HomeMy WebLinkAboutItem 6d. Attachment B - 1166 Walnut TI Plans (Spec. 2000577-04)_High Resolution PlansPROJECT SITE H I G H W A Y 1 0 1 S A N T A R O S A S T W A L N U T S T 1 NORTH ARROW LEVEL DESIGNATION GRID REFERENCE SECTION REFERENCE VIEW SHEET LOCATION REFERENCE SHEET LOCATION VIEW NUMBER VIEW TITLE LEVEL ELEVATION BUILDING LEVELS DETAIL REFERENCE Name 0' - 0" A101 1 SIM A101 1 SIM BUILDING ELEVATION A101 1 SIM A101 1 2 3 4 INTERIOR ELEVATIONS DOOR W/CLOSER DOOR TAG WINDOW TAG STOREFRONT TAG WALL TAG CENTERLINEREVISION TAG A4 1i 01 101 View Name SCALE: 1/8" = 1'-0"A-101 A-202 20 0 ?P1 MATERIAL TAG PROJECT DIRECTORY PROJECT INFORMATION VICINITY MAP USE OF PLANS:THESE PLANS ARE THE PROPERTY OF RRM AND MAY NOT BE USED WITHOUT THE EXPRESS, WRITTEN CONSENT. THESE NOTES APPLY TO ALL PORTIONS, PHASES AND SUBCONTRACTORS OF THIS PROJECT. APPLICABLE CODES AND STANDARDS: • 2022 CALIFORNIA BUILDING CODE AND ITS APPENDICES AND STANDARDS. • 2022 CALIFORNIA PLUMBING CODE AND ITS APPENDICES AND STANDARDS. • 2022 CALIFORNIA MECHANICAL CODE AND ITS APPENDICES AND STANDARDS. • 2022 CALIFORNIA FIRE CODE AND ITS APPENDICES AND STANDARDS. • 2022 CALIFORNIA ELECTRICAL CODE AND ITS APPENDICES AND STANDARDS. • 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS. • 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE AND ITS APPENDICIES AND STANDARDS. • CURRENT CITY OF SAN LUIS OBISPO MUNICIPAL CODE. 1. ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY WITH EXISTING SITE CONDITIONS. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ARCHITECT’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO, HE/SHE SHALL BE PRECEDING AT HIS/HER OWN RISK. 2. DIMENSIONS SHOWN SHALL TAKE PRECEDENCE OVER DRAWING SCALE OR PROPORTION. LARGER SCALE DRAWINGS SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. ALL DIMENSIONS ARE ROUGH AND TO FACE OF FRAMING. 3. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES. 4. CONTRACTOR IS TO BE RESPONSIBLE FOR BEING FAMILIAR WITH THESE DOCUMENTS INCLUDING ALL CONTRACT REQUIREMENTS. 5. CONTRACTOR TO REVIEW CALIFORNIA GREEN CODE REQUIREMENTS FOR CONTRACTOR REQUIREMENTS. 6. TEMPORARY FACILITIES: CONTRACTOR SHALL PAY FOR, PROVIDE AND MAINTAIN TEMPORARY FACILITIES FOR PROJECT PROTECTION AND CONSTRUCTION, AND AS REQUIRED BY LOCAL REGULATION AND THESE DOCUMENTS. SUCH FACILITIES INCLUDE, BUT ARE NOT LIMITED TO: TOILETS, LIGHTS, HEATERS, POWER, GAS, FANS, WATER, PHONES, FENCES, SIGNS, SHEDS, ETC. REMOVE FROM SITE UPON COMPLETION OF WORK. OBTAIN BUILDING OFFICIAL OR FIRE MARTIAL APPROVAL PRIOR TO USE OF ANY TEMPORARY HEATING DEVICE. 7. CONTRACTOR SHALL PROVIDE FOR PROTECTION AND SAFETY: RESPONSIBLE FOR ALL ITEMS (SIGNS, LIGHTS, FENCES, BRACING, ANCHOR- AGE, FIRE-EXTINGUISHERS, ETC.) NECESSARY FOR THE PROTECTION OF THE PUBLIC, WORKERS, MATERIALS, CONSTRUCTION AND PROPERTY PER LOCAL, STATE AND FEDERAL REQUIREMENTS (INCLUDING EARTHQUAKES, FIRES, SPILLS, ACCIDENTS, EROSION, MUD, DUST, ETC.). PROJECT GENERAL NOTES PROJECT SCOPE: 1. 2. SELECTIVE DEMOLITION OF PARTITIONS, CEILINGS, FINISHES, MECHANICAL EQUIPMENT, ELECTRICAL DEVICES. CONSTRUCTION OF NEW PARTITIONS, CEILINGS, FINISHES, MECHANICAL EQUIPMENT, ELECTRICAL DEVICES, INTERIOR STOREFRONT WINDOWS. BUILDING INFORMATION: OCCUPANCY: B, A-3 CONSTRUCTION TYPE: VB FIRE SPRINKLERED: YES BUILDING HEIGHT: 35' NUMBER OF STORIES: 2 TOTAL BUILDING AREA: 10,921 SF FIRST FLOOR BUILDING AREA: 5,586 SF SECOND FLOOR BUILDING AREA: 5,335 SF SEE SHEET G-401 FOR CODE ANALYSIS SITE INFORMATION: APN: STREET ADDRESS: ZONING: LOT SIZE: LAND USE: EXISTING USE: PROPOSED USE: 1106 WALNUT ST. SAN LUIS OBISPO, CA. 001-207-039 O (OFFICE) OFFICE OFFICE 0.87 AC OFFICE ADDRESS: CONTACT: EMAIL: CITY OF SAN LUIS OBISPO 919 PALM ST. SAN LUIS OBISPO, CA. 93401 OWNER SANDRA GOLONKA SGOLONKA@SLOCITY.ORG ADDRESS: CONTACT: EMAIL: RRM DESIGN GROUP 3765 S. HIGUERA ST. SUITE 102 SAN LUIS OBISPO, CA. 93401 ARCHITECT JON HOUCK JHOUCK@RRMDESIGN.COM ADDRESS: CONTACT: EMAIL: 3C ENGINEERING 1500 PALM ST. SAN LUIS OBISPO, CA. 93401 MECHANICAL ENGINEER DENVER STANGER DSTANGER@3CENG.COM ADDRESS: CONTACT: EMAIL: THOMA ELECTRIC 3562 EMPLEO ST. SAN LUIS OBISPO, CA. 93401 ELECTRICAL ENGINEER CHRIS JOSE CJOSE@THOMAELEC.COM HC HOLLOW CORE HDWD HARDWOOD HDWR HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING, VENTILATION, A/C ID INSIDE DIAMETER IIC IMPACT INSULATION CLASS IN INCH INCAND INCANDESCENT INSUL INSULATION, INSULATED INT INTERIOR JC JANITORS CLOSET JT JOINT LAM LAMINATE LAV LAVATORY LBS POUNDS LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN LF LINEAR FEET LIN LINEN CLOSET LINO LINOLEUM LT(G) LIGHT(ING) LVL LAMINATED VENEER LUMBER LVT LUXURY VINYL TILE LW LIGHTWEIGHT MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MECH MECHANICAL MEMB MEMBRANE MEP MECHANICAL, ELECTRICAL, PLUMBING MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTD MOUNTED MTL METAL N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE O.P. OVERFLOW PIPE OC ON CENTER OD OVERFLOW DRAIN OFF OFFICE OH OPPOSITE HAND OPG OPENING OPP OPPOSITE (P) PROPOSED PERM PERIMETER PERP PERPENDICULAR PG PAINT GRADE PL PLATE, PROPERTY LINE PLAM PLASTIC LAMINATE PLBG PLUMBING PLYWD PLYWOOD PNL PANEL PP POWER POLE PR PAIR PRTN PARTITION PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED PTD PAINTED PV PHOTO VOLTAIC PVC POLYVINYL CHLORIDE PVMT PAVEMENT QTY QUANTITY R RADIUS, RISER RB RUBBER BASE RCP REFLECTED CEILING PLAN RD ROOF DRAIN REF REFRIGERATOR REINF REINFORCED REQD REQUIRED RH RIGHT HAND RM ROOM RO ROUGH OPENING RTU ROOF TOP UNIT (MECH) S SOUTH SAFB SOUND ATTENUATION FIBER BATT SAWP SELF ADHEREING WATERPROOFING SC SCUPPER/SOLID CORE SCHED SCHEDULE SEAL SEALANT SECT SECTION SF SQUARE FOOT SHT SHEET SHTHG SHEATHING SIM SIMILAR SM SHEET METAL SPEC SPECIFICATION SQ SQURE SS SOLID SURFACE SSTL STAINLESS STEEL STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUPSPENDED SV SHEET VINYL SYM SYMMMETRICAL T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPERED TER TERRAZZO THK THICK THR THRESHOLD TJI TRUSS JOIST I-JOIST TO TOP OF TOS TOP OF SLAB TOW TOP OF WALL TRANS TRANSFORMER TV TELEVISION TYP TYPICAL UFAS UNIFORM FEDERAL ACCESSIBILITY STANDARDS UG UNDERGROUND UNFIN UNFINISHED UNO ULNESS NOTED OTHERWISE UV UTRAVIOLET VCT VINYL COMPOSITION TILE VERT VERTICAL VIF VERIFY IN FIELD VTR VENT TERMINATION PIPE VWC VINYL WALL COVERING W WEST W/ WITH W/D WASHER DRYER W/O WITHOUT WC WATERCLOSET WD WOOD WDW WINDOW WH WATER HEATER WI WROUGHT IRON WIN WINDOW WP WATERPROOF(ING) WR WEATHER RESISTIVE WRB WATER RESISTIVE BARRIER WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC YD YARD ABBREVIATIONS SYMBOLS A/C AIR CONDITIONING ABV ABOVE ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE ADA AMERICANS WITH DISABILITIES ACT AFCI ARC FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISH FLOOR AL ALUMINUM ALT ALTERNATE ARCH ARCHITECT(URAL) BD BOARD BDRM BEDROOM BET BETWEEN BIT BITUMINOUS BLDG BUILDNG BLKG BLOCKING BLW BELOW BM BEAM BOT BOTTOM BUR BUILT UP ROOF CB CATCH BASIN CBC CALIFORNIA BUILDING CODE CEM CEMENT CFM CUBIC FEET PER MINUTE CIP CAST IN PLACE CJ CONTROL JOINT CL CENTER LINE CLG CEILING CLO CLOSET CLR CLEAR CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CPT CARPET CT CERAMIC TILE CTR CENTER DBL DOUBLE DF DRINKING FOUNTAIN DIA DIAMETER, DIAPHRAGM DIM DIMENSION DN DOWN DR DOOR DS DOWN SPOUT DTL DETAIL DW DISHWASHER DWG DRAWING (E) EXISTING E EAST EA EACH EJ EXPANSION JOINT EL, ELEV ELEVATION ELEC ELECTRIC ENCL ENCLOSURE EQ EQUAL EQUIP EQUIPMENT EXH EXHAUST EXP EXPANSION EXT EXTERIOR FACP FIRE ALARM CONTROL PANEL FAU FORCED AIR UNIT FAWP FLUID APPLIED WATERPROOFING FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR ELEVATION FG FINISHED GRADE FH FIRE HYDRANT FHC FIRE HOSE CABINET FIN FINISH FIXT FIXTURE FLR FLOOR FLUOR FLOURESCENT FND FOUNDATION FO FACE OF FOC FACE OF CONCRETE FOF FACE OF FINISH FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FOM FACE OF MASONRY FOS FACE OF STUD FRP FIBERGLASS REINFORCED PANELS FT FOOT OR FEET FTG FOOTING GA GAUGE, GAGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GWB GYPSUM BOARD GYP GYPSUM HB HOSE BIBB GENERAL G-001 TITLE SHEET G-203 CAL GREEN REQUIREMENTS G-204 CAL GREEN REQUIREMENTS G-205 CAL GREEN REQUIREMENTS G-401 CODE ANALYSIS G-902 ACCESSIBILITY DETAILS G-903 ACCESSIBILITY DETAILS G-904 ACCESSIBILITY DETAILS 8 ARCHITECTURAL SITE AS-101 ARCHITECTURAL SITE PLAN 1 ARCHITECTURAL AD-101 DEMOLITION FIRST FLOOR PLAN AD-102 DEMOLITION SECOND FLOOR PLAN AD-111 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR AD-112 DEMOLITION REFLECTED CEILING PLAN - SECOND FLOOR A-101 PROPOSED FIRST FLOOR PLAN A-102 PROPOSED SECOND FLOOR PLAN A-111 REFLECTED CEILING PLAN - FIRST FLOOR A-112 REFLECTED CEILING PLAN - SECOND FLOOR A-120 ROOF PLAN A-200 EXTERIOR ELEVATIONS A-401 ENLARGED FLOOR PLANS A-411 INTERIOR ELEVATIONS A-412 INTERIOR ELEVATIONS A-413 INTERIOR ELEVATIONS A-501 FIRST FLOOR FINISH PLAN A-502 SECOND FLOOR FINISH PLAN A-503 FIRST FLOOR FURNITURE PLAN A-504 SECOND FLOOR FURNITURE PLAN A-601 DOOR AND WINDOW SCHEDULES A-901 DOOR & WINDOW DETAILS A-902 DETAILS A-903 DETAILS A-904 DETAILS 23 MECHANICAL & PLUMBING MP-000 MECHANICAL & PLUMBING GENERAL NOTES MP-001 MECHANICAL & PLUMBING SCHEDULES MP-002 MECHANICAL AND PLUMBING DETAILS EC-000 ENERGY COMPLIANCE DOCUMENTATION MPD-101 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN MPD-102 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN MP-200 MECHANICAL & PLUMBING FIRST FLOOR PLAN MP-300 MECHANICAL & PLUMBING SECOND FLOOR PLAN 8 ELECTRICAL E-001 ELECTRICAL GENERAL NOTES E-002 ELECTRICAL LEGEND AND ABBREVIATIONS E-003 ELECTRICAL SINGLE LINE DIAGRAM AND SCHEDULES ED-101 FIRST FLOOR POWER SIGNAL DEMOLITION FIRST FLOOR PLAN ED-102 SECOND FLOOR POWER SIGNAL DEMOLITION PLAN E-101 FIRST FLOOR POWER AND SIGNAL PLAN E-102 SECOND FLOOR POWER AND SIGNAL PLAN E-111 FIRST FLOOR LIGHTING PLAN E-112 SECOND FLOOR LIGHTING PLAN E-113 LIGHTING EMERGENCY PHOTOMETRIC PLANS E-121 ELECTRICAL ROOF PLAN E-201 ELECTRICAL DETAILS E-301 TITLE 24 ENERGY FORMS - INTERIOR LIGHTING 13 Grand total: 53 1 1. FIRE SPRINKLER MODIFICATIONS DUE TO ADDING / MOVING WALLS DEFERRED SUBMITTALS1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH No. C 79870 B R I A N A .NEL S O N C I V I L R E GISTERE D P R OFESSIO N A LE N G I N E ER S TAT EOFCA L I F O RNIA 1106 WALNUT TENANT IMPROVEMENT sheet no.description SAN LUIS OBISPO COUNTY, CALIFORNIA APPROVED BY SPECIFICATION NO.DATE SHEET Brian A. Nelson, City Engineer R.C.E. C79870 Approved Date FILE NO./LOCATION index to plans 2000577-04 09/12/2024 G-001 9/13/24 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 CA L G R E E N R E Q U I R E M E N T S G-203 JH JR 6/20/24 JR ALLOWABLE RATING TABLE 5.106.8 [N] - MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT AND GLARE (BUG) RATING1, 2 LUMINAIRE GREATER THAN 2 MOUNTING HEIGHTS (MH) FROM PROPERTY LINE MAXIMUM ALLOWABLE BACKLIGHT RATING3 (B) LIGHTING ZONE LZ4 NO LIMIT LUMINAIRE BACK HEMISPHERE IS 1-2 MH FROM PROPERTY LINE LUMINAIRE BACK HEMISPHERE IS 0.5-1 MH FROM PROPERTY LINE LUMINAIRE BACK HEMISPHERE IS LESS THAN 0.5 MH FROM PROPERTY LINE NO LIMITNO LIMITNO LIMITN/A FOR AREA LIGHTING3 MAXIMUM ALLOWABLE UPLIGHT RATING (U) FOR ALL OTHER OUTDOOR LIGHTING, INCLUDING DECORATIVE LUMINAIRES MAXIMUM ALLOWABLE GLARE RATING (G) LUMINAIRE GREATER THAN 2 MOUNTING HEIGHTS (MH) FROM PROPERTY LINE LUMINAIRE FRONT HEMISPHERE IS 1-2 MH FROM PROPERTY LINE LIGHTING ZONE LZ3 LIGHTING ZONE LZ2 LIGHTING ZONE LZ1 LIGHTING ZONE LZ0 B4B4B3B2N/A B3B3B2B1N/A B2B1B0B0N/A U0U0U0U0N/A U4U3U2U1N/A G4G3G2G1N/A G2G1G1G0N/A LUMINAIRE FRONT HEMISPHERE IS 0.5-1 MH FROM PROPERTY LINE LUMINAIRE FRONT HEMISPHERE IS LESS THAN 0.5 MH FROM PROPERTY LINE G1G1G0G0N/A G1G0G0G0N/A TOTAL NUMBER OF ACTUAL PARKING SPACES TABLE 5.106.5.3.1 0-9 10-25 26-50 51-75 76-100 101-150 NUMBER OF EVCS (EV CAPABLE SPACES PROVIDED WITH EVSE) 2 151-200 201 AND OVER NUMBER OF REQUIRED EV CAPABLE SPACES 0 4 8 13 17 25 35 20% OF TOTAL 1 0 0 2 3 4 6 6 25% OF EV CAPABLE SPACES 1 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 1 (JANUARY 2023) DIVISION 5.1 PLANNING AND DESIGN 5.106 SITE DEVELOPMENT 5.106.1 STORMWATER POLLUTION FOR PROJECTS THAT DISTURB LESS THAN ONE ACRE OF LAND NEWLY CONSTRUCTED PROJECTS AND ADDITIONS WHICH DISTURB LESS THAN ONE ACRE OF LAND AND ARE NOT PART OF A LARGER COMMON PLAN OF DEVELOPMENT OR SALE SHALL PREVENT THE POLLUTION OF STORMWATER RUNOFF FROM THE CONSTRUCTION ACTIVITIES THROUGH ONE OR MORE OF THE FOLLOWING MEASURES: 5.106.1.1 LOCAL ORDINANCE COMPLY WITH A LAWFULLY ENACTED STORMWATER MANAGEMENT AND/OR EROSION CONTROL ORDINANCE. 5.106.1.2 BEST MANAGEMENT PRACTICES (BMP’S) PREVENT THE LOSS OF SOIL THROUGH WIND OR WATER EROSION BY IMPLEMENTING AN EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROL AND GOOD HOUSEKEEPING BMP’S. 1. SOIL LOSS BMP’S THAT SHOULD BE CONSIDERED FOR IMPLEMENTATION AS APPROPRIATE FOR EACH PROJECT INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: a. SCHEDULING CONSTRUCTION ACTIVITY DURING DRY WEATHER, WHEN POSSIBLE. b. PRESERVATION OF NATURAL FEATURES, VEGETATION, SOIL AND BUFFERS AROUND SURFACE WATERS. c. DRAINAGE SWALES OR LINED DITCHES TO CONTROL STORMWATER FLOW. d. MULCHING OR HYDROSEEDING TO STABILIZE DISTURBED SOILS. e. EROSION CONTROL TO PROTECT SLOPES. f. PROTECTION OF STORM DRAIN INLETS (GRAVEL BAGS OR CATCH BASIN INSERTS). g. PERIMETER SEDIMENT CONTROL (PERIMETER SILT FENCE, FIBER ROLLS). h. SEDIMENT TRAP OR SEDIMENT BASIN TO RETAIN SEDIMENT ON SITE. i. STABILIZED CONSTRUCTION EXITS. j. WIND EROSION CONTROL. k. OTHER SOIL LOSS BMP'S ACCEPTABLE TO THE ENFORCING AGENCY. 2.GOOD HOUSEKEEPING BMP’S TO MANAGE CONSTRUCTION EQUIPMENT, MATERIALS, NON-STORMWATER DISCHARGES, AND WASTES THAT SHOULD BE CONSIDERED FOR IMPLEMENTATION AS APPROPRIATE FOR EACH PROJECT INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: a. DEWATERING ACTIVITIES. b. MATERIAL HANDLING AND WASTE MANAGEMENT. c. BUILDING MATERIALS STOCKPILE MANAGEMENT. d. MANAGEMENT OF WASHOUT AREAS (CONCRETE, PAINTS, STUCCO, ETC.). e. CONTROL OF VEHICLE/EQUIPMENT FUELING TO CONTRACTOR'S STAGING AREA. f. VEHICLE AND EQUIPMENT CLEANING PERFORMED OFF SITE. g. SPILL PREVENTION AND CONTROL. h. OTHER HOUSEKEEPING BMP'S ACCEPTABLE TO THE ENFORCING AGENCY. 5.106.4 BICYCLE PARKING FOR BUILDINGS WITHIN THE AUTHORITY OF CALIFORNIA BUILDING STANDARDS COMMISSION AS SPECIFIED IN SECTION 103, COMPLY WITH SECTION 5.106.4.1. FOR BUILDINGS WITHIN THE AUTHORITY OF THE DIVISION OF THE STATE ARCHITECT PURSUANT TO SECTION 105, COMPLY WITH SECTION 5.106.4.2. 5.106.4.1 BICYCLE PARKING [BSC-CG] COMPLY WITH SECTIONS 5.106.4.1.1 AND 5.106.4.1.2;OR MEET THE APPLICABLE LOCAL ORDINANCE, WHICHEVER IS STRICTER. 5.106.4.1.1 SHORT-TERM BICYCLE PARKING IF THE NEW PROJECT OR AN ADDITION OR ALTERATION IS ANTICIPATED TO GENERATE VISITOR TRAFFIC, PROVIDE PERMANENTLY ANCHORED BICYCLE RACKS WITHIN 200 FEET OF THE VISITORS' ENTRANCE, READILY VISIBLE TO PASSERS-BY, FOR 5 PERCENT OF NEW VISITOR MOTORIZED VEHICLE PARKING SPACES BEING ADDED, WITH A MINIMUM OF ONE TWO-BIKE CAPACITY RACK. 1 CALCULATION FOR SPACES SHALL BE ROUNDED UP TO THE NEAREST WHOLE NUMBER. CHAPTER 1 - ADMINISTRATION SECTION 101 GENERAL 101.1 TITLE. THESE REGULATIONS SHALL BE KNOWN AS THE CALIFORNIA GREEN BUILDING STANDARDS CODE AND MAY BE CITED AS SUCH AND WILL BE REFERRED TO HEREIN AS “THIS CODE.”IT IS INTENDED THAT IT SHALL ALSO BE KNOWN AS THE CALGREEN CODE. THE CALIFORNIA GREEN BUILDING STANDARDS CODE IS PART 11 OF THIRTEEN PARTS OF THE OFFICIAL COMPILATION AND PUBLICATION OF THE ADOPTION, AMENDMENT AND REPEAL OF BUILDING REGULATIONS TO THE CALIFORNIA CODE OF REGULATIONS, TITLE 24, ALSO REFERRED TO AS THE CALIFORNIA BUILDING STANDARDS CODE. 101.2 PURPOSE. THE PURPOSE OF THIS CODE IS TO IMPROVE PUBLIC HEALTH, SAFETY AND GENERAL WELFARE BY ENHANCING THE DESIGN AND CONSTRUCTION OF BUILDINGS THROUGH THE USE OF BUILDING CONCEPTS HAVING A REDUCED NEGATIVE IMPACT OR POSITIVE ENVIRONMENTAL IMPACT AND ENCOURAGING SUSTAINABLE CONSTRUCTION PRACTICES IN THE FOLLOWING CATEGORIES: 1. PLANNING AND DESIGN. 2. ENERGY EFFICIENCY. 3. WATER EFFICIENCY AND CONSERVATION. 4. MATERIAL CONSERVATION AND RESOURCE EFFICIENCY. 5. ENVIRONMENTAL QUALITY. 101.3 SCOPE. THE PROVISIONS OF THIS CODE SHALL APPLY TO THE PLANNING, DESIGN, OPERATION, CONSTRUCTION, USE AND OCCUPANCY OF EVERY NEWLY CONSTRUCTED BUILDING OR STRUCTURE, UNLESS OTHERWISE INDICATED IN THIS CODE, THROUGHOUT THE STATE OF CALIFORNIA. IT IS NOT THE INTENT THAT THIS CODE SUBSTITUTE OR BE IDENTIFIED AS MEETING THE CERTIFICATION REQUIREMENTS OF ANY GREEN BUILDING PROGRAM. SECTION 301 GENERAL 301.1 SCOPE. BUILDINGS SHALL BE DESIGNED TO INCLUDE THE GREEN BUILDING MEASURES SPECIFIED AS MANDATORY IN THE APPLICATION CHECKLISTS CONTAINED IN THIS CODE. VOLUNTARY GREEN BUILDING MEASURES ARE ALSO INCLUDED IN THE APPLICATION CHECKLISTS AND MAY BE INCLUDED IN THE DESIGN AND CONSTRUCTION OF STRUCTURES COVERED BY THIS CODE, BUT ARE NOT REQUIRED UNLESS ADOPTED BY A CITY, COUNTY, OR CITY AND COUNTY AS SPECIFIED IN SECTION 101.7. 301.3 NONRESIDENTIAL ADDITIONS AND ALTERATIONS [BSC-CG]THE PROVISIONS OF INDIVIDUAL SECTIONS OF CHAPTER 5 APPLY TO NEWLY CONSTRUCTED BUILDINGS, BUILDING ADDITIONS OF 1,000 SQUARE FEET OR GREATER, AND/OR BUILDING ALTERATIONS WITH A PERMIT VALUATION OF $200,000 OR ABOVE (FOR OCCUPANCIES WITHIN THE AUTHORITY OF CALIFORNIA BUILDING STANDARDS COMMISSION). CODE SECTIONS RELEVANT TO ADDITIONS AND ALTERATIONS SHALL ONLY APPLY TO THE PORTIONS OF THE BUILDING BEING ADDED OR ALTERED WITHIN THE SCOPE OF THE PERMITTED WORK. A CODE SECTION WILL BE DESIGNATED BY A BANNER TO INDICATE WHERE THE CODE SECTION ONLY APPLIES TO NEWLY CONSTRUCTED BUILDINGS [N] OR TO ADDITIONS AND/OR ALTERATIONS [A]. WHEN THE CODE SECTION APPLIES TO BOTH, NO BANNER WILL BE USED. 301.3.1 NONRESIDENTIAL ADDITIONS AND ALTERATIONS THAT CAUSE UPDATES TO PLUMBING FIXTURES ONLY: NOTE: ON AND AFTER JANUARY 1, 2014, CERTAIN COMMERCIAL REAL PROPERTY, AS DEFINED IN CIVIL CODE SECTION 1101.3, SHALL HAVE ITS NONCOMPLIANT PLUMBING FIXTURES REPLACED WITH APPROPRIATE WATER-CONSERVING PLUMBING FIXTURES UNDER SPECIFIC CIRCUMSTANCES. SEE CIVIL CODE SECTION 1101.1 ET SEQ.FOR DEFINITIONS, TYPES OF COMMERCIAL REAL PROPERTY AFFECTED, EFFECTIVE DATES, CIRCUMSTANCES NECESSITATING REPLACEMENT OF NONCOMPLIANT PLUMBING FIXTURES, AND DUTIES AND RESPONSIBILITIES FOR ENSURING COMPLIANCE. 301.3.2 WASTE DIVERSION THE REQUIREMENTS OF SECTION 5.408 SHALL BE REQUIRED FOR ADDITIONS AND ALTERATIONS WHENEVER A PERMIT IS REQUIRED FOR WORK. 301.4 PUBLIC SCHOOLS AND COMMUNITY COLLEGES (SEE GBSC) 301.5 HEALTH FACILITIES (SEE GBSC) SECTION 102 CONSTRUCTION DOCUMENTS AND INSTALLATION VERIFICATION 102.1 SUBMITTAL DOCUMENTS. CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL BE SUBMITTED IN ONE OR MORE SETS WITH EACH APPLICATION FOR A PERMIT. WHERE SPECIAL CONDITIONS EXIST, THE ENFORCING AGENCY IS AUTHORIZED TO REQUIRE ADDITIONAL CONSTRUCTION DOCUMENTS TO BE PREPARED BY A LICENSED DESIGN PROFESSIONAL AND MAY BE SUBMITTED SEPARATELY. EXCEPTION:THE ENFORCING AGENCY IS AUTHORIZED TO WAIVE THE SUBMISSION OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT REQUIRED TO BE PREPARED BY A LICENSED DESIGN PROFESSIONAL. 102.2 INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND SCOPE OF THE PROPOSED GREEN BUILDING FEATURE AND SHOW THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE, THE CALIFORNIA BUILDING STANDARDS CODE AND OTHER RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS AS DETERMINED BY THE ENFORCING AGENCY. 102.3 VERIFICATION. DOCUMENTATION OF CONFORMANCE FOR APPLICABLE GREEN BUILDING MEASURES SHALL BE PROVIDED TO THE ENFORCING AGENCY. ALTERNATE METHODS OF DOCUMENTATION SHALL BE ACCEPTABLE WHEN THE ENFORCING AGENCY FINDS THAT THE PROPOSED ALTERNATE DOCUMENTATION IS SATISFACTORY TO DEMONSTRATE SUBSTANTIAL CONFORMANCE WITH THE INTENT OF THE PROPOSED GREEN BUILDING MEASURE. CHAPTER 3 - GREEN BUILDING CHAPTER 5 - NONRESIDENTIAL MANDATORY MEASURES 5.106.5.3.2 ELECTRIC VEHICLE CHARGING STATIONS (EVCS) EV CAPABLE SPACES SHALL BE PROVIDED WITH EVSE TO CREATE EVCS IN THE NUMBER INDICATED IN TABLE 5.106.5.3.1. THE EVCS REQUIRED BY TABLE 5.106.5.3.1 MAY BE PROVIDED WITH EVSE IN ANY COMBINATION OF LEVEL 2 AND DIRECT CURRENT FAST CHARGING (DCFC), EXCEPT THAT AT LEAST ONE LEVEL 2 EVSE SHALL BE PROVIDED. ONE EV CHARGER WITH MULTIPLE CONNECTORS CAPABLE OF CHARGING MULTIPLE EVS SIMULTANEOUSLY SHALL BE PERMITTED IF THE ELECTRICAL LOAD CAPACITY REQUIRED BY SECTION 5.106.5.3.1 FOR EACH EV CAPABLE SPACE IS ACCUMULATIVELY SUPPLIED TO THE EV CHARGER. THE INSTALLATION OF EACH DCFC EVSE SHALL BE PERMITTED TO REDUCE THE MINIMUM NUMBER OF REQUIRED EV CAPABLE SPACES WITHOUT EVSE BY FIVE AND REDUCE PROPORTIONALLY THE REQUIRED ELECTRICAL LOAD CAPACITY TO THE SERVICE PANEL OR SUBPANEL. 5.106.5.3.3 USE OF AUTOMATIC LOAD MANAGEMENT SYSTEMS (ALMS) ALMS SHALL BE PERMITTED FOR EVCS. WHEN ALMS IS INSTALLED, THE REQUIRED ELECTRICAL LOAD CAPACITY SPECIFIED IN SECTION 5.106.5.3.1 FOR EACH EVCS MAY BE REDUCED WHEN SERVICED BY AN EVSE CONTROLLED BY AN ALMS. EACH EVSE CONTROLLED BY AN ALMS SHALL DELIVER A MINIMUM 30 AMPERES TO AN EV WHEN CHARGING ONE VEHICLE AND SHALL DELIVER A MINIMUM 3.3 KW WHILE SIMULTANEOUSLY CHARGING MULTIPLE EVS. 5.106.5.3.4 ACCESSIBLE EVCS WHEN EVSE IS INSTALLED, ACCESSIBLE EVCS SHALL BE PROVIDED IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE, CHAPTER 11B, SECTION 11B-228.3. NOTE: FOR EVCS SIGNS, REFER TO CALTRANS TRAFFIC OPERATIONS POLICY DIRECTIVE 13-01 (ZERO EMISSION VEHICLE SIGNS AND PAVEMENT MARKINGS) OR ITS SUCCESSOR(S). 5.106.8 LIGHT POLLUTION REDUCTION [N]. OUTDOOR LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED TO COMPLY WITH THE FOLLOWING: 1. THE MINIMUM REQUIREMENTS IN THE CALIFORNIA ENERGY CODE FOR LIGHTING ZONES 0-4 AS DEFINED IN CHAPTER 10, SECTION 10-114 OF THE CALIFORNIA ADMINISTRATIVE CODE; AND 2. BACKLIGHT (B) RATINGS AS DEFINED IN IES TM-15-11 (SHOWN IN TABLE A-1 IN CHAPTER 8); 3. UPLIGHT AND GLARE RATINGS AS DEFINED IN CALIFORNIA ENERGY CODE (SHOWN IN TABLES 130.2-A AND 130.2-B IN CHAPTER 8) AND 4. ALLOWABLE BUG RATINGS NOT EXCEEDING THOSE SHOWN IN TABLE 5.106.8 [N], OR COMPLY WITH A LOCAL ORDINANCE LAWFULLY ENACTED PURSUANT TO SECTION 101.7, WHICHEVER IS MORE STRINGENT. EXCEPTIONS: [N] 1. LUMINAIRES THAT QUALIFY AS EXCEPTIONS IN SECTION 130.2(B) AND 140.7 OF THE CALIFORNIA ENERGY CODE 2. EMERGENCY LIGHTING. 3. BUILDING FACADE MEETING THE REQUIREMENTS IN TABLE 140.7-B OF THE CALIFORNIA ENERGY CODE, PART 6. 4. CUSTOM LIGHTING FEATURES AS ALLOWED BY THE LOCAL ENFORCING AGENCY, AS PERMITTED BY SECTION 101.8 ALTERNATE MATERIALS, DESIGNS AND METHODS OF CONSTRUCTION. 5. LUMINAIRES WITH LESS THAN 6,200 INITIAL LUMINAIRE LUMENS. NOTES: [N] 1. SEE ALSO CALIFORNIA BUILDING CODE, CHAPTER 12, SECTION 1205.7 FOR COLLEGE CAMPUS LIGHTING REQUIREMENTS FOR PARKING FACILITIES AND WALKWAYS. 2. REFER TO CHAPTER 8 (COMPLIANCE FORMS, WORKSHEETS AND REFERENCE MATERIAL) FOR IES TM-15-11 TABLE A1, CALIFORNIA ENERGY CODE TABLES 130.2-A AND 130.2-B. 3. REFER TO THE CALIFORNIA ENERGY CODE FOR REQUIREMENTS FOR ADDITIONS AND ALTERATIONS. EXCEPTION:ADDITIONS OR ALTERATIONS WHICH ADD NINE OR LESS VISITOR VEHICULAR PARKING SPACES. 5.106.4.1.2 LONG-TERM BICYCLE PARKING FOR NEW BUILDINGS WITH TENANT SPACES THAT HAVE 10 OR MORE TENANT-OCCUPANTS, PROVIDE SECURE BICYCLE PARKING FOR 5 PERCENT OF THE TENANT-OCCUPANT VEHICULAR PARKING SPACES WITH A MINIMUM OF ONE BICYCLE PARKING FACILITY. 5.106.4.1.3 FOR ADDITIONS OR ALTERATIONS THAT ADD 10 OR MORE TENANT- OCCUPANT VEHICULAR PARKING SPACES, PROVIDE SECURE BICYCLE PARKING FOR 5 PERCENT OF THE TENANT VEHICULAR PARKING SPACES BEING ADDED, WITH A MINIMUM OF ONE BICYCLE PARKING FACILITY. 5.106.4.1.4 FOR NEW SHELL BUILDINGS IN PHASED PROJECTS PROVIDE SECURE BICYCLE PARKING FOR 5 PERCENT OF THE ANTICIPATED TENANT- OCCUPANT VEHICULAR PARKING SPACES WITH A MINIMUM OF ONE BICYCLE PARKING FACILITY. 5.106.4.1.5 ACCEPTABLE BICYCLE PARKING FACILITY FOR SECTIONS 5.106.4.1.2, 5.106.4.1.3, AND 5.106.4.1.4 SHALL BE CONVENIENT FROM THE STREET AND SHALL MEET ONE OF THE FOLLOWING: 1. COVERED, LOCKABLE ENCLOSURES WITH PERMANENTLY ANCHORED RACKS FOR BICYCLES; 2. LOCKABLE BICYCLE ROOMS WITH PERMANENTLY ANCHORED RACKS; OR 3. LOCKABLE, PERMANENTLY ANCHORED BICYCLE LOCKERS. NOTE:ADDITIONAL INFORMATION ON RECOMMENDED BICYCLE ACCOMMODATIONS MAY BE OBTAINED FROM SACRAMENTO AREA BICYCLE ADVOCATES. 5.106.4.2 BICYCLE PARKING [DSA] FOR PUBLIC SCHOOLS AND COMMUNITY COLLEGES, COMPLY WITH SECTIONS 5.106.4.2.1 AND 5.106.4.2.2. 5.106.4.2.1 STUDENT BICYCLE PARKING PROVIDE PERMANENTLY ANCHORED BICYCLE RACKS CONVENIENTLY ACCESSED WITH A MINIMUM OF FOUR TWO-BIKE CAPACITY RACKS PER NEW BUILDING. 5.106.4.2.2 STAFF BICYCLE PARKING PROVIDE PERMANENT, SECURE BICYCLE PARKING CONVENIENTLY ACCESSED WITH A MINIMUM OF TWO STAFF BICYCLE PARKING SPACES PER NEW BUILDING. ACCEPTABLE BICYCLE PARKING FACILITIES SHALL BE CONVENIENT FROM THE STREET OR STAFF PARKING AREA AND SHALL MEET ONE OF THE FOLLOWING: 1. COVERED, LOCKABLE ENCLOSURES WITH PERMANENTLY ANCHORED RACKS FOR BICYCLES; 2. LOCKABLE BICYCLE ROOMS WITH PERMANENTLY ANCHORED RACKS; OR 3. LOCKABLE, PERMANENTLY ANCHORED BICYCLE LOCKERS. 5.106.5.3 ELECTRIC VEHICLE (EV) CHARGING [N] CONSTRUCTION TO PROVIDE ELECTRIC VEHICLE INFRASTRUCTURE AND FACILITATE ELECTRIC VEHICLE CHARGING SHALL COMPLY W ITH SECTION 5.106.5.3.1 AND SHALL BE PROVIDED IN ACCORDANCE WITH REGULATIONS IN THE CALIFORNIA BUILDING CODE AND THE CALIFORNIA ELECTRICAL CODE. EXCEPTIONS: 1. ON A CASE-BY-CASE BASIS WHERE THE LOCAL ENFORCING AGENCY HAS DETERMINED COMPLIANCE WITH THIS SECTION IS NOT FEASIBLE BASED UPON ONE OF THE FOLLOWING CONDITIONS: a. WHERE THERE IS NO LOCAL UTILITY POWER SUPPLY. b. WHERE THE LOCAL UTILITY IS UNABLE TO SUPPLY ADEQUATE POWER. c. WHERE THERE IS EVIDENCE SUITABLE TO THE LOCAL ENFORCEMENT AGENCY SUBSTANTIATING THAT ADDITIONAL LOCAL UTILITY INFRASTRUCTURE DESIGN REQUIREMENTS, DIRECTLY RELATED TO THE IMPLEMENTATION OF SECTION 5.106.5.3, MAY ADVERSELY IMPACT THE CONSTRUCTION COST OF THE PROJECT. 2. PARKING SPACES ACCESSIBLE ONLY BY AUTOMATED MECHANICAL CAR PARKING SYSTEMS ARE NOT REQUIRED TO COMPLY WITH THIS CODE SECTION. 5.106.5.3.1 EV CAPABLE SPACES EV CAPABLE SPACES SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 5.106.5.3.1 AND THE FOLLOWING REQUIREMENTS: 1. RACEWAYS COMPLYING WITH THE CALIFORNIA ELECTRICAL CODE AND NO LESS THAN 1-INCH DIAMETER SHALL BE PROVIDED AND SHALL ORIGINATE AT A SERVICE PANEL OR A SUBPANEL(S) SERVING THE AREA, AND SHALL TERMINATE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF THE EV CAPABLE SPACE AND INTO A SUITABLE LISTED CABINET, BOX, ENCLOSURE OR EQUIVALENT. A COMMON RACEWAY MAY BE USED TO SERVE MULTIPLE EV CAPABLE SPACES. 2. A SERVICE PANEL OR SUBPANEL(S) SHALL BE PROVIDED WITH PANEL SPACE AND ELECTRICAL LOAD CAPACITY FOR A DEDICATED 208/240 VOLT, 40-AMPERE MINIMUM BRANCH CIRCUIT FOR EACH EV CAPABLE SPACE, WITH DELIVERY OF 30-AMPERE MINIMUM TO AN INSTALLED EVSE AT EACH EVCS. 3. THE ELECTRICAL SYSTEM AND ANY ON-SITE DISTRIBUTION TRANSFORMERS SHALL HAVE SUFFICIENT CAPACITY TO SUPPLY FULL RATED AMPERAGE AT EACH EV CAPABLE SPACE. 4. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE RESERVED OVERCURRENT PROTECTIVE DEVICE SPACE(S) AS "EV CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE." NOTE: A PARKING SPACE SERVED BY ELECTRIC VEHICLE SUPPLY EQUIPMENT OR DESIGNED AS A FUTURE EV CHARGING SPACE SHALL COUNT AS AT LEAST ONE STANDARD AUTOMOBILE PARKING SPACE ONLY FOR THE PURPOSE OF COMPLYING WITH ANY APPLICABLE MINIMUM PARKING SPACE REQUIREMENTS ESTABLISHED BY AN ENFORCEMENT AGENCY. SEE VEHICLE CODE SECTION 22511.2 FOR FURTHER DETAILS. 2 THE NUMBER OF REQUIRED EVCS (EV CAPABLE SPACES PROVIDED WITH EVSE) IN COLUMN 3 COUNT TOWARD THE TOTAL NUMBER OF REQUIRED EV CAPABLE SPACES SHOWN IN COLUMN 2. SECTION 303 PHASED PROJECTS 303.1 PHASED PROJECTS. FOR SHELL BUILDINGS AND OTHERS CONSTRUCTED FOR FUTURE TENANT IMPROVEMENTS, ONLY THOSE CODE MEASURES RELEVANT TO THE BUILDING COMPONENTS AND SYSTEMS CONSIDERED TO BE NEW CONSTRUCTION (OR NEWLY CONSTRUCTED) SHALL APPLY. 303.1.1 INITIAL TENANT IMPROVEMENTS THE PROVISIONS OF THIS CODE SHALL APPLY ONNLY TO THE INITIAL TENANT IMPROVEMENTS TO A PROJECT. SUBSEQUENT TENANT IMPROVEMENTS SHALL COMPLY WITH THE SCOPING PROVISIONS IN SECTION 301.3 NON-RESIDENTIAL ADDITIONS AND ALTERATIONS. 1 IESNA LIGHTING ZONES 0 ARE NOT APPLICABLE; REFER TO LIGHTING ZONES AS DEFINED IN THE CALIFORNIA ENERGY CODE AND CHAPTER 10 OF THE CALIFORNIA ADMINISTRATIVE CODE. 2 FOR PROPERTY LINES THAT ABUT PUBLIC WALKWAYS, BIKEWAYS, PLAZAS AND PARKING LOTS, THE PROPERTY LINE MAY BE CONSIDERED TO BE 5 FEET BEYOND THE ACTUAL PROPERTY LINE FOR PURPOSE OF DETERMINING COMPLIANCE WITH THIS SECTION. FOR PROPERTY LINES THAT ABUT PUBLIC ROADWAYS AND PUBLIC TRANSIT CORRIDORS, THE 5.106.8.1 FACING -BACKLIGHT LUMINAIRES WITHIN 2MH OF A PROPERTY LINE SHALL BE ORIENTED SO THAT THE NEAREST PROPERTY LINE IS BEHIND THE FIXTURE, AND SHALL COMPLY WITH THE BACKLIGHT RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE LIGHTING ZONE AND DISTANCE TO THE NEAREST POINT OF THAT PROPERTY LINE. EXCEPTION:CORNERS. IF TWO PROPERTY LINES (OR TWO SEGMENTS OF THE SAME PROPERTY LINE) HAVE EQUIDISTANT POINTS TO THE LUMINAIRE, THEN THE LUMINAIRE MAY BE ORIENTED SO THAT THE INTERSECTION OF THE TWO LINES (THE CORNER) IS DIRECTLY BEHIND THE LUMINAIRE. THE LUMINAIRE SHALL STILL USE THE DISTANCE TO THE NEAREST POINT(S) ON THE PROPERTY LINES TO DETERMINE THE REQUIRED BACKLIGHT RATING. 5.106.8.2 FACING -GLARE FOR LUMINAIRES COVERED BY 5.106.8.1, IF A PROPERTY LINE ALSO EXISTS WITHIN OR EXTENDS INTO THE FRONT HEMISPHERE WITHIN 2MH OF THE LUMINAIRE THEN THE LUMINAIRE SHALL COMPLY WITH THE MORE STRINGENT GLARE RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE LIGHTING ZONE AND DISTANCE TO THE NEAREST POINT ON THE NEAREST PROPERTY LINE WITHIN THE FRONT HEMISPHERE. 5.106.10 GRADING AND PAVING CONSTRUCTION PLANS SHALL INDICATE HOW SITE GRADING OR A DRAINAGE SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING BUILDINGS. EXAMPLES OF METHODS TO MANAGE SURFACE WATER INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. SWALES. 2. WATER COLLECTION AND DISPOSAL SYSTEMS. 