HomeMy WebLinkAboutItem 6d. Attachment B - 1166 Walnut TI Plans (Spec. 2000577-04)_High Resolution PlansPROJECT
SITE
H I G H W A Y 1 0 1
S
A
N
T
A
R
O
S
A
S
T
W A L N U T S T
1
NORTH ARROW
LEVEL
DESIGNATION
GRID REFERENCE
SECTION REFERENCE
VIEW SHEET LOCATION
REFERENCE SHEET LOCATION
VIEW NUMBER
VIEW TITLE
LEVEL
ELEVATION
BUILDING LEVELS
DETAIL REFERENCE
Name
0' - 0"
A101
1
SIM
A101
1
SIM
BUILDING ELEVATION
A101
1
SIM
A101
1
2
3
4
INTERIOR ELEVATIONS
DOOR W/CLOSER
DOOR TAG
WINDOW TAG
STOREFRONT TAG
WALL TAG
CENTERLINEREVISION TAG
A4
1i
01
101
View Name
SCALE: 1/8" = 1'-0"A-101 A-202
20
0
?P1
MATERIAL TAG
PROJECT DIRECTORY
PROJECT INFORMATION
VICINITY MAP
USE OF PLANS:THESE PLANS ARE THE PROPERTY OF RRM AND MAY NOT BE
USED WITHOUT THE EXPRESS, WRITTEN CONSENT.
THESE NOTES APPLY TO ALL PORTIONS, PHASES AND SUBCONTRACTORS OF
THIS PROJECT.
APPLICABLE CODES AND STANDARDS:
• 2022 CALIFORNIA BUILDING CODE AND ITS APPENDICES AND
STANDARDS.
• 2022 CALIFORNIA PLUMBING CODE AND ITS APPENDICES AND
STANDARDS.
• 2022 CALIFORNIA MECHANICAL CODE AND ITS APPENDICES AND
STANDARDS.
• 2022 CALIFORNIA FIRE CODE AND ITS APPENDICES AND STANDARDS.
• 2022 CALIFORNIA ELECTRICAL CODE AND ITS APPENDICES AND
STANDARDS.
• 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS.
• 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE AND ITS
APPENDICIES AND STANDARDS.
• CURRENT CITY OF SAN LUIS OBISPO MUNICIPAL CODE.
1. ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR
DIMENSION, GRADE, EXTENT AND COMPATIBILITY WITH EXISTING SITE
CONDITIONS. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT
AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS
SHALL BE BROUGHT TO THE ARCHITECT’S ATTENTION IMMEDIATELY. DO NOT
PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL
SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO
DO SO, HE/SHE SHALL BE PRECEDING AT HIS/HER OWN RISK.
2. DIMENSIONS SHOWN SHALL TAKE PRECEDENCE OVER DRAWING SCALE OR
PROPORTION. LARGER SCALE DRAWINGS SHALL TAKE PRECEDENCE OVER
SMALLER SCALE DRAWINGS. ALL DIMENSIONS ARE ROUGH AND TO FACE OF
FRAMING.
3. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS
REQUIREMENTS AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL
COMPLY WITH ALL LOCAL ORDINANCES.
4. CONTRACTOR IS TO BE RESPONSIBLE FOR BEING FAMILIAR WITH THESE
DOCUMENTS INCLUDING ALL CONTRACT REQUIREMENTS.
5. CONTRACTOR TO REVIEW CALIFORNIA GREEN CODE REQUIREMENTS FOR
CONTRACTOR REQUIREMENTS.
6. TEMPORARY FACILITIES: CONTRACTOR SHALL PAY FOR, PROVIDE AND
MAINTAIN TEMPORARY FACILITIES FOR PROJECT PROTECTION AND
CONSTRUCTION, AND AS REQUIRED BY LOCAL REGULATION AND THESE
DOCUMENTS. SUCH FACILITIES INCLUDE, BUT ARE NOT LIMITED TO: TOILETS,
LIGHTS, HEATERS, POWER, GAS, FANS, WATER, PHONES, FENCES, SIGNS,
SHEDS, ETC. REMOVE FROM SITE UPON COMPLETION OF WORK. OBTAIN
BUILDING OFFICIAL OR FIRE MARTIAL APPROVAL PRIOR TO USE OF ANY
TEMPORARY HEATING DEVICE.
7. CONTRACTOR SHALL PROVIDE FOR PROTECTION AND SAFETY:
RESPONSIBLE FOR ALL ITEMS (SIGNS, LIGHTS, FENCES, BRACING, ANCHOR-
AGE, FIRE-EXTINGUISHERS, ETC.) NECESSARY FOR THE PROTECTION OF
THE PUBLIC, WORKERS, MATERIALS, CONSTRUCTION AND PROPERTY PER
LOCAL, STATE AND FEDERAL REQUIREMENTS (INCLUDING EARTHQUAKES,
FIRES, SPILLS, ACCIDENTS, EROSION, MUD, DUST, ETC.).
PROJECT GENERAL NOTES
PROJECT SCOPE:
1.
2.
SELECTIVE DEMOLITION OF PARTITIONS, CEILINGS, FINISHES,
MECHANICAL EQUIPMENT, ELECTRICAL DEVICES.
CONSTRUCTION OF NEW PARTITIONS, CEILINGS, FINISHES, MECHANICAL
EQUIPMENT, ELECTRICAL DEVICES, INTERIOR STOREFRONT WINDOWS.
BUILDING INFORMATION:
OCCUPANCY: B, A-3
CONSTRUCTION TYPE: VB
FIRE SPRINKLERED: YES
BUILDING HEIGHT: 35'
NUMBER OF STORIES: 2
TOTAL BUILDING AREA: 10,921 SF
FIRST FLOOR BUILDING AREA: 5,586 SF
SECOND FLOOR BUILDING AREA: 5,335 SF
SEE SHEET G-401 FOR CODE ANALYSIS
SITE INFORMATION:
APN:
STREET ADDRESS:
ZONING:
LOT SIZE:
LAND USE:
EXISTING USE:
PROPOSED USE:
1106 WALNUT ST. SAN LUIS OBISPO, CA.
001-207-039
O (OFFICE)
OFFICE
OFFICE
0.87 AC
OFFICE
ADDRESS:
CONTACT:
EMAIL:
CITY OF SAN LUIS OBISPO
919 PALM ST.
SAN LUIS OBISPO, CA. 93401
OWNER
SANDRA GOLONKA
SGOLONKA@SLOCITY.ORG
ADDRESS:
CONTACT:
EMAIL:
RRM DESIGN GROUP
3765 S. HIGUERA ST. SUITE 102
SAN LUIS OBISPO, CA. 93401
ARCHITECT
JON HOUCK
JHOUCK@RRMDESIGN.COM
ADDRESS:
CONTACT:
EMAIL:
3C ENGINEERING
1500 PALM ST.
SAN LUIS OBISPO, CA. 93401
MECHANICAL
ENGINEER
DENVER STANGER
DSTANGER@3CENG.COM
ADDRESS:
CONTACT:
EMAIL:
THOMA ELECTRIC
3562 EMPLEO ST.
SAN LUIS OBISPO, CA. 93401
ELECTRICAL
ENGINEER
CHRIS JOSE
CJOSE@THOMAELEC.COM
HC HOLLOW CORE
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HVAC HEATING, VENTILATION, A/C
ID INSIDE DIAMETER
IIC IMPACT INSULATION CLASS
IN INCH
INCAND INCANDESCENT
INSUL INSULATION, INSULATED
INT INTERIOR
JC JANITORS CLOSET
JT JOINT
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LEED LEADERSHIP IN ENERGY AND
ENVIRONMENTAL DESIGN
LF LINEAR FEET
LIN LINEN CLOSET
LINO LINOLEUM
LT(G) LIGHT(ING)
LVL LAMINATED VENEER LUMBER
LVT LUXURY VINYL TILE
LW LIGHTWEIGHT
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O.P. OVERFLOW PIPE
OC ON CENTER
OD OVERFLOW DRAIN
OFF OFFICE
OH OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
(P) PROPOSED
PERM PERIMETER
PERP PERPENDICULAR
PG PAINT GRADE
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PP POWER POLE
PR PAIR
PRTN PARTITION
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT PRESSURE TREATED
PTD PAINTED
PV PHOTO VOLTAIC
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
QTY QUANTITY
R RADIUS, RISER
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT (MECH)
S SOUTH
SAFB SOUND ATTENUATION FIBER BATT
SAWP SELF ADHEREING WATERPROOFING
SC SCUPPER/SOLID CORE
SCHED SCHEDULE
SEAL SEALANT
SECT SECTION
SF SQUARE FOOT
SHT SHEET
SHTHG SHEATHING
SIM SIMILAR
SM SHEET METAL
SPEC SPECIFICATION
SQ SQURE
SS SOLID SURFACE
SSTL STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUPSPENDED
SV SHEET VINYL
SYM SYMMMETRICAL
T TREAD
T&G TONGUE & GROOVE
TEL TELEPHONE
TEMP TEMPERED
TER TERRAZZO
THK THICK
THR THRESHOLD
TJI TRUSS JOIST I-JOIST
TO TOP OF
TOS TOP OF SLAB
TOW TOP OF WALL
TRANS TRANSFORMER
TV TELEVISION
TYP TYPICAL
UFAS UNIFORM FEDERAL ACCESSIBILITY
STANDARDS
UG UNDERGROUND
UNFIN UNFINISHED
UNO ULNESS NOTED OTHERWISE
UV UTRAVIOLET
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VENT TERMINATION PIPE
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/D WASHER DRYER
W/O WITHOUT
WC WATERCLOSET
WD WOOD
WDW WINDOW
WH WATER HEATER
WI WROUGHT IRON
WIN WINDOW
WP WATERPROOF(ING)
WR WEATHER RESISTIVE
WRB WATER RESISTIVE BARRIER
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
YD YARD
ABBREVIATIONS SYMBOLS
A/C AIR CONDITIONING
ABV ABOVE
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
AFCI ARC FAULT CIRCUIT INTERRUPTER
AFF ABOVE FINISH FLOOR
AL ALUMINUM
ALT ALTERNATE
ARCH ARCHITECT(URAL)
BD BOARD
BDRM BEDROOM
BET BETWEEN
BIT BITUMINOUS
BLDG BUILDNG
BLKG BLOCKING
BLW BELOW
BM BEAM
BOT BOTTOM
BUR BUILT UP ROOF
CB CATCH BASIN
CBC CALIFORNIA BUILDING CODE
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
DBL DOUBLE
DF DRINKING FOUNTAIN
DIA DIAMETER, DIAPHRAGM
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWN SPOUT
DTL DETAIL
DW DISHWASHER
DWG DRAWING
(E) EXISTING
E EAST
EA EACH
EJ EXPANSION JOINT
EL,
ELEV
ELEVATION
ELEC ELECTRIC
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
EXH EXHAUST
EXP EXPANSION
EXT EXTERIOR
FACP FIRE ALARM CONTROL PANEL
FAU FORCED AIR UNIT
FAWP FLUID APPLIED WATERPROOFING
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR ELEVATION
FG FINISHED GRADE
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FLUOR FLOURESCENT
FND FOUNDATION
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOIC FURNISHED BY OWNER INSTALLED BY
CONTRACTOR
FOM FACE OF MASONRY
FOS FACE OF STUD
FRP FIBERGLASS REINFORCED PANELS
FT FOOT OR FEET
FTG FOOTING
GA GAUGE, GAGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GWB GYPSUM BOARD
GYP GYPSUM
HB HOSE BIBB
GENERAL
G-001 TITLE SHEET
G-203 CAL GREEN REQUIREMENTS
G-204 CAL GREEN REQUIREMENTS
G-205 CAL GREEN REQUIREMENTS
G-401 CODE ANALYSIS
G-902 ACCESSIBILITY DETAILS
G-903 ACCESSIBILITY DETAILS
G-904 ACCESSIBILITY DETAILS
8
ARCHITECTURAL SITE
AS-101 ARCHITECTURAL SITE PLAN
1
ARCHITECTURAL
AD-101 DEMOLITION FIRST FLOOR PLAN
AD-102 DEMOLITION SECOND FLOOR PLAN
AD-111 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR
AD-112 DEMOLITION REFLECTED CEILING PLAN - SECOND FLOOR
A-101 PROPOSED FIRST FLOOR PLAN
A-102 PROPOSED SECOND FLOOR PLAN
A-111 REFLECTED CEILING PLAN - FIRST FLOOR
A-112 REFLECTED CEILING PLAN - SECOND FLOOR
A-120 ROOF PLAN
A-200 EXTERIOR ELEVATIONS
A-401 ENLARGED FLOOR PLANS
A-411 INTERIOR ELEVATIONS
A-412 INTERIOR ELEVATIONS
A-413 INTERIOR ELEVATIONS
A-501 FIRST FLOOR FINISH PLAN
A-502 SECOND FLOOR FINISH PLAN
A-503 FIRST FLOOR FURNITURE PLAN
A-504 SECOND FLOOR FURNITURE PLAN
A-601 DOOR AND WINDOW SCHEDULES
A-901 DOOR & WINDOW DETAILS
A-902 DETAILS
A-903 DETAILS
A-904 DETAILS
23
MECHANICAL & PLUMBING
MP-000 MECHANICAL & PLUMBING GENERAL NOTES
MP-001 MECHANICAL & PLUMBING SCHEDULES
MP-002 MECHANICAL AND PLUMBING DETAILS
EC-000 ENERGY COMPLIANCE DOCUMENTATION
MPD-101 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN
MPD-102 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN
MP-200 MECHANICAL & PLUMBING FIRST FLOOR PLAN
MP-300 MECHANICAL & PLUMBING SECOND FLOOR PLAN
8
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES
E-002 ELECTRICAL LEGEND AND ABBREVIATIONS
E-003 ELECTRICAL SINGLE LINE DIAGRAM AND SCHEDULES
ED-101 FIRST FLOOR POWER SIGNAL DEMOLITION FIRST FLOOR PLAN
ED-102 SECOND FLOOR POWER SIGNAL DEMOLITION PLAN
E-101 FIRST FLOOR POWER AND SIGNAL PLAN
E-102 SECOND FLOOR POWER AND SIGNAL PLAN
E-111 FIRST FLOOR LIGHTING PLAN
E-112 SECOND FLOOR LIGHTING PLAN
E-113 LIGHTING EMERGENCY PHOTOMETRIC PLANS
E-121 ELECTRICAL ROOF PLAN
E-201 ELECTRICAL DETAILS
E-301 TITLE 24 ENERGY FORMS - INTERIOR LIGHTING
13
Grand total: 53
1
1. FIRE SPRINKLER MODIFICATIONS DUE TO ADDING / MOVING WALLS
DEFERRED SUBMITTALS1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
No. C 79870
B R I A N A .NEL
S
O
N
C I V I L
R
E
GISTERE D P R OFESSIO
N
A
LE
N
G
I
N
E
ER
S
TAT
EOFCA L I F O RNIA
1106 WALNUT
TENANT IMPROVEMENT
sheet no.description
SAN LUIS OBISPO COUNTY, CALIFORNIA
APPROVED BY
SPECIFICATION NO.DATE SHEET
Brian A. Nelson, City Engineer R.C.E. C79870 Approved Date
FILE NO./LOCATION
index to plans
2000577-04 09/12/2024 G-001
9/13/24
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
CA
L
G
R
E
E
N
R
E
Q
U
I
R
E
M
E
N
T
S
G-203
JH
JR
6/20/24
JR
ALLOWABLE RATING
TABLE 5.106.8 [N] -
MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT AND GLARE (BUG) RATING1, 2
LUMINAIRE GREATER THAN 2
MOUNTING HEIGHTS (MH) FROM
PROPERTY LINE
MAXIMUM ALLOWABLE
BACKLIGHT RATING3 (B)
LIGHTING
ZONE LZ4
NO LIMIT
LUMINAIRE BACK HEMISPHERE
IS 1-2 MH FROM PROPERTY LINE
LUMINAIRE BACK HEMISPHERE
IS 0.5-1 MH FROM PROPERTY
LINE
LUMINAIRE BACK HEMISPHERE
IS LESS THAN 0.5 MH FROM
PROPERTY LINE
NO LIMITNO LIMITNO LIMITN/A
FOR AREA LIGHTING3
MAXIMUM ALLOWABLE
UPLIGHT RATING (U)
FOR ALL OTHER OUTDOOR
LIGHTING, INCLUDING
DECORATIVE LUMINAIRES
MAXIMUM ALLOWABLE
GLARE RATING (G)
LUMINAIRE GREATER THAN 2
MOUNTING HEIGHTS (MH) FROM
PROPERTY LINE
LUMINAIRE FRONT HEMISPHERE
IS 1-2 MH FROM PROPERTY LINE
LIGHTING
ZONE LZ3
LIGHTING
ZONE LZ2
LIGHTING
ZONE LZ1
LIGHTING
ZONE LZ0
B4B4B3B2N/A
B3B3B2B1N/A
B2B1B0B0N/A
U0U0U0U0N/A
U4U3U2U1N/A
G4G3G2G1N/A
G2G1G1G0N/A
LUMINAIRE FRONT HEMISPHERE
IS 0.5-1 MH FROM PROPERTY
LINE
LUMINAIRE FRONT HEMISPHERE
IS LESS THAN 0.5 MH FROM
PROPERTY LINE
G1G1G0G0N/A
G1G0G0G0N/A
TOTAL NUMBER OF
ACTUAL PARKING
SPACES
TABLE 5.106.5.3.1
0-9
10-25
26-50
51-75
76-100
101-150
NUMBER OF EVCS
(EV CAPABLE SPACES
PROVIDED WITH EVSE) 2
151-200
201 AND OVER
NUMBER OF REQUIRED
EV CAPABLE SPACES
0
4
8
13
17
25
35
20% OF TOTAL 1
0
0
2
3
4
6
6
25% OF EV CAPABLE
SPACES 1
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
NONRESIDENTIAL MANDATORY MEASURES, SHEET 1 (JANUARY 2023)
DIVISION 5.1 PLANNING AND DESIGN
5.106 SITE DEVELOPMENT
5.106.1 STORMWATER POLLUTION FOR PROJECTS THAT DISTURB LESS THAN
ONE ACRE OF LAND
NEWLY CONSTRUCTED PROJECTS AND ADDITIONS WHICH DISTURB LESS
THAN ONE ACRE OF LAND AND ARE NOT PART OF A LARGER COMMON PLAN
OF DEVELOPMENT OR SALE SHALL PREVENT THE POLLUTION OF
STORMWATER RUNOFF FROM THE CONSTRUCTION ACTIVITIES THROUGH
ONE OR MORE OF THE FOLLOWING MEASURES:
5.106.1.1 LOCAL ORDINANCE
COMPLY WITH A LAWFULLY ENACTED STORMWATER MANAGEMENT AND/OR
EROSION CONTROL ORDINANCE.
5.106.1.2 BEST MANAGEMENT PRACTICES (BMP’S)
PREVENT THE LOSS OF SOIL THROUGH WIND OR WATER EROSION BY
IMPLEMENTING AN EFFECTIVE COMBINATION OF EROSION AND SEDIMENT
CONTROL AND GOOD HOUSEKEEPING BMP’S.
1. SOIL LOSS BMP’S THAT SHOULD BE CONSIDERED FOR IMPLEMENTATION
AS APPROPRIATE FOR EACH PROJECT INCLUDE, BUT ARE NOT LIMITED
TO, THE FOLLOWING:
a. SCHEDULING CONSTRUCTION ACTIVITY DURING DRY WEATHER,
WHEN POSSIBLE.
b. PRESERVATION OF NATURAL FEATURES, VEGETATION, SOIL AND
BUFFERS AROUND SURFACE WATERS.
c. DRAINAGE SWALES OR LINED DITCHES TO CONTROL
STORMWATER FLOW.
d. MULCHING OR HYDROSEEDING TO STABILIZE DISTURBED SOILS.
e. EROSION CONTROL TO PROTECT SLOPES.
f. PROTECTION OF STORM DRAIN INLETS (GRAVEL BAGS OR
CATCH BASIN INSERTS).
g. PERIMETER SEDIMENT CONTROL (PERIMETER SILT FENCE, FIBER
ROLLS).
h. SEDIMENT TRAP OR SEDIMENT BASIN TO RETAIN SEDIMENT ON
SITE.
i. STABILIZED CONSTRUCTION EXITS.
j. WIND EROSION CONTROL.
k. OTHER SOIL LOSS BMP'S ACCEPTABLE TO THE ENFORCING
AGENCY.
2.GOOD HOUSEKEEPING BMP’S TO MANAGE CONSTRUCTION EQUIPMENT,
MATERIALS, NON-STORMWATER DISCHARGES, AND WASTES THAT
SHOULD BE CONSIDERED FOR IMPLEMENTATION AS APPROPRIATE FOR
EACH PROJECT INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:
a. DEWATERING ACTIVITIES.
b. MATERIAL HANDLING AND WASTE MANAGEMENT.
c. BUILDING MATERIALS STOCKPILE MANAGEMENT.
d. MANAGEMENT OF WASHOUT AREAS (CONCRETE, PAINTS,
STUCCO, ETC.).
e. CONTROL OF VEHICLE/EQUIPMENT FUELING TO CONTRACTOR'S
STAGING AREA.
f. VEHICLE AND EQUIPMENT CLEANING PERFORMED OFF SITE.
g. SPILL PREVENTION AND CONTROL.
h. OTHER HOUSEKEEPING BMP'S ACCEPTABLE TO THE ENFORCING
AGENCY.
5.106.4 BICYCLE PARKING
FOR BUILDINGS WITHIN THE AUTHORITY OF CALIFORNIA BUILDING
STANDARDS COMMISSION AS SPECIFIED IN SECTION 103, COMPLY WITH
SECTION 5.106.4.1. FOR BUILDINGS WITHIN THE AUTHORITY OF THE DIVISION
OF THE STATE ARCHITECT PURSUANT TO SECTION 105, COMPLY WITH
SECTION 5.106.4.2.
5.106.4.1 BICYCLE PARKING [BSC-CG]
COMPLY WITH SECTIONS 5.106.4.1.1 AND 5.106.4.1.2;OR MEET THE
APPLICABLE LOCAL ORDINANCE, WHICHEVER IS STRICTER.
5.106.4.1.1 SHORT-TERM BICYCLE PARKING
IF THE NEW PROJECT OR AN ADDITION OR ALTERATION IS ANTICIPATED
TO GENERATE VISITOR TRAFFIC, PROVIDE PERMANENTLY ANCHORED
BICYCLE RACKS WITHIN 200 FEET OF THE VISITORS' ENTRANCE, READILY
VISIBLE TO PASSERS-BY, FOR 5 PERCENT OF NEW VISITOR MOTORIZED
VEHICLE PARKING SPACES BEING ADDED, WITH A MINIMUM OF ONE
TWO-BIKE CAPACITY RACK.
1 CALCULATION FOR SPACES SHALL BE ROUNDED UP TO THE NEAREST
WHOLE NUMBER.
CHAPTER 1 - ADMINISTRATION
SECTION 101 GENERAL
101.1 TITLE.
THESE REGULATIONS SHALL BE KNOWN AS THE CALIFORNIA GREEN
BUILDING STANDARDS CODE AND MAY BE CITED AS SUCH AND WILL BE
REFERRED TO HEREIN AS “THIS CODE.”IT IS INTENDED THAT IT SHALL ALSO
BE KNOWN AS THE CALGREEN CODE. THE CALIFORNIA GREEN BUILDING
STANDARDS CODE IS PART 11 OF THIRTEEN PARTS OF THE OFFICIAL
COMPILATION AND PUBLICATION OF THE ADOPTION, AMENDMENT AND
REPEAL OF BUILDING REGULATIONS TO THE CALIFORNIA CODE OF
REGULATIONS, TITLE 24, ALSO REFERRED TO AS THE CALIFORNIA BUILDING
STANDARDS CODE.
101.2 PURPOSE.
THE PURPOSE OF THIS CODE IS TO IMPROVE PUBLIC HEALTH, SAFETY AND
GENERAL WELFARE BY ENHANCING THE DESIGN AND CONSTRUCTION OF
BUILDINGS THROUGH THE USE OF BUILDING CONCEPTS HAVING A REDUCED
NEGATIVE IMPACT OR POSITIVE ENVIRONMENTAL IMPACT AND
ENCOURAGING SUSTAINABLE CONSTRUCTION PRACTICES IN THE
FOLLOWING CATEGORIES:
1. PLANNING AND DESIGN.
2. ENERGY EFFICIENCY.
3. WATER EFFICIENCY AND CONSERVATION.
4. MATERIAL CONSERVATION AND RESOURCE EFFICIENCY.
5. ENVIRONMENTAL QUALITY.
101.3 SCOPE.
THE PROVISIONS OF THIS CODE SHALL APPLY TO THE PLANNING, DESIGN,
OPERATION, CONSTRUCTION, USE AND OCCUPANCY OF EVERY NEWLY
CONSTRUCTED BUILDING OR STRUCTURE, UNLESS OTHERWISE INDICATED
IN THIS CODE, THROUGHOUT THE STATE OF CALIFORNIA.
IT IS NOT THE INTENT THAT THIS CODE SUBSTITUTE OR BE IDENTIFIED AS
MEETING THE CERTIFICATION REQUIREMENTS OF ANY GREEN BUILDING
PROGRAM.
SECTION 301 GENERAL
301.1 SCOPE.
BUILDINGS SHALL BE DESIGNED TO INCLUDE THE GREEN BUILDING
MEASURES SPECIFIED AS MANDATORY IN THE APPLICATION CHECKLISTS
CONTAINED IN THIS CODE. VOLUNTARY GREEN BUILDING MEASURES ARE
ALSO INCLUDED IN THE APPLICATION CHECKLISTS AND MAY BE INCLUDED IN
THE DESIGN AND CONSTRUCTION OF STRUCTURES COVERED BY THIS
CODE, BUT ARE NOT REQUIRED UNLESS ADOPTED BY A CITY, COUNTY, OR
CITY AND COUNTY AS SPECIFIED IN SECTION 101.7.
301.3 NONRESIDENTIAL ADDITIONS AND ALTERATIONS
[BSC-CG]THE PROVISIONS OF INDIVIDUAL SECTIONS OF CHAPTER 5 APPLY
TO NEWLY CONSTRUCTED BUILDINGS, BUILDING ADDITIONS OF 1,000
SQUARE FEET OR GREATER, AND/OR BUILDING ALTERATIONS WITH A
PERMIT VALUATION OF $200,000 OR ABOVE (FOR OCCUPANCIES WITHIN THE
AUTHORITY OF CALIFORNIA BUILDING STANDARDS COMMISSION). CODE
SECTIONS RELEVANT TO ADDITIONS AND ALTERATIONS SHALL ONLY APPLY
TO THE PORTIONS OF THE BUILDING BEING ADDED OR ALTERED WITHIN THE
SCOPE OF THE PERMITTED WORK.
A CODE SECTION WILL BE DESIGNATED BY A BANNER TO INDICATE WHERE
THE CODE SECTION ONLY APPLIES TO NEWLY CONSTRUCTED BUILDINGS [N]
OR TO ADDITIONS AND/OR ALTERATIONS [A]. WHEN THE CODE SECTION
APPLIES TO BOTH, NO BANNER WILL BE USED.
301.3.1 NONRESIDENTIAL ADDITIONS AND ALTERATIONS THAT CAUSE
UPDATES TO PLUMBING FIXTURES ONLY:
NOTE: ON AND AFTER JANUARY 1, 2014, CERTAIN COMMERCIAL REAL
PROPERTY, AS DEFINED IN CIVIL CODE SECTION 1101.3, SHALL HAVE ITS
NONCOMPLIANT PLUMBING FIXTURES REPLACED WITH APPROPRIATE
WATER-CONSERVING PLUMBING FIXTURES UNDER SPECIFIC
CIRCUMSTANCES. SEE CIVIL CODE SECTION 1101.1 ET SEQ.FOR
DEFINITIONS, TYPES OF COMMERCIAL REAL PROPERTY AFFECTED,
EFFECTIVE DATES, CIRCUMSTANCES NECESSITATING REPLACEMENT OF
NONCOMPLIANT PLUMBING FIXTURES, AND DUTIES AND
RESPONSIBILITIES FOR ENSURING COMPLIANCE.
301.3.2 WASTE DIVERSION
THE REQUIREMENTS OF SECTION 5.408 SHALL BE REQUIRED FOR
ADDITIONS AND ALTERATIONS WHENEVER A PERMIT IS REQUIRED FOR
WORK.
301.4 PUBLIC SCHOOLS AND COMMUNITY COLLEGES (SEE GBSC)
301.5 HEALTH FACILITIES (SEE GBSC)
SECTION 102 CONSTRUCTION
DOCUMENTS AND INSTALLATION
VERIFICATION
102.1 SUBMITTAL DOCUMENTS.
CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL BE SUBMITTED IN
ONE OR MORE SETS WITH EACH APPLICATION FOR A PERMIT. WHERE
SPECIAL CONDITIONS EXIST, THE ENFORCING AGENCY IS AUTHORIZED TO
REQUIRE ADDITIONAL CONSTRUCTION DOCUMENTS TO BE PREPARED BY A
LICENSED DESIGN PROFESSIONAL AND MAY BE SUBMITTED SEPARATELY.
EXCEPTION:THE ENFORCING AGENCY IS AUTHORIZED TO WAIVE THE
SUBMISSION OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT
REQUIRED TO BE PREPARED BY A LICENSED DESIGN PROFESSIONAL.
102.2 INFORMATION ON CONSTRUCTION DOCUMENTS.
CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO
INDICATE THE LOCATION, NATURE AND SCOPE OF THE PROPOSED GREEN
BUILDING FEATURE AND SHOW THAT IT WILL CONFORM TO THE PROVISIONS
OF THIS CODE, THE CALIFORNIA BUILDING STANDARDS CODE AND OTHER
RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS AS DETERMINED
BY THE ENFORCING AGENCY.
102.3 VERIFICATION.
DOCUMENTATION OF CONFORMANCE FOR APPLICABLE GREEN BUILDING
MEASURES SHALL BE PROVIDED TO THE ENFORCING AGENCY. ALTERNATE
METHODS OF DOCUMENTATION SHALL BE ACCEPTABLE WHEN THE
ENFORCING AGENCY FINDS THAT THE PROPOSED ALTERNATE
DOCUMENTATION IS SATISFACTORY TO DEMONSTRATE SUBSTANTIAL
CONFORMANCE WITH THE INTENT OF THE PROPOSED GREEN BUILDING
MEASURE.
CHAPTER 3 - GREEN BUILDING
CHAPTER 5 - NONRESIDENTIAL
MANDATORY MEASURES
5.106.5.3.2 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)
EV CAPABLE SPACES SHALL BE PROVIDED WITH EVSE TO CREATE EVCS IN
THE NUMBER INDICATED IN TABLE 5.106.5.3.1. THE EVCS REQUIRED BY
TABLE 5.106.5.3.1 MAY BE PROVIDED WITH EVSE IN ANY COMBINATION OF
LEVEL 2 AND DIRECT CURRENT FAST CHARGING (DCFC), EXCEPT THAT AT
LEAST ONE LEVEL 2 EVSE SHALL BE PROVIDED.
ONE EV CHARGER WITH MULTIPLE CONNECTORS CAPABLE OF CHARGING
MULTIPLE EVS SIMULTANEOUSLY SHALL BE PERMITTED IF THE
ELECTRICAL LOAD CAPACITY REQUIRED BY SECTION 5.106.5.3.1 FOR EACH
EV CAPABLE SPACE IS ACCUMULATIVELY SUPPLIED TO THE EV CHARGER.
THE INSTALLATION OF EACH DCFC EVSE SHALL BE PERMITTED TO
REDUCE THE MINIMUM NUMBER OF REQUIRED EV CAPABLE SPACES
WITHOUT EVSE BY FIVE AND REDUCE PROPORTIONALLY THE REQUIRED
ELECTRICAL LOAD CAPACITY TO THE SERVICE PANEL OR SUBPANEL.
5.106.5.3.3 USE OF AUTOMATIC LOAD MANAGEMENT SYSTEMS (ALMS)
ALMS SHALL BE PERMITTED FOR EVCS. WHEN ALMS IS INSTALLED, THE
REQUIRED ELECTRICAL LOAD CAPACITY SPECIFIED IN SECTION 5.106.5.3.1
FOR EACH EVCS MAY BE REDUCED WHEN SERVICED BY AN EVSE
CONTROLLED BY AN ALMS. EACH EVSE CONTROLLED BY AN ALMS SHALL
DELIVER A MINIMUM 30 AMPERES TO AN EV WHEN CHARGING ONE
VEHICLE AND SHALL DELIVER A MINIMUM 3.3 KW WHILE SIMULTANEOUSLY
CHARGING MULTIPLE EVS.
5.106.5.3.4 ACCESSIBLE EVCS
WHEN EVSE IS INSTALLED, ACCESSIBLE EVCS SHALL BE PROVIDED IN
ACCORDANCE WITH THE CALIFORNIA BUILDING CODE, CHAPTER 11B,
SECTION 11B-228.3.
NOTE: FOR EVCS SIGNS, REFER TO CALTRANS TRAFFIC OPERATIONS
POLICY DIRECTIVE 13-01 (ZERO EMISSION VEHICLE SIGNS AND PAVEMENT
MARKINGS) OR ITS SUCCESSOR(S).
5.106.8 LIGHT POLLUTION REDUCTION [N].
OUTDOOR LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED TO COMPLY
WITH THE FOLLOWING:
1. THE MINIMUM REQUIREMENTS IN THE CALIFORNIA ENERGY CODE FOR
LIGHTING ZONES 0-4 AS DEFINED IN CHAPTER 10, SECTION 10-114 OF THE
CALIFORNIA ADMINISTRATIVE CODE; AND
2. BACKLIGHT (B) RATINGS AS DEFINED IN IES TM-15-11 (SHOWN IN TABLE A-1
IN CHAPTER 8);
3. UPLIGHT AND GLARE RATINGS AS DEFINED IN CALIFORNIA ENERGY CODE
(SHOWN IN TABLES 130.2-A AND 130.2-B IN CHAPTER 8) AND
4. ALLOWABLE BUG RATINGS NOT EXCEEDING THOSE SHOWN IN TABLE
5.106.8 [N],
OR COMPLY WITH A LOCAL ORDINANCE LAWFULLY ENACTED PURSUANT TO
SECTION 101.7, WHICHEVER IS MORE STRINGENT.
EXCEPTIONS: [N]
1. LUMINAIRES THAT QUALIFY AS EXCEPTIONS IN SECTION 130.2(B) AND 140.7
OF THE CALIFORNIA ENERGY CODE
2. EMERGENCY LIGHTING.
3. BUILDING FACADE MEETING THE REQUIREMENTS IN TABLE 140.7-B OF THE
CALIFORNIA ENERGY CODE, PART 6.
4. CUSTOM LIGHTING FEATURES AS ALLOWED BY THE LOCAL ENFORCING
AGENCY, AS PERMITTED BY SECTION 101.8 ALTERNATE MATERIALS,
DESIGNS AND METHODS OF CONSTRUCTION.
5. LUMINAIRES WITH LESS THAN 6,200 INITIAL LUMINAIRE LUMENS.
NOTES: [N]
1. SEE ALSO CALIFORNIA BUILDING CODE, CHAPTER 12, SECTION 1205.7 FOR
COLLEGE CAMPUS LIGHTING REQUIREMENTS FOR PARKING FACILITIES
AND WALKWAYS.
2. REFER TO CHAPTER 8 (COMPLIANCE FORMS, WORKSHEETS AND
REFERENCE MATERIAL) FOR IES TM-15-11 TABLE A1, CALIFORNIA ENERGY
CODE TABLES 130.2-A AND 130.2-B.
3. REFER TO THE CALIFORNIA ENERGY CODE FOR REQUIREMENTS FOR
ADDITIONS AND ALTERATIONS.
EXCEPTION:ADDITIONS OR ALTERATIONS WHICH ADD NINE OR LESS
VISITOR VEHICULAR PARKING SPACES.
5.106.4.1.2 LONG-TERM BICYCLE PARKING
FOR NEW BUILDINGS WITH TENANT SPACES THAT HAVE 10 OR MORE
TENANT-OCCUPANTS, PROVIDE SECURE BICYCLE PARKING FOR 5
PERCENT OF THE TENANT-OCCUPANT VEHICULAR PARKING SPACES
WITH A MINIMUM OF ONE BICYCLE PARKING FACILITY.
5.106.4.1.3
FOR ADDITIONS OR ALTERATIONS THAT ADD 10 OR MORE TENANT-
OCCUPANT VEHICULAR PARKING SPACES, PROVIDE SECURE BICYCLE
PARKING FOR 5 PERCENT OF THE TENANT VEHICULAR PARKING SPACES
BEING ADDED, WITH A MINIMUM OF ONE BICYCLE PARKING FACILITY.
5.106.4.1.4
FOR NEW SHELL BUILDINGS IN PHASED PROJECTS PROVIDE SECURE
BICYCLE PARKING FOR 5 PERCENT OF THE ANTICIPATED TENANT-
OCCUPANT VEHICULAR PARKING SPACES WITH A MINIMUM OF ONE
BICYCLE PARKING FACILITY.
5.106.4.1.5
ACCEPTABLE BICYCLE PARKING FACILITY FOR SECTIONS 5.106.4.1.2,
5.106.4.1.3, AND 5.106.4.1.4 SHALL BE CONVENIENT FROM THE STREET
AND SHALL MEET ONE OF THE FOLLOWING:
1. COVERED, LOCKABLE ENCLOSURES WITH PERMANENTLY
ANCHORED RACKS FOR BICYCLES;
2. LOCKABLE BICYCLE ROOMS WITH PERMANENTLY ANCHORED
RACKS; OR
3. LOCKABLE, PERMANENTLY ANCHORED BICYCLE LOCKERS.
NOTE:ADDITIONAL INFORMATION ON RECOMMENDED BICYCLE
ACCOMMODATIONS MAY BE OBTAINED FROM SACRAMENTO
AREA BICYCLE ADVOCATES.
5.106.4.2 BICYCLE PARKING [DSA]
FOR PUBLIC SCHOOLS AND COMMUNITY COLLEGES, COMPLY WITH
SECTIONS 5.106.4.2.1 AND 5.106.4.2.2.
5.106.4.2.1 STUDENT BICYCLE PARKING
PROVIDE PERMANENTLY ANCHORED BICYCLE RACKS CONVENIENTLY
ACCESSED WITH A MINIMUM OF FOUR TWO-BIKE CAPACITY RACKS PER
NEW BUILDING.
5.106.4.2.2 STAFF BICYCLE PARKING
PROVIDE PERMANENT, SECURE BICYCLE PARKING CONVENIENTLY
ACCESSED WITH A MINIMUM OF TWO STAFF BICYCLE PARKING SPACES
PER NEW BUILDING. ACCEPTABLE BICYCLE PARKING FACILITIES SHALL
BE CONVENIENT FROM THE STREET OR STAFF PARKING AREA AND
SHALL MEET ONE OF THE FOLLOWING:
1. COVERED, LOCKABLE ENCLOSURES WITH PERMANENTLY
ANCHORED RACKS FOR BICYCLES;
2. LOCKABLE BICYCLE ROOMS WITH PERMANENTLY ANCHORED
RACKS; OR
3. LOCKABLE, PERMANENTLY ANCHORED BICYCLE LOCKERS.
5.106.5.3 ELECTRIC VEHICLE (EV) CHARGING [N]
CONSTRUCTION TO PROVIDE ELECTRIC VEHICLE INFRASTRUCTURE AND
FACILITATE ELECTRIC VEHICLE CHARGING SHALL COMPLY W ITH SECTION
5.106.5.3.1 AND SHALL BE PROVIDED IN ACCORDANCE WITH REGULATIONS IN
THE CALIFORNIA BUILDING CODE AND THE CALIFORNIA ELECTRICAL CODE.
EXCEPTIONS:
1. ON A CASE-BY-CASE BASIS WHERE THE LOCAL ENFORCING AGENCY
HAS DETERMINED COMPLIANCE WITH THIS SECTION IS NOT FEASIBLE
BASED UPON ONE OF THE FOLLOWING CONDITIONS:
a. WHERE THERE IS NO LOCAL UTILITY POWER SUPPLY.
b. WHERE THE LOCAL UTILITY IS UNABLE TO SUPPLY ADEQUATE
POWER.
c. WHERE THERE IS EVIDENCE SUITABLE TO THE LOCAL
ENFORCEMENT AGENCY SUBSTANTIATING THAT ADDITIONAL LOCAL
UTILITY INFRASTRUCTURE DESIGN REQUIREMENTS, DIRECTLY
RELATED TO THE IMPLEMENTATION OF SECTION 5.106.5.3, MAY
ADVERSELY IMPACT THE CONSTRUCTION COST OF THE PROJECT.
2. PARKING SPACES ACCESSIBLE ONLY BY AUTOMATED MECHANICAL CAR
PARKING SYSTEMS ARE NOT REQUIRED TO COMPLY WITH THIS CODE
SECTION.
5.106.5.3.1 EV CAPABLE SPACES
EV CAPABLE SPACES SHALL BE PROVIDED IN ACCORDANCE WITH TABLE
5.106.5.3.1 AND THE FOLLOWING REQUIREMENTS:
1. RACEWAYS COMPLYING WITH THE CALIFORNIA ELECTRICAL CODE
AND NO LESS THAN 1-INCH DIAMETER SHALL BE PROVIDED AND
SHALL ORIGINATE AT A SERVICE PANEL OR A SUBPANEL(S) SERVING
THE AREA, AND SHALL TERMINATE IN CLOSE PROXIMITY TO THE
PROPOSED LOCATION OF THE EV CAPABLE SPACE AND INTO A
SUITABLE LISTED CABINET, BOX, ENCLOSURE OR EQUIVALENT. A
COMMON RACEWAY MAY BE USED TO SERVE MULTIPLE EV CAPABLE
SPACES.
2. A SERVICE PANEL OR SUBPANEL(S) SHALL BE PROVIDED WITH
PANEL SPACE AND ELECTRICAL LOAD CAPACITY FOR A DEDICATED
208/240 VOLT, 40-AMPERE MINIMUM BRANCH CIRCUIT FOR EACH EV
CAPABLE SPACE, WITH DELIVERY OF 30-AMPERE MINIMUM TO AN
INSTALLED EVSE AT EACH EVCS.
3. THE ELECTRICAL SYSTEM AND ANY ON-SITE DISTRIBUTION
TRANSFORMERS SHALL HAVE SUFFICIENT CAPACITY TO SUPPLY
FULL RATED AMPERAGE AT EACH EV CAPABLE SPACE.
4. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL
IDENTIFY THE RESERVED OVERCURRENT PROTECTIVE DEVICE
SPACE(S) AS "EV CAPABLE". THE RACEWAY TERMINATION LOCATION
SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE."
NOTE: A PARKING SPACE SERVED BY ELECTRIC VEHICLE SUPPLY
EQUIPMENT OR DESIGNED AS A FUTURE EV CHARGING SPACE SHALL
COUNT AS AT LEAST ONE STANDARD AUTOMOBILE PARKING SPACE
ONLY FOR THE PURPOSE OF COMPLYING WITH ANY APPLICABLE
MINIMUM PARKING SPACE REQUIREMENTS ESTABLISHED BY AN
ENFORCEMENT AGENCY. SEE VEHICLE CODE SECTION 22511.2 FOR
FURTHER DETAILS.
2 THE NUMBER OF REQUIRED EVCS (EV CAPABLE SPACES PROVIDED WITH
EVSE) IN COLUMN 3 COUNT TOWARD THE TOTAL NUMBER OF REQUIRED EV
CAPABLE SPACES SHOWN IN COLUMN 2.
SECTION 303 PHASED PROJECTS
303.1 PHASED PROJECTS.
FOR SHELL BUILDINGS AND OTHERS CONSTRUCTED FOR FUTURE TENANT
IMPROVEMENTS, ONLY THOSE CODE MEASURES RELEVANT TO THE
BUILDING COMPONENTS AND SYSTEMS CONSIDERED TO BE NEW
CONSTRUCTION (OR NEWLY CONSTRUCTED) SHALL APPLY.
303.1.1 INITIAL TENANT IMPROVEMENTS
THE PROVISIONS OF THIS CODE SHALL APPLY ONNLY TO THE INITIAL
TENANT IMPROVEMENTS TO A PROJECT. SUBSEQUENT TENANT
IMPROVEMENTS SHALL COMPLY WITH THE SCOPING PROVISIONS IN
SECTION 301.3 NON-RESIDENTIAL ADDITIONS AND ALTERATIONS.
1 IESNA LIGHTING ZONES 0 ARE NOT APPLICABLE; REFER TO LIGHTING
ZONES AS DEFINED IN THE CALIFORNIA ENERGY CODE AND CHAPTER 10
OF THE CALIFORNIA ADMINISTRATIVE CODE.
2 FOR PROPERTY LINES THAT ABUT PUBLIC WALKWAYS, BIKEWAYS,
PLAZAS AND PARKING LOTS, THE PROPERTY LINE MAY BE CONSIDERED TO
BE 5 FEET BEYOND THE ACTUAL PROPERTY LINE FOR PURPOSE OF
DETERMINING COMPLIANCE WITH THIS SECTION. FOR PROPERTY LINES
THAT ABUT PUBLIC ROADWAYS AND PUBLIC TRANSIT CORRIDORS, THE
5.106.8.1 FACING -BACKLIGHT
LUMINAIRES WITHIN 2MH OF A PROPERTY LINE SHALL BE ORIENTED SO THAT
THE NEAREST PROPERTY LINE IS BEHIND THE FIXTURE, AND SHALL COMPLY
WITH THE BACKLIGHT RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE
LIGHTING ZONE AND DISTANCE TO THE NEAREST POINT OF THAT PROPERTY
LINE.
EXCEPTION:CORNERS. IF TWO PROPERTY LINES (OR TWO SEGMENTS OF THE
SAME PROPERTY LINE) HAVE EQUIDISTANT POINTS TO THE LUMINAIRE, THEN
THE LUMINAIRE MAY BE ORIENTED SO THAT THE INTERSECTION OF THE TWO
LINES (THE CORNER) IS DIRECTLY BEHIND THE LUMINAIRE. THE LUMINAIRE
SHALL STILL USE THE DISTANCE TO THE NEAREST POINT(S) ON THE PROPERTY
LINES TO DETERMINE THE REQUIRED BACKLIGHT RATING.
5.106.8.2 FACING -GLARE
FOR LUMINAIRES COVERED BY 5.106.8.1, IF A PROPERTY LINE ALSO EXISTS
WITHIN OR EXTENDS INTO THE FRONT HEMISPHERE WITHIN 2MH OF THE
LUMINAIRE THEN THE LUMINAIRE SHALL COMPLY WITH THE MORE STRINGENT
GLARE RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE LIGHTING ZONE AND
DISTANCE TO THE NEAREST POINT ON THE NEAREST PROPERTY LINE WITHIN
THE FRONT HEMISPHERE.
