Loading...
HomeMy WebLinkAboutBLDG-2883-2023_STAMPED TRUSS CALCS 02/27/2024November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division Order#: 7330M Salesperson: Mark Herring Designer: Mark Herring Company Code: OB Invoice#: 7330M P.O. Box 850 Guadalupe, CA. 93434 Phone: (805) 343-2555 Fax: (805) 343-2377 Steve@TrusPro.com www.TrusPro.com TrusPro Structural Components Inc Bill Of Lading Name: Address: City, State, Zip: Phone:Fax: Bill To _Owner/Builder CA (___) ___-____(___) ___-____ San Luis Obispo, CA _____ 133 Foothill Ship To Fax:Phone: City, State, Zip: Address: Name: Job Name:7330M Contact: Phone Job Description:Twisselman ADU Fax _Owner/BuilderCustomer: Qty Truss ID SpanProfile Overhangs Heel Heights Wght.Pitch HeightLeftRightRightLeft 1-4-0 1-4-15 2-0-02-0-0 2 2 8316-0-01A123 0-5-13 2-0-13 2-0-02419-6-02B02 0-5-13 2-0-13 2-0-02439-6-02B120 0-5-13 2-0-13 2-0-02439-6-02B25 Total Lineal Feet 21421702 Total Board Feet Max Truss HeightTotal Truss WeightMax SpanTotal Trusses 50 3066 lbs16-0-0 4-4-0 WARRANTIES PROVISIONS: Supplier warrants for one year from date of delivery that its manufactured Products shall be new and of industry standard quality in the trade and within the description set forth in this Agreement. Any items not manufactured by Supplier are warranted only as warranted by the manufacturer of such items, otherwise all such items are sold on an “AS IS” basis. THE FOREGOING WARRANTIES ARE EXCLUSIVE, AND ARE IN LIEU OF ALL OTHER WARRANTIES (WHETHER WRITTEN, ORAL, OR IMPLIED AND INCLUDING ANY REGARDING THE MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) NOT SPECIFIED HEREIN, RESPECTING THIS CONTRACT. Supplier’s warranty shall exclude losses caused by improper operating, storing, handling, installation, and bracing. Supplier’s obligations and liabilities under this Contract are expressly and exclusively limited to repair or replacement of defective Products or, at the option of the Supplier, to the refund of the purchase price. IN NO EVENT SHALL THE CONTRACTOR BE ENTITLED TO RECOVER FOR INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGE, INCLUDING THE LOSS OF PROFITS, OR OTHER COMMERCIAL LOSS. DEFAULT AND TERMINATION PROVISIONS: In case of a good faith claim against Supplier for any defect or non-conformity with respect to the Products sold, written notice setting forth such defect or non- conformity must be submitted to Supplier within 30 days of truss delivery. Supplier shall have no less than 7 business days from date of receipt of such notice to either accept such claim or commence any necessary repair or replacement of Product. Upon termination for convenience, Supplier shall be paid for all Products manufactured and delivered. By signing below, it is agreed that at least one set of bracing and installation instructions have been received with this order. Accepted By:____________________________________ Date:_____________ 10/31/2023 11:01:48 AM 1 of 1Eagle Metal Products - TrueBuild® Report Engine v5.5.30.2 Job# 7330M 1500 lbs (2) (23) 1A1 2B 0 2B 0 (13) 2B1 (7) 2B1 (5) 2B2 16 ' 0 " 9' 6 " 47' 6" 15 0 0 # D R A G 15 0 0 # D R A G 7330M Twisselman ADU 133 Foothill San Luis Obispo, CA The truss designs referenced below have been prepared by me or under my direct supervision based on the truss design criteria and requirements ("design criteria") provided