPERLY.X A FINAL REPORT DISCUSSING THE FOLLOWING WILL BE REQUIRED FOR COUNTY FINAL APPROVAL: - COMPACTION REPORTS - VERIFICATION OF SLOPES - VERIFICATION OF BOTTOM PREPERATION FOR KEYS AND BENCHING OF FILL SOILS ENGINEER INFORMATION: THE SOILS ENGINEER FOR THIS PROJECT IS" GEOSOLTIONS, INC. 220 HIGH STREET SAN LUIS OBISPO, CA 93401 805.543.8539 THE SOILS REPORT FOR THIS PROJECT IS DATED NOVEMBER, 2018, PROJECT NO. SL10935-1 NOTE:A PAD CERTIFICATION FOR THIS PROJECT WILL BE REQUIRED. A SOILS OR CIVIL ENGINEER IS TO DETERMINE GRADING PERFORMED IS IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED PLANS AND IS SUITABLE TO SUPPORT THE INTENDED STRUCTURE. A SOILS ENGINEER WILL NEED TO BE ON-SITE TO OBSERVE CERTAIN CONSTRUCTION ACTIVITIES. STORMWATER INFORMATION: ·REFER TO PROVIDED SWCP REPORT DATED 11-29-2021. CITY BENCH MARK: THE BENCH MARK FOR THIS PROJECT IS A FOUND CITY OF SAN LUIS OBISPO BENCH MARK NUMBER 166A. BEING A LEAD AND TACK IN TOP OF CURB AT THE BCR OF THE NORTHEASTERLY CURB OF PALOMAR AND SERRANO ELEVATION = 274.26' NAVD 88 DESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:58amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C001-NS.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC0.2 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23DIAL TOLL FREE AT LEAST TWO DAYS BEFORE YOU DIG 811 UNDERGROUND SERVICE ALERT (USA) EROSION CONTROL NOTES: 1.DURING CONSTRUCTION, THE CONTRACTOR MUST DIRECT ALL RUNOFF TO NON-ERODIBLE LOCATIONS. 2.A STANDBY CREW FOR EMERGENCY WORK SHALL BE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 15 THROUGH APRIL 15). NECESSARY MATERIALS SHALL BE AVAILABLE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS IMMINENT. 3.THE CONTRACTOR SHALL CONSTRUCT TEMPORARY EROSION CONTROL MEASURES AS SHOWN ON THIS PLAN AND/OR AS DIRECTED BY THE ENGINEER TO CONTROL DRAINAGE WHICH HAS BEEN AFFECTED BY GRADING AND/OR TRENCHING OPERATIONS. 4.A RESPONSIBLE PERSON IS TO BE NAMED HEREIN ________________________ AND PHONE NUMBER _________________ WHO WILL BE ON CALL IN THE EVENT IT IS NECESSARY TO IMPLEMENT EROSION CONTROL MEASURES OR IN THE EVENT OF AN EMERGENCY. 5.ALL PROTECTIVE DEVICES TO BE INSTALLED SHALL BE IN PLACE AT THE END OF EACH WORK DAY WHEN THE FIVE-DAY RAIN PROBABILITY EXCEEDS 40 PERCENT. 6.AFTER A RAINSTORM, ALL SILT AND DEBRIS SHALL BE REMOVED FROM CHECK BERMS AND SEDIMENTATION BASIN AND THE BASIN PUMPED DRY. 7.THE ENGINEER OF RECORD, OR HIS AUTHORIZED REPRESENTATIVE MAY REQUIRE THE DEVELOPER AT ANY TIME TO INSTALL AND/OR CONSTRUCT ADDITIONAL DRAINAGE STRUCTURES AS NECESSARY TO PREVENT OR CONTROL EROSION. 8.THE EROSION CONTROL DEVICES ON THIS PLAN ARE A GENERAL CONCEPT OF WHAT MAY BE REQUIRED. EROSION CONTROL DEVICES MAY BE RELOCATED, DELETED OR ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING ON THE ACTUAL SOIL CONDITIONS ENCOUNTERED. EROSION CONTROL DEVICES MAY BE PLACED AT THE DISCRETION OF THE ENGINEER OR THE BUILDING INSPECTOR. 9.THE CONTRACTOR IS RESPONSIBLE TO KEEP IN FORCE ALL EROSION CONTROL DEVICES AND TO MODIFY THOSE DEVICES AS SITE PROGRESS DICTATES. 10.THE CONTRACTOR SHALL MONITOR THE EROSION CONTROL DEVICES DURING STORMS AND MODIFY THEM IN ORDER TO PREVENT PROGRESS OF ANY ONGOING EROSION. 11.THE CONTRACTOR IS RESPONSIBLE FOR CLEANING ANY EROSION OR DEBRIS SPILLING ONTO A PUBLIC STREET. 12.THE CONTRACTOR SHALL CONTACT THE ENGINEER IN THE EVENT THAT THE EROSION CONTROL PLAN AS DESIGNED REQUIRES ANY SUBSTANTIAL REVISIONS. 13.NO CUT OR FILL SLOPES SHALL BE STEEPER THAN 2' HORIZONTAL TO 1' VERTICAL. 14.ALL STRAW WATTLES TO BE INSTALLED AS INDICATED PER MANUFACTURER'S RECOMMENDATIONS. 15.SILT FENCE SHALL BE INSTALLED AS INDICATED PER MANUFACTURER'S RECOMMENDATIONS. 16.SPECIFIC EROSION CONTROL NOTES REFER TO THE CALIFORNIA STORMWATER BMP HANDBOOK AND CALTRANS STANDARD SPECIFICATIONS. THE CONTRACTOR IS RESPONSIBLE TO INSTALL AND MAINTAIN ADEQUATE EROSION CONTROL DEVICES AT ALL TIMES PER THE RECOMMENDATIONS SET FORTH IN SAID REFERENCES. 17.TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN PERMANENT IMPROVEMENTS, PLANTINGS, AND FACILITIES ARE IN PLACE. TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION APPROVALS. ADDITIONAL NOTES: 1.THE SOILS REPORT, NUMBER SL10935.1 PREPARED BY GEOSOLUTIONS, INC DATED NOVEMBER 20, 2018 IS PART OF THESE PLANS AND ALL RECOMMENDATIONS THERE IN SHALL BE COMPLIED WITH. 2.THE PROJECT SHALL COMPLY WITH THE CALIFORNIA PLUMBING CODE (CPC). REQUIRED ENVIRONMENTAL MITIGATION MEASURES: AIR QUALITY AQ-1 IDLING CONTROL TECHNIQUES. DURING ALL CONSTRUCTION ACTIVITIES AND USE OF DIESEL VEHICLES, THE APPLICANT SHALL IMPLEMENT THE FOLLOWING IDLING CONTROL TECHNIQUES: 1.IDLING RESTRICTIONS NEAR SENSITIVE RECEPTORS FOR BOTH ON- AND OFF-ROAD EQUIPMENT. a.STAGING AND QUEUING AREAS SHALL NOT BE LOCATED WITHIN 1,000 FEET OF SENSITIVE RECEPTORS IF FEASIBLE; b.DIESEL IDLING WITHIN 1,000 FEET OF SENSITIVE RECEPTORS SHALL NOT BE PERMITTED; c.USE OF ALTERNATIVE FUELED EQUIPMENT SHALL BE USED WHENEVER POSSIBLE; AND d.SIGNS THAT SPECIFY THE NO IDLING REQUIREMENTS SHALL BE POSTED AND ENFORCED AT THE CONSTRUCTION SITE. 2.CALIFORNIA DIESEL IDLING REGULATIONS. ON-ROAD DIESEL VEHICLES SHALL COMPLY WITH 13 CCR 2485. THIS REGULATION LIMITS IDLING FROM DIESEL-FUELED COMMERCIAL MOTOR VEHICLES WITH GROSS VEHICULAR WEIGHT RATINGS OF MORE THAN 10,000 POUNDS AND LICENSED FOR OPERATION ON HIGHWAYS. IT APPLIES TO CALIFORNIA AND NON- CALIFORNIA BASED VEHICLES. IN GENERAL, THE REGULATION SPECIFIES THAT DRIVERS OF SAID VEHICLES: a.SHALL NOT IDLE THE VEHICLE'S PRIMARY DIESEL ENGINE FOR GREATER THAN 5 MINUTES AT ANY LOCATION, EXCEPT AS NOTED IN SUBSECTION (D) OF THE REGULATION; AND b.SHALL NOT OPERATE A DIESEL-FUELED AUXILIARY POWER SYSTEM (APS) TO POWER A HEATER, AIR CONDITIONER, OR ANY ANCILLARY EQUIPMENT ON THAT VEHICLE DURING SLEEPING OR RESTING IN A SLEEPER BERTH FOR GREATER THAN 5 MINUTES AT ANY LOCATION WHEN WITHIN 1,000 FEET OF A RESTRICTED AREA, EXCEPT AS NOTED IN SUBSECTION (D) OF THE REGULATION. SIGNS MUST BE POSTED IN THE DESIGNATED QUEUING AREAS AND JOB SITES TO REMIND DRIVERS OF THE 5-MINUTE IDLING LIMIT. THE SPECIFIC REQUIREMENTS AND EXCEPTIONS IN THE REGULATION CAN BE REVIEWED AT THE FOLLOWING WEBSITE: WWW.ARB.CA.GOV/MSPROG/TRUCK- IDLING/2485.PDF. AQ-2 PARTICULATE MATTER CONTROL MEASURES. DURING ALL CONSTRUCTION AND GROUND-DISTURBING ACTIVITIES, THE APPLICANT SHALL IMPLEMENT THE FOLLOWING PARTICULATE MATTER CONTROL MEASURES AND DETAIL EACH MEASURE ON THE PROJECT GRADING AND BUILDING PLANS: 1.REDUCE THE AMOUNT OF DISTURBED AREA WHERE POSSIBLE. 2.USE OF WATER TRUCKS OR SPRINKLER SYSTEMS IN SUFFICIENT QUANTITIES TO PREVENT AIRBORNE DUST FROM LEAVING THE SITE AND FROM EXCEEDING THE SLOAPCD'S LIMIT OF 20% OPACITY FOR GREATER THAN 3 MINUTES IN ANY 60-MINUTE PERIOD. INCREASED WATERING FREQUENCY WOULD BE REQUIRED WHENEVER WIND SPEEDS EXCEED 15 MILES PER HOUR (MPH). RECLAIMED (NON-POTABLE) WATER SHOULD BE USED WHENEVER POSSIBLE. 3.ALL DIRT STOCKPILE AREAS (IF ANY) SHALL BE SPRAYED DAILY AND COVERED WITH TARPS OR OTHER DUST BARRIERS AS NEEDED. 4.PERMANENT DUST CONTROL MEASURES IDENTIFIED IN THE APPROVED PROJECT REVEGETATION AND LANDSCAPE PLANS SHALL BE IMPLEMENTED AS SOON AS POSSIBLE, FOLLOWING COMPLETION OF ANY SOIL-DISTURBING ACTIVITIES. 