HomeMy WebLinkAboutApproved Plans (2nd Submittal - SLO Rep 7-8-22)SYMBOLS : NN A A-2 A A-2 A A-2 A A-2 AA TRU E N ORT H CROSS SECTION DETAIL INTERIOR ELEVATION SECTION LETTER SHEET WHERE SECTION IS LOCATED SHEET WHERE DETAIL IS LOCATED DETAIL NUMBER 1 2 3 4 INTERIOR ELEVATION NUMBER SHEET WHERE INTERIOR ELEVATION IS LOCATED DOOR NUMBER WINDOW NUMBER KEYNOTE REVISION NU MBER DOOR NUMBER WINDOW NUMBER NUMBER OR LETTER REVISION NUMBER BENCHES 2 FT. SEPARATION PG&E TRANSFORMER R R OT T 3 BIKE LOCKERS TRASH ENCL. BELOW PER CITY STDS. SITE PLAN SHEET INDEX LABEL TIT LE A-1.0 SITE PLAN , VIC NITY MAP, PROJECT D AT A, GENERAL NOTES A-2 COLOR ELEVATIONS A-3 CODE AN ALYSIS A-4 FL OOR PLAN A-4.1 MEZZANINE-CO NTR OL ROOMS PLANS A-4.2 ROOF PLAN A-5 DOOR AN D WINDOW SCHEDUL ES, RATED WALLS SPECS, ST OR EFRO NT AND GLAZING SYSTEM A-5.1 TERR COTTA RAIN SC REEN DET AIL S A-6 ELEVATIONS A-6.1 ELEVATIONS A-7 RENDERINGS A-8 SEC TIONS A-8.1 SEC TIONS A-8.2 SEC TIONS A-9 EXI TING PLAN A-10 ACCESSIBILITY DETAILS A-11.1 REFLECD TED CEILING PLAN- 2ND F LOOR A-12 INTERIOR ELEVATIONS A-12.1 INTERIOR ELEVATIONS C1 CIVIL NOTES C2 GRADING PLAN C3 CIVIL DETAIL SHEET C4 UTIL ITY PLAN C-5 UTIL ITY PLAN L-1 CONCEPTUAL LANDSCAPE PLAN L2 CONCEPTUAL LANDSCAPE PLAN S1.2 MAIN FL OOR: FOUND AT ION & F RAMING PLAN S1.3 SEC OND FLOOR: FRAMING PLAN S1.4 LOW ROOF & CATWALK: FRAMING PLAN S1.5 HIGH RO OF: FRAMIN G PLAN M-0.0 MECHANICAL NOTES, LEGEND & ABBREVIATIONS M-1.0 MECHANICAL SCHEDULES M-1.1 MECHANICAL SCHEDULES M-2.0 MECHANICAL DETAILS M-2.1 MECHANICAL DETAILS M-3.0 MECHANICAL BASEMENT LEVEL ZONE PLAN M-3.1 MECHANICAL BASEMENT LEVEL FLOOR PLAN M-3.2 MECHANICAL BASEMENT LEVEL HYDR ONIC PIPING PLAN M-4.0 MECHANICAL FRIST FLOOR ZONE PLAN M-4.1 MECHANICAL FIRST FLOOR PLAN M-4.2 MECHANICAL FIRST FLOOR HYD RONIC PIPING PLAN M-5.0 MECHANICAL SECON D FLO OR ZONE PL AN M-5.1 MECHANICAL SECON D FLO OR PLAN M-5.2 MECHANICAL CATWALK LEVEL FLOOR PLAN M-5.3 MECHANICAL SECON D FLO OR HYDR ONIC PIPING PLAN M-6.0 MECHANICAL ROOF DECK LEVEL ZONEN PLAN M-6.1 MECHANICAL ROOF DECK LEVEL PLAN- ALL ELECTRIC CENTRAL PLANT OPT ION 1 EXHIBIT M-6.2 MECHANICAL ROOF DECK LEVEL FLOOR PLAN- ALL ELECTRIC CEN TRAL PLANT O PTION 2 EXHIBIT M-6.3 MECHANICAL ROOF DECK HYD RON IC PIPIN G PLAN M-7.0 MECHANICAL ROOF DECK LEVEL FLOOR PLAN- STANDARD GAS HEATING EXH IBIT MC-1 MECHANICAL CONTR OLS MC-2 MECHANICAL CONTR OLS MC-3 MECHANICAL CONTR OLS MC-4 MECHANICAL CONTR OLS MC-5 MECHANICAL CONTR OLS P1.0 PLUMBING NOT ES, SCHEDULES, LEGEND & ABBR EVIATIONS P2.0 PLUMBING DETAILS P3.0 PLUMBING BASEMEN T WASTE & VEN T PLAN P3.1 PLUMBING BASMEMEN T WAT ER PLAN P4.0 PLUMBING FIRST FLOOR WASTE & VENT PLAN P4.1 PLUMBING FIRST FLOOR WATER PLAN P5.0 PLUMBING SECOND F LOOR PLAN P6.0 PLUMBING ROOF PLAN E-1 GEN ERAL NOTES, SYMBOLS AND ABBREVIATIONS E-5 SINGLE LIN E D IAGRAM E-6 ELECTRICAL SCHEDULES E-9 ELECTRICAL SITE PLAN E-10 BASEMENT LEVEL POWER PLAN E-11 FIR ST FLOOR POWER PL AN E-12 SEC OND FLOOR POWER PLAN E-13 CATWALK LEVEL POWER PLAN E-14 ROOF POWER PLAN E-15 BASEMENT LEVEL LIGHT ING PLAN E-16 FIR ST FLOOR LIGH TING PLAN E-17 SEC OND FLOOR LIGHTING PLAN E-16 CATWALK LEVEL LIGHTING PLAN E-20 ELECTRICAL DETAILS T-GA001 GEN ERAL ARRANGEMEN TS COVER SHEET & INDEX T-GA002 GEN ERAL ARRANGEMEN TS COORD ZONE PLANS T-GA010 GEN ERAL ARRANGEMEN TS THEATRICAL POWER KEYS & DET AILS T-GA011 GEN ERAL ARRANGEMEN TS THEATRICAL POWER PLANS T-GA012 GEN ERAL ARRANGMENTS THEATRIC AL POWER PLANS T-GA020 GEN ERAL ARRANGEMEN TS THEATRICAL LIG HTING KEYS & DET AIL S T-GA021 GEN ERAL ARRANGEMEN TS THEATRICAL ZONE LIGHTIN G PLANS T-GA022 GEN ERAL ARRANGEMEN TS THEATRICAL ZONE LIGHTIN G PLANS T-GA030 GEN ERAL ARRANGEMEN TS CABLE MANAGEMENT KEY & DETAILS T-GA031 GEN ERAL ARRANGEMEN TS CABLE MANAGEMENT/SERVICES PLAN T-GA032 GEN ERAL ARRANGEMEN TS CABLE MANAGEMENT/SERVICE PLAN S T-GA040 GEN ERAL ARRANGEMEN TS INFRASTR UCTUR E, FINISHES, & DETAILS T-GA041 GEN ERAL ARRANGEMEN TS INFRASTR UCTUR E, FINISHES, & DETAILS T-GA042 GEN ERAL ARRANGEMEN TS INFRASTR UCTUR E, FINISHES, & DETAILS T-GA043 GEN ERAL ARRANGMENTS INF RASTRUCTURE, FINISHES & D ET AILS T-TE111 THEATRE EQUIPMENT BASEMENT LEVEL PLAN T-TE112 THEATRE EQUIPMENT STAGE LEVEL PLAN T-TE113 THEATRE EQUIPMENT BALC ONY LEVEL PLAN T-TE114 THEATRE EQUIPMENT CATWALK LEVEL PLAN T-TE121 THEATRE EQUIPMENT CENTERLINE SECTION T-TE122 THEATRE EQUIPMENT TRANSVERSE SECTIONS T-TE123 THEATRE EQUIPMENT BLAC K BO X SECTIONS T-TE131 THEATRE EQUIPMENT STAGE TRAP PLATFORM DETAILS T-TE132 THEATRE EQUIPMENT CHAIN MO TOR CONTROL SYSTEM T-TL010 THEATRIC AL SWITCH ING AND CON TROL NOTES AND D ET AILS T-TL011 THEATRIC AL LI GHTING SYSTEM SWITCH ING & CTRL BOX SCHEDULES T-TL012 THEATRIC AL LI GHTING SYSTEM SWITCH ING @ CTRL BOX SCHEDULES T-TL021 THEATRIC AL LI GHITNG SWITCH ING AND CON TROL PH ILOSO PHY-T HRUST THEATRE T-TL022 THEATRIC AL LI GHTING SWITCH ING AND CON TROL PH ILOSO PHY- BLACK BOX T-TL111 THEATRIC AL LI GHTING SWITCH ING AND CON TROL PL AN T-TL112 THEATRIC AL LI GHTING SWITCH ING AND CON TROL PL AN T-TL113 THEATRIC AL LI GHTING SWITCH ING AND CON TROL PL AN T-TL114 THEATRIC AL LI GHTING SWITCH ING AND CON TROL PL AN T-TL131 THEATRIC AL LI GHTING FACEPLATE DETAILS T-TS010 THEATRE SEATING NOTES AND DET AILS T-TS111 THEATRE SEATING -INF ILL VOMS PLAN-TH RUST TH EATR E T-TS112 THEATRE SEATING-O PEN VOMS PLAN-THRUST THEATRE T-TS113 THEATRE SEATING-BAL CON Y LEVEL-THRU ST THEATRE T-TS121 THEATRE SEATING THRUST THEAT RE CENTERLINE SEC TION T-TS211 THEATRE SEATING BLACK BOX PLAN CONFIGURATION PLANS- F OR REFERENCE NIC L-1 LANDSCAPE PLAN & COLOR ELEVAT ION L-2 PLANT LIST SITE PLAN, VICNITY MAP, PROJECT DATA, GENERAL NOTES DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-1.0 SCALE: 1 "=10'-0"SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CAVICINITY MAP (NO SCALE)PROJECT LOCATION X APPLICABLE CODES: 1 ST. FLOOR TOTAL:10,562/20,036= 53% OCCUPANCY GROUP: A1 PR OJECT DATA: A.P.N. TBD- LOTS TO BE COMBINED ZONING DESIGNATION: C-D W/ HISTORIC PRESERVATION OVERLAY W/ GENERAL PLAN AMENDMENT LOT SIZE: 20,036 SQ.FT. (USING ASSUMED P.L. AT PARKING GARAGE) PROPOSED COVERAGE: TOTAL LANDSCAPED AREA: TBD- SEE LANDSCAPING SHEETS CONSTRUCTION TYPE VA- FIRE SPRINKLERS PROJECT DESCRIPTION: CONSTRUCT NEW PERFORMING ARTS THEATRE CO NSULTA NTS LIS T AR CHITEC T: BR YCE ENGSTRO M 210 TRAFFIC WAY SUIT E E AR ROYO GRANDE, CA 93420 (805) 235-3385 brycethearchitect@g mail.com CIVIL ENGINE ER: DANIE L SOTELO 3590 SACRAMENTO DRIV E SUITE 210 SAN L UIS OBISPO , CA 934 05 (805) 602-6167d dsotelo@edpincorporated.com 2019 CALIF ORN IA BUILD ING C ODE (CBC) 2019 CALIF ORN IA H IST ORIC AL BUILD ING C ODE (CHBC) 2019 CALIF ORN IA EXISTING BUILDING CODE (CEBC) 2019 CALIF ORN IA GREEN BUILDING STANDARDS CODE (CGBSC ) 2019 CALIF ORN IA MECH ANI CAL C ODE (CMC) 2019 CALIF ORN IA PLUMBING CODE (CPC) 2019 CALIF ORN IA ELECTR ICAL COD E (CEC) 2019 CALIF ORN IA ENERGY CODE (C EC PART 6) 2019 CALIF ORN IA FIRE CODE (CFC) PAD CE RT IFICAT ION A SOILS OR CIVIL ENGINEER TO DETERMINE GRADING PERFORMED IS IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED PLANS AND IS SUITABLE TO SUPPORT THE INTENDED STRUCTURE. LANDSCAPE AR CHITEC T: FIRMA CO NSULTANTS 187 TANK FARM RO AD SA N LUIS OBISPO , CA 93401 (805 ) 781-980 0 lindsay@firmaconsultants.com 1. ALL WORK SHALL CONFORM TO: A) THE MI NIMUM STANDARDS OF THE LATEST EDITION (OR THE CURRENT EDITION IN EFFECT) OF THE CALIFORNIA BUILDING CODE AND ALL RELATED DOCUMENTS THAT ARE PUBLISHED BY THE I.C.C.. WHI CH HAVE BEEN ADOPTED BY THE LOCAL GOVERNING AGENCY; B) ALL REGULATION AND ORDINANCE OF ALL LOCAL GOVERNING AGENCIES; AND C) ANY SPECIAL CONDITIONS REQUIRED BY THE LOCAL GOVERNING AGENCIES. 2. A CERTIFI CATE OF CONSTRUCTION COMPLIANCE, SIGNED BY THE GENERAL CONTRACTOR BASED UPON HIS OBSERVATION OF THE CONSTRUCTION WORK SHALL BE SUBMITTED TO THE INSPECTING BUILDING OFFICIAL PRIOR TO I SSUANCE OF A CERTIFICATE OF OCCUPANCY. 3. ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFI ED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILI TY TO THE EXI STING SI TE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRI BED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDI ATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. 4. OMISSI ONS FROM THE DRAWINGS AND SPECIFICATI ON OR THE MIS-DESCRIPTI ON OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWI NGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS- DESCRIBED DETAILS OF THE WORK AS I F FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFI CATIONS. 5. DIMENSIONS SHOWN SHALL TAKE PRECEDENCE OVER DRAWING SCALE OR PROPORTION. LARGER SCALE DRAWING SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. 6. WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.11 7. THE SOI LS ENGINEER WILL NEED TO VERIFY IN WRITING BY FOOTING INSPECTION, AND PRI OR TO STEEL PLACEMENT, THAT THE FOOTINGS ARE INTO UNI FORM COMPETENT NATIVE MATERIAL OR OTHERWISE PREPARED ACCORDING TO SOILS ENGINEER RECOMMENDATIONS. 8. ANY PERSON USING A TORCH OR OTHER FLAME-PRODUCING DEVICE FOR SWEATING PI PE JOINTS FROM OR IN ANY BUILDING OR STRUCTURE SHALL PROVI DE ONE APPROVED FIRE EXTINGUISHER ON THE PREMISES WHERE SAID BURNING OPERATION IS PERFORMED. COMBUSTIBLE MATERIAL IN THE CLOSE PROXIMI TY OF OPEN FLAME SHALL BE PROTECTED AGAINST IGNITION BY SHI ELDING, WETTING OR OTHER MEANS. IN ALL CASES, A FIRE WATCH SHALL BE MAI NTAINED IN THE VICI NITY OF THE OPERATION FOR ONE-HALF HOUR AFTER THE TORCH OR FLAME-PRODUCING DEVICE HAS BEEN USED. REFER TO C.F.C. CHAPTER 3 FOR ADDI TIONAL MEASURES. 9. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEI R WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSI BILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSI ON (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM BRYCE ENGSTROM: ARCHI TECT PRI OR TO PROCEEDING WITH ANY RELATED WORK. 10. TEMPORARY FACI LITIES: CONTRACTOR SHALL PAY FOR, PROVIDE AND MAINTAIN TEMPORARY FACILITIES FOR PROJECT PROTECTION AND CONSTRUCTION, AND AS REQUIRED BY LOCAL REGULATION AND THESE DOCUMENTS, SUCH FACILI TIES INCLUDE BUT ARE NOT LIMITED TO: TOILETS, LIGHTS, HEATERS, POWER, GAS, FANS, WATER, PHONES, FENCES, SIGNS, SHEDS. ETC. REMOVE FROM SITE UPON COMPLETION OF WORK. OBTAIN BUI LDING OFFICIAL OR FIRE MARTIAL APPROVAL PRIOR TO USE OF ANY TEMPORARY HEATING DEVICE. 