by TrusPro Structural Components IncTrusPro Structural Components Inc . These truss designs are intended for the fabrication of individual building components that will perform to the design criteria provided. Any variance from the design criteria will render the affected truss designs inapplicable. Listed below are the truss designs included in this package and covered by this seal. Job: 7330M7330M - 1197618 1A1, 2B0, 2B1, 2B2 Any location identification is for file reference only. No determination of the appropriateness of design criteria for any specific project has been made in preparing the truss designs. Please refer to individual truss designs for specific design criteria. Arturo A. Hernandez (CA, C72517) My license expiration date for the state of CA is 06/30/2024. IMPORTANT NOTE: The responsibility of the engineer sealing this package, as a Truss Engineer, is solely for design of individual trusses as individual building components based upon design criteria provided by others and set forth in the referenced truss drawings. The truss design criteria for the components have not been verified as appropriate for any particular building, project or use. Adequacy and suitability of design criteria and requirements for the truss designs for any specific project are the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. Empowering great component manufacturers. 1197618 0001/0006 1.The Truss Design Drawing(s) provided with these Design Notes have been prepared under and are subject to ANSI / TPI 1 published by the Truss Plate Institute, www.tpinst.org. Capitalized terms have the meanings provided in ANSI / TPI 1. 2.Copies of each Truss Design Drawing shall be furnished to the installation contractor, Building Designer, Owner and all persons fabricating, handling, installing, bracing, or erecting the trusses. DESIGN LIMITATIONS 3.The Truss Design Drawing is based upon specifications provided by the Building Designer in accordance with ANS1 / TPl 1. Neither the Truss Designer, Eagle, nor an engineer who seals this design (if any) assumes any responsibility for the adequacy or accuracy of specifications provided by the Building Designer. 4.The Building Designer is solely responsible for the suitability based upon the Truss Design Drawing and shall be responsible for reviewing and verifying that the information shown is in general conformance with the design of the Building. 5.Each Truss Design Drawing is for the individual building component (a truss). A seal on the Truss Design Drawing indicates acceptance of professional engineering responsibility solely for the individual truss. 6.Each Truss Design Drawing assumes trusses will be suitably protected from the environment. HANDLING, INSTALLING, & BRACING 7.Refer to Building Component Safety Information (BCSI) for handling, installing, restraining and bracing trusses. Copies can be obtained from the Structural Building Components Association, www.sbcindustry.com. 8.Bracing shown on each Truss Design Drawing is for lateral support of individual truss components only to reduce buckling lengths. All temporary and permanent bracing, including lateral load and diagonal or cross bracing, are the responsibility, respectively, of the erector and Building Designer. 9.Eagle is not responsible for improper truss fabrication, handling, erection or bracing. 