Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FA
JMG SECURITY SYSTEMS Re p o r t N u m b e r 60 6 6 0 1 3 17150 NEWHOPE ST STE 109 FOUNTAIN VALLEY, CA 92708-4273 (714) 545-8882 x318 Occupancy Information Name:GRADUATE 990 INDUSTRIAL WAY SAN LUIS OBISPO, CA 93401-7602 Contact:Responsible Person KEN FONTES GRADUATE INC 3650 SACRAMENTO DRIVE SAN LUIS OBISPO, CA 93401 Phone:(805) 440-3885 Fire Alarm Service Date July 19, 2024 Report Number:6066013 AHJ:SAN LUIS OBISPO CITY FIRE DEPARTMENT 2160 SANTA BARBARA AVE SAN LUIS OBISPO, CA 93401-5240 Status:Compliant Phone:(805) 781-7386 Report Type:S - (Semi-Annual) Fire Alarm Reviewed by AHJ:Yes, July 26, 2024 Code Reference:NFPA 72 Inspection & Testing Agency Information Name:JMG SECURITY SYSTEMS 17150 NEWHOPE ST STE 109 FOUNTAIN VALLEY, CA 92708-4273 Phone:(714) 545-8882 x318 Emergency Phone:(714) 614-7734 Email:jzambrano@jmgsecurity.com Licenses:License Type License Number Expiration California - C10 575070 08/31/2025 California - City of Murrieta Business License 33627 02/01/2025 City of Oceanside Business License BL-104710 04/30/2025 City of Huntington Beach Business License A116978 03/31/2025 City of Oxnard Business License 24-00133145 02/28/2025 Inspector/Tester Information Name:JUAN ZAMBRANO Phone:(714) 545-8882 x318 Problems Found Question #Code Ref(s)Question Answer Impairment Corrected No problems found. Are there any deficiencies or issues listed in your FIRE ALARM report? No Attach original copy of your inspection, testing and maintenance FIRE ALARM report (one system per report). NOTE: Files up to 50MB may be attached. A file has not been attached until the “cancel” button is cleared and the file is clickable in the report. Larger files will take longer to upload. Recommended scanner settings: 100 dpi / gray scale for improved user experience. Page 1 of 1Printed from The Compliance Engine Powered by BRYCER Report Number 6066013 Mon Nov 18 12:03:31 CST 2024 by HUTCHINSON, JULIANNA SYSTEM RECORD OF INSPECTION AND TESTING This form is to be completed by the system inspection and testing contractor at the time of a system test. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1 of 4) Inspection/Test Start Date/Time: 7-19-2024 @ 9:46am Inspection/Test Completion Date/Time: 7-19-2024 @ 10:30am Supplemental Form(s) Attached: Yes (yes/no) 1. PROPERTY INFORMATION Name of property: Zoo Med Laboratories Inc. Address: 990 Industrail Way, San Luis Obispo, CA 93401 Description of property: Commercial Name of property representative: Zoo Med Laboratories Inc Address: 3650 Sacramento Dr. San Luis Obispo, CA 93401 Phone: 805-542-9988 Fax: N/A E-mail: Paul@zoomed.com 2. TESTING AND MONITORING INFORMATION Testing organization: JMG Security Systems Address: 17150 Newhope Street Suite 109 Fountain Valley, CA Phone: 714-545-8882 Fax: 714-545-0352 E-mail: Jzambrano@jmgsecurity.com Monitoring organization: NMC Address: 25341 Commercentre Drive Lake Forest, CA 92630 Phone: 1-800-662-1711 Fax: N/A E-mail: N/A Account number: JMGA8970 Phone line 1: RadioMesh Phone line 2: RadioMesh Means of transmission: RadioMesh Entity to which alarms are retransmitted: N/A Phone: N/A 3. DOCUMENTATION On-site location of the required record documents and site-specific software: N/A 4. DESCRIPTION OF SYSTEM OR SERVICE 4.1 Control Unit Manufacturer: Silent Knight Model number: SK6700 4.2 Software and Firmware Firmware revision number: N/A 4.3 System Power 4.3.1 Primary (Main) Power Nominal voltage: 120 Amps: 20 Location: NA Overcurrent protection type: Fusible Amps: 20 Disconnecting means location: Breakers SYSTEM RECORD OF INSPECTION AND TESTING (continued) Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2 of 4) 4. DESCRIPTION OF SYSTEM OR SERVICE (continued) 4.3.2 Secondary Power Type: Sealed Lead Acid Location: Phone Room Battery type (if applicable): (2) 18AH-12V - (1) 12AH - 12V Calculated capacity of batteries to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5. NOTIFICATIONS MADE PRIOR TO TESTING Monitoring organization Contact: National Monitoring Center Time: 9:46 am Building management Contact: N/A Time: N/A Building occupants Contact: N/A Time: N/A Authority having jurisdiction Contact: N/A Time: N/A Other, if required Contact: N/A Time: N/A 6. TESTING RESULTS 6.1 Control Unit and Related Equipment Description Visual Inspection Functional Test Comments Control unit Passed Lamps/LEDs/LCDs Passed Fuses Passed Trouble signals Passed Disconnect switches Passed Ground-fault monitoring Passed Supervision Passed Local annunciator Passed Remote annunciators Passed Remote power panels Passed 6.2 Secondary Power Description Visual Inspection Functional Test Comments Battery condition Passed Load voltage Passed Discharge test Passed Charger test Passed Remote panel batteries Passed SYSTEM RECORD OF INSPECTION AND TESTING (continued) Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 3 of 4) 6. TESTING RESULTS (continued) 6.3 Alarm and Supervisory Alarm Initiating Device Attach supplementary device test sheets for all initiating devices. 6.4 Notification Appliances Attach supplementary appliance test sheets for all notification appliances. 6.5 Interface Equipment Attach supplementary interface component test sheets for all interface components. Circuit Interface / Signaling Line Circuit Interface / Fire Alarm Control Interface 6.6 Supervising Station Monitoring Description Yes No Time Comments Alarm signal Passed Alarm restoration Passed Trouble signal Passed Trouble restoration Passed Supervisory signal Passed Supervisory restoration Passed 6.7 Public Emergency Alarm Reporting System Description Yes No Time Comments Alarm signal Passed Alarm restoration Passed Trouble signal Passed Trouble restoration Passed Supervisory signal Passed Supervisory restoration Passed SYSTEM RECORD OF INSPECTION AND TESTING (continued) Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 4 of 4) 7. NOTIFICATIONS THAT TESTING IS COMPLETE Monitoring organization Contact: National Monitoring Center Time: 10:30 am Building management Contact: N/A Time: N/A Building occupants Contact: N/A Time: N/A Authority having jurisdiction Contact: N/A Time: N/A Other, if required Contact: N/A Time: N/A 8. SYSTEM RESTORED TO NORMAL OPERATION Date: 7-19-2024 Time: 10:30 am 9. CERTIFICATION This system as specified herein has been inspected and tested according to NFPA 72, 2013 edition, Chapter 14. Signed: Juan Zambrano Printed name: Juan Zambrano Date: 7-19-2024 Organization: JMG Security Systems Title: Fire Test Supervisor Phone: 714-614-7734 Qualifications (refer to 10.5.3): 10. DEFECTS OR MALFUNCTIONS NOT CORRECTED AT CONCLUSION OF SYSTEM INSPECTION, TESTING, OR MAINTENANCE 10.1 Acceptance by Owner or Owner’s Representative: The undersigned accepted the test report for the system as specified herein: Signed: Printed name: Date: Organization: Title: Phone: