HomeMy WebLinkAboutPolice_Station_3_31_2026_10_32_39_AM_34aafa32-25fc-4fbd-9c91-daa034835479_ExcelName Police Station - 1042 Walnut Street San Luis Obispo, CA 93442 Blank or Unassigned cost estimate cells indicate further design requirements or modification by original vendor. Record Number Picture Category Location Sub Location Description Sub Description Item Finding On Site Finding Recommendation Recommended Value Deviation Measure Units Costing Info Estimated Cost Notes Code Reference Cost Responsibility Priority Progress Resolution Projected Completion Date Actual Completion Date Actual Cost Comments Contractor Assignment New Value Latitude Longitude Designated Staff 446379 0 Stairs 1st Floor Stairs to Workout Room Run 1 Riser Striping There is no detectable striping on the stairways. None Found Affix compliant contrasting striping to the upper approach and each tread that is the correct width and distance from the nosing. See Recommendation Add non-slip surface to stair tread 1000 ADA 504, CA 11B-504.4 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445425 0 Doors 2nd Floor Conference Room Next to Interview Room Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445396 0 Doors 1st Floor Crime Lab Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445247 0 Doors 1st Floor Crime Lab Office Single Knob Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446526 0 Doors 1st Floor Doorway Across from Interview Room 1 in Lobby Lever Door Opening Pressure The door opening force for this door is greater than allowed. 10.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 5.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446527 0 Doors 1st Floor Doorway Across from Interview Room 1 in Lobby Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446390 0 Doors 1st Floor Doorway Next to Administrative Assistant Lever Door Opening Pressure The door opening force for this door is greater than allowed. 10.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 5.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445296 0 Doors 2nd Floor Investigations Lieutenant Single Knob Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445235 0 Doors 1st Floor Lecture Room Single Knob Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445475 0 Doors 1st Floor Locker Room Entrance - Interior Push / Pull Door Opening Pressure The door opening force for this door is greater than allowed. 6.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 1.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446531 0 Doors 2nd Floor Main Entrance Pull Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446529 0 Doors 2nd Floor Main Entrance Push Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445385 0 Doors 1st Floor Mens Restroom Next to Locker Room Push / Pull Door Opening Pressure The door opening force for this door is greater than allowed. 6.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 1.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445328 0 Doors 2nd Floor Mens Restroom Next to Records Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445329 0 Doors 2nd Floor Mens Restroom Next to Records Single Knob Door Opening Pressure The door opening force for this door is greater than allowed. 9.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 4.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445330 0 Doors 2nd Floor Mens Restroom Next to Records Single Knob Door Lock The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Not Accessible Provide a compliant door lock for the door that does not require tight grasping, pinching, or twisting of the wrist to operate. See Recommendation Provide door lock 310 ADA 404.2, 309.4 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446483 0 Doors 1st Floor North Entrance Next to Rain Gear Push Bar / D Handle Door Opening Pressure The door opening force for this door is greater than allowed. 11.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 6.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445492 0 Doors 1st Floor Property Office Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 449007 0 Doors 2nd Floor Records Area Next to Lobby Counter Single Knob Door Opening Pressure The door opening force for this door is greater than allowed. 6.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 1.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445497 0 Doors 2nd Floor Records Supervisor Single Knob Door Opening Pressure The door opening force for this door is greater than allowed. 6.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 1.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445196 0 Doors 1st Floor Report Writing Single Knob Door Opening Pressure The door opening force for this door is greater than allowed. 10.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 5.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446346 0 Doors 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Push Bar / Lever Door Opening Pressure The door opening force for this door is greater than allowed. 12.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 7.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446347 0 Doors 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Push Bar / Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445389 0 Doors 2nd Floor Staff Lounge Push / Pull Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445232 0 Doors 1st Floor Training Room Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_2 0 FAC 445356 0 Doors 1st Floor Training Room - Exterior Lever Door Opening Pressure The door opening force for this door is greater than allowed. 10.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 5.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445357 0 Doors 1st Floor Training Room - Exterior Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445360 0 Doors 1st Floor Training Room - Exterior Push Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 449081 0 Doors 1st Floor West Entrance Next to Special Enforcement Team Lever Door Hardware Has a door stop. Found Remove the door stop. See Recommendation Remove door stop 50 ADA 404, 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 449086 0 Doors 1st Floor West Entrance Next to Special Enforcement Team Pull Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446386 0 Doors 1st Floor Workout Room Exterior Entrance Single Knob Door Opening Pressure The door opening force for this door is greater than allowed. 9.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 4.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446451 0 Signage 1st Floor Workout Room Next to Mens Locker Room Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_2 0 FAC 445413 0 Restrooms 2nd Floor Mens Restroom Next to Records Lavatory Lavatory Pipes Wrapping The pipes under the lavatory do not provide protection against contact. Pipes not wrapped. Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap pipes 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_2 0 FAC 445414 0 Restrooms 2nd Floor Mens Restroom Next to Records Lavatory Lavatory - Supply Lines Wrapping The supply lines under the lavatory do not provide protection against contact. Not Wrapped Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap supply lines 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_2 0 FAC 445453 0 Restrooms 2nd Floor Mens Restroom Next to Records Coat Hook Height The coat hook is not mounted at the correct height. 69.50 inches Mount the coat hook at the recommended height. 15.00 - 48.00 inches 21.50 inches Move coat hook 50 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 449001 0 Restrooms 2nd Floor Unisex Restroom in Lobby Coat Hook Height The coat hook is not mounted at the correct height. 70.00 inches Mount the coat hook at the recommended height. 15.00 - 48.00 inches 22.00 inches Move coat hook 50 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 449063 0 Restrooms 2nd Floor Unisex Restroom in Lobby Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 45.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 5.00 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_2 0 FAC 446476 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Lavatory Lavatory Pipes Wrapping The pipes under the lavatory do not provide protection against contact. Pipes not wrapped. Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap pipes 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445317 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Coat Hook Height The coat hook is not mounted at the correct height. 69.75 inches Mount the coat hook at the recommended height. 15.00 - 48.00 inches 21.75 inches Move coat hook 50 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_2 0 FAC 446361 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Coat Hook Height The coat hook is not mounted at the correct height. 75.50 inches Mount the coat hook at the recommended height. 15.00 - 48.00 inches 27.50 inches Move coat hook 50 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446499 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Door Sign - Female Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446496 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Lavatory Lavatory Pipes Wrapping The pipes under the lavatory do not provide protection against contact. Pipes not wrapped. Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap pipes 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 446497 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Lavatory Lavatory - Supply Lines Wrapping The supply lines under the lavatory do not provide protection against contact. Not Wrapped Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap supply lines 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445210 0 Break/Conference Room 1st Floor Lecture Room Paper Towel Break Room The height of the controls and operating mechanisms for the dispenser is not at the correct height. 47.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 7.00 inches Relocate dispenser 110 ADA 309, 308 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 445255 0 Break/Conference Room 1st Floor Training Room Paper Towel Break Room The height of the controls and operating mechanisms for the dispenser is not at the correct height. 57.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 17.00 inches Relocate dispenser 110 ADA 309, 308 Landlord Three Not_Started Not_Set 44926 0 No Comments Category_1 0 FAC 449069 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Outline is Faded, Damaged or Missing The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Faded or Damaged Re-stripe the existing parking space marked as accessible to define the width of the space. See Recommendation Re-stripe existing parking space 350 ADA 502, 502.2, CA 11B-502.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449070 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Parking Space Slope The slope of the accessible parking space is not compliant. 6.30 percent Repave the accessible space to provide a compliant slope. Up to 2.08 percent 4.22 percent Repave surface to correct slope and re-stripe 3800 ADA 502, 502.4, CA 11B-502.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449071 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Parking Space Length The accessible parking space does not meet the minimum requirement for length. 168.00 inches Re-stripe the accessible parking space. At least 216.00 inches -48.00 inches Re-stripe existing parking space 350 CA 11B- 502.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449072 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Parking Lot Warnings There is no minimum fine sign at the parking space. Not Found Provide a minimum fine sign at the parking space below the International Symbol of Accessibility. See Recommendation Install signage 300 CA 11B- 502.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449073 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Parking Space Accessible Signage Height The height of the wall-mounted signage at the accessible space is not compliant. 43.25 inches Remount the wall-mounted signage at the accessible parking space at a compliant height. At least 60.00 inches -16.75 inches Install signage 158 ADA 502, 502.6, CA 11B-502.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449074 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Access Aisle Width The access aisle does not meet the minimum required width. 28.75 inches Re-stripe the access aisle. At least 96.00 inches -67.25 inches Stripe an access aisle 250 CA 11B- 502.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449076 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Access Aisle Slope The slope of the access aisle is not compliant. 6.70 percent Repave the access aisle to provide a compliant surface slope. Up to 2.08 percent 4.62 percent Repave surface to correct slope and re-stripe 3800 ADA 502, 502.4, CA 11B-502.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449077 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Access Aisle The access aisle at the parking space is not outlined in blue. Not Outlined in blue Outline the access aisle in blue color. See Recommendation 180 CA 11B- 502.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449078 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Access Aisle Striping The hatched lines are striped a noncompliant distance on center. Not on 36" center Re-stripe the hatched lines in a contrasting color at a compliant distance on center. See Recommendation Re-stripe lines 350 CA 11B- 502.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449079 0 Parking Exterior Parking Lot Accessible Space Next to Workout Room Exterior Entrance Access Aisle - "No Parking" The access aisle does not contain the wording "No Parking" painted in white letters within the access aisle. None Found Paint the words "NO PARKING" a compliant height within the access aisle. See Recommendation Stripe an access aisle 250 CA 11B- 502.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449067 0 Parking Exterior Parking Lot Less Than Minimum Required Parking Spaces The minimum number of accessible parking spaces are not provided in the parking lot. 1.00 spaces Re-stripe any existing parking spaces marked accessible and create additional accessible parking spaces. At least 3.00 spaces -2.00 spaces Paint ground markings and install a post mounted sign 370 ADA 208, 208.2, CA 11B-208.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449068 0 Parking Exterior Parking Lot Parking Lot Warning Sign There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. None Found Provide compliant signage regarding unauthorized use of accessible parking spaces. See Recommendation Install post mounted sign 250 CA 11B- 502.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449021 0 Curb Ramps Exterior Curb Ramp Next to Parking Lot Detectable Warnings The curb ramp does not provide a detectable warning surface which includes truncated domes. Not Found Provide compliant detectable warnings to surface. See Recommendation Provide detectable warning to surface 248 CA 11B- 406.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449022 0 Curb Ramps Exterior Curb Ramp Next to Parking Lot Contrasting Finish The surface of the curb ramp does not have a finish that contrasts with the adjacent sidewalk. Not Found Provide the surface on the curb ramp that contrasts with the adjacent sidewalk. See Recommendation Apply contrasting finish to surface 155 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449023 0 Curb Ramps Exterior Curb Ramp Next to Parking Lot Curb Ramp Slope The running slope is greater than allowed. 12.80 percent Provide a compliant curb ramp. Up to 8.33 percent 4.47 percent Install curb ramp 1300 ADA 406, 406.1, 405.2, CA 11B-406.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449024 0 Curb Ramps Exterior Curb Ramp Next to Parking Lot Left Side Flare Slope The slope of the curb ramp left side flare is greater than allowed. 16.20 percent Provide curb ramp side flares with a compliant slope. Up to 10.00 percent 6.20 percent Install flared sides 1300 ADA 406.3, CA 11B-406.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449025 0 Curb Ramps Exterior Curb Ramp Next to Parking Lot Bottom Landing Bottom Landing Slope The bottom landing of the curb ramp is on the street, and the slope of the bottom landing is not compliant. 9.60 percent Ensure the bottom landing slope is compliant and provides a smooth transition. Up to 5.00 percent 4.60 percent Repave landing 1260 ADA 406, 406.2, CA 11B-406.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449026 0 Curb Ramps Exterior Curb Ramp Next to Parking Lot Top Landing Top Landing Clear Length - Landings There is not enough top landing clear length. 0.00 inches Provide a level top landing with enough clear length. At least 48.00 inches -48.00 inches Provide compliant landing 240 ADA 406, 406.4, CA 11B-406.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449045 0 Curb Ramps Exterior Curb Ramp Next to West Entrance Next to Special Enforcement Team Detectable Warnings The curb ramp does not provide a detectable warning surface which includes truncated domes. Not Found Provide compliant detectable warnings to surface. See Recommendation Provide detectable warning to surface 248 CA 11B- 406.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449046 0 Curb Ramps Exterior Curb Ramp Next to West Entrance Next to Special Enforcement Team Contrasting Finish The surface of the curb ramp does not have a finish that contrasts with the adjacent sidewalk. Not Found Provide the surface on the curb ramp that contrasts with the adjacent sidewalk. See Recommendation Apply contrasting finish to surface 155 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449047 0 Curb Ramps Exterior Curb Ramp Next to West Entrance Next to Special Enforcement Team Curb Ramp Slope The running slope is greater than allowed. 9.90 percent Provide a compliant curb ramp. Up to 8.33 percent 1.57 percent Install curb ramp 1300 ADA 406, 406.1, 405.2, CA 11B-406.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449048 0 Curb Ramps Exterior Curb Ramp Next to West Entrance Next to Special Enforcement Team Left Side Flare Slope The slope of the curb ramp left side flare is greater than allowed. 11.40 percent Provide curb ramp side flares with a compliant slope. Up to 10.00 percent 1.40 percent Install flared sides 1300 ADA 406.3, CA 11B-406.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449049 0 Curb Ramps Exterior Curb Ramp Next to West Entrance Next to Special Enforcement Team Bottom Landing Bottom Landing Slope The bottom landing of the curb ramp is on the street, and the slope of the bottom landing is not compliant. 6.30 percent Ensure the bottom landing slope is compliant and provides a smooth transition. Up to 5.00 percent 1.30 percent Repave landing 1260 ADA 406, 406.2, CA 11B-406.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449050 0 Curb Ramps Exterior Curb Ramp Next to West Entrance Next to Special Enforcement Team Bottom Landing Bottom Landing Change in Level The transition from the bottom of the curb ramp to the walk, gutter, or street is abrupt. 0.62 inches Patch the transition area at the bottom of the curb ramp so that the transition is flush and free of abrupt changes. Up to 0.50 inches 0.12 inches Patch lip at curb ramp 255 ADA 406.2, 406.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445355 0 Path of Travel 2nd Floor Hallway Next to Chief of Police Fire Extinguisher Protruding Objects - Protrusion Limit The leading edge of the item protrudes into the circulation route greater than permitted. 4.50 inches Install side extensions, modify, relocate, or lower the item so that it is not a protruding object into the circulation route. Up to 4.00 inches 0.50 inches Install wing walls or relocate object 640 ADA 307, 307.2, CA 11B-307.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445399 0 Path of Travel 1st Floor Hallway Next to Equipment Room Fire Extinguisher Protruding Objects - Protrusion Limit The leading edge of the item protrudes into the circulation route greater than permitted. 4.50 inches Install side extensions, modify, relocate, or lower the item so that it is not a protruding object into the circulation route. Up to 4.00 inches 0.50 inches Install wing walls or relocate object 640 ADA 307, 307.2, CA 11B-307.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449003 0 Path of Travel Exterior Path of Travel from the Accessible Space to Staff Entrance Across from Workout Room Exterior Walkway Walking Surface Cross Slope There are cross slopes greater than allowed on the primary path of travel. 7.50 percent for 13.00 feet Provide a compliant path of travel. Up to 2.08 percent 5.42 percent Install pathway 3600 ADA 402, 403.3, CA 11B-403.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449005 0 Path of Travel Exterior Path of Travel from the Public Right of Way to Main Entrance - Left Change in Level Change in Level There is a change in elevation greater than recommended value. 1.00 inches Ensure that the change in elevation is within the recommended value. Up to 0.25 inches 0.75 inches Provide smooth surface 150 ADA 303, 403.4, CA 11B-303,403.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449004 0 Path of Travel Exterior Path of Travel from the Public Right of Way to Main Entrance - Left Exterior Walkway Walking Surface Slope There are slopes greater than allowed maximum slope on the primary path of travel. 5.40 percent for 5.00 feet Provide a compliant path of travel. Up to 5.00 percent 0.40 percent Install pathway 3600 ADA 402, 403.3, CA 11B-403.3,402 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449044 0 Path of Travel Exterior Path of Travel from the Public Right of Way to Main Entrance - Right Exterior Walkway Walking Surface Cross Slope There are cross slopes greater than allowed on the primary path of travel. 3.00 percent for 5.00 feet Provide a compliant path of travel. Up to 2.08 percent 0.92 percent Install pathway 3600 ADA 402, 403.3, CA 11B-403.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448992 0 Path of Travel Exterior Path of Travel from the Public Right of Way to Staff Entrance Across from Workout Room Vehicular Traffic Crosswalks and Detectable Warnings There are no detectable warnings where the pedestrian route crosses vehicular traffic. None Found Provide detectable warnings. See Recommendation Install compliant detectable warnings 190 ADA 705, CA 11B-705.1,247.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448990 0 Path of Travel Exterior Path of Travel from the Public Right of Way to Staff Entrance Across from Workout Room Exterior Walkway Walking Surface Slope There are slopes greater than allowed maximum slope on the primary path of travel. 