5.EXPOSED GROUNDS THAT ARE PLANNED TO BE REWORKED AT DATES GREATER THAN 1 MONTH AFTER INITIAL GRADING SHALL BE SOWN WITH A FAST GERMINATING, NON-INVASIVE, GRASS SEED AND WATERED UNTIL VEGETATION IS ESTABLISHED. 6.ALL DISTURBED SOIL AREAS NOT SUBJECT TO REVEGETATION SHALL BE STABILIZED USING APPROVED CHEMICAL SOIL BINDERS, JUTE NETTING, OR OTHER METHODS APPROVED IN ADVANCE BY THE SLOAPCD. 7.ALL ROADWAYS, DRIVEWAYS, SIDEWALKS, ETC. TO BE PAVED SHALL BE COMPLETED AS SOON AS POSSIBLE. IN ADDITION, BUILDING PADS SHALL BE LAID AS SOON AS POSSIBLE AFTER GRADING UNLESS SEEDING OR SOIL BINDERS ARE USED. 8.VEHICLE SPEED FOR ALL CONSTRUCTION VEHICLES SHALL NOT EXCEED 15 MPH ON ANY UNPAVED SURFACE AT THE CONSTRUCTION SITE. 9.ALL TRUCKS HAULING DIRT, SAND, SOIL, OR OTHER LOOSE MATERIALS ARE TO BE COVERED OR SHALL MAINTAIN AT LEAST 2 FEET OF FREEBOARD (MINIMUM VERTICAL DISTANCE BETWEEN TOP OF LOAD AND TOP OF TRAILER) IN ACCORDANCE WITH CALIFORNIA VEHICLE CODE (CVC) SECTION 23114. 10.“TRACK OUT” IS DEFINED AS SAND OR SOIL THAT ADHERES TO AND/OR AGGLOMERATES ON THE EXTERIOR SURFACES OF MOTOR VEHICLES AND/OR EQUIPMENT (INCLUDING TIRES) THAT MAY THEN FALL ONTO ANY HIGHWAY OR STREET AS DESCRIBED IN CVC SECTION 23113 AND CALIFORNIA WATER CODE (CWC) SECTION 13304. TO PREVENT TRACK OUT, DESIGNATE ACCESS POINTS AND REQUIRE ALL EMPLOYEES, SUBCONTRACTORS, AND OTHERS TO USE THEM. INSTALL AND OPERATE A “TRACK-OUT PREVENTION DEVICE” WHERE VEHICLES ENTER AND EXIT UNPAVED ROADS ONTO PAVED STREETS. THE TRACK-OUT PREVENTION DEVICE CAN BE ANY DEVICE OR COMBINATION OF DEVICES THAT ARE EFFECTIVE AT PREVENTING TRACK OUT, LOCATED AT THE POINT OF INTERSECTION OF AN UNPAVED AREA AND A PAVED ROAD. RUMBLE STRIPS OR STEEL PLATE DEVICES NEED PERIODIC CLEANING TO BE EFFECTIVE. IF PAVED ROADWAYS ACCUMULATE TRACKED-OUT SOILS, THE TRACK-OUT PREVENTION DEVICE MAY NEED TO BE MODIFIED. 11.SWEEP STREETS AT THE END OF EACH DAY IF VISIBLE SOIL MATERIAL IS CARRIED ONTO ADJACENT PAVED ROADS. WATER SWEEPERS SHALL BE USED WITH RECLAIMED WATER WHERE FEASIBLE. ROADS SHALL BE PRE-WETTED PRIOR TO SWEEPING WHEN FEASIBLE. 12.ALL PM10 MITIGATION MEASURES REQUIRED SHOULD BE SHOWN ON GRADING AND BUILDING PLANS. 13.THE CONTRACTOR OR BUILDER SHALL DESIGNATE A PERSON OR PERSONS WHOSE RESPONSIBILITY IS TO ENSURE ANY FUGITIVE DUST EMISSIONS DO NOT RESULT IN A NUISANCE AND TO ENHANCE THE IMPLEMENTATION OF THE MITIGATION MEASURES AS NECESSARY TO MINIMIZE DUST COMPLAINTS AND REDUCE VISIBLE EMISSIONS BELOW THE SLOAPCD'S LIMIT OF 20% OPACITY FOR GREATER THAN 3 MINUTES IN ANY 60-MINUTE PERIOD. THEIR DUTIES SHALL INCLUDE HOLIDAYS AND WEEKEND PERIODS WHEN WORK MAY NOT BE IN PROGRESS (FOR EXAMPLE, WIND-BLOWN DUST COULD BE GENERATED ON AN OPEN DIRT LOT). THE NAME AND TELEPHONE NUMBER OF SUCH PERSONS SHALL BE PROVIDED TO THE SLOAPCD COMPLIANCE DIVISION PRIOR TO THE START OF ANY GRADING, EARTHWORK, OR DEMOLITION (CONTACT TIM FUHS AT 805-781-5912). AQ-3 GEOLOGIC EVALUATION. PRIOR TO INITIATION OF GROUND-DISTURBING ACTIVITIES, THE APPLICANT SHALL RETAIN A REGISTERED GEOLOGIST TO CONDUCT A GEOLOGIC EVALUATION OF THE PROPERTY, INCLUDING SAMPLING AND TESTING FOR NOA IN FULL COMPLIANCE WITH SLOAPCD REQUIREMENTS AND THE CARB ATCM FOR CONSTRUCTION, GRADING, QUARRYING, AND SURFACE MINING OPERATIONS (17 CCR 93105). THIS GEOLOGIC EVALUATION SHALL BE SUBMITTED TO THE CITY COMMUNITY DEVELOPMENT DEPARTMENT UPON COMPLETION. IF THE GEOLOGIC EVALUATION DETERMINES THAT THE PROJECT WOULD NOT HAVE THE POTENTIAL TO DISTURB NOA, THE APPLICANT MUST FILE AN ASBESTOS ATCM EXEMPTION REQUEST WITH THE SLOAPCD. BIOLOGICAL RESOURCES BIO-1 NESTING BIRDS AND RAPTORS. SITE PREPARATION, GROUND DISTURBANCE, AND CONSTRUCTION ACTIVITIES INCLUDING ANY TREE TRIMMING AND VEGETATION REMOVAL SHALL BE CONDUCTED OUTSIDE OF THE MIGRATORY BIRD NESTING SEASON (FEBRUARY 15 THROUGH OCTOBER 31). IF SUCH ACTIVITIES CANNOT BE AVOIDED DURING THIS PERIOD, A COUNTY-APPROVED QUALIFIED BIOLOGIST SHALL CONDUCT A PRECONSTRUCTION NESTING BIRD SURVEY NO SOONER THAN 1-4 WEEKS PRIOR TO TREE REMOVAL ACTIVITIES AND SHALL VERIFY WHETHER MIGRATORY BIRDS ARE NESTING IN THE SITE. IF NESTING ACTIVITY IS DETECTED, THE FOLLOWING MEASURES SHALL BE IMPLEMENTED: 1.THE PROJECT SHALL BE MODIFIED VIA THE USE OF PROTECTIVE BUFFERS, DELAYING CONSTRUCTION ACTIVITIES, OR OTHER METHODS DESIGNATED BY THE QUALIFIED BIOLOGIST TO AVOID DIRECT TAKE OF IDENTIFIED NESTS, EGGS, AND/OR YOUNG PROTECTED UNDER THE MBTA AND/OR CALIFORNIA FISH AND GAME CODE. 2.THE QUALIFIED BIOLOGIST SHALL MONITOR THE NESTS WITHIN THE VICINITY OF PROJECT- RELATED DISTURBANCES AND DETERMINE IF CONSTRUCTION ACTIVITIES ARE CAUSING BEHAVIORAL CHANGES OR AFFECTING NESTING ACTIVITIES. MONITORING RESULTS SHALL THEN BE UTILIZED TO DEVELOP AN APPROPRIATE BUFFER AROUND THE NEXT SITE TO MINIMIZE DISTURBANCE. CONSTRUCTION ACTIVITIES WITHIN THE BUFFER ZONE SHALL BE PROHIBITED UNTIL THE YOUNG HAVE FLEDGED THE NEST AND ACHIEVED INDEPENDENCE. 3.THE QUALIFIED BIOLOGIST SHALL DOCUMENT ALL ACTIVE NESTS AND SUBMIT A LETTER REPORT TO THE COUNTY DOCUMENTING PROJECT COMPLIANCE WITH THE MBTA, CALIFORNIA FISH AND GAME CODE, AND APPLICABLE PROJECT MITIGATION MEASURES WITHIN 14 DAYS OF SURVEY COMPLETION. BIO-2 ROOSTING BATS. SITE PREPARATION, GROUND DISTURBANCE, AND CONSTRUCTION ACTIVITIES INCLUDING ANY TREE TRIMMING AND/OR VEGETATION REMOVAL SHALL BE CONDUCTED OUTSIDE OF THE TYPICAL BAT MATERNITY ROOSTING AND PUPPING SEASON (FEBRUARY 1 TO AUGUST 31), IF FEASIBLE. IF SITE DISTURBANCE ACTIVITIES ARE TO OCCUR WITHIN THIS SEASON, THE APPLICANT SHALL RETAIN A COUNTY-QUALIFIED BIOLOGIST TO CONDUCT A PRECONSTRUCTION SURVEY WITHIN 14 DAYS PRIOR TO COMMENCEMENT OF PROPOSED SITE DISTURBANCE ACTIVITIES. IF ANY ROOSTING BATS ARE FOUND DURING PRECONSTRUCTION SURVEYS, NO WORK ACTIVITIES SHALL OCCUR WITHIN 100 FEET OF ACTIVE ROOSTS UNTIL BATS HAVE LEFT THE ROOSTS. THE COUNTY-QUALIFIED BIOLOGIST SHALL PREPARE A REPORT AFTER EACH SURVEY AND A COPY OF THE REPORT SHALL BE PROVIDED TO THE COUNTY WITHIN 14 DAYS OF COMPLETION OF EACH SURVEY. IF NO BAT ROOSTING ACTIVITIES ARE DETECTED WITHIN THE PROPOSED WORK AREA, SITE DISTURBANCE AND NOISE-PRODUCING CONSTRUCTION ACTIVITIES MAY PROCEED, AND NO FURTHER MITIGATION IS REQUIRED. Ø MONITORING PROGRAM: THESE CONDITIONS AND MEASURES SHALL BE NOTED ON FINAL MAP AND ALL GRADING AND CONSTRUCTION PLANS. THE CITY COMMUNITY DEVELOPMENT DEPARTMENT AND NATURAL RESOURCES MANAGER SHALL VERIFY COMPLIANCE. TRIBAL CULTURAL RESOURCES TR-1 CULTURALLY AFFILIATED NATIVE AMERICAN MONITOR. A REPRESENTATIVE FROM THE SALINAN TRIBE SHALL BE NOTIFIED PRIOR TO ANY GROUND DISTURBING ACTIVITIES TO PROVIDE FOR ON-SITE MONITORING. IF CULTURAL RESOURCES ARE ENCOUNTERED DURING SUBSURFACE EARTHWORK ACTIVITIES, ALL GROUND DISTURBING ACTIVITIES WITHIN A 25-FOOT RADIUS OF THE FIND SHALL CEASE AND THE CITY SHALL BE NOTIFIED IMMEDIATELY CONSISTENT WITH THE REQUIREMENTS OF MITIGATION MEASURES CR-1 AND CR-2. Ø MONITORING PROGRAM: THIS MEASURE SHALL BE INCORPORATED INTO FINAL MAP AND NOTED ON ALL GRADING AND CONSTRUCTION PLANS. THE CITY COMMUNITY DEVELOPMENT DEPARTMENT SHALL VERIFY COMPLIANCE THROUGH INITIAL AND REGULAR INSPECTIONS. WILDFIRE WF-1 VEGETATION/FUEL MANAGEMENT PLAN. PRIOR TO ISSUANCE OF ANY CONSTRUCTION PERMIT, THE APPLICANT SHALL PROVIDE A VEGETATION/FUEL MANAGEMENT PLAN PREPARED BY A REGISTERED PROFESSIONAL FORESTER OR CERTIFIED ARBORIST FOR EACH LOT. THE PLAN SHALL IDENTIFY FUEL LOAD REDUCTION TECHNIQUES, INCLUDING VEGETATION REMOVAL AND TRIMMING, TO INCREASE DEFENSIBLE SPACE AROUND RESIDENTIAL STRUCTURES AND DRIVEWAYS/ACCESS ROADS. THE PLAN SHALL ALSO IDENTIFY APPROPRIATE STANDARDS FOR INSTALLATION OF NEW LANDSCAPING, SUCH AS REQUIREMENTS FOR DROUGHT-TOLERANT AND FIRE-RESISTANT SPECIES. Ø MONITORING PROGRAM: THIS MEASURE SHALL BE INCORPORATED INTO FINAL MAP AND NOTED ON ALL GRADING AND CONSTRUCTION PLANS. THE CITY COMMUNITY DEVELOPMENT DEPARTMENT SHALL VERIFY COMPLIANCE THROUGH INITIAL AND REGULAR INSPECTIONS. CONDITIONS OF APPROVAL &MITIGATIONSDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:57amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C001-NS.