HomeMy WebLinkAboutA - Project Plans (786-778 Higuera Street)PROJECT SITE
HIGU
E
R
A
S
T
.
C
H
O
R
R
O
S
T
.
10
1
F
R
E
E
W
A
Y
SAN LUIS OBISPO
MISSION
SAN LUIS OBISPO
CREEK
N
782 & 786 HIGUERA ST.,
778 HIGUERA ST.
PROJECT SITE
N
SLOMA - EXTERIOR IMPROVEMENTS
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401 APN: 002-243-041 AND 002-243-049 MARCH 30, 2026
T-1TITLE SHEET
2803-07-PS25
SLOMA - EXTERIOR IMPROVEMENTS
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401 APN: 002-243-041 AND 002-243-049
ZONING MAP
VICINITY MAP
PLANNING REGULATION
CITY OF SAN LUIS OBISPO
PROJECT DIRECTORY
ADDRESS:
CONTACT:
EMAIL:
SAN LUIS OBISPO MUSEUM OF ART
1010 BROAD ST.
SAN LUIS OBISPO, CA 93401
P:(805) 543-8562
APPLICANT
LEANN STANDISH
LSTANDISH@SLOMA.ORG
ADDRESS:
CONTACT:
EMAIL:
RRM DESIGN GROUP
3765 S. HIGUERA STREET, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 903-1230
ARCHITECT
DAVID GIBBS
GPGIBBS@RRMDESIGN.COM
ADDRESS:
CONTACT:
EMAIL:
RRM DESIGN GROUP
3765 S. HIGUERA STREET, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 903-1213
LANDSCAPE
ARCHITECT
LIEF MCKAY
LMCKAY@RRMDESIGN.COM
PARKING INFORMATION
ALLOWABLE BUILDING HEIGHT (TABLE 504.3 )
GENERAL BUILDING INFORMATION - ALLOWED (EACH BUILDING)
(BASED ON THE 2022 CBC )
ALLOWABLE NUMBER OF STORIES (TABLE 504.4 )
ALLOWABLE BUILDING AREA PER STORY (TABLE 506.2 )
TOTAL ALLOWABLE BUILDING AREA (TABLE 506.2 )
CONSTRUCTION TYPE (TABLE 601 )
OCCUPANCY CLASIFICATION (SEC. 302.1)
V-B
60'-0"
3
NO CHANGE TO (E)
NO CHANGE TO (E)
A-2, A-3, B, M, S
PROJECT INFORMATION
SITE INFORMATION:
APN:
STREET ADDRESS:
ZONING:
LOT SIZE:
LAND USE:
EXISTING USE:
PROPOSED USE:
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401
002-243-041 AND 002-243-049
C-D-H
DOWNTOWN COMMERCIAL
22,000 SF (.51 AC) AND 11,761 SF (.27 AC)
CULTURAL INSTITUTION AND GENERAL RETAIL
EATING & DRINKING AND GENERAL RETAIL
MAXIMUM FAR:
FLOOR AREA RATIO
PROPOSED FAR:
LOT COVERAGE
BUILDING:
HARDSCAPE/PAVING:
LANDSCAPE:
SETBACKS
3.0
NO CHANGE TO (E)
NO CHANGE TO (E)
4,138 SF
470 SF
NO REQUIRED OR PROPOSED SETBACKS
ADDRESS:
CONTACT:
EMAIL:
RRM DESIGN GROUP
3765 S. HIGUERA STREET, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 459-5882
CIVIL
ENGINEER
JESSE WILSON
JEWILSON@RRMDESIGN.COM
PROPOSED OCCUPANCY
PROPOSED CONSTRUCTION TYPE
PROPOSED BUILDING HEIGHT
GENERAL BUILDING INFORMATION - PROPOSED
A-2, A-3, B, M, S
V-B, NO CHANGE TO (E)
30'-0"
2, NO CHANGE TO (E)PROPOSED NUMBER OF STORIES
NOTE: ANY ADDITIONAL PLUMBING FIXTURES CALCULATED FROM THE CHANGE IN
EXTERIOR OCCUPANCY WILL BE ACCOMMODATED VIA TENANT IMPROVEMENT.
GENERAL
T-1 TITLE SHEET
ARCHITECTURAL
A-1 ARCHITECTURAL SITE PLAN
A-2 DEMOLITION FLOOR PLAN - FOR REFERENCE ONLY
A-3 EXTERIOR ELEVATIONS
A-4 EXTERIOR PERSPECTIVES
A-5 COLORS AND MATERIALS BOARD
A-6 DETAIL VIGNETTES
CIVIL
C-201.EXISTING CONDITIONS & SITE PREPARATION PLAN
C-301.GRADING AND DRAINAGE
C-501.EROSION CONTROL PLAN
C-502.EROSION CONTROL NOTES
C-601.DETAILS
LANDSCAPE
L-001.CREEK AND DECK AREA EXHIBIT
L-002.TREE PROTECTION MEMO
L-100.LANDSCAPE TREE PROTECTION PLAN
L-101.LANDSCAPE CONSTRUCTION PLAN
L-102.LANDSCAPE CONSTRUCTION DETAILS
L-103.LANDSCAPE CONSTRUCTION DETAILS
L-201.LANDSCAPE SITE SECTION
L-301.MATERIALS AND PLANT PALETTE
L-400.IRRIGATION SCHEDULE, NOTES, AND MWELO CALCULATIONS
L-401.IRRIGATION PLAN
L-402.IRRIGATION DETAILS
L-500.PLANTING DETAILS AND NOTES
L-501.PLANTING PLAN
STRUCTURAL
S-241.SLOMA DECK FOUNDATION PLAN - FOR REFERENCE ONLY
S-242.SLOMA DECK FRAMING PLAN - FOR REFERENCE ONLY
S-243.DECK DETAILS - FOR REFERENCE ONLY
TOTAL: 28
SHEET INDEX
1.
2.
3.
4.
PARKING NOTES:
MINIMAL SQUARE FOOTAGE ADDED TO INTERIOR TO ALLOW THE PROPOSED
FACADE TO MATCH ORIGINAL EXTERIOR FACADE LOCATION, STACKING OVER
BASEMENT PERIMETER WALL.
BOTH THE EXISTING AND PROPOSED INTERIOR OCCUPANCY AND USE ARE
GENERAL RETAIL, EATING AND DRINKING ESTABLISHMENTS, AND INDOOR
STORAGE OF NON-HAZARDOUS MATERIALS. THE PROPOSED TENANT
IMPROVEMENT ADDS CULTURAL INSTITUTION OCCUPANCY AND USE.
THE PROPOSED PROJECT HAS MINIMAL DECREASE OF INTERIOR BUILDING
SQUARE FOOTAGE (1.2% DECREASE) AND IS A NET DECREASE IN OCCUPANCY
QUANTITY AND THUS SHOULD NOT TRIGGER NEW PARKING REQUIREMENTS FOR
THE INTERIOR SPACE"
IF THE CITY CONSIDERS THE EXTERIOR PATIO EXTENSION AS SQUARE FOOTAGE
TO BE PARKED (NET OCCUPANCY WHEN EXTERIOR PATIO IS INCLUDED IS ONLY
AN INCREASE OF 5 OCCUPANTS), THEN WE WOULD SEE THE FOLLOWING:
•
•
PER SLO MUNICIPAL CODE 17.72.030:
D.2: FOR EATING AND DRINKING ESTABLISHMENTS, THEATERS, CULTURAL
INSTITUTIONS, PUBLIC ASSEMBLY FACILITIES, AND RELIGIOUS ASSEMBLY
FACILITIES: ONE-HALF THAT REQUIRED IN TABLE 3-4: PARKING REQUIREMENTS
BY USE; PROVIDED, HOWEVER, THAT IN NO CASE SHALL THE REQUIREMENT
EXCEED ONE SPACE PER THREE HUNDRED FIFTY SQUARE FEET OF GROSS
FLOOR AREA.
D.5: FOR EXISTING BUILDINGS, ONLY THE PARKING NEEDED FOR ADDITIONS
THERETO OR FOR CHANGES IN OCCUPANCY WHICH INCREASE PARKING
REQUIREMENTS RELATIVE TO PRIOR USES SHALL BE REQUIRED.
REQUIREMENTS:
GENERAL RETAIL: 1:300 X 1/2 = 1 SPACE PER 600 GSF
EATING AND DRINKING: 1:100 X 1/2 = 1 SPACE/200 GSF, HOWEVER 1 SPACE PER 350
GSF MAXIMUM REQUIREMENT IN C-D ZONE
INDOOR STORAGE: 1 SPACE PER 1500 GSF
CULTURAL INSTITUTION: 1:400 X 1/2 = 1 SPACE PER 800 GSF
•
•
•
•
•
•
•
EXISTING PARKING STATISTICS:
EXISTING GENERAL RETAIL GROSS BUILDING AREA: 7,455 GSF
EXISTING EATING AND DRINKING GROSS BUILDING AREA: 6,518 GSF
EXISTING INDOOR STORAGE GROSS BUILDING AREA: 3,904 GSF
REQUIRED PARKING FOR GENERAL RETAIL: 13 SPACES
REQUIRED PARKING FOR EATING AND DRINKING: 19 SPACES
REQUIRED PARKING FOR INDOOR STORAGE : 3 SPACES
TOTAL REQUIRED PARKING (EXISTING): 35 SPACES
PROPOSED PARKING STATISTICS:
PROPOSED GENERAL RETAIL GROSS BUILDING AREA: 3,755 GSF
PROPOSED EATING AND DRINKING* GROSS BUILDING AREA: 3,494 GSF
PROPOSED INDOOR STORAGE GROSS BUILDING AREA: 1,977 GSF
PROPOSED CULTURAL INSTITUTION GROSS BUILDING AREA: 7,431 GSF
REQUIRED PARKING FOR GENERAL RETAIL: 7 SPACES
REQUIRED PARKING FOR EATING AND DRINKING*: 10 SPACES
REQUIRED PARKING FOR INDOOR STORAGE : 2 SPACES
REQUIRED PARKING FOR CULTURAL INSTITUTION: 10 SPACES
TOTAL REQUIRED PARKING (PROPOSED): 29 SPACES
*PATIO TO BE USED FOR BOTH EXHIBITS AND EATING/DRINKING. PARKING COUNT
CALCULATED BASED ON STRICTER REQUIREMENT - EATING/DRINKING.
NET CHANGE IN REQUIRED PARKING SPACES: -6 SPACES
PARKING CALCULATIONS
1
A-3
2
A-3
PATIO HI
G
U
E
R
A
S
T
R
E
E
T
SAN
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
WICKENDEN BUILDING
THE WARDEN BLOCK
JOHNSON BUILDING
(E) PARKING LOT
(E
)
L
O
A
D
I
N
G
Z
O
N
E
(E
)
B
I
K
E
L
A
N
E
(NOT IN SCOPE)(NOT IN SCOPE)
(NOT IN SCOPE)
JOHNSON BUILDING
002-243-049
NETWORK BUILDING
002-243-041
SCOPE OF EXTERIOR
IMPROVEMENTS
SCOPE OF EXTERIOR IMPROVEMENTS
SCOPE OF
EXTERIOR
IMPROVEMENTS
73'
-
4
"
+
/
-
14'
-
0
"
+
/
-
(NOT IN SCOPE)
ED
G
E
O
F
CR
E
E
K
B
A
N
K
ED
G
E
O
F
CR
E
E
K
B
A
N
K
(NOT IN SCOPE)
DECK EXPANSION OVER
CREEK REQUIRES A CREEK
SETBACK EXCEPTION AND
IS SUBJECT TO DIRECTOR-
LEVEL PUBLIC HEARING
(INTERNAL TENANT IMPROVEMENT PLANS NOT PART OF ENTITLEMENT REVIEW)
(INTERNAL TENANT IMPROVEMENT PLANS NOT PART OF ENTITLEMENT REVIEW)
EA
S
E
M
E
N
T
8' -
0
"
A
C
C
E
S
S
EA
S
E
M
E
N
T
8'
-
0
"
A
C
C
E
S
S
SCOPE OF EXTERIOR
IMPROVEMENTS
P.L.
P.L.
P.L.
SLOMA - EXTERIOR IMPROVEMENTS
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401 APN: 002-243-041 AND 002-243-049 MARCH 30, 2026
A-1ARCHITECTURAL SITE PLAN
2803-07-PS25
SCALE: 1/8" = 1'-0"1 PROPOSED SITE PLAN
S1S1
T9
T9
T8
T8
T7
T7
T6
T6
T5
T5
T4
T4
T3
T3
T2
T2
T1
T1
S4S4
S2S2
S3S3
S6S6
S5S5
NOT PART OF DEMOLITION EVALUATION SINCE 778 HIGUERA ST. BUILDING DOES NOT HAVE A HISTORIC STATUS
NON-HISTORIC FULL-
GLASS FACADE TO BE
RECONSTRUCTED TO
MATCH ORIGINAL
STOREFRONT DESIGN18
'
-
1
1
1
/
2
"
+
/
-
NE
W
D
E
M
O
13
'
-
2
"
+
/
-
1'
-
6
"
+
/
-
4'
-
9
1
/
2
"
+
/
-
18
'
-
6
5
/
8
"
+
/
-
3'
-
6
"
+
/
-
98' - 4 1/4" +/-4' - 7" +/-
4' - 2 3/16" +/-
NEW INFILL
5' - 0" +/-
12' - 4 13/16" +/-
NEW INFILL
8' - 0" +/-
NEW DEMO
7' - 10" +/-
30' - 2" +/-
NEW DEMO
9' - 4"
24' - 7 75/256" +/-
22
'
-
0
5
/
8
"
+
/
-
NEW DEMO
38' - 6"
T9.1
T9.1
T8.1
T8.1
T8.2
T8.2
A-2DEMOLITION FLOOR PLAN - FOR REFERENCE ONLY
2803-07-PS25 12/17/2025
SLOMA - TENANT IMPROVEMENT
778-786 HIGUERA ST. SAN LUIS OBISPO, CA 93401
SCALE: 3/16" = 1'-0"1 DEMOLITION FLOOR PLAN - FOR REFERENCE ONLY
SUMMARY OF DEMOLITION
DEMOLITION
TOTAL WALL
LENGTH (LF)
INFILL
REPLACE
% OF MASONRY
WALL LENGTH (LF)
EXISTING 100%
13' - 0"
19' - 0"
51' - 3"
388' - 10"
13.1%
4.9%
3.3%
GROUND LEVEL
0' - 0"GALLERY 4 LOWER
0' - 10"
GALLERY 4 UPPER
1' - 3"
PROPOSED MAX HEIGHT
30' - 0"
PROPOSED MAX HEIGHT
30' - 0"
(E) T.O. STOREFRONT
16' - 4"
NETWORK BUILDING SCOPE AT JOHNSON BUILDING
PROPOSED SIGNAGE AREA
PROPOSED MARQUEE AREA
STOREFRONT RESTORATION
TO MATCH ADJACENT
EXISTING FACADE
(50' - 0" ALLOWED)(50' - 0" ALLOWED)
3' - 9" +/-12' - 0"2' - 8"20' - 6"2' - 8"11' - 7"3' - 9" +/-
11' - 7"
13
'
-
9
1
/
2
"
T
.
O
.
S
T
O
R
E
F
R
O
N
T
2'
-
4
"
7'
-
8
"
2'
-
0
"
1'
-
6
"
2'
-
8
1
/
2
"
9'
-
1
1
1
/
2
"
1'
-
6
"
2'
-
4
"
5' - 7 1/4" V.I.F.
1' - 1" V.I.F.
7' - 3" V.I.F.
1' - 1" V.I.F.
4' - 8" V.I.F.
5'
-
6
"
V
.
I
.
F
.
10
'
-
1
0
"
V
.
I
.
F
.
7'
-
6
"
METAL BUILDING ADDRESSING UNDER
SEPARATE SUBMITTAL PAINTED BUILDING ADDRESSING UNDER SEPARATE SUBMITTAL
DECORATIVE SIGNAGE BRACKET
TO MATCH ADJACENT, UNDER A
SEPARATE SUBMITTAL
GROUND LEVEL
0' - 0"GALLERY 4 LOWER
0' - 10"
GALLERY 4 UPPER
1' - 3"
PROPOSED MAX HEIGHT
30' - 0"
PROPOSED MAX HEIGHT
30' - 0"
(NO CHANGES PROPOSED)
NETWORK BUILDINGJOHNSON BUILDING
(50' - 0" ALLOWED)(50' - 0" ALLOWED)
SCOPE OF EXTERIOR FACADE IMPROVEMENTS -
NEW STOREFRONT AND FRAME
MURAL SPACE
PERFORATED SCREEN PER LANDSCAPE
(E
)
2
3
'
-
0
"
+
/
-
V
.
I
.
F
.
(E
)
2
1
'
-
3
"
+
/
-
V
.
I
.
F
.
(E
)
5
"
+
/
-
V
.
I
.
F
.
(E
)
1
0
"
+
/
-
V
.
I
.
F
.
1' - 2"
12' - 1" +/- V.I.F.
1' - 2"
1'
-
2
"
12
'
-
6
"
+
/
-
V
.
I
.
F
.
56' - 10" +/-41' - 3 5/8" +/-
PAINTED BUILDING
ADDRESSING UNDER
SEPARATE SUBMITTAL
METAL BUILDING
ADDRESSING
UNDER SEPARATE
SUBMITTAL
METAL BUILDING
ADDRESSING UNDER
SEPARATE SUBMITTAL
SLOMA - EXTERIOR IMPROVEMENTS
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401 APN: 002-243-041 AND 002-243-049 MARCH 30, 2026
A-3EXTERIOR ELEVATIONS
2803-07-PS25
SCALE: 3/16" = 1'-0"1 PROPOSED ELEVATION - HIGUERA ST.
SCALE: 3/16" = 1'-0"2 PROPOSED ELEVATION - REAR
SLOMA - EXTERIOR IMPROVEMENTS
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401 APN: 002-243-041 AND 002-243-049 MARCH 30, 2026
A-4EXTERIOR PERSPECTIVES
2803-07-PS25
A
A
A H H
J J
K
B
E
E
E
D
L
F
30' - 3" +/-
4'
-
7
"
+
/
-
S6
L
L
G
G
G
G
G
A
EPERFORATED SCREEN
PER LANDSCAPE
C
C
SLOMA - EXTERIOR IMPROVEMENTS
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401 APN: 002-243-041 AND 002-243-049 MARCH 30, 2026
A-5COLORS AND MATERIALS BOARD
2803-07-PS25
THINSET BRICK VENEER
RED BRICK, VARYING THICKNESS
MATCH GENERAL SHALE
"SCHOOLHOUSE" COLOR
EXTERIOR-GRADE TILE (JOHNSON ONLY)
4"X4" HUES OF GREEN TILE ACCENT,
ARCHITESSA - MODEL PEPPY IN ZESTY
COLOR SCHEME, OR SIMILAR (TILE AND
GROUT TO MATCH EXISTING JOHNSON
BUILDING TILE COLOR)
DECORATIVE PARAPET CAP (NETWORK ONLY)
SANTA BARBARA FINISH STUCCO OVER FOAM
SHERWIN WILLIAMS 0055 - LIGHT FRENCH GRAY
OR SIMILAR
STOREFRONTS
DARK-BRONZE, ANODIZED ALUMINUM
FRAMES
LOW-E CLEAR GLAZING
EXTERIOR-GRADE TILE (JOHNSON ONLY)
2"X2" RED TILE ACCENT,
DALTILE - D017 OR APPROVED SIMILAR
(TILE AND GROUT TO MATCH EXISTING
JOHNSON BUILDING TILE COLOR)
PAINTED FINISH (JOHNSON ONLY)
MATCH (E) JOHNSON BUILDING COLOR
AND SHEEN
SCALE: 3/16" = 1'-0"1 PARTIAL ELEVATION - HIGUERA ST.
SCALE: 1/4" = 1'-0"2 PARTIAL ELEVATION - REAR
JHA
K
B
E
D
COLOR AND MATERIALS - NETWORK AND PATIO FACADES COLOR AND MATERIALS - JOHNSON FACADE
JOHNSON BUILDING FACADE - FOR REFERENCE
H
G
WINDOW FRAMES (JOHNSON ONLY)
ANODIZED ALUMINUM FRAMES
LOW-E CLEAR GLAZING
COLOR TO BE DARK GREEN TO MATCH (E)
L
K
JMETAL PANEL "PORTAL"
ANODIZED METAL
MATCH COLOR OF STOREFRONT FRAME
C
MARQUEE SIGNAGE*
BLACK ANODIZED ALUMINUM
F
METAL SIGNAGE*
WHITE ANODIZED ALUMINUM
ILLUMINATED BY SCONCES ONLY
ACCENT TRIM - STOREFRONTS
AND BULKHEADS
PRECAST CONCRETE
G
*ALL SIGNAGE IS TO BE A SEPARATE PERMIT SUBMITTAL BY OWNER, SIGNAGE HERE IS SHOWN FOR GRAPHIC PLACEHOLDER
FLOOD LIGHTS
WAC LIGHTING
WP-LED335 - COLOR TEMP 30
ARCHITECTURAL BRONZE
LIGHT FIXTURES - BUILDING AND LANDSCAPE
S1 S2
TAPE LIGHTS
QTL LIGHTING
VERS-06-SW, 30 CCT
NO EXTERNAL LOUVER
SEE LANDSCAPE
S3
STRING LIGHTS
TIVOLI LIGHTING
LITESPHERE ADAPT 2.0
BLACK STRINGING
SEE LANDSCAPE
UPLIGHTING
WAC LIGHTING
HORNET ACCENT 12V -
COLOR TEMP 30
BRONZE
S4S5
MURAL LIGHTS
HYDREL
4750LCR LINEAR CONTINUOUS RUN
WALL WASH, 30K TEMP.
DESIGNER BRONZE SMOOTH
S6
SIGNAGE LIGHTS
HINKLEY
FORGE 12078BK
MEDIUM LED
BURNISHED BRONZE
S7
CAN LIGHTS
LITHONIA LIGHTING
LDN6 STATIC WHITE
COLOR TEMP. 30 / 750 LUMENS
DOWNLIGHT TRIM, CLEAR, MATTE DIFFUSE
WHITE PAINTED FLANGE
SLOMA - EXTERIOR IMPROVEMENTS
778-786 HIGUERA ST. SAN LUIS OBISPO, CA, 93401 APN: 002-243-041 AND 002-243-049 MARCH 30, 2026
A-6DETAIL VIGNETTES
2803-07-PS25
METAL VENEER
FRAME, WRAP ALL
EXPOSED EDGES
PERFORATED SCREEN
IN FRONT OF
ELECTRICAL PANELS,
PER LANDSCAPE
RECESSED CAN LIGHTS
ALUMINUM STOREFRONT
AND GLAZING. MATCH
EXISTING OPENING SIZE
EXISTING WINDOWS
DUAL-DIRECTION
DOUBLE STOREFRONT
DOOR
GRAY SANTA BARBARA
TROWEL FINISH STUCCO
OVER CUSTOM FOAM SHAPE
EXTERIOR SCONCES
CUSTOM FABRICATED
ALUMINUM SIGNAGE*
BAND OF STANDARD BRICK,
MATCH BRICK VENEER
THINSET BRICK VENEER
EXISTING STANDARD
BRICK EXTERIOR WALLS
THINSET BRICK VENEER
REDUCED-DEPTH THINSET
BRICK VENEER
PRECAST CONCRETE
SILL BAND, SLOPED
PRECAST CONCRETE SILL BAND
AT SIDEWALK, SLOPED
ALUMINUM STOREFRONT
AND GLAZING.
THINSET BRICK VENEER
PRECAST CONCRETE
SILL BAND, SLOPED
CUSTOM FABRICATED
ALUMINUM MARQUEE
SIGNAGE*, EACH SIDE
PRECAST CONCRETE BAND
WOOD-LOOK METAL
PLANK SOFFIT
THINSET BRICK VENEER
PRECAST CONCRETE
SILL BAND, SLOPED
PRECAST CONCRETE SILL BAND
AT SIDEWALK, SLOPED
ALUMINUM STOREFRONT
AND GLAZING.
DOUBLE STOREFRONT
DOOR
RECESSED CAN LIGHTSDETAIL VIGNETTE - STOREFRONT AT JOHNSON REAR
DETAIL VIGNETTE - BULKHEAD AT NETWORK
DETAIL VIGNETTE - BUILDING SIGNAGE
DETAIL VIGNETTE - MUSEUM ENTRY
(E) ELECTRICAL
PANELS TO REMAIN,
BEYOND
*ALL SIGNAGE IS TO BE A SEPARATE PERMIT SUBMITTAL BY OWNER, SIGNAGE HERE IS SHOWN FOR GRAPHIC PLACEHOLDER
*ALL SIGNAGE IS TO BE A SEPARATE PERMIT SUBMITTAL BY OWNER, SIGNAGE HERE IS SHOWN FOR GRAPHIC PLACEHOLDER
EB
SA
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
LANDSCAPE
EASEMENT PER
1569/OR/565
CREEK MAINTENANCE
EASEMENT PER 41/PM/72
WALKWAY EASEMENT
PER 1569/OR/565
N3
4
°
5
0
'
5
3
"
W
2
5
0
.
