Loading...
HomeMy WebLinkAboutProject PlansS A C R A M E N T O D R I V E EXISTING BUILDING 200.50 FF (APPROXIMATE) 200.60 - 200.43 FF RANGE RIGHT OF WAY RIGHT OF WAY PROPERTY LINE PROPERTY LINE S A C R A M E N T O D R I V E ENCROACHMENT EASEMENT OPEN SPACE EASEMENT OPEN SPACE EASEMENT 10 . 0 0 ' PG E EA S E M E N T V I A E S T E B A N A C A C I A C R E E K 60.0' R I G H T O F W A Y 8.1' 21.8' 20.4' 9.7' /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// NO PARKING NO PA R K I N G COMPACT COMPACT COMPACT COMPACT COMPACT COMPACTCOMPACTCOMPACT WM IRR 1 1 1 1 2 TYP 2 TYP 2 TYP 2 TYP 2 TYP 2 TYP 2 TYP 3 3 3 3 3 4 4 4 4 4 4 5 TYP 5 TYP 5 TYP 5 TYP 6 7 7 7 777 7 8 8 8 9 9 9 9 9 10 10 10 21 21 21 21 21 21 22 22 22 22 22 22 23 23 23 23 23 23 24 24 25 5.00' ASPHA L T SIDEW A L K 26 27 26 26 28 28 28 28 28 60 . 1 0 ' F U L L B A Y D I M E N S I O N 2. 5 0 ' O V E R H A N G 18 . 4 0 ' S T A L L 2. 5 0 ' O V E R H A N G 18 . 4 0 ' S T A L L 60.10' FULL BAY DIMENSION 2.50' OVERHANG 18.40' STALL 2.50' OVERHANG 18.40' STALL 18.00'9. 0 0 ' 5. 0 0 ' 9. 0 0 ' 57 . 7 0 ' B A Y D I M E N S I O N A T C O M P A C T P A R K I N G 2. 5 0 ' O V E R H A N G 18 . 4 0 ' S T A L L 2. 5 0 ' O V E R H A N G 16 . 0 0 ' S T A L L 60 . 1 0 ' F U L L B A Y D I M E N S I O N 2. 5 0 ' O V E R H A N G 18 . 4 0 ' S T A L L 2. 5 0 ' O V E R H A N G 18 . 4 0 ' S T A L L 9.00'8.00'9.00' 18 . 0 0 ' 29 29 29 29 31 31 TYPTYP 31 TYP 32 32 33 33 33 34 TYP 34 TYP 34 TYP 34 TYP 30 30 30 30 35 35 35 35 35 35 36 36 36 36 ADD "RIGHT TURN ONLY" TO EXISTING SIGN 22 34 TYP 34 TYP 37 37 2 0 . 0 0 ' 20.00' 2 0 . 0 0 ' 38 38 38 SL O C L A S S I C A L A C A D E M Y BR O A D S T R E E T C A M P U S PR O J E C T N A M E : PL A N S P R E P A R E D F O R : PR O J E C T L O C A T I O N : SL O C L A S S I C A L A C A D E M Y 16 5 G R A N D A V E SA N L U I S O B I S P O , C A 9 3 4 0 5 34 5 0 B R O A D S T SA N L U I S O B I S P O , C A 9 3 4 0 1 AP N : 0 5 3 - 2 2 1 - 0 3 5 ENGINEER OF RECORD: REVISIONS: CDS JOB #: SCALE: 24-078 AS SHOWN DATE:March 28, 2025 PREPARED BY:MRS REVIEWED BY:MRS z: \ S h a r e d \ C D S D a t a \ a c t i v e j o b s \ 2 4 - 0 7 8 s l o c l a s s i c a l a c a d e m y \ _ P r o j e c t \ 2 _ P r e l i m _ E n t i t l e m e n t s \ C 1 - P r e l i m S i t e P l a n . d w g , Ma r c h 2 8 , 2 0 2 5 A B C D E F G H I J K L M N O A B C D E F G H I J K L M N O 2 1 3 4 5 6 7 8 9 10 11 12 CI V I L E N G I N E E R I N G P L A N N I N G P E R M I T T I N G C IV I L DES I G N STU D I O P. O . B o x 1 9 9 | C a m b r i a | C A 9 3 4 2 8 80 5 . 7 0 6 . 0 4 0 1 w w w . c i v i l - s t u d i o . c o m P L A N R E V I E W S E T N O T F O R C O N S T R U C T I O N EEN I No . 