5.106.10 GRADING AND PAVING
CONSTRUCTION PLANS SHALL INDICATE HOW SITE GRADING OR A DRAINAGE
SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM
ENTERING BUILDINGS. EXAMPLES OF METHODS TO MANAGE SURFACE WATER
INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:
1. SWALES.
2. WATER COLLECTION AND DISPOSAL SYSTEMS.
3. FRENCH DRAINS.
4. WATER RETENTION GARDENS.
5. OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM
BUILDINGS AND AID IN GROUNDWATER RECHARGE.
EXCEPTION:ADDITIONS AND ALTERATIONS NOT ALTERING THE DRAINAGE
PATH.
5.106.12 SHADE TREES
[DSA-SS] SHADE TREES SHALL BE PLANTED TO COMPLY WITH SECTIONS
5.106.12.1, 5.106.12.2, AND 5.106.12.3. PERCENTAGES SHOWN SHALL BE
MEASURED AT NOON ON THE SUMMER SOLSTICE. LANDSCAPE IRRIGATION
NECESSARY TO ESTABLISH AND MAINTAIN TREE HEALTH SHALL COMPLY WITH
SECTION 5.304.6.
5.106.12.1 SURFACE PARKING AREAS
SHADE TREE PLANTINGS, MINIMUM #10 CONTAINER SIZE OR EQUAL, SHALL
BE INSTALLED TO PROVIDE SHADE OVER 50 PERCENT OF THE PARKING
AREA WITHIN 15 YEARS.
EXCEPTIONS:THE SURFACE PARKING AREA COVERED BY SOLAR
PHOTOVOLTAIC SHADE STRUCTURES, OR SHADE STRUCTURES, WITH
ROOFING MATERIALS THAT COMPLY WITH TABLE A5.106.11.2.2 IN
APPENDIX A5, SHALL BE PERMITTED IN WHOLE OR IN PART IN LIEU OF
SHADE TREE PLANTINGS.
5.106.12.2 LANDSCAPE AREAS
SHADE TRESS PLANTINGS, MINIMUM #10 CONTAINER SIZE OR EQUAL SHALL
BE INSTALLED TO PROVIDE SHADE OF 20% OF THE LANDSCAPE AREA
WITHIN 15 YEARS.
EXCEPTIONS:PLAYFIELDS FOR ORGANIZED SPORT ACTIVITY ARE NOT
INCLUDED IN THE TOTAL AREA CALCULATION.
5.106.12.3. HARDSCAPE AREAS.
SHADE TREE PLANTINGS, MINIMUM #10 CONTAINER SIZE OR EQUAL SHALL
BE INSTALLED TO PROVIDE SHADE OVER 20% OF THE HARDSCAPE AREA
WITHIN 15 YEARS.
EXCEPTIONS:WALKS, HARDSCAPE AREAS COVERED BY SOLAR
PHOTOVOLTAIC SHADE STRUCTURES, AND HARDSCAPE AREAS
COVERED BY SHADE STRUCTURES WITH ROOFING MATERIALS THAT
COMPLY WITH TABLE A5.106.11.2.2 IN APPENDIX A5, SHALL BE
PERMITTED IN WHOLE OR IN PART IN LIEU OF SHADE TREE PLANTINGS.
DESIGNATED AND MARKED PLAY AREAS OF ORGANIZED SPORT
ACTIVITY ARE NOT INCLUDED IN THE TOTAL AREA CALCULATION..
5.303 INDOOR WATER USE
DIVISION 5.3 WATER EFFICIENCY AND
CONSERVATION
5.201 GENERAL
DIVISION 5.2 ENERGY EFFICIENCY
5.201.1 SCOPE.CALIFORNIA ENERGY CODE
FOR THE PURPOSES OF MANDATORY ENERGY EFFICIENCY STANDARDS IN THIS
CODE, THE CALIFORNIA ENERGY COMMISSION WILL CONTINUE TO ADOPT
MANDATORY BUILDING STANDARDS.
5.301 GENERAL
5.301.1 SCOPE
THE PROVISIONS OF THIS CHAPTER SHALL ESTABLISH THE MEANS OF
CONSERVING WATER USED INDOORS, OUTDOORS AND IN WASTEWATER
CONVEYANCE.
PROPERTY LINE MAY BE CONSIDERED TO BE THE CENTERLINE OF THE
PUBLIC ROADWAY OR PUBLIC TRANSIT CORRIDOR FOR THE PURPOSE OF
DETERMINING COMPLIANCE WITH THIS SECTION.
3 GENERAL LIGHTING LUMINAIRES IN AREAS SUCH AS OUTDOOR PARKING,
SALES OR STORAGE LOTS SHALL MEET THESE REDUCED RATINGS.
DECORATIVE LUMINAIRES LOCATED IN THESE AREAS SHALL MEET U-
VALUE LIMITS FOR "ALL OTHER OUTDOOR LIGHTING."
9/13/24
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
CA
L
G
R
E
E
N
R
E
Q
U
I
R
E
M
E
N
T
S
G-204
JH
JR
6/20/24
JR
ARCHITECTURAL APPLICATIONS
TABLE 5.504.4.1 - ADHESIVE VOC LIMIT
1,2
INDOOR CARPET ADHESIVES
CARPET PAD ADHESIVES
OUTDOOR CARPET ADHESIVES
WOOD FLOORING ADHESIVES
RUBBER FLOORING ADHESIVES
SUBFLOOR ADHESIVES
CERAMIC TILE ADHESIVES
CURRENT VOC LIMIT
50
50
150
100
60
50
65
(LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER)
VCT AND ASPHALT TILE ADHESIVES
DRYWALL AND PANEL ADHESIVES
COVE BASE ADHESIVES
MULTIPURPOSE CONSTRUCTION ADHESIVES
STRUCTURAL GLAZING ADHESIVES
SINGLE-PLY ROOF MEMBRANE ADHESIVES
OTHER ADHESIVES NOT SPECIFICALLY LISTED
50
50
50
70
100
250
50
SPECIALTY APPLICATIONS
PVC WELDING
CPVC WELDING
ABS WELDING
PLASTIC CEMENT WELDING
ADHESIVE PRIMER FOR PLASTIC
CONTACT ADHESIVE
SPECIAL PURPOSE CONTACT ADHESIVE
510
490
325
250
550
80
250
STRUCTURAL WOOD MEMBER ADHESIVE
TOP AND TRIM ADHESIVES
SUBSTRATE SPECIFIC APPLICATIONS
METAL TO METAL
PLASTIC FOAMS
POROUS MATERIAL (EXCEPT WOOD)
WOOD
FIBERGLASS
250
140
30
50
50
30
80
1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES
TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL
BE ALLOWED.
2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE
THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR
QUALITY MANAGEMENT DISTRICT RULE 1168.
HTTP://WWW.ARB.CA.GOV/DRDB/SC/CURHTML/R1168.PDF.
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
NONRESIDENTIAL MANDATORY MEASURES, SHEET 2 (JANUARY 2023)
5.303.1.2 EXCESS CONSUMPTION
A SEPARATE SUBMETER OR METERING DEVICE SHALL BE PROVIDED FOR
ANY TENANT WITHIN A NEW BUILDING OR WITHIN AN ADDITION THAT IS
PROJECTED TO CONSUME MORE THAN 1,000 GAL/DAY.
5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS
PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS
AND SHOWERHEADS) SHALL COMPLY WITH THE FOLLOWING:
5.303.3.1 WATER CLOSETS
THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT
EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE
CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE
SPECIFICATION FOR TANK-TYPE TOILETS.
NOTE:THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED
AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES
AND ONE FULL FLUSH.
5.303.3.2 URINALS
5.303.3.2.1 WALL-MOUNTED URINALS
THE EFFECTIVE FLUSH VOLUME OF WALL-MOUNTED URINALS SHALL
NOT EXCEED 0.125 GALLONS PER FLUSH.
5.303.3.2.2 FLOOR-MOUNTED URINALS
THE EFFECTIVE FLUSH VOLUME OF FLOOR-MOUNTED OR OTHER
URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH.
5.303.3.3 SHOWERHEADS.
5.303.3.3.1 SINGLE SHOWERHEAD
SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE
THAN 1.8 GALLONS PER MINUTE AT 80 PSI. SHOWERHEADS SHALL BE
CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA
WATERSENSE SPECIFICATION FOR SHOWERHEADS.
5.303.3.3.2 MULTIPLE SHOWERHEADS SERVING ONE SHOWER
WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE
COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER
SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT
EXCEED 1.8 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE
DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN OPERATION
AT A TIME.
NOTE:A HAND-HELD SHOWER SHALL BE CONSIDERED A SHOWERHEAD.
5.303.3.4 FAUCETS AND FOUNTAINS
5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS
LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE
THAN 0.5 GALLONS PER MINUTE AT 60 PSI.
5.303.3.4.2 KITCHEN FAUCETS
KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE
THAN 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY
TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT
NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI, AND MUST
DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60
PSI.
5.303.3.4.3 WASH FOUNTAINS
WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE
THAN 1.8 GALLONS PER MINUTE/20 [RIM SPACE (INCHES) AT 60 PSI].
5.303.3.4.4 METERING FAUCETS
METERING FAUCETS SHALL NOT DELIVER MORE THAN 0.20 GALLONS
PER CYCLE.
5.303.3.4.5 METERING FAUCETS FOR WASH FOUNTAINS
METERING FAUCETS FOR WASH FOUNTAINS SHALL HAVE A MAXIMUM
FLOW RATE OF NOT MORE THAN 0.20 GALLONS PER CYCLE/20 [RIM
SPACE (INCHES) AT 60 PSI].
NOTE:WHERE COMPLYING FAUCETS ARE UNAVAILABLE, AERATORS OR
OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION.
5.303.3.4.6 PRE-RINSE SPRAY VALVE
WHEN INSTALLED, SHALL MEET THE REQUIREMENTS IN THE CALIFORNIA
CODE OF REGULATIONS, TITLE 20 (APPLIANCE EFFICIENCY
REGULATIONS), SECTION 1605.1(H)(4) TABLE H-2, SECTION 1605.3(H)(4)(A),
AND SECTION 1607(D)(7), AND SHALL BE EQUIPPED WITH AN INTEGRAL
AUTOMATIC SHUTOFF.
5.303.4 COMMERCIAL KITCHEN EQUIPMENT
5.303.4.1 FOOD WASTE DISPOSERS
DISPOSERS SHALL EITHER MODULATE THE USE OF WATER TO NO MORE
THAN 1 GPM WHEN THE DISPOSER IS NOT IN USE (NOT ACTIVELY
GRINDING FOOD WASTE/NO-LOAD) OR SHALL AUTOMATICALLY SHUT
OFF AFTER NO MORE THAN 10 MINUTES OF INACTIVITY. DISPOSERS
SHALL USE NO MORE THAN 8 GPM OF WATER.
NOTE:THIS CODE SECTION DOES NOT AFFECT LOCAL JURISDICTION
AUTHORITY TO PROHIBIT OR REQUIRE DISPOSER INSTALLATION.
5.303.5 AREAS OF ADDITION OR ALTERATION
FOR THOSE OCCUPANCIES WITHIN THE AUTHORITY OF THE CALIFORNIA
BUILDING STANDARDS COMMISSION AS SPECIFIED IN SECTION 103, THE
PROVISIONS OF SECTIONS 5.303.3 AND 5.303.4 SHALL APPLY TO NEW
FIXTURES IN ADDITIONS OR AREAS OF ALTERATION TO THE BUILDING.
5.303.6 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS
PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE
WITH THE CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE
STANDARDS REFERENCED IN TABLE 1701.1 OF THE CALIFORNIA PLUMBING
CODE AND IN CHAPTER 6 OF THIS CODE.
5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT
5.407.1 WEATHER PROTECTION
PROVIDE A WEATHER-RESISTANT EXTERIOR WALL AND FOUNDATION
ENVELOPE AS REQUIRED BY CALIFORNIA BUILDING CODE SECTION 1402.2
(WEATHER PROTECTION), MANUFACTURER’S INSTALLATION INSTRUCTIONS OR
LOCAL ORDINANCE, WHICHEVER IS MORE STRINGENT.
5.407.2 MOISTURE CONTROL
EMPLOY MOISTURE CONTROL MEASURES BY THE FOLLOWING METHODS.
5.407.2.1 SPRINKLERS
DESIGN AND MAINTAIN LANDSCAPE IRRIGATION SYSTEMS TO PREVENT
SPRAY ON STRUCTURES.
5.407.2.2 ENTRIES AND OPENINGS
DESIGN EXTERIOR ENTRIES AND/OR OPENINGS SUBJECT TO FOOT TRAFFIC
OR WIND-DRIVEN RAIN TO PREVENT WATER INTRUSION INTO BUILDINGS AS
FOLLOWS:
5.407.2.2.1 EXTERIOR DOOR PROTECTION
PRIMARY EXTERIOR ENTRIES SHALL BE COVERED TO PREVENT WATER
INTRUSION BY USING NONABSORBENT FLOOR AND WALL FINISHES
WITHIN AT LEAST 2 FEET AROUND AND PERPENDICULAR TO SUCH
OPENINGS PLUS AT LEAST ONE OF THE FOLLOWING:
1. AN INSTALLED AWNING AT LEAST 4 FEET IN DEPTH.
2. THE DOOR IS PROTECTED BY A ROOF OVERHANG AT LEAST 4
FEET IN DEPTH.
3. THE DOOR IS RECESSED AT LEAST 4 FEET.
4. OTHER METHODS WHICH PROVIDE EQUIVALENT PROTECTION.
5.407.2.2.2 FLASHING
INSTALL FLASHINGS INTEGRATED WITH A DRAINAGE PLANE.
SECTION 5.408 CONSTRUCTION WASTE REDUCTION,
DISPOSAL AND RECYCLING
5.408.1 CONSTRUCTION WASTE MANAGEMENT
RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE
NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE
WITH SECTION 5.408.1.1, 5.408.1.2 OR 5.408.1.3; OR MEET A LOCAL
CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE,
WHICHEVER IS MORE STRINGENT.
5.408.1.1 CONSTRUCTION WASTE MANAGEMENT PLAN
WHERE A LOCAL JURISDICTION DOES NOT HAVE A CONSTRUCTION AND
DEMOLITION WASTE MANAGEMENT ORDINANCE THAT IS MORE STRINGENT,
SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN THAT
1. IDENTIFIES THE CONSTRUCTION AND DEMOLITION WASTE MATERIALS
TO BE DIVERTED FROM DISPOSAL BY EFFICIENT USAGE, RECYCLING,
REUSE ON THE PROJECT OR SALVAGE FOR FUTURE USE OR SALE.
2. DETERMINES IF CONSTRUCTION AND DEMOLITION WASTE MATERIALS
WILL BE SORTED ON-SITE (SOURCE-SEPARATED) OR BULK MIXED
(SINGLE STREAM).
3. IDENTIFIES DIVERSION FACILITIES WHERE CONSTRUCTION AND
DEMOLITION WASTE MATERIAL COLLECTED WILL BE TAKEN.
4. SPECIFIES THAT THE AMOUNT OF CONSTRUCTION AND DEMOLITION
WASTE MATERIALS DIVERTED SHALL BE CALCULATED BY WEIGHT OR
VOLUME, BUT NOT BY BOTH.}
5.408.1.2 WASTE MANAGEMENT COMPANY
UTILIZE A WASTE MANAGEMENT COMPANY THAT CAN PROVIDE VERIFIABLE
DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND
DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES
WITH THIS SECTION.
NOTE:THE OWNER OR CONTRACTOR SHALL MAKE THE DETERMINATION IF
THE CONSTRUCTION AND DEMOLITION WASTE MATERIAL WILL BE DIVERTED
BY A WASTE MANAGEMENT COMPANY.
EXCEPTIONS TO SECTIONS 5.408.1.1 AND 5.408.1.2:
1. EXCAVATED SOIL AND LAND-CLEARING DEBRIS.
2. ALTERNATE WASTE REDUCTION METHODS DEVELOPED BY WORKING
WITH LOCAL AGENCIES IF DIVERSION OR RECYCLE FACILITIES CAPABLE
OF COMPLIANCE WITH THIS ITEM DO NOT EXIST.
3. DEMOLITION WASTE MEETING LOCAL ORDINANCE OR CALCULATED IN
CONSIDERATION OF LOCAL RECYCLING FACILITIES AND MARKETS.
5.408.1.3 WASTE STREAM REDUCTION ALTERNATIVE
THE COMBINED WEIGHT OF NEW CONSTRUCTION DISPOSAL THAT DOES
NOT EXCEED TWO POUNDS PER SQUARE FOOT OF BUILDING AREA MAY BE
DEEMED TO MEET THE 65 PERCENT MINIMUM REQUIREMENT AS APPROVED
BY THE ENFORCING AGENCY.
5.408.1.4 DOCUMENTATION
DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH
DEMONSTRATES COMPLIANCE WITH SECTIONS 5.408.1.1 THROUGH 5.408.1.3.
THE WASTE MANAGEMENT PLAN SHALL BE UPDATED AS NECESSARY AND
SHALL BE ACCESSIBLE DURING CONSTRUCTION FOR EXAMINATION BY THE
ENFORCING AGENCY.
NOTES:
1. SAMPLE FORMS FOUND IN “A GUIDE TO THE CALIFORNIA GREEN BUILDING
STANDARDS CODE (NONRESIDENTIAL)”LOCATED AT
https://www.dgs.ca.gov/BSC/Resources/Page-Content/Building-Standards-
CommissionResources-List-Folder/CALGreen MAY BE USED TO ASSIST IN
DOCUMENTING COMPLIANCE WITH THE WASTE MANAGEMENT PLAN.
2. MIXED CONSTRUCTION AND DEMOLITION DEBRIS (C&D) PROCESSORS CAN
BE LOCATED AT THE CALIFORNIA DEPARTMENT OF RESOURCES RECYCLING
AND RECOVERY (CALRECYCLE).
5.408.2 UNIVERSAL WASTE.
[A] ADDITIONS AND ALTERATIONS TO A BUILDING OR TENANT SPACE THAT
MEET THE SCOPING PROVISIONS IN SECTION 301.3 FOR NONRESIDENTIAL
ADDITIONS AND ALTERATIONS, SHALL REQUIRE VERIFICATION THAT
5.401 GENERAL
5.401.1 SCOPE
THE PROVISIONS OF THIS CHAPTER SHALL OUTLINE MEANS OF ACHIEVING
MATERIAL CONSERVATION AND RESOURCE EFFICIENCY THROUGH
PROTECTION OF BUILDINGS FROM EXTERIOR MOISTURE, CONSTRUCTION
WASTE DIVERSION, EMPLOYMENT OF TECHNIQUES TO REDUCE POLLUTION
THROUGH RECYCLING OF MATERIALS, AND BUILDING COMMISSIONING OR
TESTING AND ADJUSTING.
DIVISION 5.4 MATERIAL CONSERVATION
AND RESOURCE EFFICIENCY
5.410 BUILDING MAINTENANCE AND OPERATIONS
5.410.1 RECYCLING BY OCCUPANTS
PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING
AND ARE IDENTIFIED FOR THE DEPOSITING, STORAGE AND COLLECTION OF
NON-HAZARDOUS MATERIALS FOR RECYCLING, INCLUDING (AT A MINIMUM)
PAPER, CORRUGATED CARDBOARD, GLASS, PLASTICS, ORGANIC WASTE,
AND METALS OR MEET A LAWFULLY ENACTED LOCAL RECYCLING
ORDINANCE, IF MORE RESTRICTIVE.
EXCEPTION:RURAL JURISDICTIONS THAT MEET AND APPLY FOR THE
EXEMPTION IN PUBLIC RESOURCES CODE 42649.82 (A)(2)(A) ET SEQ.
SHALL ALSO BE EXEMPT FROM THE ORGANIC WASTE PORTION OF THIS
SECTION.
5.410.1.1 ADDITIONS
ALL ADDITIONS CONDUCTED WITHIN A 12-MONTH PERIOD UNDER
SINGLE OR MULTIPLE PERMITS, RESULTING IN AN INCREASE OF 30
PERCENT OR MORE IN FLOOR AREA, SHALL PROVIDE RECYCLING AREAS
ON SITE.
EXCEPTION:ADDITIONS WITHIN A TENANT SPACE RESULTING IN
LESS THAN A 30-PERCENT INCREASE IN THE TENANT SPACE FLOOR
AREA.
5.410.1.2 SAMPLE ORDINANCE
SPACE ALLOCATION FOR RECYCLING AREAS SHALL COMPLY WITH
CHAPTER 18, PART 3, DIVISION 30 OF THE PUBLIC RESOURCES CODE.
CHAPTER 18 IS KNOWN AS THE CALIFORNIA SOLID WASTE REUSE AND
RECYCLING ACCESS ACT OF 1991 (ACT).
NOTE:A SAMPLE ORDINANCE FOR USE BY LOCAL AGENCIES MAY BE
FOUND IN APPENDIX A OF THE DOCUMENT AT THE CALRECYCLE’S
WEBSITE
5.501 GENERAL
DIVISION 5.5 ENVIRONMENTAL QUALITY
5.501.1 SCOPE
THE PROVISIONS OF THIS CHAPTER SHALL OUTLINE MEANS OF REDUCING
THE QUANTITY OF AIR CONTAMINANTS THAT ARE ODOROUS, IRRITATING,
AND/OR HARMFUL TO THE COMFORT AND WELL-BEING OF A BUILDING’S
INSTALLERS, OCCUPANTS AND NEIGHBORS.
5.503 FIREPLACES
5.503.1 FIREPLACES
INSTALL ONLY A DIRECT-VENT SEALED-COMBUSTION GAS OR SEALED
WOOD-BURNING FIREPLACE, OR A SEALED WOOD-STOVE OR PELLET
STOVE, AND REFER TO RESIDENTIAL REQUIREMENTS IN THE CALIFORNIA
ENERGY CODE, TITLE 24, PART 6, SUBCHAPTER 7, SECTION 150.
WOODSTOVES, PELLET STOVES AND FIREPLACES SHALL COMPLY WITH
APPLICABLE LOCAL ORDINANCES.
5.503.1.1 WOODSTOVES
WOODSTOVE AND PELLET STOVES SHALL COMPLY WITH U.S. EPA NEW
SOURCE PERFORMANCE STANDARDS (NSPS) EMISSION LIMITS AS
APPLICABLE, AND SHALL HAVE A PERMANENT LABEL INDICATING THEY
ARE CERTIFIED TO MEET THE EMISSION LIMITS.
5.504 POLLUTANT CONTROL
5.504.1 TEMPORARY VENTILATION
THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING
CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR AREAS OF
ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE
FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS
USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM
EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE 52.2-1999,
OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992.
REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE
BUILDING IS OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF
CONSTRUCTION.
5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL
EQUIPMENT DURING CONSTRUCTION
AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND
VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR
DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE,
PLASTIC, SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE
ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND
DEBRIS WHICH MAY ENTER THE SYSTEM.
5.504.4 FINISH MATERIAL POLLUTANT CONTROL
FINISH MATERIALS SHALL COMPLY WITH SECTIONS 5.504.4.1 THROUGH
5.504.4.6.
5.504.4.1 ADHESIVES, SEALANTS AND CAULKS
ADHESIVES, SEALANTS, AND CAULKS USED ON THE PROJECT SHALL
MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS:
1. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS,
SEALANTS, SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH
LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY
MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD
RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2.
SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE 1168
PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS
(CHLOROFORM, ETHYLENE DICHLORIDE, METHYLENE CHLORIDE,
PERCHLOROETHYLENE AND TRICHLOROETHYLENE), EXCEPT FOR
AEROSOL PRODUCTS AS SPECIFIED IN SUBSECTION 2, BELOW.
2. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES,
AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT,
LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND
AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL
COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER
REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN
TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE
17, COMMENCING WITH SECTION 94507.
5.304.6.1 NEWLY CONSTRUCTED LANDSCAPES
NEW CONSTRUCTION PROJECTS WITH AN AGGREGATE LANDSCAPE
AREA EQUAL TO OR GREATER THAN 500 SQUARE FEET.
5.304.6.2 REHABILITATED LANDSCAPES
REHABILITATED LANDSCAPE PROJECTS WITH AN AGGREGATE
LANDSCAPE AREA EQUAL TO OR GREATER THAN 1,200 SQUARE FEET.
UNIVERSAL WASTE ITEMS SUCH AS FLUORESCENT LAMPS AND BALLAST
AND MERCURY CONTAINING THERMOSTATS AS WELL AS OTHER
CALIFORNIA PROHIBITED UNIVERSAL WASTE MATERIALS ARE DISPOSED OF
PROPERLY AND ARE DIVERTED FROM LANDFILLS. A LIST OF PROHIBITED
UNIVERSAL WASTE MATERIALS SHALL BE INCLUDED IN THE CONSTRUCTION
DOCUMENTS.
NOTE:REFER TO THE UNIVERSAL WASTE RULE LINK AT:
https://dtsc.ca.gov/universalwaste/
5.408.3 EXCAVATED SOIL AND LAND CLEARING DEBRIS
100 PERCENT OF TREES, STUMPS, ROCKS AND ASSOCIATED VEGETATION
AND SOILS RESULTING PRIMARILY FROM LAND CLEARING SHALL BE REUSED
OR RECYCLED. FOR A PHASED PROJECT, SUCH MATERIAL MAY BE
STOCKPILED ON SITE UNTIL THE STORAGE SITE IS DEVELOPED.
EXCEPTION:REUSE, EITHER ON-OR OFF-SITE, OF VEGETATION OR SOIL
CONTAMINATED BY DISEASE OR PEST INFESTATION.
NOTES:
1. IF CONTAMINATION BY DISEASE OR PEST INFESTATION IS SUSPECTED,
CONTACT THE COUNTY AGRICULTURAL COMMISSIONER AND FOLLOW
ITS DIRECTION FOR RECYCLING OR DISPOSAL OF THE MATERIAL.
(www.cdfa.ca.gov/exec/county/county_contacts.html)
2. FOR A MAP OF KNOWN PEST AND/OR DISEASE QUARANTINE ZONES,
CONSULT WITH THE CALIFORNIA DEPARTMENT OF FOOD AND
AGRICULTURE. (www.cdfa.ca.gov)
9/13/24
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
CA
L
G
R
E
E
N
R
E
Q
U
I
R
E
M
E
N
T
S
G-205
JH
JR
6/20/24
JR
COATING CATEGORY
TABLE 5.504.4.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2, 3
FLAT COATINGS
NONFLAT COATINGS
NONFLAT-HIGH GLOSS COATINGS
SPECIALTY COATINGS
ALUMINUM ROOF COATINGS
BASEMENT SPECIALTY COATINGS
BITUMINOUS ROOF COATINGS
CURRENT VOC LIMIT
50
100
150
400
400
50
(GRAMS OF VOC PER LITER OF COATING, LESS WATER AND LESS EXEMPT COMPOUNDS)
BITUMINOUS ROOF PRIMERS
BOND BREAKERS
CONCRETE CURING COMPOUNDS
CONCRETE/MASONRY SEALERS
DRIVEWAY SEALERS
DRY FOG COATINGS
FAUX FINISHING COATINGS
350
350
350
100
50
150
350
FLOOR COATINGS
FORM-RELEASE COMPOUNDS
GRAPHIC ARTS COATINGS (SIGN PAINTS)
HIGH TEMPERATURE COATINGS
IDUSTRIAL MAINTENANCE COATINGS
LOW SOLIDS COATINGS1
MAGNESITE CEMENT COATINGS
MASTIC TEXTURE COATINGS
100
250
500
420
250
120
450
100
FIRE RESISTIVE COATINGS 350
METALLIC PIGMENTED COATINGS
MULTICOLOR COATINGS
PRETREATMENT WASH PRIMERS
PRIMERS, SEALERS, AND UNDERCOATERS
REACTIVE PENETRATING SEALERS
RECYCLED COATINGS
ROOF COATINGS
RUST PREVENTATIVE COATINGS
420
250
500
100
350
250
50
250
SHELLACS
CLEAR 730
OPAQUE 550
SPECIALTY PRIMERS, SEALERS AND
UNDERCOATERS
100
STAINS 250
STONE CONSOLIDANTS 450
SWIMMING POOL COATINGS 340
TRAFFIC MARKING COATINGS 100
TUB AND TILE REFINISH COATINGS 420
WATERPROOFING MEMBRANES 250
WOOD COATINGS 275
WOOD PRESERVATIVES 350
ZINC-RICH PRIMERS 340
1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER AND
INCLUDING EXEMPT COMPOUNDS.
2. THE SPECIFIED LIMITS REMAIN IN EFFECT ENLESS REVISED LIMITS ARE
LISTED IN SUBSEQUENT COLUMNS IN THE TABLE
3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE
CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS
SUGGESTED CONTROL MEASURE, FEBUARY 1, 2008. MORE
INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD.
PRODUCT
TABLE 5.504.4.5 - FORMALDEHYDE LIMITS
1
HARDWOOD PLYWOOD VENEER CORE
HARDWOOD PLYWOOD COMPOSITE CORE
PARTICLEBOARD
MEDIUM DENSITY FIBERBOARD
THIN MEDIUM DENSITY FIBERBOARD2
CURRENT LIMIT
0.05
0.05
0.09
0.11
0.13
(MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION)
1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY
THE CALIFORNIA AIR RESOURCES BOARD, AIR TOXICS CONTROL
MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE
WITH ASTM E1333. FOR ADDITIONAL INFORMATION, SEE
CALIFORNIA CODE OF REGULATIONS, TITLE 17, SECTIONS 93120
THROUGH 93120.12.
2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS
OF 5/16 INCH (8MM).
SEALANTS
TABLE 5.504.4.2 - SEALANT VOC LIMIT
ARCHITECTURAL
MARINE DECK
NONMEMBRANE ROOF
ROADWAY
SINGLE-PLY ROOF MEMBRANE
OTHER
CURRENT VOC LIMIT
250
760
300
250
450
420
(LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER)
SEALANT PRIMERS
ARCHITECTURAL
NONPOROUS
POROUS
MODIFIED BITUMINOUS
250
775
500
MARINE DECK
OTHER
760
750
NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE
THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE SOUTH COAST AIR
QUALITY MANAGEMENT DISTRICT RULE 1168.
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
NONRESIDENTIAL MANDATORY MEASURES, SHEET 3 (JANUARY 2023)
5.504.4.3 PAINTS AND COATINGS
ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC
LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL COATINGS SUGGESTED
CONTROL MEASURE, AS SHOWN IN TABLE 5.504.4.3, UNLESS MORE
STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR
COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE SPECIALTY
COATINGS CATEGORIES LISTED IN TABLE 5.504.4.3 SHALL BE
DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR
NONFLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED IN
SUBSECTIONS 4.21, 4.36 AND 4.37 OF THE 2007 CALIFORNIA AIR
RESOURCES BOARD SUGGESTED CONTROL MEASURE, AND THE
CORRESPONDING FLAT, NONFLAT OR NONFLAT-HIGH GLOSS VOC LIMIT
IN TABLE 5.504.4.3 SHALL APPLY.
5.504.4.4 CARPET SYSTEMS
ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE
REQUIREMENTS FOR THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH,
"STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE
ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING
ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION
TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350).
SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR
CERTIFICATION PROGRAMS AND TESTING LABS.
https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.asp
x#material
5.504.4.4.1 CARPET CUSHION
ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL
MEET THE REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF
PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND
EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM
INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION
1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA
SPECIFICATION 01350).
SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR
CERTIFICATION PROGRAMS AND TESTING LABS.
https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC
.aspx#material
5.504.4.4.2 CARPET ADHESIVE
ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE
5.504.4.1.
5.504.4.5 COMPOSITE WOOD PRODUCTS
HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY
FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR
EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR
FORMALDEHYDE AS SPECIFIED IN ARB’S AIR TOXIC CONTROL MEASURE
(ATCM) FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ.) THOSE
MATERIALS NOT EXEMPTED UNDER THE ATCM MUST MEET THE
SPECIFIED EMISSION LIMITS, AS SHOWN IN TABLE 5.504.4.5.
5.504.4.5.3 DOCUMENTATION
VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE
PROVIDED AS REQUESTED BY THE ENFORCING AGENCY.
DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE
FOLLOWING:
1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS.
2. CHAIN OF CUSTODY CERTIFICATIONS.
3. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE
WOOD PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION
93120, ET SEQ.).
4. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR
PS-2 STANDARDS OF THE ENGINEERED WOOD ASSOCIATION,
THE AUSTRALIAN AS/NZS 2269 OR EUROPEAN 636 3S
STANDARDS.
OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY.
5.505.1 INDOOR MOISTURE CONTROL
BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF CALIFORNIA
BUILDING CODE, CCR, TITLE 24, PART 2, SECTIONS 1202 (VENTILATION) AND
CHAPTER 14 (EXTERIOR WALLS). FOR ADDITIONAL MEASURES, SEE SECTION
5.407.2 OF THIS CODE.
5.505 INDOOR MOISTURE CONTROL
5.506.1 OUTSIDE AIR DELIVERY
FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS,
MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 (REQUIREMENTS
FOR VENTILATION) OF THE CALIFORNIA ENERGY CODE,OR THE APPLICABLE
LOCAL CODE, WHICHEVER IS MORE STRINGENT, AND DIVISION 1, CHAPTER 4
OF CCR, TITLE 8.
5.506.2 CARBON DIOXIDE (CO2) MONITORING
FOR BUILDINGS OR ADDITIONS EQUIPPED WITH DEMAND CONTROL
VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE
SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF
THE CALIFORNIA ENERGY CODE,SECTION 120(C)(4).
5.506 INDOOR AIR QUALITY
5.507.4 ACOUSTICAL CONTROL
EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH SOUND
TRANSMISSION CLASS (STC) VALUES DETERMINED IN ACCORDANCE WITH ASTM
E90 AND ASTM E413 OR OUTDOOR-INDOOR SOUND TRANSMISSION CLASS
(OITC) DETERMINED IN ACCORDANCE WITH ASTM E1332, USING EITHER THE
PRESCRIPTIVE OR PERFORMANCE METHOD IN SECTION 5.507.4.1 OR 5.507.4.2.
EXCEPTION:BUILDINGS WITH FEW OR NO OCCUPANTS OR WHERE
OCCUPANTS ARE NOT LIKELY TO BE AFFECTED BY EXTERIOR NOISE, AS
DETERMINED BY THE ENFORCEMENT AUTHORITY, SUCH AS FACTORIES,
STADIUMS, STORAGE, ENCLOSED PARKING STRUCTURES AND UTILITY
BUILDINGS.
EXCEPTION: [DSA-SS]FOR PUBLIC SCHOOLS AND COMMUNITY COLLEGES,
THE REQUIREMENTS OF THIS SECTION AND ALL SUBSECTIONS APPLY ONLY
TO NEW CONSTRUCTION.
5.507.4.1 EXTERIOR NOISE TRANSMISSION, PRESCRIPTIVE METHOD
WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE
MAKING UP THE BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE
SHALL MEET A COMPOSITE STC RATING OF AT LEAST 50 OR A COMPOSITE
OITC RATING OF NO LESS THAN 40, WITH EXTERIOR WINDOWS OF A
MINIMUM STC OF 40 OR OITC OF 30 IN THE FOLLOWING LOCATIONS:
1. WITHIN THE 65 CNEL NOISE CONTOUR OF AN AIRPORT.
EXCEPTIONS:
1. LDN OR CNEL FOR MILITARY AIRPORTS SHALL BE
DETERMINED BY THE FACILITY AIR INSTALLATION
COMPATIBLE LAND USE ZONE (AICUZ) PLAN.
2. LDN OR CNEL FOR OTHER AIRPORTS AND HELIPORTS FOR
WHICH A LAND USE PLAN HAS NOT BEEN DEVELOPED SHALL
BE DETERMINED BY THE LOCAL GENERAL PLAN NOISE
ELEMENT.
2. WITHIN THE 65 CNEL OR LDN NOISE CONTOUR OF A FREEWAY OR
EXPRESSWAY, RAILROAD, INDUSTRIAL SOURCE OR FIXED-
GUIDEWAY SOURCE AS DETERMINED BY THE NOISE ELEMENT OF
THE GENERAL PLAN.
5.507.4.1.1 NOISE EXPOSURE WHERE NOISE CONTOURS ARE NOT
READILY AVAILABLE
BUILDINGS EXPOSED TO A NOISE LEVEL OF 65 DB LEQ-1-HR DURING ANY
HOUR OF OPERATION SHALL HAVE BUILDING, ADDITION OR ALTERATION
EXTERIOR WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE
NOISE SOURCE MEETING A COMPOSITE STC RATING OF AT LEAST 45
(OR OITC 35), WITH EXTERIOR WINDOWS OF A MINIMUM STC OF 40 (OR
OITC 30).
5.507.4.2 PERFORMANCE METHOD
FOR BUILDINGS LOCATED AS DEFINED IN SECTION 5.507.4.1 OR 5.507.4.1.1,
WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE
MAKING UP THE BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE
SHALL BE CONSTRUCTED TO PROVIDE AN INTERIOR NOISE ENVIRONMENT
ATTRIBUTABLE TO EXTERIOR SOURCES THAT DOES NOT EXCEED AN
HOURLY EQUIVALENT NOISE LEVEL (LEQ-1HR) OF 50 DBA IN OCCUPIED
AREAS DURING ANY HOUR OF OPERATION.
5.507.4.2.1 SITE FEATURES
EXTERIOR FEATURES SUCH AS SOUND WALLS OR EARTH BERMS MAY
BE UTILIZED AS APPROPRIATE TO THE BUILDING, ADDITION OR
ALTERATION PROJECT TO MITIGATE SOUND MIGRATION TO THE
INTERIOR.
5.507.4.2.2 DOCUMENTATION OF COMPLIANCE
AN ACOUSTICAL ANALYSIS DOCUMENTING COMPLYING INTERIOR
SOUND LEVELS SHALL BE PREPARED BY PERSONNEL APPROVED BY
THE ARCHITECT OR ENGINEER OF RECORD.
5.507.4.3 INTERIOR SOUND TRANSMISSION
WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES AND
TENANT SPACES AND PUBLIC PLACES SHALL HAVE AN STC OF AT LEAST 40.
NOTE:EXAMPLES OF ASSEMBLIES AND THEIR VARIOUS STC RATINGS
MAY BE FOUND AT THE CALIFORNIA OFFICE OF NOISE CONTROL:
www.toolbase.org/PDF/CaseStudies/stc_icc_ratings.pdf.
5.507 ENVIRONMENTAL COMFORT
702.1 INSTALLER TRAINING
HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE
PROPER INSTALLATION OF HVAC SYSTEMS INCLUDING DUCTS AND
EQUIPMENT BY A NATIONALLY OR REGIONALLY RECOGNIZED TRAINING OR
CERTIFICATION PROGRAM. UNCERTIFIED PERSONS MAY PERFORM HVAC
INSTALLATIONS WHEN UNDER THE DIRECT SUPERVISION AND
RESPONSIBILITY OF A PERSON TRAINED AND CERTIFIED TO INSTALL HVAC
SYSTEMS OR CONTRACTOR LICENSED TO INSTALL HVAC SYSTEMS.
EXAMPLES OF ACCEPTABLE HVAC TRAINING AND CERTIFICATION
PROGRAMS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING:
1. STATE CERTIFIED APPRENTICESHIP PROGRAMS.
2. PUBLIC UTILITY TRAINING PROGRAMS.
3. TRAINING PROGRAMS SPONSORED BY TRADE, LABOR OR
STATEWIDE ENERGY CONSULTING OR VERIFICATION
ORGANIZATIONS.
4. PROGRAMS SPONSORED BY MANUFACTURING ORGANIZATIONS.
5. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY.
702.2 SPECIAL INSPECTION [HCD]
WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE
RESPONSIBLE ENTITY ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE
OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER
DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE.
SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE
SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF
INSPECTION OR TASK TO BE PERFORMED. IN ADDITION TO OTHER
CERTIFICATIONS OR QUALIFICATIONS ACCEPTABLE TO THE ENFORCING
AGENCY, THE FOLLOWING CERTIFICATIONS OR EDUCATION MAY BE
CONSIDERED BY THE ENFORCING AGENCY WHEN EVALUATING THE
QUALIFICATIONS OF A SPECIAL INSPECTOR:
1. CERTIFICATION BY A NATIONAL OR REGIONAL GREEN BUILDING
PROGRAM OR STANDARD PUBLISHER.
2. CERTIFICATION BY A STATEWIDE ENERGY CONSULTING OR
VERIFICATION ORGANIZATION, SUCH AS HERS RATERS, BUILDING
PERFORMANCE CONTRACTORS, AND HOME ENERGY AUDITORS.
3. SUCCESSFUL COMPLETION OF A THIRD PARTY APPRENTICE TRAINING
PROGRAM IN THE APPROPRIATE TRADE.
4. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY.
NOTES:
1. SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO
FINANCIAL INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE
INSPECTING FOR COMPLIANCE WITH THIS CODE.
2. HERS RATERS ARE SPECIAL INSPECTORS CERTIFIED BY THE
CALIFORNIA ENERGY COMMISSION (CEC) TO RATE HOMES IN
CALIFORNIA ACCORDING TO THE HOME ENERGY RATING SYSTEM
(HERS).
[BSC-CG]WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR
THE RESPONSIBLE ENTITY ACTING AS THE OWNER'S AGENT SHALL EMPLOY
ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER
DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE.
SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE
SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF
INSPECTION OR TASK TO BE PERFORMED. IN ADDITION, THE SPECIAL
INSPECTOR SHALL HAVE A CERTIFICATION FROM A RECOGNIZED STATE,
NATIONAL OR INTERNATIONAL ASSOCIATION, AS DETERMINED BY THE
LOCAL AGENCY. THE AREA OF CERTIFICATION SHALL BE CLOSELY RELATED
TO THE PRIMARY JOB FUNCTION, AS DETERMINED BY THE LOCAL AGENCY.
NOTE:
SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO
FINANCIAL INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE
INSPECTING FOR COMPLIANCE WITH THIS CODE.
703.1 DOCUMENTATION.
DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL
INCLUDE BUT IS NOT LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS,
SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION
REPORTS, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY
WHICH DEMONSTRATE SUBSTANTIAL CONFORMANCE. WHEN SPECIFIC
DOCUMENTATION OR SPECIAL INSPECTION IS NECESSARY TO VERIFY
COMPLIANCE, THAT METHOD OF COMPLIANCE WILL BE SPECIFIED IN THE
APPROPRIATE SECTION OR IDENTIFIED APPLICABLE CHECKLIST.
CHAPTER 7 - INSTALLER &
SPECIAL INSPECTOR
QUALIFICATIONS
702 QUALIFICATIONS
703 VERIFICATIONS
OUTSIDE DIAMETER (OD) LESS THAN 1/4 INCH, FLARED TUBING
CONNECTIONS AND SHORT RADIUS ELBOWS SHALL NOT BE USED IN
REFRIGERANT SYSTEMS EXCEPT AS NOTED BELOW.
5.508.2.1.1 THREADED PIPE
THREADED CONNECTIONS ARE PERMITTED AT THE COMPRESSOR
RACK.
5.508.2.1.2 COPPER PIPE
COPPER TUBING WITH AN OD LESS THAN 1/4 INCH MAY BE USED IN
SYSTEMS WITH A REFRIGERANT CHARGE OF 5 POUNDS OR LESS.
5.508.2.1.2.1 ANCHORAGE
ONE-FOURTH-INCH OD TUBING SHALL BE SECURELY CLAMPED
TO A RIGID BASE TO KEEP VIBRATION LEVELS BELOW 8 MILS.
5.508.2.1.3 FLARED TUBING CONNECTIONS
DOUBLE-FLARED TUBING CONNECTIONS MAY BE USED FOR
PRESSURE CONTROLS, VALVE PILOT LINES AND OIL.
EXCEPTION:SINGLE-FLARED TUBING CONNECTIONS MAY BE
USED WITH A MULTIRING SEAL COATED WITH INDUSTRIAL
SEALANT SUITABLE FOR USE WITH REFRIGERANTS AND
TIGHTENED IN ACCORDANCE WITH MANUFACTURER’S
RECOMMENDATIONS.
5.508.2.1.4 ELBOWS
SHORT RADIUS ELBOWS ARE ONLY PERMITTED WHERE SPACE
LIMITATIONS PROHIBIT USE OF LONG RADIUS ELBOWS.
5.508.2.2 VALVES
VALVES AND FITTINGS SHALL COMPLY WITH THE CALIFORNIA
MECHANICAL CODE AND AS FOLLOWS.
5.508.2.2.1 PRESSURE RELIEF VALVES
FOR VESSELS CONTAINING HIGH-GWP REFRIGERANT, A RUPTURE
DISC SHALL BE INSTALLED BETWEEN THE OUTLET OF THE VESSEL
AND THE INLET OF THE PRESSURE RELIEF VALVE.
5.508.2.2.1.1 PRESSURE DETECTION
A PRESSURE GAUGE, PRESSURE TRANSDUCER OR OTHER
DEVICE SHALL BE INSTALLED IN THE SPACE BETWEEN THE
RUPTURE DISC AND THE RELIEF VALVE INLET TO INDICATE A
DISC RUPTURE OR DISCHARGE OF THE RELIEF VALVE.
5.508.2.2.2 ACCESS VALVES
ONLY SCHRADER ACCESS VALVES WITH A BRASS OR STEEL BODY
ARE PERMITTED FOR USE.
5.508.2.2.2.1 VALVE CAPS
FOR SYSTEMS WITH A REFRIGERANT CHARGE OF 5 POUNDS OR
MORE, VALVE CAPS SHALL BE BRASS OR STEEL AND NOT
PLASTIC.
5.508.2.2.2.2 SEAL CAPS
IF DESIGNED FOR IT, THE CAP SHALL HAVE A NEOPRENE O-RING
IN PLACE.
5.508.2.2.2.2.1 CHAIN TETHERS
CHAIN TETHERS TO FIT OVER THE STEM ARE REQUIRED FOR
VALVES DESIGNED TO HAVE SEAL CAPS.
EXCEPTION:VALVES WITH SEAL CAPS THAT ARE NOT
REMOVED FROM THE VALVE DURING STEM OPERATION.
5.508.2.3 REFRIGERATED SERVICE CASES
REFRIGERATED SERVICE CASES HOLDING FOOD PRODUCTS
CONTAINING VINEGAR AND SALT SHALL HAVE EVAPORATOR COILS OF
CORROSION-RESISTANT MATERIAL, SUCH AS STAINLESS STEEL; OR BE
COATED TO PREVENT CORROSION FROM THESE SUBSTANCES.
5.508.2.3.1 COIL COATING
CONSIDERATION SHALL BE GIVEN TO THE HEAT TRANSFER
EFFICIENCY OF COIL COATING TO MAXIMIZE ENERGY EFFICIENCY.
5.508.2.4 REFRIGERANT RECEIVERS
REFRIGERANT RECEIVERS WITH CAPACITIES GREATER THAN 200
POUNDS SHALL BE FITTED WITH A DEVICE THAT INDICATES THE LEVEL
OF REFRIGERANT IN THE RECEIVER.
