Loading...
HomeMy WebLinkAboutPRR26279 FilesFrom:Estrada, Ethan To:Building Subject:FW: 619 Grove St. Addition Date:Monday, August 11, 2025 4:51:59 PM Attachments:image002.png image003.png image004.png image005.png image006.png image007.png image008.png image007.png image005.png image002.png image004.png image003.png image006.png image008.png Good afternoon, Just in case John didn’t reach out to you all separately, but he has requested to withdraw BLDG-1538-2025 and to be refunded any remaining fees. Currently in discussions over a possible ADU application. Kind regards, Ethan Estrada Assistant Planner Community Development 919 Palm, San Luis Obispo, CA 93401-3218 E EJEstrad@slocity.org T 805.781.7576 slocity.org Stay connected with the City by signing up for e-notifications From: John Rourke < Sent: Saturday, August 9, 2025 10:58 AM To: Estrada, Ethan <EJEstrad@slocity.org> Cc: Kelly Campos < ; Christopher Allen <cwa.arch@gmail.com> Subject: Re: 619 Grove St. Addition Sorry forgot to reply to all We wouldn't propose the expansion/alteration of existing, we would create a new attached Adu with seperate entrance. Please cancel this application and refund remaining fees. On Thu, Aug 7, 2025, 5:11 PM Estrada, Ethan <EJEstrad@slocity.org> wrote: Unfortunately, in this case, it would not. Per SLOMC 17.86.020, applications that propose the expansion/alteration of an existing single-family dwelling for the purpose of creating an ADU is permissible, but said expansion/alteration must be consistent with all underlying zoning regulations. This is the section that was recently added to our zoning regulations that allow what originally required a “two-step” building permit process as a “one-step” process if the proposed addition/expansion is consistent with zoning regulations. To be consistent with the City’s regulations you will need to obtain a Director’s Action for the addition to a nonconforming structure. Kind regards, Ethan Estrada Assistant Planner Community Development 919 Palm, San Luis Obispo, CA 93401-3218 E EJEstrad@slocity.org T 805.781.7576 slocity.org Stay connected with the City by signing up for e-notifications From: John Rourke < Sent: Thursday, August 7, 2025 3:32 PM To: Estrada, Ethan <EJEstrad@slocity.org> Cc: Kelly Campos < ; Christopher Allen <cwa.arch@gmail.com> Subject: Re: 619 Grove St. Addition I'm assuming making it an ADU gets rid of that issue. I don't know why we bother doing anything but ADUs anymore, gets rid of most the issues. On Thu, Aug 7, 2025, 1:03 PM Estrada, Ethan <EJEstrad@slocity.org> wrote: Good afternoon, Kelly – As shown on Sheet AS1.1 (Architectural Site Plan), the existing residence is depicted to be within the 5-foot minimum side-yard setback along the northern property line. Per SLOMC 17.16.020(B), properties zoned R-1 require, at minimum, to be setback 5 feet from all side and rear property lines (setbacks increase depending on the height of the structure). Therefore, the existing residence is considered to be nonconforming with the underlying zoning regulations. John - Section 17.92.020 provides guidelines pertaining to the reconstruction (which includes modifications/additions) of structures considered nonconforming. Many of the subsections of 17.92.020 do pertain to the reconstruction of nonconforming structures involuntarily damaged because such scenarios are often the only instances where the City would allow a structure to be built/modified in such a way that would make it nonconforming (exceptions to that would be density bonus and flexible lot design projects). The intent of Chapter 17.92, as stated in 17.92.010, is to provide for the correction or removal of nonconforming structures as soon as practical, but not unduly encumber maintenance and continued use of otherwise sound structures. Subsection F of 17.92.020 offers the opportunity, via Director’s Action, to allow an addition to a structure that would otherwise be required to remedy the nonconforming aspect of the building, given that the applicable findings can be made. Kind regards, Ethan Estrada Assistant Planner Community Development 919 Palm, San Luis Obispo, CA 93401-3218 E EJEstrad@slocity.org T 805.781.7576 slocity.org Stay connected with the City by signing up for e-notifications From: John Rourke < Sent: Thursday, August 7, 2025 11:57 AM To: Kelly Campos < Cc: Estrada, Ethan <EJEstrad@slocity.org>; Christopher Allen <cwa.arch@gmail.com> Subject: Re: 619 Grove St. Addition Hi Ethan, The code your citing has to do with rebuilding a house that has been damaged 17.92.020 Limits on reconstruction—Exceptions. A. A nonconforming structure that is involuntarily damaged to an extent of seventy- five percent or more of its replacement cost immediately prior to such damage, as determined by the chief building official, may be restored only if made to conform. It is very common to do an addition to an existing house and I've never heard of a director approval being required to do so. Please remove this comment. Thanks John On Thu, Aug 7, 2025, 9:08 AM Kelly Campos < wrote: Apologies, the comment was made by Ethan Estrada. I have included Ethan. That being said, we are looking to get a better understanding of the following comment for BLDG -1538-2025: Mainly, why is the existing residence considered to be non-conforming? Thank you, Kelly M. Campos Designer CWA Studios On Thu, Aug 7, 2025 at 10:01 AM John Rourke < wrote: Please include Phil d, what make it non conforming On Thu, Aug 7, 2025, 8:57 AM Kelly Campos < wrote: Hey John, This comment from Phil D. stipulates that the existing structure is a non- conforming structure at 619 Grove St. Due to that, we need to obtain approval through the director's action. Please see the image below of the associated comment. Let us know how you would like to proceed. Thank you, Kelly M. Campos Designer CWA Studios CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 GENERAL INFORMATION 01 Project Name Grove Street Addition 02 Run Title Title 24 Analysis 03 Project Location 619 Grove Street 04 City San Luis Obispo 05 Standards Version 2022 06 Zip code 93401 07 Software Version EnergyPro 9.4 08 Climate Zone 5 09 Front Orientation (deg/ Cardinal)90 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Addition and/or Alteration 13 Number of Bedrooms 5 14 Addition Cond. Floor Area (ft2)715 15 Number of Stories 2 16 Existing Cond. Floor Area (ft2)1287 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)2002 19 Glazing Percentage (%)10.21% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr)Margin (EDR1)Margin (EDR2) Space Heating 0 67.05 0 65.21 0 1.84 Space Cooling 0 2.31 0 2.98 0 -0.67 IAQ Ventilation 0 0 0 0 0 0 Water Heating 0 40.35 0 40.35 0 0 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 0 109.71 0 108.54 0 1.17 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 7.47 0 7.47 Appl. & Cooking 0 21.1 0 21.13 Plug Loads 0 39.09 0 39.09 Outdoor Lighting 0 1.82 0 1.82 TOTAL COMPLIANCE 0 179.19 0 178.05 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 37.75 37.27 0.48 1.27 Net EUI2 37.75 37.27 0.48 1.27 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Ceiling has high level of insulation HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Verified heat pump rated heating capacity BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Grove Street Addition 2002 1 5 4 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Existing Lower Living Are Conditioned Ex HVAC System1 906 9 DHW Sys 1 Existing Unchanged Existing Upper Living Are Conditioned Ex HVAC System1 381 8 DHW Sys 1 Existing Unchanged 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status New Lower Living Area Conditioned New HVAC System2 373 9 DHW Sys 1 New New Upper Living Area Conditioned New HVAC System2 342 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing Condition Front Wall Existing Lower Living Are R-0 Wall 90 Front 351 69 90 none Existing No Left Wall Existing Lower Living Are R-0 Wall 180 Left 270 0 90 none Existing No Rear Wall Existing Lower Living Are R-0 Wall 270 Back 117 16 90 none Existing No Right Wall Existing Lower Living Are R-0 Wall 0 Right 297 32 90 none Existing No Front Wall 2 Existing Upper Living Are R-0 Wall 90 Front 232 22.1 90 none Existing No Left Wall 2 Existing Upper Living Are R-0 Wall 180 Left 112 9.4 90 none Existing No Rear Wall 2 Existing Upper Living Are R-0 Wall 270 Back 32 0 90 none Existing No Right Wall 2 Existing Upper Living Are R-0 Wall 0 Right 112 0 90 none Existing No Left Wall 3 New Lower Living Area R-15 Wall 180 Left 153 16 90 Extension New n/a Rear Wall 3 New Lower Living Area R-15 Wall 270 Back 234 52 90 Extension New n/a Right Wall 3 New Lower Living Area R-15 Wall 0 Right 117 0 90 Extension New n/a 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status Verified Existing Condition Left Wall 4 New Upper Living Area R-15 Wall 180 Left 120 16 90 Extension New n/a Rear Wall 4 New Upper Living Area R-15 Wall 270 Back 200 32 90 Extension New n/a Right Wall 4 New Upper Living Area R-15 Wall 0 Right 120 0 90 Extension New n/a Interior Surface New Lower Living Area>>Existing Lower Living Are R-0 Wall1 n/a n/a 261 0 n/a New n/a Interior Surface 2 New Upper Living Area>>Existing Upper Living Are R-0 Wall1 n/a n/a 200 0 n/a New n/a Roof Existing Lower Living Are R-11 Roof Attic n/a n/a 525 n/a n/a Existing No Roof 2 Existing Upper Living Are R-11 Roof Attic n/a n/a 381 n/a n/a Existing No Roof 3 New Lower Living Area R-38 Roof Attic n/a n/a 31 n/a n/a New n/a Roof 4 New Upper Living Area R-38 Roof Attic n/a n/a 342 n/a n/a New n/a Raised Floor Existing Lower Living Are R-0 Floor Crawlspace n/a n/a 906 n/a n/a Existing No Raised Floor 2 New Lower Living Area R-19 Floor Crawlspace n/a n/a 373 n/a n/a New n/a Interior Surface 3 Existing Upper Living Are R-0 Floor No Crawlspace n/a n/a 381 n/a n/a Existing No Interior Surface 4 New Upper Living Area R-0 Floor No Crawlspace n/a n/a 342 n/a n/a New n/a 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Existing Lower Living Are Attic RoofExisting Lower Living Are Ventilated 11 0.1 0.85 No No Existing No Attic Existing Upper Living Are Attic RoofExisting Upper Living Are Ventilated 9 0.1 0.85 No No Existing No Attic New Lower Living Area Attic RoofNew Lower Living Area Ventilated 2 0.1 0.85 Yes No New n/a Attic New Upper Living Area Attic RoofNew Upper Living Area Ventilated 2 0.1 0.85 Yes No New n/a FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientatio n Azimuth Width (ft) Heigh t (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition Window Window Front Wall Front 90 1 12 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 2 Window Front Wall Front 90 1 18 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 3 Window Front Wall Front 90 1 3 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 4 Window Front Wall Front 90 1 16 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 5 Window Rear Wall Back 270 1 16 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 6 Window Right Wall Right 0 1 6 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientatio n Azimuth Width (ft) Heigh t (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition Window 7 Window Right Wall Right 0 1 6 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 8 Window Front Wall 2 Front 90 1 5.8 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 9 Window Front Wall 2 Front 90 1 16.3 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 10 Window Left Wall 2 Left 180 1 4.7 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No Window 11 Window Left Wall 2 Left 180 1 4.7 1.19 Table 110.6-A 0.83 Table 110.6-B Bug Screen Existing No A Window Left Wall 3 Left 180 1 16 0.3 NFRC 0.5 NFRC Bug Screen New NA A 2 Window Rear Wall 3 Back 270 1 16 0.3 NFRC 0.5 NFRC Bug Screen New NA A 3 Window Rear Wall 3 Back 270 1 16 0.3 NFRC 0.5 NFRC Bug Screen New NA A 4 Window Left Wall 4 Left 180 1 16 0.3 NFRC 0.5 NFRC Bug Screen New NA A 5 Window Rear Wall 4 Back 270 1 16 0.3 NFRC 0.5 NFRC Bug Screen New NA A 6 Window Rear Wall 4 Back 270 1 16 0.3 NFRC 0.5 NFRC Bug Screen New NA OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2)U-factor Status Verified Existing Condition Door Front Wall 20 0.5 Existing No Door 2 Right Wall 20 0.5 Existing No 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2)U-factor Status Verified Existing Condition 2 Rear Wall 3 20 0.2 New n/a OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco R-0 Wall1 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Attic RoofExisting Lower Living Are Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofExisting Upper Living Are Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofNew Lower Living Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofNew Upper Living Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 R-0 Floor Crawlspace Floors Over Crawlspace Wood Framed Floor 2x12 @ 16 in. O. C.R-0 None / None 0.216 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x12 R-19 Floor Crawlspace Floors Over Crawlspace Wood Framed Floor 2x10 @ 16 in. O. C.R-19 None / None 0.046 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking Cavity / Frame: R-19 / 2x10 R-11 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-11 None / None 0.081 Over Ceiling Joists: R-1.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board R-0 Floor No Crawlspace Interior Floors Wood Framed Floor 2x12 @ 16 in. O. C.R-0 None / None 0.196 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x12 Ceiling Below Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Not Required Not Required N/A n/a n/a 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#)Status Verified Existing Condition Existing Water Heating System DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location Status Verified Existing Condition DHW Heater 1 Gas Small Storage 1 50 EF 0.53 Btu/Hr 75000 0 80 n/a Existing No WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Status Verified Existing Condition Existing HVAC System Ex HVAC System1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 n/a n/a Existing No 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Status Verified Existing Condition Existing HVAC System New HVAC System2 Heat pump heating cooling Heat Pump System 2 1 Heat Pump System 2 1 n/a n/a New No HVAC - HEATING UNIT TYPES 01 02 03 04 05 Name System Type Number of Units Heating Efficiency Heating Unit Brand Heating Component 1 Gas wall furnace 1 AFUE - 67.1 n/a HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 2 Multi-split HP-ductless 1 HSPF 8.8 24000 22800 EERSEER 15 12.2 Not Zonal Single Speed Heat Pump System 2-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 2-hers-htpump Not Required 0 Not Required Not Required No No Yes Yes 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street Addition Calculation Date/Time:2025-06-25T10:36:19-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Grove Street Addition (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-06-25   10:36:37 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Timothy Carstairs Carstairs Energy Inc.06/25/2025 2238 Bayview Heights Dr STE E CEA 2022 Los Osos, CA 93402 8059049048 CHRISTOPHER ALLEN CWA Studios 06/25/2025 1668 Sydney Street C35818 San Luis Obispo, CA 93401 8052865186 425-P010196042A-000-000-0000000-0000 06/25/2025 11:50 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. DESCRIPTION THIS PROJECT CONSISTS OF A 715 SF ADDITION TO AN EXISTING RESIDENCE. THIS ADDITION SHALL PROPOSE 4 ADDITIONAL BEDROOMS AND 1 BATHROOM TO THE EXISTING 3 BEDROOM 1 BATHROOM RESIDENCE. 1 (E) BEDROOM SHALL BE RECONFIGURED TO ACCOMMODATE THE ADDITION OF 1 BATHROOM AND CIRCULATION. THEREFORE, FINAL S.F.R. SHALL CONTAIN 5 BEDROOMS AND 2 BATHROOMS.SITE INFORMATION EXISTING BUILDING INFORMATION JURISDICTION ZONING APN STREET ADDRESS GROSS LOT SIZE BUILDING AREAS PROPOSED INFORMATION TWONUMBER OF STORIES R-1 (RESIDENTIAL)OCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE SPRINKLERED CLASS A ROOFINGROOF RATING TWO STORYNUMBER OF STORIES R (RESIDENTIAL) / UOCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSEDFIRE SPRINKLERS CITY OF SAN LUIS OBISPO LOW DENSITY RESIDENTIAL (R-1) 001-056-052 619 GROVE STREET, SAN LUIS OBISPO, CA 93401 0.08 ACRES (3,589 SF) CLASS AROOF RATING 25 FEET ALLOWEDMAXIMUM HEIGHT PROPERTY IS NOT LOCATED WITHIN A HIGH FIRE RISK AREA OR FLOOD PLAIN AREAHAZARDS LOT COVERAGE MAX 40% = 3,589 X 0.4 = 1,435.6 SF. PROPOSED = 1,275 SF. 1,275 / 3,589 = 35.5% 1 SPACE PROVIDED IN DRIVEWAY PER PREVIOUS LOT SPLITPARKING LEGAL DESCRIPTION CY SLO PM 84/92-93 PAR 2 1 SPACE PROVIDED IN DRIVEWAYPARKING NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSED T1.0 Title Sheet, General Notes + Project Data Sheet Index OWNER Project Directory SOILS ARCHITECT CWA STUDIOS 1668 SYDNEY STREET SAN LUIS OBISPO. CA 93401 CONTACT: CHRIS ALLEN, AIA. 805 286 5186 Drawing Log SET ISSUE DATE REVISION Project Notes ENERGY CARSTAIRS ENERGY CALCULATIONS 2238 BAYVIEW HEIGHTS DRIVE, SUITE E LOS OSOS, CA 93402 CONTACT: TIM CARSTAIRS. 805 904 9048 Project Data T1.1 INDEX, DATA + NOTES STRUCTURAL Calgreen Mandatory Measures 1.PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL SHALL MANAGE STORMWATER DURING CONSTRUCTION. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. CALGREEN 4.106.2.2 2.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED AND SHALL COMPLY WITH THE PLUMBING FIXTURE AND FITTINGS SCHEDULE ON THIS SHEET. CALGREEN 4.303.3.1 3.AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1 - CONTROLLERS SHALL BE WEATHER- OR SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANT WATERING NEEDS AS WEATHER OR SOIL CONDITIONS CHANGE. 2 - WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). CALGREEN 4.304.1 4.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE CLOSED WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY TO PREVENT PASSAGE OF RODENTS. CALGREEN 4.406.1. 5.RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 60% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4; OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. CALGREEN 4.408.1 6.DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION PER CALGREEN 4.504.1. 7.ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS PER CALGREEN 4.504.2.1. 8.PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.2.2. 9.AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS PER CALGREEN 4.504.2.3. 10.DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED PER CALGREEN 4.504.2.4. 11.CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.3. 12.EIGHTY (80) PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERINGINSTITUTE (RFCI) FLOORSCORE PROGRAM PER CALGREEN 4.504.4. 13.PARTICLEBOARD, MEDIUM FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR OR EXTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS PER CALGREEN 4.504.5. 14.VAPOR RETARDER AND CAPILLARY BREAK OF 4” THICK BASE OF ½” OR LARGER CLEAN AGGREGATE SHALL BE INSTALLED AT SLAB ON GRADE FOUNDATIONS PER CALGREEN 4.505.2. 15.MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING SHALL BE CHECKED BEFORE ENCLOSURE PER CALGREEN 4.505.3. 16.BATHROOM EXHAUST FANS SHALL BE DUCTED TO TERMINATE OUTSIDE AND BE PROVIDED IN EVERY BATHROOM PER CALGREEN 4.506.1. 17.WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED LOUVERS OR COVERS WHICH CLOSE WHEN THE FAN IS OFF. COVERS OR LOUVERS SHALL HAVE A MINIMUM INSULATION VALUE OF R-4.2 PER CALGREEN 4.507.1. 18.PER CALGREEN 4.507.2 DUCT SYSTEMS ARE SIZED, DESIGNED, AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS: 1. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ACCA (MANUAL J) OR EQUIVALENT. 2. SIZE DUCT SYSTEMS ACCORDING TO ACCA 26-D (MANUAL D) OR EQUIVALENT. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S (MANUAL S) OR EQUIVALENT. 19.OPERATION + MAINTENANCE MANUAL TO BE SUPPLIED AT FINAL INSPECTION. 20.MANAGE STORMWATER PER CALGREEN CODE REQUIREMENTS. 4106.2 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 25.0702 Deferred Submittals / Separate Permits 1.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDER-DRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. SURVEY MBS LAND SURVEYS 3559 SOUTH HIGUERA ST. SAN LUIS OBISPO CA 93401 CONTACT: MICHAEL B STANTON 805 594 1960 ARCHITECTURAL1.ALL WORK SHALL BE IN CONFORMANCE WITH THE 2022 EDITIONS OF THE CALIFORNIA BUILDING CODES 2.ANY/ALL DEFERRED SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT AND/OR PROJECT ENGINEER PRIOR TO SUBMISSION TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL. 3.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. THE CURRENT ADOPTED STANDARDS ARE DATED MAY 2023. 4.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. 5.THE PUBLIC IMPROVEMENTS SHALL BE SUBSTANTIALLY COMPLETE TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR PRIOR TO FINAL INSPECTION APPROVALS AND/OR OCCUPANCY OF ANY BUILDING. 6.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER AND SIDEWALK OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 7.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 805 781 7554 WITH AT LEAST A 48 HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. 8.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. 9.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. 10.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED DURING ALL CONSTRUCTION AND GROUND DISTURBING ACTIVITIES PER THE CITY OF SAN LUIS OBISPO 11.TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN PERMANENT IMPROVEMENTS, PLANTINGS AND FACILITIES ARE IN PLACE. TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION APPROVALS. 12.THE EXISTING SEWER LATERAL SHALL BE TELEVISED AND APPROVED FOR REUSE OR SHALL BE REPAIRED/REPLACED. THE INSPECTION SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE UTILITIES DEPARTMENT PRIOR TO ISSUANCE OF A BUILDING PERMIT. 13.ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE VERTICAL AND GREATER AND AREAS USED TO CONVEY CONCENTRATED DRAINAGE SHALL BE PREPARED AND MAINTAINED TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED NO LATER THAN 30 DAYS PRIOR TO A REQUEST FOR FINAL INSPECTION APPROVAL. 14.REMODELING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS A VIOLATION OF CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELERS AND PAINTERS ARE REQUIRED TO USE "LEAD-SAFE" WORK PRACTICES PURSUANT TO TITLE 17, CA CODE OF REGULATIONS SECTION 36050. 15.PRIOR TO ANY DEMOLITION OR GRADING THE CONTRACTOR SHALL PROTECT ANY TREES ADJACENT TO THE WORK ZONE. 16.THE MANDATORY PROVISIONS OF CALGREEN CHAPTER 4 SHALL BE APPLIED TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. CALGREEN 301.1.1 17.ON AND AFTER JANUARY 1, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. CALGREEN 301.1.1 18.APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER ORDINANCE OR LAW. CBC 105.4 19.THIS PROJECT IS LOCATED IN THE HIGH FIRE SEVERITY ZONE AS PER CITY OF SAN LUIS OBISPO California Building Code Chapter 7A Req. THE CITY OF SAN LUIS OBSIPO IS CONSIDERED A "COMMUNITY AT RISK" DUE TO THE THREAT OF WILDFIRE IMPACTING THE URBAN COMMUNITY. THE CITY SHALL CONTINUE TO ENHANCE THE FIRE SAFETY AND CONSTRUCTION CODES FOR NEW BUILDINGS IN ORDER TO REDUCE THE RISK OF URBAN FIRES THAT MAY RESULT FROM WILDFIRES. NEW BUILDINGS CITYWIDE SHALL INCORPORATE THE FOLLOWING CONSTRUCTION METHODS AND MATERIALS: IGNITION RESISTANT EXTERIOR WALL COVERINGS; FIRE SPRINKLER PROTECTION IN ATTIC AREAS (AT LEAST ONE "PILOT HEAD"); EMBER RESISTANT VENT SYSTEMS FOR ATTICS AND UNDER FLOOR AREAS, PROTECTED EAVES AS IDENTIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7A. CRC R337.1.2. STORK, WOLFE & ASSOCIATES 555 CHORRO ST. SUITE A1 SAN LUIS OBISPO, CA 93401 CONTACT: JUSTIN WOLFE, PE. PH: 805 548 8604 STRUCTURAL AS1.1 ARCHITECTURAL SITE A2.1 EXISTING FLOOR PLAN + ROOF PLAN T1.2 A3.1 EXISTING BUILDING ELEVATIONS MEP1 ELECTRICAL FLOOR PLAN + NOTES S0.1 STRUCTURAL GENERAL NOTES S2.1 FOUNDATION PLAN S1.2 TYPICAL DETAILS S2.3 S3.1 STRUCTURAL DETAILS ROOF FRAMING PLAN S0.2 STRUCTURAL GENERAL NOTES S1.1 TYPICAL DETAILS A4.1 PROPOSED BUILDING SECTIONS S1.3 TYPICAL DETAILS S2.2 SECOND FLOOR FRAMING PLAN S3.2 STRUCTURAL DETAILS CALGREEN MANDATORY MEASURES G r o v e S t r e e t R e s i d e n t i a l A d d i t i o n 6 1 9 G r o v e S t r e e t , S a n L u i s O b i s p o , C A 9 3 4 0 1 A5.1 ARCHITECTURAL DETAILS N/A T1.3 CALGREEN MANDATORY MEASURES Vicinity Map S3.3 STRUCTURAL DETAILS Construction Documents for C1.1 TOPOGRAPHIC MAP PROJECT LOCATION CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a s tu d i os BUILDING AREAS (EXISTING) (PROPOSED) PRIMARY RESIDENCE (EXISTING) 1,287 SQ. FT. PROPOSED ADDITION TO PRIMARY GROUND FLOOR 373 SQ. FT. SECOND FLOOR 342 SQ. FT. TOTAL (INCLUDING EXISTING RESIDENCE) 2,002 SQ. FT. N/ASOILS REPORT JOHN ROURKE 163 SERRANO HEIGHTS DRIVE SAN LUIS OBISPO. CA 93405 CONTACT: JOHN ROURKE. PH: 805 440 4973 A2.2 PROPOSED FLOOR PLAN + ROOF PLAN A3.2 PROPOSED BUILDING ELEVATIONS AS1.2 ARCHITECTURAL SITE DETAILS Standard Public Works Notes a.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. (THE CURRENT ADOPTED STANDARDS ARE DATED SEPTEMBER 2022. b.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY, WITHIN CITY EASEMENTS, OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. c.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK, OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. d.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST A 48-HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. e.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. f.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. g.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. h.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. Stormwater Compliance Summary THE PROJECT IS NOT A REGULATED PROJECT SUBJECT TO REGIONAL WATER QUALITY CONTROL BOARD RESOLUTION R3-2013-0032 “POST CONSTRUCTION STORMWATER MANAGEMENT REQUIREMENTS FOR DEVELOPMENT PROJECTS IN THE CENTRAL COAST REGION” BASED ON THE FOLLOWING: ☒PROJECT DOES NOT CREATE AND/OR REPLACE 2,500 SQUARE FEET OR MORE OF IMPERVIOUS AREA ☐PROJECT TYPE IS LISTED IN SECTION B.1.B (STATE WHICH): Applicable Governing Codes: 2022 2022 2022 CALIFORNIA BUILDING CODE, VOLUMES 1+2 CALIFORNIA ELECTRIC CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA GREEN BUILDING CODE CALIFORNIA FIRE CODE CALIFORNIA ENERGY CODE CALIFORNIA RESIDENTIAL CODE 2022 2022 2022 2022 2022 SAN LUIS OBISPO MUNICIPAL CODE NOT TO SCALE T1.4 ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS T1.0 CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a s tu d i os CalGreen Mandatory Measures T1.1 CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a s tu d i os T1.2 CalGreen Mandatory Measures T1.3 CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a s tu d i os Energy Compliance Forms T1.4 CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a s tu d i os Energy Compliance Forms C1.1 Topographic Map CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. COUNTY P/B DEPARTMENT kmcproject:applicant / owner:CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 05/08/25 25.0508 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a s tu d i osSLO CITY PERMIT No. BLDG-0000-0000CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A RCHITE C T S TATE OF C A L I F O R N IAResidential Addition619 Grove St.San Luis Obispo, CA 93401John SIG TEL GM PGE JOHN G. MOORE 11/92 35'M&CFR1&R2 35'M&CFR1&R2 GROVE STREETPARCEL 1 PARCEL 2 WILSON STREET 168420 Architectural Site Plan11/8" = 1'-0" NEW UNDER SIDEWALK DRAIN, ENSURING COMPLIANCE WITH CITY STANDARDS AND REGULATIONS. THIS SETUP ENSURES THAT STORMWATER IS EFFECTIVELY MANAGED, REDUCING THE RISK OF FLOODING AND MAINTAINING THE INTEGRITY OF THE PROPERTY AND SURROUNDING INFRASTRUCTURE. 3 AS1.2 11 22 9 3 6 8 1112 14 15 16 DIRECTION OFFIRE HYDRANT17 18 19 20 19 19 7 7 7 55 10 13 GROVE ST(PUBLIC STREET)4" SCHEDULE 40 PVC DRAIN PIPE 19 4 77 7 21 22 B AS1.1 23 20'-0"5'-0"5'-0"5'-0"17'-6 3/4" AS1.2 Architectural Site Details CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. COUNTY P/B DEPARTMENT kmcproject:applicant / owner:CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 05/08/25 25.0508 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a s tu d i osSLO CITY PERMIT No. BLDG-0000-0000CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IAResidential Addition619 Grove St.San Luis Obispo, CA 93401John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405Liberty Grinder Pump Specification Sidewalk Underdrain Per City Standards N.T.S. 8 3 N.T.S. A2.1 Existing Floor Plans + Roof Plan CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i o n s . c 202 5 c w a REQUIRED TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURES TO BE DEMOLISHED AND ADJACENT FACILITIES TO REMAIN. j.BEFORE COMMENCING WORK, THE CONTRACTOR SHALL VERIFY THE LOCATION AND SIZE OF ANY EXISTING UTILITIES SERVING THE PROJECT. ANY DISCREPANCY BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR DIRECTION BEFORE PROCEEDING WITH ANY WORK. k.COORDINATE ALL ITEMS REMOVED WITH OWNER TO DETERMINE WHICH ITEMS ARE TO BE REUSED, STORED OR DISCARDED. 22 22 ATTIC ACCESS FRONT PORTION OF RESIDENCE CONTAINS LIVING ROOM AND KITCHEN, TO REMAIN SLOPE SLOPE SLOPESLOPESLOPESLOPESLOPE SLOPE 4 3 3 4 4 1 A BB 20'-3 1/4"33'-8 1/8"13'-4 5/8"25'-6 1/2"3'-8 1/4"14'-6"15'-5 7/8"BB BB BB C DN E 42311E 42311 15'-6 3/4"15'-6 3/4"D Proposed Floor Plans, Roof Plan, and Schedules CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND OTHER SIMILAR CREATURES. VENTILATION REQUIREMENTS SHALL BE CALCULATED USING 1/300 OF ATTIC AREA PROVIDED A VAPOR RETARDER BE APPLIED TO THE WARM SIDE OF THE ATTIC INSULATION. NOT LESS THAN 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY. THE BALANCE OF THE REQUIRED VENTILATION PROVIDED SHALL BE LOCATED IN THE BOTTOM ONE-THIRD OF THE ATTIC SPACE. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. PER 2022 CRC R806.2.2. EXISTING ROOF TO REMAIN2"SEISMIC GAP1'-6" DN CLOSET C C 1'-6" 3 7/8" 3 7/8" 1/A4.12/A4.11/A4.12/A4.1DDD D D 2" SEISMIC GAP 2"SEISMIC GAP2" SEISMIC GAP A3.1 Existing Building Elevations CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t EXISTING. 1 A 1 A 1 A 1 A 3 B 3 B 3 B 3 B 4 - 4 - 4 -2/A4.1 A3.2 Proposed Building Elevations CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t VENT LOCATIONS 2.PROVIDE A MINIMUM OF 18" X 24" CLEAR CRAWL SPACE ACCESS. Under-Floor Ventilation Calc1/A4.14 - 4 - A4.1 Proposed Building Sections CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t 11 6 9 WHERE OCCURS FINISH GRADE WHERE OCCURS CONCRETE FOUNDATION FLOOR FRAMING PER STRUCTURAL BACKING ROD AND CONTINUOUS SEALANT BEAD Typical Weep @ Base of Exterior Wall RAISED FLOOR SYSTEMA IN A WEATHER BOARD FASHION OVER MANUFACTURED SHOWER PAN OR FIELD CONSTRUCTED SHOWER PAN. Shower Pan Waterproofing 3" = 1'-0"1 Aging-In-Place Design / Fall Prevention 8 9 CAD file: cwa job no: drawn by: plot date: 20240 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT KSproject:Residential Addition619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A R CHITE C T S TATE OF C A L I F O R N IA07/02/25 25.0702 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they w ere prepared and publication thereof is expressly limited to such use unless otherwise approved by the a r chi t ec t . Ti t le t o t hes e pl a ns an d spec ifi ca t ions remains w ith cw a studios w ithout prejudice. Visual contac t w i t h t hes e p lans a nd s pec ifi ca t ion s s hal l constitute prim a face evidence of the acceptance of t h e se r es t r ic t i Whole House Ventilation Calculation FLOOR AREA (SF)NBR OF BR QFAN (cfm) 2002 5 105SOSSOSH3S GFI WD J S0.1 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401 S0.2 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401 S1.1 Typical Details CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401 CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S1.2 Typical Details CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S1.3 Typical Details CAD file: SWA job no: drawn by: plot date: 25053 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S2.1 Foundation Plan CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S2.2 Second Floor Framing Plan CAD file: SWA job no: drawn by: plot date: 25053 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S2.3 Roof Framing Plan CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S3.1 Structural Details CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S3.2 Structural Details CAD file: SWA job no: drawn by: plot date: 25053 016 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 07.01.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original s i t e f o r w h i c h t h e y w e r e p r e p a r e d a n d publication thereof is expressly li mit ed to such use unless otherwise approved by the a r c h i t e c t . T i t l e t o t h e s e p l a n s a n d spe c i f ica t io ns r e m ai ns wi t h cwa s t ud io s without prejudice. Visual contact with these pl an s a nd spe c if i ca t ion s sh al l con sti t ute prima f ace evidence of the acceptance of these restrictions. c 2020 cwa studiosproject:applicant /owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 93401S3.3 Structural Details Calculations Job #: SWA 25053 Date: 6/29/25 Contents Load Tables 1 Roof & Floor Framing 2-7 Wall Stud / Post Design 8-18 Lateral Design 19-36 Foundation Design 37 Structural Calculations For RESIDENTAIL ADDITION 619 Grove St. San Luis Obispo, CA 93401 Client: CWA Studios Load Tables: Roof Framing Roof Ceiling Comp Shingles =6.00 psf 5/8" plywood sheathing =1.90 psf 2x8 @ 16" o.c. =2.00 psf Insulation =0.50 psf 0.50 psf 2x6 @ 16" o.c. =1.50 psf Gyp Ceiling =3.00 psf Subtotal =10.40 psf 5.00 psf Slope correction for 5:12 =1.01 1.00 n/a Subtotal =10.5 psf 5.0 psf misc (sprinklers, overframing etc.) =1.50 psf 2.00 psf Total Roof DL = 12.0 psf 7.0 psf Roof Lr =20.00 psf N/A Floor Framing Flooring =4.00 psf 3/4" Plywd.=2.30 psf 2−2x10 @ 16" o.c. =3.40 psf gyp ceiling / Plaster =3.00 psf Fire sprinklers =1.00 psf Misc.=3.30 psf Total Floor DL = 17.00 psf Floor LL =40.00 psf Exterior Walls Stucco / Stone Veneer =10.00 psf Plywood sheathing =1.50 psf 2x6 wood studs @ 16" o.c.=1.50 psf Insulation =0.50 psf 5/8" gypboard =3.00 psf Misc.=1.50 psf Total Exterior Wall DL = 18.00 psf 2x6 wood studs @ 16" o.c.=1.50 psf Insulation =0.50 psf 5/8" gypboard [two sides]=6.00 psf Misc.=2.00 psf Total Interior Wall DL = 10.00 psf Interior Walls PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 1 2 Multiple Simple Beam LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: ROOFDescription : BEAM Size :2x8, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf RR1 Applied Loads Unif Load: D = 0.0170, Lr = 0.020 k/ft, Trib= 1.330 ft Design Summary Max fb/Fb Ratio =0.787 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 7.375 inft 46.05 psi Fb : Allowable : 1,552.50 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.205 : 1 14.160 ft 1,222.12 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.374 in Transient Upward 0.000in Total Downward 0.691 in Total Upward 0.000 in 0.17 0.200.17 0.20 Ratio 473 256Ratio LC: Lr Only LC: +D+Lr LC:LC: 3 4 5 Multiple Simple Beam LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: FLOORDescription : BEAM Size :2x10, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf FJ1 Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft Design Summary Max fb/Fb Ratio =0.982 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 7.250 inft 53.48 psi Fb : Allowable : 1,138.50 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.297 : 1 13.775 ft 1,117.71 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.336 in Transient Upward 0.000in Total Downward 0.479 in Total Upward 0.000 in 0.16 0.390.16 0.39 Ratio 517 363Ratio LC: L Only LC: +D+L LC:LC: BEAM Size :2-2x10, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf FJ2 Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft Design Summary Max fb/Fb Ratio =0.636 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 8.250 inft 30.65 psi Fb : Allowable : 1,138.50 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.170 : 1 0.000 ft 723.66 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.282 in Transient Upward 0.000in Total Downward 0.401 in Total Upward 0.000 in 0.19 0.440.19 0.44 Ratio 702 493Ratio LC: L Only LC: +D+L LC:LC: 6 use 2-2x10 @ 16" o.c. Multiple Simple Beam LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: BEAM Size :3-1.75x9.25, Microllam LVL, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 iLevel Truss Joist MicroLam LVL 2.0 E 2,600.0 2,600.0 2,510.0 750.0 2,000.0 1,016.54 285.0 1,555.0 42.010 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf FB1 Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0190, Lr = 0.020 k/ft, Trib= 9.0 ft Unif Load: D = 0.0180 k/ft, Trib= 8.0 ft Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 8.0 ft Design Summary Max fb/Fb Ratio =0.644 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 5.250 inft 108.65 psi Fb : Allowable : 2,693.68 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 285.00 psi fb : Actual : Max fv/FvRatio =0.381 : 1 9.730 ft 1,734.37 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.127 in Transient Upward 0.000in Total Downward 0.334 in Total Upward 0.000 in 2.44 1.680.952.44 1.680.95 Ratio 991 377Ratio LC: L Only LC: +D+0.750Lr+0.750L LC:LC: BEAM Size :4x6, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2021, ASCE 7-16 Douglas Fir-Larch No.1 1000 1000 1500 625 1700 620 180 675 31.21 Eminbend - xx ksi Wood Species : Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf HDR1 Applied Loads Unif Load: D = 0.0190, Lr = 0.020 k/ft, Trib= 7.50 ft Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 7.50 ft Unif Load: D = 0.0180 k/ft, Trib= 8.0 ft Design Summary Max fb/Fb Ratio =0.421 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 1.500 inft 58.42 psi Fb : Allowable : 1,296.01 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.325 : 1 2.550 ft 546.25 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.007 in Transient Upward 0.000in Total Downward 0.017 in Total Upward 0.000 in 0.62 0.450.23 0.62 0.450.23 Ratio 5402 2156Ratio LC: L Only LC: +D+0.750Lr+0.750L LC:LC: 7 Wind Criteria ASCE 7−16 − Chapter 30 ASCE 7−16 Design Wind Loads [Component & Cladding]  Wind Design Force: P=qh (GCp -GCpi)(30.3−1) qh = 0.00256KzKztKdKeV2 26.10−1 Kz =0.66 (Exp. B) Sect 26.10.1 and Table 26.10−1 Kzt =1.00 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.00 mph Fig. 26.5−1B qz =12.4 psf (lrfd) At =10.0 ft2 min. GCp =1.0 (Zone 4 &5) Fig.30.3−1 GCp =−1.1 (Zone 4) Fig.30.3−1 GCp =−1.4 (Zone 5)Fig.30.3−1 GCpi =0.18 26.13 & Table 26.13−1 P= −15.90 psf (Zone 4) P= −19.63 psf (Zone 5) PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 8 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C1 (2nd Floor Stud @ Gridline 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 2x4Analysis Method 10.5Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb + 900.0 900.0 psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Fact 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi Yes Minimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 10.5 ft, Fully braced against buckling ABOUT Y-Y Axis Brace condition for deflection (buckling) along columns : Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 11.948 lbs * Dead Load Factor AXIAL LOADS . . . Roof + Ceiling + FLoor + Wall Self wt.: Axial Load at 10.50 ft, D = 0.4410, Lr = 0.20 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.3796 Location of max.above base 5.215 ft Applied Axial 0.4529k Applied Mx 0.09646 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 10.50 psi 180.0Allowable Shear psi 0.05833 : 1 Bending Compression Tension Location of max.above base 0.0 ft : 1 At maximum location values are . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.03675 k Bottom along Y-Y 0.03675 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.2257 in at 5.285 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 347.790 psi Other Factors used to calculate allowable stresses . . . for load combination : n/a Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results D Only 0.900 PASS PASS0.0 0.0 10.50 ft0.247 ft0.2499 +D+L 1.000 PASS PASS5.215 0.05833 0.0 ft0.224 ft0.3796 +D+Lr 1.250 PASS PASS0.0 0.0 10.50 ft0.182 ft0.3531 +D+0.750Lr+0.750L 1.250 PASS PASS0.0 0.0350 0.0 ft0.182 ft0.3260 +D+0.750L 1.150 PASS PASS5.215 0.03804 0.0 ft0.196 ft0.2679 +0.60D 1.600 PASS PASS0.0 0.0 10.50 ft0.143 ft0.1454 9 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C1 (2nd Floor Stud @ Gridline 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 0.453 +D+L 0.037 0.4530.037 +D+Lr 0.653 +D+0.750Lr+0.750L 0.028 0.6030.028 +D+0.750L 0.028 0.4530.028 +0.60D 0.272 Lr Only 0.200 L Only 0.0370.037 Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftft inin 0.000 +D+L 0.0000 0.226 5.285ftft inin 0.000 +D+Lr 0.0000 0.000 0.000ftft inin 0.000 +D+0.750Lr+0.750L 0.0000 0.169 5.285ftft inin 0.000 +D+0.750L 0.0000 0.169 5.285ftft inin 0.000 +0.60D 0.0000 0.000 0.000ftft inin 0.000 Lr Only 0.0000 0.000 0.000ftft inin 0.000 L Only 0.0000 0.226 5.285ftft inin 0.000 Sketches 10 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C2 (First Floor Stud @ Gridline 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 2x4Analysis Method 9Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb + 900.0 900.0 psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Fact 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi Yes Minimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 9 ft, K = Fully braced against buckling ABOUT Y-Y Axis Brace condition for deflection (buckling) along columns : Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 10.241 lbs * Dead Load Factor AXIAL LOADS . . . Roof + Ceiling + FLoor + Wall Self wt.: Axial Load at 9.0 ft, D = 0.850, Lr = 0.20, L = 0.40 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.6140 Location of max.above base 4.470 ft Applied Axial 1.260k Applied Mx 0.07087 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 9.0 psi 180.0Allowable Shear psi 0.050 : 1 Bending Compression Tension Location of max.above base 9.0 ft : 1 At maximum location values are . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.03150 k Bottom along Y-Y 0.03150 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.1218 in at 4.530 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 461.640 psi Other Factors used to calculate allowable stresses . . . for load combination : n/a Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results D Only 0.900 PASS PASS0.0 0.0 9.0 ft0.327 ft0.3590 +D+L 1.000 PASS PASS4.470 0.050 9.0 ft0.297 ft0.6140 +D+Lr 1.250 PASS PASS0.0 0.0 9.0 ft0.242 ft0.4291 +D+0.750Lr+0.750L 1.250 PASS PASS0.06040 0.030 0.0 ft0.242 ft0.5303 +D+0.750L 1.150 PASS PASS0.0 0.03261 0.0 ft0.262 ft0.4727 +0.60D 1.600 PASS PASS0.0 0.0 9.0 ft0.192 ft0.2057 11 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C2 (First Floor Stud @ Gridline 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 0.860 +D+L 0.032 1.2600.032 +D+Lr 1.060 +D+0.750Lr+0.750L 0.024 1.3100.024 +D+0.750L 0.024 1.1600.024 +0.60D 0.516 Lr Only 0.200 L Only 0.032 0.4000.032 Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftft inin 0.000 +D+L 0.0000 0.122 4.530ftft inin 0.000 +D+Lr 0.0000 0.000 0.000ftft inin 0.000 +D+0.750Lr+0.750L 0.0000 0.091 4.530ftft inin 0.000 +D+0.750L 0.0000 0.091 4.530ftft inin 0.000 +0.60D 0.0000 0.000 0.000ftft inin 0.000 Lr Only 0.0000 0.000 0.000ftft inin 0.000 L Only 0.0000 0.122 4.530ftft inin 0.000 Sketches 12 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C3 (First Floor Stud @ Gridline 15Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 2x6Analysis Method 9Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb + 900.0 900.0 psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 1.50 in Exact Depth 5.50 in Area 8.250 in^2 Ix 20.797 in^4 Iy 1.547 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Fact 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi Yes Minimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 9 ft, K = Fully braced against buckling ABOUT Y-Y Axis Brace condition for deflection (buckling) along columns : Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 16.093 lbs * Dead Load Factor AXIAL LOADS . . . Roof + Ceiling + FLoor + Wall Self wt.: Axial Load at 9.0 ft, D = 0.8140, Lr = 0.20, L = 0.40 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, W = 0.0270 k/ft DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.1607 Location of max.above base 0.0 ft Applied Axial 1.230k Applied Mx 0.0 k-ft Load Combination +D+L Load Combination +D+0.60W Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 13.255 psi 288.0Allowable Shear psi 0.04602 : 1 Bending Compression Tension Location of max.above base 9.0 ft : 1 At maximum location values are . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.1215 k Bottom along Y-Y 0.1215 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp Only, fc/Fc' Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.1211 in at 4.530 ft above base for load combination : W Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 927.65 psi Other Factors used to calculate allowable stresses . . . for load combination : n/a Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results D Only 0.900 PASS PASS0.0 0.0 9.0 ft0.663 ft0.1135 +D+L 1.000 PASS PASS0.0 0.0 9.0 ft0.625 ft0.1607 +D+Lr 1.250 PASS PASS0.0 0.0 9.0 ft0.540 ft0.1247 +D+0.750Lr+0.750L 1.250 PASS PASS0.0 0.0 9.0 ft0.540 ft0.1549 +D+0.750L 1.150 PASS PASS0.0 0.0 9.0 ft0.572 ft0.1403 +D+0.60W 1.600 PASS PASS4.470 0.04602 9.0 ft0.448 ft0.1211 +D+0.750Lr+0.750L+0.450W 1.600 PASS PASS0.06040 0.03452 9.0 ft0.448 ft0.1458 +D+0.750L+0.450W 1.600 PASS PASS0.06040 0.03452 9.0 ft0.448 ft0.1288 +0.60D+0.60W 1.600 PASS PASS4.470 0.04602 9.0 ft0.448 ft0.1115 13 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C3 (First Floor Stud @ Gridline 15Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +0.60D 1.600 PASS PASS0.0 0.0 9.0 ft0.448 ft0.05674 k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 0.830 +D+L 1.230 +D+Lr 1.030 +D+0.750Lr+0.750L 1.280 +D+0.750L 1.130 +D+0.60W 0.073 0.8300.073 +D+0.750Lr+0.750L+0.450W 0.055 1.2800.055 +D+0.750L+0.450W 0.055 1.1300.055 +0.60D+0.60W 0.073 0.4980.073 +0.60D 0.498 Lr Only 0.200 L Only 0.400 W Only 0.1220.122 Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftft inin 0.000 +D+L 0.0000 0.000 0.000ftft inin 0.000 +D+Lr 0.0000 0.000 0.000ftft inin 0.000 +D+0.750Lr+0.750L 0.0000 0.000 0.000ftft inin 0.000 +D+0.750L 0.0000 0.000 0.000ftft inin 0.000 +D+0.60W 0.0000 0.073 4.530ftft inin 0.000 +D+0.750Lr+0.750L+0.450W 0.0000 0.054 4.530ftft inin 0.000 +D+0.750L+0.450W 0.0000 0.054 4.530ftft inin 0.000 +0.60D+0.60W 0.0000 0.073 4.530ftft inin 0.000 +0.60D 0.0000 0.000 0.000ftft inin 0.000 Lr Only 0.0000 0.000 0.000ftft inin 0.000 L Only 0.0000 0.000 0.000ftft inin 0.000 W Only 0.0000 0.121 4.530ftft inin 0.000 14 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C3 (First Floor Stud @ Gridline 15Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 15 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C4 (Supporting FB1@ Gridline 15Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Wood Section Name 6x6Analysis Method 9Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.1 Fb + 1,200.0 1,200.0 psi 1,000.0 625.0 170.0 825.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf : Built-up columns 1.0 NDS 15.3.2 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Fact 1.0 Cf or Cv for Compression 1.0 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi No Minimum Basic Y-Y (depth) axis : X-X (width) axis : Unbraced Length for buckling ABOUT X-X Axis = 9 ft, K = Unbraced Length for buckling ABOUT Y-Y Axis = 9 ft, K = Brace condition for deflection (buckling) along columns : Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 59.006 lbs * Dead Load Factor AXIAL LOADS . . . Roof + Ceiling + FLoor + Wall Self wt.: Axial Load at 9.0 ft, D = 2.442, Lr = 0.9450, L = 1.680 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, W = 0.0270 k/ft DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.1821 Location of max.above base 0.0 ft Applied Axial 4.181k Applied Mx 0.0 k-ft Load Combination +D+L Load Combination +D+0.60W Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 3.615 psi 272.0Allowable Shear psi 0.01329 : 1 Bending Compression Tension Location of max.above base 0.0 ft : 1 At maximum location values are . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.1215 k Bottom along Y-Y 0.1215 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp Only, fc/Fc' Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.03302 in at 4.530 ft above base for load combination : W Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 758.85 psi Other Factors used to calculate allowable stresses . . . for load combination : n/a Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results D Only 0.900 PASS PASS0.0 0.0 9.0 ft0.788 ft0.1166 +D+L 1.000 PASS PASS0.0 0.0 9.0 ft0.759 ft0.1821 +D+Lr 1.250 PASS PASS0.0 0.0 9.0 ft0.687 ft0.1326 +D+0.750Lr+0.750L 1.250 PASS PASS0.0 0.0 9.0 ft0.687 ft0.1720 +D+0.750L 1.150 PASS PASS0.0 0.0 9.0 ft0.715 ft0.1511 +D+0.60W 1.600 PASS PASS4.470 0.01329 0.0 ft0.596 ft0.08665 +D+0.750Lr+0.750L+0.450W 1.600 PASS PASS4.470 0.009967 9.0 ft0.596 ft0.1548 +D+0.750L+0.450W 1.600 PASS PASS4.470 0.009967 9.0 ft0.596 ft0.1303 +0.60D+0.60W 1.600 PASS PASS4.470 0.01329 0.0 ft0.596 ft0.05199 16 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C4 (Supporting FB1@ Gridline 15Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCDCLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus Load Combination Results +0.60D 1.600 PASS PASS0.0 0.0 9.0 ft0.596 ft0.05198 k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis Reaction Axial Reaction @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My - End Moments Mx - End Moments D Only 2.501 +D+L 4.181 +D+Lr 3.446 +D+0.750Lr+0.750L 4.470 +D+0.750L 3.761 +D+0.60W 0.073 2.5010.073 +D+0.750Lr+0.750L+0.450W 0.055 4.4700.055 +D+0.750L+0.450W 0.055 3.7610.055 +0.60D+0.60W 0.073 1.5010.073 +0.60D 1.501 Lr Only 0.945 L Only 1.680 W Only 0.1220.122 Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftft inin 0.000 +D+L 0.0000 0.000 0.000ftft inin 0.000 +D+Lr 0.0000 0.000 0.000ftft inin 0.000 +D+0.750Lr+0.750L 0.0000 0.000 0.000ftft inin 0.000 +D+0.750L 0.0000 0.000 0.000ftft inin 0.000 +D+0.60W 0.0000 0.020 4.530ftft inin 0.000 +D+0.750Lr+0.750L+0.450W 0.0000 0.015 4.530ftft inin 0.000 +D+0.750L+0.450W 0.0000 0.015 4.530ftft inin 0.000 +0.60D+0.60W 0.0000 0.020 4.530ftft inin 0.000 +0.60D 0.0000 0.000 0.000ftft inin 0.000 Lr Only 0.0000 0.000 0.000ftft inin 0.000 L Only 0.0000 0.000 0.000ftft inin 0.000 W Only 0.0000 0.033 4.530ftft inin 0.000 17 Wood Column LIC# : KW-06016119, Build:20.23.2.14 STORK, WOLFE & ASSOCIATES (c) ENERCALC INC 1983-2022 DESCRIPTION:C4 (Supporting FB1@ Gridline 15Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 18 19 20 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 E−W L/B =0.67 Cp =0.8 (Windward) Fig.27.3−1 Cp =0.0 N/A (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =0.0 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =1.26 Cp =−1.30 (Windward)Fig.27.3−1 Cp =0.00 (Leeward)Fig.27.3−1 qGCp -qiGCi =−15.96 (Windward) qGCp -qiGCi =0.00 Mono slope (Leeward) qh GCp(x component) =−2.50 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 25.5 15 383 4,086 25.5 15 383 0 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 25.5 3 76.5 −191 25.5 3 76.5 0 Ptotal =3,895 lbs (lrfd) =2,337 lbs (asd) < Seismic = 4,227 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 21 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 N−S L/B =1.50 Cp =0.8 (Windward)Fig.27.3−1 Cp =−0.4 (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =−6.5 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =0.84 Cp =0.00 N/A (Windward)Fig.27.3−1 Cp =0.00 N/A (Leeward)Fig.27.3−1 qGCp -qiGCi =0.00 (Windward) qGCp -qiGCi =0.00 (Leeward) qh GCp(x component) =0.00 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 25.5 15 383 4,086 25.5 15 383 −2,471 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 25.5 3 76.5 0 25.5 3 76.5 0 Ptotal =6,557 lbs (lrfd) =3,934 lbs (asd) < Seismic = 4,227 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 22 { "request": { "date": "2025-06-29T16:10:08.835Z", "referenceDocument": "ASCE7-16", "status": "success", "url": "http://earthquake.usgs.gov/ws/designmaps/asce7-16.json? latitude=35.29054&longitude=-120.6566&riskCategory=II&siteClass=D&title=Example", "parameters": { "latitude": 35.29054, "longitude": -120.6566, "riskCategory": "II", "siteClass": "D", "title": "Example" } }, "response": { "data": { "pgauh": 0.476, "pgad": 0.841, "pga": 0.476, "fpga": 1.124, "pgam": 0.535, "ssrt": 1.074, "crs": 0.899, "ssuh": 1.195, "ssd": 2.045, "ss": 1.074, "fa": 1.07, "sms": 1.15, "sds": 0.766, "sdcs": "D", "s1rt": 0.396, "cr1": 0.901, "s1uh": 0.439, "s1d": 0.722, "s1": 0.396, "ts": 0.656, "t0": 0.131, "fv": null, "fv_note": "See Section 11.4.8", "sm1": null, "sd1": null, "sdc1": null, "sdc": null, "tl": 8, "t-sub-l": 8, "cv": 1.315, "twoPeriodDesignSpectrum": null, "twoPeriodMCErSpectrum": null, "verticalDesignSpectrum": null, "verticalMCErSpectrum": null }, "metadata": { "modelVersion": "v4.0.x", "pgadFloor": 0.5, "pgadPercentileFactor": 1, "s1MaxDirFactor": 1, "s1dFloor": 0.6, "s1dPercentileFactor": 1, "spatialInterpolationMethod": "linearloglinear", "ssMaxDirFactor": 1, "ssdFloor": 1.5, Pretty-print 6/29/25, 9:10 AM earthquake.usgs.gov/ws/designmaps/asce7-16.json?latitude=35.29054&longitude=-120.6566&riskCategory=II&siteClass=D&title=… https://earthquake.usgs.gov/ws/designmaps/asce7-16.json?latitude=35.29054&longitude=-120.6566&riskCategory=II&siteClass=D&title=Example 1/2 23 2022 CBC Seismic Criteria (based on the requirements of ASCE 7−16) 2022 CBC Section 1613 Earthquake Loads  Site Parameters: Site Class:DDefault Latitude =35.291 deg N Google Earth Longitude =120.657 deg W Google Earth Seismic Design Category:D USGS Design Maps SS =1.074 g USGS Design Maps Fa =1.20 Section 11.4.4 SMS =Fa SS =1.289 g (16−20) SDS =2/3 x SMS =0.859 g (16−22) SDS,MAX =2/3 x SMS,MAX =N/A g Calcs Pg. , Based on Section 12.8.1.3 S1 =0.396 g USGS Design Maps Fv =1.904 Table 1613.2.3(2) SM1 =Fv S1 =0.754 g (16−21) SD1 =2/3 x SM1 =0.503 g (16−23) ASCE 7−16 Section 12.8 Equivalent Lateral Force Procedure  Structural Parameters: hn =22.0 ft Ct =0.020 Table 12.8−2 x =0.75 " Ta =Ct(hn)x =0.20 sec (12.8−7) TL =8 sec > Ta Figure 22−14 R =6.50 Table 12.2−1 Ie =1.00 Table 1.5−2  Seismic Coefficient: Cs =SDS / (R/Ie)(12.8−2) =0.13 Cs,max =SD1 / [T x (R/Ie)]for T < TL (12.8−3) =0.38 Cs,min =0.044SDSIe > 0.01 (12.8−5) 0.04 Cs,min =0.5S1 / (R/Ie)for S1 > 0.6g (12.8−6) =0.03 light framed construction with plywd shear panels PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 24 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES  Seismic Base Shear: V =Cs W (12.8−1) =0.13 W =0.17 W =0.09 W =0.120 W Strength Level with Rho = 1.3 ASD Level ASD Level with Rho = 1.3 Strength Level ASCE 7−16 Section 12.8 25 Seismic Weights − 2−Story Portion (52X−74X) Second Floor Framing Height 10 ft +/− Roof Level Framing Height 20 ft +/− Roof Level Roof. . . w =19 psf A =401 sf W =7,641 lb Exterior Walls. . . w =18 psf L =51 ft htrib =4.0 ft W =3,672 lb Interior Walls. . . w =10 psf L =25 ft htrib =6.0 ft W =1,500 lb Total Sesimic Weight at Roof 12,813 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 26 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES Floor Level Typical Floor . . . w =17 psf A =403 sf W =6,851 lb Exterior Walls. . . walls above = 3672 lb w =18 psf L =51 ft htrib =10.0 ft W =12,852 lb Interior Walls. . . walls above = 1500 lb w =10 psf L =25.0 ft htrib =4.5 ft W =2,625 lb Total Sesimic Weight at Floor 22,328 lb Vertical Distribution Two Story Portion ~ ASD Level, Rho = 1.3 Level Seismic W V Height VxH % V Per SF Roof 12,813 1541 18 27742.9 53.4 2259 5.6 2nd floor 22,328 2686 9 24172.1 46.6 1968 4.9 4227 51915 4227 Total Base Shear V =4645 lb V =4227 lb LRFD ASD Level with Rho = 1.3 27 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES E−W Line Loads Roof Floor Line 0X. . .Line 0X. . . A trib. =186 ft2 A trib. =196 ft2 V dia. =1,045 lb V dia. =958 lb V in plane SW =309 lb V in plane SW =292 lb V roof =1,354 lb V total =1,354 lb V total =2,604 lb Line 22X. . .Line 22X. . . A trib. =216 ft2 A trib. =207 ft2 V dia. =1,214 lb V dia. =1,010 lb V in plane SW =185 lb V in plane SW =175 lb V roof =1,399 lb V total =1,399 lb V total =2,584 lb A total =401 ft2 A total =403 ft2 N−S Line Loads Roof Floor Line 0Y. . .Line 0Y. . . A trib. =204 ft2 A trib. =179 ft2 V dia. =1,146 lb V dia. =876 lb V in plane SW =433 lb V in plane SW =487 lb V roof =1,579 lb V total =1,579 lb V total =2,943 lb Line 15Y. . .Line 15Y. . . A trib. =198 ft2 A trib. =224 ft2 V dia. =1,113 lb V dia. =1,092 lb V in plane SW =381 lb V in plane SW =429 lb V roof =1,494 lb V total =1,494 lb V total =3,014 lb A total =401 ft2 A total =403 ft2 28 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)dl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0X 1,354 S 10.50 10.0 129 1 14.50 13,535 193 9,721 272 MST60 22X 1,399 S 9.00 10.0 155 1 9.00 13,990 193 3,745 1,205 MST60 0X 2,604 S 10.50 9.0 248 1 14.50 23,436 173 8,744 1,322 HDU2 22X 2,584 S 9.00 9.0 287 1 9.00 23,260 173 3,369 2,340 HDU2 Project: ______________________________________________________ V (lbs) E−W 2nd FLOOR E−W 1st FLOOR 29 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)dl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0Y 1,579 S 13.50 10.5 117 1 13.50 16,583 253 11,073 424 MST60 15Y 1,494 S 13.00 8.0 115 1 21.00 11,949 277 29,332 N/A MST60 0Y 2,943 S 15.50 9.0 190 1 15.50 26,484 281 16,193 1,110 HDU2 15Y 3,014 S 21.25 9.0 142 1 11.00 14,043 36 1,049 1,238 HDU2 S 9.0 142 1 10.25 13,086 259 6,517 674 HDU2 Project: ______________________________________________________ V (lbs) N−S 2nd FLOOR N−S 1st FLOOR 30 SHEAR WALL SCHEDULE ALLOWABLE VALUESShear WallSubfloor Connection (2 story or more)Concrete ConnectionPlywood 1/Nailing (10d's)VallSill Size FastenerVallSill Size FastenerVallSDS @ 8" o.c. 456 SW1one side 6" o.c. 339 SW1 2x 16d's @ 6" o.c. 374 SW1 2x 5/8" AB @ 4'-0" o.c. 372 SW1one side 4" o.c. 510 SW2 3x SDS @ 6" o.c.608 SW23x 5/8" AB @ 2'-8" o.c. 707 SW2one side 3" o.c.664 SW33x SDS @ 4" o.c. 912 SW3 3x 5/8" AB @ 2'-8" o.c. 707 SW3one side 2" o.c.869 SW43x SDS @3" o.c. 1216 SW4 3x 5/8" AB @ 1'-4" o.c. 1415 SW4Top Pl. Shear Clip ConnectionVallA35 @ 24" o.c.325 SW1A35 @ 12" o.c. 650 SW2A35 @ 8" o.c. 975 SW3A35 @ 6" o.c. 1300 SW4Shear Wall CapacityNOTES:Vall6" o.c.325SW11. Shear wall allowables based on NDS Table 4.3A4" o.c.510SW23" o.c.664SW32. Subfloor nailed connection allowables based on NDS Table 11N2" o.c.869SW4 2x sill, 16d's - Z = 1.6x118=188# ea.3. Subfloor SDS connection is Simpson SDS 1/4" dia.x 6" screws w/allowables per SimpsonSDS 1/4"x6"=190# x 1.6 = 304# ea.Holdowns4. Subfloor lag screw allowables based on NDS Table 11.5 for 3x sillMin. 