HomeMy WebLinkAbout3055 Garibaldi Ave Fire ReportNFIRS-1 Basic 40060 CA 12 25 2024 Fire Station 3 (FS3) 24-07396 0 FDID State Month Day Year Station Number Exposure Location Type Census tract: Street Address Intersection In Front Of Rear Of Adjacent To Directions US National Grid 3057 GARIBALDI Number Prefix Street or Highway Street Type Suffix San Luis Obispo CA 93401 Apt./Suite/Room City State Zip Code Cross Street Incident Type 100-Fire, other Aid Given Or Received 1 Mutual Aid Received 2 Auto. Aid Received 3 Mutual Aid Given 4 Auto. Aid Given 5 Other Aid Given None Their FDID Their State Their Incident Number Dates and Times Alarm 12 25 2024 21:35 Arrival 12 25 2024 21:41 Controlled 12 25 2024 21:42 Last Unit Cleared 12 25 2024 22:39 Shifts and Alarms C NA FZ3 Shift or Platoon Alarms District Special Studies 9244 4 - Unknown ID#Value A B C D E1 E2 E3 Page 1 of 8 Actions Taken 12-Salvage & overhaul Primary Action Taken Resources Apparatus or Personnel Module is used. Apparatus Personnel Suppression 3 10 EMS 0 0 Other 0 0 Resource counts include aid received resources. Estimated Dollar Losses and Values Losses:Required for all fires if known. Optional for all non-fires. None Property:$ Contents:$ Pre-Incident Values: Optional None Property:$ 800,000.00 Contents:$ Completed Modules 2 - Fire 3 - Structure Fire 4 - Civilian Fire Cas. 5 - Fire Service Cas. 6 - EMS 7 - HazMat 8 - Wildland Fire 9 - Apparatus 10 - Personnel 11 - Arson Casualties None Deaths Injuries Fire Service 0 0 Civilian 0 0 Detector Required for Confined Fires 1 - Detector Alerted Occupants 2 - Detector Did Not Alert Them 3 - Unknown Hazardous Materials Release 1 - Natural Gas 2 - Propane Gas 3 - Gasoline 4 - Kerosene 5 - Diesel Fuel / Fuel Oil 6 - Household Solvents 7 - Motor Oil 8 - Paint 0 - Other None Mixed Use Property Not Mixed 10 - Assembly Use 20 - Education Use 33 - Medical Use 40 - Residential Use 51 - Row Of Stores 53 - Enclosed Mall 58 - Business and Residential 59 - Office Use 60 - Industrial Use 63 - Military Use 65 - Farm Use 00 - Other Mixed Use Property Use None Structures 131 Church, Place of Worship 161 Restaurant or Cafeteria 162 Bar/Tavern or Nightclub 213 Elementary School, Kindegarten 215 High School, Junior High 241 College, Adult Education 311 Nursing Home 331 Hospital 341 Clinic, Clinic-Type Infirmary 342 Doctor/Dentist Office 361 Prison or Jail, Not Juvenile 419 1- or 2-Family Dwelling 429 MultiFamily Dwelling 439 Rooming/Boarding House 449 Commerical Hotel or Motel 459 Residential, Board and Care 464 Dormitory/Barracks 519 Food and Beverage Sales 539 Household Goods, Sales, Repairs 571 Gas or Service Station 579 Motor Vehicle/Boat Sales/Repairs 599 Business Office 615 Electric-Generating Plant 629 Laboratory/Science Laboratory 700 Manufacturing Plant 819 Livestock/Poultry Storage (Barn) 882 Non-Residential Parking Garage 891 Warehouse Outside 124 Playground or Park 655 Crops or Orchard 669 Forest (Timberland) 807 Outdoor Storage Area 919 Dump or Sanitary Landfill 931 Open Land or Field 936 Vacant Lot 938 Graded/Cared for Plot of Land 946 Lake, River, Stream 951 Railroad Right-of-Way 960 Other Street 961 Highway/Divided Highway 962 Residential Street/Driveway 981 Construction Site 984 Industrial Plant Yard Property Use: Description Look up and enter a Property Use code and description only if you have NOT checked a Property Use box. Owner Local Option Person/Entity Type Business Name (if applicable)Phone Number Mr., Ms., Mrs.First Name MI Last Name Suffix Number Prefix Street or Highway Street Type Suffix Post Office Box Apt./Suite/Room City State Zip Code F G1 G2 H1 H2 H3 I J K2 Page 2 of 8 Remarks: E3 arrived at scene to find a 2 story single family town home/condo with water flowing out of garage on Charlie side of the structure. No fire, light residual smoke throughout the structure mainly on division 2 floor. Tenants stated they were cooking french fry's using a grease fryer and were next door visiting family, when they heard smoke detectors. Tenants returned to involved unit to witness two activated sprinkler heads w/ no fire. Grease fire burned vertical which caused damage to microwave and upper cabinets. Sprinkler in kitchen and living room were activated. E3 crew, along with T1 crew located and shut down sprinkler system and drain. E3 crew also isolated and shut down appropriate electrical breakers at panel. Light ventilation was performed to clear upstairs. Vertical ceiling drywall above stove was opened and checked for extension which was all clear. Crews removed all 2" of water located in the down stairs area (wood/tile floors.) Tenants were renting the unit for the holidays via Airbnb. Tenants tried to contact home owner numerous times while E3 was at scene with no luck. Structure was turned over to tenants with no further hazards. Authorization 14845 Barrett, Richard Fire Captain 12/31/2024 Officer In Charge ID Signature Position or Rank Assignment Date 14845 Barrett, Richard Fire Captain 12/31/2024 Member Making Report ID Signature Position or Rank Assignment Date L M Page 3 of 8 NFIRS-2 Fire 40060 CA 12 25 2024 Fire Station 3 (FS3) 24-07396 0 FDID State Month