2
2
'
N3
3
°
4
7
'
2
3
"
W
7
1
.
3
7
'
N84°32'00"E 5.33'
N2
2
°
1
6
'
3
1
"
W
6
2
.
0
0
'
N3
4
°
4
8
'
5
4
"
W
2
1
9
.
8
0
'
N56°12'37"E 70.00'
REMOVE EXISTING
BRICK SEAT WALL
REMOVE EXISTING
BRICK SEAT WALL
AND CONCRETE
PAD.
PROTECT EXISTING
CONCRETE WALL
REMOVE EXISTING
BRICK FLATWORK UP
TO BOTTOM RISER.
PROTECT EXISTING
CONCRETE STAIRS
PROTECT EXISTING
CONCRETE BANDING
REMOVE EXISTING
RED BRICK. STORE
REDBRICK FOR REUSE.
REMOVE EXISTING
RED BRICK. STORE
REDBRICK FOR REUSE.
REMOVE EXISTING
BRICK PAD
REMOVE EXISTING
CONCRETE PAD
REMOVE ALL
EXISTING CONCRETE
BANDING, U.O.N.
PROTECT EXISTING WALL
PROTECT
EXISTING
BUILDING
PROTECT EXISTING WALL MOUNTED
ELECTRICAL EQUIPMENT
REMOVE
EXISTING TREE
PROTECT
EXISTING
BUILDING
REMOVE
EXISTING TREE
PROTECT EXISTING
CONCRETE PAD
PROTECT
EXISTING
BUILDING
REMOVE
EXISTING TREE
PROTECT
EXISTING TREE
PROTECT
EXISTING
TREE
REMOVE EXISTING
BRICK WALL
200
20
0
20
0
20
5
196
197
1
9
8
1
9
9
20
1
20
2
20
3
20
4
20
0
19
8
19
9
20
1
202
203
19
0
18
9
19
1
19
5
20
0
196
197
1
9
8
19
9
20
1
202
20
5
203
20
4
204
204
204
20
5
20
6
2
0
4
204
2
0
5
204
2
0
4
PROTECT EXISTING TREE. REFER
TO TREE PROTECTION PLAN
FOR ALL WORK AROUND
EXISTING TREES, TYP.
REMOVE EXISTING
TREE STUMP
PROTECT
EXISTING
TREE
PROTECT
EXISTING
TREES
PROTECT
EXISTING
TREES
PROTECT
EXISTING
SHRUBS
REMOVE EXISTING
CONCRETE PAD
SAWCUT
SAWCUT
REMOVE EXISTING
BRICK WALL
REMOVE EXISTING
BRICK WALL
SAWCUT
SAWCUT BRICK WALL AT
THIS LOCATION. SALVAGE
WHOLE BRICKS WHERE
POSSIBLE FOR PATCHBACK.
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^
^^
HORIZONTAL
SAWCUT REMOVE EXISTING
LIGHT POST
PROTECT
EXISTING WALL
PROTECT
EXISTING
WALL
CONTRACTOR TO VERIFY
NO PIPE DRAINS TO
CATCH BASIN AND
REMOVE EXISTING
CATCH BASIN.
PROTECT EXISTING
ROOF DOWNSPOUT
PROTECT EXISTING
ROOF DOWNSPOUT
PROTECT EXISTING
ELECTRICAL BOX
REMOVE
EXISTING
BACKFLOW
PREVENTER
PROTECT EXISTING
ROOF DRAIN
PROTECT EXISTING
ELECTRICAL
OUTLET AND
CLEANOUT
DEMO EXISTING GAS POC. PROPERLY
STUB AND CAP UNDERGROUND
REAR PATIO ALONG SAN LUIS OBISPO CREEK
VERTICAL SAW CUT FROM
TOP OF WALL TO MATCH
ELEVATION OF
HORIZONTAL SAW CUT.
END HORIZONTAL SAW
CUT OF WALL AT
ELEVATION 202.13. ENSURE
6" CLEARANCE BETWEEN
TOP OF WALL AND
BOTTOM OF DECK JOIST
REMOVE
EXISTING
TREE
VERTICAL SAW CUT FROM TOP
OF WALL TO MATCH ELEVATION
OF HORIZONTAL SAW CUT. BEGIN
HORIZONTAL SAW CUT OF WALL
AT ELEVATION 201.69. ENSURE 6"
CLEARANCE BETWEEN TOP OF
WALL AND BOTTOM OF DECK
JOIST.
REMOVE EXISTING
WOOD WALL
REMOVE
EXISTING
TREE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
INSTALL TREE
PROTECTION
FENCING
HORIZONTAL SAW CUT OF WALL
SHALL BE 18.5" BELOW PROPOSED
FS OF PATIO. ENSURE 6"
CLEARANCE BETWEEN NEW TOP
OF EXITING WALL AND BOTTOM
OF DECK JOIST. ENSURE NEW TOP
OF EXISTING WALL IS SLOPED 2%
TOWARDS SAN LUIS OBISPO
CREEK TO PROMOTE DRAINAGE.REMOVE EXISTING
WOOD PRIVACY WALL
CAREFULLY HAND DEMOLISH BRICK WALL AND/OR
PAVING WITHIN CRITICAL ROOT ZONE TO EXPOSE
ROOT SYSTEM UNDER SUPERVISION OF PROJECT
ARBORIST. PROJECT ARBORIST TO ASSESS CURRENT
CONDITION AND LOCATION OF EACH STRUCTURALLY
SIGNIFICANT ROOT THAT MAY BE IMPACTED BY
PROPOSED CONDITIONS. NO ROOT PRUNING SHALL
OCCUR UNLESS DIRECTED BY PROJECT ARBORIST.
#3
#5
#7#8
#9
#10
#11
#12
#13
#14
EB
EB
EB
EB
EB
COWM
EB
EB
GMGM
VAULT
VAULT
EB
EXISTING VAULT TO
BASEMENT
PROTECT EXISTING
GAS METER
PROTECT EXISTING TREE
PROTECT EXISTING
ELECTRICAL BOX
PROTECT EXISTING
ELECTRICAL BOX
PROTECT EXISTING
ELECTRICAL VAULT
PROTECT EXISTING TREE
PROTECT EXISTING
GAS METER
STORE FRONT ALONG HIGUERA STREET
HIGUERA STREET
^^^
^
^
^
^
^^^^
^
^
^
^
SAWCUT AT NEAREST
EXPANSION JOINT
SAWCUT AT NEAREST
EXPANSION JOINT
SAWCUT AT
BACK OF CURB
SAWCUT AT NEAREST
EXPANSION JOINT
PROTECT EXISTING
CURB AND GUTTER PROTECT EXISTING
PAVING IN STREET
DEMO EXISTING SIDEWALK TO
NEAREST EXPANSION JOINT
PROTECT EXISTING
WATER METER BOX
PROTECT EXISTING
ELECTRICAL BOX
PROTECT EXISTING
ELECTRICAL BOX
PROTECT EXISTING
ELECTRICAL BOXPROTECT EXISTING
ELECTRICAL BOX
PROTECT PARKING
METER AND POLE
PROTECT PARKING
METER AND POLE
PROTECT PARKING
METER AND POLE
PROTECT PARKING
METER AND POLE
PROTECT PARKING
METER AND POLE
PROTECT PARKING
METER AND POLE
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
RAC
RACJW
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
C-201
EX
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
&
SI
T
E
P
R
E
P
A
R
A
T
I
O
N
P
L
A
N
0 feet10
1"=5'
5 15
NOTES:
1.ALL DEMOLITION WITHIN THE CRITICAL ROOT ZONE THAT
EXPOSES ROOT SYSTEMS SHALL BE UNDER THE
SUPERVISION OF A PROJECT ARBORIST AND SHALL
COMPLETED USING HAND TOOLS. PROJECT ARBORIST TO
ASSESS CURRENT CONDITION AND LOCATION OF EACH
STRUCTURALLY SIGNIFICANT ROOT THAT MAY BE
IMPACTED BY PROPOSED CONDITIONS. NO ROOT
PRUNING SHALL OCCUR UNLESS DIRECTED BY PROJECT
ARBORIST.
GRADING NOTES
DAYLIGHT STORMDRAIN, VIA 6" x 6" x6" TEE, INTO LEVEL SPREADER. SEE
DETAIL ON C-601.
INSTALL 12" x 12" NDS CATCH BASIN, OR APPROVED EQUAL, PER CATCH
BASIN DETAIL "C" ON SHEET C-601.
INSTALL 4" ATRIUM GRATE PER DETAIL 'B' ON SHEET C-601.
INSTALL 4" HDPE STORM DRAIN. (SLOPE = 0.5% MIN.)
INSTALL 6" HDPE STORM DRAIN. (SLOPE = 0.5% MIN.)
INSTALL 3" PERFORATED HDPE STORM DRAIN (SLOPE = 0.5% MIN.) PER
DETAIL "E" ON SHEET C-601 WHEN UNDER PAVERS. PER DETAIL 9 ON L-102
OR 8 ON L-102 WHEN LOCATED BEHIND A WALL.
INSTALL CLEANOUT PER DETAIL "D" ON SHEET C-601.
INSTALL PERMEABLE PAVERS PER LANDSCAPE DETAIL.
INSTALL MISSION STYLE SIDEWALK PER CITY STANDARD DETAIL 4110 AND
4220.
1
2
3
4
5
6
7
8
9
NOTES
1.CONTRACTOR SHALL PROVIDE ALL FITTINGS AND
APPURTENANCES REQUIRED TO CONSTRUCT UTILITIES AS SHOWN
ON SHEETS INCLUDED IN THESE PLANS.
2.THE SOILS REPORT, IN ITS ENTIRETY, GEOTECHNICAL ENGINEER
RECOMMENDATIONS AND ANY UPDATE LETTERS, SHALL BE
CONSIDERED A PART OF THESE PLANS.
3.PROVIDE INSTALLATION ELEVATION BY LICENSED SURVEYOR TO
PUBLIC WORKS DEPARTMENT, ENGINEERING DIVISION WITHIN 7
CALENDAR DAYS OF INSTALLATION.
//////
//
//
//
//
//
//
////
GB
GB
C
#3
#2
#1
#5
#4
#7#8
#9
#10
#11
#12
#13
#14
#6 (STUMP)
SD
S
D
SD
S
D
S
D
SD
S
D
SD
S
D
SD
S
D
SD
SD
S
D
SD
S
D
SD
S
D
SD
S
D
S
D
SD
S
D
SD
S
D
SD
S
D
SD
SD
S
D
SD
SD
SD
S
D
SD
S
D
SD
S
D
SD
S
D
SD
S
D
SD
SD
S
D
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
S
D
SD
S
D
SD
S
D
SD
5
%
M
A
X
5
%
M
A
X
2.
0
%
MA
X
2.
0
%
MA
X
2.
0
%
MA
X
2.
0
%
MA
X
2.
0
%
MA
X
REAR PATIO ALONG SAN LUIS OBISPO CREEK
2.0%
MAX
SA
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
LANDSCAPE EASEMENT PER
1569/OR/565
CREEK MAINTENANCE EASEMENT PER 41/PM/72
N3
4
°
5
0
'
5
3
"
W
2
5
0
.
2
2
'
N3
3
°
4
7
'
2
3
"
W
7
1
.
3
7
'
N84°32'00"E 5.33'
N2
2
°
1
6
'
3
1
"
W
6
2
.
0
0
'
N3
4
°
4
8
'
5
4
"
W
2
1
9
.
8
0
'
N56°12'37"E 70.00'
204.23
FS
204.22
FS
204.30
FS
204.23
FS
204.02
FS
203.96
FS
203.76
FS
203.73
FS
203.66
FS
203.57
FS
203.60
FS
203.23
FS
203.23
FS
203.63
FS
203.51
FS
203.43
FS
203.35
FS
203.27
FS
203.43
FS
203.51
FS
203.59
FS
204.30
FS
203.53
FS
203.55
FS203.58
FS
203.55
FS
203.55
FS
203.56
FS
203.47
FS
203.38
FS
203.35
FS
204.02
FS
204.09 FS
MATCH EX
204.58 FS
MATCH EX
203.55
FS
203.53
FS203.53
FS
203.53
FS
203.95
FS
204.02
FS
203.68
FS
201.72
INV
DISCHARGE SD UNDER
PROPOSED PATIO TO CREEK
201.15 INV
204.63 FS
204.23 FS
204.80 FS
204.28 FS
(1) RISER
204.75
FS
204.81
FS
204
20
4
20
0
19
8
19
9
201
202
203
2
0
0
19
7
1
9
8
1
9
9
19
5
20
0
1
9
6
19
7
19
8
19
9
20
1
202
204
2
0
4
204
20
5
203
20
4
2
0
3
20
4
WARDEN
BRIDGE
PARKING
LOT
WICKENDEN
BUILDING
204.80 TG
203.92 INV
204.30 TG
203.42 INV
203.50 TG
202.62 INV
DISCHARGE UNDER
PATIO TO CREEK
201.02 INV
201.54
WYE INV
202.25
WYE INV
CONNECT PERFORATED
PIPE TO SOLID PIPE
201.39 WYE INV
CONNECT PERORATED
PIPE TO SOLID PIPE
201.39 WYE INV
CLEANOUT
202.33 INV
CLEANOUT
201.67 INV
201.56
INV
204.72
FS
205.75 TW
HT=1.03'
205.75 TW
HT=2.39'
205.75 TW
HT=2.31'
205.75 TW
HT=2.19'
203.27
FS
203.35
FS
1
1
2
2
2
3
4
6
6
6
6
5
5
5
5
5
4
7
7
CONNECTION TO WARDEN
BRIDGE IS NOT ADA COMPLIANT
BEYOND THIS GRADE BREAK.
203.92
FS
205.80 TG
202.17 INV 2
CHANGE FROM SOLID TO
PERFORATED PIPE HERE
CORE DRILL THROUGH
WALL FOUNDATION
FOR SD OUTLET PIPE.
CORE DRILL THROUGH
WALL FOUNDATION
FOR SD OUTLET PIPE.
203.50
FS
203.61
FS
203.58
FS
8
8
8
204.93
EX TW
205.20
EX TW
205.75 TW
HT=2.10'
206.00 TW
HT=2.00'
206.00 TW
HT=2.32'
206.0
FG
206.0
FG
206.0
FG
206.0
FG
205.2
FG
205.2
FG
205.2
FG
205.2
FG
INSTALL A CAST IN PLACE CONCRETE
WALL DOWELED INTO THE EXISTING
BRICK WALL. APPLY RECYCLED BRICK
VENEER TO MATCH THE EXISTING
WALL. GROUT ALL INTERFACE SEAMS
BETWEEN NEW AND EXISTING
WALL/FINISH SURFACE TO PREVENT
WATER INTRUSION.
203.50 INV
MATCH IN KIND EX TOP
OF WALL ELEVATION
203.50 INV
204.5 TG
202.5 INV
6
6
6
202.06
INV
205.75 TW
HT=2.10'
205.75 TW
HT=1.68'
205.75 TW
203.66
EX FINISH
FLOOR
204.40
EX FINISH
FLOOR
204.05
FL
203.68 TG
201.75 INVEXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
203.35 TG
201.86 INV
203.31 TG
201.70 INV
203.41
FS / GB
203.51
FS / GB
203.41
FS / GB
203.42
FS / GB
203.61
FS
203.61
FS
203.37
FS / HP
203.39
FS / GB
203.45
FS / GB
203.42
FS / GB
EB
EB
EB
EB
EB
COWM
EB
EB
GMGM
VAULT
VAULT
EB
STORE FRONT ALONG HIGUERA STREET
HIGUERA STREET
^^^
^
^
^
^
^^^^
^
^
^
^
2.
0
%
MA
X
203.78 FS
MATCH EX
203.91 FS
MATCH EX
203.54 FS
MATCH EX
203.42 FS
MATCH EX
REMOVE EX VAULT LID, SLURRY FILL EXISTING VAULT, AND
INSTALL SIDEWALK PER CITY OF SLO STANDARD DETAIL 4110.
9
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
RAC
RACJW
NOT F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
0 feet10
1"=5'
5 15
C-301
GR
A
D
I
N
G
A
N
D
D
R
A
I
N
A
G
E
PROPOSED STATISTICS
(A) PROPOSED NEW PERVIOUS/IMPERVIOUS AREA
HARDSCAPE AREA (OFFSITE): 110 SF
HARDSCAPE AREA (ONSITE): 172 SF
REPURPOSED BRICK PAVERS AREA: 2049 SF
PERMEABLE PAVERS AREA: 778 SF
PERVIOUS DECK AREA: 1,101 SF
LANDSCAPE AREA: 495
//////
//
//
//
//
//
//
////
GB
GB
C
#3
#2
#1
#5
#4
#7#8
#9
#10
#11
#12
#13
#14
#6 (STUMP)
EB
SA
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
N3
4
°
5
0
'
5
3
"
W
2
5
0
.
2
2
'
N3
3
°
4
7
'
2
3
"
W
7
1
.
3
7
'
N84°32'00"E 5.33'
N2
2
°
1
6
'
3
1
"
W
6
2
.
0
0
'
N3
4
°
4
8
'
5
4
"
W
2
1
9
.
8
0
'
N56°12'37"E 70.00'
S
D
SD
S
D
S
D
SD
S
D
SD
S
D
SD
S
D
SD
SD
S
D
SD
S
D
SD
S
D
SD
SD
S
D
SD
S
D
SD
S
D
SD
S
D
S
D
SD
S
D
SD
S
D
SD
S
D
SD
SD
S
D
S
D
SD
S
D
SD
S
D
SD
SD
S
D
S
D
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
S
D
SD
S
D
SD
S
D
SD
204
20
4
SE-1
SE-1
SE-5
SE-7
SE-10
SE-10
WM-8
WM-1
2
0
0
196
197
1
9
8
1
9
9
20
1
20
2
SE-10
SE-10
REAR PATIO ALONG SAN LUIS OBISPO CREEK
SE-10
SE-10
SE-10
SE-10
EB
EB
EB
EB
EB
COWM
EB
EB
GMGM
VAULT
VAULT
EB
STORE FRONT ALONG HIGUERA STREET
HIGUERA STREET
SE-7
SE-7
SE-7
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
RAC
RACJW
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
SWPPP CONTROL BMP LEGEND
SILT FENCE
STRAW WATTLE
STREET SWEEPING/VACUUMING
STORM DRAIN INLET PROTECTION (SEE PHASING NOTES ON C-9.0)
STABILIZED CONSTRUCTION ENTRANCE WITH WHEEL WASH AREA
MATERIAL DELIVERY/STORAGE AREA
CONCRETE WASTE MANAGEMENT AREA
SE-1
SE-5
SE-7
SE-10
TC-1
WM-1
WM-8
SITE SPECIFIC BMP NOTES:
1. PERIMETER CONTROL BMP'S AND STABILIZED CONSTRUCTION ENTRANCES SHALL BE IN PLACE
PRIOR TO ANY GROUND DISTURBANCE.
2.THESE PLANS ARE INTENDED TO REPRESENT DIFFERENT PHASES DURING CONSTRUCTION. THE
CONTRACTOR SHALL IMPLEMENT THE BMP'S SHOWN AND/OR ANY OTHER MEASURES
NECESSARY DURING CONSTRUCTION TO BE IN COMPLIANCE WITH THE GENERAL PERMIT.
IMPLEMENTATION OF THE THE BMP'S SHOWN ON THESE PLANS DO NOT RELIEVE THE OWNER OR
HIS/HER REPRESENTATIVE FROM RESPONSIBILITY OF IMPLEMENTING ALL MEASURES NEEDED TO
BE IN COMPLIANCE.
3.THE CONTRACTOR SHALL USE CLASS II BASE FOR THE STABILIZED CONSTRUCTION ROADWAY OR
ALTERNATE METHODS THAT ACHIEVE THE DESIRED RESULTS. THIS BMP SHALL BE IMPLEMENTED TO
ALL BUILDING PADS PRIOR TO VERTICAL CONSTRUCTION, OR AS SOON AS PRACTICAL.
4.THE CONTRACTOR MAY UTILIZE RUMBLE PLATES IN LIEU OF RIP RAP AT THE CONSTRUCTION
ENTRANCES AS LONG AS THEY ACCOMPLISH THE DESIRED RESULTS.
5.ANY SEDIMENTS TRACKED OFFSITE SHALL BE CLEANED DAILY BY MEANS OF MOBILE STREET
SWEEPERS.
6.ANY GRADED AREAS THAT ARE GOING TO SIT IDLE FOR MORE THAN TWO WEEKS, SHALL HAVE
AN APPROPRIATE GROUND COVER BMP APPLIED.
7.THE LOCATIONS SHOWN FOR THE EQUIPMENT AND MATERIAL DELIVERY STORAGE AREAS AND
CONCRETE WASTE CLEANOUT MAY BE RELOCATED DURING CONSTRUCTION.
8.CLEANING STREETS AND SWEEPING MUST BE DONE AT THE END OF EACH WORK DAY TO THE
SATISFACTION OF THE PUBLIC WORKS INSPECTOR.
NOTE:
THE PROJECT AREA OF DISTURBANCE IS UNDER 1 ACRE AND IS
SUBSEQUENTLY EXEMPT FROM COVERAGE UNDER THE GENERAL PERMIT
FOR DISCHARGES OF STORM WATER ASSOCIATED WITH CONSTRUCTION
ACTIVITY CONSTRUCTION GENERAL PERMIT ORDER 2009-0009-DWQ.
CONTRACTOR'S NOTES:
1.CONTRACTOR SHALL PREVENT WATER CONTAMINATION DURING CONSTRUCTION BY
IMPLEMENTING THE FOLLOWING CONSTRUCTION SITE MEASURES:
A.ALL ENTRANCES/EXITS TO THE CONSTRUCTION SITE SHALL BE STABILIZED USING METHODS
DESIGNED TO REDUCE TRANSPORT OF SEDIMENT OFF SITE.
B.STABILIZING MEASURES MAY INCLUDE BUT ARE NOT LIMITED TO USE OF GRAVEL PADS, STEEL
RUMBLE PLATES, TEMPORARY PAVING, ETC.
C.ANY SEDIMENT OR OTHER MATERIALS TRACKED OFF SITE SHALL BE REMOVED THE SAME DAY
AS THEY ARE TRACKED USING DRY CLEANING METHODS.
D.ENTRANCES/EXITS SHALL BE MAINTAINED UNTIL GRADED AREAS HAVE BEEN STABILIZED BY
STRUCTURES, LONG-TERM EROSION CONTROL MEASURES OR LANDSCAPING.
E.APPLY CONCRETE, ASPHALT, AND SEAL COAT ONLY DURING DRY WEATHER.
F.COVER STORM DRAINS AND MANHOLES WITHIN THE CONSTRUCTION AREA WHEN PAVING
OR APPLYING SEAL COAT, SLURRY, FOG SEAL, ETC.
G.STORE, HANDLE AND DISPOSE OF CONSTRUCTION MATERIALS AND WASTE SUCH AS PAINT,
MORTAR, CONCRETE SLURRY, FUELS, ETC. IN A MANNER WHICH MINIMIZES THE POTENTIAL
FOR STORM WATER CONTAMINATION.
2.WITHIN 30 DAYS OF COMPLETION OF GRADING ACTIVITIES, CONTRACTOR SHALL USE
HYDRO-SEED, STRAW BLANKETS, GEOTEXTILE BINDING FABRICS OR OTHER P&D APPROVED
METHODS AS NECESSARY TO HOLD SLOPE SOILS UNTIL LANDSCAPE VEGETATION IS ESTABLISHED.
P&D MAY REQUIRE THE RESEEDING OF SURFACES GRADED FOR THE PLACEMENT OF STRUCTURES
IF CONSTRUCTION DOES NOT COMMENCE WITHIN 30 DAYS OF GRADING.
3.CONTRACTOR SHALL DESIGNATE A CONSTRUCTION EQUIPMENT FILLING AND STORAGE AREA(S)
TO CONTAIN SPILLS, FACILITATE CLEAN-UP AND PROPER DISPOSAL AND PREVENT
CONTAMINATION FROM DISCHARGING TO THE STORM DRAINS, STREET, DRAINAGE DITCHES,
CREEKS, OR WETLANDS. THE AREAS SHALL BE NO LARGER THAN 50 X 50 FOOT UNLESS
OTHERWISE APPROVED BY P&D AND SHALL BE LOCATED AT LEAST 100 FEET FROM ANY STORM
DRAIN, WATER BODY OR SENSITIVE BIOLOGICAL RESOURCES.
4.GRADING AND EROSION AND SEDIMENT CONTROL PLANS SHALL BE DESIGNED TO MINIMIZE
EROSION DURING CONSTRUCTION AND SHALL BE IMPLEMENTED FOR THE DURATION OF THE
GRADING PERIOD AND UNTIL RE-GRADED AREAS HAVE BEEN STABILIZED BY STRUCTURES,
LONG-TERM EROSION CONTROL MEASURES OR PERMANENT LANDSCAPING.
