HomeMy WebLinkAboutItem 5j. Attachment A - CADPS Phase 1A PlansetReference Documents:
City Standard Specifications - August 2020 Edition
City Engineering Standards - August 2020 Edition
1.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR
PERMITTEE TO CONTACT "UNDERGROUND SERVICE ALERT OF
NORTHERN CALIFORNIA" BY PHONE AT 8-1-1 FORTY-EIGHT (48)
HOURS PRIOR TO START OF CONSTRUCTION FOR LOCATION OF
POWER, TELEPHONE, OIL AND NATURAL GAS UNDERGROUND
FACILITIES. CONTRACTOR OR PERMITTEE SHALL ALSO
CONTACT THE APPROPRIATE AGENCY FOR THE LOCATION OF
CABLE T.V., WATER, SEWER, DRAINAGE OR UNDERGROUND
FACILITIES.
2.THE CONTRACTOR SHALL POSSESS A CLASS C-10 LICENSE AT
THE TIME OF BID OPENING.
index to plans
sheet no.description
general notes:
san luis obispo county, california
scope of work:
Cultural Arts District Parking
Structure - Phase 1A
Dry Utility Undergrounding
1 VICINITY MAP, GENERAL NOTES
2 GENERAL NOTES, VICINITY MAP
3 DRY UTILITY PLAN
4 ELECTRICAL DETAILS
APPROVED BY
SPECIFICATION NO.DATE
of
SHEET
Brian Nelson, City Engineer R.C.E. C79870 Approved Date
4June 2022
90435-1A 1FILE NO./LOCATION
PROJECT
LOCATION
1.New dry utility service conduits to serve existing building to remain along
the Broad, Nipomo, Monterey block.
2.Trenching in existing right of ways, new pull boxes, transormer pad, and
pole riser sweeps.
3.Utility providers to disconnect existing services, remove unused cables,
supply new service cables, and make all final terminations as necessary.
location map
OTTO ELECTRICAL, INC.
SAN LUIS OBISPO, CA
GOTTO@OTTOELECTRICAL.COM
805.459.4329
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
of
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
Cu
l
t
u
r
a
l
A
r
t
s
D
i
s
t
r
i
c
t
P
a
r
k
i
n
g
S
t
r
u
c
t
u
r
e
-
P
h
a
s
e
1
A
Dr
y
U
t
i
l
i
t
y
U
n
d
e
r
g
r
o
u
n
d
i
n
g
GO
GO
BN
BN
PER PLANS
JUNE 2022
90435-1A
4
Know what's below.
before you dig.Call
R
2
GE
N
E
R
A
L
N
O
T
E
S
,
V
I
C
I
N
I
T
Y
M
A
P
PROJECT
LOCATION
GENERAL NOTES
1.CODE COMPLIANCE: ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH CODES, STANDARDS, AND
ORDINANCES AS SET FORTH BY THE AUTHORITIES HAVING JURISDICTION AND THEIR LATEST ADOPTED EDITIONS (IN EFFECT AT
TIME OF BUILDING PERMIT APPLICATION) OF THE FOLLOWING PUBLICATIONS:
A.CALIFORNIA CODE OF REGULATIONS TITLE 24; INCLUDES 2019 CALIFORNIA ELECTRICAL CODE, 2019 CALIFORNIA FIRE
CODE, 2019 CALIFORNIA BUILDING CODE, ETC. WITH LOCAL AMENDMENTS AS APPLICABLE.
B.AMERICANS WITH DISABILITIES ACT (ADA).
2.SAFETY: THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN A SAFE AND RESPONSIBLE MANNER.
KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED. CONDUCT ALL CONSTRUCTION OPERATIONS IN A
SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER WORKPERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS,
FLAGS, TAPE, ETC. AS REQUIRED FOR SAFETY. THE CONTRACTOR SHALL HOLD ALL PARTIES HARMLESS OF NEGLIGENT
SAFETY PRACTICES, WHICH MAY CAUSE INJURY TO OTHERS ON OR NEAR THE JOB SITE.