3. FRENCH DRAINS. 4. WATER RETENTION GARDENS. 5. OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM BUILDINGS AND AID IN GROUNDWATER RECHARGE. EXCEPTION:ADDITIONS AND ALTERATIONS NOT ALTERING THE DRAINAGE PATH. 5.106.12 SHADE TREES [DSA-SS] SHADE TREES SHALL BE PLANTED TO COMPLY WITH SECTIONS 5.106.12.1, 5.106.12.2, AND 5.106.12.3. PERCENTAGES SHOWN SHALL BE MEASURED AT NOON ON THE SUMMER SOLSTICE. LANDSCAPE IRRIGATION NECESSARY TO ESTABLISH AND MAINTAIN TREE HEALTH SHALL COMPLY WITH SECTION 5.304.6. 5.106.12.1 SURFACE PARKING AREAS SHADE TREE PLANTINGS, MINIMUM #10 CONTAINER SIZE OR EQUAL, SHALL BE INSTALLED TO PROVIDE SHADE OVER 50 PERCENT OF THE PARKING AREA WITHIN 15 YEARS. EXCEPTIONS:THE SURFACE PARKING AREA COVERED BY SOLAR PHOTOVOLTAIC SHADE STRUCTURES, OR SHADE STRUCTURES, WITH ROOFING MATERIALS THAT COMPLY WITH TABLE A5.106.11.2.2 IN APPENDIX A5, SHALL BE PERMITTED IN WHOLE OR IN PART IN LIEU OF SHADE TREE PLANTINGS. 5.106.12.2 LANDSCAPE AREAS SHADE TRESS PLANTINGS, MINIMUM #10 CONTAINER SIZE OR EQUAL SHALL BE INSTALLED TO PROVIDE SHADE OF 20% OF THE LANDSCAPE AREA WITHIN 15 YEARS. EXCEPTIONS:PLAYFIELDS FOR ORGANIZED SPORT ACTIVITY ARE NOT INCLUDED IN THE TOTAL AREA CALCULATION. 5.106.12.3. HARDSCAPE AREAS. SHADE TREE PLANTINGS, MINIMUM #10 CONTAINER SIZE OR EQUAL SHALL BE INSTALLED TO PROVIDE SHADE OVER 20% OF THE HARDSCAPE AREA WITHIN 15 YEARS. EXCEPTIONS:WALKS, HARDSCAPE AREAS COVERED BY SOLAR PHOTOVOLTAIC SHADE STRUCTURES, AND HARDSCAPE AREAS COVERED BY SHADE STRUCTURES WITH ROOFING MATERIALS THAT COMPLY WITH TABLE A5.106.11.2.2 IN APPENDIX A5, SHALL BE PERMITTED IN WHOLE OR IN PART IN LIEU OF SHADE TREE PLANTINGS. DESIGNATED AND MARKED PLAY AREAS OF ORGANIZED SPORT ACTIVITY ARE NOT INCLUDED IN THE TOTAL AREA CALCULATION.. 5.303 INDOOR WATER USE DIVISION 5.3 WATER EFFICIENCY AND CONSERVATION 5.201 GENERAL DIVISION 5.2 ENERGY EFFICIENCY 5.201.1 SCOPE.CALIFORNIA ENERGY CODE FOR THE PURPOSES OF MANDATORY ENERGY EFFICIENCY STANDARDS IN THIS CODE, THE CALIFORNIA ENERGY COMMISSION WILL CONTINUE TO ADOPT MANDATORY BUILDING STANDARDS. 5.301 GENERAL 5.301.1 SCOPE THE PROVISIONS OF THIS CHAPTER SHALL ESTABLISH THE MEANS OF CONSERVING WATER USED INDOORS, OUTDOORS AND IN WASTEWATER CONVEYANCE. PROPERTY LINE MAY BE CONSIDERED TO BE THE CENTERLINE OF THE PUBLIC ROADWAY OR PUBLIC TRANSIT CORRIDOR FOR THE PURPOSE OF DETERMINING COMPLIANCE WITH THIS SECTION. 3 GENERAL LIGHTING LUMINAIRES IN AREAS SUCH AS OUTDOOR PARKING, SALES OR STORAGE LOTS SHALL MEET THESE REDUCED RATINGS. DECORATIVE LUMINAIRES LOCATED IN THESE AREAS SHALL MEET U- VALUE LIMITS FOR "ALL OTHER OUTDOOR LIGHTING." 9/13/24 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 CA L G R E E N R E Q U I R E M E N T S G-204 JH JR 6/20/24 JR ARCHITECTURAL APPLICATIONS TABLE 5.504.4.1 - ADHESIVE VOC LIMIT 1,2 INDOOR CARPET ADHESIVES CARPET PAD ADHESIVES OUTDOOR CARPET ADHESIVES WOOD FLOORING ADHESIVES RUBBER FLOORING ADHESIVES SUBFLOOR ADHESIVES CERAMIC TILE ADHESIVES CURRENT VOC LIMIT 50 50 150 100 60 50 65 (LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER) VCT AND ASPHALT TILE ADHESIVES DRYWALL AND PANEL ADHESIVES COVE BASE ADHESIVES MULTIPURPOSE CONSTRUCTION ADHESIVES STRUCTURAL GLAZING ADHESIVES SINGLE-PLY ROOF MEMBRANE ADHESIVES OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 50 50 70 100 250 50 SPECIALTY APPLICATIONS PVC WELDING CPVC WELDING ABS WELDING PLASTIC CEMENT WELDING ADHESIVE PRIMER FOR PLASTIC CONTACT ADHESIVE SPECIAL PURPOSE CONTACT ADHESIVE 510 490 325 250 550 80 250 STRUCTURAL WOOD MEMBER ADHESIVE TOP AND TRIM ADHESIVES SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL PLASTIC FOAMS POROUS MATERIAL (EXCEPT WOOD) WOOD FIBERGLASS 250 140 30 50 50 30 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. HTTP://WWW.ARB.CA.GOV/DRDB/SC/CURHTML/R1168.PDF. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 2 (JANUARY 2023) 5.303.1.2 EXCESS CONSUMPTION A SEPARATE SUBMETER OR METERING DEVICE SHALL BE PROVIDED FOR ANY TENANT WITHIN A NEW BUILDING OR WITHIN AN ADDITION THAT IS PROJECTED TO CONSUME MORE THAN 1,000 GAL/DAY. 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) SHALL COMPLY WITH THE FOLLOWING: 5.303.3.1 WATER CLOSETS THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE:THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH. 5.303.3.2 URINALS 5.303.3.2.1 WALL-MOUNTED URINALS THE EFFECTIVE FLUSH VOLUME OF WALL-MOUNTED URINALS SHALL NOT EXCEED 0.125 GALLONS PER FLUSH. 5.303.3.2.2 FLOOR-MOUNTED URINALS THE EFFECTIVE FLUSH VOLUME OF FLOOR-MOUNTED OR OTHER URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH. 5.303.3.3 SHOWERHEADS. 5.303.3.3.1 SINGLE SHOWERHEAD SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT 80 PSI. SHOWERHEADS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR SHOWERHEADS. 5.303.3.3.2 MULTIPLE SHOWERHEADS SERVING ONE SHOWER WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. NOTE:A HAND-HELD SHOWER SHALL BE CONSIDERED A SHOWERHEAD. 5.303.3.4 FAUCETS AND FOUNTAINS 5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0.5 GALLONS PER MINUTE AT 60 PSI. 5.303.3.4.2 KITCHEN FAUCETS KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI, AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. 5.303.3.4.3 WASH FOUNTAINS WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE/20 [RIM SPACE (INCHES) AT 60 PSI]. 5.303.3.4.4 METERING FAUCETS METERING FAUCETS SHALL NOT DELIVER MORE THAN 0.20 GALLONS PER CYCLE. 5.303.3.4.5 METERING FAUCETS FOR WASH FOUNTAINS METERING FAUCETS FOR WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0.20 GALLONS PER CYCLE/20 [RIM SPACE (INCHES) AT 60 PSI]. NOTE:WHERE COMPLYING FAUCETS ARE UNAVAILABLE, AERATORS OR OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION. 5.303.3.4.6 PRE-RINSE SPRAY VALVE WHEN INSTALLED, SHALL MEET THE REQUIREMENTS IN THE CALIFORNIA CODE OF REGULATIONS, TITLE 20 (APPLIANCE EFFICIENCY REGULATIONS), SECTION 1605.1(H)(4) TABLE H-2, SECTION 1605.3(H)(4)(A), AND SECTION 1607(D)(7), AND SHALL BE EQUIPPED WITH AN INTEGRAL AUTOMATIC SHUTOFF. 5.303.4 COMMERCIAL KITCHEN EQUIPMENT 5.303.4.1 FOOD WASTE DISPOSERS DISPOSERS SHALL EITHER MODULATE THE USE OF WATER TO NO MORE THAN 1 GPM WHEN THE DISPOSER IS NOT IN USE (NOT ACTIVELY GRINDING FOOD WASTE/NO-LOAD) OR SHALL AUTOMATICALLY SHUT OFF AFTER NO MORE THAN 10 MINUTES OF INACTIVITY. DISPOSERS SHALL USE NO MORE THAN 8 GPM OF WATER. NOTE:THIS CODE SECTION DOES NOT AFFECT LOCAL JURISDICTION AUTHORITY TO PROHIBIT OR REQUIRE DISPOSER INSTALLATION. 5.303.5 AREAS OF ADDITION OR ALTERATION FOR THOSE OCCUPANCIES WITHIN THE AUTHORITY OF THE CALIFORNIA BUILDING STANDARDS COMMISSION AS SPECIFIED IN SECTION 103, THE PROVISIONS OF SECTIONS 5.303.3 AND 5.303.4 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATION TO THE BUILDING. 5.303.6 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1701.1 OF THE CALIFORNIA PLUMBING CODE AND IN CHAPTER 6 OF THIS CODE. 5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT 5.407.1 WEATHER PROTECTION PROVIDE A WEATHER-RESISTANT EXTERIOR WALL AND FOUNDATION ENVELOPE AS REQUIRED BY CALIFORNIA BUILDING CODE SECTION 1402.2 (WEATHER PROTECTION), MANUFACTURER’S INSTALLATION INSTRUCTIONS OR LOCAL ORDINANCE, WHICHEVER IS MORE STRINGENT. 5.407.2 MOISTURE CONTROL EMPLOY MOISTURE CONTROL MEASURES BY THE FOLLOWING METHODS. 5.407.2.1 SPRINKLERS DESIGN AND MAINTAIN LANDSCAPE IRRIGATION SYSTEMS TO PREVENT SPRAY ON STRUCTURES. 5.407.2.2 ENTRIES AND OPENINGS DESIGN EXTERIOR ENTRIES AND/OR OPENINGS SUBJECT TO FOOT TRAFFIC OR WIND-DRIVEN RAIN TO PREVENT WATER INTRUSION INTO BUILDINGS AS FOLLOWS: 5.407.2.2.1 EXTERIOR DOOR PROTECTION PRIMARY EXTERIOR ENTRIES SHALL BE COVERED TO PREVENT WATER INTRUSION BY USING NONABSORBENT FLOOR AND WALL FINISHES WITHIN AT LEAST 2 FEET AROUND AND PERPENDICULAR TO SUCH OPENINGS PLUS AT LEAST ONE OF THE FOLLOWING: 1. AN INSTALLED AWNING AT LEAST 4 FEET IN DEPTH. 2. THE DOOR IS PROTECTED BY A ROOF OVERHANG AT LEAST 4 FEET IN DEPTH. 3. THE DOOR IS RECESSED AT LEAST 4 FEET. 4. OTHER METHODS WHICH PROVIDE EQUIVALENT PROTECTION. 5.407.2.2.2 FLASHING INSTALL FLASHINGS INTEGRATED WITH A DRAINAGE PLANE. SECTION 5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 5.408.1 CONSTRUCTION WASTE MANAGEMENT RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2 OR 5.408.1.3; OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS MORE STRINGENT. 5.408.1.1 CONSTRUCTION WASTE MANAGEMENT PLAN WHERE A LOCAL JURISDICTION DOES NOT HAVE A CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE THAT IS MORE STRINGENT, SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN THAT 1. IDENTIFIES THE CONSTRUCTION AND DEMOLITION WASTE MATERIALS TO BE DIVERTED FROM DISPOSAL BY EFFICIENT USAGE, RECYCLING, REUSE ON THE PROJECT OR SALVAGE FOR FUTURE USE OR SALE. 2. DETERMINES IF CONSTRUCTION AND DEMOLITION WASTE MATERIALS WILL BE SORTED ON-SITE (SOURCE-SEPARATED) OR BULK MIXED (SINGLE STREAM). 3. IDENTIFIES DIVERSION FACILITIES WHERE CONSTRUCTION AND DEMOLITION WASTE MATERIAL COLLECTED WILL BE TAKEN. 4. SPECIFIES THAT THE AMOUNT OF CONSTRUCTION AND DEMOLITION WASTE MATERIALS DIVERTED SHALL BE CALCULATED BY WEIGHT OR VOLUME, BUT NOT BY BOTH.} 5.408.1.2 WASTE MANAGEMENT COMPANY UTILIZE A WASTE MANAGEMENT COMPANY THAT CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH THIS SECTION. NOTE:THE OWNER OR CONTRACTOR SHALL MAKE THE DETERMINATION IF THE CONSTRUCTION AND DEMOLITION WASTE MATERIAL WILL BE DIVERTED BY A WASTE MANAGEMENT COMPANY. EXCEPTIONS TO SECTIONS 5.408.1.1 AND 5.408.1.2: 1. EXCAVATED SOIL AND LAND-CLEARING DEBRIS. 2. ALTERNATE WASTE REDUCTION METHODS DEVELOPED BY WORKING WITH LOCAL AGENCIES IF DIVERSION OR RECYCLE FACILITIES CAPABLE OF COMPLIANCE WITH THIS ITEM DO NOT EXIST. 3. DEMOLITION WASTE MEETING LOCAL ORDINANCE OR CALCULATED IN CONSIDERATION OF LOCAL RECYCLING FACILITIES AND MARKETS. 5.408.1.3 WASTE STREAM REDUCTION ALTERNATIVE THE COMBINED WEIGHT OF NEW CONSTRUCTION DISPOSAL THAT DOES NOT EXCEED TWO POUNDS PER SQUARE FOOT OF BUILDING AREA MAY BE DEEMED TO MEET THE 65 PERCENT MINIMUM REQUIREMENT AS APPROVED BY THE ENFORCING AGENCY. 5.408.1.4 DOCUMENTATION DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH DEMONSTRATES COMPLIANCE WITH SECTIONS 5.408.1.1 THROUGH 5.408.1.3. THE WASTE MANAGEMENT PLAN SHALL BE UPDATED AS NECESSARY AND SHALL BE ACCESSIBLE DURING CONSTRUCTION FOR EXAMINATION BY THE ENFORCING AGENCY. NOTES: 1. SAMPLE FORMS FOUND IN “A GUIDE TO THE CALIFORNIA GREEN BUILDING STANDARDS CODE (NONRESIDENTIAL)”LOCATED AT https://www.dgs.ca.gov/BSC/Resources/Page-Content/Building-Standards- CommissionResources-List-Folder/CALGreen MAY BE USED TO ASSIST IN DOCUMENTING COMPLIANCE WITH THE WASTE MANAGEMENT PLAN. 2. MIXED CONSTRUCTION AND DEMOLITION DEBRIS (C&D) PROCESSORS CAN BE LOCATED AT THE CALIFORNIA DEPARTMENT OF RESOURCES RECYCLING AND RECOVERY (CALRECYCLE). 5.408.2 UNIVERSAL WASTE. [A] ADDITIONS AND ALTERATIONS TO A BUILDING OR TENANT SPACE THAT MEET THE SCOPING PROVISIONS IN SECTION 301.3 FOR NONRESIDENTIAL ADDITIONS AND ALTERATIONS, SHALL REQUIRE VERIFICATION THAT 5.401 GENERAL 5.401.1 SCOPE THE PROVISIONS OF THIS CHAPTER SHALL OUTLINE MEANS OF ACHIEVING MATERIAL CONSERVATION AND RESOURCE EFFICIENCY THROUGH PROTECTION OF BUILDINGS FROM EXTERIOR MOISTURE, CONSTRUCTION WASTE DIVERSION, EMPLOYMENT OF TECHNIQUES TO REDUCE POLLUTION THROUGH RECYCLING OF MATERIALS, AND BUILDING COMMISSIONING OR TESTING AND ADJUSTING. DIVISION 5.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY 5.410 BUILDING MAINTENANCE AND OPERATIONS 5.410.1 RECYCLING BY OCCUPANTS PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE DEPOSITING, STORAGE AND COLLECTION OF NON-HAZARDOUS MATERIALS FOR RECYCLING, INCLUDING (AT A MINIMUM) PAPER, CORRUGATED CARDBOARD, GLASS, PLASTICS, ORGANIC WASTE, AND METALS OR MEET A LAWFULLY ENACTED LOCAL RECYCLING ORDINANCE, IF MORE RESTRICTIVE. EXCEPTION:RURAL JURISDICTIONS THAT MEET AND APPLY FOR THE EXEMPTION IN PUBLIC RESOURCES CODE 42649.82 (A)(2)(A) ET SEQ. SHALL ALSO BE EXEMPT FROM THE ORGANIC WASTE PORTION OF THIS SECTION. 5.410.1.1 ADDITIONS ALL ADDITIONS CONDUCTED WITHIN A 12-MONTH PERIOD UNDER SINGLE OR MULTIPLE PERMITS, RESULTING IN AN INCREASE OF 30 PERCENT OR MORE IN FLOOR AREA, SHALL PROVIDE RECYCLING AREAS ON SITE. EXCEPTION:ADDITIONS WITHIN A TENANT SPACE RESULTING IN LESS THAN A 30-PERCENT INCREASE IN THE TENANT SPACE FLOOR AREA. 5.410.1.2 SAMPLE ORDINANCE SPACE ALLOCATION FOR RECYCLING AREAS SHALL COMPLY WITH CHAPTER 18, PART 3, DIVISION 30 OF THE PUBLIC RESOURCES CODE. CHAPTER 18 IS KNOWN AS THE CALIFORNIA SOLID WASTE REUSE AND RECYCLING ACCESS ACT OF 1991 (ACT). NOTE:A SAMPLE ORDINANCE FOR USE BY LOCAL AGENCIES MAY BE FOUND IN APPENDIX A OF THE DOCUMENT AT THE CALRECYCLE’S WEBSITE 5.501 GENERAL DIVISION 5.5 ENVIRONMENTAL QUALITY 5.501.1 SCOPE THE PROVISIONS OF THIS CHAPTER SHALL OUTLINE MEANS OF REDUCING THE QUANTITY OF AIR CONTAMINANTS THAT ARE ODOROUS, IRRITATING, AND/OR HARMFUL TO THE COMFORT AND WELL-BEING OF A BUILDING’S INSTALLERS, OCCUPANTS AND NEIGHBORS. 5.503 FIREPLACES 5.503.1 FIREPLACES INSTALL ONLY A DIRECT-VENT SEALED-COMBUSTION GAS OR SEALED WOOD-BURNING FIREPLACE, OR A SEALED WOOD-STOVE OR PELLET STOVE, AND REFER TO RESIDENTIAL REQUIREMENTS IN THE CALIFORNIA ENERGY CODE, TITLE 24, PART 6, SUBCHAPTER 7, SECTION 150. WOODSTOVES, PELLET STOVES AND FIREPLACES SHALL COMPLY WITH APPLICABLE LOCAL ORDINANCES. 5.503.1.1 WOODSTOVES WOODSTOVE AND PELLET STOVES SHALL COMPLY WITH U.S. EPA NEW SOURCE PERFORMANCE STANDARDS (NSPS) EMISSION LIMITS AS APPLICABLE, AND SHALL HAVE A PERMANENT LABEL INDICATING THEY ARE CERTIFIED TO MEET THE EMISSION LIMITS. 5.504 POLLUTANT CONTROL 5.504.1 TEMPORARY VENTILATION THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION. 5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. 5.504.4 FINISH MATERIAL POLLUTANT CONTROL FINISH MATERIALS SHALL COMPLY WITH SECTIONS 5.504.4.1 THROUGH 5.504.4.6. 5.504.4.1 ADHESIVES, SEALANTS AND CAULKS ADHESIVES, SEALANTS, AND CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS: 1. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2. SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE 1168 PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS (CHLOROFORM, ETHYLENE DICHLORIDE, METHYLENE CHLORIDE, PERCHLOROETHYLENE AND TRICHLOROETHYLENE), EXCEPT FOR AEROSOL PRODUCTS AS SPECIFIED IN SUBSECTION 2, BELOW. 2. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507. 5.304.6.1 NEWLY CONSTRUCTED LANDSCAPES NEW CONSTRUCTION PROJECTS WITH AN AGGREGATE LANDSCAPE AREA EQUAL TO OR GREATER THAN 500 SQUARE FEET. 5.304.6.2 REHABILITATED LANDSCAPES REHABILITATED LANDSCAPE PROJECTS WITH AN AGGREGATE LANDSCAPE AREA EQUAL TO OR GREATER THAN 1,200 SQUARE FEET. UNIVERSAL WASTE ITEMS SUCH AS FLUORESCENT LAMPS AND BALLAST AND MERCURY CONTAINING THERMOSTATS AS WELL AS OTHER CALIFORNIA PROHIBITED UNIVERSAL WASTE MATERIALS ARE DISPOSED OF PROPERLY AND ARE DIVERTED FROM LANDFILLS. A LIST OF PROHIBITED UNIVERSAL WASTE MATERIALS SHALL BE INCLUDED IN THE CONSTRUCTION DOCUMENTS. NOTE:REFER TO THE UNIVERSAL WASTE RULE LINK AT: https://dtsc.ca.gov/universalwaste/ 5.408.3 EXCAVATED SOIL AND LAND CLEARING DEBRIS 100 PERCENT OF TREES, STUMPS, ROCKS AND ASSOCIATED VEGETATION AND SOILS RESULTING PRIMARILY FROM LAND CLEARING SHALL BE REUSED OR RECYCLED. FOR A PHASED PROJECT, SUCH MATERIAL MAY BE STOCKPILED ON SITE UNTIL THE STORAGE SITE IS DEVELOPED. EXCEPTION:REUSE, EITHER ON-OR OFF-SITE, OF VEGETATION OR SOIL CONTAMINATED BY DISEASE OR PEST INFESTATION. NOTES: 1. IF CONTAMINATION BY DISEASE OR PEST INFESTATION IS SUSPECTED, CONTACT THE COUNTY AGRICULTURAL COMMISSIONER AND FOLLOW ITS DIRECTION FOR RECYCLING OR DISPOSAL OF THE MATERIAL. (www.cdfa.ca.gov/exec/county/county_contacts.html) 2. FOR A MAP OF KNOWN PEST AND/OR DISEASE QUARANTINE ZONES, CONSULT WITH THE CALIFORNIA DEPARTMENT OF FOOD AND AGRICULTURE. (www.cdfa.ca.gov) 9/13/24 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 CA L G R E E N R E Q U I R E M E N T S G-205 JH JR 6/20/24 JR COATING CATEGORY TABLE 5.504.4.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2, 3 FLAT COATINGS NONFLAT COATINGS NONFLAT-HIGH GLOSS COATINGS SPECIALTY COATINGS ALUMINUM ROOF COATINGS BASEMENT SPECIALTY COATINGS BITUMINOUS ROOF COATINGS CURRENT VOC LIMIT 50 100 150 400 400 50 (GRAMS OF VOC PER LITER OF COATING, LESS WATER AND LESS EXEMPT COMPOUNDS) BITUMINOUS ROOF PRIMERS BOND BREAKERS CONCRETE CURING COMPOUNDS CONCRETE/MASONRY SEALERS DRIVEWAY SEALERS DRY FOG COATINGS FAUX FINISHING COATINGS 350 350 350 100 50 150 350 FLOOR COATINGS FORM-RELEASE COMPOUNDS GRAPHIC ARTS COATINGS (SIGN PAINTS) HIGH TEMPERATURE COATINGS IDUSTRIAL MAINTENANCE COATINGS LOW SOLIDS COATINGS1 MAGNESITE CEMENT COATINGS MASTIC TEXTURE COATINGS 100 250 500 420 250 120 450 100 FIRE RESISTIVE COATINGS 350 METALLIC PIGMENTED COATINGS MULTICOLOR COATINGS PRETREATMENT WASH PRIMERS PRIMERS, SEALERS, AND UNDERCOATERS REACTIVE PENETRATING SEALERS RECYCLED COATINGS ROOF COATINGS RUST PREVENTATIVE COATINGS 420 250 500 100 350 250 50 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS AND UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB AND TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER AND INCLUDING EXEMPT COMPOUNDS. 2. THE SPECIFIED LIMITS REMAIN IN EFFECT ENLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEBUARY 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. PRODUCT TABLE 5.504.4.5 - FORMALDEHYDE LIMITS 1 HARDWOOD PLYWOOD VENEER CORE HARDWOOD PLYWOOD COMPOSITE CORE PARTICLEBOARD MEDIUM DENSITY FIBERBOARD THIN MEDIUM DENSITY FIBERBOARD2 CURRENT LIMIT 0.05 0.05 0.09 0.11 0.13 (MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION) 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E1333. FOR ADDITIONAL INFORMATION, SEE CALIFORNIA CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16 INCH (8MM). SEALANTS TABLE 5.504.4.2 - SEALANT VOC LIMIT ARCHITECTURAL MARINE DECK NONMEMBRANE ROOF ROADWAY SINGLE-PLY ROOF MEMBRANE OTHER CURRENT VOC LIMIT 250 760 300 250 450 420 (LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER) SEALANT PRIMERS ARCHITECTURAL NONPOROUS POROUS MODIFIED BITUMINOUS 250 775 500 MARINE DECK OTHER 760 750 NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 3 (JANUARY 2023) 5.504.4.3 PAINTS AND COATINGS ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, AS SHOWN IN TABLE 5.504.4.3, UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE SPECIALTY COATINGS CATEGORIES LISTED IN TABLE 5.504.4.3 SHALL BE DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR NONFLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED IN SUBSECTIONS 4.21, 4.36 AND 4.37 OF THE 2007 CALIFORNIA AIR RESOURCES BOARD SUGGESTED CONTROL MEASURE, AND THE CORRESPONDING FLAT, NONFLAT OR NONFLAT-HIGH GLOSS VOC LIMIT IN TABLE 5.504.4.3 SHALL APPLY. 5.504.4.4 CARPET SYSTEMS ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS FOR THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350). SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR CERTIFICATION PROGRAMS AND TESTING LABS. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.asp x#material 5.504.4.4.1 CARPET CUSHION ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350). SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR CERTIFICATION PROGRAMS AND TESTING LABS. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC .aspx#material 5.504.4.4.2 CARPET ADHESIVE ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 5.504.4.1. 5.504.4.5 COMPOSITE WOOD PRODUCTS HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN ARB’S AIR TOXIC CONTROL MEASURE (ATCM) FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ.) THOSE MATERIALS NOT EXEMPTED UNDER THE ATCM MUST MEET THE SPECIFIED EMISSION LIMITS, AS SHOWN IN TABLE 5.504.4.5. 5.504.4.5.3 DOCUMENTATION VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE FOLLOWING: 1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS. 2. CHAIN OF CUSTODY CERTIFICATIONS. 3. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE WOOD PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION 93120, ET SEQ.). 4. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR PS-2 STANDARDS OF THE ENGINEERED WOOD ASSOCIATION, THE AUSTRALIAN AS/NZS 2269 OR EUROPEAN 636 3S STANDARDS. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. 5.505.1 INDOOR MOISTURE CONTROL BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF CALIFORNIA BUILDING CODE, CCR, TITLE 24, PART 2, SECTIONS 1202 (VENTILATION) AND CHAPTER 14 (EXTERIOR WALLS). FOR ADDITIONAL MEASURES, SEE SECTION 5.407.2 OF THIS CODE. 5.505 INDOOR MOISTURE CONTROL 5.506.1 OUTSIDE AIR DELIVERY FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 (REQUIREMENTS FOR VENTILATION) OF THE CALIFORNIA ENERGY CODE,OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT, AND DIVISION 1, CHAPTER 4 OF CCR, TITLE 8. 5.506.2 CARBON DIOXIDE (CO2) MONITORING FOR BUILDINGS OR ADDITIONS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CALIFORNIA ENERGY CODE,SECTION 120(C)(4). 5.506 INDOOR AIR QUALITY 5.507.4 ACOUSTICAL CONTROL EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH SOUND TRANSMISSION CLASS (STC) VALUES DETERMINED IN ACCORDANCE WITH ASTM E90 AND ASTM E413 OR OUTDOOR-INDOOR SOUND TRANSMISSION CLASS (OITC) DETERMINED IN ACCORDANCE WITH ASTM E1332, USING EITHER THE PRESCRIPTIVE OR PERFORMANCE METHOD IN SECTION 5.507.4.1 OR 5.507.4.2. EXCEPTION:BUILDINGS WITH FEW OR NO OCCUPANTS OR WHERE OCCUPANTS ARE NOT LIKELY TO BE AFFECTED BY EXTERIOR NOISE, AS DETERMINED BY THE ENFORCEMENT AUTHORITY, SUCH AS FACTORIES, STADIUMS, STORAGE, ENCLOSED PARKING STRUCTURES AND UTILITY BUILDINGS. EXCEPTION: [DSA-SS]FOR PUBLIC SCHOOLS AND COMMUNITY COLLEGES, THE REQUIREMENTS OF THIS SECTION AND ALL SUBSECTIONS APPLY ONLY TO NEW CONSTRUCTION. 5.507.4.1 EXTERIOR NOISE TRANSMISSION, PRESCRIPTIVE METHOD WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL MEET A COMPOSITE STC RATING OF AT LEAST 50 OR A COMPOSITE OITC RATING OF NO LESS THAN 40, WITH EXTERIOR WINDOWS OF A MINIMUM STC OF 40 OR OITC OF 30 IN THE FOLLOWING LOCATIONS: 1. WITHIN THE 65 CNEL NOISE CONTOUR OF AN AIRPORT. EXCEPTIONS: 1. LDN OR CNEL FOR MILITARY AIRPORTS SHALL BE DETERMINED BY THE FACILITY AIR INSTALLATION COMPATIBLE LAND USE ZONE (AICUZ) PLAN. 2. LDN OR CNEL FOR OTHER AIRPORTS AND HELIPORTS FOR WHICH A LAND USE PLAN HAS NOT BEEN DEVELOPED SHALL BE DETERMINED BY THE LOCAL GENERAL PLAN NOISE ELEMENT. 2. WITHIN THE 65 CNEL OR LDN NOISE CONTOUR OF A FREEWAY OR EXPRESSWAY, RAILROAD, INDUSTRIAL SOURCE OR FIXED- GUIDEWAY SOURCE AS DETERMINED BY THE NOISE ELEMENT OF THE GENERAL PLAN. 5.507.4.1.1 NOISE EXPOSURE WHERE NOISE CONTOURS ARE NOT READILY AVAILABLE BUILDINGS EXPOSED TO A NOISE LEVEL OF 65 DB LEQ-1-HR DURING ANY HOUR OF OPERATION SHALL HAVE BUILDING, ADDITION OR ALTERATION EXTERIOR WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MEETING A COMPOSITE STC RATING OF AT LEAST 45 (OR OITC 35), WITH EXTERIOR WINDOWS OF A MINIMUM STC OF 40 (OR OITC 30). 5.507.4.2 PERFORMANCE METHOD FOR BUILDINGS LOCATED AS DEFINED IN SECTION 5.507.4.1 OR 5.507.4.1.1, WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL BE CONSTRUCTED TO PROVIDE AN INTERIOR NOISE ENVIRONMENT ATTRIBUTABLE TO EXTERIOR SOURCES THAT DOES NOT EXCEED AN HOURLY EQUIVALENT NOISE LEVEL (LEQ-1HR) OF 50 DBA IN OCCUPIED AREAS DURING ANY HOUR OF OPERATION. 5.507.4.2.1 SITE FEATURES EXTERIOR FEATURES SUCH AS SOUND WALLS OR EARTH BERMS MAY BE UTILIZED AS APPROPRIATE TO THE BUILDING, ADDITION OR ALTERATION PROJECT TO MITIGATE SOUND MIGRATION TO THE INTERIOR. 5.507.4.2.2 DOCUMENTATION OF COMPLIANCE AN ACOUSTICAL ANALYSIS DOCUMENTING COMPLYING INTERIOR SOUND LEVELS SHALL BE PREPARED BY PERSONNEL APPROVED BY THE ARCHITECT OR ENGINEER OF RECORD. 5.507.4.3 INTERIOR SOUND TRANSMISSION WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES AND TENANT SPACES AND PUBLIC PLACES SHALL HAVE AN STC OF AT LEAST 40. NOTE:EXAMPLES OF ASSEMBLIES AND THEIR VARIOUS STC RATINGS MAY BE FOUND AT THE CALIFORNIA OFFICE OF NOISE CONTROL: www.toolbase.org/PDF/CaseStudies/stc_icc_ratings.pdf. 5.507 ENVIRONMENTAL COMFORT 702.1 INSTALLER TRAINING HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF HVAC SYSTEMS INCLUDING DUCTS AND EQUIPMENT BY A NATIONALLY OR REGIONALLY RECOGNIZED TRAINING OR CERTIFICATION PROGRAM. UNCERTIFIED PERSONS MAY PERFORM HVAC INSTALLATIONS WHEN UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF A PERSON TRAINED AND CERTIFIED TO INSTALL HVAC SYSTEMS OR CONTRACTOR LICENSED TO INSTALL HVAC SYSTEMS. EXAMPLES OF ACCEPTABLE HVAC TRAINING AND CERTIFICATION PROGRAMS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: 1. STATE CERTIFIED APPRENTICESHIP PROGRAMS. 2. PUBLIC UTILITY TRAINING PROGRAMS. 3. TRAINING PROGRAMS SPONSORED BY TRADE, LABOR OR STATEWIDE ENERGY CONSULTING OR VERIFICATION ORGANIZATIONS. 4. PROGRAMS SPONSORED BY MANUFACTURING ORGANIZATIONS. 5. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY. 702.2 SPECIAL INSPECTION [HCD] WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE RESPONSIBLE ENTITY ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE. SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF INSPECTION OR TASK TO BE PERFORMED. IN ADDITION TO OTHER CERTIFICATIONS OR QUALIFICATIONS ACCEPTABLE TO THE ENFORCING AGENCY, THE FOLLOWING CERTIFICATIONS OR EDUCATION MAY BE CONSIDERED BY THE ENFORCING AGENCY WHEN EVALUATING THE QUALIFICATIONS OF A SPECIAL INSPECTOR: 1. CERTIFICATION BY A NATIONAL OR REGIONAL GREEN BUILDING PROGRAM OR STANDARD PUBLISHER. 2. CERTIFICATION BY A STATEWIDE ENERGY CONSULTING OR VERIFICATION ORGANIZATION, SUCH AS HERS RATERS, BUILDING PERFORMANCE CONTRACTORS, AND HOME ENERGY AUDITORS. 3. SUCCESSFUL COMPLETION OF A THIRD PARTY APPRENTICE TRAINING PROGRAM IN THE APPROPRIATE TRADE. 4. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY. NOTES: 1. SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING FOR COMPLIANCE WITH THIS CODE. 2. HERS RATERS ARE SPECIAL INSPECTORS CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION (CEC) TO RATE HOMES IN CALIFORNIA ACCORDING TO THE HOME ENERGY RATING SYSTEM (HERS). [BSC-CG]WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE RESPONSIBLE ENTITY ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THIS CODE. SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF INSPECTION OR TASK TO BE PERFORMED. IN ADDITION, THE SPECIAL INSPECTOR SHALL HAVE A CERTIFICATION FROM A RECOGNIZED STATE, NATIONAL OR INTERNATIONAL ASSOCIATION, AS DETERMINED BY THE LOCAL AGENCY. THE AREA OF CERTIFICATION SHALL BE CLOSELY RELATED TO THE PRIMARY JOB FUNCTION, AS DETERMINED BY THE LOCAL AGENCY. NOTE: SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING FOR COMPLIANCE WITH THIS CODE. 703.1 DOCUMENTATION. DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL INCLUDE BUT IS NOT LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY WHICH DEMONSTRATE SUBSTANTIAL CONFORMANCE. WHEN SPECIFIC DOCUMENTATION OR SPECIAL INSPECTION IS NECESSARY TO VERIFY COMPLIANCE, THAT METHOD OF COMPLIANCE WILL BE SPECIFIED IN THE APPROPRIATE SECTION OR IDENTIFIED APPLICABLE CHECKLIST. CHAPTER 7 - INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 703 VERIFICATIONS OUTSIDE DIAMETER (OD) LESS THAN 1/4 INCH, FLARED TUBING CONNECTIONS AND SHORT RADIUS ELBOWS SHALL NOT BE USED IN REFRIGERANT SYSTEMS EXCEPT AS NOTED BELOW. 5.508.2.1.1 THREADED PIPE THREADED CONNECTIONS ARE PERMITTED AT THE COMPRESSOR RACK. 5.508.2.1.2 COPPER PIPE COPPER TUBING WITH AN OD LESS THAN 1/4 INCH MAY BE USED IN SYSTEMS WITH A REFRIGERANT CHARGE OF 5 POUNDS OR LESS. 5.508.2.1.2.1 ANCHORAGE ONE-FOURTH-INCH OD TUBING SHALL BE SECURELY CLAMPED TO A RIGID BASE TO KEEP VIBRATION LEVELS BELOW 8 MILS. 5.508.2.1.3 FLARED TUBING CONNECTIONS DOUBLE-FLARED TUBING CONNECTIONS MAY BE USED FOR PRESSURE CONTROLS, VALVE PILOT LINES AND OIL. EXCEPTION:SINGLE-FLARED TUBING CONNECTIONS MAY BE USED WITH A MULTIRING SEAL COATED WITH INDUSTRIAL SEALANT SUITABLE FOR USE WITH REFRIGERANTS AND TIGHTENED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. 5.508.2.1.4 ELBOWS SHORT RADIUS ELBOWS ARE ONLY PERMITTED WHERE SPACE LIMITATIONS PROHIBIT USE OF LONG RADIUS ELBOWS. 5.508.2.2 VALVES VALVES AND FITTINGS SHALL COMPLY WITH THE CALIFORNIA MECHANICAL CODE AND AS FOLLOWS. 5.508.2.2.1 PRESSURE RELIEF VALVES FOR VESSELS CONTAINING HIGH-GWP REFRIGERANT, A RUPTURE DISC SHALL BE INSTALLED BETWEEN THE OUTLET OF THE VESSEL AND THE INLET OF THE PRESSURE RELIEF VALVE. 5.508.2.2.1.1 PRESSURE DETECTION A PRESSURE GAUGE, PRESSURE TRANSDUCER OR OTHER DEVICE SHALL BE INSTALLED IN THE SPACE BETWEEN THE RUPTURE DISC AND THE RELIEF VALVE INLET TO INDICATE A DISC RUPTURE OR DISCHARGE OF THE RELIEF VALVE. 5.508.2.2.2 ACCESS VALVES ONLY SCHRADER ACCESS VALVES WITH A BRASS OR STEEL BODY ARE PERMITTED FOR USE. 5.508.2.2.2.1 VALVE CAPS FOR SYSTEMS WITH A REFRIGERANT CHARGE OF 5 POUNDS OR MORE, VALVE CAPS SHALL BE BRASS OR STEEL AND NOT PLASTIC. 5.508.2.2.2.2 SEAL CAPS IF DESIGNED FOR IT, THE CAP SHALL HAVE A NEOPRENE O-RING IN PLACE. 5.508.2.2.2.2.1 CHAIN TETHERS CHAIN TETHERS TO FIT OVER THE STEM ARE REQUIRED FOR VALVES DESIGNED TO HAVE SEAL CAPS. EXCEPTION:VALVES WITH SEAL CAPS THAT ARE NOT REMOVED FROM THE VALVE DURING STEM OPERATION. 5.508.2.3 REFRIGERATED SERVICE CASES REFRIGERATED SERVICE CASES HOLDING FOOD PRODUCTS CONTAINING VINEGAR AND SALT SHALL HAVE EVAPORATOR COILS OF CORROSION-RESISTANT MATERIAL, SUCH AS STAINLESS STEEL; OR BE COATED TO PREVENT CORROSION FROM THESE SUBSTANCES. 5.508.2.3.1 COIL COATING CONSIDERATION SHALL BE GIVEN TO THE HEAT TRANSFER EFFICIENCY OF COIL COATING TO MAXIMIZE ENERGY EFFICIENCY. 5.508.2.4 REFRIGERANT RECEIVERS REFRIGERANT RECEIVERS WITH CAPACITIES GREATER THAN 200 POUNDS SHALL BE FITTED WITH A DEVICE THAT INDICATES THE LEVEL OF REFRIGERANT IN THE RECEIVER. 5.508.2.5 PRESSURE TESTING THE SYSTEM SHALL BE PRESSURE TESTED DURING INSTALLATION PRIOR TO EVACUATION AND CHARGING. 5.508.2.5.1 MINIMUM PRESSURE THE SYSTEM SHALL BE CHARGED WITH REGULATED DRY NITROGEN AND APPROPRIATE TRACER GAS TO BRING SYSTEM PRESSURE UP TO 300 PSIG MINIMUM. 5.508.2.5.2 LEAKS CHECK THE SYSTEM FOR LEAKS, REPAIR ANY LEAKS, AND RETEST FOR PRESSURE USING THE SAME GAUGE. 