5.THESE MEASURES ARE REQUIRED FOR ALL PROJECTS INVOLVING EARTHMOVING ACTIVITIES
REGARDLESS OF THE PROJECT SIZE OR DURATION. PROPER IMPLEMENTATION OF THESE
MEASURES IS ASSUMED TO FULLY MITIGATE FUGITIVE DUST EMISSIONS. DURING CONSTRUCTION,
USE WATER TRUCKS OR SPRINKLER SYSTEMS TO KEEP ALL AREAS OF VEHICLE MOVEMENT DAMP
ENOUGH TO PREVENT DUST FROM LEAVING THE SITE. AT A MINIMUM, THIS SHOULD INCLUDE
WETTING DOWN SUCH AREAS IN THE LATE MORNING AND AFTER WORK IS COMPLETED FOR THE
DAY. INCREASED WATERING FREQUENCY SHOULD BE REQUIRED WHENEVER THE WIND SPEED
EXCEEDS 15 MPH. RECLAIMED WATER SHOULD BE USED WHENEVER POSSIBLE. HOWEVER,
RECLAIMED WATER SHOULD NOT BE USED IN OR AROUND CROPS FOR HUMAN CONSUMPTION.
MINIMIZE AMOUNT OF DISTURBED AREA AND REDUCE ON SITE VEHICLE SPEEDS TO 15 MPH OR
LESS. IF IMPORTATION, EXPORTATION AND STOCKPILING OF FILL MATERIAL IS INVOLVED, SOIL
STOCKPILED FOR MORE THAN TWO DAYS SHALL BE COVERED, KEPT MOIST, OR TREATED WITH
SOIL BINDERS TO PREVENT DUST GENERATION. TRUCKS TRANSPORTING FILL MATERIAL TO AND
FROM THE SITE SHALL BE TARPED FROM THE POINT OF ORIGIN. GRAVEL PADS SHALL BE
INSTALLED AT ALL ACCESS POINTS TO PREVENT TRACKING OF MUD ONTO PUBLIC ROADS. AFTER
CLEARING, GRADING, EARTH MOVING OR EXCAVATION IS COMPLETED, TREAT THE DISTURBED
AREA BY WATERING, OR REVEGETATING, OR BY SPREADING SOIL BINDERS UNTIL THE AREA IS
PAVED OR OTHERWISE DEVELOPED SO THAT DUST GENERATION WILL NOT OCCUR.
6.THE CONTRACTOR OR BUILDER SHALL DESIGNATE A PERSON OR PERSONS TO MONITOR THE
DUST CONTROL PROGRAM AND TO ORDER INCREASED WATERING, AS NECESSARY, TO PREVENT
TRANSPORT OF DUST OFFSITE. THEIR DUTIES SHALL INCLUDED HOLIDAY AND WEEKEND PERIODS
WHEN WORK MAY NOT BE IN PROGRESS. THE NAME AND TELEPHONE NUMBER OF SUCH
PERSONS SHALL BE PROVIDED TO THE AIR POLLUTION CONTROL DISTRICT PRIOR TO LAND USE
CLEARANCE FOR MAP RECORDATION AND LAND USE CLEARANCE FOR FINISH GRADING OF
THE STRUCTURE.
C-501
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
0 feet10
1"=5'
5 15
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
RAC
RACJW
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
CONSTRUCTION SPECIFICATIONS:
INSPECTION AND MAINTENANCE:
·SILT FENCES AND FILTER BARRIERS SHALL BE INSPECTED WEEKLY AFTER EACH SIGNIFICANT STORM (1 INCH (25.4 MM) IN 24 HOURS). ANY
REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
·SEDIMENT SHOULD BE REMOVED WHEN IT REACHES 13 HEIGHT OF THE FENCE OR 9 INCHES (0.3 M) MAXIMUM.
·THE REMOVED SEDIMENT SHALL CONFORM WITH THE EXISTING GRADE AND BE VEGETATED OR OTHERWISE STABILIZED.
·THE HEIGHT OF A SILT FENCE SHALL NOT EXCEED 36 INCHES (0.9 M). STORAGE HEIGHT AND PONDING HEIGHT SHALL NEVER EXCEED 18
INCHES (0.5 M).
·THE FENCE LINE SHALL FOLLOW THE CONTOUR AS CLOSELY AS POSSIBLE. IF POSSIBLE, THE FILTER FABRIC SHALL BE CUT FROM A
CONTINUOUS ROLL TO AVOID THE USE OF JOINTS.
·JOINTS, WHEN NECESSARY, SHALL BE SPLICED ONLY AT A SUPPORT POST, WITH A MINIMUM 6 INCH (0.2 M) OVERLAP AND BOTH ENDS
SECURELY FASTENED TO THE POST.
·POSTS SHALL BE SPACED A MAXIMUM OF 10 FEET (3.1 M) APART AND DRIVEN SECURELY INTO THE GROUND (MINIMUM OF 12 INCHES
(0.3M)). WHEN EXTRA-STRENGTH FABRIC IS USED WITHOUT THE WIRE SUPPORT FENCE, POST SPACING SHALL NOT EXCEED 6 FEET (1.8 M).
·TURN THE ENDS OF THE FENCE UPHILL.
·A TRENCH SHALL BE EXCAVATED APPROXIMATELY 4 INCHES (101 MM) WIDE AND 6 INCHES (0.2 M) DEEP ALONG THE LINE OF POSTS AND
UP-SLOPE FROM THE BARRIER.
·WHEN STANDARD-STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UP-SLOPE SIDE OF
THE POSTS USING HEAVY DUTY WIRE STAPLES AT LEAST 1 INCH (25.4 MM) LONG, TIE WIRES OR HOG RINGS. THE WIRE SHALL EXTEND INTO
THE TRENCH A MINIMUM OF 2 INCHES (51MM) ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC SHALL NOT BE STAPLED TO
EXISTING TREES.
·WHEN EXTRA-STRENGTH FILTER FABRIC AND CLOSER POST SPACING ARE USED, THE WIRE MESH SUPPORT FENCE MAY BE ELIMINATED. IN
SUCH A CASE, THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE POSTS.
·THE TRENCH SHALL BE BACKFILLED AND THE SOIL COMPACTED OVER THE TOE OF THE FILTER FABRIC.
·SILT FENCES PLACED AT THE TOE OF A SLOPE SHALL BE SET AT LEAST 6 FEET (1.8 M) FROM THE TOE IN ORDER TO INCREASE PONDING
VOLUME.
·SILT FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN
PERMANENTLY STABILIZED AND ANY SEDIMENT STORED BEHIND THE SILT FENCE HAS BEEN REMOVED.
1 - SET POSTS & EXCAVATE TRENCH
SLOPE SLOPE
2 - INSTALL FILTER FABRIC
STEEL OR
3 - BACKFILL TRENCH
SLOPE
INSTALLED FILTER FABRIC
4 - CROSS SECTION OF
RUNOFF
SILT FENCE INSTALLATION
N.T.S.
SILT FENCE
SCALE: N.T.S.
SILT FENCE CONSTRUCTION DETAIL
STEEL OR
WOOD POST
4" x 4"
TRENCH
2'
MI
N
.
FILTER MESH MATERIAL
ATTACHED TO POSTS AND
EXTENDED INTO TRENCH
STEEL OR
WOOD POST
FILTER MATERIAL
ANCHORED IN
TRENCH
COMPACTED
BACKFILL
10
"
MI
N
.
HALF FULL WITH GRAVEL.
FILL GRAVEL BAGS ONE
WITH HEAVY STRING.
BAG AND TIE SECURELY
GATHER TOP OF GRAVEL
NEXT LAYER.
PRIOR TO STARTING THE
COMPLETING EACH LAYER
GRAVEL BAG INTO PLACE,
ILLUSTRATIONS. STAMP EACH
ACCORDANCE WITH THE
STACK GRAVEL BAGS IN
CARE SHOULD BE TAKEN TO
SCALE: N.T.S.
GRAVEL BAG INSTALLATION
SCALE: N.T.S.
CATCH BASIN INLET SEDIMENT BARRIER
GRAVEL FILLED BAGS
STACKED TIGHTLY -
1 BAG HIGH AT SPILLWAY
OTHERWISE 2 BAGS HIGH
SPILLWAY
CATCH BASIN
12
"
MI
N
.
8 MIL. MIN. VISQUENE
SECURE VISQUENE ONTO
STRAWBALES WITH STAKES OR
ALTERNATE METHOD (TYP.)
1. ALL CONCRETE TRUCKS AND FINISHING TOOLS SHALL BE WASHED AT THE WASH OFF
AREA.
2. ALL CONCRETE WASTE COLLECTED IN WASH OFF AREA SHALL BE RECYCLED OR
APPROPRIATELY DISPOSED OF OFF-SITE.
3. LOCATION AND SIZE OF WASH-OFF AREA MAY BE ADJUSTED TO ACCOMMODATE
SITE CONDITIONS.
STRAWBALE
NOTES:
TYPICAL CONCRETE WASH-OFF AREA SECTION
SCALE: N.T.S.
INSTALLATION TABLE
SLOPE ROLL INTERVAL
4:1 OR FLATTER 20' O.C.
BETWEEN 2:1 AND 4:1 15' O.C.
2:1 AND STEEPER 10' O.C.
NOTES:
PLACE STRAW WATTLE IN TRENCH. WATTLE TO BE TIGHTLY BUTTED END TO
END BUT NOT OVERLAPPING. MINIMUM 6 STAKES PER 25' OF WATTLE.
STRAW WATTLE DETAIL
-NTS-
3"-5"
TRENCH
9" Ø x 25' LONG
STRAW WATTLE
3
4" x 2" x 2' WOOD STAKE IN
CENTER OF WATTLE (2" - 3"
EXPOSED AFTER DRIVING
STAKE)
4' MAX
C-502
ER
O
S
I
O
N
C
O
N
T
R
O
L
N
O
T
E
S
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
RAC
RACJW
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
C-601
DE
T
A
I
L
S
SCALE:E N.T.S.
PERMEABLE PAVER PERFORATED PIPE CROSS-SECTION
RED BRICK PAVERS
WITH JOINTS PER
LANDSCAPE DETAILS
SOIL SUBGRADE, 0% SLOPE
COMPACTED TO 90%
RELATIVE COMPACTION.
ADJACENT REPURPOSED RED
BRICK PER LANDSCAPE DETAILS
FLUSH TRANSITION TO
ADJACENT SURFACE
PERMEABLE PAVER TYPE 1
NOTES:
1.ALL AGGREGATE BASE MATERIAL SHALL BE WASHED, OPEN-GRADED (NO
SAND), CRUSHED (ANGULAR) AGGREGATE.
2.PAVING STONES SHALL BE INSTALLED SMOOTH WITH 1
4" GAPS OR GROOVES
AND PER MANUFACTURER'S SPECIFICATIONS TO ENSURE A LEVEL SURFACE
WHEN EXPOSED TO WEATHER CONDITIONS.
PIPE SIZE PER PLAN
0.5% SLOPE MIN
ROOF DOWNSPOUT
BUILDING
REPURPOSED RED BRICK PAVERS
1.
5
"
G
A
P
CUT HOLE IN 12"X12"
SQUARE GRATE TO MATCH
DIAMETER OF DOWNSPOUT
LOW PROFILE ADAPTER
12" SQUARE TO 4" PIPE
SCALE:A NTS
PIPE OUTLET TO LEVEL SPREADER
ADAPTER TO 4" PVC RISER
4" BRASS GRATE
CONCRETE POUR RING
CONCRETE WALKWAY OR PAVERS
IN
V
E
R
T
A
C
C
O
R
D
I
N
G
T
O
PL
A
N
S
/
T
A
K
E
O
F
F
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
SCALE:B N.T.S.
ATRIUM/DOME GRATE
SLOPE TO DRAIN
ATRIUM OR DOME GRATE
COMPACTED SOIL
DRAIN RISER PIPE
(LENGTH AS REQUIRED, SIZE PER PLAN)
DRAIN TEE OR ELBOW
DRAIN PIPE, SIZE PER PLAN
CRUSHED STONE
SLOPE TO DRAIN
VARIES
LONGITUDINAL 4" PERFORATED
PVC PIPE WRAPPED IN
NON-WOVEN GEOTEXTILE FABRIC
PLACED OVER 1" GRAVEL LAYER
SCALE:C N.T.S.
ROOF DROWNSPOUT OUTLET TO CATCH BASIN
SCALE:D N.T.S.
FLUSH 4" CLEANOUT
REDBRICK BAND, SOLDIER COURSE,
MORTARED TO CONCRETE CURB
2:1
M
A
X
STORMDRAIN AFTER
PASSING THROUGH WALL 6" TEE TO REDIRECT WATER
2" X 12" REDWOOD
HEADER. ENSURE TOP
OF BOARD IS LEVEL
MAINTAIN
UNDISTURBED
NATIVE SLOPE
MAINTAIN
UNDISTURBED
NATIVE SLOPE
2.
0
"
4.
0
"
A
A
LEVEL SPREADER PLAN VIEW
LEVEL SPREADER SECTION A-A
4-6" ROUNDED
RIVER ROCK
2
8'8'
12
.
0
"
////////
//
//
//
////////
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
C O N C R E T E P A D
(N O T A P A R T)
(E) P A R K I N G
L O T
T H E W A R D E N
B L O C K
T O W A R D E N
B R I D G E
W I C K E N D E N
B U I L D I N G
S L O M A
S
A
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
PR
O
P
E
R
T
Y
L
I
N
E
20
'
-
0
"
LOWER STONE WALL
UPPER STONE WALL
20
'
-
0
"
EXISTING
TREE, TYP.
EXISTING
TREE, TYP.
EXISTING
TREE, TYP.
PATIO AREA
PATIO AREA
EDGE OF CREEK
BANK PER CITY
BIOLOGIST
RE
Q
U
I
R
E
D
C
R
E
E
K
S
E
T
B
A
C
K
RE
Q
U
I
R
E
D
C
R
E
E
K
S
E
T
B
A
C
K
CREEK SETBACK AREA: 2,333 SQFT
PROPOSED DECK AREA: 1,096 SQFT rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
75
%
C
O
N
S
T
R
U
C
T
I
O
N
D
O
C
U
M
E
N
T
S
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
1/21/2026
DG
NOT F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
CR
E
E
K
A
N
D
D
E
C
K
A
R
E
A
E
X
H
I
B
I
T
0
SCALE:
feet4812
1/4" = 1'-0"
/ MP
AWB MP
L-001
CREEK AND DECK EXHIBIT LEGEND
03/30/2026
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
TR
E
E
P
R
O
T
E
C
T
I
O
N
M
E
M
O
/ MP
AWB MP
L-002
1 OFFICE: 949.207.3770
WWW.MONARCHU.COM
34237 VIA SANTA ROSA
DANA POINT, CA 92624
TECHNICAL MEMORANDUM
SLOMA Network Expansion Project
DATE: March 24, 2026
SUBJECT: Construction Methods and Protection Requirements for Trees #3, #5, #7, and #14
1. Purpose
This memorandum outlines the specific construction methods and arboricultural requirements for
performing work near four (4) significant trees identified for preservation during the SLOMA Network
Expansion Project. Adherence to these protocols is critical to maintaining tree stability and health
throughout the demolition and construction phases.
2. Target Tree Profiles
All four trees are designated to be Protected In Place using Type III Tree Protection.
• Trees #3, #5, and #7 (California Sycamores): High-value native trees. Trees #3 and #5 show signs
of potential internal decay and may require a level 3 assessment.
• Tree #14 (Holly Oak): Located within a raised planter; requires specific care during the removal
and replacement of surrounding walls.
3. Required Protection Measures
• Type III Protection (Trunk Wrapping): Because these trees are located near the patio or within
planters where installing type I or II protective fencing will not be feasible, the trunks must be
wrapped with a two-inch-thick layer of orange plastic silt fencing from the ground to the lowest
limbs. This must be covered by vertically oriented two-by-four wooden slats to prevent
mechanical damage from equipment.
• Tree Protection Zone (TPZ): Prohibited activities within the TPZ include the storage of materials,
dumping of waste (paint, concrete, etc.), or using trunks for winch support. Soil disturbance or
grade changes are prohibited without arborist approval.
• Root Buffer: a minimum 6 inch deep layer of mulch shall be spread throughout the CRZ of each
the trees and topped with specialized ground protection mats to minimize soil compaction and
reduce the chances of roots being crushed, cracked, or torn by heavy equipment activity.
4. Construction and Excavation Methods
• Exploratory Digging for Helical Piles: Before installing helical piles to support the new deck,
exploratory holes must be carefully hand-dug at pile locations. This allows the team to locate
structurally significant roots and adjust pile locations to avoid damage. Project Arborist must be
on-site during all future exploratory potholing to note the presence of roots, and provide direction
should roots over 2” in diameter be encountered. Any roots that are damaged or severed during
2 OFFICE: 949.207.3770
WWW.MONARCHU.COM
34237 VIA SANTA ROSA
DANA POINT, CA 92624
exploratory digging shall be covered with burlap and kept moist until the potholes can be
backfilled, ideally the same day.
• Below is a statement from the contractor regarding their proposed construction methods:
o “Hand digging using post hole shovels to a minimum depth of 3 feet shall be used at
locations of helical pier and concrete footings for the deck at the creek hillside to
determine the presence of roots. Hand digging shall cease where roots 2 inches or large
are encountered and no helical piers or footings shall be placed in these locations.
o A mini-excavator shall be used to place helical piers within reach from the paver edge.
Helical piers to be placed outside the reach of the mini-excavator shall be installed using
hand operated equipment.
o Specialized root protection mats or a buffer consisting of 6 inches of wood chips should
be used to spread weight and prevent soil compaction when supplemental supporting
equipment is utilized during the helical pier placement.
o Periodic inspections of work effort shall occur to observe compliance. Roots damaged or
severed larger than 2 inches shall be documented and reported to the project arborist
within 6 hours. Work effort shall be conducted in collaboration with the project arborist.”
• Requirements for Work with Permeable Pavers:
o Tree #3: Permeable paver installation involves 35% total Critical Root Zone (CRZ)
encroachment. Excavation for these pavers is limited to a 6-inch depth into native
subgrade and must be performed only with hand tools.
o Tree #14: 19% of its CRZ encroachment is for permeable pavers, which also requires the
exclusive use of hand tools to excavate to a 6-inch depth into native subgrade.
o Removal of existing brick pavers shall be staged in designated areas, and over plywood or
on pallets.
• Utility and Wall Work: Any trenching for utilities or drainage must tunnel under roots two inches
in diameter or larger. Specific care is required when removing the existing walls around the root
zone of Tree #14 to prevent instability. Project arborist shall be on site to confirm the presence of
structurally significant roots.
• Heavy Equipment: Use of backhoes, steel tread tractors, or other heavy vehicles shall be severely
limited within the TPZ, and only used when absolutely necessary.
o Use of heavy equipment within the TPZ is prohibited unless expressly approved by the
project arborist. Where approved, equipment shall operate only over installed root
protection measures (minimum 6 inch mulch layer topped by ground protection mats),
and for the minimum duration necessary. These root buffers shall remain in place
3 OFFICE: 949.207.3770
WWW.MONARCHU.COM
34237 VIA SANTA ROSA
DANA POINT, CA 92624
throughout the life of the project, or until all use of heavy equipment has permanently
ceased.
5. Root Management Protocols
• Two-Inch Rule: All roots encountered that are two inches in diameter or larger must be protected
from damage.
• Severance Procedure: Roots over one inch that must be removed should be cut cleanly with a
hand or chain saw, and the following procedures shall be closely followed in order to prevent root
desiccation:
1. Immediately shade exposed roots by covering the trench sides with burlap.
2. Keep burlap moist by watering twice daily.
3. Before backfilling, sever the root cleanly and place a plastic bag over the cut (secured with
tape or rubber bands).
4. Remove plastic bags immediately prior to backfilling with clean, native material.
6. Monitoring and Maintenance
• Arborist Supervision: the designated project arborist shall be on-site to monitor all work that
takes place within each tree’s CRZ, and direct any necessary pruning of roots over 2 inches in
diameter.
• Irrigation: adequate soil moisture levels shall be maintained throughout the duration of the
project. In order to achieve this, supplemental irrigation shall be applied to each tree’s CRZ at
least twice per month, wetting the soil to a minimum depth of 24 inches. Soaker hoses should be
installed throughout the CRZ prior to the application of mulch and installation of the ground
protection mats, maintaining a buffer of at least two feet away from tree trunks as well as
proposed helical pier sites.
• Damage Reporting: Any accidental injury to branches, trunks, or roots must be reported to the
project arborist within six hours for mitigation recommendations.
All protection measures must be installed prior to the start of construction, and remain in place until final
project inspection. Please do not hesitate to contact me with any questions or concerns you may have
regarding this memorandum.
Evin Lambert
ASCA Registered Consulting Arborist 667
ISA Arborist WE – 9776A
ISA Tree Risk Assessment Qualified
CA Pest Control Adviser 123990
4 OFFICE: 949.207.3770
WWW.MONARCHU.COM
34237 VIA SANTA ROSA
DANA POINT, CA 92624
GLOSSARY OF TERMS
• Advanced Assessment: an assessment performed to provide detailed information about specific tree
parts, defects, or site conditions. Specialized equipment, data collection and analysis, and/or expertise
are usually required.
• Air Excavation Device: device that directs a jet of highly compressed air to excavate soil. Used within
the root zone of trees to avoid or minimize damage to tree roots or near underground structures such
as pipes and wires. May also reduce hazards associated with excavation near pipes or wires.
• Arborist: professional who possesses the technical competence gained through experience and
related training to provide for or supervise the management of trees and other woody plants in
residential, commercial, and public landscapes.
• Basic Assessment: detailed visual inspection of a tree and surrounding site that may include the use
of simple tools. It requires that a tree risk assessor walk completely around the tree trunk looking at
the site, aboveground roots, trunks, and branches.
• Callus: undifferentiated tissue formed by the cambium, usually as the result of wounding (contrast
with woundwood).
• Cambium: thin layer(s) of meristematic cells that give rise (outward) to the phloem and (inward) to
the xylem, increasing stem and root diameter.
• Canopy: collective branches and foliage of a tree or group of trees’ crowns. Aggregate or collective
tree crowns.
• Codominant stems / leaders: forked branches nearly the same size in diameter, arising from a
common junction and lacking a normal branch union.
• Critical Root Zone (CRZ): area of soil around a tree where the minimum amount of roots considered
critical to the structural stability or health of the tree are located. CRZ determination is sometimes
based on the drip line or a multiple of DBH, but because root growth is often asymmetric due to site
conditions, on-site investigation is preferred.
• Crown: upper part of a tree, measured from the lowest branch, including all the branches and foliage.
• Crown Restoration: method of restoring the natural growth habit of a tree that has been topped or
damaged in any other way. Restoration pruning.
• Decay: (1) (noun) an area of wood that is undergoing decomposition. (2) (verb) decomposition of
organic tissues by fungi or bacteria.
• Diameter at Breast Height (DBH): Trunk diameter, measured at 1.4 meters (4.5 feet) above ground.
• Dieback: condition in which the branches in the tree crown die from the tips toward the center.
• Drip Line: imaginary line defined by the branch spread of a single plant or group of plants.
• Epicormic Shoot: shoot arising from a latent or adventitious bud (growth point).
• Girdling Root: root that encircles all or part of the trunk of a tree or other roots and constricts the
vascular tissue and inhibits secondary growth and the movement of water and photosynthates.
• Leader: primary terminal shoot or trunk of a tree. Large, usually upright stem. A stem that dominates
a portion of the crown by suppressing lateral branches.
• Live Crown Ratio (LCR): ratio of the height of the crown containing live foliage to the overall height of
the tree.
• Overextended Branch: a branch that has grown longer than the natural extent of the tree's canopy
and can no longer be securely held before breaking under its own weight. A defect that can lead to
failure of the branch.
5 OFFICE: 949.207.3770
WWW.MONARCHU.COM
34237 VIA SANTA ROSA
DANA POINT, CA 92624
•Resistograph® / microdrill resistance testing:
o Electronically controlled drill resistance measurement device.1
o Use of a small-diameter drill bit on an electric drill, measuring the change of torque resistance
and indicating wood density as the drill bit passes through a trunk or limb. In tree risk assessment,
used to measure the extent of decay.
•Root Barrier: membranes or sheets installed vertically in the soil to limit or direct the growth of tree
roots.
•Root Collar: flared area at the tree trunk base where the roots and trunk come together. See root
crown, root flare, and trunk flare.
•Root collar/root crown excavation: process of removing soil to expose and assess the root collar (root
crown) of a tree.
•Root Pruning: (1) in transplanting, the process of pre-digging a root ball to increase the density of root
development within the final root ball. (2) in tree conservation and preservation, the process of pre-
cutting roots behind the line of a planned excavation to prevent tearing and splintering of remaining
roots. (3) in tree disease management, severing tree roots to prevent disease transmission through
root grafts.