5.508.2.5 PRESSURE TESTING
THE SYSTEM SHALL BE PRESSURE TESTED DURING INSTALLATION
PRIOR TO EVACUATION AND CHARGING.
5.508.2.5.1 MINIMUM PRESSURE
THE SYSTEM SHALL BE CHARGED WITH REGULATED DRY NITROGEN
AND APPROPRIATE TRACER GAS TO BRING SYSTEM PRESSURE UP
TO 300 PSIG MINIMUM.
5.508.2.5.2 LEAKS
CHECK THE SYSTEM FOR LEAKS, REPAIR ANY LEAKS, AND RETEST
FOR PRESSURE USING THE SAME GAUGE.
5.508.2.5.3 ALLOWABLE PRESSURE CHANGE
THE SYSTEM SHALL STAND, UNALTERED, FOR 24 HOURS WITH NO
MORE THAN A +/-ONE POUND PRESSURE CHANGE FROM 300 PSIG,
MEASURED WITH THE SAME GAUGE.
5.508.2.6 EVACUATION
THE SYSTEM SHALL BE EVACUATED AFTER PRESSURE TESTING AND
PRIOR TO CHARGING.
5.508.2.6.1 FIRST VACUUM
PULL A SYSTEM VACUUM DOWN TO AT LEAST 1000 MICRONS (+/-50
MICRONS), AND HOLD FOR 30 MINUTES.
5.508.2.6.2 SECOND VACUUM
PULL A SECOND SYSTEM VACUUM TO A MINIMUM OF 500 MICRONS
AND HOLD FOR 30 MINUTES.
5.508.2.6.3 THIRD VACUUM
PULL A THIRD VACUUM DOWN TO A MINIMUM OF 300 MICRONS, AND
HOLD FOR 24 HOURS WITH A MAXIMUM DRIFT OF 100 MICRONS OVER
A 24-HOUR PERIOD.
5.508.1 OZONE DEPLETION AND GREENHOUSE GAS REDUCTIONS
INSTALLATIONS OF HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT
SHALL COMPLY WITH SECTIONS 5.508.1.1 AND 5.508.1.2.
5.508.1.1 CHLOROFLUOROCARBONS (CFCS)
INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT
DO NOT CONTAIN CFCS.
5.508.1.2 HALONS
INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT
DO NOT CONTAIN HALONS.
5.508.2 SUPERMARKET REFRIGERANT LEAK REDUCTION
NEW COMMERCIAL REFRIGERATION SYSTEMS SHALL COMPLY WITH THE
PROVISIONS OF THIS SECTION WHEN INSTALLED IN RETAIL FOOD STORES 8,000
SQUARE FEET OR MORE CONDITIONED AREA, AND THAT UTILIZE EITHER
REFRIGERATED DISPLAY CASES, OR WALK-IN COOLERS OR FREEZERS
CONNECTED TO REMOTE COMPRESSOR UNITS OR CONDENSING UNITS. THE
LEAK REDUCTION MEASURES APPLY TO REFRIGERATION SYSTEMS CONTAINING
HIGH-GLOBAL-WARMING POTENTIAL (HIGH-GWP) REFRIGERANTS WITH A GWP
OF 150 OR GREATER. NEW REFRIGERATION SYSTEMS INCLUDE BOTH NEW
FACILITIES AND THE REPLACEMENT OF EXISTING REFRIGERATION SYSTEMS IN
EXISTING FACILITIES.
EXCEPTION:REFRIGERATION SYSTEMS CONTAINING LOW-GLOBAL WARMING
POTENTIAL (LOW-GWP) REFRIGERANT WITH A GWP VALUE LESS THAN 150 ARE
NOT SUBJECT TO THIS SECTION. LOW -GWP REFRIGERANTS ARE NONOZONE-
DEPLETING REFRIGERANTS THAT INCLUDE AMMONIA, CARBON DIOXIDE (CO2),
AND POTENTIALLY OTHER REFRIGERANTS.
5.508.2.1 REFRIGERANT PIPING
PIPING COMPLIANT WITH THE CALIFORNIA MECHANICAL CODE SHALL BE
INSTALLED TO BE ACCESSIBLE FOR LEAK PROTECTION AND REPAIRS. PIPING
RUNS USING THREADED PIPE, COPPER TUBING WITH AN
5.508 OUTDOOR AIR QUALITY
5.504.4.3.1 AEROSOL PAINTS AND COATINGS
AEROSOL PAINTS AND COATINGS SHALL MEET THE PWMIR LIMITS FOR ROC IN
SECTION 94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON
USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN
SECTIONS 94522(C)(2) AND (D)(2) OF CALIFORNIA CODE OF REGULATIONS, TITLE
17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER THE JURISDICTION
OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT ADDITIONALLY COMPLY
WITH THE PERCENT VOC BY WEIGHT OF PRODUCT LIMITS OF REGULATION 8 RULE
49.
5.504.4.3.2 VERIFICATION
VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE
REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS
NOT LIMITED TO, THE FOLLOWING:
1. MANUFACTURER’S PRODUCT SPECIFICATION
2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS
5.504.4.6 RESILIENT FLOOR SYSTEMS
WHERE RESILIENT FLOORING IS INSTALLED, AT LEAST 80% OF FLOOR
AREA RECEIVING RESILIENT FLOORING SHALL MEET THE
REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH,
"STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE
ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING
ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION
TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350).
SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR
CERTIFICATION PROGRAMS AND TESTING LABS.
https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.asp
x#material
5.504.4.6.1 VERIFICATION OF COMPLIANCE
DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT RESILIENT
FLOORING MATERIALS MEET THE POLLUTANT EMISSION LIMITS.
5.504.5.3 FILTERS
IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY
OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR
OUTSIDE AND RETURN AIR THAT PROVIDES AT LEAST A MINIMUM
EFFICIENCY REPORTING VALUE (MERV) OF 8. MERV 8 FILTERS SHALL BE
INSTALLED PRIOR TO OCCUPANCY, AND RECOMMENDATIONS FOR
MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED
IN THE OPERATION AND MAINTENANCE MANUAL.
EXCEPTION:EXISTING MECHANICAL EQUIPMENT.
5.504.5.3.1 LABELING
INSTALLED FILTERS SHALL BE CLEARLY LABELED BY THE
MANUFACTURER INDICATING THE MERV RATING.
5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL
WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT
SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES
AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY
PROHIBITED BY OTHER LAWS OR REGULATIONS; OR AS ENFORCED BY
ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY AND
COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA
STATE UNIVERSITY, OR CAMPUS OF THE UNIVERSITY OF CALIFORNIA,
WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR
POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING
OCCUPANTS OF THE PROHIBITIONS.
9/13/24
PF
UP
EXISTING 1 HR SHAFT ENCLOSURE
(ASSUMED, VIF)
EGRESS PATH, SEE TABLE FOR
CALCULATED DISTANCES
NUMBER OF OCCUPANTS EXITING SPACE
COMBINED OCCUPANT COUNT ALONG P.O.T.
(X)
[X]
CA EXISTING BUILDING CODE - 503.1
ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH
REQUIREMENTS OF CBC AS APPLICABLE, FOR NEW CONSTRUCTION.
ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS
NOT LESS COMPLYING WITH WITH THE PROVISIONS OF THE CBC THAN THE
EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION
USE AND OCCUPANCY CLASSIFICATION (CHAPTER 3)
EXISTING: BUSINESS GROUP B OCCUPANCY
PROPOSED: BUSINESS GROUP B OCCUPANCY
ASSEMBLY GROUP A-3 OCCUPANCY (BRIEFING ROOM ONLY)
GENERAL BUILDING HEIGHTS AND AREAS (CHAPTER 5)
CONSTRUCTION TYPE: VB (NO CHANGE)
EXISTING BUILDING HEIGHT: 35' (NO CHANGE)
ALLOWED BUILDING HEIGHT: 60' (A GOVERNS, WITHOUT AREA INCREASE)
EXISTING NUMBER OF STORIES: 2 (NO CHANGE)
ALLOWED NUMBER OF STORIES 2 (A GOVERNS, WITHOUT AREA INCREASE)
ALLOWABLE AREA OF EACH STORY (MIXED OCCUPANCY 506.2.2)
1ST FLOOR: 5,586 SF EXISTING/PROPOSED (NO CHANGE, B & A-3 OCCUPANCY)
6,000 SF ALLOWABLE (SM, A-3 GOVERNS WITH HEIGHT INCREASE)
2ND FLOOR: 5,335 SF EXISTING/PROPOSED (NO CHANGE, B OCCUPANCY)
6,000 SF ALLOWABLE (SM, A-3 GOVERNS WITH HEIGHT INCREASE)
TYPES OF CONSTRUCTION (CHAPTER 6)
NO FIRE RATINGS REQUIRED IN VB CONSTRUCTION PER TABLE 601
FIRE PROTECTION AND LIFE SAFETY SYSTEMS (CHAPTER 9)
FULLY SPRINKLERED
MEANS OF EGRESS (CHAPTER 10)
OCCUPANT LOAD OF AREA OF WORK (TABLE 1004.5)
SEE SCHEDULE BELOW
MEANS OF EGRESS SIZING
SEE PLAN
NUMBER OF EXITS
EXISTING: 2
REQUIRED: 2
EXIT CONFIGURATION (1007.1.1)
MAX DIAGONAL: SEE PLAN
REQ'D SEPARATION: 1/3 DIAGONAL, 1007.1.1 EXCEPTION 2
PROPOSED SEPARATION: SEE PLAN
EXIT ACCESS TRAVEL DISTANCE:
MAX TRAVEL DISTANCE: 250 FT (TABLE 1017.2, SPRINKLERED A GOVERNS)
COMMON PATH OF TRAVEL
MAXIMUM: 75 FT (TABLE 1006.2.1, SPRINKLERED A GOVERNS)
EXIT DISCHARGE
ACCESS TO PUBLIC WAY: SEE SITE PLAN
AREAS OF ASSISTED RESCUE PROVIDED: SEE SITE PLAN
PLUMBING FIXTURE CALCULATIONS (CPC 422.1)
OCCUPANTS BY OCCUPANCY (PER CPC TABLE 4-1, SEE OCCUPANCY TABLE BLW)
B: 114 OCCUPANTS (57 MALE, 57 FEMALE)
A-3: 27 OCCUPANTS (13 MALE, 14 FEMALE)
WATER CLOSETS REQUIRED
B MALE (2:51-100): 1.14 B FEMALE (4: 51-100): 3.14
A-3 MALE (1:1-100): 0.13 A-3 FEMALE (1:1-25): 0.56
MALE TOTAL REQ'D: 1.27 = 2 FEMALE TOTAL REQ'D: 3.7 = 4
MALE PROVIDED: 3 FEMALE PROVIDED: 4
URINAL REQUIRED
B MALE (1:1-100): 0.57
A-3 MALE (1:1-100): 0.13
MALE TOTAL REQ'D: 0.70 = 1
MALE PROVIDED: 1
LAVATORIES REQUIRED
B MALE (1:1-75): 0.76 B FEMALE (2:51-100): 1.14
A-3 MALE (1:200): 0.07 A-3 FEMALE (1:100): 0.14
MALE TOTAL REQ'D: 0.83 = 1 FEMALE TOTAL REQ'D: 1.28 = 2
MALE PROVIDED: 2 FEMALE PROVIDED: 3
DRINKING FOUNTAINS REQUIRED
B (1:150): 0.76
A-3 (1:250): 0.11
TOTAL REQ'D: 0.87 = 1
TOTAL PROVIDED: 2
SERVICE SINK REQUIRED 1
SERVICE SINK PROVIDED 2
806 SF
BRIEFING ROOM
137 SF
STORAGE
1848 SF
OPEN OFFICE
123 SF
ELECTRICAL126 SF
MEETING
86 SF
OFFICE
74 SF
ELEVATOR
260 SF
VESTIBULE
151 SF
NORTH STAIR
354 SF
SHARED OFFICE 149 SF
OFFICE
238 SF
STORAGE
160 SF
EQUIPMENT
151 SF
SOUTH STAIR
125 SF
OFFICE
240 SF
BREAK ROOM
131 SF
HALL
17 SF
JAN
76 SF
MEN
66 SF
WOMEN
[ 108 ]
[
6
0
]
[ 13 ]
[
5
5
]
[ 84 ][ 29 ]
OCCUPANCY GROUP LEGEND
A-3 B
( 5 )
( 1 )
[ 2 ]
( 1 )
[ 2 ]
( 9 )
( 1 )
(
1
)
(
1
)
(
1
)
43 SF
HALL
[ 19 ]
(
1
)
[ 2 ]
[
3
2
]
[
3
3
]
[
1
0
]
(
1
7
)
103 SF
STORAGE
( 7 )( 6 )
( 2 )(E) FIRE
EXTINGUISHER
CABINET
(E) FIRE
EXTINGUISHER
CABINET
679 SF
CONFERENCE ROOM 171 SF
STORAGE
85 SF
IT
369 SF
HALL / FLEX SPACE
133 SF
MEETING ROOM
134 SF
OFFICE
129 SF
OFFICE
244 SF
BREAK ROOM
266 SF
OFFICE
150 SF
MEN'S
183 SF
WOMENS
262 SF
BREAK ROOM
165 SF
EXIT ACCESS
STAIRWAY
43 SF
SHAFT
452 SF
OFFICE
265 SF
ADMIN
155 SF
OFFICE
139 SF
OFFICE
89 SF
ELEV MECH
137 SF
COPY
277 SF
HALL / FLEX SPACE
77 SF
ELEVATOR
154 SF
EXIT ACCESS
STAIRWAY
129 SF
OFFICE
132 SF
OFFICE
16 SF
JAN[ 60 ]
[ 55 ]
CLR
44 3/4"
44" MIN CLR
(CBC 1011.2)
44" MIN CLR
(CBC 1011.2)
44 1/2"
(
9
)
(
1
)
(
1
)( 17 )(
2
)
( 1 )
(
1
)
( 1 )
( 1 )
( 1 )
(
1
8
)
( 2 )( 2 )( 2 )( 1 )( 1 )
200 SF
HALL
106'
- 1" MAX
DIAGONAL
75' - 5" EXIT SEPARATION
92 SF
HALL
( 1 )
(
2
3
)
(
2
3
)
( 3 )[ 2 ][ 4 ](
2
)
(
1
)
(
1
)
[
6
]
[
6
]
[
3
0
]
[
2
9
]
[ 30 ]
[ 33 ]
CLR
2' - 2 5/8"
(E) FIRE
EXTINGUISHER
CABINET
(N) FIRE
EXTINGUISHER
CABINET
(N) FIRE
EXTINGUISHER
CABINET
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
CO
D
E
A
N
A
L
Y
S
I
S
G-401
JH
JR
6/20/24
JR
FIRST FLOOR OCCUPANCY CALCULATIONS SECOND FLOOR OCCUPANCY CALCULATIONS
LEGEND
AREA NAME AREA
NET /
GROSS
OCCUPANCY PLUMBING FIXTURE CALC MAX. OCC. LOAD FOR
ONE EXIT (2022 CBC
TABLE 1006.2.1)
EXITS
REQ'DTYPE FUNCTION OF SPACE (2022 CBC TABLE 1004.5)
LOAD
FACTOR
OCC
LOAD
LOAD
FACTOR OCC LOAD
ELEVATOR 74 SF B (none)49 1
HALL 131 SF B (none)49 1
HALL 43 SF B (none)49
MEN 76 SF B (none)49 1
NORTH STAIR 151 SF B (none)49 1
SOUTH STAIR 151 SF B (none)49 1
WOMEN 66 SF B (none)49 1
(none): 7 0 0
ELECTRICAL 123 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
300 1 300 1 49 1
EQUIPMENT 160 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
300 1 300 1 49 1
JAN 17 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
300 1 300 1 49 1
STORAGE 137 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
300 1 300 1 49 1
STORAGE 238 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
300 1 300 1 49 1
STORAGE 103 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
300 1 300 1 49 1
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM: 6 6 6
BREAK ROOM 240 SF NET B ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED (TABLE AND CHAIRS)
15 17 30 9 49 1
BRIEFING
ROOM
806 SF NET A-3 ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED (TABLE AND CHAIRS)
15 54 30 27 49 2
MEETING 126 SF NET B ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED (TABLE AND CHAIRS)
15 9 30 5 49 1
ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS): 3 80 41
OFFICE 86 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
OFFICE 149 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
OFFICE 125 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
OPEN OFFICE 1848 SF GROSS B BUSINESS AREAS 150 13 150 13 49 1
VESTIBULE 260 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1
BUSINESS AREAS: 5 18 18
SHARED
OFFICE
354 SF SEE
SECTION
1004.8
B CONCENTRATED BUSINESS USE AREAS 49 1
CONCENTRATED BUSINESS USE AREAS: 1 0 0
CODE ANALYSIS (CBC 2022)
COMMON PATH FIRST FLOOR 51' - 4"
NORTH STAIR - MAX TRAVEL 154' - 4"
SOUTH STAIR - MAX TRAVEL 146' - 5"
A.L.S. NOTES
FUNCTION OF SPACE AREA SF/OCCUPANT OCCUPANT LOAD
BRIEFING ROOM 806 SF @ 15 SF/OCC 54 OCC
CONFERENCE ROOM 679 SF @ 15 SF/OCC 46 OCC
MEETING (1ST FLOOR) 126 SF @ 15 SF/OCC 9 OCC
MEETING (2ND FLOOR) 133 SF @ 15 SF/OCC 9 OCC
ASSITIVE LISTENING DEVICES
CBC SECTION 11B-219
1. PROVIDE PERSONAL RECEIVERS FOR 5 PEOPLE (4% OF TOTAL NUMBER
OF SEATS) WITH HEARING IMPAIRMENTS
2. 2 SYSTEMS TO BE HEARING AID COMPATIBLE (25% OF SYSTEMS)
3. SYSTEMS TO BE PORTABLE
4. DEVICES TO BE PROVIDED BY OWNER. CONTRACTOR TO PROVIDE ALL
SIGNAGE
AREA NAME AREA
NET /
GROSS
OCCUPANCY PLUMB FIXT CALC MAX. OCC. LOAD FOR
ONE EXIT (2022 CBC
TABLE 1006.2.1)
EXITS
REQ'DTYPE FUNCTION OF SPACE (2022 CBC TABLE 1004.5)
LOAD
FACTOR
OCC
LOAD
LOAD
FACTOR
OCC
LOAD
ELEVATOR 77 SF B (none)49 1
EXIT ACCESS
STAIRWAY
165 SF B (none)49 1
EXIT ACCESS
STAIRWAY
154 SF B (none)49 1
HALL 200 SF B (none)49
HALL 92 SF B (none)49 1
MEN'S 150 SF B (none)49 1
SHAFT 43 SF B (none)49 1
WOMENS 183 SF B (none)49 1
(none): 8 0 0
ELEV MECH 89 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1
IT 85 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1
JAN 16 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1
STORAGE 171 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM: 4 4 4
BREAK ROOM 244 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE
AND CHAIRS)
15 17 30 9 49 1
BREAK ROOM 262 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE
AND CHAIRS)
15 18 30 9 49 1
CONFERENCE
ROOM
679 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE
AND CHAIRS)
15 46 30 23 49 1
MEETING
ROOM
133 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE
AND CHAIRS)
15 9 30 5 49 1
ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS): 4 90 46
ADMIN 265 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1
COPY 137 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
HALL / FLEX
SPACE
369 SF GROSS B BUSINESS AREAS 150 3 150 3 49 1
HALL / FLEX
SPACE
277 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1
OFFICE 134 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
OFFICE 129 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
OFFICE 266 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1
OFFICE 452 SF GROSS B BUSINESS AREAS 150 4 150 4 49 1
OFFICE 155 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1
OFFICE 139 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
OFFICE 129 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
OFFICE 132 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1
BUSINESS AREAS: 12 21 21
115 71
5 5
5 5
109 70 1
9/13/24
NOTE:
1. THE REQUIRED CLEAR FLOOR SPACE MAY NOT OVERLAP THE REQUIRED
KNEE SPACE BY MORE THAN 19".
2. KNEE CLEARANCES AT TABLES, COUNTERS & WORKSURFACES IS AT LEAST
27" HIGH, 30" WIDE AND 19" DEEP.
REF: 2022 CBC 11B-306
PLANELEVATION
29
"
M
I
N
.
8" MIN.
27
"
M
I
N
.
11" MIN.6" MIN.
9"
M
I
N
.
30" MIN.
48
"
M
I
N
.
C
L
R
.
25
"
M
A
X
.
17
"
M
I
N
.
PULL SIDE
PUSH SIDE
* 48" MIN. CLR. IF
DOOR HAS BOTH
A LATCH AND A
CLOSER
H)
J,K)24" MIN.
24" MIN.
REF: 2022 CBC 11B-404.2.4
44
"
M
I
N
.
C
L
R
.
60
"
M
I
N
.
C
L
R
.
PULL SIDE
PUSH SIDE
* 48" MIN. CLR. IF
DOOR HAS BOTH
A LATCH AND A
CLOSER
F,G)
D)
REF: 2019 CBC 11B-404.2.4
44
"
M
I
N
.
C
L
R
.
60
"
M
I
N
.
C
L
R
.
36" MIN. CLR.
22" MIN.
PUSH SIDE
PULL SIDE
*PROVIDE THIS ADDITIONAL
SPACE IF DOOR IS
EQUIPPED WITH BOTH A
LATCH AND A CLOSER
B,C)
A)
NOTE:
ALL DOORS IN ALCOVES
SHLAL COMPLY WITH THE
CLEARANCES FOR FRONT
APPROACHES
REF: 2022 CBC 11B-404.2.4
48
"
M
I
N
.
C
L
R
.
60
"
M
I
N
.
C
L
R
.
AT EXTERIOR SIDE OF EXTERIOR DOORS
24" MIN. CLR.
AT INTERIOR DOORS
18" MIN. CLR.
12" MIN.
CLR.
12"
CLR.
12"
60 INCHES DIAMETER SPACE MINIMUM CLEAR WIDTH
T-SHAPED SPACE FOR 180 DEGREE TURNS
60" MIN. CLR. DIA.
REF: 2022 CBC 11B-304 &
11B-403.5.1
36
"
M
I
N
.
C
L
R
.
CL
R
.
24
"
M
I
N
.
60
"
M
I
N
.
C
L
R
.
CONT. POINT
24" MAX.
32
"
M
I
N
.
C
L
R
.
36
"
M
I
N
.
C
L
R
.
MIN. 30" X 48"
CLEAR SPACE FOR
FRONT APPROACH
27
"
M
I
N
.
C
L
R
.
KN
E
E
C
L
E
A
R
A
N
C
E
28
"
T
O
3
4
"
M
A
X
.
TA
B
L
E
O
R
C
O
U
N
T
E
R
H
E
I
G
H
T
19" MIN. DEPTH
KNEE/TOE CLEARANCE
4 8 " M I N .
C L R .
30" MIN.CLR.
NOTE:
1. THE REQUIRED CLEAR FLOOR SPACE MAY NOT OVERLAP THE REQUIRED
KNEE SPACE BY MORE THAN 19".
2. KNEE CLEARANCES AT TABLES, COUNTERS & WORKSURFACES IS AT LEAST
27" HIGH, 30" WIDE AND 19" DEEP.
NOTE:
DOOR CLOSERS IF PRESENT, MUST BE SET
SO THAT IT TAKES DOOR AT LEAST 5
SECONDS TO CLOSE FROM AN OPEN
POSITION OF 90 DEGREES TO WITHIN 12° OF
LATCH. THE FORCE TO OPEN DOOR SHALL
NOT EXCEED 5 LBS. TYPICAL.
DOOR CLOSERS
ACCEPTABLE DOOR
HARDWARE AND
MOUNTING HEIGHTS
PANIC
LOOP
LEVER
12.00°
REF: 2022 CBC 11B-404.2
34
"
-
4
4
"
A
.
F
.
F
.
KICK PLATE
NOTE:
SWINGING DOOR & GATE SURFACES WITHIN 10" OF FINISH FLOOR SHALL HAVE
A SMOOTH SURFACE OF THE PUSH SIDE EXTENDING THE FULL WIDTH OF
DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS SHALL
BE WITHIN 1/16" OF SURFACE & SHALL BE FREE OF SHARP OR ABRASIVE
EDGES. CAVITIES CREATED BY KICK PLATES SHALL BE CAPPED.
F.F.
REF: 2022 CBC 11B-404.2.10
10
"
M
I
N
.
15
"
M
I
N
.
48
"
M
A
X
.
48
"
M
A
X
.
44
"
M
A
X
.
20" MAX.
20 < X ≤ 25 MAX.
UNOBSTRUCTED FORWARD REACH
OBSTRUCTED HIGH FORWARD REACH
REF: 2019 CBC 11B-308.2
15
"
M
I
N
.
48
"
M
A
X
.
48
"
M
A
X
.
46
"
M
A
X
.
10" MAX.
10 < X ≤ 24 MAX.
UNOBSTRUCTED SIDE REACH
OBSTRUCTED HIGH SIDE REACH
10" MAX.
34
"
M
A
X
.
34
"
M
A
X
.
REF: 2019 CBC 11B-308.3
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
A
C
C
E
S
S
I
B
I
L
I
T
Y
D
E
T
A
I
L
S
G-902
JH
JR
6/20/24
JR
SCALE: 3" = 1'-0"G-902
TOE & KNEE CLEARANCES33
SCALE: 1/2" = 1'-0"G-902
LATCH APPROACH CLEARANCES23
SCALE: 1/2" = 1'-0"G-902
HINGE APPROACH CLEARANCES32
SCALE: 1/2" = 1'-0"G-902
FRONT APPROACH CLEARANCES31
SCALE: 3/8" = 1'-0"G-902
TURNING SPACE22
SCALE: 3" = 1'-0"G-902
COUNTERTOP CLEARANCES21
SCALE: 1" = 1'-0"G-902
ACC. DOOR REQUIREMENTS11
SCALE: 1" = 1'-0"G-902
ACC. DOOR KICK PLATE12
SCALE: 1/2" = 1'-0"G-902
ACC. FORWARD REACH44
SCALE: 1/2" = 1'-0"G-902
ACC. SIDE REACH42
1
9/13/24
GRAPHICS
Every exit sign and directional exit sign shall have plainly legible letters not less
than 6 inches (152 mm) high with the principal strokes of the letters not less than
3/4 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not
less than 2 inches (51 mm) wide, except the letter "I," and the minimum spacing
between letters shall be not less than 3/8 inch (9.5 mm). Signs larger than the
minimum established in this section shall have letter widths, strokes and spacing
in proportion to their height.
The word "EXIT" shall be in high contrast with the background and shall be clearly
discernible when the means of exit sign illumination is or is not energized. If a
chevron directional indicator is provided as part of the exit sign, the construction
shall be such that the direction of the chevron directional indicator cannot be
readily changed.
6"
M
I
N
H
E
I
G
H
T
3/8" MIN. SPACING
3/4" MIN. STROKE
(EXCEPT FOR LETTER "I")
2" MIN. LETTER WIDTH
CBC 1013.6.1
INTERNALLY ILLUMINATED SIGNS
Electrically powered, self-luminous and photoluminescent exit signs shall
be listed and labeled in accordance with UL 924 and shall be installed in
accordance with the manufacturer's instructions and Chapter 27. Exit signs
shall be illuminated at all times.
CBC 1013.5
EXTERNALLY ILLUMINATED EXIT SIGNS
Externally illuminated exit signs shall comply with Sections 1013.6.1
through 1013.6.3.
CBC 1013.6
WHERE REQUIRED
Exits and exit access doors shall be marked by an approved exit sign readily
visible from any direction of egress travel. The path of egress travel to exits and
within exits shall be marked by readily visible exit signs to clearly indicate the
direction of egress travel in cases where the exit or the path of egress travel is not
immediately visible to the occupants. Intervening means of egress doors within
exits shall be marked by exit signs. Exit sign placement shall be such that any
point in an exit access corridor or exit passageway is within 100 feet (30 480 mm)
or the listed viewing distance of the sign, whichever is less, from the nearest
visible exit sign.
EXCEPTIONS:
1. Exit signs are not required in rooms or areas that require only one exit or
exit access.
2. Main exterior exit doors or gates that are obviously and clearly identifiable
as exits need not have exit signs where approved by the building official.
3. Exit signs are not required in occupancies in Group U and individual
sleeping units or dwelling units in Group R-1, R-2 or R-3 or R-3.1.
4. Exit signs are not required where inmates are housed, or held in
dayrooms, sleeping rooms or dormitories in occupancies in Group I-3.
5. In occupancies in Groups A-4 and A-5, exit signs are not required on the
seating side of vomitories or openings into seating areas where exit signs
are provided in the concourse that are readily apparent from the
vomitories. Egress lighting is provided to identify each vomitory or
opening within the seating area in an emergency.
CBC 1013.1
DIRECTIONAL CHEVRON
SHALL NOT BE READILY
CHANGED.
REFER TO CODE PLAN
FOR INDICATED
DIRECTION
ROOM ID
DEPTH:
RAISED 1/32" MIN. ABOVE
BACKGROUND
CHARACTERS:
UPPERCASE, SANSERIF, NOT
ITALIC, WIDTH OF "0" SHALL BE
60% MIN. TO 110% MAX. OF "1"
HEIGHT:
ROOM ID TEXT TO BE 1" HIGH,
TYP.
STROKE:
THICKNESS OF "1" SHALL BE 15%
MAX. OF HEIGHT
3/8" MIN., 1/2" MAX.
CORRESPONDING GRADE II
BRAILLE
NOTE:
PERMANENT SIGNAGE TO BE
INSTALLED ON THE WALL
ADJACENT TO THE LATCH
SIDE OF THE DOOR.
MOUNTING LOCATION MUST
ALLOW A PERSON TO
APPROACH WITHOUT
ENCOUNTERING PROTRUDING
OBJECTS OR STANDING
WITHIN THE SWING PATH OF
THE DOOR.
60
"
M
A
X
.
18 74
CHARACTER SPACING
WIDTH MAX. RECTANGULAR
1/8" MIN. TO 4 TIMES STROKE
STROKE WIDTH MAX.
1/16" MIN. TO 4 TIMES
NON RECTANGULARRECTANGULAR
ROOM
48
"
M
I
N
.
18" SQ. CLR. FLOOR AREA
CENTERED ON SIGN &
CLEAR OF DOOR SWING
INSTALLATION, HEIGHT AND LOCATION
RAISED CHARACTERS
REF: 2019 CBC 11B-703
EXIT
EXIT SIGNAGE
3/
8
"
M
I
N
.
DEPTH:
RAISED 1/32" MIN. ABOVE
BACKGROUND
CHARACTERS:
UPPERCASE, SANSERIF, NOT
ITALIC, WIDTH OF "0" SHALL BE
60% MIN. TO 110% MAX. OF "1"
HEIGHT:
TEXT TO BE 1" HIGH,
TYP.
STROKE:
THICKNESS OF "1" SHALL BE 15%
MAX. OF HEIGHT
3/8" MIN., 1/2" MAX.
8"
4"
4"
6"
NOTE : REFER TO SHEET A-601
AND DOOR SCHEDULE FOR
ROOM SIGN DESIGNATIONS
AND LOCATION
SYMBOL PROPORTIONS
FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL
REF 11B-703.7.2.1
REF: CBC 1004.9
ALL TEXT/GRAPHICS TO BE A
PERMANENT PART OF THE SIGN
FOR ROOM SIGN REQUIREMENTS
PLAN FOR LOCATION
MAXIMUM
OCCUPANCY
0'
-
7
"
0' - 10"
59
0'
-
1
"
0'
-
1
"
0'
-
0
1
/
2
"
1/2" RADIUS, TYP.
1" HIGH TEXT, CHARACTERS
SPACED 1/2" APART
2" HIGH TEXT, VERIFY MESSAGE
PRIOR TO FABRICATION
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
A
C
C
E
S
S
I
B
I
L
I
T
Y
D
E
T
A
I
L
S
G-903
JH
JR
6/20/24
JR
SCALE: 1" = 1'-0"G-903
ACC. ILLUMINATED EXIT SIGN14
SCALE: 3" = 1'-0"G-903
ACC. ROOM SIGNAGE12
SCALE: 3" = 1'-0"G-903
INTL SYMBOL OF ACC.22
SCALE: 3" = 1'-0"G-903
MAX. OCCUPANT LOAD23
9/13/24
NOTES:
1. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE
LAVATORIES SHALL BE INSULATED OR OTHERWISE
COVERED. THERE SHALL BE NO SHARP OR ABRASIVE
SURFACES UNDER LAVATORIES.
2. THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN
DETERMINING KNEE & TOE CLEARANCES.
3. SINK SHALL BE 6-1/2" DEEP MAX.
4. OPERABLE PARTS OF SOAP OR OTHER DISPENSERS
LOCATED ON THE BACK WALL OF THE LAVATORY ARE WITHIN
REACH RANGE 40Ffl MAXIMUM AFF AND 17fl-19fl MAXIMUM
DEEP DEPENDENT UPON TOE CLEARANCE BELOW PER CBC.
5. DISPENSERS MOUNTED ON THE GRAB BAR SIDE OF
ACCESSIBLE TOILET SHALL NOT PROJECT MORE THAN 3-1/2"
FROM FACE OF WALL, NOR BE LOCATED CLOSER THAN 1-1/2"
CLEAR OF BOTTOM OF GRAB BAR.
FAUCET ACCESSIBILITY NOTES:
(CONTROLS FOR FAUCETS SHALL COMPLY WITH CBC 11B-309)
1. FAUCETS CONTROLS AND OPERATING MECHANISMS SHALL
BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE
TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST.
2. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE
NO GRATER THAN 5 POUND FORCE (22.2N). LEVER-
OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED
MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS.
SELF-CLOSINGVALVES ARE ALLOWED IF THE FAUCET
REMAINS OPEN FOR AT LEAST 10 SECONDS.
P
FF
F
I
R
E
E
X
T
I
N
G
U
I
S
H
E
R
M
FF
J
K
ELEVATION 30" MIN
48
"
M
I
N
FORWARD
APPROACH CLEAR
FLOOR SPACE
PLAN
FLUSH VALVE
TOP OF BOWL
13
1
/
2
M
I
N
.
MIRROR
SEAT COVER
DISPENSER
SANITARY NAPKIN
DISPENSER
TOWEL
DISPENSER
ELECTRIC
DRYER
TRASH
RECEPTACLE
CUP
DISPENSER
P
F.F.
REF. 11B-603.3-.5
F E
SIDE GRAB BAR
TOILET
PAPER DISP.
C
D1
12" MAX.42" MIN.
IN FRONT OF TOILET
24" MIN.
D2
54" MIN.
A
FINISHED
WALL
SIDE VIEW
PLAN VIEW
30
"
M
I
N
.
REQUIRED
CLEAR SPACE
F.O.F.
18" MIN. CLR.
48" MIN.
G
9" MIN. CLR.
TOE CLR.
6" MAX.
17" MIN.
8" MIN. KNEE CLR.
REQUIRED
CLEAR SPACE
REMOVABLE CABINET
FACE (WHERE OCCURS)
H
EXTEND FINISHED
FLOOR TO WALL
H
*FRONT OF THE HIGHER OF THE
RIM OR COUNTER SURFACE
(CBC 11B-606.3)
REAR GRAB BAR
6"12"24"
36" MIN.
G
FINISHED
WALL
L
FIRE EXTINGUISHER DRINKING FOUNTAIN
DOOR-MOUNTED SIGNAGE (TYP.)
PICTOGRAMS AND/OR LETTERING ARE NOT REQUIRED ON DOOR-MOUNTED SIGNAGE
12"
12"
CL
WOMEN
MEN
UNISEX
12"
12"
DIAMETER
CENTER
LINE OF SIGN
CENTER
LINE OF DOOR AT
EITHER SIDE
WITHIN 1"12" MAX.
42" MIN.
54" MIN.
48" MIN.
18" MIN.
18" MIN 32" MIN CLR
60" MIN.
12" M
AX
30"x48"
CLEAR
FLOOR
LANDING
6 0 " M I N . C L R .
17" MIN.-18" MAX.
FLUSH
ACTIVATOR
ON TRANSFER
SIDE
REF 2022 CBC 11B-604
19" MAX WALL FRAMING - REFER TO FLOOR
PLAN FOR WALL TYPES
WALL FINISH - REFER TO FINISH SCHEDULE
CONCEALED FASTENERS. MIN. 6-#
10 WOOD SCREW WITH 1 1/2"
PENETRATION INTO BLOCKING.
1 1/4" MIN. - 2" MAX. DIA.
BLOCKING IN WALL
1 1/2"
12" MIN. TO PROJECTION ABOVE (1/ 1/2"
FOR SHOWER CONTROLS OR GRAB
BARS.)
1 1/2" MIN TO PROJECTION BELOW
SEOR PROVIDE CALCS. TO
JUSTIFY ALL COMPONENTS AND
CONNECTIONS IN THIS DETAIL.
PENETRATION
0' - 1 1/2"
1" MIN.
2
1/4"
WALL MOUNTED SIGNAGE TO BE
LOCATED ON LATCH SIDE OF
DOOR CLEAR OF DOOR SWING.
MOUNT AT 48" MIN AND 60" MAX
FROM THE BASELINE OF THE
HIGHEST LINE OF RAISED
CHARACTERS.
DOOR-MOUNTED
SIGNAGE WITHIN
1" OF
CENTERLINE OF
DOOR
LETTERING
RAISED 1/32"
MIN.
UPPERCASE SANS
SERIF CHARACTERS
HEIGHT OF
LETTERING 5/8" MIN.
TO 2" MAX.
RESTROOM
3/8" MIN., 1/2" MAX.CORRESPONDING
GRADE II BRAILLE
ROOM IDENTIFICATION SIGN
REFER TO ROOM ID SIGN
DETAIL
REF. 11B-703.7.2.6 58" MIN- 60" MAX
UNISEX
RESTROOM
60" MAX.
WALL SIGNAGE
DOOR-MOUNTED GEOMETRIC SYMBOLS
FOR ADDITIONAL GEOMETRIC SYMBOL INFORMATION
REF. TO: 12/G-904
FOR ADDITIONAL ROOM ID SIGN INFORMATION
REF. TO: 12/G-903
A TOILET CL FROM WALL 17"-18"L LOW DRINKING FOUNTAIN
APPROACH
PER 11B-306
B TOILET SEAT HEIGHT 17"-19"SPOUT HEIGHT AND LOCATION
FROM EDGE OF UNIT INCLUDING
BUMPERS
36" MAX. A.F.F & 5"
MAX. FROM FRONT
EDGE OF UNIT
C TOP OF GRAB BAR GRIPPING
SURFACE
33"-36"DRINKING FOUNTAIN OPERABLE
PARTS FROM FRONT EDGE OF
THE UNIT
6" MAX.
D1 FURTHEST TOILET PAPER IN
FRONT OF TOILET
7"-9" AT CL M DRINKING FOUNTAIN KNEE
CLEARANCE
27" MIN. CLR.
D2 DISPENSER HEIGHT 19"-24"
E SANITARY NAPKIN DISPOSAL
(HIGHEST OPERABLE PART A.F.F.)
19" MIN.P DISPENSERS/OPERABLE PARTS 40" MAX.
F MIRROR - BOT. OF REFLECTIVE
SURFACE A.F.F.
40" MAX. WHEN
ABOVE SINK OR
COUNTERTOP
35" MAX. NO LAV.
Q REACH RANGE - FRONT & SIDE
APPROACH
48" MAX.
G LAVATORY/SINK RIM HEIGHT 34" MAX.R BOTTOM OF OPENING/OUTLET 19" MIN.
H LAVATORY KNEE CLEARANCE 17" MIN. AT 8" DEPTH
29" MIN. AT APRON
S TOE CLEARANCE AT TOILET
PARTITION
9" MIN.
J URINAL LIP HEIGHT 17" MAX.T TOILET FLUSH CONTROL HEIGHT
K URINAL FLUSH HANDLE HEIGHT 44" MAX.
STANDARD HEIGHT FOUNTAIN
ACCESSIBLE FOUNTAIN
THE SPOUT SHALL PROVIDE A FLOW OF WATER 2" HIGH MIN. AND SHALL BE LOCATED 5"
MAX. FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE
MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS
ARE LOCATED LESS THAN 2 INCHES FROM THE FRONT OF THE UNIT, THE ANGLE OF THE
WATER STREAM SHALL BE 30 DEGREES MAX. WHERE SPOUTS ARE LOCATED BETWEEN 3
INCHES AND 5 INCHES MAX. FROM THE FRONT ON THE UNIT THE ANGLE OF THE WATER
STREAM SHALL BE 15 DEGREES MAX.
36
"
M
A
X
.
18" MIN. CLR.
5" MAX.
19" MAX.15" MIN
OPERABLE PARTS SHALL
COMPLY WITH 11B-309 THE FLOW
OF WATER SHALL BE ACTIVATED
BY A MANUALLY OPERATED
SYSTEM. FRONT MOUNTED OR
SIDE MOUNTED & LOCATED
WITHIN 6" OF THE FRONT EDGE
OF THE FOUNTAIN OR AN
AUTOMATIC ELECTRONICALLY
CONTROLLED DEVICE.
38
"
M
I
N
.
4
3
"
M
A
X
.
-TOE AND KNEE CLEARANCE SHALL BE
PROVIDED AS PER 11B 306.3 SEE DETAIL
REF 11B 602
-MOUNTING SHALL BE PER MANUF. INTO
SOLID BACKING PLATE
ACCESSIBLE BOTTLE FILLER
WHERE OCCURS. REFER TO
DETAIL REF. TO: 42 / G-904
32" MIN. CLR.
36" MIN. IF ALCOVE
DEPTH IS >24"
18" MIN
ACCESSIBLE WATER
FILLER STATION
OPERABLE PARTS SHALL
COMPLY WITH 11B-309
THE FLOW OF WATER
SHALL BE ACTIVATED BY
A MANUALLY OPERATED
SYSTEM. FRONT
MOUNTED OR SIDE
MOUNTED & LOCATED
WITHIN 6" OF THE FRONT
EDGE OF THE FOUNTAIN
OR AN AUTOMATIC
ELECTRONICALLY
CONTROLLED DEVICE.
REF 11B 602
-MOUNTING SHALL BE
PER MANUFACTURER
INTO SOLID BACKING
PLATE
4" MAX.
30" MIN. CLR. FOR FRONT APPROACH
48
"
M
A
X
.
T
O
S
E
N
S
O
R
EQ
EQ
CL
4 8 " M I N . C L R . F O R F R O N T A P P R O A C H
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
A
C
C
E
S
S
I
B
I
L
I
T
Y
D
E
T
A
I
L
S
G-904
JH
JR
6/20/24
JR
SCALE: 1/2" = 1'-0"G-904
FIXTURE AND ACCESSORIES MOUNTING HEIGHTS AND CLEARANCES51
SCALE: 1 1/2" = 1'-0"G-904
RESTROOM GEOMETRIC SYMBOLS12
SCALE: 1/2" = 1'-0"G-904
ACC. SINGLE ACCOMODATION TOILET31
SCALE: 3" = 1'-0"G-904
ACC. GRAB BAR ATTACHMENT21
SCALE: 1" = 1'-0"G-904
RESTROOM SIGNAGE22
1
SCALE: 3" = 1'-0"G-904
HI-LO DRINKING FOUNTAIN32
SCALE: 3" = 1'-0"G-904
WATER BOTTLE FILLER STATION42
9/13/24
13064
242.79
bld cor
13065
242.81
bld cor
E V
E V
E V
HOSE BIB
PF
SITE PLAN LEGEND
EXISTING CONCRETE PAVING
EXISTING PLANTING AREA
STANDARD ACCESSIBLE STALL
ELECTRICAL VEHICLE CHARGING STALLEV
VAN ACCESSIBLE STALLVAN
ACCESSIBLE PATH OF TRAVEL
(SHALL BE 48" MIN. CBC 11B-403.5)
EASTMENT
SETBACK
PROPERTY LINE
BUILDING FOOTPRINT
1106 WALNUT (EXISTING)
EXISTING 10,921 SF (NO CHANGE)
VB CONSTRUCTION TYPE
2 STORIES
EXISTING PARKING
NO NEW WORK
EXISTING PARKING
NO NEW WORK
02 4013.M
02 4013.BE
02 4013.BF
02 4013.BG
02 4013.U
45' - 1"
EXISTING PARKING
NO NEW WORK
1
02 4013.U
1
EXTERIOR AREA OF ASSISTED
RESCUE PER 1009.7, NO
SEPARATION REQUIRED PER
1009.7.2 EXCEPTION.
FENCE/GATE PROJECT UNDER SEPARATE
PERMIT, SHOWN FOR REFERENCE ONLY
105' - 0"
35' - 2"
70' - 8"
30' - 8"
1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
AR
C
H
I
T
E
C
T
U
R
A
L
S
I
T
E
P
L
A
N
AS-101
JH
JR
6/20/24
JR
KEYNOTES
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS
2. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO ELECTRICAL PLANS FOR FURTHER IINFORMATION.
4. ALL SIDEWALKS, CROSSWALKS, COMMON AREAS AND BUILDING ENTRANCES
SHALL BE ACCESSIBLE AND IN COMPLIANCE WITH 2022 CBC 11B.
A. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP
RESISTANT.
B. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW
PASSAGE OF A SPHERE <1/2".
C. VERTICAL CHANGES IN LEVEL SHALL NOT EXCEED 1/4".
D. THE CLEAR WIDTH FOR SIDEWALKS AND WALKS SHALL BE 48" MIN.
5. ALL CURBING NOT WITHIN A PARKING SPACE SHALL BE PAINTED RED TO
DESIGNATE THE FIRE LANES
SITE PLAN GENERAL NOTES
SCALE: 1/16" = 1'-0"AS-101
SITE PLAN1
W
A
L
N
U
T
S
T
.
SANTA ROSA ST.
02 4013.BE EXISTING ACCESSIBLE PARKING TO REMAIN.
02 4013.BF EXISTING DRIVE APPROACH TO REMAIN.
02 4013.BG EXISTING CURB AND GUTTER.
02 4013.M EXISTING CURB RAMP TO REMAIN.
02 4013.U EXISTING ACCESSIBLE PATH OF TRAVEL TO REMAIN
REQUIRED PARKING
FUNCTION AREA
MIN. REQUIRED
PER....
TOTAL PARKING
REQ'D
TOTAL PARKING
PROVIDED
OFFICE 9,633 1 PER 300 S.F. 33 34
9/13/24
EXISTING STUD FRAMED WALL, TO REMAIN
WALL TYPES LEGEND
A1
A2
EXISTING WALL FURRING, TO REMAINA3
EXISTING MASONRY BLOCK WALL, TO REMAINA4
EXISTING CONCRETE WALL, TO REMAINA5
EXISTING STOREFRONT WALL, TO REMAINA6
NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP.
BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS
A7 EXISTING MASONRY BLOCK WALL, TO REMAIN
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
BUREAU
SERGEANT
107
MEETING
125
OFFICE
124
DRONE/EQUIP.
STORAGE
105
DETECTIVE
EQUIPMENT
106
ELECTRICAL
120
WOMEN
119
MEN
118
HALL
114
JAN.