10.Compression chords shall be laterally braced by the roof or floor sheathing, directly attached, or have purlins provided at spacing shown, unless noted otherwise. DESIGN NOTES REFERENCES •ANSI / TPI 1: National Design Standard for Metal Plate Connected Wood Trusses •BCSI: Building Component & Safety Information - Guide to Good Practice for Handling, Installing, Restraining, & Bracing of Metal Plate Connected Wood Trusses. •NDS: National Design Specification for Wood Construction •ESR: 1082 published by the International Code Council. www.icc-es.org SYMBOLS PLATE SIZE 3X4 - The first dimension is the width perpendicular to slots. Second dimension is the length parallel to slots. -, /, I, Indicates required direction of slots; Reference “Joint Details” for more information. 20 Ga Gr40 connectors required 3X10-20HS - 20 Ga Gr60 connectors required 8X10-18HS - 18 Ga Gr60 connectors required LATERAL BRACING When this symbol shown, continuous lateral bracing is required on the member of the truss. BEARING Indicates location where bearings (supports) occur. PLATE LOCATION & ORIENTATION The plate shall be centered on joint and/or placed in accordance with the design drawing/QC full scale details. 11.Bottom chord required bracing shall be at 1Oft spacing or less, if no structural rated ceiling is installed, unless noted otherwise. 12.Strongbacking shall be installed on all parallel chord trusses, including flooring systems, to limit deflection and reduce vibration. Refer to BCSI-B7. 13.Never exceed the design loading shown. Never stack building or other materials on inadequately braced truss; refer to BCSI. 14.Concentration of construction loads greater than the design loads shall not be applied to the trusses at any time; refer to BCSI. 15.Trusses shall be handled with care prior to erection to avoid damage. Refer to BCSI for recommended truss handling and erection. MATERIALS & FABRICATION 16.Lumber moisture content shall be 19% or less at the time of fabrication unless noted otherwise. 17.Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 18.Unless expressly noted, the truss designs are not applicable for use with fire retardant or preservative treated lumber. 19.Plates shall be applied on both faces of truss at each joint and embedded fully. Knots and wane at joint locations shall be regulated in accordance with ANSl / TPl 1. 20.For a specified plate gauge and grade, the specified size is a minimum. 21.Connections not shown are the responsibility of others. 22.Adequate support shall be provided to resist gravity, lateral and uplift loads. 23.For 4X2 truss orientation, locate plates 0 - 1/16” from outside the edge of the truss. 24.Fabrication of truss shall be in accordance with ANSI / TPI 1. OTHER NOTES 25.Camber is a non-structural consideration and is the responsibility of truss fabricator. 26.Do not cut or alter any truss member or plate without prior approval from a professional engineer. 27.Lumber design values are in accordance with ANSI / TPI 1; lumber design values are by others. 28.Install specified hangers per manufacturer recommendations. WARNING: Failure to follow may result in property damage or personal injury. 