•Root Zone: (1) horizon or layer within the soil profile where roots exist. (2) volume of soil containing
tree roots. (3) horizontal spread of tree roots from the trunk. Typically the root zone of a tree extends
well beyond the drip line.
•Soil Compaction: compression of the soil, often as a result of vehicle or heavy-equipment traffic, that
breaks down soil aggregates and reduces soil volume and total pore space, especially macropore
space.
•Sonic Tomography: use of multiple sensors placed around a trunk or limb to record sound or magnetic
waves traveling through the wood, with measurements resulting in a picture of internal density
characteristics. Typically used to measure the extent of decay.
•Structural Roots: large, woody, tree roots that anchor and support the trunk and crown. Roots
characterized by secondary thickening and relatively large diameter, giving form to the root system
and functioning in anchorage and support.
•Thinning: in pruning, the selective removal of live branches to provide light or air penetration through
the tree or to lighten the weight of the remaining branches.
•Tree Protection Zone (TPZ): defined area within which certain activities are prohibited or restricted
to prevent or minimize potential injury to designated trees, especially during construction or
development.
•Tree Risk Assessment: A systematic process used to identify, analyze, and evaluate the likelihood of
tree failure and associated consequences.
•Trunk Taper: the natural, gradual reduction in diameter of the trunk of a tree from bottom to top.
•Watersprout: upright, epicormic shoot arising from the trunk or branches of a plant above the root
graft or soil line. Incorrectly called a sucker.
•Woundwood: lignified, differentiated tissues produced on woody plants as a response to wounding.
Contrast with callus.
1 ALL DEFINITIONS WERE SOURCED FROM THE ISA-ARBOR.COM ONLINE DICTIONARY, WITH THE EXCEPTION OF “RESISTOGRAPH®”:
HTTP://WWW.RINNTECH.DE/CONTENT/VIEW/8/34/LANG,ENGLISH
6 OFFICE: 949.207.3770
WWW.MONARCHU.COM
34237 VIA SANTA ROSA
DANA POINT, CA 92624
ASSUMPTIONS & LIMITING CONDITIONS
While trees vary in their tolerance to changed conditions, disruption in any form of the environment to
which the trees have grown accustomed may result in adverse reaction. Human activity among and near
trees is inherently contrary to tree welfare and there are inherent risks associated. The following are
limitations to this report:
•All information presented herein covers only the trees examined at the area of inspection, and reflects
the conditions observed of said trees at the time of inspection.
•Observations were performed visually without probing, dissecting, coring, or exaction, unless noted
above, and in no way shall the observer be held responsible for any defects that could have only been
discovered by performing said services in specific area(s) where a defect was located.
•No guarantee or warranty is made, expressed or implied, that defects of the trees inspected may not
arise in the future.
•No assurance can be offered that if the recommendations and precautionary measures are accepted
and followed, that the desired results may be attained.
•No responsibility is assumed for the methods used by any person or company executing the
recommendations provided in this report.
•The information provided herein represents an opinion, and in no way is the reporting of a specified
finding, conclusion, or value based on the retainer.
•This report is proprietary to Monarch Environmental, Inc., and may not be reproduced in whole or
part without written consent. This report has been prepared exclusively for use of the parties to which
it has been submitted.
•Should any part of this report be altered, damaged, corrupted, or lost the entire evaluation shall be
invalid.
•This memorandum shall remain valid for a period of one year from date of delivery, unless stated
otherwise.
2
03/30/2026
////
//
//
//
//
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
C O N C R E T E P A D
(N O T A P A R T)
(E) P A R K I N G
L O T
T H E W A R D E N
B L O C K
T O W A R D E N
B R I D G E
W I C K E N D E N
B U I L D I N G
S L O M A
S L O M A
S
A
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
PR
O
P
E
R
T
Y
L
I
N
E
#3
#2
#1
#5
#4
#7#8
#9
#10
#11
#12
#13
#14
#6 (STUMP)
EXISTING SHRUBS
TO REMAIN
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
EXISTING SHRUB
TO REMAIN
7.
5
'
10
.
5
'
4.
5
'
16
.
5
'
7.
5
'
19
'
TREE PROTECTION FENCING IN THIS
AREA TO BE INSTALLED AFTER
DEMOLITION. REFER TO DEMOLITION
PLAN FOR TREE PROTECTION MEASURES
RELATED TO DEMOLITION.
21
.
5
'
4.
5
'
CONTRACTOR SHALL HAND DIG DEEPENED CURB SECTION
PER DETAIL 4/ L-102 WITHIN CRZ UNDER SUPERVISION AND
DIRECTION OF THE PROJECT ARBORIST, TYP.
PERMEABLE PAVER SECTION WITHIN THE CRZ:
PROPOSED GRADE IN THIS AREA IS 12" ABOVE EXISTING GRADE TO
PROVIDE AN ACCESSIBLE ROUTE. PERMEABLE PAVER DETAIL 2/L-102
CALLS FOR AN 18" EXCAVATION, HOWEVER BECAUSE GRADE IS
BEING RAISED HERE, ONLY 6" OF EXCAVTION IS REQUIRED.
CONTRACTOR SHALL HAND EXCAVATE 6" DEPTH WITHIN CRZ TO
ALLOW FOR EXPOSURE OF EXISTING ROOTS. THIS EXCAVATION
SHALL BE DONE UNDER THE SUPERVISION OF THE PROJECT
ARBORIST WHO WILL EVALUATE CONDITIONS PRIOR TO BASE ROCK
AND PAVER INSTALLATION.
HELICAL PIERS:
HELICAL PIERS SHALL BE PER THE STRUCTURAL DRAWINGS AND
ARE SHOWN ON THIS SHEET FOR REFERENCE ONLY. HELICAL
PIERS ARE DEEP FOUNDATION SUPPORTS THAT ARE SCREWED
INTO THE GROUND WITHOUT THE USE OF CONCRETE. EACH
HELICAL PIER DISRUPTS 0.77SF WITHIN THE CRZ.
CONTRACTOR TO CONDUCT EXPLORATORY POTHOLING WITH
HAND TOOLS UNDER DIRECT SUPERVISION OF THE PROJECT
ARBORIST AT EACH HELICAL PIER LOCATION TO OBSERVE THE
PRESENCE OF LARGE ROOTS. STRUCTURAL ENGINEER SHALL
RELOCATE HELICAL PIERS SHOULD LARGE ROOTS BE
ENCOUNTERED IN ORDER TO PROTECT ROOTS.
CONTRACTOR TO CONDUCT
EXPLORATORY POTHOLING WITH
HAND TOOLS AT WALL TO OBSERVE
THE PRESENCE OF LARGE ROOTS. IF
ROOTS GREATER THAN 2 INCHES ARE
ENCOUNTERED, CONSULT WITH
PROJECT ARBORIST AND LANDSCAPE
ARCHITECT TO EXPLORE ADJUSTMENT
TO THE FOOTING.
#1
#1
SYMBOL DESCRIPTION
X
X
X
EXISTING TREE TO BE REMOVED
NUMBERS PER ARBORIST REPORT
EXISTING TREE TO REMAIN
NUMBERS PER ARBORIST REPORT
EXISTING TREE DRIPLINE
TREE TRUNK PROTECTION PER DETAIL 1
TREE PROTECTION FENCING PER DETAIL 2
CRITICAL ROOT ZONE (CRZ) PER
ARBORIST REPORT
QUANTITY DESCRIPTION
TOTAL EXISTING
REMOVE
REMAIN
13
6
9
PROPOSED
SEE PLANTING PLAN SHEET L-5014
PER TREE INVENTORY TABLE AND ARBORIST REPORT, TREE NUMBER 6 IS
A STUMP THAT SHALL BE CLEARED AND REMOVED. THEREFORE IT DOES
NOT WARRANT AN ADDITIONAL PROPOSED TREE REPLACEMENT.
*
*
THERE IS NOT ADEQUATE ROOM ON THE SITE FOR 5 PROPOSED
REPLACEMENT TREES.
**
**
TREE ID #SPECIES
FICUS BENJAMINA1
DBH DISPOSITION
2
3
FICUS CARICA
PLATANUS RACEMOSA
15 IN REMOVE
7 IN REMOVE
38 IN PROTECT
4
5
LIGUSTRUM JAPONICUM
PLATANUS RACEMOSA
5 IN REMOVE
29 IN PROTECT
6
7
STUMP (PLATANUS RACEMOSA)
PLATANUS RACEMOSA
13 -18 IN REMOVE
21 IN PROTECT
8
9
QUERCUS ILEX
SEQUOIA SEMPERVIRENS
9 IN PROTECT
33 IN PROTECT
10
11
SEQUOIA SEMPERVIRENS
SEQUOIA SEMPERVIRENS
43 IN PROTECT
9 IN PROTECT
12
13
AFROCARPUS FALCATUS
AFROCARPUS FALCATUS
31 IN REMOVE
20 IN REMOVE
14 QUERCUS ILEX 15 IN PROTECT
CRZ
N/A
N/A
19 FT
N/A
7.5 FT
N/A
10.5 FT
4.5 FT
16.5 FT
21.5 FT
4.5 FT
15.5 FT
10 FT
7.5 FT
CRZ ENCROACHMENT %
48%
1.5%
35%
3%
1.2%
N/A
0.1%
0%
5%
7%
0%
42%
28%
34%
OF THE 35% TOTAL ENCROACHMENT OF THE CRZ, 0.6% IS FROM THE HELICAL PIERS AND 34.6% IS THE PERMEABLE PAVER SECTION WHICH TODAY IS
EXISTING BRICK PAVERS. PERMEABLE PAVER ENCROACHMENT IN THIS AREA IS ONLY 6" DEPTH OF EXCAVATION AND WILL BE DONE WITH HAND TOOLS.
*
*
*
OF THE 34% TOTAL ENCROACHMENT OF THE CRZ, 15% IS FROM THE PROPOSED WALL AND 19% IS THE PERMEABLE PAVER SECTION WHICH TODAY IS
EXISTING BRICK PAVERS. PERMEABLE PAVER ENCROACHMENT IN THIS AREA IS ONLY 6" DEPTH OF EXCAVATION AND WILL BE DONE WITH HAND TOOLS.
**
*
HELICAL PIER
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
LA
N
D
S
C
A
P
E
T
R
E
E
PR
O
T
E
C
T
I
O
N
P
L
A
N
TREE DISPOSITION TOTALS
0
SCALE:
1 16 24 feet
/ MP
AWB MP
DIG ALERT
DIAL TOLL FREE
AT LEAST 2 DAYS
BEFORE YOU DIG
TREE PROTECTION FENCING NOTES:
1.TREE PROTECTION FENCING SHALL BE INSTALLED AS INDICATED ON THE TREE PROTECTION PLAN PRIOR TO THE
START OF ANY CLEARING, GRADING, OR OTHER CONSTRUCTION ACTIVITY
2.FENCE SHALL BE MINIMUM 5' TALL CONSTRUCTED OF ORANGE SAFETY FENCING OR APPROVED EQUAL
3.FENCE SHALL BE SUPPORTED BY VERTICAL POSTS SPACED NOT MORE THAN 8' APART
4.AN ALL WEATHER SIGN THAT INCLUDES THE WORDS, “WARNING: TREE PROTECTION ZONE. PLEASE CONTACT THE
PROJECT ARBORIST WITH 48-HOURS NOTICE PRIOR TO RELOCATING OR REMOVING FENCING,” SHALL BE
SECURELY ATTACHED TO THE FENCE IN A VISUALLY PROMINENT LOCATION APPROXIMATELY EVERY 20' AROUND
THE FENCING PERIMETER
TREE PROTECTION FENCING
1/2" = 1'-0"
6" OF BARK MULCH WITHIN TREE
PROTECTION ZONE
5' ORANGE SAFETY FENCING
7' METAL T-POST DRIVEN 2' INTO
EXISTING GRADE
EXISTING TREE
TO REMAIN
TREE PROTECTION ZONE,
SEE PLANS FOR LIMITS
F.G.
5'
-
0
"
RRM-2800-2803.07-57
2
TREE TRUNK PROTECTION
1/4" = 1'-0"
6'
-
0
"
MAINTAIN EXISTING GRADE
WITHIN THE TREE PROTECTION
AREA UNLESS OTHERWISE
INDICATED ON THE PLANS
6 INCHES OF BARK MULCH OUTSIDE
OF FENCING, WITHIN THE TREE
PROTECTION AREA
TREE TRUNK PROTECTION NOTES:
1.NO EQUIPMENT SHALL OPERATE OR BE STORED INSIDE THE TREE PROTECTION AREA.
TREE PROTECTION
AREA, SEE PLANS
FOR LIMITS
STRAW WADDLE WRAPPED TIGHTLY AROUND
TRUNK TO A HEIGHT OF 6'
WOOD 2x4" SPACED 6" O.C. MAX. PLACE
OVER TOP OF STRAW WADDLE
SAFETY FENCING WITH 3.5" x 1.5" OPENINGS
WRAPPED TIGHTLY WITH A MINIMUM OF 4
LAYERS; COLOR: ORANGE. PLACE OVER TOP
OF WOOD TO FULL 6'-0" HEIGHT
1
RRM-2800-2803.07-21
SYMBOL LEGEND
1.THIS PLAN SHALL BE REVIEWED IN CONJUNCTION WITH ARBORIST REPORT PREPARED BY MONARCH
ENVIRONMENTAL DATED DECEMBER 8, 2025
2.PRIOR TO COMMENCEMENT OF CONSTRUCTION, TREE TRUNK PROTECTION AND FENCING SHALL BE
PLACED AROUND EXISTING TREES TO REMAIN AS SHOWN ON THE TREE PROTECTION PLAN AND IN DETAIL 1
AND 2 AT RIGHT.
3.THE TREE PROTECTION AND MONITORING PLAN TO BE IMPLEMENTED OVER THE COURSE OF THE PROJECT
MUST INCLUDE:
·ESTABLISHMENT ZONES OF PROTECTION FOR EACH TREE
·PRE-CONSTRUCTION WORKER TRAINING
·SITE MONITORING DURING CONSTRUCTION
·RECOMMENDED TREATMENTS FOR TREE WOUNDS IF DAMAGED
·POST CONSTRUCTION INSPECTION AND MAINTENANCE REQUIREMENTS
4. TREE PROTECTION ZONES SHALL BE IDENTIFIED AND SECURED WITH PROTECTION FENCING. FENCING SHALL
BE FIVE (5) FOOT TALL ORANGE SAFETY FENCING SECURED WITH STEEL T-POSTS SET AT EIGHT (8) FEET ON
CENTER AND INSTALLED AROUND THE DRIP-LINE PERIMETER OF THE TREES TO BE PROTECTED (AT A
MINIMUM). TREE PROTECTION FENCES MUST BE:
·INSTALLED BEFORE ANY WORK BEGINS
·REMAIN IN PLACE
·CONTINUALLY MAINTAINED
·REMOVED AS THE LAST ITEM OF WORK
5.IN TREE PROTECTION ZONES OR UNDER TREE DRIPLINES, DO NOT:
•PARK VEHICLES OR CONSTRUCTION EQUIPMENT OR STOCKPILE MATERIALS
•DUMP WATER, WASTE OR CONSTRUCTION MATERIALS WITHIN 20 FEET OF THE DRIP
LINE OF TREES TO BE PROTECTED
•APPLY HERBICIDE, INCLUDING PRE AND POST EMERGENT, WITHIN 20 FEET OF THE
DRIP-LINE OF TREES TO BE PROTECTED.
6.EXCAVATION, GRADING, TRENCHING AND BORING
•DIGGING ACTIVITIES IN TREE PROTECTION ZONES MUST BE DONE BY HAND
•ROOTS ENCOUNTERED LARGER THAN ONE (1) INCH SHALL BE CUT CLEANLY
•ROOTS ENCOUNTERED MUST BE PROTECTED FROM SCARRING AND DRYING
•ATTEMPTS MUST BE MADE TO TUNNEL UNDER ROOTS.
•ROOTS MUST BE SHADED FROM DIRECT SUNLIGHT WHEN EXPOSED FROM
DIGGING.
·DEMOLITION AND GRADING WITHIN THE TREE PROTECTION ZONES OF EXISTING TREES TO REMAIN
SHALL BE MINIMIZED AND SHALL ONLY BE DONE UNDER THE DIRECT SUPERVISION OF THE
PROJECT ARBORIST. THIS TYPE OF WORK SHALL BE PERFORMED USING HAND TOOLS OR, WHEN
NECESSARY, WITH LIGHT (ONE TON OR LESS) RUBBER-TRACKED EQUIPMENT.
7.PRUNING
•TREE PRUNING MUST BE DONE BY A CERTIFIED ARBORIST IN ACCORDANCE WITH
INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA) STANDARDS. IN NO CASE SHALL
MORE THAN ONE-THIRD OF THE TREE CANOPY BE REMOVED.
·SHOULD PRUNING OF EXISTING TREES BE REQUIRED IT MUST BE KEPT TO A MINIMUM AND SHALL
COMPLY WITH ANSI A300 STANDARDS.
·ROOT OR CROWN PRUNING SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF THE
PROJECT ARBORIST. NOTIFY THE PROJECT ARBORIST AT LEAST 48 HOURS IN ADVANCE OF ANY
ROOT OR CROWN PRUNING ACTIVITY TO COORDINATE A SITE VISIT.
·ANY TREE ROOTS ENCOUNTERED WITHIN THE TREE PROTECTION ZONE OVER 1" IN DIAMETER SHALL
BE CLEANLY SEVERED WITH A HAND, CHAIN, OR RECIPROCATING SAW PERPENDICULAR TO THE
DIRECTION OF GROWTH TO MINIMIZE THE SURFACE AREA OF THE WOUND. SEVERED ROOTS
SHALL BE COVERED WITH SOIL IN THE FINAL GRADING CONDITION AND NO SEVERED ROOTS
SHALL BE EXPOSED TO AIR OR SUNLIGHT FOR MORE THAN 48 HOURS.
·IF ROOT PRUNING OCCURS, SUPPLEMENTAL WATER MAY BE REQUIRED WITHIN THE TREE
PROTECTION ZONE. LOCATIONS AND FREQUENCY SHALL BE DIRECTED BY THE PROJECT
ARBORIST.
TREE PROTECTION NOTES
L-100
TREE PROTECTION DETAILS
1/8" = 1'-0"
2 4 8
TREE INVENTORY TABLE
03/30/2026
SD
SD
SD
S
D
S
D
S
D
S
D
SD
SD
SD
SD
SD
SD
S
D
SD
S
D
SD
S
D
SD
S
D
S
D
S
D
S
D
SD
S
D
SD
S
D
S
D
S
D
S
D
SD
S
D
SD
SD
SD
S
D
S
D
SD
S
D
SD
SD
SD
S
D
S
D
SD
S
D
SD
SD
SD
S
D
SD
SD
S
D
S
D
S
D
S
D
S
D
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
S
D
////////
//
//
//
//
//
//
//
//////
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
C O N C R E T E P A D
(N O T A P A R T)
(E) P A R K I N G
L O T
T H E W A R D E N
B L O C K
T O W A R D E N
B R I D G E
W I C K E N D E N
B U I L D I N G
S L O M A
S L O M A
S
A
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
GB
GB
PR
O
P
E
R
T
Y
L
I
N
E
#3
#2
#1
#5
#4
#7#8
#9
#10
#11
#12
#13
#14
#6 (STUMP)
38°
4
L-102
4
L-102
7
L-102
8
L-102
PL-01
PL-01
PL-01
PL-01
WC-02
WC-02
PL-01
PL-01
WC-03
LI-02
LI-02
PL-01
LI-01
FR-01
FR-02
EXISTING STONE WALL
TO REMAIN IN PLACE
VERTICALLY SAWCUT
STONE WALL AT THIS
LOCATION, APPLY
SALVAGED ROCK TO
CUT FACE TO FORM
COHESIVE WALL
EXISTING STONE WALL
BELOW DECK, TYP.
EXISTING STONE WALL
BELOW DECK, TYP.
APPLY LIQUID
WATERPROOFING
AT BUILDING WALL
WHERE ADJACENT
TO PLANTER, TYP.
WC-04
WC-04
TRUNK PERIMETER VARIES,
VERIFY IN FIELD. CONSTRUCT
DECK COLLAR AROUND
TRUNK WITH 3" MAXIMUM GAP.
EXISTING STONE WALL
TO REMAIN IN PLACE
EXISTING STONE WALL
TO REMAIN IN PLACE
EXISTING TREE TO
REMAIN, TYP.
WC-05
WC-05
BEGIN
FR-01 END
TRUNK PERIMETER VARIES,
VERIFY IN FIELD. CONSTRUCT
DECK COLLAR AROUND
TRUNK WITH 3" MAXIMUM GAP.
END
BEGIN
WC-01
BEGIN
END
WC-04
WC-02
FR-03
FR-03
LI-01
LI-01
LI-01
LI-02
LI-02
WC-05
WC-05
WC-01
LI-01
LI-01
ATTACH STRING LIGHTS TO
BUILDING FACE, TYP.
ATTACH STRING
LIGHTS TO BUILDING
FACE, TYP.
APPLY LIQUID
WATERPROOFING
AT BUILDING WALL
WHERE ADJACENT
TO PLANTER, TYP.
WC-06
WC-06
WC-06
WC-06
APPROXIMATE LOCATION
OF EXISTING PG&E
ELECTRICAL PANELS
WC-02
FR-03
UT-01
UT-02
UT-02
UT-03
UT-03
UT-02
LI-03
(BELOW SEAT)
(BELOW SEAT)
(BELOW SEAT)
CONCRETE STEP
REFER TO CIVIL PLANS
EXISTING STONE WALL
TO REMAIN IN PLACE
VERTICALLY SAWCUT STONE
WALL AT THIS LOCATION, APPLY
SALVAGED ROCK TO CUT FACE
TO FORM COHESIVE WALL
ALIGN WC-02 WITH EDGES
OF BUILDING STOREFRONT
FRAME AS SHOWN
LI-03
EXISTING SHRUBS
TO REMAIN, TYP.
SI-01
EXISTING SHRUB
TO REMAIN, TYP.
EXISTING TREE TO
BE REMOVED, TYP.
SS-02
SS-02
WC-02
WC-02
CONTRACTOR TO CONDUCT
EXPLORATORY POTHOLING WITH
HAND TOOLS AT WALL TO OBSERVE
THE PRESENCE OF LARGE ROOTS. IF
ROOTS GREATER THAN 2 INCHES ARE
ENCOUNTERED, CONSULT WITH
PROJECT ARBORIST AND
LANDSCAPE ARCHITECT TO EXPLORE
ADJUSTMENT TO THE FOOTING.