117
HALL
115
STORAGE
111
STAIR
122
STAIR
123
BRIEFING
ROOM
122
HALL
139
LOBBY
100
ELEV.
127
SHARED
OFFICE
126
A5
A7
A7
A7A7
A7
A7
A2
A3
A2
A2
02 4116.BD
02 4116.J
A2
02 4116.C
02 4116.D
A-401
1
02 4116.CJ
1
02 4116.AS
02 4116.AR
02 4116.CJ
DEMO - INTERIOR - CARPET
DEMO EXISTING PARTITION OR
WALL FINISH
DEMO - INTERIOR -
LINOLEUM TILE
DEMO - INTERIOR - TILE
INTERIOR - CARPET - TO REMAIN
NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS
A-501 & A-502 FOR ADDTIONAL INFORMATION.
DEMO - INTERIOR - LVT
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DE
M
O
L
I
T
I
O
N
F
I
R
S
T
F
L
O
O
R
P
L
A
N
AD-101
JH
JR
6/20/24
JR
KEYNOTES
02 4116.AR PORTION OF EXISTING WALL TO BE REMOVED FOR NEW DOOR
OPENING.
02 4116.AS PREPARE EXISTING OPENING FOR NEW STUD WALL INFILL.
02 4116.BD EXISTING LIGHT GUAGE METAL STUD WALL TO BE REMOVED.
02 4116.C EXISTING CASEWORK TO BE REMOVED
02 4116.CJ EXISTING STOREFRONT TO BE REMOVED AND DISCARDED.
02 4116.D EXISTING COUNTERTOP AND CASEWORK TO BE REMOVED
02 4116.J EXISTING SINK TO BE REMOVED. PROTECT IN PLACE EXISTING
PLUMBING FOR NEW DRINKING FOUNTAIN AND BOTTLE FILLER.
REFER TO PLUMBING FOR ADDITIONAL INFORMATION.
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
FLOOR PLAN GENERAL NOTES
2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED.
3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER
INFORMATION.
4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF
PROVIDED.
5. NOT USED
6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY
NOTED OTHERWISE.
7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS,
SHELVING AND BATHROOM FIXTURES.
8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC
HEIGHT LIMITATIONS
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A
ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO
ROUGH DOOR OPENING
11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE
BARRIERS
12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE
MAINTAINED
13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY
OF PARTITION RATING
SCALE: 3/16" = 1'-0"AD-101
DEMOLITION FIRST FLOOR PLAN1
FLOOR DEMOLITION LEGEND
1
1
9/13/24
UP
EXISTING STUD FRAMED WALL, TO REMAIN
WALL TYPES LEGEND
A1
A2
EXISTING WALL FURRING, TO REMAINA3
EXISTING MASONRY BLOCK WALL, TO REMAINA4
EXISTING CONCRETE WALL, TO REMAINA5
EXISTING STOREFRONT WALL, TO REMAINA6
NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP.
BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS
A7 EXISTING MASONRY BLOCK WALL, TO REMAIN
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
A2
A7
A7
A7
A2
A2
A2
A2
A2
A7
02 4116.CI
02 4116.CA
02 4116.CA
A-401
2
02 4013.AH
02 4013.AH
02 4116.A
02 4116.D
1
1
02 4116.CP
1
DEMO - INTERIOR - CARPET
DEMO EXISTING PARTITION OR
WALL FINISH
DEMO - INTERIOR -
LINOLEUM TILE
DEMO - INTERIOR - TILE
INTERIOR - CARPET - TO REMAIN
NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS
A-501 & A-502 FOR ADDTIONAL INFORMATION.
DEMO - INTERIOR - LVT
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DE
M
O
L
I
T
I
O
N
S
E
C
O
N
D
F
L
O
O
R
P
L
A
N
AD-102
JH
JR
6/20/24
JR
KEYNOTES
02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE.
02 4116.A EXISTING PLUMBING FIXTURE TO BE REMOVED
02 4116.CA DEMO EXISTING GYP. BD. COLUMN WRAP TO PREPARE FOR NEW
WALLS.
02 4116.CI EXISTING MOTORIZED PROJECTOR SCREEN TO BE REMOVED, SET
ASIDE, AND PROTECTED FOR INSTALLATION IN CONFERENCE
ROOM. SEE PROPOSED PLANS.
02 4116.CP REMOVE EXISTING FIRE EXTINGUISHER CABINET, PREPARE
OPENING FOR NEW CABINET
02 4116.D EXISTING COUNTERTOP AND CASEWORK TO BE REMOVED
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
FLOOR PLAN GENERAL NOTES
2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED.
3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER
INFORMATION.
4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF
PROVIDED.
5. NOT USED
6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY
NOTED OTHERWISE.
7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS,
SHELVING AND BATHROOM FIXTURES.
8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC
HEIGHT LIMITATIONS
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A
ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO
ROUGH DOOR OPENING
11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE
BARRIERS
12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE
MAINTAINED
13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY
OF PARTITION RATING
SCALE: 3/16" = 1'-0"AD-102
DEMOLITION SECOND FLOOR PLAN1
FLOOR MATERIALS LEGEND
9/13/24
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
MEETING
125
OFFICE
124
BUREAU
SERGEANT
107
DRONE/EQUIP.
STORAGE
105
DETECTIVE
EQUIPMENT
106
ELECTRICAL
120
WOMEN
119
MEN
118
HALL
114
JAN.
117
HALL
115
STORAGE
111
STAIR
122
STAIR
123
BRIEFING
ROOM
122
HALL
139
LOBBY
100
ELEV.
127
SHARED
OFFICE
126
8' - 0"
8' - 0"
02 4013.BH
02 4013.AH
02 4116.AC
02 4116.AC
02 4116.CD
02 4013.BI
02 4116.AM
02 4116.AC
02 4116.AM
02 4116.CJ
02 4116.I
02 4116.CD
02 4013.BI02 4116.AB
02 4116.AB 02 4116.AD
02 4013.BI
02 4116.AF
02 4116.AB
02 4116.BA
CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X"
LEGEND
LIGHT FIXTURE, REFER TO ELECTRICAL PLANS
MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS
INTERIOR - GYPSUM BOARD CEILING OVER
NEW 2X FRAMING
INTERIOR - ACOUSTIC CEILING TILE
REUSE OR MATCH EXISTING TILE AND GRID
CEILING ACCESS PANEL
DEMOLISHED OBJECTS
MATERIAL TAG
REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION
DEMO - INTERIOR - GYPSUM BOARD CEILING
SEE KEYNOTE
DEMO - INTERIOR - ACOUSTICAL CEILING TILE
SEE KEYNOTE
EXTERIOR - (E) SOFFIT TO REMAIN
ACT-1
ACT-1
GWB-1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DE
M
O
L
I
T
I
O
N
R
E
F
L
E
C
T
E
D
C
E
I
L
I
N
G
P
L
A
N
-
F
I
R
S
T
F
L
O
O
R
AD-111
JH
JR
6/20/24
JR
SCALE: 3/16" = 1'-0"AD-111
DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR
1
KEYNOTES
1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES.
5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH
FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED
CEILING PLAN, UNO.
6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH
FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED
INCLUDING POP RIVETS AND TAPPETS.
7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO
PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS
8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH
CEILING
9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL
SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING
FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN
BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE
VERTICAL STRUTS
RCP GENERAL NOTES
10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE
ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING
LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION.
11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING
ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA.
REFER TO SPECS FOR SHADE CLOTH
02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE.
02 4013.BH EXISTING SOFFIT DROP TO REMAIN.
02 4013.BI EXISTING LIGHT FIXTURE TO BE RELOCATED. REFER TO
ELECTRICAL.
02 4116.AB PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR NEW WALL
INSTALLATION, SET ASIDE GRID AND TILE FOR POTENTIAL REUSE.
02 4116.AC DEMOLISH GRID, REMOVE AND SET ASIDE TILE FOR POTENTIAL
RESUSE.
02 4116.AD PARTIALLY REMOVE SOFFIT AS NEEDED FOR NEW WALL
INSTALLATION.
02 4116.AF MODIFY SOFFIT AS NEEDED FOR PROPOSED SOFFIT EXTENSION.
02 4116.AM EXISTING LIGHT FIXTURE TO BE REMOVED AND DISCAREDED.
REFER TO ELECTRICAL.
02 4116.BA PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR RECESSED
PROJECTION SCREEN INSTALLATION, SET ASIDE GRID AND TILE
FOR POTENTIAL REUSE.
02 4116.CD EXISTING DIFFUSER TO BE REMOVED AND DISCARDED. REFER TO
MECHANICAL.
02 4116.CJ EXISTING STOREFRONT TO BE REMOVED AND DISCARDED.
02 4116.I EXISTING WALL TO BE REMOVED.
9/13/24
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
ADMIN
214A
DEPT.
CHIEF
213
CHIEF
214C
STAIRS
144
INT
AFFAIRS
LIEUT.
224
BREAK
ROOM
207
BOS.
MANAGER
206
PUBLIC
AFFAIRS
MANAGER
205
BREAK
ROOM
215
SERVER
216
WOMENS
222
MENS
129MEETING
ROOM
202
ELEVATOR
131
COPY
ROOM
210
ELEV MECH
112
DEPT.
CHIEF
211
CRIME
ANALYST
209
TRAIN/HIRING
MANAGER
208
EQUIP.
220
1275 SF
CONF.
202
HALL
149
02 4013.AH
02 4116.AC
02 4116.AM
02 4116.AM
02 4116.AB
02 4116.AB
02 4116.CD02 4013.BI
02 4116.AB
02 4116.AB
02 4116.AH 02 4116.CD
02 4116.CD
02 4116.CD
02 4116.BA
02 4116.AB
02 4013.AH
CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X"
LEGEND
LIGHT FIXTURE, REFER TO ELECTRICAL PLANS
MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS
INTERIOR - GYPSUM BOARD CEILING OVER
NEW 2X FRAMING
INTERIOR - ACOUSTIC CEILING TILE
REUSE OR MATCH EXISTING TILE AND GRID
CEILING ACCESS PANEL
DEMOLISHED OBJECTS
MATERIAL TAG
REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION
DEMO - INTERIOR - GYPSUM BOARD CEILING
SEE KEYNOTE
DEMO - INTERIOR - ACOUSTICAL CEILING TILE
SEE KEYNOTE
EXTERIOR - (E) SOFFIT TO REMAIN
ACT-1
ACT-1
GWB-1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DE
M
O
L
I
T
I
O
N
R
E
F
L
E
C
T
E
D
C
E
I
L
I
N
G
P
L
A
N
-
S
E
C
O
N
D
F
L
O
O
R
AD-112
JH
JR
6/20/24
JR
SCALE: 3/16" = 1'-0"AD-112
DEMOLITION REFLECTED CEILING PLAN - SECOND FLOOR
1
KEYNOTES
1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES.
5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH
FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED
CEILING PLAN, UNO.
6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH
FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED
INCLUDING POP RIVETS AND TAPPETS.
7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO
PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS
8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH
CEILING
9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL
SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING
FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN
BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE
VERTICAL STRUTS
RCP GENERAL NOTES
10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE
ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING
LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION.
11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING
ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA.
REFER TO SPECS FOR SHADE CLOTH
02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE.
02 4013.BI EXISTING LIGHT FIXTURE TO BE RELOCATED. REFER TO
ELECTRICAL.
02 4116.AB PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR NEW WALL
INSTALLATION, SET ASIDE GRID AND TILE FOR POTENTIAL REUSE.
02 4116.AC DEMOLISH GRID, REMOVE AND SET ASIDE TILE FOR POTENTIAL
RESUSE.
02 4116.AH MODIFY EXISTING ACT CEILING AS NEEDED FOR REMOVAL OF
RECESSED PROJECTOR SCREEN.
02 4116.AM EXISTING LIGHT FIXTURE TO BE REMOVED AND DISCAREDED.
REFER TO ELECTRICAL.
02 4116.BA PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR RECESSED
PROJECTION SCREEN INSTALLATION, SET ASIDE GRID AND TILE
FOR POTENTIAL REUSE.
02 4116.CD EXISTING DIFFUSER TO BE REMOVED AND DISCARDED. REFER TO
MECHANICAL.
9/13/24
PF
EXISTING STUD FRAMED WALL, TO REMAIN
WALL TYPES LEGEND
A1
A2
EXISTING WALL FURRING, TO REMAINA3
EXISTING MASONRY BLOCK WALL, TO REMAINA4
EXISTING CONCRETE WALL, TO REMAINA5
EXISTING STOREFRONT WALL, TO REMAINA6
NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP.
BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS
A7 EXISTING MASONRY BLOCK WALL, TO REMAIN
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
BUREAU
SERGEANT
107
MEETING
125
OFFICE
124
DRONE/EQUIP.
STORAGE
105
DETECTIVE
EQUIPMENT
106
ELECTRICAL
120
WOMEN
119
MEN
118
HALL
114
JAN.
117
HALL
115
STORAGE
111
STAIR
122
STAIR
123
BRIEFING
ROOM
122
HALL
139
LOBBY
100
ELEV.
127
SHARED
OFFICE
126
A5
A7
A7
A7A7
A7
A7
A1
A1
A2
A3
A2
A2
3
A-200
27 0000.B
27 0000.B
27 0000.B
27 0000.B
08 4313.A
08 4313.A 08 4313.A
A2
A-412
4
S-1 S-1S-1S-1S-1
A-601
1
A-601
2
A-401
4
A-412
3
A-412
2
1
111B
STORAGE
133
A-4111W
A-411
2N
1N
1E
1S
2W
2S
2E
122A
S-2 S-2
122B
OPEN
OFFICE
102
INCIDENT
COM.
123
BREAK
ROOM
121
02 4013.A
114A1
A-601 3
S-3
5
9' - 1"
AL
I
G
N
2'
-
2
"
ALIGN
ALIGN
15' - 5"
A-601
4
A-413
1
2
A1
V.I.F.
7' - 10"
V.I.F.
3' - 3"
V.I.F.
1' - 3"
V.I.F.
6' - 6"
V.I.F.
1' - 2"
V.I.F.
6' - 6"
V.I.F.
9"
V.I.F.
3' - 4"
V.I.F.
1' - 5"
V.I.F.
9' - 11"
1
1
1'
-
0
"
E111A
10 5100.E
1
1
1
126
100A
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
PR
O
P
O
S
E
D
F
I
R
S
T
F
L
O
O
R
P
L
A
N
A-101
JH
JR
6/20/24
JR
KEYNOTES
02 4013.A EXISTING STOREFRONT TO REMAIN. PROTECT IN PLACE
08 4313.A ALUMINUM STOREFRONT SYSTEM - REFER TO SCHEDULES.
10 5100.E 15"W X 18" D PERSONAL STORAGE LOCKER
27 0000.B WALL MOUNTED TV, BY OWNER
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
FLOOR PLAN GENERAL NOTES
2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED.
3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER
INFORMATION.
4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF
PROVIDED.
5. NOT USED
6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY
NOTED OTHERWISE.
7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS,
SHELVING AND BATHROOM FIXTURES.
8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC
HEIGHT LIMITATIONS
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A
ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO
ROUGH DOOR OPENING
11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE
BARRIERS
12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE
MAINTAINED
13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY
OF PARTITION RATING
SCALE: 3/16" = 1'-0"A-101
FIRST FLOOR PLAN1
1
9/13/24
UP
UP
EXISTING STUD FRAMED WALL, TO REMAIN
WALL TYPES LEGEND
A1
A2
EXISTING WALL FURRING, TO REMAINA3
EXISTING MASONRY BLOCK WALL, TO REMAINA4
EXISTING CONCRETE WALL, TO REMAINA5
EXISTING STOREFRONT WALL, TO REMAINA6
NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP.
BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS
A7 EXISTING MASONRY BLOCK WALL, TO REMAIN
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
BREAK
ROOM
215
SERVER
216
WOMENS
222
MENS
129MEETING
ROOM
202
ELEVATOR
131
COPY
ROOM
210
ELEV MECH
112
DEPT.
CHIEF
211
CRIME
ANALYST
209
TRAIN/HIRING
MANAGER
208
EQUIP.
220
ADMIN
214A
DEPT.
CHIEF
213
INT
AFFAIRS
LIEUT.
224
BREAK
ROOM
207
BOS.
MANAGER
206
PUBLIC
AFFAIRS
MANAGER
205
HALL
149
JAN.
223
CONF.
202
STAIRS
152
STAIRS
144
JAN.
216
CHIEF
214C
A1
A1A2
A2
A-401
3
3
A-200
27 0000.B
27 0000.B
27 0000.B
11 5213.B
27 0000.B
214
A-411 4E4W
4N
4S
E222
224
5' - 6"
5' - 6"
A1
MA
T
C
H
E
X
.
C
O
L
U
M
N
W
I
D
T
H
MA
T
C
H
E
X
.
C
O
L
U
M
N
W
I
D
T
H
27 0000.B
13' - 2"
EQ.EQ.
EQ.EQ.
02 4013.AH
A1
A-413
3
4
A1
10 4400.E
10 4400.C
1
1
1
CLR
5' - 1 1/2"
A2
3' - 1"
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
PR
O
P
O
S
E
D
S
E
C
O
N
D
F
L
O
O
R
P
L
A
N
A-102
JH
JR
6/20/24
JR
KEYNOTES
02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE.
10 4400.C SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH
EXTINGUISHER, 2A:10B:C RATING ; REFER TO 7/A-903
10 4400.E PROVIDE NEW FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER AT EXISTING LOCATION
11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER,
COORDINATE POCKET INSTALLATION WITH CEILING
27 0000.B WALL MOUNTED TV, BY OWNER
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
FLOOR PLAN GENERAL NOTES
2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED.
3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER
INFORMATION.
4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF
PROVIDED.
5. NOT USED
6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY
NOTED OTHERWISE.
7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS,
SHELVING AND BATHROOM FIXTURES.
8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC
HEIGHT LIMITATIONS
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A
ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO
ROUGH DOOR OPENING
11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE
BARRIERS
12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE
MAINTAINED
13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY
OF PARTITION RATING
SCALE: 3/16" = 1'-0"A-102
SECOND FLOOR PLAN1
1
9/13/24
CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X"
LEGEND
LIGHT FIXTURE, REFER TO ELECTRICAL PLANS
MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS
INTERIOR - GYPSUM BOARD CEILING OVER
NEW 2X FRAMING
INTERIOR - ACOUSTIC CEILING TILE
REUSE OR MATCH EXISTING TILE AND GRID
CEILING ACCESS PANEL
DEMOLISHED OBJECTS
MATERIAL TAG
REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION
DEMO - INTERIOR - GYPSUM BOARD CEILING
SEE KEYNOTE
DEMO - INTERIOR - ACOUSTICAL CEILING TILE
SEE KEYNOTE
EXTERIOR - (E) SOFFIT TO REMAIN
ACT-1
ACT-1
GWB-1
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
09 2116.C
09 2116.C
09 5100.A
09 2116.H
10
A-902
09 2116.D
02 4013.BJ
02 4013.BJ
9' - 0"
8' - 5"
MEETING
125
OFFICE
124
BUREAU
SERGEANT
107
DRONE/EQUIP.
STORAGE
105
DETECTIVE
EQUIPMENT
106
ELECTRICAL
120
WOMEN
119
MEN
118
HALL
114
JAN.
117
HALL
115
STORAGE
111
STAIR
122
STAIR
123
BRIEFING
ROOM
122
HALL
139
LOBBY
100
ELEV.
127
SHARED
OFFICE
126
STORAGE
133
OPEN
OFFICE
102
INCIDENT
COM.
123
BREAK
ROOM
121
2' - 0"2' - 0"
09 2116.D
02 4013.BH
26 5000.A
26 5000.A
26 5000.A
26 0000.A
09 5100.H
8' - 0"
8' - 0"
23 0000.F
23 0000.F
VIF
09 2116.D
EQ EQ
EQ
E
Q
EQ
EQ
EQ EQ
11 5213.B
EQ EQ
09 5100.H
1
11' - 2 3/4"12' - 2"
09 5100.H
12
A-902
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
RE
F
L
E
C
T
E
D
C
E
I
L
I
N
G
P
L
A
N
-
F
I
R
S
T
F
L
O
O
R
A-111
JH
JR
6/20/24
JR
KEYNOTES
02 4013.BH EXISTING SOFFIT DROP TO REMAIN.
02 4013.BJ EXISTING BULKHEAD TO REMAIN.
09 2116.C GYPSUM BOARD CEILING ASSEMBLY
09 2116.D GYPSUM BOARD SOFFIT & FRAMING
09 2116.H NEW INTERIOR WALL TO DIE INTO BOTTOM OF SOFFIT. REPAIR
SOFFIT AROUND NEW WALL AS REQUIED.
09 5100.A ACOUSTICAL LAY-IN TILE CEILING
09 5100.H ACOUSTICAL CEILING TILE & GRID TO MATCH EXISTING OR REUSE
GOOD CONDITION SET ASIDE EXISTING TILE AND GRID
11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER,
COORDINATE POCKET INSTALLATION WITH CEILING
23 0000.F EXHAUST FAN - REFER TO MECHANICAL
26 0000.A NEW ILLUMINATED EXIT SIGN.
26 5000.A LIGHT FIXTURE. REFER TO ELECTRICAL
1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES.
5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH
FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED
CEILING PLAN, UNO.
6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH
FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED
INCLUDING POP RIVETS AND TAPPETS.
7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO
PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS
8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH
CEILING
9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL
SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING
FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN
BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE
VERTICAL STRUTS
RCP GENERAL NOTES
10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE
ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING
LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION.
11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING
ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA.
REFER TO SPECS FOR SHADE CLOTH
SCALE: 3/16" = 1'-0"A-111
REFLECTED CEILING PLAN - FIRST FLOOR
1
1
9/13/24
CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X"
LEGEND
LIGHT FIXTURE, REFER TO ELECTRICAL PLANS
MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS
INTERIOR - GYPSUM BOARD CEILING OVER
NEW 2X FRAMING
INTERIOR - ACOUSTIC CEILING TILE
REUSE OR MATCH EXISTING TILE AND GRID
CEILING ACCESS PANEL
DEMOLISHED OBJECTS
MATERIAL TAG
REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION
DEMO - INTERIOR - GYPSUM BOARD CEILING
SEE KEYNOTE
DEMO - INTERIOR - ACOUSTICAL CEILING TILE
SEE KEYNOTE
EXTERIOR - (E) SOFFIT TO REMAIN
ACT-1
ACT-1
GWB-1
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
ADMIN
214A
DEPT.
CHIEF
213
CHIEF
214C
STAIRS
144
INT
AFFAIRS
LIEUT.
224
BREAK
ROOM
207
BOS.
MANAGER
206
PUBLIC
AFFAIRS
MANAGER
205
BREAK
ROOM
215
SERVER
216
WOMENS
222
MENS
129
MEETING
ROOM
202
ELEVATOR
131
COPY
ROOM
210
ELEV MECH
112
DEPT.
CHIEF
211
CRIME
ANALYST
209
TRAIN/HIRING
MANAGER
208
EQUIP.
220
1275 SF
CONF.
202
HALL
149
09 5100.H
09 5100.H
09 5100.H
26 5000.F
09 5100.H
26 5000.A
09 5100.H
09 5100.H
23 0000.A
23 0000.F
26 5000.A
8' - 6"
8' - 6"
23 0000.F
23 0000.A
11 5213.B
EQ
E
Q
EQ EQ
EQ EQ
EQ
E
Q
6' - 0" EQ
EQ 7' - 0" EQ
4'
-
0
"
E
Q
09 5100.H
09 5100.H
1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
RE
F
L
E
C
T
E
D
C
E
I
L
I
N
G
P
L
A
N
-
S
E
C
O
N
D
F
L
O
O
R
A-112
JH
JR
6/20/24
JR
KEYNOTES
09 5100.H ACOUSTICAL CEILING TILE & GRID TO MATCH EXISTING OR REUSE
GOOD CONDITION SET ASIDE EXISTING TILE AND GRID
11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER,
COORDINATE POCKET INSTALLATION WITH CEILING
23 0000.A MECHANICAL EQUIPMENT. REFER TO MECHANICAL
23 0000.F EXHAUST FAN - REFER TO MECHANICAL
26 5000.A LIGHT FIXTURE. REFER TO ELECTRICAL
26 5000.F NEW LOCATION OF LIGHT FIXTURE. REFER TO ELECTRICAL.
1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES.
5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH
FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED
CEILING PLAN, UNO.
6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH
FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED
INCLUDING POP RIVETS AND TAPPETS.
7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO
PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS
8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH
CEILING
9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL
SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING
FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN
BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE
VERTICAL STRUTS
RCP GENERAL NOTES
10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE
ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING
LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION.
11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING
ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA.
REFER TO SPECS FOR SHADE CLOTH
SCALE: 3/16" = 1'-0"A-112
REFLECTED CEILING PLAN - SECOND FLOOR
1
9/13/24
LEGEND
(E) DECK. (E) SINGLE PLY ROOFING SYSTEM
1
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
02 4013.E
02 4013.E
02 4013.F
TYP.
02 4013.AE
TYP.
02 4013.AC
TYP.
02 4013.AC
23 0000.A
02 4013.AE
1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
RO
O
F
P
L
A
N
A-120
JH
JR
6/20/24
JR
KEYNOTES
02 4013.AC EXISTING LOW-SLOPE SINGLE-PLY ROOF TO REMAIN.
02 4013.AE EXISTING PARAPET CAP TO REMAIN.
02 4013.E EXISTING MECHANICAL UNIT TO REMAIN
02 4013.F EXISTING ROOF HATCH TO REMAIN
23 0000.A MECHANICAL EQUIPMENT. REFER TO MECHANICAL
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS
2. REFER TO MECHANICAL PLANS FOR ROOF MOUNTED EQUIPMENT
LOCATIONS AND TYPES.
3. REFER TO ELECTRICAL PLANS FOR POWER DISTRIBUTION TO ROOF
MOUNTED EQUIPMENT.
4. ALL ROOFING MATERIALS TO BE INSTALLED PER MANUFACTURER'S
SPECIFICATIONS.
ROOF PLAN GENERAL NOTES
SCALE: 3/16" = 1'-0"A-120
ROOF PLAN1
9/13/24
1 18316910
26 0000.L
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
1/8" = 1'-0"
EX
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
A-200
JH
JR
6/20/24
JR
26 0000.L EXISTING ILLUMINATED SIGNAGE CABINET TO REMAIN. NEW
ARTWORK PROVIDED BY OWNER UNDER SEPARATE PERMIT.
SCALE: 1/8" = 1'-0"A-101 A-200
WEST ELEVATION3
KEYNOTES
1
9/13/24
TYP.
10 2800.Q
10 2113.A
WOMENS
222
MENS
129
A-411 4E
A-411
3S
3N
3W 3E
4W
4N
4S
48" MIN. CLR.
48" MIN.CLR.
E222
60" MIN. CLR.
10 2113.A
30
"
X
4
8
"
CL
R
.
30
"
X
4
8
"
CL
R
.
10 2800.B
10 2800.B
10 2800.B
10 2800.B
30
"
X
4
8
"
C
L
R
.
10 2800.F
10 2800.F
10 2800.F
10 2800.C
10 2800.C
10 2800.C
JAN.
223
44" MIN CLR
22 0000.R
TYP.
22 0000.R
37"59"
1
1' - 6"
1
10 2800.G
22 0000.T
1' - 1"1' - 4"1' - 6 1/2"
6' - 9"
22 0000.Q
T-SHAPED TURNING
SPACE PER 11B-304.3.2,
KNEE CLEARANCE
PROVIDED AT
ACCESSIBLE LAV.
10 2113.C
10 2113.B
TYP.
10 2800.Q
10 2113.C
22 0000.Q02 4116.A
TYP.
10 2113.A
VIF
2' - 10"
1"
VIF
2' - 10"
VIF
5' - 4"
10 2800.G
VIF
2' - 8"
5' - 0" CLR
A-4111W
A-411
2N
1N
1E
1S
2W
2S
2E
MEN
118
WOMEN
119
TYP.
10 2800.Q
30"X48"
CLR.
30"X48"
CLR.
TYP.
10 2800.Q
10 2800.B
10 2800.B
59x60"
CLR.
59x60"
CLR.
10 2800.C
10 2800.F
10 2800.C
10 2800.F
DOOR SWING ALLOWED
TO ENCROACH ON
CLEAR FLOOR SPACE
PER 11B-603.2.3
1
22 0000.Q
10 2800.G
22 0000.R
CLR
48"
CLR
48"
22 0000.R22 0000.Q
10 2800.G
1
MEN
118
WOMEN
119
02 4116.A
02 4116.U
02 4116.CM
02 4116.CM
02 4116.A
02 4116.B
02 4116.CC
02 4116.U
02 4116.A02 4116.A
02 4116.CC
02 4116.A
02 4116.A
02 4116.B
02 4116.A
02 4116.B
02 4116.B
02 4116.U
TYP.
02 4116.CM
02 4116.U
02 4116.A
02 4116.A
02 4116.A
TYP.
02 4116.CM
TYP.
02 4116.CC
TYP.
02 4116.CC
02 4116.H
02 4116.E
02 4116.CB
02 4116.A
TYP.
02 4116.B
DEMO EXISTING PARTITION OR
WALL FINISH
DEMO - INTERIOR - TILE
NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS
A-501 & A-502 FOR ADDTIONAL INFORMATION.
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
EN
L
A
R
G
E
D
F
L
O
O
R
P
L
A
N
S
A-401
JH
JR
6/20/24
JR
KEYNOTES
02 4116.A EXISTING PLUMBING FIXTURE TO BE REMOVED
02 4116.B EXISTING TOILET PARTITION TO BE REMOVED
02 4116.CB EXISTING INTERIOR WALL TO BE REMOVED. PROTECT IN PLACE
EXISTING ADJACENT WALL. PATCH WALL GAP AFTER DEMOLITION
OF EXISITNG WALL.
02 4116.CC EXISTING WALL TILE TO BE REMOVED. PREPARE WALL SURFACE
FOR NEW TILE FINISH TYP. OF ALL RESTROOM WALLS.
02 4116.CM EXISTING GRAB BAR TO BE REMOVED
02 4116.E EXISTING DOOR AND FRAME TO BE REMOVED
02 4116.H EXISTING DOOR TO BE REMOVED. FLIP DOOR SWING DIRECTION
AND REINSTALL.
02 4116.U EXISTING TILE FLOOR TO BE REMOVED. PREPARE (E) SLAB FOR
NEW TILE FINISHES
10 2113.A TOILET COMPARTMENT
10 2113.B URINAL SCREEN
10 2113.C SELF CLOSING DOOR AT ACCESSIBLE TOILET STALL
10 2800.B SURFACE MOUNTED TOILET PAPER DISPENSER
10 2800.C SOAP DISPENSER
10 2800.F MIRROR
10 2800.G SEMI-RECESSED PAPER TOWEL DISPENSER
10 2800.Q GRAB BAR.
22 0000.Q SINK OR LAVATORY.REFER TO PLUMBING.
22 0000.R TOILET. REFER TO PLUMBING.
22 0000.T URINAL. REFER TO PLUMBING.
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
FLOOR PLAN GENERAL NOTES
2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED.
3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER
INFORMATION.
4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF
PROVIDED.
5. NOT USED
6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY
NOTED OTHERWISE.
7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS,
SHELVING AND BATHROOM FIXTURES.
8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC
HEIGHT LIMITATIONS
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A
ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO
ROUGH DOOR OPENING
11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE
BARRIERS
12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE
MAINTAINED
13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY
OF PARTITION RATING
SCALE: 3/8" = 1'-0"A-102 A-401
2ND FLOOR RESTROOM - PROPOSED
3
FLOOR MATERIALS LEGEND
SCALE: 3/8" = 1'-0"A-101 A-401
FIRST FLOOR RESTROOM - PROPOSED
4
SCALE: 3/8" = 1'-0"AD-101 A-401
FIRST FLOOR RESTROOM - DEMO
1
SCALE: 3/8" = 1'-0"AD-102 A-401
SECOND FLOOR RESTROOM - DEMO
2
1
9/13/24
09 3000.A
1' - 0"
3' - 6"
0' - 6"
1' - 0"
3' - 6"
3' - 6"
1' - 0"
1' - 0"
3' - 6"
1' - 0"
3' - 6"
1' - 0"
3' - 6"
1
1' - 0"
3' - 6"
3' - 6"
1' - 0"
1' - 0"
3' - 6"
1' - 0"
3' - 6"
0' - 6"
1' - 0"
3' - 6"
3' - 6"
1' - 0"
1' - 0"
3' - 6"
0' - 6"
LVT-1 MATERIAL TAG
REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION
NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS
A-501 & A-502 FOR ADDTIONAL INFORMATION.
###DW
H
ARCHITECTURAL WOODWORK
STANDARD CABINET DESIGN
SERIES NUMBER
OPT. DESIGN MOD
DESCRIPTION
D = DEPTH
W = WIDTH
H = HEIGHT
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
1/4" = 1'-0"
I
N
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
A-411
JH
JR
6/20/24
JR
1/4" = 1'-0"118 - MENS RESTROOM - FIRST FLOOR
1N 1E 1S 1W 2E
1/4" = 1'-0"119 - WOMENS RESTROOM - FIRST FLOOR
2N 2S 2W
1/4" = 1'-0"129 - MENS RESTROOM - SECOND FLOOR
3N 3E 3S 3W
1/4" = 1'-0"222 - WOMENS RESTROOM - SECOND FLOOR
4N 4E 4S 4W
09 3000.A CERAMIC TILE, WALL APPLICATION.
KEYNOTES
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION ON ELECTRICAL
EQUIPMENT.
3. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION.
4. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND
FIXTURES OCCUR.
5. ALL DIMENSIONS SHOWN IN A ROOM TO BE CONSIDERED TYPICAL FOR EACH
ELEVATION OF THE ROOM, UNLESS NOTED OTHERWISE.
6. VERIFY MOUNTING HEIGHTS OF ACCESSORIES AND PLUMBING FIXTURES
MEET ACCESSIBILITY REQUIREMENTS WHERE APPLICABLE.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE
803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
INT. ELEVS. GENERAL NOTES LEGEND1
9/13/24
10
A-902
S-4
126
10' - 0"
TYP.
06 1000.Q
27 0000.B
27 0000.A
LVT-1 MATERIAL TAG
REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION
NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS
A-501 & A-502 FOR ADDTIONAL INFORMATION.
###DW
H
ARCHITECTURAL WOODWORK
STANDARD CABINET DESIGN
SERIES NUMBER
OPT. DESIGN MOD
DESCRIPTION
D = DEPTH
W = WIDTH
H = HEIGHT
06 1000.Q
S-1 S-1 S-1 S-1 S-1
7' - 0"
S-2 S-2
122A 122B
27 0000.B
27 0000.A 27 0000.A
02 4013.A
27 0000.B
02 4013.BK
08 8000.D
08 4313.A 11 5213.B 02 4013.A
08 8000.D
122B
S-2
122A
S-2
S-1S-1 S-1 S-1 S-1
114
08 4313.A
08 8000.D
02 4013.A
22 0000.O
A-902
12 OPP
5' - 0"
T-1 W/ TB-1 COVE BASE, INSIDE
CORNER TO INSIDE CORNER AT
DRINKING FOUNTAIN ALCOVE
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
1/4" = 1'-0"
I
N
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
A-412
JH
JR
6/20/24
JR1/4" = 1'-0"102 - OPEN OFFICE - PROPOSED
4
1. REFER TO GENERAL NOTES SHEET G-002 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION ON ELECTRICAL
EQUIPMENT.
3. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION.
4. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND
FIXTURES OCCUR.
5. ALL DIMENSIONS SHOWN IN A ROOM TO BE CONSIDERED TYPICAL FOR EACH
ELEVATION OF THE ROOM, UNLESS NOTED OTHERWISE.
6. VERIFY MOUNTING HEIGHTS OF ACCESSORIES AND PLUMBING FIXTURES
MEET ACCESSIBILITY REQUIREMENTS WHERE APPLICABLE.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE
803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
8. REFER TO FINISH SCHEDULE ON A-501 FOR WALL FINISH MATERIALS AND
COLOR SELECTIONS.
9. TILE SHOULD STOP AT TOP OF DOOR JAMB.
INT. ELEVS. GENERAL NOTES
02 4013.A EXISTING STOREFRONT TO REMAIN. PROTECT IN PLACE
02 4013.BK EXISTING PRIVACY FILM TO REMAIN.
06 1000.Q PROVIDE BLOCKING FOR FUTURE OWNER PROVIDED
WALL-MOUNTED TV BRACKET
08 4313.A ALUMINUM STOREFRONT SYSTEM - REFER TO SCHEDULES.
08 8000.D FROSTED GLASS PRIVACY SCREEN
11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER,
COORDINATE POCKET INSTALLATION WITH CEILING
22 0000.O HI LOW DRINKING FOUNTAIN, REFER TO PLUMBING.
27 0000.A CABLE/DATA/POWER CONNECTION, RE ELEC
27 0000.B WALL MOUNTED TV, BY OWNER
KEYNOTES
1/4" = 1'-0"102 - MEETING AREA
3
LEGEND
1/4" = 1'-0"122 - BRIEFING ROOM
1 2
5
1
1
9/13/24
V.I.F.
2' - 10"
MODIFY CABINET TO PROVIDE
ACCESSIBLE KITCHEN SINK, SEE DETAIL
9
A-903
V.
I
.
F
.
2'
-
1
0
"
2' - 6"
2' - 0"
2' - 10"
24
33
24211
24
30
13301 48
30
13302 24
30
13301
48
33
24155
12 3600.D
42
33
42197
06 4100.O
06 4100.J
9
A-903
2' - 10"
2' - 0"
2' - 6"
48
33
24222
48
30
1330224
30
13301
42
33
42197
06 4100.O
06 4100.J
12 3600.D
11 3100.D
LVT-1 MATERIAL TAG
REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION
NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS
A-501 & A-502 FOR ADDTIONAL INFORMATION.
###DW
H
ARCHITECTURAL WOODWORK
STANDARD CABINET DESIGN
SERIES NUMBER
OPT. DESIGN MOD
DESCRIPTION
D = DEPTH
W = WIDTH
H = HEIGHT
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
I
N
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
A-413
JH
JR
6/20/24
JR
2
3/8" = 1'-0"BREAK RM 121
1
3/8" = 1'-0"BREAK RM 215
3 4
1. REFER TO GENERAL NOTES SHEET G-002 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION ON ELECTRICAL
EQUIPMENT.
3. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION.
4. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND
FIXTURES OCCUR.
5. ALL DIMENSIONS SHOWN IN A ROOM TO BE CONSIDERED TYPICAL FOR EACH
ELEVATION OF THE ROOM, UNLESS NOTED OTHERWISE.
6. VERIFY MOUNTING HEIGHTS OF ACCESSORIES AND PLUMBING FIXTURES
MEET ACCESSIBILITY REQUIREMENTS WHERE APPLICABLE.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE
803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
8. REFER TO FINISH SCHEDULE ON A-501 FOR WALL FINISH MATERIALS AND
COLOR SELECTIONS.
9. TILE SHOULD STOP AT TOP OF DOOR JAMB.
INT. ELEVS. GENERAL NOTES KEYNOTES LEGEND
06 4100.J BASE CABINETS W/ DRAWERS, DOORS & ADJUSTABLE SHELVING
06 4100.O UPPER CABINET W/ DOORS & ADJUSTABLE SHELVING.
11 3100.D REFRIGERATOR W/ ICE MAKER; OWNER FURNISHED AND
INSTALLED. COORDINATE INSTALLATION WITH OWNER.
12 3600.D PLASTIC LAMINATE COUNTERTOP & BACKSPLASH
1
9/13/24
UP
PF
EXISTING FLOORING TO REMAIN
FINISH LEGEND
NEW PORCELAIN TILE FLOOR
NEW LVT FLOOR
NEW CARPET TILE FLOOR
NEW WALK OFF MAT CARPET TILE
STAINLESS STEEL
CORNER GUARD
FLOORING INSTALL
DIRECTION
SHARED
OFFICE
BUREAU
SERGEANT
STORAGE
STAIR
251 SF
LOBBY
ELEV.
OFFICE
MEETING
BRIEFING
ROOM
HALL
HALL
121 SF
STAIR
MEN
WOMEN
99 SF
ELECTRICAL
HALL
JAN.
DRONE/EQUIP.
STORAGE
DETECTIVE
EQUIPMENT
INCIDENT
COM.BREAK
ROOM
STORAGE
CPT-1
CPT-1
CPT-1
CPT-1
CPT-1
CPT-1
CPT-1
LVT-1 LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
WOM-1
WOM-1
RBR-1
RBR-1
CPT-1
P-3
T-1
T-1
T-2
T-2
P-2
P-2
P-
2
TB-1
P-3
P-3 P-3
TB-1
OPEN
OFFICE
P-2
P-2
B-1
B-1
(E)
(E)
(E)
A G H
B B
A
B
A
B
B
B
B
B
RS-1 RS-1 RS-1 RS-1
RS-1
RS-1
RS-1
RS-1
E
D
E
D
1
B
B
B
B
B
A A
B
B
A
A
K
K
G
T-1
TACTILE EXIT SIGN READING "EXIT". WHERE MOUNTED ON
GLASS, SIZE EXIT SIGN TO MATCH EXTERIOR GLASS
MOUNTED ROOM IDENTIFICAITON SIGNAGE. ALIGN EXIT
SIGN WITH ROOM SINGAGE WHEN MOUNTING.:
ROOM IDENTIFICATION SIGN. WHERE MOUNTED ON GLASS
PROVIDE SIZE MATCHED BLANK SIGNAGE PLATE ON BACK SIDE OF
GLASS IF NO OTHER SINGAGE IS PROVIDED. CONTENT TBD BY
OWNER:
A
B
OCCUPANT LOAD SIGN THAT STATES "MAXIMUM OCCUPANCY 54
PERSONS"
H
GEOMETRIC SYMBOL MOUNTED ON DOOR.D
E ROOM IDENTIFICATION WITH PICTOGRAM AND
INTERNATIONAL SYMBOL OF ACCESSIBILITY.
INTERNATIONAL SYMBOL OF ACCESS FOR HEARING IMPAIRED,
INCLUDE WORDING THAT STATES, "ASSISTIVE LISTENING
SYSTEM AVAILABLE."
G
SIGN TO READ "EXTERIOR AREA FOR ASSISTED RESCUE". SIGNAGE TO
COMPLY WITH CBC 1009.9.
J
SIGN TO READ "PLEASE BE AWARE, VIDEO MONITORING IN PROGRESS"K
1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
1/8" = 1'-0"
FI
R
S
T
F
L
O
O
R
F
I
N
I
S
H
P
L
A
N
A-501
JH
JR
6/20/24
JR
INTERIOR FINISH SCHEDULE
SCALE: 1/8" = 1'-0"A-501
01-FIRST FLOOR FINISH PLAN1
A-1 & A-2
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
(CBC 2022 TABLE 803.13)
CLASSIFICATIONS
CLASS A:
• FLAME SPREAD INDEX = 0-25
• SMOKE DEVELOPED INDEX = 0-450
CLASS B:
• FLAME SPREAD INDEX = 26-75
• SMOKE DEVELOPED INDEX = 0-450
CLASS C:
• FLAME SPREAD INDEX = 76-200
• SMOKE DEVELOPED INDEX = 0-450
A-3,A-4,A-5
B,E,M,R-1
R-2
R-2.1
R-2.2
R-3, R-3.1
S
GROUP INTERIOR EXIT
STAIRWAYS AND
RAMPS AND EXIT
PASSAGEWAYS
CORRIDORS AND
ENCLOSURE FOR EXIT
ACCESS STAIRWAYS
AND RAMPS
ROOMS AND
ENCLOSED SPACES
B
B
B
C
B
C
C
C
B
B
C
C
C
C
C
C
C
C
C
C
C
C
C
C
PER 2022 CBC 803.13 INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME
SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE 803.13 FOR THE
GROUP AND LOCATION DESIGNATED. REFER TO 2022 CBC SEC. 803 FOR
ADDITIONAL INFORMATION.
DEGREE OF FIRE PROTECTION: SPRINKLERED
FINISH REQUIREMENTS
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES AND INTERIOR FINISH
DETAILS.
5. ALL HARD SURFACE FLOORING SHALL BE SLIP RESISTANT AND MEET THE
ANSI A326.3 STANDARD FOR MEASURING THE DYNAMIC COEFFICIENT OF
FRICTION (DCOF).
6. ALL FLOORING MATERIALS SHALL COMPLY WITH 2022 CBC SEC. 804.1.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE
803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
8. PROVIDE ROLLER SHADES AT ALL EXTERIOR WINDOWS AND STOREFRONT
EXCEPT AT DOORS. SEE SPECS
FINISH PLAN GENERAL NOTES
CSI Spec Section TAG DESCRIPTION LOCATION MANUFACTURER PRODUCT SPEC SIZE FINISH / COLOR NOTES
(E) EXISTING FINISH TO REMAIN SEE PLANS
06 4000- ARCHITECTURAL WOODWORK
06 4000- ARCHITECTURAL
WOODWORK
PL-2 PLASTIC LAMINATE - CABINETS BREAK ROOM NEVAMAR NAVY MATRIX (MR3005T)
09 3000 - TILING
09 3000 - TILING T-1 CERAMIC FLOOR & WALL TILE RESTROOMS DALTILE DIGNITARY 12" X 24" SUPERIOR TAUPE
09 3000 - TILING T-2 ACCENT CERAMIC WALL TILE RESTROOMS DALTILE REVALIA REMIX RADIANT BLUE FAN 12" ACCENT STRIP STARTING AT 48"
09 3000 - TILING TB-1 CERAMIC TILE COVE BASE RESTROOMS DALTILE DIGNITARY 6" X 12" SUPERIOR TAUPE
09 6500 - RESILIENT FLOORING
09 6500 - RESILIENT
FLOORING
B-1 GENERAL BASE GENERAL U.O.N. ROPPE PINNACLE 4" H (ROLL) BLACK (100)
09 6500 - RESILIENT
FLOORING
LVT-1 LUXURY VINYL TILE BREAK ROOM, EQUIP., STORAGE MILLIKEN METRO PARK | PIKE 7" x 48" ANTLER ASHLAR INSTALLATION
09 6500 - RESILIENT
FLOORING
RBR-1 RUBBER STAIR TREADS STAIRS ROPPE RAISED CIRCULAR VANTAGE DESIGN
WITH RISER #96
CHARCOAL (123)
09 6813 - TILE CARPETING
09 6813 - TILE CARPETING CPT-1 CARPET TILE GENERAL CARPET TILE U.O.N. SHAW CONTRACT DIFFUSE + DISPERSE | DIFFUSE
ECOWORX
24" x 24" MAGNETIC FIELD QUARTER TURN INSTALLATION
09 6813 - TILE CARPETING WOM-1 CARPET TILE EXITS SHAW CONTRACT ALL ACCESS | PACE TILE 24" x 24" STEP MONOLITHIC INSTALLATION
09 9123 - INTERIOR PAINTING
09 9123 - INTERIOR
PAINTING
P-1 GENERAL DINING PAINT GENERAL U.O.N. SHERMIN WILLIAMS PASSIVE (SW 7064) EGGSHELL FINISH
09 9123 - INTERIOR
PAINTING
P-2 ACCENT PAINT PRIVATE OFFICES, PAINTED DOORS AND
HM DOOR TRIM
SHERMIN WILLIAMS STAMPED CONCRETE (SW 7655) EGGSHELL FINISH
09 9123 - INTERIOR
PAINTING
P-3 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS DISTANCE (SW 6243) EGGSHELL FINISH
09 9123 - INTERIOR
PAINTING
P-4 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS IN THE NAVY (SW 9178) EGGSHELL FINISH
10 2113.19 - PLASTIC TOILET COMPARTMENTS
10 2113.19 - PLASTIC
TOILET COMPARTMENTS
TP-1 CARPET TILE SECOND LEVEL RESTROOMS ASI SOLID PLASTIC (HDPE) PARTITIONS CHARCOAL (9237) FLOOR ANCHORED / OVERHEAD BRACED
12 2400 - WINDOW SHADES
12 2400 - WINDOW SHADES RS-1 ROLLER SHADE SEE PLANS MECHO SHADES MANUAL ROLLER SHADES WITH
ECOVEIL SCREENS (1% OPEN)
SILVER BIRCH ADD ALT TO REPLACE ALL WINDOW SHADES PER PLAN
12 3600 - COUNTERTOPS
12 3600 - COUNTERTOPS PL-1 PLASTIC LAMINATE - COUNTER BREAK ROOM FORMICA SEA SEALT (9529-43)
SIGNAGE LEGEND
9/13/24
UP
UP
PF
EXISTING FLOORING TO REMAIN
FINISH LEGEND
NEW PORCELAIN TILE FLOOR
NEW LVT FLOOR
NEW CARPET TILE FLOOR
NEW WALK OFF MAT CARPET TILE
STAINLESS STEEL
CORNER GUARD
FLOORING INSTALL
DIRECTION
BREAK
ROOM
SERVER
WOMENS
MENSMEETING
ROOM
ELEVATOR
131
COPY
ROOM
ELEV MECH
DEPT.