042020 ® 1197618 0002/0006 TrusPro Inc. 695 Obispo Street Guadalupe, CA 93434 Ph: (805)343-2555 Fax: (805)343-2377 Truss:1A1 Job: 7330M Date: 10/30/23 19:25:48 Page: 1 of 1 Notes: All connector plates to be Eagle 20 gauge unless otherwise noted SPAN PITCH QTY OHL OHR CANT L CANT R PLYS SPACING WGT/PLY 16-0-0 2 /12 23 2-0-0 2-0-0 0-0-0 0-0-0 1 24 in 83 lbs ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING ANY TRUSS BASED UPON THIS TRUSS DESIGN DRAWING ARE INSTRUCTED TO REFER TO ALL OF THE INSTRUCTIONS, LIMITATIONS AND QUALIFICATIONS SET FORTH IN THE EAGLE METAL PRODUCT'S DESIGN NOTES ISSUED WITH THIS DESIGN AND AVAILABLE FROM EAGLE UPON REQUEST. DESIGN VALID ONLY WHEN EAGLE METAL CONNECTORS ARE USED. TrueBuild® Truss Software v5.6.429.2 Eagle Metal Products 20-0-0 2-0-0 2-0-05-4-0 5-4-0 5-4-0 10-8-0 5-4-0 16-0-0 0-0-0 2-8-0 2-8-0 5-4-0 8-0-0 5-4-0 13-4-0 2-8-0 16-0-0 2-7-1 4- 4 - 0 1- 4 - 0 2- 7 - 1 1- 8 - 1 5 1- 4 - 1 5 -0 - 1 - 0 1- 0 - 5 2 12 212 10 14x4 / 24x4 / 37x8 / 48x12 /11 51.5x3 | 64x4 / 73x4 / 84x4 /91.5x3 | All plates shown to be Eagle 20 unless otherwise noted. Loading (psf) TCLL : 20 TCDL : 13(rake) BCLL : 0 BCDL : 8(rake) General Bldg Code : CBC 2022/ TPI 1-2014 Rep Mbr : Yes Lumber D.O.L. : 125 % CSI TC : 0.23 (4-11) BC : 0.41 (7-8) Web : 0.42 (1-8) Deflection L/ (loc) Allowed Vert TL: 0.23 in L / 791 (7-8) L / 240 Vert LL: 0.07 in L / 999 7 L / 360 Horz TL: 0.01 in 4 Reaction JT Brg Combo Brg Width Rqd Brg Width Max React Max Grav Uplift Max MWFRS UpliftMax C&C Uplift Max Uplift Max Horiz 9 1 5.5 in 1.50 in 772 lbs · -102 lbs -218 lbs -218 lbs 159 lbs 4 1 5.5 in 1.50 in 815 lbs · -152 lbs -275 lbs -275 lbs · Material Bracing TC: DFL #2 2 x 6 TC: Sheathed or Purlins at 5-5-0, Purlin design by Others. BC: DFL #2 2 x 4 BC: Sheathed or Purlins at 10-0-0, Purlin design by Others. Web: SPF Stud 2 x 4 Loads 1) This truss has been designed for the effects due to non-concurrent 10 psf bottom chord live load plus dead loads. 2) This truss has been designed for the effects of wind loads in accordance with ASCE7 - 16 with the following user defined input: 110 mph (Factored), Exposure C, Enclosed, Gable, Risk Category II, h=B=L=10 ft, Not End Zone Truss, Both end webs considered. DOL = 1.60 3) Non-concurrent minimum storage attic loading has been applied in accordance with IBC 1607.1 4) A 300 lbs moving/sprinkler point load (distributed over three trusses) has been applied to the TC concurrent with other dead loads. Member Forces Table indicates: Member ID, max CSI, max axial force, (max compr. force if different from max axial force). Only forces greater than 300lbs are shown in this table. TC 1-2 0.160 -1,077 lbs 2-3 0.201 -2,003 lbs 3-4 0.219 -854 lbs BC 6-7 0.381 1,796 lbs (-290 lbs)7-8 0.406 1,937 lbs (-362 lbs) Web 1-9 0.152 -753 lbs 1-8 0.419 1,059 lbs (-60 lbs) 2-8 0.276 -1,002 lbs 3-7 0.140 354 lbs 3-6 0.249 -961 lbs 4-6 0.395 998 lbs (-85 lbs) Notes 1) Unless noted otherwise, do not cut or alter any truss member or plate without prior approval from a Professional Engineer. 2) This truss has been designed using the green service reduction factors. 3) The fabrication tolerance for this roof truss is 20 % (Cq = 0.80). 4) Brace bottom chord with approved sheathing or purlins per Bracing Summary. 5) A creep factor of 2.00 has been applied for this truss analysis. 6) Horizontal clearance between inside face of bearing and where the outside edge of the end web meets the bottom side of the top chord shall not exceed 0.5" 7) Listed wind uplift reactions based on MWFRS & C&C loading. 