Loading...
HomeMy WebLinkAboutPRR24262 Ruda Dummit Emails1 From:Hanh, Hannah Sent:Tuesday, April 23, 2024 7:39 PM To:Jordan Knauer Subject:3160 Johnson - 04/22 MS Hearing Public Correspondence Attachments:240422 City SLO.pdf Hi Jordan, I believe Shae forwarded the correspondence that was submitted on behalf of Jim Dummit after the meeting yesterday. You likely have copies already, but I wanted to follow up with that information to confirm on my end. See attached letter and supporting nine (9) attachments from Ogden & Fricks in link below. https://www.dropbox.com/scl/fo/ol6vbt6bl9w1exoa5ejne/AFz47yqMILhZBOoX0esU6Zw?rlkey=y9nmnbbp78j77czie knxjvvb8&st=qgmpp2la&dl=0 Sincerely, Hannah Hanh Associate Planner Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 E hhanh@slocity.org T 805.781.7432 slocity.org Stay connected with the City by signing up for e-notifications 1 From:james dummit < Sent:Monday, March 4, 2024 1:53 PM To:Monroe, Nicole Subject:1382 Aralia Ct. BLDG-2287-2023 Attachments:10262023162317.pdf; AraliaT24OFFICIAL.pdf This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. ________________________________ Nicole attached Digital files for above referenced ADU please let me know if anything else required. Thank you for your help jim BUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC – www.energysoft.com. , 1382 Aralia Court Aralia Court Addition San Luis Obispo, CA 93401 2238 Bayview Heights Drive, Suite E Carstairs Energy Inc. Timothy Carstairs, CEA, HERS, GPR Los Osos, CA 93402 805-904-9048 23-080121 8/18/2023 TABLE OF CONTENTS Form MF1R Mandatory Measures Summary Room Load Summary Cover Page Table of Contents Form CF1R-PRF-01-E Certificate of Compliance Form RMS-1 Residential Measures Summary 17 22 1 2 3 15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 GENERAL INFORMATION 01 Project Name Aralia Court Addition 02 Run Title Title 24 Analysis 03 Project Location 1382 Aralia Court 04 City San Luis Obispo 05 Standards Version 2022 06 Zip code 93401 07 Software Version EnergyPro 9.1 08 Climate Zone 5 09 Front Orientation (deg/ Cardinal)225 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed Addition 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)395 15 Number of Stories 2 16 Existing Cond. Floor Area (ft 2)2656 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft 2)3051 19 Glazing Percentage (%)31.47% 20 ADU Bedroom Count 1 ADDITION ALONE - Project Analysis Parameters 01 02 03 04 05 06 Existing Area (excl. new addition) (ft2) Addition Area (excl. existing) (ft2)Total Area (ft2)Existing Bedrooms Addition Bedrooms Total Bedrooms 2656 395 3051 3 1 4 ADDITION ALONE - ACCESSORY DWELLING UNIT (ADU) PROJECT ANALYSIS PARAMETERS 01 02 03 04 05 06 07 08 Zone Name Existing Area (excl. new addition) (ft 2) ADU Area (excl. existing) (ft 2)Total Area (ft 2)Existing Bedrooms Addition Bedrooms Total Bedrooms Attached vs. Detached New ADU 2656 395 3051 3 1 4 Attached 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0 22.59 0 27.74 0 -5.15 Space Cooling 0 1.63 0 1.2 0 0.43 IAQ Ventilation 0 5.21 0 5.21 0 0 Water Heating 0 157.6 0 141.99 0 15.61 Self Utilization/Flexibility Credit Efficiency Compliance Total 0 187.03 0 176.14 0 10.89 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 6.91 0 6.91 Appl. & Cooking 0 113.61 0 113.42 Plug Loads 0 97.64 0 97.64 Outdoor Lighting 0 13.7 0 13.7 TOTAL COMPLIANCE 0 418.89 0 407.81 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 ENERGY USE INTENSITY Standard Design (kBtu/ft 2 - yr )Proposed Design (kBtu/ft 2 - yr )Compliance Margin (kBtu/ft 2 - yr ) Margin Percentage Gross EUI 1 82.51 78.57 3.94 4.78 Net EUI 2 82.51 78.57 3.94 4.78 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •New ductwork added is less than 25 ft. in length •Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Indoor air quality ventilation •Kitchen range hood •Verified Refrigerant Charge •Airflow in habitable rooms (SC3.1.4.1.7) •Verified heat pump rated heating capacity •Wall-mounted thermostat in zones greater than 150 ft2 (SC3.4.5) •Ductless indoor units located entirely in conditioned space (SC3.1.4.1.8) •Duct Sealing required if a duct system component, plenum, or air handling unit is altered ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Status New Main Addition Conditioned HVAC System (Main)1 74 8 DHW Sys 1 New New ADU Conditioned HVAC System (ADU)2 321 9 DHW Sys 1 New 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg)Wall Exceptions Status Rear Wall New Main Addition R-15 Wall 45 Back 99 28.7 90 Extension New Right Wall New Main Addition R-15 Wall 135 Right 63 14 90 Extension New Front Wall New ADU R-15 Wall 225 Front 40 0 90 Extension New Left Wall New ADU R-15 Wall 315 Left 168 32.1 90 Extension New Rear Wall 2 New ADU R-15 Wall 45 Back 184 0 90 Extension New Right Wall 2 New ADU R-15 Wall 135 Right 168 18 90 Extension New N Wall New ADU R-15 Wall 0 n/a 40 10.5 90 Extension New E Wall New ADU R-15 Wall 90 n/a 40 21 90 Extension New Interior Surface New Main Addition>>New ADU R-15 Wall1 n/a n/a 100 0 n/a New Interior Surface 2 New Main Addition>>New ADU R-15 Wall1 n/a n/a 100 0 n/a New Roof New Main Addition R-30 Roof Attic n/a n/a 74 n/a n/a New Roof 2 New ADU R-30 Roof Attic n/a n/a 321 n/a n/a New ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic New Main Addition Attic RoofNew Main Addition Ventilated 5 0.1 0.85 No No Attic New ADU Attic RoofNew ADU Ventilated 5 0.1 0.85 No No 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading W7 Window Rear Wall Back 45 1 10.7 0.3 NFRC 0.35 NFRC Bug Screen D5 Window Rear Wall Back 45 1 18 0.3 NFRC 0.35 NFRC Bug Screen W5 Window Right Wall Right 135 1 10 0.3 NFRC 0.35 NFRC Bug Screen W6 Window Right Wall Right 135 1 4 0.3 NFRC 0.35 NFRC Bug Screen D1 Window Left Wall Left 315 1 23.3 0.3 NFRC 0.35 NFRC Bug Screen W4 Window Left Wall Left 315 1 8.8 0.3 NFRC 0.35 NFRC Bug Screen D2 Window Right Wall 2 Right 135 1 18 0.3 NFRC 0.35 NFRC Bug Screen W3 Window N Wall 0 1 10.5 0.3 NFRC 0.35 NFRC Bug Screen W1 Window E Wall 90 1 10.5 0.3 NFRC 0.35 NFRC Bug Screen W2 Window E Wall 90 1 10.5 0.3 NFRC 0.35 NFRC Bug Screen SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab New Main Addition 74 18 none 0 80%No Slab 2 New ADU 321 80 none 0 80%No 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco R-15 Wall1 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Other Side Finish: Gypsum Board Attic RoofNew Main Addition Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofNew ADU Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 R-30 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Not Required Not Required N/A n/a n/a 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location DHW Heater 1 Gas Consumer Instantaneo us 1 0 UEF 0.93 Btu/Hr 200000 0 n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System (Main)1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 n/a 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System (ADU)2 Heat pump heating cooling Heat Pump System 2 1 Heat Pump System 2 1 n/a n/a Setback HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Electric 1 HSPF-3.41 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER/SEER 11.7 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationEfficiency Type HSPF / HSPF2 / COP Cap 47 Cap 17 Efficiency Type SEER / SEER2 EER / EER / CEER Heat Pump System 2 VCHP-ductless 1 HSPF 8.8 12000 8000 EERSEER 15 12.2 Not Zonal Single Speed Heat Pump System 2-hers-htpump 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 2-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Name Certified Low-Static VCHP System Airflow to Habitable Rooms Ductless Units in Conditioned Space Wall Mount Thermostat Air Filter Sizing &amp; Pressure Drop Rating Low Leakage Ducts in Conditioned Space Minimum Airflow per RA3.3 and SC3.3.3.4.1 Certified non-continuous Fan Indoor Fan not Running Continuously Heat Pump System 2 Not required Required Required Required Not required Not required Not required Not required Not required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Existing (not specified) Air Distribution System 1-hers-dist HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Not Required 0 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM) Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE Includes Fault Indicator Display? HERS Verification Status SFam ADU IAQVentRpt 25 0.35 Exhaust No n/a No Yes 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Timothy Carstairs Carstairs Energy Inc. 2238 Bayview Heights Drive, Suite E Los Osos, CA 93402 2023-08-18 14:07:15 r160610042 805-904-9048 Jim Dummit Jim Dummit 3100 Johnson Ave San Luis Obispo, CA 93401 2023-08-18 14:17:23 na Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type o Single Family o Addition Alone Date o Multi Family o Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Aralia Court Addition 1382 Aralia Court San Luis Obispo Wood Framed 8/18/2023 ✔✔ CA Climate Zone 05 395 1 Wood Framed Attic Wall Wall Roof Slab Demising Wall Wood Framed Wood Framed Unheated Slab-on-Grade Wood Framed 70 49 395 395 200 40 - no insulation - R 15 R 15 R 30 R 15 R 15 New New New New New New Perim = 98' 395 Rear (NE) Right (SE) Left (NW) Left (N) Rear (E) 28.7 32.0 32.1 10.5 21.0 0.300 0.300 0.300 0.300 0.300 0.35 0.35 0.35 0.35 0.35 none none none none none none none none none none N/A N/A N/A N/A N/A New New New New New 14.0 SEER1 1 No Heating Provided Electric Heat Pump Split Air Conditioner Split Heat Pump n/a 8.80 HSPF Existing New15.0 SEER Setback Setback AtticHVAC System (Main) HVAC System (ADU) Ducted Ductless Ducted Ductless / with Fan Altered Newn/a 6.0 n/a Standard1Small Instantaneous Gas 0.930 New ID: 23-080121 Page 15 of 23EnergyPro 9.2 by EnergySoft User Number: 6249 Wood FramedWall Wall Wood Framed 136 184 R 15 R 15 New New 124 31.5 %0.30 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type o Single Family o Addition Alone Date o Multi Family o Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Aralia Court Addition 1382 Aralia Court San Luis Obispo 8/18/2023 ✔✔ CA Climate Zone 05 395 1 Wood Framed Wall Wall Wall Wood Framed Wood Framed 150 30 19 R 15 R 15 R 15 New New New 395 ID: 23-080121 Page 16 of 23EnergyPro 9.2 by EnergySoft User Number: 6249 124 31.5 %0.30 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Building Envelope: § 110.6(a)1: Air Leakage.Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. * § 110.6(a)5: Labeling.Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC)values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. * § 110.7: Air Leakage.All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, gasketed, or weather stripped. § 110.8(a):Insulation Certification by Manufacturers.Insulation must be certified by the Department of Consumer Affairs,Bureau of Household Goods and Services (BHGS). § 110.8(g): Insulation Requirements for Heated Slab Floors.Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R. § 110.8(j):RadiantBarrier. When required, radiantbarriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. § 150.0(a): Roof Deck, Ceiling and Rafter Roof Insulation.Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. * § 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value. § 150.0(c): Wall Insulation.Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B. * § 150.0(d):Raised-floorInsulation.Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. * § 150.0(f): Slab Edge Insulation.Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(g)1: Vapor Retarder.In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to §150.0(d). § 150.0(g)2: Vapor Retarder.In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. § 150.0(q): Fenestration Products.Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. * Fireplaces, Decorative Gas Appliances, and Gas Log: § 110.5(e)PilotLight.Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)1: ClosableDoors.Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2: Combustion Intake.Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device. * § 150.0(e)3:FlueDamper.Masonry or factory-built fireplaces must have a flue damper with a readily accessible control. * Space Conditioning, Water Heating, and Plumbing System: § 110.0-§ 110.3: Certification.Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the California Energy Commission. * § 110.2(a):HVACEfficiency.Equipment must meet the applicable efficiency requirements in Table 110.2-Athrough Table 110.2-N. * § 110.2(b): Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. * § 110.2(c): Thermostats.All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. * § 110.3(c)3: Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank surface heat loss rating. § 110.3(c)6: Isolation Valves.Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour );and pool and spa heaters. * § 150.0(h)1: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Clearances.Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. § 150.0(h)3B: Liquid Line Drier.Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer’s instructions. § 150.0(j)1: Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in § 609.11 of the California Plumbing Code. * § 150.0(j)2: Insulation Protection.Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment` maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. § 150.0(n)1: Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must designate a space at least 2.5’ x 2.5’ x 7’ suitable for the future installation of a heat pump water heater, and meet electrical and plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no more than 2” higher than the base of the water heater § 150.0(n)3: Solar Water-heating Systems.Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts and Fans: § 110.8(d)3: Ducts.Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC).If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. § 150.0(m)1: CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 andANSI/SMACNA-006-2006 HVAC DuctConstruction Standards MetalandFlexible3rd Edition.Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼”, If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Buildingcavities and support platforms may contain ducts; ductsinstalledin these spaces must not becompressed.* § 150.0(m)2: Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field-Fabricated Duct Systems.Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: BackdraftDamper.Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers.Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. § 150.0(m)9: Protection of Insulation.Insulation must be protected from damage due tosunlight, moisture,equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating. § 150.0(m)10:Porous Inner Core Flex Duct.Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. § 150.0(m)11: Duct System Sealing and Leakage Test.When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. § 150.0(m)12: Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter. * 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(m)13: Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must EH•&)0SHU ton of nominal cooling capacity, and an air-handling unit fan efficacy ”0.45 watts per CFM for gas furnace air handlers and ”0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow •250 CFM per ton of nominal cooling capacity, and an air-KDQGOLQJXQLWIDQHIILFDF\”ZDWWVSHU&)0)LHOGYHULILFDWLRQWHVWLQJLVUHTXLUHGLQDFFRUGDQFHZLWK Reference Residential Appendix RA3.3. * Ventilation and Indoor Air Quality: § 150.0(o)1: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1.* § 150.0(o)1B: Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with §150.0(o)1C. § 150.0(o)1C: Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses .Single-family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. § 150.0(o)1G:Local Mechanical Exhaust.Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per §150.0(o)1Gvi. * § 150.0(o)1H&I:Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems.The airflow required per § 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by §150.0(o)1C. § 150.0(o)2: Field Verification and Diagnostic Testing.Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1G Pool and Spa Systems and Equipment: § 110.4(a): Certification byManufacturers.Anypool orspa heatingsystem orequipmentmustbe certified to haveall ofthefollowing: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistanceheating. * § 110.4(b)1: Piping.Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers.Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional Inlets and Time Switches for Pools.Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: PilotLight.Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p): Pool Systems and Equipment Installation.Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * Lighting: § 110.9: Lighting Controls and Components.All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.* § 150.0(k)1A:LuminaireEfficacy.Allinstalled luminaires must meet the requirementsin Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers;navigation lightingless than 5watts;and lighting internal to drawers,cabinets, and linen closetswith an efficacy of at least 45 lumens per watt. § 150.0(k)1B:Screwbased luminaires.Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1C: Recessed Downlight Luminaires in Ceilings.Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. § 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires.Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1E: Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. § 150.0(k)1F: Lighting Integral to Exhaust Fans.Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(k)1G:Screwbased luminaires.Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1H: Light Sources in Enclosed or Recessed Luminaires.Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1I: Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A:InteriorSwitches and Controls.All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B:InteriorSwitches and Controls.Exhaust fans must be controlled separately from lighting systems.* § 150.0(k)2A: Accessible Controls.Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned on and off. * § 150.0(k)2B: Multiple Controls.Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed to comply with § 150.0(k). § 150.0(k)2C: Mandatory Requirements.Lighting controls must comply with the applicable requirements of § 110.9. § 150.0(k)2D: Energy Management Control Systems.An energy management control system (EMCS) may be used to comply with dimming, occupancy, and control requirements if it provides the functionality of the specified control per § 110.9 and the physical controls specified in § 150.0(k)2A. § 150.0(k)2E: Automatic Shutoff Controls.In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with opaque fronts or doors must have controls that turn the light off when the drawer or door is closed. § 150.0(k)2F: Dimmers.Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall- mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LED light sources in these spaces must comply with NEMA SSL 7A. § 150.0(k)2K: Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or shelves, lighting in display cabinets, and switched outletsmust be controlled separately from ceiling-installed lighting. § 150.0(k)3A: Residential Outdoor Lighting.For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic time switch control) or an astronomical time clock. An energy management control system that provides the specified control functionality and meets all applicable requirements may be used to meet these requirements. § 150.0(k)4: Internallyilluminated address signs.Internally illuminated address signs must either comply with § 140.8 or consume no more than 5 watts of power. § 150.0(k)5: ResidentialGarages for Eight or More Vehicles.Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Solar Readiness: § 110.10(a)1: Single-family Residences.Single-family residences located in subdivisions with 10 or more single-family residences and where the application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b)-(e). §110.10(b)1A: Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet.* § 110.10(b)2: Azimuth.All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north. § 110.10(b)3A: Shading.The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment. * § 110.10(b)3B: Shading.Any obstructionlocated on the roof or any other part of the building that projects above a solar zone must be located at least twice the horizontal distance of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane.* § 110.10(b)4: StructuralDesign Loads on Construction Documents.For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. § 110.10(c): Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family residencesand central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system. § 110.10(d): Documentation.Acopy of the construction documents or a comparable document indicating the information from § 110.10(b)-(c) must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel.The main electrical service panel must have a minimum busbar rating of 200 amps. § 110.10(e)2: Main Electrical Service Panel.The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric.” Electric and Energy Storage Ready: 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(s) Energy Storage System (ESS) Ready. All single-family residences must meet all of the following:Either ESS-ready interconnection equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, or a dedicated raceway from the main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of 225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3’ of the main panelboard, with raceways installed between the panelboard and the switch location to allow the connection of backup power source. § 150.0(t) Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the furnace with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(u) Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(v) Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the dryer location with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” *Exceptions may apply. ROOM LOAD SUMMARY Project Name Date System Name Floor Area ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible PAGE TOTAL TOTAL * * Total includes ventilation load for zonal systems. Aralia Court Addition 8/18/2023 HVAC System (Main)74 1st Floor AdditionNew Main Addition 1181 2,336 17 48118172,336 1,817 48 48 118 118 17 17 2,336 2,336 1,817 1,817 ROOM LOAD SUMMARY Project Name Date System Name Floor Area ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible PAGE TOTAL TOTAL * * Total includes ventilation load for zonal systems. Aralia Court Addition 8/18/2023 HVAC System (ADU)321 1st Floor ADUNew ADU 1981 4,252 73 172198734,252 6,864 172 172 198 198 73 73 4,252 4,252 6,864 6,864 1 From: james dummit < Sent: Tuesday, August 6, 2024 10:39 AM To: Fire Department General <fdgeneral@slocity.org> Subject: Fwd: APARTMENTS Inspection Letter 07/31/2024 This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Arlan per your request to forward to you Begin forwarded message: From: noreply@imagetrend.com Subject: APARTMENTS Inspection Letter 07/31/2024 Date: July 31, 2024 at 4:36:46 PM PDT To: jdent1@charter.net Thank you for your cooperation with San Luis Obispo City Fire in keeping your business and our community safe! If you are not currently the property owner or manager at this location, or have any additional questions, please contact our Inspection Line at 805/783-7775. *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $209.54 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. This message is being sent from a HIPAA regulated electronic patient care records management system. Do not use unsecured e-mail to communicate any identifying patient information. *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 2160 Santa Barbara Avenue, San Luis Obispo, CA 93401 Phone: (805) 783 - 7780 Fax: (805) 543 - 8019 Fire Department Email: FDGeneral@slocity.org Hours: Monday - Friday, 8:00 am - 5:00 pm Business / Occupant:APARTMENTS Address:2074 Parker Work Phone:805-/54-1322 ext. 6 Contact Name:DUMMIT , Jim Email: Thank you for your cooperation with San Luis Obispo City Fire in keeping your business and our community safe! Correct the cited violation(s) by the "Reinspection Date" listed below to avoid further enforcement action including, but not limited to, chargeable re-inspection and/or Administrative Citation. You may request a review of the cited violations by the Department Director [Fire Chief] within 5 days of report issuance if noted violations do not create an immediate danger to health and safety (SLO M.C. 1.24.090). If you have any questions, please contact our Inspection Line at 805/783-7775. Date Completed:07/31/2024 Inspected By:Diepenbrock, Arlen Violation Count:8 Inspection Notes:The property is well kept, please continue to maintain the smoke, co2 alarms and dryer vents. 1) Please have "Fire Sprinkler" signage added in the following locations. Unit 120 on the restroom door. Unit 115 on the closet door that contains the riser. 2) Secure the water heater in 2074 with a strap. 3) There are no inspection documents uploaded on to the Compliance Engine or inspection tags on the fire sprinkler risers for 2078 or 2074 Parker. Please contact a certified fire sprinkler inspection contractor and have them perform a 5 year inspection of the three risers at 2078 & 2074 Parker. After a 5 year is performed an annual inspection is required for each riser with a 5 year inspection every 5 years. Please ensure that the contractor uploads the reports into the Compliance Engine under the address 2074, so that fire department staff can upload and review the reports. 4) Fire extinguishers on the property need to be serviced. Please have a licensed fire extinguisher contractor come out and service the extinguishers on the property. Be sure to include the fire extinguisher in the mechanical room of 2074. 5) Re install the cover to the circuit breaker box in the electrical room of 2078. San Luis Obispo City Fire Inspection Report Fire Department Information Business / Occupant Information Inspection Information Page 1 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 6 )Please ensure that each water flow valve on each riser is secured with a lock and chain so that the water flow valves cannot be tampered with. Additionally re-secure the lock and chain that prevents the back flow valves from being tampered with. 7) The FDC and the front of 2078 Parker needs to have the cover replaced. Please reach out to me when you are ready for re-inspection at adiepenb@slocity.org or at 805 503 2062. Don't hesitate to reach out if you have any questions. Violations Code Description Comments Reinspection Date 509.1 Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems or fire protection systems shall be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Please have "Fire Sprinkler" signage added in the following locations. Unit 120 on the restroom door. Unit 115 on the closet door that contains the riser. 