7.10 percent Provide a compliant path of travel. Up to 5.00 percent 2.10 percent Install pathway 3600 ADA 402, 403.3, CA 11B-403.3,402 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448991 0 Path of Travel Exterior Path of Travel from the Public Right of Way to Staff Entrance Across from Workout Room Exterior Walkway Walking Surface Cross Slope There are cross slopes greater than allowed on the primary path of travel. 2.90 percent for 36.00 feet Provide a compliant path of travel. Up to 2.08 percent 0.82 percent Install pathway 3600 ADA 402, 403.3, CA 11B-403.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445459 0 Path of Travel 2nd Floor Path of Travel in Chief of Police Grate Grating The elongated openings of the grating are not perpendicular to the dominant direction of travel. Not Accessible Replace the grating with a compliant grating, where the elongated openings are perpendicular to the dominant direction of travel. See Recommendation 1088 ADA 302, 302.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446382 0 Path of Travel 1st Floor Path of Travel in Report Writing Office Interior Corridor Walking Surface Slope There are slopes greater than allowed maximum slope on the primary path of travel. 20.20 percent Provide a compliant path of travel. Up to 5.00 percent 15.20 percent Install pathway 3600 ADA 402, 403.3, CA 11B-403.3,402 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446383 0 Path of Travel 1st Floor Path of Travel in Report Writing Office Interior Corridor Clear Width - Walking Surfaces The width of the path of travel is insufficient. 35.00 inches Widen the primary path of travel to provide the correct width. At least 36.00 inches -1.00 inches Widen pathway 3500 ADA 403.5, CA 11B-403.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449033 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 1 Vertical Clearance Height Ramp run does not have enough vertical clearance height. 69.00 inches Provide compliant vertical clearance for the ramp run. At least 80.00 inches -11.00 inches ADA 307.4, CA 11B-307.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449034 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 1 Handrails There are no handrails. None Found Provide a compliant handrail with a compliant distance between the handrail and the adjacent wall. See Recommendation Provide compliant handrail with extensions 2200 ADA 405, 405.8, 505.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449038 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 1 Bottom Landing Landing Slope The slope of the landing is greater than required. 3.00 percent Modify the landing to create a slope in any direction not exceeding the required maximum value. Up to 2.08 percent 0.92 percent Modify ramp landing 2872 ADA 402, 405.7, CA 11B-405.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449035 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 1 Intermediate Landing Landing Length The length of the landing is less than the required minimum length. 38.25 inches Modify or replace the landing to provide the minimum required length and width. At least 60.00 inches -21.75 inches 25.84 ADA 405.7, 405.7, CA 11B-405.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449036 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 1 Intermediate Landing Landing Slope The slope of the landing is greater than required. 7.10 percent Modify the landing to create a slope in any direction not exceeding the required maximum value. Up to 2.08 percent 5.02 percent Modify ramp landing 2872 ADA 402, 405.7, CA 11B-405.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449037 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 1 Intermediate Landing Landing Change in Level There is a change in elevation greater than allowed on the primary path of travel of the ramp that is not beveled. 0.50 inches Bevel the area or resurface the area to provide a smooth and level path of travel. 0.25 - 0.50 inches Patch pathway 1840 ADA 302, 303, 405.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449027 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 2 Ramp Run Width The width of the ramp is less than required. 38.50 inches Widen the run of the ramp so that it has minimum required width. At least 48.00 inches -9.50 inches Install new ramp 9515 ADA 405, 405.5, CA 11B-405.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449028 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 2 Ramp Run Slope The slope of the ramp is greater than the allowed slope. 8.70 percent Modify the run of the ramp to provide the required slope and cross slope. Up to 8.33 percent 0.37 percent Correct ramp slope 3600 ADA 405, 405.2, CA 11B-405.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449030 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 2 Left Handrail Handrail Extension The handrail extension is not parallel to the floor or ground surface. Not Parallel Provide compliant handrail extensions that are parallel to the floor or ground surface extending the required distance beyond the bottom of the ramp and return smoothly to the post or wall. See Recommendation Provide compliant handrail extensions 2400 ADA 405, 405.8, 505.10, CA 11B-405.8,505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449031 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 2 Right Handrail Handrail Extension The handrail extension is not parallel to the floor or ground surface. Not Parallel Provide compliant handrail extensions that are parallel to the floor or ground surface extending the required distance beyond the bottom of the ramp and return smoothly to the post or wall. See Recommendation Provide compliant handrail extensions 2400 ADA 405, 405.8, 505.10, CA 11B-405.8,505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449032 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 2 Right Handrail Handrail Extension Length There is not enough handrail extension beyond the top or bottom of the rail. 9.50 inches Provide compliant handrail extensions that are parallel to the floor or ground surface extending the required distance beyond the bottom of the ramp and return smoothly to the post or wall. At least 12.00 inches -2.50 inches Provide compliant handrail extensions 2400 ADA 405, 405.8, 505.10, CA 11B-405.8,505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449029 0 Ramps Exterior Ramp from the Public Right of Way to Main Entrance Run 2 Top Landing Landing Slope The slope of the landing is greater than required. 3.00 percent Modify the landing to create a slope in any direction not exceeding the required maximum value. Up to 2.08 percent 0.92 percent Modify ramp landing 2872 ADA 402, 405.7, CA 11B-405.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448984 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Left Handrail Handrail Near Wall The surface texture of the wall adjacent to the handrail is sharp and abrasive. Near Wall Modify the surface texture on the wall adjacent to the handrail so that the surface is smooth. See Recommendation Attach pipe railing to wall 2320 ADA 505, 505.8, 504.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448985 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Left Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 7.50 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -4.50 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448986 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448987 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448988 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Left Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448989 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Left Handrail Handrail Extension Length The handrail extension is not the required length. 5.50 inches Install a compliant extension to the handrail. At least 12.00 inches -6.50 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448978 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Right Handrail Handrail Near Wall The surface texture of the wall adjacent to the handrail is sharp and abrasive. Near Wall Modify the surface texture on the wall adjacent to the handrail so that the surface is smooth. See Recommendation Attach pipe railing to wall 2320 ADA 505, 505.8, 504.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448979 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Right Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 6.50 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -5.50 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448980 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Right Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448981 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448982 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Right Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 448983 0 Stairs Exterior Stairs from the Public Right of Way to Main Entrance Run 1 Right Handrail Handrail Extension Length The handrail extension is not the required length. 7.00 inches Install a compliant extension to the handrail. At least 12.00 inches -5.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449011 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Handrail on One Side There is no handrail provided on one side of the stairway. None Found Provide compliant handrails on the stairway. See Recommendation Add compliant handrail 1528 ADA 504, CA 11B-504.6,505.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449012 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Risers Height The risers on the stairway are not a compliant height. 7.50 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.50 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449013 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Are Risers Closed The risers on the stairway are open. Not Closed Close the riser openings on the stairway. Open risers are not permitted. See Recommendation Close risers 480 ADA 504, 504.3, CA 11B-504.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449014 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Riser Striping There is no detectable striping on each tread of the exterior stairway. None Found Provide compliant striping to each tread of the stairway. See Recommendation Add non-slip surface to stair tread 944 ADA 504, CA 11B-504.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449015 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Left Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 7.50 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -4.50 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449016 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449017 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449018 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Left Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449019 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Left Handrail Handrail Extension Length The handrail extension is not the required length. 7.50 inches Install a compliant extension to the handrail. At least 12.00 inches -4.50 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449020 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Run 1 Left Handrail Handrail Height The handrail is not mounted at the required height. 33.50 inches Provide handrail at the required height. 34.00 - 38.00 inches -0.50 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449010 0 Stairs Exterior Stairs from the Public Right of Way to Parking Lot Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446546 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Risers Height The risers on the stairway are not a compliant height. 7.75 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.75 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446547 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Left Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446548 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Left Handrail Bottom Handrail Extension There are no bottom handrail extensions provided. None Found Install handrail extension to the bottom of the handrail that extends beyond the bottom riser at least one tread depth. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 505.10, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446549 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Left Handrail Handrail Height The handrail is not mounted at the required height. 31.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -3.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446550 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Right Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446551 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446552 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Right Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446553 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Right Handrail Handrail Extension Length The handrail extension is not the required length. 2.00 inches Install a compliant extension to the handrail. At least 12.00 inches -10.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446554 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 1 Right Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446555 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Risers Height The risers on the stairway are not a compliant height. 7.50 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.50 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446561 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Left Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446562 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Left Handrail Handrail Extension The ends of the handrail are not rounded or returned smoothly to the wall or post. None Found Install handrail extensions that are rounded or returned smoothly to the wall post. See Recommendation Add compliant handrail 1916 ADA 504, 504.6, 505.10, CA 11B-504.6,505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446563 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Left Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 3.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -9.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446564 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446565 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446566 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Left Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446556 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Right Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446557 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Right Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 4.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -8.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446558 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Right Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446559 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446560 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Run 2 Right Handrail Handrail Height The handrail is not mounted at the required height. 31.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -3.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446545 0 Stairs 1st Floor Stairs Next to Equipment Room to 2nd Floor Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446368 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Handrail on One Side There is no handrail provided on one side of the stairway. None Found Provide compliant handrails on the stairway. See Recommendation Add compliant handrail 1528 ADA 504, CA 11B-504.6,505.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446369 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Right Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446370 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Right Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 6.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -6.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446371 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Right Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446372 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446373 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Right Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446374 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Right Handrail Handrail Extension Length The handrail extension is not the required length. 6.00 inches Install a compliant extension to the handrail. At least 12.00 inches -6.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446375 0 Stairs 1st Floor Stairs Next to North Entrance Run 1 Right Handrail Handrail Height The handrail is not mounted at the required height. 31.50 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.50 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446367 0 Stairs 1st Floor Stairs Next to North Entrance Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446503 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Risers Height The risers on the stairway are not a compliant height. 7.50 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.50 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446508 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Left Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 9.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -3.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446509 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446510 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446511 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Left Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446512 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Left Handrail Handrail Extension Length The handrail extension is not the required length. 8.00 inches Install a compliant extension to the handrail. At least 12.00 inches -4.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446513 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Left Handrail Handrail Height The handrail is not mounted at the required height. 32.50 inches Provide handrail at the required height. 34.00 - 38.00 inches -1.50 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446504 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446505 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Right Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446506 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Right Handrail Handrail Extension Length The handrail extension is not the required length. 8.00 inches Install a compliant extension to the handrail. At least 12.00 inches -4.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446507 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 1 Right Handrail Handrail Height The handrail is not mounted at the required height. 32.50 inches Provide handrail at the required height. 34.00 - 38.00 inches -1.50 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446514 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Risers Height The risers on the stairway are not a compliant height. 7.50 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.50 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446519 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Left Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 8.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -4.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446520 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446521 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446522 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Left Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446523 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Left Handrail Handrail Extension Length The handrail extension is not the required length. 8.00 inches Install a compliant extension to the handrail. At least 12.00 inches -4.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446524 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Left Handrail Handrail Height The handrail is not mounted at the required height. 31.50 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.50 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446515 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Right Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 6.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -6.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446516 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Right Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446517 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446518 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Run 2 Right Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446502 0 Stairs 1st Floor Stairs Next to Special Enforcement Team Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446304 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Left Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446305 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Left Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 6.50 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -5.50 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446306 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446307 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446308 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Left Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446309 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Left Handrail Handrail Extension Length The handrail extension is not the required length. 6.00 inches Install a compliant extension to the handrail. At least 12.00 inches -6.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446310 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Left Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446311 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Right Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446312 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Right Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 5.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -7.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446313 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Right Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446314 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446315 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Right Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446316 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Right Handrail Handrail Extension Length The handrail extension is not the required length. 7.00 inches Install a compliant extension to the handrail. At least 12.00 inches -5.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446317 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Run 1 Right Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446303 0 Stairs 1st Floor Stairs Next to Staff Entrance Across from Workout Room Exterior Entrance Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446324 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Stair Run Width The width of the stairway does not meet the minimum required width. 