5/L-103
SYMBOL DESCRIPTION DETAIL
BRICK PAVING - PERMEABLE
RE-USE OF EXISTING BRICKS WITH 1/4" JOINTS FILLED
WITH NO. 8 STONE
2/L-102
BRICK PAVING
RE-USE OF EXISTING BRICKS, SAND SET
1/L-102
CONCRETE PAVING
FINISH: LIGHTLY BROOMED
COLOR: NATURAL GRAY
6/L-102
DECKING
MANUFACTURER: TREX
PRODUCT: TRANSCEND COMPOSITE DECKING
COLOR: SPICED RUM
PAVING AND SURFACING (PA)
CODE DESCRIPTION DETAIL
PLANTER AREA WITH GRAVEL MULCH
SUPPLIER: CENTRAL COAST LANDSCAPE PRODUCTS
SIZE: 3/8" CRUSHED GRAVEL
COLOR: CALIFORNIA GOLD
9/L-102PL-01
PLANTING AND IRRIGATION (PL)
CODE DESCRIPTION DETAIL
STRING LIGHT POST 2/L-103
STRING LIGHTS
STRING LIGHT POST IN FOOTING 7/L-103
LI-01
LI-02
LI-03
SITE LIGHTING AND ELECTRICAL (LI)
//
SEE S
SHEETS
CODE DESCRIPTION DETAIL
ATRIUM GRATE
SEE CIVIL SHEETS
ROOF DOWNSPOUT OUTLET TO CATCH BASIN
SEE CIVIL SHEETS
RIPRAP APRON AT PIPE OUTLET
SEE CIVIL SHEETS
UT-01
UT-02
UT-03
UNDERGROUND UTILITIES (UT)
B/C-601
C/C-601
A/C-601
SEE S
SHEETS
SEE SHEET
E-112
CODE DESCRIPTION DETAIL
DECK
SEE STRUCTURAL SHEETS FOR DETAILS
HELICAL PIER
SEE STRUCTURAL SHEETS FOR DETAILS
SS-01
SS-02
SITE STRUCTURES (SS)
SEE S
SHEETS
CODE DESCRIPTION DETAIL
PERFORATED STEEL SCREEN ON WALL
DECORATIVE PANELS - WEATHERING STEEL
MANUFACTURER: BOK MODERN
5/L-103
PERFORATED STEEL EQUIPMENT SCREEN
HINGED TO ALLOW FOR ACCESS - WEATHERING STEEL
MANUFACTURER: BOK MODERN
3/L-103
DECK GUARDRAIL 1/L-103
FR-01
FR-02
FR-03
FENCES, RAILINGS, AND GATES (FR)
CODE DESCRIPTION DETAIL
CONCRETE PLANTER WALL WITH WOOD SEAT
CONCRETE FINISH: BOARD-FORMED
COLOR: DAVIS COLORS 860 - COBBLESTONE
WOOD SEAT MANUFACTURER: TOURNESOL, 'WALLY'
TYPE A
8/L-102
CONCRETE FLUSH CURB - 8" WIDE 5/L-102
WEATHERING STEEL PLANTER WITH WOOD SEAT
MANUFACTURER: TOURNESOL
PRODUCT: KITSAP MODULAR PLANTER
BENCH: 'WALLY' TYPE A
7/L-102
WEATHERING STEEL PLANTER EDGING
FABRICATED
10/L-102
DEEPENED CURB WITH MORTARED BRICK BAND 3/L-102
DEEPENED CURB ADJACENT TO DECK 4/L-102
WC-01
WC-02
WC-03
WC-04
WC-05
WC-06
WALLS AND CURBS (WC)
CODE DESCRIPTION DETAIL
ENTRY SIGNAGE ON STEEL SCREEN 6/L-103SI-01
SIGNAGE AND STRIPING (SI)
32/S-243
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
LA
N
D
S
C
A
P
E
CO
N
S
T
R
U
C
T
I
O
N
P
L
A
N
CONSTRUCTION SCHEDULE
0
SCALE:
feet4812
1/4" = 1'-0"
/ MP
AWB MP
DIG ALERT
DIAL TOLL FREE
AT LEAST 2 DAYS
BEFORE YOU DIG
L-101
03/30/2026
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
LA
N
D
S
C
A
P
E
CO
N
S
T
R
U
C
T
I
O
N
D
E
T
A
I
L
S
/ MP
AWB MP
CONCRETE PAVING
1 1/2" = 1'-0"
4"
4"
2"
A
T
P
L
A
N
T
E
R
A
R
E
A
S
1/4" RAD. TYP.
CLASS 2 AGGREGATE
BASE @ 95% COMPACTION6"
8"
CONCRETE PAVING.
SEE SCHEDULE FOR FINISH
AND COLOR.
TURN-DOWN EDGE ADJACENT
TO BRICK PAVING ONLY
SUBGRADE @ 90% COMPACTION
OF MAXIMUM DRY DENSITY
#4 REBAR @ 18" O.C.,
BOTH WAYS.
3"#4 REBAR, CONT. AT
THICKENED EDGE
FS
RRM-2400-2803.07-01
6
FS
CONCRETE FLUSH CURB - 8" WIDE
1 1/2" = 1'-0"
COMPACTED SUBGRADE @ 90%
RELATIVE COMPACTION
(1) #4 REBAR, CONT. HORIZ.,
CENTERED IN CURB.
CONCRETE WITH MEDIUM BROOM FINISH,
PERPENDICULAR TO DIRECTION OF CURB
NOTES:
1.PROVIDE CONTRACTION JOINT EVERY 10' MAX.
2.PROVIDE EXPANSION JOINT EVERY 20' MAX.
3.SPACE JOINTS EVENLY BETWEEN BEGINNING AND END POINTS.
4.TOP OF CURB TO BE FLUSH WITH ADJACENT PAVING WHERE APPLICABLE.
2" IN PLANTING AREA
10
"
1/4" RADIUS TYP.
FLUSH
1
L-102
BRICK PAVING
8"
RRM-2400-2803.07-77
5
BRICK PAVING
1 1/2" = 1'-0"
1"
6"
CLASS 2 AGGREGATE BASE
@ 95% RELATIVE COMPACTION
NATIVE SUBGRADE @ 90%
RELATIVE COMPACTION
WASHED CONCRETE
SAND SETTING BED
PLAN VIEW
HERRINGBONE PATTERN
NOTES:
1.TREAT EXISTING SOIL AND BACKFILL
WITH GROWTH INHIBITOR.
2.CLEAN BRICK AND SEAL BRICK
SURFACE WITH PROSOCO OR
APPROVED EQUAL SEALANT.
BRICK PAVING, SALVAGED
EXISTING BRICKS
PROVIDE POLYMETRIC SAND
IN 1/8" SPACED JOINTS, TYP.
SOIL SEPARATOR FABRIC.
MIRAFI MODEL "N" OR
APPROVED EQUAL
1
RRM-2400-2803.07-19
DEEPENED CURB WITH MORTARED BRICK BAND
1 1/2" = 1'-0"
COMPACTED SUBGRADE @ 90%
RELATIVE COMPACTION
(3) #4 REBAR, 12" O.C. CONT.
HORIZ., CENTERED IN CURB.
SOLDIER COURSE BRICK BAND
MORTARED IN PLACE
1" MORTAR BED
FLUSH
TYP.
8"NOTES:
1.PROVIDE CONTRACTION JOINT EVERY 10' MAX.
2.PROVIDE EXPANSION JOINT EVERY 20' MAX.
3.SPACE JOINTS EVENLY BETWEEN BEGINNING AND END POINTS.
4.TOP OF CURB TO BE FLUSH WITH ADJACENT PAVING WHERE APPLICABLE.
1
L-102
BRICK PAVING2
L-102
BRICK PAVING - PERMEABLE
3"
C
L
R
.
1'
-
6
"
PLAN VIEW
3
RRM-2800-2803.07-02
BRICK PAVING - PERMEABLE
1 1/2" = 1'-0"
PLAN VIEW
RUNNING BOND PATTERN
NOTES:
1.TREAT EXISTING SOIL AND BACKFILL
WITH GROWTH INHIBITOR.
2.CLEAN BRICK AND SEAL BRICK
SURFACE WITH PROSOCO OR
APPROVED EQUAL SEALANT.
3.INSTALL PATTERN PERPENDICULAR TO
WALKWAY PER PLAN
NO. 57 STONE
OPEN-GRADED BASE
NO. 2 STONE SUBBASE
GEOTEXTILE ON
BOTTOM AND SIDES OF
OPEN-GRADED BASE.
MIRAFI MODEL "N" OR
APPROVED EQUAL
UNDISTURBED NATIVE SOIL
PERFORATED DRAIN.
SEE SHEET C-301 FOR
LOCATIONS
NO. 8 AGGREGATE
BEDDING COURSE
BRICK PAVING, SALVAGED
EXISTING BRICKS
PROVIDE NO. 8 STONE IN 1/4"
SPACED JOINTS, TYP.
2"
2"
4"
12
"
1'
-
8
"
RRM-2800-2803.07-03
2
CANTILEVERED MOUNTED TOURNESOL,
WALLY BENCH LY-A30-96, WOODEN
BACKLESS BENCH, TYP.
WEATHERING STEEL PLANTER WITH WOOD SEAT
3/4" = 1'-0"
STAINLESS STEEL MOUNTING
HARDWARE PER MANUFACTURER, TYP.
INTERNAL BENCH SUPPORT BRACKET AT
EACH BENCH MOUNTING LOCATION,
PER MANUFACTURER, TYP.
3/8" DIA SS EXPANSION OR EXPOXY ANCHORS
AT EACH ANCHOR LOCATION, TYP.
CONTINUOUS CURB ALONG LENGTH OF
PLANTER WALL, ADJACENT TO BRICK PAVING
#4 REBAR, 12" O.C.,
BOTH WAYS. TYP.
COMPACTED SUBGRADE @
90% RELATIVE COMPACTION
BUILDING EDGE
LIQUID WATERPROOFING
AT BACK OF BUILDING, TYP.
DEEPENED CONTINUOUS
CURB ALONG LENGTH OF
PLANTER WALL, ADJACENT TO
PERMEABLE BRICK PAVING
SE
T
F
S
5
"
M
A
X
.
A
B
O
V
E
CO
N
C
R
E
T
E
F
O
O
T
I
N
G
1'
-
6
"
PLANTER WIDTH PER PLAN
SE
T
F
S
5
"
M
A
X
.
A
B
O
V
E
CO
N
C
R
E
T
E
F
O
O
T
I
N
G
#4 REBAR, 12" O.C.,
BOTH WAYS. TYP.
COMPACTED SUBGRADE @
90% RELATIVE COMPACTION
2" LAYER OF GRAVEL MULCH
CONDITION AT STANDARD BRICK PAVING CONDITION AT PERMEABLE BRICK PAVING
2
L-102
BRICK PAVING -
PERMEABLE
FS FS
1
L-102
BRICK PAVING
3" CLR.
3" CLR.
1'-6" TYP.
PL
A
N
T
E
R
H
E
I
G
H
T
:
2
'
-
0
"
6"
(BEHIND BRACE) DRAIN ROCK AND PERFORATED
DRAIN WRAPPED IN LANDSCAPE FABRIC. SEE
SHEET C-301 FOR LOCATIONS, TYP.
1'-0"
1'
-
6
"
1'-0"
1'
-
6
"
T
Y
P
.
7
RRM-2800-2803.07-06
CONCRETE PLANTER WALL WITH WOOD SEAT
3/4" = 1'-0"
2'
-
0
"
TOURNESOL WALLY COLLECTION "A"
WOOD AND STEEL FLAT BENCH, LY-A30-72
3/4" DRILLED HOLE WITH 3/8" X 6" THREADED
ROD WITH NUT EMBEDDED WITH EPOXY
1/2" RADIUS ON ALL SIDES, TYP.
CONCRETE WALL WITH DAVIS COLORS 860
COBBLESTONE, BOARD-FORM FINISH, USE
2X6 ROUGH-SAWN CEDAR FORMS
#5 @ 12" O.C., BOTH WAYS.
TYP. HOOK AT FOOTING
COMPACTED SUBGRADE @ 90%
RELATIVE COMPACTION
1'
-
0
"
3" CLR.
1
L-102
BRICK PAVING
1'-6"
2"
DRAIN ROCK AND PERFORATED
DRAIN WRAPPED IN LANDSCAPE
FABRIC. SEE SHEET C-301 FOR
LOCATIONS
6"
6"
1'
-
6
"
2'-8"
8'-0"
WATERPROOFING AT BACK
OF WALL, TYP.
WALL LIGHT WHERE OCCURS,
SEE ELECTRICAL PLANS
10
"
8
RRM-2800-2803.07-49
DEEPENED CURB ADJACENT TO DECK
1 1/2" = 1'-0"
FLUSH
NOTES:
1.PROVIDE CONTRACTION
JOINT EVERY 10' MAX.
2.PROVIDE EXPANSION
JOINT EVERY 20' MAX.
3.SPACE JOINTS EVENLY
BETWEEN BEGINNING
AND END POINTS.
4.TOP OF CURB TO BE
FLUSH WITH ADJACENT
PAVING.
FSFS
2
L-102
BRICK PAVING -
PERMEABLE
FLUSH
COMPACTED SUBGRADE @ 90%
RELATIVE COMPACTION
8" CURB WIDTH
1/8" - 1/4" MAX. GAP BETWEEN
DECK AND CURB
3'
-
0
"
ISOLATION JOINT
ALONG EXISTING WALL
SLOPED CREEK BANK 6"
M
A
X
G
A
P
B
E
T
W
E
E
N
WA
L
L
A
N
D
D
E
C
K
SEE STRUCTURAL SHEET
S-242 FOR DECK FRAMING
#4, 12" O.C., EACH WAY,
CENTERED IN CURB
1'-6"
4"
B
E
L
O
W
A
D
J
A
C
E
N
T
DE
S
C
E
N
D
I
N
G
S
L
O
P
E
1/4" RADIUS, TYP.
10"
10
"
EXISTING STONE WALL
3" MIN.
CLR.
RRM-2800-2803.07-50
4
4"
6"
1'
-
0
"
WEATHERING STEEL PLANTER EDGING
2" = 1'-0"
1/8" THICK PLATE STEEL EDGE,
SET 4" ABOVE ADJACENT F.S.
ROLL TOP EDGE OF STEEL
TOWARDS PLANTER, 1/4" RADIUS
1"
2"
5
L-102
CONCRETE FLUSH
CURB - 8" WIDE
1
L-102
BRICK PAVING
9
L-102
FS
EMBED STEEL EDGING 6"
MIN. ADJACENT TO CURB
FASTEN TO CONCRETE WITH 1/2" X 3"
ANCHOR BOLTS, DRILL THROUGH
PLATE INTO CONCRETE @ 18" O.C.
5"
10
RRM-2800-2803.07-59
GRAVEL MULCH
1" = 1'-0"
2" THICK LAYER OF 3/8" CRUSHED
GRAVEL, CALIFORNIA GOLD
SOIL SEPARATOR FABRIC.
MIRAFI MODEL "N" OR EQUAL
TURN DOWN SOIL SEPERATOR FABRIC AT
ADJACENT FLATWORK 4" MIN.
PLANTING BACKFILL MIX
5
L-102
CONCRETE FLUSH
CURB - 8" WIDE
1
L-102
BRICK PAVING
FSFLUSH
9
RRM-2800-2803.07-36
L-102
CONCRETE PLANTER WALL W/ FENCE AT PROPERTY LINE
3/4" = 1'-0"
1'-0"
EQEQ
8"
3"
CLR
2'
-
0
"
EXISTING
ASPHALT
FENCE PER MANUFACTURER
6'
-
0
"
MA
X
1'-0"9"9"
3"
CL
R
WATERPROOFING
DRAIN
2"
CL
R
1'
-
0
"
10
"
6"
CONCRETE KEY
COMPACTED SUBGRADE
#4 @ 12" OC TOP &
BOTTOM, EA WAY
#4 @ 12 OC EA WAY
11
RRM-2800-2803.07-103
03/30/2026
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
LA
N
D
S
C
A
P
E
CO
N
S
T
R
U
C
T
I
O
N
D
E
T
A
I
L
S
/ MP
AWB MP
STRING LIGHT POST
3/4" = 1'-0"
HAND HOLE FOR RECEPTACLE WHERE
OCCURS, SEE ELECTRICAL SHEETS.
4
L-103
STRING LIGHT ATTACHMENT
- POST SECTION
1'
-
0
"
4 X 4 X 5/8 CORTEN PL
CONTINUOUS POST
TYP 3
SIDES
10
'
-
6
"
CONDUIT COUPLER
FRONT ELEVATION
1
L-103
DECK GUARDRAIL
WELD TOP FRONT 4 X4 X1/4 SQUARE
PL TO MOUNT STRING LIGHTS
SIDE ELEVATION
GUARDRAIL CONNECTION32
S-243
1/4" CORTEN PL SUPPORTS
10
'
-
6
"
3'
-
6
"
3'
-
6
"
3D VIEW - NOT TO SCALE
NOTE:
1.ALL WELDS SHALL BE CONTINUOUS AND GROUND SMOOTH.
AT STRING LIGHT POST
1
4
1
4
TYP 2 SIDES
EA PL1
4
RRM-2800-2803.07-18
2
SS 18" CABLE
SS 3 16" CABLE CLAMPS SS TURNBUCKLE
SS ELECTRICAL TIE
SS 18" CABLE
STRING LIGHT
WRAP STRING LIGHT CABLE
AROUND SS CABLE
CABLE
THIMBLE
STRING LIGHT ATTACHMENT - POST SECTION
1/4" = 1'-0"
SS 1/2"X2" EYE BOLT
SS CABLE THIMBLE
2"
2
L-103
STRING LIGHT POST
NUT
CLOSE TOP OF POST WITH
WELDED 4"X4" PL
RRM-2800-2803.07-53
4 PERFORATED STEEL EQUIPMENT SCREEN
1/2" = 1'-0"
4'-0" CLEAR OPENING
VERIFY WIDTH IN FIELD
6'
-
0
"
3'
-
0
"
1'-6"
BOK MODERN MECHANICAL SCREEN, B47 PATTERN,
CORTEN, WELD TO HSS PER MANUFACTURER
(3) WELD ON CORTEN HINGES, TYP. SEE
ENLARGEMENT BELOW, PANEL TO SWING
OUTWARD FULL 90 DEGREES
HSS 2 X 4 X 1/8 CORTEN POST
2"
1'
-
0
"
CL
R
.
PLAN VIEW
FRONT ELEVATION
1
8"
FG
CORTEN 4" ROUND BARREL
BODY HINGE, 3/4" DIA. STEEL
PIN, WELD IN BETWEEN SQUARE
STEEL TUBE POST AND SCREEN
PANEL
COMPACTED SUBGRADE @ 90%
RELATIVE COMPACTION
CONCRETE FOOTING
AT EACH POST
9
L-102
GRAVEL MULCH
CONCRETE
FOOTING BELOW
SEE PLAN VIEW HINGE ATTACHMENT BELOW
3'
-
0
"
8"
6"
7"
WELD CAP PLATE AT TOP OF POST
8'
-
8
"
WELD ON
LATCH
6"
1" PANEL FRAME
1" HINGE & LATCH
CLEARANCE
3'-10" PANEL WIDTH
1"
4'
-
1
0
"
P
A
N
E
L
H
E
I
G
H
T
NOTES:
1.ALL WELDS SHALL BE CONTINUOUS AND
GROUND SMOOTH.
2.LOCATE EXISTING PG&E PANELS AND
ENSURE WIDTH OF SCREEN IS SUFFICIENT TO
COVER UTILITIES AND PROVIDE ACCESS.
3
RRM-2800-2803.07-08
L-103
DECK GUARDRAIL
3/4" = 1'-0"
3'
-
6
"
3 1/2" SPACING
IN BETWEEN POSTS
4"
SQ.1/4" CORTEN PL
2" FROM CORNERS
PT JOIST PER
STRUCTURAL
TREX DECKING PER PLAN
PT RIM BOARD PER
STRUCTURAL
7 1/2" O.C.
POST SPACING
GUARDRAIL CONNECTION12
S-243
2
L-103
STRING LIGHT POST
9 X 4 X 1/4 PL WELDED TO POST
FOR MOUNTING PER STRUCTURAL
SECTION VIEW A
VIEW FROM DECK
VIEW FROM CREEK
A
1
RRM-2800-2803.07-90
STRING LIGHT POST IN FOOTING
3/4" = 1'-0"
ALL EXPOSED CONDUIT ABOVE DECK
FRAMING SHALL BE 1/2" CORTEN
TUBING WELDED TO INSIDE OF POST
1'-6"
3'
-
0
"
FG
2"CONCRETE FOOTING
COMPACTED SUBGRADE @ 90%
RELATIVE COMPACTION
2
L-103
STRING LIGHT POST
STANDARD BELOW
GRADE CONDUIT
PER ELECTRICAL
NOTE:
1.ALL WELDS SHALL BE CONTINUOUS AND GROUND SMOOTH.
1'-6"
6"
6'
-
0
"
3" CLR. MIN.
(3) #3 TIES AT TOP OF FOOTING
PER PLAN VIEW ABOVE
#3 TIES @ 12" OC PER
PLAN VIEW ABOVE
(4) #4 VERT REINF
PROVIDE 1/4" CORTEN PL AT BASE
AND 18" OC WHILE IN FOOTING
STAGGER HOOK
@ ALT TIES
3"
D= 1 1/2" DIA. BEND
8 1/2" OVERL
A
P
3" CLR.
MIN. TYP.
135 DEG. SEISMIC HOOK
@ EA END OF TIE
PLAN VIEW
SECTION
7
RRM-2800-2803.07-98
PERFORATED STEEL SCREEN ON WALL
3/8" = 1'-0"
SURFACE MOUNT PER MANUFACTURER
TO TOP OF CONCRETE WALL, TYP.
FRONT ELEVATION - PATIO SIDE
PLAN VIEW
PATIO SIDE
EXISTING PARKING LOT SIDE
1'-0"
CONCRETE FLUSH CURB - 8"
WIDE
5
L-102 - BEGIN
FS
4"
-
C
E
N
T
E
R
P
A
N
E
L
S
O
N
TO
P
O
F
C
O
N
C
R
E
T
E
W
A
L
L
EQ
6'
-
0
"
M
A
X
2"
C
L
R
.
TY
P
.
CONCRETE PLANTER WALL
WITH WOOD SEAT
8
L-102
5'-2"
VERIFY IN FIELD
PA
N
E
L
H
E
I
G
H
T
,
V
E
R
I
F
Y
I
N
FI
E
L
D
W
I
T
H
S
E
A
T
W
A
L
L
SE
A
T
W
A
L
L
H
E
I
G
H
T
P
E
R
GR
A
D
I
N
G
P
L
A
N
OV
E
R
A
L
L
M
A
X
H
E
I
G
H
T
:
6
'
-
0
"
SLOMA BUILDING
EDGE, TYP.
BOK MODERN "NO-POST" STYLE PERFORATED CORTEN STEEL
SCREEN PANELS. PANELS ARE MOUNTED TO FACE OF MOUNTING
FINS PER MANUFACTURER TO FORM A SEAMLESS PANEL DESIGN.
BOK MODERN SHOULD PROVIDE FINAL SHOP DRAWINGS OF
FENCE DESIGN SHOWING CUSTOM PATTERN, DIMENSIONS TO FIT
WALL SHAPE AND MOUNTING BRACKET LOCATIONS.
SURFACE MOUNT PER MANUFACTURER TO TOP OF
ADJACENT CONCRETE SURFACE, TYP. CONTRACTOR
TO SUBMIT PROPOSED ANCHORAGE TO STRUCTURAL
ENGINEER OF RECORD PRIOR TO INSTALLATION
ENTRY SIGNAGE ON STEEL
SCREEN
6
L-103
EQ4" MAX, 2" MIN
VERIFY IN FIELD
5'-2"
VERIFY IN FIELD
34'-0"
3'-8"
EQ
3'-8"
EQ
3'-8"
EQ
3'-8"
EQ
3'-8"
EQ
3'-8"
EQ
3'-8"
EQ
3'-8"
EQ
3'-8"
EQ
3
'
-
0
"
1
'
-
0
"
4" MAX, 2" MIN
VERIFY IN FIELD
2" CLR.
TYP.
PATTERN TO BE CONTINUOUS PER MANUFACTURER,
ENSURE MOUNTING FINS ARE NOT VISIBLE
THROUGH PANEL PERFORATIONS, SHOWN AS
REFERENCE ONLY, TYP.
CONCRETE PLANTER WALL
WITH WOOD SEAT
8
L-102
RRM-2800-2803.07-100
5
LOCATION FOR SLOMA
ENTRY SIGNAGE
2'-10"
2'-6"
2'
-
0
"
2" CLR. FROM
BRACKETS, TYP.
8"
2
'
-
1
0
"
FS
PLAN VIEW
PA
N
E
L
H
E
I
G
H
T
,
V
E
R
I
F
Y
I
N
FI
E
L
D
W
I
T
H
S
E
A
T
W
A
L
L
OV
E
R
A
L
L
M
A
X
H
E
I
G
H
T
:
6
'
-
0
"
ENTRY SIGNAGE ON STEEL SCREEN
1/2" = 1'-0"
ELEVATION A
PERFORATED STEEL SCREEN
ON WALL
5
L-103
A
CONCRETE PLANTER WALL
WITH WOOD SEAT
8
L-102
FASTEN SIGN TO SCREEN
PER MANUFACTURER'S
RECOMMENDATIONS
6
RRM-2800-2803.07-102
03/30/2026
OUTDOOR PATIO SPACE: 30'-6"RAISED CONCRETE
PLANTER WITH SEATWALL
PERMEABLE BRICK SECTION
S A N L U I S O B I S P O
C R E E K
S L O M A
RAILING AND
EXISTING WALL
(BEYOND)
EXISTING
SYCAMORE TREES
EXISTING WALL
EXISTING WALL
6'
-
4
"
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
GB
GB
PR
O
P
E
R
T
Y
L
I
N
E
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
LA
N
D
S
C
A
P
E
S
I
T
E
S
E
C
T
I
O
N
/ MP
AWB MPSITE SECTION A
0
SCALE:
feet4812
1/4" = 1'-0"
SECTION KEYMAP
A
L-201
03/30/2026
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
MA
T
E
R
I
A
L
S
A
N
D
PL
A
N
T
P
A
L
E
T
T
E
L-301
/ MP
EE MP
WC-01 CONCRETE PLANTER WALL
WITH WOOD SEAT WC-02 CONCRETE FLUSH CURB - 8" WIDE WC-03 WEATHERING STEEL PLANTER
WITH WOOD SEAT
WC-04 WEATHERING STEEL PLANTER EDGING
TREX DECKING
DECK RAILINGPL-01 3/8" GRAVEL MULCH FR-02 PERFORATED STEEL EQUIPMENT SCREEN
BRICK PAVING - PERMEABLE
RE-USE OF EXISTING BRICKS, WITH 1/4"
JOINTS FILLED WITH NO. 8 STONE
PA-01
SITE FURNISHINGS AND MATERIALS
PLANT PALETTE
ACACIA COGNATA 'COUSIN ITT'
LITTLE RIVER WATTLE
AEONIUM ARBOREUM 'ATROPURPUREUM'
PURPLE TREE AEONIUM
ASPARAGUS DENSIFLORUS 'MYERS'
MYERS ASPARAGUS FERN
CAREX DIVULSA
EUROPEAN GREY SEDGE
FICUS PUMILA
CREEPING FIG
PARTHENOCISSUS TRICUSPIDATA
BOSTON IVY
POLYSTICHUM MUNITUM
WESTERN SWORD FERN
SEDUM 'AUTUMN JOY'
AUTUMN JOY SEDUM
SENECIO RADICANS 'FISHHOOKS'
SENECIO FISHHOOKS
STRELITZIA REGINAE
BIRD OF PARADISE
TRACHELOSPERMUM JASMINOIDES
CHINESE STAR JASMINE
FR-03WC-05 DEEPENED CURB WITH BRICK BAND,
MORTARED
CONCRETE PAVINGBRICK PAVING
RE-USE OF EXISTING BRICKS,
SAND-SET
PA-04PA-02 PA-03
CORDYLINE X 'RENEGADE'
RENEGADE CORDYLINE
03/30/2026
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER PCB PCB-25
FLOOD BUBBLER, 1/2IN. FIPT.