1197618 0003/0006 TrusPro Inc. 695 Obispo Street Guadalupe, CA 93434 Ph: (805)343-2555 Fax: (805)343-2377 Truss:2B0 Job: 7330M Date: 10/30/23 19:25:49 Page: 1 of 1 Notes: All connector plates to be Eagle 20 gauge unless otherwise noted SPAN PITCH QTY OHL OHR CANT L CANT R PLYS SPACING WGT/PLY 9-6-0 2 /12 2 2-0-0 0-0-0 0-0-0 0-0-0 1 24 in 41 lbs ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING ANY TRUSS BASED UPON THIS TRUSS DESIGN DRAWING ARE INSTRUCTED TO REFER TO ALL OF THE INSTRUCTIONS, LIMITATIONS AND QUALIFICATIONS SET FORTH IN THE EAGLE METAL PRODUCT'S DESIGN NOTES ISSUED WITH THIS DESIGN AND AVAILABLE FROM EAGLE UPON REQUEST. DESIGN VALID ONLY WHEN EAGLE METAL CONNECTORS ARE USED. TrueBuild® Truss Software v5.6.429.2 Eagle Metal Products 11-6-0 2-0-0 9-6-0 9-6-0 0-0-0 9-6-0 9-6-0 0-0-0 2- 4 - 9 2- 0 - 1 3 0- 5 - 1 3 2 12 12 14x6 - 22x4 |32x4 |42x4 |52x4 | 61.5x3 | 71.5x3 |81.5x3 |91.5x3 |101.5x3 |111.5x3 | All plates shown to be Eagle 20 unless otherwise noted. Loading (psf) TCLL : 20 TCDL : 13(rake) BCLL : 0 BCDL : 8 General Bldg Code : CBC 2022/ TPI 1-2014 Rep Mbr : No Lumber D.O.L. : 125 % CSI TC : 0.17 (1-2) BC : 0.07 (11-1) Web : 0.06 (6-7) Deflection L/ (loc) Allowed Vert TL: 0 in L / 999 (11-1) L / 240 Vert LL: 0 in L / 999 (11-1) L / 360 Horz TL: 0 in Reaction Brg Combo Brg Width Rqd Brg Width Max React Max Grav Uplift Max MWFRS UpliftMax C&C Uplift Max Uplift Max Horiz 1 114 in N/A 90 lbs · -9 lbs -34 lbs -34 lbs -25 lbs 1 114 in N/A 121 lbs · -20 lbs -53 lbs -53 lbs · 1 114 in N/A 113 lbs · -16 lbs -58 lbs -58 lbs · 1 114 in N/A 103 lbs · -16 lbs -47 lbs -47 lbs · 1 114 in N/A 182 lbs · -27 lbs -63 lbs -63 lbs · 1 114 in N/A 319 lbs -119 lbs -74 lbs -249 lbs -249 lbs -1,049 lbs 1 114 in N/A 158 lbs -50 lbs · · -50 lbs 554 lbs Material Bracing TC: DFL #2 2 x 6 TC: Sheathed or Purlins at 6-3-0, Purlin design by Others. BC: DFL #2 2 x 4 BC: Sheathed or Purlins at 10-0-0, Purlin design by Others. Web: DFL #2 2 x 3 Loads 1) This truss has been designed for the effects due to a 1,500 lbs (128.7 plf) drag load distributed along the TC rake from each direction. 2) This truss has been designed for the effects of wind loads in accordance with ASCE7 - 16 with the following user defined input: 110 mph (Factored), Exposure C, Enclosed, Gable, Risk Category II, h=B=L=10 ft, Not End Zone Truss, Both end webs considered. DOL = 1.60 3) A 300 lbs moving/sprinkler point load (distributed over three trusses) has been applied to the TC concurrent with other dead loads. Member Forces Table indicates: Member ID, max CSI, max axial force, (max compr. force if different from max axial force). Only forces greater than 300lbs are shown in this table. TC 1-2 0.168 -1,095 lbs 2-3 0.098 -722 lbs 3-4 0.061 -546 lbs 4-5 0.042 -370 lbs BC Web Notes 1) Unless noted otherwise, do not cut or alter any truss member or plate without prior approval from a Professional Engineer. 2) Gable requires continuous bottom chord bearing. 3) Gable webs placed at 16 " OC, U.N.O. 4) Attach gable webs with 1.5x3 20ga plates, U.N.O. 5) Bracing shown is for in-plane requirements. For out-of-plane requirements, refer to BCSI-B3 published by the SBCA. 6) This truss has been designed using the green service reduction factors. 7) The fabrication tolerance for this roof truss is 20 % (Cq = 0.80). 