3.LABEL PANELS, CABINETS, BACKBOARDS, MAIN DEVICES, SAFETY SWITCHES, CONTACTORS AND OTHER SPECIFICALLY
DESIGNATED EQUIPMENT SHOWN ON PLANS. USE ENGRAVED LAMINATED PLASTIC NAMEPLATES ATTACHED BY SCREWS OR
RIVETS. FOR FEEDERS, NEATLY AND INDELIBLY LABEL CONDUIT DESTINATIONS ON BOTH VISIBLE ENDS OF CONDUIT RUNS
WHERE CONDUITS TERMINATE AT DESIGNATED ENCLOSURES, STRUCTURES OR EQUIPMENT (INCLUDING PULL AND SPLICE
BOXES).
GENERAL SITE PLAN NOTES
A.ALL UTILITY WORK AND COORDINATION SHALL BE INSTALLED PER THE UTILITY COMPANY ISSUED CONSTRUCTION DRAWINGS
AND SPECIFICATIONS SPECIFIC TO THIS PROJECT. ANY UTILITY WORK PERFORMED WITHOUT PRIOR UTILITY COMPANY
APPROVAL SHALL BE DONE AT THE CONTRACTOR'S RISK. PG&E APPLICATIONS HAVE BEEN INITIATED BY ENGINEER:
PG&E ELECTRIC & GAS SERVICE REQUIREMENTS - GREENBOOK 2020-2021
051122 - CLEARANCES AND LOCATION REQUIREMENTS FOR ENCLOSURES, PADS, AND UNDERGROUND EQUIPMENT.
062288 - UNDERGROUND CONDUIT.
NOTIFICATION NUMBER: 11839790
PM NUMBER: 35323721
B.UTILITY COMPANY CONTACTS: BEFORE CONSTRUCTION, COORDINATE & VERIFY ALL UTILITY COMPANY REQUIREMENTS:
PG&E - JUSTIN MCDONALD, JUSTIN.MCDONALD@PGE.COM, 805.546.1271
C.TRENCHING AND BACKFILLING FOR ALL CONDUIT SYSTEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL
CONDUITS SHALL HAVE MINIMUM COVER REQUIREMENTS AS SPECIFIED IN CEC 300-5 AND PER CITY STANDARDS. MORE
STRINGENT DEPTH REQUIREMENTS MAY BE IMPOSED BY UTILITY COMPANY AND / OR THIS SPECIFICATION. JOINT TRENCHING
MAY BE UTILIZED WHERE PRACTICABLE AND WHERE PERMITTED BY THIS SPECIFICATION.
D.LOCATIONS OF EXISTING UNDERGROUND (UG) UTILITY SYSTEMS SHALL BE DETERMINED BY CALLING UNDERGROUND SERVICE
ALERT (USA). WHEN PLANNING UNDERGROUND WORK, AND BEFORE YOU DIG, CONTACT UNDERGROUND SERVICE ALERT (USA)
AT LEAST 48 HOURS PRIOR TO EXCAVATION (WEEKENDS EXCLUDED) FOR THE LOCATION OF UNDERGROUND GAS AND
ELECTRIC LINES OR EQUIPMENT.
E.MAINTAIN REQUIRED CLEARANCES FROM ALL SANITARY SEWER, WATER AND STORM DRAIN PIPING PER CITY STANDARD 6010.
F.ALL SITE UTILITY WORK SHALL BE INSTALLED PER THE UTILITY COMPANY ISSUED CONSTRUCTION DRAWINGS AND
SPECIFICATIONS SPECIFIC TO THIS PROJECT. ANY UTILITY WORK PERFORMED WITHOUT PRIOR UTILITY COMPANY APPROVAL
SHALL BE DONE AT THE CONTRACTOR'S RISK.
