Loading...
HomeMy WebLinkAboutFire_Station_No._1_3_31_2026_10_26_57_AM_ea1c6472-223a-4555-b3cb-ec4381745321_ExcelName Record Number 397494 397496 397499 397498 397478 397459 397532 397529 397531 397534 397533 397535 397538 397501 397487 397480 397463 397461 397519 397521 397483 397484 397515 397504 397503 397493 397481 397482 397495 397497 397479 397525 397466 397485 397490 397530 397536 397502 397488 397526 397489 397486 397527 397477 397454 489961 397453 397507 397509 397510 397511 397512 397513 397505 397506 397462 397469 397472 397473 397474 397475 397467 397468 397522 397524 397517 397518 397520 397523 397492 397457 397465 397464 397528 397458 397456 Picture 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Fire Station No. 1 - 2160 Santa Barbara Avenue San Luis Obispo, CA 93401 Category Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Signage Restrooms Restrooms Break/Conference Room Break/Conference Room Parking Parking Path of Travel Path of Travel Path of Travel Path of Travel Ramps Ramps Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Doors Counters Signage Signage Signage Signage Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Restrooms Break/Conference Room Break/Conference Room Break/Conference Room Break/Conference Room Break/Conference Room Break/Conference Room Break/Conference Room Picnic Areas Reach Ranges Reach Ranges Signage Signage Signage Location Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Museum Museum Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Exterior Exterior Exterior Exterior Exterior Exterior Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Exterior Exterior Museum Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Fire Station Exterior Exterior Exterior Fire Station Fire Station Fire Station Sub Location Description Apparatus Bay - Exterior Apparatus Bay - Interior Apparatus Bay - Interior Apparatus Bay - Interior Battalion Chief Office Doorway Across From Administrative Analyst Office Main Entrance Main Entrance Main Entrance Museum Main Entrance Museum Main Entrance Training Room - Exterior Training Room - Exterior Training Room - Interior Womens Restroom Main Entrance Womens Restroom Womens Restroom Break Room Break Room Parking Lot Parking Lot Sidewalk From The Accessible Space Sidewalk From The Public Right Of Way Sidewalk From The Public Right Of Way Sidewalk To Museum Ramp Next To Apparatus Bay Ramp Next To Apparatus Bay Apparatus Bay - Exterior Apparatus Bay - Interior Battalion Chief Office Captains Office Fire Inspector 3 Office Fire Inspectors Office Fire Marshals Office Main Entrance Training Room - Exterior Training Room - Interior Womens Restroom Front Counter Apparatus Bay - Exterior Call Box Next To Main Entrance, Emergency Call Station Next To Main Entrance Directional Signage From The Public Right Of Way Museum Main Entrance Mens Restroom Mens Restroom Mens Restroom Mens Restroom Mens Restroom Mens Restroom Mens Restroom Mens Restroom Mens Restroom Mens Restroom Mens Restroom Womens Restroom Womens Restroom Womens Restroom Womens Restroom Womens Restroom Womens Restroom Womens Restroom Womens Restroom Break Room Break Room Break Room Break Room Break Room Break Room Training Room Picnic Table Next To Training Room Exterior Exterior Administrative Analyst Office, Hazardous Materials Coordinators Office, Fire Marshals Office, Fire Inspector 3 Office, Training Room - Interior, Training Room - Exterior Battalion Chief Office, Apparatus Bay - Interior Fire Inspectors Office, Fire Chief Office, Deputy Chief Office, Doorway Across From Administrative Analyst Office, Captains Office Sub Description Lever Lever Pull Side Push Side Lever Push / Pull Pull Side Push Bar / D Handle Push Side Pull Side Push Side Lever Pull Side Lever Lever Lavatory Soap Sink Sink Accessible Space Warning Sign Vehicular Traffic Change In Level Exterior Walkway Exterior Walkway Run 1 Run 1 Left Handrail Lever Pull Side Pull Side Pull Side Pull Side Pull Side Push Side Push Bar / D Handle Lever Pull Side Pull Side Lavatory Lavatory Soap Lavatory Microwave - Appliance Paper Towel Sink Sink Sink Soap Table Call Box Next To Main Entrance - Other Emergency Call Station Next To Main Entrance - Emergency Call Station Item Door Opening Pressure Door Opening Pressure Floor Mat Floor Mat Door Hardware Door Opening Pressure Floor Mat Door Opening Pressure Floor Mat Floor Mat Floor Mat Door Opening Pressure