1/2" dia x 8" = 1.6x390=620# ea.Type Uplift Cap. ChordHDU2 3075 2-2x5. Concrete connection allowables based on NDS Table 11EHDU4 4565 2-2x 2x sill, 5/8" dia. Bolts - Z = 1.6x930=1488# ea.HDU5 5175 2-2x 3x sill, 5/8" dia. Bolts - Z = 1.6x1180=1888# ea.HDU8 6970 4x 3x sill, 3/4" dia. Bolts - Z = 1.66x1540=2464# ea.HDU11 9535 6xHDU14 14925 6x 6. Top Pl. shear clip connection is Simpson A35 w/allowables per SimpsonHDQ8 7630 4x A35=650# ea.HHDQ11 11810 6xHHDQ14 13710 6x7. Holdown allowables per Simpson current catalog31 E-W Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 15.0 1.47 ok VDIA. - LINE 22X =1,214 lbs vdia. = 1,214 lbs /15.0 ft = 80.9 plf →285.7 plf D/C =0.3 Case 1 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 15.0 1.47 ok VDIA. - LINE 22X =1,010 lb vdia. = 1,010 lbs /15.0 ft = 67.3 plf →285.7 plf D/C =0.2 Case 1 (NDS Table 4.2C) N-S Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 15 22.0 0.68 ok VDIA. - LINE 15Y =1,113 lbs vdia. = 1,113 lbs /22.0 ft = 50.6 plf →214.3 plf D/C =0.2 Case 3 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 15 22.0 0.68 ok VDIA. - LINE 15Y =1,092 lb vdia. = 1,092 lbs /22.0 ft = 49.6 plf →214.3 plf D/C =0.2 Case 3 (NDS Table 4.2C) 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 32 Dia. chord design: line Vdia.(ASD)q = Vdia./L L D chord force Connector Connection Cap. D/C lb plf ft ft lbs MIN.lbs 0Y/15Y Roof 2,259 103 22 15 414 12−16d 2,447 0.17 0Y/15Y Floor 1,968 89 22 15 361 12−16d 2,447 0.15 Chord Force =qL2/D top pl. splice 12−16d 2,447 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 33 Collector Analysis (ASCE 12.10.2) Roof… Line 0X 1.25V = 1,306 lbs Ltotal =25.5 ft Lshearwall =13.5 ft v1 = V / L total =51.23 plf v2 = V / Lshearwall =96.76 plf v1 -v2 =-45.53 plf SW Distance Length (ft) 13.5 12.0 unit shear (plf -45.53 51.23 Drag load(lbs)0 -615 0 Max. Drag Load =615 lb (See above) 12 - 16d 2447 lb (calc. pg. )D/C =0.25 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 34 Floor… Line 0X 1.25V = 2,890 lbs Ltotal =25.5 ft Lshearwall =15.5 ft v1 = V / L total =113.32 plf v2 = V / Lshearwall =186.42 plf v1 -v2 =-73.11 plf SW Distance Length (ft) 15.5 10.0 unit shear (plf -73.11 113.32 Drag load(lbs)0 -1133 0 Max. Drag Load =1133 lb (See above) 12 - 16d 2447 lb (calc. pg. ) D/C =0.46 35 Nail Connection Structural Element: Nail : Species: Adjustment Factors: CM =1.00 C =1.00 CD =1.60 Ct =1.00 Ceg =1.00 Cg =0.98 Cdi =1.00 Ctn =1.00 Z =131 lb (10 dia. min. pentration reduction included) m(1-m 2n)1+REA 1-m n =12 nails D =0.162 in s =1.5 in Es =1,600,000 psi Em =1,600,000 psi NDS Table 4A As =8.25 in2 Am =8.25 in2 EsAs EmAm EmAm EsAs  = (180,000)(D 1.5)=11,737 lb/in u =1+s/2 x (1/EmAm+1/EsAs)=1.00 m =u-(u2-1)1/2 =0.95 =0.98 Shear Plate Adjusted Design Value: Z’ =Z x CDCMCtCgCCegCdiCtn NDS Table 10.3.1 = 204 lb/ea. Z’ (12−16d) =2,447 lb NDS (10.3−1)n[(1+REAmn)(1+m)-1+m2n] REA =lessor of or =1.0 x Top plates splice 12 − 16d DF No. 2 Cg = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 36 Foundation Design Allowable soil bearing pressure =1500 psf (CBC Table 1806.2) Footing Width W =16 in Footing Depth D=18 in Gridline 0Y /15Y (D+0.75Lr+0.75L) Roof DL =171 plf 171 plf Roof Lr =180 plf 135 plf 2 Floor DL =255 plf 255 plf 2 Floor LL =600 plf 450 plf 21 ft ht. 2x wall =378 plf 378 plf Ptotal =1,584 plf 1,389 plf Soil bearing = 1042 psf (Ptotal / W) <1500 psf FB1 (@ Grid 15Y)(D+0.75Lr+0.75L) Roof + Floor + Wall DL =2,442 lbs 2442 lbs Roof LL=945 lbs 709 lbs Floor LL =1,680 lbs 1260 lbs Ptotal =5,067 lbs 4,411 lbs Soil bearing = 1103 psf [Ptotal / (Wx2D)] <1500 psf PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 37 Construction and Demolition Recycling and Waste Plan Please read this form carefully. The goal is to clearly document and create a plan to recycle a minimum of 65% of construction and demolition materials for permits after January 1, 2017, per Title 24 Chapter 11 of the Green Building Code. This form must be filled out in its entirety. For questions, email RecycleRight@slocity.org or call (805) 781-7215. Step 1: Complete Recycling Form Project Type * Residential Commercial Project Category * Demolition New Construction Addition Remodel/Tenant Improvement Project Site Address * 619 Grove Street, San Luis Obispo, CA 93401 Project Description * THIS PROJECT CONSISTS OF A 715 SF ADDITION TO AN EXISTING RESIDENCE. THIS ADDITION SHALL PROPOSE 4 ADDITIONAL BEDROOMS AND 1 BATHROOM TO THE EXISTING 3 BEDROOM 1 BATHROOM RESIDENCE. 1 (E) BEDROOM SHALL BE RECONFIGURED TO ACCOMMODATE THE ADDITION OF 1 BATHROOM AND CIRCULATION. THEREFORE, FINAL SF SHALL CONTAIN 5 BEDROOMS AND 2 BATHROOMS. Estimated Project Cost * 95000 New Conditioned Square Footage * 715 Estimated Fine for Failure to Comply * 1900 Project Contact Name * Chris Allen Contact Phone Number * 8052865186 Contact Email Address * Type of Material to be Generated (check all that apply)* Mixed C&D Concrete/Asphalt Dirt Cardboard Metals Wood Other Once all Materials are checked, please enter weight estimates for each of these categories below. Estimated Quantity of Generated Materials (in tons) Concrete/Asphalt Estimate * .125 Dirt Estimate * .25 Cardboard Estimate * .125 Wood Estimate * .75 Note: a tonnage estimate guide can be found on the City 's Construction and Demolition webpage. If you plan to reuse or donate materials, please explain here. How will you transport the materials?* Self-Haul Roll-Off Company Which IWMA-certified roll-off company will you be using?* API Roll-Off Services Note: a list of IWMA-certified haulers, landfills, and transfer stations can be found on the City's Construction and Demolition webpage. ALL TONNAGE LEAVING PROJECT SITE MUST BE ACCOUNTED FOR ON THIS FORM AND FAILURE TO RECYCLE AT LEAST 65% OF MATERIALS MAY RESULT IN A PENALTY OF 2% OF PROJECT VALUATION I understand that I must produce receipts listing tonnage of all materials leaving the project site, regardless of destination or method of removal. I certify that I will communicate this plan and requirements to all contractors and other personnel who may be involved in disposal of materials from this project and inform them that they must provide receipts listing the tonnage for all recycling and trash disposal. The final permit and all waste receipts must be presented prior to final sign off. I understand that failure to do so may incur a penalty of 2% of total project valuation and the City of San Luis Obispo makes the final determination of project cost and fine for failure to comply. Signature * Print Name * Chris Allen Date * 2025-06-10 Step 2: Upon Completion of Project 1.  Gather receipts listing tonnage for all materials that left the project site or a roll-off diversion report from one of the listed IWMA-certified haulers. *Please note - receipts must list tonnage as recycled or disposed. Mixed recycling receipts qualify as 70% recycling and 30% trash.  2. Email all receipts to RecycleRight@slocity.org for approval before final inspection. Include permit number, receipts/diversion report, photos of donated items (if applicable). Please allow 1-3 business days for review. 3. If approved, you will receive an email confirmation. Questions? RecycleRight@slocity.org or (805) 781-7215 Revised Dec. 2019 Design Professional’s stamp APPLICATION FOR WAIVER OF SOILS TEST FOR MINOR ADDITIONS TO ONE AND TWO-FAMILY DWELLING UNITS GENERAL INFORMATION: Project Address: ___________________________________Application #: _________________ Applicant Name: _____________________________________Phone #: ________________ BACKGROUND: Historically, quantifiable data has been created using accepted soil science methodologies by approved agencies using approved methods indicating that, in general, the soil conditions likely to be encountered throughout the City of San Luis Obispo would consist of expansive, compressible, shifting or other questionable soil characteristics. These types of soil conditions would require a complete geotechnical evaluation for moderate and major projects. PURPOSE: In order to help alleviate the burdens of time and disproportionately high cost associated with obtaining a soil test for minor residential additions up to 500 square feet to one and two family dwellings, the City of San Luis Obispo Building Division has developed a policy allowing a waiver of the soil test as specified in the California Residential Code Section R401.4. POLICY STATEMENT: Where a soils test has not been previously provided in accordance with the 2022 CRC Section R401.4; one and two family dwelling unit residential additions of 500 square feet or less, up to two stories (addition footprint area), may forego a soils test provided the applicant agrees to the following checked statements by signing and dating this application in the appropriate location at the bottom of this application:  An on-site investigation has revealed no foundation failure of the existing residence.  The type of construction proposed meets or exceeds the minimum provisions for wall and roof-ceiling construction in accordance with the 2022 CRC Chapters 6 and 8.  The foundation system proposed meets or exceeds the minimum requirements in accordance with the 2019 City of San Luis Obispo Construction and Fire Code Amendments Table 1809.7.  A minimum allowable soil bearing pressure of 1500 PSF has been utilized for the design of foundation systems as shown in the 2022 CRC Table R401.4.1.  The proposed area of work on the site does not exceed a maximum 20% slope. Print Name:_____________________________________________________________ Licensed Architect or Engineer Signature: ____________________________________________Date: _____________ Office Use Only: Approval Signature: ___________________________________Date: ______________ 619 Grove Street, San Luis Obispo, CA 93401 John Rourke 8054404973 Chris Allen 6/10/25 Stormwater Control Plan for Post Construction Requirements Exhibit 4 Application Submittal Where directions state “Done” that means no additional information or forms below that point needs to be filled out or furnished. See Exhibits for Watershed Management Zones, Basins, & Urban Sustainability Areas Use “n/a” where information requested is not applicable. If you are unsure regarding how to fill out any of the information, please come in and request assistance from a staff person. Project Information Step 1 Applicant Name: Application No: Project Name: Location Address: Location APN: Site Zoning: Project Type:  Commercial Detached Single Family Residential Industrial Multi-unit Residential Mixed Use Public Project Phase: Project Description: Total Project Site Area = (a) Total New Impervious Surface Area = (b) Total Replaced Impervious Surface Area = (c) Total Existing Impervious Area = (d) Total Impervious Area of Completed Project = (e) Net Impervious Area: (a+b) – (c-d) = OR where (c-d) is a negative number: (a+b) = Your project is NOT subject to Post Construction Requirements if… Step 2  Area (a+b) of project is < 2,500 square feet – Done OR  Area (a+b) of project is > 2,500 square feet, and is a project type listed below ( type) – Done  Road & parking surface repair – slurry & fog & crack seal, pothole & spot patching, overlay & resurfacing & other damage repair with no expansion  Road & parking shoulder grading  Road & parking cleaning, repairing, maintaining, reshaping, regarding drainage systems  Sidewalk & bike path / lane project – no other impervious surface created and runoff is directed to vegetated area  Curb & gutter improvement or replacement – no other impervious created  Underground utility project – surface replaced in kind  Utility vaults – Ex: lift stations, backflows  Fuel storage – above ground with spill containment  Photovoltaic systems – on existing impervious surface, over pervious surface with vegetated cover, buffer strip at the most down gradient row of panels  Second story – no increase in building footprint  Decks & stairs & walkways – raised with space below for drainage  Temporary structures – in place less than 6 months  Trails and pathways, where no other impervious surfaces are replaced or created, and built to direct stormwater runoff to adjacent vegetated areas. Form revised: July 12, 2016 John Rourke 619 Grove Street, San Luis Obispo, CA 93401 001-056-052 Low Density Residential (R-1) Permitting THIS PROJECT CONSISTS OF A 715 SF ADDITION TO AN EXISTING RESIDENCE. 3,589 SF 417 SF 142 SF 2,328 SF 2,603 SF 559 SF 4 4 (For Select Building Projects Less Than 1 Acre) PURPOSE: This plan can only be used for minor building projects (SFR - new, remodels, additions; and/or commercial remodels). Newly constructed commercial buildings under 2019 CalGreen Codes require the development and implementation of a WPCP similar to the standards of a State submitted SWPPP. This plan is only to serve as a guide, if the applicant elects to use it. The BMPS specified herein shall be considered just the “Minimum BMPs” and during the course of the project additional BMPs (Necessary BMPs) may be required to protect water quality. Please note that an in-fill new single family home project may require additional plan elements. This plan shall be used in accordance with CGP 2009-0009-DWQ, City Stormwater Permit & 2019 CalGreen Building Codes. GENERAL INFORMATION: WPCP Plan for Minor Building Projects) 1 of 4 Project Address: ________________________________________________________________________ Description of Work: ___________________________________________________________________ _____________________________________________________________________________________ Estimate total disturbed soil areas in square feet: __________ ** Erosion & Sediment Control Measures are required. Applicant’s Name: __________________________________ Applicant’s Tele No. (____) _____-_________ Emergency Contact: ______________________________ Tele: (___) ____-_____ Cell: (___) _____-______ Contractor’s Name: __________________________________ Contractor’s Tel No. (____) ____-_________ Contractor’s Mailing Address: ______________________________________________________________ (Street Address) (City) (State) (Zip) Type of Project - Check One Commercial / Industrial:  Alternations  New Con.  Site-work  Tenant Improvement  Other: __________________________________________________________________ Residential:  Additions  New Con.  Remodel  Other: _______________________ SCHEDULE: Anticipated Project Schedule (Calendar Days & Hours): Calendar days: __________________________________________________________________________ Hours: (From) ________________________________ (To) ______________________________________ BEST MANAGEMENT PRACTICES OR “BMPS” are procedures that help prevent pollutants from entering the City’s stormwater conveyance system and creeks. Indicate by checking ALL ANTICIPATED BMPS that must be incorporated into the project to ensure the protection of waterways and stormwater conveyance systems (i.e. gutters, streets, storm drain inlets, storm drains, catch basins, creeks, culverts and seasonal streams). Informational brochures on various project types and BMPs are available on the City website listed herein. For detailed information on the Best Management Practices listed herein refer to: Ca General Construction Permit Ca Green Building Codes Ca State Water Resources Control Board Ca Stormwater Quality Association* Caltrans Stormwater Pollution Templates Caltrans Supplement to Traffic Control Guide City of San Luis Obispo BMP Guides* City of San Luis Obispo Municipal Code City of SLO Stormwater Management Plan City of SLO Waterway Management - Plan I City of SLO Stream Management & - Plan II City of SLO Drainage Design Man. - Plan III City of SLO WPCP Guide* City Specifications Construction Industry Compliance Asst Center State Specifications - DOT http://www.waterboards.ca.gov/water_issues/programs/stormwater http://www.bsc.ca.gov/CALGreen/default.htm http://www.swrcb.ca.gov/water_issues/programs/stormwater http://www.casqa.org/ http://www.dot.ca.gov/hq/construc/stormwater/templates1.htm http://www.dot.ca.gov/hq/traffops/signtech/mutcdsupp https://bit.ly/3rWDzAa http://www.codepublishing.com/ca/sanluisobispo/ https://bit.ly/3sIS3m9 https://bit.ly/3oX9vlR https://bit.ly/3sJBE0V https://bit.ly/3uWmice https://bit.ly/3GYMpRY https://bit.ly/3t8NNOc http://www.cicacenter.org/swt/swt2.cfm?st=CA http://www.dot.ca.gov/hq/esc/oe/standards.php  Proximity to Storm Drains, Creeks & Known Underground Springs or Seeps: If the project site is within close proximity (< 150’) to a creek, storm drain inlet down gradient of the site and/or includes underground springs or seeps on site, the site plan may need to include the locations of each and additional specific BMPs may be required throughout the course of the project. Please consult with a Qualified Professional and/or Building Staff for guidance. Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 619 Grove Street, San Luis Obispo, CA 93401 EXISTING 3 BEDROOM 1 BATHROOM RESIDENCE. 1 (E) BEDROOM SHALL BE RECONFIGURED TO ACCOMMODATE THE ADDITION OF 1 BATHROOM AND CIRCULATION. THEREFORE, FINAL SF SHALL CONTAIN 5 BEDROOMS AND 2 BATHS. THIS PROJECT CONSISTS OF A 715 SF ADDITION TO AN EXISTING RESIDENCE. THIS ADDITION SHALL PROPOSE 4 ADDITIONAL BEDROOMS AND 1 BATHROOM TO THE 373 s.f. John Rourke 805 440 805Chris Allen MON-FRI 7AM 5PM 4973 WPCP Plan for Minor Building Projects 2 of 4 ANTICIPATED BMPS NOTE: A “” indicates mandatory BMPs for all projects. Good Housekeeping: Keep site clean & organized at all times.  Pre-inventory BMPs: Develop a list all materials to be used on site to determine proper storage to avoid exposure to the elements as appropriate.  Material stockpile BMPs  Chemical storage BMPs  Inclement weather – materials storage BMPs  Impervious surface sweeping BMPs  Spill management & reporting BMPs. Waste Management Plan: All waste products must be containerized & covered at all times.  Waste management BMPs  Concrete, paint, plaster residue BMPs (lined washout pit, cover during rain events)  Hazardous spill management BMPs  Landscape materials BMPs  Potential pollutant source list: Detailed list of chemicals, solvents, paints & fertilizers to be used on the site.  Painting BMPs (lined washout pit, cover daily)  Completed City C&D Plan  Portable toilet BMPs  Equipment / vehicle BMPs Erosion Control Measures - to prevent sediment from becoming dislodged due to rain & wind event.  Riparian protection BMPs  Temporary soil stabilization BMPs  Temporary curb access BMPs  Vegetation preservation BMPs  Slope stabilization BMPs  Wind erosion BMPs  Dust control BMPs  Permanent soil stabilization BMPs  Phased construction BMPs  Steep slope BMPs  Post storm erosion control BMPs Sediment Control Measures – to control & detain dislodged sediment from leaving the site.  Creek protection BMPs  Site perimeter BMPs  Sediment basin BMPs  Stabilized construction exit(s) / entrance(s)  Storm drain inlet protection BMPs  Waterway & stabilized drainage way BMPs  Rapid soil stabilization BMPs  Advanced settling devices  Post storm event sediment control BMPs Run-on & Run-off Control Measures: Overland flow of storm water both on and off-site must be effectively managed.  Stormwater run-on BMPs  Stormwater run-off BMPs Non-Stormwater Management: For work performed in the street, or to temporarily store materials in the street or on the sidewalk you must secure an encroachment permit.  Equipment tool washout BMPs  Encroachment permits  Potential non-stormwater discharge BMPs  Saw-cutting BMPs  Scheduling BMPs Site Schematic: To reflect the location of all BMPs to be used on site. For example, depict the location of all perimeter control measures, such as silt fencing or straw wattles on a schematic.  For all construction projects with outside activities. Water Efficient Landscape Plans Submittal: For new construction sites a water efficient landscape plan may be required.  Refer to Utilities Conservation Post Construction Stormwater Devices  Pre & post stormwater run-off calculation  A post construction maintenance plan  A private stormwater conveyance system agreement, and  A post construction site schematic required Inspect, Maintain, Clean, Repair & Report – all site BMP’s on active and inactive construction sites weekly. Repairs must be made as necessary. Document all activities in a log.  Weekly inspection schedule  Pre & post storm event inspections  BMP cleaning schedule  BMP maintenance schedule  BMP repair protocol  Documentation & records management protocol  Reporting protocol Project Specific BMPs  _________________________________  _________________________________  _________________________________  _________________________________  _________________________________  _________________________________ Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 WPCP Plan for Minor Building Projects 3 of 4 SITE SCHEMATIC Required for all projects that include grading activities include a reasonable sketch depicting where all required and necessary BMPs shall be placed on and off site. Be sure to include: a directional arrow, slope directions reflecting after grading is complete, scale used, the location of all structures on site, the location of all waterways on and / or abutting the site, location of closest storm drain inlet, frontage and side streets and wild lands. Note additional requirements (i.e. erosion and grading plans, post construction stormwater device elements) may be required, so please refer to City Building staff for direction. Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/ Toilet Washout Pit WPCP Plan for Minor Building Projects 4 of 4 OFFICE USE ONLY: Received By: _______________ Date: __________ Approved By: _______________ Date: ____________ Denied: By: _______________ Date: __________ Comments: ___________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ PROJECT FEE: _____________ WPCP PLAN FOR BUILDING PROJECTS LESS THAN 1 ACRE The following sections of the City Municipal Code, City Standard Specifications, Storm Water Management Regulations, Green Building Codes and Fish & Game Regulations shall be reviewed by the permittee, and the permittee shall receive approval of this Minor WPCP prior to the commencement of work on the site. Plan BMPs shall be implemented on site at all times and verified for compliance. Permittee is required to maintain a log of all routine inspections, cleanings, maintenance and repairs made to all BMPs on site at all times for review by any representative of the City upon request. Failure to adhere to the WPCP, State and Federal Regulations may result in a Notice of Violation and/or an Administrative Citation and/or a Stop Work Order issued until the site is in conformance with the requirements of this plan. APPLICABLE SPECIFICATIONS: San Luis Obispo Municipal Code 8.04 Solid Waste Disposal Title 12 Streets, Sidewalks and Public Places 12.08 Urban Storm Water Quality Management and Discharge Control 12.23 Creek Protection Ordinance 13.08.130 Stormwater & unpolluted drainage 15.04.010 All disturbed surfaces 17.17.05 Neighborhood preservation City Specifications Section 3-1.03A, Encroachment Permit 4-1.07 Work Site Maintenance 6-1.03 Storage of Materials Section 7-1.01G Water Pollution Building Regulations J103.1 & J103.2 – Grading permits required City Specifications (Continued) Section 1010B, Uniform Design Criteria – Drainage and Erosion Control 19-1.07 Sawcutting 20.3 Erosion Control Storm Water Regulations Federal Water Pollution Control Act (CWA) California Construction Stormwater Permit California Porter Cologne Act of 2002 California Green Building Codes (Chp 4 & 5) City of SLO WPCP Guide City of SLO Construction BMP Guide Fish and Game Regulations: 1600, 1602, 5650, 5651 & 5652 I agree to follow the requirements as set forth in this Guide (WPCP), the City of San Luis Obispo’s Stormwater Management Plan, the State of California’s General Construction Permit, California Green Building Codes (Chapters 4 & 5) the Federal Clean Water Act and all applicable specifications. In addition, I understand and agree to the following: (1) Dynamic Plan: additional BMPs, both temporary and permanent may be required during the course of the project at the discretion of the City Inspector(s) in order to ensure the protection of local water quality, (2) it is permittee’s obligation to take additional corrective actions when required to protect local water quality, (3) failure to comply with all the requirements could cause the permit to be revoked; the issuance of a stop work order, a notice to comply, a notice of violation and/or a citation; (4) the doing of any work under this permit shall constitute an acceptance of the provisions of this permit and all attachments and documents referenced herein, (5) a copy of this signed approved Guide shall remain at the job site at all times available for review by any public official, and (6) overland flow storm water run-off & run-on has been adequately designed for & managed. Applicant: Permit #: Check One:  Owner  Contractor  Design Professional  Legal Representative Signature: Date: If you require assistance in completing this “Plan” please contact Notes: An * indicates a construction reference source specific to Stormwater BMPs. Please refer to the City’s website for “BMP Descriptions for Minor Building Projects” handout. Use of this template plan is at the discretion of City personnel. (805) 781-7180 Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 2019 2019 03/15/2022 Chris Allen 6/10/2025 DESCRIPTION THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. SITE INFORMATION EXISTING BUILDING INFORMATION JURISDICTION ZONING APN STREET ADDRESS GROSS LOT SIZE BUILDING AREAS PROPOSED INFORMATION TWONUMBER OF STORIES R-1 (RESIDENTIAL)OCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE SPRINKLERED CLASS A ROOFINGROOF RATING TWO STORYNUMBER OF STORIES R-3 (RESIDENTIAL) / UOCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSEDFIRE SPRINKLERS CITY OF SAN LUIS OBISPO LOW DENSITY RESIDENTIAL (R-1) 001-056-052 619 GROVE STREET, SAN LUIS OBISPO, CA 93401 0.08 ACRES (3,589 SF) CLASS AROOF RATING 25 FEET ALLOWEDMAXIMUM HEIGHT PROPERTY IS NOT LOCATED WITHIN A HIGH FIRE RISK AREA OR FLOOD PLAIN AREAHAZARDS LOT COVERAGE MAX 40% = 3,589 X 0.4 = 1,287 SF. PROPOSED = SF. 1,287 / 3,589 = 35.9% (ADU EXCLUDED FROM LOT COVERAGE CALCULATIONS PER MC § 17.70.120(B)(5)) 1 SPACE PROVIDED IN DRIVEWAY PER PREVIOUS LOT SPLITPARKING LEGAL DESCRIPTION CY SLO PM 84/92-93 PAR 2 1 SPACE PROVIDED IN DRIVEWAYPARKING NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSED T1.0 Title Sheet, General Notes + Project Data Sheet Index OWNER Project Directory SOILS ARCHITECT CWA STUDIOS 1668 SYDNEY STREET SAN LUIS OBISPO. CA 93401 CONTACT: CHRIS ALLEN, AIA. 805 286 5186 Drawing Log SET ISSUE DATE REVISION Project Notes ENERGY CARSTAIRS ENERGY CALCULATIONS 2238 BAYVIEW HEIGHTS DRIVE, SUITE E LOS OSOS, CA 93402 CONTACT: TIM CARSTAIRS. 805 904 9048 Project Data T1.1 INDEX, DATA + NOTES STRUCTURAL Calgreen Mandatory Measures 1.PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL SHALL MANAGE STORMWATER DURING CONSTRUCTION. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. CALGREEN 4.106.2.2 2.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED AND SHALL COMPLY WITH THE PLUMBING FIXTURE AND FITTINGS SCHEDULE ON THIS SHEET. CALGREEN 4.303.3.1 3.AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1 - CONTROLLERS SHALL BE WEATHER- OR SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANT WATERING NEEDS AS WEATHER OR SOIL CONDITIONS CHANGE. 2 - WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). CALGREEN 4.304.1 4.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE CLOSED WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY TO PREVENT PASSAGE OF RODENTS. CALGREEN 4.406.1. 5.RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 60% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4; OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. CALGREEN 4.408.1 6.DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION PER CALGREEN 4.504.1. 7.ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS PER CALGREEN 4.504.2.1. 8.PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.2.2. 9.AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS PER CALGREEN 4.504.2.3. 10.DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED PER CALGREEN 4.504.2.4. 11.CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.3. 12.EIGHTY (80) PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERINGINSTITUTE (RFCI) FLOORSCORE PROGRAM PER CALGREEN 4.504.4. 13.PARTICLEBOARD, MEDIUM FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR OR EXTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS PER CALGREEN 4.504.5. 14.VAPOR RETARDER AND CAPILLARY BREAK OF 4” THICK BASE OF ½” OR LARGER CLEAN AGGREGATE SHALL BE INSTALLED AT SLAB ON GRADE FOUNDATIONS PER CALGREEN 4.505.2. 15.MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING SHALL BE CHECKED BEFORE ENCLOSURE PER CALGREEN 4.505.3. 16.BATHROOM EXHAUST FANS SHALL BE DUCTED TO TERMINATE OUTSIDE AND BE PROVIDED IN EVERY BATHROOM PER CALGREEN 4.506.1. 17.WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED LOUVERS OR COVERS WHICH CLOSE WHEN THE FAN IS OFF. COVERS OR LOUVERS SHALL HAVE A MINIMUM INSULATION VALUE OF R-4.2 PER CALGREEN 4.507.1. 18.PER CALGREEN 4.507.2 DUCT SYSTEMS ARE SIZED, DESIGNED, AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS: 1. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ACCA (MANUAL J) OR EQUIVALENT. 2. SIZE DUCT SYSTEMS ACCORDING TO ACCA 26-D (MANUAL D) OR EQUIVALENT. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S (MANUAL S) OR EQUIVALENT. 19.OPERATION + MAINTENANCE MANUAL TO BE SUPPLIED AT FINAL INSPECTION. 20.MANAGE STORMWATER PER CALGREEN CODE REQUIREMENTS. 4106.2 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 25.1222 Deferred Submittals / Separate Permits 1.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDER-DRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. SURVEY MBS LAND SURVEYS 3559 SOUTH HIGUERA ST. SAN LUIS OBISPO CA 93401 CONTACT: MICHAEL B STANTON 805 594 1960 ARCHITECTURAL1.ALL WORK SHALL BE IN CONFORMANCE WITH THE 2022 EDITIONS OF THE CALIFORNIA BUILDING CODES 2.ANY/ALL DEFERRED SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT AND/OR PROJECT ENGINEER PRIOR TO SUBMISSION TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL. 3.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. THE CURRENT ADOPTED STANDARDS ARE DATED MAY 2023. 4.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. 5.THE PUBLIC IMPROVEMENTS SHALL BE SUBSTANTIALLY COMPLETE TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR PRIOR TO FINAL INSPECTION APPROVALS AND/OR OCCUPANCY OF ANY BUILDING. 6.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER AND SIDEWALK OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 7.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 805 781 7554 WITH AT LEAST A 48 HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. 8.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. 9.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. 10.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED DURING ALL CONSTRUCTION AND GROUND DISTURBING ACTIVITIES PER THE CITY OF SAN LUIS OBISPO 11.TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN PERMANENT IMPROVEMENTS, PLANTINGS AND FACILITIES ARE IN PLACE. TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION APPROVALS. 12.THE EXISTING SEWER LATERAL SHALL BE TELEVISED AND APPROVED FOR REUSE OR SHALL BE REPAIRED/REPLACED. THE INSPECTION SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE UTILITIES DEPARTMENT PRIOR TO ISSUANCE OF A BUILDING PERMIT. 13.ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE VERTICAL AND GREATER AND AREAS USED TO CONVEY CONCENTRATED DRAINAGE SHALL BE PREPARED AND MAINTAINED TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED NO LATER THAN 30 DAYS PRIOR TO A REQUEST FOR FINAL INSPECTION APPROVAL. 14.REMODELING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS A VIOLATION OF CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELERS AND PAINTERS ARE REQUIRED TO USE "LEAD-SAFE" WORK PRACTICES PURSUANT TO TITLE 17, CA CODE OF REGULATIONS SECTION 36050. 15.PRIOR TO ANY DEMOLITION OR GRADING THE CONTRACTOR SHALL PROTECT ANY TREES ADJACENT TO THE WORK ZONE. 16.THE MANDATORY PROVISIONS OF CALGREEN CHAPTER 4 SHALL BE APPLIED TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. CALGREEN 301.1.1 17.ON AND AFTER JANUARY 1, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. CALGREEN 301.1.1 18.APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER ORDINANCE OR LAW. CBC 105.4 19.THIS PROJECT IS LOCATED IN THE HIGH FIRE SEVERITY ZONE AS PER CITY OF SAN LUIS OBISPO California Building Code Chapter 7A Req. THE CITY OF SAN LUIS OBSIPO IS CONSIDERED A "COMMUNITY AT RISK" DUE TO THE THREAT OF WILDFIRE IMPACTING THE URBAN COMMUNITY. THE CITY SHALL CONTINUE TO ENHANCE THE FIRE SAFETY AND CONSTRUCTION CODES FOR NEW BUILDINGS IN ORDER TO REDUCE THE RISK OF URBAN FIRES THAT MAY RESULT FROM WILDFIRES. NEW BUILDINGS CITYWIDE SHALL INCORPORATE THE FOLLOWING CONSTRUCTION METHODS AND MATERIALS: IGNITION RESISTANT EXTERIOR WALL COVERINGS; FIRE SPRINKLER PROTECTION IN ATTIC AREAS (AT LEAST ONE "PILOT HEAD"); EMBER RESISTANT VENT SYSTEMS FOR ATTICS AND UNDER FLOOR AREAS, PROTECTED EAVES AS IDENTIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7A. CRC R337.1.2. STORK, WOLFE & ASSOCIATES 555 CHORRO ST. SUITE A1 SAN LUIS OBISPO, CA 93401 CONTACT: JUSTIN WOLFE, PE. PH: 805 548 8604 STRUCTURAL AS1.1 ARCHITECTURAL SITE T1.2 A3.1 EXISTING BUILDING ELEVATIONS A5.2 ARCHITECTURAL DETAILS S0.1 STRUCTURAL GENERAL NOTES S1.4 TYPICAL DETAILS S1.2 TYPICAL DETAILS S2.2 S2.3 ROOF FRAMING PLAN SECOND FLOOR FRAMING PLAN S0.2 STRUCTURAL GENERAL NOTES S1.1 TYPICAL DETAILS A4.1 PROPOSED BUILDING SECTIONS S1.3 TYPICAL DETAILS S2.1 FOUNDATION PLAN S3.1 STRUCTURAL DETAILS CALGREEN MANDATORY MEASURES G r o v e S t r e e t R e s i d e n t i a l A d d i t i o n 6 1 9 G r o v e S t r e e t , S a n L u i s O b i s p o , C A 9 3 4 0 1 A5.1 ARCHITECTURAL DETAILS N/A T1.3 CALGREEN MANDATORY MEASURES Vicinity Map S3.3 STRUCTURAL DETAILS Construction Documents for SV1.1 EXISTING TOPOGRAPHIC SURVEY PROJECT LOCATION CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s BUILDING AREAS (EXISTING) (PROPOSED) PRIMARY RESIDENCE (EXISTING) 1,287 SQ. FT. PROPOSED ADU GROUND FLOOR 490 SQ. FT. SECOND FLOOR 430 SQ. FT. TOTAL (INCLUDING EXISTING RESIDENCE) 2,292 SQ. FT. N/ASOILS REPORT JOHN ROURKE 163 SERRANO HEIGHTS DRIVE SAN LUIS OBISPO. CA 93405 CONTACT: JOHN ROURKE. PH: 805 440 4973 A2.1 PROPOSED FLOOR PLANS + ROOF PLAN A3.2 PROPOSED BUILDING ELEVATIONS AS1.2 ARCHITECTURAL SITE DETAILS Standard Public Works Notes a.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. (THE CURRENT ADOPTED STANDARDS ARE DATED SEPTEMBER 2022. b.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY, WITHIN CITY EASEMENTS, OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. c.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK, OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. d.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST A 48-HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. e.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. f.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. g.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. h.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. Stormwater Compliance Summary THE PROJECT IS NOT A REGULATED PROJECT SUBJECT TO REGIONAL WATER QUALITY CONTROL BOARD RESOLUTION R3-2013-0032 “POST CONSTRUCTION STORMWATER MANAGEMENT REQUIREMENTS FOR DEVELOPMENT PROJECTS IN THE CENTRAL COAST REGION” BASED ON THE FOLLOWING: ☒PROJECT DOES NOT CREATE AND/OR REPLACE 2,500 SQUARE FEET OR MORE OF IMPERVIOUS AREA ☐PROJECT TYPE IS LISTED IN SECTION B.1.B (STATE WHICH): Applicable Governing Codes: 2022 2022 2022 CALIFORNIA BUILDING CODE, VOLUMES 1+2 CALIFORNIA ELECTRIC CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA GREEN BUILDING CODE CALIFORNIA FIRE CODE CALIFORNIA ENERGY CODE CALIFORNIA RESIDENTIAL CODE 2022 2022 2022 2022 2022 SAN LUIS OBISPO MUNICIPAL CODE NOT TO SCALE T1.4 ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS T1.0 A5.3 FIRESTOPPING DETAILS MEP1 ELECTRICAL FLOOR PLAN + NOTES MEP2 MEP CALCULATIONS T1.1 Calgreen Mandatory Measures N/A N/A N/A Y Y ALL Y OWNER Y ALL Y CONT Y OWNER Y CONT Y CONT Y CONT Y OWNER Y OWNER CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s T1.2 Calgreen Mandatory Measures N/A N/A Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y OWNER Y CONT Y CONT Y CONT CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s T1.3 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s T1.4 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s SV1.1 Existing Topographic Survey CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue dateproject:applicant / owner:CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 25.0800 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o sSLO CITY PERMIT No. BLDG-1538-2025CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A RCHITE C TSTATE OF CA L I F O R N IAAttached Residential ADU619 Grove St.San WALL .5' HIGH +/- 22'-11 1/128" BRICK PAVERS (P) 10' WIDE ACCESS, PEDESTRIAN EGRESS, NO PARKING, & UTILITY EASEMENT HELD RECORD DISTANCE FROM SOUTH TO ESTABLISH SOUTHEAST CORNER OF BLOCK 1 N1°57'52"E 64.00'M&R6EXISTING OUT BUILDING TO BE REMOVED PRIOR TO RECORDING MAPN1°57'52"E 50.00'*M&D1N88°04'24"W 119.99'*M&D1 N88°04'24"W 119.99'*M&D1 N1°57'52"E 50.00'*M&D1N1°57'52"E 50.00' 168420 Architectural Site Plan11/8" = 1'-0" AND MAINTAINING THE INTEGRITY OF THE PROPERTY AND SURROUNDING INFRASTRUCTURE. 3 AS1.2 23 2" SCHEDULE 40 PVC DRAIN PIPE 14 7 10 25 20 18 328.9' INV. 337.5' INV. 329.7' INV. 331.0' FG. 331.0' FG. 332.75' FG. 330.6' TG. 329.9' TG. 330.9' FG.10'-9"5'-2 3/4"10'-9 1/4"5'-0"SETBACKS5'-0"SETBACKS5'-0 3/4" 5'-0" SETBACK 6" SEISMIC GAP 328.9' INV. 329.9' TG. 327.9' INV. 327.9' INV. 338.5' OUTLET 338.5' TG.332.75' FS. Architectural Site Details CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue dateproject:applicant / owner:CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 25.0800 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o sSLO CITY PERMIT No. BLDG-1538-2025CHRISTOPHER W. ALLEN C35818 EXP. 09.30.25LICENSED A RCHITE C TS TATE OF C A L I F O R N IAAttached Residential ADU619 Grove St.San Luis Obispo, CA 93401John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NC12/##/25 Liberty Grinder Pump Specification1N.T.S. DensGlass Installation Guide - Fastening and Framing N.T.S.3 Sidewalk Underdrain N.T.S.3 AS1.2 Proposed Floor Plans, Roof Plan, and Schedules CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s 0 1 2 84 1/4" = 1'-0" Proposed First Floor Plan1 0 1 2 84 1/4" = 1'-0" Proposed Second Floor Plan2 A2.1 Floor Plan Reference Notes 1.HARDWOOD VANITY CABINETS 20" DEEP WITH FINISH COUNTER HEIGHT OF +36" A.F.F. . 2.QUARTZITE COUNTERTOP. USE 2CM SLAB THICKNESS AS DROP EDGE CEASARSTONE, OR EQUAL. COLOR TO BE SELECTED BY OWNER. 3.SINK: KOHLER, OR EQUAL. FAUCET: HANSGROHE BATHROOM FAUCET, OR EQUAL. 4.MIRROR FROM TOP OF COUNTER TO TOP OF CIELING OR PER OWNERS SELECTION. 5.SHOWER HEAD: KOHLER, OR EQUAL. CONTROLS: THERMOSTATIC/PRESSURE BALANCE MIXING VALVE TO PROVIDE SCALD + THERMAL SHOCK PROTECTION. 6.66" PRE-FABRICATED FIBERGLASS TUB. TOP @ 18" A.F.F.. 7.TOILET: LOW-FLOW AMERICAN STANDARD CADET 3, OR EQUAL. 8.GUARDRAILS; SHALL HAVE A MINIMUM HEIGHT OF 42". INTERMEDIATE RAILINGS SHALL BE SPACED AT A MAXIMUM OF 3-3/4". HANDRAILS; SHALL HAVE A HEIGHT OF 36" WHERE LOCATED IN STAIRWAYS. A MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT IS 31-1/2" WHERE A HANDRAIL IS INSTALLED ON ONE SIDE OF THE STAIRWAY, AND 27" WHERE HANDRAILS ARE INSTALLED ON BOTH SIDES. 9.STAIRS, 7-3/4" MAX RISER / 10" MIN. TREAD DEPTH. TO BE IN COMPLIANCE WITH CRC R311.7. 10.NEW FIXTURES PER CALGREEN MANDATORY MEASURES. 11.INFILL WINDOWS IN EXISTING RESIDENCE WITH OPAQUE WALL. 12.6" SEISMIC GAP BETWEEN EXISTING RESIDENCE AND PROPOSED ADU AS SHOWN, REFERENCE DETAIL A ON THIS SHEET FOR MORE DETAIL. 0 1 2 84 1/4" = 1'-0" Proposed Roof Plan3 Legend X NEW 2X4 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS NEW 2X6 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS DOOR / WINDOW CALLOUTS; SEE DOOR & WINDOW SCHEDULE THIS SHEET FOR DETAILS 1-HR RATED ASSEMBLY BETWEEN NEW ACCESSORY DWELLING UNIT AND EXISTING RESIDENCE. NEW RATED WALL SHALL EXTEND FROM CONCRETE SLAB TO BOTTOM OF PROPOSED ROOF SHEATHING IN ALL LOCATIONS. REFERENCE DETAIL 4 & 6 ON A5.2 FOR ADDITIONAL INFORMATION. WINDOW AND DOOR NOTES: 1.ALL EXTERIOR DOORS SHALL BE WEATHER-STRIPPED AND SHALL FEATURE WATER-RESISTANT THRESHOLDS AND/OR DOOR BOTTOMS 2.THRESHOLDS SHALL BE 3/4" MAXIMUM AT SLIDERS AND 1/2" MAXIMUM FOR OTHER DOORS. 3.TEMPERED GLAZING SHALL BE PROVIDED WHERE INDICATED IN THESE PLANS IN ACCORDANCE WITH THE REQUIREMENTS FOR HAZARDOUS LOCATIONS [CBC 2406.3] 4.LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-½" LOWER THAN TOP OF THRESHOLD. (THE LANDING / FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 7-¾" BELOW TOP OF THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR.) [R311.3.1] 5.PROVIDE LOCKSETS AND DEADBOLTS ON ALL EXTERIOR HINGED DOORS. 6.WINDOWS THAT SERVE AS A REQUIRED MEANS OF EGRESS ARE DENOTED ON THE EXTERIOR ELEVATIONS. EGRESS WINDOWS SHALL HAVE A MAX DIMENSION OF 44" TO THE OPENING ABOVE THE FLOOR, PROVIDE 5.7 SQUARE FEET OF CLEAR EGRESS AREA WITH 24" MIN. HEIGHT AND 20" MIN. WIDTH. Window Schedule WIDTH HEIGHT FRAMETYPE A 4'-0" B HEADER +80" Door Schedule WIDTH HEIGHT FRAME PANELTYPE 6'-8"EXTERIOR - HINGED 2 1 # # VINYL4'-0" GLAZED, TEMPEREDWOOD 3'-8"2'-6" +80" 3'-0" 6'-8" INTERIOR - HINGED 3 S.C. SLABWOOD 2'-8" VINYLSLIDING SLIDING INTERIOR - HINGED S. CLASS "A" COMP SHINGLE ROOFING TO MATCH EXISTING. PRODUCT SHALL MEET OR EXCEED UL 790 (CLASS A FIRE RESISTANCE STANDARD). A DRIP EDGE SHALL BE PROVIDED AT EAVES AND RAKE EDGES OF SHINGLE ROOFS PER R905.2.8.5. 3.METAL GUTTER AND DOWNSPOUT PROVIDED, AS REQUIRED. LOWER ROOF DRAINS TO CONNECT TO LEADERS DOWN TO SITE DRAINAGE CONNECTIONS. INLET SHALL BE EQUIPPED WITH A LEAF STRAINER TO PROHIBIT DEBRIS FROM ENTERING THE DOWNSPOUT. 1 1 2 2 2 3 3 1'-7"1'-10 1/2"1'-10 1/2"1'-10 1/2"1'-8"1'-8"3'-2" 3'-2"3'-1"6" SEISMICGAPLIVING ROOM 101 KITCHEN 102BATH 105 BEDROOM 106 LAUNDRY 104 HALL 103 BATH 203 BEDROOM 202 HALL 201 1/A4.11/A4.1BEDROOM 204 BEDROOM 205 A3.1 Existing Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r D 3/4 D 3/4 D 4 D 1 A 2 F 2 F 6 C 8 - 10 - A3.2 Proposed Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r 4 D D 3/4 D 4 4 D 6 C 1 A 10 E 10 E 2 F A4.1 Proposed Building Sections CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL BE NOT LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698 MM) WHERE HANDRAILS ARE INSTALLED ON BOTH SIDES. R311.7.5.1 RISERS THE RISER HEIGHT SHALL BE NOT MORE THAN 73/4 INCHES (196 MM). THE RISER HEIGHT SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAD) FROM THE VERTICAL. AT OPEN RISERS, OPENINGS LOCATED MORE THAN 30 INCHES (762 MM), AS MEASURED VERTICALLY, TO THE FLOOR OR GRADE BELOW SHALL NOT PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE. R311.7.5.2 TREADS THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). R311.7.5.3 NOSINGS NOSINGS AT TREADS, LANDINGS AND FLOORS OF STAIRWAYS SHALL HAVE A RADIUS OF CURVATURE AT THE NOSING NOT GREATER THAN 9/16 INCH (14 MM) OR A BEVEL NOT GREATER THAN 1/2 INCH (12.7 MM). A NOSING PROJECTION NOT LESS THAN 3/4 INCH (19 MM) AND NOT MORE THAN 11/4 INCHES (32 MM) SHALL BE PROVIDED ON STAIRWAYS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST NOSING PROJECTION BY MORE THAN 3/8 INCH (9.5 MM) WITHIN A STAIRWAY. R311.7.9 ILLUMINATION STAIRWAYS SHALL BE PROVIDED WITH ILLUMINATION IN ACCORDANCE WITH SECTIONS R303.7 AND R303.8. CHAPTER 7 WALL COVERING R702.3.7.1 LIMITATIONS WATER-RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER, OR IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. California Residential Code Architectural Details CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r and Firestopping NOT TO SCALE Bi-Pass Door - Head and Jamb Typical Jamb, Head, and Sill Installation @ Exterior Windows + Doors 3" = 1'-0" 5 1 Through Wall Penetrations and Firestopping N.T.S.4 SYSTEM NO. W-L-1054NOT TO SCALE AND EXISTING SFR NEW ROOF CAVITY AND FRAMING EXTERIOR RATED GYPUSM BOARD PER ASSEMBLY GALVANIZED "Z" BAR COUNTER FLASHING 18" 6" 6" 8 3" = 1'-0" CAD FILE CWA JOB NO DRAWN BY PLOT DATE 2020 1 sheet: sheet data: revision: sheet title: REV DESCRIPTION BYISSUE DATEproject:applicant / owner:CWA christopher william allen 1 SYDNEY STREET, SLO, CA 3401 EMAIL CWA.ARCH GMAIL.COM TELEPHONE 0.2.1 AIA, LEED AP, C-31 2.000 legal stuff: THE USE OF THES E PLANS AND SPECIFICAT IONS SHALL BE RESTRICTED TO THE USE OF THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE UNLESS OTHERWISE APPROVED BY THE A RC HITECT. TITL E TO T HES E P LA NS AN D S PE CIFI CA T IO NS REMAINS WITH CWA STUDIOS WITHOUT PREJUDICE. VISUAL CONTAC T W ITH TH E SE P LANS AND S PE CI F ICATI O NS S HA LL CONSTITUTE PRIMA FACE EVIDENCE OF THE ACCEPTANCE OF T HES E R EST R I CT ION S. C 2 02  C W A S T U DI O SSLO CITY PERMIT No. BLDG-1538-2025CHRISTOPHER W. ALLEN C31 EXP. 0.30.2LIC E N S E D A RCHITE C TS TATE OF C A L I F O R N IAAttached Residential ADU619 Grove St.San Luis Obispo, CA 93401John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NC12/ªª/2 Firestopping Details A5.3 GFI +42 GFI +42 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s WHOLE-BUILDING VENTILATION REQUIREMENTS (FROM ASHRAE 62.2) AT LEAST ONE MECHANICAL VENTILATION SYSTEM IN THE BUILDING MUST BE DESIGNATED FOR USE IN COMPLIANCE WITH THE WHOLE- BUILDING VENTILATION REQUIREMENT. ALTERNATIVELY, THE SUM OF THE RATED AIR FLOWS FROM MULTIPLE FANS CAN BE UTILIZED TO MEET THE REQUIRED WHOLE BUILDING VENTILATION AIRFLOW. THE SYSTEM(S) MUST DELIVER CONTINUOUS VENTILATION AIRFLOW AT A RATE GREATER THAN OR EQUAL TO THE RATE SPECIFIED IN EQUATION 4.1a, AND FAN SONE RATINGS MUST NOT EXCEED 1.0. FOR DWELLING OCCUPANT DENSITIES KNOWN TO BE GREATER THAN (NBR + 1), THE RATE SHALL BE INCREASED BY 7.5 CFM FOR EACH ADDNL PERSON. Whole House Ventilation Calculation FLOOR AREA (SF)NBR OF BR QFAN (cfm) 920 4 50.40 MEP2 MEP Calculations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 25.1222 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 5 c w a s t u di o s Residential Load Calculations RESIDENTIAL LOAD CALCULATIONS (NEC 220.82) OPTIONAL METHOD NEC 220-30 As an optional method, the STANDARD METHOD, found in ARTICLE 220 of the National Electric Code, may be used 1 GENERAL LIGHTING NOTES SF X 3 VA / SF 920 SF 2760 VA SMALL APPLIANCE LOADS - 220-16 (a) (MIN. 2)1500 VA 3000 VA LAUNDRY LOADS 1500 VA 1500 VA SUBTOTAL 7260 VA 2 COOKING EQPT. LOADS - (NAMEPLATEVALUE) RANGE 5000 VA 5000 VA COOKTOP --VA 0 VA OVEN 0 VA 0 VA SUBTOTAL 5000 VA 3 ELECTRICAL DRYER 220-18 (NAMEPLATE, 5,00 VA MIN) DRYER 5000 VA 5000 VA SUBTOTAL 5000 VA 4 FIXED APPLIANCE LOADS- 230-30(b3) DISHWASHER 0 VA 0 VA DISPOSAL 1140 VA 1140 VA COMPACTOR --VA 0 VA WATER HEATER 0 VA 0 VA HYDROMASSAGE BATHTUB --VA 0 VA MICROWAVE 1500 VA 1500 VA BUILT -IN VACUUM 0 VA 0 VA SUBTOTAL 2640 VA 5 OPTIONAL SUBTOTAL (ADD ALL OF THE ABOVE TOTALS)19900 VA 6 APPLYING DEMAND FACTORS -TABLE 220-30 FIRST 10,000VA @ 100%10,000 VA REMAINING VA @ 40% (SUBTOTAL ABOVE - 10,000) X 40%3960 VA 7 HEATING OR AC LOAD - TABLE 220-30 10000 LARGER OF THE HEATING OR AC LOAD 0 VA 8 POOL PANLE/EQUIPMENT 0 VA 9 OPTIONAL TOTAL VOLT AMPS (ADD TOTAL FROM LINE 6+7)23960 VA 10 MINIMUM SERVICE SIZE (OPTIONAL LOAD TOTAL VA /240 VOLTS) =100 AMPS SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS A.PURPOSE 1.THE FOLLOWING INFORMATION INCLUDES THE BASIC PERMIT APPLICATION REQUIREMENTS FOR A 120/240 VOLT SINGLE PHASE ELECTRICAL SERVICE RATED GREATER THAN 200 AMPERES, BUT NOT OVER 600 AMPERES, INSTALLED ON A SINGLE FAMILY RESIDENTIAL LOT. 2.CAUTION: THIS HANDOUT AND THE NATIONAL ELECTRICAL CODE ARE NOT INTENDED AS DESIGN SPECIFICATIONS NOR INSTRUCTION MANUALS FOR UNTRAINED PERSONS. NEC 90.1(C). THE NATIONAL ELECTRICAL CODE REQUIRES QUALIFIED PERSONS TO DESIGN ELECTRICAL INSTALLATIONS. B.SCOPE 1.IN GENERAL, THE ELECTRICAL EQUIPMENT AND WIRING UNDER THE OWNERSHIP OR RESPONSIBILITY OF THE SERVING ELECTRICAL UTILITY IS NOT REGULATED BY THE NEC. THE APPLICABLE SERVING UTILITY MUST BE CONTACTED FOR ANY ADDITIONAL REQUIREMENTS. 2.UNLESS OTHERWISE NOTED, CODE REFERENCES SHALL BE FROM THE 2005 NATIONAL ELECTRICAL CODE (NFPA 70 - NEC) AS AMENDED BY THE CURRENT CITY ADOPTED ORDINANCE. 3.THIS SHOULD NOT BE CONSIDERED AS A COMPLETE LIST OF CODE REQUIREMENTS. ELECTRICAL INSPECTIONS MUST BE PERFORMED AND ”APPROVED” BEFORE THE WORK IS CONSIDERED COMPLETED BY THE CITY OF SAN LUIS OBISPO. C.DEFINITIONS (NEC ARTICLE 100) 1.QUALIFIED PERSON – ONE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE EQUIPMENT AND THE HAZARDS INVOLVED, I.E. LICENSED ELECTRICAL ENGINEER OR LICENSED ELECTRICAL CONTRACTOR. 