CHIEF
CRIME
ANALYST
TRAIN/HIRING
MANAGER
EQUIP.
ADMIN
DEPT.
CHIEF
INT
AFFAIRS
LIEUT.
BREAK
ROOM
BOS.
MANAGER
PUBLIC
AFFAIRS
MANAGER
HALL
149
JAN.
CONF.
STAIRS
152
STAIRS
144
JAN.
216
CHIEF
RBR-1
RBR-1
CPT-1
CPT-1
CPT-1
T-1
T-2
P-3
TB-1
T-1
T-1
T-2
TB-1
T-1
CPT-1
CPT-1
CPT-1
CPT-1 CPT-1
CPT-1CPT-1
LVT-1
LVT-1
LVT-1
P-
2
P-
2
P-
2
P-
2
P-
3
P-3
CPT-1
HALL
132
(E)
CPT-1
CPT-1
(E)
(E)
(E)
CPT-1
P-
2
P-
2
P-3
P-
2
P-2
P-2
P-4
P-4
P-
3
G
B B
B
B
B
B
B
B
B A
B
TP-1
TP-1
RS-1 RS-1 RS-1
RS-1RS-1RS-1RS-1
RS
-
1
PL-1
PL-2
D
E
D E
B
B
B
B
B
B
G
TACTILE EXIT SIGN READING "EXIT". WHERE MOUNTED ON
GLASS, SIZE EXIT SIGN TO MATCH EXTERIOR GLASS
MOUNTED ROOM IDENTIFICAITON SIGNAGE. ALIGN EXIT
SIGN WITH ROOM SINGAGE WHEN MOUNTING.:
ROOM IDENTIFICATION SIGN. WHERE MOUNTED ON GLASS
PROVIDE SIZE MATCHED BLANK SIGNAGE PLATE ON BACK SIDE OF
GLASS IF NO OTHER SINGAGE IS PROVIDED. CONTENT TBD BY
OWNER:
A
B
OCCUPANT LOAD SIGN THAT STATES "MAXIMUM OCCUPANCY 54
PERSONS"
H
GEOMETRIC SYMBOL MOUNTED ON DOOR.D
E ROOM IDENTIFICATION WITH PICTOGRAM AND
INTERNATIONAL SYMBOL OF ACCESSIBILITY.
INTERNATIONAL SYMBOL OF ACCESS FOR HEARING IMPAIRED,
INCLUDE WORDING THAT STATES, "ASSISTIVE LISTENING
SYSTEM AVAILABLE."
G
SIGN TO READ "EXTERIOR AREA FOR ASSISTED RESCUE". SIGNAGE TO
COMPLY WITH CBC 1009.9.
J
SIGN TO READ "PLEASE BE AWARE, VIDEO MONITORING IN PROGRESS"K
1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
1/8" = 1'-0"
SE
C
O
N
D
F
L
O
O
R
F
I
N
I
S
H
P
L
A
N
A-502
JH
JR
6/20/24
JR
ROOM FINISH SCHEDULE
A-1 & A-2
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
(CBC 2022 TABLE 803.13)
CLASSIFICATIONS
CLASS A:
• FLAME SPREAD INDEX = 0-25
• SMOKE DEVELOPED INDEX = 0-450
CLASS B:
• FLAME SPREAD INDEX = 26-75
• SMOKE DEVELOPED INDEX = 0-450
CLASS C:
• FLAME SPREAD INDEX = 76-200
• SMOKE DEVELOPED INDEX = 0-450
A-3,A-4,A-5
B,E,M,R-1
R-2
R-2.1
R-2.2
R-3, R-3.1
S
GROUP INTERIOR EXIT
STAIRWAYS AND
RAMPS AND EXIT
PASSAGEWAYS
CORRIDORS AND
ENCLOSURE FOR EXIT
ACCESS STAIRWAYS
AND RAMPS
ROOMS AND
ENCLOSED SPACES
B
B
B
C
B
C
C
C
B
B
C
C
C
C
C
C
C
C
C
C
C
C
C
C
PER 2022 CBC 803.13 INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME
SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE 803.13 FOR THE
GROUP AND LOCATION DESIGNATED. REFER TO 2022 CBC SEC. 803 FOR
ADDITIONAL INFORMATION.
DEGREE OF FIRE PROTECTION: SPRINKLERED
FINISH REQUIREMENTS
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES AND INTERIOR FINISH
DETAILS.
5. ALL HARD SURFACE FLOORING SHALL BE SLIP RESISTANT AND MEET THE
ANSI A326.3 STANDARD FOR MEASURING THE DYNAMIC COEFFICIENT OF
FRICTION (DCOF).
6. ALL FLOORING MATERIALS SHALL COMPLY WITH 2022 CBC SEC. 804.1.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE
803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
8. PROVIDE ROLLER SHADES AT ALL EXTERIOR WINDOWS AND STOREFRONT
EXCEPT AT DOORS. SEE SPECS
FINISH PLAN GENERAL NOTES
SCALE: 1/8" = 1'-0"A-502
SECOND FLOOR FINISH PLAN1
CSI Spec Section TAG DESCRIPTION LOCATION MANUFACTURER PRODUCT SPEC SIZE FINISH / COLOR NOTES
(E) EXISTING FINISH TO REMAIN SEE PLANS
06 4000- ARCHITECTURAL WOODWORK
06 4000- ARCHITECTURAL
WOODWORK
PL-2 PLASTIC LAMINATE - CABINETS BREAK ROOM NEVAMAR NAVY MATRIX (MR3005T)
09 3000 - TILING
09 3000 - TILING T-1 CERAMIC FLOOR & WALL TILE RESTROOMS DALTILE DIGNITARY 12" X 24" SUPERIOR TAUPE
09 3000 - TILING T-2 ACCENT CERAMIC WALL TILE RESTROOMS DALTILE REVALIA REMIX RADIANT BLUE FAN 12" ACCENT STRIP STARTING AT 48"
09 3000 - TILING TB-1 CERAMIC TILE COVE BASE RESTROOMS DALTILE DIGNITARY 6" X 12" SUPERIOR TAUPE
09 6500 - RESILIENT FLOORING
09 6500 - RESILIENT
FLOORING
B-1 GENERAL BASE GENERAL U.O.N. ROPPE PINNACLE 4" H (ROLL) BLACK (100)
09 6500 - RESILIENT
FLOORING
LVT-1 LUXURY VINYL TILE BREAK ROOM, EQUIP., STORAGE MILLIKEN METRO PARK | PIKE 7" x 48" ANTLER ASHLAR INSTALLATION
09 6500 - RESILIENT
FLOORING
RBR-1 RUBBER STAIR TREADS STAIRS ROPPE RAISED CIRCULAR VANTAGE DESIGN
WITH RISER #96
CHARCOAL (123)
09 6813 - TILE CARPETING
09 6813 - TILE CARPETING CPT-1 CARPET TILE GENERAL CARPET TILE U.O.N. SHAW CONTRACT DIFFUSE + DISPERSE | DIFFUSE
ECOWORX
24" x 24" MAGNETIC FIELD QUARTER TURN INSTALLATION
09 6813 - TILE CARPETING WOM-1 CARPET TILE EXITS SHAW CONTRACT ALL ACCESS | PACE TILE 24" x 24" STEP MONOLITHIC INSTALLATION
09 9123 - INTERIOR PAINTING
09 9123 - INTERIOR
PAINTING
P-1 GENERAL DINING PAINT GENERAL U.O.N. SHERMIN WILLIAMS PASSIVE (SW 7064) EGGSHELL FINISH
09 9123 - INTERIOR
PAINTING
P-2 ACCENT PAINT PRIVATE OFFICES, PAINTED DOORS AND
HM DOOR TRIM
SHERMIN WILLIAMS STAMPED CONCRETE (SW 7655) EGGSHELL FINISH
09 9123 - INTERIOR
PAINTING
P-3 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS DISTANCE (SW 6243) EGGSHELL FINISH
09 9123 - INTERIOR
PAINTING
P-4 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS IN THE NAVY (SW 9178) EGGSHELL FINISH
10 2113.19 - PLASTIC TOILET COMPARTMENTS
10 2113.19 - PLASTIC
TOILET COMPARTMENTS
TP-1 CARPET TILE SECOND LEVEL RESTROOMS ASI SOLID PLASTIC (HDPE) PARTITIONS CHARCOAL (9237) FLOOR ANCHORED / OVERHEAD BRACED
12 2400 - WINDOW SHADES
12 2400 - WINDOW SHADES RS-1 ROLLER SHADE SEE PLANS MECHO SHADES MANUAL ROLLER SHADES WITH
ECOVEIL SCREENS (1% OPEN)
SILVER BIRCH ADD ALT TO REPLACE ALL WINDOW SHADES PER PLAN
12 3600 - COUNTERTOPS
12 3600 - COUNTERTOPS PL-1 PLASTIC LAMINATE - COUNTER BREAK ROOM FORMICA SEA SEALT (9529-43)
SIGNAGE LEGEND
1
9/13/24
PF
BUREAU
SERGEANT
107
MEETING
125
OFFICE
124
DRONE/EQUIP.
STORAGE
105
DETECTIVE
EQUIPMENT
106
ELECTRICAL
120
WOMEN
119
MEN
118
HALL
114
JAN.
117
HALL
115
STORAGE
111
STAIR
122
STAIR
123
BRIEFING
ROOM
122
HALL
139
LOBBY
100
ELEV.
127
SHARED
OFFICE
126
3' - 10 7/16"
7'
-
0
"
4'
-
0
"
2' - 9"
2' - 6"
SEE SUPPORTING
DOCUMENTS FOR
FURNITURE SCHEDULE
2' - 8 3/4"
BREAK
ROOM
121
INCIDENT
COM.
123
SE-04
CG-06
SE-05
CG-05
CG-03
SE-06
CG-08
SE-01
CG-08
SE-01
CG-09
SE-01
ST-01
ST-05
CG-13
SE-01
ST-01
ST-02
ST-02
CG-11
SE-01
ST-01
SE-02
SE-02
ST-07ST-07
7' - 9"
CG-20
7' - 5 57/128"
SE-03
SE-03
CG-23
CG-10
CG-27
E-5
E-4
E-3
E-2
E-1
ST-01
TYP.
TYP.
ST-01 ST-01
OPEN
OFFICE
102
ST-04
CG-14
TYP.
TYP.
ST-01
TYP.
CG-09
ST-01
1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
3/16" = 1'-0"
FI
R
S
T
F
L
O
O
R
F
U
R
N
I
T
U
R
E
P
L
A
N
A-503
JH
JR
6/20/24
JR
SCALE: 3/16" = 1'-0"A-503
FIRST FLOOR FURNITURE PLAN1
9/13/24
UP
UP
BREAK
ROOM
215
SERVER
216
WOMENS
222
MENS
129
MEETING
ROOM
202
ELEVATOR
131
COPY
ROOM
210
ELEV MECH
112
DEPT.
CHIEF
211
CRIME
ANALYST
209
TRAIN/HIRING
MANAGER
208
EQUIP.
220
ADMIN
214A
DEPT.
CHIEF
213
INT
AFFAIRS
LIEUT.
224
BREAK
ROOM
207BOS.
MANAGER
206
PUBLIC
AFFAIRS
MANAGER
205
HALL
149
JAN.
223
CONF.
202
STAIRS
152
STAIRS
144
JAN.
216
CHIEF
214C
REF.
ST
O
R
A
G
E
ST-03
CG-15
SE-01
ST-08
SE-03
SE-08
CG-17
CG-18
SE-03
CG-16
ST-07
ST-01
CG-13
SE-01
SE-03
ST-06
CG-07
SE-04
SE-09
ST-04
SE-05
CG-05 ST-02
ST-01
CG-12
SE-01
SE-03
ST-02
ST-01
CG-12
SE-01
SE-03
SE-03
CG-04
SE-01
CG-13
ST-01
SE-01
ST-01
CG-13
ST-02
ST-01
CG-11
SE-01
SE-03
7' - 6 1/2"2' - 10 7/16"7' - 4 1/2"2' - 0"10' - 10"
5' - 5"
5'
-
1
1
"
6'
-
2
"
0"
2
'
-
0
"
8
'
-
5
"
CG-29
12' - 2"
3' - 10"
CG-03
SE-06ST-05
SE-01
ST-01
CG-13
ST-02
CG-21
CG-30
ST-06
CG-30
CG-22
CG-25
CG-26
SE-03
SE-03
SE-03
CG-19CG-14
CG-28
ST-02
ST-02
E-6
CG-14
ST-04
ST-02
ST-01
CG-12
SE-01
SE-03
CG-24
SEE SUPPORTING
DOCUMENTS FOR
FURNITURE SCHEDULE
1
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
3/16" = 1'-0"
SE
C
O
N
D
F
L
O
O
R
F
U
R
N
I
T
U
R
E
P
L
A
N
A-504
JH
JR
6/20/24
JR
SCALE: 3/16" = 1'-0"A-504
SECOND FLOOR FURNITURE PLAN1
9/13/24
0' - 2"W 0' - 2"
0' - 2"
H
H
W
TYPE 1A
F1
DOOR TYPES
FRAME TYPES
FF
H
W
TYPE 1D
FULL LITE
OBSCURED
W/ WINDOW
PRIVACY
FILMH
W
TYPE 1B
6" 8"
3'
-
7
"
2
'
-
9
"
8
"
8"
1'
-
0
"
1
V.I.F.
4' - 0"
V.I.F.
7' - 2 3/4"
V.I.F.
3' - 3"
0' - 2"0' - 2"
0' - 2"
0' - 2"
2' - 2 3/4"
4' - 8"
ALUMINUM STOREFRONT
2" X 4-1/2"
FIXED
S-1
5
A-901
4
A-901
6
A-901
V.I.F.
11' - 2 3/4"
FLOAT GLASS, TEMPERED
OBSCURED GLASS, TEMPERED
INSTALL WINDOW PRIVACY FILM
GLAZING LEGEND TYPICAL DETAILS
TYPICAL JAMB AT ADJACENT STOREFRONT
ALUMINUM STOREFRONT
2" X 4-1/2"
DOOR WITH TRANSOM
S-2
V.I.F.
3' - 4"
0' - 2"0' - 2"
V.I.F.
11' - 2 3/4"
7' - 0"
0' - 2"
3' - 10 3/4"
0' - 2"
FULL LITE
OBSCURED W/
WINDOW
PRIVACY FILM
5
A-901
1
A-901
1. CL
2. HM
3. MP
4. STL
5. WD
6. T
CHAIN LINK
HOLLOW METAL
METAL PICKET
STEEL
WOOD
SAFETY GLAZING
FULL LITE
OBSCURED W/
WINDOW
PRIVACY FILM
ALUMINUM STOREFRONT
2" X 4-1/2"
S-3
0' - 2"4' - 8"0' - 2"6' - 0"0' - 2"4' - 8"0' - 2"
16' - 0"
11' - 2 3/4"
0' - 2"
2' - 10 3/4"
0' - 2"
5' - 6"
0' - 2"
2' - 4"
8' - 0"
3
A-901
1
A-901
6
A-901
1
3' - 0"
0' - 2"
2' - 10"
100A
ALUMINUM STOREFRONT
2" X 4-1/2"
6
A-901
1
A-901
3
A-901
S-4
126
7' - 2"
0' - 2"
6' - 10"
0' - 2"
8' - 5"
2"2' - 4 1/2"
2"
2' - 4 1/2"
2"
3' - 0"2"
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DO
O
R
A
N
D
W
I
N
D
O
W
S
C
H
E
D
U
L
E
S
A-601
JH
JR
6/20/24
JR
DOOR TYPES LEGEND DOOR SCHEDULE
1. REFER TO GENERAL NOTES ON SHEET G-101 FOR ADDITIONAL
REQUIREMENTS
2. REFER TO FLOOR PLANS FOR DOOR LOCATIONS.
3. CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES WITH DOOR
MANUFACTURER SPECIFICATIONS PRIOR TO FABRICATION OF ROUGH
OPENINGS.
4. CONTRACTOR TO VERIFY ACTUAL DOOR SIZES TO FIT FINISH OPENING
PRIOR TO FABRICATION OF DOOR AND FINISH OPENING.
5. REFER TO DOOR TYPES LEGEND FOR GLAZING.
6. REFER TO T24 REPORT FOR GLAZING ENERGY REQUIREMENTS
7. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS
8. REFER TO FINISH SCHEDULE ON A-501 AND A-502 FOR DOOR AND FRAME
PAINT COLORS.
DOOR GENERAL NOTES
1. EGRESS DOOR.
2. EQUIPPED W/PANIC HARDWARE. .
3. INCLUDES SAFETY GLAZING.
4. FIRE-RATED DOOR ASSEMBLY. VISION PANELS OR LITES TO RECEIVE WIRE
GLASS.
5. LOUVERED DOOR.
6. EXISTING DOOR TO CHANGE SWING DIRECTION FROM IN TO OUT, ADJUST
AND REINSTALL HARDWARE AS NEEDED.
7. CLOSER BUT NO LATCH, PUSH PLATE PROVIDED.
8. PROVIDE PRIVACY LOCKSET TO MATCH EXISTING.
DOOR REMARKS
NO.
SIZE DOOR FRAME HARDWARE
GROUP
DETAIL
REMARKSWIDTH HEIGHT THICKNESS TYPE MAT'L TYPE MAT'L SILL JAMB HEAD
100A 3' - 0" 8' - 0" 1 3/4" 1D ALUM F1 ALUM 01 1/A-901 6/A-901 6/A-901 1,2,3
111B 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 02 2/A-901 2/A-901 3
114 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 03 2/A-901 2/A-901 1,2,3
122A 3' - 0" 7' - 0" 1 3/4" 1D ALUM F1 ALUM 04 1/A-901 6/A-901 6/A-901 1,2,3
122B 3' - 0" 7' - 0" 1 3/4" 1D ALUM F1 ALUM 05 1/A-901 6/A-901 6/A-901 2,3
126 3' - 0" 7' - 0" 1 3/4" 1A ALUM F1 ALUM 06 1/A-901 6/A-901 6/A-901
214 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 07 3
224 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 03 2/A-901 2/A-901 1,2,3
E111A 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST 6,8
E222 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST 6,7
WINDOW AND STOREFRONT TYPES
DOOR MATERIAL LEGEND
1. REFER TO GENERAL NOTES ON SHEET G-101 FOR ADDITIONAL
REQUIREMENTS
2. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS.
3. CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES WITH WINDOW
MANUFACTURER SPECIFICATIONS PRIOR TO FABRICATION OF ROUGH
OPENINGS.
4. CONTRACTOR TO VERIFY ACTUAL WINDOW SIZES TO FIT FINISH OPENING
PRIOR TO FABRICATION OF WINDOW AND FINISH OPENING.
5. HEAD HEIGHT MEASURED FROM FF UNLESS NOTED OTHERWISE.
6. REFER TO ENERGY COMPLIANCE REPORTS FOR U-FACTOR, SHGC AND
ADDITIONAL WINDOW REQUIREMENTS.
7. ALL EXTERIOR GLAZING IS DOUBLE PANE UNLESS OTHERWISE NOTED.
8. REFER TO STOREFRONT AND WINDOW TYPES LEGEND FOR GLAZING.
9. ALL GLAZING IS TO BE SAFTEY GLAZING (TEMPERED).
10. ALL OPERABLE WINDOWS ARE TO BE PROVIDED WITH LIMITERS
RESTRICTING WINDOW PROJECTIONS TO 4".
11. ALL OPERABLE WINDOWS ARE TO BE PROVIDED WITH WINDOW SCREENS.
WINDOW GENERAL NOTES
1
1
1
9/13/24
(E) CONCRETE SLAB
ALUMINUM
STOREFRONT FRAME
BEYOND
ALUMINUM
STOREFRONT DOOR
FRAME & DOOR
HEAD/JAMB SIMILAR
GYPSUM BOARD
WALL FRAMING
HOLLOW METAL DOOR SYSTEM
DOOR PANEL
10 d. x 2.5" NAILS PER MANUF.
FLOOR FINISH
MAX.
1/2"
(E) METAL STUD WALL
FRAMING
ALUMINUM
STOREFRONT
EQ EQ
(E) GYP. BD.
NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN.
(E) VERIFY IN FIELD
+4'-0" A.F.F.
BACKER ROD AND
SEALANT, TYP
5/8" CASING BEAD
TRIM
(E) CONCRETE SLAB
1/2" SHIM
ALUMINUM STOREFRONT
FRAME BEYOND
BACKER ROD AND
SEALANT, TYP
ALUMINUM STOREFRONT
1/2" SHIM
5/8" GYP. BD.
ALUMINUM STOREFRONT
EQ.EQ.
3/4" PLY
3-5/8" LIGHT GUAGE
METAL STUD. 362S162-33
5/8" "J" CASING
BEAD TRIM
BACKER ROD AND
SEALANT, TYP
ALUMINUM
STOREFRONT
(E) SOFFIT FRAMING
EQ EQ
GYP. BD.
EXISTING SOFFIT FRAMING TO REMAIN
(E) VERIFY IN FIELD
BACKER ROD AND
SEALANT, TYP
NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN.
(E) STEEL STUD
FRAMING TO REMAIN
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
3" = 1'-0"
DO
O
R
&
W
I
N
D
O
W
D
E
T
A
I
L
S
A-901
JH
JR
6/20/24
JR
SCALE: 3" = 1'-0"A-601 A-901
INT. STOREFRONT DOOR1
SCALE: 3" = 1'-0"A-901
INT. DOOR -HEAD/JAMB2
SCALE: 3" = 1'-0"A-601 A-901
STOREFRONT SILL @(E) WALL4
SCALE: 3" = 1'-0"A-601 A-901
ALUM. STOREFRONT SILL @FLOOR3
SCALE: 3" = 1'-0"A-601 A-901
ALUM. STOREFRONT JAMB/HEAD6
SCALE: 3" = 1'-0"A-601 A-901
STOREFRONT HEAD @ (E) SOFFIT5
9/13/24
(E) STEEL STUD TO REMAIN
(E) GYP BD TO REMAIN
(N) 5/8" GYP BD
(E) VERIFY IN FIELD
3-5/8" LIGHT GUAGE MTL STUD
CORNER BEAD
3-5/8" LIGHT GUAGE MTL STUD
SCHEDULED FINISH, TYP.
HILTI X-U 72 PB S36 W/ FLAT WASHER
@32" O.C. & 5" & 10" OF ENDS, 1" MIN
EMBED (ICC-ES ESR 2268)
(E) CONC. FLOOR
BOTTOM CHANNEL
NOTE:
1. WALL FRAMING TO ACCOMODATE 5LB/SF INT. LOAD.
2. LINE CAULK BETWEEN WALL AND RUNNER (TYP)
METAL STUD WALL
FRAMING. 362S162-33
ACOUSTICAL CEILING
PANEL
NOTE:
WALL FRAMING TO ACCOMODATE
5LB/SF INT. LOAD.
WALL SOUND INSULATION
ABOVE CLNG.
0' - 6"
LIGHT GUAGE METAL STUD
(362S162-33) BRACE TO STRUCTURE
ABOVE @48" O.C. STAGGERED
TOP TRACK 362T162-33
NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN.
SIMPSON A34 ATTACHED W/ SELF-
TAPPING SCREWS TO SIDE OF BRACE
AND TOP OF TRACK.
ATTACH BRACE TO TRACK WITH #8
SELF-TAPPING SCREWS. ATTACH
TRACK TO EXISTING ROOF DECK
(E) FRAMING
2 #10 SCREWS @ 24" O.C.
2X4 20 GA SOFFIT FRAMING @
16" O.C. - REFER TO RCP FOR
SOFFIT TYPES
2X BRACING @ 4'-0" O.C. ATTACH
TO STRUCTURAL FRAMING W/
"SIMPSON" DTC (SLOTTED LEG VERT J)
@ EACH JOIST OR 24" O.C. @ BLOCKING
SCHEDULED CEILING
WALL PER PLAN
20 GA 2X4 MTL STUD OR 2X6
BLOCKING PER FRAMING
CORNER BEAD
SCHEDULED FINISH - TYP
2 - #10 SCREWS @24" O.C.
REFER TO RCP
REFER TO RCP
0' - 1"
0' - 6"
A-902
7
A-902
8
A-902
2
(E) ACOUSTICAL CEILING
TILE, REFER TO RCP
NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN.
(E) ACT
+12'-2" A.F.F.
(E) STEEL STUD
TO REMAIN
(E) CONC. SLAB
ACOUSTICAL LAY-IN
TILE CEILING.
REFER TO RCP
GYP. B.D CEILING.
REFER TO RCP
+10'-0" A.F.F.
+9'-0" A.F.F.
+8'-5" A.F.F.
EXISTING BULK HEAD
TO BE REMOVED
(E) MTL. STUD KICKERS
@48" O.C. BRACED TO
STRUCTURE ABOVE.
V.I.F.
5/8" GYP. BD. CEILING.
REFER TO RCP
GYP. BD.
+8'-5"
3-5/8" LIGHT GUAGE
MTL STUD.
362S162-33
CORNER
BEAD+10'-0"
5/8" GYP. BD.
LIGHT GUAGE METAL
STUD (362S162-33)
BRACE TO WALL
(E) STEEL STUD TO REMAIN
(E) GYP BD TO REMAIN
5/8" GYP BD. CEILING.
REFER TO RCP
3-5/8" LIGHT GUAGE
MTL STUD. 362S162-33
CORNER BEAD
(E) BULKHEAD HT. +8'-5"
VERIFY IN FIELD
ACT
+9'-0" A.F.F.
NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN.
ACOUSTICAL CEILING TILE,
REFER TO RCP
LIGHT GUAGE METAL
STUD (362S162-33)
BRACE TO WALL
3-5/8" LIGHT GUAGE METAL
STUD. 362S162-33
NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN.
LIGHT GUAGE METAL STUD
(362S162-33) BRACE TO
STRUCTURE ABOVE @48"
O.C. STAGGERED
ALUMINUM
STOREFRONT
BACKER ROD AND
SEALANT, TYP
(E) METAL STUD SOFFIT
FRAMING TO REMAIN
GYP. BD. WHERE OCCURS.
FASTEN TO (E) SOFFIT
FRAMING. REFER TO RCP
NEW ACT WHERE OCCURS.
REFER TO RCP
5/8" GYP. BD.
CEILING
SOFFIT
REFER TO RCP REFER TO RCP
REFER TO RCP
REFER TO RCP
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DE
T
A
I
L
S
A-902
JH
JR
6/20/24
JR
SCALE: 3" = 1'-0"A-902
TYP. BULKHEAD3
SCALE: 3" = 1'-0"A-902 A-902
TYP. PARTITION TO FLOOR2
SCALE: 3" = 1'-0"A-902
PARTITION BRACING PARTIAL HT.1
SCALE: 1 1/2" = 1'-0"A-902
TYP. SOFFIT FRAMING6
SCALE: 3/4" = 1'-0"A-111 A-902
WALL SECTION -SHARED OFFICE10
SCALE: 3" = 1'-0"A-902 A-902
CEILING FRAMING 17
SCALE: 3" = 1'-0"A-902 A-902
CEILING FRAMING 28
SCALE: 1 1/2" = 1'-0"A-111 A-902
SOFFIT DETAIL12
9/13/24
1'
-
0
"
8"
ELEVATION
WOOD STUDS, REF. TO
STRUCTURAL
2X6 BLOCKING
CONNECT EACH END OF
BLOCKING TO STUD IN ANY
MEHTOD DETAILED BELOW AT
CONTRACTOR'S OPTION, U.O.N.
OFFSET AT EACH STUD BAY TO
AVOID FASTENER CONFLICT
USE:#10 WOOD SCREW MIN. TO ATTACH ACCESSORIES TO BLOCKING, U.O.N.
FOR: MIRRORS, FLAT SIGNS, TACKBOARDS, CHALKBOARDS, MARKER BOARDS,
BULLETIN BOARDS, FRAMED ARTWORK.
NOTES:
1. DO NOT CUT OR NOTCH STUDS TO INSTALL BLOCKING
2. VERIFY LENGTH, HEIGHT, QUANTITY, AND LOCATION FOR BLOCKING WITH
ARCHITECTURAL DETAILS AND ACCESSORY MANUFACTURER
3. EXTEND BLOCKING TO FIRST STUD PAST END OF ACCESSORY
4. REFER TO STRUCTURAL DETAILS FOR MINIMUM LOAD LIMITS ON BLOCKING
(AT 2X STUD ONLY)
(3) 16d END NAILS
2x STUD
2x6 BLOCK
(4) 8d TOE NAILS
1-TOP & BOTTOM
2-ON FACE FLUSH
W/ STUD
STUD, ANY
THICKNESS
2x6 BLOCK
STUD, ANY
THICKNESS
2x6 BLOCK
SIMPSON A21 TOP
& BOTTOM (2-8d
NAILS TO EACH
MEMBER)
METHOD A
METHOD B
METHOD C
A
A
SECTION A-A
PLAN
2X6 BLOCKING
WOOD STUDS
ELEVATION SECTION
PLAN
"SIMPSON" A35 AT EACH
END OF BLOCKING.
ALTERNATE TOP &
BOTTOM, TYP.
OFFSET BLOCKING AT
EACH STUD BAY TO
AVOID FASTENER
CONFLICT
WOOD STUDS, REF. TO
STRUCTURAL
4X6 BLOCKING
USE:#12 WOOD SCREW MIN. TO ATTACH
ACCESSORIES TO BLOCKING, U.O.N.
FOR: TOILET & BATH ACCESSORIES,
DOOR STOPS, DOOR HOLDERS,
CABINETS, DISPLAY CABINETS, TOILET
PARTITIONS
NOTES:
1. DO NOT CUT OR NOTCH STUDS TO INSTALL BLOCKING
2. VERIFY LENGTH, HEIGHT, QUANTITY, AND LOCATION FOR BLOCKING WITH
ARCHITECTURAL DETAILS AND ACCESSORY MANUFACTURER
3. EXTEND BLOCKING TO FIRST STUD PAST END OF ACCESSORY
4. REFER TO STRUCTURAL DETAILS FOR MINIMUM LOAD LIMITS ON BLOCKING
USE: # 14 WOOD SCREW MIN. OR 1/4"
DIAMETER WOOD SCREW MIN. TO ATTACH
ACCESSORIES TO BLOCKING, U.O.N.
FOR:HANDRAILS, GRAB BARS, SHOWER
SEATS, SHELF BRACKETS, COUNTERTOP
BRACKETS, URINAL SCREENS, WATER
HEATER STRAPS, SINK BRACKETS, ETC.
A
A
A-A
2"x3"x3/16", 20" LONG METAL SUPPORT W/90
DEGREE LEG 20" LONG BOLTED TO
COUNTER @ 30" O.C.
MIRROR
WALL FRAMING - REFER TO FLOOR PLAN
4" BACKSPLASH
SOLID-SURFACE COUNTERTOP PER SPEC
1/2" PLYWOOD O/2x4 FRAMING
SKIRT TO MATCH COUNTERTOP
SINK PER PLUMBING
METAL SUPPPORT BRACKET
W/(2) 1/2" BOLTS TO 2x4 COUNTER
TOP FRAMING
2x4 BLOCK SCREWED TO STUD BLOCK
WASTE PIPING - SEE PLUMBING PLAN
20 GA PLATE W/ 4 #10 SCREWS
WALL FINISH, REFER TO SCHEDULE
CLEAR ZONE, SEE DETAIL T-1.3/xxxx
WATER-RESISTANT GYPSUM BOARD
WALL FRAMING - REFER TO
FLOOR PLAN FOR WALL TYPES
CABINET
PROVIDE SLEEVE NUTS & SCREW
FASTENERS BETWEEN EACH
CABINET UNIT @ TOP & BOTTOM,
FRONT & BACK
BLOCKING AT CABINET TOP &
BOTTOM
GYPSUM BD WALL FINISH
(O/PLYWOOD SHEATHING PER
STRUCTURAL W.O.)
#10 W.S. @ 12" O.C. MIN (3) PER
CABINET TOP AND BOTTOM.
TOP OF UPPER CABINET
REF. TO INT. ELEVATIONS
0' - 3 255/256"
4" TYP
2'-0" TYP. UON
(E) GYPSUM BOARD
(E) WALL FRAMING - REFER TO
FLOOR PLAN FOR WALL TYPES
PROVIDE BLOCKING AT TOP &
BOTTOM OF ALL UPPER BASE, AND
FULL HEIGHT CABINETS, AND WALL
HUNG ACCESSORIES.
#14 X 3 1/2" F.H.W.S. @ 16"
O.C. MAX
#12 X 3" F.H.W.S.
CABINET PER INTERIOR
ELEVATIONS
RUBBER BASE
SCHEDULED FINISH FLOOR
6" X 1-1/4" X 16 GA.
CONTINUOUS TRACK NOTCH &
FASTEN TO STUDS W/ 4 #8
S.M.S.
(E) WALL FRAMING
(E) GYPSUM BOARD
BACKSPLASH
(WHERE OCCURS)
BLOCKING
LAMINATE
COUNTERTOP
FACE OF CABINET
TOP OF COUNTER
REF. TO INT. ELEVATIONS
Sink (per Plans);
Sealant around
perimeter
SECTION
Note:Provide backing in wall
framing as required for lower
and upper cabinet support
Stainless Steel
Countertop
Insulate exposed water
supply and drain pipes; there
shall be no sharp or abrasive
surfaces under sink.
PLAN
Remove Doors or
Pocket away provided
min. 30" clr. width met
30" MIN. CLR. WORKSPACE @ WORKSTATION
PER PLANS
Finish Side Panels, Typ.
Under Sink
Sink (per Plans); Verify
Basin Depth per Knee
Clearance; Off-center
Rear Drain; Install per
Manuf. Specifications
*Kitchen Accessibility Notes
1. The sink and work surface to be separate (30") components.
2. Base cabinet doors directly under the counter area, shall be
removable without the use of specialized tools or specialized
knowledge, or shall pocket away in order to provide clearance for a
wheelchair. The finish floor beneath the counter area shall be
extended to the rear panel.
3. With doors removed or pocketed away, toe and knee clearance to
comply with detail:
4. Faucet controls and operating mechanisms shall be operable with
one hand and shall not require tight grasping, pinching or twisting of
the wrist.
5. The force required to activate controls shall be no greater than 5
pound force (22.2N). Lever-operated, push-type and electronically
controlled mechanisms are examples of acceptable designs. Self-
closing valves are allowed if the faucet remains open for at least 10
seconds.
34" MAX.
Retractable hardware at
sink cabinet base; doors
pocket away or may be
removed*
Finish Interior Side
Panels
BETWEEN SIDE PANELS
MIN. 30" CLR.
4"
Under Sink
27" Min. Knee Clearance
ELEVATION
Finish Back and Insides of Cabinet
TO REAR OF CABINET
2' - 0"
Extend Finish Flooring Under Cabinet
GYPSUM BOARD
WALL FRAMING - REFER
TO FLOOR PLANS FOR
WALL TYPES
SEMI-RECESSED CABINET - ATTACH
PER MANUF. RECOMMENDATIONS.
WRAP GYPSUM BOARD INTO OPENING
MOUNT WITH OPERABLE PORTION
OF CABINET OR EXTINGUISHER
AT 48" MAX. A.F.F.
4" MAX
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DE
T
A
I
L
S
A-903
JH
JR
6/20/24
JR
SCALE: 1" = 1'-0"A-903
TYP. 2X BLOCKING2
SCALE: 1" = 1'-0"A-903
TYP. 4X BLOCKING1
SCALE: 1" = 1'-0"A-903
LAVATORY COUNTER8
SCALE: 3" = 1'-0"A-903
BASE CABINET4
SCALE: 3" = 1'-0"A-903
BASE CABINET ANCHORAGE3
SCALE: 3" = 1'-0"A-903
LAMINATE COUNTERTOP5
SCALE: 3/4" = 1'-0"A-413 A-903
ACC. KITCHEN WORKSTATION AND SINK9
SCALE: 3" = 1'-0"A-903
FIRE EXTINGUISHER7
9/13/24
SLOPE,
TYP.
WATERPROOF
MEMBRANE
FLOOR DRAIN - REFER
TO PLUMBING PLANS
SLOPE
2% MAX
DRAIN SET FLUSH WITH
FINISH FLOOR
CERAMIC TILE OVER
THINSET MORTAR AND
MORTAR BED
CARPET
1/4" - 3/8"
(IF > 1/4" HIGH, THEN
PROVIDE 1:2 BEVEL)
1/4"
LUXURY
VINYL TILE
FINISH PER
SCHEDULE
STRAIGHT EDGE
TRIM
(E) CONCRETE SLAB
MORTAR BED
CERAMIC FLOOR TILE
COVED CERAMIC FLOOR TILE
CERAMIC TILE, THINSET OVER CEMENT
BOARD OR M.R. GYP. BOARD AS SPECIFIED
REFER TO INTERIOR ELEVS
CERAMIC TILE BULL NOSE, THINSET OVER
CEMENT BOARD OR M.R. GYP. BOARD AS
SPECIFIED
NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN.
RESILIENT
BASE
WALL FINISH
1/2"
GYPSUM
WALL BOARD
FINISH FLOOR RESILIENT BASE
WALL FINISH
1/2"
GYPSUM
WALL BOARD
FINISH FLOOR
(E) CONCRETE
CURB, (N)
WHERE OCCURS
USE CONSTRUCTION
ADHESIVE TO
SECURE GWB TO
CONCRETE CURB
(E) CONC.
SLAB
(E) CONC.
SLAB
WITHOUT CURB WITH CURB
3/8" THROUGH-BOLTS
WITH WASHERS ON
BACKSIDE. TYP 6 MIN.
CUT AROUND
MOUNTING PLATE
BACKING PER
STRUCTURAL
FRAMING STUD
GYPSUM
BOARD
MOUNTING
PLATE
WALL MOUNTED
DRINKING FOUNTAIN
MOUNTING STUDS
0' - 8"
C 40884
10-31-25
RENEWAL DATE
A
T
C
E
TIHCRADESNECIL
S
T
A
T
E OF C A L I F O R NI
J O N A T H AN
K
C
U
OH
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
2000577-04
As indicated
DE
T
A
I
L
S
A-904
JH
JR
6/20/24
JR
SCALE: 3" = 1'-0"A-904
FLOOR DRAIN2
SCALE: 6" = 1'-0"A-904
CARPET TO LVT TRANSITION5
SCALE: 3" = 1'-0"A-904
BASE - INTERIOR - CT
4
SCALE: 3" = 1'-0"A-904
GWB TERMINATION AND BASE1
SCALE: 3" = 1'-0"A-904
DUAL WALL MOUNT FOUNTAIN6
9/13/24
MECHANICAL GENERAL NOTES
1 COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES:
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC): PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS
(CCR)
2022 CALIFORNIA BUILDING CODE (CBC): PART 2, TITLE 24 CCR
2022 CALIFORNIA ELECTRICAL CODE (CEC): PART 3, TITLE 24 CCR
2022 CALIFORNIA MECHANICAL CODE (CMC): PART 4, TITLE 24 CCR
2022 CALIFORNIA PLUMBING CODE (CPC): PART 5, TITLE 24 CCR
2022 CALIFORNIA ENERGY CODE (CENC): PART 6, TITLE 24 CCR
2022 CALIFORNIA FIRE CODE (CFC): PART 9, TITLE 24 CCR
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN): PART 11, TITLE 24 CCR
REPORT DEFICIENCIES WITHIN THIRTY (30) DAYS UPON AUTHORIZATION TO PROCEED.
2 THESE DRAWINGS ARE A GENERAL GRAPHIC PRESENTATION OF THE WORK. DUCTWORK, PIPING, AND
EQUIPMENT, AS SHOWN, ARE SCHEMATIC. FABRICATE AND INSTALL BASED ON ACTUAL FIELD
MEASUREMENT. COORDINATE WITH OTHER TRADES. ADHERE TO LOCATIONS AS CLOSELY AS
POSSIBLE, VARY RUNS OR SHAPE OF DUCTWORK AS REQUIRED TO MEET STRUCTURAL AND OTHER
INTERFERENCES AS REQUIRED BY THE ARCHITECT. PROVIDE A COMPLETE SET OF SHOP DRAWINGS
REFLECTING ACTUAL DIMENSIONS, ACCESS REQUIREMENTS, AND DETAILS BASED UPON THE ACTUAL
EQUIPMENT PROCURED. MAINTAIN AN UP TO DATE SET OF AS-BUILT DRAWINGS AT THE JOB SITE.
3 THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL ITEMS RELATED TO MECHANICAL SYSTEMS
WITH THE WORK OF OTHER TRADES BEFORE PROCEEDING WITH PROCURING OR FABRICATION OF
EQUIPMENT, DUCTWORK, PIPING ETC. ITEMS TO BE COORDINATED SHALL INCLUDE BUT ARE NOT
LIMITED TO THE FOLLOWING:
GRILLES, REGISTERS AND DIFFUSERS SHALL BE COORDINATED WITH THE REFLECTED CEILING PLAN.
DUCTWORK LOCATIONS AND POTENTIAL INTERFERENCES WITH STRUCTURAL MEMBERS, FRAMING, FIRE
SPRINKLER LINES, PLUMBING WASTE LINES, CABLE TRAYS AND CONDUIT.
ACCESS TO VOLUME DAMPERS FOR BALANCING. ACCESS TO ALL EQUIPMENT, AS WELL AS PLATFORM
AND CURB LOCATIONS.
4 REVIEW ALL DRAWINGS AND SPECIFICATIONS INCLUDING ARCHITECTURAL, STRUCTURAL, CIVIL,
MECHANICAL, PLUMBING, AND ELECTRICAL. ANY QUESTIONS SHALL BE BROUGHT UP, IN WRITING, TO
THE ATTENTION OF THE ENGINEER BEFORE THE START OF CONSTRUCTION.
5 REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF DIFFUSERS,
REGISTERS, GRILLES, AND ACCESS PANELS.
6 ALL DUCT DIMENSIONS, AS SHOWN ON MECHANICAL DRAWINGS ARE CLEAR INSIDE DIMENSIONS.
INCREASE OUTER DUCT DIMENSION AS REQUIRED TO ACCOUNT FOR THE THICKNESS OF INTERNAL
LINING WHERE APPLICABLE.
7 INSULATION AND FLEXIBLE DUCT SHALL COMPLY WITH STATE FIRE MARSHALL CRITERIA AND SHALL NOT
EXCEED FLAME SPREAD OF 25 AND SMOKE DEVELOPED OF 50 PER ASTM-84, NFPA-223, AND UL 723.
8 INSULATE PIPING AND DUCTWORK IN ACCORDANCE TO THE GOVERNING CODES.
9 ALL SQUARE ELBOWS IN SUPPLY DUCTWORK SHALL HAVE TURNING VANES. PROVIDE MANUAL VOLUME
DAMPER AT EACH BRANCH DUCT TAKE-OFF SERVING EACH AIR TERMINAL DEVICE. PROVIDE BALANCING
DAMPERS FOR EACH MAIN DUCT TAKE-OFF IN ACCORDANCE TO SMACNA IN ORDER TO ASSURE A
COMPLETELY BALANCED SYSTEM.
10 MATERIALS EXPOSED WITHIN ANY SPACE BEING USED AS AN AIR PLENUM SHALL BE NON COMBUSTIBLE
OR SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE DEVELOPED INDEX NOT
GREATER THAN 50, WHEN TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ONE OF THE
FOLLOWING TEST METHODS: NFPA 255, METHOD OF TEST OF SURFACE BURNING CHARACTERISTICS OF
BUILDING MATERIALS, ASTM E84, SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, OR UL
723, TEST FOR SURFACE BURNING CHARACTERISTIC OF BUILDING MATERIALS.
PLUMBING GENERAL NOTES
1 COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES:
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC): PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS
(CCR)
2022 CALIFORNIA BUILDING CODE (CBC): PART 2, TITLE 24 CCR
2022 CALIFORNIA ELECTRICAL CODE (CEC): PART 3, TITLE 24 CCR
2022 CALIFORNIA MECHANICAL CODE (CMC): PART 4, TITLE 24 CCR
2022 CALIFORNIA PLUMBING CODE (CPC): PART 5, TITLE 24 CCR
2022 CALIFORNIA ENERGY CODE (CENC): PART 6, TITLE 24 CCR
2022 CALIFORNIA FIRE CODE (CFC): PART 9, TITLE 24 CCR
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN): PART 11, TITLE 24 CCR
REPORT DEFICIENCIES WITHIN THIRTY (30) DAYS UPON AUTHORIZATION TO PROCEED.
2 NO PLUMBING SHALL BE INSTALLED UNTIL ALL REQUIRED PLUMBING PLAN CHECK PERMITS AND
APPROVALS HAVE BEEN OBTAINED FROM ALL REQUIRED AGENCIES.