Floor Mat Door Opening Pressure Door Opening Pressure Accessible Element/Entrance Signage Lavatory - Supply Lines Wrapping Dispenser Height Pipes Wrapping Supply Lines Van Accessible Signage Parking Lot Warning Sign Wording Incorrect Detectable Warnings Change in Level Walking Surface Cross Slope Walking Surface Cross Slope Handrail Handrail Extension Length Door Lock Front Approach Latch Side Clearance Front Approach Latch Side Clearance Front Approach Latch Side Clearance Front Approach Clear Floor Space Length Front Approach Clear Floor Space Length Front Approach Clear Floor Space Length Door Lock Door Lock Front Approach Clear Floor Space Length Front Approach Clear Floor Space Length Counter Height Room Identification Information Signage Directional or Information Signage Accessible Element/Entrance Signage Lavatory - Supply Lines Wrapping Lavatory Pipes Wrapping Dispenser Height Toilet Distance From Wall Distance from Back Wall to Front of Grab Bar Distance from Front Edge of Toilet to Front of Grab Bar Rear Grab Bar Interferes Rear Grab Bar Location Coat Hook Height Seat Cover Dispenser Height Seat Cover Dispenser Lavatory Knee Clearance Toilet Distance From Wall Distance from Back Wall to Front of Grab Bar Distance from Front Edge of Toilet to Front of Grab Bar Rear Grab Bar Interferes Coat Hook Height Seat Cover Dispenser Height Seat Cover Dispenser Reach Height Break Room Sink - Counter Height Toe Kick Clear Floor Space Length Break Room Tables - Knee Clearance Minimum 5% Accessible Element Highest Point of Operation Operable with one hand Room Identification Room Identification Room Identification Finding The door opening force for this door is greater than allowed. The door opening force for this door is greater than allowed. An unstable floor mat is provided at the door landing. An unstable floor mat is provided at the door landing. Has a door stop. The door opening force for this door is greater than allowed. An unstable floor mat is provided at the door landing. The door opening force for this door is greater than allowed. An unstable floor mat is provided at the door landing. An unstable floor mat is provided at the door landing. An unstable floor mat is provided at the door landing. The door opening force for this door is greater than allowed. An unstable floor mat is provided at the door landing. The door opening force for this door is greater than allowed. The door opening force for this door is greater than allowed. There is no room signage. The supply lines under the lavatory do not provide protection against contact. The height of the controls and operating mechanisms for the dispenser is not at the correct height. The pipes are not wrapped for the sink. Supply lines are not wrapped for the break/conference room sink. There is no additional signage marked "van accessible" at the van accessible parking space. The warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot does not have the correct wording. The pedestrian route adjoins vehicular traffic. There is a change in elevation greater than recommended value. There are cross slopes greater than allowed on the primary path of travel. There are cross slopes greater than allowed on the primary path of travel. There is only one handrail provided. There is not enough handrail extension beyond the top or bottom of the rail. The door lock requires tight grasping, pinching, or twisting of the wrist to operate. There is less than the required latch side clearance on the pull side of the door. There is less than the required latch side clearance on the pull side of the door. There is less than the required latch side clearance on the pull side of the door. There is not enough clear floor space provided at the pull side of the door. There is not enough clear floor space provided at the pull side of the door. There is not enough clear floor space provided at the push side of the door . The door lock requires tight grasping, pinching, or twisting of the wrist to operate. The door lock requires tight grasping, pinching, or twisting of the wrist to operate. There is not enough clear floor space provided at the pull side of the door. There is not enough clear floor space provided at the pull side of the door. The height of the counter or desk does not comply with height requirements. There is no compliant room identification signage provided. There is no informational signage. There