HomeMy WebLinkAbout08-26-2024 TC Agenda Packet
Tree Committee
AGENDA
Monday, August 26, 2024, 5:30 p.m.
Council Hearing Room, 990 Palm Street, San Luis Obispo
The Tree Committee holds in-person meetings. Zoom participation will not be supported at this time.
Attendees of City Council or Advisory Body meetings are eligible to receive one hour of
complimentary parking; restrictions apply, visit Parking for Public Meetings for more details.
INSTRUCTIONS FOR PUBLIC COMMENT:
Public Comment prior to the meeting (must be received 3 hours in advance of the meeting):
Mail - Delivered by the U.S. Postal Service. Address letters to the City Clerk's Office at 990
Palm Street, San Luis Obispo, California, 93401.
Email - Submit Public Comments via email to advisorybodies@slocity.org. In the body of your
email, please include the date of the meeting and the item number (if applicable). Emails will not
be read aloud during the meeting.
Voicemail - Call (805) 781-7164 and leave a voicemail. Please state and spell your name, the
agenda item number you are calling about, and leave your comment. Verbal comments must be
limited to 3 minutes. Voicemails will not be played during the meeting.
*All correspondence will be archived and distributed to members, however, submissions received
after the deadline ma not be processed until the following day.
Public Comment during the meeting:
Meetings are held in-person. To provide public comment during the meeting, you must be
present at the meeting location.
Electronic Visual Aid Presentation. To conform with the City's Network Access and Use Policy,
Chapter 1.3.8 of the Council Policies & Procedures Manual, members of the public who desire
to utilize electronic visual aids to supplement their oral presentation must provide display-ready
material to the City Clerk by 12:00 p.m. on the day of the meeting. Contact the City Clerk's
Office at cityclerk@slocity.org or (805) 781-7114.
Pages
1.CALL TO ORDER
Chair Elizabeth Lucas will call the Regular Meeting of the Tree Committee to
order.
2.PUBLIC COMMENT FOR ITEMS NOT ON THE AGENDA
The public is encouraged to submit comments on any subject within the
jurisdiction of the Tree Committee that does not appear on this agenda.
Although the Committee will not take action on items presented during the
Public Comment Period, the Chair may direct staff to place an item on a future
agenda for discussion.
3.CONSENT
Matters appearing on the Consent Calendar are expected to be non-
controversial and will be acted upon at one time. A member of the public may
request the Tree Committee to pull an item for discussion. The public may
comment on any and all items on the Consent Agenda within the three-minute
time limit.
3.a CONSIDERATION OF MINUTES - JUNE 24, 2024 AND JULY 22, 2024
TREE COMMITTEE MINUTES
5
Recommendation:
To approve the following Tree Committee Minutes:
June 24, 2024•
July 22, 2024•
4.TREE REMOVAL APPLICATION
4.a REVIEW A TREE REMOVAL APPLICATION TO REMOVE ONE
SWEETGUM (LIQUIDAMBAR STYRACIFLUA) TREE LOCATED AT
470 PISMO STREET (TREE-0221-2024)
13
Recommendation:
Review the proposed Tree Removal Application (TREE-0221-2024) to
remove one (1) Sweetgum (Liquidambar styraciflua) tree for consistency
with the Municipal Code Section 12.24.090(E) Criteria and Process for
Non-Construction Related Tree Removal Application Determinations
Related to Property Owner Convenience and provide a
recommendation to the Community Development Director.
5.NEW BUSINESS
5.a REVIEW LAGUNA LAKE DOG PARK REVITALIZATION PROJECT
REPLANTING PLAN (TREE-0344-2024)
23
Recommendation:
Review the Laguna Lake Dog Park Revitalization Planting Plan and
provide recommendations for species selections based on the
information provided in the plans and characteristics specific to the site.
6.COMMENT AND DISCUSSION
6.a ARBORIST REPORT
Receive a brief update from Urban Forest Program Coordinator / City
Arborist Walter Gault.
7.ADJOURNMENT
The next Regular Meeting of the Tree Committee meeting is scheduled for
September 23, 2024 at 5:30 p.m. in the Council Hearing Room at City Hall, 990
Palm Street, San Luis Obispo.
LISTENING ASSISTIVE DEVICES are available -- see the Clerk
The City of San Luis Obispo wishes to make all of its public meetings accessible
to the public. Upon request, this agenda will be made available in appropriate
alternative formats to persons with disabilities. Any person with a disability who
requires a modification or accommodation in order to participate in a meeting
should direct such request to the City Clerk’s Office at (805) 781-7114 at least
48 hours before the meeting, if possible. Telecommunications Device for the
Deaf (805) 781-7410.
Agenda related writings or documents provided to the Tree Committee are
available for public inspection on the City’s website:
https://www.slocity.org/government/mayor-and-city-council/agendas-and-
minutes. Meeting video recordings can be found on the City’s website:
http://opengov.slocity.org/WebLink/Browse.aspx?id=61087&dbid=0&repo=CityCl
erk
1
Tree Committee Minutes
June 24, 2024, 5:30 p.m.
Council Hearing Room, 990 Palm Street, San Luis Obispo
Tree Committee
Members Present:
Member Alan Bate, Member Henry Bonifas, Member Daniel
Canella, Member Brian Pineda, Member Emily Rosten, Vice
Chair Ben Parker, Chair Elizabeth Lucas
City Staff Present: Urban Forest Program Coordinator / City Arborist Walter Gault,
Senior Planner Rachel Cohen, City Clerk Teresa Purrington
_____________________________________________________________________
1. CALL TO ORDER
A Regular Meeting of the San Luis Obispo Tree Committee was called to order
on June 24, 2024 at 5:33 p.m. in the Council Hearing Room at City Hall, 990
Palm Street, San Luis Obispo, by Chair Lucas with all members present.
2. PUBLIC COMMENT FOR ITEMS NOT ON THE AGENDA
Public Comment:
None
--End of Public Comment--
3. CONSENT
3.a CONSIDERATION OF MINUTES - MAY 20, 2024 TREE COMMITTEE
MINUTES
Motion By Vice Chair Parker
Second By Member Rosten
To approve the Tree Committee Minutes of May 20, 202 4.
Ayes (7): Member Bate, Member Bonifas, Member Canella, Member
Pineda, Member Rosten, Vice Chair Parker, and Chair Lucas
CARRIED (7 to 0)
Page 5 of 57
2
4. TREE REMOVAL APPEALS
4.a REVIEW A TREE REMOVAL APPEAL OF THE CITY ARBORIST’S
DECISION TO DENY REMOVAL OF TWO (2) SHAMEL ASH (FRAXINUS
UHDEI) TREES LOCATED AT 2125 STORY STREET, IN THE PARKWAY
NEAR CORNER OF SANDERCOCK AND STORY
City Arborist Walter Gault presented the staff report and responded to
Committee inquiries.
Appellant representative, Sam Oakley, provided an overview of the Tree
Removal Appeal and responded to questions raised.
Chair Lucas opened Public Comment
Public Comment:
None
--End of Public Comment--
Chair Lucas closed Public Comment
Motion By Member Canella
Second By Member Rosten
To approve the removal of two (2) Shamel Ash (Fraxinus uhdei) trees
consistent with Section 12.24.090 (E)(1)(d) and (f) of the Municipal Code,
with the following conditions:
A replanting plan shall be submitted prior to removal of the two
trees.
Two (2) 24-inch box trees with a minimum height of 25 feet shall be
planted in the same location. Recommend using structural soil and
significant tree protection around the trees.
An additional four trees with a minimum height of 35 feet shall be
planted at a location of the applicant's choosing on the school
property.
Ayes (7): Member Bate, Member Bonifas, Member Canella, Member
Pineda, Member Rosten, Vice Chair Parker, and Chair Lucas
CARRIED (7 to 0)
Page 6 of 57
3
5. TREE REMOVAL APPLICATION
5.a REVIEW A TREE REMOVAL CONVENIENCE APPLICATION TO
REMOVE ONE (1) LONDON PLANE TREE (PLANTANUS X
ACERFOLIA) (HISPANICA) LOCATED AT 4275 POINSETTIA STREET
Vice Chair Parker declared a conflict with this item and recused as he lives
within the boundary, and serves as a Board Member, of the Sa nta Lucia
Hills Homeowners Association.
City Arborist Walter Gault presented the staff report and responded to
Committee inquiries.
Applicant, Luann Cheda, provided an overview of the Tree Removal
Application and responded to questions raised.
Chair Lucas opened Public Comment
Public Comment:
None
--End of Public Comment--
Chair Lucas closed Public Comment
Motion By Member Bate
Second By Member Pineda
To recommend the Community Development Director approve the Tree
Removal Application to remove one (1) London Plane (Platanus X
hispanica) tree. The Committee finds the removal consistent with Section
12.24.090 (G) (5) and (6), per the landscape plan submitted, with the
added recommendation that drought tolerant native trees be planted.
Ayes (4): Member Bate, Member Canella, Member Rosten, and Chair
Lucas
Noes (2): Member Bonifas, and Member Pineda
Recused (1): Vice Chair Parker
CARRIED (4 to 2)
Page 7 of 57
4
6. COMMENT AND DISCUSSION
6.a ARBORIST REPORT
Urban Forest Program Coordinator / City Arborist Walter Gault provided an
update of upcoming projects and activities related to the City’s urban
forest.
7. ADJOURNMENT
The meeting was adjourned at 7:18 p.m. The next Regular Meeting of the Tree
Committee is scheduled for July 22, 2024 at 5:30 p.m. in the Council Hearing
Room at City Hall, 990 Palm Street, San Luis Obispo.
APPROVED BY TREE COMMITTEE: XX/XX/2024
Page 8 of 57
1
Tree Committee Minutes
July 22, 2024, 5:30 p.m.
Council Hearing Room, 990 Palm Street, San Luis Obispo
Tree Committee
Members Present:
Member Daniel Canella, Member Emily Rosten, Chair Elizabeth
Lucas
Tree Committee
Members Absent:
Member Alan Bate, Member Henry Bonifas, Member Brian
Pineda, Vice Chair Ben Parker
City Staff Present: Urban Forest Program Coordinator / City Arborist Walter Gault,
Senior Planner Rachel Cohen, Deputy City Clerk Megan Wilbanks
_____________________________________________________________________
1. CALL TO ORDER
A Regular Meeting of the San Luis Obispo Tree Committee was called to order
on July 22, 2024 at 5:30 p.m. in the Council Hearing Room at City Hall, 990 Palm
Street, San Luis Obispo, by Chair Lucas.
2. PUBLIC COMMENT FOR ITEMS NOT ON THE AGENDA
Public Comment:
None
--End of Public Comment--
3. CONSENT
3.a CONSIDERATION OF MINUTES - JUNE 24, 2024 TREE COMMITTEE
MINUTES
As a quorum was not present, consideration of the June 24, 2024 Tree
Committee Draft Minutes was continued to the next Regular Meeting,
August 26, 2024.
Page 9 of 57
2
4. NEW BUSINESS
4.a REVIEW OF LAGUNA LAKE DOG PARK REVITALIZATION PROJECT
REPLANTING PLAN (TREE-0344-2024)
Urban Forest Program Coordinator / City Arborist Walter Gault provided a
brief informational presentation.
Chair Lucas opened Public Comment
Public Comment:
Hugh O'Malley
--End of Public Comment--
Chair Lucas closed Public Comment
As a quorum was not present, consideration of this item was continued to
the next Regular Meeting, August 26, 2024.
5. COMMENT AND DISCUSSION
5.a ARBORIST REPORT
Urban Forest Program Coordinator / City Arborist Walter Gault provided
the following update of activities in the Tree Division:
Additional street trees will be planted in the parkway at the corner
of Lawrence Drive and Broad Street.
Staff continues to try to meet with the property owner at 1250 Palm
Street, where one palm tree was removed, to ensure four (4)
replacement trees are planted on the site, as recommended by the
Tree Committee at their September 25, 2023 meeting.
Staff continues to work with the tenant at 1065 Higuera Street,
where four (4) palm trees were removed, to identify appropriate
locations on the site to plant four (4) replacement trees, as
recommended by the Tree Committee at their March 25, 2024
meeting.
Staff is actively working to ensure the administrative and noticing
process is complete in order to recover fines levied on the property
owner of 163 Serrano Heights Drive, as approved by the Tree
Committee at their February 12, 2024 meeting.
Page 10 of 57
3
6. ADJOURNMENT
The meeting was adjourned at 5:46 p.m. The next Regular Meeting of the Tree
Committee is scheduled for August 26, 2024 at 5:30 p.m. in the Council Hearing
Room at City Hall, 990 Palm Street, San Luis Obispo.
_________________________
APPROVED BY TREE COMMITTEE: XX/XX/2024
Page 11 of 57
Page 12 of 57
TREE COMMITTEE AGENDA REPORT
SUBJECT: REVIEW A TREE REMOVAL APPLICATION TO REMOVE ONE
SWEETGUM (LIQUIDAMBAR STYRACIFLUA) TREE LOCATED AT 470 PISMO
STREET
FILE NUMBER: TREE-0221-2024 PROJECT ADDRESS: 470 Pismo Street
FROM: Walter Gault, Urban Forestry Program Coordinator / City Arborist
Phone Number: (805) 781-7578
Email: wgault@slocity.org
RECOMMENDATION
Review the proposed Tree Removal Application (TREE-0221-2024) to remove one (1)
Sweetgum (Liquidambar styraciflua) tree for consistency with the Municipal Code Section
12.24.090(E) Criteria and Process for Non -Construction Related Tree Removal
Application Determinations Related to Property Owner Convenience and provide a
recommendation to the Community Development Director.
1.0 APPLICATION DESCRIPTION
RongShan Jin (Applicant) has requested the removal of one (1) Liquidambar styraciflua
in the front yard at 470 Pismo Street per Municipal Code Section 12.24.090(E) related to
property owner convenience. The applicant would like to remove the tree and replace it
with 3 trees (2 Jacaranda mimisifolia and 1 Cercis occidentalis [Western Redbud]).
Meeting Date: 8/26/2024
Item Number: 4a
Time Estimate: 20 Minutes
Figure 1: Location of the proposed tree removal at 470
Pismo Street.
Figure 2: View of the
Liquidambar styraciflua in
the front yard.
Page 13 of 57
Item 4a
TREE-0221-2024 (470 Pismo St.)
Tree Committee Report – August 26, 2024
2.0 COMMITTEE PURVIEW
The Tree Committee’s role is to review the removal request in accordance with the
process set forth in San Luis Obispo Municipal Code (SLOMC) Section 12.24 (Tree
Municipal Code Section 12.24.090(E)(3). This code section utilizes the process set forth
in subsection F(2), the relevant additional application requirements in subsection (D)(2)
and the criteria set forth in subsection (G).
3.0 TREE REGULATIONS
The City’s Tree Ordinance (Municipal Code Chapter 12.24) was adopted in 2010 and
recently updated in 2019 with the purpose of establishing a comprehensive program for
installing, maintaining, and preserving trees within the City. This ordinance establishes
policies, regulations, and specifications necessary to govern installation, maintenance,
removal, and preservation of trees to beautify the city; to purify the air; to provide shade
and wind protection; to add environmental and economic value; and to preserve trees
with historic or unusual value.
Criteria for Convenience Tree Removal Applications.
SLOMC §12.24.090 subsection (E)(3) requires review by the Tree Committee using the
criteria set for in SLOMC §12.24.090(G). Staff has provided the applicable criteria below
that applies to this application as well as a brief discussion . The Tree Committee should
discuss whether the proposed tree removal is consistent with the code.
(G)(1). Size of Tree. The scale of the tree shall be considered, as well as the size
of the tree’s canopy. Larger, more visually prominent trees may have a higher
preservation priority than smaller, less visually prominent trees. The tree proposed
for removal is large and visually prominent in the front yard of the site.
(G)(2). Location of Tree on Private Property. The location of the tree on private
property shall be considered. Trees located in a private rear yard, which are not
highly visible from the public right-of-way, may have a lower preservation priority
than trees with a high visual impact to the neighborhood. The tree proposed for
removal is located in the front yard and is highly visible from the public right of way.
(G)(3). Species of Tree. Native trees shall have a higher preservation priority than
non-native trees. The tree proposed for removal is not native.
(G)(6). Compliance with Subsection J of This Section Regarding Compensatory
Plantings. The approving authority may consider an application proposal to provide
compensatory plantings in excess of required minimums in evaluating this
criterion. The applicant is proposing to replant three trees in place of the one tree
removal.
Page 14 of 57
Item 4a
TREE-0221-2024 (470 Pismo St.)
Tree Committee Report – August 26, 2024
4.0 ACTIONS
4.1 Recommend findings of consistency with the Tree Regulations. An action
recommending approval of the application based on consistency with the Tree
Regulations (SLOMC Section 12.24). An approval of the application should
include a compensatory replanting plan with size and species of tree.
4.2 Recommend findings of inconsistency with the Tree Regulations. An action
recommending denial of the application should include findings that cite the
basis for denial and should reference inconsistency with the General Plan, Tree
Regulations, or other policy documents.
4.3 Continue the project to a hearing date certain, or uncertain. An action
continuing the application should include direction to the applicant and staff on
pertinent issues.
5.0 ATTACHMENTS
A - Tree Removal Application for 470 Pismo (TREE-0221-2024)
Page 15 of 57
Page 16 of 57
Page 17 of 57
Page 18 of 57
Page 19 of 57
Page 20 of 57
Page 21 of 57
Page 22 of 57
TREE COMMITTEE AGENDA REPORT
SUBJECT: LAGUNA LAKE DOG PARK REVITALIZATION PROJECT
FILE NUMBER: TREE-0344-2024 FROM: Walter Gault, City Arborist
PROJECT ADDRESS: 504 Madonna Rd. Phone Number: (805) 781-7578
APPLICANT: City of San Luis Obispo Email: wgault@slocity.org
RECOMMENDATION
Review the Laguna Lake Dog Park Revitalization Planting Plan and provide
recommendations for species selections based on the information provided in the plans
and characteristics specific to the site.
1.0 COMMITTEE PURVIEW
The Tree Committee’s role is to review the planting plan and the site at Laguna Lake Park
and provide recommendations for species selections based on the information provided
in the plans and characteristics specific to the site.
2.0 PROJECT DESCRIPTION
City of San Luis Obispo Public Works Department (Applicant) has been approved to
remove two trees as part of the Laguna Lake Dog Park Revitalization Project and replant
a minimum of 6 trees. The applicant has developed a draft landscape plan that shows the
planting of 38 new trees (see Attachment A, pages 25 and 26).
Meeting Date: 8/26/2024
Item Number: 5a
Time Estimate: 60 minutes
Figure 1: Proposed location of the Laguna Lake Dog Park
Page 23 of 57
Item 5a
TREE-0344-2024
Tree Committee Report – 8/26/2024
2.1 Existing Conditions
The Laguna Lake Open Space is one of the harsher microclimates in the city limits. While
generally cooler, it is also windier and drier. The soil transitions from a rocky outcrop to
Cropley clay in the flatter sections. The estimated frost-free period is 300 days, which is
about 15 days less than more protected areas closer to the city’s center.
The Cropley soil series consists of very deep, moderate to well-draining soils that formed
in alluvium from mixed rock sources. Cropley soils are on alluvial fans, floodplains and in
small basins.
Throughout the open space, eucalyptus and pine species appear to be performing well.
Eucalyptus are strong performers in dryer and harsher conditions. Oak tree species are
performing moderately well, and Camphor and cypress tree species are either stunted or
showing signs of stress. One Grevillea robusta (Silk Oak) tree, located south of the dog
park towards the lake, is performing fairly well.
2.2 Planting Plan
The project will be required to plant six (6) trees as a minimum compensatory replanting
for the removal of two (2) trees as a part of the project. As currently proposed, the
applicant has drafted a planting plan that includes a variety of trees, shrubs,
groundcovers, and other plants. The proposed 38 trees that are included in this planting
plan are predominantly native to California. As a part of the “shrub” planting schedule,
nine (9) 15-gallon toyons are to be planted. 18 manzanitas are functioning as ground
cover in addition to spreading rush and wild rye. Extent or existence of irrigation is still to
be determined.
Species for review.
The tree planting plan includes 5 different species: (8) Alnus Rhombifolia (White Alder),
(5) Cupressus macrocarpa (Monterey Cypress), (2) Platanus racemosa (California
sycamore), (10) Quercus agrifolia (Coast live oak) and (13) Chitalpa tashkentensis.
Species of highest focus are the alder, cypress and chitalpa. Staff is seeking Tree
Committee direction on whether these are the right tree species for this location
and based on the existing planting plan palette.
The alder is a riparian tree and has high water needs. While the water table is likely
high due to the presence of Laguna Lake, it is uncertain that the tree will benefit
from it due to the dog park’s distance from the lake.
Monterey cypress is relatively drought tolerant but only in cooler coastal conditions
where they can benefit from the marine layer. In dryer inland areas, cypress
perform better with more water. Existing cypress at Laguna Lake are not robust.
Page 24 of 57
Item 5a
TREE-0344-2024
Tree Committee Report – 8/26/2024
Chitalpa is supposed to be a tough drought tolerant tree, but it is also relatively
small. There are concerns about its performance in the cooler and harsher
environment at Laguna Lake. There is fair specimen that is currently flowering
located in the Mission Plaza seating area in between the San Luis Creek bridge
and Chorro Street. This location is wind-insulated, warmer and likely has more
access to water than the site at Laguna Lake Park.
Species substitutions to consider.