08/29/2024 605.1 General. The design, construction, installation, operation, alteration, repair and maintenance of nonportable gasfired appliances and systems shall comply with the California Plumbing Code. The design, construction, installation, operation, alteration, repair and maintenance of nonportable solid fuel-fired and oil-fired appliances and systems shall comply with the provisions of this section and the California Mechanical Code. The construction and use of portable fuelfired appliances not connected to a fixed fuel piping system, such as blow torches, melting pots and weed burners, shall comply with this section. Please have the water heater in 2074 strapped to the wall. 08/29/2024 903.1 General. Automatic sprinkler systems shall comply with this section. There are no inspection documents uploaded on to the Compliance Engine or inspection tags on the fire sprinkler risers for 2078 or 2074 Parker. Please contact a certified fire sprinkler inspection contractor and have them perform a 5 year inspection of the three risers at 2078 & 2074 Parker. After a 5 year is performed an annual inspection is required for each riser with a 5 year inspection every 5 years. Please ensure that the contractor uploads the reports into the Compliance Engine so that fire department staff can upload and review the reports. 08/29/2024 906.1 Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, L, M, R-1, R-2, R-2.1, R-2.2, R-3.1, R-4 and S occupancies. Fire extinguishers on the property need to be serviced. Please have a licensed fire extinguisher contractor come out and service the extinguishers on the property. Be sure to include the fire extinguisher in the mechanical room of 2074. 08/29/2024 Page 2 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1- A:10-B:C. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. 7.Large and small family day-care homes shall be equipped with a portable fire extinguisher having a minimum 2-A:10-B:C rating. 8.Where required by California Code of Regulations, Title 19, Division 1. 9.Within 30 feet (9144 mm) of domestic cooking equipment located in a Group I-2. [California Code of Regulations, Title 19, Division 1, §3.29(a) through (d)] Portable Fire Extinguishing Equipment. (a)General. Portable fire extinguishers conforming to the requirements of California Code of Regulations, Title 19, Division 1, Chapter 3, shall be installed and maintained in accordance with guides established therein. (b)Special Coverage. Additional Class A, B and C units of adequate extinguishing potential shall be provided for any other hazard, as determined by the enforcing agency. (c)Group A Occupancies. (1)One additional Class 2-A unit shall be provided in Group A Occupancies as follows: (A)On each side of the stage or platform. Exception: Platforms 1000 square feet or less in area need have only one such extinguishing unit. (B)On each side of every fly gallery. (C)In basements beneath the stage or platform. (D)In every hallway or passageway leading to a dressing room. (E)In every property room, carpenter shop or similar workroom. (2)Not less than one 10-B:C unit (not less than 4-B:C for existing extinguishers in existing occupancies) shall be provided: (A)For each motor and fan room. (B)Adjacent to each switchboard on the stage or platform. (C)For each motion picture machine in projection rooms. Exception: One 20-B:C unit (not less than 8-B:C for existing extinguishers in existing occupancies) in each projection room may be accepted as providing substantially equal Page 3 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. protection. (3)The enforcing agency may allow modifications or deviations relative to the number and location of portable fire extinguishers as required by this section provided such authority finds that the basic intent of this section and the ease of accessibility to extinguishers is otherwise achieved. (d)Group R-2.1, R-3.1 and R-4 Occupancies. In Group R-2.1, R-3.1 and R-4 occupancies, a continuously attached garden hose, equipped with a water flow control nozzle, may be provided in lieu of one or more required fire extinguishers when acceptable to the enforcing agency. The location and length of such hose shall be as designated or approved by the enforcing agency. NOTE: It is recommended that, wherever possible, portable fire extinguishers be located adjacent to manual fire alarm sending stations. [California Code of Regulations, Title 19, Division 1, §565(a)] Selection of Fire Extinguishers. (a)The selection of extinguishers for a given situation shall be determined by the authority having jurisdiction in accordance with adopted codes or ordinances. The character of the fires anticipated, the construction and occupancy of the individual property, the vehicle or hazard to be protected, ambient-temperature conditions and other factors shall be considered. The number, size, placement and limitations of use of extinguishers required shall be determined by using California Code of Regulations, Title 19, Division 1, Sections 567 through 573. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. 603.2 .2 Open electrical terminations. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please re-install the cover to the electrical circuit breaker box in the electrical closet of 2078 Parker. 08/29/2024 907.8 Inspection, testing and maintenance. The maintenance and testing schedules and procedures for fire alarm and fire detection systems shall be in accordance with Sections 907.8.1 through 907.8.4 and NFPA 72. Records of inspection, testing and maintenance shall be maintained. see comments about the fire sprinkler riser inspection. 08/29/2024 Page 4 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 907.8 .4 Inspection, testing and maintenance. The building owner shall be responsible to maintain the fire and life safety systems in an operable condition at all times. Service personnel shall meet the qualification requirements of NFPA 72 for inspection, testing and maintenance of such systems. Records of inspection, testing and maintenance shall be maintained. Please ensure that each water flow valve on each riser is secured with a lock and chain so that the water flow valves cannot be tampered with. 08/29/2024 912.4 .2 Clear space around connections. A working space of not less than 36 inches (914 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided and maintained in front of and to the sides of wall-mounted fire department connections and around the circumference of free-standing fire department connections, except as otherwise required or approved by the fire code official. The FDC and the front of 2078 Parker needs to have the cover replaced. 08/29/2024 See Below For Inspection Checklist: Page 5 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. Fire Prevention Bureau Inspection Form Inspection Details Question Answer Notes Inspector Contact:Diepenbrock: (805) 503-2062 Email: adiepenb@slocity.org Ch. 3: General Requirements Question Answer Notes 311.2.2 - Vacant Buildings : All fire service systems continue to function as designed and proper fire separation is maintained. Yes 315.1 - Storage: Combustible material is placed or stored outside of 10 feet of any building or structure. Yes 304.1.2 - Vegetation Abatement: The property is free from weeds, debris, and combustibles. Yes 304.3.1 - Spontaneous ignition: Oily rags/materials susceptible to spontaneous ignition are stored in listed disposal containers, and properly disposed of daily. Yes 304.3.3 - Dumpsters 1.5 cubic yards and larger are kept a minimum of 5 feet from combustible walls/construction. Yes 308.1.4 - Open-flame cooking devices: Not used on combustible balconies or within 10 feet of combustible construction. Yes 310.3 - "No Smoking" signs: Posted in a conspicuous location where smoking is prohibited. Yes 315.3.1 - Ceiling clearance: Storage is kept 24" or more below ceilings in nonsprinklered areas, or at least 18" below head deflectors in sprinklered areas. Yes Ch. 4: Emergency Planning and Preparedness Question Answer Notes 403.1 - General Fire Safety and Evacuation Plan: Where required, evacuation drills shall be in accordance with Section 405 and employee training shall be in accordance with Section 406. N/A 403.9.1 - Group R-1 Fire Safety and Evacuation Plan: An approved fire safety and evacuation plan shall be prepared and maintained. N/A Ch. 5: Fire Service Features Question Answer Notes Page 6 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. FIRE LANE MARKING / OBSTRUCTION: Posted to ID fire apparatus access roads and prohibit obstruction. Minimum clearance is obtained at all times. Yes 504.4 - Roof access: No security barriers shall impede first responder access or egress to/from rooftops. Yes 505.1 - Address identification: Addressing is clearly visible from the property's fronting street, is at least 4 inches in height, and contrasts with its background. Yes 506.1 - Knox box required: Sprinklered commercial buildings are required to have Knox boxes. An approved lock shall be installed on gates or similar barriers where required by the fire code official. Yes 507.5.3 - Private fire service mains and water tanks: 1.-Private fire hydrants: Inspected annually and after each operation; flow test and maintenance annually. 2.-Fire service main piping: Inspection of exposed, annually; flow test every 5 years. 3.-Fire service main piping strainers: Inspection and maintenance after each use. N/A 507.5.5 - Clear space around hydrants: A 3-foot clear space shall be maintained around the circumference of fire hydrants, except as otherwise required or approved. N/A 509.1 - Fire protection signage: Rooms containing controls for A/C systems or fire protection systems are identified for the use of the fire department. No 509.1.1 - Utility identification: Gas shutoff valves, electric meters, service switches and other utility equipment shall be clearly marked to identify all units served. Yes Ch. 6: Building Services and Systems Question Answer Notes 605.1 - Installation/storage of fuel-fired appliances: Nonportable gas-fired appliances/systems-Complies with the this section and the CA Plumbing Code. Nonportable liquid fuel-fired appliances/systems shall comply with this section and the CA Mechanical Code. No 603.2.2 - Open electrical terminations: Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. No Page 7 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 603.4 - Clearance around electrical service equipment: The minimum required working space shall be not less than 30 inches in width, 36 inches in depth and 78 inches in height in front of electrical service equipment. Where the equipment is wider than 30 inches, the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Yes 603.4.1 - Electrical labeling for firefighters: Control panel rooms shall be marked with clear signage stating “ELECTRICAL ROOM” or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose, unless clearly evident. Yes 603.6 - Extension cords: For temporary use only and shall be listed and labeled in accordance with UL 817. Extension cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Yes 603.6.1 - Multiplug adapters: Extension cords shall be plugged directly into an approved receptacle, relocatable power tap or current tap and, except for approved multiplug extension cords, shall serve only one portable appliance. Yes 603.8 - Temporary wiring: Usage shall not exceed a period of 90 days and complies with the CA Electrical Code. Wiring is protected from physical damage and supported on insulators spaced not more than 10 feet apart. Yes 603.9 - Portable, electric space heaters: Plugged directly into an approved receptacle, not used with extension cords, and not operated within 3 feet of any combustible materials. Operated only in approved listed locations. 606.3.3 - Cleaning flammable grease: Hoods, grease-removal devices, fans, ducts and other appurtenances are cleaned every 6 months N/A 606.3.3.1 - Inspecting flammable grease systems: Hoods, grease-removal devices, fans, ducts and other appurtenances are inspected annually or as needed. N/A Page 8 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 610.1.1 - .2 - Dryer vents are free of combustible debris, routinely cleaned, and contain protective screening. Yes Ch. 7: Fire and Smoke Protection Features Question Answer Notes 705.1 - Maintenance of opening protectives: Opening protectives installed in fire-resistance-rated assemblies, smoke barriers and smoke partitions must be inspected and maintained in accordance with the code year the building was constructed. Yes Ch. 9: Fire Protection and Life Safety Systems Question Answer Notes 903.1 - Automatic sprinkler system compliance: Automatic sprinkler systems shall comply with this section. Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections 903.2.1 through 903.2.12 and Sections 903.2.14 through 903.2.21. No 906.1- .7 - Fire Extinguishers: One 2- A:10-B:C device 1-Every 75' of travel, 2- Mounted 3-5' high, 3-Unobstructed, and 4-Fully charged, serviced Annually, and tagged by a CA-State licensed extinguisher contractor. No 907.6.5 - Access to fire alarm devices for inspection and testing:Yes 907.8 - Testing of fire alarm and detection systems, and maintenance of records: No 907.8.4 - The building owner maintains the fire and life safety systems in an operable condition at all times. No 912.4.2 - Clear space around Fire Department Connections (FDCs):No 904.13: Kitchen Hood Suppression System: Inspected every 6 months by a CA-State Licensed C-16. N/A Ch. 10: Means of Egress Question Answer Notes 1004.9 - Occupant load signage: Public Assembly rooms/spaces have the occupant load posted in a conspicuous place, near the main exit or exit access doorway from the room or space. N/A Page 9 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 1010.1.2.1 Direction of exit door swing: Side-hinged swinging doors, pivoted doors and balanced doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons or a Group H occupancy. N/A 1010.2 Door operations: egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. N/A 1010.2.4 Locks and latches: Egress doors are free of key-locking or special knowledge hardware. N/A 1010.2.9 Panic and fire exit hardware: Provided as required for Assemblies, H & I occupancies. N/A 1008.2-2.3 Exit signs and emergency lights are operational at all times.N/A 1013.1 Exit identification: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel as required. N/A 1023.9 Stairway identification signs: A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than three stories designating the floor level, the terminus of the top and bottom of the interior exit stairway and ramp and the identification of the stairway or ramp. The signage shall state the story of, and the direction to, the exit discharge and the availability of roof access from the interior exit stairway and ramp for the fire department. N/A 1023.9.1 Signage requirements: Interior exit stairways and ramps.N/A 1031.1 + 4804.7 Exit obstruction: Exits are kept free of obstruction at all times.Yes *Operational Permits Question Answer Notes Are the occupant's business operations within the scope of their City and/or Hazardous Materials operational permit(s)? N/A Have all outstanding fees for the operational permit(s) been paid?N/A I have confirmed a currently active business license is publicly posted on site.N/A Ch. 23: Motor Fuel - Dispensing Facilities and Repair Garages Question Answer Notes Page 10 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 2311.2.2 - Waste oil, motor oil, and other Class IIIB liquids: Waste oil, motor oil and other Class IIIB liquids are stored in approved tanks/containers, which are allowed to be stored and dispensed from inside repair garages. N/A 2311.3 - Sources of Ignition: Sources of ignition shall not be located within 18" of the floor and shall comply with Chapters 3 and 35. N/A Ch. 50: Hazardous Materials - General Provisions Question Answer Notes 5001.3.3.4 - Spill mitigation: Spill containment systems or means to render a spill harmless to people or property shall be provided where a spill is determined to be a plausible event and where such an event would endanger people or property. N/A 5001.3.3.10 - Ventilation: Where ventilation is necessary to limit the risk of creating an emergency condition resulting from normal or abnormal operations, means of ventilation shall be provided. N/A 5003.2.5 - Empty containers and tanks: Empty containers and tanks previously used for the storage of hazardous materials are free from residual material and vapor as defined by DOTn, the Resource Conservation and Recovery Act (RCRA) or other regulating authority or maintained as specified for the storage of hazardous material. N/A 5003.2.6 - Hazardous materials maintenance: Equipment, machinery and required detection and alarm systems associated with hazardous materials shall be maintained in an operable condition. Defective containers, cylinders and tanks shall be removed from service, repaired or disposed of in an approved manner. Defective equipment or machinery shall be removed from service and repaired or replaced. Required detection and alarm systems shall be replaced or repaired where defective. N/A 5003.3 - Unlawful release of hazardous materials: Hazardous materials in any quantity have not/are not being released into a sewer, storm drain, ditch, drainage canal, creek, stream, river, lake or tidal waterway or on the ground, sidewalk, street, highway or into the atmosphere. N/A Page 11 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 5003.4 - Safety Data Sheets: Safety Data Sheets (SDS) are readily available on the premises for hazardous materials regulated by this chapter. Where a hazardous substance is developed in a laboratory, available information shall be documented. Exception: Designated hazardous waste. N/A 5003.5 - Hazard identification signs: Visible hazard identification signs as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. N/A 5003.5.1 - Hazardous materials markings: Individual containers, cartons or packages shall be conspicuously marked or labeled in an approved manner. Rooms or cabinets containing compressed gases shall be conspicuously labeled: “COMPRESSED GAS.” N/A 5003.7.1 - Smoking: Smoking shall be prohibited and “No Smoking” signs provided in Hazardous Materials areas. N/A 5003.9.3 - Protection from vehicles: Guard posts or other approved means shall be provided to protect storage tanks and connected piping, valves and fittings; dispensing areas; and use areas subject to vehicular damage in accordance with Section 312. N/A 5003.9.8 - Separation of incompatible materials: Incompatible materials in storage and storage of materials that are incompatible with materials in use shall be separated where the stored materials are in containers having a capacity of more than 5 pounds (2 kg), 0.5 gallon (2 L) or any amount of compressed gases. N/A 5003.10.1 - Valve protection: Hazardous material gas containers, cylinders and tanks in transit shall have their protective caps in place. Containers, cylinders and tanks of highly toxic or toxic compressed gases shall have their valve outlets capped or plugged with an approved closure device in accordance with Chapter 53. N/A Page 12 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 5004.2.1 - Spill control for hazardous material liquids: Rooms, buildings or areas used for the storage of hazardous material liquids in individual vessels having a capacity of more than 55 gallons (208 L), or in which the aggregate capacity of multiple vessels exceeds 1,000 gallons (3785 L), shall be provided with spill control to prevent the flow of liquids to adjoining areas. N/A 5004.2.2 - Secondary containment for hazardous material liquids and solids: Buildings, rooms or areas used for the storage of hazardous materials liquids or solids shall be provided with secondary containment where the capacity of an individual vessel or aggregate capacity of multiple vessels exceeds both of the following: Capacity of an individual vessel is > 55 gal. (liquid) or >550 lb. (solids), or the aggregate capacity of multiple vessels is > 1,000 gal. (liquid) or 10,000 lb. (solids). N/A Ch. 53: Compressed Gases Question Answer Notes 5303.5 - Securing compressed gas cylinders: Compressed gas containers, cylinders, tanks and systems shall be secured against accidental dislodgement and against access by unauthorized personnel in accordance with Sections 5303.5.1 through 5303.5.3. N/A 5306.1 - General: Medical gases at health care-related facilities intended for patient or veterinary care shall comply with Sections 5306.2 through 5306.5 in addition to other requirements of this chapter and Section 427 of the California Building Code. Personnel who handle medical gases and associated equipment and cylinders shall be trained on the use, safe handling and associated hazards. N/A Ch. 57: Flammable and Combustible Liquids Question Answer Notes 5704.1 - General: The storage of flammable and combustible liquids in containers and tanks shall be in accordance with this section and the applicable sections of Chapter 50. N/A Page 13 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 5704.2.3.2 - Label or placard: Tanks more than 100 gallons (379 L) in capacity, which are permanently installed or mounted and used for the storage of Class I, II or III liquids, shall bear a label and placard identifying the material therein. Placards shall be in accordance with NFPA 704. Exceptions: 1.Tanks of 300-gallon (1136 L) capacity or less located on private property and used for heating and cooking fuels in single-family dwellings. 2.Tanks located underground. N/A 5704.3.4.4 - Flammable/combustible liquid used for maintenance storage: In all occupancies, quantities of flammable and combustible liquids in excess of 10 gallons used for maintenance purposes and the operation of equipment shall be stored in liquid storage cabinets in accordance with Section 5704.3.2. Quantities not exceeding 10 gallons are allowed to be stored outside of a cabinet where in approved containers located in private garages or other approved locations. N/A 5704.3.5.2 - Storage pile heights: Containers having less than a 30-gallon capacity that contain Class I or II liquids shall not be stacked more than 3 feet or two containers high, whichever is greater, unless stacked on fixed shelving or otherwise satisfactorily secured. Containers of Class I or II liquids having a capacity of 30 gallons or more shall not be stored more than one container high. Containers shall be stored in an upright position. N/A 5704.3.5.3 - Storage distance from ceilings and roofs: Piles of containers or portable tanks shall not be stored closer than 3 feet (914 mm) to the nearest beam, chord, girder or other obstruction, and shall be 3 feet (914 mm) below sprinkler deflectors or discharge orifices of water spray or other overhead fire protection system. N/A 5705.3.2 - Bonding of vessels: Where differences of potential could be created, vessels containing Class I liquids or liquids handled at or above their flash points shall be electrically connected by bond wires, ground cables, piping or similar means to a static grounding system to maintain equipment at the same electrical potential to prevent sparking. N/A Ch. 61: Liquefied and Petroleum Gases Question Answer Notes Page 14 of 15 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $201.87 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. 6109.1 - General: Storage of portable LP-gas containers of 1,000 pounds (454 kg) or less, whether filled, partially filled or empty, at consumer sites or distribution points, and for resale by dealers or resellers shall comply with Sections 6109.2 through 6109.15.1. Exceptions: 1.LP-gas containers that have not previously been in LP-gas service. 2.LP-gas containers at distribution plants. 3.LP-gas containers at consumer sites or distribution points, which are connected for use. N/A 6109.15 LP-gas cylinder exchange for resale: 1.Cylinders shall be secured in a lockable, ventilated metal cabinet or other approved enclosure. 2.Cylinders shall be available only by authorized personnel or by use of an automated exchange system. 3.A sign is posted on the entry door of the business operating the cylinder exchange stating “DO NOT BRING LP-GAS CYLINDERS INTO THE BUILDING” or similar approved wording. 4.An emergency contact info sign shall be posted within 10 feet of the cabinet. N/A 6103.2.1 - Portable containers: Portable LP-gas containers, as defined in NFPA 58, shall not be used in buildings except as specified in NFPA 58 and Sections 6103.2.1.1 through 6103.2.1.7. N/A Signatures Question Answer Notes Rep/Responsible Party Signature: Inspector Signature: Page 15 of 15 1 From:Wong, Justin Sent:Tuesday, August 22, 2023 10:24 AM To:james dummit Subject:RE: 3100 Johnson Res curb permit Attachments:3100 Johnson Red Curb Permit.pdf Good Morning Jim, Thanks for checking in. It was great to meet you yesterday. Please see the aƩached pdf for your Red Curb Permit at 3100 Johnson Ave. The permit has already been approved, so you may go ahead and paint your curb upon receipt of this email. Ther e is informaƟon on permit tells you where you can purchase the paint. A printed copy of your permit will be mailed out at 2pm today, so you'll probably receive it in the mail tomorrow or Thursday. Please sign and return a hard copy of the permit at 919 Palm Street, San Luis Obispo, CA 93401. You may return it via mail or drop it off in-person during our public counter hours. Public Counter Hours: Monday/Wednesday – 1pm to 4pm Tuesday/Thursday – 9am to 12pm I hope the red curb helps your driveway situaƟon. If you ever run into any other transportaƟon issues, please feel free to reach out. Have a wonderful day, JusƟn Wong TransportaƟon Planner/Engineer I Public Works 919 Palm Street, San Luis Obispo, CA 93401-3218 E jwong@slocity.org T 805.781.7042 slocity.org -----Original Message----- From: james dummit < Sent: Tuesday, August 22, 2023 10:17 AM To: Wong, JusƟn <jwong@slocity.org> Subject: 3100 Johnson Res curb permit This message is from an External Source. Use cau Ɵon when deciding to open aƩachments, click links, or respond. ________________________________ Hi JusƟn ‘Thank you for your prompt response yesterday, regarding issuance of permit to red stripe curb at the above referenced address. I’m sending this email, as I didn’t receive any email yet - including said permit, and assumed maybe my email address was incorrect. Thanks Jim Dummit 2 City of San Luis Obispo Public Works - Transportation Division Red Curb Painting Permit The City of San Luis Obispo Public Works Department authorizes Jim Dummit to paint and maintain red curb at:3100 Johnson Ave The painting shall not extend beyond 3.5'to the left of the driveway when viewed from the roadway. The painting shall not extend beyond the limits as specified above and shall be performed as follows: 1. The curb top and face shall be painted to a neat edge line. 2. The area to be painted shall be clean and dry. 3. The paint shall be protected from pedestrians and vehicles until dry. 4. Any painting done in excess of the authorized limits shall be removed at the Permittee's expense. A quality red traffic curb paint must be used The paint is available at the following San Luis Obispo stores: Look for 'Safety Red'. - Sherwin Williams, 102 Cross Street Suite 130, (805) 596-0273 - paint code 6509-0069 - Sherwin-Williams, 3281 S. Higuera Street, (805) 543-3800 - paint code 6509-0069 After painting, please return the original signed permit to the following address: City of San Luis Obispo Transportation Engineering 919 Palm Street San Luis Obispo, CA 93401 Applicant's Signature Date 3.5' You are responsible for liability for personal injury and / or property damage caused by this work or your failure to do what you are obligated to do. If a claim of such liability is made against the City or any of its departments, officers, or employees, you shall, and hereby agree to, defend and indemnify the City and hold the City harmless from any claims, including costs of defense and attorney fees. I have read this permit and acknowledge receipt of the City of San Luis Obispo Red Curb Permit General Provisions and a copy of the section of the City of San Luis Obispo Municipal Code relating to the meanings of curb markings. These meanings apply to all vehicles, including the Permittee's. I agree to paint and maintain this curb as specified above. Agreement: (low quality paints will fade out and will not be enforceable). Attn: Transportation Intern The painting shall not extend beyond to the right of the driveway when viewed from the roadway. 