2.SERVICE (ELECTRICAL) – THE CONDUCTORS AND EQUIPMENT FOR DELIVERING ELECTRIC ENERGY FROM THE SERVING UTILITY TO THE WIRING SYSTEM OF THE PREMISES SERVED. 3.SERVICE POINT – THE POINT OF CONNECTION BETWEEN THE FACILITIES OF THE SERVING UTILITY AND THE PREMISES WIRING. 4.SERVICE EQUIPMENT – ALSO REFERRED TO AS THE SERVICE ENTRANCE SECTION OR “SES”. THE NECESSARY EQUIPMENT USUALLY CONSISTING OF CIRCUIT BREAKERS OR SWITCHES AND FUSES CONNECTED TO THE LOAD END OF SERVICE CONDUCTORS TO A BUILDING OR OTHER STRUCTURE, OR AN OTHERWISE DESIGNATED AREA, AND INTENDED TO CONSTITUTE THE MAIN CONTROL AND CUTOFF SUPPLY. 5.SUBSERVICE – THE NECESSARY EQUIPMENT CONNECTED TO THE LOAD SIDE OF SERVICE EQUIPMENT 6.SUB-PANEL OR PANEL – A TRADE TERM FOR SUBSERVICE PANELBOARDS OR LOAD CENTERS. 7.PREMISES WIRING – ALL ON-SITE WIRING FROM THE SERVICE POINT TO THE END UTILIZATION OUTLET. 8.FEEDERS – ALL CIRCUIT CONDUCTORS BETWEEN THE SERVICE EQUIPMENT AND THE FINAL OVERCURRENT DEVICE (CIRCUIT BREAKER). D.LOCATION 1.ELECTRICAL UTILITY: WHILE IN THE PLANNING STAGE AND BEFORE PERFORMING ANY WORK, CONTACT THE SERVING ELECTRICAL UTILITY REGARDING THE LOCATION OF THE SERVICE POINT, INSTALLATION REQUIREMENTS, EQUIPMENT TYPE AND REQUIRED CLEARANCES. 2.CLEARANCES IN FRONT OF THE SES AND SUB-PANELS NEC 110.26: (a)A MINIMUM THREE (3) FOOT DEEP LEVEL SPACE IN FRONT OF THE EQUIPMENT. NEC 110.26(A)(1). (b)MINIMUM 2’-6” (30”) WIDE SPACE OR WIDTH OF EQUIPMENT, WHICHEVER IS GREATER. NEC 110.26(A)(2). (c)EQUIPMENT DOORS MUST BE ABLE TO FULLY OPEN 90 DEGREES. NEC 110.26(A)(2). (d)MINIMUM 6’-6” HIGH OR TOP OF THE EQUIPMENT, WHICHEVER IS HIGHER. NEC 110.26(A)(3), 110.26(E). (e)THE ACCESS AND WORK SPACE SHALL NOT BE USED FOR STORAGE. NEC 110.26(B). 3.OUTDOOR/WATER/MOISTURE – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO WATER OR MOISTURE ON A REGULAR BASIS OR IN LARGE QUANTITIES, I.E. WHERE EXPOSED TO LAWN SPRINKLERS OR BELOW A ROOF SCUPPER. NEC 110.26(F). 4.VEHICULAR TRAFFIC – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO DAMAGE BY VEHICULAR TRAFFIC. NEC 110.26(F). 5.CLOTHES CLOSETS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN CLOTHES CLOSETS. NEC 240.24(D). 6.BATHROOMS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN BATHROOMS. NEC 240.24(E). 7.SEPARATE BUILDINGS – REFER TO NEC 225.30 PART B, 250.32, 250.50, 250.104 FOR REQUIRED DISCONNECTING MEANS, GROUNDING, AND BONDING. E.PERMIT AND PLAN REQUIREMENTS 1.SITE (PLOT) PLAN: PROVIDE A SIMPLE SITE PLAN (MINIMUM SCALE 1:40) INDICATING THE LOCATION OF EXISTING BUILDING(S), STRUCTURES, FENCES, POOLS, SPAS, ETC, AND THE LOCATION OR AREA WHERE THE SERVICE AND PANELBOARDS ARE TO BE INSTALLED. REFER TO THE SITE PLAN INCLUDED. 2.SINGLE LINE (FEEDER) DIAGRAM NEC 215.5. – DIAGRAM(S) ARE INCLUDED FOR REVIEW. 3.LOAD CALCULATIONS NEC 220 – PROVIDE ELECTRICAL LOAD CALCULATIONS FOR THE ELECTRICAL SERVICE (SES) AND EACH SUB-SERVICE PANEL TO BE INSTALLED. THE STANDARD OR OPTIONAL METHOD MAY BE USED. A COMPLETED OPTIONAL METHOD IS ATTACHED. EXAMPLES OF BOTH METHODS ARE LOCATED IN APPENDIX D OF THE NEC. F.INSPECTION REQUIREMENTS THE INSPECTION CARD LISTS IN DETAIL THE REQUIRED INSPECTIONS. THE FOLLOWING INSPECTIONS ARE FOR YOUR INFORMATION AND MAY VARY DEPENDING UPON THE INSTALLATION. 1.ROUGH ELECTRICAL 2.FINAL ELECTRIC 3.TEMPORARY ELECTRIC IN PERMANENT POSITION IS AN OPTION THAT CAN ALSO BE USED. AN APPLICATION AND REFUNDABLE DEPOSIT ARE REQUIRED. 4.FOR SERVICE SHUT DOWNS, PLEASE CALL INSPECTION SERVICES TO ARRANGE AN INSPECTION. Electric Panel Requirements / Calculations Basis of Design - Plumbing Calculation EXISTING RESIDENCE. EXISTING WATER PRESSURE AT HOSE BIB CLOSEST TO WATER METER MEASURES 65 PSI. FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 1 1/2"2.5 2.5 LAV SINK 1 1/2"1.5 1.5 KITCHEN SINK 1 1/2"1.5 1.5 COMBINATION TUB / SHOWER 1 1/2"4.0 4.0 DISHWASHER 1 1/2"1.5 1.5 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 17.5 PROPOSED ADU FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 2 1/2"2.5 5.0 LAV SINK 2 1/2"1.5 3.0 KITCHEN SINK 1 1/2"1.5 1.5 COMGO BATH/SHOWER 2 1/2"4.0 8.0 SHOWER 2 1/2"2.0 4.0 DISHWASHER 0 1/2"1.5 0.0 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 20.0 TOTAL (EXISTING RESIDENCE + ADU)37.5 PLUMBING CALCULATION NOTES: 1.THE EXISTING WATER METER IS A 3/4" SIZE WITH A 3/4" BUILDING SUPPLY LINE ON THE CUSTOMER SIDE OF THE METER. USING TABLE 610.3/610.4 FROM THE 2022 CA PLUMBING CODE TO DETERMINE PROPOSED AND EXISTING “WATER SUPPLY FIXTURE UNITS” (WSFU), THE COMBINATION OF EXISTING AND PROPOSED FIXTURE UNITS DOES NOT FALL WITHIN THE ACCEPTABLE RANGE, AND THEREFORE: 2.THE EXISTING 3/4" WATER METER SHALL REMAIN WHILE THE 3/4" BUILDING SUPPLY LINE SHALL BE UPGRADED WITH A 1" BUILDING SUPPLY LINE IN ORDER TO BE ADEQUATE FOR THE PROPOSED ADU. S0.1 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S0.2 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.1 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.2 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.3 Typical Details Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.4 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.1 Foundation Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.2 Second Floor Framing Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.3 Roof Framing Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S3.1 Structural Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S3.2 Structural Details Calculations Job #: SWA 25053.01 Date: 12/01/25 Contents Load Tables 1 Roof & Floor Framing 2-6 Wall Stud / Post Design 7-20 Lateral Design 21-37 Foundation Design 38 Structural Calculations For RESIDENTAIL ADDITION 619 Grove St. San Luis Obispo, CA 93401 Client: CWA Studios Load Tables: Roof Framing Roof Comp Shingles =6.00 psf 5/8" plywood sheathing =1.90 psf 2x12 @ 16" o.c. =3.10 psf Insulation =0.50 psf Gyp Ceiling =3.00 psf Subtotal = 14.50 psf Slope correction for 2:12 =1.01 Subtotal =14.7 psf misc (sprinklers, overframing etc.) =3.30 psf Total Roof DL = 18.0 psf Roof Lr =20.00 psf Floor Framing Flooring =5.00 psf 3/4" Plywd. =2.30 psf 2−2x10 @ 16" o.c. =3.40 psf gyp ceiling / Plaster =3.00 psf Misc. =3.30 psf Total Floor DL = 17.00 psf Floor LL =40.00 psf Exterior Walls Stucco / Stone Veneer =10.00 psf Plywood sheathing =1.50 psf 2x6 wood studs @ 16" o.c. =1.50 psf Insulation =0.50 psf 5/8" gypboard =3.00 psf Misc. =1.50 psf Total Exterior Wall DL = 18.00 psf 2x6 wood studs @ 16" o.c. =1.50 psf Insulation =0.50 psf 5/8" gypboard [two sides] =6.00 psf Misc. =2.00 psf Total Interior Wall DL = 10.00 psf Interior Walls PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 1 2 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: ROOFDescription : Wood Beam Design :RR1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.669 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 9.500 inft 38.69 psi Fb : Allowable : 1,293.75 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.172 : 1 0.000 ft 864.95 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.275 in Transient Upward 0.000in Total Downward 0.523 in Total Upward 0.000 in 0.23 0.250.23 0.25 Ratio 828 435Ratio LC: Lr Only LC: +D+Lr LC:LC: Wood Beam Design :RR2 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 2.0 ft .Design Summary Max fb/Fb Ratio =0.070 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 2.500 inft 10.58 psi Fb : Allowable : 1,293.75 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.047 : 1 4.067 ft 90.07 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.002 in Transient Upward 0.000in Total Downward 0.004 in Total Upward 0.000 in 0.09 0.100.09 0.10 Ratio 9999 9999Ratio LC: Lr Only LC: +D+Lr LC:LC: 3 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Wood Beam Design :RB1 - RIDGE BEAM Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 (1) Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 (1) Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 5.0 ft .Design Summary Max fb/Fb Ratio =0.494 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 6.000 inft 36.77 psi Fb : Allowable : 1,125.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.163 : 1 11.080 ft 555.89 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.071 in Transient Upward 0.000in Total Downward 0.134 in Total Upward 0.000 in 0.54 0.600.54 0.60 Ratio 2039 1073Ratio LC: Lr Only LC: +D+Lr LC:LC: 4 5 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: FLOORDescription : Wood Beam Design :FJ1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-22 / IBC 2024 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.755 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 7.375 inft 43.40 psi Fb : Allowable : 1,035.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.241 : 1 13.816 ft 781.91 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.200 in Transient Upward 0.000in Total Downward 0.285 in Total Upward 0.000 in 0.17 0.390.17 0.39 Ratio 884 620Ratio LC: L Only LC: +D+L LC:LC: Wood Beam Design :FB1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-22 / IBC 2024 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.032 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 2.250 inft 3.81 psi Fb : Allowable : 990.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.021 : 1 0.000 ft 31.19 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.001 in Transient Upward 0.000in Total Downward 0.001 in Total Upward 0.000 in 0.05 0.120.05 0.12 Ratio 9999 9999Ratio LC: L Only LC: +D+L LC:LC: 6 Wind Criteria ASCE 7−16 − Chapter 30 ASCE 7−16 Design Wind Loads [Component & Cladding]  Wind Design Force: P=qh (GCp -GCpi)(30.3−1) qh = 0.00256KzKztKdKeV2 26.10−1 Kz =0.66 (Exp. B) Sect 26.10.1 and Table 26.10−1 Kzt =1.00 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.00 mph Fig. 26.5−1B qz =12.4 psf (lrfd) At =10.0 ft2 min. GCp =1.0 (Zone 4 &5) Fig.30.3−1 GCp =−1.1 (Zone 4) Fig.30.3−1 GCp =−1.4 (Zone 5)Fig.30.3−1 GCpi =0.18 26.13 & Table 26.13−1 P= −15.90 psf (Zone 4) P= −19.63 psf (Zone 5) PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 7 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x4Analysis Method : 11.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0 psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 11.25 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 12.801 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 11.250 ft, D = 0.150 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.3541 Location of max.above base 5.587 ft Applied Axial 0.1628 k Applied Mx 0.1107 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 16.875 psi 180.0Allowable Shear psi 0.06250 : 1 Bending Compression Shear Location of max.above base 11.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.03938 k Bottom along Y-Y 0.03938 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.2974 in at 5.663 ft above base for load combination :+D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 305.488 psi Other Factors for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 11.250 ft0.217 ft0.1021X Axis +D+L 1.000 PASS PASS5.587 0.06250 11.250 ft0.197 ft0.3541X Axis +D+0.750L 1.250 PASS PASS5.587 0.03750 11.250 ft0.159 ft0.2326X Axis +0.60D 1.600 PASS PASS0.0 0.0 11.250 ft0.125 ft0.05973X Axis . 8 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k)Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.163 +D+L -0.039 0.163-0.039 +D+0.750L -0.030 0.163-0.030 +0.60D 0.098 L Only -0.039-0.039 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.163 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.039 Ry, Top Max Ry, Top Min -0.039 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.297 5.663ftftinin 0.000 +D+0.750L 0.0000 0.223 5.663ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.297 5.663ftftinin 0.000 .Sketches 3.50 in1.50 in +Y +X 2x4 Load 1 Height = 11.250 ft0.150k Height = 11.250 ft0.150k 0.01klf 9 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C2 (Balloon framed stud @ Grid 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x6Analysis Method : 20.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 5.50 in Area 8.250 in^2 Ix 20.797 in^4 Iy 1.547 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 36.208 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 20.250 ft, D = 0.760 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.7719 Location of max.above base 10.057 ft Applied Axial 0.7962k Applied Mx 0.3588 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 19.330 psi 180.0Allowable Shear psi 0.07159 : 1 Bending Compression Shear Location of max.above base 20.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.07088 k Bottom along Y-Y 0.07088 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.8045 in at 10.193 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 367.110 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 20.250 ft0.272 ft0.2652X Axis +D+L 1.000 PASS PASS10.057 0.07159 20.250 ft0.247 ft0.7719X Axis +D+0.750L 1.250 PASS PASS10.057 0.04296 20.250 ft0.201 ft0.5556X Axis +0.60D 1.600 PASS PASS0.0 0.0 20.250 ft0.159 ft0.1536X Axis . 10 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C2 (Balloon framed stud @ Grid 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.796 +D+L -0.071 0.796-0.071 +D+0.750L -0.053 0.796-0.053 +0.60D 0.478 L Only -0.071-0.071 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.796 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.071 Ry, Top Max Ry, Top Min -0.071 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.804 10.193ftftinin 0.000 +D+0.750L 0.0000 0.603 10.193ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.804 10.193ftftinin 0.000 .Sketches 5.50 in1.50 in +Y +X 2x6 Load 1 Height = 20.250 ft0.760k Height = 20.250 ft0.760k 0.01klf 11 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 6x6Analysis Method : 20.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.1 Fb +1,200.0 1,200.0psi 1,000.0 625.0 170.0 825.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.0 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 132.764 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 20.250 ft, D = 0.760, E = 11.0 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.7696 Location of max.above base 0.0 ft Applied Axial 8.593k Applied Mx 0.0 k-ft Load Combination +D+0.70E Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 5.272 psi 170.0Allowable Shear psi 0.02067 : 1 Bending Compression Shear Location of max.above base 20.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.07088 k Bottom along Y-Y 0.07088 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp Only, fc/Fc' Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.2194 in at 10.193 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 369.087 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 20.250 ft0.386 ft0.08493X Axis +D+L 1.000 PASS PASS10.057 0.02067 20.250 ft0.353 ft0.1287X Axis +D+0.750L 1.250 PASS PASS0.1359 0.01240 20.250 ft0.289 ft0.08158X Axis +0.60D 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.04798X Axis +D+0.70E 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.7696X Axis +D+0.750L+0.5250E 1.600 PASS PASS0.1359 0.009691 20.250 ft0.231 ft0.5972X Axis +0.60D+0.70E 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.7376X Axis . 12 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.893 +D+L -0.071 0.893-0.071 +D+0.750L -0.053 0.893-0.053 +0.60D 0.536 +D+0.70E 8.593 +D+0.750L+0.5250E -0.053 6.668-0.053 +0.60D+0.70E 8.236 L Only -0.071-0.071 E Only 11.000 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 11.000 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.071 Ry, Top Max Ry, Top Min -0.071 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.219 10.193ftftinin 0.000 +D+0.750L 0.0000 0.165 10.193ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 +D+0.70E 0.0000 0.000 0.000ftftinin 0.000 +D+0.750L+0.5250E 0.0000 0.165 10.193ftftinin 0.000 +0.60D+0.70E 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.219 10.193ftftinin 0.000 E Only 0.0000 0.000 0.000ftftinin 0.000 . 13 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 5.50 in5.50 in +Y +X 6x6 Load 1 Height = 20.250 ft11.760k Height = 20.250 ft11.760k 0.01klf 14 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x4Analysis Method : 8Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 8 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 9.103 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 8.0 ft, D = 0.80, Lr = 0.060, L = 0.440 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.4305 Location of max.above base 3.973 ft Applied Axial 1.249k Applied Mx 0.0560 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 12.0 psi 180.0Allowable Shear psi 0.04444 : 1 Bending Compression Shear Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0280 k Bottom along Y-Y 0.0280 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-4 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.07605 in at 4.027 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 568.13 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 8.0 ft0.400 ft0.2756X Axis +D+L 1.000 PASS PASS3.973 0.04444 0.0 ft0.366 ft0.4305X Axis +D+Lr 1.250 PASS PASS0.0 0.0 8.0 ft0.301 ft0.2837X Axis +D+0.750Lr+0.750L 1.250 PASS PASS3.973 0.02667 0.0 ft0.301 ft0.3931X Axis +D+0.750L 1.150 PASS PASS3.973 0.02899 0.0 ft0.324 ft0.3818X Axis +0.60D 1.600 PASS PASS0.0 0.0 8.0 ft0.240 ft0.1551X Axis . 15 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.809 +D+L -0.028 1.249-0.028 +D+Lr 0.869 +D+0.750Lr+0.750L -0.021 1.184-0.021 +D+0.750L -0.021 1.139-0.021 +0.60D 0.485 Lr Only 0.060 L Only -0.028 0.440-0.028 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 1.249 Axial, Base Min 0.060 Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.028 Ry, Top Max Ry, Top Min -0.028 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.076 4.027ftftinin 0.000 +D+Lr 0.0000 0.000 0.000ftftinin 0.000 +D+0.750Lr+0.750L 0.0000 0.057 4.027ftftinin 0.000 +D+0.750L 0.0000 0.057 4.027ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 Lr Only 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.076 4.027ftftinin 0.000 . 16 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 3.50 in1.50 in +Y +X 2x4 Load 1 Height = 8.0 ft1.30k Height = 8.0 ft1.30k 0.01klf 17 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x6Analysis Method : 19.5Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 5.50 in Area 8.250 in^2 Ix 20.797 in^4 Iy 1.547 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 34.867 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 19.50 ft, D = 0.410, Lr = 0.060 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070, W = 0.0160 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.9240 Location of max.above base 9.685 ft Applied Axial 0.4899k Applied Mx 0.5917 k-ft Load Combination +D+0.750Lr+0.750L+0.450W Load Combination +D+0.750Lr+0.750L+0.450W Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 33.106 psi 288.0Allowable Shear psi 0.07663 : 1 Bending Compression Shear Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.1560 k Bottom along Y-Y 0.1560 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 1.581 in at 9.815 ft above base for load combination : W Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 377.001 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 19.50 ft0.272 ft0.1482X Axis +D+L 1.000 PASS PASS9.685 0.06894 0.0 ft0.247 ft0.5910X Axis +D+Lr 1.250 PASS PASS0.0 0.0 19.50 ft0.201 ft0.1643X Axis +D+0.750Lr+0.750L 1.250 PASS PASS9.815 0.04136 0.0 ft0.201 ft0.4277X Axis +D+0.750L 1.150 PASS PASS9.815 0.04496 0.0 ft0.217 ft0.4261X Axis +D+0.60W 1.600 PASS PASS9.685 0.05909 0.0 ft0.159 ft0.7026X Axis +D+0.750Lr+0.750L+0.450W1.600 PASS PASS9.685 0.07663 0.0 ft0.159 ft0.9240X Axis 18 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About +D+0.750L+0.450W 1.600 PASS PASS9.685 0.07663 0.0 ft0.159 ft0.9051X Axis +0.60D+0.60W 1.600 PASS PASS9.685 0.05909 0.0 ft0.159 ft0.6485X Axis +0.60D 1.600 PASS PASS0.0 0.0 19.50 ft0.159 ft0.08582X Axis .Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.445 +D+L -0.068 0.445-0.068 +D+Lr 0.505 +D+0.750Lr+0.750L -0.051 0.490-0.051 +D+0.750L -0.051 0.445-0.051 +D+0.60W -0.094 0.445-0.094 +D+0.750Lr+0.750L+0.450W -0.121 0.490-0.121 +D+0.750L+0.450W -0.121 0.445-0.121 +0.60D+0.60W -0.094 0.267-0.094 +0.60D 0.267 Lr Only 0.060 L Only -0.068-0.068 W Only -0.156-0.156 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.505 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.156 Ry, Top Max Ry, Top Min -0.156 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.692 9.815ftftinin 0.000 +D+Lr 0.0000 0.000 0.000ftftinin 0.000 +D+0.750Lr+0.750L 0.0000 0.519 9.815ftftinin 0.000 +D+0.750L 0.0000 0.519 9.815ftftinin 0.000 +D+0.60W 0.0000 0.949 9.815ftftinin 0.000 +D+0.750Lr+0.750L+0.450W 0.0000 1.230 9.815ftftinin 0.000 +D+0.750L+0.450W 0.0000 1.230 9.815ftftinin 0.000 +0.60D+0.60W 0.0000 0.949 9.815ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 Lr Only 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.692 9.815ftftinin 0.000 W Only 0.0000 1.581 9.815ftftinin 0.000 . 19 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 5.50 in1.50 in +Y +X 2x6 Load 1 Height = 19.50 ft0.470k Height = 19.50 ft0.470k 0.02klf 20 21 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 E−W L/B =0.56 Cp =0.8 (Windward) Fig.27.3−1 Cp =0.0 N/A (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =0.0 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =1.26 Cp =−1.30 (Windward)Fig.27.3−1 Cp =0.00 (Leeward)Fig.27.3−1 qGCp -qiGCi =−15.96 (Windward) qGCp -qiGCi =0.00 Mono slope (Leeward) qh GCp(x component) =−2.50 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 34 13.5 459 4,903 34 13.5 459 0 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 36 3 108 −270 36 3 108 0 Ptotal =4,634 lbs (lrfd) =2,780 lbs (asd) < Seismic = 6,423 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 23 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 N−S L/B =1.79 Cp =0.8 (Windward) Fig.27.3−1 Cp =−0.342 (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =−5.8 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =0.84 Cp =0.00 N/A (Windward)Fig.27.3−1 Cp =0.00 N/A (Leeward)Fig.27.3−1 qGCp -qiGCi =0.00 (Windward) qGCp -qiGCi =0.00 (Leeward) qh GCp(x component) =0.00 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 19 15 285 3,044 19 15 285 −1,666 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 23 3 69 0 23 3 69 0 Ptotal =4,711 lbs (lrfd) =2,826 lbs (asd) < Seismic = 6,423 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 24 2022 CBC Seismic Criteria (based on the requirements of ASCE 7−16) 2022 CBC Section 1613 Earthquake Loads  Site Parameters: Site Class:DDefault Latitude =35.291 deg N Google Earth Longitude =120.657 deg W Google Earth Seismic Design Category:D USGS Design Maps SS =1.074 g USGS Design Maps Fa =1.20 Section 11.4.4 SMS =Fa SS =1.289 g (16−20) SDS =2/3 x SMS =0.859 g (16−22) SDS,MAX =2/3 x SMS,MAX =N/A g Calcs Pg. , Based on Section 12.8.1.3 S1 =0.396 g USGS Design Maps Fv =1.904 Table 1613.2.3(2) SM1 =Fv S1 =0.754 g (16−21) SD1 =2/3 x SM1 =0.503 g (16−23) ASCE 7−16 Section 12.8 Equivalent Lateral Force Procedure  Structural Parameters: hn =19.0 ft Ct =0.020 Table 12.8−2 x =0.75 " Ta =Ct(hn)x =0.18 sec (12.8−7) TL =8 sec > Ta Figure 22−14 R =6.50 Table 12.2−1 Ie =1.00 Table 1.5−2  Seismic Coefficient: Cs =SDS / (R/Ie)(12.8−2) =0.13 Cs,max =SD1 / [T x (R/Ie)]for T < TL (12.8−3) =0.42 Cs,min =0.044SDSIe > 0.01 (12.8−5) 0.04 Cs,min =0.5S1 / (R/Ie)for S1 > 0.6g (12.8−6) =0.03 light framed construction with plywd shear panels PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 25 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES  Seismic Base Shear: V =Cs W (12.8−1) =0.13 W =0.17 W =0.09 W =0.120 W Strength Level with Rho = 1.3 ASD Level ASD Level with Rho = 1.3 Strength Level ASCE 7−16 Section 12.8 26 Seismic Weights − 2−Story Portion (52X−74X) Second Floor Framing Height 8 ft +/− Roof Level Framing Height 17 ft +/− Roof Level Roof. . . w =18 psf A =725 sf W =13,050 lb Exterior Walls. . . w =18 psf L =68 ft htrib =5.0 ft W =6,120 lb Interior Walls. . . w =10 psf L =48 ft htrib =5.0 ft W =2,400 lb Total Sesimic Weight at Roof 21,570 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 27 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES Floor Level Typical Floor . . . w =17 psf A =538 sf W =9,146 lb Exterior Walls. . . walls above = 6120 lb w =18 psf L =68 ft htrib =10.0 ft W =18,360 lb Interior Walls. . . walls above = 2400 lb w =10 psf L =48.0 ft htrib =4.0 ft W =4,320 lb Total Sesimic Weight at Floor 31,826 lb Vertical Distribution Two Story Portion ~ ASD Level, Rho = 1.3 Level Seismic W V Height VxH % V Per SF Roof 21,570 2595 17 44108.4 59.0 3791 5.2 2nd floor 31,826 3828 8 30626.3 41.0 2632 4.9 6423 74735 6423 Total Base Shear V =7058 lb V =6423 lb LRFD ASD Level with Rho = 1.3 28 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES E−W Line Loads Roof Floor Line 0X. . .Line 0X. . . A trib. =265 ft2 A trib. =209 ft2 V dia. =1,383 lb V dia. =1,023 lb V in plane SW =391 lb V in plane SW =329 lb V roof =1,774 lb V total =1,774 lb V total =3,125 lb Line 22X. . .Line 22X. . . A trib. =363 ft2 A trib. =269 ft2 V dia. =1,895 lb V dia. =1,316 lb V in plane SW =195 lb V in plane SW =175 lb V roof =2,090 lb V total =2,090 lb V total =3,582 lb Line 34X. . .Line 34X. . . A trib. =98 ft2 A trib. =60 ft2 V dia. =512 lb V dia. =294 lb V in plane SW =195 lb V in plane SW =173 lb V roof =707 lb V total =707 lb V total =1,174 lb A total =725 ft2 A total =538 ft2 N−S Line Loads Roof Floor Line 0Y. . .Line 0Y. . . A trib. =265 ft2 A trib. =209 ft2 V dia. =1,383 lb V dia. =1,023 lb V in plane SW =524 lb V in plane SW =381 lb V roof =1,907 lb V total =1,907 lb V total =3,311 lb Line 9Y. . .Line 9Y. . . A trib. =98 ft2 A trib. =60 ft2 V dia. =512 lb V dia. =294 lb V in plane SW =247 lb V in plane SW =208 lb V roof =759 lb V total =759 lb V total =1,261 lb Line 19Y. . .Line 19Y. . . A trib. =363 ft2 A trib. =269 ft2 V dia. =1,895 lb V dia. =1,316 lb V in plane SW =589 lb V in plane SW =589 lb V roof =2,484 lb V total =2,484 lb V total =4,389 lb A total =725 ft2 A total =538 ft2 29 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)ωdl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0X 1,774 S 11.00 10.0 161 1 19.00 17,738 192 16,630 60 MST60 22X SEE 1ST FLOOR SW 34X 707 S 10.00 10.0 71 1 10.00 7,073 234 5,613 154 MST60 0X 3,125 S 5.50 8.0 568 4 2.75 12,502 263 477 5,404 HDUE7 H/W ratio penalized S8.05684 2.75 12,502 263 477 5,404 HDUE7 H/W ratio penalized 22X 3,582 S 9.00 19.3 398 2 9.00 68,948 401 7,781 7,196 HDUE9−4x H/W ratio penalized 34X 1,174 S 10.00 8.0 117 1 10.00 9,392 246 5,900 521 HDUE3 Project: ______________________________________________________ V (lbs) E−W 2nd FLOOR E−W 1st FLOOR 30 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)ωdl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0Y 1,907 S 22.00 11.0 87 1 22.00 20,977 405 47,017 N/A MST60 9Y 759 S 12.00 9.5 63 1 12.00 7,213 252 8,704 N/A MST60 19Y 2,484 S 22.00 8.0 113 1 34.00 19,875 288 79,855 N/A MST60 0Y 3,311 S 22.00 8.0 150 1 22.00 26,484 155 18,039 393 HDUE3 15Y 1,261 S 12.00 8.0 105 1 12.00 10,085 155 5,367 410 HDUE3 19Y 4,389 S 27.00 9.0 163 1 34.00 39,504 173 48,076 N/A #N/A Project: ______________________________________________________ V (lbs) N−S 2nd FLOOR N−S 1st FLOOR 31 SHEAR WALL SCHEDULE ALLOWABLE VALUESShear WallSubfloor Connection (2 story or more)Concrete ConnectionPlywood 1/Nailing (10d's)VallSill Size FastenerVallSill Size FastenerVallSDS @ 8" o.c. 456 SW1one side 6" o.c. 339 SW1 2x 16d's @ 6" o.c. 374 SW1 2x 5/8" AB @ 4'-0" o.c. 372 SW1one side 4" o.c. 510 SW2 3x SDS @ 6" o.c.608 SW23x 5/8" AB @ 2'-8" o.c. 707 SW2one side 3" o.c.664 SW33x SDS @ 4" o.c. 912 SW3 3x 5/8" AB @ 2'-8" o.c. 707 SW3one side 2" o.c.869 SW43x SDS @3" o.c. 1216 SW4 3x 5/8" AB @ 1'-4" o.c. 1415 SW4Top Pl. Shear Clip ConnectionVallA35 @ 24" o.c.325 SW1A35 @ 12" o.c. 650 SW2A35 @ 8" o.c. 975 SW3A35 @ 6" o.c. 1300 SW4Shear Wall CapacityNOTES:Vall6" o.c.325SW11. Shear wall allowables based on NDS Table 4.3A4" o.c.510SW23" o.c.664SW32. Subfloor nailed connection allowables based on NDS Table 11N2" o.c.869SW4 2x sill, 16d's - Z = 1.6x118=188# ea.3. Subfloor SDS connection is Simpson SDS 1/4" dia.x 6" screws w/allowables per SimpsonSDS 1/4"x6"=190# x 1.6 = 304# ea.Holdowns4. Subfloor lag screw allowables based on NDS Table 11.5 for 3x sillMin.1/2" dia x 8" = 1.6x390=620# ea.Type Uplift Cap. ChordHDUE3 37902-2x5. Concrete connection allowables based on NDS Table 11EHDUE5 53752-2x2x sill, 5/8" dia. Bolts - Z = 1.6x930=1488# ea.HDUE766752-2x3x sill, 5/8" dia. Bolts - Z = 1.6x1180=1888# ea.HDUE9 84254x43x sill, 3/4" dia. Bolts - Z = 1.66x1540=2464# ea.6. Top Pl. shear clip connection is Simpson A35 w/allowables per SimpsonA35=650# ea.7. Holdown allowables per Simpson current catalog32 E-W Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 19.0 1.16 ok VDIA. - LINE 22X =1,895 lbs vdia. = 1,895 lbs /19.0 ft = 99.8 plf →214.3 plf D/C =0.5 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 10.0 2.20 ok VDIA. - LINE 22X =1,316 lb vdia. = 1,316 lbs /10.0 ft = 131.6 plf →214.3 plf D/C =0.6 (NDS Table 4.2C) N-S Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 19 22.0 0.86 ok VDIA. - LINE 19Y =1,895 lbs vdia. = 1,895 lbs /22.0 ft = 86.2 plf →214.3 plf D/C =0.4 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 19 14.5 1.31 ok VDIA. - LINE 19Y =1,316 lb vdia. = 1,316 lbs /14.5 ft = 90.8 plf →214.3 plf D/C =0.4 (NDS Table 4.2C) 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 33 Dia. chord design: line Vdia.(ASD)q = Vdia./L L D chord force Connector Connection Cap. D/C lb plf ft ft lbs MIN.lbs 0Y/19Y Roof 3,791 172 22 19 549 12−16d 2,447 0.22 0Y/19Y Floor 2,632 120 22 10 724 12−16d 2,447 0.30 Chord Force =qL2/D top pl. splice 12−16d 2,447 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 34 Collector Analysis (ASCE 12.10.2) Roof… Line 22X 1.25V = 2,369 lbs Ltotal =19.0 ft Lshearwall =9.0 ft v1 = V / L total =124.70 plf v2 = V / Lshearwall =263.25 plf v1 -v2 =-138.55 plf SW Distance Length (ft) 9.0 10.0 unit shear (plf -138.55 124.70 Drag load(lbs)0 -1247 0 Max. Drag Load =1247 lb (See above) 12 - 16d 2447 lb (calc. pg. ) D/C =0.51 Simp. CS16 1705 lb (Simp. Catalog ) D/C =0.73 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 35 Floor… Line 22X 1.25V = 1,645 lbs Ltotal =19.0 ft Lshearwall =9.0 ft v1 = V / L total =86.58 plf v2 = V / Lshearwall =182.79 plf v1 -v2 =-96.20 plf SW Distance Length (ft) 9.0 10.0 unit shear (plf -96.20 86.58 Drag load(lbs)0 -866 0 Max. Drag Load =866 lb (See above) 12 - 16d 2447 lb (calc. pg. )D/C =0.35 Simp. CS16 1705 lb (Simp. Catalog ) D/C =0.51 36 Nail Connection Structural Element: Nail : Species: Adjustment Factors: CM =1.00 CΔ =1.00 CD =1.60 Ct =1.00 Ceg =1.00 Cg =0.98 Cdi =1.00 Ctn =1.00 Z =131 lb (10 dia. min. pentration reduction included) m(1-m 2n)1+REA 1-m n =12 nails D =0.162 in s =1.5 in Es =1,600,000 psi Em =1,600,000 psi NDS Table 4A As =8.25 in2 Am =8.25 in2 EsAs EmAm EmAm EsAs γ = (180,000)(D 1.5)=11,737 lb/in u =1+γs/2 x (1/EmAm+1/EsAs)=1.00 m =u-(u2-1)1/2 =0.95 =0.98 Shear Plate Adjusted Design Value: Z’ =Z x CDCMCtCgCΔCegCdiCtn NDS Table 10.3.1 = 204 lb/ea. Z’ (12−16d) =2,447 lb Top plates splice 12 − 16d DF No. 2 Cg = NDS (10.3−1)n[(1+REAmn)(1+m)-1+m2n] REA =lessor of or =1.0 x PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 37 Foundation Design Allowable soil bearing pressure =1500 psf (CBC Table 1806.2) Footing Width W =15 in Footing Depth D=21 in Gridline 0Y /19Y (D+0.75Lr+0.75L) Roof DL =207 plf 207 plf Roof Lr =230 plf 173 plf Floor DL =11 plf 11 plf Floor LL =27 plf 20 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =835 plf 771 plf Soil bearing = 668 psf (Ptotal / W) <1500 psf Gridline 0X/34X (D+0.75Lr+0.75L) Roof DL =54 plf 54 plf Roof Lr =60 plf 45 plf Floor DL =106 plf 106 plf Floor LL =250 plf 188 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =830 plf 753 plf Soil bearing = 664 psf (Ptotal / W) <1500 psf Gridline 22X (D+0.75Lr+0.75L) Roof DL =54 plf 54 plf Roof Lr =60 plf 45 plf Floor DL =187 plf 187 plf Floor LL =440 plf 330 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =1,101 plf 976 plf Soil bearing = 881 psf (Ptotal / W) <1500 psf PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 38 Construction and Demolition Recycling and Waste Plan Please read this form carefully. The goal is to clearly document and create a plan to recycle a minimum of 65% of construction and demolition materials for permits after January 1, 2017, per Title 24 Chapter 11 of the Green Building Code. This form must be filled out in its entirety. For questions, email RecycleRight@slocity.org or call (805) 781-7215. Step 1: Complete Recycling Form Project Type * Residential Commercial Project Category * Demolition New Construction Addition Remodel/Tenant Improvement Project Site Address * 619 Grove Street, San Luis Obispo, CA 93401 Project Description * THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2- STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. Estimated Project Cost * $168,000.00 New Conditioned Square Footage * 920 Estimated Fine for Failure to Comply * 2% of total Estimated Project Cost $3,360.00 Property Owner Name * John Rourke Property Owner Email Address * Project Contact Name If different than property owner Chris Allen Project Contact Email Address If different than property owner Type of Material to be Generated (check all that apply)* Mixed C&D Concrete/Asphalt Dirt Cardboard Metals Wood Other Once all Materials are checked, please enter weight estimates for each of these categories below. Estimated Quantity of Generated Materials (in tons) Concrete/Asphalt Estimate * .5 Dirt Estimate * .5 Wood Estimate * .5 Note: a tonnage estimate guide can be found on the City 's Construction and Demolition webpage. If you plan to reuse or donate materials, please explain here. How will you transport the materials?* Self-Haul Roll-Off Company Which IWMA-certified roll-off company will you be using?* API Roll-Off Services Note: a list of IWMA-certified haulers, landfills, and transfer stations can be found on the City's Construction and Demolition webpage. ALL TONNAGE LEAVING PROJECT SITE MUST BE ACCOUNTED FOR ON THIS FORM AND FAILURE TO RECYCLE AT LEAST 65% OF MATERIALS MAY RESULT IN A PENALTY OF 2% OF PROJECT VALUATION I understand that I must produce receipts listing tonnage of all materials leaving the project site, regardless of destination or method of removal. I certify that I will communicate this plan and requirements to all contractors and other personnel who may be involved in disposal of materials from this project and inform them that they must provide receipts listing the tonnage for all recycling and trash disposal. The final permit and all waste receipts must be presented prior to final sign off. I understand that failure to do so may incur a penalty of 2% of total project valuation and the City of San Luis Obispo makes the final determination of project cost and fine for failure to comply. Signature * Print Name * Chris Allen Date * 2025-12-22 Step 2: Upon Completion of Project 1.  Gather receipts listing tonnage for all materials that left the project site or a roll-off diversion report from one of the listed IWMA-certified haulers. *Please note - receipts must list tonnage as recycled or disposed. Mixed recycling receipts qualify as 70% recycling and 30% trash.  2. Email all receipts to RecycleRight@slocity.org for approval before final inspection. Include permit number, receipts/diversion report, photos of donated items (if applicable). Please allow 1-3 business days for review. 3. If approved, you will receive an email confirmation. Questions? RecycleRight@slocity.org or (805) 781-7215 BUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC – www.energysoft.com. Grove Street ADU 2238 Bayview Heights Drive, Suite E , Carstairs Energy Inc. Timothy Carstairs, CEA, HERS, GPR San Luis Obispo, CA 93401 12/16/2025 25-121617 Los Osos, CA 93402 805-904-9048 619 Grove Street TABLE OF CONTENTS 3 1 20 Form MF1R Mandatory Measures Summary Table of Contents 2 Room Load Summary Form RMS-1 Residential Measures Summary 14 Form CF1R-PRF-01-E Certificate of Compliance Cover Page 15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 GENERAL INFORMATION 01 Project Name Grove Street ADU 02 Run Title Title 24 Analysis 03 Project Location 619 Grove Street 04 City San Luis Obispo 05 Standards Version 2022 06 Zip code 93401 07 Software Version EnergyPro 9.4 08 Climate Zone 5 09 Front Orientation (deg/ Cardinal)180 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)920 19 Glazing Percentage (%)13.15% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type All electric 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 35 29 49.6 Proposed Design 32.3 23 46.3 2.7 6 3.3 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 0.00 kWdc •PV System(s) removed due to Reduced PV Requirement of 0 kWdc 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr)Margin (EDR1)Margin (EDR2) Space Heating 2.53 17.21 2.54 20.58 -0.01 -3.37 Space Cooling 0.03 1.46 0.02 0.98 0.01 0.48 IAQ Ventilation 0.47 5.11 0.47 5.11 0 0 Water Heating 3.28 36.02 1.97 20.91 1.31 15.11 Self Utilization/Flexibility Credit 0 0 0 0 Efficiency Compliance Total 6.31 59.8 5 47.58 1.31 12.22 Photovoltaics 0 0 0 0 Battery 0 0 Flexibility 0 Indoor Lighting 0.88 9.4 0.88 9.4 Appl. & Cooking 4.29 53.67 4.26 53.33 Plug Loads 5.92 63.49 5.92 63.49 Outdoor Lighting 0.2 1.97 0.2 1.97 TOTAL COMPLIANCE 17.6 188.33 16.26 175.77 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 23.16 21.41 1.75 7.56 Net EUI2 23.16 21.41 1.75 7.56 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 0 No PV - required PV less than 1.8kWdc Standard (14-17%)Fixed none true n/a n/a n/a n/a n/a REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV exception 2: No PV required when minimum PV size (Section 150.1(c)14) < 1.8 kWdc (0 kW) •Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed •One or more heat pump water heaters have been modeled as demand response compatible 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Indoor air quality ventilation •Kitchen range hood •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Airflow in habitable rooms (SC3.1.4.1.7) •Verified HSPF •Verified heat pump rated heating capacity •Wall-mounted thermostat in zones greater than 150 ft2 (SC3.4.5) •Ductless indoor units located entirely in conditioned space (SC3.1.4.1.8) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Grove Street ADU 920 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Area Conditioned HVAC System1 920 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front Wall Living Area R21 Wall 180 Front 152 46 90 Left Wall Living Area R21 Wall 270 Left 272 23.5 90 Rear Wall Living Area R21 Wall 0 Back 152 0 90 Right Wall Living Area R21 Wall 90 Right 272 0 90 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front Wall 2 Living Area R21 Wall 180 Front 152 32 90 Left Wall 2 Living Area R21 Wall 270 Left 272 39.5 90 Rear Wall 2 Living Area R21 Wall 0 Back 152 0 90 Right Wall 2 Living Area R21 Wall 90 Right 272 0 90 Roof Living Area R-30 Roof Attic n/a n/a 60 n/a n/a Roof 2 Living Area R-30 Roof Attic n/a n/a 430 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Area Attic RoofLiving Area Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window B Window Front Wall Front 180 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window D Window Front Wall Front 180 1 10 0.3 NFRC 0.35 NFRC Bug Screen Window C Window Left Wall Left 270 1 7.5 0.3 NFRC 0.35 NFRC Bug Screen Window A Window Left Wall Left 270 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window A 2 Window Front Wall 2 Front 180 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window A 3 Window Front Wall 2 Front 180 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window A 4 Window Left Wall 2 Left 270 1 16 0.3 NFRC 0.35 NFRC Bug Screen 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window C 2 Window Left Wall 2 Left 270 1 7.5 0.3 NFRC 0.35 NFRC Bug Screen Window A 5 Window Left Wall 2 Left 270 1 16 0.3 NFRC 0.35 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door 1 Front Wall 20 0.5 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab Living Area 490 106 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Attic RoofLiving Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-30 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Not Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 50 Rheem XE50T10H22U0 (50 gal, JA13)Outside Living Area Living Area 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name HVAC System1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 n/a n/a HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 VCHP-ductless 1 HSPF 9.5 12500 10000 EERSEER 16 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Required Required Yes Yes Yes Yes 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Name Certified Low-Static VCHP System Airflow to Habitable Rooms Ductless Units in Conditioned Space Wall Mount Thermostat Air Filter Sizing &amp; Pressure Drop Rating Low Leakage Ducts in Conditioned Space Minimum Airflow per RA3.3 and SC3.3.3.4.1 Certified non-continuous Fan Indoor Fan not Running Continuously Heat Pump System 1 Not required Required Required Required Not required Not required Not required Not required Not required INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 56 0.35 Exhaust No n/a / n/a No Yes 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Timothy Carstairs Carstairs Energy Inc.12/22/2025 2238 Bayview Heights Dr STE E CEA 2022 Los Osos, CA 93402 8059049048 CHRISTOPHER ALLEN CWA Studios 12/22/2025 1668 Sydney Street C35818 San Luis Obispo, CA 93401 8052865186 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type  Single Family  Addition Alone Date  Multi Family  Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status New Page 14 of 20 12/16/2025 13.2% New Grove Street ADU none n/a 121 n/a CA Climate Zone 05 63.0 1 Heat Pump Perim = 106' New 1 New 4 HVAC System Ductless / with Fan Slab Opaque Door Roof - no insulation - Wood Framed Attic R 30 New 0.300 0.35 920 40 N/A 3.10 New - no insulation - Ductless 16.0 SEER 20 1,555 none none 1 none Electric Heat Pump Standard Left (W) Front (S)58.0 n/a New 490 New Door Wall Wood Framed 619 Grove Street San Luis Obispo N/A 9.50 HSPF 0.30 Split Heat Pump User Number: 6249 0.300 0.35 Setback New ID: 25-121617 R 21 Unheated Slab-on-Grade EnergyPro 9.4 by EnergySoft 490 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Building Envelope: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. * § 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. * § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, gasketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services (BHGS). § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R. § 110.8(j): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. § 150.0(a): Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. * § 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value. § 150.0(c): Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B. * § 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. * § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(g)1: Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to §150.0(d). § 150.0(g)2: Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. § 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. * Fireplaces, Decorative Gas Appliances, and Gas Log: § 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)1: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device. * § 150.0(e)3: Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control. * Space Conditioning, Water Heating, and Plumbing System: § 110.0-§ 110.3: Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the California Energy Commission. * § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N. * § 110.2(b): Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. * § 110.2(c): Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. * § 110.3(c)3: Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank surface heat loss rating. § 110.3(c)6: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters. * § 150.0(h)1: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. § 150.0(h)3B: Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer’s instructions. § 150.0(j)1: Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in § 609.11 of the California Plumbing Code. * § 150.0(j)2: Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment` maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. § 150.0(n)1: Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must designate a space at least 2.5’ x 2.5’ x 7’ suitable for the future installation of a heat pump water heater, and meet electrical and plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no more than 2” higher than the base of the water heater § 150.0(n)3: Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts and Fans: § 110.8(d)3: Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. § 150.0(m)1: CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼”, If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts; ducts installed in these spaces must not be compressed. * § 150.0(m)2: Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. § 150.0(m)9: Protection of Insulation. Insulation must be protected from damage due tosunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. § 150.0(m)11: Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. § 150.0(m)12: Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter. * 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(m)13: Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ≥ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air handlers and ≤ 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3. * Ventilation and Indoor Air Quality: § 150.0(o)1: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * § 150.0(o)1B: Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with §150.0(o)1C. § 150.0(o)1C: Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . Single-family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. § 150.0(o)1G: Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per §150.0(o)1Gvi. * § 150.0(o)1H&I: Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per § 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by §150.0(o)1C. § 150.0(o)2: Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1G Pool and Spa Systems and Equipment: § 110.4(a): Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating. * § 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * Lighting: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9. * § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen closets with an efficacy of at least 45 lumens per watt. § 150.0(k)1B: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. § 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1E: Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. § 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k). * 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1I: Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems. * § 150.0(k)2A: Accessible Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned on and off. * § 150.0(k)2B: Multiple Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed to comply with § 150.0(k). § 150.0(k)2C: Mandatory Requirements. Lighting controls must comply with the applicable requirements of § 110.9. § 150.0(k)2D: Energy Management Control Systems. An energy management control system (EMCS) may be used to comply with dimming, occupancy, and control requirements if it provides the functionality of the specified control per § 110.9 and the physical controls specified in § 150.0(k)2A. § 150.0(k)2E: Automatic Shutoff Controls. In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with opaque fronts or doors must have controls that turn the light off when the drawer or door is closed. § 150.0(k)2F: Dimmers. Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall-mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LED light sources in these spaces must comply with NEMA SSL 7A. § 150.0(k)2K: Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or shelves, lighting in display cabinets, and switched outlets must be controlled separately from ceiling-installed lighting. § 150.0(k)3A: Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic time switch control) or an astronomical time clock. An energy management control system that provides the specified control functionality and meets all applicable requirements may be used to meet these requirements. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must either comply with § 140.8 or consume no more than 5 watts of power. § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Solar Readiness: § 110.10(a)1: Single-family Residences. Single-family residences located in subdivisions with 10 or more single-family residences and where the application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b)-(e). §110.10(b)1A: Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. * § 110.10(b)2: Azimuth. All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment. * § 110.10(b)3B: Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the horizontal distance of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. * § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. § 110.10(c): Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family residences and central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b)-(c) must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. § 110.10(e)2: Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric.” Electric and Energy Storage Ready: 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(s) Energy Storage System (ESS) Ready. All single-family residences must meet all of the following: Either ESS-ready interconnection equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, or a dedicated raceway from the main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of 225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3’ of the main panelboard, with raceways installed between the panelboard and the switch location to allow the connection of backup power source. § 150.0(t) Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the furnace with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(u) Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(v) Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the dryer location with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” *Exceptions may apply. ROOM LOAD SUMMARY Project Name Date System Name Floor Area ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible PAGE TOTAL TOTAL * * Total includes ventilation load for zonal systems. 