42.75 inches Install a stairway with a minimum width as required. At least 44.00 inches -1.25 inches Modify width 4816 ADA 210, 504, CA 11B-1009.1,210,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446325 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Risers Height The risers on the stairway are not a compliant height. 7.50 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.50 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446329 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Left Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446330 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Left Handrail Bottom Handrail Extension There are no bottom handrail extensions provided. None Found Install handrail extension to the bottom of the handrail that extends beyond the bottom riser at least one tread depth. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 505.10, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446331 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Left Handrail Handrail Height The handrail is not mounted at the required height. 31.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -3.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446326 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Right Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446327 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Right Handrail Bottom Handrail Extension There are no bottom handrail extensions provided. None Found Install handrail extension to the bottom of the handrail that extends beyond the bottom riser at least one tread depth. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 505.10, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446328 0 Stairs 1st Floor Stairs to Chief of Police Run 1 Right Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446332 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Stair Run Width The width of the stairway does not meet the minimum required width. 42.50 inches Install a stairway with a minimum width as required. At least 44.00 inches -1.50 inches Modify width 4816 ADA 210, 504, CA 11B-1009.1,210,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446333 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Risers Height The risers on the stairway are not a compliant height. 7.50 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.50 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446334 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Left Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.25 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.25 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446335 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446336 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446337 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Left Handrail Handrail Height The handrail is not mounted at the required height. 31.50 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.50 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446338 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Right Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446339 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Right Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 3.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -9.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446340 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Right Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446341 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446342 0 Stairs 1st Floor Stairs to Chief of Police Run 2 Right Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446323 0 Stairs 1st Floor Stairs to Chief of Police Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449088 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Risers Height The risers on the stairway are not a compliant height. 7.50 inches Modify or replace the stairs to provide compliant riser height. 4.00 - 7.00 inches 0.50 inches ADA 504.2, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449089 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Risers Height The height of the risers are not uniform. Not Uniform Modify or replace the stairs to provide uniform riser height. See Recommendation Install stairway 8520 ADA 504, CA 11B-504.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449090 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Risers Striping Width The striping on each tread of the stairway is not at a compliant width. 5.50 inches Provide compliant striping on each tread of the stairway. 2.00 - 4.00 inches 1.50 inches Add color slip resistant strip to stair treads 460 ADA 504, CA 11B-504.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449091 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Left Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449092 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Left Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 0.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -12.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449093 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Left Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449094 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Left Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449095 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Left Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449096 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Left Handrail Handrail Extension Length The handrail extension is not the required length. 5.00 inches Install a compliant extension to the handrail. At least 12.00 inches -7.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449097 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Left Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449098 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Right Handrail Handrail Diameter The diameter of the handrail is not within the required range. 2.50 inches Provide a compliant handrail with a diameter within the required range. 1.25 - 2.00 inches 0.50 inches Attach pipe railing to wall 2320 ADA 505, 504.6, 505.7, CA 11B-505.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449099 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Right Handrail Handrail Extension Length The top handrail extension is not the required length beyond the top riser. 0.00 inches Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. At least 12.00 inches -12.00 inches Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449100 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Right Handrail Handrail Extension The top handrail extension of the stairway is not parallel with the floor surface at the top landing. Not Parallel Install a compliant handrail extension to the top of the handrail that extends beyond the top riser and is parallel to the floor surface of the landing. See Recommendation Add compliant extension to existing railing 800 ADA 504, 504.6, 505.10, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449101 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Right Handrail Handrail Bottom Extension The bottom handrail does not extend the depth of one stair tread beyond the bottom step. None Found Provide a compliant handrail extension. See Recommendation Add compliant extension to existing railing 1425 ADA 504, 504.6, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449102 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Right Handrail Handrail Extension The handrail extension is not parallel with the floor surface at the bottom landing. Not Parallel Install a compliant extension to the handrail. See Recommendation Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449103 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Right Handrail Handrail Extension Length The handrail extension is not the required length. 4.00 inches Install a compliant extension to the handrail. At least 12.00 inches -8.00 inches Add compliant extension to existing railing 627 ADA 504, CA 11B-505.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449104 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Run 1 Right Handrail Handrail Height The handrail is not mounted at the required height. 32.00 inches Provide handrail at the required height. 34.00 - 38.00 inches -2.00 inches Add compliant handrail 1528 ADA 504, 504.6, 505.4, CA 11B-504.6,505 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449087 0 Stairs Exterior Stairs to Lecture Room Exterior Entrance Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446377 0 Stairs 1st Floor Stairs to Workout Room Run 1 Handrails There are no handrails provided on the stairway. None Found Provide compliant handrails. See Recommendation Add compliant handrail 1528 ADA 504, 505.2, 504.6, CA 11B-504.6,505.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446378 0 Stairs 1st Floor Stairs to Workout Room Run 1 Are Risers Closed The risers on the stairway are open. Not Closed Close the riser openings on the stairway. Open risers are not permitted. See Recommendation Close risers 480 ADA 504, 504.3, CA 11B-504.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446376 0 Stairs 1st Floor Stairs to Workout Room Stairway is marked as primary access. There is no other means of vertical access. No Access Provide a compliant means of vertical access. See Recommendation Modify stairway 4816 ADA 210, 504, 206.2, 402.2, CA 11B-206.2,210,402.2,504 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445446 0 Doors 2nd Floor Administration Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445444 0 Doors 2nd Floor Administration Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445200 0 Doors 2nd Floor Administrative Analyst Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 50.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -10.00 inches Install automatic door opener 2921 Notes : Desk Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445199 0 Doors 2nd Floor Administrative Analyst Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445395 0 Doors 2nd Floor Administrative Assistant Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 42.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -18.00 inches Install automatic door opener 2921 Notes : Desk Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445394 0 Doors 2nd Floor Administrative Assistant Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445487 0 Doors 2nd Floor Administrative Captain Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 8.37 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -9.63 inches Install automatic door opener 4000 Notes : Bookcase Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445486 0 Doors 2nd Floor Administrative Captain Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445484 0 Doors 2nd Floor Administrative Captain Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445261 0 Doors 2nd Floor Administrative Lieutenant Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445259 0 Doors 2nd Floor Administrative Lieutenant Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445214 0 Doors 2nd Floor Administrative Sergeant Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 41.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -19.00 inches Install automatic door opener 2921 Notes : File Cabinet Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445213 0 Doors 2nd Floor Administrative Sergeant Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445211 0 Doors 2nd Floor Administrative Sergeant Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446320 0 Doors 1st Floor Booking Area - Exterior Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446321 0 Doors 1st Floor Booking Area - Exterior Single Knob Door Opening Pressure The door opening force for this door is greater than allowed. 9.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 4.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446322 0 Doors 1st Floor Booking Area - Exterior Door Threshold The height of the threshold at the entrance door is greater than allowed. 7.00 inches Modify or replace the threshold to provide the recommended height. Up to 0.50 inches 6.50 inches Provide smooth transition 436 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446467 0 Doors 1st Floor Booking Area - Interior Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 4.75 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -13.25 inches Install automatic door opener 4000 Notes : Bench Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446465 0 Doors 1st Floor Booking Area - Interior Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446466 0 Doors 1st Floor Booking Area - Interior Single Knob Door Opening Pressure The door opening force for this door is greater than allowed. 8.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 3.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445491 0 Doors 2nd Floor Chief of Police Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 8.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -10.00 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445490 0 Doors 2nd Floor Chief of Police Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445488 0 Doors 2nd Floor Chief of Police Door Opening Width The clear opening width of the door is less than required. 29.25 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.75 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445274 0 Doors 2nd Floor Communications Manager Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 7.25 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -10.75 inches Install automatic door opener 4000 Notes : Bookcase Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445273 0 Doors 2nd Floor Communications Manager Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445271 0 Doors 2nd Floor Communications Manager Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445397 0 Doors 1st Floor Crime Lab Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 8.50 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -9.50 inches Install automatic door opener 4000 Notes : Counter Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445246 0 Doors 1st Floor Crime Lab Office Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446366 0 Doors 1st Floor Data Entry Next to Holding Cells Open Doorway Height The vertical clearance height of the open doorway is not compliant. 79.50 inches Provide a compliant open doorway at the location. At least 80.00 inches -0.50 inches Modify doorway 5600 ADA 307.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445352 0 Doors 2nd Floor Day Watch Commander Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 4.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -14.00 inches Install automatic door opener 4000 Notes : Bench Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445351 0 Doors 2nd Floor Day Watch Commander Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445349 0 Doors 2nd Floor Day Watch Commander Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445464 0 Doors 1st Floor Digital Evidence Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 41.50 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -18.50 inches Install automatic door opener 2921 Notes : Desk Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445463 0 Doors 1st Floor Digital Evidence Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445457 0 Doors 2nd Floor Door Between Chief of Police & Administration Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 50.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -10.00 inches Install automatic door opener 2921 Notes : Furniture Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445456 0 Doors 2nd Floor Door Between Chief of Police & Administration Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445454 0 Doors 2nd Floor Door Between Chief of Police & Administration Door Opening Width The clear opening width of the door is less than required. 25.25 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -6.75 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446528 0 Doors 1st Floor Doorway Across from Interview Room 1 in Lobby Push Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the push side of the door. 1.50 inches Provide the recommended latch side clearance on the push side of the door. At least 12.00 inches -10.50 inches Install automatic door opener 2921 ADA 404, 404.2, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446391 0 Doors 1st Floor Doorway Next to Administrative Assistant Push Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the push side of the door. 3.00 inches Provide the recommended latch side clearance on the push side of the door. At least 12.00 inches -9.00 inches Install automatic door opener 2921 ADA 404, 404.2, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449042 0 Doors 2nd Floor Doorway Next to Interview Room 2 in Lobby Open Doorway Height The vertical clearance height of the open doorway is not compliant. 79.25 inches Provide a compliant open doorway at the location. At least 80.00 inches -0.75 inches Modify doorway 5600 ADA 307.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445378 0 Doors 1st Floor Doorway Next to Lecture Room Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 12.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -6.00 inches Install automatic door opener 4000 Notes : Shelving Unit Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445379 0 Doors 1st Floor Doorway Next to Lecture Room Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 59.25 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -0.75 inches Install automatic door opener 2921 Notes : Shelving Unit Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445377 0 Doors 1st Floor Doorway Next to Lecture Room Push / Pull Door Opening Pressure The door opening force for this door is greater than allowed. 8.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 3.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445431 0 Doors 2nd Floor Field Supervisor Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 40.50 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -19.50 inches Install automatic door opener 2921 Notes : Mini Fridge Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445430 0 Doors 2nd Floor Field Supervisor Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445428 0 Doors 2nd Floor Field Supervisor Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449053 0 Doors Exterior Gate Next to Stairs from the Public Right of Way to Parking Lot Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 5.00 inches Provide the recommended latch side clearance for the door. At least 24.00 inches -19.00 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449054 0 Doors Exterior Gate Next to Stairs from the Public Right of Way to Parking Lot Pull Side Floor Surface Slope There is no level landing at this door. 6.40 percent Provide a level landing. Up to 2.08 percent 4.32 percent Correct slopes 1500 ADA 302, 404, 305, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449051 0 Doors Exterior Gate Next to Stairs from the Public Right of Way to Parking Lot Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449052 0 Doors Exterior Gate Next to Stairs from the Public Right of Way to Parking Lot Single Knob Bottom Door Panel The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. None Found Install a smooth uninterrupted surface or panel on the push side, extending the full width of the door or gate. See Recommendation Install Panel 400 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446440 0 Doors 1st Floor Holding Cell - Left Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 2.50 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -15.50 inches Install automatic door opener 4000 Notes : Furniture Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446439 0 Doors 1st Floor Holding Cell - Left Push / Pull Height Door hardware is not mounted at the correct height. 54.00 inches Mount the door hardware at the recommended height. 34.00 - 44.00 inches 10.00 inches Replace door hardware 280 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446441 0 Doors 1st Floor Holding Cell - Left Push Side Front Approach Clear Floor Space Width There is not enough clear floor space provided at the push side of the door . 34.62 inches Provide the recommended clear floor space on the push side of the door. At least 36.00 inches -1.38 inches Install automatic door opener 4000 ADA 404, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446437 0 Doors 1st Floor Holding Cell - Left Door Opening Width The clear opening width of the door is less than required. 28.75 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -3.25 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446415 0 Doors 1st Floor Holding Cell - Right Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 4.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -14.00 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446414 0 Doors 1st Floor Holding Cell - Right Push / Pull Height Door hardware is not mounted at the correct height. 54.00 inches Mount the door hardware at the recommended height. 34.00 - 44.00 inches 10.00 inches Replace door hardware 280 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446412 0 Doors 1st Floor Holding Cell - Right Door Opening Width The clear opening width of the door is less than required. 29.00 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -3.00 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445257 0 Doors 2nd Floor Interview Room Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446430 0 Doors 2nd Floor Interview Room 1 in Lobby Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 48.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -12.00 inches Install automatic door opener 2921 Notes : Table Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446429 0 Doors 2nd Floor Interview Room 1 in Lobby Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446443 0 Doors 2nd Floor Interview Room 2 in Lobby Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 52.50 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -7.50 inches Install automatic door opener 2921 Notes : Table Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446442 0 Doors 2nd Floor Interview Room 2 in Lobby Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445467 0 Doors 2nd Floor Interview Room Next to Investigations Lieutenant Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446570 0 Doors 1st Floor Intoxilyzer Room Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 8.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -10.00 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446571 0 Doors 1st Floor Intoxilyzer Room Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 25.