3 LAVATORY FAUCETS, SINK FAUCETS (NOT INCLUDING SERVICE SINK FAUCETS OR FAUCETS
DESIGNATED AS INSTITUTIONAL) SHALL MEET THE FLOW REQUIREMENTS OUTLINED IN THE APPLIANCE
EFFICIENCY STANDARDS.
4 COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF PLUMBING FIXTURES
AND DRAINS.
5 PROVIDE ALL TAILPIECES, TRAPS, STOPS, AND SUPPLY PIPES TO LAVATORIES DESIGNED AS
ACCESSIBLE, WITH PREFORMED INSULATION JACKET.
6 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF WALLS, ROOFS, FOOTINGS,
FLOORS, INCLUDING ALL SAW CUTTING AND CORE DRILLING. COORDINATE ALL SAW CUTTING AND CORE
DRILLING WITH STRUCTURAL DRAWINGS. ANY CUTTING AND DRILLING REQUIRED OF STRUCTURAL
ELEMENTS THAT IS NOT SPECIFICALLY SHOWN ON THE PLANS SHALL BE BROUGHT TO THE ARCHITECTS
ATTENTION PRIOR TO CUTTING AND DRILLING. CONTRACTOR SHALL SUBMIT PROPOSED LOCATION AND
SIZES OF SUCH CUTTING AND DRILLING FOR THE ARCHITECTS AND STRUCTURAL ENGINEERS
APPROVAL.
7 COORDINATE INSTALLATION OF ALL EQUIPMENT AND PIPING WITH OTHER TRADES PRIOR TO
INSULATION. ENSURE THAT ALL CONTROL DEVICES, SHUT-OFF VALVES, ETC. ARE ACCESSIBLE FOR
MAINTENANCE. WHERE ACCESS PANELS IN FINISHED SPACES, OTHER THAN THAT SHOWN,
CONTRACTOR SHALL PROVIDE AND COORDINATE EXACT LOCATION OF PANELS WITH ARCHITECT PRIOR
TO INSTALLATION.
8 ANY STRUCTURAL FIREPROOFING DAMAGED DURING INSTALLATION OF PLUMBING EQUIPMENT, PIPING,
ETC. SHALL BE REPAIRED AT NO COST TO THE OWNER. REPAIRS SHALL BE AS DIRECTED BY THE
ARCHITECT.
9 NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE PER 2022 CPC
609.10. THE METHOD TO BE FOLLOWED SHALL BE THAT PRESCRIBED BY THE HEALTH AUTHORITY OR, IN
CASE NO METHOD IS PRESCRIBED BY IT, THE FOLLOWING:
A)THE PIPE SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE WATER UNTIL POTABLE WATER APPEARS
AT THE POINTS OF OUTLET.
B)THE SYSTEM OR PARTS THEREOF SHALL BE FILLED WITH A WATER-CHLORINE SOLUTION CONTAINING
NOT LESS THAN 50 PARTS PER MILLION OF CHLORINE, AND THE SYSTEM OR PART THEREOF SHALL BE
VALVED-OFF AND ALLOWED TO STAND FOR 24 HOURS; OR, THE SYSTEM OF PART THEREOF SHALL BE
FILLED WITH A WATER-CHLORINE SOLUTION CONTAINING NOT LESS THAN 200 PARTS PER MILLION OF
CHLORINE AND ALLOWED TO STAND FOR 3 HOURS.
C)FOLLOWING THE ALLOWED STANDING TIME, THE SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE
WATER UNTIL THE CHLORINE RESIDUAL IN THE WATER COMING FROM THE SYSTEM DOES NOT EXCEED
THE CHLORINE RESIDUAL IN THE FLUSHING WATER.
D)THE PROCEDURE SHALL BE REPEATED WHERE IT IS SHOWN BY BACTERIOLOGICAL EXAMINATION MADE
BY AN APPROVED AGENCY THAT CONTAMINATION PERSISTS IN THE SYSTEM.
MECHANICAL LEGEND
SYMBOL ABBREVIATION DESCRIPTION
Ø DIA DIAMETER
ɸ ELECTRICAL PHASE
CEILING MOUNTED SUPPLY OR OUTSIDE AIR DIFFUSER
CEILING MOUNTED RETURN AIR GRILLE
CEILING MOUNTED EXHAUST AIR GRILLE
SIDEWALL MOUNTED SUPPLY AIR DIFFUSER, RETURN
AIR GRILLE, LOUVER
24X12, 24X12 FO RECTANGULAR, FLAT OVAL DUCT
24X12L, 12ØL LINED DUCT
RECTANGULAR SUPPLY / OA, RETURN, EXHAUST /
RELIEF DUCT PASSING THROUGH PLAIN OF VIEW
RECTANGULAR SUPPLY / OA, RETURN, EXHAUST /
RELIEF DUCT TURNING DOWN
12Ø ROUND DUCT
ROUND DUCT TURNING DOWN, ROUND DUCT TURNING
UP
90° ELBOW WITH TURNING VAINS
FLEXIBLE DUCT 60" MAX LENGTH
FC FLEXIBLE CONNECTION
VD MANUAL VOLUME DAMPER
CVD CABLE OPERATED VOLUME DAMPER
ACCESS CLEARANCE
POC OR POD POINT OF CONNECTION, POINT OF DISCONNECTION
ITEMS RELATED TO THE MECHANICAL SYSTEM TO BE
REMOVED
MECHANICAL ABBREVIATIONS
AC AIR CONDITION, AIR CONDITIONING, AIR
CONDITIONED HP HORSE POWER
ABV ABOVE HVI HOME VENTILATING INSTITUTE
AFF ABOVE FINISHED FLOOR HZ HERTZ
AFUE ANNUAL FUEL UTILIZATION EFFICIENCY IDU INDOOR UNIT
AHJ AUTHORITY HAVING JURISDICTION IWC INCHES OF WATER COLUMN
AHU AIR HANDLING UNIT KW KILOWATT
ALUM ALUMINUM LBS POUNDS
AMCA AIR MOVEMENT AND CONTROL
ASSOCIATION LWT LEAVING WATER TEMPERATURE
AMB AMBIENT MBH 1000 BRITISH THERMAL UNITS PER HOUR
AP ACCESS PANEL MCA MINIMUM CIRCUIT AMPS
ARCH ARCHITECT, ARCHITECTURAL MFGR MANUFACTURE OR MANUFACTURER
ARI AMERICAN REFRIGERATION INSTITUTE MIN MINIMUM
ASHRAE
AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AND AIR CONDITIONING
ENGINEERS
MUA MAKE-UP AIR
BDD BACK DRAFT DAMPER (N)NEW
BOD BASIS OF DESIGN NL NOT LISTED
BEL BELOW NOM NOMINAL
BHP BREAK HORSE POWER NTS NOT TO SCALE
BLDG BUILDING OA OUTSIDE AIR
BTUH BRITISH THERMAL UNIT PER HOUR OAI OUTSIDE AIR INTAKE
CA COMBUSTION AIR OBD OPPOSED BLADE DAMPER
CD CONDENSATE DRAIN ODU OUTDOOR UNIT
CFD CEILING FIRE DAMPER OSHPD OFFICE OF STATEWIDE HEALTH PLANNING
AND DEVELOPMENT
CFM CUBIC FEET PER MINUTE PD PRESSURE DROP
CONT CONTINUATION PSI POUNDS PER SQUARE INCH
CSD CEILING SMOKE DAMPER RA RETURN AIR
DB DRY BULB TEMPERATURE REFRIG REFRIGERANT, REFRIGERATION
DN DOWN RM ROOM
DSA DIVISION OF THE STATE ARCHITECT RPM REVOLUTIONS PER MINUTE
DTR DOWN THROUGH ROOF SA SUPPLY AIR
(E)EXISTING SEER SEASONAL ENERGY EFFICIENCY RATION
EA EXHAUST AIR SHT SHEET
EC EVAPORATIVE COOLER SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
EDB ENTERING DRY BULB TEMPERATURE SOV SHUT OFF VALVE
EER ENERGY EFFICIENCY RATIO SP STATIC PRESSURE
EFF EFFICIENCY SS STAINLESS STEEL
ELEC ELECTRICAL SSE STEADY STATE EFFICIENCY
ESP EXTERNAL STATIC PRESSURE SST SATURATED SUCTION TEMPERATURE
EWB ENTERING WET BULB TEMP TEMPORARY, TEMPERATURE
EWT ENTERING WATER TEMPERATURE TSP TOTAL STATIC PRESSURE
FA FROM ABOVE TYP TYPICAL
FC FLEXIBLE CONNECTION TXV THERMAL EXPANSION VALVE
FD FIRE DAMPER UON UNLESS OTHERWISE NOTED
FLA FULL LOAD AMPS UTR UP TO OR UP THROUGH ROOF
FPM FEET PER MINUTE VD VOLUME DAMPER
FSC FAN SPEED CONTROLLER VEX VEHICLE EXHAUST SYSTEM
FSD FIRE/SMOKE DAMPER VRF VARIABLE REFRIGERANT VOLUME
GA GAGE, GAUGE WB WET BULB TEMPERATURE
GALV GALVANIZED WC WATER COLUMN
GPM GALLONS PER MINUTE WG WATER GAUGE
GYP GYPSUM WT WEIGHT EXPRESSED IN POUNDS
HD HEAD
PLUMBING ABBREVIATIONS
ABV ABOVE HD HEAD
ADA AMERICANS WITH DISABILITIES ACT HP HORSE POWER
AFF ABOVE FINISHED FLOOR HZ HERTZ
AG ABOVE GRADE IE INVERT ELEVATION
AHJ AUTHORITY HAVING JURISDICTION IWC INCHES OF WATER COLUMN
ALUM ALUMINUM KW KILOWATTS
AMB AMBIENT LAV LAVATORY
AMP AMPERAGE LBS POUNDS
ARCH ARCHITECT, ARCHITECTURAL LWT LEAVING WATER TEMPERATURE
BEL BELOW MAX MAXIMUM
BF BELOW FLOOR MBH 1000 BRITISH THERMAL UNITS PER HOUR
BG BELOW GRADE MCA MINIMUM CIRCUIT AMPS
BFP BACKFLOW PREVENTOR MECH MECHANICAL
BLDG BUILDING MFGR MANUFACTURE OR MANUFACTURER
BOD BASIS OF DESIGN MIN MINIMUM
BTUH BRITISH THERMAL UNIT PER HOUR MU MAKE-UP
CA COMBUSTION AIR (N)NEW
CD CONDENSATE DRAIN NOM NOMINAL
CFH CUBIC FEET PER HOUR NPS NOMINAL PIPE SIZE
CONN CONNECTION NTS NOT TO SCALE
CONT CONTINUATION OPT OPERATING
CI CAST IRON OSHPD OFFICE OF STATEWIDE HEALTH PLANNING
AND DEVELOPMENT
CP CHROME PLATED PD PRESSURE DROP
DFU DRAINAGE FIXTURE UNITS PH PHASE
DN DOWN PSI POUNDS PER SQUARE INCH
DSA DIVISION OF THE STATE ARCHITECT PW PROCESS WASTE
(E)EXISTING RM ROOM
EC EVAPORATIVE COOLER RPM REVOLUTIONS PER MINUTE
EFF EFFICIENCY SDL STORM DRAIN LEADER
ELEC ELECTRICAL SDO STORM DRAIN OVERFLOW
EQPT EQUIPMENT SHT SHEET
EWT ENTERING WATER TEMPERATURE SOV SHUT OFF VALVE
FA FROM ABOVE SS STAINLESS STEEL
FC FLEXIBLE CONNECTION TEMP TEMPORARY, TEMPERATURE
FLA FULL LOAD AMPS TYP TYPICAL
FLR FLOOR UON UNLESS OTHERWISE NOTED
FPS FEET PER SECOND UTR UP TO OR UP THROUGH ROOF
FR FROM V VENT
FT FLUSH TANK VAC VACUUM
FV FLUSH VALVE VTR VENT THROUGH ROOF
GA GAGE OR GAUGE WC WATER CLOSET
GALV GALVANIZED W WASTE
GPC GALLONS PER CYCLE W/WITH
GPF GALLONS PER FLUSH W/O WITHOUT
GPM GALLONS PER MINUTE WSFU WATER SUPPLY FIXTURE UNIT
GYP GYPSUM WT WEIGHT EXPRESSED IN POUNDS
GW GREASE WASTE
SHEET INDEX
SHEET NUMBER SHEET TITLE
MP-000 MECHANICAL & PLUMBING GENERAL
MP-001 MECHANICAL & PLUMBING SCHEDULES
MP-002 MECHANICAL & PLUMBING DETAILS
EC-000 ENERGY COMPLIANCE DOCUMENTATION
MPD-101 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN
MPD-102 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN
MP-200 MECHANICAL & PLUMBING FIRST FLOOR PLAN
MP-300 MECHANICAL & PLUMBING SECOND FLOOR PLAN
PLUMBING LEGEND
SYMBOL ABBREVIATION DESCRIPTION
BALL VALVE
BFV BUTTERFLY VALVE
CAP
CHECKVALVE
COTG CLEAN OUT THROUGH GRADE
Ø DIA DIAMETER
ɸ ELECTRICAL PHASE
FCO FLOOR CLEAN OUT
SHUT OFF VALVE IN PIPE DROP OR PIPE RISER
YB SHUT OFF VALVE IN YARD BOX
STRAINER
TPV TRAP PRIMER VALVE
UNION
PIPE DOWN
PIPE UP
PIPE TEE DOWN
PIPE INTERSECTION
PLUG VALVE ELEVATION VIEW
PV PLUG VALVE PLAN VIEW
POC OR POD POINT OF CONNECTION OR POINT OF DISCONNECT
PRV PRESSURE REDUCING OR REGULATOR VALVE
WCO WALL CLEANOUT
CW COLD WATER
CD CONDENSATE DRAIN
HW HOT WATER
V SANITARY VENT
TP TRAP PRIMER
S/W WASTE (ABOVE GRADE)
S/W WASTE (BELOW GRADE)
S/W EXISTING WASTE
WCO
CD
TP TP
PROJECT TEAM LIST
TITLE NAME DESK NUMBER EMAIL ADDRESS
PROJECT MANAGER DENVER STANGER 805.540.5388 DSTANGER@3CENG.COM
MECHANICAL DESIGNER DENVER STANGER 805.540.5388 DSTANGER@3CENG.COM
PLUMBING DESIGNER RANDY CARMINATI 805.540.3363 EXT 319 RCARMINATI@3CENG.COM
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
L
e
a
d
S
h
e
e
t
s
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
ME
C
H
A
N
I
C
A
L
&
P
L
U
M
B
I
N
G
G
E
N
E
R
A
L
MP-000
COMMERCIAL GRILLE, REGISTER, DIFFUSER, LOUVER SCHEDULE
TAG TYPE MAKE MODEL
BORDER TYPE
CONSTRUCTION FINISH IMAGE REMARKS INSTALLATION
DETAILGYP BOARD CEILING
OR WALL
LAY-IN
CEILING
CEILING
SUPPLY TITUS TDC 1 3 STEEL WHITE
MECHANICAL CONTRACTOR SHALL
COORDINATE WITH THE GENERAL
CONTRACTOR AND FRAMING CONTRACTOR
TO INSURE OPENINGS IN HARD CEILINGS
AND WALLS ARE CORRECTLY SIZED TO
ACCOMMODATE THE SPECIFIED BORDER
TYPE. NO EXCEPTIONS
3/MP-002
CEILING OR
SIDEWALL
RETURN AND
EXHAUST
TITUS 350RL 1 3 STEEL WHITE
MECHANICAL CONTRACTOR SHALL
COORDINATE WITH THE GENERAL
CONTRACTOR AND FRAMING CONTRACTOR
TO INSURE OPENINGS IN HARD CEILINGS
AND WALLS ARE CORRECTLY SIZED TO
ACCOMMODATE THE SPECIFIED BORDER
TYPE. NO EXCEPTIONS
SEE 3/MP-002 FOR
DUCTED
EXHAUST AIR
GRILLES
SEE 4/MP-002 FOR
PLENUM RETURN
AIR GRILLES
CEILING SUPPLY DEFLECTION LEGEND (EXCEPT FOR 4-WAY DEFLECTION, SHADING INDICATES ACTIVE SECTION OF DIFFUSER)
2-WAY CORNER 2-WAY OPPOSITE 1-WAY3-WAY4-WAY
12x12S1400
NECK SIZE (length x width or length x height)
CFMFDFD = FIRE DAMPER
FSD = FIRE/SMOKE DAMPER
OAI = OUTSIDE AIR INTAKE
X"Ø = INLET SIZE (IF APPLICABLE)
DIFFUSER, GRILLE, LOUVER
MARK: S = SUPPLY; R = RETURN;
E = EXHAUST; T = TRANSFER;
L = LOUVER; O = OUTSIDE AIR
S1S1S1S1
R1
E1
PLUMBING FIXTURE SCHEDULE
TAG FIXTURE
BRANCH SIZE
ELECTRICAL MODEL & FITTINGS
W V CW HW
DF-1 DRINKING FOUNTAIN -
ACCESSIBLE 2"1-1/2"1/2"NA NA
DUAL HEIGHT DRINKING FOUNTAIN WITH BOTTLE FILLER, HAWS #1117LN-1920, IN
WALL MOUNTED, STEEL MOUNTING PLATE, STAINLESS STEEL BOTTLE FILLER,
PROVIDE WITH STOPS AND SUPPLIES, INSTALL PER ACCESSIBLE FACILITY
REQUIREMENTS.
IMS-1 ICE MAKER SUPPLY NA NA 1/2"NA NA OATEY #39152, 6"X6"X3-3/8" PLASTIC BOX RECESSED IN WALL W/BRASS QUARTER
TURN VALVE. PROVIDE WITH WATER HAMMER ARRESTOR.
LAV-1 LAVATORY -
ACCESSIBLE 2"1-1/2"1/2"1/2"BATTERY
WALL MOUNTED, AMERICAN STANDARD #0356.421, VITREOUS CHINA, WHITE. SLOAN
FAUCET #EBF-85, 0.35 GPM, SENSOR OPERATED. PROVIDE STOPS, SUPPLIES, C.P.
BRASS "P" TRAP, & WATTS WALL SUPPORT #TCA-411.
S-1 SINK 2"1-1/2"1/2"1/2"NA
COUNTER MOUNTED, JUST #SL-ADA 2131-A65-J, 21-1/4"X31"X6-1/2" 18 GA.
STAINLESS, SINGLE BOWL. PROVIDE WITH T&S BRASS FAUCET #S-2770, STRAINER,
STOPS, SUPPLIES & C.P. BRASS "P" TRAP.
UR-1 URINAL 2"1-1/2"1-1/4"NA BATTERY
WALL MOUNTED, AMERICAN STANDARD PINTBROOK #6002.001, SENSOR OPERATED,
0.125 GPF, 14-7/16"X14-5/16"X22-5/8", VITREOUS CHINA, WHITE. PROVIDE WITH
SLOAN "SOLIS" FLUSH VALVE #8186, 0.125 GPF.
WC-1 WATER CLOSET -
ACCESSIBLE 3"2"1-1/4"NA BATTERY
FLOOR MOUNTED, AMERICAN STANDARD MADERA #3043.001, ELONGATED, SENSOR
OPERATED, 26-3/4"X14"X17" RIM, VITREOUS CHINA, WHITE. PROVIDE WITH SLOAN
FLUSH VALVE #8111-1.1-OR, 1.1 GPF AND & BEMIS OPEN FRONT SEAT
#1955SSCT-000. INSTALL PER ACCESSIBLE FACILITIES REQUIREMENTS, LOCATE
HANDLE ON WIDE SIDE OF FIXTURE
WC-2 WATER CLOSET 3"2"1-1/4"NA BATTERY
FLOOR MOUNTED, AMERICAN STANDARD MADERA #2234.001, ELONGATED, SENSOR
OPERATED, 26-3/4"X14"X15" RIM, VITREOUS CHINA, WHITE. PROVIDE WITH SLOAN
FLUSH VALVE #8111-1.1-OR, 1.1 GPF AND & BEMIS OPEN FRONT SEAT
#1955SSCT-000. LOCATE HANDLE ON WIDE SIDE OF FIXTURE
NOTES:1. DATA GIVEN IN SCHEDULE PROVIDES CODE REQUIRED FLOW RATES AND MINIMUM BRANCH PIPING SIZES.
2. BRANCH LINE SIZE MINIMUMS ARE TO BE AS SPECIFIED IN THIS CHART UNLESS OTHERWISE NOTED.
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
L
e
a
d
S
h
e
e
t
s
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
ME
C
H
A
N
I
C
A
L
&
P
L
U
M
B
I
N
G
S
C
H
E
D
U
L
E
S
MP-001
DUCTLESS SPLIT SYSTEM HEAT PUMP SCHEDULE
TAG MAKE NOM
TONS
SENSIBLE
COOLING REFRIGERANT
AHRI PERFORMANCE
INDOOR UNIT OUTDOOR UNIT
REMARKS
SEE BELOW
COOLING HEATING
BTUH SEER2 EER2 BTUH AT
47°F
BTUH AT
17°F HSPF2 MODEL INSTALLATION
TYPE
POWER
V/ɸ/HZ MCA MOCP CFM WATTS
>HP@
OPERATING
WEIGHT
LBS
INSTALLATION
DETAIL MODEL POWER
V/ɸ/HZ MCA MOCP
OPERATING
WEIGHT
LBS
INSTALLATION
DETAIL
DAIKIN 1.5 13,700 R-410A 18,000 16.9 11.9 20,000 13,800 7.6 FAQ18TAVJU HIGH WALL 208/1/60 0.5 15 500 43 35 2/MP-002 RZQ18TBVJUA 208/1/60 16.5 20 175 1/MP-002 C1
GENERAL NOTES APPLICABLE TO ALL UNITS:
A. DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR.
B. UNIT SHALL BE CONFIGURED FOR COOLING ONLY.
C. SIZE REFRIGERATION LINES PER THE MANUFACTURERS REQUIREMENTS FOR TOTAL DEVELOPED LINE LENGTH.
D. PROVIDE WITH MANUFACTURERS CONDENSER WALL MOUNTING BRACKET.
CONTROL NOTES:
C1. PROVIDE WITH MANUFACTURERS MODEL BRC1E73 WIRED CONTROLLER.
DS
1
VENTILATION CALCULATION
System
Tag Room Name
Room
Area
(SQFT)
Table 120.1-A Occupancy
Category
Table 120.1-A
Area Outdoor Air
Rate (cfm/sqft)
CFM
Requirement:
120.1(c)3
(E
)
A
C
U
n
i
t
T
h
a
t
S
e
r
v
e
s
t
h
e
F
i
r
s
t
F
l
o
o
r
Bureau Sargeant 107 149 Office Buildings - Office space 0.15 23
Shared Office 126 354 Office Buildings - Office space 0.15 54
Open Office 102 1848 Office Buildings - Office space 0.15 278
North Stair 1F 151 General - Corridors 0.15 23
South Stair 1F 151 General - Corridors 0.15 23
Hall (Adjacent to Stairs)43 General - Corridors 0.15 7
Lobby 100 260 General - Corridors 0.15 39
Hall 114/115 131 General - Corridors 0.15 20
Break Room 121 240 Office Buildings - Breakrooms 0.5 120
Briefing Room 122 806 General - Conference/meeting 0.5 403
Incident Com. 123 125 Office Buildings - Office space 0.15 19
Dispatch 124 86 Office Buildings - Office space 0.15 13
Meeting 125 126 General - Conference/meeting 0.5 63
TOTAL 1085
(E
)
A
C
U
n
i
t
T
h
a
t
S
e
r
v
e
s
t
h
e
S
e
c
o
n
d
f
l
o
o
r
Int Affairs Lieut. 224 266 Office Buildings - Office space 0.15 40
Break Room 207 244 Office Buildings - Breakrooms 0.5 122
BOS. Manager 208 129 Office Buildings - Office space 0.15 20
Public Affairs Manager
205 134 Office Buildings - Office space 0.15 21
Meeting Room 202 133 General - Conference/meeting 0.5 67
North Stair 2F 154 General - Corridors 0.15 24
South Stairs and Hallway
2F 457 General - Corridors 0.15 69
Train/Hiring Manager 208 132 Office Buildings - Office space 0.15 20
Crime Analyst 209 129 Office Buildings - Office space 0.15 20
Conf. 202 679 General - Conference/meeting 0.5 340
Conf. 202 Hall/Flex
Spaces 646 General - Corridors 0.15 97
Break Room 215 262 Office Buildings - Breakrooms 0.5 131
Chief 214C 452 Office Buildings - Office space 0.15 68
Admin 214A 265 Office Buildings - Office space 0.15 40
Dept. Chief 213 155 Office Buildings - Office space 0.15 24
Dept. Chief 211 139 Office Buildings - Office space 0.15 21
TOTAL 1124
NOTES: AFTER COMPLETION OF CONSTRUCTION AND PRIOR TO OCCUPANCY THE OUTSIDE AIR INTAKE AT THE (E) AC
UNITS SHALL BE BALANCED AS FOLLOWS:
FIRST FLOOR AC UNIT: BALANCE OUTSIDE AIR INTAKE TO 1100 CFM
SECOND FLOOR AC UNIT: BALANCE OUTSIDE AIR INTAKE TO 1125 CFM
1
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
L
e
a
d
S
h
e
e
t
s
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
ME
C
H
A
N
I
C
A
L
&
P
L
U
M
B
I
N
G
D
E
T
A
I
L
S
MP-002NTS
RETURN AIR GRILLE INTO PLENUM4
14x12L
DUCT LINER PER
SPECIFICATIONS
24 GAUGE CAN
1/2" GALVANIZED STEEL MESH
SCREEN OVER OPENING
REFER TO DETAIL
3/MP-002 FOR GRILLE
SUPPORT
NTS
DIFFUSER OR GRILLE INSTALLATION (LAY-IN CEILING)3
CEILING GRID
DIFFUSER OR GRILLE
24 GAGE DIFFUSER CAN
DUCT INSULATION PER
SPECIFICATIONS
2" WIDE, 4" LONG 24 GAUGE CLIP
SECURED TO DIFFUSER CAN WITH
#12 TEK SCREW
#12 SLACK SAFETY WIRE AT
DIAGONAL CORNERS WITH (4) TIGHT
TURNS IN 112"
DUCT INSULATION PER
SPECIFICATIONS
CONICAL FITTING WITH BEAD FOR
FLEXIBLE DUCT CONNECTION
FLEXIBLE DUCT 60" MAX LENGTH,
REFER TO DETAIL 5/MP-002 FOR
ATTACHMENT
24 GAGE
DIFFUSER CAN
ATTACH DIFUSER OR GRILLE TO
CAN WITH (8)#12 TEK SCREWS (2)
PER SIDE EQUALLY SPACED
#12 SLACK SAFETY
WIRE REFER TO
ARCHITECTURAL
DETAILS FOR UPPER
CONNECTION
1
1 MIN
MINIMUM 2" LONG COLLAR WITH
BEAD FOR FLEXIBLE DUCT
CONNECTION
ADAPTER TO NECK
SIZE
1-1/2 RADIUS
ELBOW
SIDE DUCT CONNECTION
TOP DUCT CONNECTION
DUCT INSULATION PER
SPECIFICATIONS
TOP DUCT CONNECTION SHALL BE USED WHERE SPACE PERMITS. ONLY
USE SIDE DUCT CONNECTION WHERE VERTICAL CLEARANCE IS LIMITED.
DIFFUSER SUPPORT NOTES ARE APPLICABLE TO BOTH DUCT
CONNECTION CONFIGURATIONS
NTS
HIGH WALL FAN COIL MOUNTING2
MOUNTING BRACKET
SUPPLIED WITH UNIT, MOUNT
TO BLOCKING IN WALL WITH
(9) M8 WOOD SCREWS
MINIMUM 1-1/2" EMBEDMENT
INTO BLOCKING
CONDENSATE DRAIN IF NOT
PUMPED
REFRIGERATION LINES
AND CONDENSATE
DRAIN WHEN PUMPED
STUD (TYP)
4x4 BLOCKING IN WALL
(TYP)
OUTLINE OF FAN COIL
OUTLINE OF FAN COIL
35 LBS MAX
NTS
FLEXIBLE DUCT CONNECTION5
STAINLESS STEEL
WORM GEAR CLAMP
OVER (2) WRAPS OF
UL-181 DUCT TAPE
STEP - 1:
FOLD BACK JACKET AND INSULATION. SLIDE AT LEAST 1" OF CORE OVER DUCT AND PAST
THE BEAD. SEAL CORE TO DUCT WITH AT LEAST (2) WRAPS OF UL-181 LISTED DUCT TAPE.
SECURE CONNECTION WITH A CLAMP PLACED OVER THE CORE AND TAPE PAST THE BEAD.
OUTSIDE JACKET
INSULATION
WIRE HELIX AND LINING
CORE
OUTSIDE JACKET
INSULATION
OUTSIDE JACKET
INSULATION
WIRE HELIX AND LINING
CORE
WIRE HELIX AND LINING
CORE
STEP - 2:
PULL THE INSULATION AND JACKET OVER THE TOP OF THE CORE AND THE CLAMP. TUCK
THE OUTSIDE JACKET UNDER THE INSULATION.
STEP - 3:
INSTALL A CLAMP AROUND THE ENTIRE FLEXIBLE DUCT ASSEMBLY
STAINLESS STEEL
WORM GEAR CLAMP
DUCT
DUCT
DUCT
24" MIN
NTS
ROUND VOLUME DAMPER6
WING NUT
DAMPER REGULATOR SET
10"Ø AND SMALLER: NO.KSR
12"Ø TO 20"Ø: NO.KSR
21"Ø AND LARGER: NO.KS-12
ALL SETS TO BE "QUADRANT" TYPE
HANDLE
DUCT PENETRATIONS SHALL BE
SEALED AIR TIGHT. ALL MODEL
NUMBERS LISTED ARE DURO DYNE.
1/8" CLEARANCE BETWEEN DAMPER
AND DUCT ALL AROUND
ROD CONTINUOUS ON ALL DAMPERS
OVER 10"Ø
DAMPER, OPPOSED BLADE OR SINGLE
LEAF TYPE
OUTSIDE CLOSED END BEARING NO.
SB, SIZE AS REQUIRED
PLAN
ELEVATION
WALL
ESCUTCHEON (TYP.)
'P'- TRAP
HOSE CLAMP (TYP.)
WYE BRANCH TAILPIECE
SINK
NTS
CONDENSATE TO TAIL PIECE DETAIL 7
ALL CONDENSATE PIPING
SHALL BE TYPE L COPPER
AND INSULATED WITH 1/2"
INSULATION
NEOPRENE HOSE SAME SIZE
AS CONDENSATE DRAIN
CONDENSATE DRAIN LINE IN WALL
NTS
HIGH-WALL FANCOIL CONDENSATE DRAIN8
CEILING
HIGH-WALL FANCOIL UNIT
CONDENSATE PUMP WITH INTEGRAL CHECK VALVE,
REFER TO MECHANICAL PLANS
ADAPTOR AS REQUIRED
COPPER FEMALE THREADED ADAPTOR
WALL
HE
I
G
H
T
S
H
A
L
L
N
O
T
E
X
C
E
E
D
HE
A
D
C
A
P
A
B
I
L
I
T
Y
O
F
P
U
M
P
12
"
M
I
N
CONNECT TO TOP OF GRAVITY
DRAINED CONDENSATE PIPE (TYP)
SLOPE TO DRAIN, REFER TO PLANS FOR SIZE
WALL PENETRATION BEHIND FANCOIL UNIT,
DO NOT RUN PIPING EXPOSED
PROVIDE OPEN VENT ON UPPERMOST
UNIT IN ACCESSIBLE LOCATION
ALL CONDENSATE PIPING
SHALL BE TYPE L COPPER
AND INSULATED WITH 1/2"
INSULATION
NTS
CONDENSING UNIT - WALL MOUNTING BRACKET1
CONDENSER
3'' MIN.(E) CMU
PARAPET WALL
1/4" DIA. 'TITEN
HD SS' ANCHOR,
MIN 2-1/2"
EMBEDMENT
(TYP OF 2 EACH
BRACKET)
(MAX WEIGHT
175 LBS)
40" MAX
4" MIN
12" MIN
8" MIN VERIFY IN FIELD
EPDM GASKET
1/2" ROUND,
3/32" THICK,
FLAT SS
WASHER
MOUNTING LEG
INTEGRAL TO
CONDENSING UNIT
MOUNTING BRACKET
(TYP OF 2)
FASTEN
CONDENSER WITH
HARDWARE
PROVIDED WITH
MOUNTING BRACKET
(E) SINGLE PLY
ROOFING
(E) SINGLE PLY
ROOF SURFACE
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
L
e
a
d
S
h
e
e
t
s
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
EN
E
R
G
Y
C
O
M
P
L
I
A
N
C
E
D
O
C
U
M
E
N
T
A
T
I
O
N
EC-000
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
(E)18Ø
(E)14Ø
(E)14Ø
(E)S (E)S (E)S
(E)S
POD(E)R (E)R (E)R
(E)R
1 1 1
1 1 1
1
2
3
4
(E)E150
(E)E150
(E)S100
(E)S100
1
1
1
1
7
7
7
7
(E)R 1
5
6 5
1 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN
SCALE:1/8" = 1'-0"
DEMOLITION KEY NOTES
APPLICABLE TO THIS SHEET ONLY
GRILLE/DIFFUSER TO BE REMOVED AND DISCARDED.
REMOVE ALL DUCTWORK UPSTREAM OF POD.
(E) LAV TO BE REMOVED. PIPING TO REMAIN.
(E) URINAL TO BE REMOVED. CAP PIPING IN WALL.
(E) FIXTURE TO BE REMOVED. PIPING TO REMAIN.
REMOVE (E) STAND PIPE AND ASSOCIATED STOPS. CAP PIPING UNDER
CABINET.
DISCONNECT DUCT FROM GRILLE/DIFFUSER. CAP DUCT TO KEEP CLEAN
UNTIL RECONNECTION TO NEW GRILLE/DIFFUSER.
1
2
3
4
5
6
7
DEMOLITION PLAN STATEMENT
THIS DEMOLITION PLAN WAS PREPARED FOR THE CONVENIENCE OF THE
CONTRACTOR. THE ENGINEER DOES NOT REPRESENT THAT ALL ITEMS WHICH
MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND
THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND
RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK. DISPOSE OF ALL EQUIPMENT PER THE OWNER'S
DIRECTION WHILE COMPLYING WITH ALL LOCAL CODES AND ORDINANCES.
ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE
BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS
MAY NOT BE ACCURATE.
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
P
l
a
n
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
ME
C
H
A
N
I
C
A
L
&
P
L
U
M
B
I
N
G
D
E
M
O
L
I
T
I
O
N
F
I
R
S
T
F
L
O
O
R
P
L
A
N
MPD-101
T
(E)S650 (E)S650
(E)S 325 (E)S250
(E)18Ø
(E)14Ø
(E)18Ø
(E)S100
(E)10Ø
(E)6Ø
(E)10Ø
(E)10Ø
(E)14Ø
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
POD
POD
(E)R
POD
(E)R
1
2
1 1
1
2
1
3
(E)R
(E)E200
(E)S 150
(E)S200
(E)R
(E)E250
1
1
1
1
1
1
4
4
4
4
5
6
6
6
6
6
6
6
6
1 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN
SCALE:1/8" = 1'-0"
DEMOLITION KEY NOTES
APPLICABLE TO THIS SHEET ONLY
GRILLE/DIFFUSER TO BE REMOVED AND DISCARDED.
REMOVE ALL DUCTWORK UPSTREAM OF POD.
(E)FIXTURE TO BE REMOVED. CAP PIPING IN WALL AND BELOW FLOOR.
DISCONNECT DUCT FROM GRILLE/DIFFUSER. CAP DUCT TO KEEP CLEAN
UNTIL RECONNECTION TO NEW GRILLE/DIFFUSER
(E)EXHAUST FAN TO BE REMOVED. DISCONNECT FROM POWER AND
DUCTWORK. CAP DUCT AIR TIGHT.
(E) FIXTURE TO BE REMOVED. PIPING TO REMAIN.
1
2
3
4
5
6
DEMOLITION PLAN STATEMENT
THIS DEMOLITION PLAN WAS PREPARED FOR THE CONVENIENCE OF THE
CONTRACTOR. THE ENGINEER DOES NOT REPRESENT THAT ALL ITEMS WHICH
MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND
THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND
RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK. DISPOSE OF ALL EQUIPMENT PER THE OWNER'S
DIRECTION WHILE COMPLYING WITH ALL LOCAL CODES AND ORDINANCES.
ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE
BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS
MAY NOT BE ACCURATE.
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
P
l
a
n
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
ME
C
H
A
N
I
C
A
L
&
P
L
U
M
B
I
N
G
D
E
M
O
L
I
T
I
O
N
S
E
C
O
N
D
F
L
O
O
R
P
L
A
N
MPD-102
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
MEETING
125
DISPATCH
124
LOBBY
100
STORAGE
111
SHARED
OFFICE
126
BUREAU
SERGEANT
107
DETECTIVE
EQUIPMENT
106
DRONE/EQUIP
STORAGE
105OPEN OFFICE
102
MEN
118
JAN.
117
HALL
115
WOMEN
119
BREAK
ROOM
121
ELECTRICAL
120
INCIDENT
COM.
123
BRIEFING
ROOM
122
ELEVATOR
127
(E)18Ø
(E)14Ø
POC
(E)R
S1 450
15x15S1450
15x15 (E)S 600
12Ø 14Ø
12Ø
(E)14Ø
R1 22x22
HALL
114
STORAGE
STAIR
HALL
139
DF-12
E1150
12x12
E1150
12x12
S1100
6x6
S1100
6x6
3
3
3
3
STAIR
123
TYPICAL VOLUME
DAMPER, REFER TO
DETAIL 6/MP-002
R1 22x22
R122x22
LAV-1
WC-1
WC-1
LAV-1
1 MECHANICAL & PLUMBING FIRST FLOOR PLAN
SCALE:1/8" = 1'-0"
KEY NOTES
APPLICABLE TO THIS SHEET ONLY
CONNECT NEW FIXTURE WITH EXISTING PIPING IN WALL. 1/2" HOT AND COLD
WATER, 1-1/2" VENT AND 2" WASTE.
CONNECT NEW FIXTURE WITH EXISTING PIPING IN WALL. 1/2" COLD WATER,
1-1/2" VENT AND 2" WASTE.
CONNECT (E) DUCT TO NEW GRILLE/DIFFUSER.
GENERAL NOTES
APPLICABLE TO THIS SHEET ONLY
1
ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM
THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING
ITEMS MAY NOT BE ACCURATE.
2
NEW FLEXIBLE DUCT SHALL NOT EXCEED 60" IN LENGTH. EXTEND EXISTING
RIGID DUCT AS NECESSARY TO MAKE THE FLEXIBLE DUCT CONNECTION TO
THE DIFFUSER NO MORE THAN 60" LONG.
3 SEE PLUMBING FIXTURE SCHEDULE FOR BRANCH PIPE SIZING.
4 PROVIDE ANGLE STOPS FOR ALL PLUMBING FIXTURE BRANCH PIPING LINES.
5
REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF FIXTURES,
INCLUDING BUT NOT LIMITED TO FLOOR SINKS, FLOOR DRAINS, TRENCH
DRAINS, ROOF DRAINS, ETC.
6 AFTER COMPLETION OF THE DUCTWORK MODIFICATIONS, BALANCE THE
SHOWN AIR DISTRIBUTION TO THE VALUES LISTED.
1
2
3
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
P
l
a
n
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
ME
C
H
A
N
I
C
A
L
&
P
L
U
M
B
I
N
G
F
I
R
S
T
F
L
O
O
R
P
L
A
N
MP-200
UP
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
BREAK
ROOM
215
SERVER
216
PANTRY
216
CHIEF
214C
ADMIN
214A
DEPT.
CHIEF
213
DEPT.
CHIEF
211
COPY
ROOM
210
ELEV MECH
112
ELEVATOR
131
CONF.
202
MEETING
ROOM
202
PUBLIC
AFFAIRS MANAGER
205
BOS.
MANAGER
206
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
JAN
223
WOMENS
222
HALL
149
EQUIP.
220
TRAIN/HIRING
MANAGER
208
CRIME
ANALYST
209
T
S1600
15x15
(E)S250
(E)18Ø
(E)14Ø
(E)18Ø
(E)S100
(E)10Ø
(E)6Ø
(E)10Ø
(E)10Ø
(E)14Ø
POC
14Ø
S1625
15x15
S1 400
15x15
POC
POC
R1 22x22
R1 22x22
WC-21
STAIRS
144
T
2DS
1
ODU ON
ROOF
DS
1
IDU
ON WALL ABOVE DOOR
E1200
12x12
S1 150
9x9
S1200
9x9
E1250
12x12
3
3
3
3
REFRIGERANT
PIPING DN FRM
ROOF
WC-1
LAV-1
WC-1
WC-2
WC-2
LAV-1
LAV-1
DS-1
IMS-1
S-1
1/2"CW DOWN
IN WALL
4
UR-1
STAIRS
152
6
POC
1 MECHANICAL & PLUMBING SECOND FLOOR PLAN
SCALE:1/8" = 1'-0"
KEY NOTES
APPLICABLE TO THIS SHEET ONLY
CONNECT NEW FIXTURE WITH EXISTING PIPING. 3/4" COLD WATER, 2" VENT
AND 3" WASTE.
3/4" CD DN SERVER ROOM WALL. CONNECT TO SINK TAILPIECE PER DETAIL
7/MP-002.
CONNECT (E) DUCT TO NEW GRILLE/DIFFUSER.
CONNECT 1/2"CW TO (E) CW. PLUMBER TO FIELD VERIFY EXACT LOCATION
OF PIPING.
3/4" CONDENSATE CONNECTION TO MECHANICAL EQUIPMENT. SEE DETAIL
8/MP-002 FOR MORE INFORMATION.
SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION.
GENERAL NOTES
APPLICABLE TO THIS SHEET ONLY
1
ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM
THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING
ITEMS MAY NOT BE ACCURATE.
2
NEW FLEXIBLE DUCT SHALL NOT EXCEED 60" IN LENGTH. EXTEND EXISTING
RIGID DUCT AS NECESSARY TO MAKE THE FLEXIBLE DUCT CONNECTION TO
THE DIFFUSER NO MORE THAN 60" LONG.
3 SEE PLUMBING FIXTURE SCHEDULE FOR BRANCH PIPE SIZING.
4 PROVIDE ANGLE STOPS FOR ALL PLUMBING FIXTURE BRANCH PIPING LINES.
5
REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF FIXTURES,
INCLUDING BUT NOT LIMITED TO FLOOR SINKS, FLOOR DRAINS, TRENCH
DRAINS, ROOF DRAINS, ETC.
6 AFTER COMPLETION OF THE DUCTWORK MODIFICATIONS, BALANCE THE
SHOWN AIR DISTRIBUTION TO THE VALUES LISTED.
1
2
3
4
5
6
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
S:
\
S
h
a
r
e
d
\
J
o
b
s
\
E
N
G
P
r
o
j
e
c
t
s
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
\
E
n
g
i
n
e
e
r
i
n
g
\
S
L
O
P
D
N
o
r
t
h
B
u
i
l
d
i
n
g
T
I
M
e
c
h
a
n
i
c
a
l
a
n
d
P
l
u
m
b
i
n
g
P
l
a
n
.
d
w
g
k
h
a
n
j
i
e
v
S
e
p
1
3
,
2
0
2
4
-
9
:
5
7
a
m
AS INDICATED
05/14/2024
2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW
COPYRIGHT AND OTHER PROPERTY RIGHTS
RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL
NOT BE DUPLICATED, COPIED, DISCLOSED OR USED
IN CONNECTION WITH ANY WORK OR PROJECT
OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT
HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED
TO ANY THIRD PARTY WITHOUT FIRST OBTAINING
THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE
CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.
R
E
G
I
STE R E D P R O F E S S I ON
A
L
E
N
G
I
N
E
E
R
B R I A N P.S TA
RR
E
T
T
S
T
A
TE
OF C A L I F O R N I
AM
ECH A N I C A L
EXP. 6/30/26
M 34068
DS
KH
BS
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
ME
C
H
A
N
I
C
A
L
&
P
L
U
M
B
I
N
G
S
E
C
O
N
D
F
L
O
O
R
P
L
A
N
MP-300
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
1
p
m
-
C
h
r
i
s
-
C
:
\
U
s
e
r
s
\
c
h
r
i
s
\
a
p
p
d
a
t
a
\
l
o
c
a
l
\
t
e
m
p
\
A
c
P
u
b
l
i
s
h
_
2
7
7
0
4
\
2
4
-
8
0
2
6
_
E
-
0
0
1
-
E
L
E
C
T
R
I
C
A
L
G
E
N
E
R
A
L
N
O
T
E
S
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1.CODE COMPLIANCE: ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH CODES,
STANDARDS, AND ORDINANCES AS SET FORTH BY THE AUTHORITIES HAVING JURISDICTION AND THEIR
LATEST ADOPTED EDITIONS (IN EFFECT AT TIME OF BUILDING PERMIT APPLICATION) OF THE FOLLOWING
PUBLICATIONS:
A.ALL WORK SHALL COMPLY WITH 2020 NATIONAL ELECTRICAL CODE (NEC) AS AMENDED BY THE 2022
CALIFORNIA ELECTRICAL CODE (CEC), 2022CALIFORNIA BUILDING CODE (CBC), 2022 CALIFORNIA
ENERGY CODE (CEnC), CALIFORNIA FIRE CODE (CFC), 2022 CALIFORNIA MECHANICAL CODE (CMC),
2022 CALIFORNIA GREEN BUILDING STANDARDS (CGBC), AND ADOPTED ORDINANCES.
B.AMERICANS WITH DISABILITIES ACT (ADA).
2.SAFETY: THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN A SAFE AND
RESPONSIBLE MANNER. KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED.
CONDUCT ALL CONSTRUCTION OPERATIONS IN A SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER
WORKPERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS, FLAGS, TAPE, ETC. AS
REQUIRED FOR SAFETY. THE CONTRACTOR SHALL HOLD ALL PARTIES HARMLESS OF NEGLIGENT SAFETY
PRACTICES, WHICH MAY CAUSE INJURY TO OTHERS ON OR NEAR THE JOB SITE.
3.FIRE RATED ASSEMBLIES SHALL MAINTAIN RATINGS AS SPECIFIED IN THE CALIFORNIA BUILDING CODE
CHAPTER 7. CONTRACTOR SHALL PROVIDE AND INSTALL PHYSICAL ENCLOSURE AROUND FIXTURES,
PANELS, ETC. AS REQUIRED. ALL ASSEMBLIES TO BE PENETRATED SHALL BE INSTALLED WITH
APPLICABLE THROUGH-PENETRATION FIRESTOP SYSTEM AS DETERMINED BY UL CLASSIFICATION.
BEFORE CONSTRUCTION, VERIFY AND COMPLY WITH REQUIREMENTS OF LOCAL AUTHORITY HAVING
JURISDICTION.