5' 5' Official Use Only Application Approved By:Date: Painting in Compliance:Date: 1 From:Dowty, Philip Sent:Monday, February 26, 2024 2:35 PM To:Kevin Bates - Architect Cc:Jim Dummit Subject:RE: Stenger ADU - BLDG-2287-2023 Hello Kevin, I have one remaining question and want to ask if you could forward me a pdf of a response to plan check comments. Specifically, regarding my engineering comment #6, there was an existing tree identified for removal, but it is not longer shown on the plan. I was asking for the species of tree to be identified to verify if a removal permit was required or not. Is the tree still there? All my other engineering comments look satisfied. Thank you, Philip Dowty Engineering Consultant Mobile: 949.283.2270 Community Development E PDowty@slocity.org T 805.781.7171 slocity.org Stay connected with the City by signing up for e-notifications From: Kevin Bates - Architect <kevin@batesarchitecture.com> Sent: Friday, February 23, 2024 3:16 PM To: Dowty, Philip <PDowty@slocity.org> Cc: Jim Dummit < Subject: Stenger ADU - BLDG-2287-2023 This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Phil, Attached are the digital plans for the above referenced project, Thank you, 2 Kevin Bates, Architect Principal Bates Architecture P.O. Box 127, Arroyo Grande CA 93421 805.235.6378 www.batesarchitecture.com 1 From:Dowty, Philip Sent:Thursday, February 22, 2024 1:50 PM To:james dummit Subject:RE: 1382 Aralia Ct.; BLDG-2287-2023 Hello James, I see your resubmittal came in for the 1382 Aralia project. You helped me on the previous submittal by providing pdf’s of the plans; would you be able to provided the updated plans with the response to comments? If not, I should be in the office next week and can pick up the plans, as I explained earlier I work remotely and not normally in the office. You can call me on my cell phone anytime if you have questions. Thank you, Philip Dowty Engineering Consultant Mobile: 949.283.2270 Community Development E PDowty@slocity.org T 805.781.7171 slocity.org Stay connected with the City by signing up for e-notifications From: james dummit < Sent: Friday, January 26, 2024 11:29 AM To: Dowty, Philip <PDowty@slocity.org> Subject: Re: 1382 Aralia Ct.; BLDG-2287-2023 This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Hello Phillip attached please find pdf or re-submittal drawings for this project Respectfully, Jim Dummit On Jan 25, 2024, at 3:45 PM, Dowty, Philip <PDowty@slocity.org> wrote: 2 Dear Jim, I’m following up from a telephone message I just left. I’m a plan reviewer for the City Engineering Department, and mostly work remotely. I’m reaching out to ask if PDF’s of the resubmitted drawing could be made available for my review for your project on 1382 Aralia Court. If not, I should be in the office next week and can pick up the plans from the office. Please call me anytime, or reply to this email with any questions. Thank you, Philip Dowty Engineering Consultant Mobile: 949.283.2270 <image001.png> Community Development E PDowty@slocity.org T 805.781.7171 slocity.org <image002.png><image003.png><image004.png> Stay connected with the City by signing up for e-notifications 1 From:UBAC <ubac@slocity.org> Sent:Wednesday, September 13, 2023 11:14 AM To: Subject:RE: UB Adjustment Committee Form Submitted Hi Jim, I have been monitoring the usage at this property to be able to provide a response to your UBAC request. Per your invoice, it looks like the repair was made in July, however we have not seen a decrease in usage since the repair. We were out there on September 6th for your next bill and the usage is showing 36 units were used from August to September. Have there been any other water issues at the property? If not, the usage increase due to the leak did not exceed 50% of your average usage and no adjustment can be granted. Please let me know if there is any other information to consider, otherwise I will close out this request. Thank you, Maryanna Espejo-Moses pronouns she/her/hers UBAC Designee Public Utilities 879 Morro Street, San Luis Obispo, CA 93401-3218 E mespejo@slocity.org T 805.781.7569 slocity.org Stay connected with the City by signing up for e-notifications From: no-reply@slocity.org <no-reply@slocity.org> Sent: Monday, July 24, 2023 11:39 AM To: UBAC <ubac@slocity.org> Subject: UB Adjustment Committee Form Submitted Name: Jim Dummit Address: 3100 Johnson Ave Phone Number: Email: 2 Notes: Cu. hot water line leak that occurred, while away 4 weeks on vacation. Plumber replaced copper line failure, serving Bathroom 2. 1 From:Dowty, Philip Sent:Friday, February 23, 2024 3:58 PM To:james dummit Subject:Re: 1382 Aralia Bldg-2287-2023 Attachments:Mary Kay RC2C.pdf Received. Thanks Jim Sent from my iPhone On Feb 23, 2024, at 3:37 PM, james dummit < wrote: This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. ________________________________ Phil attached please find digital submittal drawings per your request. Please let me know you have received same thanks jim OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 Title SheetA0 PROJECT DESCRIPTION THIS PROJECT CONSISTS OF THE ADDITION OF A NEW ATTACHED ADU TO AN EXISTING 2,656 SINGLE FAMILY RESIDENCE. THE NEW ADU CONSISTS OF 321 SF NEW CONSTRUCTION AND INCLUDES 173 SF OF THE EXISTING RRESIDENCE TOTALING NET 494 SF ADU AREA. ALSO, THE ADDITION OF 74 SF TO THE EXISTING RESIDENCE DINING ROOM. GRADING ESTIMATE CUT: 26 CU FT. FILL: 0 CUFT. TREE REMOVAL ONE PROJECT DATA : PROPERTY 1382 Aralia Ct. San Luis Obispo, Ca. 93401 ASSESSORS PARCEL # 053-092-009 ZONING R-1 0CCUPANCY GROUP R-S TYPE OF CONSTRUCTION VB FIRE SPRINKLED Yes LOT SIZE 9,580 SF EXISTING BUILDING HEIGHT 25' PROPOSED ADU BUILDING HEIGHT 13' EXISTING FLOOR AREA EXISTING FLOOR AREA 2,656 SF EXISTING GARAGE 619 SF EXISTING AREA TOTAL 3,275 SF EXISTING FLOOR AREA RATIO 34 % (EXISTING FLOOR AREA RATIO/LOT AREA) PROPOSED FLOOR AREA PROPOSED ADU ADDITIONAL AREA 321 SF DINING ROOM ADDDITION 74 SF EXISTING RESIDENCE 2,656 SF EXISSTING GARAGE 619 SF TOTAL PROPOSED FLOOR AREA : 3,670 SF PROPOSED FLOOR AREA RATIO 38 % (PROPOSED FLOOR AREA RATIO/LOT AREA) SHEET INDEX: A0 TITLE SHEET A0.1 GENERAL NOTES A0.2 TITLE 24 ENERGY COMPLIANCE A0.3 TITLE 24 MANDATORY MEASURES A0.4 SITE PLAN / RETAINING WALL A0.5 EROSION CONTROL MEASURES A1 FLOOR PLAN A2 ELEVATIONS A3 SECTIONS A4 ROOF PLAN A5 ELECTRICAL PLAN A10 DETAILS A11 DEATILS STRUCTURAL: S1 GENERAL NOTES S2 FOUNDATION PLAN S2.1 FOUNDATION DETAILS S3 ROOF FRAMING PLAN S3.1 FRAMING DETAILS S3.2 FRAMING DETAILS S4 SHEARWALL PLAN S5 RETAINING WALL PLAN TOTAL SHEETS: 21 SITE Project: Stenger Residence x 93401 APN: Owner: MARY KAY STENGER 1382 Aralia Ct. San Luis Obispo, Ca. 93401 PROPOSED ADU FLOOR AREA PROPOSED ADU ADDITIONAL AREA 321 SF EXISTING RESIDENCE (BEDROOM) 173 SF TOTAL PROPOSED ADU FLOOR AREA : 494 SF 053-092-009 A A/C AIR CONDITIONING A.F.F. ABOVE FINISH FLOOR ALT. ALTERNATE AMT. AMOUNT APPROX. APPROXIMATE AVG. AVERAGE B BD. BOARD BTWN. BETWEEN BLDG. BUILDING BLK. / BLKG. BLOCK / BLOCKING C C.F.M. CUBIC FEET PER MINUTE CHG. CHANGE C.I. CAST IRON CLR. CLEAR/CLEARANCE CLG. CEILING CENTERLINE C.M.U. CONCRETE MASONRY UNIT COL. COLUMN CONC. CONCRETE CONSTR CONSTRUCTION C.O.T.G. CLEAN OUT TO GRADE CTR. CENTER CU. FT. CUBIC FOOT CU. IN. CUBIC INCH CU. YD. CUBIC YARD D DBL. DOUBLE DEG. DEGREE DEPT. DEPARTMENT DIAG. DIAGONAL DIA. DIAMETER DIM. DIMENSION DIV. DIVISION D.S. DOWNSPOUT DW. DUMBWAITER / DOWNSPOUT E (E) EXISTING EA. EACH ELEC. ELECTRIC ELEV. ELEVATION / ELEVATOR ENCL. ENCLOSURE EQ. EQUAL EQUIP. EQUIPMENT EXIST. EXISTING EXT. EXTERIOR F F.D FLOOR DRAIN F.G FINISH GRADE F.H. FIRE HYDRANT FIN. FINISH FLR. FLOOR FLUOR. FLUORESCENT F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD FS. FINISH SURFACE FT. FOOT FTG. FOOTING G GA. GAUGE GAL. GALLON GALV. GALVANIZED GYP. GYPSUM H H.B. HOSE BIBB HDR. HEADER HRDW. HARDWARE HORIZ. HORIZONTAL HP. HORSE POWER HT. HEIGHT I I.D. INSIDE DIAMETER IN. INCH INFO. INFORMATION INSUL. INSULATION INT. INTERIOR J JAN. JANITOR JCT. JUNCTION JT. OINT K KIT. KITCHEN L LAV.LAVATORY LB, POUND L.F. LINEAL FOOT LIN. LINEAR LT. LIGHT LT.WT. LIGHT WEIGHT M MAX. MAXIMUM M.B. MACHINE BOLT M.C. MEDICINE CABINET MECH. MECHANICAL MED. MEDIUM MEZZ, MEZZANINE MFR. / MFGR. MANUFACTURER MIN. MINIMUM MISC. MISCELLANEOUS MTL. METAL N (N) NEW N.G. NATURAL GRADE N.I.C. NOT IN CONTRACT NTS NOT TO SCALE O O/ BOARD O.C. ON CENTER O.D. OUTSIDE DIAMETER OPNG. OPENING ORIG. ORIGINAL OZ. OUNCE P PERP. PERPENDICULAR PL. PLATE P. LAM. PLASTIC LAMINATE PLY. WD. PLYWOOD PR. PAIR PROJ. PROJECT P.S.F. POUNDS PER SQUARE FOOT P.S.I. POUNDS PER SQUARE INCH PVMT. PAVEMENT P.T.D.F. PRESSURE TREATED DOUG FIR Q QT. QUART QTY. QUANTITY R R. RISER RAD. RADIUS RD. ROAD REF. REFRIGERATOR REINF. REINFORMENT REQ. REQUIRED RM. ROOM R.O. ROUGH OPENING R.T.S. REFER TO STRUCTURAL S SCHED. SCHEDULE S.C. SOLID CORE SECT. SECTION SHWR. SHOWER SHT. SHEET SIMM. SIMILAR SPEC(S). SPECIFICATION(S) SQ. SQUARE SQ. FT. SQUARE FEET S.S. STAINLESS STEEL ST. STREET STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURE SYM. SYMBOL T T. TREAD T.O.C TOP OF CONCRETE/CURB TO.C.B. TOP OF CATCH BASIN TEL. TELEPHONE TEMP. TEMPERATURE T&G TONGUE AND GROOVE THK. THICK TOIL. TOILET T.O.P. TOP OF PAVEMENT T.O.S. TOP OF SLAB T.O.W. TOP OF WALL TV TELEVISION TYP. TYPICAL U UNFIN. UNFINISHED U.N.O. UNLESS NOTED OTHERWISE UR. URINAL V V. VENT V.C.T. VINYL COMPOSITION TILE VENT. VENTILATE, VENTILATING VERT. VERTICAL V.T.R. VENT THRU ROOF W W.C. WATER CLOSET WD. WOOD W.H. WATER HEATER W.I. WROUGHT IRON WOM. WOMEN W.P. WATERPROOFING WSCT. WAINSCOT W/ WITH W/O WITHOUT ACRONYMS A.N.S.I. AMERICAN NATIONAL STANDARDS INSTITUTE A.S.T.M. AMERICAN SOCIETY FOR TESTING AND MATERIALS C.B.C. CALIFORNIA BUILDING CODE I.C.B.O. INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS N.F.P.A. NATIONAL FIRE PROTECTION ASSOCATION O.S.H.P.D. OCCUPATIONAL SAFETY AND HEALTH ACT U.F.C. UNIFORM FIRE CODE W.I.C. WOODWORK INSTITUTE OF CALIFORNIA ABBREVIATIONS DEFERRED SUBMITTALS NOTE : SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL.ENCROACHMENT PERMIT A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER AND FIRE SERVICE LATERALS, CURB, GUTTER, SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. AGENCIES / UTILITIES - CITY OF SLO PROJECT DIRECTORY DESIGNEROWNER VICINITY MAP - NTS PROJECT LOCATION 1382 Aralia Ct. San Luis Obispo, Ca. MARY KAY STENGER 1382 Aralia Ct. San Luis Obispop,CA 93950 STRUCTURAL ENGINEER SEPARATE PERMITS TITLE 24 ENERGY CALCULATIONS TIMOTHY CARSTAIRS CEA, CEPE CARSTAIRS ENERGY 1019 LOS OSOS VALLEY ROAD LOS OSOS, CA 93402 805.904.9048 PLANNING SAN LUIS OBISPO COMMUNITY DEVELOPMENT DEPARTMENT 919 PALM STREET SAN LUIS OBISPO, CA 93401 P: 805.781.7170 PUBLIC WORKS SAN LUIS OBISPO COMMUNITY DEVELOPMENT DEPARTMENT 919 PALM STREET SAN LUIS OBISPO, CA 93401 P: 805.781.7220 SLO CITY POLICE 1042 WALNUT AVE. SAN LUIS OBISPO, CA 93401 P: 805.781.7317 SLO FIRE DEPARTMENT 2160 SANTA BARBARA AVE. SAN LUIS OBISPO, CA 93401 P: 805.781.7380 ELECTRICITY PG&E 4325 HIGUERA STREET P: 805.546.5247 F: 805.546.5247 GAS SO. CAL GAS - BUILDER SERVICES 750 INDUSTRIAL WAY SAN LUIS OBISPO, CA 93401 P: 1.818.700.3693 ALL NEW CONSTRUCTION, ALTERATIONS AND ADDITIONS, DEMOLITIONS, INCLUDING CITY PROJECTS, SHALL BE REQUIRED TO DIVERT AT LEAST 65% OF WASTE AS RECYCLING FOR ALL PROJECT CONSTRUCTION AND DEMOLITION DEBRIS, CONSTRUCTION WASTE REDUCTION, DISPOSAL & RECYCLING JIM DUMMIT - DUMMIT ENTERPRISES 3100 JOHNSON AVE. SAN LUIS OBISPO, CA 93401 805-235-5038 ROLIN PARTNERSHIP ARCHITECTURAL ENGINEERING therolinpartnership@gmail.com 805-801-9445 FIRE SUPPRESSION PERMIT STATEMENT OF COMPLIANCE THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH AND MEETS THE CITY OF SAN LUIS OBISPO ADOPTED CODE AND ORDNANCE REQUIREMENTS INCLUDING, BUT NOT LIMITED TO, THE CALIFORNIA STATE ACCESSIBILITY STANDARDS AND I/WE WILL BE RESPONSIBLE FOR ALL CLARIFICATIONS DEEMED NECESSARY DURING THE CONSTRUCTION PHASES. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1 Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2 Operation and maintenance instructions for the following: a Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b Roof and yard drainage, including gutters and downspouts. c Space conditioning systems, including condensers and air filters. d Landscape irrigation systems. e Water reuse systems. 3 Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4 Public transportation and/or carpool options available in the area. 5 Educational material on the positive impacts of an interior relative humidity between 30—60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6 Information about water-conserving landscape and irrigation design and controllers which conserve water. 7 Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8 Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9 Information about state solar energy and incentive programs available. 10 A copy of all special inspection verifications required by the enforcing agency or this code. Operation and Maintenance Manual ______________________________ JIM DUMMIT - DESIGNER CODES: ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE (CBC). 2022 CALIFORNIA RESIDENTIAL CODE (CRC). 2022 CALIFORNIA MECHANICAL CODE (CMC). 2022 CALIFORNIA PLUMBING CODE (CPC). 2022 CALIFORNIA ELECTRICAL CODE (CEC). TITLE 24 OF THE CALIFORNIA ADMINISTRATIVE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBC) 2022 CALIFORNIA FIRE CODE (CFC). NFPA NATIONAL FIRE CODES ALL OTHER CODES AND ORDINANCES ADOPTED BY THE AGENCIES HAVING JURISDICTION OVER THIS PROJECT APPLICABLE CODES (E) ON SITE PARKING TO REMAIN, NO ADDITIONAL ON SITE PARKING FOR ADU REQUIRED PARKING ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER, SIDEWALK, OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR AND IN ACCORDANCE WITH THE MISSION STYLE SIDEWALK DISTRICT REQUIREMENTS. THE ADJOINING STREET AND SIDEWALK SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD, AND CONSTRUCTION DEBRIS AT THE END OF EACH WORKING DAY. ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE CITY UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATIONS. THE CURRENT ADOPTED STANDARDS ARE DATED AUGUST 2020. CONTACT PUBLIC WORKS INSPECTION HOTLINE AT 805 781-7554 WITH AT LEAST 48 HOURS NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION PUBLIC WORKS NOTES A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY, WITHIN OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITION, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDER DRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING, OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT OF WAY. A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. VICINITY MAP - NTS PROJECT LOCATION 1382 Aralia Ct. San Luis Obispo 1 1 1 ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. 2 2 GENERAL CONSTRUCTION REQUIREMENTS 1. CODES: ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING CODES: CODES: ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE (CBC). 2022 CALIFORNIA RESIDENTIAL CODE (CRC). 2022 CALIFORNIA MECHANICAL CODE (CMC). 2022 CALIFORNIA PLUMBING CODE (CPC). 2022 CALIFORNIA ELECTRICAL CODE (CEC). TITLE 24 OF THE CALIFORNIA ADMINISTRATIVE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBC) 2022 CALIFORNIA FIRE CODE (CFC). NFPA NATIONAL FIRE CODES ALL OTHER CODES AND ORDINANCES ADOPTED BY THE AGENCIES HAVING JURISDICTION OVER THIS PROJECT 2. DO NOT SCALE DRAWINGS!!! LARGER SCALE DRAWINGS SHALL TAKE PRECEDENCE OVER SMALLER SCALE ONES. DETAILS SHALL TAKE PRECEDENCE OVER PLANS AND SECTIONS. 3. DO NOT SCALE DRAWINGS!!! WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE OF DRAWINGS. DIMENSIONS ARE TO FACE OF FOOTING OR FACE OF STUDS, UNLESS OTHERWISE NOTED. 4. NOTES ON DRAWINGS SHALL TAKE PRECEDENCE OVER SEPARATE SPECIFICATIONS. 5. TYPICAL DETAILS SHALL APPLY TO ALL POSSIBLE CONDITIONS U.N.O. TYPICAL DETAILS AND TYPICAL NOTES ARE MINIMUM REQUIREMENTS TO BE USED WHEN SPECIFIC CONDITIONS ARE NOT USED OTHERWISE. 6. THIS SET OF PLANS SHALL BE ON THE JOB SITE AT ALL TIMES DURING CONSTRUCTION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS. NO CHANGES OR REVISIONS TO THE APPROVED PLANS OR SPECIFICATIONS SHALL BE PERMITTED UNLESS SUBMITTED TO & APPROVED BY THE BUILDING OFFICIAL. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS OR OMISSIONS FROM THE APPROVED PLANS & SPECIFICATIONS. (CBC 108.0). 7. ALL REASONABLE EFFORT SHALL BE MADE BY THE CONTRACTOR TO MINIMIZE NOISE AND OTHER ADVERSE IMPACTS ON THE OPERATION OF ADJACENT BUSINESSES AND RESIDENCES. ALL CONSTRUCTION PARKING AND DELIVERIES SHALL BE CONFINED TO THE SITE. 8. NO WORK SHALL BE PERFORMED FROM THESE CONTRACT DOCUMENTS UNTIL THEY ARE APPROVED BY THE APPROPRIATE REGULATORY AGENCIES. 9. VERIFICATION: THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL GRADES, FLOWLINES, POINTS OF CONNECTIONS AND DIMENSIONS PRIOR TO START OF CONSTRUCTION. ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES OR CHANGES IN PLANS. DEVIATIONS BY CONTRACTORS ARE DONE AT CONTRACTOR’S OWN RISK. IN THE EVENT OF ANY FURTHER DATA, INFORMATION OF CLARIFICATION OF THESE DRAWINGS IS REQUIRED, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT THE ARCHITECT & INFORM HIM OF ANY AMBIGUITY, INCONSISTENCY, DISCREPANCY, OR ERROR FOUND WITHIN THIS SET OF DRAWINGS BEFORE CONTINUING WITH CONST. 10. THE ISSUANCE OR GRANTING OF A PERMIT OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF THE CODES OR OF ANY OTHER ORDINANCE OF THIS JURISDICTION. PERMITS PRESUMING TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF THIS CODE OR OTHER ORDINANCES OF THIS JURISDICTION SHALL NOT BE VALID. (CBC SECT. 105.4) 11. ALL MATERIALS AND WORKMANSHIP SHALL BE NEW AND THE BEST OF ITS CLASS AND KIND. 12. IT IS THE CONTRACTOR’S RESPONSIBILITY TO INSURE THAT DETAILS REQUIRED BY THE VARIOUS CODES, BUT NOT SPECIFICALLY IN THESE PLANS, BE COMPLETED ACCORDING TO THE CODES. 13. CONTRACTOR SHALL FOLLOW ALL APPLICABLE INDUSTRIAL SAFETY REGULATIONS. THE LOCAL GOVERNING AGENCY, OWNER, ARCHITECT OR ENGINEER ARE NOT RESPONSIBLE FOR THE OVERALL COORDINATION & MANAGEMENT OF WORK. 14. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE SHOWN, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. EACH CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS AND PROCEDURES IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES. 15. WHERE A MANUFACTURER IS INDICATED FOR A SPECIFIC ITEM, INSTALL SUCH SPECIFIED ITEM PER MANUFACTURER’S RECOMMENDATIONS. 16. ALL TRADE NAMES SPECIFIED ON ANY DRAWINGS, MAY BE CHANGED FOR ANOTHER APPROVED EQUAL UPON THE EXPRESSED APPROVAL OF THE ARCHITECT. 17. ALL SUBCONTRACTORS, RELATED TRADES AND SUPPLIES SHALL COOPERATE AND PROVIDE AN OVERALL MANAGEMENT OF TIME AND WORK PROGRESS SO AS NO DELAYS OR LOSS OF TIME WILL OCCUR. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE OVERALL COORDINATION OF THE GENERAL CONTRACTOR. 18. CLEAN – UP: EACH CONTRACTOR SHALL CLEAN UP AND REMOVE FROM THE SITE ALL WASTE MATERIALS AND DEBRIS WHICH MAY BE ACCUMULATE ON THE SITE OR IN THE BUILDING. FINAL CLEAN – UP OF ALL SURFACES AND REMOVAL OF FOREIGN SUBSTANCES FROM THE JOB SITE IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 19. CONTRACTOR TO COORDINATE WITH THE OWNER(S) REGARDING THE SELECTION OF ANY ITEMS NOT SPECIFIED IN THESE PLANS, INCLUDING BUT NOT LIMITED TO: RESTROOM SPECIALTIES, CABINETRY, INTERIOR FINISHES, FLOOR FINISHES, HARDWARE AND ELECTRICAL FIXTURES. 20. BEFORE THE BUILDING MAY BE OCCUPIED, INSTALLATION CERTIFICATES FOR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE STANDARDS OR CERTIFICATES FOR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE STANDARDS OF CHAPTER 2 – 53, SHALL BE POSTED ADJACENT TO THE BUILDINGPERMIT(S). CERTIFICATES SHALL: A. IDENTIFY FEATURES REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE STANDARDS. B. INCLUDE A STATEMENT INDICATING THAT THE INSTALLED DEVICES CONFORM TO THE APPLIANCE STANDARDS AND THE REQUIREMENTS FOR SUCH DEVICES GIVEN ON THE PLANS AND SPECIFICATION APPROVED BY THE LOCAL ENFORCEMENT AGENCY. C. STATE THE NUMBER OF BUILDING PERMITS UNDER WHICH THE CONSTRUCTION OR INSTALLATION WAS PERFORMED. 21. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THEINSTALLER STATING THAT THE INSTALLATION CONFORMS WITH THE REQUIREMENTS OF CURRENT CALIF.ENERGY CODE TITLE 24. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER’S NAME AND MATERIAL IDENTIFICATION AND INSTALLED R – VALUE. 22. DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SHALL BE DESIGNED TO LIMIT AIR LEAKAGE INTO & FROM THE BUILDING ENVELOPE. A. MANUFACTURED DOORS AND WINDOWS SHALL HAVE AIR INFILTRATION RATES CERTIFIED BY THE MANUFACTURER AND NOT EXCEEDING THOSE SHOWN IN THE REGULATIONS. B. SITE CONSTRUCTION DOORS AND WINDOWS, EXTERIOR JOINT AND OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED, GASKETED, WEATHER –STRIPPED OR OTHERWISE SEALED. EXCEPTION: FIRE RATED DOORS AND WINDOWS, UNFRAMED GLASS DOORS: AND EXTERIOR ELEVATION SHAFT VENTILATION DAMPERS ARE ALSO NOT REQUIRED. 23. DUST CONTROL SHALL BE MAINTAINED TO THE SATISFACTION OF THE AGENCY OF RECORD. SAFETY GLAZING REQUIREMENTS HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREA, INCLUDING GLASS MIRRORS, IN HAZARDOUS LOCATIONS AS DEFINED IN SECTION 308.4 EXCEPTIONS: MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. IMPACT TEST. EXCEPT AS PROVIDED IN SECTIONS 308.4 THROUGH 308.4, ALL GLAZING SHALL PASS THE IMPACT TEST REQUIREMENTS OF SECTION 308.4. PLASTIC GLAZING. PLASTIC GLAZING SHALL MEET THE WEATHERING REQUIREMENTS OF ANSI Z97.1. GLASS BLOCK. GLASS-BLOCK WALLS SHALL COMPLY WITH SECTION 308.4 LOUVERED WINDOWS AND JALOUSIES. LOUVERED WINDOWS AND JALOUSIES SHALL COMPLY WITH SECTION 308.4 IMPACT TEST. WHERE REQUIRED BY OTHER SECTIONS OF THIS CODE, GLAZING SHALL BE TESTED IN ACCORDANCE WITH CPSC 16 CFR PART 1201. GLAZING SHALL COMPLY WITH THE TEST CRITERIA FOR CATEGORY II, UNLESS OTHERWISE INDICATED EXCEPTION: GLAZING NOT IN DOORS OR ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS SHALL BE PERMITTED TO BE TESTED IN ACCORDANCE WITH ANSI Z97.1. GLAZING SHALL COMPLY WITH THE TEST CRITERIA FOR CLASS A, UNLESS OTHERWISE INDICATED IN TABLE 308.3.1(1) IDENTIFICATION OF SAFETY GLAZING. EXCEPT AS INDICATED IN SECTION 2406.3.1, EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL BE IDENTIFIED BY A MANUFACTURER'S DESIGNATIONS SPECIFYING WHO APPLIED THE DESIGNATION, THE MANUFACTURER OR INSTALLER AND THE SAFETY GLAZING STANDARD WITH WHICH IT COMPLIES. HAZARDOUS LOCATIONS. THE LOCATIONS SPECIFIED IN SECTIONS 308.4 THROUGH 2406.4.7 SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS REQUIRING SAFETY GLAZING MATERIALS. GLAZING IN DOORS. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING, AND BIFOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION. EXCEPTIONS: 1. GLAZED OPENINGS OF A SIZE THROUGH WHICH A 3-INCH DIAMETER SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLAZING. 3. GLAZING MATERIALS USED AS CURVED GLAZED PANELS IN REVOLVING DOORS. 4. COMMERCIAL REFRIGERATED CABINET GLAZED DOORS. GLAZING ADJACENT TO DOORS. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM, EXPOSED EDGE IF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKING SURFACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. EXCEPTIONS: 1. DECORATIVE GLAZING. 2. WHERE THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND GLAZING. 3. WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN THIS APPLICATION SHALL COMPLY WITH SECTION 308.4 4. GLAZING IN WALLS ON THE LATCH SIDE OF AN PERPENDICULAR TO THE PLAN OF THE DOOR IN A CLOSED POSITION IN ONE AND TWO FAMILY DWELLINGS OR WITHIN DWELLING UNITS IN GROUP R-2. GLAZING IN WINDOWS. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS SHALL BE CONSIDERED A HAZARDOUS LOCATION: 1. THE EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER THAN 9 SQUARE FEET; 2. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18 INCHES ABOVE THE FLOOR; 3. THE TOP EDGE OF THE GLAZING IS GREATER THAN 36 INCHES ABOVE THE FLOOR; AND 4. ONE OR MORE WALKING SURFACE(S) ARE WITHIN 36 INCHES, MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE PLANE OF THE GLAZING. EXCEPTIONS: 1. DECORATIVE GLAZING. 2. WHERE A HORIZONTAL RAIL IS INSTALLED ON THE ACCESSIBLE SIDE(S) OF THE GLAZING 34 TO 38 INCHES ABOVE THE WALKING SURFACE. THE RAIL SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 1/2 INCHES IN CROSS-SECTION HEIGHT. 3. OUTBOARD PANES IN INSULATING GLASS UNITS OR MULTIPLE GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLASS IS 25 FEET OR MORE ABOVE ANY GRADE, ROOF, WALKING SURFACE OR OTHER HORIZONTAL OR SLOPED (WITHIN 45 DEGREES OF HORIZONTAL) SURFACE TO THE GLASS EXTERIOR. GLAZING IN GUARDS AND RAILINGS. GLAZING IN GUARDS AND RAILINGS, INCLUDING STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN-FILL PANELS, REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. GLAZING AND WET SURFACES. GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACING HOT TUBS, SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. EXCEPTION: GLAZING THAT IS MORE THAN 60 INCHES, MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, FROM THE WATER'S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL, OR SWIMMING POOL. GLAZING ADJACENT TO STAIRS AND RAMPS. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS, AND RAMPS SHALL BE CONSIDERED A HAZARDOUS LOCATION. EXCEPTIONS: 1. THE SIDE OF A STAIRWAY, LANDING OR RAMP THAT HAS A GUARD COMPLYING WITH THE PROVISIONS OF SECTIONS 1013 AND 1607.8, AND THE PLANE OF THE GLASS IS GREATER THAN 18 INCHES FROM THE RAILING. 2. GLAZING 36 INCHES OR MORE MEASURED HORIZONTALLY FROM THE WALKING SURFACE. GLAZING ADJACENT TO THE BOTTOM STAIR LANDING. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 60 INCHES ABOVE THE LANDING AND WITHIN 60 INCHES HORIZONTALLY OF THE BOTTOM TREAD SHALL BE CONSIDERED A HAZARDOUS LOCATION. EXCEPTION: GLAZING THAT IS PROTECTED BY A GUARD COMPLYING WITH SECTIONS 1015 AND 1607.8 WHERE THE PLANE OF THE GLASS IS GREATER THAN 18 INCHES FROM THE GUARD. FIRE DEPARTMENT ACCESS PANEL. FIRE DEPARTMENT GLASS ACCESS PANELS SHALL BE OF TEMPERED GLASS. FOR INSULATING GLASS UNITS, ALL PANES SHALL BE TEMPERED GLASS. CRC 2016, SECTION R308 GENERAL ARCHITECTURAL NOTES 1. PENETRATION OF FIRE-RESISTANT WALLS, FLOOR CEILINGS & ROOF CEILINGS SHALL BE PROTECTED AS REQUIRED IN 2016 CRC.flame 2. WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD & SMOKE-DEVELOPED INDEXES IN 2016 CRC CHAPTER7 3. MINIMUM HEADROOM CLEARANCE FOR STAIRWAY SHALL BE NO LESS THAN 6’-8". THIS MEASUREMENT IS FROM A PLANE TANGENT TO THE STAIRWAY THREAD NOSING. 4. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRWAY IS TO BE PROTECTED ON THE ENCLOSED SIDE WITH (1) ONE LAYER 5/8" TYPE ‘X’ GYP. WALLBOARD W/2 @ 16" O.C. NAILERS @ EDGE / FIELD (SOLID BLOCKED CONTINUOUS). 5. NO CONSTRUCTION MATERIALS CONTAINING ASBESTOS MAY BE USED ON THIS PROJECT. 6. ALL INTERIOR FINISHES, CHOSEN BY THE OWNER, MUST CONFORM TO THE REQUIREMENTS OF CHAPTER 7 OF THE 2016 CRC 7. THE OWNER IS TO SECURE THE PROPER OCCUPANCY PERMITS PRIOR TO OCCUPYING THE BUILDING. 8. ALL EXTERIOR SWINGING DOORS AND WINDOWS SHALL BE COMPLETELY WEATHER STRIPPED. 9. SAFETY GLAZING (PER 2016 CRC SECTION 308) IN AREAS SUBJECT TO HUMAN IMPACT. REFER TO THIS SHEET AND A-3.0 FOR ADDL. NOTES. 