5.508.2.5.3 ALLOWABLE PRESSURE CHANGE THE SYSTEM SHALL STAND, UNALTERED, FOR 24 HOURS WITH NO MORE THAN A +/-ONE POUND PRESSURE CHANGE FROM 300 PSIG, MEASURED WITH THE SAME GAUGE. 5.508.2.6 EVACUATION THE SYSTEM SHALL BE EVACUATED AFTER PRESSURE TESTING AND PRIOR TO CHARGING. 5.508.2.6.1 FIRST VACUUM PULL A SYSTEM VACUUM DOWN TO AT LEAST 1000 MICRONS (+/-50 MICRONS), AND HOLD FOR 30 MINUTES. 5.508.2.6.2 SECOND VACUUM PULL A SECOND SYSTEM VACUUM TO A MINIMUM OF 500 MICRONS AND HOLD FOR 30 MINUTES. 5.508.2.6.3 THIRD VACUUM PULL A THIRD VACUUM DOWN TO A MINIMUM OF 300 MICRONS, AND HOLD FOR 24 HOURS WITH A MAXIMUM DRIFT OF 100 MICRONS OVER A 24-HOUR PERIOD. 5.508.1 OZONE DEPLETION AND GREENHOUSE GAS REDUCTIONS INSTALLATIONS OF HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL COMPLY WITH SECTIONS 5.508.1.1 AND 5.508.1.2. 5.508.1.1 CHLOROFLUOROCARBONS (CFCS) INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN CFCS. 5.508.1.2 HALONS INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN HALONS. 5.508.2 SUPERMARKET REFRIGERANT LEAK REDUCTION NEW COMMERCIAL REFRIGERATION SYSTEMS SHALL COMPLY WITH THE PROVISIONS OF THIS SECTION WHEN INSTALLED IN RETAIL FOOD STORES 8,000 SQUARE FEET OR MORE CONDITIONED AREA, AND THAT UTILIZE EITHER REFRIGERATED DISPLAY CASES, OR WALK-IN COOLERS OR FREEZERS CONNECTED TO REMOTE COMPRESSOR UNITS OR CONDENSING UNITS. THE LEAK REDUCTION MEASURES APPLY TO REFRIGERATION SYSTEMS CONTAINING HIGH-GLOBAL-WARMING POTENTIAL (HIGH-GWP) REFRIGERANTS WITH A GWP OF 150 OR GREATER. NEW REFRIGERATION SYSTEMS INCLUDE BOTH NEW FACILITIES AND THE REPLACEMENT OF EXISTING REFRIGERATION SYSTEMS IN EXISTING FACILITIES. EXCEPTION:REFRIGERATION SYSTEMS CONTAINING LOW-GLOBAL WARMING POTENTIAL (LOW-GWP) REFRIGERANT WITH A GWP VALUE LESS THAN 150 ARE NOT SUBJECT TO THIS SECTION. LOW -GWP REFRIGERANTS ARE NONOZONE- DEPLETING REFRIGERANTS THAT INCLUDE AMMONIA, CARBON DIOXIDE (CO2), AND POTENTIALLY OTHER REFRIGERANTS. 5.508.2.1 REFRIGERANT PIPING PIPING COMPLIANT WITH THE CALIFORNIA MECHANICAL CODE SHALL BE INSTALLED TO BE ACCESSIBLE FOR LEAK PROTECTION AND REPAIRS. PIPING RUNS USING THREADED PIPE, COPPER TUBING WITH AN 5.508 OUTDOOR AIR QUALITY 5.504.4.3.1 AEROSOL PAINTS AND COATINGS AEROSOL PAINTS AND COATINGS SHALL MEET THE PWMIR LIMITS FOR ROC IN SECTION 94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(C)(2) AND (D)(2) OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER THE JURISDICTION OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT ADDITIONALLY COMPLY WITH THE PERCENT VOC BY WEIGHT OF PRODUCT LIMITS OF REGULATION 8 RULE 49. 5.504.4.3.2 VERIFICATION VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: 1. MANUFACTURER’S PRODUCT SPECIFICATION 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS 5.504.4.6 RESILIENT FLOOR SYSTEMS WHERE RESILIENT FLOORING IS INSTALLED, AT LEAST 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL MEET THE REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350). SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR CERTIFICATION PROGRAMS AND TESTING LABS. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.asp x#material 5.504.4.6.1 VERIFICATION OF COMPLIANCE DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT RESILIENT FLOORING MATERIALS MEET THE POLLUTANT EMISSION LIMITS. 5.504.5.3 FILTERS IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT PROVIDES AT LEAST A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8. MERV 8 FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY, AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. EXCEPTION:EXISTING MECHANICAL EQUIPMENT. 5.504.5.3.1 LABELING INSTALLED FILTERS SHALL BE CLEARLY LABELED BY THE MANUFACTURER INDICATING THE MERV RATING. 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. 9/13/24 PF UP EXISTING 1 HR SHAFT ENCLOSURE (ASSUMED, VIF) EGRESS PATH, SEE TABLE FOR CALCULATED DISTANCES NUMBER OF OCCUPANTS EXITING SPACE COMBINED OCCUPANT COUNT ALONG P.O.T. (X) [X] CA EXISTING BUILDING CODE - 503.1 ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH REQUIREMENTS OF CBC AS APPLICABLE, FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NOT LESS COMPLYING WITH WITH THE PROVISIONS OF THE CBC THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION USE AND OCCUPANCY CLASSIFICATION (CHAPTER 3) EXISTING: BUSINESS GROUP B OCCUPANCY PROPOSED: BUSINESS GROUP B OCCUPANCY ASSEMBLY GROUP A-3 OCCUPANCY (BRIEFING ROOM ONLY) GENERAL BUILDING HEIGHTS AND AREAS (CHAPTER 5) CONSTRUCTION TYPE: VB (NO CHANGE) EXISTING BUILDING HEIGHT: 35' (NO CHANGE) ALLOWED BUILDING HEIGHT: 60' (A GOVERNS, WITHOUT AREA INCREASE) EXISTING NUMBER OF STORIES: 2 (NO CHANGE) ALLOWED NUMBER OF STORIES 2 (A GOVERNS, WITHOUT AREA INCREASE) ALLOWABLE AREA OF EACH STORY (MIXED OCCUPANCY 506.2.2) 1ST FLOOR: 5,586 SF EXISTING/PROPOSED (NO CHANGE, B & A-3 OCCUPANCY) 6,000 SF ALLOWABLE (SM, A-3 GOVERNS WITH HEIGHT INCREASE) 2ND FLOOR: 5,335 SF EXISTING/PROPOSED (NO CHANGE, B OCCUPANCY) 6,000 SF ALLOWABLE (SM, A-3 GOVERNS WITH HEIGHT INCREASE) TYPES OF CONSTRUCTION (CHAPTER 6) NO FIRE RATINGS REQUIRED IN VB CONSTRUCTION PER TABLE 601 FIRE PROTECTION AND LIFE SAFETY SYSTEMS (CHAPTER 9) FULLY SPRINKLERED MEANS OF EGRESS (CHAPTER 10) OCCUPANT LOAD OF AREA OF WORK (TABLE 1004.5) SEE SCHEDULE BELOW MEANS OF EGRESS SIZING SEE PLAN NUMBER OF EXITS EXISTING: 2 REQUIRED: 2 EXIT CONFIGURATION (1007.1.1) MAX DIAGONAL: SEE PLAN REQ'D SEPARATION: 1/3 DIAGONAL, 1007.1.1 EXCEPTION 2 PROPOSED SEPARATION: SEE PLAN EXIT ACCESS TRAVEL DISTANCE: MAX TRAVEL DISTANCE: 250 FT (TABLE 1017.2, SPRINKLERED A GOVERNS) COMMON PATH OF TRAVEL MAXIMUM: 75 FT (TABLE 1006.2.1, SPRINKLERED A GOVERNS) EXIT DISCHARGE ACCESS TO PUBLIC WAY: SEE SITE PLAN AREAS OF ASSISTED RESCUE PROVIDED: SEE SITE PLAN PLUMBING FIXTURE CALCULATIONS (CPC 422.1) OCCUPANTS BY OCCUPANCY (PER CPC TABLE 4-1, SEE OCCUPANCY TABLE BLW) B: 114 OCCUPANTS (57 MALE, 57 FEMALE) A-3: 27 OCCUPANTS (13 MALE, 14 FEMALE) WATER CLOSETS REQUIRED B MALE (2:51-100): 1.14 B FEMALE (4: 51-100): 3.14 A-3 MALE (1:1-100): 0.13 A-3 FEMALE (1:1-25): 0.56 MALE TOTAL REQ'D: 1.27 = 2 FEMALE TOTAL REQ'D: 3.7 = 4 MALE PROVIDED: 3 FEMALE PROVIDED: 4 URINAL REQUIRED B MALE (1:1-100): 0.57 A-3 MALE (1:1-100): 0.13 MALE TOTAL REQ'D: 0.70 = 1 MALE PROVIDED: 1 LAVATORIES REQUIRED B MALE (1:1-75): 0.76 B FEMALE (2:51-100): 1.14 A-3 MALE (1:200): 0.07 A-3 FEMALE (1:100): 0.14 MALE TOTAL REQ'D: 0.83 = 1 FEMALE TOTAL REQ'D: 1.28 = 2 MALE PROVIDED: 2 FEMALE PROVIDED: 3 DRINKING FOUNTAINS REQUIRED B (1:150): 0.76 A-3 (1:250): 0.11 TOTAL REQ'D: 0.87 = 1 TOTAL PROVIDED: 2 SERVICE SINK REQUIRED 1 SERVICE SINK PROVIDED 2 806 SF BRIEFING ROOM 137 SF STORAGE 1848 SF OPEN OFFICE 123 SF ELECTRICAL126 SF MEETING 86 SF OFFICE 74 SF ELEVATOR 260 SF VESTIBULE 151 SF NORTH STAIR 354 SF SHARED OFFICE 149 SF OFFICE 238 SF STORAGE 160 SF EQUIPMENT 151 SF SOUTH STAIR 125 SF OFFICE 240 SF BREAK ROOM 131 SF HALL 17 SF JAN 76 SF MEN 66 SF WOMEN [ 108 ] [ 6 0 ] [ 13 ] [ 5 5 ] [ 84 ][ 29 ] OCCUPANCY GROUP LEGEND A-3 B ( 5 ) ( 1 ) [ 2 ] ( 1 ) [ 2 ] ( 9 ) ( 1 ) ( 1 ) ( 1 ) ( 1 ) 43 SF HALL [ 19 ] ( 1 ) [ 2 ] [ 3 2 ] [ 3 3 ] [ 1 0 ] ( 1 7 ) 103 SF STORAGE ( 7 )( 6 ) ( 2 )(E) FIRE EXTINGUISHER CABINET (E) FIRE EXTINGUISHER CABINET 679 SF CONFERENCE ROOM 171 SF STORAGE 85 SF IT 369 SF HALL / FLEX SPACE 133 SF MEETING ROOM 134 SF OFFICE 129 SF OFFICE 244 SF BREAK ROOM 266 SF OFFICE 150 SF MEN'S 183 SF WOMENS 262 SF BREAK ROOM 165 SF EXIT ACCESS STAIRWAY 43 SF SHAFT 452 SF OFFICE 265 SF ADMIN 155 SF OFFICE 139 SF OFFICE 89 SF ELEV MECH 137 SF COPY 277 SF HALL / FLEX SPACE 77 SF ELEVATOR 154 SF EXIT ACCESS STAIRWAY 129 SF OFFICE 132 SF OFFICE 16 SF JAN[ 60 ] [ 55 ] CLR 44 3/4" 44" MIN CLR (CBC 1011.2) 44" MIN CLR (CBC 1011.2) 44 1/2" ( 9 ) ( 1 ) ( 1 )( 17 )( 2 ) ( 1 ) ( 1 ) ( 1 ) ( 1 ) ( 1 ) ( 1 8 ) ( 2 )( 2 )( 2 )( 1 )( 1 ) 200 SF HALL 106' - 1" MAX DIAGONAL 75' - 5" EXIT SEPARATION 92 SF HALL ( 1 ) ( 2 3 ) ( 2 3 ) ( 3 )[ 2 ][ 4 ]( 2 ) ( 1 ) ( 1 ) [ 6 ] [ 6 ] [ 3 0 ] [ 2 9 ] [ 30 ] [ 33 ] CLR 2' - 2 5/8" (E) FIRE EXTINGUISHER CABINET (N) FIRE EXTINGUISHER CABINET (N) FIRE EXTINGUISHER CABINET C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated CO D E A N A L Y S I S G-401 JH JR 6/20/24 JR FIRST FLOOR OCCUPANCY CALCULATIONS SECOND FLOOR OCCUPANCY CALCULATIONS LEGEND AREA NAME AREA NET / GROSS OCCUPANCY PLUMBING FIXTURE CALC MAX. OCC. LOAD FOR ONE EXIT (2022 CBC TABLE 1006.2.1) EXITS REQ'DTYPE FUNCTION OF SPACE (2022 CBC TABLE 1004.5) LOAD FACTOR OCC LOAD LOAD FACTOR OCC LOAD ELEVATOR 74 SF B (none)49 1 HALL 131 SF B (none)49 1 HALL 43 SF B (none)49 MEN 76 SF B (none)49 1 NORTH STAIR 151 SF B (none)49 1 SOUTH STAIR 151 SF B (none)49 1 WOMEN 66 SF B (none)49 1 (none): 7 0 0 ELECTRICAL 123 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 EQUIPMENT 160 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 JAN 17 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 STORAGE 137 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 STORAGE 238 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 STORAGE 103 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM: 6 6 6 BREAK ROOM 240 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 17 30 9 49 1 BRIEFING ROOM 806 SF NET A-3 ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 54 30 27 49 2 MEETING 126 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 9 30 5 49 1 ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS): 3 80 41 OFFICE 86 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 OFFICE 149 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 OFFICE 125 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 OPEN OFFICE 1848 SF GROSS B BUSINESS AREAS 150 13 150 13 49 1 VESTIBULE 260 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1 BUSINESS AREAS: 5 18 18 SHARED OFFICE 354 SF SEE SECTION 1004.8 B CONCENTRATED BUSINESS USE AREAS 49 1 CONCENTRATED BUSINESS USE AREAS: 1 0 0 CODE ANALYSIS (CBC 2022) COMMON PATH FIRST FLOOR 51' - 4" NORTH STAIR - MAX TRAVEL 154' - 4" SOUTH STAIR - MAX TRAVEL 146' - 5" A.L.S. NOTES FUNCTION OF SPACE AREA SF/OCCUPANT OCCUPANT LOAD BRIEFING ROOM 806 SF @ 15 SF/OCC 54 OCC CONFERENCE ROOM 679 SF @ 15 SF/OCC 46 OCC MEETING (1ST FLOOR) 126 SF @ 15 SF/OCC 9 OCC MEETING (2ND FLOOR) 133 SF @ 15 SF/OCC 9 OCC ASSITIVE LISTENING DEVICES CBC SECTION 11B-219 1. PROVIDE PERSONAL RECEIVERS FOR 5 PEOPLE (4% OF TOTAL NUMBER OF SEATS) WITH HEARING IMPAIRMENTS 2. 2 SYSTEMS TO BE HEARING AID COMPATIBLE (25% OF SYSTEMS) 3. SYSTEMS TO BE PORTABLE 4. DEVICES TO BE PROVIDED BY OWNER. CONTRACTOR TO PROVIDE ALL SIGNAGE AREA NAME AREA NET / GROSS OCCUPANCY PLUMB FIXT CALC MAX. OCC. LOAD FOR ONE EXIT (2022 CBC TABLE 1006.2.1) EXITS REQ'DTYPE FUNCTION OF SPACE (2022 CBC TABLE 1004.5) LOAD FACTOR OCC LOAD LOAD FACTOR OCC LOAD ELEVATOR 77 SF B (none)49 1 EXIT ACCESS STAIRWAY 165 SF B (none)49 1 EXIT ACCESS STAIRWAY 154 SF B (none)49 1 HALL 200 SF B (none)49 HALL 92 SF B (none)49 1 MEN'S 150 SF B (none)49 1 SHAFT 43 SF B (none)49 1 WOMENS 183 SF B (none)49 1 (none): 8 0 0 ELEV MECH 89 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 IT 85 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 JAN 16 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 STORAGE 171 SF GROSS B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 300 1 49 1 ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM: 4 4 4 BREAK ROOM 244 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 17 30 9 49 1 BREAK ROOM 262 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 18 30 9 49 1 CONFERENCE ROOM 679 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 46 30 23 49 1 MEETING ROOM 133 SF NET B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 9 30 5 49 1 ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS): 4 90 46 ADMIN 265 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1 COPY 137 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 HALL / FLEX SPACE 369 SF GROSS B BUSINESS AREAS 150 3 150 3 49 1 HALL / FLEX SPACE 277 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1 OFFICE 134 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 OFFICE 129 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 OFFICE 266 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1 OFFICE 452 SF GROSS B BUSINESS AREAS 150 4 150 4 49 1 OFFICE 155 SF GROSS B BUSINESS AREAS 150 2 150 2 49 1 OFFICE 139 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 OFFICE 129 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 OFFICE 132 SF GROSS B BUSINESS AREAS 150 1 150 1 49 1 BUSINESS AREAS: 12 21 21 115 71 5 5 5 5 109 70 1 9/13/24 NOTE: 1. THE REQUIRED CLEAR FLOOR SPACE MAY NOT OVERLAP THE REQUIRED KNEE SPACE BY MORE THAN 19". 2. KNEE CLEARANCES AT TABLES, COUNTERS & WORKSURFACES IS AT LEAST 27" HIGH, 30" WIDE AND 19" DEEP. REF: 2022 CBC 11B-306 PLANELEVATION 29 " M I N . 8" MIN. 27 " M I N . 11" MIN.6" MIN. 9" M I N . 30" MIN. 48 " M I N . C L R . 25 " M A X . 17 " M I N . PULL SIDE PUSH SIDE * 48" MIN. CLR. IF DOOR HAS BOTH A LATCH AND A CLOSER H) J,K)24" MIN. 24" MIN. REF: 2022 CBC 11B-404.2.4 44 " M I N . C L R . 60 " M I N . C L R . PULL SIDE PUSH SIDE * 48" MIN. CLR. IF DOOR HAS BOTH A LATCH AND A CLOSER F,G) D) REF: 2019 CBC 11B-404.2.4 44 " M I N . C L R . 60 " M I N . C L R . 36" MIN. CLR. 22" MIN. PUSH SIDE PULL SIDE *PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER B,C) A) NOTE: ALL DOORS IN ALCOVES SHLAL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES REF: 2022 CBC 11B-404.2.4 48 " M I N . C L R . 60 " M I N . C L R . AT EXTERIOR SIDE OF EXTERIOR DOORS 24" MIN. CLR. AT INTERIOR DOORS 18" MIN. CLR. 12" MIN. CLR. 12" CLR. 12" 60 INCHES DIAMETER SPACE MINIMUM CLEAR WIDTH T-SHAPED SPACE FOR 180 DEGREE TURNS 60" MIN. CLR. DIA. REF: 2022 CBC 11B-304 & 11B-403.5.1 36 " M I N . C L R . CL R . 24 " M I N . 60 " M I N . C L R . CONT. POINT 24" MAX. 32 " M I N . C L R . 36 " M I N . C L R . MIN. 30" X 48" CLEAR SPACE FOR FRONT APPROACH 27 " M I N . C L R . KN E E C L E A R A N C E 28 " T O 3 4 " M A X . TA B L E O R C O U N T E R H E I G H T 19" MIN. DEPTH KNEE/TOE CLEARANCE 4 8 " M I N . C L R . 30" MIN.CLR. NOTE: 1. THE REQUIRED CLEAR FLOOR SPACE MAY NOT OVERLAP THE REQUIRED KNEE SPACE BY MORE THAN 19". 2. KNEE CLEARANCES AT TABLES, COUNTERS & WORKSURFACES IS AT LEAST 27" HIGH, 30" WIDE AND 19" DEEP. NOTE: DOOR CLOSERS IF PRESENT, MUST BE SET SO THAT IT TAKES DOOR AT LEAST 5 SECONDS TO CLOSE FROM AN OPEN POSITION OF 90 DEGREES TO WITHIN 12° OF LATCH. THE FORCE TO OPEN DOOR SHALL NOT EXCEED 5 LBS. TYPICAL. DOOR CLOSERS ACCEPTABLE DOOR HARDWARE AND MOUNTING HEIGHTS PANIC LOOP LEVER 12.00° REF: 2022 CBC 11B-404.2 34 " - 4 4 " A . F . F . KICK PLATE NOTE: SWINGING DOOR & GATE SURFACES WITHIN 10" OF FINISH FLOOR SHALL HAVE A SMOOTH SURFACE OF THE PUSH SIDE EXTENDING THE FULL WIDTH OF DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS SHALL BE WITHIN 1/16" OF SURFACE & SHALL BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY KICK PLATES SHALL BE CAPPED. F.F. REF: 2022 CBC 11B-404.2.10 10 " M I N . 15 " M I N . 48 " M A X . 48 " M A X . 44 " M A X . 20" MAX. 20 < X ≤ 25 MAX. UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH REF: 2019 CBC 11B-308.2 15 " M I N . 48 " M A X . 48 " M A X . 46 " M A X . 10" MAX. 10 < X ≤ 24 MAX. UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH 10" MAX. 34 " M A X . 34 " M A X . REF: 2019 CBC 11B-308.3 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated A C C E S S I B I L I T Y D E T A I L S G-902 JH JR 6/20/24 JR SCALE: 3" = 1'-0"G-902 TOE & KNEE CLEARANCES33 SCALE: 1/2" = 1'-0"G-902 LATCH APPROACH CLEARANCES23 SCALE: 1/2" = 1'-0"G-902 HINGE APPROACH CLEARANCES32 SCALE: 1/2" = 1'-0"G-902 FRONT APPROACH CLEARANCES31 SCALE: 3/8" = 1'-0"G-902 TURNING SPACE22 SCALE: 3" = 1'-0"G-902 COUNTERTOP CLEARANCES21 SCALE: 1" = 1'-0"G-902 ACC. DOOR REQUIREMENTS11 SCALE: 1" = 1'-0"G-902 ACC. DOOR KICK PLATE12 SCALE: 1/2" = 1'-0"G-902 ACC. FORWARD REACH44 SCALE: 1/2" = 1'-0"G-902 ACC. SIDE REACH42 1 9/13/24 GRAPHICS Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 3/4 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide, except the letter "I," and the minimum spacing between letters shall be not less than 3/8 inch (9.5 mm). Signs larger than the minimum established in this section shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the means of exit sign illumination is or is not energized. If a chevron directional indicator is provided as part of the exit sign, the construction shall be such that the direction of the chevron directional indicator cannot be readily changed. 6" M I N H E I G H T 3/8" MIN. SPACING 3/4" MIN. STROKE (EXCEPT FOR LETTER "I") 2" MIN. LETTER WIDTH CBC 1013.6.1 INTERNALLY ILLUMINATED SIGNS Electrically powered, self-luminous and photoluminescent exit signs shall be listed and labeled in accordance with UL 924 and shall be installed in accordance with the manufacturer's instructions and Chapter 27. Exit signs shall be illuminated at all times. CBC 1013.5 EXTERNALLY ILLUMINATED EXIT SIGNS Externally illuminated exit signs shall comply with Sections 1013.6.1 through 1013.6.3. CBC 1013.6 WHERE REQUIRED Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. The path of egress travel to exits and within exits shall be marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs. Exit sign placement shall be such that any point in an exit access corridor or exit passageway is within 100 feet (30 480 mm) or the listed viewing distance of the sign, whichever is less, from the nearest visible exit sign. EXCEPTIONS: 1. Exit signs are not required in rooms or areas that require only one exit or exit access. 2. Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the building official. 3. Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1, R-2 or R-3 or R-3.1. 4. Exit signs are not required where inmates are housed, or held in dayrooms, sleeping rooms or dormitories in occupancies in Group I-3. 5. In occupancies in Groups A-4 and A-5, exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. CBC 1013.1 DIRECTIONAL CHEVRON SHALL NOT BE READILY CHANGED. REFER TO CODE PLAN FOR INDICATED DIRECTION ROOM ID DEPTH: RAISED 1/32" MIN. ABOVE BACKGROUND CHARACTERS: UPPERCASE, SANSERIF, NOT ITALIC, WIDTH OF "0" SHALL BE 60% MIN. TO 110% MAX. OF "1" HEIGHT: ROOM ID TEXT TO BE 1" HIGH, TYP. STROKE: THICKNESS OF "1" SHALL BE 15% MAX. OF HEIGHT 3/8" MIN., 1/2" MAX. CORRESPONDING GRADE II BRAILLE NOTE: PERMANENT SIGNAGE TO BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. MOUNTING LOCATION MUST ALLOW A PERSON TO APPROACH WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING PATH OF THE DOOR. 60 " M A X . 18 74 CHARACTER SPACING WIDTH MAX. RECTANGULAR 1/8" MIN. TO 4 TIMES STROKE STROKE WIDTH MAX. 1/16" MIN. TO 4 TIMES NON RECTANGULARRECTANGULAR ROOM 48 " M I N . 18" SQ. CLR. FLOOR AREA CENTERED ON SIGN & CLEAR OF DOOR SWING INSTALLATION, HEIGHT AND LOCATION RAISED CHARACTERS REF: 2019 CBC 11B-703 EXIT EXIT SIGNAGE 3/ 8 " M I N . DEPTH: RAISED 1/32" MIN. ABOVE BACKGROUND CHARACTERS: UPPERCASE, SANSERIF, NOT ITALIC, WIDTH OF "0" SHALL BE 60% MIN. TO 110% MAX. OF "1" HEIGHT: TEXT TO BE 1" HIGH, TYP. STROKE: THICKNESS OF "1" SHALL BE 15% MAX. OF HEIGHT 3/8" MIN., 1/2" MAX. 8" 4" 4" 6" NOTE : REFER TO SHEET A-601 AND DOOR SCHEDULE FOR ROOM SIGN DESIGNATIONS AND LOCATION SYMBOL PROPORTIONS FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL REF 11B-703.7.2.1 REF: CBC 1004.9 ALL TEXT/GRAPHICS TO BE A PERMANENT PART OF THE SIGN FOR ROOM SIGN REQUIREMENTS PLAN FOR LOCATION MAXIMUM OCCUPANCY 0' - 7 " 0' - 10" 59 0' - 1 " 0' - 1 " 0' - 0 1 / 2 " 1/2" RADIUS, TYP. 1" HIGH TEXT, CHARACTERS SPACED 1/2" APART 2" HIGH TEXT, VERIFY MESSAGE PRIOR TO FABRICATION C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated A C C E S S I B I L I T Y D E T A I L S G-903 JH JR 6/20/24 JR SCALE: 1" = 1'-0"G-903 ACC. ILLUMINATED EXIT SIGN14 SCALE: 3" = 1'-0"G-903 ACC. ROOM SIGNAGE12 SCALE: 3" = 1'-0"G-903 INTL SYMBOL OF ACC.22 SCALE: 3" = 1'-0"G-903 MAX. OCCUPANT LOAD23 9/13/24 NOTES: 1. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 2. THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN DETERMINING KNEE & TOE CLEARANCES. 3. SINK SHALL BE 6-1/2" DEEP MAX. 4. OPERABLE PARTS OF SOAP OR OTHER DISPENSERS LOCATED ON THE BACK WALL OF THE LAVATORY ARE WITHIN REACH RANGE 40Ffl MAXIMUM AFF AND 17fl-19fl MAXIMUM DEEP DEPENDENT UPON TOE CLEARANCE BELOW PER CBC. 5. DISPENSERS MOUNTED ON THE GRAB BAR SIDE OF ACCESSIBLE TOILET SHALL NOT PROJECT MORE THAN 3-1/2" FROM FACE OF WALL, NOR BE LOCATED CLOSER THAN 1-1/2" CLEAR OF BOTTOM OF GRAB BAR. FAUCET ACCESSIBILITY NOTES: (CONTROLS FOR FAUCETS SHALL COMPLY WITH CBC 11B-309) 1. FAUCETS CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. 2. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GRATER THAN 5 POUND FORCE (22.2N). LEVER- OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSINGVALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. P FF F I R E E X T I N G U I S H E R M FF J K ELEVATION 30" MIN 48 " M I N FORWARD APPROACH CLEAR FLOOR SPACE PLAN FLUSH VALVE TOP OF BOWL 13 1 / 2 M I N . MIRROR SEAT COVER DISPENSER SANITARY NAPKIN DISPENSER TOWEL DISPENSER ELECTRIC DRYER TRASH RECEPTACLE CUP DISPENSER P F.F. REF. 11B-603.3-.5 F E SIDE GRAB BAR TOILET PAPER DISP. C D1 12" MAX.42" MIN. IN FRONT OF TOILET 24" MIN. D2 54" MIN. A FINISHED WALL SIDE VIEW PLAN VIEW 30 " M I N . REQUIRED CLEAR SPACE F.O.F. 18" MIN. CLR. 48" MIN. G 9" MIN. CLR. TOE CLR. 6" MAX. 17" MIN. 8" MIN. KNEE CLR. REQUIRED CLEAR SPACE REMOVABLE CABINET FACE (WHERE OCCURS) H EXTEND FINISHED FLOOR TO WALL H *FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE (CBC 11B-606.3) REAR GRAB BAR 6"12"24" 36" MIN. G FINISHED WALL L FIRE EXTINGUISHER DRINKING FOUNTAIN DOOR-MOUNTED SIGNAGE (TYP.) PICTOGRAMS AND/OR LETTERING ARE NOT REQUIRED ON DOOR-MOUNTED SIGNAGE 12" 12" CL WOMEN MEN UNISEX 12" 12" DIAMETER CENTER LINE OF SIGN CENTER LINE OF DOOR AT EITHER SIDE WITHIN 1"12" MAX. 42" MIN. 54" MIN. 48" MIN. 18" MIN. 18" MIN 32" MIN CLR 60" MIN. 12" M AX 30"x48" CLEAR FLOOR LANDING 6 0 " M I N . C L R . 17" MIN.-18" MAX. FLUSH ACTIVATOR ON TRANSFER SIDE REF 2022 CBC 11B-604 19" MAX WALL FRAMING - REFER TO FLOOR PLAN FOR WALL TYPES WALL FINISH - REFER TO FINISH SCHEDULE CONCEALED FASTENERS. MIN. 6-# 10 WOOD SCREW WITH 1 1/2" PENETRATION INTO BLOCKING. 1 1/4" MIN. - 2" MAX. DIA. BLOCKING IN WALL 1 1/2" 12" MIN. TO PROJECTION ABOVE (1/ 1/2" FOR SHOWER CONTROLS OR GRAB BARS.) 1 1/2" MIN TO PROJECTION BELOW SEOR PROVIDE CALCS. TO JUSTIFY ALL COMPONENTS AND CONNECTIONS IN THIS DETAIL. PENETRATION 0' - 1 1/2" 1" MIN. 2 1/4" WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR CLEAR OF DOOR SWING. MOUNT AT 48" MIN AND 60" MAX FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. DOOR-MOUNTED SIGNAGE WITHIN 1" OF CENTERLINE OF DOOR LETTERING RAISED 1/32" MIN. UPPERCASE SANS SERIF CHARACTERS HEIGHT OF LETTERING 5/8" MIN. TO 2" MAX. RESTROOM 3/8" MIN., 1/2" MAX.CORRESPONDING GRADE II BRAILLE ROOM IDENTIFICATION SIGN REFER TO ROOM ID SIGN DETAIL REF. 11B-703.7.2.6 58" MIN- 60" MAX UNISEX RESTROOM 60" MAX. WALL SIGNAGE DOOR-MOUNTED GEOMETRIC SYMBOLS FOR ADDITIONAL GEOMETRIC SYMBOL INFORMATION REF. TO: 12/G-904 FOR ADDITIONAL ROOM ID SIGN INFORMATION REF. TO: 12/G-903 A TOILET CL FROM WALL 17"-18"L LOW DRINKING FOUNTAIN APPROACH PER 11B-306 B TOILET SEAT HEIGHT 17"-19"SPOUT HEIGHT AND LOCATION FROM EDGE OF UNIT INCLUDING BUMPERS 36" MAX. A.F.F & 5" MAX. FROM FRONT EDGE OF UNIT C TOP OF GRAB BAR GRIPPING SURFACE 33"-36"DRINKING FOUNTAIN OPERABLE PARTS FROM FRONT EDGE OF THE UNIT 6" MAX. D1 FURTHEST TOILET PAPER IN FRONT OF TOILET 7"-9" AT CL M DRINKING FOUNTAIN KNEE CLEARANCE 27" MIN. CLR. D2 DISPENSER HEIGHT 19"-24" E SANITARY NAPKIN DISPOSAL (HIGHEST OPERABLE PART A.F.F.) 19" MIN.P DISPENSERS/OPERABLE PARTS 40" MAX. F MIRROR - BOT. OF REFLECTIVE SURFACE A.F.F. 40" MAX. WHEN ABOVE SINK OR COUNTERTOP 35" MAX. NO LAV. Q REACH RANGE - FRONT & SIDE APPROACH 48" MAX. G LAVATORY/SINK RIM HEIGHT 34" MAX.R BOTTOM OF OPENING/OUTLET 19" MIN. H LAVATORY KNEE CLEARANCE 17" MIN. AT 8" DEPTH 29" MIN. AT APRON S TOE CLEARANCE AT TOILET PARTITION 9" MIN. J URINAL LIP HEIGHT 17" MAX.T TOILET FLUSH CONTROL HEIGHT K URINAL FLUSH HANDLE HEIGHT 44" MAX. STANDARD HEIGHT FOUNTAIN ACCESSIBLE FOUNTAIN THE SPOUT SHALL PROVIDE A FLOW OF WATER 2" HIGH MIN. AND SHALL BE LOCATED 5" MAX. FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 2 INCHES FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 30 DEGREES MAX. WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES AND 5 INCHES MAX. FROM THE FRONT ON THE UNIT THE ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAX. 36 " M A X . 18" MIN. CLR. 5" MAX. 19" MAX.15" MIN OPERABLE PARTS SHALL COMPLY WITH 11B-309 THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM. FRONT MOUNTED OR SIDE MOUNTED & LOCATED WITHIN 6" OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE. 38 " M I N . 4 3 " M A X . -TOE AND KNEE CLEARANCE SHALL BE PROVIDED AS PER 11B 306.3 SEE DETAIL REF 11B 602 -MOUNTING SHALL BE PER MANUF. INTO SOLID BACKING PLATE ACCESSIBLE BOTTLE FILLER WHERE OCCURS. REFER TO DETAIL REF. TO: 42 / G-904 32" MIN. CLR. 36" MIN. IF ALCOVE DEPTH IS >24" 18" MIN ACCESSIBLE WATER FILLER STATION OPERABLE PARTS SHALL COMPLY WITH 11B-309 THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM. FRONT MOUNTED OR SIDE MOUNTED & LOCATED WITHIN 6" OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE. REF 11B 602 -MOUNTING SHALL BE PER MANUFACTURER INTO SOLID BACKING PLATE 4" MAX. 30" MIN. CLR. FOR FRONT APPROACH 48 " M A X . T O S E N S O R EQ EQ CL 4 8 " M I N . C L R . F O R F R O N T A P P R O A C H C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated A C C E S S I B I L I T Y D E T A I L S G-904 JH JR 6/20/24 JR SCALE: 1/2" = 1'-0"G-904 FIXTURE AND ACCESSORIES MOUNTING HEIGHTS AND CLEARANCES51 SCALE: 1 1/2" = 1'-0"G-904 RESTROOM GEOMETRIC SYMBOLS12 SCALE: 1/2" = 1'-0"G-904 ACC. SINGLE ACCOMODATION TOILET31 SCALE: 3" = 1'-0"G-904 ACC. GRAB BAR ATTACHMENT21 SCALE: 1" = 1'-0"G-904 RESTROOM SIGNAGE22 1 SCALE: 3" = 1'-0"G-904 HI-LO DRINKING FOUNTAIN32 SCALE: 3" = 1'-0"G-904 WATER BOTTLE FILLER STATION42 9/13/24 13064 242.79 bld cor 13065 242.81 bld cor E V E V E V HOSE BIB PF SITE PLAN LEGEND EXISTING CONCRETE PAVING EXISTING PLANTING AREA STANDARD ACCESSIBLE STALL ELECTRICAL VEHICLE CHARGING STALLEV VAN ACCESSIBLE STALLVAN ACCESSIBLE PATH OF TRAVEL (SHALL BE 48" MIN. CBC 11B-403.5) EASTMENT SETBACK PROPERTY LINE BUILDING FOOTPRINT 1106 WALNUT (EXISTING) EXISTING 10,921 SF (NO CHANGE) VB CONSTRUCTION TYPE 2 STORIES EXISTING PARKING NO NEW WORK EXISTING PARKING NO NEW WORK 02 4013.M 02 4013.BE 02 4013.BF 02 4013.BG 02 4013.U 45' - 1" EXISTING PARKING NO NEW WORK 1 02 4013.U 1 EXTERIOR AREA OF ASSISTED RESCUE PER 1009.7, NO SEPARATION REQUIRED PER 1009.7.2 EXCEPTION. FENCE/GATE PROJECT UNDER SEPARATE PERMIT, SHOWN FOR REFERENCE ONLY 105' - 0" 35' - 2" 70' - 8" 30' - 8" 1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated AR C H I T E C T U R A L S I T E P L A N AS-101 JH JR 6/20/24 JR KEYNOTES 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS 2. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION. 3. REFER TO ELECTRICAL PLANS FOR FURTHER IINFORMATION. 4. ALL SIDEWALKS, CROSSWALKS, COMMON AREAS AND BUILDING ENTRANCES SHALL BE ACCESSIBLE AND IN COMPLIANCE WITH 2022 CBC 11B. A. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. B. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE <1/2". C. VERTICAL CHANGES IN LEVEL SHALL NOT EXCEED 1/4". D. THE CLEAR WIDTH FOR SIDEWALKS AND WALKS SHALL BE 48" MIN. 5. ALL CURBING NOT WITHIN A PARKING SPACE SHALL BE PAINTED RED TO DESIGNATE THE FIRE LANES SITE PLAN GENERAL NOTES SCALE: 1/16" = 1'-0"AS-101 SITE PLAN1 W A L N U T S T . SANTA ROSA ST. 02 4013.BE EXISTING ACCESSIBLE PARKING TO REMAIN. 02 4013.BF EXISTING DRIVE APPROACH TO REMAIN. 02 4013.BG EXISTING CURB AND GUTTER. 02 4013.M EXISTING CURB RAMP TO REMAIN. 02 4013.U EXISTING ACCESSIBLE PATH OF TRAVEL TO REMAIN REQUIRED PARKING FUNCTION AREA MIN. REQUIRED PER.... TOTAL PARKING REQ'D TOTAL PARKING PROVIDED OFFICE 9,633 1 PER 300 S.F. 33 34 9/13/24 EXISTING STUD FRAMED WALL, TO REMAIN WALL TYPES LEGEND A1 A2 EXISTING WALL FURRING, TO REMAINA3 EXISTING MASONRY BLOCK WALL, TO REMAINA4 EXISTING CONCRETE WALL, TO REMAINA5 EXISTING STOREFRONT WALL, TO REMAINA6 NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP. BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS A7 EXISTING MASONRY BLOCK WALL, TO REMAIN 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 BUREAU SERGEANT 107 MEETING 125 OFFICE 124 DRONE/EQUIP. STORAGE 105 DETECTIVE EQUIPMENT 106 ELECTRICAL 120 WOMEN 119 MEN 118 HALL 114 JAN. 117 HALL 115 STORAGE 111 STAIR 122 STAIR 123 BRIEFING ROOM 122 HALL 139 LOBBY 100 ELEV. 127 SHARED OFFICE 126 A5 A7 A7 A7A7 A7 A7 A2 A3 A2 A2 02 4116.BD 02 4116.J A2 02 4116.C 02 4116.D A-401 1 02 4116.CJ 1 02 4116.AS 02 4116.AR 02 4116.CJ DEMO - INTERIOR - CARPET DEMO EXISTING PARTITION OR WALL FINISH DEMO - INTERIOR - LINOLEUM TILE DEMO - INTERIOR - TILE INTERIOR - CARPET - TO REMAIN NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS A-501 & A-502 FOR ADDTIONAL INFORMATION. DEMO - INTERIOR - LVT C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DE M O L I T I O N F I R S T F L O O R P L A N AD-101 JH JR 6/20/24 JR KEYNOTES 02 4116.AR PORTION OF EXISTING WALL TO BE REMOVED FOR NEW DOOR OPENING. 02 4116.AS PREPARE EXISTING OPENING FOR NEW STUD WALL INFILL. 02 4116.BD EXISTING LIGHT GUAGE METAL STUD WALL TO BE REMOVED. 02 4116.C EXISTING CASEWORK TO BE REMOVED 02 4116.CJ EXISTING STOREFRONT TO BE REMOVED AND DISCARDED. 02 4116.D EXISTING COUNTERTOP AND CASEWORK TO BE REMOVED 02 4116.J EXISTING SINK TO BE REMOVED. PROTECT IN PLACE EXISTING PLUMBING FOR NEW DRINKING FOUNTAIN AND BOTTLE FILLER. REFER TO PLUMBING FOR ADDITIONAL INFORMATION. 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. FLOOR PLAN GENERAL NOTES 2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED. 3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER INFORMATION. 4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF PROVIDED. 