Eucalyptus at Laguna Lake are performing well. New species to consider:
Angophora costata (Sydney Red Gum), Corymbia ficifolia (Red Flowering Gum),
Eucalyptus cinerea (Argyle Apple), Eucalyptus spathulata (Swamp Mallet),
Eucalyptus erythrocorys (Red-Cap Gum), Eucalyptus torquata (Coral Gum)
Due to the predominantly California native planting pallet, consider substituting or
adding different oak species (oblongifolia, engelmannii, hypoleucoides, rugosa,
tomentella)
Other California natives for consideration: Lyonothamnus floribundus (Catalina
Ironwood)
Melaleuca quinquenervia (Paperbark/ Cajeput) is a low-water, drought tolerant
tree from Australia and underutilized in the City.
Other species recommendations welcome. SelecTree is a useful resource when
comparing species.
3.0 ACTIONS
3.1 Provide direction to staff supporting the existing planting plan.
3.2 Provide direction to staff on other tree species that should be considered
as a part of the planting plan.
4.0 ATTACHMENTS
A - Laguna Lake Dog Park Site Plan
Page 25 of 57
Page 26 of 57
/
//
/
/
/
/
/
/
/
//
/
/
/
/
/
/
/
//
••
••
••
••
•
•
•
•
•
•
•
•
•
•••
••
•
•
•
•
•
•
••
••
•
•
•
•
•
•
•
•
13
13
15
19
70
19
•
•
•
•
131313131311111313
•
•
•
•
•
•
•
•
••
12/21/2023
C-1.0 31
APPROVED BY
SPECIFICATION NO.
FILE NO./LOCATION
DATE
OF
SHEET
Reference Documents:
City Standard Specifications - August 2020 Edition
City Engineering Standards - August 2020 Edition
APPLICABLE CODES:
CALTRANS STANDARD PLANS - 2022
CBC - 2022 California Building Code
CPC - 2022 California Plumbing Code
GBC - 2022 Green Building Code
CFC - 2022 California Fire Code
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR PERMITTEE TO
CONTACT "UNDERGROUND SERVICE ALERT OF NORTHERN CALIFORNIA" BY
PHONE AT 8-1-1 TWO WORKING DAYS PRIOR TO START OF CONSTRUCTION
FOR LOCATION OF POWER, TELEPHONE, OIL AND NATURAL GAS
UNDERGROUND FACILITIES. CONTRACTOR OR PERMITEE SHALL ALSO
CONTACT THE APPROPRIATE AGENCY FOR THE LOCATION OF CABLE T.V.,
WATER, SEWER, DRAINAGE OR UNDERGROUND FACILITIES.
2. THE CONTRACTOR SHALL POSSESS A CLASS "A" LICENSE AT THE TIME OF THE
BID OPENING.
3. CONTRACTOR SHALL DETERMINE ALL UTILITY CONFLICTS AND SHALL
POTHOLE AND LOCATE PRIOR TO CONSTRUCTION, UTILITY LOCATION, DEPTH,
SIZE AND MATERIAL SHALL BE REPORTED TO THE ENGINEER, AS REQUIRED
BY THE SPECIAL PROVISIONS
4. EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED
DURING ALL CONSTRUCTION AND GROUND DISTURBING ACTIVITIES PER CITY
OF SAN LUIS OBISPO STANDARDS.
5. SEE APPENDIX [B] OF THE PROJECT SPECIAL PROVISIONS FOR THE
GEOTECHNICAL ENGINEERING REPORT "LAGUNA LAKE DOG PARK
IMPROVEMENTS, 504 MADONNA ROAD, SAN LUIS OBISPO, CALIFORNIA"
PREPARED ON AUGUST 4, 2023 FOR THE CITY OF SAN LUIS OBISPO
index to plans
Brian Nelson R.C.E. C 79870
City Engineer
general notes:
datum:
CONSULTANT NAME:
LAGUNA LAKE DOG
PARK IMPROVEMENTS
504 MADONNA ROAD
CONSTRUCTION MANAGEMENT
www.wallacegroup.us
MECHANICAL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEYING / GIS SOLUTIONS
WATER RESOURCES
PUBLIC WORKS ADMINISTRATION
PLANNING
CIVIL AND TRANSPORTATION ENGINEERING
••
1. SEE SHEET SC-1 FOR SURVEY DATUM INFORMATION.
2000526-01Scale: NTS
DOG PARK LOCATION MAP
ENGINEER OF RECORD:
scope of work:
WORK FOR THIS PLAYGROUND RENOVATION PROJECT INCLUDES:
1. REMOVAL OF THE EXISTING FENCE AND CMU WALLS, EXISTING LOG BARRIERS,
EXISTING CONCRETE, EXISTING BENCHES, AND EXISTING NON-ADA COMPLIANT PATH
OF TRAVEL.
2. INSTALLATION OF NEW SIDEWALK, RECREATION AREAS, SHADE EQUIPMENT, PAVERS,
PICNIC TABLES, BENCHES, FENCING, ADA PATH OF TRAVEL, ADA COMPLIANT RAMP, AND
WATER FOUNTAINS.
E
(SIGNATURE)
ANN SEVER
F
ST
OEAT A L IFC
R
S
REGI
ET LIC. #4038
AL N
E D PADSC
R NO IA
E
C
T
CH
AR
T
I
Sheet List Table
D
A
L
I
D
I
O
D
R
I
V
E
deferred submittals:
1. SHADE STRUCTURE STRUCTURAL DESIGN. SEE SPECIAL
PROVISIONS, SECTION 5-1.23B(3)
2. SWPPP
SCALE: NTS
Page 27 of 57
FILE NAME: 061-118 NOTE.DWG
GENERAL NOTES
1. THESE PLANS ARE PART OF A SET OF CONTRACT DOCUMENTS AND SHALL
NOT BE CONSIDERED THE SOLE SOURCE OF CONSTRUCTION INFORMATION.
ALL CONSTRUCTION WORK AND INSTALLATIONS SHALL CONFORM TO THE CITY
OF SAN LUIS OBISPO AND CALTRANS STANDARDS AND SPECIFICATIONS, THE
CONTRACT DOCUMENTS AND WORK SHALL BE SUBJECT TO THE APPROVAL OF
THE CITY OF SAN LUIS OBISPO PUBLIC WORKS DEPARTMENT.
2. THE CONTRACTOR SHALL HAVE COPIES OF THE APPROVED CONTRACT
DOCUMENTS FOR THIS PROJECT ON THE SITE AT ALL TIMES AND SHALL BE
FAMILIAR WITH ALL APPLICABLE STANDARDS AND SPECIFICATIONS.
3. CONTRACTOR AGREES THAT HE OR SHE SHALL ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR THE JOB SITE DURING THE COURSE OF THE
PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS
REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY,
AND HOLD THE ENGINEER AND OWNER HARMLESS FROM ANY AND ALL
LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF THE OWNER OR ENGINEER, OR THIRD PARTY IN VIOLATION OF
THE LAW OR IN TRESPASS. THE CONTRACTOR SHALL PRACTICE SAFETY AT
ALL TIMES AND SHALL FURNISH, ERECT, AND MAINTAIN, SUCH FENCES,
BARRICADES, LIGHTS, AND SIGNS NECESSARY TO GIVE ADEQUATE
PROTECTION TO THE PUBLIC AT ALL TIMES.
4. INFORMATION PERTAINING TO EXISTING UNDERGROUND FACILITIES IS
BASED ON RECORD INFORMATION AND IS SHOWN FOR INFORMATION
PURPOSES ONLY. UNDERGROUND FEATURES SHOWN IN PLAN VIEW ON THE
PLANS ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT,
AND MAY NOT APPEAR IN PROFILE OR SECTION VIEWS. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR CONTACTING ALL AGENCIES INVOLVED AND
SHALL LOCATE ALL FACILITIES PRIOR TO EXCAVATION IN ANY AREA. THE
CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (USA), TOLL FREE
AT 811 AND THE CITY OF SAN LUIS OBISPO FORTY-EIGHT (48) HOURS PRIOR TO
THE START OF CONSTRUCTION.
5. THE CONTRACTOR SHALL CONTINUALLY REVIEW JOB SITE CONDITIONS.
CONDITIONS REQUIRING CONSTRUCTION DIFFERENT FROM THAT SHOWN ON
THE PLANS SHALL BE REPORTED TO THE ENGINEER PRIOR TO PROCEEDING
WITH THE AFFECTED CONSTRUCTION.
6. THESE DRAWINGS REPRESENT THE FINISHED CONDITION AND UNLESS
OTHERWISE INDICATED, THEY DO NOT SHOW THE METHOD OF
CONSTRUCTION.
7. ALL IMPROVEMENTS SHOWN OR INDICATED ON THESE DRAWINGS ARE TO
BE CONSTRUCTED AND/OR INSTALLED BY THE CONTRACTOR ON THIS
PROJECT, UNLESS THEY ARE CALLED OUT AS: "EXISTING", "FUTURE", "NIC", NOT
A PART; OR HAVE SOME OTHER EXCLUDING NOTATION.
8. CONTRACTOR SHALL KEEP A SET OF PROJECT DRAWINGS ON WHICH
RECORD INFORMATION SHALL BE PLACED NOTING DEVIATIONS FROM THE
PLANS IN THE LOCATION, GRADE, SIZE, TYPE, AND SCOPE OF WORK WHICH IS
CONSTRUCTED.
9. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) REQUIREMENTS AND
STANDARDS SHALL BE OBSERVED AT THE JOB SITE AT ALL TIMES.
10. EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR
SHALL BE TIED OUT BY A CALIFORNIA LICENSED LAND SURVEYOR PRIOR TO
DISTURBANCE. PROPER RESETTING OF ALL EXISTING MONUMENTS AND
OTHER SURVEY MARKERS SHALL BE AT THE CONTRACTOR'S OWN EXPENSE.
ANY SURVEY MONUMENTS DISTURBED BY THE CONTRACTOR SHALL BE
REPLACED PRIOR TO OCCUPANCY BY A PROFESSIONAL LICENSED LAND
SURVEYOR IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA
BUSINESS AND PROFESSIONS ACT.
11. ALL CONSTRUCTION SHALL BE IN COMPLETE COMPLIANCE WITH ALL
RECOMMENDATIONS AND REQUIREMENTS AS SET FORTH IN THE
GEOTECHNICAL ENGINEERING REPORT, TITLED LAGUNA LAKE DOG PARK
IMPROVEMENTS 504 MADONNA ROAD SAN LUIS OBISPO, CA DATED AUGUST 4,
2023.
12. NO CONSTRUCTION SHALL BE STARTED WITHOUT PLANS APPROVED BY
THE CITY. THE CITY SHALL BE NOTIFIED AT LEAST 48 HOURS PRIOR TO
STARTING OF CONSTRUCTION. ANY CONSTRUCTION DONE WITHOUT
APPROVED PLANS OR PRIOR NOTIFICATION TO THE CITY WILL BE REJECTED
AND WILL BE AT THE CONTRACTOR'S RISK.
13. SOILS TESTS SHALL BE DONE IN ACCORDANCE WITH THE CITY OF SAN
LUIS OBISPO STANDARDS AND SPECIFICATIONS. ALL TESTS MUST BE MADE
WITHIN 15 DAYS PRIOR TO THE PLACING OF MATERIAL. THE TEST RESULTS
SHALL CLEARLY INDICATE THE LOCATION AND SOURCE OF THE MATERIAL.
14. COMPACTION TESTS SHALL BE MADE ON SUBGRADE MATERIAL AND
MATERIAL AS SPECIFIED BY THE SOILS ENGINEER AND CITY STANDARDS. SAID
TESTS SHALL BE MADE PRIOR TO THE PLACING OF THE NEXT MATERIAL.
COMPACTION REPORTS TO BE PROVIDED TO THE ENGINEER OF RECORD.
15. SITE SOILS WITHIN FLATWORK AREAS SHALL BE EXCAVATED AS
RECOMMENDED IN THE GEOTECHNICAL REPORT "LAGUNA LAKE DOG PARK
IMPROVEMENTS, 504 MADONNA ROAD, SAN LUIS OBISPO, CALIFORNIA". THE
EXPOSED SURFACES SHALL THEN BE SCARIFIED, MOISTURE CONDITIONED,
AND RECOMPACTED.
16. ALL UTILITY COMPANIES SHALL BE NOTIFIED PRIOR TO THE START OF
CONSTRUCTION.
17. CONSTRUCTION ACTIVITY ON-SITE SHALL BE LIMITED TO THE HOURS OF
7:00AM TO 4:00PM MONDAY THROUGH FRIDAY, AND EXCLUDING HOLIDAYS.
18. DESIGNS OF ALL FOUNDATIONS, ROADWAYS, CURBS, AND OTHER
STRUCTURES SHALL BE REVIEWED BY A GEOTECHNICAL ENGINEER TO
ENSURE THAT THEY ARE COMPATIBLE WITH THE SOILS PROPERTIES AND
CONDITIONS ON THE PROJECT SITE.
19. ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE
JURISDICTION OF THE CITY UTILITIES AND PUBLIC WORKS DEPARTMENTS
SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING
STANDARD AND STANDARD SPECIFICATIONS (ADOPTED AUGUST 2020).
20. PARKING LOT STRIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE
PARKING AND DRIVEWAY STANDARDS AND CITY ENGINEERING STANDARD
#2250.
21. ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT LESS
THAN 2% FINAL GRADIENTS CERTIFIED BY A LICENSED SURVEYOR OR
ENGINEER PRIOR TO FINAL INSPECTION APPROVALS.
CONSTRUCTION NOTES
1. CONTRACTOR SHALL INVESTIGATE THE SITE DURING CLEARING,
DEMOLITION AND EARTHWORK OPERATION FOR ANY EXISTING HAZARD SUCH
AS CESSPOOLS, CISTERNS, FOUNDATIONS OR LARGE DEPOSITS OF ORGANIC
MATERIAL, ETC. IF ANY SUCH HAZARDS ARE FOUND, THE OWNER AND
ENGINEER SHALL BE NOTIFIED. ALL EXISTING SURFACE STRUCTURES, FENCES,
TANKS, PIPES, ETC., AND ANY BURIED MATERIAL SPECIFIED IN THE PLANS FOR
REMOVAL FROM THE SITE SHALL BE DISPOSED OF AT A LICENSED DISPOSAL
FACILITY.
2. CONTRACTOR SHALL PROVIDE A MIN. OF 48 HOURS WRITTEN NOTICE TO
THE PROJECT REPRESENTATIVE AND SURVEYOR WHEN REQUESTING SURVEY
STAKES.
3. ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK,
OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE
SATISFACTION OF THE ENGINEER. NEW CURB, GUTTER, SIDEWALK, UTILITY
ABANDONMENTS, AND NEW UTILITIES SHALL COMPLY WITH THE LATEST CITY
ENGINEERING STANDARDS..
4. A COMPACTION REPORT SHALL BE PROVIDED FROM A LICENSED SOILS
ENGINEER STATING THAT THE BASE AND SUBGRADE WERE PREPARED IN
ACCORDANCE WITH THE PROJECT SOILS REPORT OR THE CITY PARKING AND
DRIVEWAY STANDARDS. PER THE GEOTECHNICAL ENGINEER'S
RECOMMENDATION, NON-VEHICULAR AREAS SHALL BE 90% COMPACTION AND
VEHICULAR AREAS SHALL BE 95% COMPACTION.
5. A LICENSED LAND SURVEYOR SHALL CERTIFY SEWER LATERALS WITH A
SLOPE NOT LESS THAN 18" PER FOOT OR 1% AT TIME OF INSTALLATION.
SURVEYORS FIELD REPORT SHALL INCLUDE SPOT ELEVATIONS VERIFIED AT
NOT LESS THAN 10' INTERVALS AND PROVIDED TO THE BUILDING INSPECTOR
AT OR BEFORE THE SEWER LATERAL INSPECTION.
6. THE ELEVATION OF THE FOUNDATION FORMS SHALL BE CERTIFIED BY A
LICENSED SURVEYOR OR ENGINEER FOR COMPLIANCE WITH THE APPROVED
BUILDING PLANS AND CITY ORDINANCES PRIOR TO FOUNDATION INSPECTION
APPROVALS
CUT:2,500 CU, YDS.
FILL:550 CU, YDS.
NET:1,950 CU, YDS.
QUANTITY ESTIMATES SHOWN ON THIS PLAN ARE TO BE USED FOR BONDING
AND PERMIT PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO VERIFY ACTUAL QUANTITIES FOR THE PURPOSES OF
CONSTRUCTION & BIDDING. THESE QUANTITIES DO NOT ASSUME ANY LOSSES
DUE TO SHRINKAGE, DIRT REMOVAL DUE TO UNSUITABLE SUBGRADE
MATERIAL OR REUSE OF EXISTING ASPHALT ON-SITE.
GRADING NOTES
1. IF EXCAVATIONS ENCOUNTER SIGNIFICANT PALEONTOLOGICAL
RESOURCES, ARCHAEOLOGICAL RESOURCES, OR CULTURAL MATERIAL, THEN
CONSTRUCTION ACTIVITIES THAT MAY AFFECT THEM SHALL CEASE UNTIL THE
EXTENT OF THE RESOURCE IS DETERMINED AND THE COMMUNITY
DEVELOPMENT DIRECTOR APPROVES APPROPRIATE PROTECTIVE MEASURES.
THE COMMUNITY DEVELOPMENT DIRECTOR SHALL BE NOTIFIED OF THE
EXTENT AND LOCATION OF DISCOVERED MATERIALS SO THAT A QUALIFIED
ARCHAEOLOGIST MAY RECORD THEM.
2. IF PRE-HISTORIC NATIVE AMERICAN ARTIFACTS ARE ENCOUNTERED, A
NATIVE AMERICAN MONITOR SHOULD BE CALLED INTO WORK WITH THE
ARCHAEOLOGIST TO DOCUMENT AND REMOVE THE ITEMS. DISPOSITION OF
ARTIFACTS SHALL COMPLY WITH STATE AND FEDERAL LAWS.
APPLICABLE CODES:
CALTRANS STANDARD PLANS - 2022
CBC - 2022 California Building Code
CPC - 2022 California Plumbing Code
GBC - 2022 Green Building Code
CFC - 2022 California Fire Code
SWPPP AND EROSION CONTROL
1. CONTRACTOR SHALL PREPARE SWPPP AND OBTAIN WDID NUMBER FOR
PROJECT. SWPPP SHALL BE A PART OF THE DEFERRED SUBMITTAL PACKAGE.
2. EROSION CONTROL MEASURES FOR WIND, WATER, MATERIAL
STOCKPILES, AND TRACKING SHALL BE IMPLEMENTED ON ALL PROJECTS AT
ALL TIMES AND SHALL INCLUDE SOURCE CONTROL, INCLUDING PROTECTION
OF STOCKPILES, PROTECTION OF SLOPES, PROTECTION OF ALL DISTURBED
AREAS, PROTECTION OF ACCESSES, AND PERIMETER CONTAINMENT
MEASURES. EROSION CONTROL SHALL BE PLACED PRIOR TO THE
COMMENCEMENT OF GRADING AND SITE DISTURBANCE ACTIVITIES UNLESS
THE PUBLIC WORKS DEPARTMENT DETERMINES TEMPORARY MEASURES TO
BE UNNECESSARY BASED UPON LOCATION, SITE CHARACTERISTICS OR TIME
OF YEAR. THE INTENT OF EROSION CONTROL MEASURES SHALL BE TO KEEP
ALL GENERATED SEDIMENTS FROM ENTERING A SWALE, DRAINAGE WAY,
WATERCOURSE, ATMOSPHERE, OR MIGRATE ONTO ADJACENT PROPERTIES
OR ONTO THE PUBLIC RIGHT-OF-WAY.
3. SITE INSPECTIONS AND APPROPRIATE MAINTENANCE OF ALL EROSION
CONTROL MEASURES/DEVICES SHALL BE CONDUCTED AND DOCUMENTED AT
ALL TIMES DURING CONSTRUCTION AND ESPECIALLY PRIOR TO, DURING, AND
AFTER RAIN EVENTS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PLACEMENT AND
MAINTENANCE OF ALL EROSION CONTROL MEASURES/DEVICES AS SPECIFIED
BY THE APPROVED PLAN UNTIL SUCH TIME THAT THE PROJECT IS ACCEPTED
AS COMPLETE BY THE PUBLIC WORKS DEPARTMENT OR UNTIL RELEASED
FROM THE CONDITIONS OF APPROVAL OF THEIR GENERAL PERMIT. EROSION
CONTROL MEASURES/DEVICES MAY BE RELOCATED, DELETED OR ADDITIONAL
MEASURES/DEVICES MAY BE REQUIRED DEPENDING ON THE ACTUAL
CONDITIONS ENCOUNTERED DURING CONSTRUCTION. ADDITIONAL EROSION
CONTROL MEASURES/DEVICES SHALL BE PLACED AT THE DISCRETION OF THE
ENGINEER OF WORK, CITY INSPECTOR, SWPPP MONITOR, OR RWQCB
INSPECTOR. GUIDELINES FOR DETERMINING APPROPRIATE EROSION CONTROL
DEVICES SHALL BE INCLUDED IN THE PLANS WITH ADDITIONAL
MEASURES/DEVICES NOTED FROM THE APPENDIX OF THE PUBLIC
IMPROVEMENT STANDARDS.
5. EROSION CONTROL DEVICES SHALL BE THE FIRST ORDER OF WORK AND
SHALL BE IN PLACE AT ALL TIMES DURING CONSTRUCTION. ADDITIONAL
MEASURES /DEVICES SHALL BE AVAILABLE DURING THE RAINY SEASON
(BETWEEN OCTOBER 15 AND APRIL 15) OR ANYTIME WHEN THE RAIN
PROABALITY EXCEEDS 30%. THESE MEASURES/DEVICES SHALL BE AVAILABLE,
INSTALLED, AND/OR APPLIED AFTER EACH AREA IS GRADED AND NO LATER
THAN FIVE (5) WORKING DAYS AFTER COMPLETION OF EACH AREA.