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -35.00 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446569 0 Doors 1st Floor Intoxilyzer Room Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445297 0 Doors 2nd Floor Investigations Lieutenant Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 50.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -10.00 inches Install automatic door opener 2921 Notes : Desk Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445295 0 Doors 2nd Floor Investigations Lieutenant Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445236 0 Doors 1st Floor Lecture Room Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 12.25 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -5.75 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445234 0 Doors 1st Floor Lecture Room Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446433 0 Doors 1st Floor Lecture Room Exterior Entrance Door Threshold The height of the threshold at the entrance door is greater than allowed. 1.25 inches Modify or replace the threshold to provide the recommended height. Up to 0.50 inches 0.75 inches Provide smooth transition 436 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446434 0 Doors 1st Floor Lecture Room Exterior Entrance Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 6.50 inches Provide the recommended latch side clearance for the door. At least 24.00 inches -17.50 inches Install automatic door opener 2921 Notes : Stairs Obstructs Latch Side Clearance. Wall Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446435 0 Doors 1st Floor Lecture Room Exterior Entrance Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 50.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -10.00 inches Install automatic door opener 2921 Notes : Stairs Obstructs Latch Side Clearance. Wall Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446436 0 Doors 1st Floor Lecture Room Exterior Entrance Pull Side Floor Surface Slope There is no level landing at this door. 5.50 percent Provide a level landing. Up to 2.08 percent 3.42 percent Correct slopes 1500 Notes : Stairs Obstructs Latch Side Clearance. Wall Obstructs Clear Floor Space Length. ADA 302, 404, 305, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446432 0 Doors 1st Floor Lecture Room Exterior Entrance Push Bar / D Handle Door Opening Pressure The door opening force for this door is greater than allowed. 11.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 6.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445345 0 Doors 1st Floor Locker Room Entrance - Exterior Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 9.50 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -8.50 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445346 0 Doors 1st Floor Locker Room Entrance - Exterior Push Side Latch Approach Clear Floor Space Width There is not enough clear floor space provided at the push side of the door . 43.25 inches Provide the recommended clear floor space on the push side of the door. At least 48.00 inches -4.75 inches Install automatic door opener 4000 ADA 404, 404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445343 0 Doors 1st Floor Locker Room Entrance - Exterior Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445476 0 Doors 1st Floor Locker Room Entrance - Interior Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 10.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -8.00 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445473 0 Doors 1st Floor Locker Room Entrance - Interior Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446448 0 Doors 1st Floor Locker Room Entrance Across Report Writing - Exterior Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 9.25 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -8.75 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446446 0 Doors 1st Floor Locker Room Entrance Across Report Writing - Exterior Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446343 0 Doors 1st Floor Locker Room Entrance Across Report Writing - Interior Open Doorway Height The vertical clearance height of the open doorway is not compliant. 79.50 inches Provide a compliant open doorway at the location. At least 80.00 inches -0.50 inches Modify doorway 5600 ADA 307.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446344 0 Doors 1st Floor Locker Room Entrance Across Report Writing - Interior Doorway Opening Width The clear opening width of the doorway is not compliant. 31.00 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -1.00 inches Provide a compliant doorway 1800 ADA 404, 404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446530 0 Doors 2nd Floor Main Entrance Pull Side Floor Surface Slope There is no level landing at this door. 3.00 percent Provide a level landing. Up to 2.08 percent 0.92 percent Correct slopes 1500 ADA 302, 404, 305, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445382 0 Doors 2nd Floor Mens Restroom Next to Investigations Lieutenant Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 44.50 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -15.50 inches Install automatic door opener 2921 Notes : Lavatory Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445386 0 Doors 1st Floor Mens Restroom Next to Locker Room Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 54.25 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -5.75 inches Install automatic door opener 2921 Notes : Partition Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445383 0 Doors 1st Floor Mens Restroom Next to Locker Room Door Opening Width The clear opening width of the door is less than required. 27.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -4.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445332 0 Doors 2nd Floor Mens Restroom Next to Records Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 10.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -8.00 inches Install automatic door opener 4000 Notes : Lavatory Obstructs Latch Side Clearance. Toilet Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445334 0 Doors 2nd Floor Mens Restroom Next to Records Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 41.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -19.00 inches Install automatic door opener 2921 Notes : Lavatory Obstructs Latch Side Clearance. Toilet Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445331 0 Doors 2nd Floor Mens Restroom Next to Records Push Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the push side of the door. 4.75 inches Provide the recommended latch side clearance on the push side of the door. At least 12.00 inches -7.25 inches Install automatic door opener 2921 Notes : File Cabinet Obstructs Latch Side Clearance. ADA 404, 404.2, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445333 0 Doors 2nd Floor Mens Restroom Next to Records Push Side Front Approach Clear Floor Space Width There is not enough clear floor space provided at the push side of the door . 32.50 inches Provide the recommended clear floor space on the push side of the door. At least 36.00 inches -3.50 inches Install automatic door opener 4000 Notes : File Cabinet Obstructs Latch Side Clearance. ADA 404, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445326 0 Doors 2nd Floor Mens Restroom Next to Records Door Opening Width The clear opening width of the door is less than required. 25.00 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -7.00 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445325 0 Doors 2nd Floor Neighborhood Outreach Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445323 0 Doors 2nd Floor Neighborhood Outreach Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445193 0 Doors 2nd Floor Night Watch Commander Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445191 0 Doors 2nd Floor Night Watch Commander Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446484 0 Doors 1st Floor North Entrance Next to Rain Gear Door Threshold The height of the threshold at the entrance door is greater than allowed. 0.87 inches Modify or replace the threshold to provide the recommended height. Up to 0.50 inches 0.37 inches Provide smooth transition 436 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446485 0 Doors 1st Floor North Entrance Next to Rain Gear Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 0.00 inches Provide the recommended latch side clearance for the door. At least 24.00 inches -24.00 inches Install automatic door opener 2921 Notes : Wall Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446486 0 Doors 1st Floor North Entrance Next to Rain Gear Pull Side Floor Surface Slope There is no level landing at this door. 4.40 percent Provide a level landing. Up to 2.08 percent 2.32 percent Correct slopes 1500 Notes : Wall Obstructs Latch Side Clearance. ADA 302, 404, 305, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 446487 0 Doors 1st Floor North Entrance Next to Rain Gear Pull Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 Notes : Wall Obstructs Latch Side Clearance. ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445472 0 Doors 2nd Floor Offices Next to Investigations Lieutenant Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 4.75 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -13.25 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445469 0 Doors 2nd Floor Offices Next to Investigations Lieutenant Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445470 0 Doors 2nd Floor Offices Next to Investigations Lieutenant Single Knob Height Door hardware is not mounted at the correct height. 46.50 inches Mount the door hardware at the recommended height. 34.00 - 44.00 inches 2.50 inches Replace door hardware 280 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445471 0 Doors 2nd Floor Offices Next to Investigations Lieutenant Single Knob Door Lock The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Not Accessible Provide a compliant door lock for the door that does not require tight grasping, pinching, or twisting of the wrist to operate. See Recommendation Provide door lock 310 ADA 404.2, 309.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445468 0 Doors 2nd Floor Open Doorway Next to Records Supervisor Open Doorway Height The vertical clearance height of the open doorway is not compliant. 79.50 inches Provide a compliant open doorway at the location. At least 80.00 inches -0.50 inches Modify doorway 5600 ADA 307.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445403 0 Doors 2nd Floor Operations Captain Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 55.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -5.00 inches Install automatic door opener 2921 Notes : Desk Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445402 0 Doors 2nd Floor Operations Captain Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445400 0 Doors 2nd Floor Operations Captain Door Opening Width The clear opening width of the door is less than required. 29.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -2.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445373 0 Doors 1st Floor Physical Evidence Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445462 0 Doors 2nd Floor Programs Office Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 12.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -6.00 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445461 0 Doors 2nd Floor Programs Office Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 445493 0 Doors 1st Floor Property Office Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 53.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -7.00 inches Install automatic door opener 2921 Notes : Desk Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449009 0 Doors 2nd Floor Records Area Next to Lobby Counter Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 20.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -40.00 inches Install automatic door opener 2921 Notes : Copier Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 449008 0 Doors 2nd Floor Records Area Next to Lobby Counter Push Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the push side of the door. 3.50 inches Provide the recommended latch side clearance on the push side of the door. At least 12.00 inches -8.50 inches Install automatic door opener 2921 ADA 404, 404.2, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449006 0 Doors 2nd Floor Records Area Next to Lobby Counter Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445309 0 Doors 2nd Floor Records Offices Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 51.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -9.00 inches Install automatic door opener 2921 Notes : File Cabinet Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445308 0 Doors 2nd Floor Records Offices Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445498 0 Doors 2nd Floor Records Supervisor Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 8.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -10.00 inches Install automatic door opener 4000 Notes : Desk Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445499 0 Doors 2nd Floor Records Supervisor Push Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the push side of the door . 47.25 inches Provide the recommended clear floor space on the push side of the door. At least 48.00 inches -0.75 inches Install automatic door opener 4000 Notes : File Cabinet Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445496 0 Doors 2nd Floor Records Supervisor Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445494 0 Doors 2nd Floor Records Supervisor Door Opening Width The clear opening width of the door is less than required. 29.00 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -3.00 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445197 0 Doors 1st Floor Report Writing Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 2.00 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -16.00 inches Install automatic door opener 4000 Notes : Stair Obstructs Clear Floor Space Length. Stair Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445198 0 Doors 1st Floor Report Writing Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 47.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -13.00 inches Install automatic door opener 2921 Notes : Stair Obstructs Clear Floor Space Length. Stair Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445195 0 Doors 1st Floor Report Writing Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445231 0 Doors 1st Floor Shower Room Next to Locker Room Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 9.50 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -8.50 inches Install automatic door opener 4000 Notes : Bench Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445229 0 Doors 1st Floor Shower Room Next to Locker Room Door Opening Width The clear opening width of the door is less than required. 27.12 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -4.88 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445426 0 Doors 1st Floor Special Enforcement Team Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 13.75 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -4.25 inches Install automatic door opener 4000 Notes : Locker Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445427 0 Doors 1st Floor Special Enforcement Team Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 50.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -10.00 inches Install automatic door opener 2921 Notes : Locker Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446348 0 Doors 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Door Threshold The height of the threshold at the entrance door is greater than allowed. 0.75 inches Modify or replace the threshold to provide the recommended height. Up to 0.50 inches 0.25 inches Provide smooth transition 436 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446350 0 Doors 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 0.00 inches Provide the recommended latch side clearance for the door. At least 24.00 inches -24.00 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446352 0 Doors 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Pull Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446349 0 Doors 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Push Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the push side of the door. 4.50 inches Provide the recommended latch side clearance on the push side of the door. At least 12.00 inches -7.50 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446351 0 Doors 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Push Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446445 0 Doors 1st Floor Tactical Stoage Hallway Open Doorway Height The vertical clearance height of the open doorway is not compliant. 79.25 inches Provide a compliant open doorway at the location. At least 80.00 inches -0.75 inches Modify doorway 5600 ADA 307.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445358 0 Doors 1st Floor Training Room - Exterior Door Threshold The height of the threshold at the entrance door is greater than allowed. 1.50 inches Modify or replace the threshold to provide the recommended height. Up to 0.50 inches 1.00 inches Provide smooth transition 436 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445359 0 Doors 1st Floor Training Room - Exterior Push Side Floor Surface Slope There is no level landing at this door. 3.80 percent Provide a level landing. Up to 2.08 percent 1.72 percent Correct slopes 1500 ADA 302, 404, 305, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445392 0 Doors 2nd Floor Unisex Restroom in Chief of Police Office Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445393 0 Doors 2nd Floor Unisex Restroom in Chief of Police Office Single Knob Door Lock The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Not Accessible Provide a compliant door lock for the door that does not require tight grasping, pinching, or twisting of the wrist to operate. See Recommendation Provide door lock 310 ADA 404.2, 309.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445390 0 Doors 2nd Floor Unisex Restroom in Chief of Police Office Door Opening Width The clear opening width of the door is less than required. 25.25 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -6.75 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449060 0 Doors 2nd Floor Unisex Restroom in Lobby Push Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the push side of the door. 9.75 inches Provide the recommended latch side clearance on the push side of the door. At least 12.00 inches -2.25 inches Install automatic door opener 2921 Notes : Counter Obstructs Latch Side Clearance. ADA 404, 404.2, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446536 0 Doors 1st Floor Unisex Restroom Next to Holding Cells Push Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the push side of the door . 39.50 inches Provide the recommended clear floor space on the push side of the door. At least 48.00 inches -8.50 inches Install automatic door opener 4000 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446537 0 Doors 1st Floor Unisex Restroom Next to Holding Cells Push Side Front Approach Clear Floor Space Width There is not enough clear floor space provided at the push side of the door . 24.00 inches Provide the recommended clear floor space on the push side of the door. At least 36.00 inches -12.00 inches Install automatic door opener 4000 ADA 404, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446534 0 Doors 1st Floor Unisex Restroom Next to Holding Cells Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446535 0 Doors 1st Floor Unisex Restroom Next to Holding Cells Single Knob Door Lock The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Not Accessible Provide a compliant door lock for the door that does not require tight grasping, pinching, or twisting of the wrist to operate. See Recommendation Provide door lock 310 ADA 404.2, 309.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446532 0 Doors 1st Floor Unisex Restroom Next to Holding Cells Door Opening Width The clear opening width of the door is less than required. 21.00 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -11.00 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449080 0 Doors 1st Floor West Entrance Next to Special Enforcement Team Lever Door Opening Pressure The door opening force for this door is greater than allowed. 13.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 8.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449083 0 Doors 1st Floor West Entrance Next to Special Enforcement Team Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 5.00 inches Provide the recommended latch side clearance for the door. At least 24.00 inches -19.00 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449085 0 Doors 1st Floor West Entrance Next to Special Enforcement Team Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 51.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -9.00 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449082 0 Doors 1st Floor West Entrance Next to Special Enforcement Team Push Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the push side of the door. 5.00 inches Provide the recommended latch side clearance on the push side of the door. At least 12.00 inches -7.00 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449084 0 Doors 1st Floor West Entrance Next to Special Enforcement Team Push Side Floor Mat An unstable floor mat is provided at the door landing. Not Compliant Provide a compliant floor mat for the door. See Recommendation Install mat that grips to the floor surface 126 ADA 403.2, 302.1, CA 11B-302.1,403.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445374 0 Doors 2nd Floor Womens Restroom Next to Investigations Lieutenant Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 45.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -15.00 inches Install automatic door opener 2921 Notes : Lavatory Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446410 0 Doors 1st Floor Womens Restroom Next to Lecture Room Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 20.75 inches Provide the recommended latch side clearance for the door. At least 24.00 inches -3.25 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446411 0 Doors 1st Floor Womens Restroom Next to Lecture Room Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 36.00 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -24.00 inches Install automatic door opener 2921 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446409 0 Doors 1st Floor Womens Restroom Next to Lecture Room Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446407 0 Doors 1st Floor Womens Restroom Next to Lecture Room Door Opening Width The clear opening width of the door is less than required. 