10/L-402
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICZ-101-25
DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH
1IN. HY100 FILTER SYSTEM. PRESSURE REGULATION:
25PSI. FLOW RANGE: 2 GPM TO 20 GPM. 150 MESH
STAINLESS STEEL SCREEN.
5/L-402
PIPE TRANSITION POINT ABOVE GRADE
PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP
TUBING WITH RISER TO ABOVE GRADE INSTALLATION.
8/L-402
HUNTER PLD-BV
MANUAL FLUSH/SHUT OFF VALVE, BARBED INSERT.
TYPICALLY INSTALLED IN 10IN. BOX, WITH ADEQUATE
BLANK TUBING TO EXTEND VALVE OUT OF VALVE BOX.
USE WITH HDL OR OTHER 3/4IN. DRIPLINE.
7/L-402
HUNTER PLD-AVR
PLD-AVR ALLOWS FOR AIR TO ESCAPE A RESIDENTIAL
DRIP IRRIGATION SYSTEM TO PREVENT BLOCKAGE AND
WATER HAMMERING. 1/2IN. MPT CONNECTION WITH 80
PSI MAXIMUM RATING.
12/L-402
AREA TO RECEIVE DRIP EMITTERS
HUNTER HE-B
POINT SOURCE DRIP EMITTER WITH SELF PIERCING BARB.
COLOR CODED EMITTERS FOR FLOW RATES OF 0.5 GPH,
1.0 GPH, 2.0 GPH, 4.0 GPH, AND 6.0 GPH. CAN BE
INSERTED INTO 1/2IN. AND 3/4IN. TUBING AND HAVE
PRESSURE COMPENSATING FROM 15 PSI-50 PSI.
OPTIONAL DIFFUSER CAP (HE) AVAILABLE.
11/L-402
20 emitters (2 assigned to each 1 gal plant)
20 emitters (2 assigned to each 5 gal plant)
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICV-G
1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT
THREADED INLET/OUTLET, FOR
COMMERCIAL/MUNICIPAL USE.
6/L-402
HUNTER HQ-44RC
QUICK COUPLER VALVE, YELLOW RUBBER COVER, RED
BRASS AND STAINLESS STEEL, WITH 1IN. NPT INLET,
2-PIECE BODY.
14/L-402
LANDSCAPE PRODUCTS INC. CWV THREADED
1/2IN., 3/4IN., 1IN., 1-1/4IN., 1-1/2IN.,2IN. THREADED
PLASTIC BALL VALVE. QUARTER-TURN SHUTOFF
DESIGNED FOR IRRIGATION, SPAS, POOLS AND OTHER
GENERAL COLD WATER APPLICATIONS. 125 PSI RATING.
SAME SIZE AS MAINLINE.
4/L-402
HUNTER ICV-G MASTER VALVE 1"
1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC MASTER VALVE,
GLOBE CONFIGURATION, WITH NPT THREADED
INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE.
2/L-402
FEBCO 825Y LF 1"
REDUCED PRESSURE BACKFLOW PREVENTER
1/L-402
HUNTER NODE-BT-200
2-STATION BLUETOOTH CONTROLLER, OUTDOOR,
BATTERY POWERED.
5/L-402
HUNTER MINI-CLIK
RAIN SENSOR, MOUNT AS NOTED IN DETAIL
13/L-402
HUNTER HFS-100
FLOW SENSOR FOR USE WITH ACC CONTROLLER, 1IN.
SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP.
3/L-402
STRONG BOX SBBC-22CR
LOW PROFILE, TUBE AND WIRE CONSTRUCTION
SMOOTH TOUCH SURFACE, COLD ROLLED STEEL,
BACKFLOW ENCLOSURE. 23.5IN.L, 28IN.H, 17.75IN.W.
1/L-402
POINT OF CONNECTION 1"
TIE INTO EXISTING POINT OF CONNECTION ON SITE,
ASSUME 75 PSI TO BE VERIFIED IN FIELD,
WATER PURVEYOR: CITY OF SAN LUIS OBISPO
IRRIGATION LATERAL LINE: PVC SCHEDULE 40
IRRIGATION MAINLINE: PVC SCHEDULE 40
PIPE SLEEVE: PVC SCHEDULE 40
F
A
MV
BF
C
RS
FS
SB
POC
#"
#
Valve Number
Valve Size
Valve Flow
Valve Callout
#
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
IR
R
I
G
A
T
I
O
N
S
C
H
E
D
U
L
E
,
N
O
T
E
S
,
AN
D
M
W
E
L
O
C
A
L
C
U
L
A
T
I
O
N
S
/ MP
AWB MP
1.ALL IRRIGATION EQUIPMENT SHALL BE INSTALLED PER THESE DRAWINGS AND
MANUFACTURER'S RECOMMENDATIONS. IF CONFLICTS OCCUR, MANUFACTURER'S
DETAILS SHALL TAKE PRECEDENCE.
2.IRRIGATION PLAN IS DIAGRAMMATIC. FINAL LOCATION OF PIPING WILL BE DETERMINED
AT THE TIME OF INSTALLATION. MAINLINE AND LATERALS SHALL BE PLACED IN THE SAME
TRENCH WHEN POSSIBLE. ALL Q.C. VALVES ARE TO BE LOCATED 12" FROM SIDEWALKS,
CURBS, ASPHALT & CONCRETE SURFACES.
3.ALL EQUIPMENT REQUIRED BUT NOT SPECIFIED ON THE DRAWING, TO COMPLETE THE
WORK, SHALL BE PROVIDED BY THE IRRIGATION CONTRACTOR.
4.INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS
AND/OR SPECIFICATIONS.
5.CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE PLANS AND SITE CONDITIONS
PRIOR TO BEGINNING WORK. SHOULD CONFLICTING INFORMATION BE FOUND ON THE
PLANS, THE CONTRACTOR SHALL NOTIFY THE PROJECT LANDSCAPE ARCHITECT BEFORE
PROCEEDING WITH THE WORK IN QUESTION.
6.DO NOT WILLFULLY INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS
WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES OR
DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED
IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO
THE ATTENTION OF THE LANDSCAPE ARCHITECT. IN THE EVENT THIS NOTIFICATION IS NOT
PERFORMED, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY
REVISIONS NECESSARY AT NO EXPENSE TO THE OWNER.
7.SPLICING OF 24 VOLT WIRES WILL NOT BE PERMITTED EXCEPT IN VALVE BOXES. LEAVE A
24" COIL OF EXCESS WIRE AT EACH SPLICE. LABEL ALL WIRES W/ WATERPROOF
MARKERS AT ALL SPLICES AND VALVE MANIFOLDS
8.CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL MATERIAL
APPEARING ON PLAN.
9.PROVIDE PVC SHUTOFF VALVES IN LOCATIONS PER PLAN.
10.ALL EXISTING UTILITIES AND WATER LINES SHALL REMAIN CONNECTED AND IN FULL
CONTINUOUS OPERATION DURING AND FOLLOWING ALL CONTRACT WORK.
11.CONTRACTOR SHALL SLEEVE ALL PIPE CROSSINGS UNDER HARDSCAPE. ALL SLEEVES
SHALL BE TWICE THE DIAMETER OF THE PIPE CARRIED WITHIN. EXTEND ALL SLEEVES 18"
BEYOND EDGE OF HARDSCAPE, TYP.
12.ALL NEW IRRIGATION BOXES, AND ADDITIONAL BOXES SHALL BE LOCATED IN PLANTING
AREAS 18" MIN. AWAY FROM ADJACENT PAVING AND 5' MIN. AWAY FROM IMMEDIATE
BUILDING ENTRIES.
13.FOR ALL DRIP AREAS: CONTRACTOR TO INSTALL AIR RELIEF VALVES AND FLUSH VALVES IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
14.CONTROL VALVE SHALL BE TAGGED WITH IDENTIFICATION TAGS. TAGS SHALL BE
WEATHERPROOF PLASTIC, IMPRINTING SHALL BE PERMANENT AND BLACK IN COLOR.
IRRIGATION NOTES
1.PROJECT INFORMATION - SEE ARCHITECTURE SHEETS FOR ALL INFORMATION INCLUDING, DATE,
PROJECT APPLICANT AND OWNER, AND ADDRESS.
SHRUBS, GRASSES, AND GROUNDCOVERS - 461 SF
TREES (25 SF PER TREE, 5 PROPOSED) - 125 SF
TOTAL ON-SITE LANDSCAPE AREA: 586 SF
ESTIMATED TOTAL WATER USE (ETWU): 6,905 GAL/YR
MAXIMUM APPLIED WATER ALLOWANCE (MAWA): 8,126 GAL/YR
2.PROJECT TYPE - NEW CONSTRUCTION
3.WATER SUPPLY - POTABLE PER CITY OF SAN LUIS OBISPO
4.CHECKLIST OF ALL DOCUMENTS IN LANDSCAPE DOCUMENT PACKAGE:
X LANDSCAPE DESIGN PLAN - INCLUDED IN THESE LANDSCAPE DRAWINGS
X IRRIGATION DESIGN PLAN - INCLUDED IN THESE LANDSCAPE DRAWINGS
X GRADING DESIGN PLAN - PER CIVIL SHEETS
5.WATER BUDGET CALCULATIONS (MAWA) AND (ETWU) - SEE ABOVE AND SPREADSHEET AT LEFT.
6.I AGREE TO COMPLY WITH THE REQUIREMENTS OF MWELO.
___________________________________________________
LANDSCAPE ARCHITECT | CA LICENSE NUMBER #6432
CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING ITEMS:
HTTP://WWW.WATER.CA.GOV/WATERUSEEFFICIENCY/DOCS/MWELO09-10-09.PDF
1.COMPOSTING
INCORPORATE COMPOST AT A RATE OF AT LEAST FOUR CUBIC YARDS PER 1,000 SQUARE FEET
TO A DEPTH OF SIX INCHES INTO LANDSCAPE AREA - UNLESS CONTRA-INDICATED BY A SOILS
REPORT.
2.PLANT MATERIAL
INSTALL CLIMATE ADAPTED PLANTS THAT REQUIRE OCCASIONAL, LITTLE OR NO SUMMER
WATER (AVERAGE WUCOLS PLANT FACTOR 0.3) FOR 75% OF THE PLANT AREA EXCLUDING
EDIBLES AND AREAS USING RECYCLED WATER.
3.IRRIGATION SYSTEM
SHALL COMPLY WITH THE FOLLOWING:
AUTOMATIC IRRIGAITON CONTROLLERS ARE REQUIRED AND MUST USE EVAPOTRANSPIRATION
OR SOIL MOISTURE SENSOR DATA AND UTILIZE A RAIN SENSOR.
IRRIGATION CONTROLLERS SHALL BE A TYPE WHICH DOES NOT LOSE PROGRAMMING DATA IN
THE EVENT THE PRIMARY POWER SOURCE IS INTERRUPTED.
PRESSURE REGULATORS SHALL BE INSTALLED ON THE IRRIGATION SYSTEM O ENSURE THE
DYNAMIC PRESSURE OF THE SYSTEM IS WITHIN THE MANUFACTURES RECOMMENDED PRESSURE
RANGE.
ALL IRRIGAITON EMIISION DVICES MUST MEET THE REQUIREMENTS SET IN THE ANSI STANDARD,
ASABE/ICC 802-2014 “LANDSCAPE IRRIGATION SPRINKLER AND EMITTER STANDARD,” ALL
SPRINKLER HEADS INSTALLED IN THE LANDSCAPE MUST DOCUMENT A DISTRIBUTION
UNIFORMITY LOW QUARTER OF 0.65 OR HIGHER USING THE PROTOCOL DEFINED IN ASABE/ICC
802-2014.
AREAS LESS THAN TEN (10) FEET IN WIDTH IN ANY DIRECTION SHALL BE IRRIGATED WITH
SUBSURFACE IRRIGATION OR OTHER MEANS THAT PRODUCES NO RUNOFF OR OVERSPRAY.
4.FINAL INSPECTION
AT THE TIME OF FINAL INSPECTION, THE CONTRACTOR MUST PROVIDE THE OWNER OF THE
PROPERTY WITH A CERTIFICATE OF COMPLETION, CERTIFICATE OF INSTALLATION, IRRIGATION
SCHEDULE AND A SCHEDULE OF LANDSCAPE AND IRRIGATION MAINTENANCE.
MWELO COMPLIANCE WATER USE CALCULATIONS IRRIGATION SCHEDULE
L-400
03/30/2026
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER PCB PCB-25
FLOOD BUBBLER, 1/2IN. FIPT.
10/L-402
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICZ-101-25
DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH
1IN. HY100 FILTER SYSTEM. PRESSURE REGULATION:
25PSI. FLOW RANGE: 2 GPM TO 20 GPM. 150 MESH
STAINLESS STEEL SCREEN.
5/L-402
PIPE TRANSITION POINT ABOVE GRADE
PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP
TUBING WITH RISER TO ABOVE GRADE INSTALLATION.
8/L-402
HUNTER PLD-BV
MANUAL FLUSH/SHUT OFF VALVE, BARBED INSERT.
TYPICALLY INSTALLED IN 10IN. BOX, WITH ADEQUATE
BLANK TUBING TO EXTEND VALVE OUT OF VALVE BOX.
USE WITH HDL OR OTHER 3/4IN. DRIPLINE.
7/L-402
HUNTER PLD-AVR
PLD-AVR ALLOWS FOR AIR TO ESCAPE A RESIDENTIAL
DRIP IRRIGATION SYSTEM TO PREVENT BLOCKAGE AND
WATER HAMMERING. 1/2IN. MPT CONNECTION WITH 80
PSI MAXIMUM RATING.
12/L-402
AREA TO RECEIVE DRIP EMITTERS
HUNTER HE-B
POINT SOURCE DRIP EMITTER WITH SELF PIERCING BARB.
COLOR CODED EMITTERS FOR FLOW RATES OF 0.5 GPH,
1.0 GPH, 2.0 GPH, 4.0 GPH, AND 6.0 GPH. CAN BE
INSERTED INTO 1/2IN. AND 3/4IN. TUBING AND HAVE
PRESSURE COMPENSATING FROM 15 PSI-50 PSI.
OPTIONAL DIFFUSER CAP (HE) AVAILABLE.
11/L-402
20 emitters (2 assigned to each 1 gal plant)
20 emitters (2 assigned to each 5 gal plant)
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICV-G
1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT
THREADED INLET/OUTLET, FOR
COMMERCIAL/MUNICIPAL USE.
6/L-402
HUNTER HQ-44RC
QUICK COUPLER VALVE, YELLOW RUBBER COVER, RED
BRASS AND STAINLESS STEEL, WITH 1IN. NPT INLET,
2-PIECE BODY.
14/L-402
LANDSCAPE PRODUCTS INC. CWV THREADED
1/2IN., 3/4IN., 1IN., 1-1/4IN., 1-1/2IN.,2IN. THREADED
PLASTIC BALL VALVE. QUARTER-TURN SHUTOFF
DESIGNED FOR IRRIGATION, SPAS, POOLS AND OTHER
GENERAL COLD WATER APPLICATIONS. 125 PSI RATING.
SAME SIZE AS MAINLINE.
4/L-402
HUNTER ICV-G MASTER VALVE 1"
1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC MASTER VALVE,
GLOBE CONFIGURATION, WITH NPT THREADED
INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE.
2/L-402
FEBCO 825Y LF 1"
REDUCED PRESSURE BACKFLOW PREVENTER
1/L-402
HUNTER NODE-BT-200
2-STATION BLUETOOTH CONTROLLER, OUTDOOR,
BATTERY POWERED.
5/L-402
HUNTER MINI-CLIK
RAIN SENSOR, MOUNT AS NOTED IN DETAIL
13/L-402
HUNTER HFS-100
FLOW SENSOR FOR USE WITH ACC CONTROLLER, 1IN.
SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP.
3/L-402
STRONG BOX SBBC-22CR
LOW PROFILE, TUBE AND WIRE CONSTRUCTION
SMOOTH TOUCH SURFACE, COLD ROLLED STEEL,
BACKFLOW ENCLOSURE. 23.5IN.L, 28IN.H, 17.75IN.W.
1/L-402
POINT OF CONNECTION 1"
TIE INTO EXISTING POINT OF CONNECTION ON SITE,
ASSUME 75 PSI TO BE VERIFIED IN FIELD,
WATER PURVEYOR: CITY OF SAN LUIS OBISPO
IRRIGATION LATERAL LINE: PVC SCHEDULE 40
IRRIGATION MAINLINE: PVC SCHEDULE 40
PIPE SLEEVE: PVC SCHEDULE 40
F
A
MV
BF
C
RS
FS
SB
POC
#"
#
Valve Number
Valve Size
Valve Flow
Valve Callout
#
SD
S
D
SD
S
D
SD
S
D
S
D
S
D
S
D
SD
S
D
SD
S
D
S
D
S
D
S
D
SD
S
D
SD
S
D
SD
S
D
S
D
SD
S
D
SD
SD
SD
S
D
S
D
SD
S
D
SD
SD
SD
S
D
S
D
SD
S
D
SD
SD
SD
S
D
S
D
SD
S
D
S
D
S
D
SD
S
D
SD
S
D
S
D
S
D
S
D
S
D
S
D
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
SD
SD
////////
//
//
//
//
//
//
//
//////
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
C O N C R E T E P A D
(N O T A P A R T)
(E) P A R K I N G
L O T
T H E W A R D E N
B L O C K
T O W A R D E N
B R I D G E
W I C K E N D E N
B U I L D I N G
S L O M A
S L O M A
S
A
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
PR
O
P
E
R
T
Y
L
I
N
E
#3
#5
#7#8
#9
#10
#11
#14
110.9
1"
POINT OF CONNECTION
POC
MV
BF
FS
HB
LOCATE EXISTING POC - POTABLE WATER
AVAILABLE PRESSURE: 75 PSI ASSUMED
WATER PURVEYOR: CITY OF SAN LUIS OBISPO
34"
C
3 4"
RS
SB
34"
3 4"
22.5
1"
1"
1"1"
1"
34"
3 4"
34"
3 4"
3 4"
34"
34"34"
34"3 4"
3 4"
BOTH LATERALS IN
SLEEVE SHALL BE
FASTENED UNDER
DECK
APPROXIMATE LOCATION OF NEW HOSE
BIBB, INSTALL ON WATER LINE STUB OUT
FROM BUILDING PER PLUMBING PLANS
BOTH LATERALS IN
SLEEVE SHALL BE
FASTENED UNDER DECK
EXISTING TREE TO
REMAIN, TYP.
INSTALL IRRIGATION CONTROLLER
ON VALVE PER DETAIL 5/L-402
EXERCISE CAUTION WHEN TRENCHING
BENEATH EXISTING TREES. ALL TRENCHING
TO BE HAND DUG. ADJUST LOCATION OF
LATERALS IF ROOTS ARE ENCOUNTERED
DURING TRENCHING, TYP.
INSTALL IRRIGATION WEATHER
SENSOR ON BACK OF STRING
LIGHT POLE, WIRE BACK TO
CONTROLLER
APPROXIMATE LOCATION
OF EXISTING PG&E
ELECTRICAL PANELS
ATRIUM GRATE, SEE
CIVIL SHEETS , TYP.
CATCH BASIN FOR
ROOF DOWNSPOUT,
SEE CIVIL SHEETS , TYP.
CATCH BASIN FOR
ROOF DOWNSPOUT,
SEE CIVIL SHEETS , TYP.
EXISTING SHRUBS
TO REMAIN, TYP.
BOTH LATERALS IN
SLEEVE, TYP.
BORE THROUGH
EXISTING WALL
TO RECEIVE
LATERAL SLEEVE
BOTH LATERALS IN
SLEEVE, TYP.
EXISTING SHRUB
TO REMAIN, TYP.
STRING LIGHT POST
3 4"3 4"
34"
34"
3 4"
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
IR
R
I
G
A
T
I
O
N
P
L
A
N
/ MP
AWB MP
IRRIGATION SCHEDULE
0
SCALE:
feet4812
1/4" = 1'-0"L-401
03/30/2026
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
IR
R
I
G
A
T
I
O
N
D
E
T
A
I
L
S
/ MP
AWB MP
FG
12"
FLOW
BRASS WYE STRAINER
WITH SCREEN
BACKFLOW PREVENTOR
STAINLESS STEEL ENCLOSURE
BRASS UNION,
TYP. (3) PLACES
8" THICK x 12" WIDE CONCRETE
PAD (LENGTH VARIES PER
ENCLOSURE MANUFACTURER)
SLOPE TO DRAIN AT MINIMUM 2%.
FROM WATER
SOURCE
LINE TO SYSTEMS
FLOW
BACKFLOW PREVENTER WITH STEEL ENCLOSURE
1 1/2" = 1'-0"
BRASS NIPPLE - TYPICAL.
(2) PLACES
90% RELATIVE
COMPACTED SUBGRADE
SLEEVE THRU CONCRETE,
TYPICAL.
PRESSURE
REGULATOR
BRASS 90° ELL - TYPICAL
(2) PLACES
BRASS NIPPLE - TYPICAL (4)
PLACES
BACKFLOW PREVENTOR
ASSEMBLY
1/3 CU FT CONCRETE
THRUST BLOCKS - TYPICAL
(2) PLACES
BRASS 90 ELL - TYPICAL (2)
PLACES
1. EQUIPMENT TO BE INSTALLED AT A MINIMUM OF 24" FROM ANY STRUCTURES OR HARDSCAPING.
2. WHEN UNIT IS NEXT TO A STRUCTURE (ie. WALL, BUILDING, ETC.) MOUNT TEST COCKS ON OPEN OR
NON-STRUCTURE SIDE.
12
"
MI
N
.
NOTES:
RED BRASS PIPE
RED BRASS PIPE
RRM-2800-2803.07-43
1
30-INCH LINEAR LENGTH
OF WIRE, COILED
WATER PROOF
CONNECTION (1 OF 2)
ID TAG
VALVE BOX. SET 1" ABOVE FINISH
GRADE IN TURF AREAS. SET 2"
ABOVE FINISH GRADE IN
PLANTER AREAS. SET FLUSH WITH
GRADE IN HARDSCAPE AREAS.
TOP OF GRADE
BRICK (1 OF 4)
SCH 80 MAINLINE PIPE
AND FITTINGS FROM
BACKFLOW
PREVENTOR.
3" MIN. DEPTH OF 3/4" WASHED
CRUSHED AGGREGATE BASE.
ONE (1) CUBIC FT. MIN.
NOTE:
PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX.
PVC UNION
MASTER REMOTE
CONTROL VALVE
CONTROLLER WIRE (WHITE
COMMON)
CONTROLLER WIRE (NON-WHITE
HOT). WIRE TO MASTER VALVE
STATION ON CONTROLLER(S).
TO DISTRIBUTION AREAS
FLOW DIRECTION
SCH 80 PVC
45° ELL
SCH 80 PVC
NIPPLE
SCH 80 PVC NIPPLE
MAINLINE
SIZE PER
PLAN
NATIVE SOIL/TOPSOIL
MASTER VALVE
3/4" = 1'-0"
STANDARD 17"x30" MIN.
15
"
M
I
N
.
2
RRM-2800-2803.07-33
NOTES:
1. CONTRACTOR SHALL WIRE FLOW SENSOR TO IRRIGATION CONTROLLER MODULE.
2. FLOW SENSOR MAKE AND MODEL SHALL BE COMPATIBLE WITH IRRIGATION CONTROLLER.
3. PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX.
FLOW
5 X PIPE DIA.10 X PIPE DIA.
JUMBO PLASTIC VALVE BOX
WITH 2 - 6" EXTENSIONS &
LOCKING COVER.
BRICKS. ONE AT EACH
CORNER OF JUMBO VALVE
BOX.