is no directional signage. There is no room signage. The supply lines under the lavatory do not provide protection against contact. The pipes under the lavatory do not provide protection against contact. The height of the controls and operating mechanisms for the dispenser is not at the correct height. The distance from the center of the toilet to the nearest side wall does not meet the required distance. The distance from the back wall to the front of the grab bar is less than required. The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Rear grab bar interferes with the tank/flushometer. Rear grab bar location is not compliant. The coat hook is not mounted at the correct height. The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Seat cover dispenser interferes with use of grab bar. The knee clearance space under the lavatory is less than the required minimum height. The distance from the center of the toilet to the nearest side wall does not meet the required distance. The distance from the back wall to the front of the grab bar is less than required. The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Rear grab bar interferes with the tank/flushometer. The coat hook is not mounted at the correct height. The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Seat cover dispenser interferes with use of grab bar. Appliance Reach Height in the break/conference room is not compliant. The height of the controls and operating mechanisms for the dispenser is not at the correct height. Sink counter height does not meet the standards. The toe kick for the sink in break/conference room is not removed. There is not enough clear floor space at the sink. The height of the controls and operating mechanisms for the dispenser is not at the correct height. The table knee clearance does not meet required standards. The required percentage of picnic tables provided are not accessible. The highest point of operation for the element is not compliant. Element controls are non accessible. There is no compliant room identification signage provided. There is no compliant room identification signage provided. There is no compliant room identification signage provided. On Site Finding 8.00 pounds 8.00 pounds Not Compliant Not Compliant Found 8.00 pounds Not Compliant 9.00 pounds Not Compliant Not Compliant Not Compliant 8.00 pounds Not Compliant 9.00 pounds 6.00 pounds None Found Not Wrapped 51.25 inches Not Wrapped Not Wrapped None Found Incorrect Wording None Found 0.50 inches 4.60 percent for 20.00 feet 3.10 percent for 20.00 feet Missing Handrail 9.75 inches Not Accessible 17.00 inches 7.50 inches 17.50 inches 48.75 inches 49.00 inches 30.50 inches Not Accessible Not Accessible 42.00 inches 38.50 inches 41.75 inches None Found Not Found None Found None Found Not Wrapped Pipes not wrapped. 51.00 inches 19.75 inches on center 53.50 inches 22.25 inches Not Compliant Not Compliant 76.50 inches 40.50 inches Interferes 26.50 inches 18.75 inches on center 53.50 inches 23.50 inches Not Compliant 56.75 inches 41.25 inches Interferes 50.00 inches 45.50 inches 35.50 inches Not Removed 44.00 inches 51.50 inches 26.25 inches None Found 55.00 inches None Found None Found None Found None Found Recommendation Adjust the closer on the door to meet the door opening force requirements. Adjust the closer on the door to meet the door opening force requirements. Provide a compliant floor mat for the door. Provide a compliant floor mat for the door. Remove the door stop. Adjust the closer on the door to meet the door opening force requirements. Provide a compliant floor mat for the door. Adjust the closer on the door to meet the door opening force requirements. Provide a compliant floor mat for the door. Provide a compliant floor mat for the door. Provide a compliant floor mat for the door. Adjust the closer on the door to meet the door opening force requirements. Provide a compliant floor mat for the door. Adjust the closer on the door to meet the door opening force requirements. Adjust the closer on the door to meet the door opening force requirements. Install accessible room signage. Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. Relocate the dispenser to the correct height. Insulate or otherwise configure the water supply and drain pipes under the sink to protect against contact. Make certain there are no sharp or abrasive surfaces under the sink. Make sure that the supply lines are fully wrapped and insulated for the sink. Van accessible parking spaces shall provide additional signage that states "van accessible" . Provide compliant signage regarding unauthorized use of accessible parking spaces. Provide detectable warnings. Ensure that the change in elevation is within the recommended value. Provide a compliant path of travel. Provide a compliant path of travel. Provide a compliant handrail with a compliant distance between the handrail and the adjacent wall. Provide compliant handrail extensions that are parallel to the floor or ground surface extending the required distance beyond the bottom of the ramp and return smoothly to the post or wall. Provide a compliant door lock for the door that does not require tight grasping, pinching, or twisting of the wrist to operate. Provide required latch side clearance on the pull side of the door. Provide required latch side clearance on the pull side of the door. Provide required latch side clearance on the pull side of the door. Provide the recommended clear floor space on the pull side of the door. Provide the recommended clear floor space on the pull side of the door. Provide the recommended clear floor space on the push side of the door. Provide a compliant door lock for the door that does not require tight grasping, pinching, or twisting of the wrist to operate. Provide a compliant door lock for the door that does not require tight grasping, pinching, or twisting of the wrist to operate. Provide the recommended clear floor space on the pull side of the door. Provide the recommended clear floor space on the pull side of the door. Provide a portion of counter at the compliant height. Install compliant room identification signage. Install informational signage to each accessible element or room or location. Install directional signage to each accessible element or room. Install accessible room signage. Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. Relocate the dispenser to the correct height. Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. Install or move the grab bar to create the required distance from the back wall to the front of the grab bar. Install or relocate the side grab bar so that the distance from the front edge of the toilet to the front edge of the side grab bar meets the required minimum distance. Readjust the rear grab bar so that it does not interfere with the tank/flushometer. Remount the rear grab bar to a compliant location. Mount the coat hook at the recommended height. Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Move the seat cover dispenser so it does not interfere with the use of the grab bars. Raise or replace the lavatory to provide the minimum required knee clearance. Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. Install or move the grab bar to create the required distance from the back wall to the front of the grab bar. Install or relocate the side grab bar so that the distance from the front edge of the toilet to the front edge of the side grab bar meets the required minimum distance. Readjust the rear grab bar so that it does not interfere with the tank/flushometer. Mount the coat hook at the recommended height. Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Move the seat cover dispenser so it does not interfere with the use of the grab bars. Make sure that the specified appliance reach height is compliant. Relocate the dispenser to the correct height. Provide compliant sink. Remove the toe kick for the sink. Provide enough clear floor space at the location. Relocate the dispenser to the correct height. Provide compliant tables. Provide a sufficient number of compliant picnic tables. Make sure that the highest point of operation is within the recommended value. Provide compliant controls for the element. Install compliant room identification signage. Install compliant room identification signage. Install compliant room identification signage. Recommended Value Up to 5.00 pounds Up to 5.00 pounds See Recommendation See Recommendation See Recommendation Up to 5.00 pounds See Recommendation Up to 5.00 pounds See Recommendation See Recommendation See Recommendation Up to 5.00 pounds See Recommendation Up to 5.00 pounds Up to 5.00 pounds See Recommendation See Recommendation Up to 40.00 inches See Recommendation See Recommendation See Recommendation See Recommendation See Recommendation Up to 