27.25 inches Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. At least 32.00 inches -4.75 inches Widen existing door and add accessible hardware 1750 ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445381 0 Doors 2nd Floor Womens Restroom Next to Staff Lounge Push / Pull Door Opening Pressure The door opening force for this door is greater than allowed. 6.00 pounds Adjust the closer on the door to meet the door opening force requirements. Up to 5.00 pounds 1.00 pounds Adjust door closer pressure 25 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446387 0 Doors 1st Floor Workout Room Exterior Entrance Pull Side Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 0.00 inches Provide the recommended latch side clearance for the door. At least 24.00 inches -24.00 inches Install automatic door opener 2921 Notes : Stairs Obstructs Clear Floor Space Length. Stairs Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446389 0 Doors 1st Floor Workout Room Exterior Entrance Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 49.25 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -10.75 inches Install automatic door opener 2921 Notes : Stairs Obstructs Clear Floor Space Length. Stairs Obstructs Latch Side Clearance. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446388 0 Doors 1st Floor Workout Room Exterior Entrance Push Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the push side of the door . 18.00 inches Provide the recommended clear floor space on the push side of the door. At least 48.00 inches -30.00 inches Install automatic door opener 4000 Notes : Workout Equipment Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446385 0 Doors 1st Floor Workout Room Exterior Entrance Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446406 0 Doors 1st Floor Workout Room Next to Mens Locker Room Pull Side Front Approach Clear Floor Space Length There is not enough clear floor space provided at the pull side of the door. 32.75 inches Provide the recommended clear floor space on the pull side of the door. At least 60.00 inches -27.25 inches Install automatic door opener 2921 Notes : Workout Equipment Obstructs Clear Floor Space Length. ADA 404, 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446405 0 Doors 1st Floor Workout Room Next to Mens Locker Room Single Knob Accessible Hardware The door opening hardware is not accessible. Not Accessible Provide accessible hardware on the door. See Recommendation Replace existing lock set with lever handled lock set 800 ADA 404.2, CA 11B-404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446399 0 Counters 1st Floor Counter in Intoxilyzer Room Counter Length The length of the counter or desk does not comply with length requirements. 30.00 inches Provide a counter or desk with the required length. At least 36.00 inches -6.00 inches Provide compliant counter 545 Notes : Counter Protrudes 24 Into the Path of Travel. CA 11B- 904.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446400 0 Counters 1st Floor Counter in Intoxilyzer Room Protruding Object The counter is a protruding object. See Above Adjust the counter so that it is no longer a protruding object. See Recommendation Adjust the counter 450 Notes : Counter Protrudes 24 Into the Path of Travel. ADA 902, 307.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446401 0 Counters 1st Floor Counter in Intoxilyzer Room Clear Floor Space Width The clear floor space width at the counter is not compliant. 26.00 inches Provide compliant clear floor space at the counter. At least 30.00 inches -4.00 inches 1260 Notes : Counter Protrudes 24 Into the Path of Travel. ADA 904.3, 305, CA 11B-904.4,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446572 0 Counters 1st Floor Counter in Report Writing Counter Height The height of the counter or desk does not comply with height requirements. 45.50 inches Provide a portion of counter at the compliant height. 28.00 - 34.00 inches 11.50 inches Provide compliant counter 3500 Notes : Counter Protrudes 5 Into the Path of Travel. ADA 902, 904, CA 11B-904.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446573 0 Counters 1st Floor Counter in Report Writing Protruding Object The counter is a protruding object. See Above Adjust the counter so that it is no longer a protruding object. See Recommendation Adjust the counter 450 Notes : Counter Protrudes 5 Into the Path of Travel. ADA 902, 307.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449055 0 Counters 2nd Floor Fingerprint Counter in Lobby Counter Height The height of the counter or desk does not comply with height requirements. 42.00 inches Provide a portion of counter at the compliant height. 28.00 - 34.00 inches 8.00 inches Provide compliant counter 3500 Notes : Counter Protrudes 15 Into the Path of Travel. ADA 902, 904, CA 11B-904.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449056 0 Counters 2nd Floor Fingerprint Counter in Lobby Protruding Object The counter is a protruding object. See Above Adjust the counter so that it is no longer a protruding object. See Recommendation Adjust the counter 450 Notes : Counter Protrudes 15 Into the Path of Travel. ADA 902, 307.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449057 0 Counters 2nd Floor Fingerprint Counter in Lobby Clear Floor Space Width The clear floor space width at the counter is not compliant. 23.00 inches Provide compliant clear floor space at the counter. At least 30.00 inches -7.00 inches 1260 Notes : Counter Protrudes 15 Into the Path of Travel. ADA 904.3, 305, CA 11B-904.4,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449058 0 Counters 2nd Floor Fingerprint Counter in Lobby Knee Clearance Depth The knee clearance depth provided is not compliant. 15.00 inches Provide compliant knee clearance depth at the counter for a forward approach. At least 19.00 inches -4.00 inches 1260 Notes : Counter Protrudes 15 Into the Path of Travel. ADA 306.3, CA 11B-306.3,904.4, 904.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446416 0 Counters 1st Floor Reception Counter in Booking Area Counter Height The height of the counter or desk does not comply with height requirements. 43.50 inches Provide a portion of counter at the compliant height. 28.00 - 34.00 inches 9.50 inches Provide compliant counter 3500 ADA 902, 904, CA 11B-904.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446417 0 Counters 1st Floor Reception Counter in Booking Area Clear Floor Space No clear floor space is provided at the counter. Not Found Provide compliant clear floor space at the counter. See Recommendation 1260 ADA 904.3, CA 11B-904.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449105 0 Counters 1st Floor Records Counter in Lobby Counter Height The height of the counter or desk does not comply with height requirements. 40.75 inches Provide a portion of counter at the compliant height. 28.00 - 34.00 inches 6.75 inches Provide compliant counter 3500 ADA 902, 904, CA 11B-904.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445256 0 Signage 2nd Floor Administration Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445406 0 Signage 2nd Floor Administrative Analyst Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445458 0 Signage 2nd Floor Administrative Assistant Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445269 0 Signage 2nd Floor Administrative Captain Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445404 0 Signage 2nd Floor Administrative Lieutenant Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445225 0 Signage 2nd Floor Administrative Sergeant Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446404 0 Signage 1st Floor Booking Area - Exterior Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446402 0 Signage 1st Floor Booking Area - Interior Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445348 0 Signage 2nd Floor Chief of Police Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445322 0 Signage 2nd Floor Communications Manager Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445258 0 Signage 2nd Floor Conference Room Next to Interview Room Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445465 0 Signage 1st Floor Crime Lab Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445375 0 Signage 1st Floor Crime Lab Office Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446428 0 Signage 1st Floor Data Entry Next to Holding Cells Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445215 0 Signage 2nd Floor Day Watch Commander Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445500 0 Signage 1st Floor Digital Evidence Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449059 0 Signage Exterior Directional Signage from the Public Right of Way to Main Entrance - Left Directional or Information Signage There is no directional signage. None Found Install directional signage to each accessible element or room. See Recommendation Install signage 158 ADA 703, 216, 216.3, CA 11B-216.3, 703.5,703.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449043 0 Signage Exterior Directional Signage from the Public Right of Way to Main Entrance - Right Directional or Information Signage There is no directional signage. None Found Install directional signage to each accessible element or room. See Recommendation Install signage 158 ADA 703, 216, 216.3, CA 11B-216.3, 703.5,703.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445268 0 Signage 2nd Floor Door Between Chief of Police & Administration Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446544 0 Signage 1st Floor Doorway Across from Interview Room 1 in Lobby Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446450 0 Signage 1st Floor Doorway Next to Administrative Assistant Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448994 0 Signage 2nd Floor Doorway Next to Interview Room 2 in Lobby Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445275 0 Signage 2nd Floor Field Supervisor Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445201 0 Signage 2nd Floor Interview Room Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446381 0 Signage 2nd Floor Interview Room 1 in Lobby Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446501 0 Signage 2nd Floor Interview Room 2 in Lobby Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445398 0 Signage 2nd Floor Interview Room Next to Investigations Lieutenant Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446392 0 Signage 1st Floor Intoxilyzer Room Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445466 0 Signage 2nd Floor Investigations Lieutenant Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445354 0 Signage 1st Floor Lecture Room Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446444 0 Signage 1st Floor Lecture Room Exterior Entrance Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445407 0 Signage 1st Floor Locker Room Entrance - Exterior Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445227 0 Signage 1st Floor Locker Room Entrance - Interior Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446449 0 Signage 1st Floor Locker Room Entrance Across Report Writing - Exterior Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446380 0 Signage 1st Floor Locker Room Entrance Across Report Writing - Interior Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446567 0 Signage 2nd Floor Main Entrance Accessible Element/Entrance Signage There is no room signage. None Found Install accessible room signage. See Recommendation Install signage 158 ADA 216.2, 216.6, CA 11B-216.2,216.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445270 0 Signage 2nd Floor Neighborhood Outreach Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445267 0 Signage 2nd Floor Night Watch Commander Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446318 0 Signage 1st Floor North Entrance Next to Rain Gear Accessible Element/Entrance Signage There is no room signage. None Found Install accessible room signage. See Recommendation Install signage 158 ADA 216.2, 216.6, CA 11B-216.2,216.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445321 0 Signage 2nd Floor Offices Next to Investigations Lieutenant Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445226 0 Signage 2nd Floor Open Doorway Next to Records Supervisor Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445501 0 Signage 2nd Floor Operations Captain Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445228 0 Signage 1st Floor Physical Evidence Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445293 0 Signage 2nd Floor Programs Office Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445190 0 Signage 1st Floor Property Office Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449106 0 Signage 2nd Floor Records Area Next to Lobby Counter Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445432 0 Signage 2nd Floor Records Offices Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445405 0 Signage 2nd Floor Records Supervisor Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445347 0 Signage 1st Floor Report Writing Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445248 0 Signage 1st Floor Shower Room Next to Locker Room Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445294 0 Signage 1st Floor Special Enforcement Team Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446365 0 Signage 1st Floor Staff Entrance Across from Workout Room Exterior Entrance Accessible Element/Entrance Signage There is no room signage. None Found Install accessible room signage. See Recommendation Install signage 158 ADA 216.2, 216.6, CA 11B-216.2,216.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445237 0 Signage 2nd Floor Staff Lounge Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446427 0 Signage 1st Floor Tactical Stoage Hallway Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445353 0 Signage 1st Floor Training Room Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445202 0 Signage 1st Floor Training Room - Exterior Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446302 0 Signage 1st Floor Water Fountain in Hallway Next to Lecture Room Accessible Element/Entrance Signage There is no room signage. None Found Install accessible room signage. See Recommendation Install signage 158 Notes : Not Operational at Time of Inspection. ADA 216.2, 216.6, CA 11B-216.2,216.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448993 0 Signage 1st Floor West Entrance Next to Special Enforcement Team Accessible Element/Entrance Signage There is no room signage. None Found Install accessible room signage. See Recommendation Install signage 158 ADA 216.2, 216.6, CA 11B-216.2,216.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446488 0 Signage 1st Floor Workout Room Exterior Entrance Room Identification There is no compliant room identification signage provided. None Found Install compliant room identification signage. See Recommendation Install signage 158 ADA 703, 216, 216.2, CA 11B-216.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449039 0 Public Telephones Exterior Payphone Next to Main Entrance Phone Cord Length The cord length from the public telephone to the handset is not compliant. 28.00 inches Provide a cord with a compliant length from the telephone to the handset. At least 29.00 inches -1.00 inches Provide new accessible telephones 1313 ADA 704, 704.2, CA 11B-704.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449040 0 Public Telephones Exterior Payphone Next to Main Entrance Highest Operable Parts The highest operable part of the public telephone is not compliant. 53.00 inches Adjust the highest operable part of the telephone to a compliant height. 15.00 - 48.00 inches 5.00 inches Lower public telephones 458 ADA 309, 205, 704, 309.3, 704.2, CA 11B-309,704.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449041 0 Public Telephones Exterior Payphone Next to Main Entrance Volume Controls Signage There is no signage for the volume controls. Not Found Provide compliant signage for the volume controls. See Recommendation ADA 703.7, CA 11B-703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446394 0 Restrooms 1st Floor Holding Cell - Left Lavatory Pedestal Pedestal sink does not allow a forward approach. Not Compliant Provide compliant lavatory. See Recommendation 962 ADA 213, 606, 606.2, 306.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446395 0 Restrooms 1st Floor Holding Cell - Left Lavatory Lavatory Apron Height The apron height under the lavatory is less than the required minimum height. 1.00 inches Raise or replace the lavatory to provide the minimum required apron height. At least 29.00 inches -28.00 inches Provide compliant lavatory 2500 ADA 213, 606, 306.3, CA 11B-306.3,606.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446396 0 Restrooms 1st Floor Holding Cell - Left Lavatory Lavatory Distance From Wall/Fixture The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. 15.37 inches on center Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. At least 18.00 inches on center -2.63 inches Install new sink, faucet and handles 2500 CA 11B- 606.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446397 0 Restrooms 1st Floor Holding Cell - Left Lavatory Lavatory Clear Floor Space Width There is not sufficient clear floor space provided to allow an accessible forward approach. 1.00 inches Relocate the lavatory to provide clear floor space. At least 30.00 inches -29.00 inches Install new sink, faucet and handles 2261 ADA 213, 606, 606.2, 305.3, CA 11B-606.2,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446398 0 Restrooms 1st Floor Holding Cell - Left Lavatory Lavatory Clear Floor Space Length There is not sufficient clear floor space provided to allow an accessible forward approach. 1.00 inches Relocate the lavatory to provide clear floor space. At least 48.00 inches -47.00 inches Install new sink, faucet and handles 2261 ADA 213, 606, 606.2, 305.3, CA 11B-606.2,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446458 0 Restrooms 1st Floor Holding Cell - Left Toilet Distance From Wall The distance from the center of the toilet to the nearest side wall does not meet the required distance. 15.37 inches on center Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. 17.00 - 18.00 inches -1.63 inches Relocate fixture 2500 ADA 603, 604.2, CA 11B-604.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446459 0 Restrooms 1st Floor Holding Cell - Left Toilet Seat Height The height of the toilet seat is not at the required height. 15.37 inches Adjust or modify the toilet so the seat height is at the required accessible height. 17.00 - 19.00 inches -1.63 inches Modify fixture 1707 ADA 603, 604.4, CA 11B-604.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446461 0 Restrooms 1st Floor Holding Cell - Left Toilet Flush Control - Wide Side The flush control on the toilet is not on the wide (approach) side of the toilet. Wrong Side of Toilet Relocate the flush control so it is on the wide (approach) side of the toilet area. Flush controls shall be hand-operated or automatic mechanisms. See Recommendation Relocate flush valve 127 ADA 603, 604.6, CA 11B-604.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446462 0 Restrooms 1st Floor Holding Cell - Left Distance from Front Edge of Toilet to Front of Grab Bar The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. 23.75 inches Install or relocate the side grab bar so that the distance from the front edge of the toilet to the front edge of the side grab bar meets the required minimum distance. At least 24.00 inches -0.25 inches Provide compliant grab bar 267 CA 11B- 604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446463 0 Restrooms 1st Floor Holding Cell - Left Located Behind Front of Seat The paper dispenser is located behind the front of toilet seat. See Above Provide a compliant toilet paper dispenser. See Recommendation Provide dispenser 230 ADA 604.7, CA 11B-604.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446393 0 Restrooms 1st Floor Holding Cell - Left Door Privacy Lock and Occupied Indicator The restroom door does not provide a compliant privacy lock with occupancy indicator. None Found Install a compliant privacy lock with occupancy indicator to the door. See Recommendation Replace existing lock set with lever handled lock set 804 ADA 213, 213.2, CA 11B-213.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446453 0 Restrooms 1st Floor Holding Cell - Right Toilet Distance From Wall The distance from the center of the toilet to the nearest side wall does not meet the required distance. 15.37 inches on center Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. 17.00 - 18.00 inches -1.63 inches Relocate fixture 2500 ADA 603, 604.2, CA 11B-604.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446454 0 Restrooms 1st Floor Holding Cell - Right Toilet Seat Height The height of the toilet seat is not at the required height. 15.50 inches Adjust or modify the toilet so the seat height is at the required accessible height. 17.00 - 19.00 inches -1.50 inches Modify fixture 1707 ADA 603, 604.4, CA 11B-604.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446456 0 Restrooms 1st Floor Holding Cell - Right Toilet Flush Control - Wide Side The flush control on the toilet is not on the wide (approach) side of the toilet. Wrong Side of Toilet Relocate the flush control so it is on the wide (approach) side of the toilet area. Flush controls shall be hand-operated or automatic mechanisms. See Recommendation Relocate flush valve 127 ADA 603, 604.6, CA 11B-604.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446457 0 Restrooms 1st Floor Holding Cell - Right Distance from Front Edge of Toilet to Front of Grab Bar The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. 23.50 inches Install or relocate the side grab bar so that the distance from the front edge of the toilet to the front edge of the side grab bar meets the required minimum distance. At least 24.00 inches -0.50 inches Provide compliant grab bar 267 CA 11B- 604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446539 0 Restrooms 1st Floor Holding Cell - Right Lavatory Pedestal Pedestal sink does not allow a forward approach. Not Compliant Provide compliant lavatory. See Recommendation 962 ADA 213, 606, 606.2, 306.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446540 0 Restrooms 1st Floor Holding Cell - Right Lavatory Lavatory Apron Height The apron height under the lavatory is less than the required minimum height. 1.00 inches Raise or replace the lavatory to provide the minimum required apron height. At least 29.00 inches -28.00 inches Provide compliant lavatory 2500 ADA 213, 606, 306.3, CA 11B-306.3,606.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446541 0 Restrooms 1st Floor Holding Cell - Right Lavatory Lavatory Distance From Wall/Fixture The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. 15.37 inches on center Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. At least 18.00 inches on center -2.63 inches Install new sink, faucet and handles 2500 CA 11B- 606.