6. THE CONTRACTOR AND QSP SHALL BE RESPONSIBLE TO REVIEW THE
PROJECT SITE PRIOR TO OCTOBER 15 (RAINY SEASON) AND TO COORDINATE
AN IMPLEMENTATION PLAN FOR WET WEATHER EROSION CONTROL DEVICES.
A LOCALLY BASED STANDBY CREW FOR EMERGENCY WORK SHALL BE
AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 15 THROUGH
APRIL 15). NECESSARY MATERIALS SHALL BE AVAILABLE AND STOCK PILED AT
CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OR
MAINTENANCE OF TEMPORARY DEVICES WHEN RAIN IS IMMINENT.
7. PERMANENT EROSION CONTROL SHALL BE PLACED AND ESTABLISHED
WITH 70% COVERAGE ON ALL DISTURBED SURFACES OTHER THAN PAVED OR
GRAVEL SURFACES, PRIOR TO FINAL INSPECTION. PERMANENT EROSION
CONTROL SHALL BE FULLY ESTABLISHED PRIOR TO FINAL ACCEPTANCE.
TEMPORARY EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL
PERMANENT MEASURES ARE ESTABLISHED.
8. EFFECTIVE SOIL COVER SHALL BE IMPLEMENTED FOR AREAS SCHEDULED
TO BE INACTIVE FOR AT LEAST 14 DAYS AND ALL FINISHED SLOPES, OPEN
SPACE, UTILITY BACKFILL, AND COMPLETED LOTS.
9. THE USE OF PLASTIC MATERIALS SHALL BE LIMITED WHEN ALTERNATIVES
EXIST.
10. EFFECTIVE WIND EROSION CONTROL SHALL BE IMPLEMENTED.
11. AFTER EACH RAIN STORM, REMOVE ALL SILT AND DEBRIS FROM EROSION
& SEDIMENT CONTROL MEASURES, INCLUDING BASINS, SEDIMENT BASINS,
SEDIMENT TRAPS, AND DIVERSION EARTH SWALES.
12. ALL EQUIPMENT/ VEHICLES SHALL BE FUELED, MAINTAINED AND STORED
IN THE DESIGNATED STAGING AREA FITTED WITH APPROPRIATE BMPS.
13. STORAGE AREAS FOR MATERIALS, WASTE, WATER STORAGE, WATER
TRANSFER FOR DUST CONTROL AND COMPACTION PRACTICES SHALL BE
LOCATED WITHIN THE DESIGNATED STAGING AREAS.
14. STOCKPILED CONSTRUCTION MATERIALS NOT BEING ACTIVELY USED
SHALL BE COVERED AND BERMED PRIOR TO QUALIFYING RAIN EVENT.
15. TRACKING ONTO THE PUBLIC STREET SHALL BE MINIMIZED. THE
ADJOINING STREETS SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT,
DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY.
16. TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN
PERMANENT IMPROVEMENTS, PLANTINGS, AND FACILITIES ARE IN PLACE.
TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION.
17. MINIMIZE THE AMOUNT OF DISTURBED/EXPOSED AREA WHERE POSSIBLE.
DISTURB ONLY AREAS NECESSARY TO COMPLETE THE WORK SHOWN IN
THESE PLANS.
18. ALL PREVENTION AND CLEAN UP MEASURES SHOULD BE CONDUCTED IN
ACCORDANCE WITH CITY OF SAN LUIS OBISPO ORDINANCES, AS WELL AS
STATE AND FEDERAL REGULATIONS. WASTE MATERIALS SHALL BE DISPOSED
OF IN A LEGAL MANNER.
19. ALL DISCHARGES OF STORM WATER MUST COMPLY WITH THE LAWFUL
REQUIREMENTS OF THE CITY OF SAN LUIS OBISPO AND OTHER LOCAL
AGENCIES REGARDING THE DISCHARGES OF STORM WATER TO STORM DRAIN
SYSTEMS.
20. THIS PLAN DOES NOT COVER THE REMOVAL OF HAZARDOUS OR TOXIC
WASTE. IN THE EVENT OF A DISCHARGE OR RELEASE OF A REPORTABLE
QUANTITY OF TOXIC WASTE, CONSTRUCTION ACTIVITIES SHOULD BE STOPPED
UNTIL THE SPILL CAN BE ASSESSED AND A MITIGATION REPORT PREPARED BY
A QUALIFIED ENVIRONMENTAL CONSULTANT, AND IF NECESSARY, REVIEWED
BY THE CITY OF SAN LUIS OBISPO AND ANY OTHER AGENCY HAVING
JURISDICTION.
AIR QUALITY MITIGATION NOTES
THE FOLLOWING DUST MITIGATION MEASURES ARE REQUIRED AT THE START
AND MAINTAINED THROUGHOUT THE DURATION OF THE CONSTRUCTION OR
GRADING ACTIVITY:
1. CONSTRUCTION VEHICLE SPEED AT THE WORK SITE MUST BE LIMITED TO
FIFTEEN (15) MILES PER HOUR OR LESS;
2. PRIOR TO ANY GROUND DISTURBANCE, SUFFICIENT WATER MUST BE
APPLIED TO THE AREA TO BE DISTURBED TO PREVENT VISIBLE EMISSIONS
FROM CROSSING THE PROPERTY LINE;
3. AREAS TO BE GRADED OR EXCAVATED MUST BE KEPT ADEQUATELY
WETTED TO PREVENT VISIBLE EMISSIONS FROM CROSSING THE PROPERTY
LINE;
4. STORAGE PILES MUST BE KEPT ADEQUATELY WETTED, TREATED WITH A
CHEMICAL DUST SUPPRESSANT, OR COVERED WHEN MATERIAL IS NOT BEING
ADDED TO OR REMOVED FROM THE PILE;
5. EQUIPMENT MUST BE WASHED DOWN BEFORE MOVING FROM THE
PROPERTY ONTO A PAVED PUBLIC ROAD;
6. VISIBLE TRACK-OUT ON THE PAVED PUBLIC ROAD MUST BE CLEANED
USING WET SWEEPING OR HEPA FILTER EQUIPPED VACUUM DEVICE AT THE
END IF EACH DAY,
7. NO PERSON SHALL ENGAGE IN ANY CONSTRUCTION OR GRADING
OPERATION ON PROPERTY WHERE THE AREA TO BE DISTURBED IS GREATER
THAN ONE (1.0) ACRE UNLESS A GEOLOGIC EVALUATION HAS OCCURRED ON
SITE. IF ASBESTOS CONTAINING ROCK IS DETERMINED TO BE ON SITE AN
ASBESTOS DUST MITIGATION PLAN WILL BE REQUIRED TO BE SUBMITTED TO
AND APPROVED BY THE DISTRICT BEFORE THE START OF ANY CONSTRUCTION
OR GRADING ACTIVITY; AND THE PROVISIONS OF THAT DUST MITIGATION PLAN
MUST BE IMPLEMENTED AT THE BEGINNING AND MAINTAINED THROUGHOUT
THE DURATION OF THE CONSTRUCTION OR GRADING ACTIVITY; AND
8. A PRE-CONSTRUCTION MEETING SHALL BE REQUIRED TO INFORM
CONSTRUCTION CREW OF SITE REQUIREMENTS.
9. ALL MATERIAL EXCAVATED OR GRADED SHALL BE SUFFICIENTLY
WATERED TO PREVENT EXCESSIVE AMOUNTS OF DUST. DURING THE TIME
PERIOD IN WHICH GRADING WILL OCCUR, WATERING SHALL OCCUR USING
NONPOTABLE WATER, OR OTHERWISE AS NEEDED TO THE APPROVAL OF THE
CITY INSPECTOR, AT LEAST TWICE DAILY INCLUDING WEEKENDS WITH
COMPLETE COVERAGE, PREFERABLY IN THE LATE MORNING AND AFTER WORK
IS FINISHED FOR THE DAY.
10. ALL CLEARING, GRADING EARTH-MOVING, OR EXCAVATING ACTIVITIES
SHALL CEASE DURING PERIODS OF HIGH WINDS (GREATER THAN 15MPH
AVERAGED OVER ONE HOUR) TO PREVENT EXCESSIVE AMOUNTS OF DUST.
11. IF SOIL MATERIALS ARE TRANSPORTED OFF-SITE, TRUCKS SHALL BE
COVERED OR HAVE ALT LEAST TWO FEET OF FREEBOARD TO MINIMIZE DUST
AND PREVENT LOOSE SOIL FROM SPILLING OUT.
12. ALL DISTURBED AREAS NOT SUBJECT TO REVEGETATION SHALL BE
STABILIZED USING APPROVED LANDSCAPED PLANTING, CHEMICAL SOIL
BINDERS, JUTE NETTING OR OTHER METHODS APPROVED IN ADVANCE BY THE
ENGINEER OF RECORD.
TREE PROTECTION NOTES
1. PROTECTION FENCES
INSTALL A 5-FOOT TALL FENCE AROUND DRIP-LINE OF TREES TO BE SAVED, OR
AS DIRECTED BY THE ENGINEER, BEFORE ANY WORK STARTS ON THE SITE.
THE TREE PROTECTION FENCE MUST BE ORANGE SAFETY FENCING SECURED
WITH STEEL T-POSTS SET AT 8 FEET ON CENTER.
TREE PROTECTION FENCES MUST:
1. BE INSTALLED BEFORE ANY WORK BEGINS
2. REMAIN IN PLACE
3. CONTINUALLY MAINTAINED
4. REMOVED AS THE LAST ITEM OF CONTRACT WORK
2. PRUNING
PRUNING OF TREE LIMBS WILL ONLY BE ALLOWED IF APPROVED BY THE
ENGINEER. TREE PRUNIN MUST BE DONE BY A CERTIFIED ARBORIST PER
INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA) STANDARDS.
3. PARKING AND STORAGE OF BUILDING MATERIALS
DO NOT:
1. PARK VEHICLES
2. PARK CONSTRUCTION EQUIPMENT
3. STOCKPILE
WITHIN THE DRIP-LINE OF TREES TO BE SAVED.
4. DUMPING
DO NOT DEPOSIT:
1. WATER
2. WASTE
3. CONSTRUCTION MATERIALS
WITHIN 20 FEET OF DRIP-LINE OF TREES TO BE SAVED.
5. HERBICIDE USE
DO NOT USE HERBICIDE INCLUDING PRE AND POST EMERGENT WITHIN 20 FEET
OF DRIP-LINE OF TREES TO BE SAVED
6. TRUNK PROTECTION
DO NOT ATTACH ANYTHING TO ANY PORTION OF TREES TO BE SAVED. IF YOU
WOUND A TREE TO BE SAVED, IMMEDIATELY EXPAND TREE PROTECTIVE
FENCING AND TREAT TREE WOUND TO THE SATISFACTION OF THE ENGINEER.
IF SEVERE TREE DAMAGE OCCURS YOU MAY BE FINED IN COMPLIANCE WITH
THE CITY'S TREE ORDINANCE.
7. EXCAVATION, GRADING, TRENCHING AND BORING
NO TRENCHING OF ANY DEPTH WILL BE ALLOWED WITHIN THE DRIP-LINE OF
TREES OR SHRUBS TO BE SAVED, UNLESS APPROVED BY THE ENGINEER. IF
YOU PLAN TO TRENCH WITHIN 20 FEET OF THE DRIP0LINE OF TREE TO BE
SAVED, LAYOUT TRENCH LOCATION WITH CHALK OR PAINT, AND NOTIFY THE
ENGINEER FOR REVIEW AND APPROVAL BEFORE TRENCHING WORK BEGINS. IF
THE ENGINEER APPROVES TRENCHING WITHIN THE DRIP-LINE OF TREES OR
SHRUBS TO BE SAVED, TRENCHING EXCAVATION MUST BE DONE BY HAND.
TRENCHING OUTSIDE THE DRIP-LINE OF TREES TO BE SAVED AND WITHIN 20
FEET OF DRIP-LINE OF TREES TO BE SAVED IS NOT REQUIRED TO BE
COMPLETED BY HAND.
NO GRADING CUTS OR FILLS WILL BE ALLOWED WITHIN THE DRIP-LINE OF
TREES TO BE SAVED, UNLESS APPROVED BY THE ENGINEER.
DURING EXCAVATION IF ANY ROOTS ARE ENCOUNTERED LESS THAN 1-INCH IN
DIAMETER, THE ROOT MAY BE CUT BY HAND LEAVING A CLEAN CUT.
DURING EXCAVATION IF ANY ROOTS ARE ENCOUNTERED GREATER THAN
1-INCH IN DIAMTER, THE ROOT MUST BE PROTECTED FROM:
1. SCARRING
2. DRYING
3. THEN TUNNELED UNDER
IF THE ROOT CANNOT BE PROTECTED, YOU MUST SCHEDULE THE ENGINEER
AND CITY ARBORIST TO REVIEW EXCAVATION AND GIVE DIRECTION.
SHADE ROOTS FROM DIRECT SUNLIGHT WHEN EXPOSED IN OPEN TRENCH.
THE ENGINEER MUST REVIEW PRUNED OR CUT ROOTS PRIOR TO BACKFILLING
TRENCH. TRENCH MUST BE BACKFILLED WITHIN 24 HOURS OF ENCOUNTERING
ROOTS.
ALL DIRECTIONAL BORING WITHIN DRIP-LINE TREES TO BE SAVED MUST
MAINTAIN A MINIMUM DEPTH OF 5 FEET.
IF SEVERE TREE OR ROOT DAMAGE OCCURS YOU MAY BE FINED IN
COMPLIANCE WITH THE CITY'S TREE ORDINANCE.
8. TREE REMOVALS
TREES NOT SHOWN AND IDENTIFIED ON THE PLANS TO BE REMOVED, BUT ARE
REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE WORK, ARE
SUBJECT TO THE CITY'S TREE REMOVAL POLICIES AND PROCEDURES.
COORDINATE TREE REMOVAL POLICY COMPLIANCE WITH ENGINEER.
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
BDH
CPK
BDH
12/21/2023
LEGEND
//////EXISTING EDGE OF PAVEMENT
ABANDON UTILITY
UNDERGROUND CABLE
TELEVISION LINECTVCTV
UNDERGROUND ELECTRICAL
LINEELEELE
UNDERGROUND GAS LINEGASGAS
UNDERGROUND
TELECOMMUNITCATIONS LINETCOMTCOM
UNDERGROUND UTILITY LINEUTLUTL
GRAVITY SEWER LINESSSS
STORM DRAINSDSD
WATER LINEWLWL
RIGHT OF WAY
EASEMENT
CENTERLINE
BARBED WIRE FENCEX (BW)
CHAIN LINK FENCEX (CL)
WOOD FENCE••••
EXISTING PROPOSED DESCRIPTION
SD SD
SS
CO
SS
SDSD
SS SS
SLOPE
SPOT ELEVATIONS
SEWER CLEANOUT
SEWER MANHOLE
CO
SEWER LATERAL
0.50%2:1
FG= 225.45EG= 225.45
0.50%2:1
FIRE HYDRANT
WATER SERVICE
WATER SERVICE MANIFOLD
STORM DRAIN MANHOLE
STORM DRAIN CURB INLET
STORM DRAIN CATCH BASIN
SD STORM DRAINSD
SSFM SEWER FORCE MAINSSFM
IRR EXISTING IRRIGATION LINE
••••
Page 28 of 57
100
101
102
103
104
SURVEY CONTROL POINTS
PT. NO.
100
101
102
103
104
NORTHING
2293553.06
2293502.83
2293588.59
2293206.52
2293001.46
EASTING
5760917.49
5760875.26
5760762.90
5761126.06
5760930.42
ELEV.
146.88
144.56
143.40
148.30
139.47
DESC.
SET 5/8 REBAR 'WG CONTROL'
SET 5/8 REBAR 'WG CONTROL'
SET MAG NAIL IN PAINT STRIPE
SET MAG NAIL 'WG CONTROL'
SET MAG NAIL 'WG CONTORL'
SHEET LAYOUT AND SURVEY CONTROL
VICINITY MAP
SURVEY NOTES
1. THE HORIZONTAL DATUM FOR THIS SURVEY IS THE NORTH AMERICAN
DATUM OF 1983, 1992 ADJUSTMENT [NAD83(1992)], EPOCH DATE OF
1991.35 ACCORDING TO THE CITY OF SAN LUIS OBISPO HORIZONTAL
CONTROL NETWORK, JANUARY 2007 REVISION.
2. THE PROJECTION USED IS THE CALIFORNIA COORDINATE SYSTEM OF
1983 (CCS83), ZONE 5 PROJECTION ACCORDING TO THE CITY OF SAN
LUIS OBISPO'S HORIZONTAL CONTROL NETWORK, JANUARY 2007
REVISION.
3. THIS SURVEY TIED TO TWO CITY OF SAN LUIS OBISPO HORIZONTAL
CONTROL POINT STATIONS. THOSE STATIONS ARE DESIGNATED "8118",
HAVING A PUBLISHED POSITION OF: NORTHING 2291824.331', EASTING
5759987.692'; AND "8120", HAVING A PUBLISHED POSITION OF: NORTHING
2292760.657', EASTING 5759556.922'. THE RECORD BEARING FROM
••••••••• ••••••••••••• •••• ••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••HE BEARINGS
SHOWN HEREON ARE REFERENCED TO CCS83, ZONE 5 GRID NORTH
ACCORDING TO THE CITY OF SAN LUIS OBISPO'S HORIZONTAL
CONTROL NETWORK, JANUARY 2007 REVISION.
4. ALL MEASUREMENTS LISTED, SHOWN AND REPRESENTED HEREON ARE
BASED ON GRID DISTANCES OF THE CALIFORNIA COORDINATE SYSTEM
OF 1983 ZONE 5 PROJECTION ACCORDING TO THE CITY OF SAN LUIS
OBISPO'S HORIZONTAL CONTROL NETWORK, JANUARY 2007 REVISION.
THE COMBINED SCALE FACTOR FOR THE PROJECT IS 0.999961444 THIS
SCALE FACTOR WAS CALCULATED USING AN ELEVATION OF 130.53
FEET FOR PT. NO. 106 (CITY VERTICAL BM# 327). DIVIDE THE DISTANCES
HEREON BY THE COMBINED SCALE FACTOR TO OBTAIN GROUND
DISTANCES. ALL DISTANCES SHOWN ARE U.S. SURVEY FEET.
5. THE CONVERGENCE ANGLE IS: •• ••• • ••• • •• • •••••••••••••••••AT PT. NO. 327.
6. THE ORTHOMETRIC HEIGHTS (ELEVATIONS) ARE BASED ON THE NORTH
AMERICAN VERTICAL DATUM OF 1988 (NAVD88) ACCORDING TO THE
CITY OF SAN LUIS OBISPO BENCH MARK SYSTEM, JANUARY 2007
REVISION. THIS SURVEY TIED TO THE POINT DESIGNATED AS PT. NO
327 OF THE CITY OF SAN LUIS OBISPO BENCH MARK SYSTEM, JANUARY
2007 REVISION, HAVING A PUBLISHED ELEVATION OF 130.53'.
7. THE CONTOUR INTERVAL IS 1 FOOT.
8. ORTHOPHOTOGRAPHY PRODUCED BY WALLACE GROUP.
PHOTOGRAPHY DATED: 10/28/2022
9. UNDERGROUND UTILITY LOCATIONS ARE PLOTTED BASED ON ABOVE
GROUND PAINT MARKS BY OTHERS, ABOVE GROUND SURFACE
STRUCTURES. ACTUAL LOCATION MAY DIFFER. ADDITIONAL
UNDERGROUND UTILITY LINES MAY EXIST. FOR INFORMATION
REGARDING UTILITY LOCATION, SIZE, DEPTH, CONDITION, AND
CAPACITY CONTACT UTILITY OR MUNICIPAL/PUBLIC SERVICE FACILITY.
10. UNDERGROUND PIPE SIZES ARE BASED ON VISUAL OBSERVATIONS
MADE FROM THE SURFACE AND ARE APPROXIMATE.
11. THIS IS NOT A BOUNDARY SURVEY. NO BOUNDARY LINES ARE
DEPICTED AND NO BOUNDARY EVIDENCE WAS REVIEWED. NO TITLE
INFORMATION WAS PROVIDED FOR THIS PROJECT.
SHEET SC-2
SHEET SC-3
DA
L
I
D
I
O
D
R
.
No. 9688
N.T.S.
MADO
N
N
A
R
D
L
O
S
O
S
O
S
V
A
L
L
E
Y
R
D
LAGUNA
LAKE
D
A
L
I
D
I
O
R
D
LAGUNA LAKE
DOG PARK
FILE NAME: 061-118 SRVY.DWG
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
12/21/2023
Page 29 of 57
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////
//
/
/
/
/
//
/
//
/
/
/
/
/
/
/
GATE
TRASH CAN
TRASH CAN
36" MULTI -
TRUNK CYP
9" REDWOOD
4" CYP
4" CYP
4" CYP
4" CYP
9" CYP
8" STUMP
12" STUMP
12" STUMP
12" STUMP
18" STUMP
PLANT
PROTECTION
SILT FENCE
PLANT
PROTECTION
SILT FENCE
WOOD BRIDGE
BIKE RACK
TRASH CAN
/
/
/
/
/
/
//
/
//
/
/
/
/
/
/
/
/
/
/
///
/
/
/
/
/
/
///
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//////
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
WATER SPIGOT
& DRAIN
INV 8" PVC
=139.21'
RESTROOMS
TRANSMISSION
LINE TOWER
METAL GATE
DAMAGED
PAVEMENT
DAMAGED
PAVEMENT
13
5
14
0
14
5
135
140
14
5
14
5
TRAIL
TRAIL
TRAIL
ABANDONED
WATER SPIGOT
& DRAIN
BLOCK WALL
BL
O
C
K
W
A
L
L
DI RIM=143.36'
INV(NW)12" HDPE=141.41'
SD
BOULDER
(TYP.)