11. PROTECTION AND SAFETY: CONTRACTOR SHALL PROVI DE AND BE RESPONSIBLE FOR ALL TIMES (SIGNS, LIGHTS, FENCES, BRACING, ANCHORAGE, FIRE-EXTI NGUISHERS, ETC) NECESSARY FOR THE PROTECTION OF THE PUBLIC, WORKERS, MATERIALS, CONSTRUCTION AND PROPERTY PER LOCAL, STATE, AND FEDERAL REQUIREMENTS (I NCLUDING EARTHQUAKES, FI RES, SPILLS, ACCIDENTS, EROSION, MUD, DUST, ETC.) STAGING OF MATERI ALS AND EQUIPMENT SHALL NOT OVERLOAD ANY EXISTI NG, NEW AND/OR TEMPORARY STRUCTURES ON THE BUILDING SI TE. 12. CHANGES: CHANGES TO APPROVED PLANS AND SPECIFICATIONS SHALL BE MADE ONLY I N WRITING AND SHALL BE APPROVED BY THE ARCHITECT. CONTRACTOR SHALL ASSUME RESPONSIBI LITY AND COSTS FOR ALL CHANGES LATER IN THE PROJECT CAUSED BY THE ORIGINAL CHANGE. 13. SUBSTITUTIONS: SUBSTI TUTIONS REQUIRE OWNER AND ARCHITECTS APPROVAL FAILURE TO GAIN APPROVAL IS SUFFICI ENT GROUNDS FOR ORDERING REMOVAL OF PRODUCT AT CONTRACTOR'S EXPENSE. 14. ALL APPLIANCES, PLUMBING FIXTURES, CABINETS/BUILT-I NS, ACCESSORIES AND FINISHES LISTED ON THE DRAWINGS SHALL BE SPECIFIED BY THE OWNER OR OWNER'S REPRESENTATIVE U.O.N. 15. ALL MECHANICAL DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH 2016 CALIFORNIA MECHANICAL CODE 16. EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES MUST BE IN PLACE AND FUNCTIONAL PRIOR TO THE FIRST INSPECTION. NO INSPECTIONS CAN BE PERFORMED IF THEY ARE NOT IN PLACE OR HAVE FAI LED TO PROVIDE EROSION CONTROL. FAILURE TO MAINTAIN EROSION CONTROL WILL CAUSE INSPECTIONS TO BE DELAYED UNTIL EROSI ON CONTROL MEASURES ARE FUNCTIONAL. 17. AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OCCUPANT OWNER. (THESE NOTES APPLY TO ALL PORTI ONS, PHASES & SUBCONTRACTOS OF THIS PROJECT) USE OF PLANS: THESE PLANS ARE THE PROPERTY OF BRYCE ENGSTROM: ARCHITECT AND MAY NOT BE USED WITHOUT EXPRESS, WRITTEN CONSENT. GENERAL NOTES: RISK CATEGORY: III FIRST FLOOR-10,562 SQ.FT. TOTAL:10,562/20,036= 0.53 FLOOR AREA RATIO: NOTE: NON-LANDSCAPE WATER SAVING FEATURES- COMMISSIONING OPR DOCUCUMENT STATES TARGET WATER SAVING 25% BETTER THAN TITLE 24. SEE LANDSCAPE PLANS FOR LANDSCAPE WATER SAVING FEATURES. NOTE: CONSTRUCTION DOCUMENTS SHALL COMPLY WITH ALL CITY OF SAN LUIS OBISPO GREEN CHECKLIST ITEMS DESCRIPTION OF PROPOSED USE: PERFORMING ARTS THEATRE INCLUDING TWO PERFORMANCE SPACES, LOBBY, AND GREEN ROOM/ACTOR SUPPORT AREAS ON CITY OWNED LOTS. 10,562 SQ.FT. HOURS OF OPERATION- MONDAY THROUGH SUNDAY 9 AM TO 9PM WITH VARIATIONS IN SCHEDULES THROUGHOUT THE WEEK. MAIN EVENING PERFORMANCES ARE THURSDAY-SUNDAY 7-10PM, SATURDAY AND SUNDAY MATINEES AT 2-5 PM. NO PARKING SPACES ON SITE ARE PROPOSED. PARKING: 10,562 GROSS SQ.FT./ 350= 30 CAR PARKING SPACES REQUIRED GREEN BUILDING: PROJECT SHALL COMPLY WITH ALL CITY GREEN BUILDING CHECKLIST REQUIREMENTS PROJECT NARRATIVE: THE NEW SAN LUIS OBISPO REPERTORY THEATRE BUILDING HONORS THE TIME-WORN AND ANCIENT NATIVE BUILDING MATERIALS USED DURING THE MISSION ERA SUCH AS EXTERIOR PLASTER, WHICH IS USED IN ITS TRADITIONAL FORM, AND TERRA COTTA CLAY, WHICH IS USED IN A MODERN, RE-IMAGINED WAY VIA AN INNOVATIVE RAIN SCREEN PANEL SYSTEM. IT ALSO USES 12x12 TERRA COTTA QUARRY TILES AT THE FRONT AND REAR OF THE BUILDING. THE NEW THEATRE LOOKS FORWARD WITH MORE CONTEMPORARY FORMS FOUND IN THE NEIGHBORING CHILDREN'S MUSEUM, AND IN KEEPING WITH CURRENT PLANS FOR THE EVENTUAL ART MUSEUM. IT'S FORMS STEP BACK FROM MONTEREY STREET, HELP BREAK UP THE MORE MONOLITHIC PARKING GARAGE, AND PROVIDES INVITING ENTRANCES TO BOTH BUILDINGS. ACOUSTICIAN: 45dB ACOUSTICS / BILL DOHN ASSOC. P.O. BOX 1406 SAN LUIS OBISPO, CA 93406 (805) 801-3434 dl@45dB.com 30 CAR PARKING SPACES X .40= 12 BIKE PARKING SPACES REQUIRED- 9 SHORT TERM, 3 LONG TERM Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-2SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CACOLOR ELEVATIONS SCALE: 3 /16"=1'-0" SCALE: 3 /16"=1'-0" SCALE: 3 /16"=1'-0" SCALE: 3 /16"=1'-0" ADJACENT TO PARKING GARAGE AT EGRESS COURT SQ.FT. BUSINESS AREA 2092 SQ.FT. FLOOR PLAN CODE ANALYSIS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-3SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 "=16'-0" BUILDING AREAS: TOTAL B UILDIN G AREA:10,465 SQ.FT . ALLOWABLE AREA AGGREGATE A-1: ALLOWABLE AREA PER FLOOR/OCCUPANCY: CBC 508.3 NONSEPARATED OCCUPANC IES TYPE VA CONST RUC TION FIR E SPRINKLERS THROUGHOUT MAXIMUM H EIGHT: 70' MAXIMUM N UMBER OF STORIES: 3 AL LOWABL E AREA PER FLOOR A-1= 3 4,500 NO HEIGH T INCR EASE NO AREA IN CREASE CALC PER 508.4.2- 10,645/34,500= .31 =.55 < 1 OK CBC 508.3 NO NSEPARATED OCCUPANCIES TYPE VA CONSTRUC TION FIR E SPRINKL ERS THROUGHOUT ALLOWABLE AREA PER FLOOR A-1=34 ,500 ALLOWABLE AREA PER FLOOR B= 54,000 CAL C: 3310/34,500= .23 2092/54,000= .04 .23+.04= .27<2 OK 8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT 8 INCH NOM. STUDS 16" O.C. W/ 2 LAYERS 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT INTERIOR 1 HOUR WALL + SOUND CONTROL INTERIOR 1 HOUR WALL + SOUND CONTROL EXTERIOR GLASS CURTAIN WALL TYPE VA CONST. 11 22 44 55 66 77 88 99 1010 1111 1212 WALL LE GEND FLOOR PLAN DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-4SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" PLUMBING FIXTURE CALC S: FIXT URES OCCU PANT LOAD: 296 F IXED SEATS/ 2= 14 8 1735 SQ.FT. STAGES/ 116 2092 SQ.FT. BUS. AREA/200=11 TOTAL: 2 75 138 MALE 138 FEMALE WATER CLOSETS: MALE: 2 REQU IRED 5 PROVIDED FEMALE: 4 REQUIRED 10 PR OVIDED URIN ALS: 1 REQU IRED 3 PROVIDED LAVAT ORIES: MALE: 1 REQUI RED 5 PROVIDED FEMALE: 2 R EQUIRED 6 PROVIDED DRIN KIN G FNT. 1 REQUIRED 1 PROVIDED * SEE MASTER WALL LEGEND AND RATED WALL SPECS SHEET A-5 5050 OPENING IN PARAPET WAL L W/ STA CKED TERRA COTTA ROOF TILES PE R ELEVATIONS PROVIDE 22V 30 AMP POWER FOR MO VIE PROJECTO R. REQUIRES VENT FOR LAMP ACCESSIBLE DRINKING FOUNT AIN IN ALCOVE PER C ODE SPIRAL ST AIR ACCESS TO CONTRO L ROOM- LIMITED ACCESS SPACE PER CB C 11B-20 3.4 FIRE RISER (EXPOSED ) ADA LIFT ACCESS TO CONTROL ROOM- LIMITED ACC ESS SPACE PER CBC 11B-203.4 STEEL/CONCRETE STAIR/LANDING SOLAR PANELS ROOF AC CESS LADD ER W/ ROOF HATCH A BOVE ROOF AC CESS HATCH 6" KAWNEER S TOREFRONT W/ ELECTROCHRO MIC GLASS FOLDING CHANGING TABLE 2 INCH ROOF DRAIN W/ OVE RFLOW P.V. SOLAR PANELS (SUGGESTED LOCATION AND NUMBER, SUBJECT TO COORD. WITH MECHA NIC AL SYSTEMS POWDER COATED ALUMINUM AWNINGS ABOVE PER E LEVATIONS MOP SINK AND FAUC ET ELEC. HEA T PUMP WA TER HEATE R STEEL CATWALKS ABOVE PER THE ATRE DNA DRAWINGS 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 ROOFING (TYP.) T.P.O. ROOFING (TYP.) T.P.O. ROOFING (TYP.) T.P.O. ROOFING (TYP.)T.P.O. ROOFING (TYP.)1010 1313 1313 1313 1313 1313 1414 1414 1414 1818 1818 1818 1818 ROOF/MEZZANINE PLAN MEZZANINE-CONTROL ROOMS PLANS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-4.1SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CA* SEE MASTER WALL LEGEND AND RATED WALL SPECS SHEET A-5 SCALE: 1 /4"=1'-0" 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 FLOOR PLAN NOTES ROOF PLAN DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-4.2SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" NUMBER QTY FLOOR SIZE DESC RIPTION THICKNESS FIRE RATING PANIC HARDWARE COMMENTS D01 1 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/4"1 HOUR YES D02 1 2 8080 INSULATED STEEL ROLL UP DOOR 1 3/4" D03 3 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"1 HOUR YES D04 1 2 3068 R IN HINGED-SLA B 1 3/8"1 HOUR D05 1 3 3068 L IN HINGED-SLA B 1 3/8" D06 2 3 3068 R IN HINGED-SLA B 1 3/8" D07 1 2 3068 R IN HINGED-SLA B 1 3/8"1 HOUR YES D08 1 2 3068 R EX POWDER COA TED COMMERCIAL EX TERIOR STEEL DOOR 1 3/4"YES FULL PERIMTER WEATHER STRIPPING D09 1 2 41068 MULLED UNIT YES D10 1 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"1 HOUR PEMK O 319 GASKETING D11 1 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"1 HOUR PEMK O 319 GASKETING D12 2 2 3068 R EX POWDER COA TED COMMERCIAL EX TERIOR STEEL DOOR 1 3/4"YES FULL PERIMITER WEATHER STRIPPING, STC MIN. RA TING 50 D13 1 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/4"45 MINUT ES D14 1 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/4"45 MINUT ES D15 1 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"1 HOUR D16 2 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"1 HOUR D17 1 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"PEMK O 319 GASKETING D18 3 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"PEMK O 319 GASKETING D19 1 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/4"1 HOUR YES D20 1 2 3083 R EX BRUSHED ALUMINUM FRAME TEMPERED GLASS DOOR 1 3/4"YES FULL PERIMTER WEATHER STRIPPING D21 1 3 3068 L IN PAINTED SO LID CORE MASONITE IN TERIOR DOOR 1 3/8"PEMK O 319 GASKETING AND 412 DO OR BOTTOM D22 1 2 6083 L/R EX BRUSHED ALUMINUM FRAME TEMPERED GLASS DOOR 1 3/4"YES FULL PERIMTER WEATHER STRIPPING D23 3 2 8090 L/R IN METAL ROLL UP DOOR 1 3/8"1 HOUR STC RATING MIN. 50 D24 1 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"45 MINUT ES D25 1 2 3068 L IN WALNUT VENEER SOLID CORE SLAB IN TERIOR DOOR 1 3/8" D26 2 2 3068 L EX POWDER COA TED COMMERCIAL EX TERIOR STEEL DOOR 1 3/4"YES FULL PERIMTER WEATHER STRIPPING D27 2 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"45 MINUT ES PEMK O 319 GASKETING D28 1 3 3068 R IN PAINTED SO LID CORE MASONITE IN TERIOR DOOR 1 3/8"PEMK O 319 GASKETING AND 412 DO OR BOTTOM D29 2 2 6096 L/R IN WALNUT VENEER SOLID CORE SLAB IN TERIOR DOOR 1 3/8"PEMK O 319 GASKETING D30 1 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"1 HOUR YES D31 2 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"45 MINUT ES D32 1 2 3068 L IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/8"45 MINUT ES PEMK O 319 GASKETING D33 1 2 3068 R IN POWDER COA TED COMMERCIAL INTERIOR STE EL DOOR 1 3/4"45 MINUT ES YES D34 1 2 41068 MULLED UNIT 1 HOUR YES DOOR SCHEDULE NUMBE R QTY FLOOR SIZE DESC RIPTION TEMPERED COMMEN TS W01 2 2 5016FX FIXED GLASS W02 2 3 4040LS LE FT SLIDING W03 6 3 8020FX FIXED GLASS MOTORIZ ED INTERIO R BLACKOUT SCREENS W04 1 3 9240TS TRIPLE SLIDING W05 1 3 6040FX FIXED GLASS W06 2 2 5050FX FIXED GLASS YES W07 1 3 6040LS LE FT SLIDING W08 1 3 6040RS RIGHT SLIDING W09 1 2 6050FX FIXED GLASS W10 2 2 6060FX FIXED GLASS NOTE: ALL EXTERIOR WINDOW FRAMES TO BE BRUSHED OR ANODIZED ALUMINUM FRAMES TO MATCH STOREFRONT GLASS. WINDOW SCHEDULE EXTERIOR 2 HOUR WALL INTERIOR 1 HOUR WALL INTERIOR 