8) A creep factor of 2.00 has been applied for this truss analysis. 9) Due to negative reactions in gravity load cases, special connections to the bearing surface at joints 1, 1 may need to be considered. 10) Listed wind uplift reactions based on MWFRS & C&C loading. 1197618 0004/0006 TrusPro Inc. 695 Obispo Street Guadalupe, CA 93434 Ph: (805)343-2555 Fax: (805)343-2377 Truss:2B1 Job: 7330M Date: 10/30/23 19:25:49 Page: 1 of 1 Notes: All connector plates to be Eagle 20 gauge unless otherwise noted SPAN PITCH QTY OHL OHR CANT L CANT R PLYS SPACING WGT/PLY 9-6-0 2 /12 20 2-0-0 0-0-0 0-0-0 0-0-0 1 24 in 43 lbs ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING ANY TRUSS BASED UPON THIS TRUSS DESIGN DRAWING ARE INSTRUCTED TO REFER TO ALL OF THE INSTRUCTIONS, LIMITATIONS AND QUALIFICATIONS SET FORTH IN THE EAGLE METAL PRODUCT'S DESIGN NOTES ISSUED WITH THIS DESIGN AND AVAILABLE FROM EAGLE UPON REQUEST. DESIGN VALID ONLY WHEN EAGLE METAL CONNECTORS ARE USED. TrueBuild® Truss Software v5.6.429.2 Eagle Metal Products 11-6-0 2-0-0 4-9-0 4-9-0 4-9-0 9-6-0 0-0-0 4-9-0 4-9-0 4-9-0 9-6-0 0-0-0 2- 4 - 9 2- 0 - 1 3 0- 5 - 1 3 2 12 6 14x6 - 24x4 / 31.5x3 | 43x4 -51.5x3 | All plates shown to be Eagle 20 unless otherwise noted. Loading (psf) TCLL : 20 TCDL : 13(rake) BCLL : 0 BCDL : 8 General Bldg Code : CBC 2022/ TPI 1-2014 Rep Mbr : Yes Lumber D.O.L. : 125 % CSI TC : 0.20 (1-2) BC : 0.27 (4-5) Web : 0.44 (2-4) Deflection L/ (loc) Allowed Vert TL: 0.09 in L / 999 (4-5) L / 240 Vert LL: 0.03 in UP L / 999 5 L / 360 Horz TL: 0.02 in 4 Reaction JT Brg Combo Brg Width Rqd Brg Width Max React Max Grav Uplift Max MWFRS UpliftMax C&C Uplift Max Uplift Max Horiz 1 1 5.5 in 1.50 in 533 lbs · -91 lbs -320 lbs -320 lbs 86 lbs 4 1 1.5 in --- 383 lbs · -53 lbs -173 lbs -173 lbs · Material Bracing TC: DFL #2 2 x 6 TC: Sheathed or Purlins at 6-3-0, Purlin design by Others. BC: DFL #2 2 x 4 BC: Sheathed or Purlins at 10-0-0, Purlin design by Others. Web: SPF Stud 2 x 4 Loads 1) This truss has been designed for the effects due to non-concurrent 10 psf bottom chord live load plus dead loads. 2) This truss has been designed for the effects of wind loads in accordance with ASCE7 - 16 with the following user defined input: 110 mph (Factored), Exposure C, Enclosed, Gable, Risk Category II, h=B=L=10 ft, Not End Zone Truss, Both end webs considered. DOL = 1.60 3) Non-concurrent minimum storage attic loading has been applied in accordance with IBC 1607.1 4) A 300 lbs moving/sprinkler point load (distributed over three trusses) has been applied to the TC concurrent with other dead loads. Member Forces Table indicates: Member ID, max CSI, max axial force, (max compr. force if different from max axial force). Only forces greater than 300lbs are shown in this table. TC 1-2 0.197 -946 lbs BC 4-5 0.266 914 lbs (-331 lbs)5-1 0.206 914 lbs (-331 lbs) Web 2-4 0.435 -931 lbs Notes 1) Unless noted otherwise, do not cut or alter any truss member or plate without prior approval from a Professional Engineer. 2) This truss has been designed using the green service reduction factors. 3) The fabrication tolerance for this roof truss is 20 % (Cq = 0.80). 4) Hanger is for graphical interpretation only. Install hanger per manufacturer's recommendation. 5) Brace bottom chord with approved sheathing or purlins per Bracing Summary. 