VICINITY MAP
NOT IN CONTRACT
ON CENTER
NOT TO SCALE
NORMAL POWER FACTOR
NORMALLY OPEN
NIGHT LIGHT
MAIN CIRCUIT BREAKER
MAIN FUSIBLE SWITCH
LOW VOLTAGE
LOW PRESSURE SODIUM
MAXIMUM OCP
MINIMUM CKT AMPS
LOCKED ROTOR AMPS
QUANTITY 1000
MAIN CATV TERMINAL CABINET
MANUAL TRANSFER SWITCH
NATIONAL ELECTRICAL CODE
LIFE SAFETY BRANCH
MAIN TELEPHONE TERMINAL CABINET
NEUTRAL (GROUNDED CONDUCTOR)
NAT'L ELEC MANUFACTURER'S ASSOC
NORMALLY CLOSED
MICROWAVE
MAIN TELEPHONE TERMINAL BOARD
MAIN SWITCHBOARD
MAIN LUGS ONLY
MOUNTING HEIGHT
METAL HALIDE
MANUFACTURER
MECHANICAL
MAIN CATV TERMINAL BOARD
MECHANICAL CONTRACTOR
LIGHTING CONTACTOR
KILOVOLTAMPS
NEMA 3R
MOUNT
LIGHTING
LIGHT
KILOWATT
NPF(F)FUTURE
FA
F-#
FIRE ALARM
FURNACE
OC
NTS
CURRENT TRANSFORMER
CALIFORNIA SFM
CONDUIT, CONDUCTOR
CONDUIT ONLY (W/PULLROPE)
CRITICAL BRANCH
COPPER
CONDENSING UNIT
CONTRACTOR
CIRCUIT
CENTER LINE
EM
ES
(EXR)
EXT
(EXN)
F
EMB
EQUIP'T
EMERG
EOL
EC-#
EL
EM
ELEC
EF-#
EB
EC
EA
(E)
CU-#
DW
DISC
DIST
DPST
DF
DIA
DC
D
COND
CSFM
CT
Cu
CR
C.O.
CKT
CNT'R
CL
MHEMERGENCY
FLUORESCENT
EMERGENCY BALLAST
(E) TO BE (R)
(E) IN (N) LOCATION
ENERGY SAVING
EXTERIOR
EMERGENCY
END OF LINE
EQUIPMENT
EVENING LIGHT
EMERG BATTERY BACKUP
ELECTRONIC BALLAST
EVAPORATIVE COOLER
ELECTRICAL CONTRACTOR
ELECTRICAL
EXHAUST FAN
EXISTING
EACH
NEC
NIC
NO
NL
NEMA
N
N3R
NC
(N)NEW
MT HT
MTTC
MTTB
MTS
MW
MOCP
MSB
MLO
MT
DOUBLE POLE SINGLE THROW
DRINKING FOUNTAIN
DIRECT CURRENT
DISHWASHER
DISTRIBUTION
DISCONNECT
DIAMETER
DEPTH
LV
MCTC
MECH
MFS
MFR
MCTB
MCB
MCA
MC
LPS
LS
LTG
LT
LRA
LC
kW
kVA
k
WEATHERPROOF (NEMA 3R)WP
INDICATES MOUNTING HEIGHT AFF
TRANSFORMER
+48
XFMR
TIME SWITCH OVERRIDE
TWISTED SHIELDED PAIR
VANDAL-RESISTANT
UNDERWRITERS LABORATORIES
SINGLE POLE SINGLE THROW
TYPICAL SIMILAR
TELEPHONE TERMINAL CABINET
VERY HIGH OUTPUT
TRANSFORMER, TERMINAL
WATER HEATER
WIDTH, WATT, WIRE
VOLT ALTERNATING CURRENT
VOLT AMPERES
UG SVC ALERT 800-642-2444
UNLESS OTHERWISE NOTED
UNDERGROUND PULL SECTION
UNDERCABINET, UNDERCOUNTER
TELEPHONE TERMINAL BOARD
TELEPHONE COMPANY
TO BE REMOVED
TELEPHONE CONDUIT
SLIMLINE, SWITCH LEG
VOLTAGE
UNDERGROUND
TIME CLOCK
TRANSFORMER
TIME SWITCH
TELEPHONE
SURFACE
STORAGE
SPECIFICATION
TTB
WH-#
USA
VHO
VAC
VOLT
VR
W
VA
V VOLT
UON
UGPS
TYP SIM
TTC
TYP
UC
UL
UG
TX
TYPICAL
T
TSP
TSO
TELCO
TEL
(TBR)
-T-
TS
TC
SURF
SVC
SPST
STR'G
SPEC
SHT
SQ
SW
SL
SQUARE
SWITCH
SERVICE
SHEET
HIGH INTENSITY DISCHARGE
FIRE ALARM CONTROL PANEL
HAND-OFF-AUTO
INSIDE FROST
IDENTIFICATION
HIGH OUTPUT
ISOLATED GROUND
JUNCTION BOX
HORSEPOWER
HIGH PRESSURE SODIUM
HIGH POWER FACTOR
INTERCOM
FULL VOLTAGE NON-REVERSING
HEATING, AC & REFRIG
FULL LOAD AMPS
FUSIBLE SWITCH
FURNISHED BY OTHERS
HEIGHT, HIGH