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC0.3 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23 CONDITIONS OF APPROVAL &MITIGATIONSDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:57amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C001-NS.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC0.4 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23SHEET C0.1 SHEET C0.1 SHEET C1.0 SHEET C1.1 GAS LINES NOT PROPOSED SHEET C1.0 SHEET C0.2 SHEET C1.0 SHEET C1.0 SHEET C1.0 S13°41'28"E 144.61'N0°00'53"E 100.87'S3°02'24"E 101.03'N89°56'08"W 200.35' W W W W W W W W W W W W W W W W SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSN82°31'28" W 1 1 9 . 8 8 ' S89°56'20"E 94.62' N89°56'08"W 100.00'N0°00'53"E 125.00'SS W W W W W W W W W W W W W W W W W W W W SSSSSSSSSSSSSS SSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS±18.0%15.0% 400 39 5 (11.0%)(10.0%)(12.5%)405410415 STONE TOP = 400.55 CHAMBER TOP = 399.55 CHAMBER BOT = 395.80 STONE BOT = 395.05 401.05 TG 399.90 INV 403.00 TG 401.85 INV 398.40 INV 398.15 INV 420 (421.56 EC) 421.56 AC (421.06 ER) (421.81 EC) 421.64 AC 410.19 FS (402.35 EP) (398.60 EP)(398.54 EP) (394.24 EP) (393.45 EP) (396.96 EP) (420.70 ER) (396.22 EP) (398.23 EP) (397.48 EP) 404.12 FS 399.50 FS 405.38 FS (404.0 EP) 405.21 FS 422.00 TW (422.00 EC) 421.83 AC 409.92 FS 403.62 FS 419.79 FS419.79 FS 416.65 FS416.89 FS 422.00 TW 419.72 FS 422.00 TW 419.0 FG 422.00 TW (421.8 EG) 422.00 TW 418.96 FS PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF PERF SERRANO LANE1 1 1 1 2 3 4 4 5 5 5 5 6 6 7 7 7 8 9 9 9 10 10 10 11 11 11 12 12 12 20.00'20.00' 20.00' 13 13 13 13 14 14 15 16 1 17 17 17 1 GRADING, DRAINAGE & UTILITYPLANDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:55amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C101-GD.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC1.1 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23SPECIFIC CONSTRUCTION NOTES: 1 CONSTRUCT ASPHALT CONCRETE (AC) PAVEMENT (LIGHT TRAFFIC) SECTION PER DETAIL. DRIVEWAY SLOPE SHALL FOLLOW CITY FIRE STANDARDS. 2 INSTALL (3) NEW 1" SERVICE LINE PER THE CITY OF SAN LUIS OBISPO STANDARD DETAIL 6210, C1.3. CAP WATER SERVICE LATERAL FOR FUTURE CONNECTION. METER BOX SHOWN FOR COORDINATION PURPOSES ONLY. 3 INSTALL NEW 4" DR-14 C900 FIRE WATER SERVICE LINE PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 6310, C1.3. CAP FIRE WATER SERVICE LATERAL FOR FUTURE CONNECTION. FIRE HYDRANT SHOWN FOR COORDINATION PURPOSES ONLY. 4 EXISTING SEWER LATERAL TIE-INS PER PERMIT ENCR-0981-2021. 5 MATCH EXISTING. CONTRACTOR TO VERIFY MATCH LOCATION AND ELEVATION PRIOR TO CONSTRUCTION TO ENSURE THEY ARE CONSISTENT WITH PLAN. CONTACT ENGINEER IF DISCREPANCIES ARISE. 6 CONNECT TO EXISTING 8" WATER MAIN PER CITY OF SAN LUIS OBISPO STANDARD DETAILS. CONTRACTOR TO POTHOLE AND FIELD VERIFY EXISTING PIPE LOCATION AND DEPTH PRIOR TO CONSTRUCTION. 7 PROTECT-IN-PLACE EXISTING ASPHALT PAVEMENT. 8 PROTECT-IN-PLACE EXISTING CONCRETE PAVEMENT. 9 PROTECT-IN-PLACE EXISTING SEWER MAIN. CONTRACTOR TO POTHOLE AND FIELD VERIFY EXISTING PIPE LOCATION AND DEPTH PRIOR TO CONSTRUCTION. 10 PROTECT-IN-PLACE EXISTING SEWER LATERAL. CONTRACTOR TO POTHOLE AND FIELD VERIFY EXISTING PIPE LOCATION AND DEPTH PRIOR TO CONSTRUCTION. 11 PROTECT-IN-PLACE EXISTING OVERHEAD ELECTRICAL LINES. 12 PROTECT-IN-PLACE EXISTING GAS LINE. 13 TREE TO BE IMPACTED. CONTRACTOR TO FOLLOW GUIDELINES FROM CITY ARBORIST. 14 INSTALL 8" WIDE 'ACO' TRENCH DRAIN PER MANUFACTURER'S RECOMMENDATIONS. GRATE TO BE TRAFFIC RATED. 15 INSTALL 6" SDR-35 PVC STORM DRAIN PIPE. 16 INSTALL MC-3500 'STORMTECH' CHAMBER PER MANUFACTURER'S RECOMMENDATIONS. INSTALL AT A MINIMUM (2) CHAMBERS, (2) END CAPS, 12" STONE ABOVE, AND 9" STONE BELOW FOR A MINIMUM 450 CUBIC FEET OF STORAGE. 17 CONSTRUCT 4'-0" MAX HEIGHT WALL. HEIGHT OF WALL + FENCE SHALL NOT EXCEED 9'-0". CONNECT 4" SUBDRAIN TO (2) SURFACE DRAIN INLETS AND OUTLET WITH 4" SOLID PIPE AS SHOWN. PROVIDE ROCK DISSIPATOR AT PIPE OUTLET. #SEE BELOWMATERIALS ASPHALT CONCRETE SURFACE COURSE CRUSHED AGGREGATE BASE COURSE THICKNESS SECTION CALTRANS SPECIFICATIONS 2.5" 6" SECTION 39 * SECTION 26, CLASS 2 * ** AC PAVING *** (SEE BELOW) CLASS II AGGREGATE BASE (SEE BELOW) SUBGRADE TO BE SCARIFIED TO A DEPTH OF 12", MOISTURE CONDITIONED, AND RECOMPACTED TO A MINIMUM OF 95% PER SOILS ENGINEERING REPORT FOR THIS PROJECT. NOTES: *COMPACTION TO A MINIMUM DENSITY OF 95 PERCENT **PAVEMENT SECTION IS TO BE BASED ON A T.I. OF 4.5. ACTUAL SECTION SHALL BE DETERMINED BY R-VALUES TAKEN DURING CONSTRUCTION. *** CROSS SLOPES NOT TO EXCEED 2% ON ALL WALKWAYS, AND NOT TO EXCEED 2% IN ANY DIRECTION IN PLAZA AREAS.1"AC PAVING OVERLAY EXISTING AC PAVING MATCH EXISTING AC PAVING WITH FLUSH EDGE AC PAVING SECTION SCALE = NONE PAVEMENT GRINDING DETAIL ( IN FEET ) 1 INCH = FT. 5 1010 10 200 ETC OVERHEAD CONDUITS GAS LINEG SS SEWER LINE WATER LINEW W WATER LINE INDEX CONTOUR340 FENCE ELEVATION347.20 LEGEND: SS SANITARY SEWER PROPERTY LINE SLOPE & DIRECTION OF FLOW2% INDEX CONTOUR340 INTERMEDIATE CONTOUR342 ELEVATION(347.20) SLOPE & DIRECTION OF FLOW(2%) PROPOSED EXISTING ASPHALT CONCRETE (E) ASPHALT CONCRETE TG TOP OF GRATE EP EDGE OF PAVEMENT SLOPES L LENGTH INV INVERT GB GRADE BREAK EXISTING(E) FS FINISH SURFACE EXISTING GROUNDEG FG FINISH GRADE TC TOP OF CURB SDMH HDPE HIGH DENSITY POLYETHELENE STORM DRAIN MANHOLE RIM RIM OR TOP OF FRAME HOLDING GRATE TW TOP OF WALL ABBREVIATIONS: FL FLOW LINE SSMH SANITARY SEWER MANHOLE GRIND/OVERLAY EXTENTS 1 1 PERF 4" WALL SUBDRAIN SD STORM DRAIN N0°00'53"E 100.87'S89°56'20"E 94.62' 15.0% 400 39 5 (11.0%)(10.0%)(12.5%)405410410.19 FS (402.35 EP) (398.60 EP)(398.54 EP) (394.24 EP) (393.45 EP) (396.96 EP) (396.22 EP) (398.23 EP) (397.48 EP) 404.12 FS 399.50 FS 405.38 FS (404.0 EP) 405.21 FS 409.92 FS 403.62 FS 419.79 FS 416.65 FS SERRANO LANE10.00' T R A V E L WIDTH 10.00' TRAVELWIDTH35.00'R37.00 'N0°00'53"E 100.87'S89°56'20"E 94.62'N0°00'53"E 125.00'15.0% 400 (11.0%)(10.0%)(12.5%)405410410.19 FS (402.35 EP) (398.60 EP)(398.54 EP) (398.23 EP) (397.48 EP) 404.12 FS 399.50 FS 405.38 FS (404.0 EP) 405.21 FS 409.92 FS 403.62 FS 419.79 FS 416.65 FS SERRANO LANE10.00' TRAVELWIDTH35.00'10.00' TRAVEL WIDTH R37.00'FIRE ACCESSDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:56amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C101-GD.