7 4 7 3 6 TS C TAE FO I GE R AI O F I L A C L I V N R R E R P S D ERET F O NO I LA GNE ISS M O N T E R S O T O SHEET XX OF 3 SHEETS CONSTRUCTION NOTES LEGEND 21 PROPOSED ASPHALT OR ASPHALT GRIND AND OVERLAY 22 PROPOSED CONCRETE FLATWORK 23 PROPOSED CONCRETE CURB 24 PROPOSED REMOVAL OF DRIVEWAYS AND CONSTRUCTION OF PUBLIC CURB, GUTTER, AND SIDEWALK PER CITY OF SAN LUIS OBISPO STANDARDS 25 PROPOSED PUBLIC ASPHALT SIDEWALK TO CONNECT AS SHOWN FROM PUBLIC ROAD ADA RAMP AT EASTERN CORNER OF SITE, EXTENDING TO EXISTING SIDEWALK APPROXIMATELY 200' TO THE SOUTH (NOT SHOWN) 26 STANDARD ACCESSIBLE STALL WITH STRIPING AND SIGNAGE. PAVEMENT MAXIMUM SLOPE IN ANY DIRECTION SHALL NOT EXCEED 2% 27 VAN ACCESSIBLE STALL WITH STRIPING AND VAN ACCESSIBLE SIGNAGE. PAVEMENT MAXIMUM SLOPE IN ANY DIRECTION SHALL NOT EXCEED 2% 28 DETECTABLE WARNING SURFACE (TRUNCATED DOMES) 29 PROPOSED PARKING BAY DIMENSIONS IN COMPLIANCE WITH THE CITY OF SAN LUIS OBISPO PARKING STANDARDS 2230 - 2240 30 PROPOSED RETAINING WALL 31 PROPOSED 4" WIDE WHITE PARKING STRIPE PER CITY REQUIREMENTS 32 PROPOSED STAIRS (WOOD OR CONCRETE) 33 PROPOSED DECK OVER EXISTING STORM DRAINAGE BASINS. BOTTOM OF DECK SHALL BE LOCATAED 6" MIN ABOVE SPILLWAY ELEVATION 34 PROPOSED LANDSCAPE FEATURE 35 PROPOSED FENCE WITH GATES 36 EXISTING BUILDING 37 PROPOSED DECOMPOSED GRANITE 38 PROPOSED DECK. FOUNDATION SHALL BE OUTSIDE OF OPEN SPACE EASEMENT ASPHALT CONCRETE IN PEDESTRIAN AREA DETECTABLE WARNING SURFACE28 22 21 20 10 015 SCALE: 1" = 20' 20 40 C1 PRELIMINARY CIVIL SITE PLAN 1 EXISTING CONDITIONS NOTES 1 EXISTING ASPHALT PATH, PROTECT IN PLACE 2 EXISTING TREE, PROTECT IN PLACE 3 EXISTING PARKING LOT ASPHALT, PROTECT IN PLACE 4 EXISTING CONCRETE CURB, PROTECT IN PLACE 5 EXISTING PARKING LOT STRIPING, PROTECT IN PLACE 6 EXISTING TRASH ENCLOSURE, PROTECT IN PLACE 7 EXISTING SPEED BUMP OR SPEED TABLE, PROTECT IN PLACE 8 ACACIA CREEK FLOWLINE, APPROXIMATE LOCATION 9 LOCATION OF TOP OF CREEK BANK AND RIPARIAN VEGETATION 10 LOCATION OF EXISTING 20' CREEK SETBACK DECK3338 S A C R A M E N T O D R I V E EXISTING BUILDING 200.50 FF (APPROXIMATE) 200.60 - 200.43 FF RANGE RIGHT OF WAY RIGHT OF WAY PROPERTY LINE PROPERTY LINE S A C R A M E N T O D R I V E V I A E S T E B A N A C A C I A C R E E K 60.0' R I G H T O F W A Y 8.1' 21.8' 20.4' 9.7' /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// NO PARKING NO PA R K I N G COMPACT COMPACT COMPACT COMPACT COMPACT COMPACTCOMPACTCOMPACT WM IRR 200.51 FS (199) (19 9 ) ( 1 9 7 ) (1 9 8 ) (1 9 9 ) (199) (200) ( 1 9 8 ) ( 1 9 9 ) (2 0 1 ) (2 0 2 ) ( 2 0 3 ) (2 0 4 ) ( 2 0 4 ) ( 2 0 5 ) (19 6 ) (19 7 ) (1 9 8 ) (1 9 9 ) (19 5 ) (19 6 ) (19 7 ) (19 8 ) (19 9 ) (20 1 ) ( 2 0 2 ) ( 2 0 3 ) ( 2 0 0 ) (2 0 0 ) (199) ( 2 0 1 ) ( 2 0 2 ) (202) 199.4 EG 199.4 EG (199.6) EG (199.2) EG (199.3) EG (199.4) EG (199.4) EG (199.3) EG (199.4) EG (199.4) EG (199.3) EG (199.3) EG (199.3) EG (199.5) EG (199.5) EG (199.4) EG (199.4) EG (199.4) EG (199.5) EG (199.6) EG (201.3) EG (199.4) EG (198.7) EG (198.4) EG (198.6) EG (198.7) EG (198.8) EG (198.6) EG (198.5) EG (198.5) EG (198.6) EG (198.7) EG (198.9) EG (198.8) EG (198.7) EG (198.5) EG (198.3) EG (198.6) EG (198.9) EG (199.3) EG (199.8) EG (200.7) EG (199.3) EG 200.10 TC 199.60 FS 200.2 EG 200.10 TC 199.60 FS 200.00 TC 199.50 FS 200.00 TC 199.50 FS 200.08 TC 199.58 FS 200.08 TC 199.58 FS 200.56 FS (200.56) FF (200.49) FF (200.49) FF (200.50) FF (200.50) FF (200.51) FF (200.49) FF (200.51) FF (200.49) FF (200.60) FF (200.58) FF (200.43) FF (200.49) FF (200.51) FF (200.45) FF (200.48) FF (200.46) FF 199.3 EG 199.3 EG 199.60 FS 199.70 FS 200.20 FS 200.10 TC 199.60 FS 197.5 EG 200.00 FS 199.70 FS 5% M A X 5 % M A X 200.10 TC 199.60 FS 200.90 TC 200.40 FS 201.90 TC 201.40 FS 200.35 FS 200.70 FS200.25 FS 200.10 TC 199.60 FS 201.58 FS (203.2) EG (204.3) EG 8 . 3 % M A X 200.36 FS 200.33 FS 200.36 FS 201.20 FS 205.00 FS 205.00 FS 200.87 FS200.87 FS 200.00 FS 199.70 FS 200.50 FS 5% MAX 5% M A X 200.58 FS 200.60 FS 199.00 TG 199.80 FS 200.0 FG 200.00 FS 201.0 FG 202.1 FG 203.1 FG 200.40 FS 200.50 FS (200.8) EG 200.55 FS 201.20 TC 200.70 FS 200.20 FS 3 STEPS AT 6.5" 200.65 FS 199.95 FS 200.80 TC 200.30 FS 5% M A X 5% M A X SL O C L A S S I C A L A C A D E M Y BR O A D S T R E E T C A M P U S PR O J E C T N A M E : PL A N S P R E P A R E D F O R : PR O J E C T L O C A T I O N : SL O C L A S S I C A L A C A D E M Y 16 5 G R A N D A V E SA N L U I S O B I S P O , C A 9 3 4 0 5 34 5 0 B R O A D S T SA N L U I S O B I S P O , C A 9 3 4 0 1 AP N : 0 5 3 - 2 2 1 - 0 3 5 ENGINEER OF RECORD: REVISIONS: CDS JOB #: SCALE: 24-078 AS SHOWN DATE:March 28, 2025 PREPARED BY:MRS REVIEWED BY:MRS z: \ S h a r e d \ C D S D a t a \ a c t i v e j o b s \ 2 4 - 0 7 8 s l o c l a s s i c a l a c a d e m y \ _ P r o j e c t \ 2 _ P r e l i m _ E n t i t l e m e n t s \ C 2 - P r e l i m G r a d i n g P l a n . d w g , Ma r c h 2 8 , 2 0 2 5 A B C D E F G H I J K L M N O A B C D E F G H I J K L M N O 2 1 3 4 5 6 7 8 9 10 11 12 CI V I L E N G I N E E R I N G P L A N N I N G P E R M I T T I N G C IV I L DES I G N STU D I O P. O . B o x 1 9 9 | C a m b r i a | C A 9 3 4 2 8 80 5 . 7 0 6 . 0 4 0 1 w w w . c i v i l - s t u d i o . c o m P L A N R E V I E W S E T N O T F O R C O N S T R U C T I O N EEN I No . 7 4 7 3 6 TS C TAE FO I GE R AI O F I L A C L I V N R R E R P S D ERET F O NO I LA GNE ISS M O N T E R S O T O SHEET XX OF 3 SHEETS 20 10 015 SCALE: 1" = 20' 20 40 C2 PRELIMINARY GRADING PLAN 2 NOTE: ALL PROPOSED CONCRETE WALKWAYS SHALL BE CONSTRUCTED WITH ACCESSIBLE SLOPES. 1.5% CROSS SLOPE AND 4.5% MAXIMUM RUNNING SLOPE. NOTE: CONCRETE POURED ADJACENT TO BUILDING DOORS SHALL PROVIDE AN ACCESSIBLE FLUSH TRANSITION FROM EXTERIOR FLATWORK TO THE BUILDING FINISHED FLOOR ELEVATION. 