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446542 0 Restrooms 1st Floor Holding Cell - Right Lavatory Lavatory Clear Floor Space Width There is not sufficient clear floor space provided to allow an accessible forward approach. 1.00 inches Relocate the lavatory to provide clear floor space. At least 30.00 inches -29.00 inches Install new sink, faucet and handles 2261 ADA 213, 606, 606.2, 305.3, CA 11B-606.2,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446543 0 Restrooms 1st Floor Holding Cell - Right Lavatory Lavatory Clear Floor Space Length There is not sufficient clear floor space provided to allow an accessible forward approach. 1.00 inches Relocate the lavatory to provide clear floor space. At least 48.00 inches -47.00 inches Install new sink, faucet and handles 2261 ADA 213, 606, 606.2, 305.3, CA 11B-606.2,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446452 0 Restrooms 1st Floor Holding Cell - Right Toilet Paper Dispenser There is no toilet paper dispenser provided on the narrow side wall. None Found Install a compliant toilet paper dispenser. See Recommendation Provide compliant dispenser 277 ADA 603, 604.7, CA 11B-604.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446538 0 Restrooms 1st Floor Holding Cell - Right Door Privacy Lock and Occupied Indicator The restroom door does not provide a compliant privacy lock with occupancy indicator. None Found Install a compliant privacy lock with occupancy indicator to the door. See Recommendation Replace existing lock set with lever handled lock set 804 ADA 213, 213.2, CA 11B-213.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445364 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 32.12 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -9.88 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445365 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Toilet Clear Floor Space There is less than the required minimum space in front of the toilet. 47.50 inches Create the required minimum clear space in front of the toilet. At least 48.00 inches -0.50 inches Modify space 3500 ADA 603, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445366 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Distance from Back Wall to Front of Grab Bar The distance from the back wall to the front of the grab bar is less than required. 50.00 inches Install or move the grab bar to create the required distance from the back wall to the front of the grab bar. At least 54.00 inches -4.00 inches Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5,609 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445367 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Distance from Front Edge of Toilet to Front of Grab Bar The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. 22.50 inches Install or relocate the side grab bar so that the distance from the front edge of the toilet to the front edge of the side grab bar meets the required minimum distance. At least 24.00 inches -1.50 inches Provide compliant grab bar 267 CA 11B- 604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445368 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Rear Grab Bar Length The length of the rear grab bar is less than required. 30.00 inches Replace the rear grab bar with a compliant grab bar. At least 36.00 inches -6.00 inches Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445369 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Rear Grab Bar Location Rear grab bar location is not compliant. Not Compliant Remount the rear grab bar to a compliant location. See Recommendation Provide a compliant back grab bar. 267 ADA 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445370 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Toilet Paper Dispenser Distance From Seat The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. 11.00 inches Remount the toilet paper dispenser at a compliant height and location. 7.00 - 9.00 inches 2.00 inches Provide compliant dispenser 277 ADA 603, 604.7, CA 11B-604.7,309.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445371 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Toilet Paper Dispenser Interferes with Grab Bar The toilet paper dispenser interferes with the use of the grab bar. Interferes Relocate the toilet paper dispenser so it does not interfere with the use of a grab bar. Toilet paper dispensers must allow continuous paper flow. See Recommendation Provide compliant dispenser 277 ADA 603, 609.3, CA 11B-309.4,609.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445372 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Toilet Paper Dispenser Above Grab Bar The toilet paper dispenser is located above the provided grab bar. Above Grab Bar Remount the dispenser below the grab bar at 19" minimum. Relocate Dispenser Provide compliant dispenser 277 ADA 603, CA 11B-604.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445480 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Mirror Bottom Edge Height The bottom edge of the reflective surface of the mirror is not at the correct height. 40.25 inches Lower the mirror so the bottom edge of the reflective surface is no higher than recommended above the finished floor. Up to 40.00 inches 0.25 inches Lower mirror 300 ADA 603, 213, 603.3, CA 11B-603.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445481 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Door Sign - Male Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445479 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Lavatory Lavatory - Supply Lines Wrapping The supply lines under the lavatory do not provide protection against contact. Not Wrapped Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap supply lines 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445478 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 49.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 9.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445477 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Soap Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 45.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 5.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445482 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Wall Sign Wall Signage There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. None Found Provide compliant signage on latch side of door. See Recommendation Install signage 158 ADA 703, 216, 216.8, CA 11B-216.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445361 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Seat Cover Dispenser Height The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. 42.37 inches Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Up to 40.00 inches 2.37 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445362 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Seat Cover Dispenser Seat cover dispenser interferes with use of grab bar. Interferes Move the seat cover dispenser so it does not interfere with the use of the grab bars. See Recommendation 277 ADA 609.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445363 0 Restrooms 2nd Floor Mens Restroom Next to Investigations Lieutenant Shelf Height The shelf is mounted at an incorrect height. 51.75 inches Mount the shelf at the recommended height. 40.00 - 48.00 inches 3.75 inches Provide compliant dispenser 277 ADA 603, 603.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445219 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Lavatory Lavatory Apron Height The apron height under the lavatory is less than the required minimum height. 26.75 inches Raise or replace the lavatory to provide the minimum required apron height. At least 29.00 inches -2.25 inches Provide compliant lavatory 2500 ADA 213, 606, 306.3, CA 11B-306.3,606.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445220 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Lavatory Lavatory Knee Clearance The knee clearance space under the lavatory is less than the required minimum height. 24.12 inches Raise or replace the lavatory to provide the minimum required knee clearance. At least 27.00 inches -2.88 inches Provide compliant lavatory 1286 ADA 213, 606, 606.2, 306.3, CA 11B-606.2,306.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445221 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Lavatory Lavatory Clear Floor Space Length There is not sufficient clear floor space provided to allow an accessible forward approach. 35.00 inches Relocate the lavatory to provide clear floor space. At least 48.00 inches -13.00 inches Install new sink, faucet and handles 2261 ADA 213, 606, 606.2, 305.3, CA 11B-606.2,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445218 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 49.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 9.00 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445222 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Urinal Rim Height The height of the urinal rim in the restroom is not compliant. 23.50 inches Lower the urinal designated to be accessible in the restroom so that the rim height is compliant. Up to 17.00 inches 6.50 inches Lower urinal 1397 ADA 605, 605.2, CA 11B-605.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445223 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Door Sign - Male Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445224 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Wall Sign Wall Signage There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. None Found Provide compliant signage on latch side of door. See Recommendation Install signage 158 ADA 703, 216, 216.8, CA 11B-216.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445283 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Toilet Seat Height The height of the toilet seat is not at the required height. 16.50 inches Adjust or modify the toilet so the seat height is at the required accessible height. 17.00 - 19.00 inches -0.50 inches Modify fixture 1707 ADA 603, 604.4, CA 11B-604.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445284 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 18.50 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -23.50 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445285 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Toilet Clear Floor Space There is less than the required minimum space in front of the toilet. 29.25 inches Create the required minimum clear space in front of the toilet. At least 48.00 inches -18.75 inches Modify space 3500 ADA 603, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445286 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Compartment Door Handle The door to the compartment does not have an accessible handle on both sides. Not on both sides. Provide an accessible handle mounted on the door of the compartment near the latch. See Recommendation Install accessible handle on stall door 250 ADA 404, 213, 604, 604.8, 604.8, CA 11B-404.2,604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445287 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Compartment Door Width The clear opening width of the doorway to the compartment is less than required. 22.50 inches Widen the doorway to provide a compliant clear opening width when the door is open 90 degrees. At least 32.00 inches -9.50 inches Install compartment door with accessible hardware 4000 ADA 404, 404.2, 604.8, CA 11B-604.8,404.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445288 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Toilet Compartment Door The compartment door is located in front of the water closet. Not Located Reconfigure the toilet compartment to provide a compliant door that is located adjacent to the water closet. See Recommendation 4000 ADA 604.8, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445289 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Compartment Door Swings In The door to the compartment swings inward into the minimum required compartment area. Swings In Modify the swing of the door so that it does not swing into the minimum required compartment area. See Recommendation Modify door swing 269 ADA 603, 604.8, 304.4, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445290 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Door Handle The inside handle is not located near the latch. None Found Adjust the inside handle so that it is located near the latch. See Recommendation Adjust handle 129 ADA 404, 213, 604, 604.8, CA 11B-404.2,604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445291 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Front Approach Latch Side Clearance There is less than the required latch side clearance on the pull side of the door. 6.50 inches Provide required latch side clearance on the pull side of the door. At least 18.00 inches -11.50 inches Provide clearance 2200 ADA 404, 604.8, 604.8, 404.2, CA 11B-604.8,404 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445292 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Coat Hook Height The coat hook is not mounted at the correct height. 66.00 inches Mount the coat hook at the recommended height. 15.00 - 48.00 inches 18.00 inches Move coat hook 50 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445216 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Circular Turning Space Diameter There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. 54.25 inches Modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. At least 60.00 inches -5.75 inches Install single-use toilet room 14000 ADA 603, 304, 304.3, 603.2, 304.3, 603.2, CA 11B-304.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445217 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Distance from Door Edge to Nearest Fixture The entrance door swings into the turning space within the restroom. 29.00 inches Reverse the door swing, or modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. At least 48.00 inches -19.00 inches Provide clear floor space 8200 ADA 304, 603.2, 305.3, 603.2, CA 11B-603.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445276 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Seat Cover Dispenser Behind Toilet The location of the seat cover dispenser does not provide sufficient clear floor space. Not Accessible Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. See Recommendation Provide compliant dispenser 277 ADA 304, 309.2, 305.1, CA 11B-603.5,309.2,305.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445277 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Toilet Paper Dispenser There is no toilet paper dispenser provided on the narrow side wall. None Found Install a compliant toilet paper dispenser. See Recommendation Provide compliant dispenser 277 ADA 603, 604.7, CA 11B-604.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445278 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Clear Space in Front of Compartment The latch side approach to the compartment designated to be accessible in the restroom is not wide enough. 35.00 inches Provide a latch-side approach to the compartment designated to be accessible with a clear, unobstructed access width. At least 44.00 inches -9.00 inches Add new toilet partition with 36 inch door 4000 ADA 603, 604.8, CA 11B-604.8,604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445279 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Toilet Compartment Width There is insufficient clear floor space in the compartment. 35.75 inches Modify or replace the compartment to provide adequate clear floor space. At least 60.00 inches -24.25 inches Install accessible stall 4000 ADA 603, 213, 604, 604.8, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445280 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Toilet Compartment Length There is insufficient clear floor space in the compartment. 55.25 inches Modify or replace the compartment to provide adequate clear floor space. At least 56.00 inches -0.75 inches Install accessible stall 4000 ADA 603, 213, 604, 604.8, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445281 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Seat Cover Dispenser Height The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. 54.75 inches Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Up to 40.00 inches 14.75 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445282 0 Restrooms 1st Floor Mens Restroom Next to Locker Room Grab Bars There are no grab bars. None Found Install the required grab bars in the toilet compartment. See Recommendation Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445410 0 Restrooms 2nd Floor Mens Restroom Next to Records Lavatory Lavatory Apron Height The apron height under the lavatory is less than the required minimum height. 28.12 inches Raise or replace the lavatory to provide the minimum required apron height. At least 29.00 inches -0.88 inches Provide compliant lavatory 2500 ADA 213, 606, 306.3, CA 11B-306.3,606.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445411 0 Restrooms 2nd Floor Mens Restroom Next to Records Lavatory Lavatory Knee Clearance The knee clearance space under the lavatory is less than the required minimum height. 24.50 inches Raise or replace the lavatory to provide the minimum required knee clearance. At least 27.00 inches -2.50 inches Provide compliant lavatory 1286 ADA 213, 606, 606.2, 306.3, CA 11B-606.2,306.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445409 0 Restrooms 2nd Floor Mens Restroom Next to Records Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 63.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 23.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445415 0 Restrooms 2nd Floor Mens Restroom Next to Records Mirror Bottom Edge Height The bottom edge of the reflective surface of the mirror is not at the correct height. 48.50 inches Lower the mirror so the bottom edge of the reflective surface is no higher than recommended above the finished floor. Up to 40.00 inches 8.50 inches Lower mirror 300 ADA 603, 213, 603.3, CA 11B-603.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445416 0 Restrooms 2nd Floor Mens Restroom Next to Records Door Sign - Male Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445412 0 Restrooms 2nd Floor Mens Restroom Next to Records Lavatory Lavatory Distance From Wall/Fixture The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. 16.25 inches on center Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. At least 18.00 inches on center -1.75 inches Install new sink, faucet and handles 2500 CA 11B- 606.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445417 0 Restrooms 2nd Floor Mens Restroom Next to Records Wall Sign Wall Signage There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. None Found Provide compliant signage on latch side of door. See Recommendation Install signage 158 ADA 703, 216, 216.8, CA 11B-216.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445449 0 Restrooms 2nd Floor Mens Restroom Next to Records Toilet Distance From Wall The distance from the center of the toilet to the nearest side wall does not meet the required distance. 14.50 inches on center Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. 17.00 - 18.00 inches -2.50 inches Relocate fixture 2500 ADA 603, 604.2, CA 11B-604.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445450 0 Restrooms 2nd Floor Mens Restroom Next to Records Toilet Seat Height The height of the toilet seat is not at the required height. 16.50 inches Adjust or modify the toilet so the seat height is at the required accessible height. 17.00 - 19.00 inches -0.50 inches Modify fixture 1707 ADA 603, 604.4, CA 11B-604.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445451 0 Restrooms 2nd Floor Mens Restroom Next to Records Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 19.62 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -22.38 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445452 0 Restrooms 2nd Floor Mens Restroom Next to Records Toilet Clear Floor Space There is less than the required minimum space in front of the toilet. 40.25 inches Create the required minimum clear space in front of the toilet. At least 48.00 inches -7.75 inches Modify space 3500 ADA 603, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445408 0 Restrooms 2nd Floor Mens Restroom Next to Records Circular Turning Space Diameter There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. 41.25 inches Modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. At least 60.00 inches -18.75 inches Install single-use toilet room 14000 Notes : Toilet Obstructs Turning Space Diameter. ADA 603, 304, 304.3, 603.2, 304.3, 603.2, CA 11B-304.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445447 0 Restrooms 2nd Floor Mens Restroom Next to Records Seat Cover Dispenser Height The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. 55.50 inches Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Up to 40.00 inches 15.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445448 0 Restrooms 2nd Floor Mens Restroom Next to Records Grab Bars There are no grab bars. None Found Install the required grab bars in the toilet compartment. See Recommendation Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445239 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Toilet Distance From Wall The distance from the center of the toilet to the nearest side wall does not meet the required distance. 15.12 inches on center Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. 17.00 - 18.00 inches -1.88 inches Relocate fixture 2500 ADA 603, 604.2, CA 11B-604.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445240 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Toilet Seat Height The height of the toilet seat is not at the required height. 16.50 inches Adjust or modify the toilet so the seat height is at the required accessible height. 17.00 - 19.00 inches -0.50 inches Modify fixture 1707 ADA 603, 604.4, CA 11B-604.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445242 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Toilet Flush Control - Wide Side The flush control on the toilet is not on the wide (approach) side of the toilet. Wrong Side of Toilet Relocate the flush control so it is on the wide (approach) side of the toilet area. Flush controls shall be hand-operated or automatic mechanisms. See Recommendation Relocate flush valve 127 ADA 603, 604.6, CA 11B-604.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445243 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 23.62 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -18.38 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445244 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Toilet Clear Floor Space There is less than the required minimum space in front of the toilet. 