BOULDER
(TYP.)
ABANDONED
WATER SPIGOT
& DRAIN
POST
DI
R
T
R
O
A
D
DI
R
T
R
O
A
D
DI RIM=142.38'
INV(NW)8" PVC=140.46'
INV(SE)12" HDPE=140.88'
INV(E)6" PVC=141.00'
WHEEL STOP
(TYP.)
CONCRETE PAD &
BENCH (TYP.)
DA
L
I
D
I
O
D
R
.
18" TREE
PO
L
E
F
E
N
C
E
(
T
Y
P
.
)
PO
L
E
F
E
N
C
E
(
T
Y
P
.
)
2" RISER
100
101
102
LEGEND
//////EDGE OF PAVEMENT
CHAIN LINK FENCE
POLE FENCE
SD STORM DRAIN LINE
SS SANITARY SEWER LINE
O/H OVERHEAD UTILITY LINE
AREA LIGHT
LIGHT STANDARD
SANITARY SEWER MANHOLE
FIRE HYDRANT
WATER METER
IRRIGATION CONTROL VALVE
WATER VALVE
GUY POLE
GUY WIRE
SANITARY SEWER CLEAN OUT
STREET SIGN/SIGN POST
SURVEY CONTROL POINT AND NUMBER
BRUSH LINE/DRIP LINE
INTERMEDIATE CONTOUR
INDEX CONTOUR
POLE WITH LIGHT
TRAFFIC STRIPING (SOLID)
CO
S
20" PINE TREE WITH DIAMETER NOTED
BUILDING
CONCRETE
TRAFFIC STRIPING (DASHED)
BOULDER
TREE STUMP
CONCRETECONC
DRAINAGE INLETDI
TYPICALTYP.
BRICK
BLOCK WALL
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
MATCHLINE- SEE SHEET SC-3
FILE NAME: 061-118 SRVY.DWG
No. 9688
12/21/2023
Page 30 of 57
SSMH RIM=145.78
INV (NW) 8" = 137.08'
INV (S) 8" = 137.08'
/////////
///
///
///
///
///
///
//////
//////
//////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
//////
//////
//////
///
///
///////////////
/
/
/
///
TRAIL
2-6" LIVE OAK
18" LIVE OAK
15" LIVE OAK
2-4" LIVE OAK
24" LIVE OAK
15" STUMP
27" STUMP
27" STUMP
25" STUMP
21" STUMP
12" STUMP
15" STUMP
12" STUMP
15" STUMP
6" STUMP
12" STUMP
12" STUMP
12" STUMP
8 STUMP
12" STUMP
18" STUMP
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O/
H
O14
14
14
0
145
1
4
0
1
4
5
TRAIL
TRAIL
BENCH
CONC DISC
GOLF TEE
BOULDER
(TYP.)
DA
L
I
D
I
O
D
R
.
ADA PARKING SIGN
TREE
6" TREE
PO
L
E
F
E
N
C
E
(
T
Y
P
.
)
POLE FENCE (TYP.)
TRANSMISSION
LINE TOWER
PARK
SIGN
103
104
LEGEND
//////EDGE OF PAVEMENT
CHAIN LINK FENCE
POLE FENCE
SD STORM DRAIN LINE
SS SANITARY SEWER LINE
O/H OVERHEAD UTILITY LINE
AREA LIGHT
LIGHT STANDARD
SANITARY SEWER MANHOLE
FIRE HYDRANT
WATER METER
IRRIGATION CONTROL VALVE
WATER VALVE
GUY POLE
GUY WIRE
SANITARY SEWER CLEAN OUT
STREET SIGN/SIGN POST
SURVEY CONTROL POINT AND NUMBER
BRUSH LINE/DRIP LINE
INTERMEDIATE CONTOUR
INDEX CONTOUR
POLE WITH LIGHT
TRAFFIC STRIPING (SOLID)
CO
S
20" PINE TREE WITH DIAMETER NOTED
BUILDING
CONCRETE
TRAFFIC STRIPING (DASHED)
BOULDER
TREE STUMP
CONCRETECONC
DRAINAGE INLETDI
TYPICALTYP.
BRICK
BLOCK WALL
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FILE NAME: 061-118 SRVY.DWG
MATCHLINE- SEE SHEET SC-2
FILE NAME: 061-118 SRVY.DWG
No. 9688
12/21/2023
Page 31 of 57
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//
//////////////////
/
/
/
/
//
/
/
/
/
/
/
/
/
/
///////////////
///
///
///
///
///
///
////////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
/////////////////////
///
///
///
///
///
///////////////
////
//
/////////
/
/
/
//////
/
/
/
/
//
//////////////////
//////
/
/
/
/
/
/
O/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/H
O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H
SD
BEGIN LOG BARRIER REMOVAL
N:2293464.1220
E:5760948.8670
END LOG BARRIER REMOVAL
N:2293548.3120
E:5760769.4280
IR
R
IR
R
IR
R
IR
R
IR
R
IR
R
IR
R
IRR
IR
R
IR
R
IR
R
I
R
R
IR
R
IR
R
WLWLWLWLWLWLWL
W
L
W
L
W
L
W
L
W
L
W
L
SSSSSSSSSSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
BEGIN LOG BARRIER REMOVAL
N:2293045.1400
E:5760902.0830
END LOG BARRIER REMOVAL
N:2293021.7920
E:5760874.8600
BEGIN LOG BARRIER REMOVAL
N:2293267.4301
E:5761084.4354 END LOG BARRIER REMOVAL
N:2293294.2336
E:5761066.0740
FILE NAME: 061-118 DEMO.DWG
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
EXIST ASPHALT
REFERENCE KEYNOTES
101 PROTECT IN PLACE EXIST RESTROOM
102 PROTECT IN PLACE EXIST CONCRETE
103 PROTECT IN PLACE EXIST IRRIGATION CONTROL VALVE
104 PROTECT IN PLACE EXIST LOG BARRIER
105 PROTECT IN PLACE EXIST TREE
106 PROTECT IN PLACE EXIST SANITARY SEWER CLEANOUT
201 REMOVE EXIST INFORMATION KIOSK
202 RELOCATE EXIST TRASH RECEPTACLE. SEE SHEETS
SL-1 AND SL-2 FOR NEW LOCATION
203 RELOCATE EXIST BOULDER. SEE SHEETS SL-1 AND SL-2
FOR NEW LOCATION
301 REMOVE AND DISPOSE OF EXIST SILT FENCE
302 REMOVE AND DISPOSE OF EXIST BLOCK WALL AND
FOUNDATION
303
REMOVE AND DISPOSE OF EXIST WATER SPIGOT AND
DRAIN. ABANDON EXISTING WATER LINE AND SD PIPE.
CAP AT WATER MAIN CONNECTION
304 REMOVE AND DISPOSE OF EXIST CONCRETE
305 REMOVE AND DISPOSE OF EXIST BENCH
306 REMOVE AND DISPOSE OF EXIST LOG BARRIER,
RETURN TO CITY
307 REMOVE AND DISPOSE OF EXIST TREE AND GRIND
STUMP
308 REMOVE AND DISPOSE OF EXIST CHAIN LINK FENCE
309 REMOVE AND DISPOSE OF EXIST SIGN
310 REMOVE AND DISPOSE OF EXIST WHEEL STOP
311 REMOVE AND DISPOSE OF EXIST STORM DRAIN INLET
312 REMOVE AND DISPOSE OF EXIST TRENCH DRAIN
313 REMOVE AND DISPOSE OF EXIST STORM DRAIN PIPE
314 GRIND EXIST TREE STUMP
315 REMOVE EXISTING PAINT STRIPING
401 RELOCATE EXIST DOG BAG DISPENSER AND SIGNS
101102 102
302
103
103
103
104
306
308
105
401
401
202 202 202
203(TYP.)
301
301
302
303
303
304
304
304
304
303
304
105
105
305
305
305
304
305
306
307
307
314
314
314
314
314
314
314
314
306
306
308
104
309
309
309
309 310
310 310 310
311
312
302
313
DALIDIO DRIVE
308
104
106
32'306
314
315
315
315 315 315 315 315 315 315315
201
310
310 310
309
36" MULTI-TRUNK CYPRESS IN POOR HEALTH
9" REDWOOD IN POOR HEALTH
Page 32 of 57
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
•
•
••
•
•
••
••
••
••
••
••
••
••
••
••
••
••••••••••
••
••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••
••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••••••••••••••••••••••••••
••
••••
••
••
••
••
••
••
••
••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//
/
//
/
/
/
/
////
///
///
///
///
///
/////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
/
/
/
/
//
////////////////////////
/
/
/
/
/
/
SD
8.
0
0
'
6
.
0
0
'
4.
5
0
'
6.
0
0
'
3.
0
0
'
5.
9
0
'
3.
5
0
'
L 1
L 2
L
3
C 1
L 5 L
6
L 7
C
3
C
4
C
5
C 6L
8
C 7
C 8
C 9
L 9
C 1
0
L 10
L 11
C
2
L 1
2
L 13
C 16
C
1
7
C
1
8
C
1
9
C
2
0
L 14
C 11
L 15
L 16
C 12
L 17
L
1
8
L 19
L
2
0
L 21
C 13
C
1
4
C 15
C 21
C 22
C 2
3
C
2
4
L 4
C 25
C 26
C 27
C 28
C 29
C 30
L 32
L 33L 35
L 36
L 37
C 36
C 37
C
3
8
L 40
C 39
L 41
L 42
L 43
L
4
4
L
4
5
L 46
C 40
C 41
C 42
C
4
4
L 4
7
L 48
L
4
9
L
5
0
L 51
L
5
2
L 53L 54
L
5
5
L
5
6
L 57
L
5
8
L 59
L
6
0
C 4
8
C
4
9
C
5
0
L
6
4
L 65
L
6
6
C
5
1
L 22
L 69
C
5
2
C
5
3
C
5
4
C
5
5
L 74
L 75
L 76
L 77 L 7
8
L 7
9
L 8
0
L 8
1
L 82
C 56
C 57
C 58
L
8
6
END FENCE
N:2293557.3468
E:5760729.2188BEGIN FENCE
N:2293550.5122
E:5760760.4607
BEGIN FENCE/END FENCE (LOOP)
N:2293167.8746
E:5761046.5898
N:2293163.2550
E:5761050.4187
N:2293051.8904
E:5760917.5064
N:2293037.2661
E:5760899.8508
N:2293018.7903
E:5760877.7734
L 23
L 88
Curve Table
Curve #
C 1
C 2
C 3
C 4
C 5
C 6
C 7
C 8
C 9
C 10
C 11
C 12
C 13
C 14
Length
38.93
23.68
18.28
15.27
10.87
19.50
12.80
6.26
13.65
14.20
33.71
5.29
208.86
27.31
Radius
174.50
32.25
46.25
36.25
32.25
32.25
36.25
38.25
36.25
32.25
31.00
35.00
245.00
34.50
Delta
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• •• • •• • •••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• •• • •• • •••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
Curve Table
Curve #
C 15
C 16
C 17
C 18
C 19
C 20
C 21
C 22
C 23
C 24
C 25
C 26
C 27
C 28
Length
66.75
35.33
35.33
24.37
27.18
33.71
66.75
169.49
90.06
90.06
76.90
98.70
119.51
54.34
Radius
30.00
19.00
19.00
13.00
25.00
31.00
30.00
204.50
48.00
48.00
75.50
71.50
155.50
68.50
Delta
••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
••••••••••••••••••••
• • •• • •• • ••••••••••
••••••••••••••••••••
••••••••••••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
Curve Table
Curve #
C 29
C 30
C 36
C 37
C 38
C 39
C 40
C 41
C 42
C 44
C 48
C 49
C 50
C 51
Length
106.64
101.70
22.48
31.05
7.68
5.90
112.66
105.32
56.50
13.87
17.27
6.03
17.44
34.28
Radius
200.00
194.00
24.50
30.50
24.50
20.50
100.00
38.00
36.00
36.25
17.50
17.50
17.50
11.50
Delta
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
••••••••••••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
••••••••••••••••••••
Curve Table
Curve #
C 52
C 53
C 54
C 55
C 56
C 57
C 58
Length
23.39
15.99
12.94
17.26
145.60
224.57
196.94
Radius
19.00
13.00
18.00
24.00
162.00
455.00
124.75
Delta
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
• • •• • •• • ••••••••••
Line Table
Line #
L 1
L 2
L 3
L 4
L 5
L 6
L 7
L 8
L 9
L 10
L 11
L 12
L 13
Length
44.54
89.22
22.44
30.41
97.73
9.63
92.84
4.01
4.01
4.01
4.02
4.00
4.00
Direction
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
Line Table
Line #
L 14
L 15
L 16
L 17
L 18
L 19
L 20
L 21
L 22
L 32
L 33
L 35
L 36
Length
2.60
2.60
4.05
2.73
24.74
30.00
29.64
25.16
8.83
10.00
210.57
10.00
16.26
Direction
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
Line Table
Line #
L 37
L 40
L 41
L 42
L 43
L 44
L 45
L 46
L 47
L 48
L 49
L 50
L 51
Length
16.45
3.99
4.05
6.05
4.89
22.50
22.50
15.00
39.43
292.12
73.45
10.00
10.00
Direction
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
Line Table
Line #
L 52
L 53
L 54
L 55
L 56
L 57
L 58
L 59
L 60
L 64
L 65
L 66
L 69
Length
6.00
10.01
6.00
173.40
10.00
10.00
6.00
10.00
130.80
24.20
6.00
28.79
8.87
Direction
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
Line Table
Line #
L 74
L 75
L 76
L 77
L 78
L 79
L 80
L 81
L 82
L 86
L 88
Length
7.01
7.06
7.53
4.00
20.50
20.50
20.50
20.05
17.08
67.59
210.80
Direction
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
•••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
••••••••••••••••••••••
•••••••••••••••••••
•••••••••••••••••••
•••••••••••••••••••
••••••••••••••••••••••
FILE NAME: 061-118 HORZ.DWG
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
EXIST ASPHALT
EXIST
RESTROOM
BUILDING
EXIST CONCRETE
6.00'
10
.
0
0
'
6.
0
0
'
10
.
0
0
'
6.00'
6.0
0
'
5
.
0
0
'
LEGEND:
ACCESSIBLE PATH OF TRAVEL
Page 33 of 57
••
••
••
••
••
••
••
••
••
••
••
•
•
••
••
•
•
•
•
••
••
•
•
••
••
••
••
••
•
•
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••
••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••
••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••••••••••••••••••••••••••
••
••
•
•
••
••
••
••
••
••
••
••
••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
135
14
0
132
133
134
136
137
138
139
141
142
1
4
3
135
140
1
4
5
14
5
136
137
138
139
141
142
143
144
140
145
139
141
142
143
144
146
140
145
139
141
142
143
144
146
1
4
7
140
145
139
141
142
143
144
146
147
1
4
8
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//
/
/
/
/
/
/
/
/
/
//////////////////
///
///
///
///
///
////////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
/////////////////////
///
///
///
///
///
///
///////////////////
//
/////////
/
/
/
//////
/
/
/
/
/
/
//////////////////
//////
/
/
/
/
/
/
O/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/H
O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H
SD
1
4
0
1
3
9
1
4
1
1
4
2
FILE NAME: 061-118 GRAD.DWG
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
SHEET C-3.1SHEET C-3.2
SHEET C-3.3 SHEET C-3.4
Page 34 of 57
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••
••
••••••••
••
••
••
••
••
••
••
••
••
••
••
•
•
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••
14
0
139
141
142
1
4
3
40
1
4
5
14
5
141
142
143
144
/
//
/
//
/
/
/
/
/
/
/
/
/
/
/
/
///
///////////////
/
/
/
/////////
/
/
/
/
/
/
/
/
/
/
/
/
///
/////////////////////////////////////////////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
12" HDPE SD
3.04 LF @ 0.50% SLOPE
12" HDPE SD
3.78 LF @ 0.50% SLOPE
4" PVC SD
7.27 LF @ 2.00% SLOPE
EXIST 8" PVC SD
27.13 LF @ 4.61% SLOPE
CURB INLET #1
TC=143.89
FL(IN)=142.64
FL(OUT)=141.28
EXIST 24x24 SD INLET #2
TG=142.43
FL(IN)=140.46
FL(OUT)=140.46
SD SD SD
EG: 14
3
.
5
6
EG: 14
3
.
6
2
FS: 144
.
1
5
FS: 14
4
.
3
1
0.
2
3
%
1.35%
0.
2
7
%
0.
2
9
%
0.
7
0
%
0.84%0.84%0.84%
FS: 144.1
7
FS:
1
4
4
.
3
0
1.5
4
%
1.62
%
FS: 1
4
3
.
3
7
FS: 143.25
FS: 14
2
.
8
9
FS: 143.61
FS: 14
3
.
1
9
FS:
1
4
4
.
2
8
FS: 144.38
FS:
1
4
4
.
9
8
FS: 1
4
4
.
8
8
FS: 145.0
8
FS: 145.06
FS: 143.79
EG:
1
4
3
.
7
9
FS: 143.66
EG: 1
4
3
.
6
2
FS: 143.57
EG: 1
4
3
.
5
6
FS: 143.46
EG: 1
4
3
.
4
6
144
.
8
2
T
C
144
.
3
2
F
L
FS: 1
4
4
.
3
2
14
4
.
6
0
T
C
14
4
.
1
0
F
L
FS: 1
4
4
.
2
2
144
.
3
6
T
C
14
3
.
8
6
F
L
FS: 1
4
4
.
1
1
14
4
.
1
2
T
C
14
3
.
6
2
F
L
FS: 1
4
4
.
0
0
144.2
5
T
C
143.7
5
F
L
144.2
0
T
C
143.7
0
F
L
144.1
2
T
C
143.6
2
F
L
14
4
.
0
4
T
C
14
3
.
5
4
F
L
14
3
.
9
6
T
C
14
3
.
4
6
F
L
144.71
T
C
144.21
F
L
1
4
4
.
3
3
T
C
1
4
3
.
8
3
F
L
3.
6
1
%
3.
3
0
%
3.
6
9
%
2.
0
0
%
145.09 TC
144.59 FL
E
G
:
1
4
4
.
5
3
E
G
:
1
4
4
.
3
9
EG
:
1
4
4
.
2
8
E
G
:
1
4
4
.
6
9
144.9
2
T
C
144.4
2
F
LFS:
1
4
4
.
8
9
FS:
1
4
4
.
7
9
FS: 1
4
4
.
8
4
FS: 14
4
.
6
7
FS: 1
4
4
.
6
4
FS: 144.44
FS: 144.44
FS: 14
5
.
8
1
FS: 1
4
3
.
9
1
FS: 143
.
7
6
FS: 144.68
FS
:
1
4
4
.
7
7
1.16%
1
.
4
3
%
0.54
%
0.50%
0.11%
FS:
1
4
4
.
6
4
FS: 144.
6
7
FS: 145.88
1.0
9
%
0.
5
6
%
1.7
6
%
1.7
7
%
1.7
6
%
1
.
5
0
%
1.
4
3
%
0.1
4
%
FS:
1
4
3
.
3
2
FS
:
1
4
3
.
4
4
FS: 14
3
.
3
8
1
.
6
5
%
1.63
%
FS: 14
4
.
2
1
EG: 14
3
.
5
2
FS: 1
4
3
.
5
2
EG:
1
4
3
.
9
2
FS: 1
4
4
.
6
7
0.13
%
0.21
%
FS: 14
3
.
8
5
0.
5
0
%
6.
9
4
%
3.0
9
%
FS: 144.49
FS: 144
.
5
7
FS: 1
4
3
.
5
0
FS: 144.68
0
.
9
2
%
2.
9
0
%
••••••••
••••••••••••••••••••
••••••
••
••
••
••
••••
••
••
••
••
/
/
/
/
/
/
/
/
/
/
/
/
/
1.
6
8
%
1.
8
5
%
1.
8
2
%
0.
6
2
%
EG:
1
4
3
.
7
5
EG: 1
4
3
.
7
8
EG:
1
4
3
.
7
3
EG: 1
4
3
.
7
2
1.
7
3
%
1.
5
0
%
1.
3
7
%
1.
6
0
%
FS: 143.46 FS: 1
4
3
.
4
7
FS: 143.
4
6
FS: 143.45
FS: 14
3
.
4
5
1.
5
0
%
143.8
8
T
C
143.3
8
F
L
FS: 1
4
4
.
0
0
FS: 1
4
3
.
5
5
6.32%
FS: 143.4
5
EG: 1
4
3
.
6
2
EG: 1
4
3
.
5
0
FS:
1
4
3
.
6
2
FS:
1
4
3
.
5
0
FS: 1
4
3
.
6
3
FS: 1
4
3
.
6
2
FS: 1
4
3
.
6
3
EG:
1
4
3
.
6
3
FS:
1
4
3
.
6
4
EG: 14
3
.
6
4
FS: 143
.
2
1
E
G
:
1
4
3
.
2
1
FS: 143.
4
9
FS: 1
4
3
.
4
8
FS: 1
4
3
.
4
7
FS:
1
4
3
.
4
7
FS: 14
3
.
4
6
FS: 143.
4
4
FS: 143.49
E
G
:
1
4
3
.
4
9
FS: 143.44
EG
:
1
4
3
.
4
4
EG: 1
4
3
.
4
4
EG: 1
4
3
.
5
3
FS: 1
4
3
.
4
9
0.77%0.04%
T
G
:
1
4
3
.
4
4
TG: 1
4
3
.
4
5
TG:
1
4
3
.