0.25 inches Up to 2.08 percent Up to 2.08 percent See Recommendation At least 12.00 inches See Recommendation At least 18.00 inches At least 18.00 inches At least 18.00 inches At least 60.00 inches At least 60.00 inches At least 48.00 inches See Recommendation See Recommendation At least 60.00 inches At least 60.00 inches 28.00 - 34.00 inches See Recommendation See Recommendation See Recommendation See Recommendation See Recommendation See Recommendation Up to 40.00 inches 17.00 - 18.00 inches At least 54.00 inches At least 24.00 inches See Recommendation See Recommendation 15.00 - 48.00 inches Up to 40.00 inches See Recommendation At least 27.00 inches 17.00 - 18.00 inches At least 54.00 inches At least 24.00 inches See Recommendation 15.00 - 48.00 inches Up to 40.00 inches See Recommendation Up to 48.00 inches Up to 40.00 inches Up to 34.00 inches See Recommendation At least 48.00 inches Up to 40.00 inches At least 27.00 inches At least 1.00 tables 15.00 - 48.00 inches See Recommendation See Recommendation See Recommendation See Recommendation Deviation 3.00 3.00 3.00 4.00 3.00 4.00 1.00 11.25 0.25 2.52 1.02 -2.25 -1.00 -10.50 -0.50 -11.25 -11.00 -17.50 -18.00 -21.50 7.75 11.00 1.75 -0.50 -1.75 28.50 0.50 -0.50 0.75 -0.50 -0.50 8.75 1.25 2.00 5.50 1.50 -4.00 11.50 -0.75 -1.00 7.00 Measure Units pounds pounds pounds pounds pounds pounds pounds inches inches percent percent inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches tables inches Costing Info Adjust door closer pressure Adjust door closer pressure Install mat that grips to the floor surface Install mat that grips to the floor surface Remove door stop Adjust door closer pressure Install mat that grips to the floor surface Adjust door closer pressure Install mat that grips to the floor surface Install mat that grips to the floor surface Install mat that grips to the floor surface Adjust door closer pressure Install mat that grips to the floor surface Adjust door closer pressure Adjust door closer pressure Install signage Wrap supply lines Provide compliant dispenser Wrap pipes Wrap pipes Install post mounted sign Install signage Install detectable warnings Provide smooth surface Install pathway Install pathway Provide compliant handrail with extensions Provide compliant handrail extensions Provide door lock Install automatic door opener Install automatic door opener Install automatic door opener Install automatic door opener Install automatic door opener Install automatic door opener Provide door lock Provide door lock Install automatic door opener Install automatic door opener Provide compliant counter Install signage Install signage Install signage Install signage Wrap supply lines Wrap pipes Provide compliant dispenser Relocate fixture Provide compliant grab bar Provide compliant grab bar Provide compliant grab bars Provide a compliant back grab bar. Move coat hook Provide compliant dispenser Provide compliant lavatory Relocate fixture Provide compliant grab bar Provide compliant grab bar Provide compliant grab bars Move coat hook Provide compliant dispenser Adjust appliance height Relocate dispenser Provide compliant sink Unknown scope Relocate dispenser Adjust/Replace Table Accessible table (each) Readjust element height Install signage Install signage Install signage Blank or Unassigned cost estimate cells indicate further design requirements or modification by original vendor. Estimated Cost 25 25 126 126 50 25 126 25 126 126 126 25 126 25 25 158 149 277 149 149 250 300 144 150 3600 3600 2200 2400 310 4000 4000 4000 2921 2921 4000 310 310 2921 2921 3500 158 316 158 158 149 149 277 2500 267 267 231 267 50 277 277 1286 2500 267 267 231 50 277 277 1200 110 1800 612 900 110 500 500 50 500 948 316 790 65739 Notes Notes : ISA is present. Notes : Supply lines not completely wrapped. Notes : Cabinet obstructs clear floor space length. Notes : Cabinet obstructs clear floor space length. Notes : Signage contains the word Handicapped. Notes : Cabinet obstructs latch side clearance. Notes : Desk obstructs clear floor space length. Notes : Desk obstructs clear floor space length. Notes : Sofa obstructs clear floor space length. Notes : Cabinet obstructs clear floor space length. Notes : ISA is present. Notes : Supply lines not completely wrapped. Notes : Supply lines not completely wrapped. Notes : Supply lines not completely wrapped. Notes : Cabinet obstructs clear floor space