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC1.2 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23( IN FEET ) 1 INCH = FT. 5 1010 10 200 ETC OVERHEAD CONDUITS GAS LINEG SS SEWER LINE WATER LINEW W WATER LINE INDEX CONTOUR340 FENCE ELEVATION347.20 LEGEND: SS SANITARY SEWER PROPERTY LINE SLOPE & DIRECTION OF FLOW2% INDEX CONTOUR340 INTERMEDIATE CONTOUR342 ELEVATION(347.20) SLOPE & DIRECTION OF FLOW(2%) PROPOSED EXISTING ASPHALT CONCRETE (E) ASPHALT CONCRETE TG TOP OF GRATE EP EDGE OF PAVEMENT SLOPES L LENGTH INV INVERT GB GRADE BREAK EXISTING(E) FS FINISH SURFACE EXISTING GROUNDEG FG FINISH GRADE TC TOP OF CURB SDMH HDPE HIGH DENSITY POLYETHELENE STORM DRAIN MANHOLE RIM RIM OR TOP OF FRAME HOLDING GRATE TW TOP OF WALL ABBREVIATIONS: FL FLOW LINE SSMH SANITARY SEWER MANHOLE DETAIL SHEETDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:56amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C101-GD.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC1.3 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/231 400 39 5 405410415 420 SERRANO LANETC-1 SE-7 SE-7 WE-1 WE-1 WE-1 SE-5 SE-5 WE-1 EC-3 EC-3 SE-5 EROSION CONTROL PLANDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:59amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C201-EC.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC2.1 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23( IN FEET ) 1 INCH = FT. 5 1010 10 200 EROSION CONTROL NOTES: SYMBOL CASQA# DESCRIPTION DETAIL/SHEET INSTALL FIBER ROLLS PER MANUFACTURERS SPECIFICATIONS.A/C2.2 INSTALL SILT FENCE PER MANUFACTURER SPECIFICATIONS.B/C2.2 INSTALL HYDROMULCH TO DISTURBED SLOPES.H/C2.2 INSTALL STABILIZED CONSTRUCTION ENTRANCE/EXIT.C/C2.2 INSTALL GRAVEL BAG BERM. PROVIDE WIND EROSION CONTROL.F/C2.2 PROVIDE GEOTEXTILE MAT, NORTH AMERICAN GREEN SC150. PROVIDE STREET SWEEPING & VACUUMING.G/C2.2 MATERIAL DELIVERY & STORAGE D/C2.2 CONCRETE WASHOUT J/C2.2 * NOT ALL EROSION CONTROL MEASURES LISTED ABOVE ARE USED ON THIS PLAN, BUT ARE PROVIDED FOR THE FUTURE USE BY THE CONTRACTOR PRIOR OR DURING CONSTRUCTION. SE-5 SE-1 EC-3 TC-1 SE-6 WE-1 EC-7 SE-7 WM-1 WM-8 1 EROSION CONTROL DETAILSDESIGNED: SHEET: DATE: JOB NUMBER:PLOT BY: AGE03PLOT DATE: Jan 02, 2024 - 9:59amDrawing name: N:\2018\18133-SeranoHeights\Engineering\FinalMap\Condocs\18133FM-C201-EC.dwgENGINEER OF RECORD: DATE:NO.REVISIONDATEC2.2 DRAWN: SJS DLL 18133 FEBRUARY 24, 2022163 SERRANO HEIGHTSSERRANO LANE, SAN LUIS OBISPO, CA 934011.RETAINING WALL ADDITION01/02/23DITCH CRUSHED AGGREGATE GREATER THAN 3" BUT SMALLER THAN 6" ORIGINAL GRADE 12" MIN UNLESS OTHERWISE SPECIFIED BY A GEOTECHNICAL ENGINEER SECTION A-A PLAN STABILIZED CONSTRUCTION ENTRANCE/EXIT MATCH EXISTING GRADE 50' OR FOUR TIMES THE CIRCUMFERENCE OF THE LARGEST CONSTRUCTION VEHICLE TIRE, WHICHEVER IS GREATER. -NTS- AA INSTALLATION PROCEDURES: PRE-ASSEMBLED SILT FENCE -NTS- 3 4" x 2" x 2' WOOD STAKE IN CENTER OF ROLL (2"-3" EXPOSED AFTER DRIVING STAKE) NOTE: PLACE NET-WRAPPED FIBER ROLL IN TRENCH. WATTLE TO BE TIGHTLY BUTTED END TO END BUT NOT OVERLAPPING. MINIMUM 6 STAKES PER 25' ROLL. 4' MA X 9"Ø x 25' LONG FIBER ROLL 3"-5" TRENCH FIBER ROLLS -NTS- DESCRIPTION AND PURPOSE PREVENT, REDUCE, OR ELIMINATE THE DISCHARGE OF POLLUTANTS FROM MATERIAL DELIVERY AND STORAGE TO THE STORMWATER SYSTEM OR WATERCOURSES BY MINIMIZING THE STORAGE OF HAZARDOUS MATERIALS ONSITE, STORING MATERIALS IN WATERTIGHT CONTAINERS AND/OR A COMPLETELY ENCLOSED DESIGNATED AREA, INSTALLING SECONDARY CONTAINMENT, CONDUCTING REGULAR INSPECTIONS, AND TRAINING EMPLOYEES AND SUBCONTRACTORS. MATERIAL STORAGE AREAS AND PRACTICES ·CHEMICALS MUST BE STORED IN WATER TIGHT CONTAINERS WITH APPROPRIATE SECONDARY CONTAINMENT OR IN A STORAGE SHED. ·WHEN MATERIAL STORAGE AREA IS LOCATED ON BARE SOIL, THE AREA SHOULD BE LINED AND BERMED. ·USE CONTAINMENT PALLETS OR OTHER PRACTICAL AND AVAILABLE SOLUTIONS, SUCH AS STORING MATERIALS WITHIN NEWLY CONSTRUCTED BUILDINGS OR GARAGES, TO MEET MATERIAL STORAGE REQUIREMENTS. ·STACK ERODIBLE LANDSCAPE MATERIAL ON PALLETS AND COVER WHEN NOT IN USE. ·CONTAIN ALL FERTILIZERS AND OTHER LANDSCAPE MATERIALS WHEN NOT IN USE. ·EMPLOYEES TRAINED IN EMERGENCY SPILL CLEANUP PROCEDURES MUST BE PRESENT WHEN DANGEROUS MATERIALS OR LIQUIDS ARE UNLOADED. ·A TEMPORARY CONTAINMENT FACILITY SHOULD BE IMPERVIOUS TO THE MATERIALS STORED THEREIN FOR A MINIMUM CONTACT TIME OF 72 HOURS. ·SUFFICIENT SEPARATION SHOULD BE PROVIDED BETWEEN STORED CONTAINERS TO ALLOW FOR SPILL CLEANUP AND EMERGENCY RESPONSE ACCESS. ·MATERIALS SHOULD BE COVERED PRIOR TO, AND DURING RAIN EVENTS. ·PROPER STORAGE INSTRUCTIONS SHOULD BE POSTED AT ALL TIMES IN AN OPEN AND CONSPICUOUS LOCATION. ·AN AMPLE SUPPLY OF APPROPRIATE SPILL CLEAN UP MATERIAL SHOULD BE KEPT NEAR STORAGE AREAS. INSPECTION AND MAINTAINENCE ·KEEP STORAGE AREAS CLEAN AND WELL ORGANIZED, INCLUDING A CURRENT LIST OF ALL MATERIALS ONSITE. ·INSPECT LABELS ON CONTAINERS FOR LEGIBILITY AND ACCURACY. ·REPAIR OR REPLACE PERIMETER CONTROLS, CONTAINMENT STRUCTURES, COVERS, AND LINERS AS NEEDED TO MAINTAIN PROPER FUNCTION. WOODEN PALLET STORAGE SHED WOODEN PALLET WATER TIGHT LIQUID OR SOLIDS BARREL STORAGE MATERIAL DELIVERY & STORAGE A B D STOCKPILING PERIMETER OF FIBER ROLLS PERIMETER OF FIBER ROLLS 12" FROM BASE OF STOCKPILE TO THE INSIDE FACE OF THE FIBER ROLL DESCRIPTION AND PURPOSE PREVENT, REDUCE, OR ELIMINATE THE DISCHARGE OF SEDIMENT FROM STOCKPILES TO THE STORMWATER SYSTEM OR WATERCOURSES BY PROVIDING TARPS TO AS COVERAGE TO MINIMIZE DUST AND PROVIDING PERIMETER CONTROLS SUCH AS FIBER ROLLS TO CONTROL THE SEDIMENT AS PLACED. STOCKPILING AREAS AND PRACTICES ·SUFFICIENT SEPARATION SHOULD BE PROVIDED BETWEEN THE BASE OF THE STOCKPILE AND THE SURROUNDING PERIMETER CONTROL MEASURE TO ALLOW FOR SPILL SETTLEMENT AND SHIFTS WITHIN THE STOCKPILE ·STOCKPILES SHALL BE COVERED WITH TARPS AND HELD IN PLACE WITH GRAVEL BAGS PRIOR TO, AND DURING RAIN EVENTS. ·PROPER STORAGE INSTRUCTIONS SHOULD BE POSTED AT ALL TIMES IN AN OPEN AND CONSPICUOUS LOCATION. ·AN AMPLE SUPPLY OF APPROPRIATE TARPS, FIBER ROLLS AND GRAVEL BAGS SHOULD BE KEPT NEAR STORAGE AREAS. INSPECTION AND MAINTAINENCE ·KEEP STORAGE AREAS CLEAN AND WELL ORGANIZED, INCLUDING A CURRENT LIST OF ALL MATERIALS ONSITE. ·REPAIR OR REPLACE PERIMETER CONTROLS, COVERS, AND LINERS AS NEEDED TO MAINTAIN PROPER FUNCTION.FLOWVALLEY GUTTER/SWALE FLOW FLOW DESCRIPTION AND PURPOSE RETAINS THE SEDIMENT, AND RELEASES THE WATER AS SHEET FLOW. GRAVEL BAG PRACTICES ·INSTALL AT INTERVALS OF 50 TO 70 FEET ·INSTALL IN A "CHEVRON" FASHION, FORCING THE RUNOFF TOWARDS THE EDGE-OF-PAVEMENT, CURB FACE, GUTTER FLOWLINE OR VALLEY GUTTER/SWALE FLOW LINE INSPECTION AND MAINTAINENCE ·REPLACE WHEN BROKEN ·REMOVE ACCUMULATED SEDIMENT WHEN ONE-THIRD BARRIER HEIGHT FDUST/WIND EROSION CONTROL DESCRIPTION AND PURPOSE STABILIZING MATERIALS ARE APPLIED TO THE DISTURBED SOIL SURFACE TO PREVENT THE TRANSPORT OF SOIL FROM EXPOSED SURFACES ON CONSTRUCTION SITES EITHER BY WIND OR STORM WATER RUNOFF. DUST/WIND EROSION CONTROL PRACTICES ·USE OF WATER TRUCKS TO APPLY WATER TO THE DISTURBED SOILS ·APPLY WATER, OR AN ALTERNATIVE METHOD, TO THE DISTURBED SOILS THREE TIMES A DAY (MINIMUM), ONCE IN THE MORNING (7 AM - 10 AM), ONCE DURING THE AFTERNOON (10 AM - 1 PM), AND ONCE MORE AT THE END OF THE DAY INSPECTION AND MAINTAINENCE ·INSPECT AREAS WITH EXCESSIVE WIND, VEHICULAR TRAFFIC OR WHEN RAIN IS EXPECTED ·APPLY SOIL STABILIZERS AT DESCRIBED INTERVALS, AND BASED ON NEED GSTREET SWEEPING AND VACUUMING DESCRIPTION AND PURPOSE REMOVAL OF SEDIMENT, DEBRIS AND MATERIALS TRACKED OUT FROM THE SITE THROUGH THE USE OF EITHER A STREET SWEEPER OR MANUAL LABOR. STREET SWEEPING & VACUUMING PRACTICES ·SHALL OCCUR DURING PHASES