6) A creep factor of 2.00 has been applied for this truss analysis. 7) Listed wind uplift reactions based on MWFRS & C&C loading. 1197618 0005/0006 TrusPro Inc. 695 Obispo Street Guadalupe, CA 93434 Ph: (805)343-2555 Fax: (805)343-2377 Truss:2B2 Job: 7330M Date: 10/30/23 19:25:50 Page: 1 of 1 Notes: All connector plates to be Eagle 20 gauge unless otherwise noted SPAN PITCH QTY OHL OHR CANT L CANT R PLYS SPACING WGT/PLY 9-6-0 2 /12 5 2-0-0 0-0-0 0-0-0 0-0-0 1 24 in 43 lbs ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING ANY TRUSS BASED UPON THIS TRUSS DESIGN DRAWING ARE INSTRUCTED TO REFER TO ALL OF THE INSTRUCTIONS, LIMITATIONS AND QUALIFICATIONS SET FORTH IN THE EAGLE METAL PRODUCT'S DESIGN NOTES ISSUED WITH THIS DESIGN AND AVAILABLE FROM EAGLE UPON REQUEST. DESIGN VALID ONLY WHEN EAGLE METAL CONNECTORS ARE USED. TrueBuild® Truss Software v5.6.429.2 Eagle Metal Products 11-6-0 2-0-0 4-9-0 4-9-0 4-9-0 9-6-0 0-0-0 4-9-0 4-9-0 4-9-0 9-6-0 0-0-0 2- 4 - 9 2- 0 - 1 3 0- 5 - 1 3 2 12 6 14x6 - 24x4 / 31.5x3 | 43x4 -51.5x3 | All plates shown to be Eagle 20 unless otherwise noted. Loading (psf) TCLL : 20 TCDL : 13(rake) BCLL : 0 BCDL : 18 General Bldg Code : CBC 2022/ TPI 1-2014 Rep Mbr : Yes Lumber D.O.L. : 125 % CSI TC : 0.21 (1-2) BC : 0.38 (4-5) Web : 0.55 (2-4) Deflection L/ (loc) Allowed Vert TL: 0.14 in L / 778 (4-5) L / 240 Vert LL: 0.03 in UP L / 999 5 L / 360 Horz TL: 0.02 in 4 Reaction JT Brg Combo Brg Width Rqd Brg Width Max React Max Grav Uplift Max MWFRS UpliftMax C&C Uplift Max Uplift Max Horiz 1 1 5.5 in 1.50 in 626 lbs · -34 lbs -264 lbs -264 lbs 86 lbs 4 1 1.5 in --- 480 lbs · · -115 lbs -115 lbs · Material Bracing TC: DFL #2 2 x 6 TC: Sheathed or Purlins at 6-3-0, Purlin design by Others. BC: DFL #2 2 x 4 BC: Sheathed or Purlins at 10-0-0, Purlin design by Others. Web: SPF Stud 2 x 4 Loads 1) This truss has been designed for the effects due to non-concurrent 10 psf bottom chord live load plus dead loads. 2) This truss has been designed for the effects of wind loads in accordance with ASCE7 - 16 with the following user defined input: 110 mph (Factored), Exposure C, Enclosed, Gable, Risk Category II, h=B=L=10 ft, Not End Zone Truss, Both end webs considered. DOL = 1.60 3) Non-concurrent minimum storage attic loading has been applied in accordance with IBC 1607.1 4) A 300 lbs moving/sprinkler point load (distributed over three trusses) has been applied to the TC concurrent with other dead loads. Member Forces Table indicates: Member ID, max CSI, max axial force, (max compr. force if different from max axial force). Only forces greater than 300lbs are shown in this table. TC 1-2 0.205 -1,192 lbs BC 4-5 0.382 1,156 lbs (-186 lbs)5-1 0.309 1,156 lbs (-186 lbs) Web 2-4 0.551 -1,178 lbs Notes 1) Unless noted otherwise, do not cut or alter any truss member or plate without prior approval from a Professional Engineer. 2) This truss has been designed using the green service reduction factors. 3) The fabrication tolerance for this roof truss is 20 % (Cq = 0.80). 4) Hanger is for graphical interpretation only. Install hanger per manufacturer's recommendation. 5) Brace bottom chord with approved sheathing or purlins per Bracing Summary. 6) A creep factor of 2.00 has been applied for this truss analysis. 7) Listed wind uplift reactions based on MWFRS & C&C loading. 1197618 0006/0006