1 HOUR WALL EXTERIOR TERRA COTTA PANEL WALL TYPE VA CONSTRUCTION EXTERIOR STUCCO OR TILE WALL TYPE VA CONSTRUCTION INTERIOR BEARING PARTITION INTERIOR NON BEARING PARTITION INTERIOR NON BEARING PARTITION HOURLY RATING: 1-HOUR STC RATING: 45-49 STC FIRE TEST REFERENCE: UL U465, ULC W415 FOR TYPE X ONLY, CUL U465, GA WP 10812 SOUND TEST REFERENCE: RAL TL99-1035/8” (15.9 MM) TOUGHROCK® FIREGUARD X® OR 5/8” (15.9 MM) DENSARMOR PLUS® FIREGUARD® GYPSUM PANELS APPLIED VERTICALLY TO EACH SIDE OF 3-5/8” (92 MM) STEEL STUDS 24” (610 MM) O.C. WITH 1” (25 MM) TYPE S DRYWALL SCREWS 8” (203 MM) O.C. AT EDGES AND 12” (305 MM) O.C. AT INTERMEDIATE STUDS. SOUND TESTED WITH 3” (76 MM) MINERAL FIBER, 2.5 PCF (40.1 KG/M3), IN STUD SPACE. NON-LOAD BEARING APPROVED FOR ASSEMBLY: DENSARMOR PLUS® FIREGUARD C® PRODUCTS DENSARMOR PLUS® FIREGUARD® PRODUCTS DENSELEMENT® BARRIER SHEATHING DENSGLASS® FIREGUARD® SHEATHING DENSSHIELD® FIREGUARD® TILE BACKER TOUGHROCK® FIREGUARD C® PRODUCTS TOUGHROCK® FIREGUARD X® MOLD-GUARD™ PRODUCTS TOUGHROCK® FIREGUARD X® PRODUCTS TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS (MEETS FIRE RATING BUT NOT INCLUDED IN SOUND TESTING) INTERIOR 1 HR. MIN. FIRE RATED WALLS 6 INCH NOM. STUDS 16" O.C. W/ 2 LAYERS 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT 4 INCH NOM. STUDS 16" O.C. W/ 1 LAYER 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT 6 INCH NOM. STUDS 16" O.C. W/ 1 LAYER 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT 4 INCH NOM. STUDS 16" O.C. W/ 1 LAYER 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT HOURLY RATING: 1-HOUR STC RATING: FIRE TEST REFERENCE: GA WP 3520 SOUND TEST REFERENCE: WOOD-FRAMED WALL 5/8” (15.9 MM) TOUGHROCK® FIREGUARD X™ OR 5/8” (15.9 MM) DENSARMOR PLUS FIREGUARD GYPSUM BOARD APPLIED VERTICALLY TO EACH SIDE OF 2” X 4” WOOD STUDS 24” (610 MM) O.C. WITH 1-7/8” (48 MM) 6D COATED NAILS 7” (178 MM) O.C. AT JOINTS AND TOP AND BOTTOM PLATES AND 3/8”(10 MM) BEADS OF ADHESIVE AT INTERMEDIATE STUDS. JOINTS STAGGERED 24″ ON OPPOSITE SIDES. APPROVED FOR ASSEMBLY: DENSARMOR PLUS® FIREGUARD C® PRODUCTS,DENSARMOR PLUS® FIREGUARD® PRODUCTS,DENSELEMENT™ BARRIER SHEATHING,DENSGLASS® FIREGUARD® SHEATHING,DENSSHIELD® FIREGUARD® TILE BACKER,TOUGHROCK® FIREGUARD C® PRODUCTS,TOUGHROCK® FIREGUARD X® MOLD-GUARD™ PRODUCTS,TOUGHROCK® FIREGUARD X® PRODUCTS,TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS PROPRIETARY HOURLY RATING: 1-HOUR STC RATING: FIRE TEST REFERENCE: UL U309, CUL U309, GA WP 8109 SOUND TEST REFERENCE: EXTERIOR WOOD-FRAMED WALL EXTERIOR SIDE: 5/8” (15.9 MM) DENSGLASS® FIREGUARD® SHEATHING APPLIED VERTICALLY OR HORIZONTALLY TO 2”X 4” WOOD STUDS 24” (610 MM) O.C. WITH 1-7/8” (48 MM) GALVANIZED ROOFING NAILS 7” (178 MM) O.C. JOINTS OF GYPSUM SHEATHING MAY BE LEFT UNTREATED. EXTERIOR CLADDING TO BE ATTACHED THROUGH SHEATHING TO STUDS. INTERIOR SIDE: 5/8” (15.9 MM) TOUGHROCK® FIREGUARD X® PRODUCTS OR 5/8” (15.9 MM) DENSARMOR PLUS® FIREGUARD® GYPSUM PANELS APPLIED VERTICALLY OR HORIZONTALLY TO STUDS WITH 1-7/8” (48 MM) 6D COATED NAILS 7” (178 MM) O.C. APPROVED FOR ASSEMBLY: DENSARMOR PLUS® FIREGUARD C® PRODUCTS, DENSARMOR PLUS® FIREGUARD® PRODUCTS, DENSELEMENT® BARRIER SHEATHING, DENSGLASS® FIREGUARD® SHEATHING, DENSSHIELD® FIREGUARD® TILE BACKER, TOUGHROCK® FIREGUARD C® PRODUCTS, TOUGHROCK® FIREGUARD X® MOLD-GUARD® PRODUCTS, TOUGHROCK® FIREGUARD X® PRODUCTS, TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS PROPRIETARY HOURLY RATING: 1-HOUR STC RATING: FIRE TEST REFERENCE: UL U309, CUL U309, GA WP 8109 SOUND TEST REFERENCE: EXTERIOR WOOD-FRAMED WALL EXTERIOR SIDE: 5/8” (15.9 MM) DENSGLASS® FIREGUARD® SHEATHING APPLIED VERTICALLY OR HORIZONTALLY TO 2”X 4” WOOD STUDS 24” (610 MM) O.C. WITH 1-7/8” (48 MM) GALVANIZED ROOFING NAILS 7” (178 MM) O.C. JOINTS OF GYPSUM SHEATHING MAY BE LEFT UNTREATED. EXTERIOR CLADDING TO BE ATTACHED THROUGH SHEATHING TO STUDS. INTERIOR SIDE: 5/8” (15.9 MM) TOUGHROCK® FIREGUARD X® PRODUCTS OR 5/8” (15.9 MM) DENSARMOR PLUS® FIREGUARD® GYPSUM PANELS APPLIED VERTICALLY OR HORIZONTALLY TO STUDS WITH 1-7/8” (48 MM) 6D COATED NAILS 7” (178 MM) O.C. APPROVED FOR ASSEMBLY: DENSARMOR PLUS® FIREGUARD C® PRODUCTS, DENSARMOR PLUS® FIREGUARD® PRODUCTS, DENSELEMENT® BARRIER SHEATHING, DENSGLASS® FIREGUARD® SHEATHING, DENSSHIELD® FIREGUARD® TILE BACKER, TOUGHROCK® FIREGUARD C® PRODUCTS, TOUGHROCK® FIREGUARD X® MOLD-GUARD® PRODUCTS, TOUGHROCK® FIREGUARD X® PRODUCTS, TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS EXTERIOR 1 HR. MIN. FIRE RATED WALLS 8 INCH NOM. STUDS 16" O.C. W/ 2 LAYERS 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT 4 INCH NOM. STUDS 16" O.C. W/ 2 LAYERS 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT 8 INCH NOM. STUDS 16" O.C. W/ 2 LAYERS 5/8" TYPE X GYPSUM EA. SIDE, INSULATED, AIR TIGHT EXTERIOR 2 HR. MIN. FIRE RATED WALLS PROPRIETARY HOURLY RATING: 2-HOUR STC RATING: FIRE TEST REFERENCE: UL U301, CUL U301, GA WP8416 SOUND TEST REFERENCE: EXTERIOR WOOD-FRAMED WALL EXTERIOR: TWO LAYERS 5/8” (15.9 MM) DENSGLASS® FIREGUARD SHEATHING APPLIED VERTICALLY OR HORIZONTALLY TO 2 X 4 WOOD STUDS 16” (406 MM) O.C. BASE LAYER ATTACHED WITH 1-7/8” (48 MM) GALVANIZED ROOFING NAILS 16” (406 MM) O.C. FACE LAYER ATTACHED WITH 2-3/8” (60 MM) GALVANIZED ROOFING NAILS 8” (203 MM) O.C. STAGGER JOINTS BETWEEN LAYERS AND ON BASE LAYER OF BOTH SIDES. INTERIOR: TWO LAYERS 5/8” (15.9 MM) DENSARMOR PLUS® FIREGUARD® OR 5/8” (15.9 MM) TOUGHROCK® FIREGUARD X® APPLIED HORIZONTALLY OR VERTICALLY TO FRAMING. BASE LAYER ATTACHED WITH 1-7/8” (48 MM) 6D CEMENT COATED NAILS 6” (152 MM) O.C. FACE LAYER ATTACHED WITH 2-3/8” (60 MM) 6D CEMENT COATED NAILS 8” (203 MM) O.C. STAGGER JOINTS BETWEEN LAYERS AND ON BASE LAYER OF BOTH SIDES. SOUND TESTED WITH STUDS 16” (406 MM) O.C. AND NAILS FOR BASE LAYER SPACED 6” (152 MM) O.C. APPROVED FOR ASSEMBLY: DENSARMOR PLUS® FIREGUARD C® PRODUCTS, DENSARMOR PLUS® FIREGUARD® PRODUCTS, DENSELEMENT® BARRIER SHEATHING, DENSGLASS® FIREGUARD® SHEATHING, DENSSHIELD® FIREGUARD® TILE BACKER, TOUGHROCK® FIREGUARD C® PRODUCTS, TOUGHROCK® FIREGUARD X® MOLD-GUARD® PRODUCTS, TOUGHROCK® FIREGUARD X® PRODUCTS, TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS INTERIOR 1 HOUR WALL + SOUND CONTROL INTERIOR 1 HOUR WALL + SOUND CONTROL EXTERIOR GLASS CURTAIN WALL TYPE VA CONST. 11 22 44 55 66 77 88 99 1010 1111 1212 6655 11224411111010 PROPRIETARY HOURLY RATING: 2-HOUR STC RATING: FIRE TEST REFERENCE: UL U425, CUL U425, GA WP 8203 SOUND TEST REFERENCE: EXTERIOR STEEL-FRAMED WALL EXTERIOR: TWO LAYERS 5/8” (15.9 MM) DENSGLASS® FIREGUARD® SHEATHING APPLIED VERTICALLY TO MIN. 3-1/2” (89 MM) CORROSION RESISTANT 20-GAUGE (30 MILS) STEEL STUDS 24” (610 MM) O.C. BASE LAYER ATTACHED WITH 1” (25 MM) TYPE S-12 CORROSION RESISTANT BUGLE HEAD SCREWS 8” (203 MM) O.C. FACE LAYER ATTACHED WITH 1-5/8” (41 MM) TYPE S-12 CORROSION RESISTANT BUGLE HEAD SCREWS SPACED 8” (203 MM) O.C. JOINTS STAGGERED. INTERIOR: TWO LAYERS 5/8” (15.9 MM) DENSARMOR PLUS® FIREGUARD® OR 5/8” (15.9 MM) TOUGHROCK® FIREGUARD X® PRODUCTS APPLIED VERTICALLY TO FRAMING. BASE LAYER ATTACHED WITH 1” (25 MM) TYPE S-12 BUGLE HEAD SCREWS 12” (305 MM) O.C. FACE LAYER ATTACHED WITH 1-5/8” (41 MM) TYPE S-12 BUGLE HEAD SCREWS SPACED 12” (305 MM) O.C. JOINTS STAGGERED. INSULATION TO COMPLETELY FILL STUD CAVITY. (LOAD BEARING: 80% OF DESIGN LOAD) APPROVED FOR ASSEMBLY: DENSARMOR PLUS® FIREGUARD C® PRODUCTS, DENSARMOR PLUS® FIREGUARD® PRODUCTS, DENSELEMENT® BARRIER SHEATHING, DENSGLASS® FIREGUARD® SHEATHING, DENSSHIELD® FIREGUARD® TILE BACKER, TOUGHROCK® FIREGUARD C® PRODUCTS, TOUGHROCK® FIREGUARD X® MOLD-GUARD® PRODUCTS, TOUGHROCK® FIREGUARD X® PRODUCTS, TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS WALL LEGEND AND RATED WALLS SPEC S DOOR AND WINDOW SCHEDULES, RATED WALLS SPECS, STOREFRONT AND GLAZING SYSTEM DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-5SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CA*NOTE: ALL INTERIOR DOORS TO BE MIN. 18 GA. STEEL FULLY INSULATED HM OR SOLID WOOD PANEL STOREFRONT FRAMING SYSTEMELECTROCHROMIC GLASS SPECS TERR COTTA RAIN SCREEN DETAILS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-5.1SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CAWood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood EXTERIOR AWNINGS CLA DDING C ORP. TERRA 5 TERRA COT TA RAINSCREEN. TC30 300MM P LANKS. COLORS- SE SAME, FAWN, EARTH RED AND VENET IAN . COLOR LOCATIONS PER COLOR ELEVAT IONS- CONFIRM WITH A.O.R. BRUS HED ALUMINUM WIN DOW FRAMES SMOOTH TROWELED PLASTER IN DUN COLOR. 6X 6 VARIAGATED TERRA COTTA TILE 12X12 TERRA COTTA QUA RRY T ILE KAWNEER ALUMINUM STOREFRONT SEE SPECS & D ETAILS SHEET A-6 ELECTROCHR OMIC GLAZING SYSTEM SEE SPECS & D ETAILS SHEET A-6 POWDER COA TED ALUMINUM AWNINGS IN TERRA COTTA COLOR POWDER COA TED ALUMINUM SLO RE P SIGN IN BLACK COL OR- 96"WX96"HX 1/ 4"D LED B ACKLIT BRUS HED ALUMINUM DOWNLIGHT SC ONCE- ALVA TESS- LED 13W-S EE LIGHTING SPEC S SHEET A-9 EXT ERIO R MA RQUEE- 96"WX66"HX14"D- INTE RNALLY LIT LED REMOVABLE BOLLARDS POWDER COA TED METAL DOO RS- TE RRA COTTA COLOR GRASSCRETE RAMP STA CKED TERRA COTTA ROOF TILES IN PARAPET O PENING ROCK CAST CHIS ELED ST-206 COLOR -FLAX INSULATED METAL ROLL UP DOOR- TERRA COTTA COLOR PUBL IC ART (T.B.D.) 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 ELEVA TION NOTES as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-6SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" SCALE: 1 /4"=1'-0" NORTH (P ARKING GARAGE SIDE) ELEVATION EAST (PLAZA) EL EVATION CLA DDING C ORP. TERRA 5 TERRA COT TA RAINSCREEN. TC30 300MM P LANKS. COLORS- SE SAME, FAWN, EARTH RED AND VENET IAN . COLOR LOCATIONS PER COLOR ELEVAT IONS- CONFIRM WITH A.O.R. BRUS HED ALUMINUM WIN DOW FRAMES SMOOTH TROWELED PLASTER IN DUN COLOR. 6X 6 VARIAGATED TERRA COTTA TILE 12X12 TERRA COTTA QUA RRY T ILE KAWNEER ALUMINUM STOREFRONT SEE SPECS & D ETAILS SHEET A-6 ELECTROCHR OMIC GLAZING SYSTEM SEE SPECS & D ETAILS SHEET A-6 POWDER COA TED ALUMINUM AWNINGS IN TERRA COTTA COLOR POWDER COA TED ALUMINUM SLO RE P SIGN IN BLACK COL OR- 96"WX96"HX 1/ 4"D LED B ACKLIT BRUS HED ALUMINUM DOWNLIGHT SC ONCE- ALVA TESS- LED 13W-S EE LIGHTING SPEC S SHEET A-9 EXT ERIO R MA RQUEE- 96"WX66"HX14"D- INTE RNALLY LIT LED REMOVABLE BOLLARDS POWDER COA TED METAL DOO RS- TE RRA COTTA COLOR GRASSCRETE RAMP STA CKED TERRA COTTA ROOF TILES IN PARAPET O PENING ROCK CAST CHIS ELED ST-206 COLOR -FLAX INSULATED METAL ROLL UP DOOR- TERRA COTTA COLOR PUBL IC ART (T.B.D.) 