Loading...
HomeMy WebLinkAboutBLDG-1276-2023 Stamped Plans_redactedN Plot Plan Note Schedule Property Line (E) Concrete Driveway (E) First Story Rooflines (E) Garage Footprint (E) House Footprint Area of remodel (E) 100 AMP Panel (E) Gas Meter (E) Water 3/4" Meter and 3/4" Copper Service (E) Sidewalk (E) Underground Electrical (E) Gas Line (E) Sewer Lateral (E) 2" Cleanout (E) Sewer Easement 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 SHEET: PROJECT: DATE: 8/4/2023 Designed By: Denise Kneeskern 1560 Santa Rita Road Tempelt on, CA 93465 (805) 434-3339 denise@gannageconst ruct ion.com ANNAGE GDESIGN & CONSTRUCTION ALL DESIGN, IDEAS, SPECIFICATIONS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR USE ON THE SPECIFIED PROJECT AND ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WITHOUT THE WRITTEN CONSENT OF GANNAGE DESIGN & CONSTRUCTION. THEIR USE SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. DRAWN BY: Denise Kneeskern AS-1 Property Owner Tristan Scoble 94 Palomar Dr. San Luis Obispo, CA 93401 Lot Description APN:052-591-003 Address:94 Palomar Dr. Zoning:R-1 Lot Number:003 Lot Area:6000 SF Occupancy & Construction Type Single Family Residence:R-3 Fire Sprinklers: NO Garage:U-1 Fire Sprinklers: NO Construction Type:V-B Stories: Existing Split Level Scope of Work General Notes Code Compliance THIS PROJECT HAD BEEN DESIGNED IN ACCORDANCE WITH AND MEETS THE CITY OF SAN LUIS OBISPO ADOPTED CODE AND ORDINANCE REQUIREMENTS INCLUDING, BUT NOT LIMITED TO, THE CALIFORNIA STATE ACCESSIBILITY STANDARDS AND I/WE WILL BE RESPONSIBLE FOR ALL CLARIFICATIONS DEEMED NECESSARY DURING THE CONSTRUCTION PHASES. This project shall comply with the following model codes: 2022 California Building Code 2022California Residential Code 2022 California Mechanical Code 2022 California Electrical Code 2022California Plumbing Code 2022California Energy Code 2022 California Fire Code 1.THE CONTRACTOR SHALL VISIT PROJECT SITE PRIOR TO BIDDING AND VERIFY ALL EXISTING CONDITIONS. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OR ORDERING OF ANY ITEMS. VERIFY ALL WORK TO BE DONE WITH THE OWNER PRIOR TO CONSTRUCTION. 2.VERIFY WHICH ITEMS, FIXTURES OR APPLIANCES SHALL BE SUPPLIED OR RE-USED BY THE OWNER AND EXACT LOCATION OF SAID ITEMS. UNLESS OTHERWISE NOTED, ITEMS TO BE SAVED WILL BE MARKED WITH BLUE TAPE. 3.THE CONTRACTOR SHALL TAKE CARE DURING DEMOLITION AND CONSTRUCTION NOT TO DAMAGE ANY EXISTING CONSTRUCTION AND PLANTING WHICH IS TO REMAIN. ANY DAMAGE OF EXISTING CONDITIONS SHALL BE REPLACED AT NO COST TO THE OWNER. 4. ALL MATERIALS TO BE REMOVED SHALL BE DISPOSED OF AT AN APPROPRIATE LOCATION AWAY FROM THE SITE UNLESS OTHERWISE ARRANGED. 5. PROVIDE ALL NECESSARY TEMPORARY SUPPORTS, SHORING AND BRACING REQUIRED DURING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING STRUCTURAL INTEGRITY AND SAFETY. 