OF CONSTRUCTION WHICH CONTAIN REOCCURRING VEHICULAR TRAFFIC TO AND FROM THE SITE, WHICH INCLUDES ALL VEHICLE SIZES, WHEN THERE ARE STILL EXPOSED DISTURBED SOILS ·CLEANING ACTIVITIES SHALL OCCUR AT A MINIMUM ONCE A DAY AT THE END OF DAY ·USE OF WATER TO PRESSURE WASH SEDIMENT BUILD-UP ON PRIVATE ROADS OR PUBLIC STREETS SHALL NOT BE ALLOWED INSPECTION AND MAINTAINENCE ·INSPECT PUBLIC/PRIVATE STREETS FOR SEDIMENTATION BUILD-UP ·DEDICATE PERSONNEL AT THE END OF EACH SHIFT TO WALK THE PERIMETER OF THE SITE AND DOWNSTREAM STREET SECTIONS FOR SEDIMENTATION BUILD-UP HHYDROSEEDING / HYDROMULCHING DESCRIPTION AND PURPOSE ESTABLISH A PERMANENT PERENNIAL VEGETATIVE COVER ON AREAS THAT HAVE BEEN DISTURBED BY CONSTRUCTION ACTIVITIES. ESTABLISHMENT OF PERMANENT VEGETATION REDUCES EROSION BY SLOWING RUNOFF VELOCITIES, ENHANCES INFILTRATION AND TRANSPIRATION. HYDROMULCH/HYDROSEEDING PRACTICES ·APPLY TO ALL DISTURBED SLOPES, CUT AND FILL AREAS, WATERWAYS (SWALES) AND LANDSCAPE CORRIDORS INSPECTION AND MAINTAINENCE ·NEW VEGETATION SHOULD BE SUPPLIED WITH SUPPLEMENTAL WATER UNTIL FIRMLY ESTABLISHED ·CUTTING OR MOWING GRASSES WILL ENCOURAGE THE ESTABLISHMENT AND SPREAD OF THE GRASS ·INSPECT SEEDED AREAS FOR FAILURES AND RESEEDED, FERTILIZED, AND MULCHED WITHIN THE PLANTING SEASON USING HALF THE ORIGINAL APPLICATION RATES ROADWAYS, CURBS, GUTTERS C E SECTION A-A SCALE: NTS TWO LAYERS OF GRAVEL BAGS EXISTING SURFACE FILTER FABRIC EXISTING SURFACE DRAIN INLET RIM DRAIN INLET NOTES: ·FILTER FABRIC TO EXTEND 3" PAST THE DRAIN INLET RIM & TO BE HELD IN PLACE BY OVERLAYING GRAVEL BAGS. ·REMOVE ACCUMULATED SEDIMENT WHEN ONE-THIRD OF THE BARRIER HEIGHT. ·INSPECT BEFORE & AFTER STORM EVENTS. TWO OVERLAPPING LAYERS OF GRAVEL BAGS IDRAIN INLET PROTECTION J AA PLAN 10 MIL PLASTIC LINING 10' MIN STRAW BALE (TYP)VARIESSTAKE (TYP) WOOD OR METAL STAKES (2 PER BALE) STAPLES (2 PER BALE) STRAW BALE 10 MIL PLASTIC LINING NATIVE MATERIAL (OPTIONAL) BINDING WIRE CONCRETE WASHOUT SECTION A-A CONCRETE WASHOUT SIGN (OR EQUIVALENT) STAPLE DETAIL8"2" 12-GA MIN. STEEL WIRE3'3'BLACK LETTERS 12" MIN. WOOD POST (4" x 4" x 8') PLYWOOD 4' x 2' PAINTED WHITE LAG SCREWS (1/2") NOTES: 1.ACTUAL LAYOUT DETERMINED IN THE FIELD. 2.THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30' OF THE TEMPORARY CONCRETE WASHOUT FACILITY. CONCRETE WASHOUT 1 From:Google Calendar <calendar-notification@google.com> on behalf of Sent:Monday, April 24, 2023 9:38 AM To:Nelson, Trevor Subject:Declined: 163 Serrano Heights @ Tue Apr 25, 2023 10:30am - 11am (PDT) (Nelson, Trevor) Attachments:invite.ics This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. has declined this invitation. Changing time to 10:30 When Tuesday Apr 25, 2023 ⋅ 10:30am – 11am (Pacific Time - Los Angeles) Organizer Nelson, Trevor tnelson@slocity.org Guests - creator Buckley, Nick - optional View all guest info Invitation from Google Calendar You are receiving this email because you are an attendee on the event. To stop receiving future updates for this event, decline this event. Forwarding this invitation could allow any recipient to send a response to the organizer, be added to the guest list, invite others regardless of their own invitation status, or modify your RSVP. Learn more 1 From:Nelson, Trevor Sent:Friday, September 8, 2023 2:45 PM To:Hurley, Brian Cc:Buckley, Nick Subject:163 Serrano Heights Dr #A Brian, Please discuss with Nick or I prior to heading out for Final. Thank you. Trevor Nelson Supervising Building Inspector Community Development 919 Palm St, San Luis Obispo, CA 93401-3218 E tnelson@slocity.org T 805.781.7153 2 C 805.431.7160 slocity.org Stay connected with the City by signing up for e-notifications 1 Subject:163 Serrano Heights Start: Recurrence:(none) Organizer:Nelson, Trevor This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. This was what I received the day before our agreed upon meeting at 10am Tuesday. I was available at the agreed upon time of 10am, Not at 10:30 with one day notice and no explanation or a request. ---------- Forwarded message --------- From: Nelson, Trevor <tnelson@slocity.org> Date: Mon, Apr 24, 2023 at 8:12 AM Subject: 163 Serrano Heights To: John Rourke < Cc: Buckley, Nick <nbuckley@slocity.org> Changing time to 10:30 Notice to Correct Code Violation(s)/Notice of Violation (Courtesy Warning Prior to Issuance of Administrative Citation) May 12, 2023 John Rourke 281 Broad St San Luis Obispo, CA 93405 SUBJECT ADDRESS: 163 Serrano Heights, San Luis Obispo, CA 93405 APN: 052-061-049 Code Case #: CODE-000063-2023 Dear Property Owner, On April 10th, 2023, City of San Luis Obispo Community Development Department staff noted the following violations of the San Luis Obispo Municipal Code or other relevant codes at the above listed address: 1. Permit Required (SLOMC 15.02.020, California Building Code 105.1) “Any owner or owner’s authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the building official and obtain the required permit.” Resolution: Permit or remove the retaining wall/fence combination. 2. Fences, Walls, and Hedges (SLOMC 17.70.070[C]) “Fences, walls or hedges may be placed within required yards, provided they do not exceed maximum height limitations and comply with the following standards: 1. The maximum height of a fence, wall, or hedge shall not exceed six feet; except within any front setback, the maximum fence, wall, or hedge shall be as shown in Figure 3-3. Corrective Action: Reduce the fence height to the allowed fence height according to the fence height standards. Or obtain building permit. ALL REQUIRED WORK MUST BE COMPLETED WITHIN 90 DAYS OF PERMIT ISSUANCE. We request that you voluntarily take action to correct the above noted violation(s) no later than 6/12/2022. These violations constitute a public nuisance and must be abated. Failure to correct the violation(s) by the specified date will result in the issuance of an Administrative Citation requiring payment of FINES in accordance with SLOMC Chapter 1.24. For Municipal Code violations that remain uncorrected after issuance of an Administrative Citation, the City may seek enforcement by other civil or criminal remedies. Any person having a title interest in the property may request a Director’s review of this Notice by completing the enclosed Request for Director’s Review Form and submitting it to the Community Development Department via email at code@slocity.org or to 919 Palm Street, San Luis Obispo, CA 93401, within five (5) days of the date of this Notice. This Notice shall be deemed final unless you timely file a Request for Director’s Review. We look forward to working with you to resolve these violations and would like to thank you for your efforts to maintain your property and to help preserve the safety and beauty of our community. If you have questions, please contact the undersigned Officer at (805) 783-7872 or nbuckley@slocity.org. Sincerely, ____________________________ Nick Buckley, Code Enforcement Officer Cc: Enclosures: Request for Directors Review Notice to Correct Code Violation(s)/Notice of Violation (Courtesy Warning Prior to Issuance of Administrative Citation) May 12, 2023 John Rourke 281 Broad St San Luis Obispo, CA 93405 SUBJECT ADDRESS: 163 Serrano Heights, San Luis Obispo, CA 93405 APN: 052-061-049 Code Case #: CODE-000063-2023 Dear Property Owner, On April 10th, 2023, City of San Luis Obispo Community Development Department staff noted the following violations of the San Luis Obispo Municipal Code or other relevant codes at the above listed address: 1. Permit Required (SLOMC 15.02.020, California Building Code 105.1) “Any owner or owner’s authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the building official and obtain the required permit.” Resolution: Permit or remove the retaining wall/fence combination. 