GANG WITH SWITCH
GALVANIZED RIGID STEEL
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT CIRCUIT INTERRUPTER
GARBAGE DISPOSAL
GENERAL CONTRACTOR
GROUNDING CONDUCTOR
FLUORESCENT
FORCED AIR UNIT
FIRE ALARM TERMINAL
GROUND
FLOOR
FAN COIL
CONDUIT
CALIFORNIA FIRE CODE
CA. BUILDING CODE
CA. ENERGY COMMISSION
COMPACT FLUORESCENT
CABINET
CEILING
CA. ELECTRICAL CODE
CIRCUIT BREAKER, CODE BLUE
CATV CONDUIT
CABLE TELEVISION
AUTOMATIC TIME SWITCH
AMERICAN WIRE GAGE
AUTOMATIC TRANSFER SWITCH
AMP BREAKER
AUDIBLE/AUDIO VISUAL
ALUMINUM
AMP SWITCH RATING
AMPERES INTERRUPTING CAPACITY
ABOVE FINISH GRADE
ABOVE FINISH FLOOR
AMP FUSE, AMP FRAME
ALTERNATING CURRENT
AIR CONDITIONER
ABOVE
ABANDONED
AMPERE
ABBREVIATIONS
ADJACENT
AS
-C-
CEC
CFC
CF
CLG
CBC
CAB'T
CATV
CB
BIL
BLDG
BFG
C
AV
AWG
ATS
ATS
AF
AFG
AIC
AFF
Al
AC
AC-#
ABV
ADJ
AB
ABAND
A
GD
BASIC IMPULSE LEVEL
BELOW FINISH GRADE
BUILDING
HO
IC
J-BOX
IF
ID
IG
HOA
HPF
HPS
hp
HID
HACR
GWS
H
GND
GRS
GFI
GFCI
FLUOR
FVNR
G
GC
FS
FC-#
FLA
FLR
FBO
FACP
FAU
FAT
REMOTE TERMINAL UNIT
STATE FIRE MARSHAL
RATED LOAD AMPS
PLANNING & DEVELOPMENT
OFFICE of STATEWIDE HEALTH
OFFICE of the STATE ARCHITECT
POINT OF CONNECTION
RIGID METAL CONDUIT
PLUMBING CONTRACTOR
SHORT CKT CURRENT
POWER SECONDARY
POWER PRIMARY
PUBLIC ADDRESS
OUTSIDE DIAMETER
REFRIGERATOR
OVERCURRENT PROTECTION
RAPID START
REPLACE
REQUIRED
PULLBOX
PULL CHAIN
RECEPTACLE
RELOCATE(D)
PHOTOCELL
OVERHEAD
OVERLOAD
PC
REQ'D
RPLC
SFM
SCC
RLA
RMC
RMV
RTU
RS
RM
REMOVE
ROOM
REF
POC
-PP-
-PS-
(R)
RECEPT
PNL
ph PHASE
PANEL
OSHPD
OVLD
OSA
P
PB
PC
PC
PA
POLE
OCP
OH
OD
PHOTOVOLTAICPV
SS
SS
SS
SS
SSSSSSSSSS
SS
SSSS
SS
SS
SS
24" OLIVE
ATT
W
V
W
V
S
L
B
P
G
E
C
T
V
W
M
W
M
W
M
P
G
E
C
T
V
P
G
E
WM
ELEC
ELEC
ICV
WV
WV
W
M
C
A
T
V
P
G
E
T
E
L
G
A
S
EM
18" PINE
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
8
"
P
I
N
E
W
V
S
C
O
T
R
E
E
1
4
"
T
R
E
E
6
"
W
S
P
A
C
B
E
L
L
C
O
CO
IC
V
IC
V
18" TREE
1
8
"
T
R
E
E
1
0
"
O
A
K
8"
T
R
E
E
18
"
E
U
K
2
6
"
E
U
K
16" TR
E
E
36" TR
E
E
28" TR
E
E
24" PIN
E
26" PINE
TRASH
10" PINE
12" OAK
U
T
I
L
2P TREE 12" & 6"
/
/
/
3
P
T
R
E
E
3
6
"
B
A
S
E
/////////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
WL
WL
WL
WL
WL
WL
WL
WL
WL
WL
WL
WL
WL
1
4
"
T
R
E
E
6
"
T
R
E
E
4
0
"
T
R
E
E
C
O
10" TREE
CO
4" TREE
TEL
T
R
A
S
H
ICV
12" TREE
C
T
V
U
T
I
L
U
T
I
L
WM
W
V
1
4
"
T
R
E
E
1
0
"
T
R
E
E
W
V
W
V
W
V
UTIL
U
T
I
L
W
M
G
A
S
S
16" TREE
8" 3P TREE 8" & 14"
2P TREE
WM WM
PAC BELL
WM
1
4
"
O
A
K
1
2
"
T
R
E
E
2
2
"
T
R
E
E
P
L
A
N
T
E
R
40" TREE
W
V
w
TRASH
PG&E PAD MOUNT TRANSFORMER
50"X52" PAD AND PROTECTIVE BOLLARDS
PER PG&E REQUIREMENTS
EXISTING PG&E POLE
CHARTER TIE IN AT EXISTING
VAULT AT WEST SIDE BROAD ST.