5. NOT USED 6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES. 8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC HEIGHT LIMITATIONS 9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS 10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING 11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE BARRIERS 12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED 13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS, PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING SCALE: 3/16" = 1'-0"AD-101 DEMOLITION FIRST FLOOR PLAN1 FLOOR DEMOLITION LEGEND 1 1 9/13/24 UP EXISTING STUD FRAMED WALL, TO REMAIN WALL TYPES LEGEND A1 A2 EXISTING WALL FURRING, TO REMAINA3 EXISTING MASONRY BLOCK WALL, TO REMAINA4 EXISTING CONCRETE WALL, TO REMAINA5 EXISTING STOREFRONT WALL, TO REMAINA6 NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP. BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS A7 EXISTING MASONRY BLOCK WALL, TO REMAIN 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 A2 A7 A7 A7 A2 A2 A2 A2 A2 A7 02 4116.CI 02 4116.CA 02 4116.CA A-401 2 02 4013.AH 02 4013.AH 02 4116.A 02 4116.D 1 1 02 4116.CP 1 DEMO - INTERIOR - CARPET DEMO EXISTING PARTITION OR WALL FINISH DEMO - INTERIOR - LINOLEUM TILE DEMO - INTERIOR - TILE INTERIOR - CARPET - TO REMAIN NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS A-501 & A-502 FOR ADDTIONAL INFORMATION. DEMO - INTERIOR - LVT C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DE M O L I T I O N S E C O N D F L O O R P L A N AD-102 JH JR 6/20/24 JR KEYNOTES 02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE. 02 4116.A EXISTING PLUMBING FIXTURE TO BE REMOVED 02 4116.CA DEMO EXISTING GYP. BD. COLUMN WRAP TO PREPARE FOR NEW WALLS. 02 4116.CI EXISTING MOTORIZED PROJECTOR SCREEN TO BE REMOVED, SET ASIDE, AND PROTECTED FOR INSTALLATION IN CONFERENCE ROOM. SEE PROPOSED PLANS. 02 4116.CP REMOVE EXISTING FIRE EXTINGUISHER CABINET, PREPARE OPENING FOR NEW CABINET 02 4116.D EXISTING COUNTERTOP AND CASEWORK TO BE REMOVED 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. FLOOR PLAN GENERAL NOTES 2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED. 3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER INFORMATION. 4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF PROVIDED. 5. NOT USED 6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES. 8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC HEIGHT LIMITATIONS 9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS 10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING 11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE BARRIERS 12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED 13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS, PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING SCALE: 3/16" = 1'-0"AD-102 DEMOLITION SECOND FLOOR PLAN1 FLOOR MATERIALS LEGEND 9/13/24 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 MEETING 125 OFFICE 124 BUREAU SERGEANT 107 DRONE/EQUIP. STORAGE 105 DETECTIVE EQUIPMENT 106 ELECTRICAL 120 WOMEN 119 MEN 118 HALL 114 JAN. 117 HALL 115 STORAGE 111 STAIR 122 STAIR 123 BRIEFING ROOM 122 HALL 139 LOBBY 100 ELEV. 127 SHARED OFFICE 126 8' - 0" 8' - 0" 02 4013.BH 02 4013.AH 02 4116.AC 02 4116.AC 02 4116.CD 02 4013.BI 02 4116.AM 02 4116.AC 02 4116.AM 02 4116.CJ 02 4116.I 02 4116.CD 02 4013.BI02 4116.AB 02 4116.AB 02 4116.AD 02 4013.BI 02 4116.AF 02 4116.AB 02 4116.BA CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X" LEGEND LIGHT FIXTURE, REFER TO ELECTRICAL PLANS MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS INTERIOR - GYPSUM BOARD CEILING OVER NEW 2X FRAMING INTERIOR - ACOUSTIC CEILING TILE REUSE OR MATCH EXISTING TILE AND GRID CEILING ACCESS PANEL DEMOLISHED OBJECTS MATERIAL TAG REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION DEMO - INTERIOR - GYPSUM BOARD CEILING SEE KEYNOTE DEMO - INTERIOR - ACOUSTICAL CEILING TILE SEE KEYNOTE EXTERIOR - (E) SOFFIT TO REMAIN ACT-1 ACT-1 GWB-1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DE M O L I T I O N R E F L E C T E D C E I L I N G P L A N - F I R S T F L O O R AD-111 JH JR 6/20/24 JR SCALE: 3/16" = 1'-0"AD-111 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR 1 KEYNOTES 1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION. 4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES. 5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED CEILING PLAN, UNO. 6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED INCLUDING POP RIVETS AND TAPPETS. 7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS 8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH CEILING 9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE VERTICAL STRUTS RCP GENERAL NOTES 10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION. 11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA. REFER TO SPECS FOR SHADE CLOTH 02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE. 02 4013.BH EXISTING SOFFIT DROP TO REMAIN. 02 4013.BI EXISTING LIGHT FIXTURE TO BE RELOCATED. REFER TO ELECTRICAL. 02 4116.AB PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR NEW WALL INSTALLATION, SET ASIDE GRID AND TILE FOR POTENTIAL REUSE. 02 4116.AC DEMOLISH GRID, REMOVE AND SET ASIDE TILE FOR POTENTIAL RESUSE. 02 4116.AD PARTIALLY REMOVE SOFFIT AS NEEDED FOR NEW WALL INSTALLATION. 02 4116.AF MODIFY SOFFIT AS NEEDED FOR PROPOSED SOFFIT EXTENSION. 02 4116.AM EXISTING LIGHT FIXTURE TO BE REMOVED AND DISCAREDED. REFER TO ELECTRICAL. 02 4116.BA PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR RECESSED PROJECTION SCREEN INSTALLATION, SET ASIDE GRID AND TILE FOR POTENTIAL REUSE. 02 4116.CD EXISTING DIFFUSER TO BE REMOVED AND DISCARDED. REFER TO MECHANICAL. 02 4116.CJ EXISTING STOREFRONT TO BE REMOVED AND DISCARDED. 02 4116.I EXISTING WALL TO BE REMOVED. 9/13/24 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 ADMIN 214A DEPT. CHIEF 213 CHIEF 214C STAIRS 144 INT AFFAIRS LIEUT. 224 BREAK ROOM 207 BOS. MANAGER 206 PUBLIC AFFAIRS MANAGER 205 BREAK ROOM 215 SERVER 216 WOMENS 222 MENS 129MEETING ROOM 202 ELEVATOR 131 COPY ROOM 210 ELEV MECH 112 DEPT. CHIEF 211 CRIME ANALYST 209 TRAIN/HIRING MANAGER 208 EQUIP. 220 1275 SF CONF. 202 HALL 149 02 4013.AH 02 4116.AC 02 4116.AM 02 4116.AM 02 4116.AB 02 4116.AB 02 4116.CD02 4013.BI 02 4116.AB 02 4116.AB 02 4116.AH 02 4116.CD 02 4116.CD 02 4116.CD 02 4116.BA 02 4116.AB 02 4013.AH CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X" LEGEND LIGHT FIXTURE, REFER TO ELECTRICAL PLANS MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS INTERIOR - GYPSUM BOARD CEILING OVER NEW 2X FRAMING INTERIOR - ACOUSTIC CEILING TILE REUSE OR MATCH EXISTING TILE AND GRID CEILING ACCESS PANEL DEMOLISHED OBJECTS MATERIAL TAG REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION DEMO - INTERIOR - GYPSUM BOARD CEILING SEE KEYNOTE DEMO - INTERIOR - ACOUSTICAL CEILING TILE SEE KEYNOTE EXTERIOR - (E) SOFFIT TO REMAIN ACT-1 ACT-1 GWB-1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DE M O L I T I O N R E F L E C T E D C E I L I N G P L A N - S E C O N D F L O O R AD-112 JH JR 6/20/24 JR SCALE: 3/16" = 1'-0"AD-112 DEMOLITION REFLECTED CEILING PLAN - SECOND FLOOR 1 KEYNOTES 1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION. 4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES. 5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED CEILING PLAN, UNO. 6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED INCLUDING POP RIVETS AND TAPPETS. 7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS 8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH CEILING 9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE VERTICAL STRUTS RCP GENERAL NOTES 10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION. 11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA. REFER TO SPECS FOR SHADE CLOTH 02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE. 02 4013.BI EXISTING LIGHT FIXTURE TO BE RELOCATED. REFER TO ELECTRICAL. 02 4116.AB PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR NEW WALL INSTALLATION, SET ASIDE GRID AND TILE FOR POTENTIAL REUSE. 02 4116.AC DEMOLISH GRID, REMOVE AND SET ASIDE TILE FOR POTENTIAL RESUSE. 02 4116.AH MODIFY EXISTING ACT CEILING AS NEEDED FOR REMOVAL OF RECESSED PROJECTOR SCREEN. 02 4116.AM EXISTING LIGHT FIXTURE TO BE REMOVED AND DISCAREDED. REFER TO ELECTRICAL. 02 4116.BA PARTIALLY REMOVE GRID AND TILE AS NEEDED FOR RECESSED PROJECTION SCREEN INSTALLATION, SET ASIDE GRID AND TILE FOR POTENTIAL REUSE. 02 4116.CD EXISTING DIFFUSER TO BE REMOVED AND DISCARDED. REFER TO MECHANICAL. 9/13/24 PF EXISTING STUD FRAMED WALL, TO REMAIN WALL TYPES LEGEND A1 A2 EXISTING WALL FURRING, TO REMAINA3 EXISTING MASONRY BLOCK WALL, TO REMAINA4 EXISTING CONCRETE WALL, TO REMAINA5 EXISTING STOREFRONT WALL, TO REMAINA6 NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP. BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS A7 EXISTING MASONRY BLOCK WALL, TO REMAIN 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 BUREAU SERGEANT 107 MEETING 125 OFFICE 124 DRONE/EQUIP. STORAGE 105 DETECTIVE EQUIPMENT 106 ELECTRICAL 120 WOMEN 119 MEN 118 HALL 114 JAN. 117 HALL 115 STORAGE 111 STAIR 122 STAIR 123 BRIEFING ROOM 122 HALL 139 LOBBY 100 ELEV. 127 SHARED OFFICE 126 A5 A7 A7 A7A7 A7 A7 A1 A1 A2 A3 A2 A2 3 A-200 27 0000.B 27 0000.B 27 0000.B 27 0000.B 08 4313.A 08 4313.A 08 4313.A A2 A-412 4 S-1 S-1S-1S-1S-1 A-601 1 A-601 2 A-401 4 A-412 3 A-412 2 1 111B STORAGE 133 A-4111W A-411 2N 1N 1E 1S 2W 2S 2E 122A S-2 S-2 122B OPEN OFFICE 102 INCIDENT COM. 123 BREAK ROOM 121 02 4013.A 114A1 A-601 3 S-3 5 9' - 1" AL I G N 2' - 2 " ALIGN ALIGN 15' - 5" A-601 4 A-413 1 2 A1 V.I.F. 7' - 10" V.I.F. 3' - 3" V.I.F. 1' - 3" V.I.F. 6' - 6" V.I.F. 1' - 2" V.I.F. 6' - 6" V.I.F. 9" V.I.F. 3' - 4" V.I.F. 1' - 5" V.I.F. 9' - 11" 1 1 1' - 0 " E111A 10 5100.E 1 1 1 126 100A C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated PR O P O S E D F I R S T F L O O R P L A N A-101 JH JR 6/20/24 JR KEYNOTES 02 4013.A EXISTING STOREFRONT TO REMAIN. PROTECT IN PLACE 08 4313.A ALUMINUM STOREFRONT SYSTEM - REFER TO SCHEDULES. 10 5100.E 15"W X 18" D PERSONAL STORAGE LOCKER 27 0000.B WALL MOUNTED TV, BY OWNER 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. FLOOR PLAN GENERAL NOTES 2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED. 3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER INFORMATION. 4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF PROVIDED. 5. NOT USED 6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES. 8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC HEIGHT LIMITATIONS 9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS 10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING 11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE BARRIERS 12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED 13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS, PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING SCALE: 3/16" = 1'-0"A-101 FIRST FLOOR PLAN1 1 9/13/24 UP UP EXISTING STUD FRAMED WALL, TO REMAIN WALL TYPES LEGEND A1 A2 EXISTING WALL FURRING, TO REMAINA3 EXISTING MASONRY BLOCK WALL, TO REMAINA4 EXISTING CONCRETE WALL, TO REMAINA5 EXISTING STOREFRONT WALL, TO REMAINA6 NEW 3-5/8" STEEL STUD FRAMED INTERIOR PARTITION W/ 5/8" GYP. BOARD EACH SIDE, ACOUSTIC BATT INSULATION, SEE A-902 FOR DETAILS A7 EXISTING MASONRY BLOCK WALL, TO REMAIN 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 BREAK ROOM 215 SERVER 216 WOMENS 222 MENS 129MEETING ROOM 202 ELEVATOR 131 COPY ROOM 210 ELEV MECH 112 DEPT. CHIEF 211 CRIME ANALYST 209 TRAIN/HIRING MANAGER 208 EQUIP. 220 ADMIN 214A DEPT. CHIEF 213 INT AFFAIRS LIEUT. 224 BREAK ROOM 207 BOS. MANAGER 206 PUBLIC AFFAIRS MANAGER 205 HALL 149 JAN. 223 CONF. 202 STAIRS 152 STAIRS 144 JAN. 216 CHIEF 214C A1 A1A2 A2 A-401 3 3 A-200 27 0000.B 27 0000.B 27 0000.B 11 5213.B 27 0000.B 214 A-411 4E4W 4N 4S E222 224 5' - 6" 5' - 6" A1 MA T C H E X . C O L U M N W I D T H MA T C H E X . C O L U M N W I D T H 27 0000.B 13' - 2" EQ.EQ. EQ.EQ. 02 4013.AH A1 A-413 3 4 A1 10 4400.E 10 4400.C 1 1 1 CLR 5' - 1 1/2" A2 3' - 1" C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated PR O P O S E D S E C O N D F L O O R P L A N A-102 JH JR 6/20/24 JR KEYNOTES 02 4013.AH EXISTING COLUMN TO REMAIN. PROTECT IN PLACE. 10 4400.C SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH EXTINGUISHER, 2A:10B:C RATING ; REFER TO 7/A-903 10 4400.E PROVIDE NEW FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER AT EXISTING LOCATION 11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER, COORDINATE POCKET INSTALLATION WITH CEILING 27 0000.B WALL MOUNTED TV, BY OWNER 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. FLOOR PLAN GENERAL NOTES 2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED. 3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER INFORMATION. 4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF PROVIDED. 5. NOT USED 6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES. 8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC HEIGHT LIMITATIONS 9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS 10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING 11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE BARRIERS 12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED 13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS, PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING SCALE: 3/16" = 1'-0"A-102 SECOND FLOOR PLAN1 1 9/13/24 CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X" LEGEND LIGHT FIXTURE, REFER TO ELECTRICAL PLANS MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS INTERIOR - GYPSUM BOARD CEILING OVER NEW 2X FRAMING INTERIOR - ACOUSTIC CEILING TILE REUSE OR MATCH EXISTING TILE AND GRID CEILING ACCESS PANEL DEMOLISHED OBJECTS MATERIAL TAG REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION DEMO - INTERIOR - GYPSUM BOARD CEILING SEE KEYNOTE DEMO - INTERIOR - ACOUSTICAL CEILING TILE SEE KEYNOTE EXTERIOR - (E) SOFFIT TO REMAIN ACT-1 ACT-1 GWB-1 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 09 2116.C 09 2116.C 09 5100.A 09 2116.H 10 A-902 09 2116.D 02 4013.BJ 02 4013.BJ 9' - 0" 8' - 5" MEETING 125 OFFICE 124 BUREAU SERGEANT 107 DRONE/EQUIP. STORAGE 105 DETECTIVE EQUIPMENT 106 ELECTRICAL 120 WOMEN 119 MEN 118 HALL 114 JAN. 117 HALL 115 STORAGE 111 STAIR 122 STAIR 123 BRIEFING ROOM 122 HALL 139 LOBBY 100 ELEV. 127 SHARED OFFICE 126 STORAGE 133 OPEN OFFICE 102 INCIDENT COM. 123 BREAK ROOM 121 2' - 0"2' - 0" 09 2116.D 02 4013.BH 26 5000.A 26 5000.A 26 5000.A 26 0000.A 09 5100.H 8' - 0" 8' - 0" 23 0000.F 23 0000.F VIF 09 2116.D EQ EQ EQ E Q EQ EQ EQ EQ 11 5213.B EQ EQ 09 5100.H 1 11' - 2 3/4"12' - 2" 09 5100.H 12 A-902 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated RE F L E C T E D C E I L I N G P L A N - F I R S T F L O O R A-111 JH JR 6/20/24 JR KEYNOTES 02 4013.BH EXISTING SOFFIT DROP TO REMAIN. 02 4013.BJ EXISTING BULKHEAD TO REMAIN. 09 2116.C GYPSUM BOARD CEILING ASSEMBLY 09 2116.D GYPSUM BOARD SOFFIT & FRAMING 09 2116.H NEW INTERIOR WALL TO DIE INTO BOTTOM OF SOFFIT. REPAIR SOFFIT AROUND NEW WALL AS REQUIED. 09 5100.A ACOUSTICAL LAY-IN TILE CEILING 09 5100.H ACOUSTICAL CEILING TILE & GRID TO MATCH EXISTING OR REUSE GOOD CONDITION SET ASIDE EXISTING TILE AND GRID 11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER, COORDINATE POCKET INSTALLATION WITH CEILING 23 0000.F EXHAUST FAN - REFER TO MECHANICAL 26 0000.A NEW ILLUMINATED EXIT SIGN. 26 5000.A LIGHT FIXTURE. REFER TO ELECTRICAL 1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION. 4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES. 5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED CEILING PLAN, UNO. 6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED INCLUDING POP RIVETS AND TAPPETS. 7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS 8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH CEILING 9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE VERTICAL STRUTS RCP GENERAL NOTES 10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION. 11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA. REFER TO SPECS FOR SHADE CLOTH SCALE: 3/16" = 1'-0"A-111 REFLECTED CEILING PLAN - FIRST FLOOR 1 1 9/13/24 CEILING HEIGHT (SEE PLAN FOR ACTUAL HEIGHTS)XX'-X" LEGEND LIGHT FIXTURE, REFER TO ELECTRICAL PLANS MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS INTERIOR - GYPSUM BOARD CEILING OVER NEW 2X FRAMING INTERIOR - ACOUSTIC CEILING TILE REUSE OR MATCH EXISTING TILE AND GRID CEILING ACCESS PANEL DEMOLISHED OBJECTS MATERIAL TAG REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION DEMO - INTERIOR - GYPSUM BOARD CEILING SEE KEYNOTE DEMO - INTERIOR - ACOUSTICAL CEILING TILE SEE KEYNOTE EXTERIOR - (E) SOFFIT TO REMAIN ACT-1 ACT-1 GWB-1 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 ADMIN 214A DEPT. CHIEF 213 CHIEF 214C STAIRS 144 INT AFFAIRS LIEUT. 224 BREAK ROOM 207 BOS. MANAGER 206 PUBLIC AFFAIRS MANAGER 205 BREAK ROOM 215 SERVER 216 WOMENS 222 MENS 129 MEETING ROOM 202 ELEVATOR 131 COPY ROOM 210 ELEV MECH 112 DEPT. CHIEF 211 CRIME ANALYST 209 TRAIN/HIRING MANAGER 208 EQUIP. 220 1275 SF CONF. 202 HALL 149 09 5100.H 09 5100.H 09 5100.H 26 5000.F 09 5100.H 26 5000.A 09 5100.H 09 5100.H 23 0000.A 23 0000.F 26 5000.A 8' - 6" 8' - 6" 23 0000.F 23 0000.A 11 5213.B EQ E Q EQ EQ EQ EQ EQ E Q 6' - 0" EQ EQ 7' - 0" EQ 4' - 0 " E Q 09 5100.H 09 5100.H 1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated RE F L E C T E D C E I L I N G P L A N - S E C O N D F L O O R A-112 JH JR 6/20/24 JR KEYNOTES 09 5100.H ACOUSTICAL CEILING TILE & GRID TO MATCH EXISTING OR REUSE GOOD CONDITION SET ASIDE EXISTING TILE AND GRID 11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER, COORDINATE POCKET INSTALLATION WITH CEILING 23 0000.A MECHANICAL EQUIPMENT. REFER TO MECHANICAL 23 0000.F EXHAUST FAN - REFER TO MECHANICAL 26 5000.A LIGHT FIXTURE. REFER TO ELECTRICAL 26 5000.F NEW LOCATION OF LIGHT FIXTURE. REFER TO ELECTRICAL. 1. REFER TO GENERAL NOTES SHEET G-100 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION. 4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES. 5. HEIGHT OF CEILINGS SHALL BE MEASURED FROM TOP OF SLAB TO FINISH FACE OF GWB OR FACE OF CEILING GRID AS INDICATED ON THE REFLECTED CEILING PLAN, UNO. 6. BORDERS AT LAY-IN ACOUSTICAL CEILING PANELS SHALL BE CUT TO MATCH FACTORY EDGE PROFILE. NO EXPOSED FASTENERS SHALL BE PERMITTED INCLUDING POP RIVETS AND TAPPETS. 7. CONTRACTOR TO VERIFY DEPTH OF SOFFITS AND HOLD TIGHT TO PLUMBING, SPRINKLERS, ELECTRICAL AND MECHANICAL DUCTS 8. SEE MECHANICAL DRAWINGS FOR MECH. ACCESS PANELS. PAINT TO MATCH CEILING 9. AT DROPPED GWB SOFFITS/GWB BEAMS, PROVIDE C-STUDS AS VERTICAL SUPPORTS AT EACH SIDE OF THE SOFFIT/BEAM AND DIAGONAL BRACING FOR WRACKING. IF CEILING JOIST SPACING DIFFERS FROM FLOOR THEN BLOCKING BETWEEN THE FLOOR FRAMING MAY BE UTILIZED TO ATTACH THE VERTICAL STRUTS RCP GENERAL NOTES 10. ALL LIGHT FIXTURES ARE TO BE INSTALLED ACCORDING TO THE ARCHITECTURAL REFLECTED CEILING PLAN. ARCHITECT TO REVIEW CEILING LAYOUT INCLUDING BULKHEADS AND GRID PRIOR TO INSTALLATION. 11. PROVIDE NEW ROLLER SHADES AT ALL EXTERIOR WINDOWS EXCLUDING ENTRANCE VESTIBULE AND SOUTH STAIR. SINGLE ROLLER W/ FASCIA. REFER TO SPECS FOR SHADE CLOTH SCALE: 3/16" = 1'-0"A-112 REFLECTED CEILING PLAN - SECOND FLOOR 1 9/13/24 LEGEND (E) DECK. (E) SINGLE PLY ROOFING SYSTEM 1 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 02 4013.E 02 4013.E 02 4013.F TYP. 02 4013.AE TYP. 02 4013.AC TYP. 02 4013.AC 23 0000.A 02 4013.AE 1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated RO O F P L A N A-120 JH JR 6/20/24 JR KEYNOTES 02 4013.AC EXISTING LOW-SLOPE SINGLE-PLY ROOF TO REMAIN. 02 4013.AE EXISTING PARAPET CAP TO REMAIN. 02 4013.E EXISTING MECHANICAL UNIT TO REMAIN 02 4013.F EXISTING ROOF HATCH TO REMAIN 23 0000.A MECHANICAL EQUIPMENT. REFER TO MECHANICAL 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS 2. REFER TO MECHANICAL PLANS FOR ROOF MOUNTED EQUIPMENT LOCATIONS AND TYPES. 3. REFER TO ELECTRICAL PLANS FOR POWER DISTRIBUTION TO ROOF MOUNTED EQUIPMENT. 4. ALL ROOFING MATERIALS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ROOF PLAN GENERAL NOTES SCALE: 3/16" = 1'-0"A-120 ROOF PLAN1 9/13/24 1 18316910 26 0000.L C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 1/8" = 1'-0" EX T E R I O R E L E V A T I O N S A-200 JH JR 6/20/24 JR 26 0000.L EXISTING ILLUMINATED SIGNAGE CABINET TO REMAIN. NEW ARTWORK PROVIDED BY OWNER UNDER SEPARATE PERMIT. SCALE: 1/8" = 1'-0"A-101 A-200 WEST ELEVATION3 KEYNOTES 1 9/13/24 TYP. 10 2800.Q 10 2113.A WOMENS 222 MENS 129 A-411 4E A-411 3S 3N 3W 3E 4W 4N 4S 48" MIN. CLR. 48" MIN.CLR. E222 60" MIN. CLR. 10 2113.A 30 " X 4 8 " CL R . 30 " X 4 8 " CL R . 10 2800.B 10 2800.B 10 2800.B 10 2800.B 30 " X 4 8 " C L R . 10 2800.F 10 2800.F 10 2800.F 10 2800.C 10 2800.C 10 2800.C JAN. 223 44" MIN CLR 22 0000.R TYP. 22 0000.R 37"59" 1 1' - 6" 1 10 2800.G 22 0000.T 1' - 1"1' - 4"1' - 6 1/2" 6' - 9" 22 0000.Q T-SHAPED TURNING SPACE PER 11B-304.3.2, KNEE CLEARANCE PROVIDED AT ACCESSIBLE LAV. 10 2113.C 10 2113.B TYP. 10 2800.Q 10 2113.C 22 0000.Q02 4116.A TYP. 10 2113.A VIF 2' - 10" 1" VIF 2' - 10" VIF 5' - 4" 10 2800.G VIF 2' - 8" 5' - 0" CLR A-4111W A-411 2N 1N 1E 1S 2W 2S 2E MEN 118 WOMEN 119 TYP. 10 2800.Q 30"X48" CLR. 30"X48" CLR. TYP. 10 2800.Q 10 2800.B 10 2800.B 59x60" CLR. 59x60" CLR. 10 2800.C 10 2800.F 10 2800.C 10 2800.F DOOR SWING ALLOWED TO ENCROACH ON CLEAR FLOOR SPACE PER 11B-603.2.3 1 22 0000.Q 10 2800.G 22 0000.R CLR 48" CLR 48" 22 0000.R22 0000.Q 10 2800.G 1 MEN 118 WOMEN 119 02 4116.A 02 4116.U 02 4116.CM 02 4116.CM 02 4116.A 02 4116.B 02 4116.CC 02 4116.U 02 4116.A02 4116.A 02 4116.CC 02 4116.A 02 4116.A 02 4116.B 02 4116.A 02 4116.B 02 4116.B 02 4116.U TYP. 02 4116.CM 02 4116.U 02 4116.A 02 4116.A 02 4116.A TYP. 02 4116.CM TYP. 02 4116.CC TYP. 02 4116.CC 02 4116.H 02 4116.E 02 4116.CB 02 4116.A TYP. 02 4116.B DEMO EXISTING PARTITION OR WALL FINISH DEMO - INTERIOR - TILE NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS A-501 & A-502 FOR ADDTIONAL INFORMATION. C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated EN L A R G E D F L O O R P L A N S A-401 JH JR 6/20/24 JR KEYNOTES 02 4116.A EXISTING PLUMBING FIXTURE TO BE REMOVED 02 4116.B EXISTING TOILET PARTITION TO BE REMOVED 02 4116.CB EXISTING INTERIOR WALL TO BE REMOVED. PROTECT IN PLACE EXISTING ADJACENT WALL. PATCH WALL GAP AFTER DEMOLITION OF EXISITNG WALL. 02 4116.CC EXISTING WALL TILE TO BE REMOVED. PREPARE WALL SURFACE FOR NEW TILE FINISH TYP. OF ALL RESTROOM WALLS. 02 4116.CM EXISTING GRAB BAR TO BE REMOVED 02 4116.E EXISTING DOOR AND FRAME TO BE REMOVED 02 4116.H EXISTING DOOR TO BE REMOVED. FLIP DOOR SWING DIRECTION AND REINSTALL. 02 4116.U EXISTING TILE FLOOR TO BE REMOVED. PREPARE (E) SLAB FOR NEW TILE FINISHES 10 2113.A TOILET COMPARTMENT 10 2113.B URINAL SCREEN 10 2113.C SELF CLOSING DOOR AT ACCESSIBLE TOILET STALL 10 2800.B SURFACE MOUNTED TOILET PAPER DISPENSER 10 2800.C SOAP DISPENSER 10 2800.F MIRROR 10 2800.G SEMI-RECESSED PAPER TOWEL DISPENSER 10 2800.Q GRAB BAR. 22 0000.Q SINK OR LAVATORY.REFER TO PLUMBING. 22 0000.R TOILET. REFER TO PLUMBING. 22 0000.T URINAL. REFER TO PLUMBING. 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. FLOOR PLAN GENERAL NOTES 2.REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION IF PROVIDED. 3. REFER TO MECHANICAL PLANS, DRAWINGS OR REPORTS FOR FURTHER INFORMATION. 4. REFER TO PLUMBING PLANS OR DRAWINGS FOR FURTHER INFORMATION IF PROVIDED. 5. NOT USED 6. DIMENSIONS ARE TO FACE OF EXISTING FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 7. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES. 8. PROVIDE FIREBLOCKING FOR WALL CAVITIES THAT EXCEED 2022 CBC HEIGHT LIMITATIONS 9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS 10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING 11. SEE CODE ANALYSIS FOR LOCATIONS OF FIRE PARTITIONS AND FIRE BARRIERS 12. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED 13. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS, PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING SCALE: 3/8" = 1'-0"A-102 A-401 2ND FLOOR RESTROOM - PROPOSED 3 FLOOR MATERIALS LEGEND SCALE: 3/8" = 1'-0"A-101 A-401 FIRST FLOOR RESTROOM - PROPOSED 4 SCALE: 3/8" = 1'-0"AD-101 A-401 FIRST FLOOR RESTROOM - DEMO 1 SCALE: 3/8" = 1'-0"AD-102 A-401 SECOND FLOOR RESTROOM - DEMO 2 1 9/13/24 09 3000.A 1' - 0" 3' - 6" 0' - 6" 1' - 0" 3' - 6" 3' - 6" 1' - 0" 1' - 0" 3' - 6" 1' - 0" 3' - 6" 1' - 0" 3' - 6" 1 1' - 0" 3' - 6" 3' - 6" 1' - 0" 1' - 0" 3' - 6" 1' - 0" 3' - 6" 0' - 6" 1' - 0" 3' - 6" 3' - 6" 1' - 0" 1' - 0" 3' - 6" 0' - 6" LVT-1 MATERIAL TAG REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS A-501 & A-502 FOR ADDTIONAL INFORMATION. ###DW H ARCHITECTURAL WOODWORK STANDARD CABINET DESIGN SERIES NUMBER OPT. DESIGN MOD DESCRIPTION D = DEPTH W = WIDTH H = HEIGHT C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 1/4" = 1'-0" I N T E R I O R E L E V A T I O N S A-411 JH JR 6/20/24 JR 1/4" = 1'-0"118 - MENS RESTROOM - FIRST FLOOR 1N 1E 1S 1W 2E 1/4" = 1'-0"119 - WOMENS RESTROOM - FIRST FLOOR 2N 2S 2W 1/4" = 1'-0"129 - MENS RESTROOM - SECOND FLOOR 3N 3E 3S 3W 1/4" = 1'-0"222 - WOMENS RESTROOM - SECOND FLOOR 4N 4E 4S 4W 09 3000.A CERAMIC TILE, WALL APPLICATION. KEYNOTES 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION ON ELECTRICAL EQUIPMENT. 3. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION. 4. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND FIXTURES OCCUR. 5. ALL DIMENSIONS SHOWN IN A ROOM TO BE CONSIDERED TYPICAL FOR EACH ELEVATION OF THE ROOM, UNLESS NOTED OTHERWISE. 6. VERIFY MOUNTING HEIGHTS OF ACCESSORIES AND PLUMBING FIXTURES MEET ACCESSIBILITY REQUIREMENTS WHERE APPLICABLE. 7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY. INT. ELEVS. GENERAL NOTES LEGEND1 9/13/24 10 A-902 S-4 126 10' - 0" TYP. 06 1000.Q 27 0000.B 27 0000.A LVT-1 MATERIAL TAG REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS A-501 & A-502 FOR ADDTIONAL INFORMATION. ###DW H ARCHITECTURAL WOODWORK STANDARD CABINET DESIGN SERIES NUMBER OPT. DESIGN MOD DESCRIPTION D = DEPTH W = WIDTH H = HEIGHT 06 1000.Q S-1 S-1 S-1 S-1 S-1 7' - 0" S-2 S-2 122A 122B 27 0000.B 27 0000.A 27 0000.A 02 4013.A 27 0000.B 02 4013.BK 08 8000.D 08 4313.A 11 5213.B 02 4013.A 08 8000.D 122B S-2 122A S-2 S-1S-1 S-1 S-1 S-1 114 08 4313.A 08 8000.D 02 4013.A 22 0000.O A-902 12 OPP 5' - 0" T-1 W/ TB-1 COVE BASE, INSIDE CORNER TO INSIDE CORNER AT DRINKING FOUNTAIN ALCOVE C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 1/4" = 1'-0" I N T E R I O R E L E V A T I O N S A-412 JH JR 6/20/24 JR1/4" = 1'-0"102 - OPEN OFFICE - PROPOSED 4 1. REFER TO GENERAL NOTES SHEET G-002 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION ON ELECTRICAL EQUIPMENT. 3. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION. 4. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND FIXTURES OCCUR. 5. ALL DIMENSIONS SHOWN IN A ROOM TO BE CONSIDERED TYPICAL FOR EACH ELEVATION OF THE ROOM, UNLESS NOTED OTHERWISE. 6. VERIFY MOUNTING HEIGHTS OF ACCESSORIES AND PLUMBING FIXTURES MEET ACCESSIBILITY REQUIREMENTS WHERE APPLICABLE. 7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY. 8. REFER TO FINISH SCHEDULE ON A-501 FOR WALL FINISH MATERIALS AND COLOR SELECTIONS. 9. TILE SHOULD STOP AT TOP OF DOOR JAMB. INT. ELEVS. GENERAL NOTES 02 4013.A EXISTING STOREFRONT TO REMAIN. PROTECT IN PLACE 02 4013.BK EXISTING PRIVACY FILM TO REMAIN. 06 1000.Q PROVIDE BLOCKING FOR FUTURE OWNER PROVIDED WALL-MOUNTED TV BRACKET 08 4313.A ALUMINUM STOREFRONT SYSTEM - REFER TO SCHEDULES. 08 8000.D FROSTED GLASS PRIVACY SCREEN 11 5213.B POWERED RETRACTABLE PROJECTION SCREEN, BY OWNER, COORDINATE POCKET INSTALLATION WITH CEILING 22 0000.O HI LOW DRINKING FOUNTAIN, REFER TO PLUMBING. 27 0000.A CABLE/DATA/POWER CONNECTION, RE ELEC 27 0000.B WALL MOUNTED TV, BY OWNER KEYNOTES 1/4" = 1'-0"102 - MEETING AREA 3 LEGEND 1/4" = 1'-0"122 - BRIEFING ROOM 1 2 5 1 1 9/13/24 V.I.F. 2' - 10" MODIFY CABINET TO PROVIDE ACCESSIBLE KITCHEN SINK, SEE DETAIL 9 A-903 V. I . F . 2' - 1 0 " 2' - 6" 2' - 0" 2' - 10" 24 33 24211 24 30 13301 48 30 13302 24 30 13301 48 33 24155 12 3600.D 42 33 42197 06 4100.O 06 4100.J 9 A-903 2' - 10" 2' - 0" 2' - 6" 48 33 24222 48 30 1330224 30 13301 42 33 42197 06 4100.O 06 4100.J 12 3600.D 11 3100.D LVT-1 MATERIAL TAG REFER TO MATERIAL SCHEDULE FOR MORE INFORMATION NOTE:REFER TO INTERIOR FINISH SCHEDULES ON SHEETS A-501 & A-502 FOR ADDTIONAL INFORMATION. ###DW H ARCHITECTURAL WOODWORK STANDARD CABINET DESIGN SERIES NUMBER OPT. DESIGN MOD DESCRIPTION D = DEPTH W = WIDTH H = HEIGHT C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated I N T E R I O R E L E V A T I O N S A-413 JH JR 6/20/24 JR 2 3/8" = 1'-0"BREAK RM 121 1 3/8" = 1'-0"BREAK RM 215 3 4 1. REFER TO GENERAL NOTES SHEET G-002 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION ON ELECTRICAL EQUIPMENT. 3. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION. 4. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND FIXTURES OCCUR. 5. ALL DIMENSIONS SHOWN IN A ROOM TO BE CONSIDERED TYPICAL FOR EACH ELEVATION OF THE ROOM, UNLESS NOTED OTHERWISE. 6. VERIFY MOUNTING HEIGHTS OF ACCESSORIES AND PLUMBING FIXTURES MEET ACCESSIBILITY REQUIREMENTS WHERE APPLICABLE. 7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY. 8. REFER TO FINISH SCHEDULE ON A-501 FOR WALL FINISH MATERIALS AND COLOR SELECTIONS. 9. TILE SHOULD STOP AT TOP OF DOOR JAMB. INT. ELEVS. GENERAL NOTES KEYNOTES LEGEND 06 4100.J BASE CABINETS W/ DRAWERS, DOORS & ADJUSTABLE SHELVING 06 4100.O UPPER CABINET W/ DOORS & ADJUSTABLE SHELVING. 11 3100.D REFRIGERATOR W/ ICE MAKER; OWNER FURNISHED AND INSTALLED. COORDINATE INSTALLATION WITH OWNER. 