4
6
TG: 143.47
FS: 143.47
0.
9
8
%
1.
8
3
%
1.
7
0
%
EG:
1
4
3
.
4
6
FS: 143.52
E
G
:
1
4
3
.
5
2
FS: 143.53
E
G
:
1
4
3
.
5
3
FS: 143.53
E
G
:
1
4
3
.
5
3
FS: 143.
3
5
E
G
:
1
4
3
.
3
5
EG: 1
4
3
.
5
7
0.24%0.16%0.02%
1.
1
2
%
0.09%
0.14%
0.64%
2.
3
1
%
FL: 143.00
FL
:
1
4
2
.
7
8
FILE NAME: 061-118 GRAD.DWG
001020
(IN FEET)
5
GRAPHIC SCALE
1 IN = 10 FT
REFERENCE KEYNOTES
100 SITE IMPROVEMENTS
101 6" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
102 6" CURB & GUTTER PER CITY OF SLO STD DETAIL 4030, SHEET C-6.0
103 CONCRETE SIDEWALK PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0 OVER 24"
CLASS II AGGREGATE BASE
104 WHEEL STOP (48" LENGTH) PER CITY OF SLO STD DETAIL 2260, SHEET C-6.0
105 ACCESSIBLE PARKING STALL STRIPING AND SIGNAGE PER CALTRANS DETAIL
A90A, SHEET C-6.0
106 CURB RAMP PER CALTRANS DETAIL A88A, SHEET C-6.0
107
DETECTABLE WARNING SURFACE PER CALTRANS DETAIL A88A, SHEET C-6.0.
SURFACE SHALL BE YELLOW AND APPROXIMATE FS 33538 OF SAE AMS-STD-595A.
(CBC 11B-705.1.1.3.1).
108 SAWCUT AND REPLACE EXIST ASPHALT PER CITY OF SLO STD DETAIL 4910. NEW 6"
ASPHALT INSTALLATION NOTES PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0
109 TRENCH DRAIN AND CONCRETE ENCASEMENT PER ZURN P6-BDD AND Z886-HD,
SHEET C-6.0 AND DETAIL 1, SHEET C-6.0
110 CURB INLET PER CITY OF SLO STD DETAIL 3350, SHEET C-6.1
111 CONCRETE EDGING (LANDSCAPE CURB), SEE SHEETS SL-1 AND SL-2 FOR DETAIL
112 8" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
113 SINGLE STRIPE PARKING STALLS PER CITY OF SLO STD DETAIL 2250, SHEET C-6.1
114 INSTALL NEW LOG BARRIER PER DETAIL 30, SHEET C-6.1
103
103
103
103
101
102 109
108
107
110
112
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
C
-
3
.
2
A
Scale: 1"=5'
GRADING DETAILA
EXIST
RESTROOM
BUILDING
SEE UTILITY PLAN C-4.0 FOR
STORM DRAIN PROFILE
105 105 105
3.
0
0
'
111
111
104
104 104
MATCHLINE
SEE SHEET C-3.4
103
103
TRENCH FL: 142.78
TRENCH FL: 143.00
44.54 LF @ 0.5%
8.00'9.00'9.00'
113
(TYP.)
104
18
.
0
0
'
9.00'
(TYP.)
18
.
0
0
'
(T
Y
P
.
)
(TYP.)(TYP.)
(T
Y
P
.
)
113
(TYP.)
109
103
103
105105
Page 35 of 57
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••••
••
••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••••
••
••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
145
146
145
143
144
146
1
4
7
145
146
147
1
4
8
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///////////////
///
///
///
///
///
///
///
///
///
///
///
///
///
///
///////////////
//
/
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
FS: 1
4
4
.
7
8
FS: 14
4
.
8
7
FS: 145.
1
6
FS: 14
5
.
2
5
FS: 1
4
5
.
5
4
FS: 14
5
.
6
4
FS: 145.83
FS:
1
4
5
.
9
3
0.47%
0.49%1.
7
2
%
FS: 147
.
2
8
FS: 146
.
6
2
FS
:
1
4
6
.
2
0
FS: 146.27
FS
:
1
4
5
.
6
6
FS: 14
6
.
1
0
FS:
1
4
6
.
1
7
FS: 146.
0
0
FS: 145.72
1.
7
1
%
FS: 146.00
FS: 146
.
6
6
FS: 145.
9
0
4.
1
1
%
1.
6
2
%
1.
4
7
%
FS:
1
4
5
.
6
1
FS: 145.7
8
FS
:
1
4
3
.
2
4
4.27
%
FS: 14
4
.
7
9
FS: 144
.
8
6
FS:
1
4
5
.
8
8
FS:
1
4
6
.
1
5
FS: 146
.
0
4
EG: 145.10
EG: 146.10
EG: 14
6
.
9
6
FS: 14
2
.
2
6
2.
8
1
%
5.
5
8
%
1.0
2
%
1.7
2
%
5.0
3
%
FS: 146.32
FS: 14
5
.
9
7
FS: 1
4
5
.
7
5
1.2
3
%
1.1
2
%
FS: 145
.
5
0
FS: 14
5
.
5
5
FS: 14
5
.
8
9
FS: 145.62
FS: 145.50
FS:
1
4
4
.
9
1
FS: 145.87
001020
(IN FEET)
5
GRAPHIC SCALE
1 IN = 10 FT
REFERENCE KEYNOTES
100 SITE IMPROVEMENTS
101 6" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
102 6" CURB & GUTTER PER CITY OF SLO STD DETAIL 4030, SHEET C-6.0
103 CONCRETE SIDEWALK PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0 OVER 24"
CLASS II AGGREGATE BASE
104 WHEEL STOP (48" LENGTH) PER CITY OF SLO STD DETAIL 2260, SHEET C-6.0
105 ACCESSIBLE PARKING STALL STRIPING AND SIGNAGE PER CALTRANS DETAIL
A90A, SHEET C-6.0
106 CURB RAMP PER CALTRANS DETAIL A88A, SHEET C-6.0
107
DETECTABLE WARNING SURFACE PER CALTRANS DETAIL A88A, SHEET C-6.0.
SURFACE SHALL BE YELLOW AND APPROXIMATE FS 33538 OF SAE AMS-STD-595A.
(CBC 11B-705.1.1.3.1).
108 SAWCUT AND REPLACE EXIST ASPHALT PER CITY OF SLO STD DETAIL 4910. NEW 6"
ASPHALT INSTALLATION NOTES PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0
109 TRENCH DRAIN AND CONCRETE ENCASEMENT PER ZURN P6-BDD AND Z886-HD,
SHEET C-6.0 AND DETAIL 1, SHEET C-6.0
110 CURB INLET PER CITY OF SLO STD DETAIL 3350, SHEET C-6.1
111 CONCRETE EDGING (LANDSCAPE CURB), SEE SHEETS SL-1 AND SL-2 FOR DETAIL
112 8" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
113 SINGLE STRIPE PARKING STALLS PER CITY OF SLO STD DETAIL 2250, SHEET C-6.1
114 INSTALL NEW LOG BARRIER PER DETAIL 30, SHEET C-6.1
103
103
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
C
-
3
.
1
MATCHLINE
SEE SHEET C-3.3
111
111
1114
Page 36 of 57
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••
••
••••
140
139
141
142
143
144
140
139
141
142
140
139
141
142
143
144
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//////
/
/
/
/
/
/
/
/
/
FS: 14
3
.
4
0
FS: 143
.
4
5
4.
1
1
%
FS: 143.1
7FS: 143.22
4.
1
1
%
FS: 141.7
1FS: 141.76
FS: 1
4
0
.
1
9
FS: 1
4
0
.
1
5
0.71%
1.28%
1.52%
F
S
:
1
3
9
.
4
6
FS: 139
.
4
0
FS: 139
.
5
3
FS: 139.59
FS: 140.
8
3
FS: 140.9
2
FS:
1
4
0
.
9
2
FS: 140.7
2
FS
:
1
3
9
.
0
8
FS: 139
.
0
4
FS: 1
3
8
.
0
7
FS:
1
3
8
.
0
4
EG:
1
3
8
.
0
3
EG: 13
7
.
9
1
1.53%
3.
9
1
%
4.
1
4
%
1.64%
1.91%
EG: 1
4
0
.
2
5
EG: 1
4
1
.
8
9
EG: 1
4
3
.
4
3
EG: 143.8
0
0.
9
6
%
FS: 141.33
FS: 140.06
FS: 140.04
0.74%
1.03%
FS: 140.8
0
FS: 140.8
7
FS: 140.9
6
F
S
:
1
4
0
.
7
5
FS: 141.
1
3
2.
6
5
%
FS:
1
4
1
.
6
9
FS: 141.38
FS: 142.1
4
FS:
1
4
1
.
4
1
0.22%
1.1
8
%
4.1
5
%
1.00
%
3.
2
3
%
1.10
%
FS: 138.94
2.
6
4
%
FS: 13
9
.
1
8
FS:
1
3
9
.
6
9
FS: 139
.
6
3
1.15%
1.40%
FS: 1
3
9
.
5
6
FS: 1
3
9
.
4
9
1.
0
0
%
4.27
%
2.
8
1
%
FS: 1
4
0
.
2
2
1.76%
3.
5
5
%
3.
6
6
%
2.
9
3
%
0.50%
EG: 1
3
9
.
5
4
FILE NAME: 061-118 GRAD.DWG
001020
(IN FEET)
5
GRAPHIC SCALE
1 IN = 10 FT
REFERENCE KEYNOTES
100 SITE IMPROVEMENTS
101 6" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
102 6" CURB & GUTTER PER CITY OF SLO STD DETAIL 4030, SHEET C-6.0
103 CONCRETE SIDEWALK PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0 OVER 24"
CLASS II AGGREGATE BASE
104 WHEEL STOP (48" LENGTH) PER CITY OF SLO STD DETAIL 2260, SHEET C-6.0
105 ACCESSIBLE PARKING STALL STRIPING AND SIGNAGE PER CALTRANS DETAIL
A90A, SHEET C-6.0
106 CURB RAMP PER CALTRANS DETAIL A88A, SHEET C-6.0
107
DETECTABLE WARNING SURFACE PER CALTRANS DETAIL A88A, SHEET C-6.0.
SURFACE SHALL BE YELLOW AND APPROXIMATE FS 33538 OF SAE AMS-STD-595A.
(CBC 11B-705.1.1.3.1).
108 SAWCUT AND REPLACE EXIST ASPHALT PER CITY OF SLO STD DETAIL 4910. NEW 6"
ASPHALT INSTALLATION NOTES PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0
109 TRENCH DRAIN AND CONCRETE ENCASEMENT PER ZURN P6-BDD AND Z886-HD,
SHEET C-6.0 AND DETAIL 1, SHEET C-6.0
110 CURB INLET PER CITY OF SLO STD DETAIL 3350, SHEET C-6.1
111 CONCRETE EDGING (LANDSCAPE CURB), SEE SHEETS SL-1 AND SL-2 FOR DETAIL
112 8" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
113 SINGLE STRIPE PARKING STALLS PER CITY OF SLO STD DETAIL 2250, SHEET C-6.1
114 INSTALL NEW LOG BARRIER PER DETAIL 30, SHEET C-6.1
103
103
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
MATCHLINE
SEE SHEET C-3.2
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
C
-
3
.
4
108
111
107
104
104
103
104
Page 37 of 57
••
••
••
••
••
••
•
•
••
••
••
••
••
••
•
•
••
••
••
••
••
•
•
••
••
••
••
••
•
•
•
•
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
135
132
133
134
136
137
135
136
137
138
FS: 14
1
.
4
2
FS: 14
2
.
3
9
FS:
1
3
6
.
6
8
FS: 13
3
.
6
2
FS:
1
3
7
.
4
7
FS: 138.28
FS: 13
9
.
5
1
FS:
1
3
7
.
3
9
FS: 1
4
1
.
0
3
5.07%
5.89%
1
4
0
1
3
9
1
4
1
1
4
2
FILE NAME: 061-118 GRAD.DWG
001020
(IN FEET)
5
GRAPHIC SCALE
1 IN = 10 FT
REFERENCE KEYNOTES
100 SITE IMPROVEMENTS
101 6" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
102 6" CURB & GUTTER PER CITY OF SLO STD DETAIL 4030, SHEET C-6.0
103 CONCRETE SIDEWALK PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0 OVER 24"
CLASS II AGGREGATE BASE
104 WHEEL STOP (48" LENGTH) PER CITY OF SLO STD DETAIL 2260, SHEET C-6.0
105 ACCESSIBLE PARKING STALL STRIPING AND SIGNAGE PER CALTRANS DETAIL
A90A, SHEET C-6.0
106 CURB RAMP PER CALTRANS DETAIL A88A, SHEET C-6.0
107
DETECTABLE WARNING SURFACE PER CALTRANS DETAIL A88A, SHEET C-6.0.
SURFACE SHALL BE YELLOW AND APPROXIMATE FS 33538 OF SAE AMS-STD-595A.
(CBC 11B-705.1.1.3.1).
108 SAWCUT AND REPLACE EXIST ASPHALT PER CITY OF SLO STD DETAIL 4910. NEW 6"
ASPHALT INSTALLATION NOTES PER CITY OF SLO STD DETAIL 4110, SHEET C-6.0
109 TRENCH DRAIN AND CONCRETE ENCASEMENT PER ZURN P6-BDD AND Z886-HD,
SHEET C-6.0 AND DETAIL 1, SHEET C-6.0
110 CURB INLET PER CITY OF SLO STD DETAIL 3350, SHEET C-6.1
111 CONCRETE EDGING (LANDSCAPE CURB), SEE SHEETS SL-1 AND SL-2 FOR DETAIL
112 8" CURB PER CITY OF SLO STD DETAIL 4020, SHEET C-6.0
113 SINGLE STRIPE PARKING STALLS PER CITY OF SLO STD DETAIL 2250, SHEET C-6.1
114 INSTALL NEW LOG BARRIER PER DETAIL 30, SHEET C-6.1
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
MATCHLINE
SEE SHEET C-3.1
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
C
-
3
.
3
111
111
111
Page 38 of 57
••
••
••
••
••
••
••
••
••
••
••
•
•
•
•
•
•
••
••
••
•
•
••
••
••
•
•
••
•
•
••
••
••
••
••
••
••
••
••
••
••••••••••••
••
••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••
••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••••••••••••••••••••••••••
••
••••
••
••
••
••
••
••
••
••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
I
R
R
IR
R
I
R
R
I
R
R
IR
R
I
R
R
IRR
IR
R
IR
R
IR
R
IR
R
IR
R
IR
R
WL
WL
WL
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//
/
//
/
/
/
///
///
///
///
///
///
///
///
/////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
/
/
/
/
/
/
////////////////////////
/
/
/
/
/
/
SS
WL
WL
WL
WL
WL
SS
SS
1+11
0+00
1+00
SD
SSSSSSSSSSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
WLWLWL
W
L
W
L
W
L
W
L
W
L
W
L
ELEELEELE
EL
E
V
A
T
I
O
N
EL
E
V
A
T
I
O
N
STATION
135
140
150
135
140
150
0+00 0+20 0+40 0+60 0+80 1+00 1+11
12" HDPE SD
3.04 LF @ 0.50% SLOPE
12" HDPE SD
3.78 LF @ 0.50% SLOPE EXIST 8" PVC SD
27.13 LF @ 4.61% SLOPE
CURB INLET 1
STA: 0+04.12
TG=143.89
FL(IN)=142.64(NW)
FL(OUT)=141.28(SW)
EXIST 24x24 SD INLET 2
STA: 0+83.21
TG=142.43
FL(IN)=140.46(SE)
FL(OUT)=140.46(NW)
12" HDPE SD
72.26 LF @ 1.08% SLOPE
ST
A
:
0
+
0
7
.
1
6
ST
A
:
0
+
1
0
.
9
5
FL
E
L
E
V
:
1
4
3
.
3
8
FILE NAME: 061-118 UTIL.DWG
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
NOTE:
EXIST UTILITY LOCATIONS ARE APPROXIMATE LOCATIONS PER CITY OF SAN
LUIS OBISPO AS-BUILT DRAWINGS. CONTRACTOR SHALL ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR LOCATING OR HAVING LOCATED ALL
UNDERGROUND UTILITIES AND RELATED FACILITIES AND FOR PROTECTING
SAME DURING THE COURSE OF CONSTRUCTION
EXIST 8" WL
EXIST 6" SS
EXIST IRR LINE
EXIST IRR LINE
1" WATER SERVICE
EXIST
RESTROOM
BUILDING
1" WATER SERVICE
1" WATER
SERVICE
REFERENCE KEYNOTES
400 UTILITIES
401 WATER SERVICE LINE AND CONNECTION PER CITY OF
SLO STD DETAIL 6210, SHEET C-6.1
402 SEWER LATERAL AND CONNECTION PER CITY OF SLO
STD DETAIL 6810, SHEET C-6.1
401
402
401
401
Scale: 1"= 10'
STORM DRAIN1
00
1"
3.75
2.5
1.25
5
CONNECTION PER CITY OF
SLO STD DTL 3540, SHEET C-6.1
CONNECTION PER CITY OF
SLO STD DTL 3540, SHEET C-6.1
CASE A CONNECTION PER CITY OF
SLO STD DTL 3540, SHEET C-6.1
EXIST 8" WL
FGEG
SHALLOW TRENCH PER
COUNTY OF SLO STD DTL
U-4B, SHEET C-6.1
4" SEWER LATERAL
@ 2% W/ BALL VALVE
SEDIMENT BOX
SEE SHEET C-3.1 FOR
STORM DRAIN DETAIL
4" SEWER LATERAL
@ 2% W/ BALL VALVE
SEDIMENT BOX
4" SEWER LATERAL
@ 2% W/ BALL VALVE
SEDIMENT BOX
402
IRRIGATION SLEEVES UNDER
SIDEWALK (TYP.). SEE SHEETS
IP-1 AND IP-2 FOR DETAIL
IRRIGATION POINT
OF CONNECTIONEXIST
ELECTRICAL LINE
402
Page 39 of 57
••
••
••
••
••
••
••
••
••
••
••
•
•
••
••
•
•
••
••
••
•
•
••
••
••
••
••
••
•
•
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••
••
••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••
••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••••••••••••••••••••••••••
••
•
•
•
•
••
••
••
••
••
••
••
••
••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
135
140
1
4
5
145
136
137
138
139
141
142
143
144
140
145
139
141
142
143
144
146
147
148
140
145
139
141
142
143
144
146
140
145
139
141
142
143
144
146
147
1
4
8
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//
/
/
/
/
/
/
/
/
/
///////////////
///
///
///
///
///
///
////////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
////////////////////////
///
///
///
///
///
///////////////////
//
///
//////
/
/
/
//////
/
/
/
/
//
//////////////////
//////
/
/
/
/
/
/
O/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/HO/H
O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H O/H
SD
135
140
145
133
1
3
4
136
137
138
139
141
142
143
144
146
SD
14
5
146
147
147
FILE NAME: 061-118 EROS.DWG
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
502
••
••
•••
504
REFERENCE KEYNOTES
TEMPORARY EROSION CONTROL
501 FIBER ROLL PER CALTRANS BMP SC-5 AND T56, SHEET C-5.1
502 TEMPORARY DRAINAGE INLET PROTECTION TYPE 3A - GRAVEL
BAG BERM PER CALTRANS BMP SC-10 AND T62, SHEET C-5.1
503 TEMPORARY CONSTRUCTION ENTRANCE PER CALTRANS T58,
SHEET C-5.1
504 TEMPORARY CONSTRUCTION WASHOUT FACILITY PER CALTRANS
T59, SHEET C-5.1
505 CONSTRUCTION STAGING AREA
501
FRFRFFF
FRFRFF
FRF
777777777
F
R
F
R
F
R
FR
FR
FR
FRFRFRFRFRFRFR
FR
FR
FR
FRFRF
FR
FR
FRFR
FR
FR
FR
/////
////
SSD
/
/
/
/
//
/
//
/
/
///
502
503
FRRF
FRFR
FRRRFR
FRFR
FRFR
FRFFR
FRFR
F
R
F
R
F
R
FR
FRFRFR14147
FR
FR
FR FR FR FR FR FR
FR
F
R
F
R
F
R
R
FRFRR
FR
FR
F
R
F
R
F
R
F
R
F
R
FR
FR
FR
FR
F
R
F
R
R
F
R
F
R
F
R
F
FR
FR
FR
FR
FR
FR
F
R
F
R
F
R
F
R
F
R
FR
FR
FRRRFR
FRRFR
FRR141141141141141
FRFRF
FR
FR
FR FRRF FR FR 111
FRF
FR
FR
FR
FR
FR
FR
FR FR FR
FR
FRFR
FR
FR FR FR FR FR FR FRFF FR FR
FR
FR
FR
(TYP.)
FR
505
•
F
R
F
R
FR
F
R
FR
FR
FR
FR
FR
FR
FRFR
FRFR
FR
FR
FR
FR
FR
FR FR FR FR
FR FR
FRF
FR
FRFRRRRRRRRRRFRFFFFFFFFRRRRFFFFFRRRRFFFRRRRFFFFRRRRRRRRRRRRRRRRRRRFFRRRRRFFFFFFFFFFFFFFFFFFR
FRFRFRRFRFR
F
R
R
F
R
F
R
FR
FRF
FRFR
FR
F
R
F
R
FR
FRF••
FR
FR
LIMITS OF DISTURBANCE
FRF
FR
FR
FRFFF
Page 40 of 57
FILE NAME: 061-118 EROS.DWG
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
GENERAL NOTES
1. CALTRANS CONSTRUCTION SITE BEST
MANAGEMENT PRACTICES (BMP) MANUAL
(DATED MAY 2017) "FACT SHEETS" SHOWN ON
THIS SHEET ARE FOR REFERENCE ONLY.