6. MATCH EXISTING FINISH MATERIALS, TEXTURES AND FINISHES UNLESS OTHERWISE NOTED. 7. NEW WALLS, CEILING AND FLOORS INTERSECTING EXISTING WALLS, CEILINGS AND FLOORS SHALL BE FLUSH, CLEAN AND LEVEL. ALL TIE-INS SHALL BE ADEQUATELY SECURE FOR STRUCTURAL INTEGRITY AND SAFETY. 8. PROVIDE CASING BEADS AT ALL EXPOSED DRYWALL EDGES. PROVIDE ALL OTHER MISC. METAL TRIM AS REQUIRED FOR A COMPLETE AND PROPER INSTALLATION. 9. CONTRACTOR SHALL USED WRITTEN DIMENSIONS ONLY. ALL DIMENSIONS ARE TO BE FACE OF STUDS UNLESS OTHERWISE NOTED. 10.STREET NUMBER OR ADDRESS SHALL BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY AND SHALL BE A MIN. OF 4 IN HIGH WITH A MIN. STROKE OF 1/2 IN. ENLARGED SITE PLAN 1"=10' Not to scale VICINITY MAP General Contractor Mikhail Gannage Lic:778043 Gannage Design & Construction 1560 Santa Rita Road Templeton, CA 93465 C: 805-550-6331 O:805-434-3339 EXISTING STRUCTURE: 1. HOUSE 1792 SF 2. GARAGE 491 SF PROPOSED STRUCTURE: 1. HOUSE 2,052 SF (260 SF CONVERSION) 2. GARAGE 231 SF HIGHEST RIDGE:21 FT LOT SF:10000 SF BUILDING FOOTPRINT:1563 SF LOT COVERAGE:26% Area Tabulations Project Overview Per FEMA's flood map. This property is not in a flood hazard area. Layout Page Table Label Title Description Comments AS-1 Project Overview T-1 General Notes T-2 Cal Green Checklist T-3 Cal Green Checklist T-4 Title 24 Calcs T-5 Title 24 Calcs A-1 Existing Layout Demo Plan A-2 Fixture Schedules E-1 Electrical Layout Structural Structural Structural Structural Structural Structural Structural Structural Energy Engineer Carstairs Energy 2238 Bayview Heights Dr STE E Los Osos, CA 93402 (805) 904-9048 - Partial Garage conversion to living City of San Luis Obispo Engineering Notes 1 All work located within the public right-of-way or within the jurisdiction of the Utilities and Public Works Departments shall comply with the most current edition of the Engineering Standards and Standard Specification. 2 Any sections of damaged or displaced curb, gutter & sidewalk, or driveway approach shall be repaired or replaced to the satisfaction of the Public Works Director. 3 A separate encroachment permit is required for any work in the public right-of-way, within city easements, or for connections to public utilities. Work requiring an encroachment permit includes but is not limited to demolitions, utilities, water, sewer, and fire service laterals, curb, gutter, and sidewalk, driveway approached, sidewalk under-drains, storm drain improvements, street tree planting or pruning, curb ramps, street paving, and pedestrian protection, or construction staging tin the right of way. 4 Contact the Public Works inspection hotline at 805-781-7554 with at least a 48-hour notices for any required encroachment permit inspection or final inspection requests. 5 The adjoining street shall be cleaned by sweeping to remove dirt, dust, mud and construction debris at the end of each day. 6 A traffic and pedestrian control plan shall be submitted to the Public Works Departments for review and approval prior to encroachment permit issuance. 