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 ELEVA TION NOTES ELEVATIONS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-6.1SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"= 1'-0" SCALE: 1 /4"= 1'-0" RENDERINGS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-7SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CA 1717 99 4'-6"9'-1 1/2"4'-0"MAIN THEATRE LIGHTING POSITION LIGHTING POSITION LIFT/STAIR ACCESS LIFT/STAIR ACCESS VESTIBULE LOBBY 11 55 22 33 99 1111 22 33 22 33 11 11 88 88 99 1111 1111 1313 F.F. 201.40' F.F. 218.86' PLATE 239.28' PARAPET 243.28' F.F. 201.40' PLATE 217.98' PLATE 239.28' PARAPET 243.28' PARAPET 222.81' PLATE 224.65' PARAPET 230.15' SECTION B ROOF INSULATION PER ENERGY DOCUME NTATION EXT. WALL INSULATION PER ENERGY DOCUME NTATION EXT. WALL RIGID INSULATION PER ENERGY DO CUMENTAT ION R-19 FIB. BATT INSULATION R-30 FIB. BATT INSULATION SUSPENDED T-BAR CEILING R-13 FIB. BATT INSULATION CONC. SLAB / FOOTING PER ENG. 42" H. STEE L GUARDRAIL A.D.A. LIFT TO CO NTROL ROOM T.P.O. ROOFIN G OVER SHAPED FOAM PER ROOF PLAN WOOD FRAMED S EATING PLATFORM PER ENG. RECESS CONC. FLOOR W/ BUILT-UP PLY S TAGE PER THEA TRE DNA DRAWINGS STEEL SPIRAL STAIR- CONTROL R OOM / CATWALK A CCESS ONLY STACKED TERRA COT TA ROOF TILES IN PARAPET OPENING POWDER COATED ALUMINUM AWNING CAT WALKS PER THEATR E DNA & S TRUCT. DRAWINGS 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 SECTION NOTES SECTIONS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-8SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" SCALE: 1 /4"=1'-0" 55 1313 ACCESS SPACE1 HOUR RATED CORRIDOR 1 HOUR RATED CORRIDOR 11 33 55 1111 1111 11 22 5555 44 33 22 33 22 44 8888 1414 1010 44 CAT WALK ACCESS F.F. 201.40' F.F. 218.84' PLATE 239.25' PARAPET 243.25' F.F. 201.40' PARAPET 218.96' PLATE 239.25' PARAPET 243.25' F.S. 190.34' F.F. 229.93' PLATE 214.46' SECTION D ROOF INSULATION PER ENERGY DOCUMENTATION EXT. WALL INSULATION PER ENERGY DOCUME NTATION EXT. WALL RIGID INS ULATION PER ENERGY DO CUMENTAT ION R-19 FIB. BATT INSULATION R-30 FIB. BATT INSULATION SUSPENDED T-BAR CEILING R-13 FIB. BATT INSULATION CONC. SLAB / FOOTING PER ENG. 42" H . STEEL GUARDRAIL A.D.A. LIFT TO CO NTROL ROOM T.P.O. ROOFING OVER SHAPED FOAM P ER ROOF PLAN WOOD FRAMED S EATING PLAT FORM PER ENG. RECESS CONC. FLOOR W/ BUILT-UP PLY STAGE PER THEA TRE DNA DRAWINGS STEEL SPIRAL STAIR- CONTROL R OOM / CATWALK ACCESS ONLY STACKED TERRA COTTA ROOF TILES IN PARAPE T OPENING POWDER COATED ALUMINUM AWNING CAT WALKS PER THEATR E DNA & S TRUCT. DRAWINGS 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 SECTION NOTES SECTIONS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-8.1SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" SCALE: 1 /4"=1'-0" 11 1313 1616 17171717 F.F. 201.40' PLATE 233.78' PARAPET 236.82' F.F. 214.53' F.F. 222.69' SECTION F ROOF INSULATION PER ENERGY DOCUMENTATION EXT. WALL INSULATION PER ENERGY DOCUMENTATION EXT. WALL RIGID INSULATION PER ENERGY DOCUMENTATION R-19 FIB. BATT INSUL ATION R-30 FIB. BATT INSUL ATION SUSPENDED T-BAR CEILING R-13 FIB. BATT INSUL ATION CONC. SLAB / FOOTING PER ENG. 42" H . STEEL GUARDRAIL A.D.A. LIF T T O CONTROL ROOM T.P.O. ROOF ING OV ER SHAPED FOAM PER R OOF PLAN WOOD FRAMED SEATING PLATFORM PER ENG. RECESS CONC. FLOOR W/ BUIL T-UP PLY STAGE PER THEATRE DNA DRAWINGS STE EL SPIRAL STAIR- CONTROL ROOM / CATWALK ACCESS ONLY STA CKED TERRA COTTA ROOF TILES IN PARAPET O PENING POWDER COA TED ALUMINUM AWNING CAT WALKS PER THEATRE D NA & STRUCT. DRAWINGS 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 SECTION NOTES SECTIONS DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-8.2SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" SCALE: 1 /4"=1'-0" 30" X 48" EXTERIOR AREA OF RESCUE- ONE REQUIRED FOR <200 OCCUPANTS PER FLOOR 30" X 48" CLEAR SPACE IN FRONT OF DRINKING FOUNTA IN KITCHEN CLEARANCES PER FIG. 11B-804.2.2 S HEET A-10 WATER CLOSET, SINK W/ SINGLE SERVICE SOAP , HAND DRYING FIXTUR E, AND GRAB BARS PER ACCESSIBILITY DETAILS SHEET A-1 0, FIGS. 11-B-604.3.1, 11B-60 4.5.2, 11B-604.5.1, SINK MOUNTING SPECS, SINGLE OCCUPANCY TOILET TIGHT-FITTING, SELF CLOSING DOOR W/ UNISEX ACCES SIBILITY SIGNAGE PER ACCESSIBILIT Y DE TAILS SHEET A-10 DOOR SWING CLEARANCES PER ACCE SSIBILITY DE TAILS SHEET A-10 FIGS. 11B-404.2.4.1 48" MIN. WIDE CLEAR PATH OF TRAVEL TO PUBLIC RIGHT OF WAY, COORDINATE WITH SITE PLAN 12 " PATH THROUGH COMMON R OW PER CBC 1029.8.1 LIMITED ACCES S SPACES PER CBC 1 1B-203.4 FRO NT LOADED STALL PER ACCESSIBILITY DETAILS SHEET A-1 0 FIG. 11B-604.8.1.3 (A) AMBULATORY ACCESSIBLE TOILET COM PARTMENT P ER ACCESSIBILITY DETAILS SHEET A- 10 FIG. 11B-604.8.2 STA NDARD TOILET STALL 30" X 60" CLEAR INSIDE WALL MO UNTED URINAL PER AC CESSIBILITY DETAILS SHEET A-10 FIG. 11B-605.2 (A). PROVIDE MIN. 30" X 48" CLR. FLOOR SPACE WALL MO UNTED SINK PER ACCES SIB ILITY DETAILS SHEET A-10 SINK MOUNTING SP ECS. PROVIDE MIN. 30" X 48" CLR. FL OOR SPACE 60" MIN. DIA. TURNAROUND SPACE. MAY O VERLAP DO OR SWING UP TO 12". ROLL UP DOOR PER SCHEDULE PORTABLE, RECONFIGU RABLE SE ATING MODULES SPIRAL STAIRS T O ACCESS CONTROL ROOM, LIG HTING, CATWALKS ELECTRIC PLATF ORM LIFT PER FIG. 11B-41 0.6 SHEET A-10 REMOVABLE SEATS TO PROVIDE 2X 33"X48" WHEELCHAIR SPACES UNISEX RES TROOM DOOR AND WALL SIGNAG E PER DETAIL SHEET A -10 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 1919 2020 2121 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 1919 2020 2121 ADA/EXITING NOTES 2121 99 1414 1414 1414 1414 774 FT.1 3' 13'20'18'25'24'2'3' 88 88 88 88 2020 2020 EXITING P LAN EXITING PLAN DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-9SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" ACCESSIBI LITY DETAILS DESCRIPTION:BY: BRYCE ENGSTROM Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-10SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CABRAILLE PER CODE UNISEX RESTROOM DOOR SIGNAGE SUBSTITUTE MEN'S / WOMEN'S SIGNS AS APPROPRIATE FOR MULTIPLE ACCOMMODATION RESTROOMS common law copyright and other property rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-11SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 1 /4"=1'-0" * NOTE: ALL PERF ORMANCE SPACE LIGHTIN G PER TH EATER DNA PL ANS REFLECDTED CEILING PLAN- 2ND FLOOR DESCRIPTION:BY: BRYCE ENGSTROM ARCHITECTAll of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-11 .1SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CAEXTERIOR SCONCES PER PLANS NOTE: THIS FIXTURE IS ALSO USED ON THE INTERIOR PER PLANS DAL TILE COLOR WHEEL COLLECTION-LIN EAR, 0161 LT. POLISHED URBAN PUTTY 4.25X8.25, HORIZON TAL OFFSET LAYOUT TO 48" ABV. F.F., USE SCHLUTER METAL COVE BASE, TOP, AND VERT. CORNER S. KOHLER HIGH CLIFF K-96057 W/ SLO AN TOUCHLESS FLUSHOMETER STAINLESS STEEL GRAB BAR S PER ADA DETAILS SHEET A-10 KOHLER PINOIT K-2035-1 WHITE, MOU NTING HEIGHTS AND CLEARANCES PER ADA DETAILS SHEET A-10 KOHLER HONESTY K-99760-4 CHROME BRADLEY 130 RECESSED MIRROR , SOAP & TOWEL DISPEN SER 34" H. COUNTERTOP LIGHTED MIRRO R FRON T LOAD ELECTRIC WASH ER FRON T LOAD ELECTRIC CLOTHES DRYER FREEDOM ADA COMPLIANT FIBERGLASS ROLL-IN SHOWER 30" WIDE FRIDGE/FREEZER 36" WIDE FRIDGE/FREEZER DEEP STAIN LESS SINK W/ CO MMERCIAL SPRAYER HIGH SPEED CO MMERCIAL D ISHWASHER MIC ROWAVE-HOOD COMBO ELECTRIC IN DUCTION RANGE 65 INCH FLAT SCREEN SMART TV DARK WALNUT FRAME GLASS DOOR C ABINETS ICE BIN UNDER C ABINET GLASS DOO R COOLER BRUSHED ALUMINUM STANDO FF LETTERS BEER TAPS OPEN SPACE OPEN SHELVING SPACE FOR TRASH RECEPTACLE 42" H. BAR TO P WITH DRINK RAIL 34" H. SERVIC E COUNTER SEMI-GLOSS LATEX PAINT TBD WALL MOUNTED VANITY CO UNTERTOP. MOUNTING H EIGHTS AN D CLEARANCES PER DETAILS SHEET A-10 KOHLER K-8637 TOUCHLESS SOAP DISPENSER KOHLER STRAYT K-104S37 SAN A TOU CHLESS FAUCET BRADLEY MODEL 155 RECESSED MIRR OR AND PAPER TOWEL DISPENSER DAL TILE COLOR WHEEL COLLECTION LINEAR, 3 COLORS RANDOM- (0161 LT. POLISHED URBAN PUTTY 4.25X8.25, 0180 LY. POLISH ED CHALK BOARD 4.25X13, K711 MATTE BLACK 4.25X13) TO TOP OF DOOR TRIM, SCH LUTER METAL COVE, BASE, TOP, AND VERTICAL CORNERS. POWDER CO ATED METAL STALL PARTITIONS TBD KOHLER BARDO N K-4991-ET W/ SLOAN TO UCHLESS FLUSH-O-METER 75 INCH FLAT SCREEN SMART TV HIGH BACK UPHO LSTERED BENCH- CONSULT IN TERIOR DESIGNER DARK WALNUT FRAMED PANELING TO 128" ABV. F.F. 1-1/2" X 12" DARK WALN UT COUNTER- 34" F.F. TO TOP STEEL SPIRAL STAIR ACCESS TO CON TR OL R OOM 42" H. STEEL CATWALK A.D.A. ELECTRIC CONTR OL R OOM ACCESS LIFT COLLAPSIBLE, RECO NFIG URABLE SEATS AND SEATIN G PLATFOR MS SCULPTED ACOUSTICAL WALL PANELING 1X4 STRAIGHT GRAIN D.F. WOOD SLATS ON WALL STANDOFFS AND 1/4" GAPS BETWEEN ALVA TESS WALL SCONCE PER SPECS SHEET A-11.1 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 1919 2020 2121 2222 2323 2424 2525 2626 2727 2828 2929 3030 3131 3232 3333 3434 3535 3636 3737 3838 3939 4040 4141 4242 4343 4444 4545 4646 4747 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 1919 2020 2121 2222 2323 2424 2525 2626 2727 2828 2929 3030 3131 3232 3333 3434 3535 3636 3737 3838 3939 4040 4141 4242 4343 4444 4545 4646 4747 INTERIOR ELEVATION NOTES 3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-12SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0" SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0" SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0" SCALE: 3 /8"=1'-0" SCALE: 3 /8"=1'-0" SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0" SCALE: 3 /8"=1'-0" rightsreserve this document as an original and unpublishedwork product of Bryce Engstrom: Architect, and thiswork shall not be duplicated, copied, disclosed, orused in connection with any other work or projectother than the specific product for which it has beenprepared or assigned to any third party, withoutexpress written consent of Bryce Engstrom:ArchitectARCHITECT:BRYCE ENGSTROM210 TRAFFIC WAY SUITE EARROYO GRANDE, CA 93420(805) 235-3385SHEET:REVISION TABLENUMBERDATEREVISED BYDESCRIPTIONOWNER:SAN LUIS OBISPO REPERTORYTHEATRE888 MORRO STREETSAN LUIS OBISPO, CA 93401(805) 786-2440A-12 .1SAN LUIS OBISPOREPERTORY THEATREMONTEREY STREETSAN LUIS OBISPO, CASCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0" SCALE: 3 /8"=1'-0"SCALE: 3 /8"=1'-0" SCALE: 1” – 10’-0” @ 30” x 42” SHEET SIZE 05'10'10' 20' 30' Scale: 1" = 10'-0" NORTH: Conceptual Landscape Plan SAN LUIS OBISPO REPERTORY THEATRE L-1 April 7, 2022 File Path: firma_SLO Repertory Theatre_21803 Last Date Modified: 040622 firma l a n d s c a p e a r c h i t e c t s p l a n n i n g • e n v i r o n m e n t a l s t u d i e s 187 Tank Farm Road, Suite 230, San Luis Obispo, CA 93401 phone: 805.781.9800 fax: 805.781.9803 SOLAR PANEL ARRAY ON PARKING STRUCTURE, REFER TO WATRY DESIGN PLANS April 7, 2022NORTH: L-2 May 23, 20188'24'04'8' 16' SCALE: 1/8" = 10'-0" NORTH:firma l a n d s c a p e a r c h i t e c t s p l a n n i n g • e n v i r o n m e n t a l s t u d i e s 187 Tank Farm Road, Suite 230, San Luis Obispo, CA 93401 phone: 805.781.9800 fax: 805.781.9803 Conceptual Landscape Plan SAN LUIS OBISPO REPERTORY THEATRE PLANT PALLETTE: LANDSCAPE SITE PLAN LEGEND: LANDSCAPE ZONE 1 Landscape Planter areas around The buildings and parking structure . LANDSCAPE ZONE 2 Landscape buffer zone adjacent to neighboring residential property. LANDSCAPE ZONE 3 Container Plants, freestanding ceramic pots. HARDSCAPE 1 Porcelain tile or decorative concerte Fields HARDSCAPE 2 Decorative paver band, plank style paver. PUBLIC RIGHT OF WAY Per City of San Luis Obispo Standards File Path: firma_SLO Repertory Theatre_21803 Last Date Modified: 04062022 Conceptual Landscape Plan SAN LUIS OBISPO REPERTORY THEATRE L-28'24'04'8' 16' SCALE: 1/8" = 1'-0" 8' SCALE: 1/8” – 1’-0” @ 30” x 42” SHEET SIZEfirma l a n d s c a p e a r c h i t e c t s p l a n n i n g • e n v i r o n m e n t a l s t u d i e s 187 Tank Farm Road, Suite 230, San Luis Obispo, CA 93401 phone: 805.781.9800 fax: 805.781.9803 Avoid cutting undergroundutility lines. It's costly.CallOR1-800-642-2444Call before you D gEXISTING UTILITY LOCATIONS SHOWN HERON ARE APPROXIMATE ONLY. IT SHALL BE THECONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTALLOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION.NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THEENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN IN THEIR PROPERLOCATION.DISCLAIMER NOTE:GENERAL NOTES1.NO CONSTRUCTION SHALL BE STARTED WITHOUT PLANS APPROVED BY THE CITY BUILDINGDEPARTMENT. THE BUILDING DEPARTMENT SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TOSTARTING OF CONSTRUCTION AND OF THE TIME LOCATION OF THE PRECONSTRUCTIONCONFERENCE. ANY CONSTRUCTION PERFORMED WITHOUT APPROVED PLANS OR PRIORNOTIFICATION TO THE BUILDING DEPARTMENT WILL BE REJECTED AND WILL BE AT THECONTRACTOR’S AND/OR OWNER’S RISK.2.FOR ANY CONSTRUCTION PERFORMED THAT IS NOT IN COMPLIANCE WITH PLANS OR PERMITSAPPROVED FOR THE PROJECT THE CITY BUILDING DEPARTMENT MAY REVOKE ALL ACTIVEPERMITS AND RECOMMEND THAT CITY CODE ENFORCEMENT PROVIDE A WRITTEN NOTICE ORSTOP WORK ORDER.3.ALL CONSTRUCTION WORK AND INSTALLATIONS SHALL CONFORM TO THE MOST CURRENTCITY OF SAN LUIS OBISPO BUILDING DEPARTMENT STANDARDS AND ALL WORK SHALL BESUBJECT TO THE APPROVAL OF THE BUILDING DEPARTMENT.4.THE PROJECT OWNER AND CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND/ORMAINTAINING ALL WEATHER ACCESS AT ALL TIMES TO EXISTING PROPERTIES LOCATED IN THEVICINITY OF WORK. ADDITIONALLY, THEY SHALL BE RESPONSIBLE FOR MAINTAINING ALLEXISTING SERVICES, INCLUDING UTILITY, GARBAGE COLLECTION, MAIL DISTRIBUTION, ETC, TOALL EXISTING PROPERTIES LOCATED IN THE VICINITY OF WORK.5.ON-SITE HAZARDS TO PUBLIC SAFETY SHALL BE SHIELDED BY CONSTRUCTION FENCING.FENCING SHALL BE MAINTAINED BY THE PROJECT OWNER AND CONTRACTOR UNTIL SUCHTIME THAT THE PROJECT IS COMPLETED AND OCCUPIED, POTENTIAL HAZARDS HAVE BEENMITIGATED, OR ALTERNATIVE PROTECTIVE MEASURES HAVE BEEN INSTALLED.6.SOILS TESTS SHALL BE DONE IN ACCORDANCE WITH THE CITY PUBLIC IMPROVEMENTSTANDARDS. TESTS MUST BE MADE WITHIN 15 DAYS PRIOR TO PLACING MATERIAL. THE TESTRESULTS SHALL CLEARLY INDICATE THE LOCATION AND SOURCE OF THE MATERIAL.7.ROADWAY COMPACTION TESTS SHALL BE MADE ON SUBGRADE MATERIAL, AGGREGATE BASEMATERIAL, AND MATERIAL AS SPECIFIED BY THE ENGINEER. SAID TESTS SHALL BE MADEPRIOR TO THE PLACEMENT OF THE NEXT MATERIAL LIFT.8.SUBGRADE MATERIAL SHALL BE COMPACTED TO A RELATIVE COMPACTION OF 95% IN THEZONE BETWEEN FINISHED SUBGRADE ELEVATION AND A MINIMUM OF ONE FOOT BELOW. ALLMATERIAL IN FILL SECTIONS BELOW THE ZONE MENTIONED ABOVE SHALL BE COMPACTED TO90% RELATIVE COMPACTION.9.A REGISTERED CIVIL ENGINEER SHALL CERTIFY THAT THE IMPROVEMENTS WHEN COMPLETEDARE IN ACCORDANCE WITH THE PLANS PRIOR TO THE REQUEST FOR A FINAL INSPECTION.RECORD DRAWINGS SHALL BE PREPARED AFTER CONSTRUCTION IS COMPLETED. THE CIVILENGINEER CERTIFYING THE IMPROVEMENTS AND PREPARING AS-BUILT PLANS MAY BEPRESENT WHEN THE FINAL INSPECTION IS MADE BY THE CITY .10.AN ENGINEER OF WORK AGREEMENT AND AN ENGINEER CHECKING AND INSPECTIONAGREEMENT ARE REQUIRED PRIOR TO THE START OF CONSTRUCTION. THE BUILDINGDEPARTMENT SHALL BE NOTIFIED IN WRITING OF ANY CHANGES TO THE ENGINEER OF WORKAGREEMENT. CONSTRUCTION SHALL NOT PROCEED WITHOUT AN ENGINEER OF WORK.11.ALL UTILITY COMPANIES SHALL BE NOTIFIED PRIOR TO THE START OF CONSTRUCTION.12.A CITY ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK DONE WITHIN THE CITYRIGHT-OF-WAY. THE ENCROACHMENT PERMIT MAY ESTABLISH ADDITIONAL UTILITY ANDTRAFFIC CONTROL REQUIREMENTS.13.THE CITY INSPECTOR ACTING ON BEHALF OF THE CITY BUILDING DEPARTMENT MAY REQUIREREVISIONS IN THE PLANS TO SOLVE UNFORESEEN PROBLEMS THAT MAY ARISE IN THE FIELD.ALL REVISIONS SHALL BE SUBJECT TO THE APPROVAL OF THE DEVELOPER’S ENGINEER OFWORK.14.HYDROSEEDING OR OTHER PERMANENT EROSION CONTROL SHALL BE PLACED ANDESTABLISHED WITH 90% COVERAGE ON ALL DISTURBED SURFACES (OTHER THAN PAVED ORGRAVEL SURFACES) PRIOR TO THE FINAL INSPECTION.15.FOR ANY PUBLIC IMPROVEMENTS TO BE MAINTAINED BY THE CITY , IF ENVIRONMENTALPERMITS FROM THE U.S. ARMY CORPS OF ENGINEERS, THE CALIFORNIA REGIONAL WATERQUALITY CONTROL BOARD/STATE WATER RESOURCES CONTROL BOARD, OR THE CALIFORNIADEPARTMENT OF FISH & GAME ARE REQUIRED, THE DEVELOPER SHALL:15.a.SUBMIT A COPY OF ALL SUCH COMPLETED PERMITS TO THE CITY BUILDING DEPARTMENTOR,15.b.DOCUMENT THAT THE REGULATORY AGENCIES DETERMINED THAT SAID PERMIT IS NOTREQUIRED;PRIOR TO ACCEPTANCE OF THE COMPLETED IMPROVEMENTS FOR CITY MAINTENANCE ANDRELEASE OF IMPROVEMENT SECURITY. ANY MITIGATION MONITORING REQUIRED BY SAIDPERMITS WILL REMAIN THE RESPONSIBILITY OF THE DEVELOPER.16.WHEN THE PROJECT SITE EARTHWORK IS NOT INTENDED TO BALANCE THEN A SEPARATEGRADING PERMIT FOR THE SENDING OR RECEIVING PROPERTY MAY BE REQUIRED. A COPY OFTHE PERMIT/S OR EVIDENCE THAT NO PERMITS ARE REQUIRED SHALL BE SUBMITTED TO THEDEPARTMENT PRIOR TO COMMENCING PROJECT EARTHWORK.PRO-ECT PRECONSTRUCTION 0EETINGPRIOR TO START OF CONSTRUCTION, A PRE-CONSTRUCTION MEETING SHALL BE SCHEDULED WITHTHE REPRESENTATIVE OF THE CITY OF SAN LUIS OBISPO, THE CIVIL ENGINEER OF RECORD, THESOILS ENGINEER OF RECORD, THE GRADING CONTRACTOR OF RECORD, THE OWNER/DEVELOPER,AND OTHERS REQUIRED TO IMPLEMENT AND TO SUPPORT THIS PROJECT. THE OWNER/DEVELOPERSHALL COORDINATE THIS MEETING WITH THE CITY REPRESENTATIVE AND OTHER PARTIES.OBSER9ATION AND TESTING PROGRA0THE SOILS ENGINEER OF RECORD SHALL OBSERVE THE FOLLOWING TASKS:1.PLACEMENT, BACKFILL, AND COMPACTION OF FILL MATERIALBI-WEEKLY REPORTS ARE REQUIRED BY THE SOILS ENGINEER OF RECORD TO THE GRADINGINSPECTOR, MONITORING THE JOB PROGRESS INCLUDING THE STATUS OF EROSION &SEDIMENTATION MONITORING.A FINAL REPORT IS REQUIRED FOR ENGINEERING GRADING INCLUDING ALL COMPACTIONREPORTS.PRO-ECT REPORT RE4UIRE0ENTSPAD CERTIFICATION REQUIREMENTA SOIL OR CIVIL ENGINEER SHALL DETERMINE GRADING PERFORMED FOR THIS PROJECT IS INSUBSTANTIAL CONFORMANCE WITH THE APPROVED PLANS AND IS SUITABLE TO SUPPORT THEINTENDED STRUCTURE(S). THE ENGINEER SHALL SUBMIT A FINAL REPORT TO THE CITY OF SANLUIS OBISPO.SOIL REPORT REQUIREMENTSTHE SOIL REPORT SL-16264-SA OBSERVATIONS AND RECOMMENDATIONS SHALL BE FOLLOWED.A REPRESENTATIVE OF THE GEOTECHNICAL SERVICES SHALL OBSERVE ALL APPLICATIONSREGARDING GENERAL GRADING, PAD GRADING, SLOPE CONSTRUCTION, UTILITY TRENCHESAND FOUNDATION CONSTRUCTION.GRADING NOTES1.ALL GRADING CONSTRUCTION SHALL CONFORM TO THE APPLICABLE CODES AS NOTED UNDER"APPLICABLE CODES" HEADING.2.THE DEVELOPER SHALL BE RESPONSIBLE FOR SCHEDULING A PRE-CONSTRUCTION MEETINGWITH THE CITY AND OTHER AFFECTED AGENCIES. THE CONTRACTOR SHALL NOTIFY THE CITYBUILDING DEPARTMENT AT LEAST 24 HOURS PRIOR TO ANY WORK BEING PERFORMED, ANDARRANGE FOR INSPECTION.3.GRADING SHALL COMPLY WITH THE RECOMMENDATIONS OF THE PRELIMINARY SOILS REPORT#SL-16264-SA BY EARTH SYSTEMS PACIFIC, INC. , DATE 4/21/2011 FILED WITH THE CITY OF SANLUIS OBISPO.4.SOILS ENGINEER TO DETERMINE THE SOIL IS SUITABLE TO SUPPORT THE INTENDED STRUCTURE.SUCH REPORT INCLUDING PROGRESS AND/OR COMPACTION REPORTS SHALL BE SUBMITTED TOTHE FIELD INSPECTOR PRIOR TO FINAL INSPECTION WHEN A SOILS REPORT IS OBTAINED. THECITY POLICY REGARDING PAD CERTIFICATION SHALL BE FOLLOWED. WHEN APPLICABLE THEENGINEER SHALL OBSERVE THE GRADING OPERATION(S) AND PROVIDE THE FIELD INSPECTORWITH REQUIRED COMPACTION REPORTS AND A REPORT STATING THAT THE GRADINGPERFORMED HAS BEEN OBSERVED AND IS IN CONFORMANCE WITH THE UBC AND CITYORDINANCES.5.NO CUT OR FILL SLOPES WILL BE CONSTRUCTED STEEPER THAN TWO HORIZONTAL TO ONEVERTICAL (2:1).6.DUST CONTROL IS TO BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION.7.AREAS OF FILL SHALL BE SCARIFIED, BENCHED AND RECOMPACTED PRIOR TO REPLACING FILLAND OBSERVED BY A SOIL OR CIVIL ENGINEER.8.FILL MATERIAL WILL BE RECOMPACTED TO 90% OF MAXIMUM DENSITY.9.REMOVE ANY DELETERIOUS MATERIAL ENCOUNTERED BEFORE PLACING FILL.10.ALL DISTURBED AREAS SHALL BE HYDRO SEEDED OR PLANTED WITH APPROVED EROSIONCONTROL VEGETATION AS SOON AS PRACTICAL AFTER CONSTRUCTION IS COMPLETE.11.MINIMUM SETBACK TO CREEKS AND BLUFFS SHALL BE MAINTAINED. MINIMUM SETBACK OF TWOFEET FROM ALL PROPERTY LINES WILL BE MAINTAINED FOR ALL GRADING.12.MINIMUM SLOPE AWAY FROM BUILDINGS SHALL BE 5% FOR THE FIRST TEN FEET AROUNDPERIMETER.13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURVEYMARKERS DURING CONSTRUCTION. ALL SUCH MONUMENTS OR MARKERS DISTURBED SHALL BERESET AT THE CONTRACTOR'S EXPENSE.14.ALL CONTRACTORS AND SUBCONTRACTORS WORKING WITHIN THE RIGHT OF WAY SHALL HAVEAN APPROPRIATE CONTRACTOR'S