RELEVEL PULL BOXES AND
COVERS TO BE FLUSH WITH NEW
SIDEWALK.
EXISTING AT&T CONDUIT.
PROTECT IN PLACE. PROVIDE
NEW ADJACENT AT POLE.
PG&E , AT&T, AND CHARTER
TO REPLACE EXISTING POLE
AND SERVICE DROPS
PG&E , AT&T, AND CHARTER
TO REPLACE OVERHEAD
SERVICE CABLES.
CHARTER PULL BOX. 2'X3'
AT&T PULL BOX. 17"X30"
REMOVE AND REPLACE
EXISTING CURB, GUTTER,
AND SIDEWALK PER CITY
STANDARD 4220. SALVAGE
GRANITE CURB TO CITY
CORPORATION YARD AS
DIRECTED BY THE ENGINEER
(285 SQ. FT)
AT&T TIE IN AT EXISTING VAULT
AT WEST SIDE BROAD ST.
RELEVEL PULL BOXES AND
COVERS TO BE FLUSH WITH NEW
SIDEWALK.
REMOVE AND REPLACE
EXISTING CURB, GUTTER,
AND SIDEWALK PER CITY
STANDARD 4220. SALVAGE
GRANITE CURB TO CITY
CORPORATION YARD AS
DIRECTED BY THE ENGINEER
(270 SQ. FT.)
INTERCEPT EXISTING
PRIMARY CONDUIT AND
EXTEND INTO NEW PG&E
VAULT. COORDINATE WORK
WITH PG&E.
EXISTING PG&E VAULT
C
4
B
4 A
4
190LF
170LF
160LF
32'±
9'±
PROTECT IN PLACE
ROCK WALL
PROVIDE 12" CLEARANCE
TO GAS LINES.
PROVIDE 12" CLEARANCE TO
GAS LINES.
REMOVE EXISTING
LANDSCAPING
37'±
8'±
REPLACE HI-VIS CROSSWALK
PER CITY STANDARD 7350 REMOVE EXISTING PARKING
METERS
REMOVE AND REPLACE
EXISTING CURB, GUTTER,
AND SIDEWALK PER CITY
STD. 4220. ADJUST UTILITY
BOXES TO FINISHED
SURFACE. PAINT CURB RED.
(88 SQ. FT.)
11'±
8'±
REPLACE HI-VIS CROSSWALK
PER CITY STANDARD 7350
4" SPARE CONDUIT
STUBBED INTO PLANTER
AREA FOR FUTURE USE.
975
696
680
664658
PROPERTY LINE (TYP)
NORTH
SCALE:
DRY UTILITY PLAN - BROAD AND MONTEREY STREET
1" = 20'-0"
OTTO ELECTRICAL, INC.
SAN LUIS OBISPO, CA
GOTTO@OTTOELECTRICAL.COM
805.459.4329
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
of
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
Cu
l
t
u
r
a
l
A
r
t
s
D
i
s
t
r
i
c
t
P
a
r
k
i
n
g
S
t
r
u
c
t
u
r
e
-
P
h
a
s
e
1
A
Dr
y
U
t
i
l
i
t
y
U
n
d
e
r
g
r
o
u
n
d
i
n
g
GO
GO
BN
BN
PER PLANS
JUNE 2022
90435-1A
4
Know what's below.
before you dig.Call
R
LEGEND
#5 PG&E ENCLOSURE 3'X5'X3'6" INSTALLED BY CONTRACTOR PG&E CODE 025601 SPLICE BY PG&E
#6 PG&E ENCLOSURE 4'X6'6"X5' INSTALLED BY CONTRACTOR PG&E CODE 041495 JAY BY PG&E
EXISTING DRY UTILITY VAULT/BOX TO REMAIN. PROTECT IN PLACE. REPAIR AND REPLACE LID IF DAMAGED.