12" DEEP 3 4" CRUSHED
AGGREGATE BASE
2 CONDUCTOR SHIELDED CABLES.
CONNECT TO TRANSMITTER.
FLOW SENSOR. MATCH
DIRECTION OF FLOW.
SCH 80 PVC MALE ADAPTERS, WHEN
REQUIRED (2).
WATERPROOF CONNECTORS.
FLOW
NO VALVES, REDUCERS,
OR ELBOWS IN THIS AREA
FLOW SENSOR
3/4" = 1'-0"
10" MIN.
10
"
M
I
N
.
5"
TOP OF GRADE
JUMBO VALVE BOX
VALVE BOX EXTENSION
MAINLINE SIZE PER PLAN
3
RRM-2800-2803.07-30
PRESSURIZED MAINLINE PVC PIPE.
12" DEEP 3/4" CRUSHED
AGGREGATE BASE
SCHEDULE 40 PVC
MALE ADAPTER.
COMMON BRICKS FOR
SUPPORT. MIN. THREE.
BALL VALVE. CENTER IN BOX
EXTENSION FOR 12" METER BOX.
SIZE AS REQUIRED.
12" ROUND METER BOX.
NOTES:
1. PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX.
ISOLATION (BALL) VALVE
1" = 1'-0"
TOP OF GRADE
VALVE BOX WITH LOCKABLE LID
4
RRM-2800-2803.07-19
PVC SCH 40 LATERAL LINE TO DRIP
TUBING, 18" LENGTH MINIMUM BEFORE
FIRST FITTING.
VALVE BOX WITH LOCKABLE LID
INLINE PRESSURE REGULATOR
ELECTRIC REMOTE CONTROL VALVE, SEE
IRRIGATION LEGEND FOR TYPE.
COMMON BRICK, ONE AT EACH
CORNER FOR SUPPORT.
TOP OF GRADE
INLINE WYE FILTER, SEE IRRIGATION
LEGEND FOR TYPE.
PRESSURIZED MAINLINE PIPE. SEE PLAN
FOR SIZE
IRRIGATION CONTROLLER (NODE-BT) AND
MOUNTING HARDWARE PER MANUFACTURER COIL
18" LENGTH OF EXCESS CONTROL WIRE AND
SPLICE WITH WATER-TIGHT SPLICE CONNECTORS.
WIRE TO ALL VALVES
12
"
26" (JUMBO)
DRIP ZONE VALVE WITH CONTROLLER
1/2" = 1'-0"
12" DEEP 3/4" CRUSHED
AGGREGATE BASE
ID
T
A
G
SCHEDULE 40 PVC MALE ADAPTER
SCHEDULE 40 PVC MALE ADAPTER
BALL VALVE
5
RRM-2800-2803.07-54
1 1/2" = 1'-0"
DRIP FLUSH VALVE
10" DIAMETER VALVE BOX.
COIL 24" TO 30" OF DRIP TUBING IN THE BOX.
3 4" PVC BALL VALVE WITH SHORT
NIPPLE.
12" DRIP TUBING.
12" DEEP 3/4" CRUSHED AGGREGATE
BASE
12" DRIP TUBING TO 3 4" FPT ADAPTER.
TOP OF GRADE
NOTES:
1. PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX.
7
RRM-2800-2803.07-28
3" = 1'-0"
DRIP AIR RELIEF VALVE IN BOX
3 4"X1"MPT ADAPTER.
1" FPTXMPT ELL.
AS SPECIFIED.
AIR RELIEF VALVE
DRIPLINE OR 1/2" DRIP TUBING.
3 4"FPT X 12" DRIP TUBING
ADAPTER.
DRIP TUBING COUPLING.
6" DRIP BOX.
12" DEEP 3/4" CRUSHED
AGGREGATE BASE
TOP OF GRADE
NOTES:
1. PLACE AGGREGATE PRIOR TO
INSTALLATION OF VALVE BOX.
RRM-2800-2803.07-09
12
1 1/2" = 1'-0"
TYPICAL DRIP TUBING LAYOUT
COMPRESSION FITTING.
PLANT GRAPHIC
DRIPLINE EDGE.
METAL 1/2" DRIP TUBING STAKE.
SINGLE-OUTLET EMITTER WITH BARB INLET.
STAKE EMITTERS AT END OF
LINE ON 12" DRIP STAKE.
TYPICAL
COMPRESSION
FITTING.
NOTES:
A.PLACE EMITTERS 3 4 BETWEEN THE TRUNK AND OUTER DRIPLINE.
B.EVENLY SPACE EMITTERS AROUND PLANT.
C.STAKE THE DRIP TUBING AT EACH TEE, ELL, COUPLER, AT EACH EMITTER OR TRANSFER, AND AT 6'-0"
MAX O.C.
D.1/4" 'SPAGHETTI' TUBING IS NOT PERMITTED.
E.SEE SCHEDULE FOR NUMBER OF EMITTERS PER PLANT.
1/2" FLEXIBLE DRIP TUBING
RRM-2800-2803.07-11
11
MAINLINE COMBINED WITH LATERAL LINE
MAINLINE WITH CONTROL WIRELATERAL LINE
2"
M
I
N
.
4"
CV
R
.
LI
F
T
2
LI
F
T
3
4"
2"
MI
N
.
LI
F
T
3
LI
F
T
2
CV
R
.
12
"
M
I
N
.
F
O
R
LA
T
E
R
A
L
S
LATERAL LINE
TRACER TAPE
3 x's DIA
OF MAINLINE
SAND COVER
PRESSURE LINE
POSITION CONTROL WIRES
IN LOWER LEFT OR RIGHT
HAND QUADRANT OF
MAINLINE. TAPE WIRE AT 10'
INTERVALS; DO NOT SECURE
TO MAINLINE.
SAND BED
3 x's DIA
OF LATERAL
LINE
WATER JET BEDDING
AND BACKFILL FOR
PIPELINE
INSTALLATION.
TYPICAL FOR ALL
NATURAL EARTH
BACKFILL.
LATERAL LINE
TRACER TAPE
SAND COVER
PRESSURE (MAIN)LINE
POSITION CONTROL WIRES
IN LOWER LEFT OR RIGHT
HAND QUADRANT OF
MAINLINE. TAPE WIRE AT 10'
INTERVALS; DO NOT SECURE
TO MAINLINE.
SAND BED
3 X'S DIA. OF
MAINLINE
NOTES:
1. PIPE BEDDING AND BACKFILL SHALL BE
WATER JETTED TO ACHIEVE PROPER
DENSIFICATION.
2. PIPE AND CONTROL WIRE CROSSING
VECHICULAR ROADWAY SHALL BE SLEEVED
PER PLANS AND THIS DETAIL
3. ELECTRICAL SLEEVE: 3" MIN; LARGER IF
REQUIRED BY INSPECTOR.
4. IRRIGATION SLEEVE: TWO PIPE SIZES LARGER
THAN WATER PIPE SIZE.
5. SHOW ALIGNMENT OF ALL CONTROL WIRE
NOT INSTALLED WITH MAINLINE ON AS-BUILT
DRAWINGS.
FG
CONTROL WIRE
SEPARATE FROM PIPE
SA
M
E
A
S
L
A
T
E
R
A
L
TRACER TAPE
1/2" CLASS 315
P.V.C. PIPE
(NOT AN
IRRIGATION
LINE)
DE
P
T
H
WIRE TAPED AT
10' O.C. TO
LOWER HALF OF
PIPE
30
"
F
O
R
M
A
I
N
L
I
N
E
4
"
A
N
D
U
P
24
"
F
O
R
M
A
I
N
L
I
N
E
U
P
T
O
3
"
30
"
F
O
R
M
A
I
N
L
I
N
E
4
"
A
N
D
U
P
24
"
F
O
R
M
A
I
N
L
I
N
E
U
P
T
O
3
"
BACKFILL MATERIAL
12
"
BACKFILL MATERIAL
TRENCHING
1" = 1'-0"9
RRM-2800-2803.07-35
3" = 1'-0"
RIGID PVC TO DRIPLINE TRANSITION
1/2" DRIP TUBING.
3 4"FPT X 12" DRIP
TUBING ADAPTER.
COMPRESSION TEE.
6" DRIP BOX.
3 4" SCHEDULE 80 NIPPLE AS
REQUIRED.
PVC LATERAL LINE.
12" DEEP 3/4" CRUSHED
AGGREGATE BASE
TOP OF GRADE
NOTES:
1. PLACE AGGREGATE PRIOR TO
INSTALLATION OF VALVE BOX.
RRM-2800-2803.07-25
8
WIRELESS WEATHER SENSOR
1/2" = 1'-0"
WEATHER SENSOR.
BUILDING
(OPTION #1)
MOUNTING BRACKET
PER MANUFACTURER.
FENCE
(OPTION #2)
POST PER PLAN.
(OPTION #3)
6'
-
0
"
NOTES:
1. INSTALL WEATHER SENSOR CLEAR FROM OVERHEAD PROJECTIONS AT A MINIMUM ELEVATION OF 6' FROM THE
GROUND. UTILIZE MANUFACTURER'S ACCESSORY CLIPS AND MOUNTING EQUIPMENT.
2. WEATHER SENSOR SHALL BE INSTALLED ON BUILT STRUCTURES PER OPTION #1 WHERE POSSIBLE. WHERE NO BUILT
STRUCTURES ARE AVAILABLE, INSTALLATION SHALL BE PER OPTION #2. OPTION #3 SHALL BE UTILIZED ONLY WHEN THE
OTHER TWO OPTIONS ARE NOT VIABLE.
3. INSTALL WEATHER SENSOR WITHIN RANGE OF RECEIVER MODULE.
RRM-2800-2803.07-22
13
1 1/2" = 1'-0"
QUICK COUPLING VALVE IN BOX
FL
U
S
H
I
N
L
A
W
N
A
R
E
A
S
.
2"
I
N
S
H
R
U
B
A
R
E
A
S
.
NIPPLE
12" PVC SCHEDULE 80
12" MAX
QCV
2"
M
A
X
.
1"
M
I
N
.
6" MIN.
STEEL CLAMPS
TWO STAINLESS
THREE PVC SCH 80
ELLS.
STEEL PIPE
1/2" X 36" GALV
NIPPLE
3" PVC SCHEDULE 80
GALV. NIPPLE, LENGTH AS REQ.
AGGREGATE BASE
12" DEEP 3/4" CRUSHED
SPECIFIED
QUICK COUPLING VALVE AS
TOP OF GRADE
WITH 2" HIGH CHARACTERS
HEAD BRAND "QCV" ON LID
10" DIAMETER VALVE BOX.
NOTES:
1. PLACE AGGREGATE
PRIOR TO INSTALLATION
OF VALVE BOX.
RRM-2800-2803.07-12
14
L-402
SCH 80 NIPPLE (2-INCH LENGTH,
HIDDEN) AND SCH 40 ELL
24-INCH LINEAR LENGTH OF
WIRE, COILED
WATER PROOF CONNECTION (1 OF 2)
ID TAG
4"
MA
X
.
VALVE BOX WITH LOCKABLE LID
TOP OF GRADE
REMOTE CONTROL VALVE
PVC SCH 80 NIPPLE. SIZE PER
PLAN. LENGTH AS REQUIRED.
BRICK (1 OF 4)
SCH 40 PVC ELL FITTING
PVC MAINLINE PIPE
PVC SCH 40 TEE OR ELL
PVC SCH 40 MALE ADAPTER
PVC UNION
12" DEEP 3/4" CRUSHED
AGGREGATE BASE
NOTES:
1. PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX.
BALL VALVE (LINE SIZED)
REMOTE CONTROL VALVE
1" = 1'-0"RRM-2800-2803.07-97
6
PLAN VIEW
TREE BUBBLERS
1/2" = 1'-0"
B B
1/2" FNPT BUBBLERS, 2 PER TREE.
LOCATE ON OPPOSITE SIDE OF
WOOD STAKES. ADJUST TO WET
THE ROOT BALL AND AMENDED
SOIL AREA WITHOUT SPRAYING
THE TRUNK OF TREE.
1/2 " FUNNY PIPE. LENGTH VARIES
(SUBGRADE)
PVC TEE FITTING (SUBGRADE)
PVC LATERAL LINE FROM REMOTE
CONTROL VALVE (SUBGRADE)
ROOT BALL OF TREE
AMENDED BACKFILL MIX
PER PLANTING PLANS
WOOD LODGEPOLES,
PER PLANTING PLANS,
WHERE APPLICABLE
CROWN OF TREE
PVC ELL FNPT / SLIP FITTING
(SUBGRADE)
1/2 " FUNNY PIPE WITH MALE
THEADED 1/2" MNPT / 1/2" BARB
FITTINGS, EACH END. 30" EXPOSED
ABOVE GROUND MIN. TO ALLOW
FOR ADJUSTMENT AS TREE
MATURES. USE SOD STAPLES TO
SECURE 1/2" FUNNY PIPE TO SOIL
SURFACE AT 18" O.C. MAX.
10
RRM-2800-2803.07-76
03/30/2026
SYMBOL QTY BOTANICAL NAME COMMON NAME CONT WUCOLS
TREES
1 ACER MACROPHYLLUM BIG LEAF MAPLE 24" BOX LOW
1 HYMENOSPORUM FLAVUM SWEETSHADE 24" BOX LOW
1 PLATANUS RACEMOSA 'ROBERTS'ROBERTS CALIFORNIA SYCAMORE 36" BOX MODERATE
1 PRUNUS ILICIFOLIA HOLLYLEAF CHERRY 24" BOX LOW
1 UMBELLULARIA CALIFORNICA BAY LAUREL 24" BOX LOW
SHRUBS
8 ACACIA COGNATA 'COUSIN ITT'LITTLE RIVER WATTLE 1 GAL LOW
31 AEONIUM ARBOREUM `ATROPURPUREUM`PURPLE TREE AEONIUM 1 GAL LOW
13 ASPARAGUS DENSIFLORUS 'MYERS'MYERS ASPARAGUS FERN 5 GAL MODERATE
42 CAREX DIVULSA EUROPEAN GREY SEDGE 1 GAL LOW
6 CORDYLINE X 'RENEGADE'RENEGADE CORDYLINE 1 GAL LOW
5 FICUS PUMILA CREEPING FIG 1 GAL MODERATE
5 PARTHENOCISSUS TRICUSPIDATA BOSTON IVY 1 GAL LOW
9 POLYSTICHUM MUNITUM WESTERN SWORD FERN 1 GAL MODERATE
6 SEDUM X 'AUTUMN JOY'AUTUMN JOY SEDUM 1 GAL LOW
9 SENECIO RADICANS `FISHHOOKS`SENECIO FISHHOOKS 1 GAL LOW
2 STRELITZIA REGINAE BIRD OF PARADISE 5 GAL MODERATE
4 TRACHELOSPERMUM JASMINOIDES CHINESE STAR JASMINE 5 GAL MODERATE
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
PL
A
N
T
I
N
G
D
E
T
A
I
L
S
A
N
D
N
O
T
E
S
/ MP
AWB MP
PLANTING SCHEDULE
1.CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE PLANS AND SITE CONDITIONS PRIOR TO
BEGINNING WORK. SHOULD CONFLICTING INFORMATION BE FOUND ON THE PLANS, THE
CONTRACTOR SHALL NOTIFY THE PROJECT LANDSCAPE ARCHITECT BEFORE PROCEEDING WITH
THE WORK IN QUESTION.
2.PLANT LIST IS FOR CONVENIENCE OF CONTRACTOR ONLY. IN CASE OF DISCREPANCIES BETWEEN
THE PLANS AND THE LIST, PLANS SHALL PREVAIL. PLANT LOCATIONS SHOWN ON THE PLANS ARE
DIAGRAMMATIC. CONTRACTOR SHALL LOCATE ALL PLANT MATERIAL UNDER THE DIRECTION OF
THE AUTHORIZED REPRESENTATIVE PRIOR TO PLANTING HOLE EXCAVATION.
3.THE REPRESENTATIVE RESERVES THE RIGHT TO MAKE SUBSTITUTIONS, ADDITIONS, AND DELETIONS TO
THE PLANTING LAYOUT AS WORK PROGRESSES.
4.ALTERNATE DROUGHT TOLERANT PLANTS ARE ACCEPTABLE BASED UPON APPROVAL FROM
AUTHORIZED REPRESENTATIVE.
5. BACKFILL PLANTING HOLES WITH MIXTURE OF 50% EXISTING SOIL AND 50% COMPOST. ALL
LANDSCAPED AREAS TO RECEIVE MIN. 3" GRAVEL MULCH.
6.PLANT LOCATIONS ON THE PLANS ARE DIAGRAMMATIC. CONTRACTOR SHALL LOCATE ALL PLANT
MATERIAL UNDER THE SUPERVISION THE AUTHORIZED REPRESENTATIVE PRIOR TO PLANTING HOLE
EXCAVATION.
7.REPRESENTATIVE RESERVES THE RIGHT TO MAKE SUBSTITUTIONS, ADDITIONS, AND DELETIONS TO THE
PLANTING LAYOUT AS WORK PROGRESSES.
8.CONTRACTOR TO VERIFY IRRIGATION EQUIPMENT IS IN SUFFICIENT WORKING ORDER PRIOR TO
INSTALLATION OF PLANT MATERIALS.
9.CONTRACTOR SHALL NOT INSTALL ANY PLANTING UNTIL THE FOLLOWING ARE COMPLETED: 1. THE
IRRIGATION SYSTEM SHALL BE FULLY OPERATIONAL. 2. HYDROSTATIC PRESSURE TESTS SHALL BE
PERFORMED ON MAIN AND LATERAL LINES. 3. CONTROLLER SHALL BE FULLY OPERATIONAL.
10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PUBLIC AND PRIVATE
PROPERTY IN THE VICINITY OF HIS WORK, AND SHALL EXERCISE DUE CAUTION TO ITS ORIGINAL
CONDITION, ALL IMPROVEMENTS OR PROPERTY WHICH IS DAMAGED OR REMOVED (UNLESS
DESIGNATED FOR REMOVAL ON THE PLANS) AS A RESULT OF HIS OPERATIONS.
11.THE CONTRACTOR SHALL BE RESPONSIBLE DURING CONSTRUCTION FOR CLEANING CITY/STATE
STREETS, CURBS, GUTTERS AND SIDEWALKS OF DIRT TRACKED FROM THE SUBJECT SITE. THE
FLUSHING OF DIRT AND DEBRIS TO SAN LUIS OBISPO CREEK, STORM DRAIN OR SANITARY SEWER
FACILITIES SHALL NOT BE PERMITTED. THE CLEANING SHALL BE DONE AFTER EACH DAY'S WORK OR
AS DIRECTED BY THE CITY.
PLANTING NOTES
112 x
H
E
I
G
H
T
OF
R
O
O
T
B
A
L
L
AMENDED BACKFILL SOIL MIXTURE2x ROOTBALL
WIDTH
VINE PLANTING
1" = 1'-0"
HOLD ROOTBALL CLOSE TO
FOOTING. REMOVE OVERPOUR
AS NEEDED. KEEP MULCH CLEAR
OF PLANT BASE
BUILDING EDGE
REMOVE NURSERY STAKE.
ENTWINE VINE ON NEW STAKE.
LEAN STAKE AGAINST FINISHED
SURFACE
PLANTING TABLET
ADJACENT SURFACE PER PLAN
AMENDED NATIVE SOIL
FS
RRM-2800-2803.07-13
1
2x ROOTBALL WIDTH
1"
MULCH PER PLANTING NOTES
AMENDED BACKFILL
SOIL MIXTURE
FERTILIZER TABLET
AMENDED NATIVE SOIL
TOP OF ROOTBALL AT OR SLIGHTLY
ABOVE FINISH GRADE
SHRUB PLANTING
1 1/2" = 1'-0"RRM-2800-2803.07-15
2
EQ
U
A
L
E
Q
U
A
L
EQUAL
1/2 O.C. SPACING FROM
EDGE OF PAVING, BACK OF
CURB, OR BUILDING FACE
NOTE: SHRUBS SHALL
BE TRIANGULARLY SPACED
PER THE ON-CENTER (O.C.)
SPACING INDICATED ON THE
PLANTING PLAN AND/OR
PLANTING LEGEND, UNLESS
OTHERWISE NOTED.
EDGE OF PLANTING AREA
PLANT PER PLANTING
PLAN, TYP.
SHRUB SPACING
1 1/2" = 1'-0"3
RRM-2800-2803.07-29
PLANTING DETAILS
L-500
2
03/30/2026
SYMBOL QTY BOTANICAL NAME COMMON NAME CONT WUCOLS
TREES
1 ACER MACROPHYLLUM BIG LEAF MAPLE 24" BOX LOW
1 HYMENOSPORUM FLAVUM SWEETSHADE 24" BOX LOW
1 PLATANUS RACEMOSA 'ROBERTS'ROBERTS CALIFORNIA SYCAMORE 36" BOX MODERATE
1 PRUNUS ILICIFOLIA HOLLYLEAF CHERRY 24" BOX LOW
1 UMBELLULARIA CALIFORNICA BAY LAUREL 24" BOX LOW
SHRUBS
8 ACACIA COGNATA 'COUSIN ITT'LITTLE RIVER WATTLE 1 GAL LOW
31 AEONIUM ARBOREUM `ATROPURPUREUM`PURPLE TREE AEONIUM 1 GAL LOW
13 ASPARAGUS DENSIFLORUS 'MYERS'MYERS ASPARAGUS FERN 5 GAL MODERATE
42 CAREX DIVULSA EUROPEAN GREY SEDGE 1 GAL LOW
6 CORDYLINE X 'RENEGADE'RENEGADE CORDYLINE 1 GAL LOW
5 FICUS PUMILA CREEPING FIG 1 GAL MODERATE
5 PARTHENOCISSUS TRICUSPIDATA BOSTON IVY 1 GAL LOW
9 POLYSTICHUM MUNITUM WESTERN SWORD FERN 1 GAL MODERATE
6 SEDUM X 'AUTUMN JOY'AUTUMN JOY SEDUM 1 GAL LOW
9 SENECIO RADICANS `FISHHOOKS`SENECIO FISHHOOKS 1 GAL LOW
2 STRELITZIA REGINAE BIRD OF PARADISE 5 GAL MODERATE
4 TRACHELOSPERMUM JASMINOIDES CHINESE STAR JASMINE 5 GAL MODERATE
SD
S
D
SD
S
D
S
D
SD
S
D
SD
S
D
SD
S
D
S
D
SD
S
D
S
D
S
D
SD
SD
S
D
SD
S
D
S
D
S
D
SD
SD
S
D
SD
S
D
S
D
S
D
SD
SD
SD
S
D
S
D
S
D
S
D
SD
SD
SD
S
D
SD
S
D
S
D
SD
S
D
SD
SD
SD
S
D
S
D
S
D
S
D
SD
SD
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
D
SD
SD
SD
S
D
SD
SD
SD
SD
SD
SD
////////
//
//
//
//
//
//
//
//////
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
C O N C R E T E P A D
(N O T A P A R T)
(E) P A R K I N G
L O T
T H E W A R D E N
B L O C K
T O W A R D E N
B R I D G E
W I C K E N D E N
B U I L D I N G
S L O M A
S L O M A
S
A
N
L
U
I
S
O
B
I
S
P
O
C
R
E
E
K
GB
GB
PR
O
P
E
R
T
Y
L
I
N
E
#3
#5
#7#8
#9
#10
#11
#14
EXISTING PALM TREES SHALL
BE PRUNED AND CLEANED OF
DEAD WOOD/ DEBRIS, TYP.
ALL EXISTING TREES SHALL BE
PRUNED AND CLEANED OF
DEAD WOOD/ DEBRIS, TYP.
EXERCISE CAUTION WHEN
DIGGING BENEATH EXISTING TREES.
ADJUST LOCATIONS OF SHRUBS IF
ROOTS ARE ENCOUNTERED
DURING DIGGING, TYP.
10
.
5
'
4.
5
'
16
.
5
'
7.
5
'
19
'
2
1
.
5
'
4.
5
'
EXISTING TREE TO
REMAIN, TYP.
APPROXIMATE LOCATION
OF EXISTING PG&E
ELECTRICAL PANELS
ATRIUM GRATE, SEE
CIVIL SHEETS , TYP.
CATCH BASIN FOR
ROOF DOWNSPOUT,
SEE CIVIL SHEETS , TYP.
CATCH BASIN FOR
ROOF DOWNSPOUT,
SEE CIVIL SHEETS , TYP.
EXISTING SHRUB
TO REMAIN, TYP.
STRING LIGHT POST
T H E W A R D E N
B L O C K
rrmdesign.com |(805) 543-1794
CONSULTANT
AGENCY
NO.REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
RRM DESIGN GROUP COPYRIGHT 2026
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
8
0
3
-
0
4
-
S
L
O
M
A
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
/
S
L
O
M
A
_
N
e
t
w
o
r
k
R
e
n
o
v
a
t
i
o
n
.
r
v
t
10
/
2
7
/
2
0
2
5
3
:
2
5
:
0
5
P
M
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
SL
O
M
A
-
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
77
8
-
7
8
6
H
I
G
U
E
R
A
S
T
.