7 Any existing survey monuments shall be protected in place or shall be tied out by a licensed land surveyor prior to disturbance and then replaced prior to occupancy in accordance with Section 8771 of the CA Business and Professions Code. 8 Erosion control measures shall be implemented and maintained to the satisfaction of the Building Official and Public Works Director during all demolitions, construction and ground disturbing activities. 9 One 15-gallon street tree is required for each 35LF of frontage or fraction thereof. Tree species and planting requirements shall be per city engineering standards. Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 Existing: 3 bedroom, 2 bathroom Proposed: 4 bedroom, 3 bathroom LOT 3 OF TRACT NO. 545, SERANO SIRCLE, IN THE CITY OF SAN LUIS OBISPO, COUNTY OF SAN LUIS OBISPO, STATE OF CALIFORNIA, ACCORDING TO MAP RECORDED AUGUST 11,1977 IN BOOK 9 PAGE 37 OF MAPS, AND AMENDING MAP RECORDED MARCH 7, 1978 IN BOOK 9 PAGE 52 OF MAPS, IN THE OFFICE OF THE COUTNY RECORDED OF SAID COUNTY ALSO KNOWN AS: 94 PALOMAR AVE, SAN LUIS OBISPO, CA 93405 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division CARPENTRY: SAWN LUMBER DESIGN IS BASED ON THE NATIONAL DESIGN SPECIFICATION, LATEST EDITION. SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. ALL LUMBER NOT SPECIFICALLY NOTED TO BE D.F. #2 OR BETTER. ALL WOOD IN PERMANENT CONTACT WITH CONCRETE OR CMU SHALL BE PRESSURE TREATED UNLESS AN APPROVED BARRIER IS PROVIDED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY (OR ENGINEER APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL HANGERS AND NAILS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE SIMPSON Z-MAX HANGERS OR STAINLESS STEEL. ALL SHEAR WALL SHEATHING NAILS SHALL BE COMMON NAILS ALL FRAMING NAILS SHALL BE COMMON NAILS. OR HOT DIPPED GALVANIZED BOX NAILS. FRAMING NAILS SHALL BE PER IBC TABLE 2304.9.1 OR IRC TABLE R602.3(1). PLYWOOD PANELS SHALL CONFORM TO THE REQUIREMENTS OF "U.S. PRODUCT STANDARD PS 1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD" OR APA PRP-108 PERFORMANCE STANDARDS. UNLESS NOTED, PANELS SHALL BE APA RATED SHEATHING, EXPOSURE 1, OF THE THICKNESS AND SPAN RATING SHOWN ON THE DRAWINGS. PLYWOOD INSTALLATION SHALL BE IN CONFORMANCE WITH APA RECOMMENDATIONS. ALLOW 1/8" SPACING AT PANELS ENDS AND EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. ALL ROOF SHEATHING AND SUB-FLOORING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, EXCEPT AS INDICATED ON THE DRAWINGS. ROOF SHEATHING SHALL EITHER BE BLOCKED, TONGUE-AND-GROOVE, OR HAVE EDGES SUPPORTED BY PLYCLIPS. SHEAR WALL SHEATHING SHALL BE BLOCKED WITH 2X FRAMING AT ALL PANEL EDGES. NAILING NOT SPECIFICALLY IDENTIFIED ON THE DRAWINGS TO CONFORM WITH IRC TABLE