HomeMy WebLinkAboutCODE-000007-20251150 Laurel 2024-11-22 List of Corrections from FireFrom:Nelson, Trevor To:Mezzapesa, John Subject:Fwd: 1150 Laurel List of Corrections Date:Monday, December 9, 2024 10:06:40 AM Attachments:image001.png image002.png image003.png image004.png image005.png image006.png Get Outlook for iOS From: Hutchinson, Julianna <JHutchin@slocity.org> Sent: Friday, November 22, 2024 9:45:38 AM To: Chuck Braff <chuck@westpacinv.com> Cc: Loew, Michael <Mloew@slocity.org>; Nelson, Trevor <tnelson@slocity.org>; Beres, Jason <jberes@slocity.org>; Tuggle, Todd <ttuggle@slocity.org> Subject: 1150 Laurel List of Corrections Hi Chuck, Here is the rough list of general building fire and life safety violations found yesterday. Provide annual fire alarm, fire sprinkler, fire hydrant, and fire pump test reports. Fire sprinklers are considered deficient due to an incomplete system with unprotected, unsprinkered areas. The temporary fire pump has greatly exceeded the allowable number of days it was permitted for operation in lieu of a permanent fire pump. The sites underground fire line and permanent pump are required to be installed. All fire extinguishers in the building and units are due for their annual service and need updated tags. Remove dead trees around the property and prune back dead brush/limbs. Storage space for electrician company, Cal fire, etc. shall have clear exit paths through the storage and to the outside. Space is considered unsafe with unpermitted high piled storage and unclear pathways. Remove all storage in rated exit hallways and have any chemicals and hazardous materials stored in proper flame cabinets or in other approved areas. No propane storage inside. Chain and lock fire sprinkler riser valves in the open position where easily accessible to the public. Place sign on inactive backflow at entry to property indicating it is out of service so that first responders don’t connect to an inactive one.. Unblock fire hydrant at back of property and provide clear 26’ wide space in front of all onsite fire hydrants. Secure exterior combustibles/wood storage on site from public access and maintain stacks in accordance with section 315.4 of the 2022 California Fire Code. Cover exposed electrical wiring in occupied spaces and remove or safely secure wire tripping hazard in event space. Assembly occupancies, which are your event space and Bang the Drum, shall not have combustible hangings (such as non-fire treated curtains) except in accordance with section 807.2 of the 2022 California Fire Code. Building may have additional items for correction, and I will send you an inspection report when completed. Please let me know if you have any questions and respond with any items you are able to correct in the mean time. Thank you, Julianna M. Hutchinson Fire Inspector II City of San Luis Obispo Fire Department Fire Prevention 2160 Santa Barbara Avenue, San Luis Obispo, CA 93401-5240 E JHutchin@slocity.org T 805.783.7805 C 805.431.2217 slocity.org Stay connected with the City by signing up for e-notifications