2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
REFER TO ORIGINAL CALTRANS
CONSTRUCTION SITE BMP MANUAL (MAY
2017) FOR ENTIRE "FACT SHEET"
INFORMATION AND DOCUMENTATION.
Scale: N.T.S.
CONSTRUCTION STAGING AREA505
FR
FR
CONSTRUCTION
EQUIPMENT PARKING
INSTALL PERIMETER FIBER
ROLLS OR SILT FENCING
CONSTRUCTION TRAILER AREA
FUEL STORAGE/HAZ MAT
AREA WITH SECONDARY
CONTAINMENT
CONSTRUCTION
TRASH/RECYCLING
CONCRETE/PAINT
WASHOUT
STOCKPILE AREA
Page 41 of 57
4.00'
2.
7
5
'
FILE NAME: 061-118 CDET.DWG
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
** CONCRETE OVER
24" COMPACTED
NON-EXPANSIVE
MATERIAL. CAN
INCLUDE 6"
AGGREGATE BASE
**
**
** 8" CURB WHERE
NOTED ON PLANS
**
CLASS 3 CONCRETE
PER CITY STANDARDS
24" NON EXPANSIVE MATERIAL
UNDER CONCRETE (CLASS II BASE)
SLOPE CONCRETE
TO DRAINSLOPE CONCRETE
TO DRAIN
ASPHALTCONCRETE
#4 BARS VERT @ 24" MIN
#4 BARS HORZ ON EACH SIDE
(REBAR TO BE 2" CLR OF SURFACE)
Scale: NTS
CONCRETE ENCASEMENT DETAIL1
Page 42 of 57
FILE NAME: 061-118 CDET.DWG
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
BDH
CPK
BDH
12/21/2023
LOG
SD SD
4" PVC
CONNECTION
4" PVC
CONNECTION
*WATER METER AND
APPURTENANCES NOT
TO BE INSTALLED
*ADAPT FROM HDPE TO
BALL VALVE TO PVC
Page 43 of 57
••
••
••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••
••
••
••
•
•
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•
•
•
•
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
/
//
/
/
/
/
/
/
/////////////////////
///
///
//////////////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
////////////////////////
///
///
///
//////////////////
////
//
///
O/HO/HO/HO/HO/HO/HO/H
O/H O/H O/H O/H O/H O/H O/H O/H O/H
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
FILE NAME: 0061-0118 SITE.DWG
702
702
701
504
504
504
701
701
701
701
506
703
REFERENCE KEYNOTES
DESCRIPTION
500 SURFACE IMPROVEMENTS
501 EXPANSION JOINTS AT 100' INTERVALS (EXCEPT WHERE SHOWN OR NOTED
OTHERWISE), SEE DETAIL 4110, SHEET C-6.0
502 WEAKENED PLANE JOINTS: 20' O.C. SPACING (EXCEPT WHERE SHOWN OR
NOTED OTHERWISE) SEE DETAIL 4110, SHEET C-6.0
503 SCORE MARKS AT 5' INTERVALS (EXCEPT WHERE SHOWN OR NOTED
OTHERWISE), SEE DETAIL 4110, SHEET C-6.0
504 CONCRETE SIDEWALK: SEE DETAIL 4110, SHEET C-6.0
505 CONCRETE EXPANSION CONTROL: SEE DETAIL 4110, SHEET C-6.0
506 CONCRETE EDGING, SEE DETAIL 8710, SHEET SD-3
507 8" CONCRETE CURB: SEE DETAIL 4020, SHEET C-6.0
508 EXISTING LANDSCAPE BOULDERS-RELOCATED:
600 SITE FURNISHINGS
601 RECTANGULAR SHADE SAIL: SEE DETAILS 2-4, SHEET SD-1, ENLARGEMENT A,
SHEET SL-3, AND SPECIAL PROVISIONS
602 TRIANGULAR SHADE SAIL: SEE DETAILS 1,4,5 SHEET SD-1, ENLARGEMENT B,
SHEET SL-4, AND SPECIAL PROVISIONS
603 RECTANGULAR SHADE SAIL: SEE DETAILS 2-4, SHEET SD-1, ENLARGEMENT C,
SHEET SL-3, AND SPECIAL PROVISIONS
604 RECTANGULAR SHADE SAIL: SEE DETAILS 2-4, SHEET SD-1, ENLARGEMENT D,
SHEET SL-3, AND SPECIAL PROVISIONS
605 RELOCATE EXISTING BLUE PLASTIC TRASH RECYCLE RECEPTACLE, SEE REF.
NOTE 202, SHEET C-1.2
606 RELOCATE EXISTING CONCRETE TRASH RECEPTACLE WITH FOUR-WAY METAL
LID, SEE REF. NOTE 202, SHEET C-1.2
607 EXISTING PET STATION AND SIGN-RELOCATED, SEE DETAIL 3, SHEET SD-3
608 DRINKING FOUNTAIN AND DOG WATER STATION: SEE DETAIL 1, SHEET SD-3
700 SITE IMPROVEMENTS
701 4' CHAINLINK FENCE WITH BLACK VINYL COATING: SEE DETAIL 2, SHEET SD-2
702 DOG PARK DOUBLE ENTRY GATE: SEE DETAIL 3, SHEET SD-2
703 CHAINLINK MAINTENANCE GATE: SEE DETAIL 1, SHEET SD-2
704 4' CHAINLINK FENCE WITH CONCRETE CURB: SEE DETAIL 4020, SHEET C-6.0
XXX
MCC
EAS
DALIDIO
PA
PA
PA
504
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
S
L
-
2
SLB
502
503
TYP
TYP
502
503
TYP
TYP
PA
PA
LIMIT OF W
O
R
K
LIMIT OF WORK
LI
M
I
T
O
F
W
O
R
K
506
501
501 501
701
701
703
504
702
701
701
502
503
TYP
TYP
606
607
506
501
A
SL-3
B
SL-4
C
SL-3
509
509
601
602
603
501
501
501
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
608
608
608
Page 44 of 57
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
•
•
•
•
••
•
•
••
••
••
••
••
••
••
••
••
••
••••••••••••
••
••
••
••
••••••
••
••••••••••••••••••••••••••
••
••••
••
••••
//////////////////
/
/
/
/
//
///
///
/
/
/
//////
/
/
/
/
//
/////////
///
//////
//////
/
/
/
/
/
/
O/HO/HO/HO/HO/H
O/H O/H O/H O/H O/H
SD
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
FILE NAME: 0061-0118 SITE.DWG
504
504
509
702
702
701
704
REFERENCE KEYNOTES
DESCRIPTION
500 SURFACE IMPROVEMENTS
501 EXPANSION JOINTS AT 100' INTERVALS (EXCEPT WHERE SHOWN OR NOTED
OTHERWISE), SEE DETAIL 4110, SHEET C-6.0
502 WEAKENED PLANE JOINTS: 20' O.C. SPACING (EXCEPT WHERE SHOWN OR
NOTED OTHERWISE) SEE DETAIL 4110, SHEET C-6.0
503 SCORE MARKS AT 5' INTERVALS (EXCEPT WHERE SHOWN OR NOTED
OTHERWISE), SEE DETAIL 4110, SHEET C-6.0
504 CONCRETE SIDEWALK: SEE DETAIL 4110, SHEET C-6.0
505 CONCRETE EXPANSION CONTROL: SEE DETAIL 4110, SHEET C-6.0
506 CONCRETE EDGING, SEE DETAIL 8710, SHEET SD-3
507 8" CONCRETE CURB: SEE DETAIL 4020, SHEET C-6.0
508 EXISTING LANDSCAPE BOULDERS-RELOCATED:
509 CONCRETE PLAZA/FLATWORK - SEE DETAIL 4110, SHEET C-6.0
600 SITE FURNISHINGS
601 RECTANGULAR SHADE SAIL: SEE DETAILS 2-4, SHEET SD-1, ENLARGEMENT A,
SHEET SL-3, AND SPECIAL PROVISIONS
602 TRIANGULAR SHADE SAIL: SEE DETAILS 1,4,5 SHEET SD-1, ENLARGEMENT B,
SHEET SL-4, AND SPECIAL PROVISIONS
603 RECTANGULAR SHADE SAIL: SEE DETAILS 2-4, SHEET SD-1, ENLARGEMENT C,
SHEET SL-3, AND SPECIAL PROVISIONS
604 RECTANGULAR SHADE SAIL: SEE DETAILS 2-4, SHEET SD-1, ENLARGEMENT D,
SHEET SL-3, AND SPECIAL PROVISIONS
605 RELOCATE EXISTING BLUE PLASTIC TRASH RECYCLE RECEPTACLE, SEE REF.
NOTE 202, SHEET C-1.2
606 RELOCATE EXISTING CONCRETE TRASH RECEPTACLE WITH FOUR-WAY METAL
LID, SEE REF. NOTE 202, SHEET C-1.2
607 EXISTING PET STATION AND SIGN-RELOCATED, SEE DETAIL 3, SHEET SD-3
608 DRINKING FOUNTAIN AND DOG WATER STATION: SEE DETAIL 1, SHEET SD-3
700 SITE IMPROVEMENTS
701 4' CHAINLINK FENCE WITH BLACK VINYL COATING: SEE DETAIL 2, SHEET SD-2
702 DOG PARK DOUBLE ENTRY GATE: SEE DETAIL 3, SHEET SD-2
703 CHAINLINK MAINTENANCE GATE: SEE DETAIL 1, SHEET SD-2
704 4' CHAINLINK FENCE WITH CONCRETE CURB: SEE DETAIL 4020, SHEET C-6.0
XXX
508
703
502
503
TYP
TYP
LIMIT OF WOR
K
LIMIT OF WORK
LI
M
I
T
O
F
W
O
R
K
507
605606607
701
506
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
S
L
-
1
SD-24&5
EXISTING CONCRETE -
PROTECT IN PLACED
SL-3
D
SL-3 604
MCC
EAS
SLB
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
701
TYP
Page 45 of 57
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
FILE NAME: 0061-0118 SITE.DWG
SCALE: 1" = 2 FTENLARGEMENT A
3-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
1-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
2-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
4-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
18.00'
14
.
5
0
'
14••••••••••••••••••••••••••••
TYP. AT
PERIMETER
11'-6"
11'-6"
8'-0"
8'-0"
SCALE: 1" = 2 FTENLARGEMENTC
20.00'
12
.
5
0
'
2-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
1-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
3-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
3-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
14••••••••••••••••••••••••••••
TYP. AT PERIMETER
COMMERCIAL NINETY FIVE
340 FR HDPE SHADE FABRIC
COLOR SKY BLUE 495626
COMMERCIAL NINETY FIVE
340 FR HDPE SHADE FABRIC
COLOR STEEL GREY 495718
11'-6"
11'-6"
8'-0"
8'-0"
ENLARGEMENT D (TYPICAL OF TWO)SCALE: 1" = 2 FT
7.
0
0
'
13.00'
COMMERCIAL NINETY FIVE
340 FR HDPE SHADE FABRIC
COLOR SKY BLUE 495626
3-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
5-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
1-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
4-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
2-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
6-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
13.00'
14••••••••••••••••••••••••••••
TYP. AT PERIMETER
11'-6"
11'-6"11'-6"
8'-0"
8'-0"
8'-0"
20.50'
22.50'
20
.
0
0
'
17
.
0
0
'
15
.
0
0
'
10
.
7
5
'
MCC
EAS
SLB
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FLAME RETARDANT SHADE
SAIL FABRIC, COLOR SKY
BLUE 495626
COMMERCIAL NINETY FIVE
340 FR HDPE SHADE FABRIC
COLOR STEEL GREY 495718
NOTE:
ALL STEEL POSTS TO HAVE A WELDED CAP TO MATCH.
Page 46 of 57
8'-0"
SCALE: 1" = 2 FT
14••••••••••••••••••••••••••••
TYP. AT PERIMETER
COMMERCIAL NINETY FIVE
340 FR HDPE SHADE FABRIC
COLOR STEEL GREY 495718
ENLARGEMENT B
11'-6"
1-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
2.02'
TYP
OF
ALL
18
.
0
0
'
10
.
0
0
'
12.00'
12
.
0
0
'
2.
0
0
'
8'-0"
8'-0"
11'-6"
3-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
2-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (8'-0" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
4-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
5-STL PIPE 5.563XSCH40
ASTM A500/A500M-10a
Gr. B. Fy=42 KSI
COLUMNS (11'-6" AFF)
••••••••••••••••••••••••••••••••••••••••••••••••••••
2500 PSI CONCRETE FOOTING
30.00'
24
.
5
0
'
30
.
0
0
'
MCC
EAS
SLB
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
COMMERCIAL NINETY FIVE
340 FR HDPE SHADE FABRIC
COLOR SKY BLUE 495626
NOTE:
ALL STEEL POSTS TO HAVE A WELDED CAP TO MATCH.
Page 47 of 57
SECTION 3105 AWNINGS AND CANOPIES NOTES:
1. 3105.1 GENERAL. AWNINGS OR CANOPIES SHALL COMPLY WITH THE REQUIREMENTS OF THIS
SECTION AND OTHER APPLICABLE SECTIONS OF THIS CODE.
2. 3105.2 DEFINITION. THE FOLLOWING TERM SHALL, FOR THE PURPOSES OF THIS SECTION AND
AS USED ELSEWHERE IN THIS CODE, HAVE THE MEANING SHOWN HEREIN.
3. 3105.3 DESIGN AND CONSTRUCTION. AWNINGS AND CANOPIES SHALL BE DESIGNED AND
CONSTRUCTED TO WITHSTAND WIND OR OTHER LATERAL LOADS AND LIVE LOADS AS
REQUIRED BY CHAPTER 16 WITH DUE ALLOWANCE FOR SHAPE, OPEN CONSTRUCTION AND
SIMILAR FEATURES THAT RELIEVE THE PRESSURES OR LOADS. STRUCTURAL MEMBERS
SHALL BE PROTECTED TO PREVENT DETERIORATION. AWNINGS SHALL HAVE FRAMES OF
NONCOMBUSTIBLE MATERIAL, FIRE-RETARDENT-TREATED WOOD, WOOD OF TYPE IV SIZE, OR
1-HOUR CONSTRUCTION WITH COMBUSTIBLE OR NONCOMBUSTIBLE COVERS AND SHALL BE
EITHER FIXED, RETRACTABLE, FOLDING OR COLLAPSIBLE.
4. 3105.4 CANOPY MATERIALS. CANOPIES SHALL BE CONSTRUCTED OF A RIGID FRAMEWORK
WITH AN APPROVED COVERING THAT MEETS THE FIRE PROPAGATION PERFORMANCE
CRITERIA OF NFPA 701 OR HAS A FLAME SPREAD INDEX NOT GREATER THAN 25 WHEN
TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. ALL FABRICS AND ALL INTERIOR
DECORATIVE FABRICS OR MATERIALS SHALL BE FLAME RESISTANT IN ACCORDANCE WITH
APPROPRIATE STANDARDS SET FORTH IN CCR, TITLE 19, DIVISION 1, CHAPTER 8. TOPS AND
SIDEWALLS SHALL BE MADE EITHER FROM FABRIC WHICH HAS BEEN FLAME RESISTANT
TREATED WITH AN APPROVED EXTERIOR CHEMICAL PROCESS BY AN APPROVED
APPLICATION CONCERN, OR FROM INHERENTLY FLAME RESISTANT FABRIC APPROVED AND
LISTED BY THE STATE FIRE MARSHAL (SEE CCR, TITLE 19, DIVISION 1, CHAPTER 8).
5. 3202.2.3 AWNINGS. THE VERTICAL CLEARANCE FROM THE PUBLIC RIGHT-OF-WAY TO THE
LOWEST PART OF ANY WANING, INCLUDING VALANCES, SHALL BE 7 FEET (2134 MM) MINIMUM.
GENERAL NOTES:
1. ALL AWNINGS AND CANOPIES SHALL CONFORM TO SECTION 3105.
2. ALL FOOTING AND MEMBER SIZING FOR SHADE SAILS ARE PER MANUFACTURER AND
STRUCTURAL ENGINEER CALCULATIONS.
3. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO OWNER REP AND LANDSCAPE ARCHITECT
FOR REVIEW PRIOR TO FABRICATION.
4. ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST EDITION OF LOCAL BUILDING CODE OR
THE 2022 EDITION OF THE CALIFORNIA BUILDING CODE, WHICHEVER IS MORE STRICT.
5. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS, CONDITIONS, NOTES, AND
SPECIFICATIONS AT JOB SITE AND SHALL REPORT ANY ERRORS, OMISSIONS OR
DISCREPANCIES PRIOR TO BID AND START WORK TO PROJECT ARCHITECT AND/OR
ENGINEERS.
6. DETAILS OF CONSTRUCTION NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED IN
ACCORDANCE WITH DETAILS SHOWN FOR SIMILAR CONDITIONS AND MATERIALS.
7. ALL WELDING DONE AT CERTIFIED WELDING MANUFACTURER.
8. IF CERTAIN INFORMATION IS NOTED ON THE PLANS OR ONLY IN THE SPECIFICATIONS, THEN
THAT INFORMATION WILL BE AS VALID AS IF NOTED ON BOTH PLANS AND SPECIFICATIONS.
9. DO NOT SCALE DRAWINGS. NOTED SCALES ARE FOR GENERAL REFERENCE ONLY.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE AND SHALL NOT RELY SOLELY
ON SCALING FOR BIDDING PURPOSES. VERIFY ALL NOTED SCALES MATCH FIELD CONDITIONS
PRIOR TO PROCEEDING. NOTED DIMENSIONS SHALL TAKE PRECEDENCE. IF DISCREPANCIES
EXIST, LARGE SCALE DETAILS GOVERN OVER SMALL.
10. DIMENSIONS ARE SHOWN TO FINISH FACE, COLUMN, GRID, AND FACE OF CONCRETE
MASONRY WALLS, UNLESS OTHERWISE NOTED.
SHADE SAIL FOOTING IN MULCH
2
3"
30"
1"
1%
PE
R
G
E
O
T
E
C
H
A
N
D
M
A
N
U
F
A
C
T
U
R
E
R
LEGEND:
A. BASE PREPARATION AND
REINFORCING ARE SHOWN FOR BID
PURPOSES ONLY. VERIFY
REQUIREMENTS OF THE SOILS
REPORT AND COMPLY.
B. FOOTING TO BE DESIGNED USING A
MAX. ALLOWABLE BEARING
CAPACITY OF 2000 PSI DEAD PLUS
LIVE LOADS.
C. SEE LANDSCAPE LAYOUT PLAN FOR
LOCATIONS.
D. FINAL DETAILING OF THE FOOTING
SHALL BE PER THE SHADE SAIL
MANUFACTURER.
NOTES:
14
5
3
6
FC=2500 PSI CONCRETE SHALLOW
FOOTING, MIN. 1% SLOPE
1
FINISH GRADE2
COMPACTED SUBGRADE PER SOILS
ENGINEER'S REPORT
3
STEEL SHADE SAIL POST WITH DARK
GREEN POWDER COATING PER PLAN
4
BARK MULCH, SEE PLANTING NOTES5
3" DOBIE CONCRETE BLOCK6
SHADE SAIL FOOTING IN MULCH
3"
48
"
-
F
O
R
B
I
D
P
U
R
P
O
S
E
S
O
N
L
Y
1
LEGEND:
1
2
A. PAVING THICKNESS, BASE
PREPARATION AND REINFORCING
ARE SHOWN FOR BID PURPOSES
ONLY. VERIFY REQUIREMENTS OF
THE SOILS REPORT AND COMPLY.
B. FOOTING TO BE DESIGNED USING A
MAX. ALLOWABLE BEARING
CAPACITY OF 2000 PSI DEAD PLUS
LIVE LOADS
C. SEE LANDSCAPE LAYOUT PLAN FOR
LOCATIONS.
D. FINAL DETAILING OF THE FOOTING
SHALL BE PER THE SHADE SAIL
MANUFACTURER
4"
5
24
"
4
6
7
NOTES:
CONCRETE PAVING1
FINISH GRADE2
COMPACTED SUBGRADE PER SOILS
ENGINEER'S REPORT
3
STEEL SHADE SAIL POST WITH DARK GREEN
POWDER COATING PER PLAN
4
COMPACTED CLASS II BASE5
SIKAFLEX (OR EQUIVALENT) JOINT SEALANT6
EXPANSION JOINT7
MIN 12"
SHADE SAIL FOOTING IN CONCRETE
30"
8
3" DOBIE CONCRETE BLOCK8
9
FC=2500 PSI CONCRETE SHALLOW FOOTING9
PE
R
G
E
O
T
E
C
H
A
N
D
M
A
N
U
F
A
C
T
U
R
E
R
3
5
48
"
-
F
O
R
B
I
D
P
U
R
P
O
S
E
S
O
N
L
Y
2
RECTANGULAR SHADE SAIL ELEVATION
VARIES
1 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
1
STEEL SHADE SAIL POST PER PLAN2
2
LEGEND:
3
FOOTING, SEE DETAIL THIS SHEET3
3 SHADE SAIL ATTACHMENT
1
1
2
2
3 4
56
6
POST PER PLAN1
1/2" • •••A325, LOCK WASHER2
3
4
5
1/2"• •••••••••••••• •••••••••••••••••••••••••
BOLT (MIN 10 KIPS PROOF
STRENGTH)
63
9/16" • •••HOLE THROUGH
4
CABLE CLAMPS
5
CABLE AT PERIMETER PER PLAN
LEGEND:
4 TRIANGULAR SHADE SAIL ELEVATION
VARIES
1 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
1
STEEL SHADE SAIL POST PER PLAN2
2
VARIES
LEGEND:
3
FOOTING, SEE DETAIL THIS SHEET3
5
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FILE NAME: 0061-0118 SITE-DETL.DWG
MCC
EAS
SLB
Page 48 of 57
HARDSCAPE NOTES:
1. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR FENCES,
GATES, HARDWARE, & ASSEMBLIES.