12 3600.D PLASTIC LAMINATE COUNTERTOP & BACKSPLASH 1 9/13/24 UP PF EXISTING FLOORING TO REMAIN FINISH LEGEND NEW PORCELAIN TILE FLOOR NEW LVT FLOOR NEW CARPET TILE FLOOR NEW WALK OFF MAT CARPET TILE STAINLESS STEEL CORNER GUARD FLOORING INSTALL DIRECTION SHARED OFFICE BUREAU SERGEANT STORAGE STAIR 251 SF LOBBY ELEV. OFFICE MEETING BRIEFING ROOM HALL HALL 121 SF STAIR MEN WOMEN 99 SF ELECTRICAL HALL JAN. DRONE/EQUIP. STORAGE DETECTIVE EQUIPMENT INCIDENT COM.BREAK ROOM STORAGE CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 LVT-1 LVT-1 LVT-1 LVT-1 LVT-1 LVT-1 WOM-1 WOM-1 RBR-1 RBR-1 CPT-1 P-3 T-1 T-1 T-2 T-2 P-2 P-2 P- 2 TB-1 P-3 P-3 P-3 TB-1 OPEN OFFICE P-2 P-2 B-1 B-1 (E) (E) (E) A G H B B A B A B B B B B RS-1 RS-1 RS-1 RS-1 RS-1 RS-1 RS-1 RS-1 E D E D 1 B B B B B A A B B A A K K G T-1 TACTILE EXIT SIGN READING "EXIT". WHERE MOUNTED ON GLASS, SIZE EXIT SIGN TO MATCH EXTERIOR GLASS MOUNTED ROOM IDENTIFICAITON SIGNAGE. ALIGN EXIT SIGN WITH ROOM SINGAGE WHEN MOUNTING.: ROOM IDENTIFICATION SIGN. WHERE MOUNTED ON GLASS PROVIDE SIZE MATCHED BLANK SIGNAGE PLATE ON BACK SIDE OF GLASS IF NO OTHER SINGAGE IS PROVIDED. CONTENT TBD BY OWNER: A B OCCUPANT LOAD SIGN THAT STATES "MAXIMUM OCCUPANCY 54 PERSONS" H GEOMETRIC SYMBOL MOUNTED ON DOOR.D E ROOM IDENTIFICATION WITH PICTOGRAM AND INTERNATIONAL SYMBOL OF ACCESSIBILITY. INTERNATIONAL SYMBOL OF ACCESS FOR HEARING IMPAIRED, INCLUDE WORDING THAT STATES, "ASSISTIVE LISTENING SYSTEM AVAILABLE." G SIGN TO READ "EXTERIOR AREA FOR ASSISTED RESCUE". SIGNAGE TO COMPLY WITH CBC 1009.9. J SIGN TO READ "PLEASE BE AWARE, VIDEO MONITORING IN PROGRESS"K 1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 1/8" = 1'-0" FI R S T F L O O R F I N I S H P L A N A-501 JH JR 6/20/24 JR INTERIOR FINISH SCHEDULE SCALE: 1/8" = 1'-0"A-501 01-FIRST FLOOR FINISH PLAN1 A-1 & A-2 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY (CBC 2022 TABLE 803.13) CLASSIFICATIONS CLASS A: • FLAME SPREAD INDEX = 0-25 • SMOKE DEVELOPED INDEX = 0-450 CLASS B: • FLAME SPREAD INDEX = 26-75 • SMOKE DEVELOPED INDEX = 0-450 CLASS C: • FLAME SPREAD INDEX = 76-200 • SMOKE DEVELOPED INDEX = 0-450 A-3,A-4,A-5 B,E,M,R-1 R-2 R-2.1 R-2.2 R-3, R-3.1 S GROUP INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS ROOMS AND ENCLOSED SPACES B B B C B C C C B B C C C C C C C C C C C C C C PER 2022 CBC 803.13 INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE 803.13 FOR THE GROUP AND LOCATION DESIGNATED. REFER TO 2022 CBC SEC. 803 FOR ADDITIONAL INFORMATION. DEGREE OF FIRE PROTECTION: SPRINKLERED FINISH REQUIREMENTS 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 3. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION. 4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES AND INTERIOR FINISH DETAILS. 5. ALL HARD SURFACE FLOORING SHALL BE SLIP RESISTANT AND MEET THE ANSI A326.3 STANDARD FOR MEASURING THE DYNAMIC COEFFICIENT OF FRICTION (DCOF). 6. ALL FLOORING MATERIALS SHALL COMPLY WITH 2022 CBC SEC. 804.1. 7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY. 8. PROVIDE ROLLER SHADES AT ALL EXTERIOR WINDOWS AND STOREFRONT EXCEPT AT DOORS. SEE SPECS FINISH PLAN GENERAL NOTES CSI Spec Section TAG DESCRIPTION LOCATION MANUFACTURER PRODUCT SPEC SIZE FINISH / COLOR NOTES (E) EXISTING FINISH TO REMAIN SEE PLANS 06 4000- ARCHITECTURAL WOODWORK 06 4000- ARCHITECTURAL WOODWORK PL-2 PLASTIC LAMINATE - CABINETS BREAK ROOM NEVAMAR NAVY MATRIX (MR3005T) 09 3000 - TILING 09 3000 - TILING T-1 CERAMIC FLOOR & WALL TILE RESTROOMS DALTILE DIGNITARY 12" X 24" SUPERIOR TAUPE 09 3000 - TILING T-2 ACCENT CERAMIC WALL TILE RESTROOMS DALTILE REVALIA REMIX RADIANT BLUE FAN 12" ACCENT STRIP STARTING AT 48" 09 3000 - TILING TB-1 CERAMIC TILE COVE BASE RESTROOMS DALTILE DIGNITARY 6" X 12" SUPERIOR TAUPE 09 6500 - RESILIENT FLOORING 09 6500 - RESILIENT FLOORING B-1 GENERAL BASE GENERAL U.O.N. ROPPE PINNACLE 4" H (ROLL) BLACK (100) 09 6500 - RESILIENT FLOORING LVT-1 LUXURY VINYL TILE BREAK ROOM, EQUIP., STORAGE MILLIKEN METRO PARK | PIKE 7" x 48" ANTLER ASHLAR INSTALLATION 09 6500 - RESILIENT FLOORING RBR-1 RUBBER STAIR TREADS STAIRS ROPPE RAISED CIRCULAR VANTAGE DESIGN WITH RISER #96 CHARCOAL (123) 09 6813 - TILE CARPETING 09 6813 - TILE CARPETING CPT-1 CARPET TILE GENERAL CARPET TILE U.O.N. SHAW CONTRACT DIFFUSE + DISPERSE | DIFFUSE ECOWORX 24" x 24" MAGNETIC FIELD QUARTER TURN INSTALLATION 09 6813 - TILE CARPETING WOM-1 CARPET TILE EXITS SHAW CONTRACT ALL ACCESS | PACE TILE 24" x 24" STEP MONOLITHIC INSTALLATION 09 9123 - INTERIOR PAINTING 09 9123 - INTERIOR PAINTING P-1 GENERAL DINING PAINT GENERAL U.O.N. SHERMIN WILLIAMS PASSIVE (SW 7064) EGGSHELL FINISH 09 9123 - INTERIOR PAINTING P-2 ACCENT PAINT PRIVATE OFFICES, PAINTED DOORS AND HM DOOR TRIM SHERMIN WILLIAMS STAMPED CONCRETE (SW 7655) EGGSHELL FINISH 09 9123 - INTERIOR PAINTING P-3 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS DISTANCE (SW 6243) EGGSHELL FINISH 09 9123 - INTERIOR PAINTING P-4 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS IN THE NAVY (SW 9178) EGGSHELL FINISH 10 2113.19 - PLASTIC TOILET COMPARTMENTS 10 2113.19 - PLASTIC TOILET COMPARTMENTS TP-1 CARPET TILE SECOND LEVEL RESTROOMS ASI SOLID PLASTIC (HDPE) PARTITIONS CHARCOAL (9237) FLOOR ANCHORED / OVERHEAD BRACED 12 2400 - WINDOW SHADES 12 2400 - WINDOW SHADES RS-1 ROLLER SHADE SEE PLANS MECHO SHADES MANUAL ROLLER SHADES WITH ECOVEIL SCREENS (1% OPEN) SILVER BIRCH ADD ALT TO REPLACE ALL WINDOW SHADES PER PLAN 12 3600 - COUNTERTOPS 12 3600 - COUNTERTOPS PL-1 PLASTIC LAMINATE - COUNTER BREAK ROOM FORMICA SEA SEALT (9529-43) SIGNAGE LEGEND 9/13/24 UP UP PF EXISTING FLOORING TO REMAIN FINISH LEGEND NEW PORCELAIN TILE FLOOR NEW LVT FLOOR NEW CARPET TILE FLOOR NEW WALK OFF MAT CARPET TILE STAINLESS STEEL CORNER GUARD FLOORING INSTALL DIRECTION BREAK ROOM SERVER WOMENS MENSMEETING ROOM ELEVATOR 131 COPY ROOM ELEV MECH DEPT. CHIEF CRIME ANALYST TRAIN/HIRING MANAGER EQUIP. ADMIN DEPT. CHIEF INT AFFAIRS LIEUT. BREAK ROOM BOS. MANAGER PUBLIC AFFAIRS MANAGER HALL 149 JAN. CONF. STAIRS 152 STAIRS 144 JAN. 216 CHIEF RBR-1 RBR-1 CPT-1 CPT-1 CPT-1 T-1 T-2 P-3 TB-1 T-1 T-1 T-2 TB-1 T-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1 CPT-1CPT-1 LVT-1 LVT-1 LVT-1 P- 2 P- 2 P- 2 P- 2 P- 3 P-3 CPT-1 HALL 132 (E) CPT-1 CPT-1 (E) (E) (E) CPT-1 P- 2 P- 2 P-3 P- 2 P-2 P-2 P-4 P-4 P- 3 G B B B B B B B B B A B TP-1 TP-1 RS-1 RS-1 RS-1 RS-1RS-1RS-1RS-1 RS - 1 PL-1 PL-2 D E D E B B B B B B G TACTILE EXIT SIGN READING "EXIT". WHERE MOUNTED ON GLASS, SIZE EXIT SIGN TO MATCH EXTERIOR GLASS MOUNTED ROOM IDENTIFICAITON SIGNAGE. ALIGN EXIT SIGN WITH ROOM SINGAGE WHEN MOUNTING.: ROOM IDENTIFICATION SIGN. WHERE MOUNTED ON GLASS PROVIDE SIZE MATCHED BLANK SIGNAGE PLATE ON BACK SIDE OF GLASS IF NO OTHER SINGAGE IS PROVIDED. CONTENT TBD BY OWNER: A B OCCUPANT LOAD SIGN THAT STATES "MAXIMUM OCCUPANCY 54 PERSONS" H GEOMETRIC SYMBOL MOUNTED ON DOOR.D E ROOM IDENTIFICATION WITH PICTOGRAM AND INTERNATIONAL SYMBOL OF ACCESSIBILITY. INTERNATIONAL SYMBOL OF ACCESS FOR HEARING IMPAIRED, INCLUDE WORDING THAT STATES, "ASSISTIVE LISTENING SYSTEM AVAILABLE." G SIGN TO READ "EXTERIOR AREA FOR ASSISTED RESCUE". SIGNAGE TO COMPLY WITH CBC 1009.9. J SIGN TO READ "PLEASE BE AWARE, VIDEO MONITORING IN PROGRESS"K 1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 1/8" = 1'-0" SE C O N D F L O O R F I N I S H P L A N A-502 JH JR 6/20/24 JR ROOM FINISH SCHEDULE A-1 & A-2 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY (CBC 2022 TABLE 803.13) CLASSIFICATIONS CLASS A: • FLAME SPREAD INDEX = 0-25 • SMOKE DEVELOPED INDEX = 0-450 CLASS B: • FLAME SPREAD INDEX = 26-75 • SMOKE DEVELOPED INDEX = 0-450 CLASS C: • FLAME SPREAD INDEX = 76-200 • SMOKE DEVELOPED INDEX = 0-450 A-3,A-4,A-5 B,E,M,R-1 R-2 R-2.1 R-2.2 R-3, R-3.1 S GROUP INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS ROOMS AND ENCLOSED SPACES B B B C B C C C B B C C C C C C C C C C C C C C PER 2022 CBC 803.13 INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE 803.13 FOR THE GROUP AND LOCATION DESIGNATED. REFER TO 2022 CBC SEC. 803 FOR ADDITIONAL INFORMATION. DEGREE OF FIRE PROTECTION: SPRINKLERED FINISH REQUIREMENTS 1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS. 2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 3. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION. 4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES AND INTERIOR FINISH DETAILS. 5. ALL HARD SURFACE FLOORING SHALL BE SLIP RESISTANT AND MEET THE ANSI A326.3 STANDARD FOR MEASURING THE DYNAMIC COEFFICIENT OF FRICTION (DCOF). 6. ALL FLOORING MATERIALS SHALL COMPLY WITH 2022 CBC SEC. 804.1. 7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2022 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY. 8. PROVIDE ROLLER SHADES AT ALL EXTERIOR WINDOWS AND STOREFRONT EXCEPT AT DOORS. SEE SPECS FINISH PLAN GENERAL NOTES SCALE: 1/8" = 1'-0"A-502 SECOND FLOOR FINISH PLAN1 CSI Spec Section TAG DESCRIPTION LOCATION MANUFACTURER PRODUCT SPEC SIZE FINISH / COLOR NOTES (E) EXISTING FINISH TO REMAIN SEE PLANS 06 4000- ARCHITECTURAL WOODWORK 06 4000- ARCHITECTURAL WOODWORK PL-2 PLASTIC LAMINATE - CABINETS BREAK ROOM NEVAMAR NAVY MATRIX (MR3005T) 09 3000 - TILING 09 3000 - TILING T-1 CERAMIC FLOOR & WALL TILE RESTROOMS DALTILE DIGNITARY 12" X 24" SUPERIOR TAUPE 09 3000 - TILING T-2 ACCENT CERAMIC WALL TILE RESTROOMS DALTILE REVALIA REMIX RADIANT BLUE FAN 12" ACCENT STRIP STARTING AT 48" 09 3000 - TILING TB-1 CERAMIC TILE COVE BASE RESTROOMS DALTILE DIGNITARY 6" X 12" SUPERIOR TAUPE 09 6500 - RESILIENT FLOORING 09 6500 - RESILIENT FLOORING B-1 GENERAL BASE GENERAL U.O.N. ROPPE PINNACLE 4" H (ROLL) BLACK (100) 09 6500 - RESILIENT FLOORING LVT-1 LUXURY VINYL TILE BREAK ROOM, EQUIP., STORAGE MILLIKEN METRO PARK | PIKE 7" x 48" ANTLER ASHLAR INSTALLATION 09 6500 - RESILIENT FLOORING RBR-1 RUBBER STAIR TREADS STAIRS ROPPE RAISED CIRCULAR VANTAGE DESIGN WITH RISER #96 CHARCOAL (123) 09 6813 - TILE CARPETING 09 6813 - TILE CARPETING CPT-1 CARPET TILE GENERAL CARPET TILE U.O.N. SHAW CONTRACT DIFFUSE + DISPERSE | DIFFUSE ECOWORX 24" x 24" MAGNETIC FIELD QUARTER TURN INSTALLATION 09 6813 - TILE CARPETING WOM-1 CARPET TILE EXITS SHAW CONTRACT ALL ACCESS | PACE TILE 24" x 24" STEP MONOLITHIC INSTALLATION 09 9123 - INTERIOR PAINTING 09 9123 - INTERIOR PAINTING P-1 GENERAL DINING PAINT GENERAL U.O.N. SHERMIN WILLIAMS PASSIVE (SW 7064) EGGSHELL FINISH 09 9123 - INTERIOR PAINTING P-2 ACCENT PAINT PRIVATE OFFICES, PAINTED DOORS AND HM DOOR TRIM SHERMIN WILLIAMS STAMPED CONCRETE (SW 7655) EGGSHELL FINISH 09 9123 - INTERIOR PAINTING P-3 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS DISTANCE (SW 6243) EGGSHELL FINISH 09 9123 - INTERIOR PAINTING P-4 ACCENT PAINT SEE PLANS SHERMIN WILLIAMS IN THE NAVY (SW 9178) EGGSHELL FINISH 10 2113.19 - PLASTIC TOILET COMPARTMENTS 10 2113.19 - PLASTIC TOILET COMPARTMENTS TP-1 CARPET TILE SECOND LEVEL RESTROOMS ASI SOLID PLASTIC (HDPE) PARTITIONS CHARCOAL (9237) FLOOR ANCHORED / OVERHEAD BRACED 12 2400 - WINDOW SHADES 12 2400 - WINDOW SHADES RS-1 ROLLER SHADE SEE PLANS MECHO SHADES MANUAL ROLLER SHADES WITH ECOVEIL SCREENS (1% OPEN) SILVER BIRCH ADD ALT TO REPLACE ALL WINDOW SHADES PER PLAN 12 3600 - COUNTERTOPS 12 3600 - COUNTERTOPS PL-1 PLASTIC LAMINATE - COUNTER BREAK ROOM FORMICA SEA SEALT (9529-43) SIGNAGE LEGEND 1 9/13/24 PF BUREAU SERGEANT 107 MEETING 125 OFFICE 124 DRONE/EQUIP. STORAGE 105 DETECTIVE EQUIPMENT 106 ELECTRICAL 120 WOMEN 119 MEN 118 HALL 114 JAN. 117 HALL 115 STORAGE 111 STAIR 122 STAIR 123 BRIEFING ROOM 122 HALL 139 LOBBY 100 ELEV. 127 SHARED OFFICE 126 3' - 10 7/16" 7' - 0 " 4' - 0 " 2' - 9" 2' - 6" SEE SUPPORTING DOCUMENTS FOR FURNITURE SCHEDULE 2' - 8 3/4" BREAK ROOM 121 INCIDENT COM. 123 SE-04 CG-06 SE-05 CG-05 CG-03 SE-06 CG-08 SE-01 CG-08 SE-01 CG-09 SE-01 ST-01 ST-05 CG-13 SE-01 ST-01 ST-02 ST-02 CG-11 SE-01 ST-01 SE-02 SE-02 ST-07ST-07 7' - 9" CG-20 7' - 5 57/128" SE-03 SE-03 CG-23 CG-10 CG-27 E-5 E-4 E-3 E-2 E-1 ST-01 TYP. TYP. ST-01 ST-01 OPEN OFFICE 102 ST-04 CG-14 TYP. TYP. ST-01 TYP. CG-09 ST-01 1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 3/16" = 1'-0" FI R S T F L O O R F U R N I T U R E P L A N A-503 JH JR 6/20/24 JR SCALE: 3/16" = 1'-0"A-503 FIRST FLOOR FURNITURE PLAN1 9/13/24 UP UP BREAK ROOM 215 SERVER 216 WOMENS 222 MENS 129 MEETING ROOM 202 ELEVATOR 131 COPY ROOM 210 ELEV MECH 112 DEPT. CHIEF 211 CRIME ANALYST 209 TRAIN/HIRING MANAGER 208 EQUIP. 220 ADMIN 214A DEPT. CHIEF 213 INT AFFAIRS LIEUT. 224 BREAK ROOM 207BOS. MANAGER 206 PUBLIC AFFAIRS MANAGER 205 HALL 149 JAN. 223 CONF. 202 STAIRS 152 STAIRS 144 JAN. 216 CHIEF 214C REF. ST O R A G E ST-03 CG-15 SE-01 ST-08 SE-03 SE-08 CG-17 CG-18 SE-03 CG-16 ST-07 ST-01 CG-13 SE-01 SE-03 ST-06 CG-07 SE-04 SE-09 ST-04 SE-05 CG-05 ST-02 ST-01 CG-12 SE-01 SE-03 ST-02 ST-01 CG-12 SE-01 SE-03 SE-03 CG-04 SE-01 CG-13 ST-01 SE-01 ST-01 CG-13 ST-02 ST-01 CG-11 SE-01 SE-03 7' - 6 1/2"2' - 10 7/16"7' - 4 1/2"2' - 0"10' - 10" 5' - 5" 5' - 1 1 " 6' - 2 " 0" 2 ' - 0 " 8 ' - 5 " CG-29 12' - 2" 3' - 10" CG-03 SE-06ST-05 SE-01 ST-01 CG-13 ST-02 CG-21 CG-30 ST-06 CG-30 CG-22 CG-25 CG-26 SE-03 SE-03 SE-03 CG-19CG-14 CG-28 ST-02 ST-02 E-6 CG-14 ST-04 ST-02 ST-01 CG-12 SE-01 SE-03 CG-24 SEE SUPPORTING DOCUMENTS FOR FURNITURE SCHEDULE 1 C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 3/16" = 1'-0" SE C O N D F L O O R F U R N I T U R E P L A N A-504 JH JR 6/20/24 JR SCALE: 3/16" = 1'-0"A-504 SECOND FLOOR FURNITURE PLAN1 9/13/24 0' - 2"W 0' - 2" 0' - 2" H H W TYPE 1A F1 DOOR TYPES FRAME TYPES FF H W TYPE 1D FULL LITE OBSCURED W/ WINDOW PRIVACY FILMH W TYPE 1B 6" 8" 3' - 7 " 2 ' - 9 " 8 " 8" 1' - 0 " 1 V.I.F. 4' - 0" V.I.F. 7' - 2 3/4" V.I.F. 3' - 3" 0' - 2"0' - 2" 0' - 2" 0' - 2" 2' - 2 3/4" 4' - 8" ALUMINUM STOREFRONT 2" X 4-1/2" FIXED S-1 5 A-901 4 A-901 6 A-901 V.I.F. 11' - 2 3/4" FLOAT GLASS, TEMPERED OBSCURED GLASS, TEMPERED INSTALL WINDOW PRIVACY FILM GLAZING LEGEND TYPICAL DETAILS TYPICAL JAMB AT ADJACENT STOREFRONT ALUMINUM STOREFRONT 2" X 4-1/2" DOOR WITH TRANSOM S-2 V.I.F. 3' - 4" 0' - 2"0' - 2" V.I.F. 11' - 2 3/4" 7' - 0" 0' - 2" 3' - 10 3/4" 0' - 2" FULL LITE OBSCURED W/ WINDOW PRIVACY FILM 5 A-901 1 A-901 1. CL 2. HM 3. MP 4. STL 5. WD 6. T CHAIN LINK HOLLOW METAL METAL PICKET STEEL WOOD SAFETY GLAZING FULL LITE OBSCURED W/ WINDOW PRIVACY FILM ALUMINUM STOREFRONT 2" X 4-1/2" S-3 0' - 2"4' - 8"0' - 2"6' - 0"0' - 2"4' - 8"0' - 2" 16' - 0" 11' - 2 3/4" 0' - 2" 2' - 10 3/4" 0' - 2" 5' - 6" 0' - 2" 2' - 4" 8' - 0" 3 A-901 1 A-901 6 A-901 1 3' - 0" 0' - 2" 2' - 10" 100A ALUMINUM STOREFRONT 2" X 4-1/2" 6 A-901 1 A-901 3 A-901 S-4 126 7' - 2" 0' - 2" 6' - 10" 0' - 2" 8' - 5" 2"2' - 4 1/2" 2" 2' - 4 1/2" 2" 3' - 0"2" C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DO O R A N D W I N D O W S C H E D U L E S A-601 JH JR 6/20/24 JR DOOR TYPES LEGEND DOOR SCHEDULE 1. REFER TO GENERAL NOTES ON SHEET G-101 FOR ADDITIONAL REQUIREMENTS 2. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. 3. CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES WITH DOOR MANUFACTURER SPECIFICATIONS PRIOR TO FABRICATION OF ROUGH OPENINGS. 4. CONTRACTOR TO VERIFY ACTUAL DOOR SIZES TO FIT FINISH OPENING PRIOR TO FABRICATION OF DOOR AND FINISH OPENING. 5. REFER TO DOOR TYPES LEGEND FOR GLAZING. 6. REFER TO T24 REPORT FOR GLAZING ENERGY REQUIREMENTS 7. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS 8. REFER TO FINISH SCHEDULE ON A-501 AND A-502 FOR DOOR AND FRAME PAINT COLORS. DOOR GENERAL NOTES 1. EGRESS DOOR. 2. EQUIPPED W/PANIC HARDWARE. . 3. INCLUDES SAFETY GLAZING. 4. FIRE-RATED DOOR ASSEMBLY. VISION PANELS OR LITES TO RECEIVE WIRE GLASS. 5. LOUVERED DOOR. 6. EXISTING DOOR TO CHANGE SWING DIRECTION FROM IN TO OUT, ADJUST AND REINSTALL HARDWARE AS NEEDED. 7. CLOSER BUT NO LATCH, PUSH PLATE PROVIDED. 8. PROVIDE PRIVACY LOCKSET TO MATCH EXISTING. DOOR REMARKS NO. SIZE DOOR FRAME HARDWARE GROUP DETAIL REMARKSWIDTH HEIGHT THICKNESS TYPE MAT'L TYPE MAT'L SILL JAMB HEAD 100A 3' - 0" 8' - 0" 1 3/4" 1D ALUM F1 ALUM 01 1/A-901 6/A-901 6/A-901 1,2,3 111B 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 02 2/A-901 2/A-901 3 114 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 03 2/A-901 2/A-901 1,2,3 122A 3' - 0" 7' - 0" 1 3/4" 1D ALUM F1 ALUM 04 1/A-901 6/A-901 6/A-901 1,2,3 122B 3' - 0" 7' - 0" 1 3/4" 1D ALUM F1 ALUM 05 1/A-901 6/A-901 6/A-901 2,3 126 3' - 0" 7' - 0" 1 3/4" 1A ALUM F1 ALUM 06 1/A-901 6/A-901 6/A-901 214 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 07 3 224 3' - 0" 7' - 0" 1 3/4" 1B WD F1 HM 03 2/A-901 2/A-901 1,2,3 E111A 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST 6,8 E222 3' - 0" 8' - 0" 1 3/4" EXIST EXIST EXIST EXIST 6,7 WINDOW AND STOREFRONT TYPES DOOR MATERIAL LEGEND 1. REFER TO GENERAL NOTES ON SHEET G-101 FOR ADDITIONAL REQUIREMENTS 2. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. 3. CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES WITH WINDOW MANUFACTURER SPECIFICATIONS PRIOR TO FABRICATION OF ROUGH OPENINGS. 4. CONTRACTOR TO VERIFY ACTUAL WINDOW SIZES TO FIT FINISH OPENING PRIOR TO FABRICATION OF WINDOW AND FINISH OPENING. 5. HEAD HEIGHT MEASURED FROM FF UNLESS NOTED OTHERWISE. 6. REFER TO ENERGY COMPLIANCE REPORTS FOR U-FACTOR, SHGC AND ADDITIONAL WINDOW REQUIREMENTS. 7. ALL EXTERIOR GLAZING IS DOUBLE PANE UNLESS OTHERWISE NOTED. 8. REFER TO STOREFRONT AND WINDOW TYPES LEGEND FOR GLAZING. 9. ALL GLAZING IS TO BE SAFTEY GLAZING (TEMPERED). 10. ALL OPERABLE WINDOWS ARE TO BE PROVIDED WITH LIMITERS RESTRICTING WINDOW PROJECTIONS TO 4". 11. ALL OPERABLE WINDOWS ARE TO BE PROVIDED WITH WINDOW SCREENS. WINDOW GENERAL NOTES 1 1 1 9/13/24 (E) CONCRETE SLAB ALUMINUM STOREFRONT FRAME BEYOND ALUMINUM STOREFRONT DOOR FRAME & DOOR HEAD/JAMB SIMILAR GYPSUM BOARD WALL FRAMING HOLLOW METAL DOOR SYSTEM DOOR PANEL 10 d. x 2.5" NAILS PER MANUF. FLOOR FINISH MAX. 1/2" (E) METAL STUD WALL FRAMING ALUMINUM STOREFRONT EQ EQ (E) GYP. BD. NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN. (E) VERIFY IN FIELD +4'-0" A.F.F. BACKER ROD AND SEALANT, TYP 5/8" CASING BEAD TRIM (E) CONCRETE SLAB 1/2" SHIM ALUMINUM STOREFRONT FRAME BEYOND BACKER ROD AND SEALANT, TYP ALUMINUM STOREFRONT 1/2" SHIM 5/8" GYP. BD. ALUMINUM STOREFRONT EQ.EQ. 3/4" PLY 3-5/8" LIGHT GUAGE METAL STUD. 362S162-33 5/8" "J" CASING BEAD TRIM BACKER ROD AND SEALANT, TYP ALUMINUM STOREFRONT (E) SOFFIT FRAMING EQ EQ GYP. BD. EXISTING SOFFIT FRAMING TO REMAIN (E) VERIFY IN FIELD BACKER ROD AND SEALANT, TYP NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN. (E) STEEL STUD FRAMING TO REMAIN C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 3" = 1'-0" DO O R & W I N D O W D E T A I L S A-901 JH JR 6/20/24 JR SCALE: 3" = 1'-0"A-601 A-901 INT. STOREFRONT DOOR1 SCALE: 3" = 1'-0"A-901 INT. DOOR -HEAD/JAMB2 SCALE: 3" = 1'-0"A-601 A-901 STOREFRONT SILL @(E) WALL4 SCALE: 3" = 1'-0"A-601 A-901 ALUM. STOREFRONT SILL @FLOOR3 SCALE: 3" = 1'-0"A-601 A-901 ALUM. STOREFRONT JAMB/HEAD6 SCALE: 3" = 1'-0"A-601 A-901 STOREFRONT HEAD @ (E) SOFFIT5 9/13/24 (E) STEEL STUD TO REMAIN (E) GYP BD TO REMAIN (N) 5/8" GYP BD (E) VERIFY IN FIELD 3-5/8" LIGHT GUAGE MTL STUD CORNER BEAD 3-5/8" LIGHT GUAGE MTL STUD SCHEDULED FINISH, TYP. HILTI X-U 72 PB S36 W/ FLAT WASHER @32" O.C. & 5" & 10" OF ENDS, 1" MIN EMBED (ICC-ES ESR 2268) (E) CONC. FLOOR BOTTOM CHANNEL NOTE: 1. WALL FRAMING TO ACCOMODATE 5LB/SF INT. LOAD. 2. LINE CAULK BETWEEN WALL AND RUNNER (TYP) METAL STUD WALL FRAMING. 362S162-33 ACOUSTICAL CEILING PANEL NOTE: WALL FRAMING TO ACCOMODATE 5LB/SF INT. LOAD. WALL SOUND INSULATION ABOVE CLNG. 0' - 6" LIGHT GUAGE METAL STUD (362S162-33) BRACE TO STRUCTURE ABOVE @48" O.C. STAGGERED TOP TRACK 362T162-33 NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN. SIMPSON A34 ATTACHED W/ SELF- TAPPING SCREWS TO SIDE OF BRACE AND TOP OF TRACK. ATTACH BRACE TO TRACK WITH #8 SELF-TAPPING SCREWS. ATTACH TRACK TO EXISTING ROOF DECK (E) FRAMING 2 #10 SCREWS @ 24" O.C. 2X4 20 GA SOFFIT FRAMING @ 16" O.C. - REFER TO RCP FOR SOFFIT TYPES 2X BRACING @ 4'-0" O.C. ATTACH TO STRUCTURAL FRAMING W/ "SIMPSON" DTC (SLOTTED LEG VERT J) @ EACH JOIST OR 24" O.C. @ BLOCKING SCHEDULED CEILING WALL PER PLAN 20 GA 2X4 MTL STUD OR 2X6 BLOCKING PER FRAMING CORNER BEAD SCHEDULED FINISH - TYP 2 - #10 SCREWS @24" O.C. REFER TO RCP REFER TO RCP 0' - 1" 0' - 6" A-902 7 A-902 8 A-902 2 (E) ACOUSTICAL CEILING TILE, REFER TO RCP NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN. (E) ACT +12'-2" A.F.F. (E) STEEL STUD TO REMAIN (E) CONC. SLAB ACOUSTICAL LAY-IN TILE CEILING. REFER TO RCP GYP. B.D CEILING. REFER TO RCP +10'-0" A.F.F. +9'-0" A.F.F. +8'-5" A.F.F. EXISTING BULK HEAD TO BE REMOVED (E) MTL. STUD KICKERS @48" O.C. BRACED TO STRUCTURE ABOVE. V.I.F. 5/8" GYP. BD. CEILING. REFER TO RCP GYP. BD. +8'-5" 3-5/8" LIGHT GUAGE MTL STUD. 362S162-33 CORNER BEAD+10'-0" 5/8" GYP. BD. LIGHT GUAGE METAL STUD (362S162-33) BRACE TO WALL (E) STEEL STUD TO REMAIN (E) GYP BD TO REMAIN 5/8" GYP BD. CEILING. REFER TO RCP 3-5/8" LIGHT GUAGE MTL STUD. 362S162-33 CORNER BEAD (E) BULKHEAD HT. +8'-5" VERIFY IN FIELD ACT +9'-0" A.F.F. NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN. ACOUSTICAL CEILING TILE, REFER TO RCP LIGHT GUAGE METAL STUD (362S162-33) BRACE TO WALL 3-5/8" LIGHT GUAGE METAL STUD. 362S162-33 NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN. LIGHT GUAGE METAL STUD (362S162-33) BRACE TO STRUCTURE ABOVE @48" O.C. STAGGERED ALUMINUM STOREFRONT BACKER ROD AND SEALANT, TYP (E) METAL STUD SOFFIT FRAMING TO REMAIN GYP. BD. WHERE OCCURS. FASTEN TO (E) SOFFIT FRAMING. REFER TO RCP NEW ACT WHERE OCCURS. REFER TO RCP 5/8" GYP. BD. CEILING SOFFIT REFER TO RCP REFER TO RCP REFER TO RCP REFER TO RCP C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DE T A I L S A-902 JH JR 6/20/24 JR SCALE: 3" = 1'-0"A-902 TYP. BULKHEAD3 SCALE: 3" = 1'-0"A-902 A-902 TYP. PARTITION TO FLOOR2 SCALE: 3" = 1'-0"A-902 PARTITION BRACING PARTIAL HT.1 SCALE: 1 1/2" = 1'-0"A-902 TYP. SOFFIT FRAMING6 SCALE: 3/4" = 1'-0"A-111 A-902 WALL SECTION -SHARED OFFICE10 SCALE: 3" = 1'-0"A-902 A-902 CEILING FRAMING 17 SCALE: 3" = 1'-0"A-902 A-902 CEILING FRAMING 28 SCALE: 1 1/2" = 1'-0"A-111 A-902 SOFFIT DETAIL12 9/13/24 1' - 0 " 8" ELEVATION WOOD STUDS, REF. TO STRUCTURAL 2X6 BLOCKING CONNECT EACH END OF BLOCKING TO STUD IN ANY MEHTOD DETAILED BELOW AT CONTRACTOR'S OPTION, U.O.N. OFFSET AT EACH STUD BAY TO AVOID FASTENER CONFLICT USE:#10 WOOD SCREW MIN. TO ATTACH ACCESSORIES TO BLOCKING, U.O.N. FOR: MIRRORS, FLAT SIGNS, TACKBOARDS, CHALKBOARDS, MARKER BOARDS, BULLETIN BOARDS, FRAMED ARTWORK. NOTES: 1. DO NOT CUT OR NOTCH STUDS TO INSTALL BLOCKING 2. VERIFY LENGTH, HEIGHT, QUANTITY, AND LOCATION FOR BLOCKING WITH ARCHITECTURAL DETAILS AND ACCESSORY MANUFACTURER 3. EXTEND BLOCKING TO FIRST STUD PAST END OF ACCESSORY 4. REFER TO STRUCTURAL DETAILS FOR MINIMUM LOAD LIMITS ON BLOCKING (AT 2X STUD ONLY) (3) 16d END NAILS 2x STUD 2x6 BLOCK (4) 8d TOE NAILS 1-TOP & BOTTOM 2-ON FACE FLUSH W/ STUD STUD, ANY THICKNESS 2x6 BLOCK STUD, ANY THICKNESS 2x6 BLOCK SIMPSON A21 TOP & BOTTOM (2-8d NAILS TO EACH MEMBER) METHOD A METHOD B METHOD C A A SECTION A-A PLAN 2X6 BLOCKING WOOD STUDS ELEVATION SECTION PLAN "SIMPSON" A35 AT EACH END OF BLOCKING. ALTERNATE TOP & BOTTOM, TYP. OFFSET BLOCKING AT EACH STUD BAY TO AVOID FASTENER CONFLICT WOOD STUDS, REF. TO STRUCTURAL 4X6 BLOCKING USE:#12 WOOD SCREW MIN. TO ATTACH ACCESSORIES TO BLOCKING, U.O.N. FOR: TOILET & BATH ACCESSORIES, DOOR STOPS, DOOR HOLDERS, CABINETS, DISPLAY CABINETS, TOILET PARTITIONS NOTES: 1. DO NOT CUT OR NOTCH STUDS TO INSTALL BLOCKING 2. VERIFY LENGTH, HEIGHT, QUANTITY, AND LOCATION FOR BLOCKING WITH ARCHITECTURAL DETAILS AND ACCESSORY MANUFACTURER 3. EXTEND BLOCKING TO FIRST STUD PAST END OF ACCESSORY 4. REFER TO STRUCTURAL DETAILS FOR MINIMUM LOAD LIMITS ON BLOCKING USE: # 14 WOOD SCREW MIN. OR 1/4" DIAMETER WOOD SCREW MIN. TO ATTACH ACCESSORIES TO BLOCKING, U.O.N. FOR:HANDRAILS, GRAB BARS, SHOWER SEATS, SHELF BRACKETS, COUNTERTOP BRACKETS, URINAL SCREENS, WATER HEATER STRAPS, SINK BRACKETS, ETC. A A A-A 2"x3"x3/16", 20" LONG METAL SUPPORT W/90 DEGREE LEG 20" LONG BOLTED TO COUNTER @ 30" O.C. MIRROR WALL FRAMING - REFER TO FLOOR PLAN 4" BACKSPLASH SOLID-SURFACE COUNTERTOP PER SPEC 1/2" PLYWOOD O/2x4 FRAMING SKIRT TO MATCH COUNTERTOP SINK PER PLUMBING METAL SUPPPORT BRACKET W/(2) 1/2" BOLTS TO 2x4 COUNTER TOP FRAMING 2x4 BLOCK SCREWED TO STUD BLOCK WASTE PIPING - SEE PLUMBING PLAN 20 GA PLATE W/ 4 #10 SCREWS WALL FINISH, REFER TO SCHEDULE CLEAR ZONE, SEE DETAIL T-1.3/xxxx WATER-RESISTANT GYPSUM BOARD WALL FRAMING - REFER TO FLOOR PLAN FOR WALL TYPES CABINET PROVIDE SLEEVE NUTS & SCREW FASTENERS BETWEEN EACH CABINET UNIT @ TOP & BOTTOM, FRONT & BACK BLOCKING AT CABINET TOP & BOTTOM GYPSUM BD WALL FINISH (O/PLYWOOD SHEATHING PER STRUCTURAL W.O.) #10 W.S. @ 12" O.C. MIN (3) PER CABINET TOP AND BOTTOM. TOP OF UPPER CABINET REF. TO INT. ELEVATIONS 0' - 3 255/256" 4" TYP 2'-0" TYP. UON (E) GYPSUM BOARD (E) WALL FRAMING - REFER TO FLOOR PLAN FOR WALL TYPES PROVIDE BLOCKING AT TOP & BOTTOM OF ALL UPPER BASE, AND FULL HEIGHT CABINETS, AND WALL HUNG ACCESSORIES. #14 X 3 1/2" F.H.W.S. @ 16" O.C. MAX #12 X 3" F.H.W.S. CABINET PER INTERIOR ELEVATIONS RUBBER BASE SCHEDULED FINISH FLOOR 6" X 1-1/4" X 16 GA. CONTINUOUS TRACK NOTCH & FASTEN TO STUDS W/ 4 #8 S.M.S. (E) WALL FRAMING (E) GYPSUM BOARD BACKSPLASH (WHERE OCCURS) BLOCKING LAMINATE COUNTERTOP FACE OF CABINET TOP OF COUNTER REF. TO INT. ELEVATIONS Sink (per Plans); Sealant around perimeter SECTION Note:Provide backing in wall framing as required for lower and upper cabinet support Stainless Steel Countertop Insulate exposed water supply and drain pipes; there shall be no sharp or abrasive surfaces under sink. PLAN Remove Doors or Pocket away provided min. 30" clr. width met 30" MIN. CLR. WORKSPACE @ WORKSTATION PER PLANS Finish Side Panels, Typ. Under Sink Sink (per Plans); Verify Basin Depth per Knee Clearance; Off-center Rear Drain; Install per Manuf. Specifications *Kitchen Accessibility Notes 1. The sink and work surface to be separate (30") components. 2. Base cabinet doors directly under the counter area, shall be removable without the use of specialized tools or specialized knowledge, or shall pocket away in order to provide clearance for a wheelchair. The finish floor beneath the counter area shall be extended to the rear panel. 3. With doors removed or pocketed away, toe and knee clearance to comply with detail: 4. Faucet controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. 5. The force required to activate controls shall be no greater than 5 pound force (22.2N). Lever-operated, push-type and electronically controlled mechanisms are examples of acceptable designs. Self- closing valves are allowed if the faucet remains open for at least 10 seconds. 34" MAX. Retractable hardware at sink cabinet base; doors pocket away or may be removed* Finish Interior Side Panels BETWEEN SIDE PANELS MIN. 30" CLR. 4" Under Sink 27" Min. Knee Clearance ELEVATION Finish Back and Insides of Cabinet TO REAR OF CABINET 2' - 0" Extend Finish Flooring Under Cabinet GYPSUM BOARD WALL FRAMING - REFER TO FLOOR PLANS FOR WALL TYPES SEMI-RECESSED CABINET - ATTACH PER MANUF. RECOMMENDATIONS. WRAP GYPSUM BOARD INTO OPENING MOUNT WITH OPERABLE PORTION OF CABINET OR EXTINGUISHER AT 48" MAX. A.F.F. 4" MAX C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DE T A I L S A-903 JH JR 6/20/24 JR SCALE: 1" = 1'-0"A-903 TYP. 2X BLOCKING2 SCALE: 1" = 1'-0"A-903 TYP. 4X BLOCKING1 SCALE: 1" = 1'-0"A-903 LAVATORY COUNTER8 SCALE: 3" = 1'-0"A-903 BASE CABINET4 SCALE: 3" = 1'-0"A-903 BASE CABINET ANCHORAGE3 SCALE: 3" = 1'-0"A-903 LAMINATE COUNTERTOP5 SCALE: 3/4" = 1'-0"A-413 A-903 ACC. KITCHEN WORKSTATION AND SINK9 SCALE: 3" = 1'-0"A-903 FIRE EXTINGUISHER7 9/13/24 SLOPE, TYP. WATERPROOF MEMBRANE FLOOR DRAIN - REFER TO PLUMBING PLANS SLOPE 2% MAX DRAIN SET FLUSH WITH FINISH FLOOR CERAMIC TILE OVER THINSET MORTAR AND MORTAR BED CARPET 1/4" - 3/8" (IF > 1/4" HIGH, THEN PROVIDE 1:2 BEVEL) 1/4" LUXURY VINYL TILE FINISH PER SCHEDULE STRAIGHT EDGE TRIM (E) CONCRETE SLAB MORTAR BED CERAMIC FLOOR TILE COVED CERAMIC FLOOR TILE CERAMIC TILE, THINSET OVER CEMENT BOARD OR M.R. GYP. BOARD AS SPECIFIED REFER TO INTERIOR ELEVS CERAMIC TILE BULL NOSE, THINSET OVER CEMENT BOARD OR M.R. GYP. BOARD AS SPECIFIED NOTE:SHADED ELEMENTS SHOWN ARE EXISTING TO REMAIN. RESILIENT BASE WALL FINISH 1/2" GYPSUM WALL BOARD FINISH FLOOR RESILIENT BASE WALL FINISH 1/2" GYPSUM WALL BOARD FINISH FLOOR (E) CONCRETE CURB, (N) WHERE OCCURS USE CONSTRUCTION ADHESIVE TO SECURE GWB TO CONCRETE CURB (E) CONC. SLAB (E) CONC. SLAB WITHOUT CURB WITH CURB 3/8" THROUGH-BOLTS WITH WASHERS ON BACKSIDE. TYP 6 MIN. CUT AROUND MOUNTING PLATE BACKING PER STRUCTURAL FRAMING STUD GYPSUM BOARD MOUNTING PLATE WALL MOUNTED DRINKING FOUNTAIN MOUNTING STUDS 0' - 8" C 40884 10-31-25 RENEWAL DATE A T C E TIHCRADESNECIL S T A T E OF C A L I F O R NI J O N A T H AN K C U OH 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION 2000577-04 As indicated DE T A I L S A-904 JH JR 6/20/24 JR SCALE: 3" = 1'-0"A-904 FLOOR DRAIN2 SCALE: 6" = 1'-0"A-904 CARPET TO LVT TRANSITION5 SCALE: 3" = 1'-0"A-904 BASE - INTERIOR - CT 4 SCALE: 3" = 1'-0"A-904 GWB TERMINATION AND BASE1 SCALE: 3" = 1'-0"A-904 DUAL WALL MOUNT FOUNTAIN6 9/13/24 MECHANICAL GENERAL NOTES 1 COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES: 2022 CALIFORNIA ADMINISTRATIVE CODE (CAC): PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA BUILDING CODE (CBC): PART 2, TITLE 24 CCR 2022 CALIFORNIA ELECTRICAL CODE (CEC): PART 3, TITLE 24 CCR 2022 CALIFORNIA MECHANICAL CODE (CMC): PART 4, TITLE 24 CCR 2022 CALIFORNIA PLUMBING CODE (CPC): PART 5, TITLE 24 CCR 2022 CALIFORNIA ENERGY CODE (CENC): PART 6, TITLE 24 CCR 2022 CALIFORNIA FIRE CODE (CFC): PART 9, TITLE 24 CCR 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN): PART 11, TITLE 24 CCR REPORT DEFICIENCIES WITHIN THIRTY (30) DAYS UPON AUTHORIZATION TO PROCEED. 2 THESE DRAWINGS ARE A GENERAL GRAPHIC PRESENTATION OF THE WORK. DUCTWORK, PIPING, AND EQUIPMENT, AS SHOWN, ARE SCHEMATIC. FABRICATE AND INSTALL BASED ON ACTUAL FIELD MEASUREMENT. COORDINATE WITH OTHER TRADES. ADHERE TO LOCATIONS AS CLOSELY AS POSSIBLE, VARY RUNS OR SHAPE OF DUCTWORK AS REQUIRED TO MEET STRUCTURAL AND OTHER INTERFERENCES AS REQUIRED BY THE ARCHITECT. PROVIDE A COMPLETE SET OF SHOP DRAWINGS REFLECTING ACTUAL DIMENSIONS, ACCESS REQUIREMENTS, AND DETAILS BASED UPON THE ACTUAL EQUIPMENT PROCURED. MAINTAIN AN UP TO DATE SET OF AS-BUILT DRAWINGS AT THE JOB SITE. 3 THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL ITEMS RELATED TO MECHANICAL SYSTEMS WITH THE WORK OF OTHER TRADES BEFORE PROCEEDING WITH PROCURING OR FABRICATION OF EQUIPMENT, DUCTWORK, PIPING ETC. ITEMS TO BE COORDINATED SHALL INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: GRILLES, REGISTERS AND DIFFUSERS SHALL BE COORDINATED WITH THE REFLECTED CEILING PLAN. DUCTWORK LOCATIONS AND POTENTIAL INTERFERENCES WITH STRUCTURAL MEMBERS, FRAMING, FIRE SPRINKLER LINES, PLUMBING WASTE LINES, CABLE TRAYS AND CONDUIT. ACCESS TO VOLUME DAMPERS FOR BALANCING. ACCESS TO ALL EQUIPMENT, AS WELL AS PLATFORM AND CURB LOCATIONS. 