10. ALL EXTERIOR AND INTERIOR DOORS SHALL BE STANDARD HEIGHT (6’-8" ) U.N.O SET ALL FRAMES TRUE AND PLUMB. FIT ALL DOOR HARDWARE AND REMOVE FOR PAINTING AND STAINING. MAX. FLOOR LEVEL CHANGE IS 1/2" (INCLUDING THRESHOLD) @ ALL EXTERIOR DOORS TO LANDING U.N.O. 11. ALL STAIRWAYS SHALL HAVE A LANDING ( MEASURED IN THE DIRECTION OF TRAVEL) EQUAL TO OR GREATER THAN THE WIDTH OF THE STAIRWAY (TO 44" MAX.) 12. ALL WATER CLOSET COMPARTMENTS SHALL BE MIN. 30" CLEAR ( WIDTH) AND HAVE MIN. 24" CLEAR FROM FRONT OF THE WATER CLOSET. 13. WALL SURFACES BEHIND CERAMIC TILE OR OTHER FINISH MATERIALS SHALL BE CONSTRUCTED OF A MATERIAL NOT ADVERSELY AFFECTED BY WATER RESISTANT GYP. BOARD. NO W.R.G.B SHALL BE INSTALLED ON ANY CEILINGS. 14. ANY FLOOR AREAS TO RECEIVE CARPET AND PAD OR RESILIENT FLOORING (VINYL) SHALL BE LEFT CLEAN, DRY, AND DUST FREE. 15. ALL CONCEALED PLUMBING JOINTS SHALL BE NON – SLIP CONNECTIONS. 16. NEW WATER CLOSETS & ASSOCIATED FLUSHOMETER VALVES, IF ANY, SHALL HAVE A MAXIMUM FLOW PER GREEN BUILDING CODE NOTES THIS SHEET. 17. WATER PRESSURE IN BUILDINGS SHALL BE LIMITED TO 80 PSI OR LESS. 18. ALL PLUMBING WALLS SHALL BE 2X6 STUDS. 19. ALL WINDOWS AND SLIDING AND SWINGING GLASS DOORS SHALL BE DUAL GLAZED UNLESS NOTED OTHERWISE. 20. GAS VENTS AND NON COMBUSTIBLE PIPING, IN WALLS, PASSING THROUGH THREE FLOORS OR LESS, SHALL BE EFFECTIVELY DRAFT STOPPED AT EACH FLOOR OR CEILING. 21. ALL OPENABLE PORTIONS OF WINDOW SHALL HAVE BUG SCREENS, INCLUDING SLIDING GLASS DOORS, U.N.O. 22. EXTERIOR SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT, KEY OPERATED FROM OUTSIDE AND MANUALLY OPERATED FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 23. INACTIVE LEAF OF DOUBLE DOORS SHALL HAVE A HARDENED DEADBOLT TOP AND BOTTOM WITH 1/2" MIN. EMBEDMENT. 24. ALL CEILINGS ARE 9 FEET 0 INCHES (9'-0") HIGH UNLESS NOTES ARE SHOWN OTHERWISE ON PLANS. 25. ALL HALLWAYS TO BE A MIN. 44" WIDE FINISH TO FINISH. 26. PROVIDE GYPSUM BOARD (1/2" OVER FRAMING MEMBERS WITH 16" O.C. SPACING, 5/8" OVER FRAMING MEMBERS WITH 24" O.C SPACING) WITH TEXTURE OVER ASSEMBLY. VERIFY TEXTURE WITH OWNER. 27. FLOOR AND WALL FINISHES OF CLOSETS TO MATCH THAT OF THE ADJACENT ROOM U.N.O. 28. FOR VINYL OVER WOOD FLOORS, PROVIDE 3/8" PARTICLE BOARD UNDERLAYMENT. 29. NO GAS PIPING SHALL BE INSTALLED IN OR ON THE GROUND, UNDER ANY BUILDING OR STUCTURE. ALL EXPOSED GAS PIPING SHALL BE KEPT AT LEAST 6" ABOVE GRADE OR STRUCTURE. 30. ALL SINK FAUCET AERATORS SHALL HAVE A MAX. FLOW PER GREEN BUILDING CODE NOTES THIS SHEET. 31. SHOWER & TUB SHOWER COMBINATIONS SHALL HAVE INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. 32. WATER HEATER SHALL BE STRAPPED WITHIN 1/3 OF THE TOP AND BOTTOM OF THE HEATER AND THE STRAPS SHALL BE A MINIMUM OF 4" AWAY FROM THE WATER HEATER CONTROLS. 33. WHEN APPLIES, THE CALIFORNIA ENERGY CONSERVATION STANDARDS FOR RESIDENTIAL BUILDINGS HAVE BEEN REVIEWED AND THE BUILDING DESCRIBED ON THESE PAGES IS IN SUBSTANTIAL CONFORMANCE. THE COMPLY 24 COMPUTER PROGRAM HAS BEEN USED TO PERFORM CALCULATIONS. THIS PROGRAM IS AUTHORIZED BY THE CA. ENERGY COMMISSION FOR USE WITH THE SECOND GENERATION NON RESIDENTIAL BUILDING ENERGY EFFICIENCY STANDARDS. SECOND GENERATION RESIDENTIAL OCCUPANCIES, COMPLYING WITH THIS PROGRAM, CONFORM TO THE RESULTS PRODUCED BY THE PUBLIC DOMAIN POINT SYSTEM. 34. A CERTIFICATE OF CONSTRUCTION COMPLIANCE BASED ON OBSERVATION OF CONSTRUCTION SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND SHALL BE SIGNED BY THE CONTRACTOR AT THE TIME OF FINAL INSPECTION. 35. THE BUILDINGS DESCRIBED ON THE FOLLOWING PAGES ARE REQUIRED TO BE EQUIPPED WITH A FIRE SPRINKLER SYSTEM ( ATTACHED GARAGES INCLUDED). SHOP DRAWINGS SHALL BE SUBMITTED AND APPROVED BY THE CITY BUILDING AND FIRE DEPARTMENT PRIOR TO INSTALLATION OF THE SYSTEM. SYSTEM DESIGN SHALL MEET ALL REQUIREMENTS OF STATE FIRE MARSHALL, NFPA AND CITY REGULATIONS. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED AND APPROVED PRIOR TO ROUGH FRAMING INSPECTION. 36. ALL WINDOWS AND SLIDING GLASS DOORS SHALL MEET THE 1972 ANSI AIR INFILTRATION STANDARDS AND SHALL BE CERTIFIED AND LABELED. 37. INSULATION INSTALLER SHALL POST A SIGNED CERTIFICATE STATING THAT THE INSULATION CONFORMS WITH TITLE 24, PART 2, CHAPTER 2 – 53, AND THAT THE MATERIALS CONFORM WITH TITLE 20, CHAPTER 2, SUB- CHAPTER 4, ARTICLE 3. 38. FLUE DAMPER DEVICE IS TO BE PERMANENTLY BLOCKED OPEN IF A GAS LOG LIGHTER IS PROPOSED PER CURRENT CMC. 39. ALL HARDWARE, LIGHT FIXTURES (COLOR, TYPE AND FINISH), SWITCH PLATES, OUTLETS (COLOR AND TYPE) AND SHALL VERIFY ALL LOCATIONS AND HEIGHTS OF ALL OUTLETS, LIGHTING FIXTURES, ETC. SHALL BE CHOSEN BY THE OWNER. 40. ALL HARDWARE , INCLUDING (BUT NOT LIMITED TO) DOOR LATCHES, HINGES, CABINETRY HARDWARE, TYPES AND FINISHES SHALL BE CHOSEN BY THE OWNER. 41. ALL RESTROOM FIXTURES AND APPLIANCES SHALL BE CHOSEN BY THE OWNER. 42. MECHANICAL AND PLUMBING SYSTEMS ARE TO BE DESIGN-BUILD. CONTRACTOR TO SUBMIT ANY REQUIRED DRAWINGS TO THE AGENCY OF RECORD FOR REVIEW. 1. ALL PLUMBING SHALL CONFORM TO THE REQUIREMENTS OF THE CODES NOTED UNDER 'GENERAL CONSTRUCTION REQUIREMENTS' 2. REFER TO SPECIFICATIONS FOR PLUMBING MATERIALS AND FIXTURES. 3. THE FOLLOWING ABBREVIATIONS APPLY TO PLUMBING DRAWINGS: W: WASTEWATER PIPE V: V ENT PIPE VTR: VENT THROUGH ROOF CW: COLD WATER PIPE HW: HOT WATER PIPE FG: FUEL GAS PIPE WCO: WALL CLEANOUT (WITH ESCUTCHEON PLATE) COTG: CLEANOUT TO GRADE SOV: SHUT OFF VALVE HB: HOSE BIB (WITH APPROVED BACKFLOW DEVICE) TPRV: TEMPERATURE AND PRESSURE RELIEF VALVE (TERMINATE NOT APPROXIMATELY 6" ABOVE FLOOR DRAIN, AIMING DOWN WITH UNTHREADED END) 4. INSTALL PLUMBING FIXTURES AT MOUNTING HEIGHTS AND WITH ANCHORAGES RECOMMENDED BY MANUFACTURER. 5. PLUMBING CONTRACTOR SHALL CAREFULLY COORDINATE PLUMBING INSTALLATIONS WITH THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR, AND MECHANICAL CONTRACTOR TO ASSURE ADEQUATE CLEARANCES FOR ALL INSTALLATIONS WITHIN WALL AND FLOOR FRAMING SPACE AND BELOW SLABS. ANY CONFLICTS OR DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK. 6. GAS VENTS AND NON-COMBUSTIBLE PIPING IN WALLS, PASSING THROUGH THREE FLOORS OR LESS SHALL BE EFFECTIVELY DRAFT STOPPED AT EACH FLOOR OR CEILING. 7. WATER SOFTENERS ARE NOT PART OF THIS WORK. PLUMBING LOOPS ARE PROVIDED FOR WATER SOFTENERS, WHICH MAY BE EXCHANGE TYPE ONLY; IRRIGATION AND HOSE BIBS ARE NOT TO BE SERVED BY WATER SOFTENERS. 8. REFER TO 'C-SHEETS' PLAN FOR CONNECTION TO PUBLIC UTILITIES 9. THE CONTRACTOR SHALL SUBMIT PLANS AND CALCULATIONS FOR FIRE SPRINKLER SYSTEM PER NFPA 13-D STANDARDS AND SPECIFICATIONS, TO THE FIRE DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION, PER CALIF FIRE CODE SECT. 903.3. VERIFY THE LOCAL WATER MAIN FLOW RATE AND STATIC AND RESIDUAL PRESSURE PRIOR TO THE DESIGN. THE WATER SERVICE LINE FROM THE STREET TO THE WATER METER MUST BE SIZED TO PROVIDE ADEQUATE FLOW AND PRESSURE TO SUPPORT THE 13-D SYSTEM. 10. WHERE LOCAL STATIC WATER PRESSURE IS IN EXCESS OF 80 PSI, AN APPROVED TYPE PRESSURE REGULATOR PRECEDED BY AN ADEQUATE STRAINER SHALL BE INSTALLED AND THE STATIC PRESSURE REDUCED TO 80 PSI OR LESS, PER CPC SECT. 608.2. 11. PRESSURE TEST ALL WATER LINES AND GAS LINES PRIOR TO COVERING OR CLOSING IN CONSTRUCTION. 12. HOSE BIBS AND LAWN SPRINKLER SYSTEMS SHALL HAVE APPROVED, NON-REMOVABLE, BACKFLOW PREVENTION DEVICES PER CPC SEC. 603 13. WATER CONSERVATION PLUMBING FIXTURE REQUIREMENTS: REFER TO GREEN BUILDING CODE GENERAL NOTES THIS SHEET FOR MAX FLOW RATES. 14. HOT & COLD WATER LINES SHALL BE INSULATED AT POINT OF CONNECTION TO WATER HEATER FOR 5'-0" (EVEN THROUGH WALLS). 15. WATER HEATER SHALL BE STRAPPED OR ANCHORED TO RESIST DISPLACEMENT DUE TO EARTHQUAKE MOTION AS REQUIRED BY UMC. STRAPPING SHALL BE WITHIN 1/3 OF THE TOP AND BOTTOM OF THE HEATER AND THE STRAPS SHALL BE A MINIMUM OF 4" AWAY FROM THE WATER HEATER CONTROLS. 16. IN SHOWERS AND SHOWER-TUB COMBINATIONS, CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES PER CPC. 17. MINIMUM SIZE FOR SERVICE RISERS FOR STRUCTURES SHALL BE 1 - INCH DIAMETER. MATERIALS SHALL BE SCHEDULE 80 PVC OR TYPE "L" COPPER PIPE, MINIMUM. 18. HOT WATER, COLD WATER AND GAS PIPING SHALL BE BONDED TO MAIN ELECTRICAL PANEL IN AN APPROVED MANNER (CEC 250-80) 19. DRAINAGE PIPING SERVING FIXTURES WHICH HAVE FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION OF THE NEXT UPSTREAM MANHOLE COVER OF THE PUBLIC OR PRIVATE SEWER SERVING SUCH DRAINAGE PIPING SHALL BE PROTECTED FROM BACKFLOW OF SEWAGE BY INSTALLING AN APPROVED TYPE BACKWATER VALVE. FIXTURES ABOVE SUCH ELEVATION SHALL NOT DISCHARGE THROUGH THE BACKWATER VALVE. PER CPC SEC. 710.1 1. EACH SUB-CONTRACTOR SHALL THOROUGHLY EXAMINE AND BE FAMILIAR WITH THE DRAWINGS AND RELATED SPECIFICATIONS. 2. THE BID SUBMITTAL, BY THE SUB-CONTRACTOR, REPRESENTS THAT HE IS FAMILIAR WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, AND FULLY UNDERSTANDS THE FACILITIES, DIFFICULTIES AND RESTRICTIONS RELATED TO THE EXECUTION OF THE WORK FOR THIS PROJECT. 3. THE FAILURE OF OMISSION OF ANY SUB-CONTRACTOR TO RECEIVE OR EXAMINE ANY FORM, INSTRUMENT, OR OTHER DOCUMENT, OR TO VISIT THE SITE AS NECESSARY , AND BECOME ACQUAINTED WITH THE EXISTING CONDITIONS, SHALL IN NO WAY RELIEVE THEM FROM THEIR OBLIGATIONS WITH RESPECT TO THEIR BID OR THE CONTRACT. NO ADDITIONAL CHARGES WILL BE ALLOWED BECAUSE OF LACK OF SUCH KNOWLEDGE. THE SUBMISSION OF THE SUB-CONTRACTOR’S BID SHALL BE TAKEN AS PRIMA FACIE EVIDENCE OF COMPLIANCE WITH THIS CONDITION. 4. EACH SUB-CONTRACTOR SHALL BE TOTALLY FAMILIAR WITH PERTINENT RULES AND REGULATIONS OF GOVERNMENT BODIES HAVING JURISDICTION, STATE OF LABOR, MATERIALS MARKETS, AND SHALL MAKE DUE ALLOWANCE FOR ALL CONTINGENCIES. NO ADDITIONAL CHARGES WILL BE ALLOWED BECAUSE OF LACK OF SUCH KNOWLEDGE. THE SUBMISSION OF THE SUB-CONTRACTOR’S BID SHALL BE TAKEN AS PRIMA FACIE EVIDENCE OF COMPLIANCE WITH THIS CONDITION. 5. THE SUB-CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING HIS BIDS AND VERIFY ALL EXISTING CONDITIONS. 6. THE SUB-CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE BEGINNING ANY WORK AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 7. THE SUB-CONTRACTOR SHALL FIELD CERTIFY ALL ELEVATIONS, FLOW LINES AND POINTS OF CONNECTIONS BEFORE BEGINNING WORK AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 8. AT COMMENCEMENT OF WORK THE SUB-CONTRACTORS ACCEPTS RESPONSIBILITY FOR ALL EXISTING CONDITIONS. SUB-CONTRACTOR REPRESENTATIONPLUMBING NOTES 1. ALL DUCT WORK TO BE RIDGED SHEET METAL AND FLEX TYPE WITH R-5 INSULATION AND IN SIZES TO PROVIDE A COMPLETE, QUIET AIR FLOW SYSTEM 2. PLUMBING CONTRACTOR SHALL SIZE GAS LINE TO F.A.U. UNITS PER C.P.C. LATEST EDITION WITHIN 36" OF STUB-OUT. 3. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE SYSTEM INSTALLATION PER ALL CODES 4. ALL 90° TURNS IN FLEX DUCT SHALL HAVE SHEET METAL ELBOWS 5. ALL FLEX DUCT SHALL BE CLASS 1. FLEX DUCT TO BE USED AT CONNECTION TO GRILLS ONLY. SET BACK THERMOSTATS SHALL BE 'HONEYWELL' #T8082A OR APPROVED EQUAL 6. ALL SHEET METAL TO ATTIC SHALL BE WRAPPED WITH 1 1/2" FIBERGLASS BLANKET 7. ALL PLENUMS EXPOSED TO OUTSIDE SHALL BE LINED WITH 1" GLASS FIBER 8. ALL SUBSTITUTIONS TO BE APPROVED BY OWNER/ARCHITECT 9. SUBCONTRACTOR SHALL PROVIDE DUCT AND REGISTER LAYOUT FOR ARCHITECT APPROVAL 10. SHEET METAL DUCTS SHALL BE FABRICATED IN ACCORDANCE WITH C.M.C. AND S.M.A.C.N.A. STANDARDS 11. ALL PENETRATIONS THROUGH ROOF SHALL BE GUARANTEED TO BE WEATHERPROOF 12. ALL MECHANICAL WORK SHALL CONFORM WITH THE CURRENT CALIFORNIA MECHANICAL CODE (W/ AMENDMENTS) 13. REFER TO SPECIFICATIONS FOR HEATING AND VENTILATION APPLICATIONS. 14. MODIFICATIONS TO THE SYSTEM LAYOUT INDICATED ON THE DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT IN THE FORM OF SHOP DRAWING FOR APPROVAL. 15. CLEARANCES FOR FURNACE AND WATER HEATER SHALL BE PER MANUFACTURERS' LISTING. THE FURNACE AND WATER HEATER CLOSET MUST BE INSTALLED IN A ROOM OR SPACE HAVING A VOLUME AT LEAST 12 TIMES THE TOTAL VOLUME OF THE FURNACE, PER CMC SECT. 304. PROVIDE MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS PER TABLE 3-1 OF THE CMC CHAPTER 3. 16. ADJUST EQUIPMENT, DUCTS, NECKS, GRILLES AND REGISTERS FOR PROPER VOLUME AND DISTRIBUTION OF AIR: AIR VELOCITY PASSING THROUGH NECKS SHALL NOT EXCEED 800 FPM ON LOW OUTPUT SETTING. 17. GAS VENTS AND NON-COMBUSTIBLE PIPING IN WALLS PASSING THROUGH THREE FLOORS OR LESS SHALL BE EFFECTIVELY DRAFT STOPPED AT EACH FLOOR OR CEILING PER C.B.C. 18. THE POINT OF DISCHARGE OF MECHANICAL VENTING SYSTEMS SHALL BE AT LEAST 3 FEET FROM ANY OPENING FROM WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING, PER C.B.C. 19. CLOTHES DRYER SHALL BE VENTED DIRECTLY TO THE OUTSIDE PER C.M.C. 20. MECHANICAL CONTRACTOR SHALL CAREFULLY COORDINATE MECHANICAL INSTALLATIONS WITH THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND PLUMBING CONTRACTOR TO ASSURE ADEQUATE CLEARANCES FOR ALL INSTALLATIONS WITHIN WALL AND FLOOR FRAMING SPACE. ANY CONFLICTS OR DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK. 21. WATER HEATER OR FURNACE EXHAUST FLUES RUNNING UP WALLS SHALL BE TYPE B, DOUBLE WALL METAL VENTS, U.L. LISTED, INSTALLED WITH FULL CLEARANCE FROM COMBUSTIBLE MATERIALS AS RECOMMENDED BY VENT MANUFACTURER. 22. WHERE POSSIBLE, COMBINE VENT RUNS TO LIMIT PENETRATIONS THROUGH ROOF. 23. THE RETURN AIR PLENUM SERVING THE MECHANICAL EQUIPMENT MUST BE FULLY DUCTED FROM THE EQUIPMENT TO THE CONDITIONED SPACE. DROP CEILINGS, WALL CAVITIES, & EQUIPMENT PLATFORMS MAY NOT BE USED AS PLENUMS. 24. CLOTH BACKED DUCT TAPE IS NO LONGER PERMITTED TO BE USED AS THE SOLE CONNECTION FOR MECHANICAL DUCTING. DUCT TAPE, AS A MINIMUM, MEETING THE REQUIREMENTS OF UL181, 181A OR 181B, SHALL BE USED OR ADDITIONAL DUCT ATTACHMENT DEVICES SUCH AS TIE RAPS OR MASTIC WILL BE REQUIRED FOR INSTALLING MECHANICAL DUCTING. PROVIDE COMBUSTION AIR TO MECH. ROOM, EACH OPENING SHALL HAVE A FREE AREA OF NOT LESS THAT 1 SQ. IN. PER 4,000 BTU/H OF THE TOTAL INPUT RATING OF ALL EQUIPMENT IN THE ENCLOSURE, BUT NOT LESS THAN 100 S.Q. IN., 50% @ BOTTOM & 50% @ TOP. 25. FOR HABITABLE SPACES WITHOUT DIRECT OUTSIDE VENTILATION PROVIDE MECHANICAL VENTILATION WITH A MIN. OF TWO AIR CHANGES PER HOUR (ACH) PER CBC SECT. 1203.1 AND THE CMC. 26. WHERE ROOMS AND SPACES W/O OPENINGS TO THE OUTDOORS ARE VENTILATED THROUGH AN ADJOINING ROOM, THE OPENING TO THE ADJOINING ROOM SHALL BE UNOBSTRUCTED AND SHALL HAVE AN AREA OF NOT LESS THAN 8% OF THE FLOOR AREA OF THE INTERIOR ROOM OR SPACE, BUT NOT LESS THAN 25 S.F., PER CBC SECT. 1203.4.1.1. MECHANICAL NOTES GREEN BUILDING STANDARDS CODE GENERAL NOTES 1. Plumbing fixtures and fixture fittings on the plans shall comply with the following flow rates: a. Water Closets – 1.28 GPF b. Urinals – 0.5 GPF c. Wall-mounted urinal – 0.125 GPF d. Single showerhead – 1.8 GPM at 80psi e. Multiple showerheads – COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GPM @ 80 PSI OR ONLY ONE SHOWER OUTLET IS TO BE IN OPERATION AT A TIME. f. Lavatory faucets – 1.2 GPM at 60psi g. Lavatory faucets in public use areas – 0.5 GPM at 60psi h. Metering faucets - .25 gallons per cycle i. Kitchen faucets – 1.8 GPM at 60psi. (4.303.1) 2. Annular spaces around pipes, electrical cables, conduits, or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry, or a similar method acceptable to the enforcing agency. (4.406.1) 3. Fireplaces shall be direct vent sealed combustion type. Indicate on the plans the manufacturer name and model number. (4.503.1) 4. At the time of rough installation, during storage on the construction site, and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheetmetal, or other acceptable methods to reduce the amount of water, dust and debris which may enter the system. (4.504.1) 5. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19% moisture content. Insulation products which are visibly wet or have high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. (4.505.3) 6. All mechanical exhaust fans in rooms with a bathtub or shower shall comply with the following: a. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. b. Fans must be controlled by a readily accessible humidistat unless functioning as a component of a whole house ventilation system. Humidity control shall be capable of adjustment between a relative humidity range of 50% and 80%. (4.506.1) 7. Adhesives, sealants and caulks shall meet or exceed the standards outlined in Section 4.504.2.1 and comply with the VOC limits in Tables 4.504.1 and 4.504.2 as applicable. (4.504.2.1) 8. Paints and coatings shall meet or exceed the standards outlined in Section 4.504.2.2 and comply with the VOC limits in Table 4.504.3. (4.504.2.2) 9. Aerosol paints and coatings shall meet or exceed the standards outlined in Section 4.504.2.3. (4.504.2.3) 10. All carpet installed in the building interior shall meet all the testing and product requirements of one of the following: a. Carpet and Rug Institute’s Green Label Plus Program OR b. California Department of Public Health Standard Method for the testing of VOC Emissions (Specification 01350) OR c. NSF/ANSI 140 at the Gold Level OR d. Scientific Certifications Systems Indoor Advantage Gold (4.504.3) 11. All carpet cushion installed in the building interior shall meet the requirements of the Carpet and Rug Institute Green Label Program. Carpet adhesives shall not exceed a VOC limit of 50 g/L. (4.504.3.1, 4.504.3.2) 12. A minimum of 80% of floor area receiving resilient flooring shall comply with one of the following: a. Products certified as a Low-Emitting Material in the CHPS High Performance Products Database, OR b. Products certified under UL GREENGUARD Gold (Formerly the Greenguard Children & Schools program), OR c. RFCI FloorScore program, OR d. Meet the California Department of Public Health Standard Method for the testing of VOC Emissions (Specification 01350) (4.504.4) 13. Composite wood products (hardwood plywood, particle board, and MDF) installed on the interior or exterior of the building shall meet or exceed the standards outlined in Table 4.504.5. Verification of compliance with these sections must be provided at the time of inspection. (4.504.5) 5.410.4 Testing and adjusting. New buildings less than 10,000 square feet Testing and adjusting of systems shall be required for new buildings less than 10,000 square feet or new systems to serve an addition or alteration subject to Section 303.1. 5.410.4.2 Systems Develop a written plan of procedures for testing and adjusting systems. Systems to be included for testing and adjusting shall include, as applicable to the project: 1 Renewable energy systems. 2 Landscape irrigation systems. 3 Water reuse systems. 5.410.4.3 Procedures Perform testing and adjusting procedures in accordance with manufacturer’s specifications and applicable standards on each system. 5.410.4.3.1 HVAC balancing In addition to testing and adjusting, before a new space-conditioning system serving a building or space is operated for normal use, balance the system in accordance with the procedures defined by the Testing Adjusting and Balancing Bureau National Standards; the National Environmental Balancing Bureau Procedural Standards; Associated Air Balance Council National Standards or as approved by the enforcing agency. 5.410.4.4 Reporting After completion of testing, adjusting and balancing, provide a final report of testing signed by the individual responsible for performing these services. 5.410.4.5 Operation and maintenance (O & M) manual Provide the building owner or representative with detailed operating and maintenance instructions and copies of guaranties/warranties for each system. O & M instructions shall be consistent with OSHA requirements in CCR, Title 8, Section 5142, and other related regulations. 5.410.4.5.1 Inspections and reports Include a copy of all inspection verifications and reports required by the enforcing agency.I 24. THE BID SUBMITTAL, BY THE CONTRACTOR, REPRESENTS THAT HE IS FAMILIAR WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, AND FULLY UNDERSTANDS THE FACILITIES, DIFFICULTIES AND RESTRICTIONS RELATED TO THE EXECUTION OF THE WORK FOR THIS PROJECT. 25. SUB-CONTRACTOR SHALL PROVIDE TITLE 24-APPROVALS & GUARANTEES FOR ALL ASSEMBLIES 26. IN THE EVENT OF FOUND MATERIALS SUSPECTED TO BE OF AN ARCHAEOLOGICAL OR PALEONTOLOGICAL NATURE, ALL GRADING AND EXCAVATION SHALL CEASE IN THE IMMEDIATE AREA AND THE APPROPRIATE AUTHORITIES TO BE NOTIFIED BY THE CONTRACTOR. ANY FINDS SHALL BE LEFT UNTOUCHED UNTIL AN EVALUATION BY A QUALIFIED ARCHAEOLOGIST OR PALEONTOLOGIST IS PERFORMED. 27. THIS PERMIT SHALL EXPIRE BY LIMITATION IF WORK AUTHORIZED UNDER THIS PERMIT IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE OR IF THE WORK IS SUSPENDED FOR A PERIOD EXCEEDING 180 DAYS AFTER WORK HAS COMMENCED. REFER TO LOCAL JURISDICTION FOR SPECIFIC TIME PERIODS. 28. ALL CONTRACTORS AND SUB-CONTRACTORS MUST HAVE ON FILE WITH THE BUILDING DEPARTMENT, A LIST OF ALL SUCH CONTRACTORS AND SUB-CONTRACTORS WITH APPROPRIATE CURRENT CITY BUSINESS LICENSE NUMBERS. 29. ALL SUB TRADES AND MATERIAL SUPPLIERS SHALL HAVE, IN PLACE, AN APPROVED OSHA SAFETY PLAN PRIOR TO PERFORMING WORK OR VISITING THE BUILDING SITE. OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 General NotesA0.1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 GENERAL INFORMATION 01 Project Name Aralia Court Addition 02 Run Title Title 24 Analysis 03 Project Location 1382 Aralia Court 04 City San Luis Obispo 05 Standards Version 2022 06 Zip code 93401 07 Software Version EnergyPro 9.1 08 Climate Zone 5 09 Front Orientation (deg/ Cardinal)225 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed Addition 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)395 15 Number of Stories 2 16 Existing Cond. Floor Area (ft 2)2656 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft 2)3051 19 Glazing Percentage (%)31.47% 20 ADU Bedroom Count 1 ADDITION ALONE - Project Analysis Parameters 01 02 03 04 05 06 Existing Area (excl. new addition) (ft2) Addition Area (excl. existing) (ft2)Total Area (ft2)Existing Bedrooms Addition Bedrooms Total Bedrooms 2656 395 3051 3 1 4 ADDITION ALONE - ACCESSORY DWELLING UNIT (ADU) PROJECT ANALYSIS PARAMETERS 01 02 03 04 05 06 07 08 Zone Name Existing Area (excl. new addition) (ft 2) ADU Area (excl. existing) (ft 2)Total Area (ft 2)Existing Bedrooms Addition Bedrooms Total Bedrooms Attached vs. Detached New ADU 2656 395 3051 3 1 4 Attached 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0 22.59 0 27.74 0 -5.15 Space Cooling 0 1.63 0 1.2 0 0.43 IAQ Ventilation 0 5.21 0 5.21 0 0 Water Heating 0 157.6 0 141.99 0 15.61 Self Utilization/Flexibility Credit Efficiency Compliance Total 0 187.03 0 176.14 0 10.89 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 6.91 0 6.91 Appl. & Cooking 0 113.61 0 113.42 Plug Loads 0 97.64 0 97.64 Outdoor Lighting 0 13.7 0 13.7 TOTAL COMPLIANCE 0 418.89 0 407.81 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 ENERGY USE INTENSITY Standard Design (kBtu/ft 2 -yr)Proposed Design (kBtu/ft 2 -yr)Compliance Margin (kBtu/ft 2 -yr)Margin Percentage Gross EUI 1 82.51 78.57 3.94 4.78 Net EUI 2 82.51 78.57 3.94 4.78 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •New ductwork added is less than 25 ft. in length •Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Indoor air quality ventilation •Kitchen range hood •Verified Refrigerant Charge •Airflow in habitable rooms (SC3.1.4.1.7) •Verified heat pump rated heating capacity •Wall-mounted thermostat in zones greater than 150 ft2 (SC3.4.5) •Ductless indoor units located entirely in conditioned space (SC3.1.4.1.8) •Duct Sealing required if a duct system component, plenum, or air handling unit is altered ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Status New Main Addition Conditioned HVAC System (Main)1 74 8 DHW Sys 1 New New ADU Conditioned HVAC System (ADU)2 321 9 DHW Sys 1 New 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg)Wall Exceptions Status Rear Wall New Main Addition R-15 Wall 45 Back 99 28.7 90 Extension New Right Wall New Main Addition R-15 Wall 135 Right 63 14 90 Extension New Front Wall New ADU R-15 Wall 225 Front 40 0 90 Extension New Left Wall New ADU R-15 Wall 315 Left 168 32.1 90 Extension New Rear Wall 2 New ADU R-15 Wall 45 Back 184 0 90 Extension New Right Wall 2 New ADU R-15 Wall 135 Right 168 18 90 Extension New N Wall New ADU R-15 Wall 0 n/a 40 10.5 90 Extension New E Wall New ADU R-15 Wall 90 n/a 40 21 90 Extension New Interior Surface New Main Addition>>New ADU R-15 Wall1 n/a n/a 100 0 n/a New Interior Surface 2 New Main Addition>>New ADU R-15 Wall1 n/a n/a 100 0 n/a New Roof New Main Addition R-30 Roof Attic n/a n/a 74 n/a n/a New Roof 2 New ADU R-30 Roof Attic n/a n/a 321 n/a n/a New ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic New Main Addition Attic RoofNew Main Addition Ventilated 5 0.1 0.85 No No Attic New ADU Attic RoofNew ADU Ventilated 5 0.1 0.85 No No 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading W7 Window Rear Wall Back 45 1 10.7 0.3 NFRC 0.35 NFRC Bug Screen D5 Window Rear Wall Back 45 1 18 0.3 NFRC 0.35 NFRC Bug Screen W5 Window Right Wall Right 135 1 10 0.3 NFRC 0.35 NFRC Bug Screen W6 Window Right Wall Right 135 1 4 0.3 NFRC 0.35 NFRC Bug Screen D1 Window Left Wall Left 315 1 23.3 0.3 NFRC 0.35 NFRC Bug Screen W4 Window Left Wall Left 315 1 8.8 0.3 NFRC 0.35 NFRC Bug Screen D2 Window Right Wall 2 Right 135 1 18 0.3 NFRC 0.35 NFRC Bug Screen W3 Window N Wall 0 1 10.5 0.3 NFRC 0.35 NFRC Bug Screen W1 Window E Wall 90 1 10.5 0.3 NFRC 0.35 NFRC Bug Screen W2 Window E Wall 90 1 10.5 0.3 NFRC 0.35 NFRC Bug Screen SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab New Main Addition 74 18 none 0 80%No Slab 2 New ADU 321 80 none 0 80%No 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco R-15 Wall1 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Other Side Finish: Gypsum Board Attic RoofNew Main Addition Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofNew ADU Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 R-30 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Not Required Not Required N/A n/a n/a 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name Heating Element Type Tank Type #ofUnits Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location DHW Heater 1 Gas Consumer Instantaneo us 1 0 UEF 0.93 Btu/Hr 200000 0 n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System (Main)1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 n/a 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System (ADU)2 Heat pump heating cooling Heat Pump System 2 1 Heat Pump System 2 1 n/a n/a Setback HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Electric 1 HSPF-3.41 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER/SEER 11.7 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationEfficiency Type HSPF / HSPF2 / COP Cap 47 Cap 17 Efficiency Type SEER / SEER2 EER / EER / CEER Heat Pump System 2 VCHP-ductless 1 HSPF 8.8 12000 8000 EERSEER 15 12.2 Not Zonal Single Speed Heat Pump System 2-hers-htpump 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 2-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Name Certified Low-Static VCHP System Airflow to Habitable Rooms Ductless Units in Conditioned Space Wall Mount Thermostat Air Filter Sizing &amp; Pressure Drop Rating Low Leakage Ducts in Conditioned Space Minimum Airflow per RA3.3 and SC3.3.3.4.1 Certified non-continuous Fan Indoor Fan not Running Continuously Heat Pump System 2 Not required Required Required Required Not required Not required Not required Not required Not required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Existing (not specified) Air Distribution System 1-hers-dist HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Not Required 0 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM) Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE Includes Fault Indicator Display? HERS Verification Status SFam ADU IAQVentRpt 25 0.35 Exhaust No n/a No Yes 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Aralia Court Addition Calculation Date/Time:2023-08-01T13:44:50-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Aralia Court Addition (1382).