Day Year Station Number Exposure Property Details B1 Not Residential Estimated number of residential living units in the building of origin whether or not all units became involved B2 Buildings Not Involved Number of buildings involved B3 None Less than 1 acre Acres burned (outside fires) On-Site Materials Or Products On-Site Materials Storage Use Ignition D1 24-Cooking area, kitchen Area of Fire Origin D2 00-Heat source: other Heat Source D3 20-Furniture, utensils, other Item First Ignited D4 31-Fat, grease, butter, margarine, lard Type of Material First Ignited Cause of Ignition 1 - Intentional 2 - Unintentional 3 - Failure of Equipment or Heat Source 4 - Act of Nature 5 - Cause Under Investigation U - Cause Undetermined After Investigation Factors Contributing to Ignition 10-Misuse of material or product, other Factor Contributing to Ignition Human Factors Contributing to Ignition Check all applicable boxes None 1 - Asleep 2 - Possibly impaired by alcohol or drugs 3 - Unattended person 4 - Possibly Mentally Disabled 5 - Physically Disabled 6 - Multiple Persons Involved 7 - Age Was A Factor Estimated Age of Person Involved Male Female Equipment Involved In Ignition Equipment Involved Brand Model Serial # Year Equipment Power Source Equipment Power Source Equipment Portability 1 - Portable 2 - Stationary Portable equipment normally can be moved by one or two persons. Fire Suppression Factors A B C D E1 E2 E3 F1 F2 F3 G Page 4 of 8 Mobile Property Involved 1 - Not involved in ignition, but burned 2 - Involved in ignition, but did not burn 3 - Involved in ignition and burned None Mobile Property Type and Make Mobile Property Type Mobile Property Make Local Use Pre-Fire Plan Available Arson Report Attached Police Report Attached Coroner Report Attached Other Reports Attached Mobile Property Model Year State License Plate Number VIN _________________________ _________________________ _________________________ _________________________ _________________________ _________________________ H1 H2 Page 5 of 8 NFIRS-9 Apparatus or Resources 40060 CA 12 25 2024 Fire Station 3 (FS3) 24-07396 0 FDID State Month Day Year Station Number Exposure B Apparatus/Resource Dates/Times Sent Number of People Apparatus Use Actions Taken ID:E3 Type:11-Engine Dispatch:12/25/2024 21:35 Arrival:12/25/2024 21:41 Clear:12/25/2024 22:39 Sent 3 Suppression EMS Other 12-Salvage & overhaul ID:E4 Type:11-Engine Dispatch:12/25/2024 21:35 Arrival: Clear:12/25/2024 21:37 Sent 3 Suppression EMS Other 93-Cancelled en route ID:T1 Type:12-Truck or aerial Dispatch: Arrival:12/25/2024 21:43 Clear:12/25/2024 22:12 Sent 4 Suppression EMS Other 12-Salvage & overhaul A Page 6 of 8 NFIRS-10 Personnel 40060 CA 12 25 2024 Fire Station 3 (FS3) 24-07396 0 FDID State Month Day Year Station Number Exposure B Apparatus/Resource Dates/Times Sent Number of People Apparatus Use Actions Taken ID:E3 Type:11-Engine Dispatch:12/25/2024 21:35 Arrival:12/25/2024 21:41 Clear:12/25/2024 22:39 Sent 3 Suppression EMS Other 12-Salvage & overhaul Personnel ID Name Rank Role Attend Actions Taken 99188 Thoele, Brendan Engineer 14845 Barrett, Richard Captain 99161 Hutslar, Dane Firefighter ID:E4 Type:11-Engine Dispatch:12/25/2024 21:35 Arrival: Clear:12/25/2024 21:37 Sent 3 Suppression EMS Other 93-Cancelled en route Personnel ID Name Rank Role Attend Actions Taken 50050 Jeckell, Matthew Captain 100077 Greenelsh, Nathaniel Firefighter 99187 Sensenbach, Mickey Engineer ID:T1 Type:12-Truck or aerial Dispatch: Arrival:12/25/2024 21:43 Clear:12/25/2024 22:12 Sent 4 Suppression EMS Other 12-Salvage & overhaul Personnel ID Name Rank Role Attend Actions Taken 61580 Mason, Ryan Engineer 46543 Hicks, Judson Firefighter 88690 Vasquez, Mark Captain 90841 Weis, Trevor Engineer A Page 7 of 8 NFIRS-1S Supplemental 40060 CA 12 25 2024 Fire Station 3 (FS3) 24-07396 0 FDID State Month Day Year Station Number Exposure Primary Narrative: E3 arrived at scene to find a 2 story single family town home/condo with water flowing out of garage on Charlie side of the structure. No fire, light residual smoke throughout the structure mainly on division 2 floor. Tenants stated they were cooking french fry's using a grease fryer and were next door visiting family, when they heard smoke detectors. Tenants returned to involved unit to witness two activated sprinkler heads w/ no fire. Grease fire burned vertical which caused damage to microwave and upper cabinets. Sprinkler in kitchen and living room were activated. E3 crew, along with T1 crew located and shut down sprinkler system and drain. E3 crew also isolated and shut down appropriate electrical breakers at panel. Light ventilation was performed to clear upstairs. Vertical ceiling drywall above stove was opened and checked for extension which was all clear. Crews removed all 2" of water located in the down stairs area (wood/tile floors.) Tenants were renting the unit for the holidays via Airbnb. Tenants tried to contact home owner numerous times while E3 was at scene with no luck. Structure was turned over to tenants with no further hazards. Apparatus Narrative for E3: Crew doned proper structure fire PPE A Page 8 of 8