4.MOUNTING HEIGHTS SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED:
+15" AFF: RECEPTACLES, TELEPHONE, TV & DATA OUTLETS. (MEASURED BOTTOM OF OUTLET BOX)
+46" AFF: OUTLET ABOVE COUNTER (MEAUSRED TOP OF OUTLET BOX)
+48" AFF: LIGHT SWITCHES. (MEASURED TOP OF OUTLET BOX)
+48" AFF: FIRE ALARM MANUAL PULL STATIONS, T-STATS. (MEASURED TOP OF OUTLET BOX)
THE LOWER OF +80" AFF TO BOTTOM OF LENS, OR 6" BELOW CEILING: FIRE ALARM VISUALS.
ELECTRICAL SWITCHES: CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE
ROOM OR AREA TO CONTROL LIGHT AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING
AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP
OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO
THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. [CBC 11B-308.1.1]
ELECTRICAL RECEPTACLE OUTLETS: ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30
AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48
INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR
LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR
RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM [CBC 11B-308.1.2]
CONTROLS AND OPERATING MECHANISMS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION
11B-309.
BEFORE ROUGH-IN, VERIFY ALL MOUNTING HEIGHTS AND EXACT LOCATIONS FOR ALL EQUIPMENT
ELECTRICAL CONNECTIONS, STUB-UPS, RECEPTACLES, OUTLETS, ETC. WITH ARCHITECT OR OWNER.
PLACE DEVICES LOCATED ABOVE COUNTERS, SHELVING, ETC. AND IN BATHROOMS SO AS NOT TO
CONFLICT WITH EDGES OF WAINSCOTING, COUNTER SPLASH, SHELVING, ETC. ARCHITECTURAL SHEETS
SHALL GOVERN.
5.LABEL PANELS, CABINETS, BACKBOARDS, MAIN DEVICES, SAFETY SWITCHES, CONTACTORS AND OTHER
SPECIFICALLY DESIGNATED EQUIPMENT SHOWN ON PLANS. USE ENGRAVED LAMINATED PLASTIC
NAMEPLATES ATTACHED BY SCREWS OR RIVETS. FOR FEEDERS, NEATLY AND INDELIBLY LABEL CONDUIT
DESTINATIONS ON BOTH VISIBLE ENDS OF CONDUIT RUNS WHERE CONDUITS TERMINATE AT DESIGNATED
ENCLOSURES, STRUCTURES OR EQUIPMENT (INCLUDING PULL AND SPLICE BOXES).
5.EQUIPMENT ANCHORAGE NOTE
ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED TO MEET THE
HORIZONTAL AND VERTICAL FORCES PRESCRIBED IN THE 2022 CBC, SECTIONS 1617A.1.18 THROUGH
1617A.1.26, AND ASCE 7-15 CHAPTERS 13, 26, AND 30 AND 2022 CEC 110.3(B)
THE ATTACHMENT OF THE FOLLOWING ITEMS SHALL BE DESIGNED TO RESIST THE FORCES PRESCRIBED
ABOVE, BUT NEED NOT BE DETAILED ON THE PLANS PER 2022 CBC SECTION 1616A.1.18:
A.FURNITURE(EXCEPT STORAGE CABINETS AS NOTED IN 2022 CBC TABLE 13.5-1)
B.TEMPORARY OR MOVABLE EQUIPMENT WITH EXCEPTIONS NOTED IN 2022 CBC SECTION 1616A.1.18
ITEM 2.
C.ARCHITECTURAL, MECHANICAL, AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D,
E, OR F
THAT MEET ALL OF THE CRITERIA LISTED IN 2022 SECTION 1616A.1.18 ITEM 3.
D.EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUPPORTED BY VIBRATION ISOLATORS.
E.EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM
A
WALL
FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION
SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL/ELECTRICAL ENGINEER.
PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTE
PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE
FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-16, SECTION 13.3 AS DEFINE IN ASCE 7-16 SECTIONS
13.6.5, 13.6.6, 13.6.7, 13.6.8, AND 2022 CBC, SECTIONS 1617A.1.24, 1617A.1.25, AND 1617A.1.26.
6.THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING
THE CORRECTION OF ERROS ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE
CODES ADOPTED BY THE CITY, RELEVANT LAWS, ORDINANCES, RULES AND/OR REGULATIONS.
GENERAL NOTES
DEMOLITION FLOOR PLAN
A.FUSING: ALL FUSIBLE SAFETY DISCONNECT SWITCHES SHALL BE PROVIDED WITH DUAL-ELEMENT TIME
DELAY TYPE FUSES SIZED AND RATED PER EQUIPMENT MANUFACTURERS' RECOMMENDATIONS. VERIFY
WITH EQUIPMENT NAMEPLATE BEFORE INSTALLATION.
B.INSTALL SEPARATE NEUTRALS FOR EACH 120V BRANCH CIRCUIT.
C.MOTOR OVERLOAD PROTECTION: WHERE REQUIRED BY NEC ARTICLE 430 PART C AND NOT SHOWN ON PLAN
OR PROVIDED INTEGRAL WITH EQUIPMENT, PROVIDE AND INSTALL THERMAL OVERLOAD PROTECTION FOR
ALL MOTORS.
D.SPARE CONDUIT FOR RECESSED PANELS: PROVIDE (1) 3/4" SPARE CONDUIT STUB UP TO ACCESSIBLE ABOVE
CEILING SPACE AND/OR ACCESSIBLE SPACE BELOW FOR EVERY (3) SPARE BREAKER SPACES AS INDICATED
ON PANEL SCHEDULES.
E.DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD
VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE,
ETC. AND SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER EQUIPMENT.
F.ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION, SHALL BE MOUNTED ON
OPPOSITE SIDES OF THE SAME STUD. COORDINATE BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS.
G.ALL NEW OUTLETS MUST BE TAMPER PROOF.
H.ALL 15 AND 20AMPERE RECEPTACLES FOR BOTH DAMP AND WET LOCATIONS REQUIRED TO BE LISTED
WEATHER-RESISTANT (WR) TYPE PER CEC 406.9 (A) AND (B)
I.CEC 406.9(A) RECEPTACLES IN DAMP LOCATIONS: RECEPTACLES INSTALLED OUTDOORS IN A LOCATION
PROTECTED FROM THE WEATHER OR IN OTHER DAMP LOCATIONS SHALL BE AN ENCLOSURE FOR THE
RECEPTACLE THAT IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT PLUG CAP NOT
INSERTED AND RECEPTACLE COVERS CLOSE)
J.CEC 406.9(B) RECEPTACLES OF 15 AND 20AMP, 125 AND 250 VOLTS INSTALLED IN A WET LOCATION SHALL
HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS
INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BE
IDENTIFIED AS 'EXTRA-DUTY" OTHER LISTED PRODUCTS, ENCLOSURES, OR ASSEMBLIES PROVIDING
WEATHERPROOF PROTECTION THAT DO NOT UTILIZE AN OUTLET BOX HOOD NEED TO BE MARKED "EXTRA
DUTY"
EXCEPTION: 15 AND 20AMP, 125 THROUGH 250 VOLT RECEPTACLES INSTALLED IN A WET LOCATION AND
SUBJECT TO ROUTINE HIGH-PRESSURE SPRAY WASHING SHALL BE PERMITTED TO HAVE AN ENCLOSURE
THAT IS WEATHERPROOF WHEN THE ATTACHMENT PLUG IS REMOVED.
A.NIGHT LIGHT "NL" DESIGNATED LUMINAIRES IN INTERIOR LOCATIONS SHALL HAVE ONE BALLAST
CONTINUOUSLY ENERGIZED. LUMINAIRES IN EXTERIOR LOCATIONS SHALL BE AUTOMATICALLY CONTROLLED
TO BE ON FROM DUSK TO DAWN.
B.LIGHTING FIXTURE LOCATIONS SHOWN ARE SCHEMATIC. REFER TO ARCHITECTURAL PLANS (REFLECTED
CEILING, ELEVATIONS, ETC.) FOR EXACT LOCATIONS AND MOUNTING HEIGHTS PRIOR TO ROUGH-IN.
C.REFER TO ARCHITECT'S REFLECTED CEILING PLAN(S) FOR CEILING HEIGHTS, TYPES, FINISHES, ETC. IN EACH
AREA. VERIFY FLANGE TYPES, TRIM KITS, STEM LENGTHS, ETC. FOR ALL FIXTURES PRIOR TO SUBMITTALS.
D.CONFIRM LOCATION OF ALL DOORS SWINGS WITH ARCHITECTURAL PLANS PRIOR TO ROUGH-IN OF
SWITCHES.
E.PROVIDE UNSWITCHED HOT LEG OF ROOM LIGHTING BRANCH CIRCUIT TO EACH BATTERY POWERED
EMERGENCY LIGHT AND EXIT SIGN FOR CONTINUOUS CHARGING.
LIGHTING FLOOR PLAN
RATED WALLS/ASSEMBLIES NOTES
SHEET NO.SHEET DESCRIPTION
E-001 ELECTRICAL GENERAL NOTES
E-002 ELECTRICAL LEGEND AND ABBREVIATIONS
E-003 ELECTRICAL SINGLE LINE DIAGRAM AND SCHEDULES
ED-101 FIRST FLOOR POWER AND SIGNAL DEMOLITION PLAN
ED-102 SECOND FLOOR POWER AND SIGNAL DEMOLITION PLAN
E-101 FIRST FLOOR POWER AND SIGNAL PLAN
E-102 SECOND FLOOR POWER AND SIGNAL PLAN
E-111 FIRST FLOOR LIGHTING PLANS
E-112 SECOND FLOOR LIGHTING PLANS
E-113 LIGHTING EMERGENCY PHOTOMETRIC PLANS
E-121 ELECTRICAL ROOF PLAN
E-201 ELECTRICAL DETAILS
E-301 TITLE 24 ENERGY FORMS - INTERIOR LIGHTING
ELECTRICAL SHEET INDEX
POWER FLOOR PLAN
1.IN FIRE-RESISTANCE RATED WALLS, DETAIL THROUGH PENETRATIONS AND MEMBRANE PENETRATION PER
CBC 714.4 AS NOTED BELOW:
A.STEEL, FERROUS OR COPPER PIPES MAY PENETRATE FIRE-RESISTANCE RATED WALLS, PROVIDED
THE OPENING IS PROTECTED AS FOLLOWS: (CBC 714.4.1)
i. ITEM PENETRATING CONCRETE OR MASONRY WALLS IS A MAXIMUM 6 INCHES NOMINAL DIAMETER
AND THE AREA OF THE OPENING THROUGH THE WALL DOES NOT EXCEED 144 SQUARE INCHES,
CONCRETE, GROUT OR MORTAR IS PERMITTED WHERE IT IS INSTALLED THE FULL THICKNESS OF
THE WALL OR THE THICKNESS REQUIRED TO MAINTAIN THE F IRE-RESISTANCE RATING; OR
ii. WHEN THE ANNULAR SPACE IS PROTECTED WITH MATERIAL THAT MEETS ASTM E 119 OR UL
263.
B. PENETRATIONS SHALL BE FIRE-STOPPED BY A SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479, AND SHALL HAVE AN F RATING OF NOT LESS THAN THE REQUIRED
FIRE-RESISTANCE RATING OF THE WALL PENETRATED. (CBC 714.4.1.2)
C.MEMBRANE PENETRATIONS OF MAXIMUM 2-HOUR FIRE-RESISTANCE RATED WALLS BY STEEL
ELECTRICAL BOXES ARE PERMITTED, PROVIDED THAT EACH DOES NOT ESCEED 16 SQUARE INCHES
IN AREA AND THE TOTAL AREA OF SUCH OPENING DOES NOT EXCEED 100 SQUARE INCHES FOR ANY
100 SQUARE FEET OF WALL AREA, AND THE SPACE BETWEEN THE WALL MEMBRANE AND THE BOX
DOES NOT EXCEED 1
8 INCH. ADDITIONALLY, OUTLET BOXES ON OPPOSITE SIDES OF THE WALL SHALL
BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES (CBC 714.4.2 EXCEPTION
1).
D.MEMBRANE PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY MATERIAL ARE PERMITTED,
PROVIDED SUCH BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE RATED ASSEMBLIES, AND
THE SPACE BETWEEN THE WALL MEMBRANE AND THE BOX DOES NOT EXCEED 1/8 INCH UNLESS
LISTED OTHERWISE. ADDITIONALLY, OUTLET BOXES ON OPPOSED SIDES OF THE WALL SHALL BE
SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES. (CBC 714.4.2 EXCEPTION 2)
E.A FIRE SPRINKLER SHALL BE PERMITTED TO BE UNPROTECTED PROVIDED SUCH SPACE IS COVERED
BY A METAL ESCUTCHEON PLATE. (CBC 714.4.2 EXCEPTION 5)
F.WHERE WALLS ARE PENETRATED BY OTHER MATERIALS OR OPENINGS LARGER THAN THOSE
MENTIONED ABOVE, THEY MUST BE QUALIFIED BY TEST IN ACCORDANCE WITH CBC 714.4.2
EXCEPTION 2.
2.IN FIRE-RESISTANCE HORIZONTAL ASSEMBLIES , DETAIL THROUGH PENETRATIONS AND MEMBRANE
PENETRATION PER CBC 714.5 AS NOTED BELOW:
A.STEEL, FERROUS OR COPPER CONDUITS MAY PENETRATE FIRE-RESISTANCE RATED FLOOR
ASSEMBLY WHEN THE ANNULAR SPACE IS PROTECTED WITH MATERIAL THAT MEETS ASTM E 119 OR
UL 263 (CBC 714.5.1 EXCEPTION 1)
B.PENETRATING ITEMS, AS NOTED ABOVE, WITH A MAXIMUM 6 INCHES NOMINAL DIAMETER SHALL NOT
BE LIMITED TO THE PENETRATION OF A SINGLE FIRE-RESISTANCE RATED FLOOR ASSEMBLY,
PROVIDED THAT THE AREA OF THE OPENINGS DOES NOT EXCEED 144 SQUARE INCHES IN ANY 100
SQUARE FEET OF FLOOR AREA. (CBC 714.4.1.1 EXCEPTION 1)
C.PENETRATIONS SHALL BE FIRE-STOPPED BY A SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH
ASTM E 814 OR UL 1479. THE SYSTEM SHALL HAVE AN F RATING AND T RATING OF NOT LESS THAN
1-HOUR BUT NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE FLOOR PENETRATED
(CBC 714.5.1)
D.MEMBRANE PENETRATIONS BY LISTED ELECTRICAL OUTLET BOXES ARE PERMITTED PROVIDED SUCH
BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE RATED ASSEMBLIES, AND THE SPACE
BETWEEN THE CEILING MEMBRANE AND THE BOX DOES NOT EXCEED 1/8 INCHESUNLESS LISTED
OTHERWISE. (CBC 714.5.2 EXCEPTION 4)
E.A FIRE SPRINKLER SHALL BE PERMITTED TO BE UNPROTECTED PROVIDED SUCH SPACE IS COVERED
BY A METAL ESCUTCHEON PLATE. (CBC 714.5.2 EXCEPTION 5)
3.JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE RATED WALL, FLOOR OR FLOOR/CEILING ASSEMBLIES
AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED AN APPROVED FIRE-RESISTANT JOINT
SYSTEM WITH A FIRE-RESISTANCE RATING NOT LESS THAN THAT OF THE ASSEMBLY IN WHICH IT IS
INSTALLED. PROVIDE DETAILS (CBC 7145.1)
4.FIRE DOORS AND FIRE-PROTECTION RATED GLAZING SHALL BEAR LABELS AS REQURIED BY CBC
716.2.9 AND 716.3.5.
5.FIRE DAMPERS SHALL BE THE MINIMUM FIRE PROTECTION RATING SPECIFIED IN CBC TABLE 717.3.2.1
FOR THE TYPE OF PENETRATION (CBC 717.3.2.1)
6.PROVIDE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION
DAMPERS SHALL BE PROVIDE AS PRESCRIBED IN CBC 717.
REFER TO SPECIFICATIONS 26 0519 FOR ADDITIONAL INFORMATION.
1. WIRE CONNECTORS SHALL BE MINIMUM 75 DEGREE CENTIGRADE RATED AND PROPERLY SIZED FOR THE
NUMBER OF CONDUCTORS BEING CONNECTED, TERMINATED, SPLICED, ETC. ALL ABOVE GRADE
CONNECTORS SHALL BE SOLDERLESS LUG OR PLASTIC WIRE NUT TYPE, SCREW ON, PRESSURE CABLE TYPE
(WIRE UT OR SPRING NUT TYPE) 600 VOLT, 105 DEGREE C, WITH SKIRT TO COVER ALL PORTIONS OF
STRIPPED WIRES. CONNECTOR SHALL BE U.L. RATED FOR NUMBER AND SIZE OF CONDUCTORS BEING
JOINED TOGETHER AS SPLICED.
2. WIRES AND CABLES FOR LINE VOLTAGE SYSTEM AND CONTROLS. WIRE AND CABLE SHALL BE COPPER, 600
VOLT RATED THROUGH OUT. CONDUCTORS 14AWG OT 10AWG, SOLID OR STRANDED. CONDUCTORS 8 AWG
AND LARGER, STRANDED
3. ALL CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE NOTED. MINIMUM SIZE FOR INDIVIDUAL
CONDUCTORS SHALL BE #12 AWG UNLESS OTHERWISE NOTED ON PANEL SCHEDULE OR PLANS. SIZE #8 AWG
AND LARGER SHALL BE STRANDED CONDUCTOR. INDIVIDUAL CONDUCTORS SHALL BE INSULATED WITH
TYPE, XHHW, THW, THHN/THWN 600 VOLT INSULATION UNLESS OTHERWISE NOTED.
4. PROPER INSULATION TYPE SHALL BE USED FOR THE PROPER ENVIRONMENTAL APPLICATION (I.E.
WATERPROOF, WET LOCATION, PLENUM TEMPERATURE RATED). ALL CONDUCTORS, WIRING CABLE WHERE
INSTALLED BELOW FLOOR, SLAB OR UNDERGROUND SHALL BE CONSIDERED WET LOCATIONS, AND SHALL BE
RATED ACCORDINGLY. NON WATERPROOF CABLING IS NOT ALLOWED IN ANY BELOW GRADE OR WET
APPLICATION.
5.GROUP THE COMMON NEUTRAL CONDUCTOR FOR MULTIPLE CIRCUITS WITH ITS ASSOCIATED UNGROUNDED
CONDUCTORS WHEN CONTAINED IN THE SAME ENCLOSURE. CEC 200.4(B)
6.THE BRANCH CIRCUIT SERVING EMERGENCY LIGHTING AND POWER CIRCUITS SHALL NOT BE PART OF A
MULTIWIRE BRANCH CIRCUIT. CEC 700.19.
CONDUCTORS AND CABLES
COMMUNICATIONS PLAN NOTES
A.PROVIDE SEALTITE POWER & CONTROL CONNECTIONS TO ALL AC UNITS.
B.ALL EQUIPMENT SHOWN ABOVE ROOF IS NEMA 3R.
C.VERIFY EXACT EQUIPMENT LOCATIONS AND POINTS OF CONNECTION WITH MECHANICAL CONTRACTOR
PRIOR TO ROUGH-IN.
D.CONDUIT SHOWN IS ROUTED IN CEILING SPACE BELOW ROOF DECK.
E.NO ROOF MOUNT CONDUIT IS ALLOWED UNLESS OTHERWISE NOTED.
F.FUSE DISCONNECT SWITCHES PER EQUIPMENT NAMEPLATE RATING.
G.ALL ROOF PENETRATIONS SHALL BE MADE WITH ROOF JACKS, SEAL ALL PENETRATIONS WITH MASTIC.
ROOF PLAN NOTES
A. REFER TO ARCHITECTURAL DEMOLITION SHEETS FOR ADDITIONAL INFORMATION.
B. EQUIPMENT SHOWN TO BE REMOVED IS SHOWN FOR REFERENCE ONLY. INFORMATION WAS OBTAINED
FROM ORIGINAL BUILDING DRAWINGS AND LIMITED FIELD INVESTIGATION AND MAY NOT REPRESENT ALL
ELECTRICAL DEMOLITION. FIELD VERIFY CONDITIONS AND DISCONNECT/REMOVE ALL EQUIPMENT AS
REQUIRED TO MEET THE INTENT OF THAT SHOWN ON THE LIGHTING AND POWER/SIGNAL DRAWINGS.
C. ALL ELECTRICAL EQUIPMENT SHOWN ON DRAWING (OR REQUIRED) TO BE DEMOLISHED SHALL BE
DISCONNECTED, REMOVED AND DISPOSED OF BY ELECTRICAL CONTRACTOR. NO EQUIPMENT (RACEWAYS,
BOXES, CABLING, ETC.) SHALL BE ABANDONED IN PLACE AND COVERED BY NEW CONSTRUCTION.
D. CLEAN, REPAIR (AS REQUIRED) AND RELAMP ALL EXISTING LIGHT FIXTURES THAT ARE TO REMAIN AND BE
RE-USED TO ASSUME ALL FIXTURE ARE OPERATIONAL UPON COMPLETION OF PROJECT.
E. ANY LIGHT SWITCHES THAT ARE NO LONGER IN USE, WHETHER SHOWN ON THE DEMOLITION PLAN OR NOT,
ARE TO HAVE THE DEVICE AND WIRING REMOVED, AND A BLANK COVER PLATE INSTALLED.
F. SCHEDULE ANY OUTAGES WITH OWNER PRIOR TO DE-ENERGIZATION OF ANY BRANCH CIRCUITS OR
FEEDERS.
G. DISCONNECTION/REMOVAL OF EXISTING COMMUNICATIONS SYSTEMS COMPONENTS SHALL BE SCHEDULED
WITH CITY OF SAN LUIS OBISPO.
H. SALVAGE ALL REMOVED COMPONENTS (SPEAKERS, GRILLES, TELEPHONE INSTRUMENTS, RADIO
HANDSETS, ETC.) SHALL BE SALVAGED TO THE OWNER.
I. INFORMATION SHOWN FOR LOAD DESCRIPTIONS ON EXISTING PANELS WAS GAINED FROM ORIGINAL
BUILDING ELECTRICAL PLANS AND SHALL BE FIELD VERIFIED. CONFIRM LOAD ON EACH CIRCUIT OF ALL
EXISTING PANELS AND PROVIDE UPDATED TYPEWRITTEN CIRCUIT DIRECTORY (IN PLASTIC SLEEVE) FOR
EACH EXISTING PANELBOARD.
J. ANY LOADS REMOVED DURING DEMOLITION SHALL HAVE CONDUCTORS REMOVED BACK TO NEXT
REMAINING DEVICE OR TO EXISTING PANELS. ABANDONED BREAKERS SHALL BE LABELED "SPARE".
K. PROVIDE BLANK FILLER PLATES IN DEADFRONTS OF EXISTING PANELBOARDS UPON COMPLETION OF
PROJECT WHERE BREAKERS HAVE BEEN REMOVED.
A.ALL 15 AND 20AMPERE RECEPTACLES FOR BOTH DAMP AND WET LOCATIONS REQUIRED TO BE LISTED
WEATHER-RESISTANT (WR) TYPE PER CEC 406.9 (A) AND (B)
B.CEC 406.9(A) RECEPTACLES IN DAMP LOCATIONS: RECEPTACLES INSTALLED OUTDOORS IN A LOCATION
PROTECTED FROM THE WEATHER OR IN OTHER DAMP LOCATIONS SHALL BE AN ENCLOSURE FOR THE
RECEPTACLE THAT IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT PLUG CAP NOT
INSERTED AND RECEPTACLE COVERS CLOSE)
C.CEC 406.9(B) RECEPTACLES OF 15 AND 20AMP, 125 AND 250 VOLTS INSTALLED IN A WET LOCATION SHALL
HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS
INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BE
IDENTIFIED AS 'EXTRA-DUTY" OTHER LISTED PRODUCTS, ENCLOSURES, OR ASSEMBLIES PROVIDING
WEATHERPROOF PROTECTION THAT DO NOT UTILIZE AN OUTLET BOX HOOD NEED TO BE MARKED "EXTRA
DUTY"
EXCEPTION: 15 AND 20AMP, 125 THROUGH 250 VOLT RECEPTACLES INSTALLED IN A WET LOCATION AND
SUBJECT TO ROUTINE HIGH-PRESSURE SPRAY WASHING SHALL BE PERMITTED TO HAVE AN ENCLOSURE
THAT IS WEATHERPROOF WHEN THE ATTACHMENT PLUG IS REMOVED.
RECEPTACLES AT DAMP AND WET LOCATION
EL
E
C
T
R
I
C
A
L
G
E
N
E
R
A
L
N
O
T
E
S
E-001
A.DATA AND TV RACEWAYS AND BOXES:
a.PROVIDE AND INSTALL 4" SQUARE RECESSED JUNCTION BOX WITH 1-GANG RING. RUN 3/4" EMT
CONDUIT STUB TO ACCESSIBLE CEILING SPACE ABOVE FLOOR DATA MAX 3-CAT6A CABLES.
b.PROVIDE AND INSTALL 5" SQUARE RECESSED JUNCTION BOX WITH 1-GANG RING. RUN 1-1/4" EMT
CONDUIT STUB TO ACCESSIBLE CEILING SPACE ABOVE FLOOR DATA MAX 10-CAT6A CABLES.
BEFORE CONSTRUCTION, COORDINATE AND VERIFY ALL DATA AND TELEPHONE LOCATIONS WITH OWNER
OR ARCHITECT.
B.ALL NEW HORIZONTAL CABLES, RISER RATED (CMR) CABLES SHALL BE CAT6A (BERK-TEK #LANMARK-10G2 -
BLUE)
C.DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD
VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE,
ETC. AND SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER EQUIPMENT.
D.ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION, SHALL BE MOUNTED ON
OPPOSITE SIDES OF THE SAME STUD. COORDINATE BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS.
E.CAT6A CABLES, TOTAL LENGTH FROM IDF TO ENDPOINT SHALL NOT BE MORE THAN 295'-0", EC SHALL BRING
TO THE ATTENTION OF THE ENGINEER ANY LENGTHS IN EXCESS OF 295'-0".
F.ALL COMMUNICATION WORK SHALL COMPLY WITH CITY OF SAN LUIS OBISPO STANDARDS. OBTAIN
COMPLETE LIST OF STANDARDS, AND ADHERE ACCORDINGLY.
G.TEST ALL NEW AND EXISTING RE-USE CABLES.
CONDUIT SYSTEMS NOTES
CONDUIT SYSTEMS USED ON THIS PROJECT SHALL BE AS FOLLOWS
1. PVC SCHEDULE 40 - underground/below slab with GRS elbows and risers tape wrapped).
2.ELECTRICAL METALLIC CONDUIT (EMT) - above grade/slab in building construction and where exposed above 8'-0" aff.
3.GALVANIZED RIGID STEEL (GRS) - where exposed below 8'-0" aff. and/or where subject to physical damage.
4.FLEXIBLE STEEL CONDUIT - above ceilings and/or concealed in building construction (seal tight flex required in exterior
locations).
6.MC CABLE NOT ALLOWED.
REFER TO SECTION 260533 & 260500 OF SPECIFICATIONS FOR ADDITIONAL INFORMATION. CONDUITS SHALL BE
MINIMUM 3/4" UNLESS OTHERWISE NOTED. CONDUIT SIZES, WHERE NOT NOTED ON THE DRAWINGS, SHALL BE
SIZED FOR MAXIMUM 40% FILL PER CEC 310-6.
ADDITIONAL CONDUIT REQUIREMENTS.
-ROUTE CONDUIT(S) BELOW GRADE OR ABOVE CEILING SO THAT WALL OUTLETS, DEVICES, AND CONDUITS IN
ALL EXPOSED BRICK WALL LOCATIONS SHALL BE RECESSED MOUNTED INSIDE BRICK. LOCATE DEVICES AT
CELL WITH REINFORCEMENT CENTER AT BRICK AND/OR ONE CELL OVER AWAY FROM JAMB. REFER TO
ARCHITECTURAL AND STRUCTURAL PLANS FOR CMU WALL LOCATIONS SECTIONS, AND DETAILS.
- REFER TO ELECTRICAL DETAILS FOR METAL PIPE PENETRATION THRU FIRE RATED WALL. PENETRATION OF
FIRE-RESISTIVE WALLS AND FLOOR CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SECTION 714.
- REFER TO ELECTRICAL DETAIL FOR DEVICE INSTALLATION FOR FIRE RATED WALLS.
-NO CONDUITS OR PIPING IN ANY SPACE SHALL BE EXPOSED AT THE CEILING AND WALL (COORDINATE WITH
ALL DISCIPLINES PRIOR TO CONSTRUCTION). LOCATE ALL CONDUIT WITHIN WALLS
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
1
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
0
0
2
-
E
L
E
C
T
R
I
C
A
L
L
E
G
E
N
D
&
A
B
B
R
E
V
I
A
T
I
O
N
S
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
POWER LEGEND
NOTE: INTERPRET IN CONTEXT
MISCELLANEOUS
CONDUIT/WIRE
LIGHT FIXTURES
CONVENTIONS
LEGEND
3103
NUMBERED SHEET NOTES: REFERS TO NOTES ON SAME SHEET
AS REFERENCE
DETAIL REFERENCE:
Z = DETAIL DESIGNATION
X = SHEET NUMBER REFERENCE
Z
X
FEEDER SCHEDULE DESIGNATION
(EXAMPLE: 3103 = 310 AMPERE, 600V, 3 CURRENT CARRYING
CONDUCTORS, PREFIXES: 'M' INDICATES MEDIUM VOLTAGE, 'CO14'
INDICATES CONDUIT ONLY, QUANTITY (1) AND SIZE (4"))
X
MECHANICAL SYSTEMS TAG
(REFER TO MECHANICAL SHEETS)
Y = UNIT TYPE
X = UNIT NUMBER
Y
X
COMBINATION STARTER
MAGNETIC CONTACTOR
DAMPER MOTOR
HUMIDISTAT
SURFACEMOUNT CABINET
FLUSHMOUNT CABINET
SURFACEMOUNT PANEL
FLUSHMOUNT PANEL
PUSHBUTTON
H
M
DM
SPEAKER- WALLMOUNT
SPEAKER- CLG FLUSHMOUNT
HEADSET OUTLET
AUXILIARY INPUT
MICROPHONE INPUT
CLOCK/SPEAKER WALLMOUNT
SPEAKER- CLG FLUSHMOUNT
VANDAL-RESISTANT
VOLUME CONTROL
V S
SEMI-FLUSH
S
A
HS
V
M
S
S
CIRCUIT BREAKER
FUSIBLE SWITCH
GROUND
THERMOSTAT
SURFACE
A LETTER ADJACENT INDICATES
(ARROW INDICATES DIRECTION)
FIXTURE TYPE
RECESSED WALL MOUNT
EXIT LIGHT- CEILING
EXIT LIGHT- WALL
WALL-PACK
CLOCK
PHASEØ
T
MOTOR
UPLIGHT- FLUSH IN GRADE
POLE LIGHT- DECORATIVE
PENDANT LINEAR
UNDERCABINET LIGHT
TANDEM-WIRED LAMPS
BOLLARD
STRIP UON
DIRECTIONAL FLOOD
EMERGENCY FIXTURE
POLE LIGHT
TRACK LIGHT
CEILING SURFACEMOUNT
WALL SURFACEMOUNT
RECESSED DOWNLIGHT
RECESSED WALLWASH
RECESSED
PENDANT MOUNT
(E) POWER HOMERUN
INDICATES LINE CONTINUES
WIRE LINE- CONTINUES
CONDUIT STUB (W/MARKER)
VERTICAL CONDUIT RUN
FLEXIBLE CONNECTION
SURFACEMOUNT RACEWAY
CORD W/PLUG
LOW VOLTAGELV
CONDUIT SEAL
NEW POWER HOMERUN
(3 HOTS & NEUT SHOWN)
ISOLATED GROUND
EXISTING TO REMAIN
NEW
E
UNDERGROUND
WALL MOUNTED CLOCK
CLOCK/SPEAKER COMBINATION S
SAFETY DISCONNECT
SOUND
END OF LINE RESISTOR
DUCT SMOKE DETECTOR
VISUAL- VISUAL DEVICE
MANUAL PULL STATION
HORN- AUDIBLE DEVICE
AUDIBLE/VISUAL
SMOKE DETECTOR
HEAT DETECTOR
BELL
TAMPER SWITCHT
P
FLOW SWITCH
AV
V
F
H
FIRE ALARM CONTROL PANEL
REMOTE POWER SUPPLYRPS
SPEAKER/VISUALSV
FIRE ALARM
SFD SMOKE FIRE DAMPER
SDCO
SD D
SD
H
B
SMOKE DETECTOR WITH CO
WALL SURFACE MOUNT
LINEAR TYPE
LED COVE & UNDERCABINET
LIGHT PER FIXTURE SCHEDULE
J JUNCTION BOX
SDV SMOKE DETECTOR WITH VISUAL
A AMPERE
AB AMP BREAKER
ABAND ABANDONED
ABV ABOVE
AC ALTERNATING CURRENT
AC-#AIR CONDITIONER
ADJ ADJACENT
AF AMP FUSE, AMP FRAME
AFF ABOVE FINISH FLOOR
AFG BOVE FINISH GRADE
AIC AMPERES INTERRUPTING CAPACITY
Al ALUMINUM
AS AMP SWITCH RATING
ATS AUTOMATIC TIME SWITCH
ATS AUTOMATIC TRANSFER SWITCH
AV AUDIBLE/AUDIO VISUAL
AWG AMERICAN WIRE GAGE
BFG BELOW FINISH GRADE
BIL BASIC IMPULSE LEVEL
BLDG BUILDING
C CONDUIT
-C-CATV CONDUIT
CAB'T CABINET
CATV CABLE TELEVISION
CB CIRCUIT BREAKER, CODE BLUE
CBC CA. BUILDING CODE
CEC CA. ELECTRICAL CODE
CA. ENERGY COMMISSION
CF COMPACT FLUORESCENT
CFC CALIFORNIA FIRE CODE
CLG CEILING
CL CENTER LINE
CKT CIRCUIT
CNT'R CONTRACTOR
C.O.CONDUIT ONLY (W/PULLROPE)
COND CONDUIT, CONDUCTOR
CR CRITICAL BRANCH
CSFM CALIFORNIA SFM
CT CURRENT TRANSFORMER
Cu COPPER
CU-#CONDENSING UNIT
D DEPTH
DC DIRECT CURRENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DPST DOUBLE POLE SINGLE THROW
DW DISHWASHER
EM EMERGENCY
(E)EXISTING
EA EACH
EB ELECTRONIC BALLAST
EC ELECTRICAL CONTRACTOR
EC-#EVAPORATIVE COOLER
EF-#EXHAUST FAN
EL EVENING LIGHT
ELEC ELECTRICAL
EM EMERG BATTERY BACKUP
EMERGENCY BALLAST
EMERG EMERGENCY
EOL END OF LINE
EQUIP'T EQUIPMENT
ES ENERGY SAVING
(EXN)(E) IN (N) LOCATION
(EXR)(E) TO BE (R)
EXT EXTERIOR
F FLUORESCENT
(F)FUTURE
F-#FURNACE
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FAT FIRE ALARM TERMINAL
FAU FORCED AIR UNIT
FBO FURNISHED BY OTHERS
FC-# FAN COIL
FLA FULL LOAD AMPS
FLR FLOOR
FLUOR FLUORESCENT
FS FUSIBLE SWITCH
FVNR FULL VOLTAGE NON-REVERSING
G GROUNDING CONDUCTOR
GC GENERAL CONTRACTOR
GD GARBAGE DISPOSAL
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GFI GROUND FAULT CIRCUIT
INTERRUPTER
GND GROUND
GRS GALVANIZED RIGID STEEL
GWS GANG WITH SWITCH
H HEIGHT, HIGH
HACR HEATING, AC & REFRIG
HID HIGH INTENSITY DISCHARGE
HO HIGH OUTPUT
HOA HAND-OFF-AUTO
hp HORSEPOWER
HPF HIGH POWER FACTOR
HPS HIGH PRESSURE SODIUM
IC INTERCOM
ID IDENTIFICATION
IDF INTERMEDIATE DISTRIBUTION FRAME
IF INSIDE FROST
IG ISOLATED GROUND
J-BOX JUNCTION BOX
k QUANTITY 1000
kVA KILOVOLTAMPS
kW KILOWATT
LC LIGHTING CONTACTOR
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LS LIFE SAFETY BRANCH
LT LIGHT
LTG LIGHTING
LV LOW VOLTAGE
MC MECHANICAL CONTRACTOR
MCA MINIMUM CKT AMPS
MCB MAIN CIRCUIT BREAKER
MCTB MAIN CATV TERMINAL BOARD
MCTC MAIN CATV TERMINAL CABINET
MDF MAIN DISTRIBUTION FRAME
MECH MECHANICAL
MFR MANUFACTURER
MFS MAIN FUSIBLE SWITCH
MH METAL HALIDE
MLO MAIN LUGS ONLY
MOCP MAXIMUM OCP
MPOE MINIMUM POINT OF ENTRY
MSB MAIN SWITCHBOARD
MT MOUNT
MT HT MOUNTING HEIGHT
MTS MANUAL TRANSFER SWITCH
MTTB MAIN TELEPHONE TERMINAL BOARD
MTTC MAIN TELEPHONE TERMINAL CABINET
MW MICROWAVE
N NEUTRAL (GROUNDED CONDUCTOR)
(N)NEW
N3R NEMA 3R
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NAT'L ELEC MANUFACTURER'S ASSOC
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OC ON CENTER
OCP OVERCURRENT PROTECTION
OD OUTSIDE DIAMETER
OH OVERHEAD
OSA OFFICE of the STATE ARCHITECT
OSHPD OFFICE of STATEWIDE HEALTH
PLANNING & DEVELOPMENT
OVLD OVERLOAD
P POLE
PA PUBLIC ADDRESS
PB PULLBOX
PC PULL CHAIN
PC PHOTOCELL
PC PLUMBING CONTRACTOR
ph PHASE
PNL PANEL
POC POINT OF CONNECTION
-PP-POWER PRIMARY
-PS-POWER SECONDARY
PV PHOTOVOLTAIC
(R)RELOCATE(D)
RECEPT RECEPTACLE
REF REFRIGERATOR
REQ'D REQUIRED
RLA RATED LOAD AMPS
RM ROOM
RMC RIGID METAL CONDUIT
RMV REMOVE
RPLC REPLACE
RS RAPID START
SC SIGNAL CABINET
SCC SHORT CKT CURRENT
SFM STATE FIRE MARSHAL
SHT SHEET
SL SLIMLINE, SWITCH LEG
SPEC SPECIFICATION
SPST SINGLE POLE SINGLE THROW
SQ SQUARE
STR'G STORAGE
SURF SURFACE
SVC SERVICE
SW SWITCH
T TRANSFORMER, TERMINAL
-T-TELEPHONE CONDUIT
(TBR)TO BE REMOVED
TC TIME CLOCK
TEL TELEPHONE
TELCO TELEPHONE COMPANY
TS TIME SWITCH
TSO TIME SWITCH OVERRIDE
TSP TWISTED SHIELDED PAIR
TTB TELEPHONE TERMINAL BOARD
TTC TELEPHONE TERMINAL CABINET
TX TRANSFORMER
TYP TYPICAL
TYP SIM TYPICAL SIMILAR
UC UNDERCABINET, UNDERCOUNTER
UG UNDERGROUND
UGPS UNDERGROUND PULL SECTION
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
USA UG SVC ALERT 800-642-2444
V VOLT
VA VOLT AMPERES
VAC VOLT ALTERNATING CURRENT
VHO VERY HIGH OUTPUT
VOLT VOLTAGE
VR VANDAL-RESISTANT
W WIDTH, WATT, WIRE
WH-#WATER HEATER
WP WEATHERPROOF (NEMA 3R)
XFMR TRANSFORMER
+48 INDICATES MOUNTING HEIGHT AFF
FIXTURE TYPE
LIGHTING PLAN
B-1,a
CIRCUIT NUMBER
A
POWER PLAN
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM DEVICES TO PANEL(S) PER DESIGNATIONS/CIRCUIT NUMBERS.
- EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AS INDICATED ON PANEL SCHEDULES.
- HOME RUN CONDUITS SHALL BE 3/4"C, MAX OF (3) BRANCH CIRCUITS PER CONDUIT.
-INCREASE HOME RUN CONDUIT SIZE TO 1"C FOR (4) BRANCH CIRCUITS OR MORE.
-(**) DENOTES SPECIAL DEVICE/NAMEPLATE REQUIREMENTS.
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM FIXTURES TO PANEL(S) AS
DESCRIBED BY CIRCUIT NUMBERS SHOWN.
- PROVIDE ALL WIRING BETWEEN FIXTURES AND CONTROL DEVICES AS DESCRIBED
IN REFERENCE NOTES AND/OR SHOWN BY SWITCHLEG DESIGNATIONS.
- EXIT AND EMERGENCY LIGHT FIXTURES SHALL BE CONNECTED TO AN
UNSWITCHED BRANCH CIRCUIT CONDUCTOR.
- HOME RUN CONDUITS SHALL BE 3/4"C., MAX OF (3) BRANCH CIRCUITS PER
CONDUIT.
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM MECH. EQUIPMENT TO PANELS.
SWITCHLEG DESIGNATION
(WHERE SHOWN)
DEVICE TYPE:
SEE LEGEND
MOUNTING HEIGHT: (WHERE NON-STANDARD)
W - 48" ABOVE FINISHED FLOOR
M - ABOVE COUNTER TOP (COORDINATION REQUIRED)
TV - MOUNT AT TV HEIGHT (COORDINATION REQUIRED)
CLG - CEILING MOUNT
SPECIAL CONFIGURATION:
WP - **WEATHER PROOF, PROVIDE WHILE IN USE COVER
GFI - **GROUND FAULT CIRCUIT INTERRUPTED
IG - ISOLATION GROUND
GWS - GANG WITH SWITCH
CONTROLLED RECEPTACLE:
(IF APPLICABLE)
SEE LIGHTING CONTROL DETAIL FOR
ADDITIONAL INFORMATION
CIRCUIT NUMBER:
BRACKETS ('[]') DENOTE
EXISTING CIRCUIT.
PANEL DESIGNATION
NOTE:THE INTENT OF THE DRAWINGS IS TO SHOW FIXTURE / DEVICE LOCATIONS AND PANEL DESIGNATIONS. ALL BRANCH CIRCUIT WIRING, MEETING THE
CRITERIA NOTED ABOVE, WILL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. LIGHTING AND POWER PLANS SHOW AN ABOVE CEILING
JUNCTION BOX / HOME RUN WITH CIRCUIT NUMBERS BY FIXTURES / DEVICES. PROVIDE ALL BRANCH CIRCUITING AS REQUIRED FOR A COMPLETE
INSTALLATION. DOCUMENT ALL BRANCH CIRCUITING ON AS-BUILT DRAWINGS ACCURATELY REFLECTING THE INSTALLATION.
CIRCUITING LEGEND
ABBREVIATIONS
20A DUPLEX RECEPTACLE
20A (GFCI) GROUND FAULT CURRENT INTERRUPTER DEVICE
20A MOUNT ABOVE COUNTER PER ADA.
MOUNT AT +48" MEASURED TO TOP OF BOX.
WHILE-IN USE NEMA 3R COVER (TAYMAC #MX4280S OR ENGINEER APROVED
EQUAL UNLESS OTHERWISE NOTED)
FLOOR MOUNTED OUTLET
GROUND BAR
20A CEILING MOUNTED OUTLET
GANG WITH SWITCH
DISCONNECT FUSE OR NON FUSED
20 DOUBLE DUPLEX RECEPTACLE
TELEVISION OUTLET. VERIFY MOUNTING HEIGHT PRIOR TO ROUGH-IN.
COMBINATION POWER/DATA FLOOR BOX.
20A SINGLE RECEPTACLE
20A DUPLEX- HALF SWITCHED
20A SWITCHED RECEPTACLE
J DROP CORD RECEPTACLE
208V 1Ø RECEPTACLE
20AMP DUPLEX OUTLET WITH TYPE A AND TYPE C USB CHARGER
SDS SMOKE DETECTOR WITH SOUND
NOTE: "C" NEXT TO NOTIFICATION
DEVICE ON PLANS DENOTES MOUNT AT
CEILING
J
SF
SF
WALL MOUNTED SYSTEM FURNITURE COMMUNICATION
CONNECTION.
EL
E
C
T
R
I
C
A
L
L
E
G
E
N
D
A
N
D
A
B
B
R
E
V
I
A
T
I
O
N
S
E-002
COMMUNICATION LEGEND
TELE POWER POLE
NEW FLUSH MOUNTED DATA OUTLET SHOWN. X DENOTES
TOTAL CAT6A CABLES AND PORT FACEPLATE
TV MOUNT DATA OUTLET AT TV HEIGHT. PROVIDE 1-CAT6A CABLE.
WALL MOUNTED SYSTEM FURNITURE POWER CONNECTION.
#
CAM
AP
SECURITY CAMERA
WIRELESS ACCESS POINT
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
1
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
0
0
3
-
E
L
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
A
N
D
S
C
H
E
D
U
L
E
S
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 (E) "MSB" SINGLE LINE DIAGRAM
(E) "MSB"
M
PRIMARY SECONDARY
800A BUS, 120/208V, 3 PHASE 4 WIRE
(E)
PANEL
A
PANEL
B
PANEL
C
(E)PRIM (E)SEC
(E)TRANSFORMER T-578
(E)
150A
3P
EXISTING EXISTING EXISTING
PANEL
D
EXISTING AC-1 AC-2 ELEVATOR
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
E-003
A.ILLUSTRATIONS AND/OR DIMENSIONS ARE APPROXIMATIONS ONLY
INTENDED TO REPRESENT BASIC FIXTURE TYPE; DO NOT USE AS
EXACT INFORMATION SOURCE. REFER TO MANUFACTURER CUT
SHEETS.
B.EXACT LOCATIONS: BEFORE CONSTRUCTION, VERIFY WITH
ARCHITECT EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL
LIGHT FIXTURES. SEE ARCHITECTURAL REFLECTED CEILING PLANS
AND ELEVATIONS AS APPLICABLE.
C.FIXTURE BRANCH CIRCUIT THROUGH-WIRING: VERIFY AND COMPLY
WITH FIXTURE MANUFACTURER RESTRICTIONS AS DETERMINED BY
UL. & NEC.
D.VERIFY CEILING TYPES/FINISHES FOR ALL RECESSED FIXTURES
PRIOR TO FORWARDING SUBMITTALS.
E.ALL RECESSED LUMINAIRES IN CEILINGS SHALL BE LISTED TYPE IC.