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-08-01   13:45:19 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Timothy Carstairs Carstairs Energy Inc. 2238 Bayview Heights Drive, Suite E Los Osos, CA 93402 2023-08-18 14:07:15 r160610042 805-904-9048 Jim Dummit Jim Dummit 3100 Johnson Ave San Luis Obispo, CA 93401 2023-08-18 14:17:23 na 805-541-3226 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 223-P010103826A-000-000-0000000-0000 2023-08-18 14:17:23 CalCERTS inc. OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 Title 24A0.2 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 §110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour );and pool and spa heaters. * §150.0(h)1: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. §150.0(h)3A:Clearances.Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. §150.0(h)3B:Liquid Line Drier.Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer’s instructions. §150.0(j)1: Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in § 609.11 of the California Plumbing Code. * §150.0(j)2: Insulation Protection.Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment` maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. §150.0(n)1: Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must designate a space at least 2.5’ x 2.5’ x 7’ suitable for the future installation of a heat pump water heater, and meet electrical and plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no more than 2” higher than the base of the water heater §150.0(n)3: Solar Water-heating Systems.Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing(IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts and Fans: §110.8(d)3: Ducts.Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC).If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. §150.0(m)1: CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 andANSI/SMACNA-006-2006 HVAC DuctConstruction Standards MetalandFlexible3rd Edition.Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼”, If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Buildingcavities and support platforms may contain ducts; ductsinstalledin these spaces must not becompressed.* §150.0(m)2: Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3:Field-Fabricated Duct Systems.Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction. §150.0(m)7:BackdraftDamper.Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. §150.0(m)8:Gravity Ventilation Dampers.Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. §150.0(m)9: Protection of Insulation.Insulation must be protected from damage due tosunlight, moisture,equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating. §150.0(m)10:Porous Inner Core Flex Duct.Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. §150.0(m)11: Duct System Sealing and Leakage Test.When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. §150.0(m)12: Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter. * RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type o Single Family o Addition Alone Date o Multi Family o Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Aralia Court Addition 1382 Aralia Court San Luis Obispo Wood Framed 8/18/2023 CA Climate Zone 05 395 1 Wood Framed Attic Wall Wall Roof Slab Demising Wall Wood Framed Wood Framed Unheated Slab-on-Grade Wood Framed 70 49 395 395 200 40 - no insulation - R 15 R 15 R 30 R 15 R 15 New New New New New New Perim = 98' 395 Rear (NE) Right (SE) Left (NW) Left (N) Rear (E) 28.7 32.0 32.1 10.5 21.0 0.300 0.300 0.300 0.300 0.300 0.35 0.35 0.35 0.35 0.35 none none none none none none none none none none N/A N/A N/A N/A N/A New New New New New 14.0 SEER1 1 No Heating Provided Electric Heat Pump Split Air Conditioner Split Heat Pump n/a 8.80 HSPF Existing New15.0 SEER Setback Setback AtticHVAC System (Main) HVAC System (ADU) Ducted Ductless Ducted Ductless / with Fan Altered Newn/a 6.0 n/a Standard1Small Instantaneous Gas 0.930 New ID: 23-080121 Page 15 of 23EnergyPro 9.2 by EnergySoft User Number: 6249 Wood FramedWall Wall Wood Framed 136 184 R 15 R 15 New New 124 31.5 %0.30 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type o Single Family o Addition Alone Date o Multi Family o Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Aralia Court Addition 1382 Aralia Court San Luis Obispo 8/18/2023 CA Climate Zone 05 395 1 Wood Framed Wall Wall Wall Wood Framed Wood Framed 150 30 19 R 15 R 15 R 15 New New New 395 ID: 23-080121 Page 16 of 23EnergyPro 9.2 by EnergySoft User Number: 6249 124 31.5 %0.30 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Building Envelope: § 110.6(a)1:Air Leakage.Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. * §110.6(a)5:Labeling.Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). § 110.6(b):Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC)values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. * § 110.7:Air Leakage.All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, gasketed, or weather stripped. § 110.8(a):Insulation Certification by Manufacturers.Insulation must be certified by the Department of Consumer Affairs,Bureau of Household Goods and Services (BHGS). §110.8(g):Insulation Requirements for Heated Slab Floors.Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i):Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R. § 110.8(j):RadiantBarrier. When required, radiantbarriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. § 150.0(a): Roof Deck, Ceiling and Rafter Roof Insulation.Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. * §150.0(b):Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value. § 150.0(c): Wall Insulation.Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B. * § 150.0(d):Raised-floorInsulation.Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. * § 150.0(f): Slab Edge Insulation.Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(g)1:Vapor Retarder.In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to §150.0(d). § 150.0(g)2:Vapor Retarder.In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. § 150.0(q):Fenestration Products.Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. * Fireplaces, Decorative Gas Appliances, and Gas Log: §110.5(e)PilotLight.Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. §150.0(e)1:ClosableDoors.Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2:Combustion Intake.Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device. * § 150.0(e)3:FlueDamper.Masonry or factory-built fireplaces must have a flue damper withareadilyaccessiblecontrol.* Space Conditioning, Water Heating, and Plumbing System: § 110.0-§ 110.3:Certification.Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the California Energy Commission. * §110.2(a):HVACEfficiency.Equipment must meet the applicable efficiency requirements in Table 110.2-Athrough Table 110.2-N. * § 110.2(b): Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. * § 110.2(c):Thermostats.All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. * §110.3(c)3: Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank surface heat loss rating. § 110.3(c)6:Isolation Valves.Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 §150.0(m)13: Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must EH•&)0SHU ton of nominal cooling capacity, and an air-handling unit fan efficacy ”0.45 watts per CFM for gas furnace air handlers and ”0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow •250 CFM per ton of nominal cooling capacity, and an air-KDQGOLQJXQLWIDQHIILFDF\”ZDWWVSHU&)0)LHOGYHULILFDWLRQWHVWLQJLVUHTXLUHGLQDFFRUGDQFHZLWK Reference Residential Appendix RA3.3. * Ventilation and Indoor Air Quality: §150.0(o)1:Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1.* §150.0(o)1B:Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with §150.0(o)1C. §150.0(o)1C: Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses .Single-family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. §150.0(o)1G:Local Mechanical Exhaust.Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per §150.0(o)1Gvi. * §150.0(o)1H&I:Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems.The airflow required per § 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by §150.0(o)1C. §150.0(o)2: Field Verification and Diagnostic Testing.Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1G Pool and Spa Systems and Equipment: §110.4(a): Certification byManufacturers.Anypool orspa heatingsystem orequipmentmustbe certified to haveall ofthefollowing: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistanceheating. * §110.4(b)1:Piping.Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. §110.4(b)2:Covers.Outdoor pools or spas that have a heat pump or gas heater must have a cover. §110.4(b)3:Directional Inlets and Time Switches for Pools.Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §110.5:PilotLight.Natural gas pool and spa heaters must not have a continuously burning pilot light. §150.0(p):Pool Systems and Equipment Installation.Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * Lighting: §110.9: Lighting Controls and Components.All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.* §150.0(k)1A:LuminaireEfficacy.Allinstalled luminaires must meet the requirementsin Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen closets with an efficacy of at least 45 lumens per watt. §150.0(k)1B:Screwbased luminaires.Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * §150.0(k)1C:Recessed Downlight Luminaires in Ceilings.Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. §150.0(k)1D:Light Sources in Enclosed or Recessed Luminaires.Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. §150.0(k)1E:Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. §150.0(k)1F:Lighting Integral to Exhaust Fans.Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 §150.0(k)1G:Screwbased luminaires.Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * §150.0(k)1H: Light Sources in Enclosed or Recessed Luminaires.Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. §150.0(k)1I:Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. §150.0(k)2A:InteriorSwitches and Controls.All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. §150.0(k)2B:InteriorSwitches and Controls.Exhaust fans must be controlled separately from lighting systems.* §150.0(k)2A:Accessible Controls.Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned on and off. * §150.0(k)2B:Multiple Controls.Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed to comply with § 150.0(k). §150.0(k)2C:Mandatory Requirements.Lighting controls must comply with the applicable requirements of§110.9. §150.0(k)2D: Energy Management Control Systems.An energy management control system (EMCS) may be used to comply with dimming, occupancy, and control requirements if it provides the functionality of the specified control per § 110.9 and the physical controls specified in § 150.0(k)2A. §150.0(k)2E: Automatic Shutoff Controls.In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with opaque fronts or doors must have controls that turn the light off when the drawer or door is closed. §150.0(k)2F:Dimmers.Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall- mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LEDlight sources in these spaces must comply with NEMA SSL 7A. §150.0(k)2K:Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or shelves, lighting in display cabinets, and switched outletsmust be controlled separately from ceiling-installed lighting. §150.0(k)3A: Residential Outdoor Lighting.For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic time switch control) or an astronomical time clock. An energy management control system that provides the specified control functionality and meets all applicable requirements may be used to meet these requirements. §150.0(k)4:Internallyilluminated address signs.Internally illuminated address signs must either comply with § 140.8 or consume no more than 5 watts of power. §150.0(k)5:ResidentialGarages for Eight or More Vehicles.Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Solar Readiness: §110.10(a)1: Single-family Residences.Single-family residences located in subdivisions with 10 or more single-family residences and where the application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b)-(e). §110.10(b)1A: Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet.* §110.10(b)2:Azimuth.All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north. §110.10(b)3A:Shading.The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment. * §110.10(b)3B: Shading.Any obstructionlocated on the roof or any other part of the building that projects above a solar zone must be located at least twice the horizontal distance of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane.* §110.10(b)4:StructuralDesign Loads on Construction Documents.For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. §110.10(c): Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family residencesand central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system. §110.10(d):Documentation.Acopy of the construction documents or a comparable document indicating the information from § 110.10(b)-(c) must be provided to the occupant. §110.10(e)1:Main Electrical Service Panel.The mainelectrical service panel must havea minimum busbar rating of 200 amps. §110.10(e)2:Main Electrical Service Panel.The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric.” Electric and Energy Storage Ready: 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(s) Energy Storage System (ESS) Ready. All single-family residences must meet all of the following:Either ESS-ready interconnection equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, or a dedicated raceway from the main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of 225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3’ of the main panelboard, with raceways installed between the panelboard and the switch location to allow the connection of backup power source. § 150.0(t) Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the furnace with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(u) Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(v) Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the dryer location with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” *Exceptions may apply. OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 Title 24 Mandatory MeasuresA0.3 OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 SITE PLAN / REATINING WALL PLANA0.410'-0"PUE267.4'255.94.3% slope256.2258.47258.72259.5 258.8258.3257.74256.15.7% slopeFF= 259.8 GF= 259.3 Pad= 259.0 Proposed ADU 3 8 .4 7 'N ew R etaining W allsExisting Residence Note: A 2% slope shall be maintained for a min. of 3' from the ADU Addition CWCWC W C W C W C W C W C W CWCWCWCWCWCWCWCWGAS GASGASGASGASGASGASGASPGE Meter (Underground) 1" Gas Meter (Underground) Sewer Cleanout 4" SDR-35 Lateral (E) Sewer Cleanout New 4" PVC Sewer Line, slope 2% 1" Water Service 1" Water Meter on 1" service lateral Sewer Water7' C onc. B lo ck W all/Fe n ce5' Wood Fence 5' Wood Fence Dr ai nageDrainageMonument10'-0"(E) CurbN31º52'34" E(R) 138.94'N4 º 0 7 ' 3 0 " W 1 0 0 . 5 6 'N67º52'30" E (R) 109.51'L27.64' R44' A ralia C t.T A N K FA R M R O A D 5' Wood Fence Site Plan Sc: 1" = 10'-0" Top of curb FF= 259.8 GF= 259.3 Pad= 259.0 Proposed ADU 6'-0"TREE ESMT.2 3 4 5 6 7 8 9 10 11 12 s 5'-0" 1 0 '- 1 0 " 4” PVC-C900 6” PVC 1 2 3 4 5 6 7 8 9 10 11 12 s Arbutus Unedo Jiant Bird of Paradise Pepper Tree Jiant Bird of Paradise Jiant Bird of Paradise Dracena Queen Palm Dracena Queen Palm Plumb Tree Plumb Tree Plumb Tree Shrub - Myaporum Existing Trees larger than 3"Ø.... PROTECTED Tree Legend 15'-10" 1'-2" 9'-11"4'-9"5'-0"8'-0"13'-0"3'-6"4'-0"9'-6"2'-0" 5'-0" 5'-0" 8'-0"3'-6"3'-6" 4 '-6 "26'-0"2 0'-7 "1 0 '- 0 " 1 0 '- 0 " 8 '- 6 " 7 '- 4 " TW= 14'-2" 7'-4"8'-6"1'-10"5'-0"NG. = 3'-7" NG. = 7'-2" TW= 5'-0"3:1 slope Existing Conc. Block Wall Existing Allan Block Wall Existing Allan Block Wall Section 1 Sc: 1/4" = 1'-0" Existing Conc. Flatwork NG. = 0' 3:1 slope TW= 22" TW= 14'-2" Tank Farm Rd. sidewalk Compaacted Earth (assumed} Existing Conc. Flatwork & New Pavers NG. = 0' New Conc. Pavers Flatwork Landscape T erraceSlope 1:3New Alan Block retaining wall Landscape Retaining Wall Plan Sc: 1/4" = 1'-0" Existing Allan Block Retaining Wall TW= 5'-0" Existing Allan Block Retaining Wall TW= 22" New Allan Block retaining wall Existing Allan Block Retaining Wall TW= 22" Existing Conc Block Retaining Wall TW= 14' - 2"" Existing Allan Block Retaining Wall TW= 22" Existing Allan Block Retaining Wall TW= 5'-0"Property LineP rop e rty Lin e P r o pe r t y L i n e TW= 5'-0" TW= 5'-0" New Allan Block retaining wall 2 '- 6 " T W = 6 '-0 "TW= 22" C u t A rea = 26 cu. Y d s.(H atched )Existing Allan Block Retaining Wall to Omit TW= 22" Existing Allan Block Retaining Wall to Omit TW= 22" S e c .AS e c . B S e c . 1 Landscape T erraceSlope 1:3Landscape T erraceSlope 1:3(E) Fence Line FF= 259.8 GF= 259.3 Pad= 259.0 Proposed ADU FF= 259.8 GF= 259.3 Pad= 259.0 Existing ResidenceSec.B    '(7$,/127(6      3$9(563(5$5&+ /'5$:,1*6 &21&:$// #,2&9(57 #,2&+25,=   ‘3(5)3,3( &$17  &/5 6/23(72287/(7'5$,1 :$7(53522),1* , ,$66+2:1 ),/7(552&.3(5$//$1%/2&.    0$;         5(7$,1,1*:$//'(7$,/$    0$;     )25723 #2&9(57,&$/ 7<3,&$/ &203$&7('62,/ 6&$/(   )25%27720  &/5&/5&/5    '(7$,/127(6     $//$1%/2&. 3$9(563(5$5&+ /'5$:,1*6 &21&:$// 6+2:1 #2&  $//$1%/2&.:$// 237,21$/ ‘3(5)3,3( &$17  &/5 6/23(72287/(7'5$,1 :$7(53522),1* , ,5(3/$&((;,67,1*:,7+ ),/7(552&.3(5$//$1%/2&. 6$1'<%$&.),//    0$;  0$;  ,ƒ     ,172$//$1%/2&.  9(1((5720$7&+(;,67,1*$//$1%/2&.        5(7$,1,1*:$//:$//$1%/2&.'(7$,/%6&$/(    &/5&/5&/5(E) SHRUB (E) SHRUB FG:259.0' FG:259.0' GRADING NOTE: EARTH ADJACENT TO FOUNDATION SHALL BE MIN 8" BELOW FINISHED FLOOR OR UNTREATED WOOD. IMPROVED SURFACE TO BE 2" BELOW WEEP SCREED. MINIMUM SLOPE AWAY FROM FOUNDATION TO BE 5% FOR DIRT, AND 2% FOR IMPROVED SURFACE. LANDING F.S. 259.60' LANDING F.S. 259.60' 1 ADDED SHEET ADDRESS NOTE PROVIDE ADDRESS TO BE VISIBLE FROM THE RIGHT OF WAY 1 2 2 2 OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 Erosion Control MeasuresA0.5 SILT FENCING CASQA DETAIL SE-1 1 FIBER ROLLS CASQA DETAIL SE-5 2CONCRETE WASTE MANAGEMENT CASQA DETAIL WM-8 4 STORN DRAIN INLET PROTECTION CASQA DETAIL SE-10 3 Wind Erosion Control WE-1 May 2011 California Stormwater BMP Handbook 1 of 5 Construction www.casqa.org Description and Purpose Wind erosion or dust control consists of applying water or other chemical dust suppressants as necessary to prevent or alleviate dust nuisance generated by construction activities. Covering small stockpiles or areas is an alternative to applying water or other dust palliatives. California’s Mediterranean climate, with a short “wet” season and a typically long, hot “dry” season, allows the soils to thoroughly dry out. During the dry season, construction activities are at their peak, and disturbed and exposed areas are increasingly subject to wind erosion, sediment tracking and dust generated by construction equipment. Site conditions and climate can make dust control more of an erosion problem than water based erosion. Additionally, many local agencies, including Air Quality Management Districts, require dust control and/or dust control permits in order to comply with local nuisance laws, opacity laws (visibility impairment) and the requirements of the Clean Air Act. Wind erosion control is required to be implemented at all construction sites greater than 1 acre by the General Permit. Suitable Applications Most BMPs that provide protection against water-based erosion will also protect against wind-based erosion and dust control requirements required by other agencies will generally meet wind erosion control requirements for water quality protection. Wind erosion control BMPs are suitable during the following construction activities: Categories EC Erosion Control SE Sediment Control : TC Tracking Control WE Wind Erosion Control ; NS Non-Stormwater Management Control WM Waste Management and Materials Pollution Control Legend: ; Primary Category : Secondary Category Targeted Constituents Sediment ; Nutrients Trash Metals Bacteria Oil and Grease Organics Potential Alternatives EC-5 Soil Binders If User/Subscriber modifies this fact sheet in any way, the CASQA name/logo and footer below must be removed from each page and not appear on the modified version. Wind Erosion Control WE-1 May 2011 California Stormwater BMP Handbook 2 of 5 Construction www.casqa.org „ Construction vehicle traffic on unpaved roads „ Drilling and blasting activities „ Soils and debris storage piles „ Batch drop from front-end loaders „ Areas with unstabilized soil „ Final grading/site stabilization Limitations „ Watering prevents dust only for a short period (generally less than a few hours) and should be applied daily (or more often) to be effective. „ Over watering may cause erosion and track-out. „ Oil or oil-treated subgrade should not be used for dust control because the oil may migrate into drainageways and/or seep into the soil. „ Chemical dust suppression agents may have potential environmental impacts. Selected chemical dust control agents should be environmentally benign. „ Effectiveness of controls depends on soil, temperature, humidity, wind velocity and traffic. „ Chemical dust suppression agents should not be used within 100 feet of wetlands or water bodies. „ Chemically treated subgrades may make the soil water repellant, interfering with long-term infiltration and the vegetation/re-vegetation of the site. Some chemical dust suppressants may be subject to freezing and may contain solvents and should be handled properly. „ In compacted areas, watering and other liquid dust control measures may wash sediment or other constituents into the drainage system. „ If the soil surface has minimal natural moisture, the affected area may need to be pre-wetted so that chemical dust control agents can uniformly penetrate the soil surface. Implementation Dust Control Practices Dust control BMPs generally stabilize exposed surfaces and minimize activities that suspend or track dust particles. The following table presents dust control practices that can be applied to varying site conditions that could potentially cause dust. For heavily traveled and disturbed areas, wet suppression (watering), chemical dust suppression, gravel asphalt surfacing, temporary gravel construction entrances, equipment wash-out areas, and haul truck covers can be employed as dust control applications. Permanent or temporary vegetation and mulching can be employed for areas of occasional or no construction traffic. Preventive measures include minimizing surface areas to be disturbed, limiting onsite vehicle traffic to 15 mph or less, and controlling the number and activity of vehicles on a site at any given time. Wind Erosion Control WE-1 May 2011 California Stormwater BMP Handbook 3 of 5 Construction www.casqa.org Chemical dust suppressants include: mulch and fiber based dust palliatives (e.g. paper mulch with gypsum binder), salts and brines (e.g. calcium chloride, magnesium chloride), non- petroleum based organics (e.g. vegetable oil, lignosulfonate), petroleum based organics (e.g. asphalt emulsion, dust oils, petroleum resins), synthetic polymers (e.g. polyvinyl acetate, vinyls, acrylic), clay additives (e.g. bentonite, montimorillonite) and electrochemical products (e.g. enzymes, ionic products). Site Condition Dust Control Practices Permanent Vegetation Mulching Wet Suppression (Watering) Chemical Dust Suppression Gravel or Asphalt Temporary Gravel Construction Entrances/Equipment Wash Down Synthetic Covers Minimize Extent of Disturbed Area Disturbed Areas not Subject to Traffic X X X X X X Disturbed Areas Subject to Traffic X X X X X Material Stockpiles X X X X X Demolition X X X Clearing/ Excavation X X X Truck Traffic on Unpaved Roads X X X X X Tracking X X Additional preventive measures include: „ Schedule construction activities to minimize exposed area (see EC-1, Scheduling). „ Quickly treat exposed soils using water, mulching, chemical dust suppressants, or stone/gravel layering. „ Identify and stabilize key access points prior to commencement of construction. „ Minimize the impact of dust by anticipating the direction of prevailing winds. „ Restrict construction traffic to stabilized roadways within the project site, as practicable. „ Water should be applied by means of pressure-type distributors or pipelines equipped with a spray system or hoses and nozzles that will ensure even distribution. „ All distribution equipment should be equipped with a positive means of shutoff. „ Unless water is applied by means of pipelines, at least one mobile unit should be available at all times to apply water or dust palliative to the project. „ If reclaimed waste water is used, the sources and discharge must meet California Department of Health Services water reclamation criteria and the Regional Water Quality Wind Erosion Control WE-1 May 2011 California Stormwater BMP Handbook 4 of 5 Construction www.casqa.org Control Board (RWQCB) requirements. Non-potable water should not be conveyed in tanks or drain pipes that will be used to convey potable water and there should be no connection between potable and non-potable supplies. Non-potable tanks, pipes, and other conveyances should be marked, “NON-POTABLE WATER - DO NOT DRINK.” „ Pave or chemically stabilize access points where unpaved traffic surfaces adjoin paved roads. „ Provide covers for haul trucks transporting materials that contribute to dust. „ Provide for rapid clean up of sediments deposited on paved roads. Furnish stabilized construction road entrances and wheel wash areas. „ Stabilize inactive areas of construction sites using temporary vegetation or chemical stabilization methods. For chemical stabilization, there are many products available for chemically stabilizing gravel roadways and stockpiles. If chemical stabilization is used, the chemicals should not create any adverse effects on stormwater, plant life, or groundwater and should meet all applicable regulatory requirements. Costs Installation costs for water and chemical dust suppression vary based on the method used and the length of effectiveness. Annual costs may be high since some of these measures are effective for only a few hours to a few days. Inspection and Maintenance „ Inspect and verify that activity-based BMPs are in place prior to the commencement of associated activities. „ BMPs must be inspected in accordance with General Permit requirements for the associated project type and risk level. It is recommended that at a minimum, BMPs be inspected weekly, prior to forecasted rain events, daily during extended rain events, and after the conclusion of rain events. „ Check areas protected to ensure coverage. „ Most water-based dust control measures require frequent application, often daily or even multiple times per day. Obtain vendor or independent information on longevity of chemical dust suppressants. References Best Management Practices and Erosion Control Manual for Construction Sites, Flood Control District of Maricopa County, Arizona, September 1992. California Air Pollution Control Laws, California Air Resources Board, updated annually. Construction Manual, Chapter 4, Section 10, “Dust Control”; Section 17, “Watering”; and Section 18, “Dust Palliative”, California Department of Transportation (Caltrans), July 2001. Wind Erosion Control WE-1 May 2011 California Stormwater BMP Handbook 5 of 5 Construction www.casqa.org Prospects for Attaining the State Ambient Air Quality Standards for Suspended Particulate Matter (PM10), Visibility Reducing Particles, Sulfates, Lead, and Hydrogen Sulfide, California Air Resources Board, April 1991. Stormwater Quality Handbooks Construction Site Best Management Practices (BMPs) Manual, State of California Department of Transportation (Caltrans), March 2003. 