HomeMy WebLinkAbout3055 Garibaldi Ave Fire ReportNFIRS-1 Basic
40060 CA 12 25 2024 Fire Station
3 (FS3)
24-07396 0
FDID State Month Day Year Station Number Exposure
Location Type
Census tract:
Street Address
Intersection
In Front Of
Rear Of
Adjacent To
Directions
US National Grid
3057 GARIBALDI
Number Prefix Street or Highway Street Type Suffix
San Luis Obispo CA 93401
Apt./Suite/Room City State Zip Code
Cross Street
Incident Type
100-Fire, other
Aid Given Or Received
1 Mutual Aid Received
2 Auto. Aid Received
3 Mutual Aid Given
4 Auto. Aid Given
5 Other Aid Given
None
Their FDID Their
State
Their Incident Number
Dates and Times
Alarm 12 25 2024 21:35
Arrival 12 25 2024 21:41
Controlled 12 25 2024 21:42
Last Unit
Cleared
12 25 2024 22:39
Shifts and Alarms
C NA FZ3
Shift or
Platoon
Alarms District
Special Studies
9244 4 - Unknown
ID#Value
A
B
C
D
E1 E2
E3
Page 1 of 8
Actions Taken
12-Salvage & overhaul
Primary Action Taken
Resources
Apparatus or Personnel Module is used.
Apparatus Personnel
Suppression 3 10
EMS 0 0
Other 0 0
Resource counts include aid received
resources.
Estimated Dollar Losses and Values
Losses:Required for all fires if
known. Optional for all
non-fires.
None
Property:$
Contents:$
Pre-Incident Values: Optional None
Property:$ 800,000.00
Contents:$
Completed Modules
2 - Fire
3 - Structure Fire
4 - Civilian Fire Cas.
5 - Fire Service Cas.
6 - EMS
7 - HazMat
8 - Wildland Fire
9 - Apparatus
10 - Personnel
11 - Arson
Casualties None
Deaths Injuries
Fire
Service
0 0
Civilian 0 0
Detector
Required for Confined Fires
1 - Detector Alerted Occupants
2 - Detector Did Not Alert Them
3 - Unknown
Hazardous Materials Release
1 - Natural Gas
2 - Propane Gas
3 - Gasoline
4 - Kerosene
5 - Diesel Fuel / Fuel Oil
6 - Household Solvents
7 - Motor Oil
8 - Paint
0 - Other
None
Mixed Use Property
Not Mixed
10 - Assembly Use
20 - Education Use
33 - Medical Use
40 - Residential Use
51 - Row Of Stores
53 - Enclosed Mall
58 - Business and
Residential
59 - Office Use
60 - Industrial Use
63 - Military Use
65 - Farm Use
00 - Other Mixed Use
Property Use None
Structures
131 Church, Place of Worship
161 Restaurant or Cafeteria
162 Bar/Tavern or Nightclub
213 Elementary School, Kindegarten
215 High School, Junior High
241 College, Adult Education
311 Nursing Home
331 Hospital
341 Clinic, Clinic-Type Infirmary
342 Doctor/Dentist Office
361 Prison or Jail, Not Juvenile
419 1- or 2-Family Dwelling
429 MultiFamily Dwelling
439 Rooming/Boarding House
449 Commerical Hotel or Motel
459 Residential, Board and Care
464 Dormitory/Barracks
519 Food and Beverage Sales
539 Household Goods, Sales, Repairs
571 Gas or Service Station
579 Motor Vehicle/Boat Sales/Repairs
599 Business Office
615 Electric-Generating Plant
629 Laboratory/Science Laboratory
700 Manufacturing Plant
819 Livestock/Poultry Storage (Barn)
882 Non-Residential Parking Garage
891 Warehouse
Outside
124 Playground or Park
655 Crops or Orchard
669 Forest (Timberland)
807 Outdoor Storage Area
919 Dump or Sanitary Landfill
931 Open Land or Field
936 Vacant Lot
938 Graded/Cared for Plot of Land
946 Lake, River, Stream
951 Railroad Right-of-Way
960 Other Street
961 Highway/Divided Highway
962 Residential Street/Driveway
981 Construction Site
984 Industrial Plant Yard
Property Use:
Description
Look up and enter a Property Use code and
description only if you have NOT checked a
Property Use box.