R602.3(1). GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH U.S. PRODUCT STANDARD PS 56, "STRUCTURAL GLUED LAMINATED TIMBER" AND AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, AITC 117. EACH MEMBER SHALL BEAR AN AITC OR APA-EWS IDENTIFICATION MARK AND BE ACCOMPANIED BY A CERTIFICATE OF CONFORMANCE. ONE COAT OF END SEALER SHALL BE APPLIED IMMEDIATELY AFTER TRIMMING IN EITHER SHOP OR FIELD. GLULAM HANGERS NOT SHOWN SHALL BE SIMPSON EG. BEAMS SHALL BE VISUALLY GRADED WESTERN SPECIES INDUSTRIAL GRADE, AND OF THE STRENGTH INDICATED BELOW: COMBINATION DEPTH SYMBOL SPECIES USE ALL 24F - V4 DF/DF (SIMPLE SPAN) ALL 24F - V8 DF/DF (CONT. OR CANTILEVER) PREMANUFACTURED WOOD JOISTS: PREMANUFACTURED WOOD JOISTS SHALL BE OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS, MANUFACTURED BY THE TRUS JOIST COMPANY, OR AN ENGINEER APPROVED EQUAL. PROVIDE BRIDGING IN CONFORMANCE WITH THE MANUFACTURERS RECOMMENDATIONS. JOISTS AND BRIDGING SHALL BE CAPABLE OF RESISTING THE WIND UPLIFT NOTED ON THE DRAWINGS. THE JOIST MANUFACTURER SHALL VISIT JOB SITE AS REQUIRED AND VERIFY THE PROPER INSTALLATION OF JOISTS IN WRITING TO THE ARCHITECT/ENGINEER. PREMANUFACTURED WOOD JOIST ALTERNATES WILL BE CONSIDERED, PROVIDED THE ALTERNATE IS COMPATIBLE WITH THE LOAD CAPACITY, STIFFNESS, DIMENSIONAL, AND FIRE RATING REQUIREMENTS OF THE PROJECT, AND IS ICBO APPROVED. LUMBER SPECIES: A.POSTS, BEAMS, HEADERS, JOISTS, AND RAFTERS TO BE DF-#2 B.EXPOSED ARCH BEAMS TO BE DF-#1 OR BETTER C.SILLS, PLATES BLOCKING, AND BRIDGING TO BE DF-#2. D.ALL STUDS TO BE DF#2 OR BETTER. E.PLYWOOD SHEATHING SHALL BE AS FOLLOWS: ROOF SHEATHING SHALL BE 1/2'' CDX INT-APA RATED 32/16. WALL SHEATHING SHALL BE 1/2'' INT-APA RATED 32/16 OR 7/16'' OSB. FLOOR SHEATHING SHALL BE 3/4'' T & G INT-APA RATED OSB. F. ' I ' JOISTS SHALL BE MANUFACTURED BY TRUS JOIST OR ENGINEER APPROVED EQUAL. G. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. LUMBER SPECIES: 1.POSTS, BEAMS, HEADERS, JOISTS, AND RAFTERS TO BE DF-#2. 2.EXPOSED ARCH BEAMS TO BE DF-#1 OR BETTER. 3.SILLS, PLATES BLOCKING, AND BRIDGING TO BE DF-#2. 4.ALL STUDS TO BE DF#2 OR BETTER. 5.PLYWOOD SHEATHING SHALL BE AS FOLLOWS: A. ROOF SHEATHING SHALL BE 5/8" PLYWOOD OR 9/32 OSB. B. WALL SHEATHING SHALL BE 1/2'' INT-APA RATED 32/16 OR 7/16'' OSB. C. FLOOR SHEATHING SHALL BE 3/4'' T & G INT-APA RATED OSB. NAILING NOTES: (PER CRC TABLE R602.3(1)) JOIST TO SILL OR GIRDER TOE NAIL (3)-8d BRIDGING TO JOIST TOE NAIL EA. END (2)-8d SOLE PLATE TO JOIST OR BLK'G FACE NAIL 16d @ 16"OC STUD TO SOLE PLATE TOE NAIL (4)-8d, END NAIL (2) 16d TOP PLATE TO STUD END NAIL (2)-16d DOUBLE STUDS FACE NAIL 16d @ 24" OC DOUBLE TOP PLATES FACE NAIL 16d @ 16" OC CONTINUOUS HEADER, TWO PIECES 16d @ 16" OC ALONG EA. EDGE BUILT-UP HEADER, TWO PIECES W/ 1/2" SPACER 16d @ 16" OC ALONG EA. EDGE TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d CEILING JOISTS TO PLATE TOE