15'-10" 1'-2" 9'-11"4'-9"5'-0"8'-0"13'-0"3'-6"4'-0"9'-6"2'-0" 5'-0" 5'-0"(E) C onc. 5' B lk. W allProperty Lin e(E) 3' C onc. B lk. R etainin g W all( E ) 2 ' Co nc . Bl k . Ret a i ni n g Wa l l(N ) 2' C o n c. B lk. R e tain in g W all(N) 16" Conc. Blk. Retaining Wall (N) 5' Retaining Wall omit (E) 3' Conc. Blk. Retaining Wall Setback Setback omit (E) 3' Conc. Blk. Retaining Wall 5 '-0"Se tb ack(E) Land scap e T e rrace(E) Land scape T e rrace( E ) L a n d s c a p e Te r r a c e (N) Floor match (E) conc. slab floor (E) conc. slab floor (E) Residence (no work this area) (E) Kitchen (no work this area) (E) Residence (no work this area) (N) conc. Pavers (N) conc. Pavers (E) edge of old flatwork (omitted) P rop erty Line 38'Property Line 139'Minisplit Headminisplit Heat Pump (E) conc. flatwork (E) sewer cleanout (N) 16" conc. blk. planter (N) 16" conc. blk. planter 8'-0"3'-6"3'-6" 4 '-6 "(E) conc. flatwork (N) conc. Pavers On Demand W.Htr. 10'-10" omit (E) Perimiter Wall Replace w/ (N) exposed Roof Bm. (N) 13" x 13" Decorative Box.Bm. 8' Flr.to bottom match existing (E) 13"x13" Decorative Box Bm. (N) Dining Rm.Addition Conc. FLoor 6'-10"(N) 2x6 Wall (N) 2x6 Wall(E) Dining Rm. (N) exposed Ridge Bm. (E) Res. Wall (E) Residence (no work this area) (E) Residence (no work this area)Floor Plan Sc: 1/4" = 1'-0" 3 Sht-A3 3 Sht-A3 1 Sht-A3 1 Sht-A3 2 Sht-A3 2 Sht-A326'-0"P r o pe r t y L i n e 1 1 0 '20 '-7"1 0 '- 0 " (N) 6x Hdr. (E) Res. Wall 3 Sht-A3 1 Sht-A3 1 Sht-A3 2 Sht-A3 2 Sht-A3 3 Sht-A3 DOOR SCHEDULE: Project: Stenger Res.hh Manufacturer: Header Sidelight Door #Location Type Height Swing Thickness width width Notes D1 Entry Swing Simple 6'-8"LH 1 3/4"3'-6"Wood Panel Door, Dual Glazed -Ripple Glass D2 Living Slider 6'-8"LH 1 3/8 2'-8"Milgard Vinyl D3 Bath Swing Simple 6'-8"LH 1 3/8 6'-0"Wood Panel D4 Bed Rm.Pocket 6'-8"1 3/8 2'-8"Wood Panel D5 Dining Rm.Swing Bi-Part.6'-8"Out 1 3/8 2'-8"16"Milgard Vinyl, Dual Glazed W1 W2 W3 W4 W5 W6 WINDOW SCHEDULE: Project:Stenger Res. Manufacturer: Milgard or similar 1ST FLOOR Header Window Window Door #Location Type Height Width Height Notes W1 Kitchen Horiz.Slider 6'-8"3'-0"3'-6"Vinyl - Dual Glazed W2 Kitchen Horiz.Slider 6'-8"3'-0"3'-6"Vinyl - Dual Glazed W3 Kitchen Horiz.Slider 6'-8"3'-0"3'-6"Vinyl - Dual Glazed W4 Bath Horiz.Slider 6'-8"2'-6"3'-6"Vinyl - Dual Glazed W5 Dining Room Fixed 6'-8"2'-0"5'-0"Vinyl - Dual Glazed - Match Existing Windows W6 Dining Room Fixed 9'-6"2'-0"2'-0"Vinyl - Dual Glazed - Match Existing Windows W7 Dining Room Fixed 7'-8"8'-0"1'-4"Vinyl - Dual Glazed - 7 Panels W7 Upper Lower D1 D2 D3 D4 D5(N ) 5' R etainin g W all(E) SHRUB (E) SHRUB 1 2 34 5 6 7 8 ONE HOUR WALL ONE HOUR DOOR1 FLOOR PLAN REFERENCE NOTES: SOLID SURFACE COUNTERTOP, VERIFY STYLE, COLOR, MANUF. WITH OWNER1 PROVIDE 36" REFRIGERATOR SPACE AND ROUGH PLUMB FOR ICE MAKER IN RECESSED WALL BOX2 DOUBLE KITCHEN SINK W/ GARBAGE DISPOSAL, PROVIDE SWITCH3 30" ELECT. RANGE/OVEN (VERIFY DIMENSIONS W/ MANUFACTURER) W/ HOOD ABOVE, MIN 100 CFM EXHAUST TO EXTERIOR4 BUILT-IN DISHWASHER, GFCI CURCUIT. VERIFY DIMENSIONS WITH MANUFACTURER5 LINE OF CABINETS ABOVE6 7 8 LOW FLOW LAVATORY FAUCET AND SINK LOW FLOW TOILET OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 Floor PlanA1Existing Floor Plan Sc: 1/4"= 1'-0" (N) ADU Bedroom (E) Dining Room WALL LEGEND: NEW 2X6 WALL EXISTING 2X6 WALL (E) Kitchen SHT. # #DETAIL NUMBER SHEET NUMBER B A-8.0 DESIGNATES THE ELEVATION (INTERIOR OR EXTERIOR) OR SECTION SHEET NUMBER TEMP GLZ = SAFETY GLAZING, REFER TO NOTE, T-1.1 INSULATION: EXTERIOR 2X6 WALLS SHALL BE R-21. ROOF INSULATION SHALL BE R-30 MIN - CLOSED CELL SPRAY FOAM, WITH MIN 5.5 R PER INCH. DIMENSIONAL PLAN GENERAL NOTES: 1.ALL INTERIOR DOOR HEIGHTS SHALL BE 8'-0" U.N.O. VERIFY ROUGH OPENINGS PRIOR TO FRAMING 3.ALL ANGLES ARE AT 45°, U.N.O. 4. 5.SET BUILDING FOOTPRINT 3" MIN. AWAY FROM THE BUILDING SETBACK LINES TO ALLOW FOR FINISH MATERIALS 2.ALL EXTERIOR DOOR AND WINDOW HEIGHTS SHALL BE 8'0" U.N.O. VERIFY ROUGH OPENINGS PRIOR TO FRAMING 6. 7.PROVIDE BLOCKING @ ALL BUILT-INS AND MIRRORS 8. DIMENSIONAL PLAN GENERAL NOTES: 1. 3.ALL ANGLES ARE AT 45°, U.N.O. 4.VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT WITH ALL DISCREPANCIES PRIOR TO CONSTRUCTION 5. 2. 6.ALL FINISH CEILING HEIGHTS SHALL BE +10'-0" TYP. U.N.O.- REFER TO FLOOR PLANS 7. 8.NOTE: TEMP. = TEMPERED GLAZING. REFER TO SHEET A-3.0 FOR ADDITIONAL INFORMATION. FLOOR PLAN GENERAL NOTES: 1.VERIFY ALL APPLIANCE, FIXTURE & EQUIPMENT SIZES AND LOCATIONS W/ OWNER, PRIOR TO INSTALLATION 2.VERIFY ALL APPLIANCE REQUIRED TEMPERED GLAZING PER SPECIFICATION SHEET T-1.1 AND PER LOCAL JURISDICTION. 3.PROVIDE BUILT-IN SHOP FABRICATION PLANS AND ELEVATIONS FOR APPROVAL PRIOR TO FABRICATION. VERIFY ALL LOCATIONS, SIZES AND CONFIGURATIONS W/ OWNER PRIOR TO FABRICATION. 4.SHOWER AREA WALLS SHALL BE FINISHED WITH A SMOOTH NONABSORBENT SURFACE TO A HEIGHT OF 70" ABOVE DRAIN INLET. 5.SUFFICIENT WOOD BLOCKING SHALL BE PROVIDED @ ALL STUDS FOR SECURING ALL ITEMS INCLUDING BUT NOT LIMITED TO COUNTERS, SHELVING, CASEWORK AND FURNITURE. 6.PRIME ALL SIDES OF EXTERIOR TRIM PRIOR TO INSTALLATION. OMIT FIREPLACE SEE SPEC SHIT SHEET 1 1 The ADU must comply with the Aging-in Place Design 1.R327.1.1: REINFORCEMENT FOR GRAB BARS- AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH SECTION R327. 2.R327.1.2: ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS- ALL CONTROLS INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48” MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. 3.R327.1.4: DOORBELL BUTTONS OR CONTROLS, SHALL NOT EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. 1 (N) AADU (E) Residence (N) Dining Addition (E) Residence (E) Residence (N) ADU 13'-0"(E) Residence East Elevation Sc: 1/4" = 1'-0"North Elevation Sc: 1/4" = 1'-0"13'-0"9'-0"8'-0"(N) ADU(N) Dining Additionh West Elevation Sc: 1/4" = 1'-0"13'-0"(N) ADU (E) Residence OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 ElevationsA2 North Rast View Dining Room Addition (N) ADU Stucco Exterior Throughout Match (E) Stucco Color Dining Room Scale: 1/4" = 1'-0"39'-0"Dining Rm. Addition (E) Dining Rm. (E) Living Rm. 12 5 12 5 (N) 6x Roof Bm. (N) Decorative Box Bm.(N) Decorative Box Bm. (N) Decorative Col. (N) Windows (N) Door (N) Hdr. & Door (E) Decorative Box Bm. & col. (N) wall ADU - Existing Residence Scale: 1/4" = 1'-0"18'-0"13'-0"9'-0"Plt. HeightKitchen Plt. Height (E) Bedroom for (N) ADU (E) Residence (E) Residence (E) Roof (E) Roof (E) Roof (E) Walls (N) 2"x8" Rafters @ 16" o.c. cut slope 1/4"h/12" slope (N) ADU Addition provide 1 layer of 5/8" Type X Gypsum wallboard (N) 2"x8" Rafters @ 16" o.c. ADU Scale: 1/4" = 1'-0"28'-0"8'-0"9'-0"Bathroom Kitchen Plt. Ht.Plt. Ht. Plt. Ht.13'-0"12 5 (N) ADU Addition OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 SectionsA3 Framing & Insulation Notes: 1- Perimeter walls 2x6 @ 16" o.c. 2- Roof Assemblt Notes: Roof 2x8 rafters @ 16" o.c. Provide closed cell @eave blocking filled with Polyurethane with min. R value of 6/inch 2x8 rafter = (7.25" x 6) = 43.5 R valud 3- 1/2" Drywall walls and vaulted ceiling ' throughout FIRE BLOCK NOTE FIRE BLOCK STUD WALLS (AT 10FT. INTERVALS [HORIZONTAL & VERTICAL]), ENCLOSED AND CONCEALED SPACES, AND AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, BETWEEN ATTIC AND CHIMNEY CHASE, AT STAIR STRINGERS, AND SIMILIAR PLACES AT CEILING AND FLOOR LEVELS. INSULATION NOTE COMPLETLY ENCLOSE RAFTER SPACE WITH CLOSED CELL SPRAY INSULATION WITH R=6 PER INCH. FRAMING IS 2X8 = 7.25 INCH X 6 = R 43.5 ASSEMBLY. 1 WINDOW PER PLAN2 DOOR PER PLAN3 4 EXTERIOR PLASTER, TO MATCH EXISTING, VERIFY WITH OWNER COMPOSITION ROOFING PER ROOF PLAN, MATCH EXISTING ROOF STRUCTURE PER STRUCTURAL PLANS5 LINE OF SHELVING, VERIFY WITH OWNER6 7 NEW S.O.G. FLOOR, SEE STRUCTURAL DRAWINGS8 NEW FOUNDATION PER STUCTURAL PLAN INSULATION, NON VENTED, CLOSED CELL FOAM PER NOTE THIS SHEET9 OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 (E) SHRUB (E) SHRUB Roof Plan Scale: 1/4" = 1'-0"48'Plt. Ht.5:12 slope(E) Roof (E) Roof (E) Roof2 Story(E) Ridge Bm. (N) Roof Bm. 5:12 slope (N) Roof vaulted ceiling +/- 9'4" 'Plt. Ht. 5:12 slope (N) Roof match (E) Roof (E) Roof vaulted ceiling (E) Roof vaulted ceiling (N) Roof 9'Plt. Ht. 1/4:12 slope 6x HDR.9'Plt. Ht.5:12 slope(N) Roof 8'Plt. Ht.1/4:12 slope(N) Roof(N) Ridge Bm.(N) Roof A4Roof PlanGENERAL ROOF NOTES: 1. 2. 3. 4. 5. 6. ROOFING MATERIALS AND INSTALLATION SHALL BE IN ACCORDANCE WITH CHAPTER 15, 2019 C.B.C. A. B. UNDERLAYMENT ROOFING: ROOF SLOPE: TYPE: REFER TO ROOF NOTE THIS SHEET TYPE: REFER TO NOTE THIS SHEET SLOPE: 5:12C. FLASH CRICKETS AND VALLEYS IN ACCORDANCE WITH 2019 C.B.C. SECTION 1507. FLASH AND COUNTERFLASH JUNCTIONS OF ROOFS AND VERTICAL SURFACES PER ROOFING MANUFACTURER'S RECOMMENDATIONS AND, WHEN OF METAL, SHALL NOT BE LESS THAN 26 GAGE CORROSION-RESISTANT METAL FLASH ALL PLUMBING, MECHANICAL, AND ELECTRICAL ROOF PENETRATIONS. ALL WEATHER EXPOSED SURFACES SHALL HAVE A WEATHER-RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING AND THAT EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF. ALL FLASHING AT VALLEYS SHALL BE 28 GAGE MIN. CORROSION-RESISTANT METAL 7. Gutter = Down Spout = ROOFING: 1- Manufacturer is US Tile by Boral (or similar ) 2- approved number: 1-Piece “S” Tile is Class 3 Hail Rated product per FM4473 standards. Select 1-Piece “S” Tile meets Grade 1 standards per ASTM C1167. - COLOR: (VERIFY W/ OWNER- Match Existing Tile), INSTALL PER MANUFACTURERS SPECIFICATIONS. ROOF COVERING AND INSTALLATION AS PER UBC 3203, TABLE 32-D-2. ALL ROOFING SHALL COMPLY WITH SECTION 4203, PUBLIC RESOURCES CODE. ROOFING CONTRACTOR SHALL PROVIDE CERTIFICATION OF ROOF COVERING CLASSIFICATION TO THE COUNTY OF SAN LUIS OBISPO PRIOR TO FINAL INSPECTION. CLAY ROOF TILES 1203.2 ATTIC SPACES. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATION OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN AND SNOW. BLOCKING AND BRIDGING SHALL BE ARRANGED SO AS NOT TO INTERFERE WITH THE MOVEMENT OF AIR. AN AIRSPACE OF NOT LESS THAN 1 INCH SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150TH OF THE AREA OF THE SPACE VENTILATED. EXCEPTIONS: 1. THE NET FREE CROSS-VENTILATION AREA SHALL BE PERMITTED TO BE REDUCED TO 1/300 PROVIDED THAT NOT LESS THAN 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. 2. THE NET FREE CROSS-VENTILATION AREA SHALL BE PERMITTED TO BE REDUCED TO 1/300 WHERE A CLASS I OR II VAPOR BARRIER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 3. ATTIC VENTILATION SHALL NOT BE REQUIRED WHEN DETERMINED NOT NECESSARY BY THE BUILDING OFFICIAL DUE TO ATMOSPHERIC OR CLIMATIC CONDITIONS. 1203.2.1 OPENINGS INTO ATTIC. EXTERIOR OPENINGS INTO THE ATTIC SPACE OF ANY BUILDING INTENDED FOR HUMAN OCCUPANCY SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, SQUIRRELS, RODENTS, SNAKES AND OTHER SIMILAR CREATURES. OPENINGS FOR VENTILATION HAVING A LEAST DIMENSION OF NOT LESS THAN 1/16 INCH AND NOT MORE THAN 1/4 INCH SHALL BE PERMITTED. OPENINGS FOR VENTILATION HAVING A LEAST DIMENSION LARGER THAN 1/4 INCH SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF NOT LESS THAN 1/16 INCH AND NOT MORE THAN 1/4 INCH. ROOF PLAN REFERENCE NOTES METAL GUTTER, PAINT, VERIFY WITH OWNER INDICATES METAL DOWNSPOUT, PAINT, VERIFY WITH OWNER EXISTING TILE ROOFING - CLASS 'A' MINIMUM - VERIFY CONDITION IN FIELD1 2 3 4 OHAGIN ATTIC VENT PER CALC THISSHEET, REFER TO DTL 19/A-10.0 NEW TILE ROOFING TO MATCH EXISTING - CLASS 'A' MINIMUM, SEE SPECIFCATION THIS SHEET 5 1 5 2 2 3 3 GENERAL ROOF NOTES: 1. 2. 3. 4. 5. 6. 7. 8. ROOFING MATERIALS AND INSTALLATION SHALL BE IN ACCORDANCE WITH CHAPTER 15, 2019 C.B.C. A. B. UNDERLAYMENT ROOFING: ROOF SLOPE: TYPE: REFER TO ROOF NOTE THIS SHEET TYPE: REFER TO NOTE THIS SHEET SLOPE: 5:12C. FLASH CRICKETS AND VALLEYS IN ACCORDANCE WITH 2019 C.B.C. SECTION 1507. FLASH AND COUNTERFLASH JUNCTIONS OF ROOFS AND VERTICAL SURFACES PER ROOFING MANUFACTURER'S RECOMMENDATIONS AND, WHEN OF METAL, SHALL NOT BE LESS THAN 26 GAGE CORROSION-RESISTANT METAL FLASH ALL PLUMBING, MECHANICAL, AND ELECTRICAL ROOF PENETRATIONS. PROVIDE ATTIC CROSS VENTILATION PER NOTE THIS SHEET (C.B.C. SECTION 1203.2) PROTECT ATTIC VENTS AGAINST ENTRANCE OF RAIN AND SNOW. COVER ATTIC VENTS WITH CORROSIVE RESISTANT WIRE MESH. MESH OPENINGS OF 1/8" MINIMUM, 1/4" MAXIMUM. C.B.C. 1203.2.1. ALL WEATHER EXPOSED SURFACES SHALL HAVE A WEATHER-RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING AND THAT EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF. 9.ALL FLASHING AT VALLEYS SHALL BE 28 GAGE MIN. CORROSION-RESISTANT METAL LOW SLOPE ROOF UNDERLAYMENT NOTES: FOR ROOF SLOPES FROM 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12), UP TO 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), UNDERLAYMENT SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING MANNER: APPLY A 19-INCH STRIP OF UNDERLAYMENT FELT PARALLEL TO AND STARTING AT THE EAVES. STARTING AT THE EAVE, APPLY 36-INCH-WIDE SHEETS OF UNDERLAYMENT, OVERLAPPING SUCCESSIVE SHEETS19 INCHES. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL. END LAPS SHALL BE 4 INCHES AND SHALL BE OFFSET BY 6 FEET. UNVENTED ATTIC NOTES INSULATION NOTE COMPLETLY ENCLOSE RAFTER SPACE WITH CLOSED CELL SPRAY INSULATION WITH R=6 PER INCH. FRAMING IS 2X8 = 7.25 INCH X 6 = R 43.5 ASSEMBLY. 1 OF TBD SHEETS REVISIONS PROJECT:SHEET TITLE:JOB NO.: DATE: 07/25/2023 APPROVED: SHEETDRAWINGS PREPARED BY:JIM DUMMIT ENTERPRISES3100 JOHNSON AVESAN LUIS OBISPO, CA. 93401805 541-3226 805 235-5038jdent1@charter.netSingle Family Residence Remodel& New ADU1382 Aralia Ct.San Luis Obispop,California 93950APN: 053-092-009OWNER:Mary kay Stenger1382 Aralia Ct.San Luis Obispop,California 93950 Stenger 1.7 1 RESUBMITTAL 1/10/2024 2 RESUBMITTAL 2/15/2024 A5Electric Plan(E) SHRUB Elec. Plan Scale: 1/4" = 1'-0"2 220 Hi 44" 42" GFI SD SD DIMS3S 3S 3SS44"GFI SSS100 A Elec Sub Panel Refrig DW SGar.D. Elec. Stove w/ Fan220 44" Stack W/D H.B.H.B. MiniSplit Head MiniSplit On Demand W.H.TVDIMSSMiniSplit Notes: Mitsubishi Elec. Equipment (or similar) PUZ-A18nka7 Heat Pump 18,557 BTU's Cooling 18,620 BTU's Heating Garage 2. SMOKE AND CARBON MONOXIDE (CO2) DETECTORS - SMOKE AND CO2 DETECTORS SHALL BE INTEGRATED INTO ONE DEVICE - REQUIRED SMOKE AND CO2 ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. SMOKE ALARMS SHALL EMIT A SIGNAL WHEN THE BATTERIES ARE LOW. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. - SMOKE AND CO2 ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS CLOSED. - SMOKE DETECTORS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL217 AND INSTALLED IN ACCORDANCE WITH THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA72. - CO2 SINGLE AND MULTIPLE-STATION DETECTORS SHALL BE LISTED TO COMPLY WITH UL2034. CO2 DETECTORS SHALL BE LISTED TO COMPLY WITH UL2075. INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA720 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, INCLUDING DISTANCES FROM VERTICAL WALLS. (SEE A1.0 FOR NEW CO2 IN EXISTING RESIDENCE) 3. GFCI RECEPTABLE OUTLETS MUST BE INSTALLED IN A READILY-ACCESSIBLE LOCATION. 4. RECEPTACLE OUTLETS SERVING THE KITCHEN COUNTERTOPS, GARAGE, AND OUTDOORS SHALL BE GFCI PROTECTED. 5. KITCHEN OUTLET WIREMOLD SURFACE MOUNTED TO THE UNDERSIDE OF THE UPPER CABINETS SHALL NOT EXCEED 20" ABOVE THE COUNTER LEVEL. 6. EACH MULTIWIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES. CEC 210.4 (B) 7. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS AND DEVICES IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED COMBINATION-TYPE AFCI. CEC 210.12(B) AND BE TAMPER RESISTANT. 8. EXTERIOR LIGHT FIXTURES SHALL COMPLY WITH NIGHT SKY PRESERVATION. 1. BATHROOM EXHAUST FANS SHALL BE MIN. 50 CFM. ELECTRICAL NOTES: 9. AT LEAST ONE 20-AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTICAL OUTLET(S). 10. BRANCH CIRCUITS SUPPLYING GARAGE RECEPTACLE OUTLETS SHALL NOT SUPPLY OUTLETS OUTSIDE OF GARAGE 11. ALL INSTALLED LUMINAIRE SHALL BE HIGH EFFICACY IN ACCORDANCE WITH CEnC TABLE 150-A 12. RECESSED DOWNLIGHT LUMINARIES IN CEILINGS SHALL MEET ALL OF THE REQUIREMENTS LISTED IN CEnC SECTION 150.0(K)(2), 13 SCREW BASED LUMINARIES SHALL MEET ALL OF THE REQUIREMENTS LISTED IN CEnC SECTION 150.0(K)(1)(G), 14 INTERIOR LIGHTING SWITCHING DEVICES AND CONTROLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS LISTED IN CEnC SECTION 150.0(K)(2), 15 LIGHTING INSTALLED IN BATHROOMS SHALL MEET THE FOLLOWING REQUIREMENT: CENC 150.0(K)(5), ALL LIGHTING SHALL BE HIGH EFFICACY AND AT LEASE ONE LIGHT SHALL BE CONTROLLED WITH A VACANCY SENSOR 16. LIGHTING IN ATTACHED AND DETACHED GARAGES, BATHROOM, LAUNDRY ROOMS, AND UTILITY ROOMS HALL BE HIGH EFFICACY LUMINARIES AND AT LEAST ONE CIRCUIT CONTROLLED BY VACANCY SENSORS: CENC 150.0(K)(6) 17. LUMINARIES PROVIDING OUTDOOR LIGHTING, INCLUDING LIGHTING FOR PRIVATE PATIOS, ENTRANCES, BALCONIES, PORCHES, ETC., WHICH ARE PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING SHALL BE CONTROLLED BY AN ON/OFF SWITCH, WHICH DOES NOT OVERRIDE TO ON, MOTION SENSOR, PHOTOCONTROL MOTION SENSOR WITHOUT OVERRIDE PHOTOCONTROL WITHOUT OVERRIDE: CENC 150.0(K)(9) M.D. TV TELEVISION MOTION DETECTOR GFI WP GROUND FAULT INTERRUPTER WATER PROOF INTERCOM ELECTRICAL LEGEND: FL FLUORESCENT RECESSED LIGHT LED WALL WASHER3DIMSF.G. H.B. C.W. 220 GAS KEY W/LOOSE KEY HOSE BIB FUEL GAS DIMMER SWITCH 3-WAY SWITCH SINGLE SWITCH, DIMMER FLOOR OUTLET 4-PLEX OUTLET 220V OUTLET DUPLEX OUTLET HALF-HOT OUTLET COLD WATER LED RECESSED LIGHT FLUORESCENT TUBE LIGHTING SURFACE MOUNTED ABOVE CABINET LIGHT W/SWITCH DOOR CHIMES PUSH BUTTON TELEPHONE SD SMOKE DETECTOR/C.O.DETECTOR LED WALL SCONCE LED DECORATIVE PENDANT LIGHT FLUORESCENT WALL SCONCE H ENERGYSTAR BATHROOM EXHAUST FAN/IAQ FAN, WITH RATE OF 50 CFM (4.0 SOHN) FOR INTERMITTENT, OR 20 CFM FOR CONTINUOUS VENTILATION. SEE NOTE THIS SHEET. HEAT LAMP TTHERMOSTAT J J-BOX F S44-WAY SWITCHS SH.W.HOT WATER CEILING FAN LIGHTS AND FAN SHALL BE SWITCHED SEPERATLY BATHROOM FAN NOTE: FANS SHALL BE ENERGY STAR COMPLIANT AND DUCTED TO THE EXTERIOR OF THE BUILDING. UNLESS FUNCTIONING AS A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL. - HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50% TO A MAX OF 80%. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. - A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL (I.E., BUILT-IN). NOTES: 1. FOR THE PURPOSE OF THIS SECTION, A BATHROOM IS A ROOM WHICH CONTAIN A BATHTUB, SHOWER, OR BATH/SHOWER COMBINATION. 2. LIGHTING INTEGRAL TO BATHROOM EXHAUST FANS SHALL COMPLY WITH THE CALIFORNIA ENERGY CODE.SSINGLE SWITCH, VACANCY SENS.OCC HUM HUMIDISTAT CONTROLLEDS 18. ALL AREAS SPECIFIED IN 206.12. ALL 125 VOLT, 15- AD 20 AMPERE RECEPTICALS SHALL BE LISTED TAMPER RESISTANT. 19. A MINIMUM OF TWO 20-AMP SMALL APPLIANCE BRANCH CIRSHALL BE PROVIDED FOR ALL RECEPTICAL OUTLETS IN THE KITCHEN, DINING ROOM, PANTRY, OR OTHER SIMILAR ARAES. CEC 210.11 (C)(1). OCC OCC MD MD MD MD 42" GFI 42" GFI GFI GFI DIM DIM DIM GFI GFI MDSHUM130"GFI1 PROVIDE DISCONNECT SWITCH FOR MINISPLIT C.W. H.W. C.W.C.W.H.W.C.W. H.W. 2" VTR COTG 4 " P V C W A S T E 2 % s lo p e 2" PVC WASTE 2% slope 4" PVC WASTE2% slopeSEE SITE PLAN FOR CONNECTIONS2" VTR OMIT FIREPLACE (E) 100 A. Panel Meter UPGRADE TO 200 AMP PANEL. SUPPLY 100 AMP SUB TO ADU EXISTING 100 amp sub panel to be upgraded to 200 amp, supply 100 amp sub panel to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Ž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jdent1@charter.netStenger 1.7Single Family Residence Remodel & New ADU Addition1382 Aralia Ct.San Luis Obispo California 0WNER:Mary Kay Stenger1282 Aralia Ct.San Luis Obispo California 300'*/(1&31-"/0 8&"5)&33&4*45"/5 #"33*&3 &95&3*03(3"%& 1-:800%4)&"5)*/( 13&'"#53644 9#-,(8Ž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š)"4#&&/3&.07&%"54*--'03&"4&0' */45"--"5*0/"/%03$003%*/"5*0/0'05)&353"%&4 4$03&"/%'0-%8&"5)&33&4*45*7&#"33*&3"#07& )&"%&350"--08'03(3"$&7:$031-64*/45"--"5*0/ */45"--(3"$&7:$031-64)&"%'-"4)*/(6/%&3 8&"5)&33&4*45*7&#"33*&3.&$)"/*$"--:'"45&/"4 /&$&44"3: '0-%8&"5)&33&4*45*7&#"33*&3#"$,07&3)&"% '-"4)*/("/%4&"-4*%&&%(&48*5)8&"5)&33&4*45*7& #"33*&35"1&03(3"$&7:$031-64 /05&4      8 &"5)&33&4*45*7&#"33*&37& &3 8 &"5)&33&4*45*7&#"33*&37& &3 8 &"5)&33&4*45*7&#"33*&38 &"5)&33&4*45*7&#"33*&38 &"5)&33&4*45*7&#"33*&3        '0-%618&"5)&3#"33*&3 "/%5&.103"3*-:4&$63& &95&3*034)&"5)*/( 8&"5)&33&4*45*7&#"33*&3 */45"--("("-7*30/1"/ */4&"-"/5#&%13*0350 %003*/45"--"5*0/ 4&"-"/5 (3"$&7:$03/&303$03/&3 1"5$) (3"$&7:$031-64 SE TU TU OE SE UI UI UI */45"--#6*-%*/(1"1&3 4)*/(-&45:-&07&3)&"% +".#'-"4)*/( (3"$&7:$031-64 (3"$&7:$031-64   &95&3*03 4)&"5)*/(   %0/05'-"4)07&3#0550. /"*-*/('-"/(& .&$)"/*$"--:'"45&/"4/&$&44"3: */$03/&345)306()(3"$&7:$03 1-64 (3"$&7:$03/&303 $03/&31"5$) 3&$0..&/%&% */45"--#6*-%*/(1"1&34)*/(-& 45:-&07&3)&"% +".# "/%4*-- '-"4)*/(      $0/5*/60644&"-"/5#&"%! */5&3*034*%&0'/"*-*/('*/13*0350 */45"--"5*0/ 5:1  TU OE SE UI UI 7:$03š1-644&-'"%)&3&%'-"4)*/( ."/6'"$563&3 83(3"$&$0 8)*55&.03&"7&/6& $".#3*%(& ." 1)0/&   8&#XXXHSBDFDPOTUSVDUJPODPN */45"--(3"$&7:$031-64*/03%&3"44)08/#: /6.#&34 7*4*5(3"$&$0/4536$5*0/$0.'035)&.045 $633&/5%&5"*-4 */45"--"5*0/7*%&0"/%130%6$5 %"5"4)&&54 3*1$03%š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jdent1@charter.netStenger 1.7Single Family Residence Remodel & New ADU Addition1382 Aralia Ct.San Luis Obispo California 0WNER:Mary Kay Stenger1282 Aralia Ct.San Luis Obispo California & 32676%($06$1'+($'(56*5$'(25%(77(5 %/2&.67268332575(%$5 ,167$//:(/'(':,5()$%5,&,1/21*(6735$&7,&$//(1*7+6/$33,1*$7/($6721(0(6+ (0%('',$0(7(5;$1&+25%2/76,172&21&5(7( 2&0$;,080)520&251(56$1'63/,&(6 /$35(,1)25&,1*%$56$0,1,0802)',$0(7(5686(',$0(7(56#7(16,2163/,&(6 3529,'(&216758&7,21,62/$7,21$1'&5$&.&21752/-2,176$65(48,5('/2&$7(-2,17662$6 12772,03$,5675(1*7+$1'$33($5$1&(2)7+(6758&785(3/$&(,62/$7,21$1'&21752/ -2,176,16/$%621*5$'(720,1,0,=(5$1'20&5$&.,1*3/$&($3352;,0$7(/< 2& )250:25.6833257,1*9(57,&$/685)$&(60$<%(5(029('$)7(5$0,1,0802)'$<6 $//27+(5)250:25.0$<%(5(029('21/<:+(17+(&21&5(7(+$65($&+('2),76 ,1$//(;7(5,25:$//6:,7+;;3/$7(:$6+(56%2/7672%(3/$&('$7,1&+(6,1)5206+($5:$// $763/,&(6 '$<675(1*7+      :G#81/(66127('27+(5:,6(127(' 522)6+($7+,1*6+$//%(7+,&.81/(66127('27+(5:,6(3,:G# :22')25$%29(*5281'86(686($:3$/3 5(63(&7,9(/<$1'8%&67$1'$5'6 3/<:22'6+($7+,1*6+$//%(&';81/(6627+(5:,6(127(' 2526%(48$/ 35(6685(75($7&$1761$,/(56%/2&.,1*675,33,1*$1'6,0,/$5,7(06,1&21-81&7,21 /80%(5$1'3/<:22':,7+:$7(5%251(35(6(59$7,9(672&203/<:,7+$:3$&& :,7+522),1*)/$6+,1*9$325%$55,(56$1':$7(53522),1*2586(5(':22' 35(6685(75($76,//66/((3(561$,/(56%/2&.,1*)855,1*$1'6,0,/$5,7(06,1 68%)/225,1*$1')/2256+($7+,1*6+$//%(7 *7+,&.3/<:22'3, & % ' ',5(&7&217$&7:,7+&21&5(7( 6+($7+,1* % $ & $ 35(6685(75($7('/80%(5   7233,1*,686(',1:+,&+&$6(3529,'(%/2&.,1*%(7:((1678'6217232)%27720 $7$//:$//63529,'('28%/(7233/$7(6:,7+/$33('&251(56$1'67$**(5(' 63/,&(6:+,&+$5($0,1,0802) ,1/(1*7+$1'+$9(  G)$&(1$,/60,1,080 $7$//:$//63529,'($6,1*/(%277203/$7((;&(37:+(5($/,*+7:(,*+7&21&5(7( 678'3$57,7,216&217$,1,1*3/80%,1*+($7,1*2527+(53,3,1*6+$//%()5$0('$672 3/$7(:+(5(3/$7(6$5(&8725%25('3529,'(;0(7$/675$3($&+ *,9(3523(5&/($5$1&()253,3(6 3529,'(62/,';%/2&.,1*)25$//+$1'5$,/6 % ' 6,'(:,7+  G1$,/6 ( & $//$33/,&$%/(/2&$/$1'67$7(&2'(625',1$1&(6$1'5(*8/$7,216,1())(&7$6 :+(5(&216758&7,21'2&80(176&21)/,&7:,7+7+(&2'(67+(025(675,1*(176+$//$33/< %<'(),1,7,21&2175$&7'2&80(1766+$//,1&/8'(%87127%(/,0,7('727+( 7+()2//2:,1*'5$:,1*663(&,),&$7,2166758&785$/&$/&8/$7,21662,/65(3257 35,25727+(,668$1&(2)7+(%8,/',1*$1'25*5$',1*3(50,77+(5(6+$//%(12 75(1&+(625(;&$9$7,216 ),9( )((725025(,1'(37+,172:+,&+$3(5621,6 67$7(0$1'$7('(1(5*<&$/&8/$7,216$1'127(6*(2/2*<5(3257$&2867,&$/5(3257 $//)281'$7,21(;&$9$7,2166+$//%(,163(&7('$1'$33529('%<7+(62,/6(1*,1((5 7+(&2175$&7256+$//$55$1*()25$//7(67,1*$1',163(&7,2165(48,5('%<7+( 7+(63(&,),&127(6$1'7+(*(1(5$/6+28/'%(&/$5,),(':,7+7+(6758&785$/(1*,1((5 $//',0(16,216$1'(;,67,1*&21',7,2166+$//%(),(/'9(5,),('%<7+(&2175$&72535,25 7+('(6,*1$'(48$&<$1'29(5$//6$)(7<2)$1<(5(&7,21%5$&,1*6+25,1*7(0325$5< 68332576(7&,67+(62/(5(63216,%,/,7<2)7+(&2175$&725$1'+$6127%((17$.(1,172 &216,'(5$7,21%<7+($5&+,7(&7256758&785$/(1*,1((57+(&2175$&725,65(63216,%/( )257+(67$%,/,7<2)7+(6758&785(35,25727+($33/,&$7,212)$//6+($7+,1*$1'),1,6+ 0$7(5,$/62%6(59$7,219,6,76727+(6,7(%<7+($5&+,7(&7256758&785$/(1*,1((5'2 5()(5(1&(7+(6758&785$/&$/&8/$7,21625&2168/77+(6758&785$/(1*,1((5)25$16:(56 7248(67,2165(*$5',1*/80%(5*5$'(6256,=(65(48,5(')$67(1(56$1'25)227,1* $//:25.6+$//%(3(5)250(',1$6281'0$11(55(68/7,1*,1$&203/(7('352-(&7:,7+ $//0$7(5,$/6$66(0%/,(6$1'6<67(06&255(&7/<,167$//('3(57+(0$18)$&785(5 6 :25.3(5)20('6+$//&203/<:,7+7+()2//2:,1*$1'+$9(7+(6$0()25&($1'())(&76 7+()2//2:,1*127(6$1'63(&,),&$7,216$5(81/(66127('27+(5:,6(&21)/,&7%(7:((1 7+(&2175$&7'2&80(176$1'6+$//%(,03/(0(17('$&23<2)7+(62,/65(3257 $77+(%(*,11,1*2)($&+3+$6(2)&216758&7,21 ,()5$0,1*3/80%,1*(/(&75,&$/(7&  7+(2:1(5$5&+,7(&76+$//%(127,),('627+$7+(6+(0$<,163(&768&+:25.$1'$33529(25 $//5(&200(1'$7,216%<7+(62,/6$1'25*(2/2*<5(32576$5(&216,'(5('$3$572) )& 36,#'$<6)25)22,71*63$'66/$%6)& 36,#'$<6)25 '()250('5(,1)25&,1*%$561(:%,//(767((/$63(5$670$*5$'()25 &216758&7,21-2,1766+$//%(35(3$5('%<:,5(%586+,1*&/($1,1*$1'7+(1%586+,1* $**5(*$7(6$670&0$;6,=()25)227,1*6$1'0$;)25$//27+(5:25.  6$1' 6*5$'()2527+(56&/($1$1'815867('/$36$763/,&(6$1'3285 /$36$763/,&(6$1'3285/,1(672%(',$0(7(5625 0,1 81/(66127('27+(5:,6(  $//38030,;'(6,*166+$//%($33529('%<7+((1*,1((52)5(&25'35,2572,7686( :5,77(1$33529$/2)7+(6758&785$/(1*,1((52)5(&25'$33529$/%<7+(/2&$/%8,/',1* ',6$33529(7+(48$/,7<2)6$,'35,257212025(7+$1&203/(7,212)7+(:25. ',5(&7:,5(7,(6,172&21&5(7(:,5(7,(66+$//127%(',5(&7('72:$5'6(;326(' 7+(5(6+$//%(12'(9,$7,216)5207+(6758&785$/3/$16$1'25'(7$,/6:,7+2877+( 326,7,216833257$1'6(&85(5(,1)25&(0(17$*$,167',63/$&(0(17:,7+0(7$/&+$,56 5811(5663$&(56%2/67(5625+$1*(56$65(48,5('723529,'(5(48,5('&/($5$1&(6 &21&5(7(685)$&(60,1,080&/($5',67$1&(%(7:((162,/$1'5(,1)25&(0(176+$//%( ,1&+(681/(66127('27+(5:,6('212786('2%%,(62527+(50$6215<25&21&5(7( 7+((17,5(&216758&7,216,7(6+$//%($&&(66,%/(727+(),5('(3$570(173(56211(/%< 0($162)23(1,1**$7(6$&&(66/$''(562527+(50($16:+,&+:,//127352+,%,7),5( 5(48,5('72'(6&(1' &(0(177(67('7<3(3257/$1' $670& % 123($*5$9(/ :$7(5'5,1.$%/( ,1$3$67(2)1($7&(0(170257$5,00(',$7(/<35,2572&21&5(7,1* (;(&87,21 *  ' ( ) & *5$'(%($066(((;(&87,21127(6$1' ,163(&725'2(6127&2167,787($87+25,7<72'(9,$7()5207+(&2175$&7'2&80(176 6758&785$/&21&5(7(127(6 0$7(5,$/6 ),*+7,1*216,7(   $    $1'/2&$/,163(&72535,25723/$&(0(172)5(,1)25&,1* $''(1'806&+$1*(25'(56$1'&/$5,),&$7,216 6+28/'%(.(37216,7()257+('85$7,212)&216758&7,21 ,16758&7,216,1$0$11(5&216,67(17:,7+,1'8675<67$1'$5'6 &2175$&7'2&80(176$1'$1<$*(1&<+$9,1*-85,6',&7,212)7+,6 352-(&7 ,(/2&$/*5$',1*$1'+($/7+'(3$570(176   % $  $ 6,=(6$1'5(,1)25&(0(17 727+(&200(1&(0(172):25. 2)5(&25'35,25727+(&200(1&(0(1725:25. 127&2167,787(,163(&7,212)$1<2)7+($%29(,7(06     &855(17&%& 2)7+('$7(2)&216758&7,21'2&80(176 $6,)&23,('',5(&7/<,1727+(&2175$&7'2&80(176 *(1(5$/127(6  $ % & ',$0(7(5 $1'27+(5(0%(''(',7(06$1'7,*+772$//('*(6 6+($5:$//)5$0,1*$1'&211(&7,21127(6 ',$$1&+25%2/766+$//%(&$67,172&21&5(7(# 2&0$;,080 6<0%2/,1',&$7(6$6+($5:$//7+(180%(5,16,'(2)7+(6<0%2/ ,1',&$7(67+(7<3(2)6+($50$7(5,$/$66+2:1217+(6+($5:$//6&+('8/( 7+(6+($50$7(5,$/,6$33/,('217+()$&(2):$//:,7+7+(6<0%2/ %/2&.