Owner
Local Option Person/Entity Type Business Name (if applicable)Phone Number
Mr., Ms., Mrs.First Name MI Last Name Suffix
Number Prefix Street or Highway Street Type Suffix
Post Office Box Apt./Suite/Room City
State Zip Code
F G1 G2
H1
H2
H3 I
J
K2
Page 2 of 8
Remarks:
E3 arrived at scene to find a 2 story single family town home/condo with water flowing out of garage on Charlie side of the
structure. No fire, light residual smoke throughout the structure mainly on division 2 floor. Tenants stated they were cooking
french fry's using a grease fryer and were next door visiting family, when they heard smoke detectors. Tenants returned to
involved unit to witness two activated sprinkler heads w/ no fire. Grease fire burned vertical which caused damage to
microwave and upper cabinets. Sprinkler in kitchen and living room were activated. E3 crew, along with T1 crew located and
shut down sprinkler system and drain. E3 crew also isolated and shut down appropriate electrical breakers at panel. Light
ventilation was performed to clear upstairs. Vertical ceiling drywall above stove was opened and checked for extension
which was all clear. Crews removed all 2" of water located in the down stairs area (wood/tile floors.) Tenants were renting the
unit for the holidays via Airbnb. Tenants tried to contact home owner numerous times while E3 was at scene with no luck.
Structure was turned over to tenants with no further hazards.
Authorization
14845 Barrett, Richard Fire Captain 12/31/2024
Officer In Charge ID Signature Position or Rank Assignment Date
14845 Barrett, Richard Fire Captain 12/31/2024
Member Making Report
ID
Signature Position or Rank Assignment Date
L
M
Page 3 of 8
NFIRS-2 Fire
40060 CA 12 25 2024 Fire Station
3 (FS3)
24-07396 0
FDID State Month Day Year Station Number Exposure
Property Details
B1 Not Residential
Estimated number of residential living units in the building
of origin whether or not all units became involved
B2 Buildings Not Involved
Number of buildings involved
B3 None Less than 1 acre
Acres burned (outside fires)
On-Site Materials
Or Products
On-Site Materials
Storage Use
Ignition
D1 24-Cooking area, kitchen
Area of Fire Origin
D2 00-Heat source: other
Heat Source
D3 20-Furniture, utensils, other
Item First Ignited
D4
31-Fat, grease, butter, margarine,
lard
Type of Material First Ignited
Cause of Ignition
1 - Intentional
2 - Unintentional
3 - Failure of Equipment or Heat
Source
4 - Act of Nature
5 - Cause Under Investigation
U - Cause Undetermined After
Investigation
Factors Contributing to Ignition
10-Misuse of material or product, other
Factor Contributing to Ignition
Human Factors Contributing to
Ignition
Check all applicable boxes
None
1 - Asleep
2 - Possibly impaired by alcohol or
drugs
3 - Unattended person
4 - Possibly Mentally Disabled
5 - Physically Disabled
6 - Multiple Persons Involved
7 - Age Was A Factor
Estimated Age of
Person Involved
Male Female
Equipment Involved In Ignition
Equipment Involved
Brand
Model
Serial #
Year
Equipment Power Source
Equipment Power Source
Equipment Portability
1 - Portable
2 - Stationary
Portable equipment normally can be moved by one or two
persons.