372 52 372 1 112 59 4,4941 7,938 112 Living Area 161 178 211 7,938 290 HVAC System 7,0153,444 290 211 113 161 12/16/2025 1st Floor 4,4484,494 Grove Street ADU 920 11,463 11,463 2nd Floor 59 3,444 52 Revised Dec. 2019 Design Professional’s stamp APPLICATION FOR WAIVER OF SOILS TEST FOR MINOR ADDITIONS TO ONE AND TWO-FAMILY DWELLING UNITS GENERAL INFORMATION: Project Address: ___________________________________Application #: _________________ Applicant Name: _____________________________________Phone #: ________________ BACKGROUND: Historically, quantifiable data has been created using accepted soil science methodologies by approved agencies using approved methods indicating that, in general, the soil conditions likely to be encountered throughout the City of San Luis Obispo would consist of expansive, compressible, shifting or other questionable soil characteristics. These types of soil conditions would require a complete geotechnical evaluation for moderate and major projects. PURPOSE: In order to help alleviate the burdens of time and disproportionately high cost associated with obtaining a soil test for minor residential additions up to 500 square feet to one and two family dwellings, the City of San Luis Obispo Building Division has developed a policy allowing a waiver of the soil test as specified in the California Residential Code Section R401.4. POLICY STATEMENT: Where a soils test has not been previously provided in accordance with the 2022 CRC Section R401.4; one and two family dwelling unit residential additions of 500 square feet or less, up to two stories (addition footprint area), may forego a soils test provided the applicant agrees to the following checked statements by signing and dating this application in the appropriate location at the bottom of this application: An on-site investigation has revealed no foundation failure of the existing residence. The type of construction proposed meets or exceeds the minimum provisions for wall and roof-ceiling construction in accordance with the 2022 CRC Chapters 6 and 8. The foundation system proposed meets or exceeds the minimum requirements in accordance with the 2019 City of San Luis Obispo Construction and Fire Code Amendments Table 1809.7. A minimum allowable soil bearing pressure of 1500 PSF has been utilized for the design of foundation systems as shown in the 2022 CRC Table R401.4.1. The proposed area of work on the site does not exceed a maximum 20% slope. Print Name:_____________________________________________________________ Licensed Architect or Engineer Signature: ____________________________________________Date: _____________ Office Use Only: Approval Signature: ___________________________________Date: ______________ 619 Grove Street, San Luis Obispo, CA 93405 Chris Allen 8052865186 Chris Allen 12/19/2025 Stormwater Control Plan for Post Construction Requirements Exhibit 4 Application Submittal Where directions state “Done” that means no additional information or forms below that point needs to be filled out or furnished. See Exhibits for Watershed Management Zones, Basins, & Urban Sustainability Areas Use “n/a” where information requested is not applicable. If you are unsure regarding how to fill out any of the information, please come in and request assistance from a staff person. Project Information Step 1 Applicant Name: Application No: Project Name: Location Address: Location APN: Site Zoning: Project Type:  Commercial Detached Single Family Residential Industrial Multi-unit Residential Mixed Use Public Project Phase: Project Description: Total Project Site Area = (a) Total New Impervious Surface Area = (b) Total Replaced Impervious Surface Area = (c) Total Existing Impervious Area = (d) Total Impervious Area of Completed Project = (e) Net Impervious Area: (a+b) – (c-d) = OR where (c-d) is a negative number: (a+b) = Your project is NOT subject to Post Construction Requirements if… Step 2  Area (a+b) of project is < 2,500 square feet – Done OR  Area (a+b) of project is > 2,500 square feet, and is a project type listed below ( type) – Done  Road & parking surface repair – slurry & fog & crack seal, pothole & spot patching, overlay & resurfacing & other damage repair with no expansion  Road & parking shoulder grading  Road & parking cleaning, repairing, maintaining, reshaping, regarding drainage systems  Sidewalk & bike path / lane project – no other impervious surface created and runoff is directed to vegetated area  Curb & gutter improvement or replacement – no other impervious created  Underground utility project – surface replaced in kind  Utility vaults – Ex: lift stations, backflows  Fuel storage – above ground with spill containment  Photovoltaic systems – on existing impervious surface, over pervious surface with vegetated cover, buffer strip at the most down gradient row of panels  Second story – no increase in building footprint  Decks & stairs & walkways – raised with space below for drainage  Temporary structures – in place less than 6 months  Trails and pathways, where no other impervious surfaces are replaced or created, and built to direct stormwater runoff to adjacent vegetated areas. Form revised: July 12, 2016 Chris Allen New attached ADU 619 grove Street, San Luis Obispo, CA 93405 001-056-052 R-1 New Construction This project consists of the construction of a new 2-story 920 S.F. attached accessory dwelling unit at the rear of an existing S.F.R. 3,589 S.F. 646 S.F. 230 S.F. 1,704 S.F. 2,350 S.F. 876 S.F. 4 (For Select Building Projects Less Than 1 Acre) PURPOSE: This plan can only be used for minor building projects (SFR - new, remodels, additions; and/or commercial remodels). Newly constructed commercial buildings under 2019 CalGreen Codes require the development and implementation of a WPCP similar to the standards of a State submitted SWPPP. This plan is only to serve as a guide, if the applicant elects to use it. The BMPS specified herein shall be considered just the “Minimum BMPs” and during the course of the project additional BMPs (Necessary BMPs) may be required to protect water quality. Please note that an in-fill new single family home project may require additional plan elements. This plan shall be used in accordance with CGP 2009-0009-DWQ, City Stormwater Permit & 2019 CalGreen Building Codes. GENERAL INFORMATION: WPCP Plan for Minor Building Projects) 1 of 4 Project Address: ________________________________________________________________________ Description of Work: ___________________________________________________________________ _____________________________________________________________________________________ Estimate total disturbed soil areas in square feet: __________ ** Erosion & Sediment Control Measures are required. Applicant’s Name: __________________________________ Applicant’s Tele No. (____) _____-_________ Emergency Contact: ______________________________ Tele: (___) ____-_____ Cell: (___) _____-______ Contractor’s Name: __________________________________ Contractor’s Tel No. (____) ____-_________ Contractor’s Mailing Address: ______________________________________________________________ (Street Address)(City)(State)(Zip) Type of Project - Check One Commercial / Industrial:  Alternations  New Con.  Site-work  Tenant Improvement  Other: __________________________________________________________________ Residential:  Additions  New Con.  Remodel  Other: _______________________ SCHEDULE: Anticipated Project Schedule (Calendar Days & Hours): Calendar days: __________________________________________________________________________ Hours: (From) ________________________________ (To) ______________________________________ BEST MANAGEMENT PRACTICES OR “BMPS” are procedures that help prevent pollutants from entering the City’s stormwater conveyance system and creeks. Indicate by checking ALL ANTICIPATED BMPS that must be incorporated into the project to ensure the protection of waterways and stormwater conveyance systems (i.e. gutters, streets, storm drain inlets, storm drains, catch basins, creeks, culverts and seasonal streams). Informational brochures on various project types and BMPs are available on the City website listed herein. For detailed information on the Best Management Practices listed herein refer to: Ca General Construction Permit Ca Green Building Codes Ca State Water Resources Control Board Ca Stormwater Quality Association* Caltrans Stormwater Pollution Templates Caltrans Supplement to Traffic Control Guide City of San Luis Obispo BMP Guides* City of San Luis Obispo Municipal Code City of SLO Stormwater Management Plan City of SLO Waterway Management - Plan I City of SLO Stream Management & - Plan II City of SLO Drainage Design Man. - Plan III City of SLO WPCP Guide* City Specifications Construction Industry Compliance Asst Center State Specifications - DOT http://www.waterboards.ca.gov/water_issues/programs/stormwater http://www.bsc.ca.gov/CALGreen/default.htm http://www.swrcb.ca.gov/water_issues/programs/stormwater http://www.casqa.org/ http://www.dot.ca.gov/hq/construc/stormwater/templates1.htm http://www.dot.ca.gov/hq/traffops/signtech/mutcdsupp https://bit.ly/3rWDzAa http://www.codepublishing.com/ca/sanluisobispo/ https://bit.ly/3sIS3m9 https://bit.ly/3oX9vlR https://bit.ly/3sJBE0V https://bit.ly/3uWmice https://bit.ly/3GYMpRY https://bit.ly/3t8NNOc http://www.cicacenter.org/swt/swt2.cfm?st=CA http://www.dot.ca.gov/hq/esc/oe/standards.php  Proximity to Storm Drains, Creeks & Known Underground Springs or Seeps: If the project site is within close proximity (< 150’) to a creek, storm drain inlet down gradient of the site and/or includes underground springs or seeps on site, the site plan may need to include the locations of each and additional specific BMPs may be required throughout the course of the project. Please consult with a Qualified Professional and/or Building Staff for guidance. Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 619 Grove Street, San Luis Obispo, CA 93405 of an existing single family residence. This project consists of the construction of a new 2-story 920 SF attached accessory dwelling unit at the rear 490 John Rourke 805 440 Chris Allen 286 5186 Monday through Friday 7 am 5 pm 80 4973 WPCP Plan for Minor Building Projects 2 of 4 ANTICIPATED BMPS NOTE: A “” indicates mandatory BMPs for all projects. Good Housekeeping: Keep site clean & organized at all times.  Pre-inventory BMPs: Develop a list all materials to be used on site to determine proper storage to avoid exposure to the elements as appropriate.  Material stockpile BMPs  Chemical storage BMPs  Inclement weather – materials storage BMPs  Impervious surface sweeping BMPs  Spill management & reporting BMPs. Waste Management Plan: All waste products must be containerized & covered at all times.  Waste management BMPs  Concrete, paint, plaster residue BMPs (lined washout pit, cover during rain events)  Hazardous spill management BMPs  Landscape materials BMPs  Potential pollutant source list: Detailed list of chemicals, solvents, paints & fertilizers to be used on the site.  Painting BMPs (lined washout pit, cover daily)  Completed City C&D Plan  Portable toilet BMPs  Equipment / vehicle BMPs Erosion Control Measures - to prevent sediment from becoming dislodged due to rain & wind event.  Riparian protection BMPs  Temporary soil stabilization BMPs  Temporary curb access BMPs  Vegetation preservation BMPs  Slope stabilization BMPs  Wind erosion BMPs  Dust control BMPs  Permanent soil stabilization BMPs  Phased construction BMPs  Steep slope BMPs  Post storm erosion control BMPs Sediment Control Measures – to control & detain dislodged sediment from leaving the site.  Creek protection BMPs  Site perimeter BMPs  Sediment basin BMPs  Stabilized construction exit(s) / entrance(s)  Storm drain inlet protection BMPs  Waterway & stabilized drainage way BMPs  Rapid soil stabilization BMPs  Advanced settling devices  Post storm event sediment control BMPs Run-on & Run-off Control Measures: Overland flow of storm water both on and off-site must be effectively managed.  Stormwater run-on BMPs  Stormwater run-off BMPs Non-Stormwater Management: For work performed in the street, or to temporarily store materials in the street or on the sidewalk you must secure an encroachment permit.  Equipment tool washout BMPs  Encroachment permits  Potential non-stormwater discharge BMPs  Saw-cutting BMPs  Scheduling BMPs Site Schematic: To reflect the location of all BMPs to be used on site. For example, depict the location of all perimeter control measures, such as silt fencing or straw wattles on a schematic.  For all construction projects with outside activities. Water Efficient Landscape Plans Submittal: For new construction sites a water efficient landscape plan may be required.  Refer to Utilities Conservation Post Construction Stormwater Devices  Pre & post stormwater run-off calculation  A post construction maintenance plan  A private stormwater conveyance system agreement, and  A post construction site schematic required Inspect, Maintain, Clean, Repair & Report – all site BMP’s on active and inactive construction sites weekly. Repairs must be made as necessary. Document all activities in a log.  Weekly inspection schedule  Pre & post storm event inspections  BMP cleaning schedule  BMP maintenance schedule  BMP repair protocol  Documentation & records management protocol  Reporting protocol Project Specific BMPs  _________________________________  _________________________________  _________________________________  _________________________________  _________________________________  _________________________________ Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 WPCP Plan for Minor Building Projects 3 of 4 SITE SCHEMATIC Required for all projects that include grading activities include a reasonable sketch depicting where all required and necessary BMPs shall be placed on and off site. Be sure to include: a directional arrow, slope directions reflecting after grading is complete, scale used, the location of all structures on site, the location of all waterways on and / or abutting the site, location of closest storm drain inlet, frontage and side streets and wild lands. Note additional requirements (i.e. erosion and grading plans, post construction stormwater device elements) may be required, so please refer to City Building staff for direction. Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 WPCP Plan for Minor Building Projects 4 of 4 OFFICE USE ONLY: Received By: _______________ Date: __________ Approved By: _______________ Date: ____________ Denied: By: _______________ Date: __________ Comments: ___________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ PROJECT FEE: _____________ WPCP PLAN FOR BUILDING PROJECTS LESS THAN 1 ACRE The following sections of the City Municipal Code, City Standard Specifications, Storm Water Management Regulations, Green Building Codes and Fish & Game Regulations shall be reviewed by the permittee, and the permittee shall receive approval of this Minor WPCP prior to the commencement of work on the site. Plan BMPs shall be implemented on site at all times and verified for compliance. Permittee is required to maintain a log of all routine inspections, cleanings, maintenance and repairs made to all BMPs on site at all times for review by any representative of the City upon request. Failure to adhere to the WPCP, State and Federal Regulations may result in a Notice of Violation and/or an Administrative Citation and/or a Stop Work Order issued until the site is in conformance with the requirements of this plan. APPLICABLE SPECIFICATIONS: San Luis Obispo Municipal Code 8.04 Solid Waste Disposal Title 12 Streets, Sidewalks and Public Places 12.08 Urban Storm Water Quality Management and Discharge Control 12.23 Creek Protection Ordinance 13.08.130 Stormwater & unpolluted drainage 15.04.010 All disturbed surfaces 17.17.05 Neighborhood preservation City Specifications Section 3-1.03A, Encroachment Permit 4-1.07 Work Site Maintenance 6-1.03 Storage of Materials Section 7-1.01G Water Pollution Building Regulations J103.1 & J103.2 – Grading permits required City Specifications (Continued) Section 1010B, Uniform Design Criteria – Drainage and Erosion Control 19-1.07 Sawcutting 20.3 Erosion Control Storm Water Regulations Federal Water Pollution Control Act (CWA) California Construction Stormwater Permit California Porter Cologne Act of 2002 California Green Building Codes (Chp 4 & 5) City of SLO WPCP Guide City of SLO Construction BMP Guide Fish and Game Regulations: 1600, 1602, 5650, 5651 & 5652 I agree to follow the requirements as set forth in this Guide (WPCP), the City of San Luis Obispo’s Stormwater Management Plan, the State of California’s General Construction Permit, California Green Building Codes (Chapters 4 & 5) the Federal Clean Water Act and all applicable specifications. In addition, I understand and agree to the following: (1) Dynamic Plan: additional BMPs, both temporary and permanent may be required during the course of the project at the discretion of the City Inspector(s) in order to ensure the protection of local water quality, (2) it is permittee’s obligation to take additional corrective actions when required to protect local water quality, (3) failure to comply with all the requirements could cause the permit to be revoked; the issuance of a stop work order, a notice to comply, a notice of violation and/or a citation; (4) the doing of any work under this permit shall constitute an acceptance of the provisions of this permit and all attachments and documents referenced herein, (5) a copy of this signed approved Guide shall remain at the job site at all times available for review by any public official, and (6) overland flow storm water run-off & run-on has been adequately designed for & managed. Applicant: Permit #: Check One:  Owner  Contractor  Design Professional  Legal Representative Signature: Date: If you require assistance in completing this “Plan” please contact Notes: An * indicates a construction reference source specific to Stormwater BMPs. Please refer to the City’s website for “BMP Descriptions for Minor Building Projects” handout. Use of this template plan is at the discretion of City personnel. (805) 781-7180 Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 2019 2019 03/15/2022 12/19/2025 Chris Allen Hydraulic Calculation Check — 619 Grove Street, San Luis Obispo, CA (10-yr, 25-yr, 50-yr, 100-yr), Rational Method + 2" PVC Hydraulics Contributing Area = 1,041 sf; Runoff Composite Coefficient 𝐶𝐶= 0.55 1) Inputs / Assumptions Site / Hydrology • Contributing drainage area, 𝐴𝐴= 1,041 ft² • Runoff coefficient, 𝐶𝐶= 0.55 (Table 4-7) • Method: Rational Method (peak runoff rate) • Rainfall intensity source: SLO Creek Drainage Design Manual (Feb 2003), Table 4-6 (558–609 mm /hr annual rainfall band), 10-minute duration: o 10-year: 𝑖𝑖10 =91 mm/hr o 25-year: 𝑖𝑖25 =102 mm/hr o 50-year: 𝑖𝑖50 =117 mm/hr o 100-year: 𝑖𝑖50 =127 mm/hr Pump / Discharge • Pipe: 2" PVC (assume 2" Sch 40 ID ≈ 2.067 in) • Straight pipe length, 𝐿𝐿= 60 ft • Static head (lift), 𝐻𝐻𝑠𝑠= 0.6 ft • Friction equation: Hazen–Williams, PVC 𝐶𝐶𝐻𝐻𝐻𝐻=150(typical smooth PVC) • Minor loss: (1) 90° elbow, assume 𝐾𝐾= 0.9(typical value; varies by elbow radius/type) Design criterion • “satisfactory pump rate with rainfall totals” interpreted as: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝≥ 𝑄𝑄𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖, 𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝 (i.e., pump discharge rate at operating head must be at least peak runoff inflow rate) 2) Conversions 2.1 Area in acres 𝐴𝐴=104143560 = 0.02390 ac 2.2 Rainfall intensity conversion (mm/hr to in/hr) 𝑖𝑖(in/hr)=𝑖𝑖(mm/hr)25.4 𝑖𝑖10 =9125.4 = 3.583 in/hr;𝑖𝑖25 =10225.4 = 4.0157 in/hr; 𝑖𝑖50 =11725.4 = 4.6062 in/hr; 𝑖𝑖100 =12725.4 = 5.0 in/hr 3) Peak runoff inflow (Rational Method) Rational Method (US customary): 𝑄𝑄(cfs)= 1.008 𝐶𝐶𝑖𝑖�𝑖𝑖𝑖𝑖ℎ𝑟𝑟�𝐴𝐴(𝑎𝑎𝑎𝑎)𝐶𝐶a Convert to gpm: 𝑄𝑄(gpm) =𝑄𝑄(cfs) × 448.83 3.1 10-year peak inflow 𝑄𝑄10 = 1.008(0.55)(3.583)(0.0239)(1.0) = 0.04748 cfs 𝑄𝑄10 = 0.04748 × 448.83 =21.31 gpm 3.2 25-year peak inflow 𝑄𝑄25 = 1.008(0.55)(4.0157)(0.0239)(1.1) = 0.05853 cfs 𝑄𝑄25 = 0.05853 × 448.83 =26.27 gpm 3.3 50-year peak inflow 𝑄𝑄10 = 1.008(0.55)(4.6062)(0.0239) = 0.07324 cfs 𝑄𝑄10 = 0.07324 × 448.83 =32.87 gpm 3.4 100-year peak inflow 𝑄𝑄25 = 1.008(0.55)(5.0)(0.0239)(1.25) = 0.08281 cfs 𝑄𝑄25 = 0.08281 × 448.83 =37.17 gpm Minimum pump flow to “keep up” with peak runoff (hydrology requirement): • 10-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥21.31 gpm • 25-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥26.27 gpm • 50-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥32.87 gpm • 100-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥37.17 gpm Rainfall intensities source: SLO Creek Drainage Design Manual Table 4-5. 4) Hydraulic head requirement through 2" PVC (60 ft + 1 elbow) 4.1 Straight-pipe friction (Hazen–Williams; 60 ft) Hazen–Williams headloss (ft): ℎ𝑖𝑖=4.52 𝐿𝐿 𝑄𝑄1.85𝐶𝐶𝐻𝐻𝐻𝐻1.85  𝑑𝑑4.87 Where: • 𝐿𝐿=60 ft • 𝑄𝑄in gpm • 𝐶𝐶𝐻𝐻𝐻𝐻=150 • 𝑑𝑑=2.067 in Computed straight-pipe friction losses: • At 21.31 gpm: ℎ𝑖𝑖≈0.213 ft • At 26.27 gpm: ℎ𝑖𝑖≈0.314 ft • At 32.87 gpm: ℎ𝑖𝑖≈0.477 ft • At 37.17 gpm: ℎ𝑖𝑖≈0.595 ft 4.2 Elbow minor loss (1 elbow) Minor loss: ℎ𝑝𝑝=𝐾𝐾𝑣𝑣22𝑔𝑔 Using 𝐾𝐾=0.9, 𝑔𝑔=32.2 ft/s2 , 2" Sch 40 ID ≈ 2.067 in: • Velocity at 21.31 gpm: 𝑣𝑣≈2.04 ft/s ℎ𝑝𝑝,10 ≈0.058 ft • Velocity at 26.27 gpm: 𝑣𝑣 ≈2.51 ft/s ℎ𝑝𝑝,25 ≈0.088 ft • Velocity at 32.87 gpm: 𝑣𝑣 ≈3.14 ft/s ℎ𝑝𝑝,10 ≈0.137 ft • Velocity at 37.17 gpm: 𝑣𝑣 ≈3.55 ft/s ℎ𝑝𝑝,10 ≈0.175 ft 4.3 Total Dynamic Head (TDH) 𝑇𝑇𝑇𝑇𝐻𝐻=𝐻𝐻𝑠𝑠+ℎ𝑖𝑖+ℎ𝑝𝑝 with 𝐻𝐻𝑠𝑠= 0.6 ft • 10-yr TDH @ 21.31 gpm 𝑇𝑇𝑇𝑇𝐻𝐻10 = 0.6 + 0.213 + 0.058 = 0.871 ft • 25-yr TDH @ 26.27 gpm 𝑇𝑇𝑇𝑇𝐻𝐻25 = 0.6 + 0.314 + 0.088 = 1.002 ft • 50-yr TDH @ 32.87 gpm 𝑇𝑇𝑇𝑇𝐻𝐻50 = 0.6 + 0.477 + 0.137 = 1.214 ft • 100-yr TDH @ 37.17 gpm 𝑇𝑇𝑇𝑇𝐻𝐻100 = 0.6 + 0.595 + 0.175 = 1.37 ft 5) Minimum pump “size” stated as duty points (Flow @ Head) To keep up with peak runoff inflow: Design Storm Intensity basis (10- min) Antecedent Moisture Factor (Ca) Runoff coeff. 𝐶𝐶 Peak inflow 𝑄𝑄𝑖𝑖𝑖𝑖(gpm) Static head (ft) 60 ft 2" friction (ft) 1 elbow minor (ft) TDH (ft) Minimum pump duty point 10-year 91 mm/hr 1.0 0.55 21.31 0.6 0.213 0.058 0.871 ≥ 21.4 gpm @ ~0.9 ft TDH 25-year 102 mm/hr 1.1 0.55 26.27 0.6 0.314 0.088 1.002 ≥ 26.3 gpm @ ~1.1 ft TDH 50-year 117 mm/hr 1.2 0.55 32.87 0.6 0.477 0.137 1.214 ≥ 32.9 gpm @ ~1.3 ft TDH 100- year 127 mm/hr 1.25 0.55 37.17 0.6 0.595 0.175 1.37 ≥ 37.2 gpm @ ~1.4 ft TDH Rainfall intensity source: SLO Creek Drainage Design Manual Table 4-6 for City of SLO. 6) Notes / Limitations for engineering review 1. TDH includes only: 0.6 ft static lift + 60 ft straight 2" pipe + one elbow. Any additional fittings (check valve, reducer, discharge losses, etc.) will add head. 2. Rational Method peak runoff depends on selected duration (typically near time of concentration). This check uses 10-minute intensity as a conservative short-duration basis per Table 4-6 for City of SLO. Calculations Job #: SWA 25053.01 Date: 12/01/25 Contents Load Tables 1 Roof & Floor Framing 2-6 Wall Stud / Post Design 7-20 Lateral Design 21-37 Foundation Design 38 Structural Calculations For RESIDENTAIL ADDITION 619 Grove St. San Luis Obispo, CA 93401 Client: CWA Studios Stair Calculations for Plan Check 39-45 Load Tables: Roof Framing Roof Comp Shingles =6.00 psf 5/8" plywood sheathing =1.90 psf 2x12 @ 16" o.c. =3.10 psf Insulation =0.50 psf Gyp Ceiling =3.00 psf Subtotal = 14.50 psf Slope correction for 2:12 =1.01 Subtotal =14.7 psf misc (sprinklers, overframing etc.) =3.30 psf Total Roof DL = 18.0 psf Roof Lr =20.00 psf Floor Framing Flooring =5.00 psf 3/4" Plywd. =2.30 psf 2−2x10 @ 16" o.c. =3.40 psf gyp ceiling / Plaster =3.00 psf Misc. =3.30 psf Total Floor DL = 17.00 psf Floor LL =40.00 psf Exterior Walls Stucco / Stone Veneer =10.00 psf Plywood sheathing =1.50 psf 2x6 wood studs @ 16" o.c. =1.50 psf Insulation =0.50 psf 5/8" gypboard =3.00 psf Misc. =1.50 psf Total Exterior Wall DL = 18.00 psf 2x6 wood studs @ 16" o.c. =1.50 psf Insulation =0.50 psf 5/8" gypboard [two sides] =6.00 psf Misc. =2.00 psf Total Interior Wall DL = 10.00 psf Interior Walls PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 1 2 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: ROOFDescription : Wood Beam Design :RR1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.669 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 9.500 inft 38.69 psi Fb : Allowable : 1,293.75 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.172 : 1 0.000 ft 864.95 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.275 in Transient Upward 0.000in Total Downward 0.523 in Total Upward 0.000 in 0.23 0.250.23 0.25 Ratio 828 435Ratio LC: Lr Only LC: +D+Lr LC:LC: Wood Beam Design :RR2 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 2.0 ft .Design Summary Max fb/Fb Ratio =0.070 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 2.500 inft 10.58 psi Fb : Allowable : 1,293.75 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.047 : 1 4.067 ft 90.07 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.002 in Transient Upward 0.000in Total Downward 0.004 in Total Upward 0.000 in 0.09 0.100.09 0.10 Ratio 9999 9999Ratio LC: Lr Only LC: +D+Lr LC:LC: 3 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Wood Beam Design :RB1 - RIDGE BEAM Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 (1) Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 (1) Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 5.0 ft .Design Summary Max fb/Fb Ratio =0.494 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 6.000 inft 36.77 psi Fb : Allowable : 1,125.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.163 : 1 11.080 ft 555.89 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.071 in Transient Upward 0.000in Total Downward 0.134 in Total Upward 0.000 in 0.54 0.600.54 0.60 Ratio 2039 1073Ratio LC: Lr Only LC: +D+Lr LC:LC: 4 5 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: FLOORDescription : Wood Beam Design :FJ1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-22 / IBC 2024 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.755 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 7.375 inft 43.40 psi Fb : Allowable : 1,035.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.241 : 1 13.816 ft 781.91 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.200 in Transient Upward 0.000in Total Downward 0.285 in Total Upward 0.000 in 0.17 0.390.17 0.39 Ratio 884 620Ratio LC: L Only LC: +D+L LC:LC: Wood Beam Design :FB1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-22 / IBC 2024 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.032 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 2.250 inft 3.81 psi Fb : Allowable : 990.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.021 : 1 0.000 ft 31.19 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.001 in Transient Upward 0.000in Total Downward 0.001 in Total Upward 0.000 in 0.05 0.120.05 0.12 Ratio 9999 9999Ratio LC: L Only LC: +D+L LC:LC: 6 Wind Criteria ASCE 7−16 − Chapter 30 ASCE 7−16 Design Wind Loads [Component & Cladding]  Wind Design Force: P=qh (GCp -GCpi)(30.3−1) qh = 0.00256KzKztKdKeV2 26.10−1 Kz =0.66 (Exp. B) Sect 26.10.1 and Table 26.10−1 Kzt =1.00 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.00 mph Fig. 26.5−1B qz =12.4 psf (lrfd) At =10.0 ft2 min. GCp =1.0 (Zone 4 &5) Fig.30.3−1 GCp =−1.1 (Zone 4) Fig.30.3−1 GCp =−1.4 (Zone 5)Fig.30.3−1 GCpi =0.18 26.13 & Table 26.13−1 P= −15.90 psf (Zone 4) P= −19.63 psf (Zone 5) PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 7 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x4Analysis Method : 11.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0 psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 11.25 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 12.801 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 11.250 ft, D = 0.150 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.3541 Location of max.above base 5.587 ft Applied Axial 0.1628 k Applied Mx 0.1107 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 16.875 psi 180.0Allowable Shear psi 0.06250 : 1 Bending Compression Shear Location of max.above base 11.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.03938 k Bottom along Y-Y 0.03938 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.2974 in at 5.663 ft above base for load combination :+D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 305.488 psi Other Factors for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 11.250 ft0.217 ft0.1021X Axis +D+L 1.000 PASS PASS5.587 0.06250 11.250 ft0.197 ft0.3541X Axis +D+0.750L 1.250 PASS PASS5.587 0.03750 11.250 ft0.159 ft0.2326X Axis +0.60D 1.600 PASS PASS0.0 0.0 11.250 ft0.125 ft0.05973X Axis . 8 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k)Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.163 +D+L -0.039 0.163-0.039 +D+0.750L -0.030 0.163-0.030 +0.60D 0.098 L Only -0.039-0.039 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.163 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.039 Ry, Top Max Ry, Top Min -0.039 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.297 5.663ftftinin 0.000 +D+0.750L 0.0000 0.223 5.663ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.297 5.663ftftinin 0.000 .Sketches 3.50 in1.50 in +Y +X 2x4 Load 1 Height = 11.250 ft0.150k Height = 11.250 ft0.150k 0.01klf 9 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C2 (Balloon framed stud @ Grid 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x6Analysis Method : 20.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 5.50 in Area 8.250 in^2 Ix 20.797 in^4 Iy 1.547 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 36.208 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 20.250 ft, D = 0.760 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.7719 Location of max.above base 10.057 ft Applied Axial 0.7962k Applied Mx 0.3588 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 19.330 psi 180.0Allowable Shear psi 0.07159 : 1 Bending Compression Shear Location of max.above base 20.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.07088 k Bottom along Y-Y 0.07088 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.8045 in at 10.193 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 367.110 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 20.250 ft0.272 ft0.2652X Axis +D+L 1.000 PASS PASS10.057 0.07159 20.250 ft0.247 ft0.7719X Axis +D+0.750L 1.250 PASS PASS10.057 0.04296 20.250 ft0.201 ft0.5556X Axis +0.60D 1.600 PASS PASS0.0 0.0 20.250 ft0.159 ft0.1536X Axis . 10 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C2 (Balloon framed stud @ Grid 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.796 +D+L -0.071 0.796-0.071 +D+0.750L -0.053 0.796-0.053 +0.60D 0.478 L Only -0.071-0.071 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.796 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.071 Ry, Top Max Ry, Top Min -0.071 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.804 10.193ftftinin 0.000 +D+0.750L 0.0000 0.603 10.193ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.804 10.193ftftinin 0.000 .Sketches 5.50 in1.50 in +Y +X 2x6 Load 1 Height = 20.250 ft0.760k Height = 20.250 ft0.760k 0.01klf 11 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 6x6Analysis Method : 20.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.1 Fb +1,200.0 1,200.0psi 1,000.0 625.0 170.0 825.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.0 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 132.764 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 20.250 ft, D = 0.760, E = 11.0 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.7696 Location of max.above base 0.0 ft Applied Axial 8.593k Applied Mx 0.0 k-ft Load Combination +D+0.70E Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 5.272 psi 170.0Allowable Shear psi 0.02067 : 1 Bending Compression Shear Location of max.above base 20.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.07088 k Bottom along Y-Y 0.07088 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp Only, fc/Fc' Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.2194 in at 10.193 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 369.087 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 20.250 ft0.386 ft0.08493X Axis +D+L 1.000 PASS PASS10.057 0.02067 20.250 ft0.353 ft0.1287X Axis +D+0.750L 1.250 PASS PASS0.1359 0.01240 20.250 ft0.289 ft0.08158X Axis +0.60D 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.04798X Axis +D+0.70E 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.7696X Axis +D+0.750L+0.5250E 1.600 PASS PASS0.1359 0.009691 20.250 ft0.231 ft0.5972X Axis +0.60D+0.70E 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.7376X Axis . 12 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.893 +D+L -0.071 0.893-0.071 +D+0.750L -0.053 0.893-0.053 +0.60D 0.536 +D+0.70E 8.593 +D+0.750L+0.5250E -0.053 6.668-0.053 +0.60D+0.70E 8.236 L Only -0.071-0.071 E Only 11.000 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 11.000 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.071 Ry, Top Max Ry, Top Min -0.071 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.219 10.193ftftinin 0.000 +D+0.750L 0.0000 0.165 10.193ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 +D+0.70E 0.0000 0.000 0.000ftftinin 0.000 +D+0.750L+0.5250E 0.0000 0.165 10.193ftftinin 0.000 +0.60D+0.70E 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.219 10.193ftftinin 0.000 E Only 0.0000 0.000 0.000ftftinin 0.000 . 13 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 5.50 in5.50 in +Y +X 6x6 Load 1 Height = 20.250 ft11.760k Height = 20.250 ft11.760k 0.01klf 14 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x4Analysis Method : 8Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 8 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 9.103 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 8.0 ft, D = 0.80, Lr = 0.060, L = 0.440 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.4305 Location of max.above base 3.973 ft Applied Axial 1.249k Applied Mx 0.0560 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 12.0 psi 180.0Allowable Shear psi 0.04444 : 1 Bending Compression Shear Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0280 k Bottom along Y-Y 0.0280 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-4 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.07605 in at 4.027 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 568.13 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 8.0 ft0.400 ft0.2756X Axis +D+L 1.000 PASS PASS3.973 0.04444 0.0 ft0.366 ft0.4305X Axis +D+Lr 1.250 PASS PASS0.0 0.0 8.0 ft0.301 ft0.2837X Axis +D+0.750Lr+0.750L 1.250 PASS PASS3.973 0.02667 0.0 ft0.301 ft0.3931X Axis +D+0.750L 1.150 PASS PASS3.973 0.02899 0.0 ft0.324 ft0.3818X Axis +0.60D 1.600 PASS PASS0.0 0.0 8.0 ft0.240 ft0.1551X Axis . 15 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.809 +D+L -0.028 1.249-0.028 +D+Lr 0.869 +D+0.750Lr+0.750L -0.021 1.184-0.021 +D+0.750L -0.021 1.139-0.021 +0.60D 0.485 Lr Only 0.060 L Only -0.028 0.440-0.028 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 1.249 Axial, Base Min 0.060 Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.028 Ry, Top Max Ry, Top Min -0.028 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.076 4.027ftftinin 0.000 +D+Lr 0.0000 0.000 0.000ftftinin 0.000 +D+0.750Lr+0.750L 0.0000 0.057 4.027ftftinin 0.000 +D+0.750L 0.0000 0.057 4.027ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 Lr Only 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.076 4.027ftftinin 0.000 . 16 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 3.50 in1.50 in +Y +X 2x4 Load 1 Height = 8.0 ft1.30k Height = 8.0 ft1.30k 0.01klf 17 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x6Analysis Method : 19.5Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 5.50 in Area 8.250 in^2 Ix 20.797 in^4 Iy 1.547 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 34.867 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 19.50 ft, D = 0.410, Lr = 0.060 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070, W = 0.0160 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.9240 Location of max.above base 9.685 ft Applied Axial 0.4899k Applied Mx 0.5917 k-ft Load Combination +D+0.750Lr+0.750L+0.450W Load Combination +D+0.750Lr+0.750L+0.450W Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 33.106 psi 288.0Allowable Shear psi 0.07663 : 1 Bending Compression Shear Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.1560 k Bottom along Y-Y 0.1560 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 1.581 in at 9.815 ft above base for load combination : W Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 377.001 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 19.50 ft0.272 ft0.1482X Axis +D+L 1.000 PASS PASS9.685 0.06894 0.0 ft0.247 ft0.5910X Axis +D+Lr 1.250 PASS PASS0.0 0.0 19.50 ft0.201 ft0.1643X Axis +D+0.750Lr+0.750L 1.250 PASS PASS9.815 0.04136 0.0 ft0.201 ft0.4277X Axis +D+0.750L 1.150 PASS PASS9.815 0.04496 0.0 ft0.217 ft0.4261X Axis +D+0.60W 1.600 PASS PASS9.685 0.05909 0.0 ft0.159 ft0.7026X Axis +D+0.750Lr+0.750L+0.450W1.600 PASS PASS9.685 0.07663 0.0 ft0.159 ft0.9240X Axis 18 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About +D+0.750L+0.450W 1.600 PASS PASS9.685 0.07663 0.0 ft0.159 ft0.9051X Axis +0.60D+0.60W 1.600 PASS PASS9.685 0.05909 0.0 ft0.159 ft0.6485X Axis +0.60D 1.600 PASS PASS0.0 0.0 19.50 ft0.159 ft0.08582X Axis .Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.445 +D+L -0.068 0.445-0.068 +D+Lr 0.505 +D+0.750Lr+0.750L -0.051 0.490-0.051 +D+0.750L -0.051 0.445-0.051 +D+0.60W -0.094 0.445-0.094 +D+0.750Lr+0.750L+0.450W -0.121 0.490-0.121 +D+0.750L+0.450W -0.121 0.445-0.121 +0.60D+0.60W -0.094 0.267-0.094 +0.60D 0.267 Lr Only 0.060 L Only -0.068-0.068 W Only -0.156-0.156 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.505 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.156 Ry, Top Max Ry, Top Min -0.156 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.692 9.815ftftinin 0.000 +D+Lr 0.0000 0.000 0.000ftftinin 0.000 +D+0.750Lr+0.750L 0.0000 0.519 9.815ftftinin 0.000 +D+0.750L 0.0000 0.519 9.815ftftinin 0.000 +D+0.60W 0.0000 0.949 9.815ftftinin 0.000 +D+0.750Lr+0.750L+0.450W 0.0000 1.230 9.815ftftinin 0.000 +D+0.750L+0.450W 0.0000 1.230 9.815ftftinin 0.000 +0.60D+0.60W 0.0000 0.949 9.815ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 Lr Only 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.692 9.815ftftinin 0.000 W Only 0.0000 1.581 9.815ftftinin 0.000 . 19 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 5.50 in1.50 in +Y +X 2x6 Load 1 Height = 19.50 ft0.470k Height = 19.50 ft0.470k 0.02klf 20 21 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 E−W L/B =0.56 Cp =0.8 (Windward) Fig.27.3−1 Cp =0.0 N/A (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =0.0 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =1.26 Cp =−1.30 (Windward)Fig.27.3−1 Cp =0.00 (Leeward)Fig.27.3−1 qGCp -qiGCi =−15.96 (Windward) qGCp -qiGCi =0.00 Mono slope (Leeward) qh GCp(x component) =−2.50 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 34 13.5 459 4,903 34 13.5 459 0 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 36 3 108 −270 36 3 108 0 Ptotal =4,634 lbs (lrfd) =2,780 lbs (asd) < Seismic = 6,423 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 23 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 N−S L/B =1.79 Cp =0.8 (Windward) Fig.27.3−1 Cp =−0.342 (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =−5.8 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =0.84 Cp =0.00 N/A (Windward)Fig.27.3−1 Cp =0.00 N/A (Leeward)Fig.27.3−1 qGCp -qiGCi =0.00 (Windward) qGCp -qiGCi =0.00 (Leeward) qh GCp(x component) =0.00 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 19 15 285 3,044 19 15 285 −1,666 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 23 3 69 0 23 3 69 0 Ptotal =4,711 lbs (lrfd) =2,826 lbs (asd) < Seismic = 6,423 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 24 2022 CBC Seismic Criteria (based on the requirements of ASCE 7−16) 2022 CBC Section 1613 Earthquake Loads  Site Parameters: Site Class:DDefault Latitude =35.291 deg N Google Earth Longitude =120.657 deg W Google Earth Seismic Design Category:D USGS Design Maps SS =1.074 g USGS Design Maps Fa =1.20 Section 11.4.4 SMS =Fa SS =1.289 g (16−20) SDS =2/3 x SMS =0.859 g (16−22) SDS,MAX =2/3 x SMS,MAX =N/A g Calcs Pg. , Based on Section 12.8.1.3 S1 =0.396 g USGS Design Maps Fv =1.904 Table 1613.2.3(2) SM1 =Fv S1 =0.754 g (16−21) SD1 =2/3 x SM1 =0.503 g (16−23) ASCE 7−16 Section 12.8 Equivalent Lateral Force Procedure  Structural Parameters: hn =19.0 ft Ct =0.020 Table 12.8−2 x =0.75 " Ta =Ct(hn)x =0.18 sec (12.8−7) TL =8 sec > Ta Figure 22−14 R =6.50 Table 12.2−1 Ie =1.00 Table 1.5−2  Seismic Coefficient: Cs =SDS / (R/Ie)(12.8−2) =0.13 Cs,max =SD1 / [T x (R/Ie)]for T < TL (12.8−3) =0.42 Cs,min =0.044SDSIe > 0.01 (12.8−5) 0.04 Cs,min =0.5S1 / (R/Ie)for S1 > 0.6g (12.8−6) =0.03 light framed construction with plywd shear panels PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 25 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES  Seismic Base Shear: V =Cs W (12.8−1) =0.13 W =0.17 W =0.09 W =0.120 W Strength Level with Rho = 1.3 ASD Level ASD Level with Rho = 1.3 Strength Level ASCE 7−16 Section 12.8 26 Seismic Weights − 2−Story Portion (52X−74X) Second Floor Framing Height 8 ft +/− Roof Level Framing Height 17 ft +/− Roof Level Roof. . . w =18 psf A =725 sf W =13,050 lb Exterior Walls. . . w =18 psf L =68 ft htrib =5.0 ft W =6,120 lb Interior Walls. . . w =10 psf L =48 ft htrib =5.0 ft W =2,400 lb Total Sesimic Weight at Roof 21,570 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 27 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES Floor Level Typical Floor . . . w =17 psf A =538 sf W =9,146 lb Exterior Walls. . . walls above = 6120 lb w =18 psf L =68 ft htrib =10.0 ft W =18,360 lb Interior Walls. . . walls above = 2400 lb w =10 psf L =48.0 ft htrib =4.0 ft W =4,320 lb Total Sesimic Weight at Floor 31,826 lb Vertical Distribution Two Story Portion ~ ASD Level, Rho = 1.3 Level Seismic W V Height VxH % V Per SF Roof 21,570 2595 17 44108.4 59.0 3791 5.2 2nd floor 31,826 3828 8 30626.3 41.0 2632 4.9 6423 74735 6423 Total Base Shear V =7058 lb V =6423 lb LRFD ASD Level with Rho = 1.3 28 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES E−W Line Loads Roof Floor Line 0X. . .Line 0X. . . A trib. =265 ft2 A trib. =209 ft2 V dia. =1,383 lb V dia. =1,023 lb V in plane SW =391 lb V in plane SW =329 lb V roof =1,774 lb V total =1,774 lb V total =3,125 lb Line 22X. . .Line 22X. . . A trib. =363 ft2 A trib. =269 ft2 V dia. =1,895 lb V dia. =1,316 lb V in plane SW =195 lb V in plane SW =175 lb V roof =2,090 lb V total =2,090 lb V total =3,582 lb Line 34X. . .Line 34X. . . A trib. =98 ft2 A trib. =60 ft2 V dia. =512 lb V dia. =294 lb V in plane SW =195 lb V in plane SW =173 lb V roof =707 lb V total =707 lb V total =1,174 lb A total =725 ft2 A total =538 ft2 N−S Line Loads Roof Floor Line 0Y. . .Line 0Y. . . A trib. =265 ft2 A trib. =209 ft2 V dia. =1,383 lb V dia. =1,023 lb V in plane SW =524 lb V in plane SW =381 lb V roof =1,907 lb V total =1,907 lb V total =3,311 lb Line 9Y. . .Line 9Y. . . A trib. =98 ft2 A trib. =60 ft2 V dia. =512 lb V dia. =294 lb V in plane SW =247 lb V in plane SW =208 lb V roof =759 lb V total =759 lb V total =1,261 lb Line 19Y. . .Line 19Y. . . A trib. =363 ft2 A trib. =269 ft2 V dia. =1,895 lb V dia. =1,316 lb V in plane SW =589 lb V in plane SW =589 lb V roof =2,484 lb V total =2,484 lb V total =4,389 lb A total =725 ft2 A total =538 ft2 29 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)ωdl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0X 1,774 S 11.00 10.0 161 1 19.00 17,738 192 16,630 60 MST60 22X SEE 1ST FLOOR SW 34X 707 S 10.00 10.0 71 1 10.00 7,073 234 5,613 154 MST60 0X 3,125 S 5.50 8.0 568 4 2.75 12,502 263 477 5,404 HDUE7 H/W ratio penalized S8.05684 2.75 12,502 263 477 5,404 HDUE7 H/W ratio penalized 22X 3,582 S 9.00 19.3 398 2 9.00 68,948 401 7,781 7,196 HDUE9−4x H/W ratio penalized 34X 1,174 S 10.00 8.0 117 1 10.00 9,392 246 5,900 521 HDUE3 Project: ______________________________________________________ V (lbs) E−W 2nd FLOOR E−W 1st FLOOR 30 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)ωdl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0Y 1,907 S 22.00 11.0 87 1 22.00 20,977 405 47,017 N/A MST60 9Y 759 S 12.00 9.5 63 1 12.00 7,213 252 8,704 N/A MST60 19Y 2,484 S 22.00 8.0 113 1 34.00 19,875 288 79,855 N/A MST60 0Y 3,311 S 22.00 8.0 150 1 22.00 26,484 155 18,039 393 HDUE3 15Y 1,261 S 12.00 8.0 105 1 12.00 10,085 155 5,367 410 HDUE3 19Y 4,389 S 27.00 9.0 163 1 34.00 39,504 173 48,076 N/A #N/A Project: ______________________________________________________ V (lbs) N−S 2nd FLOOR N−S 1st FLOOR 31 SHEAR WALL SCHEDULE ALLOWABLE VALUESShear WallSubfloor Connection (2 story or more)Concrete ConnectionPlywood 1/Nailing (10d's)VallSill Size FastenerVallSill Size FastenerVallSDS @ 8" o.c. 456 SW1one side 6" o.c. 339 SW1 2x 16d's @ 6" o.c. 374 SW1 2x 5/8" AB @ 4'-0" o.c. 372 SW1one side 4" o.c. 510 SW2 3x SDS @ 6" o.c.608 SW23x 5/8" AB @ 2'-8" o.c. 707 SW2one side 3" o.c.664 SW33x SDS @ 4" o.c. 912 SW3 3x 5/8" AB @ 2'-8" o.c. 707 SW3one side 2" o.c.869 SW43x SDS @3" o.c. 1216 SW4 3x 5/8" AB @ 1'-4" o.c. 1415 SW4Top Pl. Shear Clip ConnectionVallA35 @ 24" o.c.325 SW1A35 @ 12" o.c. 650 SW2A35 @ 8" o.c. 975 SW3A35 @ 6" o.c. 1300 SW4Shear Wall CapacityNOTES:Vall6" o.c.325SW11. Shear wall allowables based on NDS Table 4.3A4" o.c.510SW23" o.c.664SW32. Subfloor nailed connection allowables based on NDS Table 11N2" o.c.869SW4 2x sill, 16d's - Z = 1.6x118=188# ea.3. Subfloor SDS connection is Simpson SDS 1/4" dia.x 6" screws w/allowables per SimpsonSDS 1/4"x6"=190# x 1.6 = 304# ea.Holdowns4. Subfloor lag screw allowables based on NDS Table 11.5 for 3x sillMin.1/2" dia x 8" = 1.6x390=620# ea.Type Uplift Cap. ChordHDUE3 37902-2x5. Concrete connection allowables based on NDS Table 11EHDUE5 53752-2x2x sill, 5/8" dia. Bolts - Z = 1.6x930=1488# ea.HDUE766752-2x3x sill, 5/8" dia. Bolts - Z = 1.6x1180=1888# ea.HDUE9 84254x43x sill, 3/4" dia. Bolts - Z = 1.66x1540=2464# ea.6. Top Pl. shear clip connection is Simpson A35 w/allowables per SimpsonA35=650# ea.7. Holdown allowables per Simpson current catalog32 E-W Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 19.0 1.16 ok VDIA. - LINE 22X =1,895 lbs vdia. = 1,895 lbs /19.0 ft = 99.8 plf →214.3 plf D/C =0.5 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 10.0 2.20 ok VDIA. - LINE 22X =1,316 lb vdia. = 1,316 lbs /10.0 ft = 131.6 plf →214.3 plf D/C =0.6 (NDS Table 4.2C) N-S Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 19 22.0 0.86 ok VDIA. - LINE 19Y =1,895 lbs vdia. = 1,895 lbs /22.0 ft = 86.2 plf →214.3 plf D/C =0.4 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 19 14.5 1.31 ok VDIA. - LINE 19Y =1,316 lb vdia. = 1,316 lbs /14.5 ft = 90.8 plf →214.3 plf D/C =0.4 (NDS Table 4.2C) 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 33 Dia. chord design: line Vdia.(ASD)q = Vdia./L L D chord force Connector Connection Cap. D/C lb plf ft ft lbs MIN.lbs 0Y/19Y Roof 3,791 172 22 19 549 12−16d 2,447 0.22 0Y/19Y Floor 2,632 120 22 10 724 12−16d 2,447 0.30 Chord Force =qL2/D top pl. splice 12−16d 2,447 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 34 Collector Analysis (ASCE 12.10.2) Roof… Line 22X 1.25V = 2,369 lbs Ltotal =19.0 ft Lshearwall =9.0 ft v1 = V / L total =124.70 plf v2 = V / Lshearwall =263.25 plf v1 -v2 =-138.55 plf SW Distance Length (ft) 9.0 10.0 unit shear (plf -138.55 124.70 Drag load(lbs)0 -1247 0 Max. Drag Load =1247 lb (See above) 12 - 16d 2447 lb (calc. pg. ) D/C =0.51 Simp. CS16 1705 lb (Simp. Catalog ) D/C =0.73 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 35 Floor… Line 22X 1.25V = 1,645 lbs Ltotal =19.0 ft Lshearwall =9.0 ft v1 = V / L total =86.58 plf v2 = V / Lshearwall =182.79 plf v1 -v2 =-96.20 plf SW Distance Length (ft) 9.0 10.0 unit shear (plf -96.20 86.58 Drag load(lbs)0 -866 0 Max. Drag Load =866 lb (See above) 12 - 16d 2447 lb (calc. pg. )D/C =0.35 Simp. CS16 1705 lb (Simp. Catalog ) D/C =0.51 36 Nail Connection Structural Element: Nail : Species: Adjustment Factors: CM =1.00 CΔ =1.00 CD =1.60 Ct =1.00 Ceg =1.00 Cg =0.98 Cdi =1.00 Ctn =1.00 Z =131 lb (10 dia. min. pentration reduction included) m(1-m 2n)1+REA 1-m n =12 nails D =0.162 in s =1.5 in Es =1,600,000 psi Em =1,600,000 psi NDS Table 4A As =8.25 in2 Am =8.25 in2 EsAs EmAm EmAm EsAs γ = (180,000)(D 1.5)=11,737 lb/in u =1+γs/2 x (1/EmAm+1/EsAs)=1.00 m =u-(u2-1)1/2 =0.95 =0.98 Shear Plate Adjusted Design Value: Z’ =Z x CDCMCtCgCΔCegCdiCtn NDS Table 10.3.1 = 204 lb/ea. Z’ (12−16d) =2,447 lb Top plates splice 12 − 16d DF No. 2 Cg = NDS (10.3−1)n[(1+REAmn)(1+m)-1+m2n] REA =lessor of or =1.0 x PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 37 Foundation Design Allowable soil bearing pressure =1500 psf (CBC Table 1806.2) Footing Width W =15 in Footing Depth D=21 in Gridline 0Y /19Y (D+0.75Lr+0.75L) Roof DL =207 plf 207 plf Roof Lr =230 plf 173 plf Floor DL =11 plf 11 plf Floor LL =27 plf 20 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =835 plf 771 plf Soil bearing = 668 psf (Ptotal / W) <1500 psf Gridline 0X/34X (D+0.75Lr+0.75L) Roof DL =54 plf 54 plf Roof Lr =60 plf 45 plf Floor DL =106 plf 106 plf Floor LL =250 plf 188 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =830 plf 753 plf Soil bearing = 664 psf (Ptotal / W) <1500 psf Gridline 22X (D+0.75Lr+0.75L) Roof DL =54 plf 54 plf Roof Lr =60 plf 45 plf Floor DL =187 plf 187 plf Floor LL =440 plf 330 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =1,101 plf 976 plf Soil bearing = 881 psf (Ptotal / W) <1500 psf PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 38 39 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: STAIRSDescription : Wood Beam Design :SJ Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x8, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.055 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 1.500 inft 8.26 psi Fb : Allowable : 1,242.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.046 : 1 2.400 ft 68.32 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.001 in Transient Upward 0.000in Total Downward 0.002 in Total Upward 0.000 in 0.02 0.080.02 0.08 Ratio 9999 9999Ratio LC: L Only LC: +D+L LC:LC: Wood Beam Design :SS (Int. Stair Stringer governs) Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x6, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.50 ft .Design Summary Max fb/Fb Ratio =0.208 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 2.000 inft 21.59 psi Fb : Allowable : 1,170.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.120 : 1 0.000 ft 243.69 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.010 in Transient Upward 0.000in Total Downward 0.013 in Total Upward 0.000 in 0.03 0.120.03 0.12 Ratio 4597 3591Ratio LC: L Only LC: +D+L LC:LC: 40 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: Wood Beam Design :SB1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.0 ft 1Point: D = 0.0150, L = 0.060 k @ 0.0 ft 2Point: D = 0.030, L = 0.120 k @ 1.50 ft 3Point: D = 0.0150, L = 0.060 k @ 3.0 ft .Design Summary Max fb/Fb Ratio =0.015 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 2.000 inft 3.00 psi Fb : Allowable : 1,100.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.017 : 1 2.000 ft 16.95 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.000 in Transient Upward 0.000in Total Downward 0.000 in Total Upward 0.000 in 0.03 0.090.09 0.27 Ratio 9999 9999Ratio LC:LC: +D+L LC:LC: Wood Beam Design :SB2 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x8, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.50 ft 1Point: D = 0.060, L = 0.20 k @ 0.0 ft 2Point: D = 0.120, L = 0.40 k @ 1.50 ft 3Point: D = 0.060, L = 0.20 k @ 3.0 ft .Design Summary Max fb/Fb Ratio =0.145 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 1.500 inft 19.65 psi Fb : Allowable : 1,300.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.109 : 1 2.400 ft 188.08 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.003 in Transient Upward 0.000in Total Downward 0.003 in Total Upward 0.000 in 0.15 0.490.15 0.49 Ratio 9999 9999Ratio LC: L Only LC: +D+L LC:LC: 41 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: Wood Beam Design :C1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x4, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads 1Point: L = -0.20 k @ 9.167 ft .Design Summary Max fb/Fb Ratio =0.709 : 1 Max Reactions (k)HEWSLLr L OnlyLoad Comb : Span # 1 Left Support D in 6.000 inft 24.49 psi Fb : Allowable : 1,500.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : L Only 180.00 psi fb : Actual : Max fv/FvRatio =0.136 : 1 6.000 ft 1,063.67 psi at atfv : Actual : Ratio 0 Ratio 152 Max Deflections Transient Downward 0.000 in Transient Upward 0.000in Total Downward 0.120 in Total Upward -0.498 in 0.11-0.31 Ratio 9999 601Ratio LC:LC: L Only LC:LC: L Only <0 Wood Beam Design :C2 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x4, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads 1Point: L = -0.20 k @ 6.167 ft .Design Summary Max fb/Fb Ratio =0.709 : 1 Max Reactions (k)HEWSLLr L OnlyLoad Comb : Span # 1 Left Support D in 3.000 inft 25.85 psi Fb : Allowable : 1,500.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : L Only 180.00 psi fb : Actual : Max fv/FvRatio =0.144 : 1 0.000 ft 1,063.67 psi at atfv : Actual : Ratio 0 Ratio 226 Max Deflections Transient Downward 0.000 in Transient Upward 0.000in Total Downward 0.030 in Total Upward -0.335 in 0.21-0.41 Ratio 9999 1203Ratio LC:LC: L Only LC:LC: L Only <0 42 (Guardrail Post) Simp. DTT2Z w/ 1/2" dia. x 3" embed. lag screw (lag screw governs) Allow. Tension = 1 11/16" thr'd length x 378 #/in = 638# > 310# Simp. DTT2Z w/ 1/2" dia. x 3" embed. lag screw (lag screw governs) Allow. Tension = 1 11/16" thr'd length x 378 #/in = 638# > 410# (Guardrail Post) Wood Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 DESCRIPTION:C3 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 Material Properties Beam Bracing :Completely Unbraced Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 4x4 Span = 3.167 ft 1 2 L(0.2) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Point Load : L = 0.20 k @ 3.167 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio Maximum Shear Stress Ratio 4x4 0.136 Section used for this span4x4 : 10.709 =: 1 Load Combination L Only L Only Span # where maximum occurs Span # 1 Location of maximum on span 0.000ft 24.49 psi= 1,500.00psi Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination = = = 180.00 psi== 0.000 ft= = 1,063.67psi Maximum Deflection 0 >=120 442 Ratio =0 >=120 Max Downward Transient Deflection 0 in 0 Ratio = >=120 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.172 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v n/a n/a Span: 1 : L Only n/a NDS2024 NDS2024 .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 0.0 0.00 0.00.0 1.00Length = 3.167 ft 1 0.90 1.500 1.001.00 1.00 1,350.0 0.00 162.01.00 0.01.00 1.00L Only 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.167 ft 1 0.709 0.136 1.00 1.500 1.001.00 1.00 0.63 1,063.7 1,500.0 0.20 180.01.00 24.51.00 1.00+0.750L 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.167 ft 1 0.425 0.082 1.25 1.500 1.001.00 1.00 0.48 797.8 1,875.0 0.15 225.01.00 18.41.00 . 43 Wood Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 DESCRIPTION:C3 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: LocationLoad CombinationMax. LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl L Only1 0.1717 3.167 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.200 Max Upward from Load Combinations 0.150 Max Upward from Load Cases 0.200 L Only 0.200 +0.750L 0.150 44 Stork, Wolfe, & Associates lEngineers A 7ropcl,, Job +: LE 0 6z,D |al,e'? aqe c"b b,s ?o oS,. AS'u r ?r 6 c g lb r** T ir''e 4'%4b T^tt itr*? *" I ii_j :* t-t-l-ri H-1ffl f"rffi ;-i_l -l--t-.]- 1- 1,-'+r|]+ Il_ITil__F H-.J'-H +-+-r-+--i l_j___L ti- 1- I r'* 1- -1 lt I _l_ t_il i-i II H- I:I i t 1- 1'--:--- -#---1--1- t-.i i_.1 I i LJ rrtt-fr 1-l+.-t I { f' I t- I-f il;--.i -i+ I I -*--r- i-i-ffiL[il_ -t- J il _ L_* -1 I 1-t- +- 1-1- _I_I_] H j-]-:=tr ltr Lt I' .-1._ I i I I i I 45 4x4 DESCRIPTION THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. SITE INFORMATION EXISTING BUILDING INFORMATION JURISDICTION ZONING APN STREET ADDRESS GROSS LOT SIZE BUILDING AREAS PROPOSED INFORMATION TWONUMBER OF STORIES R-3 (RESIDENTIAL)OCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE SPRINKLERED CLASS A ROOFINGROOF RATING TWO STORYNUMBER OF STORIES R-3 (RESIDENTIAL) / UOCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSEDFIRE SPRINKLERS CITY OF SAN LUIS OBISPO LOW DENSITY RESIDENTIAL (R-1) 001-056-052 619 A GROVE STREET, SAN LUIS OBISPO, CA 93401 0.08 ACRES (3,589 SF) CLASS AROOF RATING 25 FEET ALLOWEDMAXIMUM HEIGHT PROPERTY IS NOT LOCATED WITHIN A HIGH FIRE RISK AREA OR FLOOD PLAIN AREAHAZARDS LOT COVERAGE MAX 40% = 3,589 X 0.4 = 1,436 SF. PROPOSED = 862 SF. 862 / 3,589 = 24% (ADU EXCLUDED FROM LOT COVERAGE CALCULATIONS PER MC § 17.70.120(B)(5)) 1 SPACE PROVIDED IN DRIVEWAY PER PREVIOUS LOT SPLITPARKING LEGAL DESCRIPTION CY SLO PM 84/92-93 PAR 2 1 SPACE PROVIDED IN DRIVEWAYPARKING NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSED T1.0 Title Sheet, General Notes + Project Data Sheet Index OWNER Project Directory SOILS ARCHITECT CWA STUDIOS 1668 SYDNEY STREET SAN LUIS OBISPO. CA 93401 CONTACT: CHRIS ALLEN, AIA. 805 286 5186 Drawing Log SET ISSUE DATE REVISION Project Notes ENERGY CARSTAIRS ENERGY CALCULATIONS 2238 BAYVIEW HEIGHTS DRIVE, SUITE E LOS OSOS, CA 93402 CONTACT: TIM CARSTAIRS. 