199.38 RIM 1 8 " H D P E S T O R M D R A I N S A C R A M E N T O D R I V E EXISTING BUILDING 200.50 FF (APPROXIMATE) 200.60 - 200.43 FF RANGE RIGHT OF WAY RIGHT OF WAY PROPERTY LINE PROPERTY LINE S A C R A M E N T O D R I V E ENCROACHMENT EASEMENT OPEN SPACE EASEMENT OPEN SPACE EASEMENT 10 . 0 0 ' PG E EA S E M E N T V I A E S T E B A N A C A C I A C R E E K 196.87 RIM 18" HDPE STORM DRAIN 18" HDPE STORM DRAIN 18" HD P E S T O R M D R A I N 18" HDPE S T O R M D R A I N 12 " H D P E S T O R M D R A I N 18 " H D P E S T O R M D R A I N 6" S D R 3 5 S S L I N E 6" SDR 3 5 P V C S S L I N E 1 2 " C A S T I R O N C E M E N T L I N E D W A T E R M A I N 1 0 " P V C S S M A I N 8 " S E W E R M A I N 6" FIR E W A T E R S E R V I C E L A T E R A L 60.0' R I G H T O F W A Y 8.1' 21.8' 20.4' 9.7' S D S D SD SD SD SD SD SD SD SD SD SD SD SD SD SD /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// W L W L W L W L W L W L W L W L W L W L W L W L W L W L W L W L WL WL WL SD SD G G G G G G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S SS SS G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SD SD SD SD SD SD SD SD SD WL WL WL WLWL WL SS SS SS SS SS SS SS SD SD SD SD SD SD S D WLS D S D S D SD SD SD SD WLWL WM IRR WL WL 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 43 43 43 51 51 51 52 52 53 51 41 61 62 62 63 6465 81 81 81 82 83 8383 8383 83 83 54 66 66 81 81 SL O C L A S S I C A L A C A D E M Y BR O A D S T R E E T C A M P U S PR O J E C T N A M E : PL A N S P R E P A R E D F O R : PR O J E C T L O C A T I O N : SL O C L A S S I C A L A C A D E M Y 16 5 G R A N D A V E SA N L U I S O B I S P O , C A 9 3 4 0 5 34 5 0 B R O A D S T SA N L U I S O B I S P O , C A 9 3 4 0 1 AP N : 0 5 3 - 2 2 1 - 0 3 5 ENGINEER OF RECORD: REVISIONS: CDS JOB #: SCALE: 24-078 AS SHOWN DATE:March 28, 2025 PREPARED BY:MRS REVIEWED BY:MRS z: \ S h a r e d \ C D S D a t a \ a c t i v e j o b s \ 2 4 - 0 7 8 s l o c l a s s i c a l a c a d e m y \ _ P r o j e c t \ 2 _ P r e l i m _ E n t i t l e m e n t s \ C 3 - P r e l i m U t i l i t y P l a n . d w g , Ma r c h 2 8 , 2 0 2 5 A B C D E F G H I J K L M N O A B C D E F G H I J K L M N O 2 1 3 4 5 6 7 8 9 10 11 12 CI V I L E N G I N E E R I N G P L A N N I N G P E R M I T T I N G C IV I L DES I G N STU D I O P. O . B o x 1 9 9 | C a m b r i a | C A 9 3 4 2 8 80 5 . 7 0 6 . 0 4 0 1 w w w . c i v i l - s t u d i o . c o m P L A N R E V I E W S E T N O T F O R C O N S T R U C T I O N EEN I No . 