$1'1$,/$//-2,676$65(48,5(',16+($5:$// ,1',&$7(63/<6,'(6 )/2256$7$//:,1'2:$1''225-$0%6$1'$//32676:,7++2/''2:16 $7723$1'%277203/$7(672$1&+2572522)$1')/2256+($7+,1* $//6+($5:$//3$1(/6(;7(1'72)/22525522)6+($7+,1*$%29( $7$//6+($5:$//63529,'(0$7(5,$/$%29($1'%(/2:$//23(1,1*6 ('*(1$,/3/<72$//08'6,//67233/$7(2)'28%/(7233/$7(6723$1'%277202)$// :$//$1&+25$1&+25%2/7672%(86('$7:$//629(5)281'$7,21:$//G1$,/686(' $//(;7(5,25:$//6$1'522)72%(6+($7+(':,7+$3$5$7('&';0,1 ',$;$%# 2&(;&(37$6$%29( (32;,(6 6(7;3 )$&(62):$//$1'1$,/63$&,1*,6/(667+$13$1(/-2,1766+$//%(2))6(772)$// )25$1&+256,=($1'63$&,1*6(()281'$7,213/$1:+(5(3/<:22',6$33/,('21%27+ 0$7(5,$/%/2&.62527+(56758&785$/(/(0(176723529,'($326,7,9(&211(&7,21 6+($5:$//66+$//(;7(1')5206,//3/$7(72522)251')/225',$3+5$*086(6+($5 1$,/ &2//(&725 %/2&.,1*723/<:,7+6$0($6('*(1$,/,1*6((3/$1)25/2&$7,21 )$//21',))(5(17)5$0,1*0(0%(5625)5$0,1*6+$//%(; %(7:((1',$3+5$*0$1':$//66(('(7$,/6 :+(5(52:62)1$,/6$5(5(48,5('7+(<0867%(67$**(5(' G$1'G1$,/66+$//%(&200211$,/6 (;&(37:+(5(6+2:127+(5:,6( 6(()281'$7,213/$1   &2/')250('67((/78%,1*$670$*5$'(% :,7+$1,03(59,2860(0%5$1(%(7:((1($57+$1'&21&5(7( 678'63/$7(6$1'%/2&.,1**5$'(25%(77(5 -2,676$1'5$)7(56*5$'(25%(77(5 $33529('%<7+($5&+,7(&7$1'6758&785$/(1*,1((5 $//:22',1&217$&7:,7+&21&5(7(6+$//%(35(6685(75($7(':+(5(:22',61($5(5 7+$172($57+86(35(6685(75($7(5':22'81/(666(3$5$7('%<$&21&5(7(6/$% ',0(16,21/80%(56+$//+$9($0$;,08002,6785(&217(172)$77+(7,0(2)6+,30(17 $//:22'&211(&7256,1',&$7('6+$//%(%<6,0362167521*7,(81/(6668%67,787(6$5( ',0(16,21/80%(56+$//%(')/$5&+:,7+*5$'(,1',&$7('%(/2:81/(66127('27+(5:,6( 0$7(5,$/6 % $      67((/3,3($670$*5$'(%7<3((256 &855(17&%& %2/76$670$ 25$25$6,1',&$7(' *5$'($ */%7,0%(560867%()$%5,&$7(',1$1$33529('6+23%($066+$//%('))9 1$7,21$/'(6,*163(&,),&$7,21 1'6 &855(17(',7,21 *$/9$1,=,1*$670$)25$66(0%/('352'8&76$670$)2552//('35(66('$1' )25*(' / 6+$3(63/$7(6%$56$1'675,36*5($7(57+$17+,&.$670$)25 7+()2//2:,1*&2'(6$1'63(&,),&$7,2166+$//*29(51&216758&7,212)6758&785$/ ::3$25:&/,%67$1'$5'*5$',1*58/(6)25:(67(51/80%(5 :22'6<67(06 $ 7,0%(5 & ' ( %  363/<:22'67$1'$5'6 +27',33('*$/9$1,=(')$67(1(56    )/225)5$0,1* -2,6766+$//+$9($0,1,0802)2)%($5,1*21:22'250(7$/$1'2) /$3-2,67629(5683325760,1,080$1'1$,/:,7+  G7235(9(176(3$5$7,21 )8//+(,*+7%/2&.,1*81/(661$,/('72$1$'-2,1,1*678'25$1&+25('86,1*$ -2,6766+$//%(/$7(5$//<6833257('$77+((1'6$1'($&+6833257('%<62/,'; '(&.,1*,1&5$:/63$&(63529,'(&5$:/63$&($&&(66:,7+0,1,0806,=(; 3529,'(0,1,080&/($5$1&(81'(5%($06$1'*,5'(56$1'81'(5-2,676$1' 3529,'(62/,'%/2&.,1*:+(5()281'$7,21:$//(;&(('6 ,1+(,*+7)5$0( 678'60,1,080678'/(1*7+)25)281'$7,21:$//,6,)7+(:$//,66+257(5 3/$&(678'6:,7+:,'(',0(16,213(53(1',&8/$572:$//)5$0(&251(56:,7+7+5(( -2,6766+$//%(/2&$7('68&+7+$7$1<3/80%,1*250(&+$1,&$/3,3,1*+$65(48,5(' $//)/86+)250('-2,6766+$//%(+81*:,7+6,03621-2,676+$1*(567<3( +8 ( $1'6+($7+$65(48,5(')25$1$'',7,21$/6725< &/($5$1&(6 :$//)5$0,1* ) 81/(6627+(5:,6(127(' $  $ & ' 0(&+$1,&$/)$67(1(5 %($5,1*210$6215< %  6,03621 $//%($063(53(1',&8/$572:$//0867%(6833257('21326767+(6$0(7+,&.1(66$67+( 62/,';)8//+(,*+7%/2&.,1*81/(661$,/('72$1$'-2,1,1*678' 75866'(37+$732,172)6833257(;&(('63529,'(%5$&,1*$65(4 ')25:$//6 :+(5(75866(6$5(86('3529,'(62/,'%/2&.,1*$7$//32,1762)6833257:+(5( $//5$)7(566+$//%(/$7(5$//<6833257('$77+((1'6$1'$7($&+6833257%< 5$)7(566+$//%(1$,/('72$'-$&(17&(,/,1*-2,676:,7+$0,1,0802)  G1$,/6 3529,'(;5,'*(%2$5'6+,36$1'9$//(<6:+,&+$5($7/($67$6'((3$67+( 678'6$'-$&(1772&21&5(7(250$6215<:$//6+$//%(35(6685(75($7('$1'%2/7(' 3529,'('28%/(-2,67681'(5$//3$5$//(/3$57,7,216$1'62/,'%/2&.,1*81'(5$// 727+(:$//:,7+',$0(7(5$1&+25%2/76# 2&0$;,080 522))5$0,1* & % $ &87(1'2)7+(5$)7(56 ' 678'6$1'7+(6$0(:,'7+$67+(%($0  3(53(1',&8/$53$57,7,216        7+(&2175$&7256+$//&203/<:,7+7+()2//2:,1* $/6&&2'(2)67$1'$5'6)2567((/$1'%5,'*(6 6&$/(25$1<27+(5'(/(7(5,2860$7(5,$/6 6758&785$/67((/%$563/$7(6$1'52//('6+$3(6$670 $//:(/',1*72%('21(,1$1$33529('6+23),(/':(/',1*5(48,5(663(&,$/,163(&7,21 $,6&63(&,),&$7,216)257+('(6,*1)$%5,&$7,21$1'(5(&7,212)6758&785$/ $:66758&785$/:(/',1*&2'($1'25$1<$33/,&$%/(/2&$/5(*8/$7,216 $1<&21)/,&76%(7:((17+($,6&$1'$:6&2'(66+$//%(&/$5,),(':,7+7+(6758&785$/ $//67((/72%(&2$7('6+$//%(&/($1('72%$6(0(7$/$1'%()5((2)$//2,/65867 0$7(5,$/6   $ % & (1*,1((535,2572)$%5,&$7,21   67((/)25%8,/',1* $//*5$'(%($06$1'3,/(66+$//+$9(3(5,2',&63(&,$/,163(&7,213(56(& &21&5(7(6/$%72%($0,1,0802)$%29(),1,6+*5$'( #'$<6$1'5(,1)25&,1*6+$//%($670*5$'( 3527(&7&21&5(7()5203+<6,&$/'$0$*(255('8&('675(1*7+'8(72:($7+(5(;75(0(6 :($7+(5(;75(0(6'85,1*0,;,1*3/$&(0(17$1'&85,1*%<&203/<,1*:,7+7+()2//2:,1* 35,25723/$&,1*&21&5(7(5(029($//'(%5,6:$7(508'$1'/226(($57+)520 $//3,/(6$1'&$,662166+$//86(&21&5(7(:,7+$0,1,080675(1*7+2))&36, 67((/127(6    $ % (;&$9$7('$5($   ,1&2/':($7+(5$&, ,1+27:($7+(5$&, $//32676)5207+(522)0867%(&217,18(''2:172683325786,1*7+(6$0(6,=(0$7(5,$/ 5()(5(1&(&%&6(&7,216$1')2558/(65(*$5',1*7+(&877,1* $//+25,=217$/3/<:22'6+$//%(/$,':,7+)$&(*5$,13(53(1',&8/$572-2,6765$)7(56 3/<:22'1$,/,1*6+$//%(G#2&#$//('*(6$1'2&,17+(),(/'81/(66127(' &876+$3(&23(3/80%/(9(/$1'7851$//)5$0,1*0(0%(56723529,'()8//%($5,1* :+(5('28%/(3/$7(6$5(,17(55837('%<3267625%($06675$3:,7+6786,1* 326760$<%($5216,//3/$7(681/(6627+(5:,6(127('3529,'(62/,'%/2&.,1*  127&+,1*$1'%25,1*2)-2,676$1'678'6 $0,1,0802)  G($&+(1' %(/2:3267672)281'$7,21   27+(5:,6(#522)$1':$//6$1'2&#)/2256 $1':,7+67$**(5('-2,176 81/(66127('27+(5:,6(        $1<352'8&7612763(&,),&$//<&29(5(',17+($%29(5()(5(1&('67$1'$5'66+$// &203/<:,7+7+(5(&200(1'$7,2162)7+(352'8&70$18)$&785(5)257+(,17(1'('86( ,167$//)$67(1(56:,7+28763/,77,1*:22')$67(13$1(/352'8&7672$//2:)25 :$//)5$0,1*6+$//%(;#2&81/(66127('27+(5:,6(678'6*5($7(57+$1  )/2256+($7+,1*$1'68%)/225,1**/8('$1'1$,/('$6,1',&$7('217+('5$:,1*6 3529,'(0,1,0801$,/,1*3(5&%&7$%/( :$//$1'522)6+($7+,1*1$,/('$6,1',&$7('21'5$:,1*6 (;3$16,21$7-2,17681/(66127('27+(5:,6( )$67(16758&785$/6+($7+,1*$6)2//2:6 81'(5/$<0(171$,/('7268%)/225,1* $ 7$//0867%(;25;   & % '   (;(&87,21    6((3/$1 ,1$//)227,1*60,1  %$56&217 376,//3/$7( (6(65 )25',$$1'63$&,1* $% 6((6&+('8/( 6((3/$1 0,1'28%/((1'678'6 678'25%/2&.,1* )256,=($1'/2&$7,21 +2/''2:166((3/$1 7<3,&$/6+($5:$//(/(9$7,21 7+(&2175$&7256+$//86(,&%2$33529('6+273,16:,7+&$'0,80:$6+(56 2&0$; )5207+(&251(56$1'63/,&(6,1,17(5,25%($5,1*:$//681/(66127('27+(5:,6( &2162/,'$7(&$67,13/$&(&21&5(7(86,1*0(&+$1,&$/9,%5$7,1*(48,30(17$1'+$1' 52'',1*,1%('',1*$1'7$03,1*627+$7&21&5(7(,6:25.('$5281'$//5(,1)25&(0(17 86(6$0(3,16# 2&0$;,080)25,17(5,25121%($5,1*:$//6   %2/766+$//+$9(67$1'$5'&87:$6+(5681/(667+(<$5(%(,1*86(':,7+6758&785$/ /$*6&5(:66+$//%(7851(' 127'5,9(1 ,17235('5,//('+2/(62)7+(6+$1. 67((/0(0%(56+2/(6)25%2/766+$//%(127025(7+$1/$5*(57+$17+( 1$,/66+$//%($&20021:,5(1$,/ %2/7',$0(7(5 $ % )$67(1(56+$5':$5( &  6&$/(   2&0$;678'63$&,1* '28%/(3/$7( ('*(6 %/2&.$//816833257(' :5,77(1$33529$/2)7+(6758&785$/(1*,1((52)5(&25'$33529$/%<7+(/2&$/%8,/',1* 7+(5(6+$//%(12'(9,$7,216)5207+(6758&785$/3/$16$1'25'(7$,/6:,7+2877+( ,163(&725'2(6127&2167,787($87+25,7<72'(9,$7()5207+(&2175$&7'2&80(176 ' :5,77(1$33529$/2)7+(6758&785$/(1*,1((52)5(&25'$33529$/%<7+(/2&$/%8,/',1* 7+(5(6+$//%(12'(9,$7,216)5207+(6758&785$/3/$16$1'25'(7$,/6:,7+2877+( ,163(&725'2(6127&2167,787($87+25,7<72'(9,$7()5207+(&2175$&7'2&80(176 :$6+(5686(':,7+5(48,5('$1&+25%2/760867%(;;3/$7(:$6+(56 $//)/$6+,1*6+$//%(7:23$57)/$6+$1'&2817(5)/$6+$1'6+$//%(2) *$*$/93(5,1'8675<67$1'$5'6 ($&+:$< 3529,'(&&;25%(77(5$7(;326('($9(6 7+(52/,13$571(56+,3 *(1(5$/&2175$&725 6,*1(' '$7(' $5&+,7(&785$/(1*,1((5,1* &(// +$9(7+2528*+/<5(9,(:('7+(6(3(50,77('3/$16$1''(7$,/6$1'+$9(1248(67,216$77+,67,0(,)857+(581'(567$1'7+$7,$05(63216,%/()255(48,5,1*$//68%&2175$&725672$/625(9,(:7+(6(3/$167+2528*+/<$1'81'(567$1'$//7+(,1)250$7,21&217$,1(',17+(66+((76 ,03257$17127,&(7+($%29(67$7(0(170867%(6,*1('$1''$7('21$//66+((76$1'5(7851('727+((1*,1((52)5(&25' 7+(52/,13$571(56+,3 35,2572&200(1&(0(172)$1<:25.217+,6352-(&7 WKHUROLQSDUWQHUVKLS#JPDLOFRP '$7( 6&$/( 352-(&7 ,, 6,1*/()$0,/<5(6,'(1&(5(02'(/ 6$1/8,62%,632&$$$5$/,$&28570$5<.$<67(1*(5 (1*,1((52)5(&25'127(6*(1(5$/121( 6 0$7(5,$/6,'(C:\Users\robar\Documents\ArredDesigns\KenRolin\Stenger\Stenger1.dwg, 10/11/2023 12:43:20 PM, DWG To PDF.pc3 1 From:james dummit < Sent:Thursday, August 17, 2023 10:25 AM To:Steeb, Christine Subject:Form 602(o)pc Attachments:Dummit-Form 602 - 81723 Dummit.pdf 1 From:Ridgeway, Julie Sent:Tuesday, May 9, 2023 10:03 AM To: Subject:City of SLO Water Information Attachments:Utility Billing Adjustment Policy.pdf; Utility Billing Adjustment Form.pdf Hi James, As discussed, attached is the policy and form for the City’s Utility Billing Adjustment Committee. If you end up proceeding with a UBAC request, the form can either be submitted via email to ubac@slocity.org, mailed to or dropped off at our 879 Morro Street office, or filled out online here. While the application is in progress, there are three options on how to handle payment (below). If you have any questions about the committee or ever need to set up a payment plan, please feel free to reach out to our Utility Billing department at (805) 781-7133.  Pay the bill in full and if you are granted an adjustment then anything adjusted would be put towards future bills.  Make a partial payment. This helps customers not fall behind and have two bills later down the road.  Completely hold off on payment until after the UBAC process is complete. If you choose to hold off on payment, please know that if an adjustment is granted it is only on the water charges, so the full bill will not be relieved. Below is also a quick summary of the items we discussed verifying:  Starting at the meter, check to see if the leak indicator (the small triangle on the meter) is moving while no one is using water on the property. The meter at your property is a mechanical meter. If the leak indicator is turning while no one is using water, this would imply an active leak is occurring. If this happens, you can then turn off the water at the main building shutoff. If the leak continues to register on the meter this would imply that the leak is before the building shutoff. If the active leak stops registering, then that would imply that the leak is somewhere past that shutoff point. Please note, it is important to identify if your irrigation is tied in before or after the main building shutoff when doing this kind of isolation test.  If the property has an irrigation system, another action you may consider doing is to determine how much water the property’s irrigation system uses. You can do so by taking a meter read before and after the irrigation system runs. This helps customers get an understanding of the volume the system is using, instead of relying on the time or duration that the irrigation system is set to run. There is additional information about how to reach the meter and check for leaks on our Understanding Your Water Meter webpage, but please feel free to give me a call if there are any questions. Regards, Julie Ridgeway pronouns she/her/hers Water Resource Technician Public Utilities 2 879 Morro, San Luis Obispo, CA 93401-2710 E jridgewa@slocity.org T 805.781.7508 C 805.550.4011 slocity.org Stay connected with the City by signing up for e-notifications Utility Billing Adjustment Committee Submittal Form SERVICE ADDRESS STREET ADDRESS: ACCOUNT #: MAILING ADDRESS (IF DIFFERENT FROM ABOVE) NAME: STREET ADDRESS: CITY, STATE, ZIP: CONTACT INFORMATION HOME/CELL PHONE: EMAIL ADDRESS: THE ABOVE SERVICE ADDRESS HAD UNUSUALLY HIGH WATER USE DUE TO (CHECK ALL THAT APPLY): INDOOR PLUMBING LEAK (TOILET, SHOWER, ETC.) OUTDOOR PLUMBING LEAK (SERVICE LINE, SPIGOT) IRRIGATION LEAK EXCESSIVE IRRIGATION OTHER PLEASE EXPLAIN THE NATURE OF THE PROBLEM THAT CAUSED THE HIGH WATER USAGE (IF NECESSARY, YOU CAN USE AND ATTACH A SEPARATE SHEET OF PAPER): REPAIR RECEIPTS AND/OR OTHER DOCUMENTATION THAT LEAK HAS BEEN REPAIRED. REQUIRED. SIGNATURE OF ACCOUNT HOLDER DATE PRINT NAME Utility Billing Adjustment Policy I. DEFINITIONS As used in this policy, the following terms shall have the meanings specified below: a. “Customer” means the person or entity under whose name a water account is created and who is ultimately responsible for payment of all charges incurred on the account (Municipal Code 13.04.01). b. “Property-side leak” means any loss of water due to deterioration of pipes, fittings, or equipment, the existence of which is known or unknown to the property owner or tenant (customer), and said loss emanates from the coupling on the customer’s side of the water or recycled water meter or beyond, serving the customer’s property. c. “Committee” means the Utility Billing Adjustment Committee II. BACKGROUND The City Council through Resolution 8032 (1992 Series) created the Utility Billing Adjustment Committee and gave the committee the authority to resolve customer billing concerns, including the reduction of any amounts billed, as the Committee deems appropriate. The Committee is composed of one management representative each from the Finance, Utilities, and Administration departments. The Committee has the authority to establish the policies necessary for performing its duties. III. PURPOSE The purpose of this document is to establish a written policy for extending billing adjustments to water and sewer customers in the City of San Luis Obispo. The policy includes the requirements to request an adjustment; the standard billing adjustment that will be granted if all the requirements are met; sewer cap reevaluation requests; waiver of restore service fees; and variances to this policy. IV. POLICY A. Property Side Leaks Customers are responsible for the service and fittings attached to the Water Utility system beginning at the coupling on the customer’s side of the meter. Any leaks in the line-which are the responsibility of the customer-must be maintained and repaired by the customer solely and at his/her expense per the City’s Municipal Code Chapter 13.04. The customer’s service line, including the fittings on the customer’s side of the meter, is to be maintained in a state of repair sufficient to allow the removal and replacement of the meter for maintenance. No adjustment or credits will be given for leaks which develop because of changing or maintaining the water or recycled water meter, unless it can be shown that the Utility was negligent in performing the meter change or maintenance. The customer is responsible for monitoring higher than expected usage as reflected on the customer’s bill. Customers must investigate higher than expected usage to determine if the usage was caused by a property-side leak. A customer who has observed or has actual knowledge of a property-side leak is in violation of the City’s Water Conservation Regulations as defined in the City’s Municipal Code Chapter 13.07.010 and is required to promptly repair the leak. No adjustment or credit will be applied to the utility bill for the property-side leaks, damage, deterioration or other factors beyond the control of the City, except as defined under Section A.1 – Property-Side Leaks – Billing Adjustments. 1. Customer Adjustment Request Requirements: The Committee, or a designee of the Committee delegated the responsibility for adjusting utility billings, may adjust the water or recycled water usage portion (excluding service charges) and any resulting sewer usage portion (excluding service charges) on a customer’s bill when all the following requirements are met: a. WITHIN 60 DAYS OF LEAK: Customer shall notify City, in writing, of water or recycled water loss and repair of a property-side leak within 60 days from the bill issuance date for the period in which the loss occurred. b. ONE ADJUSTMENT EVERY 24 MONTHS: The customer has not received a property-side leak billing adjustmentk at any one service address in the past 24 months. The 24-month period begins the first month of the billing period following the last billing period for which a property- side leak billing adjustment was received. c. PAYMENT OF BILL: The City shall not extend the due date of a water, recycled water, or wastewater bill because of the customer submitting a request for an adjustment of a bill for a property-side leak. Customer shall pay at least the uncontested portion of the bill to prevent discontinuation of service. d. NEGLIGENT ACTS: There must be evidence that excessive use of water or recycled water was not due to the customer, his/her agents, or tenants’ willful or neglectful acts. e. LEAK MUST BE REPAIRED OR RESOLVED: If the excess usage is due to a property-side leak, the City must be satisfied that the problem that resulted in a request for a billing adjustment has been properly repaired or resolved. f. EVIDENCE OF REPAIR OR RESOLUTION: The City shall require repair bills or other appropriate documentation substantiating the repair of the property-side leak prior to approving a claim for adjustment. The written request shall be accompanied by either a plumber or landscaper’s invoice including a description of the repair work performed or a letter from the customer certifying: a. The name, address, and telephone number of the person discovering the leak; b. The date the leak was discovered; c. The nature and location of the leak; d. The date the leak was repaired; e. The name, address, and telephone number of the person repairing the leak; g. EXCESS WATER USE THAT WILL NOT BE ADJUSTED: The City will NOT extend any adjustments for excess water use due to left-on hoses, excessive irrigation (in time or frequency), or the neglect of wear-and-tear items such as toilet flappers, leaking faucets, water softening systems, and and any water distributing devices attached to the aforementioned items. 2. Standard Billing Adjustment a. The property-side leak billing adjustment shall be limited to one adjustment per 24-month period. The 24-month period begins the first month of the billing period following the last billing period for which a property-side leak billing adjustment was received. b. The property-side leak billing adjustment shall be limited to two consecutive billing periods. c. The property-side leak billing adjustment will be calculated on the following criteria depending upon customer class: i. Residential Accounts Single Family Residential customers’ water usage, because of a property-side leak, must exceed Tier 2 consumption and be at least 50% higher than usage compared to the previous billing cycle to qualify for a property-side leak billing adjustment. If the Committee or its designee grants a property-side leak adjustment, the amount of excess usage due to the property-side leak will be reduced by one-half the difference between the Tier 2 and Tier 3 rate. Example A. Leak Consumption 25 units B. Consumption > 12 units 13 units C. Tier 2 Rate $7.25 D. Tier 3 Rate $13.28 E. Difference between Tier 3 and Tier 2 $6.03 F. One-Half the Difference $3.01 G. Row B x Row F = Adjustment $39.13 ii. Multifamily Accounts Multifamily customers’ water usage, because of a property-side leak, must be at least 50% higher than usage compared to the previous billing cycle to qualify for a property-side leak billing adjustment. If the Committee or its designee grants a property-side leak adjustment, the amount of water usage more than the average usage at the property will be reduced by 22%. This is the same percentage reduction applied to residential accounts. Example A. Leak Consumption 25 units B. Average Consumption 10 units C. Leak Cons – Avg Cons 15 units D. 22% of Rate $1.56 E. Row C x Row D = Adjustment $23.40 iii. Dedicated Irrigation Accounts Dedicated irrigation customers’ water or recycled water usage, because of a property-side leak, must be at least 50% higher than usage compared to the previous billing cycle to qualify for a property-side leak adjustment. If the Committee or its designee grants a property-side leak adjustment, the amount of water usage more than the average usage at the property will be reduced by 22%. This is the same percentage reduction applied to residential accounts. Example A. Leak Consumption 25 units B. Average Consumption 10 units C. Leak Cons – Avg Cons 15 units D. 22% of Rate $2.33 E. Row C x Row D = Adjustment $34.95 iv. Commercial Accounts Commercial customers’ water or recycled water usage, because of a property-side leak, must be at least 50% higher than usage compared to the previous billing cycle to qualify for a property- side leak billing adjustment. If the Committee or its designee grants a property-side leak adjustment, the amount of water usage more than the average usage at the property will be reduced by 22%. This is the same percentage reduction applied to residential accounts. Example A. Leak Consumption 25 units B. Average Consumption 10 units C. Leak Cons – Avg Cons 15 units D. 22% of Rate $1.90 E. Row C x Row = Adjustment $28.50 If the excess usage is due to an indoor leak (not irrigation), no sewer usage adjustment will be given. If the excess usage is due to an outdoor leak, a sewer usage adjustment may be considered. The sewer usage adjustment (based on the excess usage) shall be limited to two billing periods and to one adjustment every 24 months. v. All Accounts – Unexplained Usage Billing Adjustment Customers can apply for one “unexplained” usage billing adjustment per the life of the account. The “unexplained” usage must reach Tier 3 for residential accounts and be at least 50% higher than normal usage compared to the same billing period in previous years for all accounts to qualify for a billing adjustment. Only one “unexplained” usage billing adjustment will be processed for the life of the account. The billing adjustment will be calculated per customer class as described under Section A.2 above. B. Sewer Cap Re-Evaluations Sewer Cap re-evaluations will only be processed for customers who had excess water usage due to a property-side leak that occurred during the most current sewer cap setting period. The sewer cap re-evaluation request for excess water usage due to a property-side leak must be received no later than October 1st. Requests for sewer cap re-evaluations due to any reason other than a property- side leak will not be considered. The re-evaluated sewer cap will be calculated by averaging the winter water consumption excluding the month that the leak occurred. C. Waiving Restore Fees The Utility Billing Adjustment Committee will not waive restore fees assessed when a customer’s water is properly shut off for non-payment. The restore fee is intended to recover the cost to the City for Utility Billing preparing the shut off and Utilities Services turning the water off and then back on so, because the City staff work has already been completed, the fee will not be waived. D. Variance Procedures Variances will be granted, on a case-by-case basis, at the discretion of the Committee. The following conditions are among those that may be given consideration in the variance process: • Granting a leak adjustment more often than once every 24 months; • Granting a sewer cap re-evaluation for a circumstance other than a property-side leak; • Granting a credit for more than two billing periods; • Granting a credit that exceeds the standard billing adjustment. The customer must request a variance in person, during a meeting with the Committee. E. Committee Decisions are Final With the Committee having been granted the authority to resolve utility billing concerns, their decision is final. Any customer who wished to appeal a committee decision may do so by bringing the City to court. 1 From:james dummit < Sent:Saturday, February 10, 2024 4:28 PM To:Hanh, Hannah Subject:Re: 3160 Johnson - Residential Development / Flexible Lot Design Subdivision Thanks Hannah I sent a copy of my Par. Map for 3100 Johnson - more accurately located, showing the actual location of the creek relative to the property line. I think it was just estimated on sheet 1 Site Plan jim On Feb 9, 2024, at 3:40 PM, Hanh, Hannah <hhanh@slocity.org> wrote: Thank you, Jim. I am confirming receipt of your three attachments. These have been forwarded to the Hearing Officer for their consideration at the hearing on Monday. Sincerely, Hannah Hanh Associate Planner <image001.png> Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 E hhanh@slocity.org T 805.781.7432 slocity.org <image002.png><image003.png><image004.png> Stay connected with the City by signing up for e-notifications From: james dummit < Sent: Friday, February 9, 2024 1:27 PM To: Hanh, Hannah <hhanh@slocity.org> Subject: Re: 3160 Johnson - Residential Development / Flexible Lot Design Subdivision This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Hi Hanna attached please find letter & exhibits for the community Development staff, and Mondays hearing thanks jim 2 On Feb 8, 2024, at 4:52 PM, Hanh, Hannah <hhanh@slocity.org> wrote: Hi Jim, The agenda and staff report for the Minor Subdivision hearing can be found here. As mentioned, this hearing would be limited to the review of the Tentative Parcel Map for the flexible lot design subdivision. Sincerely, Hannah From: Hanh, Hannah Sent: Friday, February 2, 2024 5:31 PM To: james dummit < Subject: RE: 3160 Johnson - Residential Development / Flexible Lot Design Subdivision Hello Jim, I also wanted to let you know that the Minor Subdivision Hearing for the flexible lot design subdivision is confirmed for Monday, February 12th at 1:30 pm at 919 Palm Street in Conference Room 1 (located in the lobby of our office). Public notices were mailed out today and the postcard should reach you shortly. I will follow up with a link to the agenda and staff report once it is published on the City’s website. Sincerely, Hannah Hanh Associate Planner <image001.png> Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 E hhanh@slocity.org T 805.781.7432 slocity.org <image002.png><image003.png><image004.png> Stay connected with the City by signing up for e-notifications 3 From: Hanh, Hannah Sent: Monday, January 29, 2024 11:18 AM To: james dummit < Subject: RE: 3160 Johnson - Residential Development / Flexible Lot Design Subdivision Sounds good – I will see you next Monday. To follow up, here is a link to the 02/05 ARC Agenda. The project at 3160 Johnson (see item 4.a for the staff report and project plans attachment) is the only hearing item. Let me know if you have any questions leading up to the meeting. Sincerely, Hannah Hanh Associate Planner <image001.png> Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 E hhanh@slocity.org T 805.781.7432 slocity.org <image002.png><image003.png><image004.png> Stay connected with the City by signing up for e-notifications From: james dummit < Sent: Saturday, January 27, 2024 9:26 AM To: Hanh, Hannah <hhanh@slocity.org> Subject: Re: 3160 Johnson - Residential Development / Flexible Lot Design Subdivision This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Thank you Hannah, for the update I plan to attend jim 4 On Jan 26, 2024, at 1:27 PM, Hanh, Hannah <hhanh@slocity.org> wrote: Hello Jim, Hope you have been doing well. I wanted to follow up and let you know that the residential development project at 3160 Johnson is scheduled for a hearing with the Architectural Review Commission (ARC) on Monday, February 5th at5:00 pm in the Council Chambers at 990 Palm Street. The ARC will be reviewing the building and site designs for four (4) new residences, and providing a recommendation to the Community Development Director who will make the final decision. Public notices for the ARC hearing are going out in today’s mail and should be reaching you shortly. The staff report, which includes information on the project scope, plans, etc., will be posted on the City’s website next week. I’ll follow up with a link to the agenda and report as soon as they are available. I also wanted to note that the project is also tentatively scheduled for a Minor Subdivision Hearing on Monday, February 12th. This hearing would be for the Tentative Parcel Map (i.e., flexible lot design subdivision) application to create four (4) new parcels. More details on this hearing will be provided as the date approaches. Sincerely, Hannah Hanh Associate Planner <image001.png> Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 E hhanh@slocity.org T 805.781.7432 slocity.org <image002.png><image003.png><image004.png> Stay connected with the City by signing up for e-notifications 1 From:Wong, Justin Sent:Friday, August 25, 2023 4:16 PM To:james dummit Subject:RE: 3100 Johnson Red Curb Painting Permit Thank you Jim, have a great weekend. Justin Wong Transportation Planner/Engineer I Public Works 919 Palm Street, San Luis Obispo, CA 93401-3218 E jwong@slocity.org T 805.781.7042 slocity.org From: james dummit < Sent: Thursday, August 24, 2023 3:20 PM To: Wong, Justin <jwong@slocity.org> Subject: 3100 Johnson Red Curb Painting Permit This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. Hi Justin attached original signed permit Thanks you Jim Dummit 1 From:building Sent:Friday, March 1, 2024 1:34 PM To:Dowty, Philip Cc:james dummit Subject:RE: 1382 Aralia Court; BLDG-2287-2023 Hi Philip, That sounds like a plan, I will wait for the documents to come my way. Feel free to reach out if you have any questions or issues with getting documents over to us. Thank you, Erin Stanley Permit Technician I Community Development E EStanley@slocity.org T 805.781.7159 slocity.org Stay connected with the City by signing up for e-notifications From: Dowty, Philip <PDowty@slocity.org> Sent: Friday, March 1, 2024 9:53 AM To: building <building@slocity.org> Cc: james dummit < Subject: RE: 1382 Aralia Court; BLDG-2287-2023 Thanks Erin, I have some of the documents listed but will follow up with James on the other items. Philip Dowty Engineering Consultant Mobile: 949.283.2270 Community Development E PDowty@slocity.org T 805.781.7171 slocity.org 2 Stay connected with the City by signing up for e-notifications From: building <building@slocity.org> Sent: Friday, March 1, 2024 8:53 AM To: Dowty, Philip <PDowty@slocity.org> Cc: james dummit < Subject: RE: 1382 Aralia Court; BLDG-2287-2023 Good morning Philip, Thank you for sending over the plans, is this the approved set? We will need to obtain all supporting documents as well for digital stamping and storage. We are currently missing digital copies of the below listed documents: - Assessors floorplan - Energy report - Structural calcs - Soils waiver We will need to obtain these digital documents before permit issuance. If you have any questions, please feel free to let us know. Thank you, Erin Stanley Permit Technician I Community Development E EStanley@slocity.org T 805.781.7159 slocity.org Stay connected with the City by signing up for e-notifications From: Dowty, Philip <PDowty@slocity.org> Sent: Thursday, February 29, 2024 3:16 PM To: building <building@slocity.org> Cc: james dummit < Subject: 1382 Aralia Court; BLDG-2287-2023 Hello Building, This application is “Ready for Action” by all departments, but the applicant was having trouble sending his electronic files. He has sent me the pdf’s and I’ve attached them for your use. Does this work for you, or is something else needed? I’ve included him on this email so you can “Reply All” if he needs to provide anything else. You can also call me with any questions. 