1-4" CONTRACTOR INSTALLED DUCT. PG&E INSTALLED 2-1/0A EPE-CONC-ENCAP
1-4" CONTRACTOR INSTALLED DUCT. PG&E INSTALLED 3-1/0A EPE-CONC-ENCAP
1-5" CONTRACTOR INSTALLED DUCT. PG&E INSTALL 750A TPX
1-3" CONTRACTOR INSTALLED DUCT. CHARTER INSTALLED CABLE.
1-4" CONTRACTOR INSTALLED DUCT. AT&T INSTALLED CABLES.
EXISTING DRY UTILITY CONDUIT TO REMAIN. PROTECT IN PLACE.
EXISTING DRY UTILITY CONDUIT TO BE REMOVED. COORDINATE REMOVAL WITH UTILITY PROVIDER.
EXISTING OVERHEAD CABLES
EXISTING GAS UTILITY. FIELD LOCATE FOR ADDITIONAL PIPES NOT SHOWN ON DRAWING.
EXISTING WATER LINE. FIELD LOCATE FOR ADDITIONAL PIPES NOT SHOWN ON DRAWING.
EXISTING SEWER LINE. FIELD LOCATE FOR ADDITIONAL PIPES NOT SHOWN ON DRAWING.
3
DR
Y
U
T
I
L
I
T
Y
P
L
A
N
GENERAL NOTE
A.ANY STRIPING AND PAVEMENT MARKINGS REMOVED WITHIN THE LIMITS OF WORK MUST BE REPLACED.
B.ROUTING OF NEW UTILITIES ARE ONLY A SUGGESTION. NOT ALL UTILITIES ARE SHOWN. DRY UTILITIES SUCH AS
CATV, TELEPHONE, FIBER, AND POWER ARE LOCATED WITHIN THE PROJECT AREA. CONTRACTOR SHALL LOCATE
EXISTING UTILITIES PRIOR TO STARTING WORK, CONTRACTOR SHALL ADJUST ROUTING TO AVOID EXISTING
UTILITIES AND MAINTAIN CLEARANCES PER MOST RESTRICTIVE UTILITY STANDARDS/REQUIREMENTS.
C.NOT ALL LATERALS ARE SHOWN ON PLANS. LOCATING LATERALS IS THE RESPONSIBILITY OF THE CONTRACTOR
AND ANY DAMAGE TO A LATERAL MUST BE REPAIRED IMMEDIATELY AND AT NO COST TO THE CITY.
D.ARCHEOLOGICAL MONITORING REQUIRED FOR TRENCHING WITHIN BROAD AND MONTEREY.
TRACER WIRE
WARNING
TRACER TAPE
2" MIN
~9" MIN
REFER TO CITY STANDARD
DETAILS 6010, 6020, 6030, 6040
FOR ADDITIONAL TRENCH AND
LOCATION REQUIREMENTS.
_
12"
MAX
P2 4" MIN
BACKFILL TRENCH PER CITY
STANDARD 6035
*NOTE: BROAD AND MONTEREY IS PAVED WITH AC OVER PCC. AC OVER
PCC PAVEMENT RESTORATION PER CITY STANDARD 4110 AND 6020
36" BELOW CROSSING
UTILITIES OR 84" BELOW
TOP OF CURB,
WHICHEVER IS DEEPER
WARNING
TRACER TAPE
2" MIN
~13" MIN
REFER TO CITY STANDARD
DETAILS 6010, 6020, 6030, 6040
FOR ADDITIONAL TRENCH AND
LOCATION REQUIREMENTS.