38.75 inches Create the required minimum clear space in front of the toilet. At least 48.00 inches -9.25 inches Modify space 3500 ADA 603, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445245 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Coat Hook Height The coat hook is not mounted at the correct height. 49.50 inches Mount the coat hook at the recommended height. 15.00 - 48.00 inches 1.50 inches Move coat hook 50 ADA 308, 603.4, 308.1, CA 11B-308,603.4,604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445306 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Door Sign - All Gender Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445302 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Lavatory Lavatory Control Type The faucet controls on the lavatory require tight grasping, pinching, or twisting of the wrist and are not accessible. Not Accessible Install accessible faucet controls on the lavatory. See Recommendation Replace knob faucets with paddle faucets 392 ADA 213, 606, 309.4, CA 11B-309.4,213,606 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445303 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Lavatory Pedestal Pedestal sink does not allow a forward approach. Not Compliant Provide compliant lavatory. See Recommendation 962 ADA 213, 606, 606.2, 306.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445304 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Lavatory Lavatory Distance From Wall/Fixture The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. 17.75 inches on center Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. At least 18.00 inches on center -0.25 inches Install new sink, faucet and handles 2500 CA 11B- 606.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445305 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Lavatory Lavatory - Supply Lines Wrapping The supply lines under the lavatory do not provide protection against contact. Not Wrapped Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap supply lines 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445301 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 50.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 10.00 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445300 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Soap Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 41.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 1.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445307 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Wall Sign Wall Signage There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. None Found Provide compliant signage on latch side of door. See Recommendation Install signage 158 ADA 703, 216, 216.8, CA 11B-216.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445238 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Grab Bars There are no grab bars. None Found Install the required grab bars in the toilet compartment. See Recommendation Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445298 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Door Privacy Lock and Occupied Indicator The restroom door does not provide a compliant privacy lock with occupancy indicator. None Found Install a compliant privacy lock with occupancy indicator to the door. See Recommendation Replace existing lock set with lever handled lock set 804 Notes : Toilet Obstructs Turning Space Diameter. ADA 213, 213.2, CA 11B-213.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445299 0 Restrooms 2nd Floor Unisex Restroom in Chief of Police Office Circular Turning Space Diameter There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. 44.75 inches Modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. At least 60.00 inches -15.25 inches Install single-use toilet room 14000 Notes : Toilet Obstructs Turning Space Diameter. ADA 603, 304, 304.3, 603.2, 304.3, 603.2, CA 11B-304.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448997 0 Restrooms 2nd Floor Unisex Restroom in Lobby Toilet Distance From Wall The distance from the center of the toilet to the nearest side wall does not meet the required distance. 18.50 inches on center Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. 17.00 - 18.00 inches 0.50 inches Relocate fixture 2500 ADA 603, 604.2, CA 11B-604.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448998 0 Restrooms 2nd Floor Unisex Restroom in Lobby Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 34.00 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -8.00 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448999 0 Restrooms 2nd Floor Unisex Restroom in Lobby Rear Grab Bar Length The length of the rear grab bar is less than required. 30.00 inches Replace the rear grab bar with a compliant grab bar. At least 36.00 inches -6.00 inches Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449000 0 Restrooms 2nd Floor Unisex Restroom in Lobby Rear Grab Bar Location Rear grab bar location is not compliant. Not Compliant Remount the rear grab bar to a compliant location. See Recommendation Provide a compliant back grab bar. 267 ADA 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449002 0 Restrooms 2nd Floor Unisex Restroom in Lobby Toilet Paper Dispenser Distance From Seat The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. 5.00 inches Remount the toilet paper dispenser at a compliant height and location. 7.00 - 9.00 inches -2.00 inches Provide compliant dispenser 277 ADA 603, 604.7, CA 11B-604.7,309.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449065 0 Restrooms 2nd Floor Unisex Restroom in Lobby Door Sign - All Gender Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449064 0 Restrooms 2nd Floor Unisex Restroom in Lobby Lavatory Lavatory - Supply Lines Wrapping The supply lines under the lavatory do not provide protection against contact. Not Wrapped Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap supply lines 149 Notes : Supply Lines Not Completely Wrapped. ADA 213, 606, 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449062 0 Restrooms 2nd Floor Unisex Restroom in Lobby Soap Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 41.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 1.00 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449066 0 Restrooms 2nd Floor Unisex Restroom in Lobby Wall Sign Clear Floor Space/Door Swing Clear floor space of at least 18"x18" is not centered at the signage and/or is within the swing of the door. Not Compliant Provide at least 18"x18" of clear floor space centered at the signage. Make sure it is not located within the door swing. See Recommendation ADA 703.4, CA 11B-703.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448995 0 Restrooms 2nd Floor Unisex Restroom in Lobby Seat Cover Dispenser Height The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. 43.00 inches Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Up to 40.00 inches 3.00 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448996 0 Restrooms 2nd Floor Unisex Restroom in Lobby Seat Cover Dispenser Seat cover dispenser interferes with use of grab bar. Interferes Move the seat cover dispenser so it does not interfere with the use of the grab bars. See Recommendation 277 ADA 609.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 449061 0 Restrooms 2nd Floor Unisex Restroom in Lobby Door Privacy Lock and Occupied Indicator The restroom door does not provide a compliant privacy lock with occupancy indicator. None Found Install a compliant privacy lock with occupancy indicator to the door. See Recommendation Replace existing lock set with lever handled lock set 804 ADA 213, 213.2, CA 11B-213.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446423 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Toilet Distance From Wall The distance from the center of the toilet to the nearest side wall does not meet the required distance. 16.37 inches on center Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. 17.00 - 18.00 inches -0.63 inches Relocate fixture 2500 ADA 603, 604.2, CA 11B-604.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446424 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Toilet Seat Height The height of the toilet seat is not at the required height. 15.75 inches Adjust or modify the toilet so the seat height is at the required accessible height. 17.00 - 19.00 inches -1.25 inches Modify fixture 1707 ADA 603, 604.4, CA 11B-604.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446425 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 17.75 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -24.25 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446426 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Toilet Clear Floor Space There is less than the required minimum space in front of the toilet. 39.50 inches Create the required minimum clear space in front of the toilet. At least 48.00 inches -8.50 inches Modify space 3500 ADA 603, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446478 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Door Sign - All Gender Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446472 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Lavatory Lavatory Apron Height The apron height under the lavatory is less than the required minimum height. 27.25 inches Raise or replace the lavatory to provide the minimum required apron height. At least 29.00 inches -1.75 inches Provide compliant lavatory 2500 ADA 213, 606, 306.3, CA 11B-306.3,606.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446473 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Lavatory Lavatory Knee Clearance The knee clearance space under the lavatory is less than the required minimum height. 24.75 inches Raise or replace the lavatory to provide the minimum required knee clearance. At least 27.00 inches -2.25 inches Provide compliant lavatory 1286 ADA 213, 606, 606.2, 306.3, CA 11B-606.2,306.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446474 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Lavatory Lavatory Distance From Wall/Fixture The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. 15.62 inches on center Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. At least 18.00 inches on center -2.38 inches Install new sink, faucet and handles 2500 CA 11B- 606.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446475 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Lavatory Lavatory Clear Floor Space Length There is not sufficient clear floor space provided to allow an accessible forward approach. 21.25 inches Relocate the lavatory to provide clear floor space. At least 48.00 inches -26.75 inches Install new sink, faucet and handles 2261 ADA 213, 606, 606.2, 305.3, CA 11B-606.2,305 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446477 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Lavatory Lavatory - Supply Lines Wrapping The supply lines under the lavatory do not provide protection against contact. Not Wrapped Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap supply lines 149 ADA 213, 606, 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446470 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 58.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 18.00 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446471 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Soap Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 50.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 10.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446479 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Wall Sign Wall Signage There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. None Found Provide compliant signage on latch side of door. See Recommendation Install signage 158 ADA 703, 216, 216.8, CA 11B-216.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446418 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Seat Cover Dispenser Behind Toilet The location of the seat cover dispenser does not provide sufficient clear floor space. Not Accessible Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. See Recommendation Provide compliant dispenser 277 ADA 304, 309.2, 305.1, CA 11B-603.5,309.2,305.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446419 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Toilet Paper Dispenser There is no toilet paper dispenser provided on the narrow side wall. None Found Install a compliant toilet paper dispenser. See Recommendation Provide compliant dispenser 277 ADA 603, 604.7, CA 11B-604.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446420 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Toilet Clear Floor Space Width The clearance around the water closet measured perpendicular from the side wall is not compliant. 34.12 inches Provide a compliant clearance around the water closet measured perpendicular from the rear wall. At least 60.00 inches -25.88 inches Modify fixture 1707 ADA 603, 502.4, 604.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446421 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Seat Cover Dispenser Height The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. 58.25 inches Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Up to 40.00 inches 18.25 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446422 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Grab Bars There are no grab bars. None Found Install the required grab bars in the toilet compartment. See Recommendation Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446468 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Door Privacy Lock and Occupied Indicator The restroom door does not provide a compliant privacy lock with occupancy indicator. None Found Install a compliant privacy lock with occupancy indicator to the door. See Recommendation Replace existing lock set with lever handled lock set 804 Notes : Lavatory Toilet Obstructs Turning Space Diameter. ADA 213, 213.2, CA 11B-213.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446469 0 Restrooms 1st Floor Unisex Restroom Next to Holding Cells Circular Turning Space Diameter There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. 21.50 inches Modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. At least 60.00 inches -38.50 inches Install single-use toilet room 14000 Notes : Lavatory Toilet Obstructs Turning Space Diameter. ADA 603, 304, 304.3, 603.2, 304.3, 603.2, CA 11B-304.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445312 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 31.75 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -10.25 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445313 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Distance from Back Wall to Front of Grab Bar The distance from the back wall to the front of the grab bar is less than required. 53.50 inches Install or move the grab bar to create the required distance from the back wall to the front of the grab bar. At least 54.00 inches -0.50 inches Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5,609 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445314 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Side Grab Bar Height The height of the side grab bar is not at the correct height. 32.62 inches Remount the grab bar so it is at the correct height. 33.00 - 36.00 inches -0.38 inches Relocate compliant grab bars and patch 500 ADA 603, 609, 609.4, CA 11B-609.4,604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445315 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Rear Grab Bar Length The length of the rear grab bar is less than required. 30.00 inches Replace the rear grab bar with a compliant grab bar. At least 36.00 inches -6.00 inches Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445316 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Rear Grab Bar Location Rear grab bar location is not compliant. Not Compliant Remount the rear grab bar to a compliant location. See Recommendation Provide a compliant back grab bar. 267 ADA 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445318 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Toilet Paper Dispenser Distance From Seat The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. 16.00 inches Remount the toilet paper dispenser at a compliant height and location. 7.00 - 9.00 inches 7.00 inches Provide compliant dispenser 277 ADA 603, 604.7, CA 11B-604.7,309.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445319 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Toilet Paper Dispenser Interferes with Grab Bar The toilet paper dispenser interferes with the use of the grab bar. Interferes Relocate the toilet paper dispenser so it does not interfere with the use of a grab bar. Toilet paper dispensers must allow continuous paper flow. See Recommendation Provide compliant dispenser 277 ADA 603, 609.3, CA 11B-309.4,609.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445320 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Toilet Paper Dispenser Above Grab Bar The toilet paper dispenser is located above the provided grab bar. Above Grab Bar Remount the dispenser below the grab bar at 19" minimum. Relocate Dispenser Provide compliant dispenser 277 ADA 603, CA 11B-604.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445422 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Mirror Bottom Edge Height The bottom edge of the reflective surface of the mirror is not at the correct height. 40.50 inches Lower the mirror so the bottom edge of the reflective surface is no higher than recommended above the finished floor. Up to 40.00 inches 0.50 inches Lower mirror 300 ADA 603, 213, 603.3, CA 11B-603.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445423 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Door Sign - Female Door Signage There is no gender use signage on the entrance door. None Found Post gender use signage on the center of the door at the required height. See Recommendation Install signage 158 CA 11B- 216.8,703.7 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445420 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Lavatory Lavatory Control Type The faucet controls on the lavatory require tight grasping, pinching, or twisting of the wrist and are not accessible. Not Accessible Install accessible faucet controls on the lavatory. See Recommendation Replace knob faucets with paddle faucets 392 Notes : Supply Lines Not Completely Wrapped. ADA 213, 606, 309.4, CA 11B-309.4,213,606 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445421 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Lavatory Lavatory - Supply Lines Wrapping The supply lines under the lavatory do not provide protection against contact. Not Wrapped Insulate or otherwise configure pipes under the lavatory to protect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. See Recommendation Wrap supply lines 149 Notes : Supply Lines Not Completely Wrapped. ADA 213, 606, 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445419 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 50.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 10.00 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445418 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Soap Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 44.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 4.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445424 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Wall Sign Wall Signage There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. None Found Provide compliant signage on latch side of door. See Recommendation Install signage 158 ADA 703, 216, 216.8, CA 11B-216.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445310 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Seat Cover Dispenser Height The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. 41.50 inches Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Up to 40.00 inches 1.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445311 0 Restrooms 2nd Floor Womens Restroom Next to Investigations Lieutenant Seat Cover Dispenser Seat cover dispenser interferes with use of grab bar. Interferes Move the seat cover dispenser so it does not interfere with the use of the grab bars. See Recommendation 277 ADA 609.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446357 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Toilet Distance From Wall The distance from the center of the toilet to the nearest side wall does not meet the required distance. 16.00 inches on center Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. 17.00 - 18.00 inches -1.00 inches Relocate fixture 2500 ADA 603, 604.2, CA 11B-604.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446358 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Toilet Seat Height The height of the toilet seat is not at the required height. 16.00 inches Adjust or modify the toilet so the seat height is at the required accessible height. 17.00 - 19.00 inches -1.00 inches Modify fixture 1707 ADA 603, 604.4, CA 11B-604.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446359 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Toilet Minimum Distance From Any fixture The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. 23.12 inches Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. At least 42.00 inches -18.88 inches Relocate fixture 2500 ADA 603, 604, CA 11B-604 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446360 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Toilet Clear Floor Space There is less than the required minimum space in front of the toilet. 25.50 inches Create the required minimum clear space in front of the toilet. At least 48.00 inches -22.50 inches Modify space 3500 ADA 603, CA 11B-604.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446492 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Lavatory Lavatory Control Type The faucet controls on the lavatory require tight grasping, pinching, or twisting of the wrist and are not accessible. Not Accessible Install accessible faucet controls on the lavatory. See Recommendation Replace knob faucets with paddle faucets 392 ADA 213, 606, 309.4, CA 11B-309.4,213,606 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446493 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Lavatory Lavatory Apron Height The apron height under the lavatory is less than the required minimum height. 28.25 inches Raise or replace the lavatory to provide the minimum required apron height. At least 29.00 inches -0.75 inches Provide compliant lavatory 2500 ADA 213, 606, 306.3, CA 11B-306.3,606.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446494 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Lavatory Lavatory Knee Clearance The knee clearance space under the lavatory is less than the required minimum height. 26.75 inches Raise or replace the lavatory to provide the minimum required knee clearance. At least 27.00 inches -0.25 inches Provide compliant lavatory 1286 ADA 213, 606, 606.2, 306.3, CA 11B-606.2,306.