NAIL (3)-8d CONTINUOUS HEADER TO STUD TOE NAIL (4)-8d CEILING JOISTS, LAPS OVER PARTITIONS FACE NAIL (3)-10d CEILING JOISTS TO PARALLEL RAFTERS FACE NAIL (3)-10d RAFTER TO PLATE TOE NAIL (2)-16d 1" BRACE TO EACH STUD AND PLATE FACE NAIL (2)-8d BUILT-UP CORNER STUDS 10d @ 24" OC 2" PLANKS (2)-16d @ EA.BRG. 1/2" PLYWOOD ROOF AND WALL EDGES 8d @ 6" OC SHEATHING INTERMEDIATE 8d @ 12" OC 3/4" PLYWOOD SUBFLOOR EDGES 8d @ 6" OC INTERMEDIATE 8d @ 12" OC 2x MULTIPLE JOISTS - STAGGER @ 15" OC W/(2) @ EA. END OR SPLICE (3) OR FEWER 16d NAILS (4) OR MORE 1/2" DIA M.B. W/ STANDARD NUT AND WASHERS GENERAL PLUMBING & HVAC NOTES: 1.METALLIC GAS PIPE, WATER PIPE, AND FOUNDATION REINFORCING BARS SHALL BE BONDED TO THE ELECTRICAL SERVICE GROUND. 2.DRYER, WATER HEATER, KITCHEN AND BATHROOM VENTING SHALL EXHAUST TO THE OUTSIDE OF THE BUILDING AND BE EQUIPPED WITH A BACK DRAFT DAMPER. 3. ALL GAS LINES SHALL BE SIZED FOR APPLIANCE LOAD. "BLACK" PIPE SHALL BE USED INSIDE THE BUILDING, "GREEN" PIPE WHERE UNDERGROUND OR EXPOSED TO WEATHER. ALL JOINTS SHALL BE TAPED WHERE BURIED OR EXPOSED TO WEATHER. 4.TUBS/SHOWERS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING TYPE. THE WATER TEMPERATURE SHALL BE AT A MAXIMUM OF 120*F. WATER SOFTENER UNIT SHALL CONDITION WATER BEFORE ENTERING THE WATER HEATERS AND THE COLD WATER SOURCE. 5.EACH HOSE BIBB SHALL BE EQUIPPED WITH A BACK FLOW PREVENTION DEVICE. HEAT DUCTING SHALL BE SECURED, SEALED AND INSULATED AS APPROPRIATE. 6.INSTALL NON ABSORBENT SURFACE AT ALL WATER SPLASH AREAS TO MINIMUM 72" ABOVE SHOWER DRAINS. 7. DRAINAGE PIPING SERVING FIXTURES WHICH HAVE FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION OF THE NEXT UPSTREAM MANHOLE COVER OF THE PUBLIC OR PRIVATE SEWER SERVING SUCH DRAINAGE PIPING SHALL BE PROTECTED FROM BACKFLOW OF SEWAGE BY INSTALLING AN APPROVED BACKWATER VALVE. 8. ALL EXCAVATIONS ALL BE COMPLETELY BACKFILLED AS SOON AFTER INSPECTION AS PRACTICABLE. A LAYER OF SAN SHALL BE PLACED IN ALL SEWER TRENCHES TO PROVIDE A LEVELING AND LAYING BED FOR PIPE. ADEQUATE PRECAUTION SHALL BE TAKEN TO INSURE PROPER COMPACTNESS OF BACKFILL AROUND PIPING WITHOUT DAMAGE TO SUCH PIPING. TRENCHES ALL BE BACKFILLED IN THIN LAYERS TO 12 INCHES ABOVE THE TOP OF THE PIPING WITH CLEAN EARTH WHICH SHALL NOT CONTAIN STONES, BOULDERS, CINDERFILL, FROZEN EARTH, CONSTRUCTION DEBRIS OR OTHER MATERIALS WHICH WOULD DAMAGE OR BREAK THE PIPING OR CAUSE CORROSIVE ACTION. slomc 15.04.060.b 9. JOINING METHODS AND MATERIALS FOR BUILDING SEWERS SHALL BE AS PRESCRIBED IN THIS CODE AND SHALL ONLY HAVE JOINTS THAT ARE GLUED, SOLVENT CEMENTED, HEAT FUSED OR WELDED. slomc15.04.060.c 10. STORM WATER DRAINAGE MAY BE DIRECTED TO AN APPROVED RAINWATER HARVESTING SYSTEM AND USED AS AN ALTERNATE SOURCE OF WATER FOR NON-POTABLE USES AS APPROVED BY THE BUILDING OFFICIAL AND THE SLO COUNTY ENVIRONMENTAL HEALTH DEPARTMENT. THE INSTALLATION AND USE OF SUCH A SYSTEM OR SYSTEMS MUST BE DESIGNED TO NOT INTERACT WITH THE POTABLE WATER SYSTEM, THE BUILDING SANITARY SEWER OR DRAINAGE SYSTEMS THAT FLOW TO ANY CREEK. RAINWATER HARVESTING SYSTEMS MUST BE MAINTAINED IN SUCH A MANNER AS TO NOT CAUSE DAMAGE TO NEIGHBORING PROPERTIES. slomc 15.04.060.D VENTILATION NOTES: 1.ALL COMBUSTION APPLIANCES WILL BE VENTED DIRECTLY TO THE EXTERIOR. 