3 Thank you, Philip Dowty Engineering Consultant Mobile: 949.283.2270 Community Development E PDowty@slocity.org T 805.781.7171 slocity.org Stay connected with the City by signing up for e-notifications 1 From:Miller, Katherine Sent:Wednesday, May 22, 2024 9:21 AM To: Subject:SLOPD 602/ No Trespassing Form Hello, My name is Katherine Miller and I am a Dispatch Supervisor with the San Luis Obispo Police Department. We received your 602 letter for 2074 and 2078 Parker St. I wanted to inform you that our department is no longer accepting paper forms and has switched to an online version. We have accepted the form as a one-time courtesy but from now on all 602 information will need to be submitted using the following link: https://forms.slocity.org/Forms/L602 The form can only be used for 1 address so you would need to submit two forms in this case. Please let me know if you have any questions. Thank you and have a great day! Katherine Miller Communications Supervisor Police Department 1135 Roundhouse, San Luis Obispo, CA 93401-2729 E KMiller@Slocity.org T 805.594.8022 slocity.org Stay connected with the City by signing up for e-notifications This e-mail, and any files transmitted with it, are intended only for the person or entity to which it is addressed and may contain confidential, protected, and/or privileged material. Any review, re-transmission, dissemination or other use of, or taking of any action in reliance upon this information by persons or entities other than the intended recipient, is prohibited. If you received this in error, please contact the sender and delete the material from any computer. 1 From:Silva, Ilianna Sent:Monday, December 11, 2023 7:35 AM To:james dummit Subject:RE: LDG-2287-2023 (1382 Aralia Ct San Luis Obispo, CA 93401) - V1 Comments Thank you. We are open today from 1pm-4pm. Ilianna Silva Permit Technician I Community Development E ISilva@slocity.org slocity.org Stay connected with the City by signing up for e-notifications From: james dummit < Sent: Friday, December 8, 2023 4:46 PM To: Silva, Ilianna <ISilva@slocity.org> Subject: Re: LDG-2287-2023 (1382 Aralia Ct San Luis Obispo, CA 93401) - V1 Comments This message is from an External Source. Use caution when deciding to open attachments, click links, or respond. I will pick up plans Monday ok? thank you jim Dummit On Dec 8, 2023, at 3:09 PM, Silva, Ilianna <ISilva@slocity.org> wrote: Hello, I am just following up with this project. We have plans sets available for pick up at the counter. Will you be picking up the plans or can we recycle them for you. 2 Please let me know if you have any questions. Thank you. Ilianna Silva Permit Technician I <image001.png> Community Development E ISilva@slocity.org slocity.org <image002.png><image003.png><image004.png> Stay connected with the City by signing up for e-notifications From: Silva, Ilianna Sent: Friday, September 22, 2023 12:35 PM To: Subject: LDG-2287-2023 (1382 Aralia Ct San Luis Obispo, CA 93401) - V1 Comments Hello,   Please find the attached comment letters for this project. Please address corrections and provide responses with your re-submittal. We will have the plan sets available for pickup here at the office during open hours. Thank you! Counter Hours:   Monday & Wednesday 1:00pm – 4:00pm   Tuesday & Thursday 9:00am – 12:00 pm   Friday – Closed (by appointment only) Ilianna Silva Permit Technician I <image001.png> Community Development E ISilva@slocity.org slocity.org <image002.png><image003.png><image004.png> Stay connected with the City by signing up for e-notifications 1 From:building <building@slocity.org> Sent:Thursday, February 8, 2024 10:08 AM To: Subject:1382 Aralia BLDG-2287-2023 V2 Comments Attachments:BLDG-2287-2023_Review_v2.docx Hello,   Please find the attached comment letters for this project. Please address corrections and provide responses with your re-submittal. We will have the plan sets available for pickup here at the office during open hours. Thank you! Counter Hours:   Monday & Wednesday 1:00pm – 4:00pm   Tuesday & Thursday 9:00am – 12:00 pm   Friday – Closed (by appointment only) Thank you, Erin Stanley Permit Technician I Community Development E EStanley@slocity.org T 805.781.7159 slocity.org Stay connected with the City by signing up for e-notifications Date: January 31, 2024 Plan Check Review # 2 Staff Response: Review #1 Review #2 Review #3 Review #4 (Additional Fees) Applicant Response: Please indicate here if any new changes have been made to the plans that are not a result of the corrections from this list. Briefly describe the type of changes and their location on the plans. Check one: _____yes ______no Print Name: If yes, please briefly describe the changes and where they are located on the plans: Project Address 1382 Aralia Ct Project Name Stenger Residence Application Number BLDG-2287-2023 Review of Single Family Residence Remodel with new attached ADU Occupancy Class Click or tap here to enter text. Construction Type Click or tap here to enter text. Occupant Load Click or tap here to enter text. Sprinklers Click or tap here to enter text. 1 2 3 4 Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 2 Engineering Development Review Phil Dowty, Consultant Engineer pdowty@slocity.org Phone (949) 283-2270 ☐ Ready for Action ☒ Needs Resubmit ☐ OK for Counter Re-Check ☒ Final Inspection Required (staff reminder: add yourself to final inspection in permit module) 1. Add Standard Public Works Notes: The following notes shall be included on the cover sheet of the building plans, the architectural site plan, and/or grading plans as appropriate: a. All work located within the public right-of-way or within the jurisdiction of the Utilities and Public Works Departments shall comply with the most current edition of the Engineering Standards and Standard Specification. (The current adopted Standards are dated August 2020.) b. A separate encroachment permit is required for any work in the public right-of-way, within city easements, or for connections to public utilities. Work requiring an encroachment permit includes but is not limited to demolitions, utilities, water, sewer, and fire service laterals, curb, gutter, and sidewalk, driveway approaches, sidewalk underdrains, storm drain improvements, street tree planting or pruning, curb ramps, street paving, and pedestrian protection or construction staging in the right-of-way. c. Any sections of damaged or displaced curb, gutter & sidewalk, or driveway approach shall be repaired or replaced to the satisfaction of the Public Works Director. d. Contact the Public Works inspection hotline at 781-7554 with at least a 48-hour notice for any required encroachment permit inspection or final inspection. e. The adjoining street shall be cleaned by sweeping to remove dirt, dust, mud and construction debris at the end of each day. f. A traffic and pedestrian control plan shall be submitted to the Public Works Department for review and approval prior to encroachment permit issuance. g. Any existing survey monuments shall be protected in place or shall be tied out by a licensed land surveyor prior to disturbance and then replaced prior to occupancy in accordance with Section 8771 of the California Business and Professions Code. h. Erosion control measures shall be implemented and maintained to the satisfaction of the Building Official and Public Works Director during all demolitions, construction and ground disturbing activities.  (2nd P/C) Notes have been added, however please add missing note “g” Response: ______________________________________________________________________ 2. Provide a copy of the Project Soils/Geotechnical Report. Response: ______________________________________________________________________ Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 3 3. Provide a review memo, or signed statement on title sheet, from Soil/Geotechnical Engineer indicating they have reviewed the plan and plans conform to their recommendations. Response: ______________________________________________________________________ 4. Add Earthwork Quantities.  (2nd P/C) Earthwork quantities have been added indicating 0 cys on the cover sheet, however this is in conflict with a note on sheet A0.4 where 26cys of cut is identified for the patio/wall grading. Please revise or provide a response to explain the discrepancy. Response: ______________________________________________________________________ 5. Provide a Vicinity Map showing a more general project location than shown on the tract map image on sheet AO. Response: ______________________________________________________________________ 6. Identify any existing trees with trunks larger than 3 inches, indicate if trees are to be protected or removed. Removal of trees may require separate tree removal permit and coordinated with Planning Division and City Arborist.  (2nd P/C) Existing trees have been added however please add the species of the tree to be removed to confirm a removal permit will not be required. Response: ______________________________________________________________________ 7. Provide grading and drainage information, the information provided on the Site Plan, sheet AO is conceptual only and difficult to read. Grading information should include the following information:  Finish grade/surface elevations at building corners and as needed to verify finish grading at foundation and drainage away from building to the street.  Add a general drainage and grading note to indicate exposed earth adjacent to foundation to be 8” (min) below finish floor, or untreated wood (CBC2304.12.1.2). Improved surface to be 2” below weep screed (CBC2512.12); minimum slope away from foundation to be 5% (dirt), or 2% (improved surface) (CBC1804.4).  Show landings at doors with FS elevations. Minimum requirements for finish grading at foundation: Response: ______________________________________________________________________ Site Plan, Sheet AO 8. Consider a larger scale (1”=10” ?) for a more clear site plan, include the following:  Add Bearings to the lot line dimensions and add length with radius for front property line. o (2nd P/C) Property dimensions have been added, however please verify radius of front property line, our records indicate the radius is 44ft.  The PUE and Tree easements are incorrectly shown and should be within the lot. o (2nd P/C) Easement has been revised however please correct the drafting to indicated 10ft “Tree Easement” and 6ft “P.U.E.” – image below. Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 4  Label existing curb and provide a 10’ dimension from top of curb to property line.  Label Aralia Ct.  Show all existing and proposed wet and dry utilities on the Site Plan or other appropriate sheet; include existing sewer and water main sizes and materials (see image below). Identify existing water meter and label size (1”meter on 1” service lateral).  (2ND P/C) Utility information has been added, however please identify the existing water main to be 4” PVC-C900, and the existing sewer main to be 6” PVC. Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 5 Storm Water Quality 1. The project shall show and document compliance with the 2014 Post Construction Stormwater Regulations as promulgated by the Regional Water Quality Control Board. The building permit application shall include the required PCR checklist to show compliance with any pertinent standards. The checklist is available at the following link: http://www.slocity.org/home/showdocument?id=5190 . If upon completion of the checklist, the project is determined to be a non-Regulated Project, include the following Stormwater Compliance Block on the coversheet: STORMWATER COMPLIANCE SUMMARY: The Project is not a Regulated Project subject to Regional Water Quality Control Board Resolution R3-2013-0032 “Post Construction Stormwater Management Requirements for Development Projects in the Central Coast Region” based on the following: X Project does not create and/or replace 2,500 square feet or more of impervious area Project type is listed in Section B.1.b (state which): Response: ______________________________________________________________________ Engineering Development Review Phil Dowty, Consultant Engineer pdowty@slocity.org Phone (949) 283-2270 ☐ Ready for Action ☒ Needs Resubmit ☐ OK for Counter Re-Check ☒ Final Inspection Required (staff reminder: add yourself to final inspection in permit module) 9. Add Standard Public Works Notes: The following notes shall be included on the cover sheet of the building plans, the architectural site plan, and/or grading plans as appropriate: i. All work located within the public right-of-way or within the jurisdiction of the Utilities and Public Works Departments shall comply with the most current edition of the Engineering Standards and Standard Specification. (The current adopted Standards are dated August 2020.) j. A separate encroachment permit is required for any work in the public right-of-way, within city easements, or for connections to public utilities. Work requiring an encroachment permit includes but is not limited to demolitions, utilities, water, sewer, and fire service laterals, curb, gutter, and sidewalk, driveway approaches, sidewalk underdrains, storm drain improvements, street tree planting or pruning, curb ramps, street paving, and pedestrian protection or construction staging in the right-of-way. k. Any sections of damaged or displaced curb, gutter & sidewalk, or driveway approach shall be repaired or replaced to the satisfaction of the Public Works Director. Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 6 l. Contact the Public Works inspection hotline at 781-7554 with at least a 48-hour notice for any required encroachment permit inspection or final inspection. m. The adjoining street shall be cleaned by sweeping to remove dirt, dust, mud and construction debris at the end of each day. n. A traffic and pedestrian control plan shall be submitted to the Public Works Department for review and approval prior to encroachment permit issuance. o. Any existing survey monuments shall be protected in place or shall be tied out by a licensed land surveyor prior to disturbance and then replaced prior to occupancy in accordance with Section 8771 of the California Business and Professions Code. p. Erosion control measures shall be implemented and maintained to the satisfaction of the Building Official and Public Works Director during all demolitions, construction and ground disturbing activities. Response: ______________________________________________________________________ 10. Provide a copy of the Project Soils/Geotechnical Report. Response: ______________________________________________________________________ 11. Provide a review memo, or signed statement on title sheet, from Soil/Geotechnical Engineer indicating they have reviewed the plan and plans conform to their recommendations. Response: ______________________________________________________________________ 12. Add Earthwork Quantities. Response: ______________________________________________________________________ 13. Provide a Vicinity Map showing a more general project location than shown on the tract map image on sheet AO. Response: ______________________________________________________________________ 14. Identify any existing trees with trunks larger than 3 inches, indicate if trees are to be protected or removed. Removal of trees may require separate tree removal permit and coordinated with Planning Division and City Arborist. Response: ______________________________________________________________________ 15. Provide grading and drainage information, the information provided on the Site Plan, sheet AO is conceptual only and difficult to read. Grading information should include the following information:  Finish grade/surface elevations at building corners and as needed to verify finish grading at foundation and drainage away from building to the street.  Add a general drainage and grading note to indicate exposed earth adjacent to foundation to be 8” (min) below finish floor, or untreated wood (CBC2304.12.1.2). Improved surface to be 2” below weep screed (CBC2512.12); minimum slope away from foundation to be 5% (dirt), or 2% (improved surface) (CBC1804.4).  Show landings at doors with FS elevations. Minimum requirements for finish grading at foundation: Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 7 Response: ______________________________________________________________________ Site Plan, Sheet AO 16. Consider a larger scale (1”=10” ?) for a more clear site plan, include the following:  Add Bearings to the lot line dimensions and add length with radius for front property line.  The PUE and Tree easements are incorrectly shown and should be within the lot.  Label existing curb and provide a 10’ dimension from top of curb to property line.  Label Aralia Ct.  Show all existing and proposed wet and dry utilities on the Site Plan or other appropriate sheet; include existing sewer and water main sizes and materials (see image below). Identify existing water meter and label size (1”meter on 1” service lateral). Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 8 Response: ______________________________________________________________________ Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 9 Storm Water Quality 2. The project shall show and document compliance with the 2014 Post Construction Stormwater Regulations as promulgated by the Regional Water Quality Control Board. The building permit application shall include the required PCR checklist to show compliance with any pertinent standards. The checklist is available at the following link: http://www.slocity.org/home/showdocument?id=5190. If upon completion of the checklist, the project is determined to be a non-Regulated Project, include the following Stormwater Compliance Block on the coversheet: STORMWATER COMPLIANCE SUMMARY: The Project is not a Regulated Project subject to Regional Water Quality Control Board Resolution R3-2013-0032 “Post Construction Stormwater Management Requirements for Development Projects in the Central Coast Region” based on the following: X Project does not create and/or replace 2,500 square feet or more of impervious area Project type is listed in Section B.1.b (state which): Response: ______________________________________________________________________ Building DEPARTMENT Review #2 ☐ Ready for Action ☐ Needs Resubmit ☒ OK for Counter Re-Check ☐ Final Inspection Required (staff reminder: add yourself to final inspection in permit module) Note: The following comment or partial comments remain from the plan review dated September 13, 2023. These comments are minor and could be approved in a scheduled recheck meeting. Sean McCaffrey, E smccaffrey@slocity.org, C 805.440.6617, P 805.781.7168 Plans Examiner Community Development Review #2: Hal Hannula, hhannula@slocity.org, (805) 783-7853 Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 10 1. Missing fire separation from ADU to SFD. (§ 302.3 CRC) 2. Need soil exemption if not providing geo report. https://www.slocity.org/home/showpublisheddocument/25356/637169433911870000 (§ 106.2 CRC) 3. Call out Beam size for #5 on structural plans. 4. Provide cut sheet for tile so dead weight can be verified to be 10 PSF as structural calculation shows. 5. Due to the vaulted ceiling unvented attic condition needs to be completed. Call this out on the plans and show how this is accomplished. (§ 806 CRC) 6. Structural general notes for the shear wall need to show 3x members due to the nail spacing on each panel being 3” O.C. Also call out base plate washer for anchor bolts maximum ½” aware from sheathing. (§ 4.3.7.3 SDPW2021) 7. Provide minimum footing depth for all exterior and interior footings. Change this on plans. (§ SLOMC 15.04.020 (FF)). Soils Engineer exemption letter received. Show and note compliance with the City of SLO minimum footing requirements per amended Table 1809.7. Revise all plan notes and details accordingly. Response (Include Sheet and Detail Number): 8. Provide footing point load calculation for structural ridge beam to post. (§ 106.2 CRC) 9. Provide electrical load calculations. (§ 230.42 CEC) Provide load calculations for the residence and ADU combination. Verify that the existing 100A panel is adequate and has capacity for the ADU. Include a list of the loads for reference. Revise the plans to clarify that the new ADU panel is a subpanel. Provide a minimum 100A panel for the ADU per the CEC. Response (Include Sheet and Detail Number): 10. Provide water calculations showing meter and service size line that shows size is adequate. (610 CPC ) 11. Provide a DWV plan. (§ 106.2 CRC) 12. Provide a mini split disconnection switch (§ 301.4 CMC) 13. Provide aging-in-place requirements and put on plans. (§ 327 CRC) 14. Provide fireplace detail and manufacture specifications. (§ 303.1 CRC) 15. Provide a combo SA/CM alarm due to the gas appliance. (314 CRC) 16. Missing exhaust fan in bathroom. (§ 302.3 CRC) 17. Provide a site address that’s visible from ROW (§ 319 CRC) 18. Missing outlet at the end of the kitchen counter. (§ 210.52 (C) CEC) 19. Missing strap for the continuation of lateral forces from beam to the shear wall at Roof grid line A / ~2.8 (§ 602.3.2 CRC) Fees / Addressing Vanessa Nichols vnichols@slocity.org Phone 805-781-7588 ☐ Ready for Action ☒ Needs Resubmit ☒ OK for Counter Re-Check ☐ Final Inspection Required (staff reminder: add yourself to final inspection in permit module) Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 11 1. Address assigned to new ADU is 1382 A Aralia Court. Please update all plan sheets to reflect the newly assigned address. 2. Please note the location and size of the existing water meter on the Site Plan. 3. Final fees pending other department reviews. No action required. Utilities Department Ryan Beech Rbeech@slocity.org and (805) 781-7033 ☐ Ready for Action ☒ Needs Resubmit ☐ OK for Counter Re-Check If you have questions on the above items, please contact Wastewater Collection System Supervisor, Ryan Beech, at 805-781-7033, or by e-mail: Rbeech@slocity.org 1. The existing sewer lateral shall be inspected per Chapter 13.08.395 of the City’s Municipal Code and the inspection shall be submitted with the building permit submittal. Submit the inspection video to Ryan Beech, Community Development, Engineering Development Review. Planning Walter Oetzell, Assistant Planner (805) 781-7593 | woetzell@slocity.org ☐ Ready for Action ☒ Needs Resubmit (see below) On review of the proposed plans, the following comments are provided: 1. Project Description, Scope of Work. Plans depict construction of a new retaining wall (in replacement of a portion of an existing wall), but the Project Description on Title Sheet of plans does not include this work. Revise the Project Description to describe all work within the scope of the permit, consistent with depiction in plans. (v3: Project Description revised, though still does not described construction of new walls) 2. Retaining Walls and Fences. Indicate the height of fencing at the property line wherever retaining walls over three feet in height are proposed within five feet of the property line. Please note that where fences are located on retaining walls within setbacks, fences are not to exceed six feet as measured from the uphill side, and the combined fence and retaining wall height is not to exceed nine feet from the lower side (Zoning Regulations §17.70.070 (F)). (v3: fence height given as five feet. Portions of walls near property lines appear to rise 2 ½ each segment, such that fencing at conforming (combined) height is feasible) Plan Check Review #2 1382 Aralia Ct BLDG-2287-2023 Page 12 3. Grading. Clarify whether installation of the taller retaining wall involves grading (cut or fill) activity. Provide spot elevations for grade and finish surface at top of wall and bottom of wall (low side), sufficient to describe the height of the proposed wall over its entire extent, as measured from the low side of the wall. (v3: grading information added to plans)