_
12"
MAX
S1 4" MIN
TRACER WIRE
T4
12" MIN
C2
2" MIN
TEE CUT WITH THE WIDTH OF THE AC CUT EXTENDED ONE
FOOT EACH SIDE OF TRENCH. 6' AC TO BE CONSTRUCTED
BY PLACING 4" THICK AC (1/2" AGGREGATE), PAVING GRID
(GLASGRID 8502, STARGRID G-PS 200-100, OR APPROVED
EQUAL) AND 2" AC THICK SURFACE COURSE (1/2"
AGGREGATE)
BACKFILL TRENCH PER CITY
STANDARD 6035
36" BELOW CROSSING
UTILITIES OR 84" BELOW
TOP OF CURB,
WHICHEVER IS DEEPER
WARNING
TRACER TAPE
2" MIN
~13" MIN
REFER TO CITY STANDARD
DETAILS 6010, 6020, 6030, 6040
FOR ADDITIONAL TRENCH AND
LOCATION REQUIREMENTS.
_
12"
MAX
4" MIN
TRACER WIRE
T4 C2
2" MIN
BACKFILL TRENCH PER CITY
STANDARD 6035
TRENCHING WITHIN STREET
SECTION PER CITY STANDARD
6020 CASE 2.
*NOTE: BROAD AND MONTEREY IS PAVED WITH AC OVER PCC. AC OVER
PCC PAVEMENT RESTORATION PER CITY STANDARD 4110 AND 6020
36" BELOW CROSSING
UTILITIES OR 84" BELOW
TOP OF CURB,
WHICHEVER IS DEEPER
OTTO ELECTRICAL, INC.
SAN LUIS OBISPO, CA
GOTTO@OTTOELECTRICAL.COM
805.459.4329
CITY SPECIFICATION NO.
DATE:
PR
O
J
E
C
T
T
I
T
L
E
:
SH
E
E
T
T
I
T
L
E
:
of
SHEET NO.
DESIGNED BY:
DRAWN BY:
CHECKED BY:
APPROVED BY:
SCALE:
PLAN FILE NO. / LOCATION
Cu
l
t
u
r
a
l
A
r
t
s
D
i
s
t
r
i
c
t
P
a
r
k
i
n
g
S
t
r
u
c
t
u
r
e
-
P
h
a
s
e
1
A
Dr
y
U
t
i
l
i
t
y
U
n
d
e
r
g
r
o
u
n
d
i
n
g
GO
GO
BN
BN
PER PLANS
JUNE 2022
90435-1A
4
Know what's below.
before you dig.Call
R
4
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
ATRENCH SECTION B DETAIL
NTS
TRENCH SECTION A DETAIL
SCALE:NTSB
TYPICAL BOLLARD DETAIL1NTS
NOTE: EXACT LOCATIONS OF PIPE BOLLARDS
SHALL BE FIELD COORDINATED AND LOCATED
AROUND EQUIPMENT SO THAT DOORS FULLY
OPEN AND WORKING CLEARANCES ARE
PRESERVED.3"
12"
32"
42"
UNREINFORCED CONCRETE
FOOTING
FINISHED GRADE
4" DIAMETER STEEL POST
FILLED WITH CEMENT GROUT,
PAINT EXTERIOR SURFACE OF
POST YELLOW.
REFLECTIVE TAPE (TYPICAL)
SCALE:
TRENCH SECTION C DETAIL
NTSCSCALE:
6"
GROUT
24"-36"
CRUSHED ROCK SUMP (18" MIN DEPTH)
BELL END
2" DIA DRAIN6"HOLE
FINISHED GRADE
REINFORCED CONCRETE OR
POLYMER COVER (TO SUIT
APPLICATION). LABEL COVER
PER UTILITY REQUIREMENTS.
PRECAST REINFORCED
CONCRETE OR
POLYMER CONCRETE
BOX. SIZE PER PLANS.
SEAL AROUND
CONDUIT, BOX AND
EXTENSION JUNCTION.
PRECAST
REINFORCED
EXTENSION
#15 ROOFING PAPER
BETWEEN GROUT AND
CRUSHED ROCK
2 TYPICAL AT GRADE PULL BOX DETAIL
SCALE:NTS
*TRENCH DEPTH NOTE:
DEPTH OF CONDUITS ARE SHOWN AS MINIMUMS. IN ORDER TO
AVOID OTHER UTILITY CROSSINGS THAT THE DEPTH OF
TRENCH MAY NEED TO BE INCREASED TO PROVIDE SUFFICIENT
CLEARANCE BELOW EXISTING UTILITIES AS DIRECTED BY THE
ENGINEER.