2.FURNACE FIREBOX AND TANKLESS WATER HEATER SHALL HAVE OUTSIDE COMBUSTION AIR SUPPLY PURSUANT TO REGIONAL AND LOCAL CODES. 3.ATTIC SHALL HAVE VENTILATION EQUAL TO 1 SQ. FOOT PER 150 SQ. FEET OF ATTIC SPACE. VENTILATION SHALL BE PROTECTED FROM SNOW AND RAIN AND SHALL BE COVERED WITH GALVANIZED WIRE SCREEN. OPENINGS SHALL BE LOCATED TO PROVIDE CROSS VENTILATION. IF THE ATTIC IS EQUIPPED WITH HIGH AND LOW VENTILATION OPENINGS WITH 50% OR MORE IN HIGH; VENTILATION SHALL BE EQUAL TO 1 SQ. FEET PER 300 SQ. FEET OF ATTIC SPACE. 4. EXHAUST ALL VENTS AND FANS DIRECTLY TO OUTSIDE VIA METAL DUCTS. 50 CFM (MIN) FANS 5. AIR CHANGES PER HOUR IN BATHS CONTAINING TUB AND / OR SHOWER AND IN LAUNDRY ROOMS. 6. UNDER FLOOR SPACES SHALL HAVE VENTILATION EQUAL TO ONE SQ. FOOT PER 150 SQ. FEET OF FLOOR SPACE. 7. VENTS SHALL BE CAST INTO THE CONCRETE STEM WALLS AND COVERED WITH GALVANIZED WIRE SCREEN. VENTS SHALL BE LOCATED TO PROVIDE CROSS VENTILATION. SHEET: PROJECT: DATE: 8/4/2023 Designed By: Denise Kneeskern 1560 Santa Rita Road Tempelt on, CA 93465 (805) 434-3339 denise@gannageconst ruct ion.com ANNAGE GDESIGN & CONSTRUCTION ALL DESIGN, IDEAS, SPECIFICATIONS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR USE ON THE SPECIFIED PROJECT AND ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WITHOUT THE WRITTEN CONSENT OF GANNAGE DESIGN & CONSTRUCTION. THEIR USE SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. DRAWN BY: Denise Kneeskern T-1 Lead Safe Work Practices REMOLDING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS IN VIOLATION OF THE CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELORS AND PAINTERS ARE REQUIRED TO USE LEAD SAFE WORK PRACTICES PURSUANT TO TITLE 17, CA CODE OF REGULATIONS SECTIONS 26050. CONSTRUCTION DEBRIS KNOWN TO CONTAIN LEAD-BASED PAINT MUST BE DISPOSED AT AN APPROVED LOCATION. CONTACT UTILITIES CONSERVATION AT 805-781-7213. 1.NAILS SHALL BE DRIVEN PERPENDICULAR WHERE POSSIBLE INSTEAD OF TOENAILS. 2.ALL NAILS SHALL BE COMMON WIRE NAILS UNLESS NOTED OTHERWISE. ALL NAILING SHALL CONFORM TO TITLE 24 (2016) TABLE 2304 3.NAILING NOT NOTED ON PLANS SHALL BE IN ACCORDANCE TO THE CBC 2016 EDITION TABLE 2304 4.GREEN VINYL SINKERS DO NOT MEET THE NAILING REQUIREMENTS FOR MOST "BOX AND COMMON NAIL" CONNECTIONS INSULATION NOTES: 1.ATTIC INSULATION OF ALL NEW CONDITIONED SPACES TO HAVE R-38 & FLOOR INSULATION TO HAVE R19, U.O.N 2.ALL NEW EXTERIOR WALLS OF CONDITIONED SPACES TO HAVE R-15, U.O.N. 3.WATERHEATER TO HAVE R12 WRAP 4.DUCTWORK