2. ALL METAL FENCE COMPONENTS SHALL BE GALVANIZED STEEL
WITH BLACK VINYL COATING.
3. COMPACT SURFACE BELOW FOOTINGS TO 90% RELATIVE
COMPACTION.
4' CHAIN-LINK FENCE
ELEVATION
2-1/2" DIA. END POST1
END CAP2
2" DIA. TOP RAIL3
TENSION BAR4
2" DIA. FENCE POST5
RAIL-THRU TOP CAP6
CHAIN LINK FABRIC7
BOTTOM TENSION WIRE8
CONCRETE FOOTING9
COMPACTED SUBGRADE10
FINISH GRADE11
LEGEND:
4 3
5
6
7
8
10
11
1
2
9
10' MAX SPACING
12" MAX
12
3/8" STEEL TENSION ROD W/
TIGHTENER AT ALL CORNERS12
13
ADD SIKAFLEX (OR EQUIVALENT)
JOINT SEALANT AT POST LOCATIONS
13
2
6'6'
4' CHAIN-LINK MAINTENANCE GATE
12'
1
1
2
2
2
LEGEND:
3
2
2
2
3
3
44
445 5
6
7
8
9
10
11
6
NOTES:
A. CITY WILL PROVIDE LOCK.
B. ALL METAL FENCE COMPONENTS SHALL BE
GALVANIZED STEEL WITH BLACK VINYL
COATING.
C. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS.
D. SEE SPECIFICATIONS FOR MORE INFORMATION.
3 3
12"
12
3" GALV. GATE POST1
2" TOP & BOTTOM RAILS2
TENSION BARS3
CHAIN LINK FABRIC4
TENSION BAR STRAPS5
CONCRETE FOOTING, COMPACT BELOW @ 90%
GRAVEL
6
LATCH ASSEMBLY7
SUBGRADE8
CANE BOLT9
CANE BOLT SLEEVE10
FINISH GRADE OR SURFACE11
ADD SIKAFLEX (OR EQUIVALENT) JOINT
SEALANT AT POST LOCATIONS
12
1
NOTES:
A. ALL FENCE MATERIAL SHALL BE GALVANIZED STEEL WITH BLACK VINYL
COATING
B. SEE LANDSCAPE LAYOUT PLAN FOR LOCATIONS.
C. CONTRACTOR TO SUBMIT SHOP DRAWINGS.
D. SEE SPECIFICATIONS FOR MORE INFORMATION.
4' CHAIN-LINK FENCE WITH CONCRETE CURB
1
2
3
4
5
6
7
8
9
10' MAX
1011
12
13
LEGEND:
12" MIN
14
2-1/2" DIA. CORNER & END POST1
END CAP AND BRACE BAND2
1-5/8" DIAMETER TOP RAIL3
TENSION BAR4
2" DIAMETER FENCE POST5
RAIL-THRU TOP CAP6
CHAIN LINK FABRIC7
BOTTOM TENSION WIRE8
HOG TIES AT 12" O.C.9
CONCRETE FOOTING: SEE 8" CONCRETE CURB DETAIL, THIS PAGE10
COMPACTED SUBGRADE11
CONCRETE CURB SEE DETAIL 4220, SHEET C-6.012
FINISH GRADE13
ADD SIKAFLEX (OR EQUIVALENT) JOINT SEALANT AT POST LOCATIONS14
15
3/8" STEEL TENSION ROD W/ TIGHTENER AT ALL CORNERS15
4
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FILE NAME: 0061-0118 SITE-DETL.DWG
MCC
EAS
SLB
4'-0"
LEGEND:
DOG PARK DOUBLE ENTRY GATE
1
2
3
4
5
89
8 ••
••
••
••
••
••
PLAN
6'
10
10
5
6
12
13
NOTES:
A. ALL FENCE MATERIAL SHALL
BE GALV. STEEL WITH BLACK
VINYL COATING.
B. SEE LANDSCAPE LAYOUT PLAN
FOR LAYOUT.
C. CONTRACTOR TO SUBMIT
SHOP DRAWINGS.
D. SEE SPECIFICATIONS FOR
MORE INFORMATION.
14
14 15
2 1/2" GALV. GATE POST1
2" TOP & BOTTOM RAILS2
TENSION BARS3
CHAIN LINK FABRIC4
TENSION BAR STRAPS5
CONCRETE FOOTING6
90% COMPACTED SUBGRADE OR
PAVEMENT
8
FINISH GRADE OR SURFACE9
GATE10
SEE DETAIL FOR CHAINLINK FENCE12
ADD SIKAFLEX (OR EQUIVALENT)
GROUT
13
TIGER COMPACT HINGE, SEE
SPECIFICATIONS
14
10" GALVANIZED STEEL KICK
PLATE, SEE SPECIFICATIONS
15
7
LOCINOX GATE LOCK/LATCH, SEE
SPECIFICATIONS
7
3
Page 49 of 57
EXISTING LANDSCAPE BOULDERS
1
2
LEGEND:
NOTES:
A. DEPRESS BOULDER MASS
13 TO 12 BELOW GRADE AS SHOWN.
B. SEE LANDSCAPE LAYOUT PLAN FOR LOCATIONS.
C. BOULDER GROUPINGS SHALL BE VARYING SIZES.
D. BOULDERS TO BE SELECTED & COORDINATED WITH CITY
REPRESENTATIVE IN THE FIELD.
EXISTING BOULDERS FROM SITE1
COMPACTED SUBGRADE2
2
LEGEND:
DRINKING FOUNTAIN & DOG WATER STATION
NOTES:
A. INSTALL PER MANUFACTURER'S
HARDWARE INSTRUCTIONS.
B. SEE LANDSCAPE LAYOUT PLAN FOR
LOCATIONS
C. SEE CIVIL PLANS FOR UTILITY AND
DRAINAGE INTERFACES
1
2
3 4 56
7 8
20"
DRINKING FOUNTAIN, SEE MANUFACTURER
SPECIFICATIONS
1
CONCRETE PAVING2
PVC DRAIN LINE, SEE CIVIL PLANS3
WATER SUPPLY, SEE CIVIL PLANS4
1" BRASS GATE VALVE, SEE SPECIFICATIONS5
1" TEE W/ PLUG FOR DRAIN DOWN6
6" ROUND PVC CLEANOUT IN BOX7
12" X 18" CONCRETE VALVE BOX W/
LOCKING LID
8
9
30"W x 19"D ADA CLEARANCE AREA9
1
PLAN VIEW
10
DOG DRINKING FOUNTAIN10
1
ELEVATION
1"
RELOCATED PET STATION
8"
3"
LEGEND1
2
3
5 6
7
4
EXISTING PET SIGN1
1.75" x 2" 14 GAUGE QUICK PUNCH
POST
3
P.C. CONCRETE4
AGGREGATE BASE5
NATIVE SOIL6
PITCH SURFACE TO DRAIN7
3
4
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FILE NAME: 0061-0118 SITE-DETL.DWG
MCC
EAS
SLB
Page 50 of 57
••
••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•
•
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
•••
••••••••
•••
•
/
//
/
/
/
/
/
/
/////////////////////
///
///
//////////////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
////////////////////////
///
///
///
//////////////////
////
//
///
O/HO/HO/HO/H
O/H O/H O/H O/H O/H O/H O/H O/H O/H
•••
•
•
•••••••
••••
•••
•
•••
•
••••
••••
WL
WL
WL
SS
WL
WL
WL
WL
WL
SS
SS
SSSSSSSSSS
S
S
S
S
S
S
S
S
S
S
E
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
DALIDIO
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
P
P
-
2
NOTES:
1. QUANTITIES SHOWN ARE FOR ENTIRE PROJECT.
LIMIT OF W
O
R
K
LIMIT OF WORK
LI
M
I
T
O
F
W
O
R
K
ROOT BARRIER
SYMBOL BOTANICAL / COMMON NAME CONT QTY
TREES
ALNUS RHOMBIFOLIA / WHITE ALDER 24"BOX 8
CUPRESSUS MACROCARPA / MONTEREY CYPRESS 24"BOX 5
PLATANUS RACEMOSA / CALIFORNIA SYCAMORE MULTI-TRUNK 24"BOX 2
QUERCUS AGRIFOLIA / COAST LIVE OAK 24"BOX 10
X CHITALPA TASHKENTENSIS / CHITALPA 24"BOX 13
SHRUBS
ARCTOSTAPHYLOS X 'PACIFIC MIST' / PACIFIC MIST MANZANITA 5 GAL 18
HETEROMELES ARBUTIFOLIA / TOYON 15 GAL 9
JUNCUS PATENS 'ELK BLUE' / SPREADING RUSH 1 GAL 26
LEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYE 1 GAL 100
•••••••••••••••••••••••••••••••• • • • • • • •• • • •• • •••••••••••••••••••••••••••••••••••••••••••••••••1 GAL 173
MYRICA CALIFORNICA / PACIFIC WAX MYRTLE 15 GAL 3
GROUND COVERS
BARK MULCH NA 52,058 SF
PEA GRAVEL NA 11,935 SF
TURF SOD / DROUGHT TOLERANT FESCUE BLEND NA 25,889 SF
PLANT SCHEDULE
FILE NAME: 0061-0118 PLNT.DWG
MCC
EAS
SLB
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
ROOT BARRIER
TYP.
ROOT BARRIER
Page 51 of 57
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
•
•
••
•
•
••
••
••
••
••
••
••
••
••
••••••••••••
••
••
••••
••••
••
••
••••••••••••••••••••••••••
•
•
••••
••
••••
•
•••
//////////////////
/
/
/
/
//
//////
/
/
/
//////
/
/
/
/
/
/
/////////
/////////
//////
/
/
/
/
/
/
O/HO/HO/HO/HO/HO/H
O/H O/H O/H O/H O/H O/H
SD
•
•
••
••
••••
••••
••••••••••
•
IR
R
IR
R
IR
R
IR
R
SD
ELEELEELE
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
NOTES:
1. QUANTITIES SHOWN ARE FOR ENTIRE PROJECT.
ROOT BARRIER
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
P
P
-
1
SYMBOL BOTANICAL / COMMON NAME CONT QTY
TREES
ALNUS RHOMBIFOLIA / WHITE ALDER 24"BOX 8
CUPRESSUS MACROCARPA / MONTEREY CYPRESS 24"BOX 5
PLATANUS RACEMOSA / CALIFORNIA SYCAMORE MULTI-TRUNK 24"BOX 2
QUERCUS AGRIFOLIA / COAST LIVE OAK 24"BOX 10
X CHITALPA TASHKENTENSIS / CHITALPA 24"BOX 13
SHRUBS
ARCTOSTAPHYLOS X 'PACIFIC MIST' / PACIFIC MIST MANZANITA 5 GAL 18
HETEROMELES ARBUTIFOLIA / TOYON 15 GAL 9
JUNCUS PATENS 'ELK BLUE' / SPREADING RUSH 1 GAL 26
LEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYE 1 GAL 100
•••••••••••••••••••••••••••••••• • • • • • • •• • • •• • •••••••••••••••••••••••••••••••••••••••••••••••••1 GAL 173
MYRICA CALIFORNICA / PACIFIC WAX MYRTLE 15 GAL 3
GROUND COVERS
BARK MULCH NA 52,058 SF
PEA GRAVEL NA 11,935 SF
TURF SOD / DROUGHT TOLERANT FESCUE BLEND NA 25,889 SF
PLANT SCHEDULE
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FILE NAME: 0061-0118 PLNT.DWG
MCC
EAS
SLB
ROOT BARRIER
TYP.
Page 52 of 57
PLANTING NOTES:
1. REFER TO PLANTING PLANS, PLAN NOTES, SPECIFICATIONS, PLANT LEGEND, AND PLANTING DETAILS FOR
ADDITIONAL PLANTING INFORMATION. REFER TO IRRIGATION PLANS, NOTES, SPECIFICATIONS, AND
DETAILS FOR RELATED LANDSCAPE WORK.
2. NOTIFY OWNER'S REPRESENTATIVE (REP.) 48 HOURS MINIMUM PRIOR TO COMMENCEMENT OF WORK TO
COORDINATE PROJECT INSPECTION SCHEDULE.
3. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE PROCEEDING WITH THE WORK.
IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE OF FIELD CONDITIONS THAT VARY FROM THOSE SHOWN
ON DRAWINGS AND SEEK CORRECTIONS AND DIRECTIONS BEFORE PROCEEDING WITH WORK. ASSUME
FULL RESPONSIBILITY FOR ALL NECESSARY CORRECTIONS DUE TO FAILURE TO REPORT KNOWN
DISCREPANCIES.
4.LOCATE AND MARK ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT. PROTECT FROM DAMAGE
ALL UTILITIES, AREAS AND STRUCTURES IN AND AROUND LANDSCAPE WORK AREAS. ASSUME FULL
RESPONSIBILITY AND EXPENSE FOR REPAIR AND REPLACEMENT OF DAMAGES CAUSED BY CONTRACTOR.
5. LOCATION OF NON-LANDSCAPE CONSTRUCTION ELEMENTS SUCH AS LIGHTS, SIGNS, VENTS, HYDRANTS,
TRANSFORMERS, AND OTHER STRUCTURES OR ELEMENTS ARE APPROXIMATE. CONTRACTOR SHALL
VERIFY FIELD CONDITIONS WHETHER SHOWN HEREON OR NOT. WHEN SHOWN ITEMS DO NOT
CORRESPOND TO FIELD CONDITIONS, REPORT DISCREPANCIES TO OWNER'S REP. FOR CLARIFICATIONS
AND INSTRUCTIONS PRIOR TO PROCEEDING WITH WORK.
6. PLANTING ACCESSORIES & MATERIAL:
A. TREE TIE: CINCH TIE, BY V.I.T. PRODUCTS, 800-729-1314.
B. FERTILIZER TABLETS: AGRIFORM (OR APPROVED EQUAL) 20-10-5, THREE 20-GRAM TABLETS FOR 15
GALLON OR LARGER SIZE TREES, TWO 10-GRAM TABLETS FOR 5 GALLON SIZE PLANTS, ONE 10-GRAM
TABLET FOR 1 GALLON SIZE.
C.ROOT BARRIER: 18" DEEP X 24" INJECTION MOLDED CO-POLYMER POLYPROPYLENE ROOT BARRIER
PANELS
D. TOPSOIL (BACKFILL MIX): 60-70% LOAM TOPSOIL THOROUGHLY MIXED WITH 30-40% FULLY COMPOSTED
ORGANIC MATERIAL.
E. MULCH: CONIFEROUS BARK MULCH AS SHOWN ON PLAN AND AT SHRUB ONLY LOCATIONS WHERE NO
COARSE GRAVEL OR RIVER COBBLE IS SHOWN. SUBMIT SAMPLE FOR APPROVAL.
7. PROVIDE AGRONOMIC SOIL TEST PER SPECIFICATIONS.
8. BACKFILL MIX: PREPARE IN ACCORDANCE TO SOIL TEST REPORT'S RECOMMENDATIONS, ADDING
AMENDMENTS, FERTILIZER, AND OTHER MATERIAL AS REQUIRED TO SITE SOIL.
9. ADD FERTILIZER AND AMENDMENTS TO THE SITE SOIL PER SOIL TEST REPORT RECOMMENDATIONS FOR
PLANTING WORK.
10. PRE-PLANTING PREPARATION:
A. PROCEED WITH PLANTING WORK ONLY AFTER IRRIGATION WORK IS COMPLETED, TESTED, AND
APPROVED BY OWNER'S REP. PROTECT IRRIGATION SYSTEM FROM DAMAGE.
B. REMOVE ALL ROCKS GREATER THAN 1" DIAMETER AND ALL DEBRIS AND DELETERIOUS MATERIAL FROM
PLANTING AREAS.
11. PLANTS: ALL PLANTS OF THE SAME SPECIES/CULTIVAR/VARIETY SHALL HAVE MATCHING FORM, FLOWER
COLOR, AND SIZE, IN HEALTHY AND THRIVING CONDITION, FREE FROM INJURIES, DISEASES, PESTS AND
ROOT-BOUND OR GIRDLING ROOTS. REPLACE REJECTED PLANTS WITH MATCHING SPECIES, SIZE AND
FORM.
12. PLANTING:
A.IRRIGATE PLANTING AREAS TO BRING TOP 6" OF SOIL TO FIELD CAPACITY. ALLOW SOIL TO DRAIN. DO
NOT WORK SOIL UNTIL IT RETURNS TO A MOIST FRIABLE CONDITION. TREE EXCAVATIONS MAY REQUIRE
ADDITIONAL IRRIGATION. FLOOD TREE PITS AS REQUIRED TO MOISTEN SUBGRADE.
B. PLACE PLANTS IN THEIR CONTAINERS AT THE LOCATIONS PER PLANS FOR APPROVAL BY OWNER'S REP.
MAKE MINOR ADJUSTMENTS AS REQUIRED BY FIELD CONDITIONS AND TO ALLOW OPTIMAL IRRIGATION
COVERAGE.
C. PLANT QUANTITIES GIVEN ON PLANT LEGEND ARE FOR GENERAL GUIDANCE ONLY. PROVIDE THE
SPECIFIED PLANT SPECIES IN THE QUANTITIES AT THE REQUIRED SPACING TO ACHIEVE THE DESIGN
EFFECT/INTENT SHOWN ON THE PLANS.
D. FOR TREES WITHIN 6 FEET OF PAVEMENT AND SLAB FOUNDATIONS, PRIOR TO TREE PLACEMENT,
INSTALL ROOT BARRIER PANELS ALL AROUND THE PLANT PIT PER THE MANUFACTURERS INSTALLATION
INSTRUCTIONS AND DETAIL 2, THIS SHEET.
E. PLANT TREES AND SHRUBS AS SHOWN ON DETAILS.
F.INSTALL 3" DEEP CONIFEROUS BARK MULCH TO COVER BARE SOIL AROUND TREES & SHRUBS. KEEP
MULCH 3" AWAY FROM SHRUB TRUNKS, 6-8" AWAY FROM TREE TRUNKS. DO NOT INSTALL CONIFEROUS
BARK MULCH WHERE MINERAL MULCHES (PEA GRAVEL) OCCUR.
G. INSTALL 2" DEEP PEA GRAVEL WHERE SHOWN ON PLANS.
12. 90 DAY MAINTENANCE PERIOD: MAINTAIN PLANTINGS IN THRIVING CONDITION USING ACCEPTED INDUSTRY
PRACTICES FOR WATERING, FERTILIZING, AND PRUNING. DO NOT MOW BIOFILTRATION SOD. MAINTAIN
TREE STAKES IN PROPER POSITIONS. REMOVE TREE STAKES AT END OF MAINTENANCE PERIOD. REPLACE
PLANTS THAT DIE OR FAIL TO ESTABLISH IN THRIVING CONDITION WITH SPECIES, SIZE AND FORM
MATCHING OTHERS ON SITE. REPAIR OR REPLACE BROKEN IRRIGATION COMPONENTS.
13. WARRANTY: WARRANT PLANT MATERIAL AND IRRIGATION SYSTEM FOR ONE YEAR FROM END OF
MAINTENANCE PERIOD. REPLACE DEAD OR DYING PLANTS AND BROKEN IRRIGATION COMPONENTS
WITHIN THIS PERIOD.
ROOT BARRIER TREE PLANTING ONLY
SCALE = NTS
1
2
ROOT BALL
3
4
5
4"
MIN
4"
MIN
PLANTING AT
TURF AREAS
PLANTING AT
SHRUB AREAS
6
7
8
9
10
NOTES:
A. SET ROOT BALL CROWN 1
12" HIGHER
THAN FINISHED GRADE. SLOPE
BACKFILL AWAY FROM ROOT BALL
FOR POSITIVE DRAINAGE
B. ROOT BARRIER TO BE PLACED MIN. 4"
FROM ROOT BALL
C. 4" MIN. GRAVEL BACKFILL REQUIRED
MIN. 6' - 8"24" DEEP ROOT BARRIER SYSTEM. FACE
ROOT GUIDING RIBS TOWARD ROOT BALL
1
3/4" CRUSHED ROCK OUTSIDE OF BARRIER2
EXCAVATE 12" OF SOIL BELOW ROOT
BARRIER SYSTEM. REPLACE WITH FIRMLY
COMPACTED AMENDED BACKFILL.
3
PLANT TABLETS. SEE PLANTING NOTES.4
AMENDED BACKFILL, COMPACTED5
RECESS 1" AT TURF TO ALLOW FOR MULCH6
3" THICK MULCH LAYER7
2" HIGH WATER WELL AT SHRUBS8
KEEP MULCH 6 - 8" FROM BASE OF TREE9
FINISHED GRADE10
LEGEND:
3 329343.19-37
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
MCC
EAS
SLB
Page 53 of 57
/
/
/
//
/
/
/
/
/
/
/////////////////////
///
///
//////////////////
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
///
/
/
/
////////////////////////
///
///
///
//////////////////
////
//
///
••
••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•
•
•
•
••
••
••
••
••
••
••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••
••
••
••
••
••
••
••
••
••
••
••
/
////
/
1
20.01"
2
18.61"
4
47.6112"
5
11112"
6
47.6112"
3
19.81"
7
38.12"
8
40.52"
9
38.12"
10
39.82"
11
19.31"
12
19.41"
WL
WL
WL
SS
WL
WL
WL
WL
WL
SS
SS
15
30.42"
16
54112"
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
HUNTER RZWS-SLEEVE-18-CV 25
18" LONG RZWS WITH FILTER FABRIC SLEEVE, .25 GPM OR
.50 GPM BUBBLER OPTIONS, CHECK VALVE, 1/2" SWING
JOINT FOR CONNECTION TO 1/2" PIPE
76 30
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS
HUNTER I-40-06-SS-HS 08
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
6407.641'
HUNTER I-40-06-SS-HS 10
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
4 50 10.3 45'
HUNTER I-40-06-SS-HS 13
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
3 50 11.1 46'
HUNTER I-40-06-SS-HS 15
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
16 50 13.5 51'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD XCZ-150-LCS
HIGH FLOW CONTROL ZONE KIT, FOR LARGE COMMERCIAL
DRIP ZONES. 1-1/2IN. PEB GLOBE VALVE WITH SINGLE
1-1/2IN. PRESSURE REGULATING 40PSI QUICK-CHECK
BASKET FILTER. FLOW RANGE: 15-62 GPM.