Fire Suppression Factors
A
B C
D E1
E2
E3
F1 F2
F3
G
Page 4 of 8
Mobile Property Involved
1 - Not involved in ignition, but burned
2 - Involved in ignition, but did not burn
3 - Involved in ignition and burned
None
Mobile Property Type and Make
Mobile Property Type
Mobile Property Make
Local Use
Pre-Fire Plan Available
Arson Report Attached
Police Report Attached
Coroner Report Attached
Other Reports Attached
Mobile Property Model Year
State License Plate Number VIN
_________________________
_________________________
_________________________
_________________________
_________________________
_________________________
H1 H2
Page 5 of 8
NFIRS-9 Apparatus or Resources
40060 CA 12 25 2024 Fire Station
3 (FS3)
24-07396 0
FDID State Month Day Year Station Number Exposure
B
Apparatus/Resource Dates/Times Sent
Number
of People Apparatus Use Actions Taken
ID:E3
Type:11-Engine
Dispatch:12/25/2024 21:35
Arrival:12/25/2024 21:41
Clear:12/25/2024 22:39
Sent 3 Suppression
EMS
Other
12-Salvage & overhaul
ID:E4
Type:11-Engine
Dispatch:12/25/2024 21:35
Arrival:
Clear:12/25/2024 21:37
Sent 3 Suppression
EMS
Other
93-Cancelled en route
ID:T1
Type:12-Truck or aerial
Dispatch:
Arrival:12/25/2024 21:43
Clear:12/25/2024 22:12
Sent 4 Suppression
EMS
Other
12-Salvage & overhaul
A
Page 6 of 8
NFIRS-10 Personnel
40060 CA 12 25 2024 Fire Station
3 (FS3)
24-07396 0
FDID State Month Day Year Station Number Exposure
B
Apparatus/Resource Dates/Times Sent
Number
of People Apparatus Use Actions Taken
ID:E3
Type:11-Engine
Dispatch:12/25/2024 21:35
Arrival:12/25/2024 21:41
Clear:12/25/2024 22:39
Sent 3 Suppression
EMS
Other
12-Salvage & overhaul
Personnel ID Name Rank Role Attend Actions Taken
99188 Thoele, Brendan Engineer
14845 Barrett, Richard Captain
99161 Hutslar, Dane Firefighter
ID:E4
Type:11-Engine
Dispatch:12/25/2024 21:35
Arrival:
Clear:12/25/2024 21:37
Sent 3 Suppression
EMS
Other
93-Cancelled en route
Personnel ID Name Rank Role Attend Actions Taken
50050 Jeckell, Matthew Captain
100077 Greenelsh, Nathaniel Firefighter
99187 Sensenbach, Mickey Engineer
ID:T1
Type:12-Truck or aerial
Dispatch:
Arrival:12/25/2024 21:43
Clear:12/25/2024 22:12
Sent 4 Suppression
EMS
Other
12-Salvage & overhaul
Personnel ID Name Rank Role Attend Actions Taken
61580 Mason, Ryan Engineer
46543 Hicks, Judson Firefighter
88690 Vasquez, Mark Captain
90841 Weis, Trevor Engineer
A
Page 7 of 8
NFIRS-1S Supplemental
40060 CA 12 25 2024 Fire Station
3 (FS3)
24-07396 0
FDID State Month Day Year Station Number Exposure
Primary Narrative:
E3 arrived at scene to find a 2 story single family town home/condo with water flowing out of garage on Charlie side of the
structure. No fire, light residual smoke throughout the structure mainly on division 2 floor. Tenants stated they were cooking
french fry's using a grease fryer and were next door visiting family, when they heard smoke detectors. Tenants returned to
involved unit to witness two activated sprinkler heads w/ no fire. Grease fire burned vertical which caused damage to
microwave and upper cabinets. Sprinkler in kitchen and living room were activated. E3 crew, along with T1 crew located and
shut down sprinkler system and drain. E3 crew also isolated and shut down appropriate electrical breakers at panel. Light
ventilation was performed to clear upstairs. Vertical ceiling drywall above stove was opened and checked for extension
which was all clear. Crews removed all 2" of water located in the down stairs area (wood/tile floors.) Tenants were renting the
unit for the holidays via Airbnb. Tenants tried to contact home owner numerous times while E3 was at scene with no luck.
Structure was turned over to tenants with no further hazards.
Apparatus Narrative for E3:
Crew doned proper structure fire PPE
A
Page 8 of 8