805 904 9048 Project Data T1.1 INDEX, DATA + NOTES STRUCTURAL Calgreen Mandatory Measures 1.PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL SHALL MANAGE STORMWATER DURING CONSTRUCTION. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. CALGREEN 4.106.2.2 2.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED AND SHALL COMPLY WITH THE PLUMBING FIXTURE AND FITTINGS SCHEDULE ON THIS SHEET. CALGREEN 4.303.3.1 3.AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1 - CONTROLLERS SHALL BE WEATHER- OR SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANT WATERING NEEDS AS WEATHER OR SOIL CONDITIONS CHANGE. 2 - WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). CALGREEN 4.304.1 4.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE CLOSED WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY TO PREVENT PASSAGE OF RODENTS. CALGREEN 4.406.1. 5.RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 60% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4; OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. CALGREEN 4.408.1 6.DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION PER CALGREEN 4.504.1. 7.ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS PER CALGREEN 4.504.2.1. 8.PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.2.2. 9.AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS PER CALGREEN 4.504.2.3. 10.DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED PER CALGREEN 4.504.2.4. 11.CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.3. 12.EIGHTY (80) PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERINGINSTITUTE (RFCI) FLOORSCORE PROGRAM PER CALGREEN 4.504.4. 13.PARTICLEBOARD, MEDIUM FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR OR EXTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS PER CALGREEN 4.504.5. 14.VAPOR RETARDER AND CAPILLARY BREAK OF 4” THICK BASE OF ½” OR LARGER CLEAN AGGREGATE SHALL BE INSTALLED AT SLAB ON GRADE FOUNDATIONS PER CALGREEN 4.505.2. 15.MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING SHALL BE CHECKED BEFORE ENCLOSURE PER CALGREEN 4.505.3. 16.BATHROOM EXHAUST FANS SHALL BE DUCTED TO TERMINATE OUTSIDE AND BE PROVIDED IN EVERY BATHROOM PER CALGREEN 4.506.1. 17.WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED LOUVERS OR COVERS WHICH CLOSE WHEN THE FAN IS OFF. COVERS OR LOUVERS SHALL HAVE A MINIMUM INSULATION VALUE OF R-4.2 PER CALGREEN 4.507.1. 18.PER CALGREEN 4.507.2 DUCT SYSTEMS ARE SIZED, DESIGNED, AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS: 1. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ACCA (MANUAL J) OR EQUIVALENT. 2. SIZE DUCT SYSTEMS ACCORDING TO ACCA 26-D (MANUAL D) OR EQUIVALENT. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S (MANUAL S) OR EQUIVALENT. 19.OPERATION + MAINTENANCE MANUAL TO BE SUPPLIED AT FINAL INSPECTION. 20.MANAGE STORMWATER PER CALGREEN CODE REQUIREMENTS. 4106.2 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 25.1222 Deferred Submittals / Separate Permits 1.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDER-DRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. SURVEY MBS LAND SURVEYS 3559 SOUTH HIGUERA ST. SAN LUIS OBISPO CA 93401 CONTACT: MICHAEL B STANTON 805 594 1960 ARCHITECTURAL1.ALL WORK SHALL BE IN CONFORMANCE WITH THE 2022 EDITIONS OF THE CALIFORNIA BUILDING CODES 2.ANY/ALL DEFERRED SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT AND/OR PROJECT ENGINEER PRIOR TO SUBMISSION TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL. 3.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. 4.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. 5.THE PUBLIC IMPROVEMENTS SHALL BE SUBSTANTIALLY COMPLETE TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR PRIOR TO FINAL INSPECTION APPROVALS AND/OR OCCUPANCY OF ANY BUILDING. 6.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER AND SIDEWALK OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 7.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 805 781 7554 WITH AT LEAST A 48 HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. 8.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. 9.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. 10.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED DURING ALL CONSTRUCTION AND GROUND DISTURBING ACTIVITIES PER THE CITY OF SAN LUIS OBISPO 11.TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN PERMANENT IMPROVEMENTS, PLANTINGS AND FACILITIES ARE IN PLACE. TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION APPROVALS. 12.THE EXISTING SEWER LATERAL SHALL BE TELEVISED AND APPROVED FOR REUSE OR SHALL BE REPAIRED/REPLACED. THE INSPECTION SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE UTILITIES DEPARTMENT PRIOR TO ISSUANCE OF A BUILDING PERMIT. 13.ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE VERTICAL AND GREATER AND AREAS USED TO CONVEY CONCENTRATED DRAINAGE SHALL BE PREPARED AND MAINTAINED TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED NO LATER THAN 30 DAYS PRIOR TO A REQUEST FOR FINAL INSPECTION APPROVAL. 14.REMODELING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS A VIOLATION OF CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELERS AND PAINTERS ARE REQUIRED TO USE "LEAD-SAFE" WORK PRACTICES PURSUANT TO TITLE 17, CA CODE OF REGULATIONS SECTION 36050. 15.PRIOR TO ANY DEMOLITION OR GRADING THE CONTRACTOR SHALL PROTECT ANY TREES ADJACENT TO THE WORK ZONE. 16.THE MANDATORY PROVISIONS OF CALGREEN CHAPTER 4 SHALL BE APPLIED TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. CALGREEN 301.1.1 17.ON AND AFTER JANUARY 1, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. CALGREEN 301.1.1 18.APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER ORDINANCE OR LAW. CBC 105.4 19.THIS PROJECT IS LOCATED IN THE HIGH FIRE SEVERITY ZONE AS PER CITY OF SAN LUIS OBISPO California Building Code Chapter 7A Req. THE CITY OF SAN LUIS OBSIPO IS CONSIDERED A "COMMUNITY AT RISK" DUE TO THE THREAT OF WILDFIRE IMPACTING THE URBAN COMMUNITY. THE CITY SHALL CONTINUE TO ENHANCE THE FIRE SAFETY AND CONSTRUCTION CODES FOR NEW BUILDINGS IN ORDER TO REDUCE THE RISK OF URBAN FIRES THAT MAY RESULT FROM WILDFIRES. NEW BUILDINGS CITYWIDE SHALL INCORPORATE THE FOLLOWING CONSTRUCTION METHODS AND MATERIALS: IGNITION RESISTANT EXTERIOR WALL COVERINGS; FIRE SPRINKLER PROTECTION IN ATTIC AREAS (AT LEAST ONE "PILOT HEAD"); EMBER RESISTANT VENT SYSTEMS FOR ATTICS AND UNDER FLOOR AREAS, PROTECTED EAVES AS IDENTIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7A. CRC R337.1.2. STORK, WOLFE & ASSOCIATES 555 CHORRO ST. SUITE A1 SAN LUIS OBISPO, CA 93401 CONTACT: JUSTIN WOLFE, PE. PH: 805 548 8604 STRUCTURAL AS1.1 ARCHITECTURAL SITE PLAN T1.2 A3.1 EXISTING BUILDING ELEVATIONS A5.2 ARCHITECTURAL DETAILS S0.1 STRUCTURAL GENERAL NOTES S1.4 TYPICAL DETAILS S1.2 TYPICAL DETAILS S2.2 S2.3 ROOF FRAMING PLAN SECOND FLOOR FRAMING PLAN S0.2 STRUCTURAL GENERAL NOTES S1.1 TYPICAL DETAILS A4.1 PROPOSED BUILDING SECTIONS S1.3 TYPICAL DETAILS S2.1 FOUNDATION PLAN S3.1 STRUCTURAL DETAILS CALGREEN MANDATORY MEASURES G r o v e S t r e e t R e s i d e n t i a l A d d i t i o n 6 1 9 A G r o v e S t r e e t , S a n L u i s O b i s p o , C A 9 3 4 0 1 A5.1 ARCHITECTURAL DETAILS N/A T1.3 CALGREEN MANDATORY MEASURES Vicinity Map S3.2 STRUCTURAL DETAILS Construction Documents for SV1.1 EXISTING TOPOGRAPHIC SURVEY PROJECT LOCATION CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 BUILDING AREAS (EXISTING) (PROPOSED) PRIMARY RESIDENCE (EXISTING) 1,287 SQ. FT. PROPOSED ADU GROUND FLOOR 490 SQ. FT. SECOND FLOOR 430 SQ. FT. TOTAL (INCLUDING EXISTING RESIDENCE) 2,292 SQ. FT. N/ASOILS REPORT JOHN ROURKE 163 SERRANO HEIGHTS DRIVE SAN LUIS OBISPO. CA 93405 CONTACT: JOHN ROURKE. PH: 805 440 4973 A2.1 PROPOSED FLOOR PLANS + ROOF PLAN A3.2 PROPOSED BUILDING ELEVATIONS AS1.2 ARCHITECTURAL SITE DETAILS Standard Public Works Notes a.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. (THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. b.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY, WITHIN CITY EASEMENTS, OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. c.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK, OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. d.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST A 48-HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. e.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. f.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. g.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. h.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. i.ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT LESS THAN 2% SHALL HAVE FINAL GRADIENTS CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER PRIOR TO FINAL INSPECTION APPROVALS. Stormwater Compliance Summary THE PROJECT IS NOT A REGULATED PROJECT SUBJECT TO REGIONAL WATER QUALITY CONTROL BOARD RESOLUTION R3-2013-0032 “POST CONSTRUCTION STORMWATER MANAGEMENT REQUIREMENTS FOR DEVELOPMENT PROJECTS IN THE CENTRAL COAST REGION” BASED ON THE FOLLOWING: ☒PROJECT DOES NOT CREATE AND/OR REPLACE 2,500 SQUARE FEET OR MORE OF IMPERVIOUS AREA ☐PROJECT TYPE IS LISTED IN SECTION B.1.B (STATE WHICH): Applicable Governing Codes: 2022 2022 2022 CALIFORNIA BUILDING CODE, VOLUMES 1+2 CALIFORNIA ELECTRIC CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA GREEN BUILDING CODE CALIFORNIA FIRE CODE CALIFORNIA ENERGY CODE CALIFORNIA RESIDENTIAL CODE 2022 2022 2022 2022 2022 SAN LUIS OBISPO MUNICIPAL CODE NOT TO SCALE T1.4 ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS T1.0 A5.3 FIRESTOPPING DETAILS MEP1 ELECTRICAL FLOOR PLAN + NOTES MEP2 MEP CALCULATIONS SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0220 HERS Feature Summary THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY A CERTIFIED HERS RATER AS A CONDITION FOR MEETING THE MODELED ENERGY PERFORMANCE FOR THIS COMPUTER ANALYSIS. ADDITIONAL DETAIL IS PROVIDED IN THE BUILDING TABLES ON SHEET T1.3. REGISTERED CF2RS AND CF3RS ARE REQUIRED TO BE COMPLETED IN THE HERS REGISTRY •INDOOR AIR QUALITY VENTILATION •KITCHEN RANGE HOOD •VERIFIED EER/EER2 •VERIFIED SEER/SEER2 •VERIFIED REFRIGERANT CHARGE •AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7) •VERIFIED HSPF •VERIFIED HEAT PUMP RATED HEATING CAPACITY •WALL-MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 FT2 (SC3.4.5) • DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONDITIONED SPACE (SC3.1.4.1.8) A5.4 ARCHITECTURAL DETAILS AS1.0 SITE DEMO / GRADING PLAN T1.1 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 Y ALL Y Y ALL Y CONT CONT N/A N/A N/A N/A N/A N/A N/A N/A Y ALL Y OWNER Y ALL Y CONT Y OWNER Y CONT Y CONT Y CONT Y OWNER Y OWNER N/A N/A N/A T1.2 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 N/A N/A Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y OWNER Y CONT Y CONT Y CONT T1.3 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 T1.4 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SV1.1 Existing Topographic Survey TOPOGRAPHIC MAPJOHN TO ESTABLISH SOUTHEAST CORNER OF BLOCK 1 N1°57'52"E 64.00'M&R6EXISTING OUT BUILDING TO BE REMOVED PRIOR TO RECORDING MAPN1°57'52"E 50.00'*M&D1N88°04'24"W 119.99'*M&D1 N88°04'24"W 119.99'*M&D1 N1°57'52"E 50.00'*M&D1N1°57'52"E 50.00'CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 AS1.0 Site Demo / Grading Plan Sheet Reference Notes 1.PORTION OF DRIVEWAY TO BE REMOVED FOR NEW UTILITIES, SHADED. 2.NEW TOPOGRAPHY LINES THROUGH SITE GRADING TO ALLOW FOR DRAINAGE TO FLOW TOWARDS THE SUMP PUMP VIA A 1% SLOPE. 3.AREA OF SIDEWALK TO BE REMOVED TO PLACE SIDEWALK UNDER-DRAIN, AND TO BE RESTORED SS SS SS SS SS SS SSWWWWWWWWWWWC.O. C.O.SD6in226'VCP8in Cast Iron330.4' INV. 330.6' INV. 331.1' FG. 331.5' FG. 331.6' TG. 331.4' TG. 331.7' FG. 330.0' INV. 331.0' TG. 329.0' INV. 329.0' INV.330331330SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD SDSD SD 23'-0"12'-0" 35'-0" 70'-0" RIGHT-OF-WAY 22 1 5% SLO P E 2% SLOPE 2% SLOPE3 168420 Architectural Site Plan11/8" = 1'-0" with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 TOP GRADE ARCHITECTURAL TG. Abbreviations FINISH GRADEFG. FINISH FLOORFF. FINISH SURFACEFS. 23'-0"12'-0" 35'-0" 70'-0" RIGHT-OF-WAY INVERTINV. 26 10'-2 1/2"27 28 29 Architectural Site Details Liberty Grinder Pump Specification1N.T.S. DensGlass Installation Guide - Fastening and Framing N.T.S.4 Sidewalk Underdrain N.T.S.3 AS1.2 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 Proposed Floor Plans, Roof Plan, and Schedules CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 0 1 2 84 1/4" = 1'-0" Proposed First Floor Plan1 0 1 2 84 1/4" = 1'-0" Proposed Second Floor Plan2 A2.1 Floor Plan Reference Notes 1.HARDWOOD VANITY CABINETS 20" DEEP WITH FINISH COUNTER HEIGHT OF +36" A.F.F. . 2.QUARTZITE COUNTERTOP. USE 2CM SLAB THICKNESS AS DROP EDGE CEASARSTONE, OR EQUAL. COLOR TO BE SELECTED BY OWNER. 3.SINK: KOHLER, OR EQUAL. FAUCET: HANSGROHE BATHROOM FAUCET, OR EQUAL. 4.MIRROR FROM TOP OF COUNTER TO CEILING OR PER OWNERS SELECTION. 5.SHOWER HEAD: KOHLER, OR EQUAL. CONTROLS: THERMOSTATIC/PRESSURE BALANCE MIXING VALVE TO PROVIDE SCALD + THERMAL SHOCK PROTECTION. 6.66" PRE-FABRICATED FIBERGLASS TUB. TOP @ 18" A.F.F.. 7.TOILET: LOW-FLOW AMERICAN STANDARD CADET 3, OR EQUAL. 8.GUARDRAILS; SHALL HAVE A MINIMUM HEIGHT OF 42". INTERMEDIATE RAILINGS SHALL BE SPACED AT A MAXIMUM OF 3-3/4". HANDRAILS; SHALL HAVE A HEIGHT OF 36" WHERE LOCATED IN STAIRWAYS. A MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT IS 31-1/2" WHERE A HANDRAIL IS INSTALLED ON ONE SIDE OF THE STAIRWAY, AND 27" WHERE HANDRAILS ARE INSTALLED ON BOTH SIDES. 9.STAIRS, 7-3/4" MAX RISER / 10" MIN. TREAD DEPTH. TO BE IN COMPLIANCE WITH CRC R311.7. 10.NEW FIXTURES PER CALGREEN MANDATORY MEASURES. 11.INFILL WINDOWS IN EXISTING RESIDENCE WITH OPAQUE WALL. 12.6" SEISMIC GAP BETWEEN EXISTING RESIDENCE AND PROPOSED ADU AS SHOWN, REFERENCE DETAIL 7 ON SHEET A5.2 FOR MORE DETAIL. 0 1 2 84 1/4" = 1'-0" Proposed Roof Plan3 Legend X NEW 2X4 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS NEW 2X6 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS DOOR / WINDOW CALLOUTS; SEE DOOR & WINDOW SCHEDULE THIS SHEET FOR DETAILS 1-HR RATED ASSEMBLY BETWEEN NEW ACCESSORY DWELLING UNIT AND EXISTING RESIDENCE. NEW RATED WALL SHALL EXTEND FROM CONCRETE SLAB TO BOTTOM OF PROPOSED ROOF SHEATHING IN ALL LOCATIONS. REFERENCE DETAIL 4 & 6 ON A5.2 FOR ADDITIONAL INFORMATION. WINDOW AND DOOR NOTES: 1.ALL EXTERIOR DOORS SHALL BE WEATHER-STRIPPED AND SHALL FEATURE WATER-RESISTANT THRESHOLDS AND/OR DOOR BOTTOMS 2.THRESHOLDS SHALL BE 3/4" MAXIMUM AT SLIDERS AND 1/2" MAXIMUM FOR OTHER DOORS. 3.TEMPERED GLAZING SHALL BE PROVIDED WHERE INDICATED IN THESE PLANS IN ACCORDANCE WITH THE REQUIREMENTS FOR HAZARDOUS LOCATIONS [CBC 2406.3] 4.LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-½" LOWER THAN TOP OF THRESHOLD. (THE LANDING / FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 7-¾" BELOW TOP OF THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR.) [R311.3.1] 5.PROVIDE LOCKSETS AND DEADBOLTS ON ALL EXTERIOR HINGED DOORS. 6.WINDOWS THAT SERVE AS A REQUIRED MEANS OF EGRESS ARE DENOTED ON THE EXTERIOR ELEVATIONS. EGRESS WINDOWS SHALL HAVE A MAX DIMENSION OF 44" TO THE OPENING ABOVE THE FLOOR, PROVIDE 5.7 SQUARE FEET OF CLEAR EGRESS AREA WITH 24" MIN. HEIGHT AND 20" MIN. WIDTH. Window Schedule WIDTH HEIGHT FRAMETYPE A 4'-0" B HEADER +80" Door Schedule WIDTH HEIGHT FRAME PANELTYPE 6'-8"EXTERIOR - HINGED 2 1 # # VINYL4'-0" GLAZED, TEMPEREDWOOD 3'-8"2'-6" +80" 3'-0" 6'-8" INTERIOR - HINGED 3 S.C. SLABWOOD 2'-8" VINYLSLIDING SLIDING INTERIOR - HINGED A CLASS "A" COMP SHINGLE ROOFING TO MATCH EXISTING. PRODUCT SHALL MEET OR EXCEED UL 790 (CLASS A FIRE RESISTANCE STANDARD). A DRIP EDGE SHALL BE PROVIDED AT EAVES AND RAKE EDGES OF SHINGLE ROOFS PER R905.2.8.5. 3.METAL GUTTER AND DOWNSPOUT PROVIDED, AS REQUIRED. LOWER ROOF DRAINS TO CONNECT TO LEADERS DOWN TO SITE DRAINAGE CONNECTIONS. INLET SHALL BE EQUIPPED WITH A LEAF STRAINER TO PROHIBIT DEBRIS FROM ENTERING THE DOWNSPOUT. 1 1 2 2 2 3 3 1'-7"1'-10 1/2"1'-10 1/2"1'-10 1/2"1'-8"1'-8"3'-2" 3'-2"3'-1"6" SEISMICGAPLIVING ROOM 101 KITCHEN 102BATH 105 BEDROOM 106 LAUNDRY 104 HALL 103 BATH 203 BEDROOM 202 HALL 201 1/A4.11/A4.1BEDROOM 204 BEDROOM 205 6'-8"4 3'-0"INTERIOR - HINGED S.C. SLABWOOD A3.1 Existing Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c 4 D 3/4 D 3/4 D 4 D 1 A 2 F 2 F 6 C 8 - 10 - A3.2 Proposed Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c FIRST LEVEL (0'-0") (FF = 333') F.F. @ SECOND LEVEL (9'-0")(FF = 342') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') A4.1 Proposed Building Sections CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c -0") TOP PLATE OF WALL (17'-0") WINDOW & DOOR HEADERS (15'-8") AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') Architectural Details CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a Penetrations and Firestopping NOT TO SCALE Bi-Pass Door - Head and Jamb Typical Jamb, Head, and Sill Installation @ Exterior Windows + Doors 3" = 1'-0" 5 1 Through Wall Penetrations and Firestopping N.T.S.4 SYSTEM NO. W-L-1054NOT TO SCALE 8 3" = 1'-0" 6 A5.2 EXTERIOR 7/8" 3-COAT CEMENTIOUS PLASTER SIDING OVER MIN. TWO LAYERS GRADE D BUILDING PAPER. Firestopping Details A5.3 CAD FILE CWA JOB NO DRAWN BY PLOT DATE 2020 1 sheet: sheet data: revision: sheet title: REV DESCRIPTION BYISSUE DATE SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1 SYDNEY STREET, SLO, CA 3401 EMAIL CWA.ARCH GMAIL.COM TELEPHONE 0.2.1 AIA, LEED AP, C-31 CHRISTOPHER W. ALLEN C31 EXP. 0.30.2LIC E N S E D A RCHITE C TS TATE OF C A L I F O R N IA12/22/2 2.0220 legal stuff: THE USE OF THES E PLANS AND SPECIFICAT IONS SHALL BE RESTRICTED TO THE USE OF THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE UNLESS OTHERWISE APPROVED BY THE A RC HITECT. TITL E TO T HES E P LA NS AN D S PE CIFI CA T IO NS REMAINS WITH CWA STUDIOS WITHOUT PREJUDICE. VISUAL CONTAC T W ITH TH E SE P LANS AND S PE CI F ICATI O NS S HA LL CONSTITUTE PRIMA FACE EVIDENCE OF THE ACCEPTANCE OF T HES E R EST R I CT ION S. C 2 02  C W A S T U DI O S SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/2 NOSING CONTRASTING 2" (MIN.) TO 4" (MAX.) WIDE STRIPE SET STRIPE NO MORE THAN 1" FROM EDGE OF NOSING 7" RISER10-3/4" 3/4" OCCUPANT SENSORS W/ INTEGRAL PHOTO CONTROL CERTIFIED TO COMPLY W/ SECTION 119(D). General Lighting Notes 3'-8 1/4" 3'-8 1/4" WHOLE-BUILDING VENTILATION REQUIREMENTS (FROM ASHRAE 62.2) AT LEAST ONE MECHANICAL VENTILATION SYSTEM IN THE BUILDING MUST BE DESIGNATED FOR USE IN COMPLIANCE WITH THE WHOLE- BUILDING VENTILATION REQUIREMENT. ALTERNATIVELY, THE SUM OF THE RATED AIR FLOWS FROM MULTIPLE FANS CAN BE UTILIZED TO MEET THE REQUIRED WHOLE BUILDING VENTILATION AIRFLOW. THE SYSTEM(S) MUST DELIVER CONTINUOUS VENTILATION AIRFLOW AT A RATE GREATER THAN OR EQUAL TO THE RATE SPECIFIED IN EQUATION 4.1a, AND FAN SONE RATINGS MUST NOT EXCEED 1.0. FOR DWELLING OCCUPANT DENSITIES KNOWN TO BE GREATER THAN (NBR + 1), THE RATE SHALL BE INCREASED BY 7.5 CFM FOR EACH ADDNL PERSON. Whole House Ventilation Calculation FLOOR AREA (SF)NBR OF BR QFAN (cfm) 920 4 50.40 MEP2 MEP Calculations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0220 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 Residential Load Calculations RESIDENTIAL LOAD CALCULATIONS (NEC 220.82) OPTIONAL METHOD NEC 220-30 As an optional method, the STANDARD METHOD, found in ARTICLE 220 of the National Electric Code, may be used 1 GENERAL LIGHTING NOTES SF X 3 VA / SF 920 SF 2760 VA SMALL APPLIANCE LOADS - 220-16 (a) (MIN. 2)1500 VA 3000 VA LAUNDRY LOADS 1500 VA 1500 VA SUBTOTAL 7260 VA 2 COOKING EQPT. LOADS - (NAMEPLATEVALUE) RANGE 5000 VA 5000 VA COOKTOP --VA 0 VA OVEN 0 VA 0 VA SUBTOTAL 5000 VA 3 ELECTRICAL DRYER 220-18 (NAMEPLATE, 5,00 VA MIN) DRYER 5000 VA 5000 VA SUBTOTAL 5000 VA 4 FIXED APPLIANCE LOADS- 230-30(b3) DISHWASHER 0 VA 0 VA DISPOSAL 1140 VA 1140 VA COMPACTOR --VA 0 VA WATER HEATER 0 VA 0 VA HYDROMASSAGE BATHTUB --VA 0 VA MICROWAVE 1500 VA 1500 VA BUILT -IN VACUUM 0 VA 0 VA SUBTOTAL 2640 VA 5 OPTIONAL SUBTOTAL (ADD ALL OF THE ABOVE TOTALS)19900 VA 6 APPLYING DEMAND FACTORS -TABLE 220-30 FIRST 10,000VA @ 100%10,000 VA REMAINING VA @ 40% (SUBTOTAL ABOVE - 10,000) X 40%3960 VA 7 HEATING OR AC LOAD - TABLE 220-30 10000 LARGER OF THE HEATING OR AC LOAD 0 VA 8 POOL PANLE/EQUIPMENT 0 VA 9 OPTIONAL TOTAL VOLT AMPS (ADD TOTAL FROM LINE 6+7)23960 VA 10 MINIMUM SERVICE SIZE (OPTIONAL LOAD TOTAL VA /240 VOLTS) =100 AMPS SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS A.PURPOSE 1.THE FOLLOWING INFORMATION INCLUDES THE BASIC PERMIT APPLICATION REQUIREMENTS FOR A 120/240 VOLT SINGLE PHASE ELECTRICAL SERVICE RATED GREATER THAN 200 AMPERES, BUT NOT OVER 600 AMPERES, INSTALLED ON A SINGLE FAMILY RESIDENTIAL LOT. 2.CAUTION: THIS HANDOUT AND THE NATIONAL ELECTRICAL CODE ARE NOT INTENDED AS DESIGN SPECIFICATIONS NOR INSTRUCTION MANUALS FOR UNTRAINED PERSONS. NEC 90.1(C). THE NATIONAL ELECTRICAL CODE REQUIRES QUALIFIED PERSONS TO DESIGN ELECTRICAL INSTALLATIONS. B.SCOPE 1.IN GENERAL, THE ELECTRICAL EQUIPMENT AND WIRING UNDER THE OWNERSHIP OR RESPONSIBILITY OF THE SERVING ELECTRICAL UTILITY IS NOT REGULATED BY THE NEC. THE APPLICABLE SERVING UTILITY MUST BE CONTACTED FOR ANY ADDITIONAL REQUIREMENTS. 2.UNLESS OTHERWISE NOTED, CODE REFERENCES SHALL BE FROM THE 2005 NATIONAL ELECTRICAL CODE (NFPA 70 - NEC) AS AMENDED BY THE CURRENT CITY ADOPTED ORDINANCE. 3.THIS SHOULD NOT BE CONSIDERED AS A COMPLETE LIST OF CODE REQUIREMENTS. ELECTRICAL INSPECTIONS MUST BE PERFORMED AND ”APPROVED” BEFORE THE WORK IS CONSIDERED COMPLETED BY THE CITY OF SAN LUIS OBISPO. C.DEFINITIONS (NEC ARTICLE 100) 1.QUALIFIED PERSON – ONE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE EQUIPMENT AND THE HAZARDS INVOLVED, I.E. LICENSED ELECTRICAL ENGINEER OR LICENSED ELECTRICAL CONTRACTOR. 2.SERVICE (ELECTRICAL) – THE CONDUCTORS AND EQUIPMENT FOR DELIVERING ELECTRIC ENERGY FROM THE SERVING UTILITY TO THE WIRING SYSTEM OF THE PREMISES SERVED. 3.SERVICE POINT – THE POINT OF CONNECTION BETWEEN THE FACILITIES OF THE SERVING UTILITY AND THE PREMISES WIRING. 4.SERVICE EQUIPMENT – ALSO REFERRED TO AS THE SERVICE ENTRANCE SECTION OR “SES”. THE NECESSARY EQUIPMENT USUALLY CONSISTING OF CIRCUIT BREAKERS OR SWITCHES AND FUSES CONNECTED TO THE LOAD END OF SERVICE CONDUCTORS TO A BUILDING OR OTHER STRUCTURE, OR AN OTHERWISE DESIGNATED AREA, AND INTENDED TO CONSTITUTE THE MAIN CONTROL AND CUTOFF SUPPLY. 5.SUBSERVICE – THE NECESSARY EQUIPMENT CONNECTED TO THE LOAD SIDE OF SERVICE EQUIPMENT 6.SUB-PANEL OR PANEL – A TRADE TERM FOR SUBSERVICE PANELBOARDS OR LOAD CENTERS. 7.PREMISES WIRING – ALL ON-SITE WIRING FROM THE SERVICE POINT TO THE END UTILIZATION OUTLET. 8.FEEDERS – ALL CIRCUIT CONDUCTORS BETWEEN THE SERVICE EQUIPMENT AND THE FINAL OVERCURRENT DEVICE (CIRCUIT BREAKER). D.LOCATION 1.ELECTRICAL UTILITY: WHILE IN THE PLANNING STAGE AND BEFORE PERFORMING ANY WORK, CONTACT THE SERVING ELECTRICAL UTILITY REGARDING THE LOCATION OF THE SERVICE POINT, INSTALLATION REQUIREMENTS, EQUIPMENT TYPE AND REQUIRED CLEARANCES. 2.CLEARANCES IN FRONT OF THE SES AND SUB-PANELS NEC 110.26: (a)A MINIMUM THREE (3) FOOT DEEP LEVEL SPACE IN FRONT OF THE EQUIPMENT. NEC 110.26(A)(1). (b)MINIMUM 2’-6” (30”) WIDE SPACE OR WIDTH OF EQUIPMENT, WHICHEVER IS GREATER. NEC 110.26(A)(2). (c)EQUIPMENT DOORS MUST BE ABLE TO FULLY OPEN 90 DEGREES. NEC 110.26(A)(2). (d)MINIMUM 6’-6” HIGH OR TOP OF THE EQUIPMENT, WHICHEVER IS HIGHER. NEC 110.26(A)(3), 110.26(E). (e)THE ACCESS AND WORK SPACE SHALL NOT BE USED FOR STORAGE. NEC 110.26(B). 3.OUTDOOR/WATER/MOISTURE – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO WATER OR MOISTURE ON A REGULAR BASIS OR IN LARGE QUANTITIES, I.E. WHERE EXPOSED TO LAWN SPRINKLERS OR BELOW A ROOF SCUPPER. NEC 110.26(F). 4.VEHICULAR TRAFFIC – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO DAMAGE BY VEHICULAR TRAFFIC. NEC 110.26(F). 5.CLOTHES CLOSETS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN CLOTHES CLOSETS. NEC 240.24(D). 6.BATHROOMS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN BATHROOMS. NEC 240.24(E). 7.SEPARATE BUILDINGS – REFER TO NEC 225.30 PART B, 250.32, 250.50, 250.104 FOR REQUIRED DISCONNECTING MEANS, GROUNDING, AND BONDING. E.PERMIT AND PLAN REQUIREMENTS 1.SITE (PLOT) PLAN: PROVIDE A SIMPLE SITE PLAN (MINIMUM SCALE 1:40) INDICATING THE LOCATION OF EXISTING BUILDING(S), STRUCTURES, FENCES, POOLS, SPAS, ETC, AND THE LOCATION OR AREA WHERE THE SERVICE AND PANELBOARDS ARE TO BE INSTALLED. REFER TO THE SITE PLAN INCLUDED. 2.SINGLE LINE (FEEDER) DIAGRAM NEC 215.5. – DIAGRAM(S) ARE INCLUDED FOR REVIEW. 3.LOAD CALCULATIONS NEC 220 – PROVIDE ELECTRICAL LOAD CALCULATIONS FOR THE ELECTRICAL SERVICE (SES) AND EACH SUB-SERVICE PANEL TO BE INSTALLED. THE STANDARD OR OPTIONAL METHOD MAY BE USED. A COMPLETED OPTIONAL METHOD IS ATTACHED. EXAMPLES OF BOTH METHODS ARE LOCATED IN APPENDIX D OF THE NEC. F.INSPECTION REQUIREMENTS THE INSPECTION CARD LISTS IN DETAIL THE REQUIRED INSPECTIONS. THE FOLLOWING INSPECTIONS ARE FOR YOUR INFORMATION AND MAY VARY DEPENDING UPON THE INSTALLATION. 1.ROUGH ELECTRICAL 2.FINAL ELECTRIC 3.TEMPORARY ELECTRIC IN PERMANENT POSITION IS AN OPTION THAT CAN ALSO BE USED. AN APPLICATION AND REFUNDABLE DEPOSIT ARE REQUIRED. 4.FOR SERVICE SHUT DOWNS, PLEASE CALL INSPECTION SERVICES TO ARRANGE AN INSPECTION. Electric Panel Requirements / Calculations Basis of Design - Plumbing Calculation EXISTING RESIDENCE. EXISTING WATER PRESSURE AT HOSE BIB CLOSEST TO WATER METER MEASURES 65 PSI. FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 1 1/2"2.5 2.5 LAV SINK 1 1/2"1.5 1.5 KITCHEN SINK 1 1/2"1.5 1.5 COMBINATION TUB / SHOWER 1 1/2"4.0 4.0 DISHWASHER 1 1/2"1.5 1.5 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 17.5 PROPOSED ADU FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 2 1/2"2.5 5.0 LAV SINK 2 1/2"1.5 3.0 KITCHEN SINK 1 1/2"1.5 1.5 COMGO BATH/SHOWER 2 1/2"4.0 8.0 SHOWER 2 1/2"2.0 4.0 DISHWASHER 0 1/2"1.5 0.0 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 20.0 TOTAL (EXISTING RESIDENCE + ADU)37.5 PLUMBING CALCULATION NOTES: 1.THE EXISTING WATER METER IS A 3/4" SIZE WITH A 3/4" BUILDING SUPPLY LINE ON THE CUSTOMER SIDE OF THE METER. USING TABLE 610.3/610.4 FROM THE 2022 CA PLUMBING CODE TO DETERMINE PROPOSED AND EXISTING “WATER SUPPLY FIXTURE UNITS” (WSFU), THE COMBINATION OF EXISTING AND PROPOSED FIXTURE UNITS DOES NOT FALL WITHIN THE ACCEPTABLE RANGE, AND THEREFORE: 2.THE EXISTING 3/4" WATER METER SHALL REMAIN WHILE THE 3/4" BUILDING SUPPLY LINE SHALL BE UPGRADED WITH A 1" BUILDING SUPPLY LINE IN ORDER TO BE ADEQUATE FOR THE PROPOSED ADU. S0.1 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S0.2 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.1 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.2 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.3 Typical Details Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.4 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.1 Foundation Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.2 Second Floor Framing Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.3 Roof Framing Plan = "'-U') � 00a, '<I' "' "' -"' C: ;;.: C0 ·- '<I' Cl < "" C: u ;:;;­..,, • 0 1'--1 o e �-----,- C. I!! .!!! � .i � 00 Jj�---- '-' a, c:: ;;: 0 --'E C.C. "' Q) .lo:: N06J735 Q) > ·;::Cl ,-0""' M c) U") 0""' M C) VJ <'Cl E c..:i C) 0·a5 :I: VJ 0 :c C: 0� :::::s e en0 '- ·-a: Q) C: U) ...J ..c: M C: 0 I.D t'tl --, ,- U) revision: rllV dimipti111 PC CORREC'IDN legal stuff: :::, ..c u. ti 0 2 � 00 � WJ!ldate by 00.15.25 The use of these plans and specifications shall be rn.strlcted ta the use of the orlglrial site for wlllch they were prepared and publication thereof is expressly limtted to such use unless otherwise approved by the architect. Title to these plan3 and specifications remains with cwa studios without prejudice. Visual contact wllll these plans end apeclflcatlons shell constitute pr1ma face evidence of the acceptance of these restrictions c 2020 cwa studios sheet data: SWAjob no: CAD file:drawn by: plot dare: sheet title: 25053.01 JI/ 11.22.25 Structural Details sheet: S3.1 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S3.2 Structural Details Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 2/20/2026 By: Chris Allen, CWA Studios Date: Friday, February 20, 2026 To: City of San Luis Obispo Community Development Department From: Chris Allen, Architect Re: 1st Code Compliance Review Response Letter Permit No. BLDG-2981-2025 New Attached ADU 619 Grove Street San Luis Obispo, CA 93401 CWA job: 197 The following are responses to the 1st plan review for the above referenced project; comments from the 1st plan review are provided below in half-tone for reference, and responses are provided in red font: California Code Check – Building Review 2022 CBC Comments Public Works Permit Review v.1 Emma Laplante elaplant@slocity.org 8057817199 1. Comment: 1. Include the following note under Standard Public Works Notes a. All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Response: Note has been added to the Standard Public Works Notes on sheet T1.0 as requested. See note i. 2. Comment: 2. These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Response: Understood. 3. Comment: 3. Update Standard Public Works Notes to reference the December 2025 City standard Response: Updated. The note now reads “The current adopted standards are dated December 2025”. 4. Comment: 4. A System certification is required from the engineer of record prior to final inspection approvals. The engineer shall certify that the drainage and stormwater system components have been inspected and are in general conformance with the Plan Check Response Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 2/20/2026 By: Chris Allen, CWA Studios drainage report, system design, and the approved plans, including all final elevations, component sizing, detention basins, parking lot detention curb elevations, drainage piping, inlets, weir elevations, and orifices Response: Understood 5. Comment: 5. No project type is checked on the Stormwater Control Plan for Post Construction Requirements, please revise. Response: Multi-Unit Residential is now checked on the SWCP. 6. Comment: 6. Clarify the Proposed drainage strategy a. If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. c. Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain d. Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Response: a) Swales with a 2% slope have been added to prevent watershed from flowing across the property line. This swale diverts water to all three catch basins which will then divert water up to Grover Street through the drainage sump pump. b) All elevations have been updated to allow for the flow of collected watershed to the drainage sump pump, with a minimum of a 1% flowline between grates. Furthermore, we have shown newly proposed topography lines (330’ and 331’) in order to allow this drainage to occur properly. c) Please see newly added sheet reference notes 3/AS1.0 and 28/AS1.1 for clarity as to the area of sidewalk to be restored for the sidewalk underdrain. d) Please see document named “619 Grove – Pump Verification Calculation” for the value guidelines for installation. Please also see newly added spec sheets 1/AS1.2 for pump details. 7. Comment: 7. Revise Plans as follows: a. For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. b. Show existing utility on all sheets with a line, not just a callout. c. Clearly show the drive approach and driveway on the plans. d. There are abbreviations used that are not included in the legend e. A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed f. Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g. The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. h. Show the material of the existing utility. See the attached Utility grid maps for reference. i. Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach Response: a) Dimensions have been added to the site plan, per comment. b) Please refer to sheet legend on sheet AS1.1 for utility lines. Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 2/20/2026 By: Chris Allen, CWA Studios c) Driveway approach and driveway have been shown on the site plan by a paver hatch. Sheet note 5 also indicates the location of this driveway. d) Please refer to the survey legend on sheet SV1.1. Please also refer to newly added “abbreviations” section on sheet AS1.1 for the few abbreviations that are not included in the survey legend. e) Please see new sheet AS1.0 for site demolition notes. Everything is to remain other than the portion of the driveway to be removed to input new utility lines. f) The Utility box pictured in google earth is not for this property. Please refer to the survey on sheet SV1.1 as there is no utility present. g) Note 5/AS1.1 has been revised to read “Existing driveway and flatwork. Portion to be removed for utilities is shown on sheet AS1.0”. Please refer to sheet AS1.0 for area to be removed. h) Utility materials have been added to the site plan, per comment. i) Sheet reference note 26/AS1.1 has been added to call out the existing water meter for the ADU at parcel 1. 8. Comment: 8. The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Response: Understood. Planning v.1 Ethan Estrada ejestrad@slocity.org 8057817576 9. Comment: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Response: Understood. 10. Comment: Trees appear to possibly be impacted by your project proposal and will require review by the City Arborist. An arborist report may be required. Response: Understood. 11. Comment: Provide expanded calculations/confirm the existing lot coverage for this property on the title sheet. Response: Prior lot split, the previous parcel was 6,000 S.F. Please see sheet SV1.1 for split parcels. The current split parcel the ADU resides on is a 3,589 S.F. lot. Therefore, the calculations of lot coverage has been revised to include the existing primary residence footprint only, as we are proposing an ADU that is excluded from lot coverage calculations. Per SLOMC § 17.70.120(B)(5). 12. Comment: Title sheet states one parking space is provided in the driveway. On the site plan, note the location and dimensions of this parking space - keep in mind that parking may not be located in the front yard setback. Response: Parking space along with it’s width has been shown in the existing driveway, not in the front yard setbacks, per comment. 13. Comment: The MEP plan depicts a condenser on the north side of the proposed addition, but the site plan and elevations do not depict this mechanical equipment. Ensure this equipment is depicted consistently throughout the plan set - note the distance between the condenser and the north property line on the site plan. Response: Condenser has been added to all applicable drawings to keep consistency throughout the plans. Dimensions between the condenser and the north property line has also been added per comment. 14. Comment: Per SLOMC 17.70.080, the height of structures on properties with an average cross-parcel slope less than 16% shall be measured from the average natural grade of the portion of the parcel that the proposed structure is to be built on. Adjust the height measurements provided on the elevations so that they are measured from average natural grade. Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 2/20/2026 By: Chris Allen, CWA Studios Response: Average natural grade has been added to the elevation and section drawings, and is marked as being 1’6” below the FF of the first floor. FF elevations have been added to all elevation and section drawings at both the first and second floor as well. 15. Comment: On the elevations, note the direction from which the elevations are being viewed from. Response: Elevation labels have been updated to include the direction in which they are viewed from, per comment. 16. Comment: MEP plan indicates that there will be exterior lighting. Ensure that such lighting is also depicted in the elevations. Response: Please see updated drawing 4/A3.2. Exterior lighting has been added to said drawing and called out using reference note 11/A3.2. 17. Comment: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Response: Please see sheet reference note 1/MEP1 and new note g in the general lighting notes for compliance with SLOMC 17.70.100. All lighting will be night sky compliant, high efficiency, and shall be controlled by occupant sensors. The exact lighting fixtures will be chosen by the property owner and will comply with these specifications. 18. Comment: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Response: Per response to the above comment, please see sheet reference note 1/MEP1 and new note g in the general lighting notes for compliance with SLOMC 17.70.100. All lighting will be night sky compliant, high efficiency, and shall be controlled by occupant sensors. The exact lighting fixtures will be chosen by the property owner, and will comply with these specifications Fees v.1 Vanessa Nichols vnichols@slocity.org 8057817588 19. Comment: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Response: This shall be resolved prior to permit issuance. John Rourke (The property owner) has been in conversation with community development staff on resolution of this item. Final determination on how to proceed is pending and will be provided once it is available. 20. Comment: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. Response: Plumbing calculation has been added to sheet MEP2 per comment. Upon conclusion of the calculation, it is found that the existing ¾ water meter and service line will need to be upgraded to a 1” meter with a 1” building supply to comply with CPC table 610.4. 21. Comment: #3 Final fees pending response to comments and other department reviews. Response: Understood. Addressing v.1 Vanessa Nichols vnichols@slocity.org 8057817588 22. Comment: #1 Address assigned to new ADU is 619 A Grove Street. Please update all plan sheets to reflect the newly assigned address. Response: Plans have been updated to reflect the newly assigned address of 619 A Grove in all applicable locations on the plans, Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 2/20/2026 By: Chris Allen, CWA Studios per comment. Code Enforcement v.1 Steve Sheets ssheeats@slocity.org 23. Comment: CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Response: This shall be resolved prior to permit issuance. John Rourke (The property owner) has been in conversation with community development staff on resolution of this item. Final determination on how to proceed is pending and will be provided once it is available. Building v.1 Yazneed Hassan yazneedh@tncservices.com 5627338030 24. Comment: A1. Sheet T1.0: Revise occupancy to be R-3 Response: Occupancy has been revised to be R-3, under Project data on sheet T1.0. 25. Comment: A2. Sheet T1.0: Revise sheet S3.3 on the index to be S3.2 Response: Sheet S3.3 has been changed to S3.2 in the index on sheet T1.0. 26. Comment: A3. Sheet A2.1: Revise door 3 for the bedroom and the bathroom on the first floor to have a width of 3’ to provide 32” clear width for per Aging-in-place requirements. Response: Please see newly added door #4 on the door schedule calling out a 3’ interior door for both the bedroom and bathroom on the ground floor. 27. Comment: A4. Sheet A2.1: Detail A/A2.1 referenced on plans does not appear to be provided. Response: Apologies. Detail A/A2.1 was meant to read 7/A5.2 to call out the expansion joint at the seismic gap provided between the proposed ADU and the existing residence. 28. Comment: A5. Sheet A5.2: fire rated wall details are not coordinated; sections show gypsum board on the exterior side and fire rated wall details show stucco on the exterior side of the wall. Please provide an approved fire-rated construction detail with basis of approval (i.e., UL design, G.A. file #) for the rated wall and cross reference onto the plans. CRC Table R302.1(1). Response: Seismic gap section drawings and fire rated wall assembly details have been coordinated to show the same exterior finishes, per comment. Basis of approval for the fire rated wall assembly has also been added to detail 6/A5.2. 29. Comment: A6. Sheet A3.2: Provide construction details for the exterior stairs in accordance with CRC 311. Response: Please see newly added sheet A5.4 for stair details in compliance with CRC 311. 30. Comment: A7. Sheet A4.1: Note 4 refers to detail A and B that appear to be missing. Response: Sheet reference note 4/A4.1 has been updated to correctly callout the seismic details on sheet A5.2. 31. Comment: A8. Sheet MEP1: Provide carbon monoxide alarm in the area leading to bedroom 202. Response: Carbon monoxide alarm on the second floor Has been relocated to sit at the top of the stairs to be used as the alarm in the area leading to all three bedrooms, including bedroom 202. 32. Comment: M1. Sheet MEP1: Show the location of the bathroom and kitchen exhaust duct termination. Air ducts shall exhaust 3’- 0” from property line and 3’-0” from openings into the building. CMC 504.5. Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 2/20/2026 By: Chris Allen, CWA Studios Response: Please see newly added note 14/MEP1 for exhaust duct termination. Dimensions have also been added to ensure ducting termination is more than 3’ from the nearest building opening, per CMC 504.5. 33. Comment: E1. Sheet MEP1: Specify exterior receptacle outlets to be provided with waterproofing cover. Response: All exterior outlets are now labeled as WP/GFI to indicate waterproofing. 34. Comment: E2. Sheet MEP1: Show the location and size of electrical panel. Response: Apologies, the electrical panel was not called out in the previous submittal. Please see sheet reference note 2/MEP1 and it’s respective callout on drawing 1/MEP1 for panel sizing and location. 35. Comment: P1. Sheet MEP1: Show the size and location of sewer lateral. Response: Please see revised reference note 25/A1.1. 36. Comment: G1. Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Response: Sheets T1.1 and T1.2 have been updated with the July 2024 supplement, per comment. 37. Comment: T1. Sheet T1.0: List all HERS inspection features and special features required. Please coordinate with the Energy Report. Response: “HERS Feature Summary” has been added to sheet T1.0, per comment. 38. Comment: T2. Sheet A4.1: In the cross section of the building identify the insulation with the respective R-values at the walls, attic/ceiling, floors, and etc. per the Title-24 Certificate of Compliance Form. Response: Insulation R-values have been added to the section drawings on sheet A4.1 in accordance with the energy documents. Please see newly added sheet reference notes 5/A4.1 and 6/A4.1 for reference. 39. Comment: S1. Sheet A1.3: Provide calculations and details. Guards and handrails shall be designed to resist a load of 200 psf applied in any direction at the top and to transfer this load through the support structure. CRC R301.5 Response: Stair details have been added to sheet S3.1. Please refer to this sheet for reference. 40. Comment: S2. Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Response: There is no geotechnical report needed for this project, as ADU has a footprint of less than 500 SF. 41. Comment: S3. Sheet S2.1: Detail 1/S3.1 is referenced for continuous footing along gridline 19Y which does not appear to be accurate. Civil and elevation sheets show ADU to be built on sloped land. Please provide accurate details and calculations. Response: Per structural engineer, ““Detail 1/S3.1 allows for a deepened footing with additional reinforcement as needed at the deeper parts.” 42. Comment: S4. Sheet S2.2: The ridge board shall have bigger thickness than the rafters connected to it. Revise rafters to be 2x10 or ridge board to be 2x14. Response: Per structural engineer, “If the ridge in question was a ridge board it would have to be deeper than the vertical cut on the rafters. However, this is a ridge beam and does not.” 43. Comment: S5. Sheet S2.2: Provide framing and foundation details for exterior stairs. Response: Sheets S2.1 and S3.1 have been updated to provide framing and foundation details for the new exterior stairs. Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 2/20/2026 By: Chris Allen, CWA Studios 44. Comment: S6. Sheet S2.1: Specify the header size above each exterior opening. Response: Per structural engineer, “There is a note referring to our header schedule on each plan sheet”. Arborist v.1 Walter Gault wgault@slocity.org 8057817578 45. Comment: Possible impact on trees - Ethan Response: Understood. END Stormwater Control Plan for Post Construction Requirements Exhibit 4 Application Submittal Where directions state “Done” that means no additional information or forms below that point needs to be filled out or furnished. See Exhibits for Watershed Management Zones, Basins, & Urban Sustainability Areas Use “n/a” where information requested is not applicable. If you are unsure regarding how to fill out any of the information, please come in and request assistance from a staff person. Project Information Step 1 Applicant Name: Application No: Project Name: Location Address: Location APN: Site Zoning: Project Type:  Commercial Detached Single Family Residential Industrial Multi-unit Residential Mixed Use Public Project Phase: Project Description: Total Project Site Area = (a) Total New Impervious Surface Area = (b) Total Replaced Impervious Surface Area = (c) Total Existing Impervious Area = (d) Total Impervious Area of Completed Project = (e) Net Impervious Area: (a+b) – (c-d) = OR where (c-d) is a negative number: (a+b) = Your project is NOT subject to Post Construction Requirements if… Step 2  Area (a+b) of project is < 2,500 square feet – Done OR  Area (a+b) of project is > 2,500 square feet, and is a project type listed below ( type) – Done  Road & parking surface repair – slurry & fog & crack seal, pothole & spot patching, overlay & resurfacing & other damage repair with no expansion  Road & parking shoulder grading  Road & parking cleaning, repairing, maintaining, reshaping, regarding drainage systems  Sidewalk & bike path / lane project – no other impervious surface created and runoff is directed to vegetated area  Curb & gutter improvement or replacement – no other impervious created  Underground utility project – surface replaced in kind  Utility vaults – Ex: lift stations, backflows  Fuel storage – above ground with spill containment  Photovoltaic systems – on existing impervious surface, over pervious surface with vegetated cover, buffer strip at the most down gradient row of panels  Second story – no increase in building footprint  Decks & stairs & walkways – raised with space below for drainage  Temporary structures – in place less than 6 months  Trails and pathways, where no other impervious surfaces are replaced or created, and built to direct stormwater runoff to adjacent vegetated areas. Form revised: July 12, 2016 Chris Allen New attached ADU 619 grove Street, San Luis Obispo, CA 93405 001-056-052 R-1 New Construction This project consists of the construction of a new 2-story 920 S.F. attached accessory dwelling unit at the rear of an existing S.F.R. 3,589 S.F. 646 S.F. 230 S.F. 1,704 S.F. 2,350 S.F. 876 S.F. 4 4 DESCRIPTION THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. SITE INFORMATION EXISTING BUILDING INFORMATION JURISDICTION ZONING APN STREET ADDRESS GROSS LOT SIZE BUILDING AREAS PROPOSED INFORMATION TWONUMBER OF STORIES R-3 (RESIDENTIAL)OCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE SPRINKLERED CLASS A ROOFINGROOF RATING TWO STORYNUMBER OF STORIES R-3 (RESIDENTIAL) / UOCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSEDFIRE SPRINKLERS CITY OF SAN LUIS OBISPO LOW DENSITY RESIDENTIAL (R-1) 001-056-052 619 A GROVE STREET, SAN LUIS OBISPO, CA 93401 0.08 ACRES (3,589 SF) CLASS AROOF RATING 25 FEET ALLOWEDMAXIMUM HEIGHT PROPERTY IS NOT LOCATED WITHIN A HIGH FIRE RISK AREA OR FLOOD PLAIN AREAHAZARDS LOT COVERAGE MAX 40% = 3,589 X 0.4 = 1,436 SF. PROPOSED = 862 SF. 862 / 3,589 = 24% (ADU EXCLUDED FROM LOT COVERAGE CALCULATIONS PER MC § 17.70.120(B)(5)) 1 SPACE PROVIDED IN DRIVEWAY PER PREVIOUS LOT SPLITPARKING LEGAL DESCRIPTION CY SLO PM 84/92-93 PAR 2 1 SPACE PROVIDED IN DRIVEWAYPARKING NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSED T1.0 Title Sheet, General Notes + Project Data Sheet Index OWNER Project Directory SOILS ARCHITECT CWA STUDIOS 1668 SYDNEY STREET SAN LUIS OBISPO. CA 93401 CONTACT: CHRIS ALLEN, AIA. 805 286 5186 Drawing Log SET ISSUE DATE REVISION Project Notes ENERGY CARSTAIRS ENERGY CALCULATIONS 2238 BAYVIEW HEIGHTS DRIVE, SUITE E LOS OSOS, CA 93402 CONTACT: TIM CARSTAIRS. 805 904 9048 Project Data T1.1 INDEX, DATA + NOTES STRUCTURAL Calgreen Mandatory Measures 1.PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL SHALL MANAGE STORMWATER DURING CONSTRUCTION. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. CALGREEN 4.106.2.2 2.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED AND SHALL COMPLY WITH THE PLUMBING FIXTURE AND FITTINGS SCHEDULE ON THIS SHEET. CALGREEN 4.303.3.1 3.AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1 - CONTROLLERS SHALL BE WEATHER- OR SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANT WATERING NEEDS AS WEATHER OR SOIL CONDITIONS CHANGE. 2 - WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). CALGREEN 4.304.1 4.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE CLOSED WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY TO PREVENT PASSAGE OF RODENTS. CALGREEN 4.406.1. 5.RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 60% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4; OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. CALGREEN 4.408.1 6.DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION PER CALGREEN 4.504.1. 7.ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS PER CALGREEN 4.504.2.1. 8.PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.2.2. 9.AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS PER CALGREEN 4.504.2.3. 10.DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED PER CALGREEN 4.504.2.4. 11.CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.3. 12.EIGHTY (80) PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERINGINSTITUTE (RFCI) FLOORSCORE PROGRAM PER CALGREEN 4.504.4. 13.PARTICLEBOARD, MEDIUM FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR OR EXTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS PER CALGREEN 4.504.5. 14.VAPOR RETARDER AND CAPILLARY BREAK OF 4” THICK BASE OF ½” OR LARGER CLEAN AGGREGATE SHALL BE INSTALLED AT SLAB ON GRADE FOUNDATIONS PER CALGREEN 4.505.2. 15.MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING SHALL BE CHECKED BEFORE ENCLOSURE PER CALGREEN 4.505.3. 16.BATHROOM EXHAUST FANS SHALL BE DUCTED TO TERMINATE OUTSIDE AND BE PROVIDED IN EVERY BATHROOM PER CALGREEN 4.506.1. 17.WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED LOUVERS OR COVERS WHICH CLOSE WHEN THE FAN IS OFF. COVERS OR LOUVERS SHALL HAVE A MINIMUM INSULATION VALUE OF R-4.2 PER CALGREEN 4.507.1. 18.PER CALGREEN 4.507.2 DUCT SYSTEMS ARE SIZED, DESIGNED, AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS: 1. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ACCA (MANUAL J) OR EQUIVALENT. 2. SIZE DUCT SYSTEMS ACCORDING TO ACCA 26-D (MANUAL D) OR EQUIVALENT. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S (MANUAL S) OR EQUIVALENT. 19.OPERATION + MAINTENANCE MANUAL TO BE SUPPLIED AT FINAL INSPECTION. 20.MANAGE STORMWATER PER CALGREEN CODE REQUIREMENTS. 4106.2 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 25.1222 Deferred Submittals / Separate Permits 1.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDER-DRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. SURVEY MBS LAND SURVEYS 3559 SOUTH HIGUERA ST. SAN LUIS OBISPO CA 93401 CONTACT: MICHAEL B STANTON 805 594 1960 ARCHITECTURAL1.ALL WORK SHALL BE IN CONFORMANCE WITH THE 2022 EDITIONS OF THE CALIFORNIA BUILDING CODES 2.ANY/ALL DEFERRED SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT AND/OR PROJECT ENGINEER PRIOR TO SUBMISSION TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL. 3.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. 4.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. 5.THE PUBLIC IMPROVEMENTS SHALL BE SUBSTANTIALLY COMPLETE TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR PRIOR TO FINAL INSPECTION APPROVALS AND/OR OCCUPANCY OF ANY BUILDING. 6.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER AND SIDEWALK OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 7.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 805 781 7554 WITH AT LEAST A 48 HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. 8.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. 9.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. 10.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED DURING ALL CONSTRUCTION AND GROUND DISTURBING ACTIVITIES PER THE CITY OF SAN LUIS OBISPO 11.TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN PERMANENT IMPROVEMENTS, PLANTINGS AND FACILITIES ARE IN PLACE. TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION APPROVALS. 12.THE EXISTING SEWER LATERAL SHALL BE TELEVISED AND APPROVED FOR REUSE OR SHALL BE REPAIRED/REPLACED. THE INSPECTION SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE UTILITIES DEPARTMENT PRIOR TO ISSUANCE OF A BUILDING PERMIT. 13.ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE VERTICAL AND GREATER AND AREAS USED TO CONVEY CONCENTRATED DRAINAGE SHALL BE PREPARED AND MAINTAINED TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED NO LATER THAN 30 DAYS PRIOR TO A REQUEST FOR FINAL INSPECTION APPROVAL. 14.REMODELING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS A VIOLATION OF CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELERS AND PAINTERS ARE REQUIRED TO USE "LEAD-SAFE" WORK PRACTICES PURSUANT TO TITLE 17, CA CODE OF REGULATIONS SECTION 36050. 15.PRIOR TO ANY DEMOLITION OR GRADING THE CONTRACTOR SHALL PROTECT ANY TREES ADJACENT TO THE WORK ZONE. 16.THE MANDATORY PROVISIONS OF CALGREEN CHAPTER 4 SHALL BE APPLIED TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. CALGREEN 301.1.1 17.ON AND AFTER JANUARY 1, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. CALGREEN 301.1.1 18.APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER ORDINANCE OR LAW. CBC 105.4 19.THIS PROJECT IS LOCATED IN THE HIGH FIRE SEVERITY ZONE AS PER CITY OF SAN LUIS OBISPO California Building Code Chapter 7A Req. THE CITY OF SAN LUIS OBSIPO IS CONSIDERED A "COMMUNITY AT RISK" DUE TO THE THREAT OF WILDFIRE IMPACTING THE URBAN COMMUNITY. THE CITY SHALL CONTINUE TO ENHANCE THE FIRE SAFETY AND CONSTRUCTION CODES FOR NEW BUILDINGS IN ORDER TO REDUCE THE RISK OF URBAN FIRES THAT MAY RESULT FROM WILDFIRES. NEW BUILDINGS CITYWIDE SHALL INCORPORATE THE FOLLOWING CONSTRUCTION METHODS AND MATERIALS: IGNITION RESISTANT EXTERIOR WALL COVERINGS; FIRE SPRINKLER PROTECTION IN ATTIC AREAS (AT LEAST ONE "PILOT HEAD"); EMBER RESISTANT VENT SYSTEMS FOR ATTICS AND UNDER FLOOR AREAS, PROTECTED EAVES AS IDENTIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7A. CRC R337.1.2. STORK, WOLFE & ASSOCIATES 555 CHORRO ST. SUITE A1 SAN LUIS OBISPO, CA 93401 CONTACT: JUSTIN WOLFE, PE. PH: 805 548 8604 STRUCTURAL AS1.1 ARCHITECTURAL SITE PLAN T1.2 A3.1 EXISTING BUILDING ELEVATIONS A5.2 ARCHITECTURAL DETAILS S0.1 STRUCTURAL GENERAL NOTES S1.4 TYPICAL DETAILS S1.2 TYPICAL DETAILS S2.2 S2.3 ROOF FRAMING PLAN SECOND FLOOR FRAMING PLAN S0.2 STRUCTURAL GENERAL NOTES S1.1 TYPICAL DETAILS A4.1 PROPOSED BUILDING SECTIONS S1.3 TYPICAL DETAILS S2.1 FOUNDATION PLAN S3.1 STRUCTURAL DETAILS CALGREEN MANDATORY MEASURES G r o v e S t r e e t R e s i d e n t i a l A d d i t i o n 6 1 9 A G r o v e S t r e e t , S a n L u i s O b i s p o , C A 9 3 4 0 1 A5.1 ARCHITECTURAL DETAILS N/A T1.3 CALGREEN MANDATORY MEASURES Vicinity Map S3.2 STRUCTURAL DETAILS Construction Documents for SV1.1 EXISTING TOPOGRAPHIC SURVEY PROJECT LOCATION CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 BUILDING AREAS (EXISTING) (PROPOSED) PRIMARY RESIDENCE (EXISTING) 1,287 SQ. FT. PROPOSED ADU GROUND FLOOR 490 SQ. FT. SECOND FLOOR 430 SQ. FT. TOTAL (INCLUDING EXISTING RESIDENCE) 2,292 SQ. FT. N/ASOILS REPORT JOHN ROURKE 163 SERRANO HEIGHTS DRIVE SAN LUIS OBISPO. CA 93405 CONTACT: JOHN ROURKE. PH: 805 440 4973 A2.1 PROPOSED FLOOR PLANS + ROOF PLAN A3.2 PROPOSED BUILDING ELEVATIONS AS1.2 ARCHITECTURAL SITE DETAILS Standard Public Works Notes a.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. (THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. b.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY, WITHIN CITY EASEMENTS, OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. c.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK, OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. d.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST A 48-HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. e.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. f.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. g.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. h.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. i.ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT LESS THAN 2% SHALL HAVE FINAL GRADIENTS CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER PRIOR TO FINAL INSPECTION APPROVALS. Stormwater Compliance Summary THE PROJECT IS NOT A REGULATED PROJECT SUBJECT TO REGIONAL WATER QUALITY CONTROL BOARD RESOLUTION R3-2013-0032 “POST CONSTRUCTION STORMWATER MANAGEMENT REQUIREMENTS FOR DEVELOPMENT PROJECTS IN THE CENTRAL COAST REGION” BASED ON THE FOLLOWING: ☒PROJECT DOES NOT CREATE AND/OR REPLACE 2,500 SQUARE FEET OR MORE OF IMPERVIOUS AREA ☐PROJECT TYPE IS LISTED IN SECTION B.1.B (STATE WHICH): Applicable Governing Codes: 2022 2022 2022 CALIFORNIA BUILDING CODE, VOLUMES 1+2 CALIFORNIA ELECTRIC CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA GREEN BUILDING CODE CALIFORNIA FIRE CODE CALIFORNIA ENERGY CODE CALIFORNIA RESIDENTIAL CODE 2022 2022 2022 2022 2022 SAN LUIS OBISPO MUNICIPAL CODE NOT TO SCALE T1.4 ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS T1.0 A5.3 FIRESTOPPING DETAILS SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0220 HERS Feature Summary THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY A CERTIFIED HERS RATER AS A CONDITION FOR MEETING THE MODELED ENERGY PERFORMANCE FOR THIS COMPUTER ANALYSIS. ADDITIONAL DETAIL IS PROVIDED IN THE BUILDING TABLES ON SHEET T1.3. REGISTERED CF2RS AND CF3RS ARE REQUIRED TO BE COMPLETED IN THE HERS REGISTRY •INDOOR AIR QUALITY VENTILATION •KITCHEN RANGE HOOD •VERIFIED EER/EER2 •VERIFIED SEER/SEER2 •VERIFIED REFRIGERANT CHARGE •AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7) •VERIFIED HSPF •VERIFIED HEAT PUMP RATED HEATING CAPACITY •WALL-MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 FT2 (SC3.4.5) • DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONDITIONED SPACE (SC3.1.4.1.8) A5.4 ARCHITECTURAL DETAILS AS1.0 SITE DEMO / GRADING PLAN MEP2 ELECTRICAL FLOOR PLANS + NOTES ARCHITECTURAL MEP3 MEP CALCULATIONS EXTERIOR LIGHTING COMPLIANCE MEP1 T1.1 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 Y ALL Y Y ALL Y CONT CONT N/A N/A N/A N/A N/A N/A N/A N/A Y ALL Y OWNER Y ALL Y CONT Y OWNER Y CONT Y CONT Y CONT Y OWNER Y OWNER N/A N/A N/A T1.2 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 N/A N/A Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y OWNER Y CONT Y CONT Y CONT T1.3 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 T1.4 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SV1.1 Existing Topographic Survey TOPOGRAPHIC MAPJOHN pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 Sheet Reference Notes 1.EXISTING BRICK PAVERS TO BE REMOVED 1 1 1 1 1 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 AS1.0 Site Demo / Grading Plan Sheet Reference Notes 1.PORTION OF DRIVEWAY TO BE REMOVED FOR NEW UTILITIES, SHADED. PAVERS WILL BE PUT BACK IN PLACE ONCE WORK IS COMPLETE 2.NEW TOPOGRAPHY LINES THROUGH SITE GRADING TO ALLOW FOR DRAINAGE TO FLOW TOWARDS THE SUMP PUMP VIA A 1% SLOPE. 3.AREA OF SIDEWALK TO BE REMOVED TO PLACE SIDEWALK UNDER-DRAIN, AND TO BE RESTORED FROM SCORE MARK TO SCORE MARK AFTER DRAIN INSTALLATION IS COMPLETE. 4.DRIVEWAY APPROACH TO BE CONVERTED 331.1' FG. 331.5' FG. 331.6' TG. 331.4' TG. 331.7' FG. 330.0' INV. 331.0' TG. 329.0' INV. 329.0' INV.330331330SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD SDSD SD SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSC.O. C.O. WM 23'-0"12'-0" 35'-0" 70'-0" RIGHT-OF-WAY 22 1 5% SLO P E 2% SLOPE 2% SLOPE3 4 168420 Architectural Site Plan11/8" = 1'-0" MINIMUM OF ONE NEW TREE FOR EACH TREE AUTHORIZED TO BE REMOVED WHEN PLANTED ON THE SAME PROPERTY (ON SITE) OR TWO NEW TREES FOR EACH TREE AUTHORIZED TO BE REMOVED WHEN PLANTED ON A DIFFERENT PROPERTY OR WITHIN THE PUBLIC RIGHT-OF-WAY (OFF SITE). COMPENSATORY PLANTINGS SHALL BE OF A SIZE CONSISTENT WITH CITY ENGINEERING STANDARDS AS SET FORTH IN THE CITY OF SAN LUIS OBISPO MUNICIPAL CODE 12.24.090. DRIP IRRIGATION WILL SERVE THE REPLANTED TREES, USING 1.0 GHP EMITTERS. ALL IRRIGATION WORK SHALL MEET THE REQUIREMENTS OF APPLICABLE STATE AND LOCAL CODES. 311 32 Architectural Site Details Liberty Grinder Pump Specification1N.T.S. DensGlass Installation Guide - Fastening and Framing N.T.S.3 Sidewalk Underdrain N.T.S.2 AS1.2 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 MAX). #4 REBAR @ 12" O.C.2" FROM RAINWATER SUMP PUMP, REFER TO SITE PLAN 12" CATCH BASIN, NDS OR EQUAL. 1/4 BEND. Proposed Floor Plans, Roof Plan, and Schedules CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 0 1 2 84 1/4" = 1'-0" Proposed First Floor Plan1 0 1 2 84 1/4" = 1'-0" Proposed Second Floor Plan2 A2.1 Floor Plan Reference Notes 1.HARDWOOD VANITY CABINETS 20" DEEP WITH FINISH COUNTER HEIGHT OF +36" A.F.F. . 2.QUARTZITE COUNTERTOP. USE 2CM SLAB THICKNESS AS DROP EDGE CEASARSTONE, OR EQUAL. COLOR TO BE SELECTED BY OWNER. 3.SINK: KOHLER, OR EQUAL. FAUCET: HANSGROHE BATHROOM FAUCET, OR EQUAL. 4.MIRROR FROM TOP OF COUNTER TO CEILING OR PER OWNERS SELECTION. 5.SHOWER HEAD: KOHLER, OR EQUAL. CONTROLS: THERMOSTATIC/PRESSURE BALANCE MIXING VALVE TO PROVIDE SCALD + THERMAL SHOCK PROTECTION. 6.66" PRE-FABRICATED FIBERGLASS TUB. TOP @ 18" A.F.F.. 7.TOILET: LOW-FLOW AMERICAN STANDARD CADET 3, OR EQUAL. 8.GUARDRAILS; SHALL HAVE A MINIMUM HEIGHT OF 42". INTERMEDIATE RAILINGS SHALL BE SPACED AT A MAXIMUM OF 3-3/4". HANDRAILS; SHALL HAVE A HEIGHT OF 36" WHERE LOCATED IN STAIRWAYS. A MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT IS 31-1/2" WHERE A HANDRAIL IS INSTALLED ON ONE SIDE OF THE STAIRWAY, AND 27" WHERE HANDRAILS ARE INSTALLED ON BOTH SIDES. 9.STAIRS, 7-3/4" MAX RISER / 10" MIN. TREAD DEPTH. TO BE IN COMPLIANCE WITH CRC R311.7. 10.NEW FIXTURES PER CALGREEN MANDATORY MEASURES. 11.INFILL WINDOWS IN EXISTING RESIDENCE WITH OPAQUE WALL. 12.6" SEISMIC GAP BETWEEN EXISTING RESIDENCE AND PROPOSED ADU AS SHOWN, REFERENCE DETAIL 7 ON SHEET A5.2 FOR MORE DETAIL. 0 1 2 84 1/4" = 1'-0" Proposed Roof Plan3 Legend X NEW 2X4 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS NEW 2X6 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS DOOR / WINDOW CALLOUTS; SEE DOOR & WINDOW SCHEDULE THIS SHEET FOR DETAILS 1-HR RATED ASSEMBLY BETWEEN NEW ACCESSORY DWELLING UNIT AND EXISTING RESIDENCE. NEW RATED WALL SHALL EXTEND FROM CONCRETE SLAB TO BOTTOM OF PROPOSED ROOF SHEATHING IN ALL LOCATIONS. REFERENCE DETAIL 4 & 6 ON A5.2 FOR ADDITIONAL INFORMATION. WINDOW AND DOOR NOTES: 1.ALL EXTERIOR DOORS SHALL BE WEATHER-STRIPPED AND SHALL FEATURE WATER-RESISTANT THRESHOLDS AND/OR DOOR BOTTOMS 2.THRESHOLDS SHALL BE 3/4" MAXIMUM AT SLIDERS AND 1/2" MAXIMUM FOR OTHER DOORS. 3.TEMPERED GLAZING SHALL BE PROVIDED WHERE INDICATED IN THESE PLANS IN ACCORDANCE WITH THE REQUIREMENTS FOR HAZARDOUS LOCATIONS [CBC 2406.3] 4.LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-½" LOWER THAN TOP OF THRESHOLD. (THE LANDING / FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 7-¾" BELOW TOP OF THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR.) [R311.3.1] 5.PROVIDE LOCKSETS AND DEADBOLTS ON ALL EXTERIOR HINGED DOORS. 6.WINDOWS THAT SERVE AS A REQUIRED MEANS OF EGRESS ARE DENOTED ON THE EXTERIOR ELEVATIONS. EGRESS WINDOWS SHALL HAVE A MAX DIMENSION OF 44" TO THE OPENING ABOVE THE FLOOR, PROVIDE 5.7 SQUARE FEET OF CLEAR EGRESS AREA WITH 24" MIN. HEIGHT AND 20" MIN. WIDTH. Window Schedule WIDTH HEIGHT FRAMETYPE A 4'-0" B HEADER +80" Door Schedule WIDTH HEIGHT FRAME PANELTYPE 6'-8"EXTERIOR - HINGED 2 1 # # VINYL4'-0" GLAZED, TEMPEREDWOOD 3'-8"2'-6" +80" 3'-0" 6'-8" INTERIOR - HINGED 3 S.C. SLABWOOD 2'-8" VINYLSLIDING SLIDING INTERIOR - HINGED A CLASS "A" COMP SHINGLE ROOFING TO MATCH EXISTING. PRODUCT SHALL MEET OR EXCEED UL 790 (CLASS A FIRE RESISTANCE STANDARD). A DRIP EDGE SHALL BE PROVIDED AT EAVES AND RAKE EDGES OF SHINGLE ROOFS PER R905.2.8.5. 3.METAL GUTTER AND DOWNSPOUT PROVIDED, AS REQUIRED. LOWER ROOF DRAINS TO CONNECT TO LEADERS DOWN TO SITE DRAINAGE CONNECTIONS. INLET SHALL BE EQUIPPED WITH A LEAF STRAINER TO PROHIBIT DEBRIS FROM ENTERING THE DOWNSPOUT. 1 1 2 2 2 3 3 1'-7"1'-10 1/2"1'-10 1/2"1'-10 1/2"1'-8"1'-8"3'-2" 3'-2"3'-1"6" SEISMICGAPLIVING ROOM 101 KITCHEN 102BATH 105 BEDROOM 106 LAUNDRY 104 HALL 103 BATH 203 BEDROOM 202 HALL 201 1/A4.11/A4.1BEDROOM 204 BEDROOM 205 6'-8"4 3'-0"INTERIOR - HINGED S.C. SLABWOOD A3.1 Existing Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S. 4 D 3/4 D 3/4 D 4 D 1 A 2 F 2 F 6 C 8 - 10 - A3.2 Proposed Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S. FIRST LEVEL (0'-0") (FF = 333') F.F. @ SECOND LEVEL (9'-0")(FF = 342') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') A4.1 Proposed Building Sections CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S. -0") TOP PLATE OF WALL (17'-0") WINDOW & DOOR HEADERS (15'-8") AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') Architectural Details CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. Penetrations and Firestopping NOT TO SCALE Bi-Pass Door - Head and Jamb Typical Jamb, Head, and Sill Installation @ Exterior Windows + Doors 3" = 1'-0" 5 1 Through Wall Penetrations and Firestopping N.T.S.4 SYSTEM NO. W-L-1054NOT TO SCALE 8 3" = 1'-0" 6 A5.2 EXTERIOR 7/8" 3-COAT CEMENTIOUS PLASTER SIDING OVER MIN. TWO LAYERS GRADE D BUILDING PAPER. Firestopping Details A5.3 CAD FILE CWA JOB NO DRAWN BY PLOT DATE 2020 1 sheet: sheet data: revision: sheet title: REV DESCRIPTION BYISSUE DATE SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1 SYDNEY STREET, SLO, CA 3401 EMAIL CWA.ARCH GMAIL.COM TELEPHONE 0.2.1 AIA, LEED AP, C-31 CHRISTOPHER W. ALLEN C31 EXP. 0.30.2LIC E N S E D A RCHITE C TS TATE OF C A L I F O R N IA12/22/2 2.030 legal stuff: THE USE OF THES E PLANS AND SPECIFICAT IONS SHALL BE RESTRICTED TO THE USE OF THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE UNLESS OTHERWISE APPROVED BY THE A RC HITECT. TITL E TO T HES E P LA NS AN D S PE CIFI CA T IO NS REMAINS WITH CWA STUDIOS WITHOUT PREJUDICE. VISUAL CONTAC T W ITH TH E SE P LANS AND S PE CI F ICATI O NS S HA LL CONSTITUTE PRIMA FACE EVIDENCE OF THE ACCEPTANCE OF T HES E R EST R I CT ION S. C 2 02  C W A S T U DI O S SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/2 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/0/2 NOSING CONTRASTING 2" (MIN.) TO 4" (MAX.) WIDE STRIPE SET STRIPE NO MORE THAN 1" FROM EDGE OF NOSING 7" RISER10-3/4" 3/4" OCCUPANT SENSORS W/ INTEGRAL PHOTO CONTROL CERTIFIED TO COMPLY W/ SECTION 119(D). General Lighting Notes 3'-8 1/4" 3'-8 1/4" WHOLE-BUILDING VENTILATION REQUIREMENTS (FROM ASHRAE 62.2) AT LEAST ONE MECHANICAL VENTILATION SYSTEM IN THE BUILDING MUST BE DESIGNATED FOR USE IN COMPLIANCE WITH THE WHOLE- BUILDING VENTILATION REQUIREMENT. ALTERNATIVELY, THE SUM OF THE RATED AIR FLOWS FROM MULTIPLE FANS CAN BE UTILIZED TO MEET THE REQUIRED WHOLE BUILDING VENTILATION AIRFLOW. THE SYSTEM(S) MUST DELIVER CONTINUOUS VENTILATION AIRFLOW AT A RATE GREATER THAN OR EQUAL TO THE RATE SPECIFIED IN EQUATION 4.1a, AND FAN SONE RATINGS MUST NOT EXCEED 1.0. FOR DWELLING OCCUPANT DENSITIES KNOWN TO BE GREATER THAN (NBR + 1), THE RATE SHALL BE INCREASED BY 7.5 CFM FOR EACH ADDNL PERSON. Whole House Ventilation Calculation FLOOR AREA (SF)NBR OF BR QFAN (cfm) 920 4 50.40 MEP2 MEP Calculations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 Residential Load Calculations RESIDENTIAL LOAD CALCULATIONS (NEC 220.82) OPTIONAL METHOD NEC 220-30 As an optional method, the STANDARD METHOD, found in ARTICLE 220 of the National Electric Code, may be used 1 GENERAL LIGHTING NOTES SF X 3 VA / SF 920 SF 2760 VA SMALL APPLIANCE LOADS - 220-16 (a) (MIN. 2)1500 VA 3000 VA LAUNDRY LOADS 1500 VA 1500 VA SUBTOTAL 7260 VA 2 COOKING EQPT. LOADS - (NAMEPLATEVALUE) RANGE 5000 VA 5000 VA COOKTOP --VA 0 VA OVEN 0 VA 0 VA SUBTOTAL 5000 VA 3 ELECTRICAL DRYER 220-18 (NAMEPLATE, 5,00 VA MIN) DRYER 5000 VA 5000 VA SUBTOTAL 5000 VA 4 FIXED APPLIANCE LOADS- 230-30(b3) DISHWASHER 0 VA 0 VA DISPOSAL 1140 VA 1140 VA COMPACTOR --VA 0 VA WATER HEATER 0 VA 0 VA HYDROMASSAGE BATHTUB --VA 0 VA MICROWAVE 1500 VA 1500 VA BUILT -IN VACUUM 0 VA 0 VA SUBTOTAL 2640 VA 5 OPTIONAL SUBTOTAL (ADD ALL OF THE ABOVE TOTALS)19900 VA 6 APPLYING DEMAND FACTORS -TABLE 220-30 FIRST 10,000VA @ 100%10,000 VA REMAINING VA @ 40% (SUBTOTAL ABOVE - 10,000) X 40%3960 VA 7 HEATING OR AC LOAD - TABLE 220-30 10000 LARGER OF THE HEATING OR AC LOAD 0 VA 8 POOL PANLE/EQUIPMENT 0 VA 9 OPTIONAL TOTAL VOLT AMPS (ADD TOTAL FROM LINE 6+7)23960 VA 10 MINIMUM SERVICE SIZE (OPTIONAL LOAD TOTAL VA /240 VOLTS) =100 AMPS SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS A.PURPOSE 1.THE FOLLOWING INFORMATION INCLUDES THE BASIC PERMIT APPLICATION REQUIREMENTS FOR A 120/240 VOLT SINGLE PHASE ELECTRICAL SERVICE RATED GREATER THAN 200 AMPERES, BUT NOT OVER 600 AMPERES, INSTALLED ON A SINGLE FAMILY RESIDENTIAL LOT. 2.CAUTION: THIS HANDOUT AND THE NATIONAL ELECTRICAL CODE ARE NOT INTENDED AS DESIGN SPECIFICATIONS NOR INSTRUCTION MANUALS FOR UNTRAINED PERSONS. NEC 90.1(C). THE NATIONAL ELECTRICAL CODE REQUIRES QUALIFIED PERSONS TO DESIGN ELECTRICAL INSTALLATIONS. B.SCOPE 1.IN GENERAL, THE ELECTRICAL EQUIPMENT AND WIRING UNDER THE OWNERSHIP OR RESPONSIBILITY OF THE SERVING ELECTRICAL UTILITY IS NOT REGULATED BY THE NEC. THE APPLICABLE SERVING UTILITY MUST BE CONTACTED FOR ANY ADDITIONAL REQUIREMENTS. 2.UNLESS OTHERWISE NOTED, CODE REFERENCES SHALL BE FROM THE 2005 NATIONAL ELECTRICAL CODE (NFPA 70 - NEC) AS AMENDED BY THE CURRENT CITY ADOPTED ORDINANCE. 3.THIS SHOULD NOT BE CONSIDERED AS A COMPLETE LIST OF CODE REQUIREMENTS. ELECTRICAL INSPECTIONS MUST BE PERFORMED AND ”APPROVED” BEFORE THE WORK IS CONSIDERED COMPLETED BY THE CITY OF SAN LUIS OBISPO. C.DEFINITIONS (NEC ARTICLE 100) 1.QUALIFIED PERSON – ONE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE EQUIPMENT AND THE HAZARDS INVOLVED, I.E. LICENSED ELECTRICAL ENGINEER OR LICENSED ELECTRICAL CONTRACTOR. 2.SERVICE (ELECTRICAL) – THE CONDUCTORS AND EQUIPMENT FOR DELIVERING ELECTRIC ENERGY FROM THE SERVING UTILITY TO THE WIRING SYSTEM OF THE PREMISES SERVED. 3.SERVICE POINT – THE POINT OF CONNECTION BETWEEN THE FACILITIES OF THE SERVING UTILITY AND THE PREMISES WIRING. 4.SERVICE EQUIPMENT – ALSO REFERRED TO AS THE SERVICE ENTRANCE SECTION OR “SES”. THE NECESSARY EQUIPMENT USUALLY CONSISTING OF CIRCUIT BREAKERS OR SWITCHES AND FUSES CONNECTED TO THE LOAD END OF SERVICE CONDUCTORS TO A BUILDING OR OTHER STRUCTURE, OR AN OTHERWISE DESIGNATED AREA, AND INTENDED TO CONSTITUTE THE MAIN CONTROL AND CUTOFF SUPPLY. 5.SUBSERVICE – THE NECESSARY EQUIPMENT CONNECTED TO THE LOAD SIDE OF SERVICE EQUIPMENT 6.SUB-PANEL OR PANEL – A TRADE TERM FOR SUBSERVICE PANELBOARDS OR LOAD CENTERS. 7.PREMISES WIRING – ALL ON-SITE WIRING FROM THE SERVICE POINT TO THE END UTILIZATION OUTLET. 8.FEEDERS – ALL CIRCUIT CONDUCTORS BETWEEN THE SERVICE EQUIPMENT AND THE FINAL OVERCURRENT DEVICE (CIRCUIT BREAKER). D.LOCATION 1.ELECTRICAL UTILITY: WHILE IN THE PLANNING STAGE AND BEFORE PERFORMING ANY WORK, CONTACT THE SERVING ELECTRICAL UTILITY REGARDING THE LOCATION OF THE SERVICE POINT, INSTALLATION REQUIREMENTS, EQUIPMENT TYPE AND REQUIRED CLEARANCES. 2.CLEARANCES IN FRONT OF THE SES AND SUB-PANELS NEC 110.26: (a)A MINIMUM THREE (3) FOOT DEEP LEVEL SPACE IN FRONT OF THE EQUIPMENT. NEC 110.26(A)(1). (b)MINIMUM 2’-6” (30”) WIDE SPACE OR WIDTH OF EQUIPMENT, WHICHEVER IS GREATER. NEC 110.26(A)(2). (c)EQUIPMENT DOORS MUST BE ABLE TO FULLY OPEN 90 DEGREES. NEC 110.26(A)(2). (d)MINIMUM 6’-6” HIGH OR TOP OF THE EQUIPMENT, WHICHEVER IS HIGHER. NEC 110.26(A)(3), 110.26(E). (e)THE ACCESS AND WORK SPACE SHALL NOT BE USED FOR STORAGE. NEC 110.26(B). 3.OUTDOOR/WATER/MOISTURE – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO WATER OR MOISTURE ON A REGULAR BASIS OR IN LARGE QUANTITIES, I.E. WHERE EXPOSED TO LAWN SPRINKLERS OR BELOW A ROOF SCUPPER. NEC 110.26(F). 4.VEHICULAR TRAFFIC – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO DAMAGE BY VEHICULAR TRAFFIC. NEC 110.26(F). 5.CLOTHES CLOSETS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN CLOTHES CLOSETS. NEC 240.24(D). 6.BATHROOMS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN BATHROOMS. NEC 240.24(E). 7.SEPARATE BUILDINGS – REFER TO NEC 225.30 PART B, 250.32, 250.50, 250.104 FOR REQUIRED DISCONNECTING MEANS, GROUNDING, AND BONDING. E.PERMIT AND PLAN REQUIREMENTS 1.SITE (PLOT) PLAN: PROVIDE A SIMPLE SITE PLAN (MINIMUM SCALE 1:40) INDICATING THE LOCATION OF EXISTING BUILDING(S), STRUCTURES, FENCES, POOLS, SPAS, ETC, AND THE LOCATION OR AREA WHERE THE SERVICE AND PANELBOARDS ARE TO BE INSTALLED. REFER TO THE SITE PLAN INCLUDED. 2.SINGLE LINE (FEEDER) DIAGRAM NEC 215.5. – DIAGRAM(S) ARE INCLUDED FOR REVIEW. 3.LOAD CALCULATIONS NEC 220 – PROVIDE ELECTRICAL LOAD CALCULATIONS FOR THE ELECTRICAL SERVICE (SES) AND EACH SUB-SERVICE PANEL TO BE INSTALLED. THE STANDARD OR OPTIONAL METHOD MAY BE USED. A COMPLETED OPTIONAL METHOD IS ATTACHED. EXAMPLES OF BOTH METHODS ARE LOCATED IN APPENDIX D OF THE NEC. F.INSPECTION REQUIREMENTS THE INSPECTION CARD LISTS IN DETAIL THE REQUIRED INSPECTIONS. THE FOLLOWING INSPECTIONS ARE FOR YOUR INFORMATION AND MAY VARY DEPENDING UPON THE INSTALLATION. 1.ROUGH ELECTRICAL 2.FINAL ELECTRIC 3.TEMPORARY ELECTRIC IN PERMANENT POSITION IS AN OPTION THAT CAN ALSO BE USED. AN APPLICATION AND REFUNDABLE DEPOSIT ARE REQUIRED. 4.FOR SERVICE SHUT DOWNS, PLEASE CALL INSPECTION SERVICES TO ARRANGE AN INSPECTION. Electric Panel Requirements / Calculations Basis of Design - Plumbing Calculation EXISTING RESIDENCE. EXISTING WATER PRESSURE AT HOSE BIB CLOSEST TO WATER METER MEASURES 65 PSI. FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 1 1/2"2.5 2.5 LAV SINK 1 1/2"1.5 1.5 KITCHEN SINK 1 1/2"1.5 1.5 COMBINATION TUB / SHOWER 1 1/2"4.0 4.0 DISHWASHER 1 1/2"1.5 1.5 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 17.5 PROPOSED ADU FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 2 1/2"2.5 5.0 LAV SINK 2 1/2"1.5 3.0 KITCHEN SINK 1 1/2"1.5 1.5 COMGO BATH/SHOWER 2 1/2"4.0 8.0 SHOWER 2 1/2"2.0 4.0 DISHWASHER 0 1/2"1.5 0.0 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 20.0 TOTAL (EXISTING RESIDENCE + ADU)37.5 PLUMBING CALCULATION NOTES: 1.THE EXISTING WATER METER IS A 3/4" SIZE WITH A 3/4" BUILDING SUPPLY LINE ON THE CUSTOMER SIDE OF THE METER. USING TABLE 610.3/610.4 FROM THE 2022 CA PLUMBING CODE TO DETERMINE PROPOSED AND EXISTING “WATER SUPPLY FIXTURE UNITS” (WSFU), THE COMBINATION OF EXISTING AND PROPOSED FIXTURE UNITS DOES NOT FALL WITHIN THE ACCEPTABLE RANGE, AND THEREFORE: 2.THE EXISTING 3/4" WATER METER WILL BE UPGRADED WITH A 1" WATER METER AND THE 3/4" BUILDING SUPPLY LINE SHALL BE UPGRADED WITH A 1" BUILDING SUPPLY LINE IN ORDER TO BE ADEQUATE FOR THE PROPOSED ADU. MEP3 Exterior Lighting Compliance Exterior Light Specs N.T.S.C Photometric Compliance Plan N.T.S.B CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0305 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 S0.1 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S0.2 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.1 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.2 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.3 Typical Details Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.4 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the ar chi t ec t. Ti t le t o these plans a nd speci f ications remains with cwa studios without prejudice. Visual con t ac t with t hes e plan s an d s peci f ic a t io ns shal l constitute prima face evidence of the acceptance of t h e s e re s t ri c t i o ns . c 20 20 c wa s t u di osproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.1 Foundation Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.2 Second Floor Framing Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.3 Roof Framing Plan = "'-U') � 00a, '<I' "' "' -"' C: ;;.: C0 ·- '<I' Cl < "" C: u ;:;;­..,, • 0 1'--1 o e �-----,- C. I!! .!!! � .i � 00 Jj�---- '-' a, c:: ;;: 0 --'E C.C. "' Q) .lo:: N06J735 Q) > ·;::Cl ,-0""' M c) U") 0""' M C) VJ <'Cl E c..:i C) 0·a5 :I: VJ 0 :c C: 0� :::::s e en0 '- ·-a: Q) C: U) ...J ..c: M C: 0 I.D t'tl --, ,- U) revision: rllV dimipti111 PC CORREC'IDN legal stuff: :::, ..c u. ti 0 2 � 00 � WJ!ldate by 00.15.25 The use of these plans and specifications shall be rn.strlcted ta the use of the orlglrial site for wlllch they were prepared and publication thereof is expressly limtted to such use unless otherwise approved by the architect. Title to these plan3 and specifications remains with cwa studios without prejudice. Visual contact wllll these plans end apeclflcatlons shell constitute pr1ma face evidence of the acceptance of these restrictions c 2020 cwa studios sheet data: SWAjob no: CAD file:drawn by: plot dare: sheet title: 25053.01 JI/ 11.22.25 Structural Details sheet: S3.1 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S3.2 Structural Details Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 3/5/2026 By: Chris Allen, CWA Studios Date: Thursday, March 5, 2026 To: City of San Luis Obispo Community Development Department From: Chris Allen, Architect Re: 1st Code Compliance Review Response Letter Permit No. BLDG-2981-2025 New Attached ADU 619 Grove Street San Luis Obispo, CA 93401 CWA job: 197 The following are responses to the 1st plan review for the above referenced project; comments from the 1st plan review are provided below in half-tone for reference, and responses are provided in red font: California Code Check – Building Review 2022 CBC Comments Wastewater Offset v.2 Nico Gurney 1. Comment: Pursuant to SLOMC 13.08.396, development located within a designated capacity constrained basin that results in intensified wastewater flow is required to offset the projected increase in wastewater discharge. Intensified development includes, but is not limited to, an increase in residential units or density, an increase of 450 square feet or more of habitable residential or nonresidential floor area (excluding garages and accessory structures without plumbing fixtures), or an increase in plumbing fixture units of 10 percent or more above existing conditions. The proposed project appears to meet one or more of these thresholds within a capacity constrained basin and is therefore subject to the Wastewater Flow Offset Program. Prior to issuance of a building permit, demonstrate compliance with SLOMC 13.08.396. Submit a completed Wastewater Offset Flow Application and provide current project plans identifying existing and proposed uses, existing and proposed habitable floor area, existing and proposed plumbing fixture units, and any proposed sewer lateral modifications. If the applicant believes the project does not constitute intensified development under SLOMC 13.08.396, provide a written calculation comparing existing and proposed floor area, fixture units, and use demonstrating that no net increase in wastewater flow will occur. Building permit issuance is contingent upon Utilities verification that wastewater flow offset requirements have been satisfied. Response: Wastewater offset application has been added to the submittal, along with current project plans. Plan Check Response Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 3/5/2026 By: Chris Allen, CWA Studios Utilities Project Manager (Building) v.2 Nico Gurney 2. Comment: Sheet AS1.0: Does sewer lateral from parcel one also feed the proposed sewer pump? Response: No. The sewer lateral from parcel one is its own entity, and does not feed into the proposed sewer pump. Public Works Permit Review v.2 Emma Laplante elaplant@slocity.org 8057817199 3. Comment: 1. Include the following note under Standard Public Works Notes a. All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Response: Please see comment i under “Standard Public Work Notes” on sheet T1.0 for above language. 4. Comment: 2. These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Response: Understood. 5. Comment: 6. Clarify the Proposed drainage strategy a. If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. Resolved b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. Comment Remain: Water shall not be pumped into the street. Invert/location needs to be revised to allow for gravity flow into the street. c. Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain. Resolved d. Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Resolved Response: a) Resolved. b) Invert elevation has been updated to show gravity flow from the catch basin to the street. Please see new detail 4/AS1.2 for further clarity. c) Resolved. d) Resolved. 6. Comment: 7. Revise Plans as follows: a. For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. Resolved b. Show existing utility on all sheets with a line, not just a callout. c. Clearly show the drive approach and driveway on the plans. Comment Remains: Through additional research it seems like the drive approach is being converted to curb under BLDG-1030-2023/ENCR-0189-2026. In addition is also appears that the Majority of the driveway will be replace with concrete under the same permit. Please revise the plans to reflect the changes under the above listed permit. d. There are abbreviations used that are not included in the legend. Resolved e. A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed. Comment remains: TOPO shows brick pavers where the ADU is going but there are no call outs to Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 3/5/2026 By: Chris Allen, CWA Studios remove them. Please clarify f. Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g. The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. Comment remain: plans need to reflect the improvement outline in BLDG-1030- 2023/ENCR-0189-2026 h. Show the material of the existing utility. See the attached Utility grid maps for reference. Resolved i. Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach. Resolved Response: a) Resolved. b) Existing utility on plans are represented with both a line and a callout. Sizes for street utility are also provided on drawing 1/AS1.1. Please refer to the symbol legend on sheet AS1.1 for clarity as to which line represents which utility. c) It appears that the driveway approach was not converted to concrete per the previous plan set. The google earth image from September 2025 still shows pavers at the driveway approach. Notes 4/AS1.0 and 32/AS1.1 now call out this diveway approach to be converted to concrete. d) Resolved. e) Please refer to newly added sheet reference note 1/ SV1.1 for clarity as to brick pavers being removed. f) Utility box has been drawn in on drawing 1/AS1.1. Please see sheet reference note 30/AS1.1. g) Plans have been updated to reflect the removal and replacement of pavers to install the piping leading up to the street. Please refer to notes 1/AS1.0 and 5/AS1.1 for further clarity. h) Resolved. i) Resolved. 7. Comment: 8. The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Resolved: See utility comments Response: Understood. 8. Comment: 9. Additional Plan Comments a. There is a discrepancy in the property line between the approved build plans for Parcel 1 (back parcel) and current plans for Parcel 2. Provide verification from the survey on which property line location is correct. Response: The property line on the previous plan set appears to be incorrect. The survey on sheet SV1.1, completed on July 30th, 2024, is the most up to date drawing and shows an accurate representation of the existing site conditions. Please refer to our drawing set for the correct site conditions. Fees v.2 Vanessa Nichols vnichols@slocity.org 8057817588 9. Comment: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Response: This shall be resolved prior to permit issuance. John Rourke (The property owner) has been in conversation with community development staff on resolution of this item. Final determination on how to proceed is pending and will be provided once it is available. 10. Comment: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. PARTIAL COMMENT REMAINS: Plumbing calc needs to reflect the upgrade of water meter and service. Sheet Reference Note #9. Sheet S1.1, needs to be update to reflect the water meter being upgraded. Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 3/5/2026 By: Chris Allen, CWA Studios Response: Plumbing calc and sheer reference note 9/AS1.1 have been updated to reflect both the water meter and the service to be upgraded. 11. Comment: #3 Final fees pending response to comments and other department reviews. Response: Understood. Building v.2 Yazneed Hassan yazneedh@tncservices.com 5627338030 12. Comment: G1. Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Corrective Action: PC2: Comment remains. Provide updated checklist. Response: Updated sheets and checklist have been provided per comment. 13. Comment: S2. Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Corrective Action: PC2: No geotechnical report is provided. Remove the slab on grade note on sheet S2.1 referring to a geotechnical report. Response: Note has been removed as requested. See updated Sheet S2.1. Arborist v.2 Walter Gault wgault@slocity.org 8057817578 14. Comment: Per Uniform Design Criteria 1010 3.1.23 Street Trees, a minimum of one street tree shall be installed per 35 feet of street frontage for any commercial or residential building permit addition or new dwelling unit, unless City Arborist determines that the site cannot accommodate a new tree. Street trees may be grouped if necessary to avoid conflict with other improvements. Please select a street tree from the City Approved Tree List (Zone 1 tree species), and if in a Fire Hazard Severity Zone, the City of SLO Zone 1 Defensible Space Tree List. Street trees may be planted in front yards to satisfy the requirement. Corrective Action: Please provide a landscaping plan that satisfies the Uniform Design Criteria 1010 3.1.23 Street Trees requirement. Plan shall include tree species selected from Engineering Standard (8010) and Zone 1 category, tree size, location, City Engineering Standards for Tree Planting (8210, 8220, 8250) and an irrigation detail (8670 Tree Bubbler or 8660 Drip Irrigation). Response: Please see “Compensatory Replanting Tree Schedule” for information as to the species, size and irrigation method for the new tree. Kindly also refer to note 31/AS1.1 for location of said tree. 15. Comment: If a tree protection and monitoring plan is necessary or a tree removal application and compensatory replanting plan is required, please provide a project arborist to oversee all arboriculture activities. Corrective Action: Please provide a tree protection plan on demo, grading and building permit plan submittals that satisfies Specification 77-1.03A(2) and identifies the location, type, trunk and canopy diameter of all trees onsite (and adjacent offsite) and explains the likelihood of tree retention (based on impact to the critical root zone of trees on- and offsite). An Arborist Report providing further information may be required. Response: There are no trees impacted by the proposed ADU, and therefore an arborist report will not be required for this project. Planning v.2 Ethan Estrada ejestrad@slocity.org 8057817576 16. Comment: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Response: Understood. 17. Comment: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 3/5/2026 By: Chris Allen, CWA Studios compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Response: Please see spec sheet C/MEP2 for lighting specs. Owner shall choose fixtures that are or are equal to said lighting fixture to maintain compliance with SLOMC 17.70.100. 18. Comment: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Response: Please see newly added sheet MEP2 for exterior lighting compliance. Drawings A /MEP2 and B/MEP2 show lighting values around and at the property line to be in compliance with SLOMC 17.70.100. 19. Comment: Upon further review, it's been noted that the site plan shows what appears to be another condenser on the south side of the proposed ADU that encroaches into the existing easement. This equipment is not shown on any other sheet in the plan set. Is this condenser supposed to be a part of this project? If it is, it will need to be relocated out of the existing easement. Response: Thank you for catching this. Said condenser has been removed. The condenser location is now correctly shown to be along the northern building face. END WASTEWATER FLOW OFFSET APPLICATION Implementing City of San Luis Obispo Municipal Code Section 13.08.396 (Please Print) City Application #: Property Address: Applicant Name/Point of Contact: Phone Number/Email Address: Applicant Signature: Date: Required Wastewater Flow Offset: gallons per day or laterals Completed Sewer Lateral Replacements (provide address and City encroachment permit number for each offset)*: 1. 2. 3. 4. 5. *NOTES: 1) All permit work for sewer lateral replacements must receive final sign off to qualify as a wastewater flow offset. 2) Wastewater flow offset must be completed prior to a project ’s Building Permit issuance. City of San Luis Obispo Contact: Utilities Engineer Phone: 805-781-7215 Email: wastewateroffset@slocity.org OFFICIAL USE ONLY: Verification (Sign): (Print): Title: Date: BLDG-2981-2025 619 Grove Street, San Luis Obispo, CA 93401 Chris Allen 8052865186 cwa.arch@gmail.com 03/02/2026 150 619 Grove Street, San Luis Obispo, CA 93401 City of San Luis Obispo Wastewater Flow Offset Application Page 2 Application #: Property Address (or Addresses): WASTEWATER FLOW OFFSET CALCULATION WORKSHEET Residential Development1: Residential Units Proposed (in EDU): Residential Wastewater Flow (# EDU x 150 gpd): RESIDENTIAL FLOW TOTAL (gallons per day): Non-Residential Development2: Commercial Square Footage: Industrial Square Footage: Manufacturing Square Footage: Business Park Square Footage: Hotel/Motel Rooms: Non-Residential Wastewater Flow2: NON-RESIDENTIAL FLOW TOTAL (gallons per day): TOTAL WASTEWATER FLOW OFFSET (gallons per day): NOTES: 1.EDU = Equivalent Dwelling Unit. One single family residence 1,200 square feet or greater equals one EDU. 2.Wastewater generation factors for residential and non-residential development are provided in the City’s Engineering Standards, Uniform Design Criteria. DESCRIPTION THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. SITE INFORMATION EXISTING BUILDING INFORMATION JURISDICTION ZONING APN STREET ADDRESS GROSS LOT SIZE BUILDING AREAS PROPOSED INFORMATION TWONUMBER OF STORIES R-3 (RESIDENTIAL)OCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE SPRINKLERED CLASS A ROOFINGROOF RATING TWO STORYNUMBER OF STORIES R-3 (RESIDENTIAL) / UOCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSEDFIRE SPRINKLERS CITY OF SAN LUIS OBISPO LOW DENSITY RESIDENTIAL (R-1) 001-056-052 619 A GROVE STREET, SAN LUIS OBISPO, CA 93401 0.08 ACRES (3,589 SF) CLASS AROOF RATING 25 FEET ALLOWEDMAXIMUM HEIGHT PROPERTY IS NOT LOCATED WITHIN A HIGH FIRE RISK AREA OR FLOOD PLAIN AREAHAZARDS LOT COVERAGE MAX 40% = 3,589 X 0.4 = 1,436 SF. PROPOSED = 862 SF. 862 / 3,589 = 24% (ADU EXCLUDED FROM LOT COVERAGE CALCULATIONS PER MC § 17.70.120(B)(5)) 1 SPACE PROVIDED IN DRIVEWAY PER PREVIOUS LOT SPLITPARKING LEGAL DESCRIPTION CY SLO PM 84/92-93 PAR 2 1 SPACE PROVIDED IN DRIVEWAYPARKING NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSED T1.0 Title Sheet, General Notes + Project Data Sheet Index OWNER Project Directory SOILS ARCHITECT CWA STUDIOS 1668 SYDNEY STREET SAN LUIS OBISPO. CA 93401 CONTACT: CHRIS ALLEN, AIA. 805 286 5186 Drawing Log SET ISSUE DATE REVISION Project Notes ENERGY CARSTAIRS ENERGY CALCULATIONS 2238 BAYVIEW HEIGHTS DRIVE, SUITE E LOS OSOS, CA 93402 CONTACT: TIM CARSTAIRS. 805 904 9048 Project Data T1.1 INDEX, DATA + NOTES STRUCTURAL Calgreen Mandatory Measures 1.PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL SHALL MANAGE STORMWATER DURING CONSTRUCTION. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. CALGREEN 4.106.2.2 2.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED AND SHALL COMPLY WITH THE PLUMBING FIXTURE AND FITTINGS SCHEDULE ON THIS SHEET. CALGREEN 4.303.3.1 3.AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1 - CONTROLLERS SHALL BE WEATHER- OR SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANT WATERING NEEDS AS WEATHER OR SOIL CONDITIONS CHANGE. 2 - WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). CALGREEN 4.304.1 4.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE CLOSED WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY TO PREVENT PASSAGE OF RODENTS. CALGREEN 4.406.1. 5.RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 60% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4; OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. CALGREEN 4.408.1 6.DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION PER CALGREEN 4.504.1. 7.ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS PER CALGREEN 4.504.2.1. 8.PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.2.2. 9.AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS PER CALGREEN 4.504.2.3. 10.DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED PER CALGREEN 4.504.2.4. 11.CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.3. 12.EIGHTY (80) PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERINGINSTITUTE (RFCI) FLOORSCORE PROGRAM PER CALGREEN 4.504.4. 13.PARTICLEBOARD, MEDIUM FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR OR EXTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS PER CALGREEN 4.504.5. 14.VAPOR RETARDER AND CAPILLARY BREAK OF 4” THICK BASE OF ½” OR LARGER CLEAN AGGREGATE SHALL BE INSTALLED AT SLAB ON GRADE FOUNDATIONS PER CALGREEN 4.505.2. 15.MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING SHALL BE CHECKED BEFORE ENCLOSURE PER CALGREEN 4.505.3. 16.BATHROOM EXHAUST FANS SHALL BE DUCTED TO TERMINATE OUTSIDE AND BE PROVIDED IN EVERY BATHROOM PER CALGREEN 4.506.1. 17.WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED LOUVERS OR COVERS WHICH CLOSE WHEN THE FAN IS OFF. COVERS OR LOUVERS SHALL HAVE A MINIMUM INSULATION VALUE OF R-4.2 PER CALGREEN 4.507.1. 18.PER CALGREEN 4.507.2 DUCT SYSTEMS ARE SIZED, DESIGNED, AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS: 1. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ACCA (MANUAL J) OR EQUIVALENT. 2. SIZE DUCT SYSTEMS ACCORDING TO ACCA 26-D (MANUAL D) OR EQUIVALENT. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S (MANUAL S) OR EQUIVALENT. 19.OPERATION + MAINTENANCE MANUAL TO BE SUPPLIED AT FINAL INSPECTION. 20.MANAGE STORMWATER PER CALGREEN CODE REQUIREMENTS. 4106.2 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 25.1222 Deferred Submittals / Separate Permits 1.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDER-DRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. SURVEY MBS LAND SURVEYS 3559 SOUTH HIGUERA ST. SAN LUIS OBISPO CA 93401 CONTACT: MICHAEL B STANTON 805 594 1960 ARCHITECTURAL1.ALL WORK SHALL BE IN CONFORMANCE WITH THE 2022 EDITIONS OF THE CALIFORNIA BUILDING CODES 2.ANY/ALL DEFERRED SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT AND/OR PROJECT ENGINEER PRIOR TO SUBMISSION TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL. 3.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. 4.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. 5.THE PUBLIC IMPROVEMENTS SHALL BE SUBSTANTIALLY COMPLETE TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR PRIOR TO FINAL INSPECTION APPROVALS AND/OR OCCUPANCY OF ANY BUILDING. 6.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER AND SIDEWALK OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 7.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 805 781 7554 WITH AT LEAST A 48 HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. 8.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. 9.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. 10.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED DURING ALL CONSTRUCTION AND GROUND DISTURBING ACTIVITIES PER THE CITY OF SAN LUIS OBISPO 11.TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN PERMANENT IMPROVEMENTS, PLANTINGS AND FACILITIES ARE IN PLACE. TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION APPROVALS. 12.THE EXISTING SEWER LATERAL SHALL BE TELEVISED AND APPROVED FOR REUSE OR SHALL BE REPAIRED/REPLACED. THE INSPECTION SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE UTILITIES DEPARTMENT PRIOR TO ISSUANCE OF A BUILDING PERMIT. 13.ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE VERTICAL AND GREATER AND AREAS USED TO CONVEY CONCENTRATED DRAINAGE SHALL BE PREPARED AND MAINTAINED TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED NO LATER THAN 30 DAYS PRIOR TO A REQUEST FOR FINAL INSPECTION APPROVAL. 14.REMODELING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS A VIOLATION OF CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELERS AND PAINTERS ARE REQUIRED TO USE "LEAD-SAFE" WORK PRACTICES PURSUANT TO TITLE 17, CA CODE OF REGULATIONS SECTION 36050. 15.PRIOR TO ANY DEMOLITION OR GRADING THE CONTRACTOR SHALL PROTECT ANY TREES ADJACENT TO THE WORK ZONE. 16.THE MANDATORY PROVISIONS OF CALGREEN CHAPTER 4 SHALL BE APPLIED TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. CALGREEN 301.1.1 17.ON AND AFTER JANUARY 1, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. CALGREEN 301.1.1 18.APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER ORDINANCE OR LAW. CBC 105.4 19.THIS PROJECT IS LOCATED IN THE HIGH FIRE SEVERITY ZONE AS PER CITY OF SAN LUIS OBISPO California Building Code Chapter 7A Req. THE CITY OF SAN LUIS OBSIPO IS CONSIDERED A "COMMUNITY AT RISK" DUE TO THE THREAT OF WILDFIRE IMPACTING THE URBAN COMMUNITY. THE CITY SHALL CONTINUE TO ENHANCE THE FIRE SAFETY AND CONSTRUCTION CODES FOR NEW BUILDINGS IN ORDER TO REDUCE THE RISK OF URBAN FIRES THAT MAY RESULT FROM WILDFIRES. NEW BUILDINGS CITYWIDE SHALL INCORPORATE THE FOLLOWING CONSTRUCTION METHODS AND MATERIALS: IGNITION RESISTANT EXTERIOR WALL COVERINGS; FIRE SPRINKLER PROTECTION IN ATTIC AREAS (AT LEAST ONE "PILOT HEAD"); EMBER RESISTANT VENT SYSTEMS FOR ATTICS AND UNDER FLOOR AREAS, PROTECTED EAVES AS IDENTIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7A. CRC R337.1.2. STORK, WOLFE & ASSOCIATES 555 CHORRO ST. SUITE A1 SAN LUIS OBISPO, CA 93401 CONTACT: JUSTIN WOLFE, PE. PH: 805 548 8604 STRUCTURAL AS1.1 ARCHITECTURAL SITE PLAN T1.2 A3.1 EXISTING BUILDING ELEVATIONS A5.2 ARCHITECTURAL DETAILS S0.1 STRUCTURAL GENERAL NOTES S1.4 TYPICAL DETAILS S1.2 TYPICAL DETAILS S2.2 S2.3 ROOF FRAMING PLAN SECOND FLOOR FRAMING PLAN S0.2 STRUCTURAL GENERAL NOTES S1.1 TYPICAL DETAILS A4.1 PROPOSED BUILDING SECTIONS S1.3 TYPICAL DETAILS S2.1 FOUNDATION PLAN S3.1 STRUCTURAL DETAILS CALGREEN MANDATORY MEASURES G r o v e S t r e e t R e s i d e n t i a l A d d i t i o n 6 1 9 A G r o v e S t r e e t , S a n L u i s O b i s p o , C A 9 3 4 0 1 A5.1 ARCHITECTURAL DETAILS N/A T1.3 CALGREEN MANDATORY MEASURES Vicinity Map S3.2 STRUCTURAL DETAILS Construction Documents for SV1.1 EXISTING TOPOGRAPHIC SURVEY PROJECT LOCATION CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25BUILDING AREAS (EXISTING) (PROPOSED) PRIMARY RESIDENCE (EXISTING) 1,287 SQ. FT. PROPOSED ADU GROUND FLOOR 490 SQ. FT. SECOND FLOOR 430 SQ. FT. TOTAL (INCLUDING EXISTING RESIDENCE) 2,292 SQ. FT. N/ASOILS REPORT JOHN ROURKE 163 SERRANO HEIGHTS DRIVE SAN LUIS OBISPO. CA 93405 CONTACT: JOHN ROURKE. PH: 805 440 4973 A2.1 PROPOSED FLOOR PLANS + ROOF PLAN A3.2 PROPOSED BUILDING ELEVATIONS AS1.2 ARCHITECTURAL SITE DETAILS Standard Public Works Notes a.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. (THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. b.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY, WITHIN CITY EASEMENTS, OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. c.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK, OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. d.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST A 48-HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. e.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. f.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. g.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. h.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. i.ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT LESS THAN 2% SHALL HAVE FINAL GRADIENTS CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER PRIOR TO FINAL INSPECTION APPROVALS. Stormwater Compliance Summary THE PROJECT IS NOT A REGULATED PROJECT SUBJECT TO REGIONAL WATER QUALITY CONTROL BOARD RESOLUTION R3-2013-0032 “POST CONSTRUCTION STORMWATER MANAGEMENT REQUIREMENTS FOR DEVELOPMENT PROJECTS IN THE CENTRAL COAST REGION” BASED ON THE FOLLOWING: ☒PROJECT DOES NOT CREATE AND/OR REPLACE 2,500 SQUARE FEET OR MORE OF IMPERVIOUS AREA ☐PROJECT TYPE IS LISTED IN SECTION B.1.B (STATE WHICH): Applicable Governing Codes: 2022 2022 2022 CALIFORNIA BUILDING CODE, VOLUMES 1+2 CALIFORNIA ELECTRIC CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA GREEN BUILDING CODE CALIFORNIA FIRE CODE CALIFORNIA ENERGY CODE CALIFORNIA RESIDENTIAL CODE 2022 2022 2022 2022 2022 SAN LUIS OBISPO MUNICIPAL CODE NOT TO SCALE T1.4 ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS T1.0 A5.3 FIRESTOPPING DETAILS SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0220 HERS Feature Summary THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY A CERTIFIED HERS RATER AS A CONDITION FOR MEETING THE MODELED ENERGY PERFORMANCE FOR THIS COMPUTER ANALYSIS. ADDITIONAL DETAIL IS PROVIDED IN THE BUILDING TABLES ON SHEET T1.3. REGISTERED CF2RS AND CF3RS ARE REQUIRED TO BE COMPLETED IN THE HERS REGISTRY •INDOOR AIR QUALITY VENTILATION •KITCHEN RANGE HOOD •VERIFIED EER/EER2 •VERIFIED SEER/SEER2 •VERIFIED REFRIGERANT CHARGE •AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7) •VERIFIED HSPF •VERIFIED HEAT PUMP RATED HEATING CAPACITY •WALL-MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 FT2 (SC3.4.5) • DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONDITIONED SPACE (SC3.1.4.1.8) A5.4 ARCHITECTURAL DETAILS AS1.0 SITE DEMO / GRADING PLAN MEP2 ELECTRICAL FLOOR PLANS + NOTES ARCHITECTURAL MEP3 MEP CALCULATIONS EXTERIOR LIGHTING COMPLIANCE MEP1 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0305 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0319 T1.1 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 Y ALL Y Y ALL Y CONT CONT N/A N/A N/A N/A N/A N/A N/A N/A Y ALL Y OWNER Y ALL Y CONT Y OWNER Y CONT Y CONT Y CONT Y OWNER Y OWNER N/A N/A N/A T1.2 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 N/A N/A Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y OWNER Y CONT Y CONT Y CONT T1.3 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 T1.4 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 SV1.1 Existing Topographic Survey TOPOGRAPHIC MAPJOHN constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 Sheet Reference Notes 1.EXISTING BRICK PAVERS TO BE REMOVED 1 1 1 1 1 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 AS1.0 Site Demo / Grading Plan Sheet Reference Notes 1.PORTION OF DRIVEWAY TO BE REMOVED FOR NEW UTILITIES, SHADED. PAVERS WILL BE PUT BACK IN PLACE ONCE WORK IS COMPLETE 2.NEW TOPOGRAPHY LINES THROUGH SITE GRADING TO ALLOW FOR DRAINAGE TO FLOW TOWARDS THE SUMP PUMP VIA A 1% SLOPE. 3.AREA OF SIDEWALK TO BE REMOVED TO PLACE SIDEWALK UNDER-DRAIN, AND TO BE RESTORED FROM SCORE MARK TO SCORE MARK AFTER DRAIN INSTALLATION IS COMPLETE. 4.DRIVEWAY APPROACH TO BE CONVERTED 331.1' FG. 331.5' FG. 331.6' TG. 331.4' TG. 331.7' FG. 330.0' INV. 331.0' TG. 329.0' INV. 329.0' INV.330331330SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD SDSD SD SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSC.O. C.O. WM 23'-0"12'-0" 35'-0" 70'-0" RIGHT-OF-WAY 22 1 5% SLO P E 2% SLOPE 2% SLOPE3 4 168420 Architectural Site Plan11/8" = 1'-0" NEW TREE FOR EACH TREE AUTHORIZED TO BE REMOVED WHEN PLANTED ON THE SAME PROPERTY (ON SITE) OR TWO NEW TREES FOR EACH TREE AUTHORIZED TO BE REMOVED WHEN PLANTED ON A DIFFERENT PROPERTY OR WITHIN THE PUBLIC RIGHT-OF-WAY (OFF SITE). COMPENSATORY PLANTINGS SHALL BE OF A SIZE CONSISTENT WITH CITY ENGINEERING STANDARDS AS SET FORTH IN THE CITY OF SAN LUIS OBISPO MUNICIPAL CODE 12.24.090. DRIP IRRIGATION WILL SERVE THE REPLANTED TREES, USING 1.0 GHP EMITTERS. ALL IRRIGATION WORK SHALL MEET THE REQUIREMENTS OF APPLICABLE STATE AND LOCAL CODES. 311 32 25 19 16 Architectural Site Details Liberty Grinder Pump Specification1N.T.S. DensGlass Installation Guide - Fastening and Framing N.T.S.3 Sidewalk Underdrain N.T.S.2 AS1.2 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 MAX). #4 REBAR @ 12" O.C.2" FROM RAINWATER SUMP PUMP, REFER TO SITE PLAN 12" CATCH BASIN, NDS OR EQUAL. 1/4 BEND. Proposed Floor Plans, Roof Plan, and Schedules CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 0 1 2 84 1/4" = 1'-0" Proposed First Floor Plan1 0 1 2 84 1/4" = 1'-0" Proposed Second Floor Plan2 A2.1 Floor Plan Reference Notes 1.HARDWOOD VANITY CABINETS 20" DEEP WITH FINISH COUNTER HEIGHT OF +36" A.F.F. . 2.QUARTZITE COUNTERTOP. USE 2CM SLAB THICKNESS AS DROP EDGE CEASARSTONE, OR EQUAL. COLOR TO BE SELECTED BY OWNER. 3.SINK: KOHLER, OR EQUAL. FAUCET: HANSGROHE BATHROOM FAUCET, OR EQUAL. 4.MIRROR FROM TOP OF COUNTER TO CEILING OR PER OWNERS SELECTION. 5.SHOWER HEAD: KOHLER, OR EQUAL. CONTROLS: THERMOSTATIC/PRESSURE BALANCE MIXING VALVE TO PROVIDE SCALD + THERMAL SHOCK PROTECTION. 6.66" PRE-FABRICATED FIBERGLASS TUB. TOP @ 18" A.F.F.. 7.TOILET: LOW-FLOW AMERICAN STANDARD CADET 3, OR EQUAL. 8.GUARDRAILS; SHALL HAVE A MINIMUM HEIGHT OF 42". INTERMEDIATE RAILINGS SHALL BE SPACED AT A MAXIMUM OF 3-3/4". HANDRAILS; SHALL HAVE A HEIGHT OF 36" WHERE LOCATED IN STAIRWAYS. A MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT IS 31-1/2" WHERE A HANDRAIL IS INSTALLED ON ONE SIDE OF THE STAIRWAY, AND 27" WHERE HANDRAILS ARE INSTALLED ON BOTH SIDES. 9.STAIRS, 7-3/4" MAX RISER / 10" MIN. TREAD DEPTH. TO BE IN COMPLIANCE WITH CRC R311.7. 10.NEW FIXTURES PER CALGREEN MANDATORY MEASURES. 11.INFILL WINDOWS IN EXISTING RESIDENCE WITH OPAQUE WALL. 12.6" SEISMIC GAP BETWEEN EXISTING RESIDENCE AND PROPOSED ADU AS SHOWN, REFERENCE DETAIL 7 ON SHEET A5.2 FOR MORE DETAIL. 0 1 2 84 1/4" = 1'-0" Proposed Roof Plan3 Legend X NEW 2X4 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS NEW 2X6 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS DOOR / WINDOW CALLOUTS; SEE DOOR & WINDOW SCHEDULE THIS SHEET FOR DETAILS 1-HR RATED ASSEMBLY BETWEEN NEW ACCESSORY DWELLING UNIT AND EXISTING RESIDENCE. NEW RATED WALL SHALL EXTEND FROM CONCRETE SLAB TO BOTTOM OF PROPOSED ROOF SHEATHING IN ALL LOCATIONS. REFERENCE DETAIL 4 & 6 ON A5.2 FOR ADDITIONAL INFORMATION. WINDOW AND DOOR NOTES: 1.ALL EXTERIOR DOORS SHALL BE WEATHER-STRIPPED AND SHALL FEATURE WATER-RESISTANT THRESHOLDS AND/OR DOOR BOTTOMS 2.THRESHOLDS SHALL BE 3/4" MAXIMUM AT SLIDERS AND 1/2" MAXIMUM FOR OTHER DOORS. 