5
RAIN BIRD XCZLF-100-PRF
LOW FLOW, 0.2-10 GPM, WITH 1IN. LOW FLOW VALVE
VALVE AND 1IN. PRESSURE REGULATING RBY FILTER AND
40PSI PRESSURE REGULATOR.
1
RAIN BIRD MDCFCAP
DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING
COUPLER.
6
RAIN BIRD ARV050
1/2IN. AIR RELIEF VALVE, MADE OF QUALITY RUST-PROOF
MATERIALS, WITH A 6IN. DRIP VALVE BOX (SEB 7XB
EMITTER BOX). USE WITH INSTALLATION BELOW SOIL. THE
VALVE WILL ALLOW AIR TO ESCAPE THE PIPELINE, THUS
PREVENTING WATER HAMMER OR BLOCKAGE.
6
AREA TO RECEIVE DRIP EMITTERS
RAIN BIRD XBCV-PC
SINGLE OUTLET, PRESSURE COMPENSATING DRIP
EMITTERS. FLOW RATES OF 0.5 GPH=BLUE, 1.0
GPH=BLACK, AND 2.0 GPH=RED. COMES WITH A
SELF-PIERCING BARB INLET X BARB OUTLET. WITH CHECK
VALVE.
2,637 S.F.
AREA TO RECEIVE DRIPLINE
NETAFIM TLCV-09-12
TECHLINE PRESSURE COMPENSATING LANDSCAPE
DRIPLINE WITH CHECK VALVE. 0.9 GPH EMITTERS AT 12"
O.C. DRIPLINE LATERALS SPACED AT 12" APART, WITH
EMITTERS OFFSET FOR TRIANGULAR PATTERN. 17MM.
6,469 S.F.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
HUNTER ICV-G-FS (2)
1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT
THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL
USE. WITH FILTER SENTRY.
10
RAIN BIRD 44-LRC (2)
1IN. BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING,
LOCKING THERMOPLASTIC RUBBER COVER, AND 2-PIECE
BODY.
13
MAINLINE ISOLATION GATE VALVE
NIBCO T-134 THREADED (2-1/2" - 6" SIZE), NIBCO T-113 (2" &
SMALLER SIZE).
7
BUCKNER-SUPERIOR 3100-PRS-BSPT 1-1/2"
NORMALLY OPEN BRASS MASTER VALVE THAT PROVIDES
DIRTY WATER PROTECTION. AVAILABLE IN 3/4", 1", 1-1/4",
1-1/2", 2", 2-1/2" AND 3". WITH BRITISH THREAD. PRESSURE
REGULATION FEATURE, OR APPROVED EQUAL. PROVIDE
DC LATCHING SOLENOID AND DECODER FOR 2-WIRE
OPERATION.
1
CALSENSE CS3-16-WM GR-BUNDLE-2
CALSENSE CS3000 16-STATION CONTROLLER WITH THE
WEATHER OPTION, MODEL CS3-W-KIT, TO KEEP A RECORD
OF ACCUMULATED RAINFALL. CONTROLLER TO BE WITHIN
A RUGGED, LOCKABLE, VANDAL-PROOF STAINLESS STEEL
WALL-MOUNT ENCLOSURE MOUNTED ON WALL INSIDE
RESTROOM STORAGE AREA.
1
CALSENSE RB-1
CALSENSE TIPPING RAIN BUCKET WITH 25FT TWO WIRE
CABLE. EXTENDABLE UP TO 1000FT WITH P7171D CABLE
(NOT INCLUDED).
1
CALSENSE FM-1.25B
CALSENSE IMPELLER FLOW SENSOR. 1-1/4IN. BRASS
TEE-MOUNTED. 3 GPM-81 GPM.
1
POINT OF CONNECTION
TEE INTO EXISTING IRRIGATION MAIN LINE
1
IRRIGATION LATERAL LINE: PVC SCHEDULE 40 4,608 L.F.
IRRIGATION MAINLINE: PVC SCHEDULE 40 1,484 L.F.
PIPE SLEEVE: PVC CLASS 315 SDR 13.5
TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. PIPE SLEEVE
SIZE SHALL ALLOW FOR IRRIGATION PIPING AND THEIR
RELATED COUPLINGS TO EASILY SLIDE THROUGH
SLEEVING MATERIAL. EXTEND SLEEVES 12 INCHES
BEYOND EDGES OF PAVING OR CONSTRUCTION.
133.1 L.F.
C
WS
FS
IRRIGATION SCHEDULE
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
DALIDIO
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
I
P
-
2
FILE NAME: 0061-0118 IRRG.DWG
MCC
EAS
SLB
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
Page 54 of 57
/
/
/
/////////
/////////
//////
/
/
/
/
/
/
/
/
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
••
•
•
••
•
•
••
••
••
••
••
••
••
••
••
••••••••••••
••
••
••
••
••••
••
••
••••••••••••••••••••••••••
•
•
••
••
•
•
•
•
•
•
••
••
••••
FS
C
14
81"
13
2.171"
WS
ELEELEELE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
HUNTER RZWS-SLEEVE-18-CV 25
18" LONG RZWS WITH FILTER FABRIC SLEEVE, .25 GPM OR
.50 GPM BUBBLER OPTIONS, CHECK VALVE, 1/2" SWING
JOINT FOR CONNECTION TO 1/2" PIPE
76 30
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS
HUNTER I-40-06-SS-HS 08
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
6407.641'
HUNTER I-40-06-SS-HS 10
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
4 50 10.3 45'
HUNTER I-40-06-SS-HS 13
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
3 50 11.1 46'
HUNTER I-40-06-SS-HS 15
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE TO FULL CIRCLE.
DRAIN CHECK VALVE, STAINLESS STEEL RISER, 1IN.
FEMALE NPT INLET THREADS, HIGH SPEED NOZZLE.
16 50 13.5 51'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD XCZ-150-LCS
HIGH FLOW CONTROL ZONE KIT, FOR LARGE COMMERCIAL
DRIP ZONES. 1-1/2IN. PEB GLOBE VALVE WITH SINGLE
1-1/2IN. PRESSURE REGULATING 40PSI QUICK-CHECK
BASKET FILTER. FLOW RANGE: 15-62 GPM.
5
RAIN BIRD XCZLF-100-PRF
LOW FLOW, 0.2-10 GPM, WITH 1IN. LOW FLOW VALVE
VALVE AND 1IN. PRESSURE REGULATING RBY FILTER AND
40PSI PRESSURE REGULATOR.
1
RAIN BIRD MDCFCAP
DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING
COUPLER.
6
RAIN BIRD ARV050
1/2IN. AIR RELIEF VALVE, MADE OF QUALITY RUST-PROOF
MATERIALS, WITH A 6IN. DRIP VALVE BOX (SEB 7XB
EMITTER BOX). USE WITH INSTALLATION BELOW SOIL. THE
VALVE WILL ALLOW AIR TO ESCAPE THE PIPELINE, THUS
PREVENTING WATER HAMMER OR BLOCKAGE.
6
AREA TO RECEIVE DRIP EMITTERS
RAIN BIRD XBCV-PC
SINGLE OUTLET, PRESSURE COMPENSATING DRIP
EMITTERS. FLOW RATES OF 0.5 GPH=BLUE, 1.0
GPH=BLACK, AND 2.0 GPH=RED. COMES WITH A
SELF-PIERCING BARB INLET X BARB OUTLET. WITH CHECK
VALVE.
2,637 S.F.
AREA TO RECEIVE DRIPLINE
NETAFIM TLCV-09-12
TECHLINE PRESSURE COMPENSATING LANDSCAPE
DRIPLINE WITH CHECK VALVE. 0.9 GPH EMITTERS AT 12"
O.C. DRIPLINE LATERALS SPACED AT 12" APART, WITH
EMITTERS OFFSET FOR TRIANGULAR PATTERN. 17MM.
6,469 S.F.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
HUNTER ICV-G-FS (2)
1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT
THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL
USE. WITH FILTER SENTRY.
10
RAIN BIRD 44-LRC (2)
1IN. BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING,
LOCKING THERMOPLASTIC RUBBER COVER, AND 2-PIECE
BODY.
13
MAINLINE ISOLATION GATE VALVE
NIBCO T-134 THREADED (2-1/2" - 6" SIZE), NIBCO T-113 (2" &
SMALLER SIZE).
7
BUCKNER-SUPERIOR 3100-PRS-BSPT 1-1/2"
NORMALLY OPEN BRASS MASTER VALVE THAT PROVIDES
DIRTY WATER PROTECTION. AVAILABLE IN 3/4", 1", 1-1/4",
1-1/2", 2", 2-1/2" AND 3". WITH BRITISH THREAD. PRESSURE
REGULATION FEATURE, OR APPROVED EQUAL. PROVIDE
DC LATCHING SOLENOID AND DECODER FOR 2-WIRE
OPERATION.
1
CALSENSE CS3-16-WM GR-BUNDLE-2
CALSENSE CS3000 16-STATION CONTROLLER WITH THE
WEATHER OPTION, MODEL CS3-W-KIT, TO KEEP A RECORD
OF ACCUMULATED RAINFALL. CONTROLLER TO BE WITHIN
A RUGGED, LOCKABLE, VANDAL-PROOF STAINLESS STEEL
WALL-MOUNT ENCLOSURE MOUNTED ON WALL INSIDE
RESTROOM STORAGE AREA.
1
CALSENSE RB-1
CALSENSE TIPPING RAIN BUCKET WITH 25FT TWO WIRE
CABLE. EXTENDABLE UP TO 1000FT WITH P7171D CABLE
(NOT INCLUDED).
1
CALSENSE FM-1.25B
CALSENSE IMPELLER FLOW SENSOR. 1-1/4IN. BRASS
TEE-MOUNTED. 3 GPM-81 GPM.
1
POINT OF CONNECTION
TEE INTO EXISTING IRRIGATION MAIN LINE
1
IRRIGATION LATERAL LINE: PVC SCHEDULE 40 4,608 L.F.
IRRIGATION MAINLINE: PVC SCHEDULE 40 1,484 L.F.
PIPE SLEEVE: PVC CLASS 315 SDR 13.5
TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. PIPE SLEEVE
SIZE SHALL ALLOW FOR IRRIGATION PIPING AND THEIR
RELATED COUPLINGS TO EASILY SLIDE THROUGH
SLEEVING MATERIAL. EXTEND SLEEVES 12 INCHES
BEYOND EDGES OF PAVING OR CONSTRUCTION.
133.1 L.F.
C
WS
FS
IRRIGATION SCHEDULE
002040
(IN FEET)
10
GRAPHIC SCALE
1 IN = 20 FT
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
I
P
-
1
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FILE NAME: 0061-0118 IRRG.DWG
MCC
EAS
SLB
Page 55 of 57
IRRIGATION NOTES:
1. THE SYSTEM DESIGN SHOWN IS BASED UPON A MINIMUM PRESSURE OF 80 PSI AT A MAXIMUM
DISCHARGE OF 80 GPM. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION WORK
AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE.
2. ALL WORK SHALL CONFORM TO LOCAL AND STATE CODES AND ORDINANCES AND THE PLANS,
SPECIFICATIONS, DETAILS AND NOTES FOR THIS PROJECT. READ THOROUGHLY AND BECOME
FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK
PRIOR TO CONSTRUCTION.
3. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, INCLUDING, BUT NOT LIMITED TO,
UNDERGROUND UTILITIES AND STRUCTURES. COORDINATE ALL WORK WITH CIVIL, MECHANICAL,
AND ELECTRICAL WORK AND TRADES TO MINIMIZE CONFLICTS. THE WORK INCLUDES THE
RESPONSIBILITY FOR THE INSTALLATION OF IRRIGATION SLEEVING. CONTRACTOR SHALL
COORDINATE SLEEVE INSTALLATION AND SEQUENCE HIS WORK WITH ALL WORK AND
DISCIPLINES AS REQUIRED.
4. LAYOUT SHOWN IS DIAGRAMMATIC. IRRIGATION PIPING AND COMPONENTS MAY BE SHOWN
OUTSIDE PLANTING AREAS FOR CLARITY. INSTALL IRRIGATION PIPING AND WIRING IN
LANDSCAPED AREAS WHENEVER POSSIBLE. INSTALL IRRIGATION VALVES IN GROUND COVER OR
SHRUB AREAS WHENEVER POSSIBLE. LOCATE IRRIGATION CONTROL AND QUICK COUPLING
VALVES ADJACENT TO HARDSCAPE OR TURF AREAS FOR EASY ACCESS. AVOID CONFLICTS
BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIAL, AND ARCHITECTURAL FEATURES.
5. DO NOT PROCEED WITH THE INSTALLATION OF THE SYSTEM WHEN IT IS EVIDENT THAT FIELD
CONDITIONS OR DIFFERENCES EXIST THAT COULD NOT HAVE BEEN CONSIDERED IN
ENGINEERING OR IF DISCREPANCIES IN CONSTRUCTION DRAWINGS, DETAILS, NOTES AND
SPECIFICATIONS ARE DISCOVERED. BRING ALL SUCH DIFFERING FIELD CONDITIONS AND
DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE.
6. THE BACKFLOW PREVENTION DEVICE IS EXISTING AND LOCATED AT PARK ENTRANCE ALONG
MADONNA RD.
7. SEE LEGEND FOR PIPING MATERIAL. SEE DRAWINGS AND LEGEND FOR PIPE SIZES. SIZE
CALLOUTS ON DRAWINGS INDICATE NOMINAL PIPE SIZE. UNLABELED SECTIONS ARE THE
NOMINAL SIZE OF THE PRECEDING CALLOUT. SUBSEQUENT CALLOUTS INDICATE CHANGE IN PIPE
SIZE.
8. UNLESS OTHERWISE NOTED, TRENCHING DEPTHS FOR IRRIGATION SHALL BE 18" FOR
MAINLINES AND 12" FOR LATERALS. DEPTH SHALL BE MEASURED FROM THE TOP OF PIPE TO
FINISHED SOIL LEVEL.
9. INSTALL CONCRETE THRUST BLOCKS ON ALL MAINLINES THREE (3) INCHES AND LARGER IN
DIAMETER IN ACCORDANCE WITH LOCAL CODES AND STANDARDS OR ASAE STANDARD S376.1.
10. ALL MAINLINES, LATERALS, AND CONTROL WIRES UNDER PAVEMENT OR CONCRETE SHALL BE
INSTALLED IN SCHEDULE 40 PVC SLEEVES. SLEEVES SHALL EXTEND 12" BEYOND EDGE OF
PAVEMENT AND SHALL HAVE ENDS CLEARLY MARKED ABOVE GRADE DURING CONSTRUCTION.
11. PRIOR TO BACKFILLING, FLUSH AND TEST MAINS AND LATERALS. FLUSH MAINS BEFORE
INSTALLING VALVES. FLUSH LATERALS BEFORE INSTALLING SPRINKLERS. SUBJECT MAINS TO
HYDROSTATIC PRESSURE OF 1.5 TIMES THE ANTICIPATED OPERATING PRESSURE (MIN. 100 PSI)
FOR TWO HOURS. SUBJECT LATERALS TO HYDROSTATIC PRESSURE EQUAL TO ANTICIPATED
OPERATING PRESSURE. ALL FLUSHING SHALL BE DONE IN THE PRESENCE OF THE ARCHITECT.
BACKFILL WITH CLEAN MATERIAL FROM EXCAVATION. REMOVE ROCKS AND DEBRIS LARGER
THAN 1" DIAMETER.
12. INSTALL QUICK COUPLING VALVE ASSEMBLIES AS SHOWN OR APPROXIMATELY 50 FEET ON
CENTER FOR IRRIGATION AND HARDSCAPE WASHDOWN WATER.
13. THE FINAL LOCATION OF THE IRRIGATION CONTROLLER SHALL BE APPROVED BY OWNER'S
REPRESENTATIVE PRIOR TO INSTALLATION. 120V ELECTRICAL SUPPLY SHALL BE BY OTHERS.
THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING THE FINAL CONNECTION TO
THE CONTROLLER IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND
LOCAL ELECTRICAL CODES.
14. INSTALL ONE (1) AWG #14 CONTROL WIRE (WIRE COLOR TO VARY FOR EACH VALVE) FROM
THE CONTROLLER TO EACH REMOTE CONTROL VALVE. INSTALL ONE (1) AWG #14 WIRE (GREEN)
FROM THE CONTROLLER TO THE MOST REMOTE REMOTE CONTROL VALVE ALONG EACH BRANCH
OF WIRING RUNS FOR USE AS A SPARE CONTROL WIRE. INSTALL ONE (1) AWG #12 WIRE (WHITE)
FOR COMMON GROUND. COIL THREE (3) FEET OF WIRE IN EACH VALVE OR SPLICE BOX. USE 3M
DBY SPLICE KITS FOR ALL WIRE CONNECTIONS AND SPLICES.
15. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE AND UNIFORM COVERAGE OF ALL
PLANTED AREAS. ADJUST REMOTE CONTROL VALVE PRESSURE REGULATOR AND FLOW
CONTROL TO BALANCE EACH LATERAL SYSTEM AND TO ENSURE PROPER VALVE CLOSURE TIME.
SELECT AND ADJUST NOZZLES FOR SPRAY AND BUBBLER SPRINKLERS WITH RADII AND ANGLES
TO ENSURE UNIFORM COVERAGE WITH MINIMUM OVERSPRAY. SELECT NOZZLES FOR ROTARY
SPRINKLERS AND ADJUST DIFFUSER AND RADIUS TO ENSURE UNIFORM COVERAGE WITH
MINIMUM OVERSPRAY.
16. CONTRACTOR SHALL ADJUST SPRINKLER HEAD LOCATION(S) AND ADD HEADS AS REQUIRED
TO ACCOMMODATE VERTICAL OBSTRUCTIONS, INCLUDING, BUT NOT LIMITED TO LIGHT POLES,
FIRE HYDRANTS, AND SIGNAGE.
17. INSTALL PLASTIC CHECK VALVES AT THE BASE OF ALL SPRINKLER HEADS OR INSTALL
SPRINKLER HEADS WITH INTEGRAL CHECK VALVES AS REQUIRED TO PREVENT LOW-HEAD
DRAINAGE.
1" = 1'-0"
WALL MOUNT CONTROLLER
LEGEND:
SET THE CONTROLLER 60" ABOVE FINISHED
GRADE IN A WATERPROOF ENCLOSURE
UNLESS OTHERWISE NOTED
1
CONTROLLER AS SPECIFIED.
SECURELY BOLT CONTROLLER TO WALL.
INSTALL BACKUP BATTERIES AS REQUIRED.
GROUND AS PER MANUFACTURER'S
SPECIFICATIONS.
2
2" DIAMETER RIGID STEEL CONDUIT FOR RCV
WIRES
3
1/2" DIA. RIGID STEEL CONDUIT FOR 110 VAC
ELECTRICAL SOURCE. INSTALL AS PER LOCAL
ELECTRICAL CODES
4
12" X 12" X 4" STEEL JUNCTION BOX. GROUP
WIRE BUNDLES AND SPLICE TO 18 GA. WIRES
WITH TERMINAL STRIP AS PER
SPECIFICATIONS
5
2" DIAMETER RIGID STEEL CONDUIT FOR RCV
WIRES
6
FINISHED GRADE7
LONG SWEEP ELL8
USE PVC SCH. 40 BELOW GRADE9
1
2
3
4
6
7
5
8
9
2 328409.13-02
1/43/4
1/81/21
SECTION/ELEVATION
WIRELESS RAIN SENSOR - ROOF LINE MOUNT
NOTE:
MOUNT SENSOR VERTICALLY. AVOID PLACEMENT UNDER EVE OR TREE CANOPY. LOCATE WITHIN 300
FEET OF SENSOR RECEIVER AND CONTROLLER.
NOTES:
A. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
B. DO NOT SCALE DRAWINGS.
C. CONTRACTOR NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT: www.CADdetails.com/info
REFERENCE NUMBER O65-256b.
LEGEND:
TORO WIRELESS RAIN
SENSOR, MODEL NO.
TWRFS
1
ADJUSTABLE MOUNTING
BRACKET
2
WOOD SCREW3
BUILDING WALL AT ROOF
LINE
4
ANTENNA5
1
2 3
4
5
3
NOTE:
A. REPLACE EXISTING CONTROLLER AND
USE EXISTING CONDUIT SWEEP
Hunter pop up indicator13
13 TYP.
FILE NAME: 0061-0118 IRRG-DETL.DWG
MCC
EAS
SLB
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
Page 56 of 57
Emboss Valve # on lid
Emboss "MV" AND "FS" on lid
Emboss "QC" on lid
Emboss "IV" on lid
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SHEET DES.DESCRIPTION CITYENGINEER
DESIGNDATE
APPROVALREVISIONS
#
2000526-01
FILE NAME: 0061-0118 IRRG-DETL.DWG
MCC
EAS
SLB
Page 57 of 57