HomeMy WebLinkAboutPRR24250_2/'\\ Net w u [{< MBMORANDUM To: Date:1 From: Hal Subject: Graphic Bill Mitchell, the superin block structure that he is you will want to route it a copy of the plan check 1997 G. Hanson, Fire to All that we are looking for the driveway entrance (in words as long as it is between 4'-6" and 6' Mr. Mitchell's Building Permit Coordinator Panel S Broad Street, Marigold Center Center, faxed me a copy of the concrete split faced the graphic annunicator panel (GAP). I'm sure that Planning , and Building/Grading. We included t to you for the fire-alarm system. face northerly, be supported substantiallY, and be close to do not have any opinion as to what the structure looks like visible)., our GAP Standard requires the GAP to be located so as to be visib first arriving emergency personnel. number, fax number it shown on the first page 05/01/s? TIIU 14:49 FAX 8057828809 CHQ @ ITARIGOLD @ oor CHg lrucrlic II, Inc" rtInrigold Center - 0n ,\ile Ollitt 399il llroail Slreel r $'grr l.uis Ohislto, (',,1 9"1401 0s 782-8800 t I:rlX 80s 78)-,Y809 llA'l'li: May1,1gg7 't.lt\ili sliN'l':3:55pm T-O:Ron Hanson Frlx NLtNllt lt: s43-8019 lillt[l: city of SLo - FIRE DEPT.lltAil, 0lil(J.?: No Flt(|lll: Birt Mitchetl 't'(t'l'AL I,AGtis: * 4 (lnchrrling llris cover page) ITIi: To follow is the location of Annuciator O5/OI/97 THU 14:50 FAX 805?828809 CIIQ @ MARIGOLD rg 002 ,) Inlrstrtal V'la / tr a'(\ F $r *t: \$s r-t orh s-:r ci \ I 05/01/e? THU 14:51 FAX 805?828809 @a @ oos a a ,, gl ttq6lh SAW CUTTI}IG, BREAKING, DRIILING ANO NEMOVAT s heet natr I {'tesh r n X y^t *A" L ,' hnnordtat' SiXn f"J istal $o' firru*cirt'P, f,t';u , Jlu -rl lr s J-{ a J' z-- -.-'l'3 . Lo$. San a {7titl ttz.el$o lflgl321-01$(ilrf irr-3810 Cornlt: ll05l l;Z'llBS! . San tcandro: {{15} t5t'8010 . Escondldo: l8l9l f89'1014 r San Dlego: 16191 203-720t1 r Senll Clrm: {{08f gt0'9l9il r San Fernendo Velley: (tl81 504'0033 Construr:lion Sat vices Divisiot I (sr8t 380-r5r9 - 05/0t/97 TIIU 14:52 FAx 8057828809 & 004 sAw curill{G,BREAKIITIG, DRITLING AND REII/IOVAI l'-o" --.-- l ,,rrrlrrrt lion Setvices Division -l I rlri I /1 s Split ld BI otlq h e I \ntt rtCtat nt I . lAnahelm: l7t{l ttt-tl6o. Los Angchr: l2ltl l2l-Ol3l r San Bfinrrdlnc (?lll t?t-3880 , Jenluru Counly: Goll lt2-!834 r Saeremrnto: (9101 StGlStg l'..lt.Lt r Sen Leandro: 14l5l 35t.8U10. Eseondldo: (B19| 189-1014 ' San Dlego: 16191 2e3-726t1 r Senla Clara: 14081 970-9494 r San Fernando Volley: GlE, 504-0033 r.r .1 I r b a - Lu.L r-tl! frnryh 3r ale j FIRE DEPARTMENT PLAN CHECK - FIRE ALARM SUBJECT: OWNER: ADDRESS: JOB NUMBER: DATE ROUTED: DATE COMP.: PLAN CHECKER: PROJ. MANGR.: Fire Alarm System for all of the Buildings in the Marigold Center Marigold Ventures 3950 Broad - Main File for Site 97-025 PLAN CHECK #1 Feb. 11,1997 Feb. 27, 1997 (11 working daYs) Ronald G. Hanson, Fire lnspector/Plan checker (805) 781-7379 Marion Todd, Ph# 541-4470 SHEET 1 OF 5 ptans submitted have been reviewed for compliance with the appropriate standards as indicated below. Unless otherwise noted, all code references are from the current editions of the appropriate codes. Devices installed must comply with minimum NFPA and UFC requirements' ADA requirements have not been review by the Fire Department. The applicant is advised to investigate any additional ADA requirements which may be required. 1) provide record drawings and certification of the fire alarm system in accordance with NFPA 72, Sec. 1.7.2 prior to final approval' 2l All signals shall be monitored by a UL listed monitoring station. lf Valley Alarm is used they must monitor tamper and trouble signals also' 3) Please revise voltage drop and battery calculations to show all proposed devices. 4l Submit cut sheets for all devices, wiring, and appliances proposed or used' provide Ul-listing and CSFM approvals. The following items need to be included this submittal; rate of rise heat detector, HVAC duct detection, tamper devices for os&Y valves, wiring, graphic annunciator panel (type of panel & pedestal), key pad (D1256), dual phone modula (D928 or D12Bl, & the monitoring equipment used for class-1 hoods' b) The owner shall hire a qualified agency to provide maintenance inspections as required by NFpA 72 and UFC on at least a quarterly basis. Please provide a maintenance contract for our files. All devices within the complex shall be reviewed within a Years time. ZI Sheet 2 ot 5 135O Broad Street General File - Fire Alarm for Marigold Center PC#97-025.pc1 6)Alarm Signal - The alarm signal shall be keyed to one half to one second "on" and one -second "off" for three cycles. The alarm signal shall be_ repeated for the duration that the fire alarm system is activated. IUFC 1007.3.3.3.21 Connections to Other Systems - A fire alarm system shall not be used for any p*p*" "th"r tn.n tire warning unless approved by the authority having jurisdiction. IUFC 1 007.3.3.4a1 Supervision - Means of interconnection equipment, devices and appliances shall br r"prt"ired for the integrity of the interconnecting conductors or equivalent, as set forth in UFC Standard 1O-2. a. Show how the external power supply is wired into the FACP. Provide the following information on the single line (riser) diagram': 8). 9) Conductor information, including size, stranding, insulation type, etc ICEC, Article 7601 Conduit fill calculation or NEC reference. [CEC, Table #4] Location of end-of-line devices. t1994 UFC, 1O01 '31 lnclude zone descriPtions. 