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446495 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Lavatory Lavatory Distance From Wall/Fixture The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. 12.50 inches on center Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. At least 18.00 inches on center -5.50 inches Install new sink, faucet and handles 2500 CA 11B- 606.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446491 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Paper Towel Dispenser Height The height of the controls and operating mechanisms for the dispenser is not at the correct height. 50.25 inches Relocate the dispenser to the correct height. Up to 40.00 inches 10.25 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.1, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446498 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Mirror Bottom Edge Height The bottom edge of the reflective surface of the mirror is not at the correct height. 49.00 inches Lower the mirror so the bottom edge of the reflective surface is no higher than recommended above the finished floor. Up to 40.00 inches 9.00 inches Lower mirror 300 ADA 603, 213, 603.3, CA 11B-603.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446500 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Wall Sign Wall Signage There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. None Found Provide compliant signage on latch side of door. See Recommendation Install signage 158 ADA 703, 216, 216.8, CA 11B-216.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446353 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Seat Cover Dispenser Behind Toilet The location of the seat cover dispenser does not provide sufficient clear floor space. Not Accessible Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. See Recommendation Provide compliant dispenser 277 ADA 304, 309.2, 305.1, CA 11B-603.5,309.2,305.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446354 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Toilet Clear Floor Space Length The clearance around the water closet measured perpendicular from the rear wall is not compliant. 53.25 inches Provide a compliant clearance around the water closet measured perpendicular from the rear wall. At least 56.00 inches -2.75 inches Modify fixture 1707 ADA 603, 604.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446355 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Seat Cover Dispenser Height The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. 42.50 inches Relocate the seat cover dispenser to a compliant height, that provides sufficient clear floor space, and does not interfere with use of the grab bars. Up to 40.00 inches 2.50 inches Provide compliant dispenser 277 ADA 309, 205, 308, 606, 308.2, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446356 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Grab Bars There are no grab bars. None Found Install the required grab bars in the toilet compartment. See Recommendation Provide compliant grab bar 267 ADA 603, 609, 604.5, CA 11B-604.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446489 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Circular Turning Space Diameter There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. 36.00 inches Modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. At least 60.00 inches -24.00 inches Install single-use toilet room 14000 ADA 603, 304, 304.3, 603.2, 304.3, 603.2, CA 11B-304.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446490 0 Restrooms 1st Floor Womens Restroom Next to Lecture Room Distance from Door Edge to Nearest Fixture The entrance door swings into the turning space within the restroom. 6.00 inches Reverse the door swing, or modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. At least 48.00 inches -42.00 inches Provide clear floor space 8200 ADA 304, 603.2, 305.3, 603.2, CA 11B-603.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448974 0 Drinking Fountains 2nd Floor Drinking Fountain in Lobby Fountain Type The provided drinking fountain is not a High/Low fountain. Fountain Not Compliant Replace the drinking fountain with a compliant High/Low fountain. See Recommendation Install new high/low fountain 2500 ADA 305, 602, 211.2, CA 11B-211.2,602 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448975 0 Drinking Fountains 2nd Floor Drinking Fountain in Lobby Stream Height The height of the water stream is less than required. 3.50 inches Adjust the flow of the water stream to a compliant height. At least 4.00 inches -0.50 inches Install new high/low fountain 2500 ADA 211, 602, 602.6, CA 11B-211,602 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448976 0 Drinking Fountains 2nd Floor Drinking Fountain in Lobby Fountain Depth Drinking fountain does not provide a required fountain depth. 17.50 inches Install a drinking fountain the meets the required minimum depth. At least 18.00 inches -0.50 inches Install new wall-mounted fountain 2500 ADA 305, 306, 211, 602, CA 11B-602.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448977 0 Drinking Fountains 2nd Floor Drinking Fountain in Lobby Detectable Warnings The drinking fountain is not set entirely in an alcove. None Found Provide compliant wing walls or barrier at the drinking fountain. See Recommendation Install wing walls or relocate object 640 ADA 307.2, 602.1, CA 11B-602.9 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445262 0 Drinking Fountains 2nd Floor Drinking Fountain Next to Programs Office Fountain Type The provided drinking fountain is not a High/Low fountain. Fountain Not Compliant Replace the drinking fountain with a compliant High/Low fountain. See Recommendation Install new high/low fountain 2500 ADA 305, 602, 211.2, CA 11B-211.2,602 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445263 0 Drinking Fountains 2nd Floor Drinking Fountain Next to Programs Office Spout Height The spout outlet height is greater than required. 38.50 inches Provide a spout outlet that does not exceed the required height. Up to 36.00 inches 2.50 inches Install new wall-mounted fountain 627 ADA 211, 602, 602.4, CA 11B-602.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445265 0 Drinking Fountains 2nd Floor Drinking Fountain Next to Programs Office Fountain Depth Drinking fountain does not provide a required fountain depth. 17.87 inches Install a drinking fountain the meets the required minimum depth. At least 18.00 inches -0.13 inches Install new wall-mounted fountain 2500 ADA 305, 306, 211, 602, CA 11B-602.8 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445266 0 Drinking Fountains 2nd Floor Drinking Fountain Next to Programs Office Detectable Warnings The drinking fountain is not set entirely in an alcove. None Found Provide compliant wing walls or barrier at the drinking fountain. See Recommendation Install wing walls or relocate object 640 ADA 307.2, 602.1, CA 11B-602.9 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446363 0 Locker Rooms 1st Floor Mens Locker Room Is Bench Attached to Wall The bench is not fixed to the wall along the longer dimension. Not Attached Install a compliant bench in the locker room. Provide sufficient clear floor space alongside the the bench to allow a person using a wheelchair to transfer on to the bench. See Recommendation Install bench 500 ADA 222, 803, 903.4, 803.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446364 0 Locker Rooms 1st Floor Mens Locker Room Bench Width The width of the bench is not compliant. 9.50 inches Install a compliant bench in the locker room. Provide sufficient clear floor space alongside the the bench to allow a person using a wheelchair to transfer on to the bench. 20.00 - 24.00 inches -10.50 inches Install bench 500 ADA 222, 803, 903.3, 803.4, CA 11B-803.4,903.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446362 0 Locker Rooms 1st Floor Mens Locker Room Accessible Lockers Availability No accessible lockers were found. None Found Provide a compliant amount of accessible lockers. See Recommendation Requires assembly or design 1840 ADA 222, 803, 225.2, 811, F222.1 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448972 0 Emergency Warning Systems 2nd Floor Visual Alarms Emergency Warning System There are no visual warning devices at the facility. None Found Install visual warning devices integrated with the facility's alarm system in all common areas. See Recommendation Install new audible/visual alarm 2200 ADA 215, 702, CA 11B-215,702 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445209 0 Break/Conference Room 1st Floor Lecture Room Microwave - Appliance Reach Height Appliance Reach Height in the break/conference room is not compliant. 69.25 inches Make sure that the specified appliance reach height is compliant. Up to 48.00 inches 21.25 inches Adjust appliance height 1200 ADA 309, 205, 308, CA 11B-308,309,205 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445204 0 Break/Conference Room 1st Floor Lecture Room Sink Sink - Counter Height Sink counter height does not meet the standards. 35.12 inches Provide compliant sink. Up to 34.00 inches 1.12 inches Provide compliant sink 1800 ADA 606.3, CA 11B-606.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445205 0 Break/Conference Room 1st Floor Lecture Room Sink Toe Kick The toe kick for the sink in break/conference room is not removed. Not Removed Remove the toe kick for the sink. See Recommendation 612 ADA 305, 306, 606.2, CA 11B-606.2,305,306 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445206 0 Break/Conference Room 1st Floor Lecture Room Sink Pipes Wrapping The pipes are not wrapped for the sink. Not Wrapped Insulate or otherwise configure the water supply and drain pipes under the sink to protect against contact. Make certain there are no sharp or abrasive surfaces under the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445207 0 Break/Conference Room 1st Floor Lecture Room Sink Cabinet Door Hardware The cabinet door hardware is not accessible. None Found Provide compliant hardware for the cabinet door. See Recommendation 1000 ADA 309, 205, 308, 228, CA 11B-606.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445208 0 Break/Conference Room 1st Floor Lecture Room Sink Supply Lines Supply lines are not wrapped for the break/conference room sink. Not Wrapped Make sure that the supply lines are fully wrapped and insulated for the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445203 0 Break/Conference Room 1st Floor Lecture Room Table Tables - Knee Depth The table knee depth does not meet required standards. 17.00 inches Provide compliant tables. At least 19.00 inches -2.00 inches Provide compliant seating 2174 ADA 306, 902, CA 11B-306,902 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445341 0 Break/Conference Room 2nd Floor Staff Lounge Microwave - Appliance Reach Height Appliance Reach Height in the break/conference room is not compliant. 68.00 inches Make sure that the specified appliance reach height is compliant. Up to 48.00 inches 20.00 inches Adjust appliance height 1200 ADA 309, 205, 308, CA 11B-308,309,205 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445342 0 Break/Conference Room 2nd Floor Staff Lounge Paper Towel Break Room The height of the controls and operating mechanisms for the dispenser is not at the correct height. 53.00 inches Relocate the dispenser to the correct height. Up to 40.00 inches 13.00 inches Relocate dispenser 110 ADA 309, 308 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445337 0 Break/Conference Room 2nd Floor Staff Lounge Sink Toe Kick The toe kick for the sink in break/conference room is not removed. Not Removed Remove the toe kick for the sink. See Recommendation 612 ADA 305, 306, 606.2, CA 11B-606.2,305,306 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445338 0 Break/Conference Room 2nd Floor Staff Lounge Sink Pipes Wrapping The pipes are not wrapped for the sink. Not Wrapped Insulate or otherwise configure the water supply and drain pipes under the sink to protect against contact. Make certain there are no sharp or abrasive surfaces under the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445339 0 Break/Conference Room 2nd Floor Staff Lounge Sink Cabinet Door Hardware The cabinet door hardware is not accessible. None Found Provide compliant hardware for the cabinet door. See Recommendation 1000 ADA 309, 205, 308, 228, CA 11B-606.4 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445340 0 Break/Conference Room 2nd Floor Staff Lounge Sink Supply Lines Supply lines are not wrapped for the break/conference room sink. Not Wrapped Make sure that the supply lines are fully wrapped and insulated for the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445335 0 Break/Conference Room 2nd Floor Staff Lounge Table Tables - Knee Clearance The table knee clearance does not meet required standards. 26.75 inches Provide compliant tables. At least 27.00 inches -0.25 inches Adjust/Replace Table 500 ADA 305, 306, 902.2, CA 11B-902.2,305,306 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445336 0 Break/Conference Room 2nd Floor Staff Lounge Table Tables - Knee Depth The table knee depth does not meet required standards. 15.75 inches Provide compliant tables. At least 19.00 inches -3.25 inches Provide compliant seating 2174 ADA 306, 902, CA 11B-306,902 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445254 0 Break/Conference Room 1st Floor Training Room Microwave - Appliance Reach Height Appliance Reach Height in the break/conference room is not compliant. 63.00 inches Make sure that the specified appliance reach height is compliant. Up to 48.00 inches 15.00 inches Adjust appliance height 1200 ADA 309, 205, 308, CA 11B-308,309,205 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445249 0 Break/Conference Room 1st Floor Training Room Sink Sink - Counter Height Sink counter height does not meet the standards. 35.87 inches Provide compliant sink. Up to 34.00 inches 1.87 inches Provide compliant sink 1800 ADA 606.3, CA 11B-606.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445250 0 Break/Conference Room 1st Floor Training Room Sink Toe Kick The toe kick for the sink in break/conference room is not removed. Not Removed Remove the toe kick for the sink. See Recommendation 612 ADA 305, 306, 606.2, CA 11B-606.2,305,306 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445251 0 Break/Conference Room 1st Floor Training Room Sink Pipes Wrapping The pipes are not wrapped for the sink. Not Wrapped Insulate or otherwise configure the water supply and drain pipes under the sink to protect against contact. Make certain there are no sharp or abrasive surfaces under the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445252 0 Break/Conference Room 1st Floor Training Room Sink Clear Floor Space Width There is not enough clear floor space at the sink. 22.25 inches Provide enough clear floor space at the location. At least 30.00 inches -7.75 inches Unknown scope 900 ADA 309, 205, 308, 228 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445253 0 Break/Conference Room 1st Floor Training Room Sink Supply Lines Supply lines are not wrapped for the break/conference room sink. Not Wrapped Make sure that the supply lines are fully wrapped and insulated for the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445507 0 Sinks 1st Floor Sink in Crime Lab Paper Towel Sink The height of the controls and operating mechanisms for the dispenser is not at the correct height. 60.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 20.50 inches Replace dispenser 180 ADA 309, 205, 308, 606, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445508 0 Sinks 1st Floor Sink in Crime Lab Soap Sink The height of the controls and operating mechanisms for the dispenser is not at the correct height. 47.50 inches Relocate the dispenser to the correct height. Up to 40.00 inches 7.50 inches Replace dispenser 180 ADA 309, 205, 308, 606, CA 11B-603.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445502 0 Sinks 1st Floor Sink in Crime Lab Sink - Counter Height Sink counter height is not compliant. 36.25 inches Provide compliant sink. Up to 34.00 inches 2.25 inches Provide compliant sink 1800 ADA 606.3, CA 11B-606.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445503 0 Sinks 1st Floor Sink in Crime Lab Sink - Knee Clearance Sink knee clearance does not meet the standards. 24.00 inches Provide compliant sink. At least 27.00 inches -3.00 inches Provide compliant sink 1800 ADA 309, 205, 308, 606, 228, CA 11B-606.2,306.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445504 0 Sinks 1st Floor Sink in Crime Lab Pipes Wrapping The pipes are not wrapped for the sink. Not Wrapped Insulate or Otherwise configure pipes under the sink to protect against contact. Make certain there are no sharp or abrasive surfaces under the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445505 0 Sinks 1st Floor Sink in Crime Lab Toe Kick The toe kick for the sink is not removed. Toe Kick Exists Make sure there is no toe kick at the sink. See Recommendation Remove toe kick 420 ADA 305, 306, 606.2, CA 11B-606.2,305,306 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445506 0 Sinks 1st Floor Sink in Crime Lab Supply Lines Supply lines are not wrapped for the sink. Not Wrapped Make sure that the supply lines are fully wrapped and insulated for the sink. See Recommendation Wrap pipes 149 ADA 606.5, CA 11B-606.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445436 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Controls The shower unit controls are not adjacent to the seat. Not Adjacent to Seat Provide a compliant shower unit. See Recommendation Requires assembly or design 1840 ADA 213, 608, 608.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445437 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Hand Held Unit Hose Length The length of the hose for the hand-held sprayer unit is not compliant. 56.00 inches Provide a compliant hand-held sprayer unit with a hose. At least 59.00 inches -3.00 inches Provide a compliant shower head 385 ADA 213, 608, 608.6, CA 11B-608.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445438 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Twist Control on Hand held Mount The controls on the showers hand held mount are not accessible. Not Compliant Provide accessible controls on the hand held mount. See Recommendation 540 ADA 213, 608, 608.6 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445439 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Seat Length Shower seat length is not compliant. Not Accessible Provide a compliant seat that extends the full length of the shower. See Recommendation Add a compliant fold-down seat to tiled shower wall 1068 ADA 608, CA 11B-608.4,610.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445440 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Seat Width Shower seat width is not compliant. 14.50 inches Provide a compliant shower seat. 15.00 - 22.00 inches -0.50 inches Add fold-down seat and grab bars to tiled shower wall 1500 ADA 608, CA 11B-608.4,610.3 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445441 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Soap Dish Location The soap dish is not mounted on the same wall as the water controls. Not Accessible Relocated the soap dish on the same wall as the water controls at a compliant height. See Recommendation Provide compliant dispenser 277 CA 11B- 608.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445442 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Soap Dish Height The soap dish is not mounted at a compliant height. 58.00 inches Relocated the soap dish on the same wall as the water controls at a compliant height. 15.00 - 40.00 inches 18.00 inches Provide compliant dispenser 277 CA 11B- 608.10 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445443 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Water Valve Distance From Seat Wall The water valve distance from seat wall is not compliant. 17.50 inches Provide a compliant water valve. 19.00 - 27.00 inches -1.50 inches Relocate controls 1500 ADA 213, 608, 608.6, CA 11B-608.5 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445433 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Opening Width The opening width of the shower compartment is less than required. 24.37 inches Increase the shower compartment opening to the correct width. At least 36.00 inches -11.63 inches Requires assembly or design 1840 ADA 213, 608, CA 11B-608.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445434 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Width The shower compartment width is not compliant. 35.00 inches Modify or replace the shower to provide a compliant accessible shower compartment. At least 60.00 inches -25.00 inches Requires assembly or design 3500 ADA 608, 608.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445435 0 Accessible Showers 1st Floor Shower Room Next to Locker Room Accessible Shower There is not enough transfer space available at the shower. 15.50 inches Provide compliant transfer space for the accessible shower. At least 36.00 inches -20.50 inches 1840 ADA 608.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 448973 0 Reach Ranges 2nd Floor 2nd Floor Exterior Emergency Phone Next to Main Entrance - Emergency Call Station Clear Floor Space Slope The clear floor space slope is not compliant. 2.50 percent Provide compliant clear floor space. Up to 2.08 percent 0.42 percent Redesign space 500 ADA 304, CA 11B-305.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 445387 0 Benches 1st Floor Bench in Shower Room Clear Floor Space No clear floor space provided at the bench. Not Found Provide compliant clear floor space for the bench at one end. See Recommendation 1840 ADA 206, 305, 903.2, CA 11B-903.2,305,206 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446403 0 Benches 1st Floor Benches in Booking Area Clear Floor Space No clear floor space provided at the bench. Not Found Provide compliant clear floor space for the bench at one end. See Recommendation 1840 ADA 206, 305, 903.2, CA 11B-903.2,305,206 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446480 0 Benches 1st Floor Benches in Intoxilyzer Room On Accessible Route The bench is not on an accessible route. Not Accessible Provide a compliant accessible route to the benches. See Recommendation Provide compliant route 1840 ADA 309, 903, 305, 205, 308, 228 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 446481 0 Benches 1st Floor Benches in Intoxilyzer Room Clear Floor Space Width Clear floor space width is not compliant for the bench. 24.75 inches Provide compliant clear floor space at the bench. At least 30.00 inches -5.25 inches 1840 ADA 305, 903.2 Landlord Six Not_Started Not_Set 49674 0 No Comments Category_2 0 ENG 980925.84 0 None 0 Landlord 0 Tenant 0 Both 0 City 0 County 0 District 0 Resident 0 Other 0 Police Station Main Picture