7 4 7 3 6 TS C TAE FO I GE R AI O F I L A C L I V N R R E R P S D ERET F O NO I LA GNE ISS M O N T E R S O T O SHEET XX OF 3 SHEETS 20 10 015 SCALE: 1" = 20' 20 40 C3 PRELIMINARY UTILITY PLAN 3 NOTE: STORM DRAINAGE PIPING AND CATCH BASINS SHOWN ON THIS PLAN ARE BASED ON A COMBINATION OF RECENT TOPOGRAPHIC SURVEY INFORMATION AS WELL AS RECORD INFORMATION FROM ORIGINAL BUILDING CONSTRUCTION PLANS. UTILITY CONSTRUCTION NOTES 41 EXISTING STORM DRAIN PIPE, PROTECT IN PLACE 42 EXISTING STORM DRAIN CATCH BASIN, ADJUST TO GRADE IF NECESSARY 43 LOCATION OF EXISTING STORMWATER BASIN, NO MODIFICATION PROPOSED. DECK ABOVE WILL NOT AFFECT STORAGE CAPACITY NOTES 44 TO 50 NOT USED 51 EXISTING SANITARY SEWER LINE - PROTECT IN PLACE 52 EXISTING SANITARY SEWER MANHOLE - PROTECT IN PLACE 53 EXISTING SANITARY SEWER CLEANOUT - PROTECT IN PLACE 54 PROPOSED GREASE INTERCEPTOR NOTE 55 TO 60 NOT USED 61 SIX EXISTING WATER LATERALS AND METERS - ABANDON LATERALS IN PLACE, REMOVE METERS AND RECONSTRUCT SIDEWALK, CAP AT CORPORATION STOP. 62 EXISTING FIRE HYDRANT - PROTECT IN PLACE 63 PROPOSED COMMERCIAL WATER SERVICE, METER, AND BACKFLOW PREVENTION PER CITY STANDARDS 64 PROPOSED LANDSCAPE WATER SERVICE, METER, AND BACKFLOW PREVENTION (IRRIGATION POINT OF CONNECTION) PER CITY STANDARDS 65 EXISTING 6" DOUBLE CHECK DETECTOR WITH FIRE DEPARTMENT CONNECTION (FDC) 66 PROPOSED PUBLIC HYDRANT ASSEMBLY TO BE INSTALLED NOTES 67 TO 80 NOT USED 81 PROPOSED MECHANICAL EQUIPMENT 82 EXISTING GAS METERS, PROTECT IN PLACE 83 EXISTING SITE LIGHT, PROTECT IN PLACE EXISTING SITE STORMWATER CONTROL NARRATIVE: THE EXISTING DEVELOPMENT PROJECT WAS CONSTRUCTED IN APPROXIMATELY 1998. DRAINAGE FOR THE PROPERTY IS COLLECTED INTO THREE SURFACE STORAGE BASINS AND DRAINAGE INLETS IN THE PARKING LOT WHICH FLOW TO A JUNCTION BOX WITH ORIFICE PLATE TO MITIGATE PEAK FLOW DISCHARGE. PROPOSED STORMWATER CONTROL NARRATIVE: EXISTING DRAINAGE PATTERNS FOR THE PROPOSED DEVELOPMENT WILL NOT BE MODIFIED FROM THE EXISTING DEVELOPMENT. THE PROPOSED DEVELOPMENT WILL RESULT IN A REDUCTION OF IMPERVIOUS AREA FOR THE PROJECT SITE DUE TO THE REMOVAL OF THE PARKING LOT ON THE NORTH SIDE. THEREFORE, THE PROPOSED RECONSTRUCTION OF THE SITE WILL RESULT IN A REDUCTION IN STORMWATER RUNOFF. PROPOSED WATER DESIGN NARRATIVE: WATER SERVICE TO THE REMODELED BUILDING IS PROPOSED TO BE RECONSTRUCTED INTO ONE PROPERLY SIZED WATER METER. THERE ARE CURRENTLY 6 EXISTING WATER METERS FOR THE PROPERTY, WHICH WILL BE REMOVED WITH THIS PROJECT. PROPOSED WATER SERVICE FIXTURE UNITS TOTAL APPROXIMATELY 220 WSFU. THE PROPOSED WATER METER WILL BE PROPERLY SIZED TO ACCOMMODATE THE NEW DEMAND. PROPOSED FIRE DESIGN NARRATIVE: THE PROPERTY CURRENTLY HAS AN EXISTING 6" DOUBLE DETECTOR CHECK VALVE INSTALLED. NO MODIFICATION TO THIS SYSTEM IS PROPOSED AT THIS TIME. THE CITY WATER MAIN CAN PROVIDE 2500GPM WITH A RESIDUAL PRESSURE OF 79PSI PER WATER MODEL PROVIDED BY WALLACE GROUP. PROPOSED SEWER DESIGN NARRATIVE: THE PROPERTY CURRENTLY HAS AN EXISTING 6" SEWER LATERAL AND SEWER PIPE INSTALLED. NO MODIFICATION TO THIS SYSTEM IS PROPOSED AT THIS TIME. PROPOSED DRAINAGE FIXTURE UNITS TOTAL APPROXIMATELY 220 DFU. THEREFORE, PER CPC TABLE 702.1, A 6" SEWER LATERAL IS SUFFICIENT.