2. Fences, Walls, and Hedges (SLOMC 17.70.070[C]) “Fences, walls or hedges may be placed within required yards, provided they do not exceed maximum height limitations and comply with the following standards: 1. The maximum height of a fence, wall, or hedge shall not exceed six feet; except within any front setback, the maximum fence, wall, or hedge shall be as shown in Figure 3-3. Corrective Action: Reduce the fence height to the allowed fence height according to the fence height standards. Or obtain building permit. ALL REQUIRED WORK MUST BE COMPLETED WITHIN 90 DAYS OF PERMIT ISSUANCE. We request that you voluntarily take action to correct the above noted violation(s) no later than 6/12/2022. These violations constitute a public nuisance and must be abated. Failure to correct the violation(s) by the specified date will result in the issuance of an Administrative Citation requiring payment of FINES in accordance with SLOMC Chapter 1.24. For Municipal Code violations that remain uncorrected after issuance of an Administrative Citation, the City may seek enforcement by other civil or criminal remedies. Any person having a title interest in the property may request a Director’s review of this Notice by completing the enclosed Request for Director’s Review Form and submitting it to the Community Development Department via email at code@slocity.org or to 919 Palm Street, San Luis Obispo, CA 93401, within five (5) days of the date of this Notice. This Notice shall be deemed final unless you timely file a Request for Director’s Review. We look forward to working with you to resolve these violations and would like to thank you for your efforts to maintain your property and to help preserve the safety and beauty of our community. If you have questions, please contact the undersigned Officer at (805) 783-7872 or nbuckley@slocity.org. Sincerely, ____________________________ Nick Buckley, Code Enforcement Officer Cc: Enclosures: Request for Directors Review 1 From:SLO <noreply@user.govoutreach.com> Sent:Thursday, April 6, 2023 2:54 PM To:Mezzapesa, John Subject:Ask SLO Notification of new Request #: 1854 This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Request # 1854 from the Government Outreach System has been assigned to Code Enforcement. Request type: Problem Request area: Unpermitted Construction (Completed) Citizen name: Anonymous Description: The owner has constructed a massive concrete retaining wall to extend the front yard. I don’t believe they have a permit for this. Location: 163 Serrano Heights, San Luis Obispo Expected Close Date: April 8, 2023 Click here to access the request Note: This message is for notification purposes only. Please do not reply to this email. Email replies are not monitored and will be ignored. 1 From:SLO <noreply@user.govoutreach.com> Sent:Thursday, April 6, 2023 2:54 PM To:Code Enforcement Subject:Ask SLO You have been assigned a new Request #: 1854 This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Request # 1854 from the Government Outreach System has been assigned to you. Request type: Problem Request area: Unpermitted Construction (Completed) Citizen name: Anonymous Description: The owner has constructed a massive concrete retaining wall to extend the front yard. I don’t believe they have a permit for this. Location: 163 Serrano Heights, San Luis Obispo To help protect your privacy, Microsoft Office prevented automatic download of this picture from the Internet. Expected Close Date: April 8, 2023 Click here to access the request Note: This message is for notification purposes only. Please do not reply to this email. Email replies are not monitored and will be ignored. 1 From:John Rourke < Sent:Monday, February 5, 2024 9:45 AM To:Loew, Michael; Mike Rourke Cc:Danielle Lauinger; Scott Stokes Subject:Re: 163 Serrano heights subdivision improvement map Attachments:image003.png Thanks Michael, Sorry for the confusion. John On Mon, Feb 5, 2024, 9:44 AM Loew, Michael <Mloew@slocity.org> wrote: Hi John, Your case can be found here: https://infoslo.slocity.org/energov_prod/selfservice#/plan/e7c4fe88-fadd- 4435-9454-801c8319dc42 This link will take you directly to your case if you are already logged in. Another way to navigate to your case would be through “My Work.” You should be able to find application number PLREV-0587-2023 under “My Plans” Once you go into the application (link above), click on the oval attachment tab and you should be prompted to submit project plans. Please also add any other documents such as comment responses. Feel free to reach out to me with any questions. Thank you, Michael Loew Deputy Director/Chief Building Official 2 The linked image cannot be displayed. The file may have been moved, renamed, or deleted. Verify that the link points to the correct file and location. Community Development E Mloew@slocity.org T 805.781.7157 slocity.org Stay connected with the City by signing up for e-notifications From: John Rourke < Sent: Wednesday, January 24, 2024 2:39 PM To: Loew, Michael <Mloew@slocity.org> Cc: Danielle Lauinger <dlauinger@abovegradeengineering.com>; Scott Stokes <scott@abovegradeengineering.com> Subject: Re: 163 Serrano heights subdivision improvement map Hi Michael, We already submitted one, this is the responses to your response. Does it go through the portal? Does it just get emailed? If so to who? Thanks John On Wed, Jan 24, 2024, 1:22 PM Loew, Michael <Mloew@slocity.org> wrote: Please work with the building counter to submit a permit revision application. You can follow the attached guide to submit online. Thank you, Michael Loew Deputy Director/Chief Building Official Community Development E Mloew@slocity.org T 805.781.7157 slocity.org Stay connected with the City by signing up for e-notifications 3 From: Danielle Lauinger <dlauinger@abovegradeengineering.com> Sent: Wednesday, January 24, 2024 9:02 AM To: Loew, Michael <Mloew@slocity.org> Cc: John Rourke < ; Scott Stokes <scott@abovegradeengineering.com> Subject: Re: 163 Serrano heights subdivision improvement map Michael, Attached is the revised plans with the retaining wall and its subdrain system. Please let me know if we need to submit these via another avenue. Thanks, On Mon, Nov 6, 2023 at 8:06 PM Loew, Michael <Mloew@slocity.org> wrote: Hi John, There isn’t a set of plans attached to this email. Is related to specific building permit? Michael Loew Deputy Director/Chief Building Official Community Development E Mloew@slocity.org T 805.781.7157 slocity.org Stay connected with the City by signing up for e-notifications From: John Rourke < Sent: Monday, November 6, 2023 9:46 AM To: Loew, Michael <Mloew@slocity.org> Cc: Scott Stokes <scott@abovegradeengineering.com>; Danielle Lauinger <dlauinger@abovegradeengineering.com> Subject: Re: 163 Serrano heights subdivision improvement map 4 Hi Michael, Here is the updated improvement map