PER CHAPTER 6 OF THE CMC 5.3/4" OR LARGER HOT WATER MAINS TO BE INSULATED WITH R4 OR GREATER UNDER SLAB AND WITHIN WALLS ADDRESS NOTES: BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL BE A MINIMUM OF 5" IN HEIGHT WITH A MINIMUM STROKE WIDTH OF 1/2". WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING ADDRESS CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. Project Notes Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 DOOR AND WINDOW NOTES: EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOW WITH CLEAR OPENING HEIGHT NOT GREATER THAN 44" ABOVE THE FINISH FLOOR HEIGHT AND SHALL HAVE A MINIMUM CLEAR OPENING AREA OF 5.0 SQ. FT ON GROUND LEVEL AND 5.7 SQ. FT FOR SECOND STORY AND ABOVE. EGRESS WINDOWS SHALL NOT HAVE AN CLEAR OPENING LESS THAN 20" WIDE OR 24" HIGH. ALL WALK-THRU DOORS SHALL BE SOLID CORE INTERIOR DOORS SHALL BE PAINTED. ENTRY DOOR TO BE DEFINED BY HOME OWNER PRIOR ORDERING DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4" TIGHT FITTING SOLID CORE DOORS WITH A RATING OF 60 MINUTES. DOOR SHALL BE SELF CLOSING EXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOORWAY SHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. GLAZING IN DOORS SHALL BE DUAL PANE SAFETY GLASS WITH MIN. U-VALUE OF 0.60 GARAGE DOORS TO BE SECTIONAL, OVERHEAD DOORS ALL WINDOWS TO BE U-Factor: .34, SHGC: .30, VT: .57 EXTERIOR FINISH NOTES: 1.EXTERIOR FINISH TO MATCH EXISTING. 2.ROOFING TO BE 30 YEAR ASPHALT OVER 30# FELT, 5/8 CDX PLYWOOD/OSB. 3.DECKING TO BE TREX OR WOOD. FINAL MATERIAL AND COLOR BY OWNER. 4.CHIMNEYS ARE DECORATIVE AND PROVIDE FOR VENTING OF GAS FIREPLACES ONLY. 5.DOWNSPOUTS TO BE COLLECTED AND ROOF RUN OFF TO BE DIRECTED AWAY FROM STRUCTURE PER THE SITE PLAN. 6.FINISH GRADE SHALL SLOPE AWAY FROM STRUCTURE MIN. 1/2" PER FOOT OF RUN FOR 4' MIN. 7.BASALT RETAINING WALLS TO MATCH EXISTING RETAINING WALL. FINISH NOTES: RENDERINGS ARE NOT TO SCALE; ALL RENDERINGS ARE FOR ARTISTIC DEPICTION ONLY. PLAN UPDATES MAY NOT BE REFLECTED IN RENDERINGS. RENDERINGS SHALL NOT BE USED FOR CONSTRUCTION. FINAL FINISHES SHALL BE CONFIRMED WITHIN CO-CONSTRUCT SPECIFICATIONS PRIOR TO INSTALLATION. FOUNDATION NOTES: SLOPE CRAWL SPACE TO DRAIN. MAXIMUM SLOPE IS 2 HORIZ., 1 VERT. BETWEEN FOOTINGS AT DIFFERENT ELEVATIONS. ALL FOOTINGS TO REST ON CLEAN, FIRM UNDISTURBED SOIL. STEP FOOTINGS A REQUIRED TO MAINTAIN REQUIRED DEPTH BELOW FINISH GRADES. CONCRETE STRENGTH, 2500 PSI AT 28 DAYS FOR ALL SLABS. (FOUNDATION DESIGN BASED ON 2,500 PSI). 