1O). All required fire detection systems installed within the jurisdiction shall be supervised by a central station listed by Underwriters Laboratories for receiving fire alarms. d provide a U.L. "Central Station Signaling System Certificate" for Valley Atarms. tuFc 1007.3.3.6.1 as amended by M.C. 15.08.2701 11)Annunciation - a. Each building shall be considered as a separate zone. b. Each device within each building shall be considered a separate zone within that building. As a minimum the following zones snali Oe represented for each building weather used or not. 1. pull Station - There should only be one pull station for each a b c d building since this is not a evacuation system' Sheet 3 of 5 1350 Broad Street General File - Fire Alarm for Marigold Center PC# 97-O25.pc1 2. HVAC Duct Detection - provide an LED display for each HVAC unit showing the status of the smoke detector. lnclude testing and alarm verification. 3. Class-1 Hood - provide monitoring for each hoods suppression system. tnclude Separate zone if more than one business' Ok to place several hoods at the same business on one zone if necessary. 4.WaterFlow-Thereshouldonlybeonepullstationforeach building' S. PIV Timper - Each valve tamper shall be a separate zone indicating which building it serves' 6. Smoke/Heat Detection - Zone by building' 7. Area separation walls - smokes are used for door hold open and are "uriently proposed for the one-hour area separation wall at sav-on Drug' and will release roll down doors. lf used in conjunction *itn the required area separation wall (for the High Rack storage areas) they shall be on a separate zone. lf used in just to hold open doors not in conjunction with an area separation wall they may be on the same zone as smoke/Heat Detection' 5. os&Y - Tamper alarms shall be identified as a separate zone' Graphic Annunciator Panel / Remote Panel - Remote annunciator panels shall meet the requirements of UFC Section 1007.3'3.7a and shall be electrically supervised. IUFC 1007.3'3.7.11 13) Acceotance Test and Certification - a. Acceptance Test - Upon completion of the installation, a satisfactory test of the entire system shall be made in the presence oJ the chief' All functions of the system or alteration shall be tested. IUFC 1OO7'3'4'1) b. Certification - The permittee shall provide the NFPA Certification of the Compliance to the chief that the system has been installed in accordance with the approved plans and specifications. tuFC 1007 '3'4'21 lnstructions - When required by the chief, operating, testing and maintenance instructions and "as-built" drawings and equipment specification s shall be provided at an approved locations' tUFC 1007.3,4.31 12l, c 15) Sheet 4 of 5 1350 Broad Street General File - Fire Alarm for Marigold Center PC# 97-O25.Pc1 14l,provide a written description or matrix chart to define the events which occur when various initiating devices are activated. The description should include details relating to annunciation, evacuation warning, remote signaling and activation of fire safety control functions, as applicable' Part 3 of Title 24 CCR, The California Electrical Code (CEC) limits the amount of conduit fill to a maximum of 4Oo/o. Chapter 9 or Part 3 provides tables indicating the maximum number of conductors of various sizes which can be used in various sizes of conduit in order to comply with the 40% limitation. Sh.ow the size of conduit and the percentage of conduit file. lnclude caiculations for review and approval or table number from NEC. 16) Show the following administrative 1001.31: requirements on the plans t1994 UFC, lnstalling contractors name, address and phone number' Contractors license & local business license numbers' site address - 3950 Broad is the is the General File for the entire complex. Basis for system installation - Show the Building Code occupancy classification for each building' Building owner and tenant name (if already established). Location of all components, including end-of-line devices, if involved. 11994 UFC, 1001 .31 Symbol legend which includes quantity of devices, manufactures name, model, etc. t1994 UFC, 1001 .31 Description of zone assignments/device addresses. t1994 UFC, 1001'31 Provide a complete building cross section, include attic, soffit, or ceiling details with each individual building submittal. t1994 UFC, 1001'31 Specifications and details of through-penetration fire stopping, if required. [U.L. Fire Resistance Directories] Device mounting heights for manual boxes and visible notification appliances. TNFPA 72, 3-8.1.1,5-9.1.1 & 6-4.1.11 Primary power supply details. TNFPA 72, 1-5'2.4,'2'81 171 provide the signals/wording that will be received by the central station. 1g) Show the actual wording that will be used on the key pad. lnclude device name and address number' a. b. c. d. e. f. g. h. i. k t. -l Sheet 5 of 5 1350 Broad Street General File - Fire Alarm for Marigold Center PC# 97-O25.pc1 19) Missing PlV, water flow, and tamper for Building E. lnclude HVAC, and smoke release for doors. 2Ol Missing HVAC system for Building G. 21l' Missing class-l hoods (three total) for Carl's Jr., Building pad C. 221 Missing HVAC systems for Vons, Building A. 23!. lnclude information on how the batteries will be supervised at the separate power supply used for the horns at the pull stations. It appears as if the wiring for the horns is supervised by the module supplied in the Radionics panel. The batteries in the Radionics panel also appear to be supervised but not the aux. power supply. a a-\,