LICENSE, A LOCAL BUSINESS LICENSE, AND SHALL OBTAIN ANENCROACHMENT PERMIT.15.ENGINEERING REPORTS FOR CUT OR FILL SLOPES STEEPER THAN 2:1 SHALL BE SUBMITTED TOTHE FIELD INSPECTOR.UNDERGROUND UTILITY NOTES1.AN EFFORT HAS BEEN MADE TO DEFINE THE LOCATION OF UNDERGROUND FACILITIES WITHINTHE JOB SITE. HOWEVER, ALL EXISTING UTILITY AND OTHER UNDERGROUND STRUCTURESMAY NOT BE SHOWN ON THIS PLAN AND THEIR LOCATION WHERE SHOWN IS APPROXIMATE.THE CONSTRUCTION CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETERESPONSIBILITY FOR LOCATING OR HAVING LOCATED ALL UNDERGROUND UTILITIES ANDOTHER FACILITIES AND FOR PROTECTING THEM DURING CONSTRUCTION.2.ALL UTILITY COMPANIES MUST BE NOTIFIED PRIOR TO THE START OF CONSTRUCTION. THECONSTRUCTION CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT (USA) AT 811TWO TO TEN DAYS PRIOR TO THE START OF EXCAVATION AND SHALL VERIFY THE LOCATION OFANY KNOWN UTILITIES AND WHETHER OR NOT A REPRESENTATIVE OF EACH COMPANY WILL BEPRESENT DURING EXCAVATION.SPECIAL INSPECTIONS1.ALL CONSTRUCTION & INSPECTIONS SHALL CONFORM TO 2019 CALIFORNIA BUILDING CODE(CBC) CHAPTER 17.2.SPECIAL INSPECTION REQUIREMENT ARE REQUIRED FOR THIS PROJECT, THE OWNER ORREGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE OWNER'SAGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTIONSDURING CONSTRUCTION ON ALL TASKS IDENTIFIED BELOW.3.SPECIAL INSPECTORS SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATECOMPETENCE, TO THE SATISFACTION OF THE CITY BUILDING DEPARTMENT. NAMES ANDQUALIFICATIONS OF SPECIAL INSPECTOR(S) SHALL BE SUBMITTED TO THE CITY BUILDINGDEPARTMENT FOR APPROVAL.4.EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF COMPONENTS LISTED IN THESPECIAL INSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE CITYBUILDING DEPARTMENT AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK. THESTATEMENT SHALL CONTAIN THE ITEMS LISTED IN CBC 1706.1.5.A FINAL REPORT PREPARED BY A SOIL OR CIVIL ENGINEER SHALL BE SUBMITTED TO THE FIELDINSPECTOR STATING THE WORK PERFORMED IS IN SUBSTANTIAL CONFORMANCE WITH THEAPPROVED PLANS, APPLICABLE CODES, AND IS FOUND TO BE SUITABLE TO SUPPORT THEINTENDED STRUCTURE. SUCH REPORT SHALL INCLUDE ANY FIELD PROGRESS REPORTS,COMPACTION DATA ETC.SECTION 1705, STATEMENT OF SPECIAL INSPECTIONS:·1705.1 GENERAL. WHERE SPECIAL INSPECTION OR TESTING IS REQUIRED BY SECTION 1704,1707 OR 1708, THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALLPREPARE A STATEMENT OF SPECIAL INSPECTIONS IN ACCORDANCE WITH SECTION 1705 FORSUBMITTAL BY THE PERMIT APPLICATION (SEE SECTION 1704.1.1).·1705.2 CONTENT OF STATEMENT OF SPECIAL INSPECTIONS. THE STATEMENT OF SPECIALINSPECTIONS SHALL IDENTIFY THE FOLLOWING:a.THE MATERIALS, SYSTEMS, COMPONENTS AND WORK REQUIRED TO HAVE SPECIALINSPECTION OR TESTING BY THE BUILDING OFFICIAL OR BY THE REGISTERED DESIGNPROFESSIONAL RESPONSIBLE FOR EACH PORTION OF THE WORK.b.THE TYPE AND EXTENT OF EACH SPECIAL INSPECTION.c.THE TYPE AND EXTENT OF EACH TEST.d.ADDITIONAL REQUIREMENTS FOR SPECIAL INSPECTION OR TESTING FOR SEISMIC OR WINDRESISTANCE AS SPECIFIED IN SECTION 1705.3, 1705.4, 1707 OR 1708.e.FOR EACH TYPE OF SPECIAL INSPECTION, IDENTIFICATION AS TO WHETHER IT WILL BECONTINUOUS SPECIAL INSPECTION OR PERIODIC SPECIAL INSPECTION. SECTION (TABLE) 1704.7, REQUIRED VERIFICATION AND INSPECTION OF SOILS.a.VERIFY MATERIALS BELOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARINGCAPACITY SHALL BE PERFORMED PERIODICALLY DURING TASK.b.VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPERMATERIAL, SHALL BE PERFORMED PERIODICALLY DURING TASK.c.PERFORM CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIALS, SHALL BEPERFORMED PERIODICALLY DURING TASK.d.VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENTAND COMPACTION OF CONTROLLED FILL, SHALL BE PERFORMED CONTINUOUSLY DURINGTASK.e.PRIOR TO PLACEMENT OF CONTROLLED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HADBEEN PREPARED PROPERLY, SHALL BE PERFORMED PERIODICALLY DURING TASK.OBSERVATION & TESTING PROGRAM.THE PROJECT SOILS ENGINEER SHALL PERFORM THE INSPECTION & TESTING FOR THEFOLLOWING TASKS:·FINAL PLANS·STRIPPING AND CLEARING OF VEGETATION·RECOMPACTION OF SCARIFICATION SOILS·FILL PLACEMENT AND COMPACTION·OVER EXCAVATING·VERIFICATION OF SOILS TYPE & DEPTH·FINAL REPORTTHE SOIL ENGINEER OF WORK SHALL BE EARTH SYSTEMS PACIFIC, INC. SOILS REPORT#SL-16264-SA THE PROJECT ENGINEER OF WORK SHALL PERFORM THE INSPECTION FOR THEFOLLOWING TASKS:·ROUGH GRADING & SITE PREPARATION·FINAL GRADING INSPECTION PRIOR TO FINAL CITY INSPECTIONTHE PROJECT ENGINEER OF WORK SHALL BE DANIEL SOTELO OF ENGINEERING DESIGNPROFESSIONALS, INC., RCE 81227, P.O. BOX 4456, SAN LUIS OBISPO, CA 93403, PHONE (805)602-6167THE ENGINEER OR WORK SHALL STATE IN WRITING THE WORK IS IN SUBSTANTIALCONFORMANCE WITH THE APPROVED PLANS.PRO-ECT SUR9EY 0ONU0ENTSEXISTING SURVEY MONUMENTS SHALL BE TIED OUT OR REPLACED IN ACCORDANCE WITHCITYSTANDARDS AND SPECIFICATIONSGRADING AND 9EGETATION RE0O9ALTO CONTROL EROSION, ACTUAL GRADING SHALL BEGIN WITHIN 30 DAYS OF VEGETATION REMOVALOR THAT AREA SHALL BE PLANTED. NO VEGETATION REMOVAL OR GRADING WILL BE ALLOWEDWHICH WILL RESULT IN THE SILTATION OF WATER COURSE OR UNCONTROLLABLE EROSION.GROUND PREPARATIONPREPARATION OF GROUND FOR FILL. THE GROUND SURFACE SHALL BE PREPARED TO RECEIVEFILL BY THE REMOVAL OF TOPSOIL AND OTHER UNSUITABLE MATERIALS AS DETERMINED BY THESOILS ENGINEER.PREPARATION OF THE GROUND. THE GROUND SURFACE SHALL BE PREPARED TO RECEIVE FILL BYREMOVING VEGETATION, NON-COMPLYING FILL, TOPSOIL AND OTHER UNSUITABLE MATERIALSSCARIFYING TO PROVIDE A BOND WITH THE NEW FILL.FILL MATERIAL PERMITTED. NO ORGANIC MATERIAL SHALL BE PERMITTED IN FILLS EXCEPT ASTOPSOIL USED FOR SURFACE PLANT GROWTH ONLY AND WHICH DOES NOT EXCEED 4 INCHES INDEPTH.EROSION CONTROL 0EASURESEROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES MUST BE IN PLACE ANDFUNCTIONALEART+:OR. 4UANTITIESAREA OF DISTURBANCE = 0.47 ACESTIMATED CUT: 1,266 CY±ESTIMATED FILL: 678 CY±NET: 588 CY± CUTMAX CUT: 13'MAX FILL: 9'NOTE: EXACT SHRINKAGE, CONSOLIDATION, AND SUBSIDENCE FACTORS AND LOSSES DUE TOCLEARING OPERATIONS ARE NOT INCLUDED. ESTIMATED EARTHWORK QUANTITIES ARE BASEDUPON THE DIFFERENCE BETWEEN EXISTING GROUND SURFACE AND PROPOSED FINISH GRADES,AS SHOWN ON THE PLAN, AND SHOULD VARY ACCORDING TO THESE FACTORS. THE CONTRACTORSHALL BE RESPONSIBLE FOR SITE INSPECTION AND QUANTITY TAKE OFF, AND SHALL BIDACCORDINGLY.APPLICABLE CODES·2019 CALIFORNIA BUILDING CODE·2019 CALIFORNIA ELECTRICAL CODE·2019 CALIFORNIA FIRE CODE·2019 CALIFORNIA PLUMBING CODE·2019 CALIFORNIA REFERENCE STANDARDS CODE·CITY STANDARD SPECIFICATIONS: CURRENT EDITION·CITY ENGINEERING STANDARDS: CURRENT EDITION·CITY FIRE CODE ORDINANCE·CITY LAND USE ORDINANCE·GRADING 2019 APPENDIX CHAPTER 33NOTE:IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR ORPERMITTEE TO CONTACT "UNDERGROUND SERVICE ALERT OFNORTHERN CALIFORNIA" BY PHONE AT 8-1-1 FORTY-EIGHT (48) HOURSPRIOR TO START OF CONSTRUCTION FOR LOCATION OF POWER,TELEPHONE, OIL AND NATURAL GAS UNDERGROUND FACILITIES.CONTRACTOR OR PERMITEE SHALL ALSO CONTACT THEAPPROPRIATE AGENCY FOR THE LOCATION OF CABLE T.V., WATER,SEWER, DRAINAGE OR UNDERGROUND FACILITIES.CITY OF SAN LUIS OBISPO NOTESA.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THEUTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENTEDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. (THE CURRENTADOPTED STANDARDS ARE DATED AUGUST 2020.)B.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK, OR DRIVEWAYAPPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKSDIRECTOR.C.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLICRIGHT-OF-WAY, WITHIN CITY EASEMENTS, OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORKREQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS,UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK,DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREETTREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTIONOR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY.D.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST A 48-HOURNOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION.E.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD ANDCONSTRUCTION DEBRIS AT THE END OF EACH DAY.F.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKSDEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE.G.ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT LESS THAN 2% SHALLHAVE FINAL GRADIENTS CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER PRIOR TO FINALINSPECTION APPROVALS.H.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUTBY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TOOCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS ANDPROFESSIONS CODE.I.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THESATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALLDEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES.J.ONE 15-GALLON STREET TREE IS REQUIRED FOR EACH 35 LINEAL FEET OF FRONTAGE ORFRACTION THEREOF. TREE SPECIES AND PLANTING REQUIREMENTS SHALL BE PER CITYENGINEERING STANDARDS.GEOTECHNICAL REPORTPROJECT No. SL-16264-SADATED: APRIL 21, 2011AS PREPARED BY:EARTH SYSTEMS PACIFIC, INC.TOPOGRAPHIC SURVEY PROJECT No. 2005512DATED: JUNE 2006AS PREPARED BY:RRM DESIGN GROUPBENCHMARKFLOOD ZONE INFORMATIONA PORTION OF THE PROPERTY LIES WITHIN ZONE X, AN AREA OUTSIDE OF 0.2% ANNUAL CHANCEOF FLOOD HAZARD PER FEMA PANEL NO. 06079C1068G, EFFECTIVE DATE 11/16/2012.A PORTION OF THE PROPERTY LIES WITHIN ZONE AE, AN AREA TO BE DETERMINED TO HAVE A 1%ANNUAL CHANCE OF FLOOD HAZARD, BASE FLOOD ELEVATION OF 188 PER FEMA PANEL NO.06079C1068G, EFFECTIVE DATE 11/16/2012.THE BENCHMARK FOR THIS SURVEY BEING A LEAD AND TACK ON THE WESTERLY CURB 50 FEET(15 m) NORTH OF THE NWC OF NIPOMO & DANA, ELEVATION BEING 190.00 FEET (57.910 m)TOP BACK CURBFINISH GRADEEDGE OF PAVEMENTFLOW LINEASPHALT CONCRETE(00.00)TC(00.00)EG(00.00)EP(00.00)FL(00.00)ACTOP BACK CURBEXISTING GROUNDEDGE OF PAVEMENTFLOW LINEASPHALT CONCRETEPROPOSEDEXISTING00.00TC00.00FG00.00EP00.00FL00.00ACLEGENDHIGH POINT00.00HP(00.00)TRW(00.00)TFTOP OF RET. WALLTOP OF FOOTERTOP OF RET. WALLTOP OF FOOTER00.00TRW00.00TF(0" CURB WHERE APPLIES)DATE: DRAFTER: CHECKED: SCALE:SHEETSHEET OF SHEETSDESCRIPTION:REV:DATE: E N G I E E R I N GN D E S GI N P R O F E S S I O N A L S ,I N C . L 0 S 0 S C A 0 5 .6 0 2 .6 1 6 7 |E D P I N C 0 R P O R A T E D .C O M 0 S 8 7/6/2022 DS DSC115 7/6/2022NTS NOTE SHEET SAN LUIS OBISPO REPERTORY THEATRE MONTEREY STREET SAN LUIS OBISPO, CA APN# 002-412-011 R EGISTE R E D PROFESSIONAL ENGINEERSTATE OF CALIFORN I A EXP.CIVILNO. 