let me know if you need anything else. Thanks John On Mon, Nov 6, 2023, 9:20 AM Danielle Lauinger <dlauinger@abovegradeengineering.com> wrote: Sorry about that John. Here you go. On Mon, Nov 6, 2023 at 9:03 AM John Rourke < wrote: That is a county form, can you change to a city form On Mon, Nov 6, 2023, 8:33 AM Danielle Lauinger <dlauinger@abovegradeengineering.com> wrote: John, See attached revised plan set and the Change to Issued Permit form that you can submit to the City. On Wed, Nov 1, 2023 at 11:59 AM LaFreniere, Matt <mlafreni@slocity.org> wrote: Hi John, If there is proposed work on private property, please submit through the Building Division. Please reference the attached conditions, specifically: 10.A separate subdivision improvement or miscellaneous public improvement plan is not required. The building plan submittal may be used to show some or all of the required 5 private on-site subdivision improvements. Improvements located within the public right- of-way will require a separate encroachment permit and associated inspection fees based on the fee schedule in effect at the time of permit issuance, if applicable. A separate subdivision improvement plan review fee and subdivision map check fee will be required for the Public Works Department review and inspection of the public subdivision/development improvements and map in accordance with the most current fee resolution. Thank you, Matt LaFreniere pronouns he/him/his Engineering Technician III Community Development Engineering Development Review 919 Palm Street, San Luis Obispo, CA 93401-3218 E mlafreni@slocity.org T 805.781.7015 slocity.org Stay connected with the City by signing up for e-notifications From: John Rourke < Sent: Wednesday, November 1, 2023 11:34 AM To: Loew, Michael <Mloew@slocity.org>; LaFreniere, Matt <mlafreni@slocity.org>; Danielle Lauinger <dlauinger@abovegradeengineering.com> Subject: 163 Serrano heights subdivision improvement map This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Hi Michael and Matt, Danielle is finalizing the update to the map to reflect the retaining wall and fence.to who and how does she submit it? Thanks John 6 -- Danielle Lauinger, PE Civil Engineer Main: (805) 540-5115 | Direct: (805) 548-1181 245 Higuera Street, San Luis Obispo, CA 93401 -- Danielle Lauinger, PE Civil Engineer Main: (805) 540-5115 | Direct: (805) 548-1181 245 Higuera Street, San Luis Obispo, CA 93401 -- 7 Danielle Lauinger, PE Civil Engineer Main: (805) 540-5115 | Direct: (805) 548-1181 245 Higuera Street, San Luis Obispo, CA 93401 1 From:La Chaine, Steve Sent:Friday, November 17, 2023 12:03 PM To:Stong, Nate Subject:RE: ENCR-2031-2022 There is this ENCR permit, but no files attached, may have been for retaining wall hƩps://energov.slocity.org/energov_prod/managepermit/ - /permit/1f10a075-2156-40ab-a77e-07997d60538d/files From: La Chaine, Steve Sent: Friday, November 17, 2023 11:07 AM To: Stong, Nate <NStong@slocity.org> Subject: SBDV-2029-2018 (163 Serrano Heights) Tentative Parcel Map hƩps://energov.slocity.org/energov_prod/manageplan/ - /plan/cfc58830-cfe6-4ce2-bb50-2490f352de3d/files On work doc attached, #16 looks like Fire required FH there. Steve Steve La Chaine Engineering Consultant Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 E slachain@slocity.org T 805.781.7201 slocity.org Stay connected with the City by signing up for e-notifications 1 From:DeGiovanni, Stephanie Sent:Wednesday, November 1, 2023 12:42 PM To:LaFreniere, Matt Subject:RE: 163 Serrano heights subdivision improvement map Oh ok great! Thanks! From: LaFreniere, Matt <mlafreni@slocity.org> Sent: Wednesday, November 1, 2023 12:01 PM To: DeGiovanni, Stephanie <sdegiova@slocity.org> Subject: FW: 163 Serrano heights subdivision improvement map FYI, for reference. The Conditions of Approval should be a guide on how the project is submitted and what the requirements are. From: LaFreniere, Matt Sent: Wednesday, November 1, 2023 12:00 PM To: John Rourke < ; Loew, Michael <Mloew@slocity.org>; Danielle Lauinger <dlauinger@abovegradeengineering.com> Subject: RE: 163 Serrano heights subdivision improvement map Hi John, If there is proposed work on private property, please submit through the Building Division. Please reference the attached conditions, specifically: 10.A separate subdivision improvement or miscellaneous public improvement plan is not required. The building plan submittal may be used to show some or all of the required private on-site subdivision improvements. Improvements located within the public right-of-way will require a separate encroachment permit and associated inspection fees based on the fee schedule in effect at the time of permit issuance, if applicable. A separate subdivision improvement plan review fee and subdivision map check fee will be required for the Public Works Department review and inspection of the public subdivision/development improvements and map in accordance with the most current fee resolution. Thank you, Matt LaFreniere pronouns he/him/his Engineering Technician III 2 Community Development Engineering Development Review 919 Palm Street, San Luis Obispo, CA 93401-3218 E mlafreni@slocity.org T 805.781.7015 slocity.org Stay connected with the City by signing up for e-notifications From: John Rourke < Sent: Wednesday, November 1, 2023 11:34 AM To: Loew, Michael <Mloew@slocity.org>; LaFreniere, Matt <mlafreni@slocity.org>; Danielle Lauinger <dlauinger@abovegradeengineering.com> Subject: 163 Serrano heights subdivision improvement map This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Hi Michael and Matt, Danielle is finalizing the update to the map to reflect the retaining wall and fence.to who and how does she submit it? Thanks John CODE CASE ACTIVITY REPORT CODE-000063-2023 FOR CITY OF SAN LUIS OBISPO Address:Closed Date:In ViolationStatus:163 Serrano Heights San Luis Obispo, CA 93405 04/10/2023Opened Date:Nick BuckleyAssigned ToCode EnforcementCase Type: Activity Date Created By Activity Type CommentsActivity Name 04/10/2023 NB - Confirmed a retaining wall with a fence on top on site that appears to be new. Have not yet confirmed that the retaining wall was done without permit or in violation of building code. InspectionNick Buckley 4/10/23 NB - Received a complaint regarding a retaining wall with out permit. CorrespondenceNick Buckley 4/10/23 - Initial Complaint 04/19/2023 4/19/23 NB - Received a call from an anonymous reporting party regarding drainage that was installed which is causing erosion issues on neighbors The RP also stated that was going to call Jim Gorter to discuss. CorrespondenceNick Buckley Anon RP 05/03/2023 NB - Spoke with the property owner who was confident they did not need a permit because the fence was under 9 feet. He also denied my request for an onsite inspection. CorrespondenceNick Buckley 5-2-23 - PO 05/12/2023 NB - Building code states that any fence over 7 feet requires a permit and the municipal code amended that to 6 feet. Also, any retaining wall over 48 inches including the footing requires a permit. The retaining wall on site is at minimum 56 inches at highest point from natural grade determined by counting blocks. Permit is required for the retaining wall/fence. ResearchNick Buckley 5/3/23 NB - NOV sent certified and regular mail. Compliance due date is 6/12/23. Notice of