2500 PSI AT 28 DAYS FOR ALL OTHER CONDITION. MAXIMUM SLUMP, 4" USE ASTM A-615 GRADE 60 DEFORMED REINFORCING BARS UNLESS NOTED OTHERWISE CONCRETE EXPANSION ANCHORS SHALL BE 'SIMPSON WEDGE-ALL STUD ANCHORS' OR ENGINEER APPROVED EQUAL. EPOXY TO BE SIMPSON "SET" ADHESIVE OR APPROVED EQUAL. INFILTRATION, ALL OPENINGS IN THE EXT. BLDG. ENVELOPE SHALL BE SEALED AGAINST AIR INFILTRATION. THE FOLLOWING AREAS MUST BE SEALED. * JOINTS AROUND WINDOW AND DOOR FRAMES * JOINTS BETWEEN WALL CAVITY AND WINDOW/DR. FME. * JOINTS BETWEEN WALL AND FOUNDATION * JOINTS BETWEEN WALL AND ROOF * JOINTS BETWEEN WALL PANELS * UTILITY PENETRATIONS THROUGH EXTERIOR WALLS August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division SHEET: PROJECT: DATE: 8/4/2023 Designed By: Denise Kneeskern 1560 Santa Rita Road Tempelt on, CA 93465 (805) 434-3339 denise@gannageconst ruct ion.com ANNAGE GDESIGN & CONSTRUCTION ALL DESIGN, IDEAS, SPECIFICATIONS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR USE ON THE SPECIFIED PROJECT AND ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WITHOUT THE WRITTEN CONSENT OF GANNAGE DESIGN & CONSTRUCTION. THEIR USE SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. DRAWN BY: Denise Kneeskern T-2 Cal Green Checklist Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division SHEET: PROJECT: DATE: 8/4/2023 Designed By: Denise Kneeskern 1560 Santa Rita Road Tempelt on, CA 93465 (805) 434-3339 denise@gannageconst ruct ion.com ANNAGE GDESIGN & CONSTRUCTION ALL DESIGN, IDEAS, SPECIFICATIONS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR USE ON THE SPECIFIED PROJECT AND ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WITHOUT THE WRITTEN CONSENT OF GANNAGE DESIGN & CONSTRUCTION. THEIR USE SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. DRAWN BY: Denise Kneeskern T-3 Cal Green Checklist Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division SHEET: PROJECT: DATE: 8/4/2023 Designed By: Denise Kneeskern 1560 Santa Rita Road Tempelt on, CA 93465 (805) 434-3339 denise@gannageconst ruct ion.com ANNAGE GDESIGN & CONSTRUCTION ALL DESIGN, IDEAS, SPECIFICATIONS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR USE ON THE SPECIFIED PROJECT AND ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WITHOUT THE WRITTEN CONSENT OF GANNAGE DESIGN & CONSTRUCTION. THEIR USE SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. DRAWN BY: Denise Kneeskern T-4 Title 24 Calcs Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division SHEET: PROJECT: DATE: 8/4/2023 Designed By: Denise Kneeskern 1560 Santa Rita Road Tempelt on, CA 93465 (805) 434-3339 denise@gannageconst ruct ion.com ANNAGE GDESIGN & CONSTRUCTION ALL DESIGN, IDEAS, SPECIFICATIONS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR USE ON THE SPECIFIED PROJECT AND ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WITHOUT THE WRITTEN CONSENT OF GANNAGE DESIGN & CONSTRUCTION. THEIR USE SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. DRAWN BY: Denise Kneeskern T-5 Title 24 Calcs Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division Electrical Plan ELECTRICAL PLAN 1/4"=1' Electrical Plan Scoble- Garage Conversion 94 Palomar Dr. San Luis Obispo, CA 93401 August 28, 2023 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division