(E)
150A
3P
(E)
150A
3P
(E)
100A
3P
(E)
40A
3P
SPARE
(E)
200A
3P
(E)
200A
3P
(E)
150A
3P
(E) 800A
3P, MAIN
(E)
80A
2P
LEVEL 2
EV CHARGER
REFERENCE NOTES
1.EXISTING PANELBOARDS. SEE POWER / SIGNAL FLOOR PLANS FOR
LOCATION. INFORMATION LOAD DESCRIPTIONS ON EXISTING PANELS
WAS GAINED FROM ORIGINAL BUILDING ELECTRICAL PLANS AND
SHALL BE FIELD VERIFIED. CONFIRM LOAD ON EACH CIRCUIT OF ALL
EXISTING PANELS PROVIDE UPDATED TYPEWRITTEN CIRCUIT
DIRECTORY (IN PLASTIC SLEEVE) FOR EACH EXISTING PANELBOARD.
2.DESIGN IN SITE SCOPE SEPARATE PERMIT.
A.ALL CONDUCTORS SHALL BE COPPER WITH TYPE [THHN/THWN]
INSULATION UNLESS OTHERWISE NOTED.
B.ALL SWITCHES, CIRCUIT BREAKERS AND OTHER EQUIPMENT, AS
SPECIFIED, SHALL HAVE TERMINATION PROVISIONS LISTED AND
IDENTIFIED FOR USE WITH 75 DEG. CONDUCTORS, AND ALL FEEDER
CONDUCTORS, AND CONDUITS, ARE SIZE BASED ON USE OF 75 DEG.
C COPPER WIRES TYPE THWN/THHN.
C.ALL EQUIPMENT SHALL HAVE AN APPROVED TESTING LABORATORY
LABEL ATTACHED [UL, CSA, ETC.] (CEC 110-2).
SINGLE LINE DIAGRAM NOTES
FIXTURE SCHEDULE NOTES
LIGHTING
2 "MSB" LOAD CALCULATIONS
INTERIOR LIGHTING FIXTURE SCHEDULE
MAX.
VA.CATALOG NO.MANUFACTURERILLUSTRATIONTYPE LAMPING MOUNTING DESCRIPTIONVOLTAGE
D1
LITHONIA LDN4 40/10 LO4 AR
LD TRW MVOLT EZ1
MVOLT 11 LED
4000K
RECESSED 4" RECESSED LED DOWNLIGHT.
W1
LITHONIA FMVCCLS 24IN
MVOLT BN
MVOLT 18.12 LED
4000K
WALL ABOVE
MIRROR
2' CONTEMPORARY CYLINDER
VANITY
W2
LITHONIA MVOLT 34.86 LED
4000K
1 1 1 1
EXIT SIGN AND EMERGENCY LIGHTING FIXTURE SCHEDULE
MAX.
VA.CATALOG NO.MANUFACTURERILLUSTRATIONTYPE LAMPING MOUNTING DESCRIPTIONVOLTAGE
X1
ISOLITE EDC-EM-R-1-XX-XX
-MTEBP
MVOLT 5 LED UNIVERSAL UNIVERSAL MOUNT LED EXIT
SIGN WITH UNIVERSAL FIELD
SELECTABLE CHEVRONS AND
EMERGENCY BATTERY BACKUP.
X2
ISOLITE CMB-EM-R-U-XX
-MTEBP-L1
MVOLT 8 LED UNIVERSAL
XM
ISOLITE BUG-3W-WH-MB MVOLT 6 LED SURFACE
XM
E
ISOLITE OWL-EM-XX-MB MVOLT 17 LED WALL
UNIVERSAL MOUNT LED EXIT
SIGN AND EMERGENCY LIGHT
COMBO WITH UNIVERSAL FIELD
SELECTABLE CHEVRONS AND
EMERGENCY BATTERY BACKUP.
LED EMERGENCY LIGHT.
EXTERIOR LED EMERGENCY
LIGHT.
FMVCCLS 48IN
MVOLT BN
WALL ABOVE
MIRROR
4' CONTEMPORARY CYLINDER
VANITY
(SITE PROJECT)
2
1 ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
J
"B"
JJ
J
J
J
J J
J
J
J
J
JJJJJJ
V
J
JJ
J
J
J
J
J
(TBR)
(TBR)(TBR)
(TBR)
7
E-201
10
E-201
30A, 120/250V, 1Ø 1
ED-101
EXISTING TELEPHONE BACKBOARD
AND MAIN POINT OF ENTRY
"A"
"MSB"
"FACP"
S
S
(E)SAFE
B-16
B-16
B-16
B-16
B-16
B-16
B-22
B-22
B-3,26 B-3
B-3
B-26 B-26
B-3
B-3 B-3
B-3,26
B-3
B-3,26
B-2
B-2
B-2 B-19
B-2
B-19
B-2
B-2
B-6,15
B-9,10,12
J
B-4,6,17
B-10,11
A-4
A-4B-8B-13,14B-13,14
A-4
B-22
A-2
0
A-20
A-20
A-20
A-20B-28
B-28
A-20
A-1
8
B-2
B-2
A-9
A-9A-24
A-9
A-9
A-4
A-16
A-15
A-13
A-13
A-13
A-17
A-13
A-13
A-16
A-9
A-9
A-16 A-16
A-36
A-36A-36
A-15
A-15
A-16
JJ
SHARED
OFFICE
BUREAU
SERGEANT
107
DETECTIVE
EQUIPMENT
106
DRONE/EQUIP.
STORAGE
105
STAIR
MEN
118
WOMEN
119
HALL
115
JAN.
ELECTRICAL
120
CIRCULATION
130
BRIEFING
ROOM
'122
MEETING
125
OFFICE
124
ELEV.
STAIR
LOBBY
100
STORAGE
111
OPEN
OFFICE
BREAK ROOM
OFFICE
HALL
2
2 2
(TBR)
2
(TBR)
2 3
4
4
+84"
6
42
24222
2
2
4
6 6
4 2
2
(TBR)
(TBR)
(TBR)
1 2
(TBR)
2
3 3
4
17
5
6
7
8
9
(EXR)
10
J
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
1
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
D
-
1
0
1
-
1
S
T
F
L
R
P
W
R
&
S
I
G
D
E
M
O
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
NORTH
SCALE:
POWER / SIGNAL DEMOLITION FIRST FLOOR PLAN
3/16"=1'-0"
PO
W
E
R
/
S
I
G
N
A
L
D
E
M
O
L
I
T
I
O
N
F
I
R
S
T
F
L
O
O
R
P
L
A
N
ED-101
NOTE: ALL DEVICES SHOWN ON THIS PAGE ARE EXISTING UNLESS
OTHERWISE NOTED)
1
EXISTING DATA RACK AT
ELECTRICAL ROOM
REFERENCE NOTES
1.REMOVE AND DISCONNECT OUTLET.
2.REMOVE AND DISCONNECT DATA WIRING FROM EXISTING DATA RACK.
3.REMOVE AND DISCONECT EXISTING OUTLET AT DEMO WALL. RE-USE
EXISTING BRANCH CIRCUITS AT NEW OUTLETS.
4.EXISTING FLOOR BOX SHOWN ON AS-BUILT. FIELD VERIFY EXACT
LOCATION UNDER CARPET. VERIFY EXISTING BRANCH CIRCUIT AND
LABEL.
5.DISCONNECT/REMOVE EXISTING JUNCTION BOX AT FLOOR. CAP
EXISTING CONDUIT.
6.EXISTING (17)CAT6 CABLES AT FLOOR. RE-USE (4)CAT6 FOR OUTLETS
AT NEW WALL. TONE EXISTING CABLES NOT USED AND DISCONNECT
CABLES AT EXISTING DATA RACK. PULL EXISTING CABLES FROM
CEILING SPACE. COORDINATE WITH CITY IT FOR ADDITIONAL
REQUIREMENTS PRIOR TO DEMO. CAP EXISTING CONDUITS.
7.RE-USE EXISTING BRANCH CIRCUIT TO POWER NEW OUTLETS AT NEW
WALL. INTERCEPT EXISTING BRANCH CIRCUIT ABOVE T-BAR CEILING
AND EXTEND NEW BRANCH CIRCUIT TO NEW OUTLETS.
8.EXISTING 6-DATA TO BE RELOCATED TO SOUTH WALL.
9.REMOVE EXISTING DOUBLE DUPLEX. RE-USE EXISTING BRANCH
CIRCUITS FOR NEW SYSTEM FURNITURE. INTERCEPT EXISTING BRANCH
CIRCUITS ABOVE-TBAR CEILING AND EXTEND NEW BRANCH CIRCUIT.
10.EXISTING FLOOR MOUNTED DATA RACK. PROVIDE AND INSTALL (2)48
CAT6A PORT AT EXISTING DATA RACK. HOMERUN ALL NEW FIRST
FLOOR CAT6A CABLES TO THIS RACK.
X ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
W
"D"
J
J
J
J
J
H
H
V
J
W
M M
J
J
M
J
J
J
HD
M
I
J
6
VI
D
E
O
S
J
J
J
J
H
8
E-201
9
E-201
V V
J
V
V
V
V
P
M
(E)SYSTEM
FURNITURE (POC)
J
(E)SYSTEM
FURNITURE (POC)
(E)ELEVATOR UNIT
AND DISCONNECT
V
V
V
"C"
3
2
1
1
(EXR)
(
E
X
R
)
(
E
X
R
)
(
E
X
R
)
MEETING
ROOM
202
PUBLIC AFFAIRS
MANAGER
205
BOS.
MANAGER
208
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
WOMENS
222
HALL
STAIRS
144
SERVER
216
EQUIP.
220
BREAK
ROOM
215CHIEF
214C
ADMIN
214A
DEPT.
CHIEF
213
DEPT.
CHIEF
211
ELEV.
MECH
112
COPY
ROOM
210
ELEV.
CONF.
202
TRAIN/HIRING
MANAGER
208
CRIME
ANALYST
209
222
22
2
442
2
2
2
2
2
2
2
2
3
6
2
2
4
4
2
2
4
4
2
J J J
444
3 3
J
4
1
ED-102
5
5
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
1
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
D
-
1
0
2
-
2
N
D
F
L
R
P
W
R
&
S
I
G
D
E
M
O
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
REFERENCE NOTES
1.REMOVE EXISTING SURFACE MOUNT RACEWAY AT THIS AREA.
2.DISCONNECT EXISTING MOTORIZED SCREEN AND RECONNECT TO NEW
LOCATION.
3.PROTECT EXISTING FLOOR BOXES IN THIS ROOM.
4.EXISTING WALL MOUNTED DATA RACK. PROVIDE AND INSTALL (1)24
CAT6A DATA PORT. HOMERUN ALL NEW SECOND FLOOR CAT6A TO THIS
CABINET.
5.EXISTING SYSTEM FURNITURE CONNECTIONS. RE-USE (2) CAT6 CABLES
AND TERMINATE TO NEW WALL TV OUTLETS. RE-USE THE REST OF THE
CAT6 CABLES AND TERMINATE TO FACEPLATE AND STANDARD HEIGHT.
FIELD VERIFY EXACT LOCATION OF SYSTEM FURNITURE. FURNITURE
WERE IN THE WAY TO VERIFY IF THE SOUTH PILLAR HAD CONNECTIONS.
RE-USE EXISTING BRANCH BRANCH CIRCUIT TO POWER NEW OUTLETS
AT NEW WALL.
NORTH
SCALE:
POWER / SIGNAL DEMOLITION SECOND FLOOR PLAN
3/16"=1'-0"
PO
W
E
R
/
S
I
G
N
A
L
D
E
M
O
L
I
T
I
O
N
S
E
C
O
N
D
F
L
O
O
R
P
L
A
N
ED-102
NOTE: ALL DEVICES SHOWN ON THIS PAGE ARE EXISTING UNLESS
OTHERWISE NOTED)
EXISTING DATA RACK AT
ELECTRICAL ROOM1
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
TV TV
TV
TV
J
B-6,15
TV TV TV
J
A-3
1
J
A-38,40
TV
J
4
CLGCLG
3
2
11
5
(E) "A"
(E) "MSB"
(E) "FACP"
8
SF
SF
J
12
1 1
1
1
12
1
J
B-3,26 B-3
B-3 B-3
B-3,26
B-3
B-3,26B-3(N)6 (N)
3
3 (N)(N)
(E)(E)
(E)(E)
(E)
B-3,26
B-26
(N)
3
3
3
3
3
3
3
3
3
3
(E)
B-2
B-2
J
B-10,11
B-10
B-10
3
B-10
J
A-4
B-13
3
(E)(E)A-4B-8 (E)
B-22
A-1
8
(N)6 (E)(E)(E)
(E)
A-20
A-20
A-20B-28
B-28
A-20
(E)
(E)
(E)
(E)
(E)
(E)
A-9
A-9
G
G
10
6
CKT, B-6
CKT, B-6
CKT, B-6
CKT, B-6 CKT, B-15
CKT, B-6
CKT, B-15
CKT, B-15 CKT, B-15
CKT, B-15
(N)(N)
(N)
(N)
(N)
(N)
(N)(N)
(E)
(N)
(N)
(N)
(N)
6
(N)
(N)
(N)(N)
(N)
9
7
7
(E) "B"8
SHARED
OFFICE
126
BUREAU
SERGEANT
107
DETECTIVE
EQUIPMENT
106
DRONE/EQUIP.
STORAGE
105
STAIR
MEN
118
WOMEN
119
HALL
115
JAN.
ELECTRICAL
120
CIRCULATION
130
BRIEFING
ROOM
122
MEETING
125
OFFICE
124
ELEV.
STAIR
LOBBY
100
STORAGE
111
OPEN
OFFICE
BREAK ROOM
121
OFFICE
123
STORAGE
133
HALL
114
AP (N)
AP
(N)
(N)G
A-17
13
38
38
38
38
14
(N)
15
15
(E)
2
(E)
2
(E)
3
(E)
4
(E)
4
(E)
4
(E)
2
(E)
4222
(E)
2
(E)
4
6 6
(N)
40
2
19
18
18
17
CAM
16
(N)
21
J
5
(EXN)
20
18
(E)(E)(E)
21
5
1
ED-101
22
(E)
(E)
A-15
21
(N)6
(E)
(E)(E)
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
1
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
1
0
1
-
1
S
T
F
L
R
P
W
R
&
S
I
G
F
L
R
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
REFERENCE NOTES
1.PROVIDE 120V DEDICATED CIRCUIT FOR DOOR ACCESS CONTROL
PANEL. COORDINATE EXACT LOCATION WITH CITY VENDOR PRIOR TO
ROUGH-IN. CONNECT TO EXISTING SPARE BREAKER AT PANEL "A".
2.CONNECT TO MOTORIZED SCREEN. COORDINATE WITH
MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN.
3.MOTORIZED SCREEN CONTROLLER. PROVIDE WIRING TO MOTORIZED
SCREEN PER MANUFACTURER INSTALLATION GUIDE.
4.PROVIDE 120V CONNECTION TO PROJECTOR. VERIFY EXACT LOCATION
WITH OWNER PROVIDED EQUIPMENT.
5.EXTEND EXISTING BRANCH CIRCUIT.
6.SYSTEM FURNITURE POINT OF CONNECTION. RE-USE EXISTING BRANCH
CIRCUITS LOCATED ABOVE T-BAR CEILING. INTERCEPT AND EXTEND
BRANCH CIRCUITS TO SYSTEM FURNITURE. COORDINATE WITH SYSTEM
FURNITURE MANUFACTURE.
7.REPLACE EXISTING OUTLET WITH NEW GFCI OUTLET AND COVERPLATE.
8.EXISTING PANEL.
9.EXTEND EXISTING RECEPTACLE BRANCH CIRCUIT IN THIS ROOM TO
NEW OUTLET(S).
10.EXISTING DATA OUTLET BOX IN THIS SYSTEM FURNITURE. FIELD VERIFY
EXACT LOCATION. PROVIDE (3)NEW CAT6A CABLES. TYPICAL AT
SYSTEM FURNITURES.
11.THIS DATA OUTLET FOR SYSTEM FURNITURE WILL REQUIRE A BOX AND
1-1/5" CONDUIT TO ACCOMMODATE (12)CAT6A CABLES.
12.PROVIDE 120V DEDICATED CIRCUIT FOR MOTORIZED BLACK OUT
SHADES. COORDINATE WITH MANUFACTURER INSTALLATION GUIDE
PRIOR TO ROUGH-IN.
13.CONNECTION TO NEW DRINKING FOUNTAIN. EXTEND EXISTING CIRCUIT
FROM BREAK ROOM OUTLET.
14.PROVIDE (2)20A/1P BREAKER TO MATCH EXISTING TO SPACES 38 AND
40. PROVIDE UPDATED TYPED PANEL SCHEDULE.
15.WIRELESS ACCESS POINT FURNISHED AND INSTALLED BY OWNER. EC
TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE.
PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE.
16.SECURITY CAMERA FURNISHED AND INSTALLED BY OWNER. EC TO
PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE.
PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE.
17.PROVIDE 15FT TELE-POWER ONE COMPARTMENT POLE FOR (18)CAT6A
TO TERMINATE AT SYSTEM FURNITURE DATA OUTLET BOXES.
(WIREMOLD 30TC-2WH) EC TO PROVIDE ALL ACCESSORIES FOR A
COMPLETE WORKING SYSTEM.
18.INTERCEPT EXISTING BRANCH CIRCUIT AT ACCESSIBLE CEILING SPCE
NEAR EXISTING PILLAR AND EXTEND TO NEW OUTLET(S).
19.RE-USE EXISTING CAT6 CABLES AND TERMINATE AT TV AND STANDARD
HEIGHT.
20.NEW LOCATION OF EXISTING DATA OUTLETS.
21.REPLACE EXISTING DUPLEX OUTLET WITH DOUBLE DUPLEX. CHANGE
BOX, RING, DEVICE AND PLATE.
22.INSTALL 2-3" (EMT) CONDUIT SLEEVES ABOVE T-BAR CEILING TO FIRST
FLOOR DATA RACK FOR NEW LOW VOLTAGE WIRING.
NORTH
SCALE:
POWER / SIGNAL FIRST FLOOR PLAN
3/16"=1'-0"
PO
W
E
R
/
S
I
G
N
A
L
F
I
R
S
T
F
L
O
O
R
P
L
A
N
E-101
NOTE: CUT AND PATCH EXISTING WALLS WHERE
NEW OUTLETS ARE SHOWN.
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
UP
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
2
(E)
(E)
TV
TV
3
8
(E)
TV TV
3
TV TV
3
J
J
3
CLGCLG
(E)(E)
(E)(E)(E)
(E)
(E)
(E)
(E)
(E)
(N)
C-34,36
TV
(E)
(EXN)
3
C-38
11
1 (E) "C"
1 (E) "D"
4
5
6
10
(E)
(E)
7
7
7
(E)
DS
1
(IDU)
208V, 1ɸ
0.5 MCA
15 MOCP
2 12
M
13
C-40/42
14
15
36
34
36
36
36
34
16
(E)
G
(E)
G
17
17
2
(N)
(N)
(N)(N)
3
3
(N)
(N)
(N)
(N)
(E)
3
(E)(E)
(E)(E)(E)
(E)
6
1
1
6
1M
(EX
N
)
(EX
N
)
(EX
N
)
(N)
31
M
(N)
G,M
(N)
G,M
G,M G,M
18
(EXN)
MEETING
ROOM
202
PUBLIC AFFAIRS
MANAGER
205
BOS.
MANAGER
208
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
WOMENS
222
HALL
STAIRS
144
SERVER
216
EQUIP.
220
BREAK
ROOM
215
CHIEF
214C
ADMIN
214A
DEPT.
CHIEF
213
DEPT.
CHIEF
211
ELEV.
MECH
112
COPY
ROOM
210
ELEV.
CONF.
202
TRAIN/HIRING
MANAGER
208
CRIME
ANALYST
209
JAN.
(E)
(E)
TV
TV
3
1
(E)
(E)(E)(E)(E)
AP
(N)
AP
(N)
19
19
J J J
4
4
4
(E)(E)(E)
20
(E)
2
(E)
2
(E)
2
(E)
2
(E)
2
(E)
2
(N)
36(E)
6
(E)
2
(E)
4
(E)
4
(E)
2
(E)
2
M
2
(E)
2
(E)
2
(E)
2
(E)
2
(E)
2
(E)
2
(E)
3
(E)
6
(E)
2
(E)
2
(E)
4
(E)
4
(E)
2
W
2
(E)
4
(E)
4
3
22
22
22
6
6
23
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
1
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
1
0
2
-
2
N
D
F
L
R
P
W
R
&
S
I
G
F
L
R
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
REFERENCE NOTES
1.EXISTING BRANCH CIRCUIT PANELBOARD.
2.REPLACE EXISTING DUPLEX OUTLET WITH NEW DOUBLE DUPLEX
OUTLET.
3.EXTEND EXISTING RECEPTACLE BRANCH CIRCUIT IN THIS ROOM TO
NEW OUTLET(S).
4.CONNECT TO MOTORIZED SCREEN. COORDINATE WITH
MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN.
5.MOTORIZED SCREEN CONTROLLER. PROVIDE WIRING TO MOTORIZED
SCREEN PER MANUFACTURER INSTALLATION GUIDE.
6.PROVIDE 120V CONNECTION TO PROJECTOR. VERIFY EXACT LOCATION
WITH OWNER PROVIDED EQUIPMENT.
7.RE-USE EXISTING BRANCH CIRCUIT FROM EXISTING SYSTEM
FURNITURE CONNECTION.
8.RELOCATE EXISTING RECEPTACLE AND DATA OUTLET TO BE ABOVE
NEW COUNTER SPACE. INTERCEPT EXISTING BRANCH CIRCUIT TO NEW
LOCATION. PROVIDE NEW DUPLEX DEVICE AND PLATE.
9.NOT USED.
10.LOCATE FOR NEW COPIER.
11.PROVIDE NEW DEDICATED CIRCUIT AND OUTLET FOR EXISTING
REFRIGERATOR.
12.EXISTING WALL MOUNTED DATA RACK.
13.PROVIDE LINE VOLTAGE CONNECTION TO MECHANICAL UNIT.
ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION WITH
MECHANICAL PLANS AND PROVIDE 2-POLE, NEMA 1 DISCONNECT PER
MANUFACTURER'S REQUIREMENTS.
14.NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C".
PROVIDE NEW 20A/2P CIRCUIT BREAKER IN PANEL AS DESIGNATED TO
MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1)
#12 CU GROUND.
15.NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C".
PROVIDE NEW 20A/1P CIRCUIT BREAKER IN PANEL AS DESIGNATED TO
MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1)
#12 CU GROUND.
16.NEW 20A BRANCH CIRCUITS TO EXISTING PANEL "C". PROVIDE (2) NEW
20A/1P CIRCUIT BREAKERS IN PANEL AS DESIGNATED TO MATCH
EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (4) #12 THWN AND (1) #12 CU
GROUND.
17.REPLACE EXISTING OUTLET WITH NEW GFCI OUTLET AND COVER.
18.REPLACE EXISTING SWITCH AND OUTLET WITH NEW DEVICE AND
PLATES. PROVIDE NEW OUTLET AS SHOWN AND EXTEND EXISTING
BRANCH CIRCUIT. RE-USE EXISTING BRANCH CIRCUIT FROM EXISTING
OUTLET IN THIS LOCATION.
19.WIRELESS ACCESS POINT FURNISHED AND INSTALLED BY OWNER. EC
TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE.
PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE.
20.MOVE EXISTING OUTLET TO NEW WALL. INTERCEPT EXISTING BRANCH
CIRCUIT AND EXTEND TO NEW LOCATION. PROVIDE NEW DEVICE AND
COVER PLATE.
21.RE-USE EXISTING CAT6 CABLES AND TERMINATE AT NEW TV OUTLET
22.TERMINATE ALL EXISTING CAT6 AT EXISTING SYSTEM FURNITURE
LOCATION AT WALL OUTLET AT STANDARD HEIGHT. ASSUMED
(26)EXISTING CAT6 CABLES FROM EXISTING SYSTEM FURNITURE.
23.PROVIDE 2"C (EMT) SLEEVE ABOVE T-BARD CEILING FROM 2ND FLOOR
DATA CABINET FOR NEW CAT6A CABLES.
NORTH
SCALE:
POWER / SIGNAL SECOND FLOOR PLAN
3/16"=1'-0"
PO
W
E
R
/
S
I
G
N
A
L
S
E
C
O
N
D
F
L
O
O
R
P
L
A
N
E-102
NOTE: CUT AND PATCH EXISTING WALLS WHERE
NEW OUTLETS ARE SHOWN.
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
4
-
OS
OS
(EXR)(EXR)(EXR)
(TBR)
(TBR)(TBR)
3
-
(TBR)
(TBR)
SHARED
OFFICE
BUREAU
SERGEANT
107
DETECTIVE
EQUIPMENT
106
DRONE/EQUIP.
STORAGE
105
STAIR
MEN
118
WOMEN
119
HALL
115
JAN.
ELECTRICAL
120
CIRCULATION
130
BRIEFING
ROOM
'122
MEETING
125
OFFICE
124
ELEV.
STAIR
LOBBY
100
STORAGE
111
OPEN
OFFICE
BREAK ROOM
OFFICE
HALL
2
-
3
(EXR)
2
OS
OS
(EXR)3
(EXR)
(NL)
(NL)
X2
(NL)
(NL)
6
(N)XM
(N)
(NL)
(NL)
XM
7
4
4 OS
4 OS
(N)
XME
9
(NL)
10
10 10
10
(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)
(E)
(E)
(E)(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)
(E)(E)
(E)(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)(E)(E)
(E)
(E)
(E)(E)
(E)
(E)
(E)(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)
(E)
(E)
(E)
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG10
10
10(N)
CLG
(N) XM
7
5
-
(EXR)
12
(EXN)(EXN)(EXN)RPP
WS
WS,D
(N)
WS
OSOSOSOS
WS
OSOSOSOS
1
SHARED
OFFICE
SHARED
OFFICE
126
BUREAU
SERGEANT
OS
D1
W1
D1
1
1
W1
MEN
118
WOMEN
119
OS
OS
OS
XM
XMEOS
X2
(EXN)(EXN)
9
(N)XM
10
6
4
4
4
OS
4
(N)XM
10
(N) XM
10
(E)
(E)
(E)
(E)
(E)
(E)
(E)(E)
J
11 (N)X2
(EXN)
(NL)
5
(EXN)
9
(N)
X1
X2
(E)
(E)
(E)
(EXN)
(NL)
(N)
XME
(N) XM
CLG
J
OS
(E)
(EXN)
12
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
2
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
1
1
1
-
1
S
T
F
L
R
L
T
G
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 EXISTING FIRST FLOOR LIGHTING PLAN
SCALE: 1/8"=1'-0"
4 PARTIAL FIRST FLOOR LIGHTING PLAN AT SHARED OFFICE
SCALE: 1/4"=1'-0"
REFERENCE NOTES
1.EXTEND EXISTING LIGHTING BRANCH CIRCUIT IN THIS ROOM TO NEW
LIGHT FIXTURES AND ASSOCIATED CONTROLS.
2.REPLACE EXISTING EXIT SIGN WITH EMERGENCY WITH NEW.
3.REMOVE WALL MOUNTED EXIT SIGN. PROVIDE NEW CEILING MOUNT
EXIT SIGN AT NEW LOCATION. EXTEND EXISTING BRANCH CIRCUIT
AT NEW LOCATION.
4.REPLACE EXISTING OCCUPANCY SENSOR WITH NEW ULTRASONIC
OCCUPANCY SENSOR.
5.THESE SWITCHES CONTROL THE EXISTING DOWNLIGHTS AT OPEN
OFFICE. LABEL SWITCHES.
6.REPLACE EXISTING EMERGENCY LIGHTING WITH NEW.
7.PROVIDE NEW EMERGENCY LIGHTING AT MID STAIR LANDING.
EXTEND EXISTING BRANCH CIRCUIT.
8.EXISTING EMERGENCY LIGHTING WAS CONNECTED TO AN OUTLET.
DISCONNECT AND REMOVE AND EXTEND EXISTING BRANCH CIRCUIT
FROM EXISTING LIGHT IN THE SAME ROOM.
9.PROVIDE NEW EXTERIOR EMERGENCY LIGHTING EXTEND EXISTING
BRANCH CIRCUIT FROM NEAREST UNSWITCHED LIGHTING BRANCH
CIRCUIT.
10.PROVIDE NEW INTERIOR EMERGENCY LIGHTING. EXTEND EXISTING
BRANCH CIRCUIT FROM UNSWITCHED LIGHTING BRANCH CIRCUIT.
11.PROVIDE NEW INTERIOR EXIT SIGN WITH EMERGENCY LIGHTING.
EXTEND EXISTING BRANCH CIRCUIT FROM UNSWITCHED LIGHTING
BRANCH CIRCUIT.
12.EXISTING SWITCH TO BE RELOCATED TO NEW WALL. EXTEND LIGHT
EXISTING BRANCH CIRCUIT TO NEW LOCATION. BLANK EXISTING
SWITCH LOCATION. PROVIDE NEW OCCUPANCY WALL SWITCH.
L
I
G
H
T
I
N
G
F
I
R
S
T
F
L
O
O
R
P
L
A
N
E-111
PARTIAL FIRST FLOOR
3 LIGHTING PLAN AT RESTROOMS
SCALE: 1/4"=1'-0"
NORTH
PARTIAL FIRST FLOOR
2 LIGHTING PLAN AT LOBBY
SCALE: 1/4"=1'-0"
5 LIGHTING PLAN AT STORAGE 11
SCALE: 1/4"=1'-0"
PARTIAL FIRST FLOOR
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
UP
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
3
-
2
-
MEETING
ROOM
202
PUBLIC AFFAIRS
MANAGER
205
BOS.
MANAGER
208
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
WOMENS
222
HALL
STAIRS
144
SERVER
216
EQUIP.
220
BREAK
ROOM
215CHIEF
214C
ADMIN
214A
DEPT.
CHIEF
213
DEPT.
CHIEF
211ELEV.
MECH
112
COPY
ROOM
210
ELEV.
CONF.
202
TRAIN/HIRING
MANAGER
208
CRIME
ANALYST
209
(NL)
(NL)
(NL)
(NL)
(NL)
2
(NL)
(TBR)(TBR)
(TBR)
(TBR)
(TBR)(EXR)
3
3
(EXR)
(EXR)
(EXR)
(E)
XM
4
4
4
4
4
XM4
(TBR)
(TBR)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)
(E)
(E)(E)(E)
(E)
(E)
(E)(E)
(E)(E)
(E)
(E)(E)
(E)
(E)
(E)
(E)
(E)
(E)(E)
(E)(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(TBR)
(TBR)
(E)
(E)(E)
(E)
(E)(E)
(E)
(E)
(E)(E)
(E)
(E)
(N) XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
4
2
(N) XM
(CLG)
4
(E)
(E)(E)
(E)(E)(E)
(E)(E)
(E)
(E)(E)
(E)(E)
(E)(E)
(E)
(E)
WS
OSOSOSOS
WS
OSOSOSOS
WS,D
RPP
WS
RPP
WS
WS,D
WS,D
a a
aa b b
bb
b
b
b
a
1
1
CHIEF
214C
ADMIN
214A
(EXN)
W1
D1
D1
D1
D1 D1
D1
D1
D1
W2
OS
LV
OS
LV
LV LV
1
1
OS
LV
PP
OS
LV
LV
LV
LV
MENS
129
WOMENS
222
JAN.
(EXN)
(EXN)
5
6
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
2
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
1
1
2
-
2
N
D
F
L
R
L
T
G
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 EXISTING SECOND FLOOR LIGHTING FLOOR PLAN
SCALE: 1/8"=1'-0"
3 PARTIAL SECOND FLOOR LIGHTING PLAN @ ADMIN/CHIEF
SCALE: 1/4"=1'-0"
BATTERY POWERD WALL DIMMER, 1 GANG
1-POLE 0-10V DIMMING (NLIGHT AIR #RPODB DX)
WS
D,WS
WIRELESS POWER RELAY PACK. 0-10V DIMMING
(NLIGHT AIR #RPP20)
RPP
WS
OSOSOSOS
CEILING OCC SENSOR BATTERY POWERED
(NLIGHT AIR #RCMSB 7 AR)
LIGHTING CONTROL SYMBOLS LEGEND
(EXR) = EXISTING TO BE RELOCATED
(EXN) = EXISTING NEW LOCATION
(E) = EXISTING
(E)EXISTING SWITCH TO REMAIN
(TBR)EXISTING SWITCH TO BE REMOVED
LI
G
H
T
I
N
G
S
E
C
O
N
D
F
L
O
O
R
P
L
A
N
E-112
PARTIAL SECOND FLOOR
2 LIGHTING PLAN AT RESTROOMS
SCALE: 1/4"=1'-0"
REFERENCE NOTES
1.EXTEND EXISTING LIGHTING BRANCH CIRCUIT IN THIS ROOM TO NEW
LIGHT FIXTURES AND ASSOCIATED CONTROLS.
2.REPLACE EXISTING EMERGENCY LIGHTING WITH NEW.
3.EXISTING SWITCH TO REPLACE WITH NEW DEVICE AND COVER
PLATE.
4.PROVIDE NEW EMERGENCY LIGHT. EXTEND BRANCH CIRCUIT FROM
UNSWITCH LIGHTING BRANCH CIRCUIT.
5.NEW LOCATION OF EXISTING EXIT SIGN. COVER CHEVRON.
INTERCEPT EXISTING BRANCH CIRCUIT FROM OLD LOCATION AND
EXTEND TO NEW LOCATION.
6.NEW LOCATION OF EXISTING LIGHT. INTERCEPT EXISTING BRANCH
CIRCUIT FROM OLD LOCATION AND EXTEND TO NEW LOCATION.
NORTH
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
3.4
2.4
2.1
2.5
5.1
8.8 4.4 2.7
0.8 1.0
0.9
0.8
5.8
3.1
2.5
2.7
5.1
1.00.30.3
0.8
0.2
0.7 2.4
3.74.2
2.3 1.2 1.1 2.0 7.4 10.4 9.8 6.2 1.6 0.9 1.7 4.4 10.7
4.5
1.5
2.6
2.9
9.1
9.7
1.27.27.16.5
4.1
4.5
3.7
3.4
3.7
1.0
2.5
2.5
2.8
3.6
1.2 8.9 6.0 5.6
1.6
2.9
3.1
3.6
4.6
6.5 4.2 2.4 1.5 1.2
1.1
0.8
0.6
0.4
0.4
0.3
0.5
0.9
1.4
2.0
1.7 1.4 0.9 0.6 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.6 0.9 1.3 1.8 3.1 4.4 5.2
5.2
0.7
0.5
0.8
1.6
7.0
3.30.90.40.20.20.20.20.20.20.20.30.50.9
1.4
1.7
1.2
0.8
0.6
0.8
1.2
1.7
1.3
0.8
0.6 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.7 0.9
1.5
1.5
1.0
0.7
0.7
1.1
1.8
2.7
2.9
1.0
2.0
4.1
9.3
5.23.01.81.21.1
3.4
2.4
2.1
2.5
5.1
8.8 4.4 2.7
0.8 1.0
0.9
0.8
5.8
3.1
2.5
2.7
5.1
1.00.30.3
0.8
0.2
0.7 2.4
3.74.2
2.3 1.2 1.1 2.0 7.4 10.4 9.8 6.2 1.6 0.9 1.7 4.4 10.7
4.5
1.5
2.6
2.9
9.1
9.7
1.27.27.16.5
4.1
4.5
3.7
3.4
3.7
1.0
2.5
2.5
2.8
3.6
1.2 8.9 6.0 5.6
1.6
2.9
3.1
3.6
4.6
6.5 4.2 2.4 1.5 1.2
1.1
0.8
0.6
0.4
0.4
0.3
0.5
0.9
1.4
2.0
1.7 1.4 0.9 0.6 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.6 0.9 1.3 1.8 3.1 4.4 5.2
5.2
0.7
0.5
0.8
1.6
7.0
3.30.90.40.20.20.20.20.20.20.20.30.50.9
1.4
1.7
1.2
0.8
0.6
0.8
1.2
1.7
1.3
0.8
0.6 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.7 0.9
1.5
1.5
1.0
0.7
0.7
1.1
1.8
2.7
2.9
1.0
2.0
4.1
9.3
5.23.01.81.21.1
X2
(N)XM
(N)XM
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N)XM
X2
(EXN)
(N)XM
(N)XM
(N) XM
(N)X2
(N)
X1
X2
(N) XM
CLG
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
(N)
(N)XM
(N)XME
(N)XME
(N)XME
14.1 1.9 1.1 1.1 2.8 13.2 11.1 2.6 1.3 1.1
1.2
4.4
2.2
1.8
1.7
1.9
2.2
4.0
4.2
1.6
0.9
0.9
0.8
0.8
1.3
9.1
19.7
4.0
2.51.11.11.11.12.0
3.1
2.2
7.2
3.52.52.8
1.8
2.6
1.3
0.7
0.6
0.7
1.1
3.2
3.9
4.3 1.7 1.0 1.0 1.0 1.4 3.7
19.2
12.4
4.9 2.0 3.1 16.8
14.1 1.9 1.1 1.1 2.8 13.2 11.1 2.6 1.3 1.1
1.2
4.4
2.2
1.8
1.7
1.9
2.2
4.0
4.2
1.6
0.9
0.9
0.8
0.8
1.3
9.1
19.7
4.0
2.51.11.11.11.12.0
3.1
2.2
7.2
3.52.52.8
1.8
2.6
1.3
0.7
0.6
0.7
1.1
3.2
3.9
4.3 1.7 1.0 1.0 1.0 1.4 3.7
19.2
12.4
4.9 2.0 3.1 16.8
(EXN)XM
4
4
(E)
(N) XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N)XM
(CLG)
(N) XM
(CLG)
(N)XM
(CLG)
XM
UP
UP
1
1
A
B
G
4 5 14 15 18
18
E
D
6 13
8 11
3 16791012
F
2
2
C
17
17
(E)
1
1
(E)
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
2
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
1
1
3
-
L
T
G
E
M
P
H
O
T
O
M
E
T
R
I
C
S
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 FIRST FLOOR EM PHOTOMETRIC PLAN
SCALE: 1/8"=1'-0"
L
I
G
H
T
I
N
G
E
M
E
R
G
E
N
C
Y
P
H
O
T
O
M
E
T
R
I
C
P
L
A
N
E-113
NORTH
2 SECOND FLOOR EM PHOTOMETRIC PLAN
SCALE: 1/8"=1'-0"
CBC 1008.3.5 ILLUMINATION LEVEL UNDER EMERGENCY
POWER
EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGE TO PROVIDE
INITIAL ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1
FOOT-CANDLE AND A MINIMUM AT ANY POINT0.1 FOOT-CANDLE MEASURE
ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS
SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE AVERAGE AND A
MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE AT THE END OF THE
EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM
ILLUMINATION UNIFORMITY RATION OF 40 TO 1 SHALL NOT BE EXCEEDED.
LEGEND
EMERGENCY LIGHT WITH 90 MINUTE BATTERY BACK-UP
EXIT SIGN WITH EMERGENCY LIGHT AND 90 MINUTE BATTERY BACK-UP
EXIT SIGN WITH 90 MINUTE BATTERY BACK-UP
REFERENCE NOTES
1.REFER TO 1ST FLOOR STAIRWELL FOR LIGHT LEVELS UNDER
EMERGENCY.
1
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
1
1
A A
B B
G G
4 5 14 15 18
18
E E
D D
6 13
8 11
3 16791012
F F
2
2
C C
17
17
DS
1
(ODU)
208V, 1ɸ
16.5 MCA
20 MOCP
1C-39/41
2
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
2
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
1
2
1
-
R
O
O
F
P
L
N
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
EL
E
C
T
R
I
C
A
L
R
O
O
F
P
L
A
N
E-121
REFERENCE NOTES
1.PROVIDE LINE VOLTAGE CONNECTION TO MECHANICAL UNIT.
ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION
WITH MECHANICAL PLANS AND PROVIDE 2-POLE, NEMA 3R
DISCONNECT PER MANUFACTURER'S REQUIREMENTS.
2.NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C".
PROVIDE NEW 20A/2P CIRCUIT BREAKER IN PANEL AS DESIGNATED
TO MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN
AND (1) #12 CU GROUND.
NORTH
SCALE:
POWER SIGNAL SECOND FLOOR PLAN
3/16"=1'-0"
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
2
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
2
0
1
-
E
L
E
C
D
E
T
A
I
L
S
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
3 TYPICAL DEVICE ADA MOUNTING HEIGHTS
SCALE: NTS
34
"
M
A
X
I
M
U
M
46
"
M
A
X
I
M
U
M
-
S
I
D
E
R
E
A
C
H
24" MAXIMUM
MOUNTING HEIGHT OVER OBSTRUCTION
15
"
MI
N
I
M
U
M
TO BOTTOM OF
WIRING DEVICE
OUTLET BOX
TO TOP OF SWITCH,
THERMOSTAT, OUTLET,
OR CONTROL DEVICE
TO TOP OF SWITCH,
THERMOSTAT, OUTLET,
OR CONTROL DEVICE
FINISH FLOOR FINISH FLOOR
*
N
O
F
O
R
W
A
R
D
R
E
A
C
H
A
L
L
O
W
E
D
48
"
MA
X
I
M
U
M
UN
L
E
S
S
K
N
E
E
S
P
A
C
E
I
S
P
R
O
V
I
D
E
D
*
2
7
"
C
L
R
FIXTURES LESS THAN 50 LBS
PROVIDE POSITIVE FASTENING
TO T-BAR GRID AT EACH END OF FIXTURE.
ATTACH WITH #8 FLAT HEAD SHEET METAL SCREW
T-BAR CEILING GRID,
SEE ARCHITECTURAL
REFLECTED CEILING
PLANS.
LIGHTING FIXTURE PER
FIXTURE SCHEDULES.
REFER TO ARCHITECTURAL
DETAILS FOR ATTACHMENT TO
STRUCTURE.
CEILING SUPPORT
WIRES.
MINIMUM (3) TIGHT TURNS
IN 1-1/2".
HEAVY DUTY GRID SYSTEM
PROVIDE #12 GA. SLACK SUPPORT WIRES AT 2
DIAGONALLY OPPOSITE CORNERS FOR FIXTURES
UP TO 50 LBS. (FIXTURES ABOVE 50 LBS. SHALL BE
INDEPENDENTLY SUPPORTED AS NOTED BELOW).
AT STUD WALL
AT CMU WALL
REFERENCE NOTES
HEIGHT
SEE ARCH. PLANS
FOR MOUNTING
OUTLET BOX
PROVIDE #10x1" HEX HEAD
SELF-TAPPING SCREWS AT FIXTURE
MOUNTING POINTS. (MINIMUM OF 2)
TO BACKING OR WALL
STUDS
METAL WALL STUD,
SEE ARCH. PLANS.
WALL FINISH, SEE
ARCH. PLANS.
WALL STUD BACKING
PER 14-X/S105.
1.SMALL SURFACE MOUNTED LIGHT
FIXTURE. (20 LBS. OR LESS)
2.CONCRETE MASONRY WALL.
3.3/8" DIA. HILTI KB3 , PER ICC ESR-2302.
PROVIDE MINIMUM 2-1/2" EMBEDMENT.
NOTE:
FLUSH MOUNTED OUTLET BOX IS NOT
SHOWN FOR CLARIFICATION.
LIGHTING FIXTURE
PER FIXTURE
SCHEDULE ON
SHEET X/E105.
PLAN
PLAN
FIRE PUTTY IS NOT REQUIRED IF
ONLY ONE BOX IS INSTALLED ON
EITHER SIDE OF 100 SF OF WALL.
2
1
3
WRAP FIRE PUTTY PADS
OVER FITTING
WRAP FIRESTOP PUTTY
PADS OVER ENTIRE BOX.
OVERLAP ON TOP, BOTTOM
& SIDES.
OUTLET BOX. REFER TO
PLANS AND SPECIFICATION
FOR TYPE, SIZE & QUANTITY.
PROVIDE 1/4" BEAD OF
INSULATING PUTTY TO SEAL
BETWEEN PLASTER RING &
DRYWALL
FILL GAP BETWEEN
PLASTER RING AND
DRYWALL WITH PLASTER
PLASTER RING. REFER TO
ARCHITECTURAL PLANS FOR
WALL TYPE AND PROVIDE
RING DEPTH TO MATCH
DRYWALL DEPTH
FLUSH MOUNTED
J-BOX
FINISH WALL
6 DEVICE INSTALLATION - RATED WALLS
SCALE: NTS
5 LAY-IN BAR FIXTURE MOUNTING DETAIL
SCALE: NTS
4 SURFACE MOUNT FIXTURE DETAIL
SCALE: NTS
9 IMAGE AT ROOM 202
8 IMAGE AT ROOM 214
7 IMAGE AT ROOM 123
12 TYPICAL MODULAR FUNITURE FEED DETAIL
10 IMAGE AT OPEN OFFICE FLOOR
LIQUID-TIGHT FLEXIBLE CONDUIT
90° CONDUIT CONNECTOR-REVERSIBLE
(PROTRUDES WIDTH OF CONDUIT)
CONNECTION DISTRIBUTION
HARNESS
INSET
BUILDING WALL TO PANEL BASE
LIQUID-TIGHT FLEXIBLE CONDUIT
PARTITION CONNECTION, SEE INSET
IF NOT PRE-PUNCHED, USE HOLE
SAW OR PUNCH TO MAKE HOLE
FOR FLEX FITTING. INSTALL
CABLES INTO FURNITURE CABLE
CHANNEL.
FLUSH, WALL MOUNTED
POWER FEED J-BOX
WITH EXTENSION BOX.
SEE PLAN FOR NUMBER
OF CIRCUITS.
FLUSH, WALL MOUNTED
COMMUNICATIONS FEED
J-BOX WITH EXTENSION
BOX. SEE
COMMUNICATIONS PLAN
FOR NUMBER OF CABLES.
CARLON FLEX CONDUIT,
SAME SIZE AS RACEWAY IN
WALL, WITH
COMMUNICATIONS CABLE.
RECEPTACLE LOCATIONS
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
E-201
EXISTING 14-CAT6 CABLES. REMOVED CABLES AND DISCONNECT AT "MDF" IN ELECTRICAL
ROOM. DO NOT CUT CABLES.
11
1 SCALE: NTS
2
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.
THOMA ELECTRIC, INC.
Phone: (805) 543-3850
cad@thomaelec.com
Fax: (805) 543-3829
S
e
p
1
3
,
2
0
2
4
-
1
2
:
4
2
p
m
-
C
h
r
i
s
-
K
:
\
E
N
G
\
2
0
2
4
\
2
4
-
8
0
2
6
\
2
4
-
8
0
2
6
_
E
-
3
0
1
-
T
2
4
F
O
R
M
S
.
d
w
g
2000577-04
11
0
6
W
A
L
N
U
T
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
TI
T
L
E
2
4
E
N
E
R
G
Y
F
O
R
M
S
-
I
N
T
E
R
I
O
R
L
I
G
H
T
I
N
G
E-301
ERE
TYM.E
C
F
NO. 20823
EL
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
LERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L
ERE
TYM.E
C
F
NO. 20823
E
L
T
S
OE
A
T
E
SIGER
EJ
FTF RE
A
RO
L
I CRT
IL FCA
AIN
H
O
M N
A
RE
E
G
I
N
ORPD NA
OIEFSS
L