81227D A NI EL A. SOTELOPRELI0INARYARCH-0221-2022SITE DATAAPN No.002-412-011ACREAGE:0.89ZONINGO-HA ARCHITECTURAL REVIEW1/14/2020 B ARCHITECTURAL REVIEW - BASEMENT REMOVED3/22/2022 C ARCHITECTURAL REVIEW - LANDSCAPE REVISION4/20/2022 D ARCHITECTURAL REVIEW - 2ND SUBMITTAL7/6/2022 ABAN ABANDONAIP ABANDONED IN PLACEAGG AGGREGATEALT ALTERNATE ECA ANODE, GASACP ASBESTOS CEMENT PIPEAC ASPHALTIC CONCRETEAVE AVENUEBC BACK OF CURBBCR BACK OF CURB RADIUSBVC BEGINNING OF VERTICALCURVEBM BENCH MARKBDRY LINEBOUNDARY LINECATV CABLE TELEVISIONC-C CENTER TO CENTERCL CENTERLINECO CLEAN OUT, SEWERCOMM COMMERCIALCONC, PCC CONCRETECONST CONSTRUCTION ORCONSTRUCTCOR CORNERCMP CORRUGATED METAL PIPECSAP CORRUGATED STEEL ARCHPIPECSP CORRUGATED STEEL PIPEC&G CURB AND GUTTERCIP CAST IRON PIPECOL COLUMNCU YD, CY CUBIC YARDCU FT, CF CUBIC FEETCULV CULVERTCF CURB FACEDEPT DEPARTMENTDIA DIAMETERDWY DRIVEWAY ORIGINAL GROUNDDI DROP INLETESMT EASEMENTE/O EAST OFEP EDGE OF PAVEMENTEO EDGE OF OILE ELECTRICEM ELECTRIC METERELEV ELEVATIONEMBK EMBANKMENTECR END OF CURB RETURNEC END OF CURVEEVC END OF VERTICAL CURVEEXIST EXISTINGFT FEET OR FOOTFG FINISH GRADEFA FIRE ALARMFH FIRE HYDRANTFL FLOW LINEGALV GALVANIZEDGM GAS METERGR GAS PRESSURE REGULATORPL-G PLASTIC GASS-G STEEL GASGB GRADE BREAKGUT GUTTERHDWL HEADWALLIN INCHINT INTERSECTIONINV INVERTISL ISLANDJB JUNCTION BOXLOC LENGTH OF CURBLT LEFTLF LINEAR FEETMH MANHOLEMAX MAXIMUMMIN MINIMUMMON MONOLITHICN/O NORTH OFNTS NOT TO SCALEOC ON CENTEROG ORIGINAL GROUNDPVMT PAVEMENTPI POINT OF INTERSECTIONPRC POINT OF REVERSE CURVEPC POINT OF CURVEPT POINT OF TANGENCYPCC POINT OF COMPOUND CURVEPP POWER POLEP POWERPL PROPERTY LINEPROP PROPOSEDPB PULL BOXRP RADIUS POINTR RADIUSRR RAILROADREINF REINFORCEDRC REINFORCED CONCRETERCB REINFORCED CONCRETE BOXRCP REINFORCED CONCRETE PIPERELOC RELOCATERT RIGHTR/W RIGHT-OF-WAYRD ROADSS SANITARY SEWERSHT SHEETS/O SOUTH OFSW SIDEWALKSQ FT, SF SQUARE FOOTSQ YD, SY SQUARE YARDSTA STATIONSHPSTEEL HIGHPRESSURE PIPESD STORM DRAINSTD STANDARDSTRUCT STRUCTURAL ORSTRUCTURESURV SURVEYSL STREETLIGHTT TELEPHONETEMP TEMPORARYTBA TO BE ADJUSTEDTBR TO BE REMOVEDTC TOP OF CURBTP TOP OF PIPETS TRAFFIC SIGNALTSI TRAFFIC SIGNALINTERCONNECTTRANS TRANSITIONTYP TYPICALUG UNDERGROUNDVAR VARIABLEVERT VERTICALVC VERTICAL CURVEVG VALLEY GUTTERVCP VITRIFIED CLAY PIPEW WATERWM WATER METERW/O WEST OFYD YARDABBREVIATIONS NV (W)186.30 SUMP91 8 9 . 9 3 F G 201.07F S 200.94FS200.58FS200.81FG2 0 1 . 5 5 FS 2 0 1 . 1 1FS 199.80 TG190.80 SUMP18200.92FG200.64FS193.66FS2 0 1 . 2 5 F S 201.07FS190.16FS190.16F S 190.80FS2.1%200.90FS201.00FG201.00FG200.62F G200.41FS2.1%2 0 0 . 2 5 FS 2 0 0 . 2 4 FS 200.35FS200.64FS1.4%200.90FS19 1 . 8 1 FS 19 1 . 9 4 FS 19 1 . 2 2 FS 19 0 . 4 4 FS 19 0 . 1 1 FS 18 9 . 9 6 FS 18 9 . 9 6 FS191.54F S 19 1 . 2 0 FS 191.04FS19 0 . 8 2 FS 4.1%1 9 0 . 2 8 F S 190.07FS1 9 0 . 3 6 F S 1 9 0 . 2 0 F S 2.0%3.9%190.39FS1 9 0 . 6 8 F S 190.68F S 190.34FS190.34FS190.48FS190.05FS2.0%3.5%2.8%20 1 . 0 7 F S 20 1 . 0 7 F S 20 0 . 9 1 F S 2 0 0 . 9 1 F S 189.98 FS201.07FS193.43 FG 193 . 7 2 FG 19 3 . 1 0 F G 19 3 . 9 1 FG 200.94FG196.29FG2 0 0 . 9 4 F S 2.0%19 0 . 3 1 F S 200.95FS200 . 9 6 FS 200.96 FS 201.07FS511 FT511.5 FT201.22FS200.57FS200.35FS0.8%0.8%194.50 FL 193.29 TG191.29 INV75.0%2.0%195194194 201 E C3 189.93FG59 FT189.86 TG187.36 INV.200.5%19019020120120144201201 2 0 0 2001020 0 . 7 9 FL 20 0 . 4 7 FL 200.03FL10200.83FS200.83FS200.82FS10PG E TRANSFOR0ER BY OT+ERS 2 0 2 . 7 1 F S 200.55FS194.29FL194. 1 9 FL 2.0%1.7%200.26FS200.20FS13.4%15.0%3.9%9.7%200.99FG200.89FS5%MIN193.47FL8200.08 FL 17172.0%190.48 TG187.98 INV .20 F C3 17.3'1515152 0 0 . 8 1 T G 1 9 6 . 1 7 I N V . 2 0 200. 9 8 T G 197. 0 6 I N V . 20 20 0 . 8 2 T G 19 6 . 5 3 I N V . 20BENCHMARKEXISTING UTILITY LOCATIONS SHOWN HERON ARE APPROXIMATE ONLY. IT SHALL BE THECONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTALLOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION.NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THEENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN IN THEIR PROPERLOCATION.DISCLAIMER NOTE:Avoid cutting undergroundutility lines. It's costly.CallOR1-800-642-2444Call before you D gFF2% MINCONCRETE8" MIN5% MINFOR 10'BUILDING SLAB SECTIONGEOTECHNICAL REPORTEARTHWORKSSITE DATAPROJECT No. SL-16264-SADATED: APRIL 21, 2011AS PREPARED BY:EARTH SYSTEMS PACIFIC, INC.CUT = 1,266 CYFILL = 678 CYNET = 588 CY CUTAPN No.002-412-011ACREAGE:0.89ZONINGO-H1005SCALE: 1" =1010'TOPOGRAPHIC SURVEY PROJECT No. 2005512DATED: JUNE 2006AS PREPARED BY:RRM DESIGN GROUPFLOOD ZONE INFORMATIONA PORTION OF THE PROPERTY LIES WITHIN ZONE X, AN AREA OUTSIDE OF 0.2% ANNUAL CHANCEOF FLOOD HAZARD PER FEMA PANEL NO. 06079C1068G, EFFECTIVE DATE 11/16/2012.A PORTION OF THE PROPERTY LIES WITHIN ZONE AE, AN AREA TO BE DETERMINED TO HAVE A 1%ANNUAL CHANCE OF FLOOD HAZARD, BASE FLOOD ELEVATION OF 188 PER FEMA PANEL NO.06079C1068G, EFFECTIVE DATE 11/16/2012.THE BENCHMARK FOR THIS SURVEY BEING A LEAD AND TACK ON THE WESTERLY CURB 50 FEET(15 m) NORTH OF THE NWC OF NIPOMO & DANA, ELEVATION BEING 190.00 FEET (57.910 m)DATE: DRAFTER: CHECKED: SCALE:SHEETSHEET OF SHEETSDESCRIPTION:REV:DATE: E N G I E E R I N GN D E S GI N P R O F E S S I O N A L S ,I N C . L 0 S 0 S C A 0 5 .6 0 2 .6 1 6 7 |E D P I N C 0 R P O R A T E D .C O M 0 S 8 7/6/2022 DS DSC225 7/6/20221" = 10' GRADING PLAN SAN LUIS OBISPO REPERTORY THEATRE MONTEREY STREET SAN LUIS OBISPO, CA APN# 002-412-011 R EGISTE R E D PROFESSIONAL ENGINEERSTATE OF CALIFORN I A EXP.CIVILNO. 81227D A NI EL A. SOTELOPRELI0INARYARCH-0221-202213654DEEPENED FOOTING, MAX DEPTH PER PLAN (SEE STRUCTURALPLANS FOR DETAILS).CONSTRUCT RETAINING WALL, MAX WALL HEIGHT AND LENGTH PER WALLPLAN AND PROFILES, SHEET C3. (SEE STRUCTURAL PLANS FOR WALLDETAILING). CONTRACTOR TO PROVIDE ASPHALTIC WATER PROOFING,BACK OF WALL DRAIN, AND WEEPHOLES PER GEOTECHNICAL REPORT.CONTRACTOR TO PROVIDE EDGE PROTECTION WHERE REQUIRED PER CBCREQUIREMENTS.CONSTRUCT 4" CONCRETE OVER 4" TO 6" OF IMPORTED SAND OVER 18"TYPE II AGGREGATE BASE REINFORCED WITH NO. 3 BARS PLACED AT 24IN O.C. BOTH WAYS PER GEOTECHNICAL REPORT.8CONSTRUCT STAIRS PER CBC REQUIREMENTS.97CONSTRUCTION NOTES21011121613TRASH ENCLOSURE (SEE ARCHITECTURAL PLANS FOR DETAILS)PROTECT TREE PER CITY OF SLO STANDARD 77-1.03A (2) TREE PROTECTION1415RAISED PLANTER BED (SEE LANDSCAPE PLANS FOR DETAILS)DECORATIVE CONCRETE (SEE LANDSCAPE PLANS FOR DETAILS)GRASSCRETE (SEE LANDSCAPE PLANS FOR DETAILS)CONTRACTOR TO INSTALL REMOVABLE BOLLARDSCONSTRUCT FLOW LINE AS SHOWNBENCH (SEE LANDSCAPE PLAN FOR DETAILS)LEGENDPROPERTY BOUNDARYRIGHT OF WAYPROPERTY LINESECTION LINECENTER LINEEASEMENTEXISTING BACK OF CURBEXISTING FACE OF CURBEXISTING LIP OF CURBEXISTING MAJOR CONTOUR LINEEXISTING MINOR CONTOUR LINEEXISTING FENCEEXISTING EDGE OF SIDEWALKBUILDINGSCONCRETEBACK OF CURBFACE OF CURBCURB LIPFLOW LINEGRADE BREAKSAWCUTSIDEWALKSETBACKXXX(100)(101)||||||||||||||||||||||||||||||TOP BACK CURBFINISH GRADEEDGE OF PAVEMENTFLOW LINEASPHALT CONCRETE(00.00)TC(00.00)EG(00.00)EP(00.00)FL(00.00)ACTOP BACK CURBEXISTING GROUNDEDGE OF PAVEMENTFLOW LINEASPHALT CONCRETEPROPOSEDEXISTING00.00TC00.00FG00.00EP00.00FL00.00ACLEGENDHIGH POINT00.00HP(00.00)TRW(00.00)TFTOP OF RET. WALLTOP OF FOOTERTOP OF RET. WALLTOP OF FOOTER00.00TRW00.00TF(0" CURB WHERE APPLIES)INSTALL 12"X12" MIDSTATE CATCH BASIN WITH GRATE OR EQUIVALENTPER MANUFACTURERS SPECIFICATIONS. GRATE TO BE TRAFFIC RATEDNEAR DRIVEWAY LOCATIONS.ADS MANHOLE WITH GRATE COVER PER MANUFACTURER'SSPECIFICATIONS. MANHOLE AND GRATE TO BE TRAFFIC RATED NEARDRIVEWAY LOCATIONS.DECOMPOSED GRANITE (SEE ARCHITECTURAL PLANS FOR DETAILS)174" IRON CAST IRON PIPE18PHASE 2 - ADS MANHOLE19PHASE 2 - RETAINING WALL20PHASE 2 - 12X12 MIDSTATE CATCH BASINA ARCHITECTURAL REVIEW1/14/2020 B ARCHITECTURAL REVIEW - BASEMENT REMOVED3/22/2022 C ARCHITECTURAL REVIEW - LANDSCAPE REVISION4/20/2022 D ARCHITECTURAL REVIEW - 2ND SUBMITTAL7/6/2022LANDINGS (SEE ARCH PLANS FOR DETAILS) 0%MINSEAT WALL BENCH(SEE LANDSCAPE PLANS FOR DETAILS)2.0%FF=201.40BUILDINGFOUNDATION (BY OTHERS)EXISTING GRADEPARKING STRUCTURE - PHASE 2(BY OTHERS)FF 201.33PARKING STRUCTURE - PHASE 2(BY OTHERS)FF 190.16±25.5' ALLEY2.0%SECTION @ NORTH WESTNTSD13.9'11.6'FLFF=201.40BUILDINGPARKING STRUCTURE - PHASE 2(BY OTHERS)FF 201.33PARKING STRUCTURE - PHASE 2(BY OTHERS)FF 189.33FOUNDATION (BY OTHERS)EXISTING GRADE±1.5'6" CLASS II AGG BASESECTION @ NORTH WESTNTSERW1115.7'15.3'MONTEREY ST (PUBLIC)FRONTAGE IMPROVEMENTS - PHASE 3(BY OTHERS)PROPOSED GROUNDFF=201.40BUILDINGEXISTING GROUNDINSTALL STORMTECH MC-3500CHAMBERS W/ MANHOLE PERMANUFACTURER'S SPECIFICATIONS.SEE STORMTECH DETAIL 3, SHEET C4.INSTALL 30 MIL HDPE MOISTUREBARRIER LINER OR EQUIVALENTAT PERIMETER STONEINSTALL 30 MIL HDPE MOISTUREBARRIER LINER OR EQUIVALENTAT PERIMETER STONE20" STONE FOUNDATION DEPTHELEV. = 186.30 SUMPELEV. = 186.46 BOT. OF STONE FOUND.ELEV. = 188.13 BOT. OF CHAMBERELEV. = 188.30 24" INV.ELEV. = 191.88 TOP OF CHAMBERELEV. = 192.88 TOP OF STONESECTION @ STORM TECH CHAMBERSNTSFELEV. = 190.73 8" INV.1701801902002102202301701801902002102202300+801+001+50STA: 1+00.00 TOF ELEV: 199.90 BEGIN WALL STA: 1+27.37 TOF ELEV: 199.23 END WALL STA: 1+22.63 TOF ELEV: 199.90 STA: 1+22.63 TOF ELEV: 199.23 STEP FOOTING STA: 1+10.50 TOF ELEV: 199.90 AP STA: 1+00.00 TOW ELEV: 204.59 BEGIN WALL STA: 1+27.37 TOW ELEV: 204.59 END WALL GRADE AT FACE OF WALLGRADE AT BACK OF WALLBENCHMARKEXISTING UTILITY LOCATIONS SHOWN HERON ARE APPROXIMATE ONLY. IT SHALL BE THECONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTALLOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION.NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THEENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN IN THEIR PROPERLOCATION.DISCLAIMER NOTE:Avoid cutting undergroundutility lines. It's costly.CallOR1-800-642-2444Call before you D g1005SCALE: 1" =1010'FLOOD ZONE INFORMATIONA PORTION OF THE PROPERTY LIES WITHIN ZONE X, AN AREA OUTSIDE OF 0.2% ANNUAL CHANCEOF FLOOD HAZARD PER FEMA PANEL NO. 06079C1068G, EFFECTIVE DATE 11/16/2012.A PORTION OF THE PROPERTY LIES WITHIN ZONE AE, AN AREA TO BE DETERMINED TO HAVE A 1%ANNUAL CHANCE OF FLOOD HAZARD, BASE FLOOD ELEVATION OF 188 PER FEMA PANEL NO.06079C1068G, EFFECTIVE DATE 11/16/2012.THE BENCHMARK FOR THIS SURVEY BEING A LEAD AND TACK ON THE WESTERLY CURB 50 FEET(15 m) NORTH OF THE NWC OF NIPOMO & DANA, ELEVATION BEING 189.99 FEET (57.910 m)1FUTURE RETAINING WALL. SEE WALL PROFILES THIS SHEET FOR TOP OFWALL AND TOP OF FOOTING ELEVATIONS. CONTRACTOR TO PROVIDEBACK OF WALL ASPHALTIC WATER PROOFING, DRAIN ROCK, ANDPERFORATED PIPE PER GEOTECHNICAL REPORT. PERFORATED PIPE TODAYLIGHT. CONTRACTOR TO VERIFY WALL HEIGHT PRIOR TOCONSTRUCTION.CONSTRUCTION NOTESNOTE TO CONTRACTOR:1.FOOTING DEPTH ELEVATIONS ARE BASED ON THE MINIMUM DEPTH AS SPECIFIED BYTHE SOILS ENGINEER. FINAL FOOTING DEPTH SHALL BE DETERMINED BY THE SOILSENGINEER. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD WITH FINAL WALLDESIGN REQUIREMENTS PRIOR TO FOOTING CONSTRUCTION.2.SEE RETAINING WALL DETAIL X, ON SHEET XX FOR ADDITIONAL INFORMATION.RETAINING WALL 1 - PROFILE VIEWHORZ: 1" = 10'VERT: 1" = 10'RETAINING WALL 2 - PROFILE VIEWHORZ: 1" = 10'VERT: 1" = 10'(PHASE 2) RETAINING WALL 4 - PROFILE VIEWHORZ: 1" = 10'VERT: 1" = 10'DATE: DRAFTER: CHECKED: SCALE:SHEETSHEET OF SHEETSDESCRIPTION:REV:DATE: E N G I E E R I N GN D E S GI N P R O F E S S I O N A L S ,I N C . L 0 S 0 S C A 0 5 .6 0 2 .6 1 6 7 |E D P I N C 0 R P O R A T E D .C O M 0 S 8 7/6/2022 DS DSC335 7/6/20221" = 10' DETAIL SHEET SAN LUIS OBISPO REPERTORY THEATRE MONTEREY STREET SAN LUIS OBISPO, CA APN# 002-412-011 R EGISTE R E D PROFESSIONAL ENGINEERSTATE OF CALIFORN I A EXP.CIVILNO. 81227D A NI EL A. SOTELOPRELI0INARYARCH-0221-2022A ARCHITECTURAL REVIEW1/14/2020 B ARCHITECTURAL REVIEW - BASEMENT REMOVED3/22/2022 C ARCHITECTURAL REVIEW - LANDSCAPE REVISION4/20/2022 D ARCHITECTURAL REVIEW - 2ND SUBMITTAL7/6/2022 RETAINING WALL 3 - PROFILE VIEWHORZ: 1" = 10'VERT: 1" = 10' DATE: DRAFTER: CHECKED: SCALE:SHEETSHEET OF SHEETSDESCRIPTION:REV:DATE: E N G I E E R I N GN D E S GI N P R O F E S S I O N A L S ,I N C . L 0 S 0 S C A 0 5 .6 0 2 .6 1 6 7 |E D P I N C 0 R P O R A T E D .C O M 0 S 8 7/6/2022 DS DSC445 7/6/2022NTS DETAIL SHEET SAN LUIS OBISPO REPERTORY THEATRE MONTEREY STREET SAN LUIS OBISPO, CA APN# 002-412-011 R EGISTE R E D PROFESSIONAL ENGINEERSTATE OF CALIFORN I A EXP.CIVILNO. 81227D A NI EL A. SOTELOPRELI0INARYARCH-0221-2022CONC. FLOOR SLABF.F. ELEV. PER PLANTYPICAL DOWNSPOUT TIE INNTS1DOWNSPOUT ADAPTORINSERTED IN RISER PIPECLEANOUT WITH ENDCAP ADJUST RIMELEVATION PER PLAN6" SDFINISH GRADESTORM DRAINPIPE PER PLAN.INV ELEVATIONPER PLAN.90° ELBOW45° BEND45° WYEHDPE PIPE (TYP.)NOTES:1.ALL PIPES/FITTINGS LOCATED WITHIN 5 FEET OF FOUNDATION SHALL BE WATER TIGHT2.ALL PIPES/FITTINGS LOCATED WITHIN OR ABOVE FOUNDATION ZONE OF INFLUENCE SHALL BE WATERTIGHT. CONTRACTOR TO VERIFY ZONE OF INFLUENCE LOCATION WITH GEOTECHNICAL ENGINEERPRIOR TO CONSTRUCTION3.ALL PIPES/FITTING SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS4.DO NOT GLUE DOWNSPOUT ADAPTER TO STORM DRAIN RISER - USE SMALL AMOUNT OF LUBRICANT ORGREASE TO SEAL CONNECTION AND ALLOW FOR FUTURE ADAPTER5.CLEANOUTS, FITTINGS, AND PIPE TO BE TRAFFIC RATED IF LOCATED IN AREAS NEAR OR IN VEHICULARTRAFFICDOWNSPOUT (BY OTHERS)NOTES:1.NO TREES OR LARGE BUSHES ARE TO BE PLANTED OVER SEWER/STORM DRAIN PIPE2.NATIVE MATERIAL MAY SUFFICE FOR BEDDING AND INITIAL BACKFILL - SEE SOILS REPORT3.CONTRACTOR TO INSTALL PIPE PER MANUFACTURER'S SPECIFICATIONS4.CONTRACTOR TO VERIFY MANUFACTURER'S MIN COVER AND LOADING REQUIREMENTS PRIOR TO CONSTRUCTION5.ALL PIPES/FITTINGS LOCATED WITHIN OR ABOVE FOUNDATION ZONE OF INFLUENCE SHALL BE WATER TIGHT. CONTRACTORTO VERIFY ZONE OF INFLUENCE LOCATION WITH GEOTECHNICAL ENGINEER PRIOR TO CONSTRUCTIONS9" MAX DIA.FINISH GRADESTORM DRAIN/SEWER TRENCH (3" DIA. AND LARGER PIPES)NTS2LANDSCAPE TOPSOIL,WHERE OCCURSNATIVE MATERIAL@ 90% MIN R.C.CLEAN SAND@ 95% MIN R.C.3" MIN SAND COVER(HAND-TAMPED)3" MIN SAND COVER(HAND-TAMPED)NON-VEHICULAR AREASS9" MAX DIA.PAVEMENT SECTION PERGEOTECHNICAL REPORTTOP 12" @ 95% MIN R.C.NATIVE MATERIAL@ 90% MIN R.C.CLEAN SAND@ 95% MIN R.C.3" MIN SAND COVER(HAND-TAMPED)3" MIN SAND COVER(HAND-TAMPED)VEHICULAR AREASSTORM TECH UNDERGROUND DETENTION CHAMBERSNTS3A ARCHITECTURAL REVIEW1/14/2020 B ARCHITECTURAL REVIEW - BASEMENT REMOVED3/22/2022 C ARCHITECTURAL REVIEW - LANDSCAPE REVISION4/20/2022 D ARCHITECTURAL REVIEW - 2ND SUBMITTAL7/6/2022 PARKING METEREXISTING NO PARKING SIGNEXISTING WATER METEREXISTING CURB AND SIDEWALKEXISTING CURB AND SIDEWALKEXISTING DRIVEWAYEXISTING STREET LIGHTEXISTING ELECTRICAL VAULTEXISTING CURB GUTTER AND SIDEWALKEXISTING GATE VALVESEXISTING FIRE HYDRANTEXISTING SSMHRIM EL =(202.14)EXISTING 2.5'RETAINING WALLDRIP LINEDRIP LINE48" OAKEXISTING PARKING METEREXISTING POWER POLEEXISTING 2.5' RETAINING WALLEXISTING GATE VALVEEXISTING POWER POLEEXISTING STREET SIGNEXISTING CURB & SIDEWALKEXISTINGHANDICAPRAMPEXISTING CURB ANDSIDEWALKEXISTING CURB,GUTTER, ANDSIDEWALKEXISTING STREET TREEEXISTINGHANDICAPRAMPEXISTING SSCOEXISTINGWATER METEREXISTING GATE VALVEMONTEREY STREETDANA STREETEXISTING SSMHRIM EL = 191.85NIPOMO STREET N36° 28' 51"W 279.70'N53° 05' 37"E 214.61'S36° 15' 10"E 281.64'(PUBLIC)(PUBLIC)(PUBLIC)2.43'BUILDINGFF PROPOSED T+EATER60' RW30' RW30' RWLI0ITS OF  YR FLOOD PLAINLI0ITS OF  YR FLOOD PLAINLI0ITS OF  YR FLOOD PLAINLINE OF DECK ABOVELINE OF STAIRS ABOVE0.5'1200.00 TG194.56 INV.1200.66 TG194.75 INV.2200.63 RIM193.96 INV.2197.31 RIM190.77 INV.3195.55 TG189.50 INV. (NW)189.50 INV.(SW)188.30 INV. (NE)190.73 INV. (SE)186.30 SUMP12910101213.5'15.3'31.2'9  CF10.9' 8.5' 7.0'22.1'6193.64 INV.6190.31 INV.1193.29 TG191.29 INV.1026 LF 8" SD @ 8.63%23 LF 8" SD @ 3.88%108 LF 8" SD @ 3.67%7 LF 8" SD @ 2.05%1029 LF 8" SD @ 11.55%104 LF 8" SD @ 11.00%107 LF 8" SD @ 5.00%12388PAR.ING STRUCTURE  P+ASE  BY OT+ERS FRONTAGE IMPROVEMENTS - PHASE 3(BY OTHERS)FRONTAGE IMPROVEMENTS - PHASE 3 (BY OTHERS)1148.1'3 LF 4" SD @ 3.33%194.29 INV.194.19 INV.106 LF 8" SD @ 11.52%5189.64 INV.(ROOF AREA TODRAIN TO BASIN 2)(ROOF AREA TODRAIN TO BASIN 2)6190.73 INV.7193.30 INV.7192.41 INV.103 LF 8" SD @ 16.65%107 LF 8" SD @ 16.65%4102 LF 8" SD @ 16.65%3 LF 4" SD @ 1.67%200.08 INV.200.03 INV.194.43 INV.BENCHMARKEXISTING UTILITY LOCATIONS SHOWN HERON ARE APPROXIMATE ONLY. IT SHALL BE THECONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTALLOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION.NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THEENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN IN THEIR PROPERLOCATION.DISCLAIMER NOTE:Avoid cutting undergroundutility lines. It's costly.CallOR1-800-642-2444Call before you D gFF2% MINCONCRETE8" MIN5% MINFOR 10'BUILDING SLAB SECTIONGEOTECHNICAL REPORTSITE DATAPROJECT No. SL-16264-SADATED: APRIL 21, 2011AS PREPARED BY:EARTH SYSTEMS PACIFIC, INC.APN No.002-412-011ACREAGE:0.89ZONINGO-H1005SCALE: 1" =1010'TOPOGRAPHIC SURVEY PROJECT No. 2005512DATED: JUNE 2006AS PREPARED BY:RRM DESIGN GROUPFLOOD ZONE INFORMATIONA PORTION OF THE PROPERTY LIES WITHIN ZONE X, AN AREA OUTSIDE OF 0.2% ANNUAL CHANCEOF FLOOD HAZARD PER FEMA PANEL NO. 06079C1068G, EFFECTIVE DATE 11/16/2012.A PORTION OF THE PROPERTY LIES WITHIN ZONE AE, AN AREA TO BE DETERMINED TO HAVE A 1%ANNUAL CHANCE OF FLOOD HAZARD, BASE FLOOD ELEVATION OF 188 PER FEMA PANEL NO.06079C1068G, EFFECTIVE DATE 11/16/2012.THE BENCHMARK FOR THIS SURVEY BEING A LEAD AND TACK ON THE WESTERLY CURB 50 FEET(15 m) NORTH OF THE NWC OF NIPOMO & DANA, ELEVATION BEING 189.99 FEET (57.910 m)DATE: DRAFTER: CHECKED: SCALE:SHEETSHEET OF SHEETSDESCRIPTION:REV:DATE: E N G I E E R I N GN D E S GI N P R O F E S S I O N A L S ,I N C . L 0 S 0 S C A 0 5 .6 0 2 .6 1 6 7 |E D P I N C 0 R P O R A T E D .C O M 0 S 8 7/6/2022 DS DSC555 7/6/20221" = 10' UTILITY PLAN SAN LUIS OBISPO REPERTORY THEATRE MONTEREY STREET SAN LUIS OBISPO, CA APN# 002-412-011 R EGISTE R E D PROFESSIONAL ENGINEERSTATE OF CALIFORN I A EXP.CIVILNO. 81227D A NI EL A. SOTELOPRELI0INARYARCH-0221-202212ADS MANHOLE WITH GRATE COVER PER MANUFACTURER'SSPECIFICATIONS. MANHOLE AND GRATE TO BE TRAFFIC RATED INDRIVEWAY LOCATIONS.3INSTALL STORMTECH MC-3500 CHAMBERS W/ MANHOLE PERMANUFACTURERS SPECIFICATIONS. SEE STORMTECH DETAIL 3,SHEET C4.4567STORM DRAIN CONSTRUCTION NOTESINSTALL 12"X12" MIDSTATE CATCH BASIN WITH GRATE OR EQUIVALENTPER MANUFACTURERS SPECIFICATIONS. GRATE TO BE TRAFFIC RATEDNEAR DRIVEWAY LOCATIONS.CONNECT ROOF DRAINS TO ADS EXPANDABLE DOWNSPOUT ADAPTERWITH CLEAN OUT OR EQUIVALENT PER MANUFACTURER'SSPECIFICATIONS AND TYPICAL DOWNSPOUT DETAIL 1, SHEET C4.INSTALL 8"X8" ADS-N12 WT HDPE STORM DRAIN PIPE TEE OREQUIVALENT PER MANUFACTURE'S SPECIFICATIONS.INSTALL 8" ADS-N12 WT HDPE STORM DRAIN PIPE 45° ELBOW OREQUIVALENT PER MANUFACTURE'S SPECIFICATIONS.INSTALL 8" ADS-N12 WT HDPE STORM DRAIN PIPE 90° ELBOW OREQUIVALENT PER MANUFACTURE'S SPECIFICATIONS.9CONNECT EMERGENCY OVERFLOW TO STORM DRAIN LATERAL12SEWER CONSTRUCTION NOTES6" PVC (SDR 35, OR EQUAL) GRAVITY SEWER LATERAL AT 2.0% MIN.SLOPE FROM POINT OF CONNECTION TO BUILDING, WITH END OF RUNSEWER CLEAN OUT W/TRAFFIC RATED LID PER CITY OF SLO SEWERLATERAL STANDARD DETAILS 6810, 6710, AND DETAIL 2, SHEET C4.6" PVC (SDR 35, OR EQUAL) SEWER CLEANOUT. CLEANOUT SHALLHAVE WELL W/TRAFFIC RATED LID PER CITY OF SLO SEWERCLEANOUT & WELL STANDARD DETAIL 6710 IN TRAFFIC LOCATIONS.3CONNECT TO FUTURE SEWER LATERAL. (LATERAL INVERT ELEVATIONBY OTHERS)84" CAST IRON PIPELEGENDPROPERTY BOUNDARYRIGHT OF WAYPROPERTY LINESECTION LINECENTER LINEEASEMENTEXISTING BACK OF CURBEXISTING FACE OF CURBEXISTING LIP OF CURBEXISTING MAJOR CONTOUR LINEEXISTING MINOR CONTOUR LINEEXISTING FENCEEXISTING EDGE OF SIDEWALKBUILDINGSCONCRETEBACK OF CURBFACE OF CURBCURB LIPFLOW LINEGRADE BREAKSAWCUTSIDEWALKSETBACKJOINT TRENCHWATERSTORM DRAINPHASE 2 - STORM DRAINSANITARY SEWERXXX(100)(101)||||||||||||||||||||||||||||||JTJTJTWWWSDSDSDSDSDSDA ARCHITECTURAL REVIEW1/14/2020 B ARCHITECTURAL REVIEW - BASEMENT REMOVED3/22/2022 C ARCHITECTURAL REVIEW - LANDSCAPE REVISION4/20/2022 D ARCHITECTURAL REVIEW - 2ND SUBMITTAL7/6/2022SSSSSSINSTALL 8" ADS-N12 WT HDPE STORM DRAIN PIPE PERMANUFACTURER'S SPECIFICATIONS AND DETAIL 2, SHEET C4.10PHASE 2 - STORMTECH CHAMBERS W/ MANHOLE AND STORMDRAIN LATERALS.12CONNECT TO PHASE 2 STORM DRAIN LATERAL STUB OUT.11