length. Notes : Cabinet obstructs clear floor space length. Notes : Cabinet obstructs clear floor space length. Code Reference ADA 404.2, CA 11B-404.2 ADA 404.2, CA 11B-404.2 ADA 403.2, 302.1, CA 11B-302.1,403.2 ADA 403.2, 302.1, CA 11B-302.1,403.2 ADA 404, 404.2, CA 11B-404.2 ADA 404.2, CA 11B-404.2 ADA 403.2, 302.1, CA 11B-302.1,403.2 ADA 404.2, CA 11B-404.2 ADA 403.2, 302.1, CA 11B-302.1,403.2 ADA 403.2, 302.1, CA 11B-302.1,403.2 ADA 403.2, 302.1, CA 11B-302.1,403.2 ADA 404.2, CA 11B-404.2 ADA 403.2, 302.1, CA 11B-302.1,403.2 ADA 404.2, CA 11B-404.2 ADA 404.2, CA 11B-404.2 ADA 216.2, 216.6, CA 11B-216.2,216.6 ADA 213, 606, 606.5, CA 11B-606.5 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 ADA 606.5, CA 11B-606.5 ADA 606.5, CA 11B-606.5 ADA 502, 502.6 CA 11B- 502 ADA 705, CA 11B-247.1 ADA 303, 403.4, CA 11B-303,403.4 ADA 402, 403.3, CA 11B-403.3 ADA 402, 403.3, CA 11B-403.3 ADA 405, 405.8, 505.2, CA 11B-405.8,505.2 ADA 405, 405.8, 505.10, CA 11B-405.8,505.10 ADA 404.2, 309.4 ADA 404, 404.2, CA 11B-404.2 ADA 404, 404.2, CA 11B-404.2 ADA 404, 404.2, CA 11B-404.2 ADA 404, 404.2, CA 11B-404.2 ADA 404, 404.2, CA 11B-404.2 ADA 404, 404.2, CA 11B-404.2 ADA 404.2, 309.4 ADA 404.2, 309.4 ADA 404, 404.2, CA 11B-404.2 ADA 404, 404.2, CA 11B-404.2 ADA 902, 904, CA 11B-904.4 ADA 703, 216, 216.2, CA 11B-216.2 ADA 216.3, CA 11B-216.3, 703.5,703.5 ADA 703, 216, 216.3, CA 11B-216.3, 703.5,703.5 ADA 216.2, 216.6, CA 11B-216.2,216.6 ADA 213, 606, 606.5, CA 11B-606.5 ADA 213, 606, 606.5, CA 11B-606.5 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 ADA 603, 604.2, CA 11B-604.2 ADA 603, 609, 604.5, CA 11B-604.5,609 CA 11B- 604.5 ADA 609.3, CA 11B-609.3 ADA 604.5, CA 11B-604.5 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 ADA 609.3 ADA 213, 606, 606.2, 306.3, CA 11B-606.2,306.3 ADA 603, 604.2, CA 11B-604.2 ADA 603, 609, 604.5, CA 11B-604.5,609 CA 11B- 604.5 ADA 609.3, CA 11B-609.3 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 ADA 609.3 ADA 309, 205, 308, CA 11B-308,309,205 ADA 309, 308 ADA 606.3, CA 11B-606.3 ADA 305, 306, 606.2, CA 11B-606.2,305,306 ADA 309, 205, 308, 228 ADA 309, 308 ADA 305, 306, 902.2, CA 11B-902.2,305,306 ADA 309, 305, 205, 306, 308, 902, 228, 226.1 ADA 309, 308, CA 11B-308,309 ADA 302, 309, 205, 308, 410, CA 11B-309.4 ADA 703, 216, 216.2, CA 11B-216.2 ADA 703, 216, 216.2, CA 11B-216.2 ADA 703, 216, 216.2, CA 11B-216.2 None Landlord Tenant Both City County District Resident Other Cost Responsibility Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord None Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord Landlord None None None 0 0 0 0 0 0 0 0 0 Priority Three Three Three Three Three Three Three Three Three Three Three Three Three Three Three Three Three Three Three Three Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Six Eight Eight Eight Progress Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Not_Started Resolution Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Not_Set Projected Completion Date 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2035 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2021 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 12/31/2035 Actual Completion Date Actual Cost 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments No Comments Permanent room signage is not required for offices per CDD Building and Safety. GCRUCESLOCITY.ORG. Permanent room signage is not required for offices per CDD Building and Safety. GCRUCESLOCITY.ORG. Permanent room signage is not required for offices per CDD Building and Safety. GCRUCESLOCITY.ORG. Contractor Assignment Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_2 Category_2 Category_1 Category_1 Category_1 Category_1 Category_1 Category_1 Category_2 Category_1 Category_1 Category_1 Category_2 Category_1 Category_2 Category_2 Category_2 Category_2 Category_2 Category_2 Category_1 Category_2 Category_2 Category_2 Category_2 Category_2 Category_2 Category_1 Category_1 Category_2 Category_2 Category_2 Category_2 Category_2 Category_2 Category_1 Category_2 Category_1 Category_1 Category_1 Category_2 Category_2 Category_2 Category_1 Category_1 Category_1 Category_1 Category_1 New Value 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Latitude Longitude Designated Staff FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC FAC ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG ENG Fire Station No. 1 Main Picture