4 REVIEW ALL DRAWINGS AND SPECIFICATIONS INCLUDING ARCHITECTURAL, STRUCTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL. ANY QUESTIONS SHALL BE BROUGHT UP, IN WRITING, TO THE ATTENTION OF THE ENGINEER BEFORE THE START OF CONSTRUCTION. 5 REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF DIFFUSERS, REGISTERS, GRILLES, AND ACCESS PANELS. 6 ALL DUCT DIMENSIONS, AS SHOWN ON MECHANICAL DRAWINGS ARE CLEAR INSIDE DIMENSIONS. INCREASE OUTER DUCT DIMENSION AS REQUIRED TO ACCOUNT FOR THE THICKNESS OF INTERNAL LINING WHERE APPLICABLE. 7 INSULATION AND FLEXIBLE DUCT SHALL COMPLY WITH STATE FIRE MARSHALL CRITERIA AND SHALL NOT EXCEED FLAME SPREAD OF 25 AND SMOKE DEVELOPED OF 50 PER ASTM-84, NFPA-223, AND UL 723. 8 INSULATE PIPING AND DUCTWORK IN ACCORDANCE TO THE GOVERNING CODES. 9 ALL SQUARE ELBOWS IN SUPPLY DUCTWORK SHALL HAVE TURNING VANES. PROVIDE MANUAL VOLUME DAMPER AT EACH BRANCH DUCT TAKE-OFF SERVING EACH AIR TERMINAL DEVICE. PROVIDE BALANCING DAMPERS FOR EACH MAIN DUCT TAKE-OFF IN ACCORDANCE TO SMACNA IN ORDER TO ASSURE A COMPLETELY BALANCED SYSTEM. 10 MATERIALS EXPOSED WITHIN ANY SPACE BEING USED AS AN AIR PLENUM SHALL BE NON COMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE DEVELOPED INDEX NOT GREATER THAN 50, WHEN TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ONE OF THE FOLLOWING TEST METHODS: NFPA 255, METHOD OF TEST OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, ASTM E84, SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, OR UL 723, TEST FOR SURFACE BURNING CHARACTERISTIC OF BUILDING MATERIALS. PLUMBING GENERAL NOTES 1 COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES: 2022 CALIFORNIA ADMINISTRATIVE CODE (CAC): PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) 2022 CALIFORNIA BUILDING CODE (CBC): PART 2, TITLE 24 CCR 2022 CALIFORNIA ELECTRICAL CODE (CEC): PART 3, TITLE 24 CCR 2022 CALIFORNIA MECHANICAL CODE (CMC): PART 4, TITLE 24 CCR 2022 CALIFORNIA PLUMBING CODE (CPC): PART 5, TITLE 24 CCR 2022 CALIFORNIA ENERGY CODE (CENC): PART 6, TITLE 24 CCR 2022 CALIFORNIA FIRE CODE (CFC): PART 9, TITLE 24 CCR 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN): PART 11, TITLE 24 CCR REPORT DEFICIENCIES WITHIN THIRTY (30) DAYS UPON AUTHORIZATION TO PROCEED. 2 NO PLUMBING SHALL BE INSTALLED UNTIL ALL REQUIRED PLUMBING PLAN CHECK PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM ALL REQUIRED AGENCIES. 3 LAVATORY FAUCETS, SINK FAUCETS (NOT INCLUDING SERVICE SINK FAUCETS OR FAUCETS DESIGNATED AS INSTITUTIONAL) SHALL MEET THE FLOW REQUIREMENTS OUTLINED IN THE APPLIANCE EFFICIENCY STANDARDS. 4 COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF PLUMBING FIXTURES AND DRAINS. 5 PROVIDE ALL TAILPIECES, TRAPS, STOPS, AND SUPPLY PIPES TO LAVATORIES DESIGNED AS ACCESSIBLE, WITH PREFORMED INSULATION JACKET. 6 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF WALLS, ROOFS, FOOTINGS, FLOORS, INCLUDING ALL SAW CUTTING AND CORE DRILLING. COORDINATE ALL SAW CUTTING AND CORE DRILLING WITH STRUCTURAL DRAWINGS. ANY CUTTING AND DRILLING REQUIRED OF STRUCTURAL ELEMENTS THAT IS NOT SPECIFICALLY SHOWN ON THE PLANS SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION PRIOR TO CUTTING AND DRILLING. CONTRACTOR SHALL SUBMIT PROPOSED LOCATION AND SIZES OF SUCH CUTTING AND DRILLING FOR THE ARCHITECTS AND STRUCTURAL ENGINEERS APPROVAL. 7 COORDINATE INSTALLATION OF ALL EQUIPMENT AND PIPING WITH OTHER TRADES PRIOR TO INSULATION. ENSURE THAT ALL CONTROL DEVICES, SHUT-OFF VALVES, ETC. ARE ACCESSIBLE FOR MAINTENANCE. WHERE ACCESS PANELS IN FINISHED SPACES, OTHER THAN THAT SHOWN, CONTRACTOR SHALL PROVIDE AND COORDINATE EXACT LOCATION OF PANELS WITH ARCHITECT PRIOR TO INSTALLATION. 8 ANY STRUCTURAL FIREPROOFING DAMAGED DURING INSTALLATION OF PLUMBING EQUIPMENT, PIPING, ETC. SHALL BE REPAIRED AT NO COST TO THE OWNER. REPAIRS SHALL BE AS DIRECTED BY THE ARCHITECT. 9 NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE PER 2022 CPC 609.10. THE METHOD TO BE FOLLOWED SHALL BE THAT PRESCRIBED BY THE HEALTH AUTHORITY OR, IN CASE NO METHOD IS PRESCRIBED BY IT, THE FOLLOWING: A)THE PIPE SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE WATER UNTIL POTABLE WATER APPEARS AT THE POINTS OF OUTLET. B)THE SYSTEM OR PARTS THEREOF SHALL BE FILLED WITH A WATER-CHLORINE SOLUTION CONTAINING NOT LESS THAN 50 PARTS PER MILLION OF CHLORINE, AND THE SYSTEM OR PART THEREOF SHALL BE VALVED-OFF AND ALLOWED TO STAND FOR 24 HOURS; OR, THE SYSTEM OF PART THEREOF SHALL BE FILLED WITH A WATER-CHLORINE SOLUTION CONTAINING NOT LESS THAN 200 PARTS PER MILLION OF CHLORINE AND ALLOWED TO STAND FOR 3 HOURS. C)FOLLOWING THE ALLOWED STANDING TIME, THE SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE WATER UNTIL THE CHLORINE RESIDUAL IN THE WATER COMING FROM THE SYSTEM DOES NOT EXCEED THE CHLORINE RESIDUAL IN THE FLUSHING WATER. D)THE PROCEDURE SHALL BE REPEATED WHERE IT IS SHOWN BY BACTERIOLOGICAL EXAMINATION MADE BY AN APPROVED AGENCY THAT CONTAMINATION PERSISTS IN THE SYSTEM. MECHANICAL LEGEND SYMBOL ABBREVIATION DESCRIPTION Ø DIA DIAMETER ɸ ELECTRICAL PHASE CEILING MOUNTED SUPPLY OR OUTSIDE AIR DIFFUSER CEILING MOUNTED RETURN AIR GRILLE CEILING MOUNTED EXHAUST AIR GRILLE SIDEWALL MOUNTED SUPPLY AIR DIFFUSER, RETURN AIR GRILLE, LOUVER 24X12, 24X12 FO RECTANGULAR, FLAT OVAL DUCT 24X12L, 12ØL LINED DUCT RECTANGULAR SUPPLY / OA, RETURN, EXHAUST / RELIEF DUCT PASSING THROUGH PLAIN OF VIEW RECTANGULAR SUPPLY / OA, RETURN, EXHAUST / RELIEF DUCT TURNING DOWN 12Ø ROUND DUCT ROUND DUCT TURNING DOWN, ROUND DUCT TURNING UP 90° ELBOW WITH TURNING VAINS FLEXIBLE DUCT 60" MAX LENGTH FC FLEXIBLE CONNECTION VD MANUAL VOLUME DAMPER CVD CABLE OPERATED VOLUME DAMPER ACCESS CLEARANCE POC OR POD POINT OF CONNECTION, POINT OF DISCONNECTION ITEMS RELATED TO THE MECHANICAL SYSTEM TO BE REMOVED MECHANICAL ABBREVIATIONS AC AIR CONDITION, AIR CONDITIONING, AIR CONDITIONED HP HORSE POWER ABV ABOVE HVI HOME VENTILATING INSTITUTE AFF ABOVE FINISHED FLOOR HZ HERTZ AFUE ANNUAL FUEL UTILIZATION EFFICIENCY IDU INDOOR UNIT AHJ AUTHORITY HAVING JURISDICTION IWC INCHES OF WATER COLUMN AHU AIR HANDLING UNIT KW KILOWATT ALUM ALUMINUM LBS POUNDS AMCA AIR MOVEMENT AND CONTROL ASSOCIATION LWT LEAVING WATER TEMPERATURE AMB AMBIENT MBH 1000 BRITISH THERMAL UNITS PER HOUR AP ACCESS PANEL MCA MINIMUM CIRCUIT AMPS ARCH ARCHITECT, ARCHITECTURAL MFGR MANUFACTURE OR MANUFACTURER ARI AMERICAN REFRIGERATION INSTITUTE MIN MINIMUM ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS MUA MAKE-UP AIR BDD BACK DRAFT DAMPER (N)NEW BOD BASIS OF DESIGN NL NOT LISTED BEL BELOW NOM NOMINAL BHP BREAK HORSE POWER NTS NOT TO SCALE BLDG BUILDING OA OUTSIDE AIR BTUH BRITISH THERMAL UNIT PER HOUR OAI OUTSIDE AIR INTAKE CA COMBUSTION AIR OBD OPPOSED BLADE DAMPER CD CONDENSATE DRAIN ODU OUTDOOR UNIT CFD CEILING FIRE DAMPER OSHPD OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT CFM CUBIC FEET PER MINUTE PD PRESSURE DROP CONT CONTINUATION PSI POUNDS PER SQUARE INCH CSD CEILING SMOKE DAMPER RA RETURN AIR DB DRY BULB TEMPERATURE REFRIG REFRIGERANT, REFRIGERATION DN DOWN RM ROOM DSA DIVISION OF THE STATE ARCHITECT RPM REVOLUTIONS PER MINUTE DTR DOWN THROUGH ROOF SA SUPPLY AIR (E)EXISTING SEER SEASONAL ENERGY EFFICIENCY RATION EA EXHAUST AIR SHT SHEET EC EVAPORATIVE COOLER SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION EDB ENTERING DRY BULB TEMPERATURE SOV SHUT OFF VALVE EER ENERGY EFFICIENCY RATIO SP STATIC PRESSURE EFF EFFICIENCY SS STAINLESS STEEL ELEC ELECTRICAL SSE STEADY STATE EFFICIENCY ESP EXTERNAL STATIC PRESSURE SST SATURATED SUCTION TEMPERATURE EWB ENTERING WET BULB TEMP TEMPORARY, TEMPERATURE EWT ENTERING WATER TEMPERATURE TSP TOTAL STATIC PRESSURE FA FROM ABOVE TYP TYPICAL FC FLEXIBLE CONNECTION TXV THERMAL EXPANSION VALVE FD FIRE DAMPER UON UNLESS OTHERWISE NOTED FLA FULL LOAD AMPS UTR UP TO OR UP THROUGH ROOF FPM FEET PER MINUTE VD VOLUME DAMPER FSC FAN SPEED CONTROLLER VEX VEHICLE EXHAUST SYSTEM FSD FIRE/SMOKE DAMPER VRF VARIABLE REFRIGERANT VOLUME GA GAGE, GAUGE WB WET BULB TEMPERATURE GALV GALVANIZED WC WATER COLUMN GPM GALLONS PER MINUTE WG WATER GAUGE GYP GYPSUM WT WEIGHT EXPRESSED IN POUNDS HD HEAD PLUMBING ABBREVIATIONS ABV ABOVE HD HEAD ADA AMERICANS WITH DISABILITIES ACT HP HORSE POWER AFF ABOVE FINISHED FLOOR HZ HERTZ AG ABOVE GRADE IE INVERT ELEVATION AHJ AUTHORITY HAVING JURISDICTION IWC INCHES OF WATER COLUMN ALUM ALUMINUM KW KILOWATTS AMB AMBIENT LAV LAVATORY AMP AMPERAGE LBS POUNDS ARCH ARCHITECT, ARCHITECTURAL LWT LEAVING WATER TEMPERATURE BEL BELOW MAX MAXIMUM BF BELOW FLOOR MBH 1000 BRITISH THERMAL UNITS PER HOUR BG BELOW GRADE MCA MINIMUM CIRCUIT AMPS BFP BACKFLOW PREVENTOR MECH MECHANICAL BLDG BUILDING MFGR MANUFACTURE OR MANUFACTURER BOD BASIS OF DESIGN MIN MINIMUM BTUH BRITISH THERMAL UNIT PER HOUR MU MAKE-UP CA COMBUSTION AIR (N)NEW CD CONDENSATE DRAIN NOM NOMINAL CFH CUBIC FEET PER HOUR NPS NOMINAL PIPE SIZE CONN CONNECTION NTS NOT TO SCALE CONT CONTINUATION OPT OPERATING CI CAST IRON OSHPD OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT CP CHROME PLATED PD PRESSURE DROP DFU DRAINAGE FIXTURE UNITS PH PHASE DN DOWN PSI POUNDS PER SQUARE INCH DSA DIVISION OF THE STATE ARCHITECT PW PROCESS WASTE (E)EXISTING RM ROOM EC EVAPORATIVE COOLER RPM REVOLUTIONS PER MINUTE EFF EFFICIENCY SDL STORM DRAIN LEADER ELEC ELECTRICAL SDO STORM DRAIN OVERFLOW EQPT EQUIPMENT SHT SHEET EWT ENTERING WATER TEMPERATURE SOV SHUT OFF VALVE FA FROM ABOVE SS STAINLESS STEEL FC FLEXIBLE CONNECTION TEMP TEMPORARY, TEMPERATURE FLA FULL LOAD AMPS TYP TYPICAL FLR FLOOR UON UNLESS OTHERWISE NOTED FPS FEET PER SECOND UTR UP TO OR UP THROUGH ROOF FR FROM V VENT FT FLUSH TANK VAC VACUUM FV FLUSH VALVE VTR VENT THROUGH ROOF GA GAGE OR GAUGE WC WATER CLOSET GALV GALVANIZED W WASTE GPC GALLONS PER CYCLE W/WITH GPF GALLONS PER FLUSH W/O WITHOUT GPM GALLONS PER MINUTE WSFU WATER SUPPLY FIXTURE UNIT GYP GYPSUM WT WEIGHT EXPRESSED IN POUNDS GW GREASE WASTE SHEET INDEX SHEET NUMBER SHEET TITLE MP-000 MECHANICAL & PLUMBING GENERAL MP-001 MECHANICAL & PLUMBING SCHEDULES MP-002 MECHANICAL & PLUMBING DETAILS EC-000 ENERGY COMPLIANCE DOCUMENTATION MPD-101 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN MPD-102 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN MP-200 MECHANICAL & PLUMBING FIRST FLOOR PLAN MP-300 MECHANICAL & PLUMBING SECOND FLOOR PLAN PLUMBING LEGEND SYMBOL ABBREVIATION DESCRIPTION BALL VALVE BFV BUTTERFLY VALVE CAP CHECKVALVE COTG CLEAN OUT THROUGH GRADE Ø DIA DIAMETER ɸ ELECTRICAL PHASE FCO FLOOR CLEAN OUT SHUT OFF VALVE IN PIPE DROP OR PIPE RISER YB SHUT OFF VALVE IN YARD BOX STRAINER TPV TRAP PRIMER VALVE UNION PIPE DOWN PIPE UP PIPE TEE DOWN PIPE INTERSECTION PLUG VALVE ELEVATION VIEW PV PLUG VALVE PLAN VIEW POC OR POD POINT OF CONNECTION OR POINT OF DISCONNECT PRV PRESSURE REDUCING OR REGULATOR VALVE WCO WALL CLEANOUT CW COLD WATER CD CONDENSATE DRAIN HW HOT WATER V SANITARY VENT TP TRAP PRIMER S/W WASTE (ABOVE GRADE) S/W WASTE (BELOW GRADE) S/W EXISTING WASTE WCO CD TP TP PROJECT TEAM LIST TITLE NAME DESK NUMBER EMAIL ADDRESS PROJECT MANAGER DENVER STANGER 805.540.5388 DSTANGER@3CENG.COM MECHANICAL DESIGNER DENVER STANGER 805.540.5388 DSTANGER@3CENG.COM PLUMBING DESIGNER RANDY CARMINATI 805.540.3363 EXT 319 RCARMINATI@3CENG.COM CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g L e a d S h e e t s . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T ME C H A N I C A L & P L U M B I N G G E N E R A L MP-000 COMMERCIAL GRILLE, REGISTER, DIFFUSER, LOUVER SCHEDULE TAG TYPE MAKE MODEL BORDER TYPE CONSTRUCTION FINISH IMAGE REMARKS INSTALLATION DETAILGYP BOARD CEILING OR WALL LAY-IN CEILING CEILING SUPPLY TITUS TDC 1 3 STEEL WHITE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND FRAMING CONTRACTOR TO INSURE OPENINGS IN HARD CEILINGS AND WALLS ARE CORRECTLY SIZED TO ACCOMMODATE THE SPECIFIED BORDER TYPE. NO EXCEPTIONS 3/MP-002 CEILING OR SIDEWALL RETURN AND EXHAUST TITUS 350RL 1 3 STEEL WHITE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND FRAMING CONTRACTOR TO INSURE OPENINGS IN HARD CEILINGS AND WALLS ARE CORRECTLY SIZED TO ACCOMMODATE THE SPECIFIED BORDER TYPE. NO EXCEPTIONS SEE 3/MP-002 FOR DUCTED EXHAUST AIR GRILLES SEE 4/MP-002 FOR PLENUM RETURN AIR GRILLES CEILING SUPPLY DEFLECTION LEGEND (EXCEPT FOR 4-WAY DEFLECTION, SHADING INDICATES ACTIVE SECTION OF DIFFUSER) 2-WAY CORNER 2-WAY OPPOSITE 1-WAY3-WAY4-WAY 12x12S1400 NECK SIZE (length x width or length x height) CFMFDFD = FIRE DAMPER FSD = FIRE/SMOKE DAMPER OAI = OUTSIDE AIR INTAKE X"Ø = INLET SIZE (IF APPLICABLE) DIFFUSER, GRILLE, LOUVER MARK: S = SUPPLY; R = RETURN; E = EXHAUST; T = TRANSFER; L = LOUVER; O = OUTSIDE AIR S1S1S1S1 R1 E1 PLUMBING FIXTURE SCHEDULE TAG FIXTURE BRANCH SIZE ELECTRICAL MODEL & FITTINGS W V CW HW DF-1 DRINKING FOUNTAIN - ACCESSIBLE 2"1-1/2"1/2"NA NA DUAL HEIGHT DRINKING FOUNTAIN WITH BOTTLE FILLER, HAWS #1117LN-1920, IN WALL MOUNTED, STEEL MOUNTING PLATE, STAINLESS STEEL BOTTLE FILLER, PROVIDE WITH STOPS AND SUPPLIES, INSTALL PER ACCESSIBLE FACILITY REQUIREMENTS. IMS-1 ICE MAKER SUPPLY NA NA 1/2"NA NA OATEY #39152, 6"X6"X3-3/8" PLASTIC BOX RECESSED IN WALL W/BRASS QUARTER TURN VALVE. PROVIDE WITH WATER HAMMER ARRESTOR. LAV-1 LAVATORY - ACCESSIBLE 2"1-1/2"1/2"1/2"BATTERY WALL MOUNTED, AMERICAN STANDARD #0356.421, VITREOUS CHINA, WHITE. SLOAN FAUCET #EBF-85, 0.35 GPM, SENSOR OPERATED. PROVIDE STOPS, SUPPLIES, C.P. BRASS "P" TRAP, & WATTS WALL SUPPORT #TCA-411. S-1 SINK 2"1-1/2"1/2"1/2"NA COUNTER MOUNTED, JUST #SL-ADA 2131-A65-J, 21-1/4"X31"X6-1/2" 18 GA. STAINLESS, SINGLE BOWL. PROVIDE WITH T&S BRASS FAUCET #S-2770, STRAINER, STOPS, SUPPLIES & C.P. BRASS "P" TRAP. UR-1 URINAL 2"1-1/2"1-1/4"NA BATTERY WALL MOUNTED, AMERICAN STANDARD PINTBROOK #6002.001, SENSOR OPERATED, 0.125 GPF, 14-7/16"X14-5/16"X22-5/8", VITREOUS CHINA, WHITE. PROVIDE WITH SLOAN "SOLIS" FLUSH VALVE #8186, 0.125 GPF. WC-1 WATER CLOSET - ACCESSIBLE 3"2"1-1/4"NA BATTERY FLOOR MOUNTED, AMERICAN STANDARD MADERA #3043.001, ELONGATED, SENSOR OPERATED, 26-3/4"X14"X17" RIM, VITREOUS CHINA, WHITE. PROVIDE WITH SLOAN FLUSH VALVE #8111-1.1-OR, 1.1 GPF AND & BEMIS OPEN FRONT SEAT #1955SSCT-000. INSTALL PER ACCESSIBLE FACILITIES REQUIREMENTS, LOCATE HANDLE ON WIDE SIDE OF FIXTURE WC-2 WATER CLOSET 3"2"1-1/4"NA BATTERY FLOOR MOUNTED, AMERICAN STANDARD MADERA #2234.001, ELONGATED, SENSOR OPERATED, 26-3/4"X14"X15" RIM, VITREOUS CHINA, WHITE. PROVIDE WITH SLOAN FLUSH VALVE #8111-1.1-OR, 1.1 GPF AND & BEMIS OPEN FRONT SEAT #1955SSCT-000. LOCATE HANDLE ON WIDE SIDE OF FIXTURE NOTES:1. DATA GIVEN IN SCHEDULE PROVIDES CODE REQUIRED FLOW RATES AND MINIMUM BRANCH PIPING SIZES. 2. BRANCH LINE SIZE MINIMUMS ARE TO BE AS SPECIFIED IN THIS CHART UNLESS OTHERWISE NOTED. CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g L e a d S h e e t s . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T ME C H A N I C A L & P L U M B I N G S C H E D U L E S MP-001 DUCTLESS SPLIT SYSTEM HEAT PUMP SCHEDULE TAG MAKE NOM TONS SENSIBLE COOLING REFRIGERANT AHRI PERFORMANCE INDOOR UNIT OUTDOOR UNIT REMARKS SEE BELOW COOLING HEATING BTUH SEER2 EER2 BTUH AT 47°F BTUH AT 17°F HSPF2 MODEL INSTALLATION TYPE POWER V/ɸ/HZ MCA MOCP CFM WATTS >HP@ OPERATING WEIGHT LBS INSTALLATION DETAIL MODEL POWER V/ɸ/HZ MCA MOCP OPERATING WEIGHT LBS INSTALLATION DETAIL DAIKIN 1.5 13,700 R-410A 18,000 16.9 11.9 20,000 13,800 7.6 FAQ18TAVJU HIGH WALL 208/1/60 0.5 15 500 43 35 2/MP-002 RZQ18TBVJUA 208/1/60 16.5 20 175 1/MP-002 C1 GENERAL NOTES APPLICABLE TO ALL UNITS: A. DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR. B. UNIT SHALL BE CONFIGURED FOR COOLING ONLY. C. SIZE REFRIGERATION LINES PER THE MANUFACTURERS REQUIREMENTS FOR TOTAL DEVELOPED LINE LENGTH. D. PROVIDE WITH MANUFACTURERS CONDENSER WALL MOUNTING BRACKET. CONTROL NOTES: C1. PROVIDE WITH MANUFACTURERS MODEL BRC1E73 WIRED CONTROLLER. DS 1 VENTILATION CALCULATION System Tag Room Name Room Area (SQFT) Table 120.1-A Occupancy Category Table 120.1-A Area Outdoor Air Rate (cfm/sqft) CFM Requirement: 120.1(c)3 (E ) A C U n i t T h a t S e r v e s t h e F i r s t F l o o r Bureau Sargeant 107 149 Office Buildings - Office space 0.15 23 Shared Office 126 354 Office Buildings - Office space 0.15 54 Open Office 102 1848 Office Buildings - Office space 0.15 278 North Stair 1F 151 General - Corridors 0.15 23 South Stair 1F 151 General - Corridors 0.15 23 Hall (Adjacent to Stairs)43 General - Corridors 0.15 7 Lobby 100 260 General - Corridors 0.15 39 Hall 114/115 131 General - Corridors 0.15 20 Break Room 121 240 Office Buildings - Breakrooms 0.5 120 Briefing Room 122 806 General - Conference/meeting 0.5 403 Incident Com. 123 125 Office Buildings - Office space 0.15 19 Dispatch 124 86 Office Buildings - Office space 0.15 13 Meeting 125 126 General - Conference/meeting 0.5 63 TOTAL 1085 (E ) A C U n i t T h a t S e r v e s t h e S e c o n d f l o o r Int Affairs Lieut. 224 266 Office Buildings - Office space 0.15 40 Break Room 207 244 Office Buildings - Breakrooms 0.5 122 BOS. Manager 208 129 Office Buildings - Office space 0.15 20 Public Affairs Manager 205 134 Office Buildings - Office space 0.15 21 Meeting Room 202 133 General - Conference/meeting 0.5 67 North Stair 2F 154 General - Corridors 0.15 24 South Stairs and Hallway 2F 457 General - Corridors 0.15 69 Train/Hiring Manager 208 132 Office Buildings - Office space 0.15 20 Crime Analyst 209 129 Office Buildings - Office space 0.15 20 Conf. 202 679 General - Conference/meeting 0.5 340 Conf. 202 Hall/Flex Spaces 646 General - Corridors 0.15 97 Break Room 215 262 Office Buildings - Breakrooms 0.5 131 Chief 214C 452 Office Buildings - Office space 0.15 68 Admin 214A 265 Office Buildings - Office space 0.15 40 Dept. Chief 213 155 Office Buildings - Office space 0.15 24 Dept. Chief 211 139 Office Buildings - Office space 0.15 21 TOTAL 1124 NOTES: AFTER COMPLETION OF CONSTRUCTION AND PRIOR TO OCCUPANCY THE OUTSIDE AIR INTAKE AT THE (E) AC UNITS SHALL BE BALANCED AS FOLLOWS: FIRST FLOOR AC UNIT: BALANCE OUTSIDE AIR INTAKE TO 1100 CFM SECOND FLOOR AC UNIT: BALANCE OUTSIDE AIR INTAKE TO 1125 CFM 1 CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g L e a d S h e e t s . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T ME C H A N I C A L & P L U M B I N G D E T A I L S MP-002NTS RETURN AIR GRILLE INTO PLENUM4 14x12L DUCT LINER PER SPECIFICATIONS 24 GAUGE CAN 1/2" GALVANIZED STEEL MESH SCREEN OVER OPENING REFER TO DETAIL 3/MP-002 FOR GRILLE SUPPORT NTS DIFFUSER OR GRILLE INSTALLATION (LAY-IN CEILING)3 CEILING GRID DIFFUSER OR GRILLE 24 GAGE DIFFUSER CAN DUCT INSULATION PER SPECIFICATIONS 2" WIDE, 4" LONG 24 GAUGE CLIP SECURED TO DIFFUSER CAN WITH #12 TEK SCREW #12 SLACK SAFETY WIRE AT DIAGONAL CORNERS WITH (4) TIGHT TURNS IN 112" DUCT INSULATION PER SPECIFICATIONS CONICAL FITTING WITH BEAD FOR FLEXIBLE DUCT CONNECTION FLEXIBLE DUCT 60" MAX LENGTH, REFER TO DETAIL 5/MP-002 FOR ATTACHMENT 24 GAGE DIFFUSER CAN ATTACH DIFUSER OR GRILLE TO CAN WITH (8)#12 TEK SCREWS (2) PER SIDE EQUALLY SPACED #12 SLACK SAFETY WIRE REFER TO ARCHITECTURAL DETAILS FOR UPPER CONNECTION 1 1 MIN MINIMUM 2" LONG COLLAR WITH BEAD FOR FLEXIBLE DUCT CONNECTION ADAPTER TO NECK SIZE 1-1/2 RADIUS ELBOW SIDE DUCT CONNECTION TOP DUCT CONNECTION DUCT INSULATION PER SPECIFICATIONS TOP DUCT CONNECTION SHALL BE USED WHERE SPACE PERMITS. ONLY USE SIDE DUCT CONNECTION WHERE VERTICAL CLEARANCE IS LIMITED. DIFFUSER SUPPORT NOTES ARE APPLICABLE TO BOTH DUCT CONNECTION CONFIGURATIONS NTS HIGH WALL FAN COIL MOUNTING2 MOUNTING BRACKET SUPPLIED WITH UNIT, MOUNT TO BLOCKING IN WALL WITH (9) M8 WOOD SCREWS MINIMUM 1-1/2" EMBEDMENT INTO BLOCKING CONDENSATE DRAIN IF NOT PUMPED REFRIGERATION LINES AND CONDENSATE DRAIN WHEN PUMPED STUD (TYP) 4x4 BLOCKING IN WALL (TYP) OUTLINE OF FAN COIL OUTLINE OF FAN COIL 35 LBS MAX NTS FLEXIBLE DUCT CONNECTION5 STAINLESS STEEL WORM GEAR CLAMP OVER (2) WRAPS OF UL-181 DUCT TAPE STEP - 1: FOLD BACK JACKET AND INSULATION. SLIDE AT LEAST 1" OF CORE OVER DUCT AND PAST THE BEAD. SEAL CORE TO DUCT WITH AT LEAST (2) WRAPS OF UL-181 LISTED DUCT TAPE. SECURE CONNECTION WITH A CLAMP PLACED OVER THE CORE AND TAPE PAST THE BEAD. OUTSIDE JACKET INSULATION WIRE HELIX AND LINING CORE OUTSIDE JACKET INSULATION OUTSIDE JACKET INSULATION WIRE HELIX AND LINING CORE WIRE HELIX AND LINING CORE STEP - 2: PULL THE INSULATION AND JACKET OVER THE TOP OF THE CORE AND THE CLAMP. TUCK THE OUTSIDE JACKET UNDER THE INSULATION. STEP - 3: INSTALL A CLAMP AROUND THE ENTIRE FLEXIBLE DUCT ASSEMBLY STAINLESS STEEL WORM GEAR CLAMP DUCT DUCT DUCT 24" MIN NTS ROUND VOLUME DAMPER6 WING NUT DAMPER REGULATOR SET 10"Ø AND SMALLER: NO.KSR 12"Ø TO 20"Ø: NO.KSR 21"Ø AND LARGER: NO.KS-12 ALL SETS TO BE "QUADRANT" TYPE HANDLE DUCT PENETRATIONS SHALL BE SEALED AIR TIGHT. ALL MODEL NUMBERS LISTED ARE DURO DYNE. 1/8" CLEARANCE BETWEEN DAMPER AND DUCT ALL AROUND ROD CONTINUOUS ON ALL DAMPERS OVER 10"Ø DAMPER, OPPOSED BLADE OR SINGLE LEAF TYPE OUTSIDE CLOSED END BEARING NO. SB, SIZE AS REQUIRED PLAN ELEVATION WALL ESCUTCHEON (TYP.) 'P'- TRAP HOSE CLAMP (TYP.) WYE BRANCH TAILPIECE SINK NTS CONDENSATE TO TAIL PIECE DETAIL 7 ALL CONDENSATE PIPING SHALL BE TYPE L COPPER AND INSULATED WITH 1/2" INSULATION NEOPRENE HOSE SAME SIZE AS CONDENSATE DRAIN CONDENSATE DRAIN LINE IN WALL NTS HIGH-WALL FANCOIL CONDENSATE DRAIN8 CEILING HIGH-WALL FANCOIL UNIT CONDENSATE PUMP WITH INTEGRAL CHECK VALVE, REFER TO MECHANICAL PLANS ADAPTOR AS REQUIRED COPPER FEMALE THREADED ADAPTOR WALL HE I G H T S H A L L N O T E X C E E D HE A D C A P A B I L I T Y O F P U M P 12 " M I N CONNECT TO TOP OF GRAVITY DRAINED CONDENSATE PIPE (TYP) SLOPE TO DRAIN, REFER TO PLANS FOR SIZE WALL PENETRATION BEHIND FANCOIL UNIT, DO NOT RUN PIPING EXPOSED PROVIDE OPEN VENT ON UPPERMOST UNIT IN ACCESSIBLE LOCATION ALL CONDENSATE PIPING SHALL BE TYPE L COPPER AND INSULATED WITH 1/2" INSULATION NTS CONDENSING UNIT - WALL MOUNTING BRACKET1 CONDENSER 3'' MIN.(E) CMU PARAPET WALL 1/4" DIA. 'TITEN HD SS' ANCHOR, MIN 2-1/2" EMBEDMENT (TYP OF 2 EACH BRACKET) (MAX WEIGHT 175 LBS) 40" MAX 4" MIN 12" MIN 8" MIN VERIFY IN FIELD EPDM GASKET 1/2" ROUND, 3/32" THICK, FLAT SS WASHER MOUNTING LEG INTEGRAL TO CONDENSING UNIT MOUNTING BRACKET (TYP OF 2) FASTEN CONDENSER WITH HARDWARE PROVIDED WITH MOUNTING BRACKET (E) SINGLE PLY ROOFING (E) SINGLE PLY ROOF SURFACE CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g L e a d S h e e t s . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T EN E R G Y C O M P L I A N C E D O C U M E N T A T I O N EC-000 UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 (E)18Ø (E)14Ø (E)14Ø (E)S (E)S (E)S (E)S POD(E)R (E)R (E)R (E)R 1 1 1 1 1 1 1 2 3 4 (E)E150 (E)E150 (E)S100 (E)S100 1 1 1 1 7 7 7 7 (E)R 1 5 6 5 1 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN SCALE:1/8" = 1'-0" DEMOLITION KEY NOTES APPLICABLE TO THIS SHEET ONLY GRILLE/DIFFUSER TO BE REMOVED AND DISCARDED. REMOVE ALL DUCTWORK UPSTREAM OF POD. (E) LAV TO BE REMOVED. PIPING TO REMAIN. (E) URINAL TO BE REMOVED. CAP PIPING IN WALL. (E) FIXTURE TO BE REMOVED. PIPING TO REMAIN. REMOVE (E) STAND PIPE AND ASSOCIATED STOPS. CAP PIPING UNDER CABINET. DISCONNECT DUCT FROM GRILLE/DIFFUSER. CAP DUCT TO KEEP CLEAN UNTIL RECONNECTION TO NEW GRILLE/DIFFUSER. 1 2 3 4 5 6 7 DEMOLITION PLAN STATEMENT THIS DEMOLITION PLAN WAS PREPARED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT REPRESENT THAT ALL ITEMS WHICH MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. DISPOSE OF ALL EQUIPMENT PER THE OWNER'S DIRECTION WHILE COMPLYING WITH ALL LOCAL CODES AND ORDINANCES. ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE. CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g P l a n . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T ME C H A N I C A L & P L U M B I N G D E M O L I T I O N F I R S T F L O O R P L A N MPD-101 T (E)S650 (E)S650 (E)S 325 (E)S250 (E)18Ø (E)14Ø (E)18Ø (E)S100 (E)10Ø (E)6Ø (E)10Ø (E)10Ø (E)14Ø UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 POD POD (E)R POD (E)R 1 2 1 1 1 2 1 3 (E)R (E)E200 (E)S 150 (E)S200 (E)R (E)E250 1 1 1 1 1 1 4 4 4 4 5 6 6 6 6 6 6 6 6 1 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN SCALE:1/8" = 1'-0" DEMOLITION KEY NOTES APPLICABLE TO THIS SHEET ONLY GRILLE/DIFFUSER TO BE REMOVED AND DISCARDED. REMOVE ALL DUCTWORK UPSTREAM OF POD. (E)FIXTURE TO BE REMOVED. CAP PIPING IN WALL AND BELOW FLOOR. DISCONNECT DUCT FROM GRILLE/DIFFUSER. CAP DUCT TO KEEP CLEAN UNTIL RECONNECTION TO NEW GRILLE/DIFFUSER (E)EXHAUST FAN TO BE REMOVED. DISCONNECT FROM POWER AND DUCTWORK. CAP DUCT AIR TIGHT. (E) FIXTURE TO BE REMOVED. PIPING TO REMAIN. 1 2 3 4 5 6 DEMOLITION PLAN STATEMENT THIS DEMOLITION PLAN WAS PREPARED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT REPRESENT THAT ALL ITEMS WHICH MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. DISPOSE OF ALL EQUIPMENT PER THE OWNER'S DIRECTION WHILE COMPLYING WITH ALL LOCAL CODES AND ORDINANCES. ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE. CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g P l a n . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T ME C H A N I C A L & P L U M B I N G D E M O L I T I O N S E C O N D F L O O R P L A N MPD-102 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 MEETING 125 DISPATCH 124 LOBBY 100 STORAGE 111 SHARED OFFICE 126 BUREAU SERGEANT 107 DETECTIVE EQUIPMENT 106 DRONE/EQUIP STORAGE 105OPEN OFFICE 102 MEN 118 JAN. 117 HALL 115 WOMEN 119 BREAK ROOM 121 ELECTRICAL 120 INCIDENT COM. 123 BRIEFING ROOM 122 ELEVATOR 127 (E)18Ø (E)14Ø POC (E)R S1 450 15x15S1450 15x15 (E)S 600 12Ø 14Ø 12Ø (E)14Ø R1 22x22 HALL 114 STORAGE STAIR HALL 139 DF-12 E1150 12x12 E1150 12x12 S1100 6x6 S1100 6x6 3 3 3 3 STAIR 123 TYPICAL VOLUME DAMPER, REFER TO DETAIL 6/MP-002 R1 22x22 R122x22 LAV-1 WC-1 WC-1 LAV-1 1 MECHANICAL & PLUMBING FIRST FLOOR PLAN SCALE:1/8" = 1'-0" KEY NOTES APPLICABLE TO THIS SHEET ONLY CONNECT NEW FIXTURE WITH EXISTING PIPING IN WALL. 1/2" HOT AND COLD WATER, 1-1/2" VENT AND 2" WASTE. CONNECT NEW FIXTURE WITH EXISTING PIPING IN WALL. 1/2" COLD WATER, 1-1/2" VENT AND 2" WASTE. CONNECT (E) DUCT TO NEW GRILLE/DIFFUSER. GENERAL NOTES APPLICABLE TO THIS SHEET ONLY 1 ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE. 2 NEW FLEXIBLE DUCT SHALL NOT EXCEED 60" IN LENGTH. EXTEND EXISTING RIGID DUCT AS NECESSARY TO MAKE THE FLEXIBLE DUCT CONNECTION TO THE DIFFUSER NO MORE THAN 60" LONG. 3 SEE PLUMBING FIXTURE SCHEDULE FOR BRANCH PIPE SIZING. 4 PROVIDE ANGLE STOPS FOR ALL PLUMBING FIXTURE BRANCH PIPING LINES. 5 REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF FIXTURES, INCLUDING BUT NOT LIMITED TO FLOOR SINKS, FLOOR DRAINS, TRENCH DRAINS, ROOF DRAINS, ETC. 6 AFTER COMPLETION OF THE DUCTWORK MODIFICATIONS, BALANCE THE SHOWN AIR DISTRIBUTION TO THE VALUES LISTED. 1 2 3 CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g P l a n . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T ME C H A N I C A L & P L U M B I N G F I R S T F L O O R P L A N MP-200 UP UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 BREAK ROOM 215 SERVER 216 PANTRY 216 CHIEF 214C ADMIN 214A DEPT. CHIEF 213 DEPT. CHIEF 211 COPY ROOM 210 ELEV MECH 112 ELEVATOR 131 CONF. 202 MEETING ROOM 202 PUBLIC AFFAIRS MANAGER 205 BOS. MANAGER 206 BREAK ROOM 207 INT. AFFAIRS LIEUT. 224 MENS 129 JAN 223 WOMENS 222 HALL 149 EQUIP. 220 TRAIN/HIRING MANAGER 208 CRIME ANALYST 209 T S1600 15x15 (E)S250 (E)18Ø (E)14Ø (E)18Ø (E)S100 (E)10Ø (E)6Ø (E)10Ø (E)10Ø (E)14Ø POC 14Ø S1625 15x15 S1 400 15x15 POC POC R1 22x22 R1 22x22 WC-21 STAIRS 144 T 2DS 1 ODU ON ROOF DS 1 IDU ON WALL ABOVE DOOR E1200 12x12 S1 150 9x9 S1200 9x9 E1250 12x12 3 3 3 3 REFRIGERANT PIPING DN FRM ROOF WC-1 LAV-1 WC-1 WC-2 WC-2 LAV-1 LAV-1 DS-1 IMS-1 S-1 1/2"CW DOWN IN WALL 4 UR-1 STAIRS 152 6 POC 1 MECHANICAL & PLUMBING SECOND FLOOR PLAN SCALE:1/8" = 1'-0" KEY NOTES APPLICABLE TO THIS SHEET ONLY CONNECT NEW FIXTURE WITH EXISTING PIPING. 3/4" COLD WATER, 2" VENT AND 3" WASTE. 3/4" CD DN SERVER ROOM WALL. CONNECT TO SINK TAILPIECE PER DETAIL 7/MP-002. CONNECT (E) DUCT TO NEW GRILLE/DIFFUSER. CONNECT 1/2"CW TO (E) CW. PLUMBER TO FIELD VERIFY EXACT LOCATION OF PIPING. 3/4" CONDENSATE CONNECTION TO MECHANICAL EQUIPMENT. SEE DETAIL 8/MP-002 FOR MORE INFORMATION. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. GENERAL NOTES APPLICABLE TO THIS SHEET ONLY 1 ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE. 2 NEW FLEXIBLE DUCT SHALL NOT EXCEED 60" IN LENGTH. EXTEND EXISTING RIGID DUCT AS NECESSARY TO MAKE THE FLEXIBLE DUCT CONNECTION TO THE DIFFUSER NO MORE THAN 60" LONG. 3 SEE PLUMBING FIXTURE SCHEDULE FOR BRANCH PIPE SIZING. 4 PROVIDE ANGLE STOPS FOR ALL PLUMBING FIXTURE BRANCH PIPING LINES. 5 REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF FIXTURES, INCLUDING BUT NOT LIMITED TO FLOOR SINKS, FLOOR DRAINS, TRENCH DRAINS, ROOF DRAINS, ETC. 6 AFTER COMPLETION OF THE DUCTWORK MODIFICATIONS, BALANCE THE SHOWN AIR DISTRIBUTION TO THE VALUES LISTED. 1 2 3 4 5 6 CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION S: \ S h a r e d \ J o b s \ E N G P r o j e c t s \ S L O P D N o r t h B u i l d i n g T I \ E n g i n e e r i n g \ S L O P D N o r t h B u i l d i n g T I M e c h a n i c a l a n d P l u m b i n g P l a n . d w g k h a n j i e v S e p 1 3 , 2 0 2 4 - 9 : 5 7 a m AS INDICATED 05/14/2024 2000577-04 BY 3C Engineering, Inc., ALL COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS RESERVE THIS DOCUMENT AS AN ORIGINAL AND UNPUBLISHED WORK PRODUCT. THIS WORK SHALL NOT BE DUPLICATED, COPIED, DISCLOSED OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF VISUAL CONTACT. THIS DOCUMENT SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. R E G I STE R E D P R O F E S S I ON A L E N G I N E E R B R I A N P.S TA RR E T T S T A TE OF C A L I F O R N I AM ECH A N I C A L EXP. 6/30/26 M 34068 DS KH BS 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T ME C H A N I C A L & P L U M B I N G S E C O N D F L O O R P L A N MP-300 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 1 p m - C h r i s - C : \ U s e r s \ c h r i s \ a p p d a t a \ l o c a l \ t e m p \ A c P u b l i s h _ 2 7 7 0 4 \ 2 4 - 8 0 2 6 _ E - 0 0 1 - E L E C T R I C A L G E N E R A L N O T E S . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT 1.CODE COMPLIANCE: ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH CODES, STANDARDS, AND ORDINANCES AS SET FORTH BY THE AUTHORITIES HAVING JURISDICTION AND THEIR LATEST ADOPTED EDITIONS (IN EFFECT AT TIME OF BUILDING PERMIT APPLICATION) OF THE FOLLOWING PUBLICATIONS: A.ALL WORK SHALL COMPLY WITH 2020 NATIONAL ELECTRICAL CODE (NEC) AS AMENDED BY THE 2022 CALIFORNIA ELECTRICAL CODE (CEC), 2022CALIFORNIA BUILDING CODE (CBC), 2022 CALIFORNIA ENERGY CODE (CEnC), CALIFORNIA FIRE CODE (CFC), 2022 CALIFORNIA MECHANICAL CODE (CMC), 2022 CALIFORNIA GREEN BUILDING STANDARDS (CGBC), AND ADOPTED ORDINANCES. B.AMERICANS WITH DISABILITIES ACT (ADA). 2.SAFETY: THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN A SAFE AND RESPONSIBLE MANNER. KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED. CONDUCT ALL CONSTRUCTION OPERATIONS IN A SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER WORKPERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS, FLAGS, TAPE, ETC. AS REQUIRED FOR SAFETY. THE CONTRACTOR SHALL HOLD ALL PARTIES HARMLESS OF NEGLIGENT SAFETY PRACTICES, WHICH MAY CAUSE INJURY TO OTHERS ON OR NEAR THE JOB SITE. 3.FIRE RATED ASSEMBLIES SHALL MAINTAIN RATINGS AS SPECIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7. CONTRACTOR SHALL PROVIDE AND INSTALL PHYSICAL ENCLOSURE AROUND FIXTURES, PANELS, ETC. AS REQUIRED. ALL ASSEMBLIES TO BE PENETRATED SHALL BE INSTALLED WITH APPLICABLE THROUGH-PENETRATION FIRESTOP SYSTEM AS DETERMINED BY UL CLASSIFICATION. BEFORE CONSTRUCTION, VERIFY AND COMPLY WITH REQUIREMENTS OF LOCAL AUTHORITY HAVING JURISDICTION. 4.MOUNTING HEIGHTS SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: +15" AFF: RECEPTACLES, TELEPHONE, TV & DATA OUTLETS. (MEASURED BOTTOM OF OUTLET BOX) +46" AFF: OUTLET ABOVE COUNTER (MEAUSRED TOP OF OUTLET BOX) +48" AFF: LIGHT SWITCHES. (MEASURED TOP OF OUTLET BOX) +48" AFF: FIRE ALARM MANUAL PULL STATIONS, T-STATS. (MEASURED TOP OF OUTLET BOX) THE LOWER OF +80" AFF TO BOTTOM OF LENS, OR 6" BELOW CEILING: FIRE ALARM VISUALS. ELECTRICAL SWITCHES: CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHT AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. [CBC 11B-308.1.1] ELECTRICAL RECEPTACLE OUTLETS: ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM [CBC 11B-308.1.2] CONTROLS AND OPERATING MECHANISMS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 11B-309. BEFORE ROUGH-IN, VERIFY ALL MOUNTING HEIGHTS AND EXACT LOCATIONS FOR ALL EQUIPMENT ELECTRICAL CONNECTIONS, STUB-UPS, RECEPTACLES, OUTLETS, ETC. WITH ARCHITECT OR OWNER. PLACE DEVICES LOCATED ABOVE COUNTERS, SHELVING, ETC. AND IN BATHROOMS SO AS NOT TO CONFLICT WITH EDGES OF WAINSCOTING, COUNTER SPLASH, SHELVING, ETC. ARCHITECTURAL SHEETS SHALL GOVERN. 5.LABEL PANELS, CABINETS, BACKBOARDS, MAIN DEVICES, SAFETY SWITCHES, CONTACTORS AND OTHER SPECIFICALLY DESIGNATED EQUIPMENT SHOWN ON PLANS. USE ENGRAVED LAMINATED PLASTIC NAMEPLATES ATTACHED BY SCREWS OR RIVETS. FOR FEEDERS, NEATLY AND INDELIBLY LABEL CONDUIT DESTINATIONS ON BOTH VISIBLE ENDS OF CONDUIT RUNS WHERE CONDUITS TERMINATE AT DESIGNATED ENCLOSURES, STRUCTURES OR EQUIPMENT (INCLUDING PULL AND SPLICE BOXES). 5.EQUIPMENT ANCHORAGE NOTE ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED TO MEET THE HORIZONTAL AND VERTICAL FORCES PRESCRIBED IN THE 2022 CBC, SECTIONS 1617A.1.18 THROUGH 1617A.1.26, AND ASCE 7-15 CHAPTERS 13, 26, AND 30 AND 2022 CEC 110.3(B) THE ATTACHMENT OF THE FOLLOWING ITEMS SHALL BE DESIGNED TO RESIST THE FORCES PRESCRIBED ABOVE, BUT NEED NOT BE DETAILED ON THE PLANS PER 2022 CBC SECTION 1616A.1.18: A.FURNITURE(EXCEPT STORAGE CABINETS AS NOTED IN 2022 CBC TABLE 13.5-1) B.TEMPORARY OR MOVABLE EQUIPMENT WITH EXCEPTIONS NOTED IN 2022 CBC SECTION 1616A.1.18 ITEM 2. C.ARCHITECTURAL, MECHANICAL, AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, OR F THAT MEET ALL OF THE CRITERIA LISTED IN 2022 SECTION 1616A.1.18 ITEM 3. D.EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUPPORTED BY VIBRATION ISOLATORS. E.EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL/ELECTRICAL ENGINEER. PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTE PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-16, SECTION 13.3 AS DEFINE IN ASCE 7-16 SECTIONS 13.6.5, 13.6.6, 13.6.7, 13.6.8, AND 2022 CBC, SECTIONS 1617A.1.24, 1617A.1.25, AND 1617A.1.26. 6.THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING THE CORRECTION OF ERROS ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY, RELEVANT LAWS, ORDINANCES, RULES AND/OR REGULATIONS. GENERAL NOTES DEMOLITION FLOOR PLAN A.FUSING: ALL FUSIBLE SAFETY DISCONNECT SWITCHES SHALL BE PROVIDED WITH DUAL-ELEMENT TIME DELAY TYPE FUSES SIZED AND RATED PER EQUIPMENT MANUFACTURERS' RECOMMENDATIONS. VERIFY WITH EQUIPMENT NAMEPLATE BEFORE INSTALLATION. B.INSTALL SEPARATE NEUTRALS FOR EACH 120V BRANCH CIRCUIT. C.MOTOR OVERLOAD PROTECTION: WHERE REQUIRED BY NEC ARTICLE 430 PART C AND NOT SHOWN ON PLAN OR PROVIDED INTEGRAL WITH EQUIPMENT, PROVIDE AND INSTALL THERMAL OVERLOAD PROTECTION FOR ALL MOTORS. D.SPARE CONDUIT FOR RECESSED PANELS: PROVIDE (1) 3/4" SPARE CONDUIT STUB UP TO ACCESSIBLE ABOVE CEILING SPACE AND/OR ACCESSIBLE SPACE BELOW FOR EVERY (3) SPARE BREAKER SPACES AS INDICATED ON PANEL SCHEDULES. E.DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE, ETC. AND SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER EQUIPMENT. F.ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION, SHALL BE MOUNTED ON OPPOSITE SIDES OF THE SAME STUD. COORDINATE BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS. G.ALL NEW OUTLETS MUST BE TAMPER PROOF. H.ALL 15 AND 20AMPERE RECEPTACLES FOR BOTH DAMP AND WET LOCATIONS REQUIRED TO BE LISTED WEATHER-RESISTANT (WR) TYPE PER CEC 406.9 (A) AND (B) I.CEC 406.9(A) RECEPTACLES IN DAMP LOCATIONS: RECEPTACLES INSTALLED OUTDOORS IN A LOCATION PROTECTED FROM THE WEATHER OR IN OTHER DAMP LOCATIONS SHALL BE AN ENCLOSURE FOR THE RECEPTACLE THAT IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT PLUG CAP NOT INSERTED AND RECEPTACLE COVERS CLOSE) J.CEC 406.9(B) RECEPTACLES OF 15 AND 20AMP, 125 AND 250 VOLTS INSTALLED IN A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BE IDENTIFIED AS 'EXTRA-DUTY" OTHER LISTED PRODUCTS, ENCLOSURES, OR ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO NOT UTILIZE AN OUTLET BOX HOOD NEED TO BE MARKED "EXTRA DUTY" EXCEPTION: 15 AND 20AMP, 125 THROUGH 250 VOLT RECEPTACLES INSTALLED IN A WET LOCATION AND SUBJECT TO ROUTINE HIGH-PRESSURE SPRAY WASHING SHALL BE PERMITTED TO HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHEN THE ATTACHMENT PLUG IS REMOVED. A.NIGHT LIGHT "NL" DESIGNATED LUMINAIRES IN INTERIOR LOCATIONS SHALL HAVE ONE BALLAST CONTINUOUSLY ENERGIZED. LUMINAIRES IN EXTERIOR LOCATIONS SHALL BE AUTOMATICALLY CONTROLLED TO BE ON FROM DUSK TO DAWN. B.LIGHTING FIXTURE LOCATIONS SHOWN ARE SCHEMATIC. REFER TO ARCHITECTURAL PLANS (REFLECTED CEILING, ELEVATIONS, ETC.) FOR EXACT LOCATIONS AND MOUNTING HEIGHTS PRIOR TO ROUGH-IN. C.REFER TO ARCHITECT'S REFLECTED CEILING PLAN(S) FOR CEILING HEIGHTS, TYPES, FINISHES, ETC. IN EACH AREA. VERIFY FLANGE TYPES, TRIM KITS, STEM LENGTHS, ETC. FOR ALL FIXTURES PRIOR TO SUBMITTALS. D.CONFIRM LOCATION OF ALL DOORS SWINGS WITH ARCHITECTURAL PLANS PRIOR TO ROUGH-IN OF SWITCHES. E.PROVIDE UNSWITCHED HOT LEG OF ROOM LIGHTING BRANCH CIRCUIT TO EACH BATTERY POWERED EMERGENCY LIGHT AND EXIT SIGN FOR CONTINUOUS CHARGING. LIGHTING FLOOR PLAN RATED WALLS/ASSEMBLIES NOTES SHEET NO.SHEET DESCRIPTION E-001 ELECTRICAL GENERAL NOTES E-002 ELECTRICAL LEGEND AND ABBREVIATIONS E-003 ELECTRICAL SINGLE LINE DIAGRAM AND SCHEDULES ED-101 FIRST FLOOR POWER AND SIGNAL DEMOLITION PLAN ED-102 SECOND FLOOR POWER AND SIGNAL DEMOLITION PLAN E-101 FIRST FLOOR POWER AND SIGNAL PLAN E-102 SECOND FLOOR POWER AND SIGNAL PLAN E-111 FIRST FLOOR LIGHTING PLANS E-112 SECOND FLOOR LIGHTING PLANS E-113 LIGHTING EMERGENCY PHOTOMETRIC PLANS E-121 ELECTRICAL ROOF PLAN E-201 ELECTRICAL DETAILS E-301 TITLE 24 ENERGY FORMS - INTERIOR LIGHTING ELECTRICAL SHEET INDEX POWER FLOOR PLAN 1.IN FIRE-RESISTANCE RATED WALLS, DETAIL THROUGH PENETRATIONS AND MEMBRANE PENETRATION PER CBC 714.4 AS NOTED BELOW: A.STEEL, FERROUS OR COPPER PIPES MAY PENETRATE FIRE-RESISTANCE RATED WALLS, PROVIDED THE OPENING IS PROTECTED AS FOLLOWS: (CBC 714.4.1) i. ITEM PENETRATING CONCRETE OR MASONRY WALLS IS A MAXIMUM 6 INCHES NOMINAL DIAMETER AND THE AREA OF THE OPENING THROUGH THE WALL DOES NOT EXCEED 144 SQUARE INCHES, CONCRETE, GROUT OR MORTAR IS PERMITTED WHERE IT IS INSTALLED THE FULL THICKNESS OF THE WALL OR THE THICKNESS REQUIRED TO MAINTAIN THE F IRE-RESISTANCE RATING; OR ii. WHEN THE ANNULAR SPACE IS PROTECTED WITH MATERIAL THAT MEETS ASTM E 119 OR UL 263. B. PENETRATIONS SHALL BE FIRE-STOPPED BY A SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479, AND SHALL HAVE AN F RATING OF NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL PENETRATED. (CBC 714.4.1.2) C.MEMBRANE PENETRATIONS OF MAXIMUM 2-HOUR FIRE-RESISTANCE RATED WALLS BY STEEL ELECTRICAL BOXES ARE PERMITTED, PROVIDED THAT EACH DOES NOT ESCEED 16 SQUARE INCHES IN AREA AND THE TOTAL AREA OF SUCH OPENING DOES NOT EXCEED 100 SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL AREA, AND THE SPACE BETWEEN THE WALL MEMBRANE AND THE BOX DOES NOT EXCEED 1 8 INCH. ADDITIONALLY, OUTLET BOXES ON OPPOSITE SIDES OF THE WALL SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES (CBC 714.4.2 EXCEPTION 1). D.MEMBRANE PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY MATERIAL ARE PERMITTED, PROVIDED SUCH BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE RATED ASSEMBLIES, AND THE SPACE BETWEEN THE WALL MEMBRANE AND THE BOX DOES NOT EXCEED 1/8 INCH UNLESS LISTED OTHERWISE. ADDITIONALLY, OUTLET BOXES ON OPPOSED SIDES OF THE WALL SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES. (CBC 714.4.2 EXCEPTION 2) E.A FIRE SPRINKLER SHALL BE PERMITTED TO BE UNPROTECTED PROVIDED SUCH SPACE IS COVERED BY A METAL ESCUTCHEON PLATE. (CBC 714.4.2 EXCEPTION 5) F.WHERE WALLS ARE PENETRATED BY OTHER MATERIALS OR OPENINGS LARGER THAN THOSE MENTIONED ABOVE, THEY MUST BE QUALIFIED BY TEST IN ACCORDANCE WITH CBC 714.4.2 EXCEPTION 2. 2.IN FIRE-RESISTANCE HORIZONTAL ASSEMBLIES , DETAIL THROUGH PENETRATIONS AND MEMBRANE PENETRATION PER CBC 714.5 AS NOTED BELOW: A.STEEL, FERROUS OR COPPER CONDUITS MAY PENETRATE FIRE-RESISTANCE RATED FLOOR ASSEMBLY WHEN THE ANNULAR SPACE IS PROTECTED WITH MATERIAL THAT MEETS ASTM E 119 OR UL 263 (CBC 714.5.1 EXCEPTION 1) B.PENETRATING ITEMS, AS NOTED ABOVE, WITH A MAXIMUM 6 INCHES NOMINAL DIAMETER SHALL NOT BE LIMITED TO THE PENETRATION OF A SINGLE FIRE-RESISTANCE RATED FLOOR ASSEMBLY, PROVIDED THAT THE AREA OF THE OPENINGS DOES NOT EXCEED 144 SQUARE INCHES IN ANY 100 SQUARE FEET OF FLOOR AREA. (CBC 714.4.1.1 EXCEPTION 1) C.PENETRATIONS SHALL BE FIRE-STOPPED BY A SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479. THE SYSTEM SHALL HAVE AN F RATING AND T RATING OF NOT LESS THAN 1-HOUR BUT NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE FLOOR PENETRATED (CBC 714.5.1) D.MEMBRANE PENETRATIONS BY LISTED ELECTRICAL OUTLET BOXES ARE PERMITTED PROVIDED SUCH BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE RATED ASSEMBLIES, AND THE SPACE BETWEEN THE CEILING MEMBRANE AND THE BOX DOES NOT EXCEED 1/8 INCHESUNLESS LISTED OTHERWISE. (CBC 714.5.2 EXCEPTION 4) E.A FIRE SPRINKLER SHALL BE PERMITTED TO BE UNPROTECTED PROVIDED SUCH SPACE IS COVERED BY A METAL ESCUTCHEON PLATE. (CBC 714.5.2 EXCEPTION 5) 3.JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE RATED WALL, FLOOR OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED AN APPROVED FIRE-RESISTANT JOINT SYSTEM WITH A FIRE-RESISTANCE RATING NOT LESS THAN THAT OF THE ASSEMBLY IN WHICH IT IS INSTALLED. PROVIDE DETAILS (CBC 7145.1) 4.FIRE DOORS AND FIRE-PROTECTION RATED GLAZING SHALL BEAR LABELS AS REQURIED BY CBC 716.2.9 AND 716.3.5. 5.FIRE DAMPERS SHALL BE THE MINIMUM FIRE PROTECTION RATING SPECIFIED IN CBC TABLE 717.3.2.1 FOR THE TYPE OF PENETRATION (CBC 717.3.2.1) 6.PROVIDE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION DAMPERS SHALL BE PROVIDE AS PRESCRIBED IN CBC 717. REFER TO SPECIFICATIONS 26 0519 FOR ADDITIONAL INFORMATION. 1. WIRE CONNECTORS SHALL BE MINIMUM 75 DEGREE CENTIGRADE RATED AND PROPERLY SIZED FOR THE NUMBER OF CONDUCTORS BEING CONNECTED, TERMINATED, SPLICED, ETC. ALL ABOVE GRADE CONNECTORS SHALL BE SOLDERLESS LUG OR PLASTIC WIRE NUT TYPE, SCREW ON, PRESSURE CABLE TYPE (WIRE UT OR SPRING NUT TYPE) 600 VOLT, 105 DEGREE C, WITH SKIRT TO COVER ALL PORTIONS OF STRIPPED WIRES. CONNECTOR SHALL BE U.L. RATED FOR NUMBER AND SIZE OF CONDUCTORS BEING JOINED TOGETHER AS SPLICED. 2. WIRES AND CABLES FOR LINE VOLTAGE SYSTEM AND CONTROLS. WIRE AND CABLE SHALL BE COPPER, 600 VOLT RATED THROUGH OUT. CONDUCTORS 14AWG OT 10AWG, SOLID OR STRANDED. CONDUCTORS 8 AWG AND LARGER, STRANDED 3. ALL CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE NOTED. MINIMUM SIZE FOR INDIVIDUAL CONDUCTORS SHALL BE #12 AWG UNLESS OTHERWISE NOTED ON PANEL SCHEDULE OR PLANS. SIZE #8 AWG AND LARGER SHALL BE STRANDED CONDUCTOR. INDIVIDUAL CONDUCTORS SHALL BE INSULATED WITH TYPE, XHHW, THW, THHN/THWN 600 VOLT INSULATION UNLESS OTHERWISE NOTED. 4. PROPER INSULATION TYPE SHALL BE USED FOR THE PROPER ENVIRONMENTAL APPLICATION (I.E. WATERPROOF, WET LOCATION, PLENUM TEMPERATURE RATED). ALL CONDUCTORS, WIRING CABLE WHERE INSTALLED BELOW FLOOR, SLAB OR UNDERGROUND SHALL BE CONSIDERED WET LOCATIONS, AND SHALL BE RATED ACCORDINGLY. NON WATERPROOF CABLING IS NOT ALLOWED IN ANY BELOW GRADE OR WET APPLICATION. 5.GROUP THE COMMON NEUTRAL CONDUCTOR FOR MULTIPLE CIRCUITS WITH ITS ASSOCIATED UNGROUNDED CONDUCTORS WHEN CONTAINED IN THE SAME ENCLOSURE. CEC 200.4(B) 6.THE BRANCH CIRCUIT SERVING EMERGENCY LIGHTING AND POWER CIRCUITS SHALL NOT BE PART OF A MULTIWIRE BRANCH CIRCUIT. CEC 700.19. CONDUCTORS AND CABLES COMMUNICATIONS PLAN NOTES A.PROVIDE SEALTITE POWER & CONTROL CONNECTIONS TO ALL AC UNITS. B.ALL EQUIPMENT SHOWN ABOVE ROOF IS NEMA 3R. C.VERIFY EXACT EQUIPMENT LOCATIONS AND POINTS OF CONNECTION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. D.CONDUIT SHOWN IS ROUTED IN CEILING SPACE BELOW ROOF DECK. E.NO ROOF MOUNT CONDUIT IS ALLOWED UNLESS OTHERWISE NOTED. F.FUSE DISCONNECT SWITCHES PER EQUIPMENT NAMEPLATE RATING. G.ALL ROOF PENETRATIONS SHALL BE MADE WITH ROOF JACKS, SEAL ALL PENETRATIONS WITH MASTIC. ROOF PLAN NOTES A. REFER TO ARCHITECTURAL DEMOLITION SHEETS FOR ADDITIONAL INFORMATION. B. EQUIPMENT SHOWN TO BE REMOVED IS SHOWN FOR REFERENCE ONLY. INFORMATION WAS OBTAINED FROM ORIGINAL BUILDING DRAWINGS AND LIMITED FIELD INVESTIGATION AND MAY NOT REPRESENT ALL ELECTRICAL DEMOLITION. FIELD VERIFY CONDITIONS AND DISCONNECT/REMOVE ALL EQUIPMENT AS REQUIRED TO MEET THE INTENT OF THAT SHOWN ON THE LIGHTING AND POWER/SIGNAL DRAWINGS. C. ALL ELECTRICAL EQUIPMENT SHOWN ON DRAWING (OR REQUIRED) TO BE DEMOLISHED SHALL BE DISCONNECTED, REMOVED AND DISPOSED OF BY ELECTRICAL CONTRACTOR. NO EQUIPMENT (RACEWAYS, BOXES, CABLING, ETC.) SHALL BE ABANDONED IN PLACE AND COVERED BY NEW CONSTRUCTION. D. CLEAN, REPAIR (AS REQUIRED) AND RELAMP ALL EXISTING LIGHT FIXTURES THAT ARE TO REMAIN AND BE RE-USED TO ASSUME ALL FIXTURE ARE OPERATIONAL UPON COMPLETION OF PROJECT. E. ANY LIGHT SWITCHES THAT ARE NO LONGER IN USE, WHETHER SHOWN ON THE DEMOLITION PLAN OR NOT, ARE TO HAVE THE DEVICE AND WIRING REMOVED, AND A BLANK COVER PLATE INSTALLED. F. SCHEDULE ANY OUTAGES WITH OWNER PRIOR TO DE-ENERGIZATION OF ANY BRANCH CIRCUITS OR FEEDERS. G. DISCONNECTION/REMOVAL OF EXISTING COMMUNICATIONS SYSTEMS COMPONENTS SHALL BE SCHEDULED WITH CITY OF SAN LUIS OBISPO. H. SALVAGE ALL REMOVED COMPONENTS (SPEAKERS, GRILLES, TELEPHONE INSTRUMENTS, RADIO HANDSETS, ETC.) SHALL BE SALVAGED TO THE OWNER. I. INFORMATION SHOWN FOR LOAD DESCRIPTIONS ON EXISTING PANELS WAS GAINED FROM ORIGINAL BUILDING ELECTRICAL PLANS AND SHALL BE FIELD VERIFIED. CONFIRM LOAD ON EACH CIRCUIT OF ALL EXISTING PANELS AND PROVIDE UPDATED TYPEWRITTEN CIRCUIT DIRECTORY (IN PLASTIC SLEEVE) FOR EACH EXISTING PANELBOARD. J. ANY LOADS REMOVED DURING DEMOLITION SHALL HAVE CONDUCTORS REMOVED BACK TO NEXT REMAINING DEVICE OR TO EXISTING PANELS. ABANDONED BREAKERS SHALL BE LABELED "SPARE". K. PROVIDE BLANK FILLER PLATES IN DEADFRONTS OF EXISTING PANELBOARDS UPON COMPLETION OF PROJECT WHERE BREAKERS HAVE BEEN REMOVED. A.ALL 15 AND 20AMPERE RECEPTACLES FOR BOTH DAMP AND WET LOCATIONS REQUIRED TO BE LISTED WEATHER-RESISTANT (WR) TYPE PER CEC 406.9 (A) AND (B) B.CEC 406.9(A) RECEPTACLES IN DAMP LOCATIONS: RECEPTACLES INSTALLED OUTDOORS IN A LOCATION PROTECTED FROM THE WEATHER OR IN OTHER DAMP LOCATIONS SHALL BE AN ENCLOSURE FOR THE RECEPTACLE THAT IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT PLUG CAP NOT INSERTED AND RECEPTACLE COVERS CLOSE) C.CEC 406.9(B) RECEPTACLES OF 15 AND 20AMP, 125 AND 250 VOLTS INSTALLED IN A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BE IDENTIFIED AS 'EXTRA-DUTY" OTHER LISTED PRODUCTS, ENCLOSURES, OR ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO NOT UTILIZE AN OUTLET BOX HOOD NEED TO BE MARKED "EXTRA DUTY" EXCEPTION: 15 AND 20AMP, 125 THROUGH 250 VOLT RECEPTACLES INSTALLED IN A WET LOCATION AND SUBJECT TO ROUTINE HIGH-PRESSURE SPRAY WASHING SHALL BE PERMITTED TO HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHEN THE ATTACHMENT PLUG IS REMOVED. RECEPTACLES AT DAMP AND WET LOCATION EL E C T R I C A L G E N E R A L N O T E S E-001 A.DATA AND TV RACEWAYS AND BOXES: a.PROVIDE AND INSTALL 4" SQUARE RECESSED JUNCTION BOX WITH 1-GANG RING. RUN 3/4" EMT CONDUIT STUB TO ACCESSIBLE CEILING SPACE ABOVE FLOOR DATA MAX 3-CAT6A CABLES. b.PROVIDE AND INSTALL 5" SQUARE RECESSED JUNCTION BOX WITH 1-GANG RING. RUN 1-1/4" EMT CONDUIT STUB TO ACCESSIBLE CEILING SPACE ABOVE FLOOR DATA MAX 10-CAT6A CABLES. BEFORE CONSTRUCTION, COORDINATE AND VERIFY ALL DATA AND TELEPHONE LOCATIONS WITH OWNER OR ARCHITECT. B.ALL NEW HORIZONTAL CABLES, RISER RATED (CMR) CABLES SHALL BE CAT6A (BERK-TEK #LANMARK-10G2 - BLUE) C.DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE, ETC. AND SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER EQUIPMENT. D.ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION, SHALL BE MOUNTED ON OPPOSITE SIDES OF THE SAME STUD. COORDINATE BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS. E.CAT6A CABLES, TOTAL LENGTH FROM IDF TO ENDPOINT SHALL NOT BE MORE THAN 295'-0", EC SHALL BRING TO THE ATTENTION OF THE ENGINEER ANY LENGTHS IN EXCESS OF 295'-0". F.ALL COMMUNICATION WORK SHALL COMPLY WITH CITY OF SAN LUIS OBISPO STANDARDS. OBTAIN COMPLETE LIST OF STANDARDS, AND ADHERE ACCORDINGLY. G.TEST ALL NEW AND EXISTING RE-USE CABLES. CONDUIT SYSTEMS NOTES CONDUIT SYSTEMS USED ON THIS PROJECT SHALL BE AS FOLLOWS 1. PVC SCHEDULE 40 - underground/below slab with GRS elbows and risers tape wrapped). 2.ELECTRICAL METALLIC CONDUIT (EMT) - above grade/slab in building construction and where exposed above 8'-0" aff. 3.GALVANIZED RIGID STEEL (GRS) - where exposed below 8'-0" aff. and/or where subject to physical damage. 4.FLEXIBLE STEEL CONDUIT - above ceilings and/or concealed in building construction (seal tight flex required in exterior locations). 6.MC CABLE NOT ALLOWED. REFER TO SECTION 260533 & 260500 OF SPECIFICATIONS FOR ADDITIONAL INFORMATION. CONDUITS SHALL BE MINIMUM 3/4" UNLESS OTHERWISE NOTED. CONDUIT SIZES, WHERE NOT NOTED ON THE DRAWINGS, SHALL BE SIZED FOR MAXIMUM 40% FILL PER CEC 310-6. ADDITIONAL CONDUIT REQUIREMENTS. -ROUTE CONDUIT(S) BELOW GRADE OR ABOVE CEILING SO THAT WALL OUTLETS, DEVICES, AND CONDUITS IN ALL EXPOSED BRICK WALL LOCATIONS SHALL BE RECESSED MOUNTED INSIDE BRICK. LOCATE DEVICES AT CELL WITH REINFORCEMENT CENTER AT BRICK AND/OR ONE CELL OVER AWAY FROM JAMB. REFER TO ARCHITECTURAL AND STRUCTURAL PLANS FOR CMU WALL LOCATIONS SECTIONS, AND DETAILS. - REFER TO ELECTRICAL DETAILS FOR METAL PIPE PENETRATION THRU FIRE RATED WALL. PENETRATION OF FIRE-RESISTIVE WALLS AND FLOOR CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SECTION 714. - REFER TO ELECTRICAL DETAIL FOR DEVICE INSTALLATION FOR FIRE RATED WALLS. -NO CONDUITS OR PIPING IN ANY SPACE SHALL BE EXPOSED AT THE CEILING AND WALL (COORDINATE WITH ALL DISCIPLINES PRIOR TO CONSTRUCTION). LOCATE ALL CONDUIT WITHIN WALLS ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 1 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 0 0 2 - E L E C T R I C A L L E G E N D & A B B R E V I A T I O N S . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT POWER LEGEND NOTE: INTERPRET IN CONTEXT MISCELLANEOUS CONDUIT/WIRE LIGHT FIXTURES CONVENTIONS LEGEND 3103 NUMBERED SHEET NOTES: REFERS TO NOTES ON SAME SHEET AS REFERENCE DETAIL REFERENCE: Z = DETAIL DESIGNATION X = SHEET NUMBER REFERENCE Z X FEEDER SCHEDULE DESIGNATION (EXAMPLE: 3103 = 310 AMPERE, 600V, 3 CURRENT CARRYING CONDUCTORS, PREFIXES: 'M' INDICATES MEDIUM VOLTAGE, 'CO14' INDICATES CONDUIT ONLY, QUANTITY (1) AND SIZE (4")) X MECHANICAL SYSTEMS TAG (REFER TO MECHANICAL SHEETS) Y = UNIT TYPE X = UNIT NUMBER Y X COMBINATION STARTER MAGNETIC CONTACTOR DAMPER MOTOR HUMIDISTAT SURFACEMOUNT CABINET FLUSHMOUNT CABINET SURFACEMOUNT PANEL FLUSHMOUNT PANEL PUSHBUTTON H M DM SPEAKER- WALLMOUNT SPEAKER- CLG FLUSHMOUNT HEADSET OUTLET AUXILIARY INPUT MICROPHONE INPUT CLOCK/SPEAKER WALLMOUNT SPEAKER- CLG FLUSHMOUNT VANDAL-RESISTANT VOLUME CONTROL V S SEMI-FLUSH S A HS V M S S CIRCUIT BREAKER FUSIBLE SWITCH GROUND THERMOSTAT SURFACE A LETTER ADJACENT INDICATES (ARROW INDICATES DIRECTION) FIXTURE TYPE RECESSED WALL MOUNT EXIT LIGHT- CEILING EXIT LIGHT- WALL WALL-PACK CLOCK PHASEØ T MOTOR UPLIGHT- FLUSH IN GRADE POLE LIGHT- DECORATIVE PENDANT LINEAR UNDERCABINET LIGHT TANDEM-WIRED LAMPS BOLLARD STRIP UON DIRECTIONAL FLOOD EMERGENCY FIXTURE POLE LIGHT TRACK LIGHT CEILING SURFACEMOUNT WALL SURFACEMOUNT RECESSED DOWNLIGHT RECESSED WALLWASH RECESSED PENDANT MOUNT (E) POWER HOMERUN INDICATES LINE CONTINUES WIRE LINE- CONTINUES CONDUIT STUB (W/MARKER) VERTICAL CONDUIT RUN FLEXIBLE CONNECTION SURFACEMOUNT RACEWAY CORD W/PLUG LOW VOLTAGELV CONDUIT SEAL NEW POWER HOMERUN (3 HOTS & NEUT SHOWN) ISOLATED GROUND EXISTING TO REMAIN NEW E UNDERGROUND WALL MOUNTED CLOCK CLOCK/SPEAKER COMBINATION S SAFETY DISCONNECT SOUND END OF LINE RESISTOR DUCT SMOKE DETECTOR VISUAL- VISUAL DEVICE MANUAL PULL STATION HORN- AUDIBLE DEVICE AUDIBLE/VISUAL SMOKE DETECTOR HEAT DETECTOR BELL TAMPER SWITCHT P FLOW SWITCH AV V F H FIRE ALARM CONTROL PANEL REMOTE POWER SUPPLYRPS SPEAKER/VISUALSV FIRE ALARM SFD SMOKE FIRE DAMPER SDCO SD D SD H B SMOKE DETECTOR WITH CO WALL SURFACE MOUNT LINEAR TYPE LED COVE & UNDERCABINET LIGHT PER FIXTURE SCHEDULE J JUNCTION BOX SDV SMOKE DETECTOR WITH VISUAL A AMPERE AB AMP BREAKER ABAND ABANDONED ABV ABOVE AC ALTERNATING CURRENT AC-#AIR CONDITIONER ADJ ADJACENT AF AMP FUSE, AMP FRAME AFF ABOVE FINISH FLOOR AFG BOVE FINISH GRADE AIC AMPERES INTERRUPTING CAPACITY Al ALUMINUM AS AMP SWITCH RATING ATS AUTOMATIC TIME SWITCH ATS AUTOMATIC TRANSFER SWITCH AV AUDIBLE/AUDIO VISUAL AWG AMERICAN WIRE GAGE BFG BELOW FINISH GRADE BIL BASIC IMPULSE LEVEL BLDG BUILDING C CONDUIT -C-CATV CONDUIT CAB'T CABINET CATV CABLE TELEVISION CB CIRCUIT BREAKER, CODE BLUE CBC CA. BUILDING CODE CEC CA. ELECTRICAL CODE CA. ENERGY COMMISSION CF COMPACT FLUORESCENT CFC CALIFORNIA FIRE CODE CLG CEILING CL CENTER LINE CKT CIRCUIT CNT'R CONTRACTOR C.O.CONDUIT ONLY (W/PULLROPE) COND CONDUIT, CONDUCTOR CR CRITICAL BRANCH CSFM CALIFORNIA SFM CT CURRENT TRANSFORMER Cu COPPER CU-#CONDENSING UNIT D DEPTH DC DIRECT CURRENT DF DRINKING FOUNTAIN DIA DIAMETER DISC DISCONNECT DIST DISTRIBUTION DPST DOUBLE POLE SINGLE THROW DW DISHWASHER EM EMERGENCY (E)EXISTING EA EACH EB ELECTRONIC BALLAST EC ELECTRICAL CONTRACTOR EC-#EVAPORATIVE COOLER EF-#EXHAUST FAN EL EVENING LIGHT ELEC ELECTRICAL EM EMERG BATTERY BACKUP EMERGENCY BALLAST EMERG EMERGENCY EOL END OF LINE EQUIP'T EQUIPMENT ES ENERGY SAVING (EXN)(E) IN (N) LOCATION (EXR)(E) TO BE (R) EXT EXTERIOR F FLUORESCENT (F)FUTURE F-#FURNACE FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FAT FIRE ALARM TERMINAL FAU FORCED AIR UNIT FBO FURNISHED BY OTHERS FC-# FAN COIL FLA FULL LOAD AMPS FLR FLOOR FLUOR FLUORESCENT FS FUSIBLE SWITCH FVNR FULL VOLTAGE NON-REVERSING G GROUNDING CONDUCTOR GC GENERAL CONTRACTOR GD GARBAGE DISPOSAL GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND GRS GALVANIZED RIGID STEEL GWS GANG WITH SWITCH H HEIGHT, HIGH HACR HEATING, AC & REFRIG HID HIGH INTENSITY DISCHARGE HO HIGH OUTPUT HOA HAND-OFF-AUTO hp HORSEPOWER HPF HIGH POWER FACTOR HPS HIGH PRESSURE SODIUM IC INTERCOM ID IDENTIFICATION IDF INTERMEDIATE DISTRIBUTION FRAME IF INSIDE FROST IG ISOLATED GROUND J-BOX JUNCTION BOX k QUANTITY 1000 kVA KILOVOLTAMPS kW KILOWATT LC LIGHTING CONTACTOR LPS LOW PRESSURE SODIUM LRA LOCKED ROTOR AMPS LS LIFE SAFETY BRANCH LT LIGHT LTG LIGHTING LV LOW VOLTAGE MC MECHANICAL CONTRACTOR MCA MINIMUM CKT AMPS MCB MAIN CIRCUIT BREAKER MCTB MAIN CATV TERMINAL BOARD MCTC MAIN CATV TERMINAL CABINET MDF MAIN DISTRIBUTION FRAME MECH MECHANICAL MFR MANUFACTURER MFS MAIN FUSIBLE SWITCH MH METAL HALIDE MLO MAIN LUGS ONLY MOCP MAXIMUM OCP MPOE MINIMUM POINT OF ENTRY MSB MAIN SWITCHBOARD MT MOUNT MT HT MOUNTING HEIGHT MTS MANUAL TRANSFER SWITCH MTTB MAIN TELEPHONE TERMINAL BOARD MTTC MAIN TELEPHONE TERMINAL CABINET MW MICROWAVE N NEUTRAL (GROUNDED CONDUCTOR) (N)NEW N3R NEMA 3R NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NAT'L ELEC MANUFACTURER'S ASSOC NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NPF NORMAL POWER FACTOR NTS NOT TO SCALE OC ON CENTER OCP OVERCURRENT PROTECTION OD OUTSIDE DIAMETER OH OVERHEAD OSA OFFICE of the STATE ARCHITECT OSHPD OFFICE of STATEWIDE HEALTH PLANNING & DEVELOPMENT OVLD OVERLOAD P POLE PA PUBLIC ADDRESS PB PULLBOX PC PULL CHAIN PC PHOTOCELL PC PLUMBING CONTRACTOR ph PHASE PNL PANEL POC POINT OF CONNECTION -PP-POWER PRIMARY -PS-POWER SECONDARY PV PHOTOVOLTAIC (R)RELOCATE(D) RECEPT RECEPTACLE REF REFRIGERATOR REQ'D REQUIRED RLA RATED LOAD AMPS RM ROOM RMC RIGID METAL CONDUIT RMV REMOVE RPLC REPLACE RS RAPID START SC SIGNAL CABINET SCC SHORT CKT CURRENT SFM STATE FIRE MARSHAL SHT SHEET SL SLIMLINE, SWITCH LEG SPEC SPECIFICATION SPST SINGLE POLE SINGLE THROW SQ SQUARE STR'G STORAGE SURF SURFACE SVC SERVICE SW SWITCH T TRANSFORMER, TERMINAL -T-TELEPHONE CONDUIT (TBR)TO BE REMOVED TC TIME CLOCK TEL TELEPHONE TELCO TELEPHONE COMPANY TS TIME SWITCH TSO TIME SWITCH OVERRIDE TSP TWISTED SHIELDED PAIR TTB TELEPHONE TERMINAL BOARD TTC TELEPHONE TERMINAL CABINET TX TRANSFORMER TYP TYPICAL TYP SIM TYPICAL SIMILAR UC UNDERCABINET, UNDERCOUNTER UG UNDERGROUND UGPS UNDERGROUND PULL SECTION UL UNDERWRITERS LABORATORIES UON UNLESS OTHERWISE NOTED USA UG SVC ALERT 800-642-2444 V VOLT VA VOLT AMPERES VAC VOLT ALTERNATING CURRENT VHO VERY HIGH OUTPUT VOLT VOLTAGE VR VANDAL-RESISTANT W WIDTH, WATT, WIRE WH-#WATER HEATER WP WEATHERPROOF (NEMA 3R) XFMR TRANSFORMER +48 INDICATES MOUNTING HEIGHT AFF FIXTURE TYPE LIGHTING PLAN B-1,a CIRCUIT NUMBER A POWER PLAN - PROVIDE ALL BRANCH CIRCUIT WIRING FROM DEVICES TO PANEL(S) PER DESIGNATIONS/CIRCUIT NUMBERS. - EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AS INDICATED ON PANEL SCHEDULES. - HOME RUN CONDUITS SHALL BE 3/4"C, MAX OF (3) BRANCH CIRCUITS PER CONDUIT. -INCREASE HOME RUN CONDUIT SIZE TO 1"C FOR (4) BRANCH CIRCUITS OR MORE. -(**) DENOTES SPECIAL DEVICE/NAMEPLATE REQUIREMENTS. - PROVIDE ALL BRANCH CIRCUIT WIRING FROM FIXTURES TO PANEL(S) AS DESCRIBED BY CIRCUIT NUMBERS SHOWN. - PROVIDE ALL WIRING BETWEEN FIXTURES AND CONTROL DEVICES AS DESCRIBED IN REFERENCE NOTES AND/OR SHOWN BY SWITCHLEG DESIGNATIONS. - EXIT AND EMERGENCY LIGHT FIXTURES SHALL BE CONNECTED TO AN UNSWITCHED BRANCH CIRCUIT CONDUCTOR. - HOME RUN CONDUITS SHALL BE 3/4"C., MAX OF (3) BRANCH CIRCUITS PER CONDUIT. - PROVIDE ALL BRANCH CIRCUIT WIRING FROM MECH. EQUIPMENT TO PANELS. SWITCHLEG DESIGNATION (WHERE SHOWN) DEVICE TYPE: SEE LEGEND MOUNTING HEIGHT: (WHERE NON-STANDARD) W - 48" ABOVE FINISHED FLOOR M - ABOVE COUNTER TOP (COORDINATION REQUIRED) TV - MOUNT AT TV HEIGHT (COORDINATION REQUIRED) CLG - CEILING MOUNT SPECIAL CONFIGURATION: WP - **WEATHER PROOF, PROVIDE WHILE IN USE COVER GFI - **GROUND FAULT CIRCUIT INTERRUPTED IG - ISOLATION GROUND GWS - GANG WITH SWITCH CONTROLLED RECEPTACLE: (IF APPLICABLE) SEE LIGHTING CONTROL DETAIL FOR ADDITIONAL INFORMATION CIRCUIT NUMBER: BRACKETS ('[]') DENOTE EXISTING CIRCUIT. PANEL DESIGNATION NOTE:THE INTENT OF THE DRAWINGS IS TO SHOW FIXTURE / DEVICE LOCATIONS AND PANEL DESIGNATIONS. ALL BRANCH CIRCUIT WIRING, MEETING THE CRITERIA NOTED ABOVE, WILL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. LIGHTING AND POWER PLANS SHOW AN ABOVE CEILING JUNCTION BOX / HOME RUN WITH CIRCUIT NUMBERS BY FIXTURES / DEVICES. PROVIDE ALL BRANCH CIRCUITING AS REQUIRED FOR A COMPLETE INSTALLATION. DOCUMENT ALL BRANCH CIRCUITING ON AS-BUILT DRAWINGS ACCURATELY REFLECTING THE INSTALLATION. CIRCUITING LEGEND ABBREVIATIONS 20A DUPLEX RECEPTACLE 20A (GFCI) GROUND FAULT CURRENT INTERRUPTER DEVICE 20A MOUNT ABOVE COUNTER PER ADA. MOUNT AT +48" MEASURED TO TOP OF BOX. WHILE-IN USE NEMA 3R COVER (TAYMAC #MX4280S OR ENGINEER APROVED EQUAL UNLESS OTHERWISE NOTED) FLOOR MOUNTED OUTLET GROUND BAR 20A CEILING MOUNTED OUTLET GANG WITH SWITCH DISCONNECT FUSE OR NON FUSED 20 DOUBLE DUPLEX RECEPTACLE TELEVISION OUTLET. VERIFY MOUNTING HEIGHT PRIOR TO ROUGH-IN. COMBINATION POWER/DATA FLOOR BOX. 20A SINGLE RECEPTACLE 20A DUPLEX- HALF SWITCHED 20A SWITCHED RECEPTACLE J DROP CORD RECEPTACLE 208V 1Ø RECEPTACLE 20AMP DUPLEX OUTLET WITH TYPE A AND TYPE C USB CHARGER SDS SMOKE DETECTOR WITH SOUND NOTE: "C" NEXT TO NOTIFICATION DEVICE ON PLANS DENOTES MOUNT AT CEILING J SF SF WALL MOUNTED SYSTEM FURNITURE COMMUNICATION CONNECTION. EL E C T R I C A L L E G E N D A N D A B B R E V I A T I O N S E-002 COMMUNICATION LEGEND TELE POWER POLE NEW FLUSH MOUNTED DATA OUTLET SHOWN. X DENOTES TOTAL CAT6A CABLES AND PORT FACEPLATE TV MOUNT DATA OUTLET AT TV HEIGHT. PROVIDE 1-CAT6A CABLE. WALL MOUNTED SYSTEM FURNITURE POWER CONNECTION. # CAM AP SECURITY CAMERA WIRELESS ACCESS POINT ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 1 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 0 0 3 - E L E C T R I C A L S I N G L E L I N E D I A G R A M A N D S C H E D U L E S . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT 1 (E) "MSB" SINGLE LINE DIAGRAM (E) "MSB" M PRIMARY SECONDARY 800A BUS, 120/208V, 3 PHASE 4 WIRE (E) PANEL A PANEL B PANEL C (E)PRIM (E)SEC (E)TRANSFORMER T-578 (E) 150A 3P EXISTING EXISTING EXISTING PANEL D EXISTING AC-1 AC-2 ELEVATOR EL E C T R I C A L S I N G L E L I N E E-003 A.ILLUSTRATIONS AND/OR DIMENSIONS ARE APPROXIMATIONS ONLY INTENDED TO REPRESENT BASIC FIXTURE TYPE; DO NOT USE AS EXACT INFORMATION SOURCE. REFER TO MANUFACTURER CUT SHEETS. B.EXACT LOCATIONS: BEFORE CONSTRUCTION, VERIFY WITH ARCHITECT EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL LIGHT FIXTURES. SEE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS AS APPLICABLE. C.FIXTURE BRANCH CIRCUIT THROUGH-WIRING: VERIFY AND COMPLY WITH FIXTURE MANUFACTURER RESTRICTIONS AS DETERMINED BY UL. & NEC. D.VERIFY CEILING TYPES/FINISHES FOR ALL RECESSED FIXTURES PRIOR TO FORWARDING SUBMITTALS. E.ALL RECESSED LUMINAIRES IN CEILINGS SHALL BE LISTED TYPE IC. (E) 150A 3P (E) 150A 3P (E) 100A 3P (E) 40A 3P SPARE (E) 200A 3P (E) 200A 3P (E) 150A 3P (E) 800A 3P, MAIN (E) 80A 2P LEVEL 2 EV CHARGER REFERENCE NOTES 1.EXISTING PANELBOARDS. SEE POWER / SIGNAL FLOOR PLANS FOR LOCATION. INFORMATION LOAD DESCRIPTIONS ON EXISTING PANELS WAS GAINED FROM ORIGINAL BUILDING ELECTRICAL PLANS AND SHALL BE FIELD VERIFIED. CONFIRM LOAD ON EACH CIRCUIT OF ALL EXISTING PANELS PROVIDE UPDATED TYPEWRITTEN CIRCUIT DIRECTORY (IN PLASTIC SLEEVE) FOR EACH EXISTING PANELBOARD. 2.DESIGN IN SITE SCOPE SEPARATE PERMIT. A.ALL CONDUCTORS SHALL BE COPPER WITH TYPE [THHN/THWN] INSULATION UNLESS OTHERWISE NOTED. B.ALL SWITCHES, CIRCUIT BREAKERS AND OTHER EQUIPMENT, AS SPECIFIED, SHALL HAVE TERMINATION PROVISIONS LISTED AND IDENTIFIED FOR USE WITH 75 DEG. CONDUCTORS, AND ALL FEEDER CONDUCTORS, AND CONDUITS, ARE SIZE BASED ON USE OF 75 DEG. C COPPER WIRES TYPE THWN/THHN. C.ALL EQUIPMENT SHALL HAVE AN APPROVED TESTING LABORATORY LABEL ATTACHED [UL, CSA, ETC.] (CEC 110-2). SINGLE LINE DIAGRAM NOTES FIXTURE SCHEDULE NOTES LIGHTING 2 "MSB" LOAD CALCULATIONS INTERIOR LIGHTING FIXTURE SCHEDULE MAX. VA.CATALOG NO.MANUFACTURERILLUSTRATIONTYPE LAMPING MOUNTING DESCRIPTIONVOLTAGE D1 LITHONIA LDN4 40/10 LO4 AR LD TRW MVOLT EZ1 MVOLT 11 LED 4000K RECESSED 4" RECESSED LED DOWNLIGHT. W1 LITHONIA FMVCCLS 24IN MVOLT BN MVOLT 18.12 LED 4000K WALL ABOVE MIRROR 2' CONTEMPORARY CYLINDER VANITY W2 LITHONIA MVOLT 34.86 LED 4000K 1 1 1 1 EXIT SIGN AND EMERGENCY LIGHTING FIXTURE SCHEDULE MAX. VA.CATALOG NO.MANUFACTURERILLUSTRATIONTYPE LAMPING MOUNTING DESCRIPTIONVOLTAGE X1 ISOLITE EDC-EM-R-1-XX-XX -MTEBP MVOLT 5 LED UNIVERSAL UNIVERSAL MOUNT LED EXIT SIGN WITH UNIVERSAL FIELD SELECTABLE CHEVRONS AND EMERGENCY BATTERY BACKUP. X2 ISOLITE CMB-EM-R-U-XX -MTEBP-L1 MVOLT 8 LED UNIVERSAL XM ISOLITE BUG-3W-WH-MB MVOLT 6 LED SURFACE XM E ISOLITE OWL-EM-XX-MB MVOLT 17 LED WALL UNIVERSAL MOUNT LED EXIT SIGN AND EMERGENCY LIGHT COMBO WITH UNIVERSAL FIELD SELECTABLE CHEVRONS AND EMERGENCY BATTERY BACKUP. LED EMERGENCY LIGHT. EXTERIOR LED EMERGENCY LIGHT. FMVCCLS 48IN MVOLT BN WALL ABOVE MIRROR 4' CONTEMPORARY CYLINDER VANITY (SITE PROJECT) 2 1 ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 J "B" JJ J J J J J J J J J JJJJJJ V J JJ J J J J J (TBR) (TBR)(TBR) (TBR) 7 E-201 10 E-201 30A, 120/250V, 1Ø 1 ED-101 EXISTING TELEPHONE BACKBOARD AND MAIN POINT OF ENTRY "A" "MSB" "FACP" S S (E)SAFE B-16 B-16 B-16 B-16 B-16 B-16 B-22 B-22 B-3,26 B-3 B-3 B-26 B-26 B-3 B-3 B-3 B-3,26 B-3 B-3,26 B-2 B-2 B-2 B-19 B-2 B-19 B-2 B-2 B-6,15 B-9,10,12 J B-4,6,17 B-10,11 A-4 A-4B-8B-13,14B-13,14 A-4 B-22 A-2 0 A-20 A-20 A-20 A-20B-28 B-28 A-20 A-1 8 B-2 B-2 A-9 A-9A-24 A-9 A-9 A-4 A-16 A-15 A-13 A-13 A-13 A-17 A-13 A-13 A-16 A-9 A-9 A-16 A-16 A-36 A-36A-36 A-15 A-15 A-16 JJ SHARED OFFICE BUREAU SERGEANT 107 DETECTIVE EQUIPMENT 106 DRONE/EQUIP. STORAGE 105 STAIR MEN 118 WOMEN 119 HALL 115 JAN. ELECTRICAL 120 CIRCULATION 130 BRIEFING ROOM '122 MEETING 125 OFFICE 124 ELEV. STAIR LOBBY 100 STORAGE 111 OPEN OFFICE BREAK ROOM OFFICE HALL 2 2 2 (TBR) 2 (TBR) 2 3 4 4 +84" 6 42 24222 2 2 4 6 6 4 2 2 (TBR) (TBR) (TBR) 1 2 (TBR) 2 3 3 4 17 5 6 7 8 9 (EXR) 10 J San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 1 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E D - 1 0 1 - 1 S T F L R P W R & S I G D E M O P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT NORTH SCALE: POWER / SIGNAL DEMOLITION FIRST FLOOR PLAN 3/16"=1'-0" PO W E R / S I G N A L D E M O L I T I O N F I R S T F L O O R P L A N ED-101 NOTE: ALL DEVICES SHOWN ON THIS PAGE ARE EXISTING UNLESS OTHERWISE NOTED) 1 EXISTING DATA RACK AT ELECTRICAL ROOM REFERENCE NOTES 1.REMOVE AND DISCONNECT OUTLET. 2.REMOVE AND DISCONNECT DATA WIRING FROM EXISTING DATA RACK. 3.REMOVE AND DISCONECT EXISTING OUTLET AT DEMO WALL. RE-USE EXISTING BRANCH CIRCUITS AT NEW OUTLETS. 4.EXISTING FLOOR BOX SHOWN ON AS-BUILT. FIELD VERIFY EXACT LOCATION UNDER CARPET. VERIFY EXISTING BRANCH CIRCUIT AND LABEL. 5.DISCONNECT/REMOVE EXISTING JUNCTION BOX AT FLOOR. CAP EXISTING CONDUIT. 6.EXISTING (17)CAT6 CABLES AT FLOOR. RE-USE (4)CAT6 FOR OUTLETS AT NEW WALL. TONE EXISTING CABLES NOT USED AND DISCONNECT CABLES AT EXISTING DATA RACK. PULL EXISTING CABLES FROM CEILING SPACE. COORDINATE WITH CITY IT FOR ADDITIONAL REQUIREMENTS PRIOR TO DEMO. CAP EXISTING CONDUITS. 7.RE-USE EXISTING BRANCH CIRCUIT TO POWER NEW OUTLETS AT NEW WALL. INTERCEPT EXISTING BRANCH CIRCUIT ABOVE T-BAR CEILING AND EXTEND NEW BRANCH CIRCUIT TO NEW OUTLETS. 8.EXISTING 6-DATA TO BE RELOCATED TO SOUTH WALL. 9.REMOVE EXISTING DOUBLE DUPLEX. RE-USE EXISTING BRANCH CIRCUITS FOR NEW SYSTEM FURNITURE. INTERCEPT EXISTING BRANCH CIRCUITS ABOVE-TBAR CEILING AND EXTEND NEW BRANCH CIRCUIT. 10.EXISTING FLOOR MOUNTED DATA RACK. PROVIDE AND INSTALL (2)48 CAT6A PORT AT EXISTING DATA RACK. HOMERUN ALL NEW FIRST FLOOR CAT6A CABLES TO THIS RACK. X ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 W "D" J J J J J H H V J W M M J J M J J J HD M I J 6 VI D E O S J J J J H 8 E-201 9 E-201 V V J V V V V P M (E)SYSTEM FURNITURE (POC) J (E)SYSTEM FURNITURE (POC) (E)ELEVATOR UNIT AND DISCONNECT V V V "C" 3 2 1 1 (EXR) ( E X R ) ( E X R ) ( E X R ) MEETING ROOM 202 PUBLIC AFFAIRS MANAGER 205 BOS. MANAGER 208 BREAK ROOM 207 INT. AFFAIRS LIEUT. 224 MENS 129 WOMENS 222 HALL STAIRS 144 SERVER 216 EQUIP. 220 BREAK ROOM 215CHIEF 214C ADMIN 214A DEPT. CHIEF 213 DEPT. CHIEF 211 ELEV. MECH 112 COPY ROOM 210 ELEV. CONF. 202 TRAIN/HIRING MANAGER 208 CRIME ANALYST 209 222 22 2 442 2 2 2 2 2 2 2 2 3 6 2 2 4 4 2 2 4 4 2 J J J 444 3 3 J 4 1 ED-102 5 5 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 1 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E D - 1 0 2 - 2 N D F L R P W R & S I G D E M O P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT REFERENCE NOTES 1.REMOVE EXISTING SURFACE MOUNT RACEWAY AT THIS AREA. 2.DISCONNECT EXISTING MOTORIZED SCREEN AND RECONNECT TO NEW LOCATION. 3.PROTECT EXISTING FLOOR BOXES IN THIS ROOM. 4.EXISTING WALL MOUNTED DATA RACK. PROVIDE AND INSTALL (1)24 CAT6A DATA PORT. HOMERUN ALL NEW SECOND FLOOR CAT6A TO THIS CABINET. 5.EXISTING SYSTEM FURNITURE CONNECTIONS. RE-USE (2) CAT6 CABLES AND TERMINATE TO NEW WALL TV OUTLETS. RE-USE THE REST OF THE CAT6 CABLES AND TERMINATE TO FACEPLATE AND STANDARD HEIGHT. FIELD VERIFY EXACT LOCATION OF SYSTEM FURNITURE. FURNITURE WERE IN THE WAY TO VERIFY IF THE SOUTH PILLAR HAD CONNECTIONS. RE-USE EXISTING BRANCH BRANCH CIRCUIT TO POWER NEW OUTLETS AT NEW WALL. NORTH SCALE: POWER / SIGNAL DEMOLITION SECOND FLOOR PLAN 3/16"=1'-0" PO W E R / S I G N A L D E M O L I T I O N S E C O N D F L O O R P L A N ED-102 NOTE: ALL DEVICES SHOWN ON THIS PAGE ARE EXISTING UNLESS OTHERWISE NOTED) EXISTING DATA RACK AT ELECTRICAL ROOM1 ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 TV TV TV TV J B-6,15 TV TV TV J A-3 1 J A-38,40 TV J 4 CLGCLG 3 2 11 5 (E) "A" (E) "MSB" (E) "FACP" 8 SF SF J 12 1 1 1 1 12 1 J B-3,26 B-3 B-3 B-3 B-3,26 B-3 B-3,26B-3(N)6 (N) 3 3 (N)(N) (E)(E) (E)(E) (E) B-3,26 B-26 (N) 3 3 3 3 3 3 3 3 3 3 (E) B-2 B-2 J B-10,11 B-10 B-10 3 B-10 J A-4 B-13 3 (E)(E)A-4B-8 (E) B-22 A-1 8 (N)6 (E)(E)(E) (E) A-20 A-20 A-20B-28 B-28 A-20 (E) (E) (E) (E) (E) (E) A-9 A-9 G G 10 6 CKT, B-6 CKT, B-6 CKT, B-6 CKT, B-6 CKT, B-15 CKT, B-6 CKT, B-15 CKT, B-15 CKT, B-15 CKT, B-15 (N)(N) (N) (N) (N) (N) (N)(N) (E) (N) (N) (N) (N) 6 (N) (N) (N)(N) (N) 9 7 7 (E) "B"8 SHARED OFFICE 126 BUREAU SERGEANT 107 DETECTIVE EQUIPMENT 106 DRONE/EQUIP. STORAGE 105 STAIR MEN 118 WOMEN 119 HALL 115 JAN. ELECTRICAL 120 CIRCULATION 130 BRIEFING ROOM 122 MEETING 125 OFFICE 124 ELEV. STAIR LOBBY 100 STORAGE 111 OPEN OFFICE BREAK ROOM 121 OFFICE 123 STORAGE 133 HALL 114 AP (N) AP (N) (N)G A-17 13 38 38 38 38 14 (N) 15 15 (E) 2 (E) 2 (E) 3 (E) 4 (E) 4 (E) 4 (E) 2 (E) 4222 (E) 2 (E) 4 6 6 (N) 40 2 19 18 18 17 CAM 16 (N) 21 J 5 (EXN) 20 18 (E)(E)(E) 21 5 1 ED-101 22 (E) (E) A-15 21 (N)6 (E) (E)(E) San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 1 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 1 0 1 - 1 S T F L R P W R & S I G F L R P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT REFERENCE NOTES 1.PROVIDE 120V DEDICATED CIRCUIT FOR DOOR ACCESS CONTROL PANEL. COORDINATE EXACT LOCATION WITH CITY VENDOR PRIOR TO ROUGH-IN. CONNECT TO EXISTING SPARE BREAKER AT PANEL "A". 2.CONNECT TO MOTORIZED SCREEN. COORDINATE WITH MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN. 3.MOTORIZED SCREEN CONTROLLER. PROVIDE WIRING TO MOTORIZED SCREEN PER MANUFACTURER INSTALLATION GUIDE. 4.PROVIDE 120V CONNECTION TO PROJECTOR. VERIFY EXACT LOCATION WITH OWNER PROVIDED EQUIPMENT. 5.EXTEND EXISTING BRANCH CIRCUIT. 6.SYSTEM FURNITURE POINT OF CONNECTION. RE-USE EXISTING BRANCH CIRCUITS LOCATED ABOVE T-BAR CEILING. INTERCEPT AND EXTEND BRANCH CIRCUITS TO SYSTEM FURNITURE. COORDINATE WITH SYSTEM FURNITURE MANUFACTURE. 7.REPLACE EXISTING OUTLET WITH NEW GFCI OUTLET AND COVERPLATE. 8.EXISTING PANEL. 9.EXTEND EXISTING RECEPTACLE BRANCH CIRCUIT IN THIS ROOM TO NEW OUTLET(S). 10.EXISTING DATA OUTLET BOX IN THIS SYSTEM FURNITURE. FIELD VERIFY EXACT LOCATION. PROVIDE (3)NEW CAT6A CABLES. TYPICAL AT SYSTEM FURNITURES. 11.THIS DATA OUTLET FOR SYSTEM FURNITURE WILL REQUIRE A BOX AND 1-1/5" CONDUIT TO ACCOMMODATE (12)CAT6A CABLES. 12.PROVIDE 120V DEDICATED CIRCUIT FOR MOTORIZED BLACK OUT SHADES. COORDINATE WITH MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN. 13.CONNECTION TO NEW DRINKING FOUNTAIN. EXTEND EXISTING CIRCUIT FROM BREAK ROOM OUTLET. 14.PROVIDE (2)20A/1P BREAKER TO MATCH EXISTING TO SPACES 38 AND 40. PROVIDE UPDATED TYPED PANEL SCHEDULE. 15.WIRELESS ACCESS POINT FURNISHED AND INSTALLED BY OWNER. EC TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE. PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE. 16.SECURITY CAMERA FURNISHED AND INSTALLED BY OWNER. EC TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE. PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE. 17.PROVIDE 15FT TELE-POWER ONE COMPARTMENT POLE FOR (18)CAT6A TO TERMINATE AT SYSTEM FURNITURE DATA OUTLET BOXES. (WIREMOLD 30TC-2WH) EC TO PROVIDE ALL ACCESSORIES FOR A COMPLETE WORKING SYSTEM. 18.INTERCEPT EXISTING BRANCH CIRCUIT AT ACCESSIBLE CEILING SPCE NEAR EXISTING PILLAR AND EXTEND TO NEW OUTLET(S). 19.RE-USE EXISTING CAT6 CABLES AND TERMINATE AT TV AND STANDARD HEIGHT. 20.NEW LOCATION OF EXISTING DATA OUTLETS. 21.REPLACE EXISTING DUPLEX OUTLET WITH DOUBLE DUPLEX. CHANGE BOX, RING, DEVICE AND PLATE. 22.INSTALL 2-3" (EMT) CONDUIT SLEEVES ABOVE T-BAR CEILING TO FIRST FLOOR DATA RACK FOR NEW LOW VOLTAGE WIRING. NORTH SCALE: POWER / SIGNAL FIRST FLOOR PLAN 3/16"=1'-0" PO W E R / S I G N A L F I R S T F L O O R P L A N E-101 NOTE: CUT AND PATCH EXISTING WALLS WHERE NEW OUTLETS ARE SHOWN. ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L UP UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 2 (E) (E) TV TV 3 8 (E) TV TV 3 TV TV 3 J J 3 CLGCLG (E)(E) (E)(E)(E) (E) (E) (E) (E) (E) (N) C-34,36 TV (E) (EXN) 3 C-38 11 1 (E) "C" 1 (E) "D" 4 5 6 10 (E) (E) 7 7 7 (E) DS 1 (IDU) 208V, 1ɸ 0.5 MCA 15 MOCP 2 12 M 13 C-40/42 14 15 36 34 36 36 36 34 16 (E) G (E) G 17 17 2 (N) (N) (N)(N) 3 3 (N) (N) (N) (N) (E) 3 (E)(E) (E)(E)(E) (E) 6 1 1 6 1M (EX N ) (EX N ) (EX N ) (N) 31 M (N) G,M (N) G,M G,M G,M 18 (EXN) MEETING ROOM 202 PUBLIC AFFAIRS MANAGER 205 BOS. MANAGER 208 BREAK ROOM 207 INT. AFFAIRS LIEUT. 224 MENS 129 WOMENS 222 HALL STAIRS 144 SERVER 216 EQUIP. 220 BREAK ROOM 215 CHIEF 214C ADMIN 214A DEPT. CHIEF 213 DEPT. CHIEF 211 ELEV. MECH 112 COPY ROOM 210 ELEV. CONF. 202 TRAIN/HIRING MANAGER 208 CRIME ANALYST 209 JAN. (E) (E) TV TV 3 1 (E) (E)(E)(E)(E) AP (N) AP (N) 19 19 J J J 4 4 4 (E)(E)(E) 20 (E) 2 (E) 2 (E) 2 (E) 2 (E) 2 (E) 2 (N) 36(E) 6 (E) 2 (E) 4 (E) 4 (E) 2 (E) 2 M 2 (E) 2 (E) 2 (E) 2 (E) 2 (E) 2 (E) 2 (E) 3 (E) 6 (E) 2 (E) 2 (E) 4 (E) 4 (E) 2 W 2 (E) 4 (E) 4 3 22 22 22 6 6 23 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 1 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 1 0 2 - 2 N D F L R P W R & S I G F L R P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT REFERENCE NOTES 1.EXISTING BRANCH CIRCUIT PANELBOARD. 2.REPLACE EXISTING DUPLEX OUTLET WITH NEW DOUBLE DUPLEX OUTLET. 3.EXTEND EXISTING RECEPTACLE BRANCH CIRCUIT IN THIS ROOM TO NEW OUTLET(S). 4.CONNECT TO MOTORIZED SCREEN. COORDINATE WITH MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN. 5.MOTORIZED SCREEN CONTROLLER. PROVIDE WIRING TO MOTORIZED SCREEN PER MANUFACTURER INSTALLATION GUIDE. 6.PROVIDE 120V CONNECTION TO PROJECTOR. VERIFY EXACT LOCATION WITH OWNER PROVIDED EQUIPMENT. 7.RE-USE EXISTING BRANCH CIRCUIT FROM EXISTING SYSTEM FURNITURE CONNECTION. 8.RELOCATE EXISTING RECEPTACLE AND DATA OUTLET TO BE ABOVE NEW COUNTER SPACE. INTERCEPT EXISTING BRANCH CIRCUIT TO NEW LOCATION. PROVIDE NEW DUPLEX DEVICE AND PLATE. 9.NOT USED. 10.LOCATE FOR NEW COPIER. 11.PROVIDE NEW DEDICATED CIRCUIT AND OUTLET FOR EXISTING REFRIGERATOR. 12.EXISTING WALL MOUNTED DATA RACK. 13.PROVIDE LINE VOLTAGE CONNECTION TO MECHANICAL UNIT. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION WITH MECHANICAL PLANS AND PROVIDE 2-POLE, NEMA 1 DISCONNECT PER MANUFACTURER'S REQUIREMENTS. 14.NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C". PROVIDE NEW 20A/2P CIRCUIT BREAKER IN PANEL AS DESIGNATED TO MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1) #12 CU GROUND. 15.NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C". PROVIDE NEW 20A/1P CIRCUIT BREAKER IN PANEL AS DESIGNATED TO MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1) #12 CU GROUND. 16.NEW 20A BRANCH CIRCUITS TO EXISTING PANEL "C". PROVIDE (2) NEW 20A/1P CIRCUIT BREAKERS IN PANEL AS DESIGNATED TO MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (4) #12 THWN AND (1) #12 CU GROUND. 17.REPLACE EXISTING OUTLET WITH NEW GFCI OUTLET AND COVER. 18.REPLACE EXISTING SWITCH AND OUTLET WITH NEW DEVICE AND PLATES. PROVIDE NEW OUTLET AS SHOWN AND EXTEND EXISTING BRANCH CIRCUIT. RE-USE EXISTING BRANCH CIRCUIT FROM EXISTING OUTLET IN THIS LOCATION. 19.WIRELESS ACCESS POINT FURNISHED AND INSTALLED BY OWNER. EC TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE. PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE. 20.MOVE EXISTING OUTLET TO NEW WALL. INTERCEPT EXISTING BRANCH CIRCUIT AND EXTEND TO NEW LOCATION. PROVIDE NEW DEVICE AND COVER PLATE. 21.RE-USE EXISTING CAT6 CABLES AND TERMINATE AT NEW TV OUTLET 22.TERMINATE ALL EXISTING CAT6 AT EXISTING SYSTEM FURNITURE LOCATION AT WALL OUTLET AT STANDARD HEIGHT. ASSUMED (26)EXISTING CAT6 CABLES FROM EXISTING SYSTEM FURNITURE. 23.PROVIDE 2"C (EMT) SLEEVE ABOVE T-BARD CEILING FROM 2ND FLOOR DATA CABINET FOR NEW CAT6A CABLES. NORTH SCALE: POWER / SIGNAL SECOND FLOOR PLAN 3/16"=1'-0" PO W E R / S I G N A L S E C O N D F L O O R P L A N E-102 NOTE: CUT AND PATCH EXISTING WALLS WHERE NEW OUTLETS ARE SHOWN. ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 4 - OS OS (EXR)(EXR)(EXR) (TBR) (TBR)(TBR) 3 - (TBR) (TBR) SHARED OFFICE BUREAU SERGEANT 107 DETECTIVE EQUIPMENT 106 DRONE/EQUIP. STORAGE 105 STAIR MEN 118 WOMEN 119 HALL 115 JAN. ELECTRICAL 120 CIRCULATION 130 BRIEFING ROOM '122 MEETING 125 OFFICE 124 ELEV. STAIR LOBBY 100 STORAGE 111 OPEN OFFICE BREAK ROOM OFFICE HALL 2 - 3 (EXR) 2 OS OS (EXR)3 (EXR) (NL) (NL) X2 (NL) (NL) 6 (N)XM (N) (NL) (NL) XM 7 4 4 OS 4 OS (N) XME 9 (NL) 10 10 10 10 (E)(E)(E)(E)(E) (E)(E)(E)(E)(E) (E)(E)(E)(E)(E) (E) (E) (E)(E) (E) (E) (E) (E)(E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E)(E)(E) (E) (E) (E)(E) (E) (E) (E)(E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG10 10 10(N) CLG (N) XM 7 5 - (EXR) 12 (EXN)(EXN)(EXN)RPP WS WS,D (N) WS OSOSOSOS WS OSOSOSOS 1 SHARED OFFICE SHARED OFFICE 126 BUREAU SERGEANT OS D1 W1 D1 1 1 W1 MEN 118 WOMEN 119 OS OS OS XM XMEOS X2 (EXN)(EXN) 9 (N)XM 10 6 4 4 4 OS 4 (N)XM 10 (N) XM 10 (E) (E) (E) (E) (E) (E) (E)(E) J 11 (N)X2 (EXN) (NL) 5 (EXN) 9 (N) X1 X2 (E) (E) (E) (EXN) (NL) (N) XME (N) XM CLG J OS (E) (EXN) 12 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 2 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 1 1 1 - 1 S T F L R L T G P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT 1 EXISTING FIRST FLOOR LIGHTING PLAN SCALE: 1/8"=1'-0" 4 PARTIAL FIRST FLOOR LIGHTING PLAN AT SHARED OFFICE SCALE: 1/4"=1'-0" REFERENCE NOTES 1.EXTEND EXISTING LIGHTING BRANCH CIRCUIT IN THIS ROOM TO NEW LIGHT FIXTURES AND ASSOCIATED CONTROLS. 2.REPLACE EXISTING EXIT SIGN WITH EMERGENCY WITH NEW. 3.REMOVE WALL MOUNTED EXIT SIGN. PROVIDE NEW CEILING MOUNT EXIT SIGN AT NEW LOCATION. EXTEND EXISTING BRANCH CIRCUIT AT NEW LOCATION. 4.REPLACE EXISTING OCCUPANCY SENSOR WITH NEW ULTRASONIC OCCUPANCY SENSOR. 5.THESE SWITCHES CONTROL THE EXISTING DOWNLIGHTS AT OPEN OFFICE. LABEL SWITCHES. 6.REPLACE EXISTING EMERGENCY LIGHTING WITH NEW. 7.PROVIDE NEW EMERGENCY LIGHTING AT MID STAIR LANDING. EXTEND EXISTING BRANCH CIRCUIT. 8.EXISTING EMERGENCY LIGHTING WAS CONNECTED TO AN OUTLET. DISCONNECT AND REMOVE AND EXTEND EXISTING BRANCH CIRCUIT FROM EXISTING LIGHT IN THE SAME ROOM. 9.PROVIDE NEW EXTERIOR EMERGENCY LIGHTING EXTEND EXISTING BRANCH CIRCUIT FROM NEAREST UNSWITCHED LIGHTING BRANCH CIRCUIT. 10.PROVIDE NEW INTERIOR EMERGENCY LIGHTING. EXTEND EXISTING BRANCH CIRCUIT FROM UNSWITCHED LIGHTING BRANCH CIRCUIT. 11.PROVIDE NEW INTERIOR EXIT SIGN WITH EMERGENCY LIGHTING. EXTEND EXISTING BRANCH CIRCUIT FROM UNSWITCHED LIGHTING BRANCH CIRCUIT. 12.EXISTING SWITCH TO BE RELOCATED TO NEW WALL. EXTEND LIGHT EXISTING BRANCH CIRCUIT TO NEW LOCATION. BLANK EXISTING SWITCH LOCATION. PROVIDE NEW OCCUPANCY WALL SWITCH. L I G H T I N G F I R S T F L O O R P L A N E-111 PARTIAL FIRST FLOOR 3 LIGHTING PLAN AT RESTROOMS SCALE: 1/4"=1'-0" NORTH PARTIAL FIRST FLOOR 2 LIGHTING PLAN AT LOBBY SCALE: 1/4"=1'-0" 5 LIGHTING PLAN AT STORAGE 11 SCALE: 1/4"=1'-0" PARTIAL FIRST FLOOR ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L UP 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 3 - 2 - MEETING ROOM 202 PUBLIC AFFAIRS MANAGER 205 BOS. MANAGER 208 BREAK ROOM 207 INT. AFFAIRS LIEUT. 224 MENS 129 WOMENS 222 HALL STAIRS 144 SERVER 216 EQUIP. 220 BREAK ROOM 215CHIEF 214C ADMIN 214A DEPT. CHIEF 213 DEPT. CHIEF 211ELEV. MECH 112 COPY ROOM 210 ELEV. CONF. 202 TRAIN/HIRING MANAGER 208 CRIME ANALYST 209 (NL) (NL) (NL) (NL) (NL) 2 (NL) (TBR)(TBR) (TBR) (TBR) (TBR)(EXR) 3 3 (EXR) (EXR) (EXR) (E) XM 4 4 4 4 4 XM4 (TBR) (TBR) (E)(E) (E)(E) (E)(E) (E)(E) (E)(E) (E)(E) (E)(E)(E) (E)(E)(E)(E)(E)(E) (E) (E)(E)(E)(E) (E)(E)(E)(E) (E) (E) (E)(E)(E) (E) (E) (E)(E) (E)(E) (E) (E)(E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (TBR) (TBR) (E) (E)(E) (E) (E)(E) (E) (E) (E)(E) (E) (E) (N) XM (CLG) (N)XM (CLG) (N)XM (CLG) (N)XM (CLG) (N)XM (CLG) (N)XM (CLG) (N)XM (CLG) 4 2 (N) XM (CLG) 4 (E) (E)(E) (E)(E)(E) (E)(E) (E) (E)(E) (E)(E) (E)(E) (E) (E) WS OSOSOSOS WS OSOSOSOS WS,D RPP WS RPP WS WS,D WS,D a a aa b b bb b b b a 1 1 CHIEF 214C ADMIN 214A (EXN) W1 D1 D1 D1 D1 D1 D1 D1 D1 W2 OS LV OS LV LV LV 1 1 OS LV PP OS LV LV LV LV MENS 129 WOMENS 222 JAN. (EXN) (EXN) 5 6 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 2 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 1 1 2 - 2 N D F L R L T G P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT 1 EXISTING SECOND FLOOR LIGHTING FLOOR PLAN SCALE: 1/8"=1'-0" 3 PARTIAL SECOND FLOOR LIGHTING PLAN @ ADMIN/CHIEF SCALE: 1/4"=1'-0" BATTERY POWERD WALL DIMMER, 1 GANG 1-POLE 0-10V DIMMING (NLIGHT AIR #RPODB DX) WS D,WS WIRELESS POWER RELAY PACK. 0-10V DIMMING (NLIGHT AIR #RPP20) RPP WS OSOSOSOS CEILING OCC SENSOR BATTERY POWERED (NLIGHT AIR #RCMSB 7 AR) LIGHTING CONTROL SYMBOLS LEGEND (EXR) = EXISTING TO BE RELOCATED (EXN) = EXISTING NEW LOCATION (E) = EXISTING (E)EXISTING SWITCH TO REMAIN (TBR)EXISTING SWITCH TO BE REMOVED LI G H T I N G S E C O N D F L O O R P L A N E-112 PARTIAL SECOND FLOOR 2 LIGHTING PLAN AT RESTROOMS SCALE: 1/4"=1'-0" REFERENCE NOTES 1.EXTEND EXISTING LIGHTING BRANCH CIRCUIT IN THIS ROOM TO NEW LIGHT FIXTURES AND ASSOCIATED CONTROLS. 2.REPLACE EXISTING EMERGENCY LIGHTING WITH NEW. 3.EXISTING SWITCH TO REPLACE WITH NEW DEVICE AND COVER PLATE. 4.PROVIDE NEW EMERGENCY LIGHT. EXTEND BRANCH CIRCUIT FROM UNSWITCH LIGHTING BRANCH CIRCUIT. 5.NEW LOCATION OF EXISTING EXIT SIGN. COVER CHEVRON. INTERCEPT EXISTING BRANCH CIRCUIT FROM OLD LOCATION AND EXTEND TO NEW LOCATION. 6.NEW LOCATION OF EXISTING LIGHT. INTERCEPT EXISTING BRANCH CIRCUIT FROM OLD LOCATION AND EXTEND TO NEW LOCATION. NORTH ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L 3.4 2.4 2.1 2.5 5.1 8.8 4.4 2.7 0.8 1.0 0.9 0.8 5.8 3.1 2.5 2.7 5.1 1.00.30.3 0.8 0.2 0.7 2.4 3.74.2 2.3 1.2 1.1 2.0 7.4 10.4 9.8 6.2 1.6 0.9 1.7 4.4 10.7 4.5 1.5 2.6 2.9 9.1 9.7 1.27.27.16.5 4.1 4.5 3.7 3.4 3.7 1.0 2.5 2.5 2.8 3.6 1.2 8.9 6.0 5.6 1.6 2.9 3.1 3.6 4.6 6.5 4.2 2.4 1.5 1.2 1.1 0.8 0.6 0.4 0.4 0.3 0.5 0.9 1.4 2.0 1.7 1.4 0.9 0.6 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.6 0.9 1.3 1.8 3.1 4.4 5.2 5.2 0.7 0.5 0.8 1.6 7.0 3.30.90.40.20.20.20.20.20.20.20.30.50.9 1.4 1.7 1.2 0.8 0.6 0.8 1.2 1.7 1.3 0.8 0.6 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.7 0.9 1.5 1.5 1.0 0.7 0.7 1.1 1.8 2.7 2.9 1.0 2.0 4.1 9.3 5.23.01.81.21.1 3.4 2.4 2.1 2.5 5.1 8.8 4.4 2.7 0.8 1.0 0.9 0.8 5.8 3.1 2.5 2.7 5.1 1.00.30.3 0.8 0.2 0.7 2.4 3.74.2 2.3 1.2 1.1 2.0 7.4 10.4 9.8 6.2 1.6 0.9 1.7 4.4 10.7 4.5 1.5 2.6 2.9 9.1 9.7 1.27.27.16.5 4.1 4.5 3.7 3.4 3.7 1.0 2.5 2.5 2.8 3.6 1.2 8.9 6.0 5.6 1.6 2.9 3.1 3.6 4.6 6.5 4.2 2.4 1.5 1.2 1.1 0.8 0.6 0.4 0.4 0.3 0.5 0.9 1.4 2.0 1.7 1.4 0.9 0.6 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.6 0.9 1.3 1.8 3.1 4.4 5.2 5.2 0.7 0.5 0.8 1.6 7.0 3.30.90.40.20.20.20.20.20.20.20.30.50.9 1.4 1.7 1.2 0.8 0.6 0.8 1.2 1.7 1.3 0.8 0.6 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.7 0.9 1.5 1.5 1.0 0.7 0.7 1.1 1.8 2.7 2.9 1.0 2.0 4.1 9.3 5.23.01.81.21.1 X2 (N)XM (N)XM (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG (N) XM CLG (N)XM X2 (EXN) (N)XM (N)XM (N) XM (N)X2 (N) X1 X2 (N) XM CLG 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 (N) (N)XM (N)XME (N)XME (N)XME 14.1 1.9 1.1 1.1 2.8 13.2 11.1 2.6 1.3 1.1 1.2 4.4 2.2 1.8 1.7 1.9 2.2 4.0 4.2 1.6 0.9 0.9 0.8 0.8 1.3 9.1 19.7 4.0 2.51.11.11.11.12.0 3.1 2.2 7.2 3.52.52.8 1.8 2.6 1.3 0.7 0.6 0.7 1.1 3.2 3.9 4.3 1.7 1.0 1.0 1.0 1.4 3.7 19.2 12.4 4.9 2.0 3.1 16.8 14.1 1.9 1.1 1.1 2.8 13.2 11.1 2.6 1.3 1.1 1.2 4.4 2.2 1.8 1.7 1.9 2.2 4.0 4.2 1.6 0.9 0.9 0.8 0.8 1.3 9.1 19.7 4.0 2.51.11.11.11.12.0 3.1 2.2 7.2 3.52.52.8 1.8 2.6 1.3 0.7 0.6 0.7 1.1 3.2 3.9 4.3 1.7 1.0 1.0 1.0 1.4 3.7 19.2 12.4 4.9 2.0 3.1 16.8 (EXN)XM 4 4 (E) (N) XM (CLG) (N)XM (CLG) (N)XM (CLG) (N)XM (CLG) (N)XM (CLG) (N)XM (CLG) (N) XM (CLG) (N)XM (CLG) XM UP UP 1 1 A B G 4 5 14 15 18 18 E D 6 13 8 11 3 16791012 F 2 2 C 17 17 (E) 1 1 (E) San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 2 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 1 1 3 - L T G E M P H O T O M E T R I C S P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT 1 FIRST FLOOR EM PHOTOMETRIC PLAN SCALE: 1/8"=1'-0" L I G H T I N G E M E R G E N C Y P H O T O M E T R I C P L A N E-113 NORTH 2 SECOND FLOOR EM PHOTOMETRIC PLAN SCALE: 1/8"=1'-0" CBC 1008.3.5 ILLUMINATION LEVEL UNDER EMERGENCY POWER EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGE TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT ANY POINT0.1 FOOT-CANDLE MEASURE ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATION OF 40 TO 1 SHALL NOT BE EXCEEDED. LEGEND EMERGENCY LIGHT WITH 90 MINUTE BATTERY BACK-UP EXIT SIGN WITH EMERGENCY LIGHT AND 90 MINUTE BATTERY BACK-UP EXIT SIGN WITH 90 MINUTE BATTERY BACK-UP REFERENCE NOTES 1.REFER TO 1ST FLOOR STAIRWELL FOR LIGHT LEVELS UNDER EMERGENCY. 1 ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L 1 1 A A B B G G 4 5 14 15 18 18 E E D D 6 13 8 11 3 16791012 F F 2 2 C C 17 17 DS 1 (ODU) 208V, 1ɸ 16.5 MCA 20 MOCP 1C-39/41 2 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 2 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 1 2 1 - R O O F P L N . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT EL E C T R I C A L R O O F P L A N E-121 REFERENCE NOTES 1.PROVIDE LINE VOLTAGE CONNECTION TO MECHANICAL UNIT. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION WITH MECHANICAL PLANS AND PROVIDE 2-POLE, NEMA 3R DISCONNECT PER MANUFACTURER'S REQUIREMENTS. 2.NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C". PROVIDE NEW 20A/2P CIRCUIT BREAKER IN PANEL AS DESIGNATED TO MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1) #12 CU GROUND. NORTH SCALE: POWER SIGNAL SECOND FLOOR PLAN 3/16"=1'-0" ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 2 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 2 0 1 - E L E C D E T A I L S . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT 3 TYPICAL DEVICE ADA MOUNTING HEIGHTS SCALE: NTS 34 " M A X I M U M 46 " M A X I M U M - S I D E R E A C H 24" MAXIMUM MOUNTING HEIGHT OVER OBSTRUCTION 15 " MI N I M U M TO BOTTOM OF WIRING DEVICE OUTLET BOX TO TOP OF SWITCH, THERMOSTAT, OUTLET, OR CONTROL DEVICE TO TOP OF SWITCH, THERMOSTAT, OUTLET, OR CONTROL DEVICE FINISH FLOOR FINISH FLOOR * N O F O R W A R D R E A C H A L L O W E D 48 " MA X I M U M UN L E S S K N E E S P A C E I S P R O V I D E D * 2 7 " C L R FIXTURES LESS THAN 50 LBS PROVIDE POSITIVE FASTENING TO T-BAR GRID AT EACH END OF FIXTURE. ATTACH WITH #8 FLAT HEAD SHEET METAL SCREW T-BAR CEILING GRID, SEE ARCHITECTURAL REFLECTED CEILING PLANS. LIGHTING FIXTURE PER FIXTURE SCHEDULES. REFER TO ARCHITECTURAL DETAILS FOR ATTACHMENT TO STRUCTURE. CEILING SUPPORT WIRES. MINIMUM (3) TIGHT TURNS IN 1-1/2". HEAVY DUTY GRID SYSTEM PROVIDE #12 GA. SLACK SUPPORT WIRES AT 2 DIAGONALLY OPPOSITE CORNERS FOR FIXTURES UP TO 50 LBS. (FIXTURES ABOVE 50 LBS. SHALL BE INDEPENDENTLY SUPPORTED AS NOTED BELOW). AT STUD WALL AT CMU WALL REFERENCE NOTES HEIGHT SEE ARCH. PLANS FOR MOUNTING OUTLET BOX PROVIDE #10x1" HEX HEAD SELF-TAPPING SCREWS AT FIXTURE MOUNTING POINTS. (MINIMUM OF 2) TO BACKING OR WALL STUDS METAL WALL STUD, SEE ARCH. PLANS. WALL FINISH, SEE ARCH. PLANS. WALL STUD BACKING PER 14-X/S105. 1.SMALL SURFACE MOUNTED LIGHT FIXTURE. (20 LBS. OR LESS) 2.CONCRETE MASONRY WALL. 3.3/8" DIA. HILTI KB3 , PER ICC ESR-2302. PROVIDE MINIMUM 2-1/2" EMBEDMENT. NOTE: FLUSH MOUNTED OUTLET BOX IS NOT SHOWN FOR CLARIFICATION. LIGHTING FIXTURE PER FIXTURE SCHEDULE ON SHEET X/E105. PLAN PLAN FIRE PUTTY IS NOT REQUIRED IF ONLY ONE BOX IS INSTALLED ON EITHER SIDE OF 100 SF OF WALL. 2 1 3 WRAP FIRE PUTTY PADS OVER FITTING WRAP FIRESTOP PUTTY PADS OVER ENTIRE BOX. OVERLAP ON TOP, BOTTOM & SIDES. OUTLET BOX. REFER TO PLANS AND SPECIFICATION FOR TYPE, SIZE & QUANTITY. PROVIDE 1/4" BEAD OF INSULATING PUTTY TO SEAL BETWEEN PLASTER RING & DRYWALL FILL GAP BETWEEN PLASTER RING AND DRYWALL WITH PLASTER PLASTER RING. REFER TO ARCHITECTURAL PLANS FOR WALL TYPE AND PROVIDE RING DEPTH TO MATCH DRYWALL DEPTH FLUSH MOUNTED J-BOX FINISH WALL 6 DEVICE INSTALLATION - RATED WALLS SCALE: NTS 5 LAY-IN BAR FIXTURE MOUNTING DETAIL SCALE: NTS 4 SURFACE MOUNT FIXTURE DETAIL SCALE: NTS 9 IMAGE AT ROOM 202 8 IMAGE AT ROOM 214 7 IMAGE AT ROOM 123 12 TYPICAL MODULAR FUNITURE FEED DETAIL 10 IMAGE AT OPEN OFFICE FLOOR LIQUID-TIGHT FLEXIBLE CONDUIT 90° CONDUIT CONNECTOR-REVERSIBLE (PROTRUDES WIDTH OF CONDUIT) CONNECTION DISTRIBUTION HARNESS INSET BUILDING WALL TO PANEL BASE LIQUID-TIGHT FLEXIBLE CONDUIT PARTITION CONNECTION, SEE INSET IF NOT PRE-PUNCHED, USE HOLE SAW OR PUNCH TO MAKE HOLE FOR FLEX FITTING. INSTALL CABLES INTO FURNITURE CABLE CHANNEL. FLUSH, WALL MOUNTED POWER FEED J-BOX WITH EXTENSION BOX. SEE PLAN FOR NUMBER OF CIRCUITS. FLUSH, WALL MOUNTED COMMUNICATIONS FEED J-BOX WITH EXTENSION BOX. SEE COMMUNICATIONS PLAN FOR NUMBER OF CABLES. CARLON FLEX CONDUIT, SAME SIZE AS RACEWAY IN WALL, WITH COMMUNICATIONS CABLE. RECEPTACLE LOCATIONS EL E C T R I C A L D E T A I L S E-201 EXISTING 14-CAT6 CABLES. REMOVED CABLES AND DISCONNECT AT "MDF" IN ELECTRICAL ROOM. DO NOT CUT CABLES. 11 1 SCALE: NTS 2 ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com Fax: (805) 543-3829 S e p 1 3 , 2 0 2 4 - 1 2 : 4 2 p m - C h r i s - K : \ E N G \ 2 0 2 4 \ 2 4 - 8 0 2 6 \ 2 4 - 8 0 2 6 _ E - 3 0 1 - T 2 4 F O R M S . d w g 2000577-04 11 0 6 W A L N U T T E N A N T I M P R O V E M E N T CITY SPECIFICATION NO. DATE: PR O J E C T T I T L E : SH E E T T I T L E : SHEET NO. DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION As indicated TR 6/20/2024 CJ ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L EXPIRES: 09/30/26 THOMA #24-8026 CJ JT TI T L E 2 4 E N E R G Y F O R M S - I N T E R I O R L I G H T I N G E-301 ERE TYM.E C F NO. 20823 EL T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS LERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L ERE TYM.E C F NO. 20823 E L T S OE A T E SIGER EJ FTF RE A RO L I CRT IL FCA AIN H O M N A RE E G I N ORPD NA OIEFSS L