ViolationNick Buckley 5/12/23 06/25/2024 NB - Multiple emails exchanged between the property owner, building staff, engineering staff and myself. I also had a phone conversation with the property owner today where we discussed the height of the wall, and the footings. The property owner states that there is a difference in opinion regarding what constitutes a footing. My response is that a retaining wall will be measured from the bottom of the concrete or block (including what is below grade) to the bottom of the concrete or block. I also sent the PO an email with the original NOV attached. A permit tech also sent him the comments from engineering yesterday and again today. CorrespondenceNick Buckley 6/25/24 Page 1 of 1City of San Luis ObispoJune 26, 2024 Notice to Correct Code Violation(s)/Notice of Violation (Courtesy Warning Prior to Issuance of Administrative Citation) May 12, 2023 John Rourke 281 Broad St San Luis Obispo, CA 93405 SUBJECT ADDRESS: 163 Serrano Heights, San Luis Obispo, CA 93405 APN: 052-061-049 Code Case #: CODE-000063-2023 Dear Property Owner, On April 10th, 2023, City of San Luis Obispo Community Development Department staff noted the following violations of the San Luis Obispo Municipal Code or other relevant codes at the above listed address: 1. Permit Required (SLOMC 15.02.020, California Building Code 105.1) “Any owner or owner’s authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the building official and obtain the required permit.” Resolution: Permit or remove the retaining wall/fence combination. 2. Fences, Walls, and Hedges (SLOMC 17.70.070[C]) “Fences, walls or hedges may be placed within required yards, provided they do not exceed maximum height limitations and comply with the following standards: 1. The maximum height of a fence, wall, or hedge shall not exceed six feet; except within any front setback, the maximum fence, wall, or hedge shall be as shown in Figure 3-3. Corrective Action: Reduce the fence height to the allowed fence height according to the fence height standards. Or obtain building permit. ALL REQUIRED WORK MUST BE COMPLETED WITHIN 90 DAYS OF PERMIT ISSUANCE. We request that you voluntarily take action to correct the above noted violation(s) no later than 6/12/2022. These violations constitute a public nuisance and must be abated. Failure to correct the violation(s) by the specified date will result in the issuance of an Administrative Citation requiring payment of FINES in accordance with SLOMC Chapter 1.24. For Municipal Code violations that remain uncorrected after issuance of an Administrative Citation, the City may seek enforcement by other civil or criminal remedies. Any person having a title interest in the property may request a Director’s review of this Notice by completing the enclosed Request for Director’s Review Form and submitting it to the Community Development Department via email at code@slocity.org or to 919 Palm Street, San Luis Obispo, CA 93401, within five (5) days of the date of this Notice. This Notice shall be deemed final unless you timely file a Request for Director’s Review. We look forward to working with you to resolve these violations and would like to thank you for your efforts to maintain your property and to help preserve the safety and beauty of our community. If you have questions, please contact the undersigned Officer at (805) 783-7872 or nbuckley@slocity.org. Sincerely, ____________________________ Nick Buckley, Code Enforcement Officer Cc: Enclosures: Request for Directors Review Notice to Correct Code Violation(s)/Notice of Violation (Courtesy Warning Prior to Issuance of Administrative Citation) May 12, 2023 John Rourke 281 Broad St San Luis Obispo, CA 93405 SUBJECT ADDRESS: 163 Serrano Heights, San Luis Obispo, CA 93405 APN: 052-061-049 Code Case #: CODE-000063-2023 Dear Property Owner, On April 10th, 2023, City of San Luis Obispo Community Development Department staff noted the following violations of the San Luis Obispo Municipal Code or other relevant codes at the above listed address: 1. Permit Required (SLOMC 15.02.020, California Building Code 105.1) “Any owner or owner’s authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the building official and obtain the required permit.” Resolution: Permit or remove the retaining wall/fence combination. 2. Fences, Walls, and Hedges (SLOMC 17.70.070[C]) “Fences, walls or hedges may be placed within required yards, provided they do not exceed maximum height limitations and comply with the following standards: 1. The maximum height of a fence, wall, or hedge shall not exceed six feet; except within any front setback, the maximum fence, wall, or hedge shall be as shown in Figure 3-3. Corrective Action: Reduce the fence height to the allowed fence height according to the fence height standards. Or obtain building permit. ALL REQUIRED WORK MUST BE COMPLETED WITHIN 90 DAYS OF PERMIT ISSUANCE. We request that you voluntarily take action to correct the above noted violation(s) no later than 6/12/2022. These violations constitute a public nuisance and must be abated. Failure to correct the violation(s) by the specified date will result in the issuance of an Administrative Citation requiring payment of FINES in accordance with SLOMC Chapter 1.24. For Municipal Code violations that remain uncorrected after issuance of an Administrative Citation, the City may seek enforcement by other civil or criminal remedies. Any person having a title interest in the property may request a Director’s review of this Notice by completing the enclosed Request for Director’s Review Form and submitting it to the Community Development Department via email at code@slocity.org or to 919 Palm Street, San Luis Obispo, CA 93401, within five (5) days of the date of this Notice. This Notice shall be deemed final unless you timely file a Request for Director’s Review. We look forward to working with you to resolve these violations and would like to thank you for your efforts to maintain your property and to help preserve the safety and beauty of our community. If you have questions, please contact the undersigned Officer at (805) 783-7872 or nbuckley@slocity.org. Sincerely, ____________________________ Nick Buckley, Code Enforcement Officer Cc: Enclosures: Request for Directors Review Request: 1854 Entered on: 04/06/2023 2:53 PM Customer Information Name:Anonymous Phone: Address:Alt. Phone: ,Email: Request Classification Topic:Unpermitted Construction (Completed)Request type:Problem Status:Closed Priority:Normal Assigned to:Nick Buckley Entered Via:iPhone Problem Location:163 Serrano Heights, San Luis Obispo BCC Council? Days to Close 4 Disposition Code Case Created Description The owner has constructed a massive concrete retaining wall to extend the front yard. I don’t believe they have a permit for this. Reason Closed There are building permtis issued but they do not identify retaining walls. Will set up inspection with T. Nelson and property owner. Date Expect Closed: 04/08/2023 Date Closed: 04/10/2023 3:13 PM By: Nick Buckley Enter Field Notes Below Notes: 6/26/24, 3:51 PM Print Request https://user.govoutreach.com/sanluisobispoca/printrequest.php?curid=6839166&type=0 1/2 Notes Taken By: Date: 6/26/24, 3:51 PM Print Request https://user.govoutreach.com/sanluisobispoca/printrequest.php?curid=6839166&type=0 2/2