SA
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
2803-07-PS25
MARCH 24, 2026
DG
PLAN CHECK 1 03/02/261
PLAN CHECK 2 03/24/262
PL
A
N
T
I
N
G
P
L
A
N
/ MP
AWB MP
PLANTING SCHEDULE
0
SCALE:
feet4812
1/4" = 1'-0"L-501
CRITICAL ROOT ZONE PER
TREE PROTECTION PLAN,
L-100
03/30/2026
DP1
DP4
DP6
DP8
DP10
5'-1
"
±
3
"
5'-1
"
±
3
"
5'-9
"
±
3
"
8'-0
"
±
3
"
8'-0
"
±
3
"
8'-0
"
±
3
"
8'-0
"
±
3
"
8'-0
"
±
3
"
8'-1
0
"
±
3
"
8'-0
"
±
3
"
8'-0
"
±
3
"
8'-0
"
±
3
"
26'
-
0
"
±
3
"
6'-0
"
±
3
"
8'-0
"
±
3
"
9'-0
"
±
3
"
4'-0
"
UPSLOPE FACE OF (E)
STONE WALL
3'-41
2" ±
3
"
CUT END OF
(E) STONE WALL
(E) STONE WALL
TO REMAIN
(E) STONE WALL
TO REMAIN
6x6 POST
6x6 POST
6x6 POST
6x6 POST
6x6 POST
6x6 POST
6x6 POST
6x6 POST
6x6 POST
DP3
DP5
DP7
DP9
B1
6x6 POST
DP2
8'-0
"
±
3
"
N:
\
2
8
0
0
\
2
8
0
3
-
0
7
-
P
S
2
5
-
S
L
O
M
A
-
T
I
-
C
D
s
\
S
t
r
u
c
t
u
r
a
l
\
C
o
n
D
o
c
s
\
S
h
e
e
t
-
F
i
l
e
s
\
2
8
0
3
-
0
7
-
P
S
2
5
-
P
l
a
n
s
_
D
e
c
k
.
d
w
g
,
S
2
4
1
,
M
a
r
3
0
,
2
0
2
6
1
1
:
3
7
a
m
,
j
d
l
o
n
g
CONSULTANT
RRM DESIGN GROUP COPYRIGHT 2026.
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
rrmdesign.com | (805) 543-1794
AGENCY
PROJECT MANAGER
DRAWN BY
PROJECT NUMBER
CHECKED BY
SHEET
12/17/2025
2803-07-PS25
DATE
NO.REVISION DATE
SL
O
M
A
-
N
E
T
W
O
R
K
R
E
N
O
V
A
T
I
O
N
77
8
H
I
G
U
E
R
A
S
T
.
S
A
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
1 PLAN CHECK 1 03/02/26
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
J. LONG
J. MEADOWS
J. MEADOWS
E
R
P
R
No. 6488
S
T UC T U R A L
S
TAT
OF C A L I F O R NIA
EGISTERE D R O F E SS IONALEN
G
I
N
E
E
RJESSICAM.MEA
D
O
W
S
PRELIMI
N
A
R
Y
NOT FOR
C
O
N
S
T
R
U
C
T
I
O
N
2 PLAN CHECK 2 04/09/26
1 SLOMA DECK FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
NORTH
SL
O
M
A
D
E
C
K
F
O
U
N
D
A
T
I
O
N
P
L
A
N
A.REFER TO THE FOLLOWING SHEETS FOR TYPICAL DETAILS:
B.SEE CIVIL DRAWINGS FOR FINISHED SURFACE ELEVATIONS.
C.ALL DIMENSIONS SHOWN ARE FROM CENTERLINE OF HELICAL PILE & POST, UNO.
D.FOR ANY DIMENSIONAL INFORMATION NOT SHOWN, SEE LANDSCAPE ARCHITECTURAL
DRAWINGS.
E.SEE LANDSCAPE ARCHITECTURAL DRAWINGS FOR ANY EMBEDDED ITEMS AND ALL EXTERIOR
CONCRETE PAVING.
F.SEE ARCHITECTURAL, LANDSCAPE ARCHITECTURAL, PLUMBING, MECHANICAL AND
ELECTRICAL DRAWINGS FOR ADDITIONAL EMBEDDED ITEMS.
G.BOTTOM OF FOOTING SHALL BE, UNLESS DEEPER FOUNDATIONS ARE REQUIRED BY THE
BUILDING OFFICIAL:
1.24" BELOW ADJACENT GRADE
SYMBOL LEGEND
DESCRIPTION SHEET (S)
SYMBOLS AND ABBREVIATIONS S-101
STRUCTURAL GENERAL NOTES S-102 - S-103
TESTING AND INSPECTION S-104
TYPICAL CONCRETE DETAILS S-301
TYPICAL MASONRY DETAILS S-401
TYPICAL STEEL DETAILS S-501
TYPICAL WOOD DETAILS S-601 - S-602
INDICATES (N) HELICAL PIER
DECK FOUNDATION NOTES
DECK FOUNDATION SCHEDULES
PIER SCHEDULE
PIER #DESIGN
DOWNFORCE -
SERVICE LEVEL
PILE MODEL A.B.
CHANCE
(ICC ESR-2794)
TRANSITION
COUPLER MODEL
A.B. CHANCE
(N) CONST
PILE CAP MODEL
A.B. CHANCE
DETAIL
REFERENCE
LEAD EXTENSION
DP1 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP2 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP3 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP4 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP5 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP6 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP7 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP8 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP9 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DP10 11,000 LBS SS175 RS3500 C1500937 C1501357 15/S-243
DECK BEAM SCHEDULE
MARK SIZE REMARKS
B1 6x14 PTDF
INDICATES (N) HELICAL TIEBACK PIER
S-241 1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
FO
R
R
E
F
E
R
E
N
C
E
O
N
L
Y
03/30/2026
J1
B2
B1
B2
B3
B3
B1
B1
B2
B2
B2
B2
J1
J1
J1
J1
J1
J1
13
S-2
4
3
13
S-243
13
S-2
4
3
35
S-2
4
3
33
S-2
4
3
SIM
4
S
I
D
E
S
OF
O
P
N
G
(E) STONE WALL
TO REMAIN
(E) STONE WALL
TO REMAIN
B3
L
E
D
G
E
R
2 B
A
Y
S
M
I
N
W/
N
O
A
B
B2
R
I
M
J
O
I
S
T
RI
M
J
O
I
S
T
S
H
A
L
L
R
U
N
C
O
N
T
4'-0
"
M
I
N
4'-0
"
M
I
N
POST BEL
POST BEL
P
O
S
T
B
E
L
POST BEL
POST BEL
POST BEL
POST BEL
POST BEL
33
S-2
4
3
SI
M
4
S
I
D
E
S
OF
O
P
N
G
POST BEL
DP11
DP12
DP13
DP14
DP15
DP16
DP17
DP18
TP1
TP2
TP3
TP4
B3
B2
@
T
I
E
B
A
C
K
B2
@
T
I
E
B
A
C
K
B2
@
T
I
E
B
A
C
K
B2
@
T
I
E
B
A
C
K
CA
N
T
I
L
E
V
E
R
E
D
B
E
A
M
S
H
A
L
L
R
U
N
C
O
N
T
O
V
E
R
2
P
O
S
T
S
M
I
N
POST BEL
J2
LE
D
G
E
R
S
H
A
L
L
R
U
N
C
O
N
T
4 B
A
Y
S
MI
N
B3
L
E
D
G
E
R
B3
J2
2 B
A
Y
S
M
I
N
W/
N
O
A
B
LE
D
G
E
R
S
H
A
L
L
R
U
N
C
O
N
T
4 B
A
Y
S
MI
N
B3
L
E
D
G
E
R
55
S-2
4
3
35
S-2
4
3
N:
\
2
8
0
0
\
2
8
0
3
-
0
7
-
P
S
2
5
-
S
L
O
M
A
-
T
I
-
C
D
s
\
S
t
r
u
c
t
u
r
a
l
\
C
o
n
D
o
c
s
\
S
h
e
e
t
-
F
i
l
e
s
\
2
8
0
3
-
0
7
-
P
S
2
5
-
P
l
a
n
s
_
D
e
c
k
.
d
w
g
,
S
2
4
2
,
M
a
r
3
0
,
2
0
2
6
1
1
:
3
7
a
m
,
j
d
l
o
n
g
CONSULTANT
RRM DESIGN GROUP COPYRIGHT 2026.
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
rrmdesign.com | (805) 543-1794
AGENCY
PROJECT MANAGER
DRAWN BY
PROJECT NUMBER
CHECKED BY
SHEET
12/17/2025
2803-07-PS25
DATE
NO.REVISION DATE
SL
O
M
A
-
N
E
T
W
O
R
K
R
E
N
O
V
A
T
I
O
N
77
8
H
I
G
U
E
R
A
S
T
.
S
A
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
1 PLAN CHECK 1 03/02/26
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
J. LONG
J. MEADOWS
J. MEADOWS
E
R
P
R
No. 6488
S
T UC T U R A L
S
TAT
OF C A L I F O R NIA
EGISTERE D R O F E SS IONALEN
G
I
N
E
E
RJESSICAM.MEA
D
O
W
S
PRELIMI
N
A
R
Y
NOT FOR
C
O
N
S
T
R
U
C
T
I
O
N
2 PLAN CHECK 2 04/09/26
1 SLOMA DECK FRAMING PLAN
SCALE: 1/4" = 1'-0"
NORTH
SL
O
M
A
D
E
C
K
F
R
A
M
I
N
G
P
L
A
N
A.SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AND ELEVATIONS INCLUDING, BUT NOT
LIMITED TO THE FOLLOWING, ALL DIMENSIONS TO BE VERIFIED PRIOR TO CONSTRUCTION:
I.ALL DIMENSIONS, ELEVATIONS, FINISH SURFACE, SLOPES, DRAINS, SLAB DEPRESSIONS, ETC
B.REFER TO THE FOLLOWING SHEETS FOR TYPICAL DETAILS:
C.SEE LANDSCAPE ARCHITECTURAL & CIVIL DRAWINGS FOR ALL TOP OF DECKING ELEVATIONS.
D.SEE LANDSCAPE ARCHITECTURAL DRAWINGS FOR DECKING MATERIAL.
DESCRIPTION SHEET (S)
SYMBOLS AND ABBREVIATIONS S-101
STRUCTURAL GENERAL NOTES S-102 - S-103
TESTING AND INSPECTION S-104
TYPICAL CONCRETE DETAILS S-301
TYPICAL MASONRY DETAILS S-401
TYPICAL STEEL DETAILS S-501
TYPICAL WOOD DETAILS S-601 - S-602
DECK FRAMING NOTES
DECK FRAMING SCHEDULES
DECK BEAM SCHEDULE
MARK SIZE REMARKS
B1 6x14 PTDF DROPPED W/ HWPH614 @
HANGING CONDITIONS
B2 3x12 PTDF HU310 @ HANGING
CONDITIONS
B3 4x12 PTDF
HUCQ410-SDS @
HANGING CONDITIONS,
FILL ALL HOLES W/
14" x 2 12" SS SDS SCREWS
DECK JOIST SCHEDULE
MARK SIZE REMARKS
J1 2x12 PTDF @ 16" OC
J2 3x12 PTDF @ 12" OC
SS LUS210-2 @ HANGING
CONDITIONS, FILL ALL
HOLES W/ 0.162" x 3 12"
SCNR RING-SHANK NAILS
PIER SCHEDULE
PIER #DESIGN AXIAL
FORCE -
SERVICE LEVEL
PILE MODEL A.B.
CHANCE
(ICC ESR-2794)
TRANSITION
COUPLER MODEL
A.B. CHANCE
(N) CONST
PILE CAP MODEL
A.B. CHANCE
DETAIL
REFERENCE
LEAD EXTENSION
DP11 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
DP12 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
DP13 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
DP14 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
DP15 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
DP16 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
DP17 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
DP18 11,000 LBS SS175 RS3500 C1500937 C1501357 35/S-243
TP1 5,000 LBS SS175 SS175 N/A C1500459 25/S-243
TP2 5,000 LBS SS175 SS175 N/A C1500459 25/S-243
TP3 5,000 LBS SS175 SS175 N/A C1500459 25/S-243
TP4 5,000 LBS SS175 SS175 N/A C1500459 25/S-243
SYMBOL LEGEND
INDICATES (N) HELICAL PIER
INDICATES (N) HELICAL TIEBACK PIER
S-242 1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
22
FO
R
R
E
F
E
R
E
N
C
E
O
N
L
Y
03/30/2026
DECK LEDGER OVER (E) STONE WALL
2803-07-PS25 -S243 - 55 NTS
DECK JST &
HGR PER PLAN
TREX DECKING (OR SIMILAR)
W/ CONN PER MFR
5 8" Ø SS ATR W/
SET-3G EPOXY
T&B @ 12" OC
CONC CURB PER
LANDSCAPE ARCH
LEDGER PER PLAN
FINISH GRADE
(E) STONE WALL
PAVING PER
LANDSCAPE ARCH
GA
P
P
E
R
LA
N
D
S
C
A
P
E
AR
C
H
14" x 2" SQ SS
PLATE WASHER,
TYP EA ATR
5" MIN
EMBED
21
2"
21
2"
M
I
N
6"
M
I
N
NOTE:
LEDGER SHALL HAVE CURB ANCHORS
WITHIN 6"-12" OF EACH END WHERE
SPLICES OCCUR (UNO ON PLAN)
STRING LIGHT POST CONNECTION
2803-07-PS25 -S243 - 32 NTS
A SECTION W/ JOISTS PARALLEL TO DECK EDGE
7"
MI
N
2"
2"
PT RIM BOARD PER PLAN
5 8"Ø THR ROD, TYP
HDUE3-SDS3 TIE
10
'
-
6
"
M
A
X
HDUE3-SDS3 TIE
7"
MI
N
2"
2"
10
'
-
6
"
M
A
X
STRING LIGHT 'POST'
WO IN LIEU OF TYPICAL
GUARD RAIL 'POST'
B SECTION W/ JOISTS PERPENDICULAR TO DECK EDGE
4x PT JOIST PER PLAN
PROVIDE PLATE WASHER & DOUBLE
NUT @ INT FACE OF RIM, TYP
PT RIM BOARD PER PLAN
5 8"Ø THR ROD, TYP
3 BAYS MIN OF 4x PT BLKG, DEPTH TO MATCH TYP JST
PROVIDE PLATE WASHER & DOUBLE
NUT @ INT FACE OF RIM, TYP
STRING LIGHT 'POST'
WO IN LIEU OF TYPICAL
GUARD RAIL 'POST'
PARTIAL DECK PLAN VIEW AT SKEWED DECK EDGE
SEE DETAIL
FOR DECK INFO
NOT SHOWN
13
-
SEE DETAIL
FOR GUARD RAIL
INFO NOT SHOWN
12
-TYP GUARD RAIL 'POST'
PT RIM BOARD PER PLAN
STRING LIGHT 'POST' PER
SECTION A
14" BENT PL WEDGE EA ANCH
TO FACE OF GUARD RAIL PLATE
14" BENT PL WEDGE EA
ANCH @ INT FACE OF RIM
14
TYP OF 2 EDGES,
EA BENT PL WEDGE
3'
-
6
"
M
A
X
14" STIFFENER
PLATES @ 3'-6" OC
FULL HEIGHT
14" STIFFENER
PLATES @ 3'-6" OC
FULL HEIGHT
3'
-
6
"
M
A
X
3'
-
6
"
M
A
X
3'
-
6
"
M
A
X
3'
-
6
"
M
A
X
3'
-
6
"
M
A
X
NOTE:
CONTRACTOR TO SUBMIT PROPOSED
LIGHT ATTACHMENT TO STEEL COLUMN
TO SEOR PRIOR TO STEEL FABRICATION
HELICAL TIEBACK PIER AT DECK JOIST
2803-07-PS25 -S243 - 35 NTS
3x (MIN) DECK JST
TREX DECKING (OR SIMILAR)
W/ CONN PER MFR
FINISH GRADE
HELICAL PIER HELIXES, DIA &
NUMBER TO BE SELECTED
AFTER TEST PIER IS INSTALLED,
CONTRACTOR TO CONTACT
PROJECT ENGINEER.
NEW CONSTRUCTION PILE
CAP, PER PLAN & MFR
HELICAL TIEBACK PIER, WO, PER
PLAN & MFR (ICC ESR-2794)
6" WIDE SHAPED 14" PL
EA SIDE OF JST W/
(4) 3 4" Ø BOLTS
14
TYP
EA PL
3"3"
3"
3"
MI
N
112"
3"
MI
N
DECK AT (E) TREE
3838-01-HS25 - S601 - 12 1" = 1'-0"
DECK JST PER
PLAN
'A34' EA JST
& EA BLK
2x BLKG W/
'A34' EA BLK
TREX DECKING (OR SIMILAR)
W/ CONN PER MFR
(E) TREE, SEE LANDSCAPE
ARCH DWGS
BM PER PLAN
DECK BM PER PLAN,
SPLICE NOT PERMITTED
@ END CONDITION
DECK POST,
WO, PER PLAN
2'-0" MAX CANTILEVER
'CCQ/ECCQ' POST CAP
GAP PER
LANDSCAPE DRAWINGS
BEAM AT HELICAL PIER W/ DECK EDGE OVER (E) STONE WALL
2803-07-PS25 -S243 - 35 NTS
4'-0" MAX
CANTILEVER
DECK JST PER
PLAN
CONT 2x BLKG
TREX DECKING (OR SIMILAR)
W/ CONN PER MFR
2x RIM JST
DECK BM PER PLAN
CONC CURB PER
LANDSCAPE ARCH
'A35' EA JOIST,
EA SIDE
'A34' EA JST
& EA BLK
FINISH GRADE
(E) STONE WALL
PAVING PER
LANDSCAPE ARCHGAP PER
LANDSCAPE ARCH
GA
P
P
E
R
LA
N
D
S
C
A
P
E
AR
C
H
HELICAL PIER HELIXES,
DIA & NUMBER TO BE
SELECTED AFTER TEST
PIER IS INSTALLED,
CONTRACTOR TO
CONTACT PROJECT
ENGINEER.
HELICAL PIER, WO, PER PLAN
& MFR (ICC ESR-2794)
4"
M
I
N
,
18
"
M
A
X
'CCQO/ECCQO'
POST CAP
NEW CONSTRUCTION PILE
CAP, PER PLAN & MFR
HELICAL TIEBACK PIER, WO, PER
PLAN & MFR (ICC ESR-2794)
DECK EDGE
3838-01-HS25 - S601 - 12 1" = 1'-0"
DECK JST PER
PLAN
'A34' EA JST
& EA BLK
2x BLKG W/
'A34' EA BLK
TREX DECKING (OR SIMILAR)
W/ CONN PER MFR
BM PER PLAN
DECK BM PER PLAN,
SPLICE NOT PERMITTED
@ END CONDITION
DECK POST,
WO, PER PLAN
1'-0" MAX
CANTILEVER
'CCQ/ECCQ' POST CAP
GUARDRAIL PER DETAIL 12/-
DECK JST PER
PLAN
CONT 2x BLKG
TREX DECKING (OR SIMILAR)
W/ CONN PER MFR
2x RIM JST
DECK BM PER PLAN,
SPLICE NOT PERMITTED
@ END CONDITION
DECK POST,
WO, PER PLAN
1'-0" MAX
CANTILEVER
'CCQ/ECCQ' POST CAP
GUARDRAIL PER DETAIL 12/-
DECK JOISTS PERPENDICULAR TO EDGE
'A35' EA JOIST,
EA SIDE
'A34' EA JST
& EA BLK
DECK JOISTS PARALLEL TO EDGE
POST AT HELICAL PIER
2803-07-PS25 -S243 - 14 NTS
NEW CONSTRUCTION PILE
CAP, PER PLAN & MFR
HELICAL PIER HELIXES,
DIA & NUMBER TO BE
SELECTED AFTER TEST
PIER IS INSTALLED,
CONTRACTOR TO
CONTACT PROJECT
ENGINEER.
HELICAL PIER, WO, PER PLAN
& MFR (ICC ESR-2794)
DECK JST PER PLAN
DECKING PER
ARCH
PROVIDE L3x3x14 DIAG
BRC EA POST W/
(3) SDS 1 4"Ø x 1 3 4"
SCREWS EA END
DECK BM PER PLAN,
SPLICE NOT PERMITTED
@ END CONDITION
'CCQ/ECCQ' POST CAP
CRIPPLE POST PER PLAN
'CCQO/ECCQO'
POST CAP
4"
M
I
N
,
18
"
M
A
X
'A34' EA JST
& EA BLK
2x BLKG W/
'A34' EA BLK
℄ BRC
EQ
EQ
4
5
°
INVERTED 'PCZ' POST CAP
GUARD RAIL CONNECTION
2803-07-PS25 -S243 - 12 NTS
'DTT2Z' DECK TENSION TIE
W/ (8) SDS 14" x 1 12" EVERY
OTHER 'POST'
(EA 'SECTION' SHALL HAVE
TIE AT FIRST & LAST 'POST')
GUARD RAIL 'POST'
A BCONNECTION TO RIM BOARD & BLKG CONNECTION TO RIM & DECK JOIST
PARTIAL DECK PLAN VIEW
GUARD RAIL 'POST'
2x PT BLKG TO
MATCH JOIST
DEPTH
GUARD
RAIL 'POST'
7"
MI
N
2"
2"
PT RIM BOARD PER PLAN
(2) 12"Ø BOLTS EA 'POST'
PT JOIST PER PLAN
PT RIM BOARD PER PLAN
JOIST PER PLAN
PT RIM JOIST
PER PLAN
42
"
M
A
X
B
A
C INTERIOR ELEVATION OF RIM JOIST
C
'DTT2Z' DECK TENSION TIE
W/ (8) SDS 14" x 1 12" EVERY
OTHER 'POST'
(EA 'SECTION' SHALL HAVE
TIE AT FIRST & LAST 'POST')
7"
MI
N
2"
2"
42
"
M
A
X
GUARD RAIL 'POST'
PT RIM BOARD PER PLAN
(2) 12"Ø BOLTS EA 'POST'
PT JOIST PER PLAN
GUARD RAIL
'POST'
GUARDRAIL 'SECTION'
PT RIM BOARD PER PLAN
(2) 12"Ø BOLTS EA 'POST'
PT JOIST PER PLAN
'DTT2Z' DECK TENSION TIE
W/ (8) SDS 1 4" x 1 12" EVERY
OTHER 'POST'
(EA 'SECTION' SHALL HAVE
TIE AT FIRST & LAST 'POST')
'A35' EA JOIST, EA SIDE
7 'POSTS' MAX AT STRAIGHT 'SECTION'
6 'POSTS' MAX AT CORNER 'SECTION'
SEE DETAIL
FOR INFO
NOT SHOWN
13
-
1262
334353
15253555
63 13
61
S-243
DE
C
K
D
E
T
A
I
L
S
N:
\
2
8
0
0
\
2
8
0
3
-
0
7
-
P
S
2
5
-
S
L
O
M
A
-
T
I
-
C
D
s
\
S
t
r
u
c
t
u
r
a
l
\
C
o
n
D
o
c
s
\
S
h
e
e
t
-
F
i
l
e
s
\
2
8
0
3
-
0
7
-
P
S
2
5
-
S
2
4
3
.
d
w
g
,
S
2
4
3
,
M
a
r
3
0
,
2
0
2
6
1
1
:
3
7
a
m
,
j
d
l
o
n
g
CONSULTANT
RRM DESIGN GROUP COPYRIGHT 2026.
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE
WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE
RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW
SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
rrmdesign.com | (805) 543-1794
AGENCY
PROJECT MANAGER
DRAWN BY
PROJECT NUMBER
CHECKED BY
SHEET
12/17/2025
2803-07-PS25
DATE
NO.REVISION DATE
SL
O
M
A
-
N
E
T
W
O
R
K
R
E
N
O
V
A
T
I
O
N
77
8
H
I
G
U
E
R
A
S
T
.
S
A
N
L
U
I
S
O
B
I
S
P
O
,
C
A
9
3
4
0
1
1 PLAN CHECK 1 03/02/26
TH
I
R
D
S
U
B
M
I
T
T
A
L
F
O
R
P
E
R
M
I
T
T
I
N
G
J. LONG
J. MEADOWS
J. MEADOWS
E
R
P
R
No. 6488
S
T UC T U R A LS
TAT
OF C A L I F O R NIA
EGISTERE D R O F E SSIONAL
EN
G
I
N
E
E
RJESSICAM.ME
A
D
O
W
S
PRELIMI
N
A
R
Y
NOT FOR
C
O
N
S
T
R
U
C
T
I
O
N
2 PLAN CHECK 2 04/09/26
32
11
1
1
2
2
FO
R
R
E
F
E
R
E
N
C
E
O
N
L
Y
03/30/2026