3.TEMPERED GLAZING SHALL BE PROVIDED WHERE INDICATED IN THESE PLANS IN ACCORDANCE WITH THE REQUIREMENTS FOR HAZARDOUS LOCATIONS [CBC 2406.3] 4.LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-½" LOWER THAN TOP OF THRESHOLD. (THE LANDING / FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 7-¾" BELOW TOP OF THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR.) [R311.3.1] 5.PROVIDE LOCKSETS AND DEADBOLTS ON ALL EXTERIOR HINGED DOORS. 6.WINDOWS THAT SERVE AS A REQUIRED MEANS OF EGRESS ARE DENOTED ON THE EXTERIOR ELEVATIONS. EGRESS WINDOWS SHALL HAVE A MAX DIMENSION OF 44" TO THE OPENING ABOVE THE FLOOR, PROVIDE 5.7 SQUARE FEET OF CLEAR EGRESS AREA WITH 24" MIN. HEIGHT AND 20" MIN. WIDTH. Window Schedule WIDTH HEIGHT FRAMETYPE A 4'-0" B HEADER +80" Door Schedule WIDTH HEIGHT FRAME PANELTYPE 6'-8"EXTERIOR - HINGED 2 1 # # VINYL4'-0" GLAZED, TEMPEREDWOOD 3'-8"2'-6" +80" 3'-0" 6'-8" INTERIOR - HINGED 3 S.C. SLABWOOD 2'-8" VINYLSLIDING SLIDING INTERIOR - HINGED A CLASS "A" COMP SHINGLE ROOFING TO MATCH EXISTING. PRODUCT SHALL MEET OR EXCEED UL 790 (CLASS A FIRE RESISTANCE STANDARD). A DRIP EDGE SHALL BE PROVIDED AT EAVES AND RAKE EDGES OF SHINGLE ROOFS PER R905.2.8.5. 3.METAL GUTTER AND DOWNSPOUT PROVIDED, AS REQUIRED. LOWER ROOF DRAINS TO CONNECT TO LEADERS DOWN TO SITE DRAINAGE CONNECTIONS. INLET SHALL BE EQUIPPED WITH A LEAF STRAINER TO PROHIBIT DEBRIS FROM ENTERING THE DOWNSPOUT. 1 1 2 2 2 3 3 1'-7"1'-10 1/2"1'-10 1/2"1'-10 1/2"1'-8"1'-8"3'-2" 3'-2"3'-1"6" SEISMICGAPLIVING ROOM 101 KITCHEN 102BATH 105 BEDROOM 106 LAUNDRY 104 HALL 103 BATH 203 BEDROOM 202 HALL 201 1/A4.11/A4.1BEDROOM 204 BEDROOM 205 6'-8"4 3'-0"INTERIOR - HINGED S.C. SLABWOOD A3.1 Existing Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S. 4 D 3/4 D 3/4 D 4 D 1 A 2 F 2 F 6 C 8 - 10 - A3.2 Proposed Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S. FIRST LEVEL (0'-0") (FF = 333') F.F. @ SECOND LEVEL (9'-0")(FF = 342') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') A4.1 Proposed Building Sections CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S. -0") TOP PLATE OF WALL (17'-0") WINDOW & DOOR HEADERS (15'-8") AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') Architectural Details CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A Penetrations and Firestopping NOT TO SCALE Bi-Pass Door - Head and Jamb Typical Jamb, Head, and Sill Installation @ Exterior Windows + Doors 3" = 1'-0" 5 1 Through Wall Penetrations and Firestopping N.T.S.4 SYSTEM NO. W-L-1054NOT TO SCALE 8 3" = 1'-0" 6 A5.2 EXTERIOR 7/8" 3-COAT CEMENTIOUS PLASTER SIDING OVER MIN. TWO LAYERS GRADE D BUILDING PAPER. Firestopping Details A5.3 CAD FILE CWA JOB NO DRAWN BY PLOT DATE 2020 1 sheet: sheet data: revision: sheet title: REV DESCRIPTION BYISSUE DATE SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1 SYDNEY STREET, SLO, CA 3401 EMAIL CWA.ARCH GMAIL.COM TELEPHONE 0.2.1 AIA, LEED AP, C-31 CHRISTOPHER W. ALLEN C31 EXP. 0.30.2LIC E N S E D A RCHITE C TS TATE OF C A L I F O R N IA12/22/2 2.031 legal stuff: THE USE OF THES E PLANS AND SPECIFICAT IONS SHALL BE RESTRICTED TO THE USE OF THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE UNLESS OTHERWISE APPROVED BY THE A RC HITECT. TITL E TO T HES E P LA NS AN D S PE CIFI CA T IO NS REMAINS WITH CWA STUDIOS WITHOUT PREJUDICE. VISUAL CONTAC T W ITH TH E SE P LANS AND S PE CI F ICATI O NS S HA LL CONSTITUTE PRIMA FACE EVIDENCE OF THE ACCEPTANCE OF T HES E R EST R I CT ION S. C 2 02  C W A S T U DI O S SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/2 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/0/2 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/1/2 NOSING CONTRASTING 2" (MIN.) TO 4" (MAX.) WIDE STRIPE SET STRIPE NO MORE THAN 1" FROM EDGE OF NOSING 7" RISER10-3/4" 3/4" OCCUPANT SENSORS W/ INTEGRAL PHOTO CONTROL CERTIFIED TO COMPLY W/ SECTION 119(D). General Lighting Notes 3'-8 1/4" 3'-8 1/4" WHOLE-BUILDING VENTILATION REQUIREMENTS (FROM ASHRAE 62.2) AT LEAST ONE MECHANICAL VENTILATION SYSTEM IN THE BUILDING MUST BE DESIGNATED FOR USE IN COMPLIANCE WITH THE WHOLE- BUILDING VENTILATION REQUIREMENT. ALTERNATIVELY, THE SUM OF THE RATED AIR FLOWS FROM MULTIPLE FANS CAN BE UTILIZED TO MEET THE REQUIRED WHOLE BUILDING VENTILATION AIRFLOW. THE SYSTEM(S) MUST DELIVER CONTINUOUS VENTILATION AIRFLOW AT A RATE GREATER THAN OR EQUAL TO THE RATE SPECIFIED IN EQUATION 4.1a, AND FAN SONE RATINGS MUST NOT EXCEED 1.0. FOR DWELLING OCCUPANT DENSITIES KNOWN TO BE GREATER THAN (NBR + 1), THE RATE SHALL BE INCREASED BY 7.5 CFM FOR EACH ADDNL PERSON. Whole House Ventilation Calculation FLOOR AREA (SF)NBR OF BR QFAN (cfm) 920 4 50.40 MEP2 MEP Calculations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 Residential Load Calculations RESIDENTIAL LOAD CALCULATIONS (NEC 220.82) OPTIONAL METHOD NEC 220-30 As an optional method, the STANDARD METHOD, found in ARTICLE 220 of the National Electric Code, may be used 1 GENERAL LIGHTING NOTES SF X 3 VA / SF 920 SF 2760 VA SMALL APPLIANCE LOADS - 220-16 (a) (MIN. 2)1500 VA 3000 VA LAUNDRY LOADS 1500 VA 1500 VA SUBTOTAL 7260 VA 2 COOKING EQPT. LOADS - (NAMEPLATEVALUE) RANGE 5000 VA 5000 VA COOKTOP --VA 0 VA OVEN 0 VA 0 VA SUBTOTAL 5000 VA 3 ELECTRICAL DRYER 220-18 (NAMEPLATE, 5,00 VA MIN) DRYER 5000 VA 5000 VA SUBTOTAL 5000 VA 4 FIXED APPLIANCE LOADS- 230-30(b3) DISHWASHER 0 VA 0 VA DISPOSAL 1140 VA 1140 VA COMPACTOR --VA 0 VA WATER HEATER 0 VA 0 VA HYDROMASSAGE BATHTUB --VA 0 VA MICROWAVE 1500 VA 1500 VA BUILT -IN VACUUM 0 VA 0 VA SUBTOTAL 2640 VA 5 OPTIONAL SUBTOTAL (ADD ALL OF THE ABOVE TOTALS)19900 VA 6 APPLYING DEMAND FACTORS -TABLE 220-30 FIRST 10,000VA @ 100%10,000 VA REMAINING VA @ 40% (SUBTOTAL ABOVE - 10,000) X 40%3960 VA 7 HEATING OR AC LOAD - TABLE 220-30 10000 LARGER OF THE HEATING OR AC LOAD 0 VA 8 POOL PANLE/EQUIPMENT 0 VA 9 OPTIONAL TOTAL VOLT AMPS (ADD TOTAL FROM LINE 6+7)23960 VA 10 MINIMUM SERVICE SIZE (OPTIONAL LOAD TOTAL VA /240 VOLTS) =100 AMPS SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS A.PURPOSE 1.THE FOLLOWING INFORMATION INCLUDES THE BASIC PERMIT APPLICATION REQUIREMENTS FOR A 120/240 VOLT SINGLE PHASE ELECTRICAL SERVICE RATED GREATER THAN 200 AMPERES, BUT NOT OVER 600 AMPERES, INSTALLED ON A SINGLE FAMILY RESIDENTIAL LOT. 2.CAUTION: THIS HANDOUT AND THE NATIONAL ELECTRICAL CODE ARE NOT INTENDED AS DESIGN SPECIFICATIONS NOR INSTRUCTION MANUALS FOR UNTRAINED PERSONS. NEC 90.1(C). THE NATIONAL ELECTRICAL CODE REQUIRES QUALIFIED PERSONS TO DESIGN ELECTRICAL INSTALLATIONS. B.SCOPE 1.IN GENERAL, THE ELECTRICAL EQUIPMENT AND WIRING UNDER THE OWNERSHIP OR RESPONSIBILITY OF THE SERVING ELECTRICAL UTILITY IS NOT REGULATED BY THE NEC. THE APPLICABLE SERVING UTILITY MUST BE CONTACTED FOR ANY ADDITIONAL REQUIREMENTS. 2.UNLESS OTHERWISE NOTED, CODE REFERENCES SHALL BE FROM THE 2005 NATIONAL ELECTRICAL CODE (NFPA 70 - NEC) AS AMENDED BY THE CURRENT CITY ADOPTED ORDINANCE. 3.THIS SHOULD NOT BE CONSIDERED AS A COMPLETE LIST OF CODE REQUIREMENTS. ELECTRICAL INSPECTIONS MUST BE PERFORMED AND ”APPROVED” BEFORE THE WORK IS CONSIDERED COMPLETED BY THE CITY OF SAN LUIS OBISPO. C.DEFINITIONS (NEC ARTICLE 100) 1.QUALIFIED PERSON – ONE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE EQUIPMENT AND THE HAZARDS INVOLVED, I.E. LICENSED ELECTRICAL ENGINEER OR LICENSED ELECTRICAL CONTRACTOR. 2.SERVICE (ELECTRICAL) – THE CONDUCTORS AND EQUIPMENT FOR DELIVERING ELECTRIC ENERGY FROM THE SERVING UTILITY TO THE WIRING SYSTEM OF THE PREMISES SERVED. 3.SERVICE POINT – THE POINT OF CONNECTION BETWEEN THE FACILITIES OF THE SERVING UTILITY AND THE PREMISES WIRING. 4.SERVICE EQUIPMENT – ALSO REFERRED TO AS THE SERVICE ENTRANCE SECTION OR “SES”. THE NECESSARY EQUIPMENT USUALLY CONSISTING OF CIRCUIT BREAKERS OR SWITCHES AND FUSES CONNECTED TO THE LOAD END OF SERVICE CONDUCTORS TO A BUILDING OR OTHER STRUCTURE, OR AN OTHERWISE DESIGNATED AREA, AND INTENDED TO CONSTITUTE THE MAIN CONTROL AND CUTOFF SUPPLY. 5.SUBSERVICE – THE NECESSARY EQUIPMENT CONNECTED TO THE LOAD SIDE OF SERVICE EQUIPMENT 6.SUB-PANEL OR PANEL – A TRADE TERM FOR SUBSERVICE PANELBOARDS OR LOAD CENTERS. 7.PREMISES WIRING – ALL ON-SITE WIRING FROM THE SERVICE POINT TO THE END UTILIZATION OUTLET. 8.FEEDERS – ALL CIRCUIT CONDUCTORS BETWEEN THE SERVICE EQUIPMENT AND THE FINAL OVERCURRENT DEVICE (CIRCUIT BREAKER). D.LOCATION 1.ELECTRICAL UTILITY: WHILE IN THE PLANNING STAGE AND BEFORE PERFORMING ANY WORK, CONTACT THE SERVING ELECTRICAL UTILITY REGARDING THE LOCATION OF THE SERVICE POINT, INSTALLATION REQUIREMENTS, EQUIPMENT TYPE AND REQUIRED CLEARANCES. 2.CLEARANCES IN FRONT OF THE SES AND SUB-PANELS NEC 110.26: (a)A MINIMUM THREE (3) FOOT DEEP LEVEL SPACE IN FRONT OF THE EQUIPMENT. NEC 110.26(A)(1). (b)MINIMUM 2’-6” (30”) WIDE SPACE OR WIDTH OF EQUIPMENT, WHICHEVER IS GREATER. NEC 110.26(A)(2). (c)EQUIPMENT DOORS MUST BE ABLE TO FULLY OPEN 90 DEGREES. NEC 110.26(A)(2). (d)MINIMUM 6’-6” HIGH OR TOP OF THE EQUIPMENT, WHICHEVER IS HIGHER. NEC 110.26(A)(3), 110.26(E). (e)THE ACCESS AND WORK SPACE SHALL NOT BE USED FOR STORAGE. NEC 110.26(B). 3.OUTDOOR/WATER/MOISTURE – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO WATER OR MOISTURE ON A REGULAR BASIS OR IN LARGE QUANTITIES, I.E. WHERE EXPOSED TO LAWN SPRINKLERS OR BELOW A ROOF SCUPPER. NEC 110.26(F). 4.VEHICULAR TRAFFIC – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO DAMAGE BY VEHICULAR TRAFFIC. NEC 110.26(F). 5.CLOTHES CLOSETS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN CLOTHES CLOSETS. NEC 240.24(D). 6.BATHROOMS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN BATHROOMS. NEC 240.24(E). 7.SEPARATE BUILDINGS – REFER TO NEC 225.30 PART B, 250.32, 250.50, 250.104 FOR REQUIRED DISCONNECTING MEANS, GROUNDING, AND BONDING. E.PERMIT AND PLAN REQUIREMENTS 1.SITE (PLOT) PLAN: PROVIDE A SIMPLE SITE PLAN (MINIMUM SCALE 1:40) INDICATING THE LOCATION OF EXISTING BUILDING(S), STRUCTURES, FENCES, POOLS, SPAS, ETC, AND THE LOCATION OR AREA WHERE THE SERVICE AND PANELBOARDS ARE TO BE INSTALLED. REFER TO THE SITE PLAN INCLUDED. 2.SINGLE LINE (FEEDER) DIAGRAM NEC 215.5. – DIAGRAM(S) ARE INCLUDED FOR REVIEW. 3.LOAD CALCULATIONS NEC 220 – PROVIDE ELECTRICAL LOAD CALCULATIONS FOR THE ELECTRICAL SERVICE (SES) AND EACH SUB-SERVICE PANEL TO BE INSTALLED. THE STANDARD OR OPTIONAL METHOD MAY BE USED. A COMPLETED OPTIONAL METHOD IS ATTACHED. EXAMPLES OF BOTH METHODS ARE LOCATED IN APPENDIX D OF THE NEC. F.INSPECTION REQUIREMENTS THE INSPECTION CARD LISTS IN DETAIL THE REQUIRED INSPECTIONS. THE FOLLOWING INSPECTIONS ARE FOR YOUR INFORMATION AND MAY VARY DEPENDING UPON THE INSTALLATION. 1.ROUGH ELECTRICAL 2.FINAL ELECTRIC 3.TEMPORARY ELECTRIC IN PERMANENT POSITION IS AN OPTION THAT CAN ALSO BE USED. AN APPLICATION AND REFUNDABLE DEPOSIT ARE REQUIRED. 4.FOR SERVICE SHUT DOWNS, PLEASE CALL INSPECTION SERVICES TO ARRANGE AN INSPECTION. Electric Panel Requirements / Calculations Basis of Design - Plumbing Calculation EXISTING RESIDENCE. EXISTING WATER PRESSURE AT HOSE BIB CLOSEST TO WATER METER MEASURES 65 PSI. FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 1 1/2"2.5 2.5 LAV SINK 1 1/2"1.5 1.5 KITCHEN SINK 1 1/2"1.5 1.5 COMBINATION TUB / SHOWER 1 1/2"4.0 4.0 DISHWASHER 1 1/2"1.5 1.5 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 17.5 PROPOSED ADU FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 2 1/2"2.5 5.0 LAV SINK 2 1/2"1.5 3.0 KITCHEN SINK 1 1/2"1.5 1.5 COMGO BATH/SHOWER 2 1/2"4.0 8.0 SHOWER 2 1/2"2.0 4.0 DISHWASHER 0 1/2"1.5 0.0 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 20.0 TOTAL (EXISTING RESIDENCE + ADU)37.5 PLUMBING CALCULATION NOTES: 1.THE EXISTING WATER METER IS A 3/4" SIZE WITH A 3/4" BUILDING SUPPLY LINE ON THE CUSTOMER SIDE OF THE METER. USING TABLE 610.3/610.4 FROM THE 2022 CA PLUMBING CODE TO DETERMINE PROPOSED AND EXISTING “WATER SUPPLY FIXTURE UNITS” (WSFU), THE COMBINATION OF EXISTING AND PROPOSED FIXTURE UNITS DOES NOT FALL WITHIN THE ACCEPTABLE RANGE, AND THEREFORE: 2.THE EXISTING 3/4" WATER METER WILL BE UPGRADED WITH A 1" WATER METER AND THE 3/4" BUILDING SUPPLY LINE SHALL BE UPGRADED WITH A 1" BUILDING SUPPLY LINE IN ORDER TO BE ADEQUATE FOR THE PROPOSED ADU. MEP3 Exterior Lighting Compliance Exterior Light Specs N.T.S.C CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 S0.1 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S0.2 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.1 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.2 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.3 Typical Details Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.4 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the ar chi t ec t. Ti t le t o these plans a nd speci f ications remains with cwa studios without prejudice. Visual con t ac t with t hes e plan s an d s peci f ic a t io ns shal l constitute prima face evidence of the acceptance of t h e s e re s t ri c t i o ns . c 20 20 c wa s t u di osproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.1 Foundation Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.2 Second Floor Framing Plan CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.3 Roof Framing Plan = "'-U') � 00a, '<I' "' "' -"' C: ;;.: C0 ·- '<I' Cl < "" C: u ;:;;­..,, • 0 1'--1 o e �-----,- C. I!! .!!! � .i � 00 Jj�---- '-' a, c:: ;;: 0 --'E C.C. "' Q) .lo:: N06J735 Q) > ·;::Cl ,-0""' M c) U") 0""' M C) VJ <'Cl E c..:i C) 0·a5 :I: VJ 0 :c C: 0� :::::s e en0 '- ·-a: Q) C: U) ...J ..c: M C: 0 I.D t'tl --, ,- U) revision: rllV dimipti111 PC CORREC'IDN legal stuff: :::, ..c u. ti 0 2 � 00 � WJ!ldate by 00.15.25 The use of these plans and specifications shall be rn.strlcted ta the use of the orlglrial site for wlllch they were prepared and publication thereof is expressly limtted to such use unless otherwise approved by the architect. Title to these plan3 and specifications remains with cwa studios without prejudice. Visual contact wllll these plans end apeclflcatlons shell constitute pr1ma face evidence of the acceptance of these restrictions c 2020 cwa studios sheet data: SWAjob no: CAD file:drawn by: plot dare: sheet title: 25053.01 JI/ 11.22.25 Structural Details sheet: S3.1 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S3.2 Structural Details Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 3/19/2026 By: Chris Allen, CWA Studios Date: Thursday, March 19, 2026 To: City of San Luis Obispo Community Development Department From: Chris Allen, Architect Re: 1st Code Compliance Review Response Letter Permit No. BLDG-2981-2025 New Attached ADU 619 Grove Street San Luis Obispo, CA 93401 CWA job: 197 The following are responses to the 1st plan review for the above referenced project; comments from the 1st plan review are provided below in half-tone for reference, and responses are provided in red font: California Code Check – Building Review 2022 CBC Comments Wastewater Offset v.2 Nico Gurney 1. Comment: Sheet AS1.1 - Correct sheet reference note 19 and 25 to reflect sewer pump configuration. Response: Sheet reference notes 19 and 25 have been updated accordingly. Notes now correctly reflect the sewer pump configuration. 2. Comment: Sheet AS1.1 - Modify note 16 to include replacement of onsite lateral. Response: Sheet reference note 16/AS1.1 has been updated to reflect the sewer lateral to be replaced. Note now reads, “existing sewer lateral to be replaced”. Fees v.2 Vanessa Nichols vnichols@slocity.org 8057817588 3. Comment: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Plan Check Response Christopher W. Allen, AIA – CWA Studios 1668 Sydney Street, San Luis Obispo, California 93401 Phone: 805-286-5186 Email: CWA.Arch@gmail.com Date Submitted: 3/19/2026 By: Chris Allen, CWA Studios Response: This shall be resolved prior to permit issuance. John Rourke (The property owner) has been in conversation with community development staff on resolution of this item. Final determination on how to proceed is pending and will be provided once it is available. 4. Comment: #3 Final fees pending response to comments and other department reviews. Response: Understood. Planning v.2 Ethan Estrada ejestrad@slocity.org 8057817576 5. Comment: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Response: Understood. 6. Comment: Upon further review, it's been noted that the site plan shows what appears to be another condenser on the south side of the proposed ADU that encroaches into the existing easement. This equipment is not shown on any other sheet in the plan set. Is this condenser supposed to be a part of this project? If it is, it will need to be relocated out of the existing easement. Post 2nd Submittal - this condenser is still shown on the site plan in the most recent submittal. Response: Thank you for catching this. Said condenser has been removed. The condenser location is now correctly shown to be along the northern building face. END BUILDING PERMIT Alt/Addition - ADU BLDG-2981-2025 Issuance Date: NOT ISSUEDBuilding & Safety Division • 919 Palm Street • San Luis Obispo, CA 93401-3218 001-056-029Project Address:619 Grove St , A Assessor's Parcel Number: Unit or Suite(s):A 920.00Square Footage: Legal Description:THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. TO CONSIST OF A 4-BEDROOM, 2-BATHROOM ADU. Project Description: Applicant: CWA Studios Chris Allen Business: (805) 286-5186 Owner: John Rourke Mobile: (( 2022Code Year:Stories : Not ProvidedFire Sprinklers:Motel Rooms:Dwelling Units: 2.00 Census:101 - Single Family Residence Construction Type:V-B Occupancy:Residential, 1 and 2 family dwellings (R-3) Valuation Group Type Sq. Ft Factor Valuation $168,000.00 Manual Fees Fee AmountFee Name Meter Service: Remove (.58"-1")$174.07 Adapter Cost (1" Service/.58"x.75" Meter)$72.00 SMIP (Residential)$25.96 C&D Recycling - UTIL $86.52 Inspection Fees - Alt/Addition ADU $4,968.00 Plan Check Fees - Alt/Addition ADU $4,968.00 Water Service: Plan Check - UTIL $695.25 Meter Service: Remove (.58"-1")$174.07 Final Inspection - SF Residential - PW $315.24 Stormwater - Minor Project - BLDG $534.57 Meter Service: Install (.75"-1")$174.07 Water Meter Cellular Data Transmitter - Equipment $131.84 Meter Cost (1")$241.02 Single Family Residential Final Inspection - ENG $258.53 Water Meter Cellular Data Transmitter - Install.$86.52 IT Surcharge $371.77 Green Building Fee $7.00 Dwelling Unit Construction Tax $182.31 Single Family Residential (Plan Review) -ENG $689.40 Building Plan Rev - Residential - Moderate $453.63 Total Fees:$14,609.77 Payments Date Receipt #Amount 1/7/26 $4,968.00 49,216-01-07-2026 3/31/26 $9,641.77 49,944-03-31-2026 Total Paid:$14,609.77 Contact Name Account BalanceTotal DebitsAccount Name Status Total Credits Plan Check Account Payment by Contact Total Account Balance: Balance Due:$0.00 Legal Declarations #2 IDENTIFY WHO WILL PERFORM THE WORK 2b – OWNER-BUILDER’S DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors’ State License Law for the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law is available upon request or athttp://www.leginfo.ca.gov/calaw.html. #3 IDENTIFY WORKERS’ COMPENSTATION COVERAGE AND LENDING AGENCY WARNING: Failure to secure workers’ compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in section 3706 of the labor code, interest, and attorney’s fees. I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if I should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. #4 DECLARATION BY CONSTRUCTION PERMIT APPLICANT By my signature below, I certify each of the following: I am the Property Owner. Signature of Contractor, Authorized Agent or Owner Date March 31, 2026 cnty oF san }-uls cnnspo Building & Safety Division r 919 Palm Street r San Luis Obispo' CA93401 r (805)781-7180 r (805) 781'1182Fax VE FO Dear PropertY Owner listing yourself as the builder of the property Building Permit APP|ication No improvements sPecified at \n/a ?rp nrnvir-lino,-rOrt WithY!C Ute this Owner-Bt-tilcJer Acknowl edgment and lnfo rmation Verification Form to make you aware of Your responsibilities and possible risk you may incur by having this Permit issued in Yo ur name as the Owner-Builder' We will not tssue a building permit until You have re official address indicated above approval of the permitting authority ad, initialed yo ur understanding of each Provis An agent of th e ouiner cannot execute this notic -//6\+ I aqree lhal, as lhe party iegally and financially responsible for this proposed construction activity requirements that govern Owner-Builders as well as employers I will abide by all appilcable laws and has been submttted in navnef ion, signed, and !'eturned this form to us at our e unleJs you, the property owner' obtain the prior ,4 DTRFCT''OfiJS: Refd atd initiat edil #ateme{st wn to sftTnify vre,tt wnffiwwr w ww iln68 tuttffiiosn" // ,//,--1. I understand a frequent pracilce of unricensed persons rs to have the property owner obtain an "owner-Builder'' building permit that erroneously fiipn"= that the property owner is providing hrs or her own rabor and material personally L as an owner-Builder, may be held liable and subject to serious flnancrai nsK for any injuries sustained by an unlicensed person and hls or her employees while working on my property My homeowner's insurance may not provrde coverage for those rnjuries. I am willfully acting al an owner-Builder and am aware of tre timits of my tnsurance coverage for )Dlwrcs to workers on mY ProPertY ? , r understand buirding permits are not required to be signed by properly owners unless lhey are responsible for the construction and are not hiring - a ticensed Contractor to assume this responsibility ,4 - j r .n.jerstand as an *owner-Builde/, r am the responsibre party of record on the permit. l-understand that I may protect myself from potential ' ffii,",;;;;;,;i;s a licensed contractor and having the permit filed in his or her name instead of my own -4.r'/ 4. I understand contractors are required by law to be licensed and bonded in california and to list their license numbers on permits and contracts' " /--- 41,,,';l,.T:ji",1rl;:H.s[;fJ1",ffffi::::: #,J;n:n:I;:'m.?:i:"#; l:Tl',"T"i"J1l!1,"i1[il'!1.'i3J:::l :1'" or mv construction is at ar'kL understand if I am considered an "emproye/' under state and federal law, I must register with the state and federal government' withhold payroll taxes, provide workers, compensation disability insurance, and contribute to unemployment compensation for each "employee " I also understand my failurg io abrde by these laws may subject me to serious financial risk' 4 I understand under california contractors, state License Law, an owner-guilder who builds single family residential structures cannot legally orrtd tnem with the intent to offer them for sale, unless a// work rs perform"J of li""n."d subcontractors Jnd the number of structures does not exceed four_within any calendar year, or all of the work is performed under contract wth a licensed general building Contractor' /ht ,noerstuno as an owner-Buirder if r selr the property for which this permit is issued, l,may be held liable for any flnanctal or personal injuries =r.ta"in"i;;;ii ,uo=uqr"nt owner(s) that result from any latent construction defects in the workmanship or materials /h ^^ J^-^r^,,o/ frnm rhp rnternal RevenLre Serytce, lhe United Statesz ' 9. lunderstand I may obtain more information regardrng my oblrgations as an 'employel'from lhe lnternal Revenue S' Small Business Administratron, the california Department of geneflt payments, and the california Diuirion of lndustrial Accidents l also understand I may contact the califomia contractors, State License Board (cSLB) at '1-g00,321-c sLB (2752) or www.cslb.ca.gov for more information about licensed contractors.2 4ft*^^aware of and consent to an owner-Builder building permit appried for in my name, and understand that I am the party legally and financially responsible for proposed construction actlvrty at the following project address -4//212-a6ne io notrfy lhe issuer of this form immediately of any additions, deletions, or changes to any of lhe rnformation I have provided on this f-orm. Licensed contractors are regulated by laws c"rign*c to protlct the punri.. rivou contract',iith,o*"on" who does not have a license the contractors,stale License Board may be unable to assist you with any finanoal toss you may sustain as a resuit of a complaint Your only remedy against un icensed contractors may be in civil couri. lt is also important for you to unierslani that if an unlicensed contractor or employee of thal individuar or fi.n rs rnlured while working on ycur prope.ty, you may be nerd riabte t'- Ju*ug"= lf you obtain a pe'mrt as owner-Builder and wish to hire contractors, you wrll be responsible for verifying whetheioi not those contractors ur" propJrly licensed and the status of their workers' compensatlon insurance coverage Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible ior issuing the permit. Note: A copy of nt'piirrt1 owier's d.1yer's license' form notarization' or ather verification acceptable to the agency is required to be present&-In"i the permit is issued to verify the property ownefs signature. Print Name of ProPerty Owner Signature Date = SAN LUIS COASTAL UNIFIED SCHOOT DISTRICT 1500 Lizzie St., San Luis Obispo CA 93401 Fiscal Services Department (805) 549-7273 LEVEL ONE FEES Received From: John Rourke Address: 5L9 Grove St., A Phone:8O5"440,4978 Sum of: FourThousand Seven Hundred Fifty Six Dollars and Forty Cents Property Address:619 Grove St., A No Fees Due Reason:Property Type:IC RESIDENTIAL T COMMERICAL T STORAGE Total Fee: S/sq.ft.920 x 5.L7 sq.ft.- S 4,756.40 Method of Payment: r COUNTY CHECK le CITY Name: San Luis Obispo Check/M.O.#:3tq L Permit #: BLDG-298L-2025 To D Ev ELo P E R/owfu m/o esrc n et: you ARE HEREBr NOTIFIED THAT yOU HAVE NtNETy (90) DAYS FROM THE DATE OF PAYMENT OF THE FEES tDENTtFtED HERETN TO FILE A PROTEST AGAINST THE IMPOSITION OF THESE FEES PURSUANT TO GOW, CODE SECIION 66020 IN'TIAL District Signature ]3a.zb Certificate of payment expires 6 months from this date PERMIT CORRECTIONS REPORT (BLDG-2981-2025) FOR CITY OF SAN LUIS OBISPO PARCEL:001-056-029PERMIT ADDRESS:619 Grove St, A San Luis Obispo, CA 93401 APPLICATION DATE:01/07/2026 EXPIRATION DATE: SQUARE FEET: 920.00 VALUATION:$168,000.00 DESCRIPTION:THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. TO CONSIST OF A 4-BEDROOM, 2-BATHROOM ADU. CONTACTS NAME COMPANY ADDRESS Applicant Chris Allen CWA Studios 1668 Sydney Street San Luis Obispo, CA 93401 Owner John Rourke Alt/Add - ADU REVIEW ITEM STATUS REVIEWER Addressing v.1 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Addressing Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #1 Address assigned to new ADU is 619 A Grove Street. Please update all plan sheets to reflect the newly assigned address. Addressing v.2 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Ready for Action General - Addressing Correction: Administration - Vanessa Nichols (2/20/26) - Resolved Comments: #1 Address assigned to new ADU is 619 A Grove Street. Please update all plan sheets to reflect the newly assigned address. Arborist v.1 Walter Gault email: wgault@slocity.org Needs Resubmit General - Arborist Arborist v.2 Walter Gault email: wgault@slocity.org Needs Resubmit General - Arborist Correction: Urban Forestry - Walter Gault (2/24/26) - Not Resolved Comments: Per Uniform Design Criteria 1010 3.1.23 Street Trees, a minimum of one street tree shall be installed per 35 feet of street frontage for any commercial or residential building permit addition or new dwelling unit, unless City Arborist determines that the site cannot accommodate a new tree. Street trees may be grouped if necessary to avoid conflict with other improvements. Please select a street tree from the City Approved Tree List (Zone 1 tree species), and if in a Fire Hazard Severity Zone, the City of SLO Zone 1 Defensible Space Tree List. Street trees may be planted in front yards to satisfy the requirement. Corrective Action: Please provide a landscaping plan that satisfies the Uniform Design Criteria 1010 3.1.23 Street Trees requirement. Plan shall include tree species selected from Engineering Standard (8010) and Zone 1 category, tree size, location, City Engineering Standards for Tree Planting (8210, 8220, 8250) and an irrigation detail (8670 Tree Bubbler or 8660 Drip Irrigation). Correction: Urban Forestry - Walter Gault (2/24/26) - Not Resolved Comments: Walter Gault, City Arborist, 805-781-7578, wgault@slocity.org Correction: Urban Forestry - Walter Gault (2/24/26) - Not Resolved Comments: If a tree protection and monitoring plan is necessary or a tree removal application and compensatory replanting plan is required, please provide a project arborist to oversee all arboriculture activities. Corrective Action: Please provide a tree protection plan on demo, grading and building permit plan submittals that satisfies Specification 77-1.03A(2) and identifies the location, type, trunk and canopy diameter of all trees onsite (and adjacent offsite) and explains the likelihood of tree retention (based on impact to the critical root zone of trees on- and offsite). An Arborist Report providing further information may be required. Arborist v.3 Walter Gault email: wgault@slocity.org Ready for Action General - Arborist Correction: Urban Forestry - Walter Gault (3/5/26) - Resolved Comments: Walter Gault, City Arborist, 805-781-7578, wgault@slocity.org Correction: Urban Forestry - Walter Gault (3/5/26) - Resolved Comments: Per Uniform Design Criteria 1010 3.1.23 Street Trees, a minimum of one street tree shall be installed per 35 feet of street frontage for any commercial or residential building permit addition or new dwelling unit, unless City Arborist determines that the site cannot accommodate a new tree. Street trees may be grouped if necessary to avoid conflict with other improvements. Please select a street tree from the City Approved Tree List (Zone 1 tree species), and if in a Fire Hazard Severity Zone, the City of SLO Zone 1 Defensible Space Tree List. Street trees may be planted in front yards to satisfy the requirement. Corrective Action: Please provide a landscaping plan that satisfies the Uniform Design Criteria 1010 3.1.23 Street Trees requirement. Plan shall include tree species selected from Engineering Standard (8010) and Zone 1 category, tree size, location, City Engineering Standards for Tree Planting (8210, 8220, 8250) and an irrigation detail (8670 Tree Bubbler or 8660 Drip Irrigation). Correction: Urban Forestry - Walter Gault (3/5/26) - Resolved Comments: If a tree protection and monitoring plan is necessary or a tree removal application and compensatory replanting plan is required, please provide a project arborist to oversee all arboriculture activities. Corrective Action: Please provide a tree protection plan on demo, grading and building permit plan submittals that satisfies Specification 77-1.03A(2) and identifies the location, type, trunk and canopy diameter of all trees onsite (and adjacent offsite) and explains the likelihood of tree Page 1 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) retention (based on impact to the critical root zone of trees on- and offsite). An Arborist Report providing further information may be required. Building (True North) v.1 Angelica Tellez email: atellez@slocity.org Needs Resubmit Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E.If you have any questions regarding the comments below, please contact Yazeed Hassan - via email yazeedh@tncservices.com or telephone (562) 733-8030. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A1.Sheet T1.0: Revise occupancy to be R-3 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A2.Sheet T1.0: Revise sheet S3.3 on the index to be S3.2 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A3.Sheet A2.1: Revise door 3 for the bedroom and the bathroom on the first floor to have a width of 3’ to provide 32” clear width for per Aging-in-place requirements. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A4.Sheet A2.1: Detail A/A2.1 referenced on plans does not appear to be provided. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A5.Sheet A5.2: fire rated wall details are not coordinated; sections show gypsum board on the exterior side and fire rated wall details show stucco on the exterior side of the wall. Please provide an approved fire-rated construction detail with basis of approval (i.e., UL design, G.A. file #) for the rated wall and cross reference onto the plans. CRC Table R302.1(1). Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A6.Sheet A3.2: Provide construction details for the exterior stairs in accordance with CRC 311. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A7.Sheet A4.1: Note 4 refers to detail A and B that appear to be missing. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A8.Sheet MEP1: Provide carbon monoxide alarm in the area leading to bedroom 202. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: M1.Sheet MEP1: Show the location of the bathroom and kitchen exhaust duct termination. Air ducts shall exhaust 3’-0” from property line and 3’-0” from openings into the building. CMC 504.5. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E1.Sheet MEP1: Specify exterior receptacle outlets to be provided with waterproofing cover. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E2.Sheet MEP1: Show the location and size of electrical panel. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: P1.Sheet MEP1: Show the size and location of sewer lateral. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: G1.Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: T1.Sheet T1.0: List all HERS inspection features and special features required. Please coordinate with the Energy Report. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: T2.Sheet A4.1: In the cross section of the building identify the insulation with the respective R-values at the walls, attic/ceiling, floors, and etc. per the Title-24 Certificate of Compliance Form. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S1.Sheet A1.3: Provide calculations and details. Guards and handrails shall be designed to resist a load of 200 psf applied in any direction at the top and to transfer this load through the support structure. CRC R301.5 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S2.Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S3.Sheet S2.1: Detail 1/S3.1 is referenced for continuous footing along gridline 19Y which does not appear to be accurate. Civil and elevation sheets show ADU to be built on sloped land. Please provide accurate details and calculations. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S4.Sheet S2.2: The ridge board shall have bigger thickness than the rafters connected to it. Revise rafters to be 2x10 or ridge board to be 2x14. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S5.Sheet S2.2: Provide framing and foundation details for exterior stairs. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S6.Sheet S2.1: Specify the header size above each exterior opening. Building (True North) v.2 Angelica Tellez email: atellez@slocity.org Needs Resubmit Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E.If you have any questions regarding the comments below, please contact Yazeed Hassan - via email yazeedh@tncservices.com or telephone (562) 733-8030. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A1.Sheet T1.0: Revise occupancy to be R-3 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A2.Sheet T1.0: Revise sheet S3.3 on the index to be S3.2 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A3.Sheet A2.1: Revise door 3 for the bedroom and the bathroom on the first floor to have a width of 3’ to provide 32” clear width for per Aging-in-place requirements. Page 2 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A4.Sheet A2.1: Detail A/A2.1 referenced on plans does not appear to be provided. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A5.Sheet A5.2: fire rated wall details are not coordinated; sections show gypsum board on the exterior side and fire rated wall details show stucco on the exterior side of the wall. Please provide an approved fire-rated construction detail with basis of approval (i.e., UL design, G.A. file #) for the rated wall and cross reference onto the plans. CRC Table R302.1(1). Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A6.Sheet A3.2: Provide construction details for the exterior stairs in accordance with CRC 311. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A7.Sheet A4.1: Note 4 refers to detail A and B that appear to be missing. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A8.Sheet MEP1: Provide carbon monoxide alarm in the area leading to bedroom 202. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: M1.Sheet MEP1: Show the location of the bathroom and kitchen exhaust duct termination. Air ducts shall exhaust 3’-0” from property line and 3’-0” from openings into the building. CMC 504.5. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E1.Sheet MEP1: Specify exterior receptacle outlets to be provided with waterproofing cover. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E2.Sheet MEP1: Show the location and size of electrical panel. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: P1.Sheet MEP1: Show the size and location of sewer lateral. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Not Resolved Comments: G1.Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Corrective Action: PC2: Comment remains. Provide updated checklist. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: T1.Sheet T1.0: List all HERS inspection features and special features required. Please coordinate with the Energy Report. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: T2.Sheet A4.1: In the cross section of the building identify the insulation with the respective R-values at the walls, attic/ceiling, floors, and etc. per the Title-24 Certificate of Compliance Form. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S1.Sheet A1.3: Provide calculations and details. Guards and handrails shall be designed to resist a load of 200 psf applied in any direction at the top and to transfer this load through the support structure. CRC R301.5 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Not Resolved Comments: S2.Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Corrective Action: PC2: No geotechnical report is provided. Remove the slab on grade note on sheet S2.1 referring to a geotechnical report. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S3.Sheet S2.1: Detail 1/S3.1 is referenced for continuous footing along gridline 19Y which does not appear to be accurate. Civil and elevation sheets show ADU to be built on sloped land. Please provide accurate details and calculations. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S4.Sheet S2.2: The ridge board shall have bigger thickness than the rafters connected to it. Revise rafters to be 2x10 or ridge board to be 2x14. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S5.Sheet S2.2: Provide framing and foundation details for exterior stairs. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S6.Sheet S2.1: Specify the header size above each exterior opening. Building (True North) v.3 Angelica Tellez email: atellez@slocity.org Ready for Action Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E.If you have any questions regarding the comments below, please contact Yazeed Hassan - via email yazeedh@tncservices.com or telephone (562) 733-8030. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A1.Sheet T1.0: Revise occupancy to be R-3 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A2.Sheet T1.0: Revise sheet S3.3 on the index to be S3.2 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A3.Sheet A2.1: Revise door 3 for the bedroom and the bathroom on the first floor to have a width of 3’ to provide 32” clear width for per Aging-in-place requirements. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A4.Sheet A2.1: Detail A/A2.1 referenced on plans does not appear to be provided. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A5.Sheet A5.2: fire rated wall details are not coordinated; sections show gypsum board on the exterior side and fire rated wall details show stucco on the exterior side of the wall. Please provide an approved fire-rated construction detail with basis of approval (i.e., UL design, G.A. file #) for the rated wall and cross reference onto the plans. CRC Table R302.1(1). Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A6.Sheet A3.2: Provide construction details for the exterior stairs in accordance with CRC 311. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A7.Sheet A4.1: Note 4 refers to detail A and B that appear to be missing. Page 3 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A8.Sheet MEP1: Provide carbon monoxide alarm in the area leading to bedroom 202. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: M1.Sheet MEP1: Show the location of the bathroom and kitchen exhaust duct termination. Air ducts shall exhaust 3’-0” from property line and 3’-0” from openings into the building. CMC 504.5. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E1.Sheet MEP1: Specify exterior receptacle outlets to be provided with waterproofing cover. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E2.Sheet MEP1: Show the location and size of electrical panel. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: P1.Sheet MEP1: Show the size and location of sewer lateral. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: T1.Sheet T1.0: List all HERS inspection features and special features required. Please coordinate with the Energy Report. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: T2.Sheet A4.1: In the cross section of the building identify the insulation with the respective R-values at the walls, attic/ceiling, floors, and etc. per the Title-24 Certificate of Compliance Form. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S1.Sheet A1.3: Provide calculations and details. Guards and handrails shall be designed to resist a load of 200 psf applied in any direction at the top and to transfer this load through the support structure. CRC R301.5 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S3.Sheet S2.1: Detail 1/S3.1 is referenced for continuous footing along gridline 19Y which does not appear to be accurate. Civil and elevation sheets show ADU to be built on sloped land. Please provide accurate details and calculations. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S4.Sheet S2.2: The ridge board shall have bigger thickness than the rafters connected to it. Revise rafters to be 2x10 or ridge board to be 2x14. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S5.Sheet S2.2: Provide framing and foundation details for exterior stairs. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S6.Sheet S2.1: Specify the header size above each exterior opening. Correction: Building Code Compliance - Angelica Tellez (3/5/26) - Resolved Comments: G1.Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Corrective Action: PC2: Comment remains. Provide updated checklist. Correction: Building Code Compliance - Angelica Tellez (3/5/26) - Resolved Comments: S2.Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Corrective Action: PC2: No geotechnical report is provided. Remove the slab on grade note on sheet S2.1 referring to a geotechnical report. Code Enforcement General v.1 Steve Sheats email: ssheats@slocity.org Needs Resubmit Code Enforcement General Code Enforcement General v.2 Steve Sheats email: ssheats@slocity.org Ready for Action Code Enforcement General Fees v.1 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Fees Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #3 Final fees pending response to comments and other department reviews. Fees v.2 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Fees Correction: Administration - Vanessa Nichols (2/20/26) - Not Resolved Comments: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Correction: Administration - Vanessa Nichols (2/20/26) - Not Resolved Comments: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. PARTIAL COMMENT REMAINS: Plumbing calc needs to reflect the upgrade of water meter and service. Sheet Reference Note #9. Sheet S1.1, needs to be update to reflect the water meter being upgraded. Correction: Administration - Vanessa Nichols (2/20/26) - Not Resolved Comments: #3 Final fees pending response to comments and other department reviews. Fees v.3 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Fees Correction: Administration - Vanessa Nichols (3/5/26) - Not Resolved Comments: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Page 4 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Correction: Administration - Vanessa Nichols (3/5/26) - Resolved Comments: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. PARTIAL COMMENT REMAINS: Plumbing calc needs to reflect the upgrade of water meter and service. Sheet Reference Note #9. Sheet S1.1, needs to be update to reflect the water meter being upgraded. Correction: Administration - Vanessa Nichols (3/5/26) - Not Resolved Comments: #3 Final fees pending other department reviews. No Action Required. Planning v.1 Ethan Estrada email: ejestrad@slocity.org Needs Resubmit General - Planning Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Resolved Comments: Ethan Estrada (Asst. Planner) | ejestrad@slocity.org | (805) 781-7576 Corrective Action: Contact Info Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Corrective Action: Process Tracking Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Trees appear to possibly be impacted by your project proposal and will require review by the City Arborist. An arborist report may be required. Corrective Action: Trees Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Provide expanded calculations/confirm the existing lot coverage for this property on the title sheet. Corrective Action: Lot Coverage Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Title sheet states one parking space is provided in the driveway. On the site plan, note the location and dimensions of this parking space - keep in mind that parking may not be located in the front yard setback. Corrective Action: Parking Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: The MEP plan depicts a condenser on the north side of the proposed addition, but the site plan and elevations do not depict this mechanical equipment. Ensure this equipment is depicted consistently throughout the plan set - note the distance between the condenser and the north property line on the site plan. Corrective Action: Proposed Condenser Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.080, the height of structures on properties with an average cross-parcel slope less than 16% shall be measured from the average natural grade of the portion of the parcel that the proposed structure is to be built on. Adjust the height measurements provided on the elevations so that they are measured from average natural grade. Corrective Action: Avg. Natural Grade Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: On the elevations, note the direction from which the elevations are being viewed from. Corrective Action: Elevation Labels Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: MEP plan indicates that there will be exterior lighting. Ensure that such lighting is also depicted in the elevations. Corrective Action: Elevations & Lighting Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Exterior Light Fixtures Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Lighting Levels Planning v.2 Ethan Estrada email: ejestrad@slocity.org Needs Resubmit General - Planning Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Resolved Comments: Ethan Estrada (Asst. Planner) | ejestrad@slocity.org | (805) 781-7576 Corrective Action: Contact Info Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Not Resolved Comments: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Corrective Action: Process Tracking Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Trees appear to possibly be impacted by your project proposal and will require review by the City Arborist. An arborist report may be required. Corrective Action: Trees Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Provide expanded calculations/confirm the existing lot coverage for this property on the title sheet. Corrective Action: Lot Coverage Page 5 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Title sheet states one parking space is provided in the driveway. On the site plan, note the location and dimensions of this parking space - keep in mind that parking may not be located in the front yard setback. Corrective Action: Parking Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: The MEP plan depicts a condenser on the north side of the proposed addition, but the site plan and elevations do not depict this mechanical equipment. Ensure this equipment is depicted consistently throughout the plan set - note the distance between the condenser and the north property line on the site plan. Corrective Action: Proposed Condenser Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Per SLOMC 17.70.080, the height of structures on properties with an average cross-parcel slope less than 16% shall be measured from the average natural grade of the portion of the parcel that the proposed structure is to be built on. Adjust the height measurements provided on the elevations so that they are measured from average natural grade. Corrective Action: Avg. Natural Grade Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: On the elevations, note the direction from which the elevations are being viewed from. Corrective Action: Elevation Labels Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: MEP plan indicates that there will be exterior lighting. Ensure that such lighting is also depicted in the elevations. Corrective Action: Elevations & Lighting Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Exterior Light Fixtures Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Lighting Levels Correction: Planning and Zoning Compliance - Ethan Estrada (3/3/26) - Not Resolved Comments: Upon further review, it's been noted that the site plan shows what appears to be another condenser on the south side of the proposed ADU that encroaches into the existing easement. This equipment is not shown on any other sheet in the plan set. Is this condenser supposed to be a part of this project? If it is, it will need to be relocated out of the existing easement. Corrective Action: Proposed Mechanical Equipment in Easement Planning v.3 Ethan Estrada email: ejestrad@slocity.org Needs Resubmit General - Planning Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Resolved Comments: Ethan Estrada (Asst. Planner) | ejestrad@slocity.org | (805) 781-7576 Corrective Action: Contact Info Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Trees appear to possibly be impacted by your project proposal and will require review by the City Arborist. An arborist report may be required. Corrective Action: Trees Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Provide expanded calculations/confirm the existing lot coverage for this property on the title sheet. Corrective Action: Lot Coverage Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Title sheet states one parking space is provided in the driveway. On the site plan, note the location and dimensions of this parking space - keep in mind that parking may not be located in the front yard setback. Corrective Action: Parking Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: The MEP plan depicts a condenser on the north side of the proposed addition, but the site plan and elevations do not depict this mechanical equipment. Ensure this equipment is depicted consistently throughout the plan set - note the distance between the condenser and the north property line on the site plan. Corrective Action: Proposed Condenser Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Per SLOMC 17.70.080, the height of structures on properties with an average cross-parcel slope less than 16% shall be measured from the average natural grade of the portion of the parcel that the proposed structure is to be built on. Adjust the height measurements provided on the elevations so that they are measured from average natural grade. Corrective Action: Avg. Natural Grade Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: On the elevations, note the direction from which the elevations are being viewed from. Corrective Action: Elevation Labels Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: MEP plan indicates that there will be exterior lighting. Ensure that such lighting is also depicted in the elevations. Corrective Action: Elevations & Lighting Correction: Planning and Zoning Compliance - Ethan Estrada (3/5/26) - Not Resolved Page 6 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Comments: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Corrective Action: Process Tracking Correction: Planning and Zoning Compliance - Ethan Estrada (3/5/26) - Resolved Comments: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Exterior Light Fixtures Correction: Planning and Zoning Compliance - Ethan Estrada (3/5/26) - Resolved Comments: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Lighting Levels Correction: Planning and Zoning Compliance - Ethan Estrada (3/5/26) - Not Resolved Comments: Upon further review, it's been noted that the site plan shows what appears to be another condenser on the south side of the proposed ADU that encroaches into the existing easement. This equipment is not shown on any other sheet in the plan set. Is this condenser supposed to be a part of this project? If it is, it will need to be relocated out of the existing easement. Post 2nd Submittal - this condenser is still shown on the site plan in the most recent submittal. Corrective Action: Proposed Mechanical Equipment in Easement Private Sewer Lateral v.1 Ready for Action Private Sewer Lateral Inspection requirements (per Muni Code section 13.08.395) Private Sewer Lateral v.2 Ryan Beech email: rbeech@slocity.org Ready for Action Private Sewer Lateral Inspection requirements (per Muni Code section 13.08.395) Public Works Permit Review v.1 Emma LaPlante email: elaplant@slocity.org Needs Resubmit General - Public Works Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 0.Emma Laplante – elaplant@slocity.org or 805-781-7199 Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 1.Include the following note under Standard Public Works Notes a.All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 2.These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 3.Update Standard Public Works Notes to reference the December 2025 City standard Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 4.A System certification is required from the engineer of record prior to final inspection approvals. The engineer shall certify that the drainage and stormwater system components have been inspected and are in general conformance with the drainage report, system design, and the approved plans, including all final elevations, component sizing, detention basins, parking lot detention curb elevations, drainage piping, inlets, weir elevations, and orifices Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 5.No project type is checked on the Stormwater Control Plan for Post Construction Requirements, please revise. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 6.Clarify the Proposed drainage strategy a.If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. c.Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain d.Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 7.Revise Plans as follows: a.For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. b.Show existing utility on all sheets with a line, not just a callout. c.Clearly show the drive approach and driveway on the plans. d.There are abbreviations used that are not included in the legend e.A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed f.Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g.The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. h.Show the material of the existing utility. See the attached Utility grid maps for reference. i.Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Page 7 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Comments: 8.The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Public Works Permit Review v.2 Emma LaPlante email: elaplant@slocity.org Needs Resubmit General - Public Works Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 0.Emma Laplante – elaplant@slocity.org or 805-781-7199 Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 1.Include the following note under Standard Public Works Notes a.All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 2.These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 3.Update Standard Public Works Notes to reference the December 2025 City standard Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 4.A System certification is required from the engineer of record prior to final inspection approvals. The engineer shall certify that the drainage and stormwater system components have been inspected and are in general conformance with the drainage report, system design, and the approved plans, including all final elevations, component sizing, detention basins, parking lot detention curb elevations, drainage piping, inlets, weir elevations, and orifices Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 5.No project type is checked on the Stormwater Control Plan for Post Construction Requirements, please revise. Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 6.Clarify the Proposed drainage strategy a.If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. Resolved b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. Comment Remain: Water shall not be pumped into the street. Invert/location needs to be revised to allow for gravity flow into the street. c.Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain. Resolved d.Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Resolved Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 7.Revise Plans as follows: a.For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. Resolved b.Show existing utility on all sheets with a line, not just a callout. c.Clearly show the drive approach and driveway on the plans. Comment Remains: Through additional research it seems like the drive approach is being converted to curb under BLDG-1030-2023/ENCR-0189-2026. In addition is also appears that the Majority of the driveway will be replace with concrete under the same permit. Please revise the plans to reflect the changes under the above listed permit. d.There are abbreviations used that are not included in the legend. Resolved e.A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed. Comment remains: TOPO shows brick pavers where the ADU is going but there are no call outs to remove them. Please clarify f.Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g.The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. Comment remain: plans need to reflect the improvement outline in BLDG-1030-2023/ENCR-0189-2026 h.Show the material of the existing utility. See the attached Utility grid maps for reference. Resolved i.Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach. Resolved Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 8.The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Resolved: See utility comments Correction: Engineering Standards Compliance - Emma LaPlante (2/27/26) - Not Resolved Comments: 9.Additional Plan Comments a.There is a discrepancy in the property line between the approved build plans for Parcel 1 (back parcel) and current plans for Parcel 2. Provide verification from the survey on which property line location is correct. Public Works Permit Review v.3 Emma LaPlante email: elaplant@slocity.org Ready for Action General - Public Works Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 3.Update Standard Public Works Notes to reference the December 2025 City standard Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 4.A System certification is required from the engineer of record prior to final inspection approvals. The engineer shall certify that the drainage and stormwater system components have been inspected and are in general conformance with the drainage report, system design, and the approved plans, including all final elevations, component sizing, detention basins, parking lot detention curb elevations, drainage piping, inlets, weir elevations, and orifices Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Page 8 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Comments: 5.No project type is checked on the Stormwater Control Plan for Post Construction Requirements, please revise. Correction: Engineering Standards Compliance - Emma LaPlante (3/5/26) - Resolved Comments: 0.Emma Laplante – elaplant@slocity.org or 805-781-7199 Correction: Engineering Standards Compliance - Emma LaPlante (3/5/26) - Resolved Comments: 1.Include the following note under Standard Public Works Notes a.All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Correction: Engineering Standards Compliance - Emma LaPlante (3/5/26) - Resolved Comments: 2.These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Correction: Engineering Standards Compliance - Emma LaPlante (3/5/26) - Resolved Comments: 6.Clarify the Proposed drainage strategy a.If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. Resolved b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. Comment Remain: Water shall not be pumped into the street. Invert/location needs to be revised to allow for gravity flow into the street. c.Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain. Resolved d.Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Resolved Correction: Engineering Standards Compliance - Emma LaPlante (3/5/26) - Resolved Comments: 7.Revise Plans as follows: a.For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. Resolved b.Show existing utility on all sheets with a line, not just a callout. c.Clearly show the drive approach and driveway on the plans. Comment Remains: Through additional research it seems like the drive approach is being converted to curb under BLDG-1030-2023/ENCR-0189-2026. In addition is also appears that the Majority of the driveway will be replace with concrete under the same permit. Please revise the plans to reflect the changes under the above listed permit. d.There are abbreviations used that are not included in the legend. Resolved e.A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed. Comment remains: TOPO shows brick pavers where the ADU is going but there are no call outs to remove them. Please clarify f.Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g.The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. Comment remain: plans need to reflect the improvement outline in BLDG-1030-2023/ENCR-0189-2026 h.Show the material of the existing utility. See the attached Utility grid maps for reference. Resolved i.Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach. Resolved Correction: Engineering Standards Compliance - Emma LaPlante (3/5/26) - Resolved Comments: 8.The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Resolved: See utility comments Correction: Engineering Standards Compliance - Emma LaPlante (3/5/26) - Resolved Comments: 9.Additional Plan Comments a.There is a discrepancy in the property line between the approved build plans for Parcel 1 (back parcel) and current plans for Parcel 2. Provide verification from the survey on which property line location is correct. Recycling v.1 Rachelle Paris email: rparis@slocity.org Ready for Action General - Recycling Utilities Project Manager (Building) v.2 Nico Gurney email: ngurney@slocity.org Needs Resubmit General - Utilities Correction: Utilities - Nico Gurney (2/27/26) - Not Resolved Comments: Sheet AS1.0: Does sewer lateral from parcel one also feed the proposed sewer pump? Utilities Project Manager (Building) v.3 Nico Gurney email: ngurney@slocity.org Ready for Action General - Utilities Correction: Utilities - Nico Gurney (3/5/26) - Resolved Comments: Sheet AS1.0: Does sewer lateral from parcel one also feed the proposed sewer pump? Wastewater Offset v.2 Nico Gurney email: ngurney@slocity.org Needs Resubmit Wastewater Offset Wastewater Offset v.3 Nico Gurney email: ngurney@slocity.org Needs Resubmit Wastewater Offset Correction: Utilities - Nico Gurney (3/13/26) - Not Resolved Comments: Sheet AS1.1 - Correct sheet reference note 19 and 25 to reflect sewer pump configuration. Correction: Utilities - Nico Gurney (3/13/26) - Not Resolved Comments: Sheet AS1.1 - Modify note 16 to include replacement of onsite lateral. Page 9 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) eReview Session for Alt/Add - ADU v.1 FILES:25053 - 619 Grove St Calculations 12.01.25.pdf 619 Grove Street - 1st Building Submittal - 25.1222.pdf Construction and Demolition Recycling and Waste Pl.pdf GroveT24OFFICIL.pdf Soils Waiver Application.pdf stormwatercontrolplan.pdf waterpollutioncontrolplan.pdf REVIEWER MARKUP DATE/TIME FILE NAME PG # yhassan R-3 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan ADD HERS SPECIAL FEATURES 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan GROVE ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan MONTEREY ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan MILL ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan GRAND AVE 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan HILLCREST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan 101 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan S3.2 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan FILL OUT 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 2 yhassan FILL OUT 01/16/2026 7:10 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 3 yhassan SHOW CLEARANCES 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-10 3/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 Page 10 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan A122.Newly constructed dwelling units including detached ADUs are required to comply with Aging-In-Place requirements in accordance with CRC R327. Address the following comments: a)At least one bathroom and one bedroom shall be provided with a net clear opening of not less than 32 inches. Per CRC.R327.1.3 b)At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least one bathroom on the floor above shall comply with this section. i)Specify the reinforcement to be solid lumber and not less than 2X8. ii)The reinforcement shall be located between 32” and 39 ¼” above the finished floor. iii)Specify the water closet reinforcement to be installed on both side walls of the fixture, or one side wall and the back wall. (1)Where the water closet is not located adjacent to the side wall, grab bar reinforcement for a ground-mounted installation is acceptable. iv)Specify the shower reinforcement shall be continuous where wall framing is provided. v)Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6” above the bathtub rim. c)Note on plans: Electrical receptacle outlets, switches and controls intended to be used by occupants shall be located no more than 48” measured from the top of the outlet box and not less than 15” measured from the bottom of the outlet box above the finish floor. d)Specify doorbell controls to not exceed 48” above exterior floor, measured from the top of the doorbell button assembly. 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan Provide guardrail details and calculations 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan SHOW CLEARANCES 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 2'-6"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-10 3/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan SHOW LOCATION AND SIZE OF ATTIC 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-4 1/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 2'-6"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-4 1/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan R-VALUES?01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 12 yhassan PROVIDE STC MINIMUM 50 RATING FOR FIRE SEPARATION 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan L = 7'-2 1/2"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan PROVIDE STC MINIMUM 50 RATING FOR FIRE SEPARATION 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan L = 7'-2 1/2"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan SHOW DUCT TERMINATION 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 Page 11 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan MS 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 yhassan VACANCY / DIMMING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 0X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STEEL SHOULD BE HELD IN PLACE BY STIRRUPS AT APPROPRIATE SPACING TO ENSURE PROPER POSITIONING OF THE STEEL (SEE WRI DESIGN OF SLAB-ON-GROUND FOUNDATIONS AND ACI 318, SECTION 26.6.6 - PLACING REINFORCEMENT). 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Tel. (805) 548-8600 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan U.N.O. CONCRETE SLAB ON GRADE TO BE PER DETAIL 6/S3.1. REFER 6/S3.1. REFER . REFER TO PROJECT GEOTECHNICAL REPORT FOR ADDITIONAL REQUIREMENTS 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan J 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Size 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan TYP.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 22'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates shearwall type designation per schedule 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan REVISE NOTE AS NO GEOTECHNICAL REPORT WAS PROVIDED. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Fax (805) 548-8601 Fax (805) 548-8601 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 12 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan P 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan REFER TO DETAIL 7/S1.2 7/S1.2 FOR TYPICAL HEADER SIZES U.N.O. ON PLAN 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan UNDERPIN EXISTING FOOTING w/ SLURRY TO BOTTOM OF (N) FOOTING AT THE TIME OF (N) FOOTING CONSTRUCTION. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan OUTLINE OF EXISTING BUILDING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Wood Posts 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Edge 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXP. 9/2026 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan FOUNDATION KEYED NOTES :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan UNDERPIN EXISTING FOOTING w/ SLURRY 2'-0" MIN. BELOW BOTTOM OF (E) FOOTING PRIOR TO (N) FOOTING CONSTRUCTION. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan DBL. STUD OR DBL. KING STUD (4)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Arrow indicates anticipated side of wall to shear 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-11 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan U 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan G 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear Wall Schedule (SW)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates strap or holdown each end of shear wall 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan BALLOON FRAME WALLS TO ROOF AT STAIR WELL 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shaded region indicates shear wall 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 13 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 555 Chorro St., Ste. A1 San Luis Obispo, CA 9340555 Chorro St., Ste. A1 San Luis Obispo, CA 934055 Chorro St., Ste. A1 San Luis Obispo, CA 93405 Chorro St., Ste. A1 San Luis Obispo, CA 93405Chorro St., Ste. A1 San Luis Obispo, CA 93405horro St., Ste. A1 San Luis Obispo, CA 93405orro St., Ste. A1 San Luis Obispo, CA 93405rro St., Ste. A1 San Luis Obispo, CA 93405ro St., Ste. A1 San Luis Obispo, CA 93405o St., Ste. A1 San Luis Obispo, CA 93405 St., Ste. A1 San Luis Obispo, CA 93405St., Ste. A1 San Luis Obispo, CA 93405t., Ste. A1 San Luis Obispo, CA 93405., Ste. A1 San Luis Obispo, CA 93405, Ste. A1 San Luis Obispo, CA 93405 Ste. A1 San Luis Obispo, CA 93405Ste. A1 San Luis Obispo, CA 93405te. A1 San Luis Obispo, CA 93405e. A1 San Luis Obispo, CA 93405. A1 San Luis Obispo, CA 93405 A1 San Luis Obispo, CA 93405A1 San Luis Obispo, CA 934051 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405San Luis Obispo, CA 93405an Luis Obispo, CA 93405n Luis Obispo, CA 93405 Luis Obispo, CA 93405Luis Obispo, CA 93405uis Obispo, CA 93405is Obispo, CA 93405s Obispo, CA 93405 Obispo, CA 93405Obispo, CA 93405bispo, CA 93405ispo, CA 93405spo, CA 93405po, CA 93405o, CA 93405, CA 93405 CA 93405CA 93405A 93405 93405 93405934053405405055 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6x6 POST + 2x STUD (5)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Sheathing Material 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SHARED SHEAR WALL POST w/ GREATER HOLDOWN 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan W 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 24" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 14 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 510 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 16" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE9 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2'-9"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan (1) TRIMMER w/ (2) KING STUD (4)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Concrete Anchorage 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan (4) EQUAL DISTANCES 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 869 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4x4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-13 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan POST CENTERED POST ABOVE 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 6" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 15 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDU2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan G 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 34'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6x6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SCALE: 1/4" = 1'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Foundation Plan 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Capacity 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 9Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 19Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan FOUNDATION PLAN NOTES :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates minimum shearwall length 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STRAP AROUND OPENING IN SHEAR WALL ABOVE PER DETAIL 8/S1.38/S1.3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 16 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SINGLE 2x STUD 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 0Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan C 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan NEW 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear clip 'A35'01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-13 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 17 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 1. All shear wall sheathing shall be A.P.A. rated plywood sheathing, Structural 1, exposure 1. 2. Field nailing shall be 10d's @ 12" o.c. unless noted otherwise. 3. All panel edges shall be solid blocked with 2x framing member, EXCEPT use 3x member for nail spacings of 4" o.c. or less. 4. All nails referred shall be Common. 5. Holdowns as shown on the plan are by "Simpson". Refer to Typical Details for end studs and anchor installation guidelines. 6. Provide 1/8" gap between plywood panel edges. 7. Provide 3/8" from center line of nails to edge of stud, plate, and blocking. 8. " " & " " Indicates approximate location of holdowns or straps. Refer to details 5 & 6/S1.1 for concrete anchorage. Refer 5 & 6/S1.1 for concrete anchorage. Refer for concrete anchorage. Refer to detail 4/S1.1 for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. 4/S1.1 for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. 4/S1.3 for strap across floor framing. for strap across floor framing. 9. Framing at adjoining panel edges shall be 3" nominal and nails shall be staggered where nail spacing is 4" o.c. or less. 10. Foundation sill plate anchor bolts shall have steel plate washers under each nut not less than .229"x3"x3" in size. edge of the washer shall be within " from the sheathed side of the shear wall. 12" from the sheathed side of the shear wall. 11. Provide " min. gap between plywood edge and concrete surface at foundation sill plates. 14" min. gap between plywood edge and concrete surface at foundation sill plates. 12. 3x sill required. 13. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR SHEAR WALLS DESIGNATED AS SW2 & SW4. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan C 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 34X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan V 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXTERIOR WOOD STAIR FRAMING SHALL BE PRESSURE-TREATED, TYP. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan MARK 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SEIS. GAP PER ARCH.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan D 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 18 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan MARK 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 22X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan TYP.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXISTING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2'-9"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 9'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Note 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan max. spacing 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan No. C63735 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STEP BOTTOM OF FOOTING AS REQ'D. PER TYP. DET. 11/S1.1 11/S1.111/S1.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 325 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 2" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1,2,3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1. ORIENT POST FOR FULL BEAM WIDTH BEARING 2. U.N.O. ATTACH POST TO SILL PLATE PER DETAIL 3/S1.2. 3/S1.2. 3. POSTS ARE CALLED OUT WHERE THEY ORIGINATE. PROVIDE MATCHING POSTS IN LEVELS ABOVE WHERE BEAM OCCURS AT UPPER LEVELS. 4. SISTER MULTI 2x w/ 16d @ 12" o.c. TYP. 5. SISTER 2x TO 6x6 w/ 16d @ 6" o.c. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 4" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 32" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan W 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear Wall Schedule Notes :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 19 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Nailing 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4x6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 12" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 48" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 12'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 eReview Session for Alt/Add - ADU v.2 FILES:25053 - 619 Grove St Calculations 12.01.25.pdf 619 Grove - Pump Verification Calculation.pdf 619 Grove Street - 1st Building Submittal - 25.1222.pdf CWA Studios - Response Letter - 619 Grove.pdf stormwatercontrolplan.pdf REVIEWER MARKUP DATE/TIME FILE NAME PG # yhassan Remove 02/25/2026 6:14 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 26 yhassan UPDATE 02/25/2026 6:15 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 2 yhassan UPDATE 02/25/2026 6:15 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 3 Page 20 of 20City of San Luis ObispoMarch 18, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) FOR CITY OF SAN LUIS OBISPO PARCEL:001-056-029PERMIT ADDRESS:619 Grove St, A San Luis Obispo, CA 93401 APPLICATION DATE:01/07/2026 EXPIRATION DATE: SQUARE FEET: 920.00 VALUATION:$168,000.00 DESCRIPTION:THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. TO CONSIST OF A 4-BEDROOM, 2-BATHROOM ADU. CONTACTS NAME COMPANY ADDRESS Applicant Chris Allen CWA Studios 1668 Sydney Street San Luis Obispo, CA 93401 Owner John Rourke Alt/Add - ADU REVIEW ITEM STATUS REVIEWER Addressing v.1 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Addressing Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #1 Address assigned to new ADU is 619 A Grove Street. Please update all plan sheets to reflect the newly assigned address. Addressing v.2 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Ready for Action General - Addressing Correction: Administration - Vanessa Nichols (2/20/26) - Resolved Comments: #1 Address assigned to new ADU is 619 A Grove Street. Please update all plan sheets to reflect the newly assigned address. Arborist v.1 Walter Gault email: wgault@slocity.org Needs Resubmit General - Arborist Arborist v.2 Walter Gault email: wgault@slocity.org Needs Resubmit General - Arborist Correction: Urban Forestry - Walter Gault (2/24/26) - Not Resolved Comments: Per Uniform Design Criteria 1010 3.1.23 Street Trees, a minimum of one street tree shall be installed per 35 feet of street frontage for any commercial or residential building permit addition or new dwelling unit, unless City Arborist determines that the site cannot accommodate a new tree. Street trees may be grouped if necessary to avoid conflict with other improvements. Please select a street tree from the City Approved Tree List (Zone 1 tree species), and if in a Fire Hazard Severity Zone, the City of SLO Zone 1 Defensible Space Tree List. Street trees may be planted in front yards to satisfy the requirement. Corrective Action: Please provide a landscaping plan that satisfies the Uniform Design Criteria 1010 3.1.23 Street Trees requirement. Plan shall include tree species selected from Engineering Standard (8010) and Zone 1 category, tree size, location, City Engineering Standards for Tree Planting (8210, 8220, 8250) and an irrigation detail (8670 Tree Bubbler or 8660 Drip Irrigation). Correction: Urban Forestry - Walter Gault (2/24/26) - Not Resolved Comments: Walter Gault, City Arborist, 805-781-7578, wgault@slocity.org Correction: Urban Forestry - Walter Gault (2/24/26) - Not Resolved Comments: If a tree protection and monitoring plan is necessary or a tree removal application and compensatory replanting plan is required, please provide a project arborist to oversee all arboriculture activities. Corrective Action: Please provide a tree protection plan on demo, grading and building permit plan submittals that satisfies Specification 77-1.03A(2) and identifies the location, type, trunk and canopy diameter of all trees onsite (and adjacent offsite) and explains the likelihood of tree retention (based on impact to the critical root zone of trees on- and offsite). An Arborist Report providing further information may be required. Building (True North) v.1 Angelica Tellez email: atellez@slocity.org Needs Resubmit Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E.If you have any questions regarding the comments below, please contact Yazeed Hassan - via email yazeedh@tncservices.com or telephone (562) 733-8030. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A1.Sheet T1.0: Revise occupancy to be R-3 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A2.Sheet T1.0: Revise sheet S3.3 on the index to be S3.2 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A3.Sheet A2.1: Revise door 3 for the bedroom and the bathroom on the first floor to have a width of 3’ to provide 32” clear width for per Aging-in-place requirements. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A4.Sheet A2.1: Detail A/A2.1 referenced on plans does not appear to be provided. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A5.Sheet A5.2: fire rated wall details are not coordinated; sections show gypsum board on the exterior side and fire rated wall details show stucco on the exterior side of the wall. Please provide an approved fire-rated construction detail with basis of approval (i.e., UL design, G.A. file #) for the rated wall and cross reference onto the plans. CRC Table R302.1(1). Page 1 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A6.Sheet A3.2: Provide construction details for the exterior stairs in accordance with CRC 311. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A7.Sheet A4.1: Note 4 refers to detail A and B that appear to be missing. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A8.Sheet MEP1: Provide carbon monoxide alarm in the area leading to bedroom 202. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: M1.Sheet MEP1: Show the location of the bathroom and kitchen exhaust duct termination. Air ducts shall exhaust 3’-0” from property line and 3’-0” from openings into the building. CMC 504.5. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E1.Sheet MEP1: Specify exterior receptacle outlets to be provided with waterproofing cover. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E2.Sheet MEP1: Show the location and size of electrical panel. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: P1.Sheet MEP1: Show the size and location of sewer lateral. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: G1.Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: T1.Sheet T1.0: List all HERS inspection features and special features required. Please coordinate with the Energy Report. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: T2.Sheet A4.1: In the cross section of the building identify the insulation with the respective R-values at the walls, attic/ceiling, floors, and etc. per the Title-24 Certificate of Compliance Form. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S1.Sheet A1.3: Provide calculations and details. Guards and handrails shall be designed to resist a load of 200 psf applied in any direction at the top and to transfer this load through the support structure. CRC R301.5 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S2.Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S3.Sheet S2.1: Detail 1/S3.1 is referenced for continuous footing along gridline 19Y which does not appear to be accurate. Civil and elevation sheets show ADU to be built on sloped land. Please provide accurate details and calculations. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S4.Sheet S2.2: The ridge board shall have bigger thickness than the rafters connected to it. Revise rafters to be 2x10 or ridge board to be 2x14. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S5.Sheet S2.2: Provide framing and foundation details for exterior stairs. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S6.Sheet S2.1: Specify the header size above each exterior opening. Building (True North) v.2 Angelica Tellez email: atellez@slocity.org Needs Resubmit Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E.If you have any questions regarding the comments below, please contact Yazeed Hassan - via email yazeedh@tncservices.com or telephone (562) 733-8030. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A1.Sheet T1.0: Revise occupancy to be R-3 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A2.Sheet T1.0: Revise sheet S3.3 on the index to be S3.2 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A3.Sheet A2.1: Revise door 3 for the bedroom and the bathroom on the first floor to have a width of 3’ to provide 32” clear width for per Aging-in-place requirements. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A4.Sheet A2.1: Detail A/A2.1 referenced on plans does not appear to be provided. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A5.Sheet A5.2: fire rated wall details are not coordinated; sections show gypsum board on the exterior side and fire rated wall details show stucco on the exterior side of the wall. Please provide an approved fire-rated construction detail with basis of approval (i.e., UL design, G.A. file #) for the rated wall and cross reference onto the plans. CRC Table R302.1(1). Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A6.Sheet A3.2: Provide construction details for the exterior stairs in accordance with CRC 311. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A7.Sheet A4.1: Note 4 refers to detail A and B that appear to be missing. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: A8.Sheet MEP1: Provide carbon monoxide alarm in the area leading to bedroom 202. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: M1.Sheet MEP1: Show the location of the bathroom and kitchen exhaust duct termination. Air ducts shall exhaust 3’-0” from property line and 3’-0” from openings into the building. CMC 504.5. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: E1.Sheet MEP1: Specify exterior receptacle outlets to be provided with waterproofing cover. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Page 2 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Comments: E2.Sheet MEP1: Show the location and size of electrical panel. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: P1.Sheet MEP1: Show the size and location of sewer lateral. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Not Resolved Comments: G1.Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Corrective Action: PC2: Comment remains. Provide updated checklist. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: T1.Sheet T1.0: List all HERS inspection features and special features required. Please coordinate with the Energy Report. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: T2.Sheet A4.1: In the cross section of the building identify the insulation with the respective R-values at the walls, attic/ceiling, floors, and etc. per the Title-24 Certificate of Compliance Form. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S1.Sheet A1.3: Provide calculations and details. Guards and handrails shall be designed to resist a load of 200 psf applied in any direction at the top and to transfer this load through the support structure. CRC R301.5 Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Not Resolved Comments: S2.Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Corrective Action: PC2: No geotechnical report is provided. Remove the slab on grade note on sheet S2.1 referring to a geotechnical report. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S3.Sheet S2.1: Detail 1/S3.1 is referenced for continuous footing along gridline 19Y which does not appear to be accurate. Civil and elevation sheets show ADU to be built on sloped land. Please provide accurate details and calculations. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S4.Sheet S2.2: The ridge board shall have bigger thickness than the rafters connected to it. Revise rafters to be 2x10 or ridge board to be 2x14. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S5.Sheet S2.2: Provide framing and foundation details for exterior stairs. Correction: Building Code Compliance - Angelica Tellez (2/20/26) - Resolved Comments: S6.Sheet S2.1: Specify the header size above each exterior opening. Code Enforcement General v.1 Steve Sheats email: ssheats@slocity.org Needs Resubmit Code Enforcement General Code Enforcement General v.2 Steve Sheats email: ssheats@slocity.org Ready for Action Code Enforcement General Fees v.1 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Fees Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #3 Final fees pending response to comments and other department reviews. Fees v.2 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Fees Correction: Administration - Vanessa Nichols (2/20/26) - Not Resolved Comments: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Correction: Administration - Vanessa Nichols (2/20/26) - Not Resolved Comments: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. PARTIAL COMMENT REMAINS: Plumbing calc needs to reflect the upgrade of water meter and service. Sheet Reference Note #9. Sheet S1.1, needs to be update to reflect the water meter being upgraded. Correction: Administration - Vanessa Nichols (2/20/26) - Not Resolved Comments: #3 Final fees pending response to comments and other department reviews. Planning v.1 Ethan Estrada email: ejestrad@slocity.org Needs Resubmit General - Planning Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Resolved Comments: Ethan Estrada (Asst. Planner) | ejestrad@slocity.org | (805) 781-7576 Corrective Action: Contact Info Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Corrective Action: Process Tracking Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Trees appear to possibly be impacted by your project proposal and will require review by the City Arborist. An arborist report may be required. Page 3 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Corrective Action: Trees Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Provide expanded calculations/confirm the existing lot coverage for this property on the title sheet. Corrective Action: Lot Coverage Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Title sheet states one parking space is provided in the driveway. On the site plan, note the location and dimensions of this parking space - keep in mind that parking may not be located in the front yard setback. Corrective Action: Parking Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: The MEP plan depicts a condenser on the north side of the proposed addition, but the site plan and elevations do not depict this mechanical equipment. Ensure this equipment is depicted consistently throughout the plan set - note the distance between the condenser and the north property line on the site plan. Corrective Action: Proposed Condenser Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.080, the height of structures on properties with an average cross-parcel slope less than 16% shall be measured from the average natural grade of the portion of the parcel that the proposed structure is to be built on. Adjust the height measurements provided on the elevations so that they are measured from average natural grade. Corrective Action: Avg. Natural Grade Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: On the elevations, note the direction from which the elevations are being viewed from. Corrective Action: Elevation Labels Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: MEP plan indicates that there will be exterior lighting. Ensure that such lighting is also depicted in the elevations. Corrective Action: Elevations & Lighting Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Exterior Light Fixtures Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Lighting Levels Planning v.2 Ethan Estrada email: ejestrad@slocity.org Needs Resubmit General - Planning Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Resolved Comments: Ethan Estrada (Asst. Planner) | ejestrad@slocity.org | (805) 781-7576 Corrective Action: Contact Info Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Not Resolved Comments: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Corrective Action: Process Tracking Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Trees appear to possibly be impacted by your project proposal and will require review by the City Arborist. An arborist report may be required. Corrective Action: Trees Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Provide expanded calculations/confirm the existing lot coverage for this property on the title sheet. Corrective Action: Lot Coverage Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Title sheet states one parking space is provided in the driveway. On the site plan, note the location and dimensions of this parking space - keep in mind that parking may not be located in the front yard setback. Corrective Action: Parking Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: The MEP plan depicts a condenser on the north side of the proposed addition, but the site plan and elevations do not depict this mechanical equipment. Ensure this equipment is depicted consistently throughout the plan set - note the distance between the condenser and the north property line on the site plan. Corrective Action: Proposed Condenser Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: Per SLOMC 17.70.080, the height of structures on properties with an average cross-parcel slope less than 16% shall be measured from the average natural grade of the portion of the parcel that the proposed structure is to be built on. Adjust the height measurements provided on the elevations so that they are measured from average natural grade. Corrective Action: Avg. Natural Grade Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Comments: On the elevations, note the direction from which the elevations are being viewed from. Corrective Action: Elevation Labels Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Resolved Page 4 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Comments: MEP plan indicates that there will be exterior lighting. Ensure that such lighting is also depicted in the elevations. Corrective Action: Elevations & Lighting Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Exterior Light Fixtures Correction: Planning and Zoning Compliance - Ethan Estrada (2/20/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Lighting Levels Correction: Planning and Zoning Compliance - Ethan Estrada (3/3/26) - Not Resolved Comments: Upon further review, it's been noted that the site plan shows what appears to be another condenser on the south side of the proposed ADU that encroaches into the existing easement. This equipment is not shown on any other sheet in the plan set. Is this condenser supposed to be a part of this project? If it is, it will need to be relocated out of the existing easement. Corrective Action: Proposed Mechanical Equipment in Easement Private Sewer Lateral v.1 Ready for Action Private Sewer Lateral Inspection requirements (per Muni Code section 13.08.395) Private Sewer Lateral v.2 Ryan Beech email: rbeech@slocity.org Ready for Action Private Sewer Lateral Inspection requirements (per Muni Code section 13.08.395) Public Works Permit Review v.1 Emma LaPlante email: elaplant@slocity.org Needs Resubmit General - Public Works Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 0.Emma Laplante – elaplant@slocity.org or 805-781-7199 Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 1.Include the following note under Standard Public Works Notes a.All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 2.These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 3.Update Standard Public Works Notes to reference the December 2025 City standard Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 4.A System certification is required from the engineer of record prior to final inspection approvals. The engineer shall certify that the drainage and stormwater system components have been inspected and are in general conformance with the drainage report, system design, and the approved plans, including all final elevations, component sizing, detention basins, parking lot detention curb elevations, drainage piping, inlets, weir elevations, and orifices Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 5.No project type is checked on the Stormwater Control Plan for Post Construction Requirements, please revise. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 6.Clarify the Proposed drainage strategy a.If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. c.Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain d.Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 7.Revise Plans as follows: a.For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. b.Show existing utility on all sheets with a line, not just a callout. c.Clearly show the drive approach and driveway on the plans. d.There are abbreviations used that are not included in the legend e.A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed f.Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g.The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. h.Show the material of the existing utility. See the attached Utility grid maps for reference. i.Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 8.The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Page 5 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Public Works Permit Review v.2 Emma LaPlante email: elaplant@slocity.org Needs Resubmit General - Public Works Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 0.Emma Laplante – elaplant@slocity.org or 805-781-7199 Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 1.Include the following note under Standard Public Works Notes a.All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 2.These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 3.Update Standard Public Works Notes to reference the December 2025 City standard Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 4.A System certification is required from the engineer of record prior to final inspection approvals. The engineer shall certify that the drainage and stormwater system components have been inspected and are in general conformance with the drainage report, system design, and the approved plans, including all final elevations, component sizing, detention basins, parking lot detention curb elevations, drainage piping, inlets, weir elevations, and orifices Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Resolved Comments: 5.No project type is checked on the Stormwater Control Plan for Post Construction Requirements, please revise. Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 6.Clarify the Proposed drainage strategy a.If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. Resolved b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. Comment Remain: Water shall not be pumped into the street. Invert/location needs to be revised to allow for gravity flow into the street. c.Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain. Resolved d.Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Resolved Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 7.Revise Plans as follows: a.For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. Resolved b.Show existing utility on all sheets with a line, not just a callout. c.Clearly show the drive approach and driveway on the plans. Comment Remains: Through additional research it seems like the drive approach is being converted to curb under BLDG-1030-2023/ENCR-0189-2026. In addition is also appears that the Majority of the driveway will be replace with concrete under the same permit. Please revise the plans to reflect the changes under the above listed permit. d.There are abbreviations used that are not included in the legend. Resolved e.A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed. Comment remains: TOPO shows brick pavers where the ADU is going but there are no call outs to remove them. Please clarify f.Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g.The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. Comment remain: plans need to reflect the improvement outline in BLDG-1030-2023/ENCR-0189-2026 h.Show the material of the existing utility. See the attached Utility grid maps for reference. Resolved i.Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach. Resolved Correction: Engineering Standards Compliance - Emma LaPlante (2/20/26) - Not Resolved Comments: 8.The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Resolved: See utility comments Correction: Engineering Standards Compliance - Emma LaPlante (2/27/26) - Not Resolved Comments: 9.Additional Plan Comments a.There is a discrepancy in the property line between the approved build plans for Parcel 1 (back parcel) and current plans for Parcel 2. Provide verification from the survey on which property line location is correct. Recycling v.1 Rachelle Paris email: rparis@slocity.org Ready for Action General - Recycling Utilities Project Manager (Building) v.2 Nico Gurney email: ngurney@slocity.org Needs Resubmit General - Utilities Correction: Utilities - Nico Gurney (2/27/26) - Not Resolved Comments: Sheet AS1.0: Does sewer lateral from parcel one also feed the proposed sewer pump? Wastewater Offset v.2 Nico Gurney email: ngurney@slocity.org Needs Resubmit Wastewater Offset Page 6 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) eReview Session for Alt/Add - ADU v.1 FILES:25053 - 619 Grove St Calculations 12.01.25.pdf 619 Grove Street - 1st Building Submittal - 25.1222.pdf Construction and Demolition Recycling and Waste Pl.pdf GroveT24OFFICIL.pdf Soils Waiver Application.pdf stormwatercontrolplan.pdf waterpollutioncontrolplan.pdf REVIEWER MARKUP DATE/TIME FILE NAME PG # yhassan R-3 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan ADD HERS SPECIAL FEATURES 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan GROVE ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan MONTEREY ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan MILL ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan GRAND AVE 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan HILLCREST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan 101 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan S3.2 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan FILL OUT 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 2 yhassan FILL OUT 01/16/2026 7:10 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 3 yhassan SHOW CLEARANCES 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-10 3/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 Page 7 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan A122.Newly constructed dwelling units including detached ADUs are required to comply with Aging-In-Place requirements in accordance with CRC R327. Address the following comments: a)At least one bathroom and one bedroom shall be provided with a net clear opening of not less than 32 inches. Per CRC.R327.1.3 b)At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least one bathroom on the floor above shall comply with this section. i)Specify the reinforcement to be solid lumber and not less than 2X8. ii)The reinforcement shall be located between 32” and 39 ¼” above the finished floor. iii)Specify the water closet reinforcement to be installed on both side walls of the fixture, or one side wall and the back wall. (1)Where the water closet is not located adjacent to the side wall, grab bar reinforcement for a ground-mounted installation is acceptable. iv)Specify the shower reinforcement shall be continuous where wall framing is provided. v)Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6” above the bathtub rim. c)Note on plans: Electrical receptacle outlets, switches and controls intended to be used by occupants shall be located no more than 48” measured from the top of the outlet box and not less than 15” measured from the bottom of the outlet box above the finish floor. d)Specify doorbell controls to not exceed 48” above exterior floor, measured from the top of the doorbell button assembly. 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan Provide guardrail details and calculations 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan SHOW CLEARANCES 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 2'-6"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-10 3/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan SHOW LOCATION AND SIZE OF ATTIC 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-4 1/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 2'-6"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-4 1/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan R-VALUES?01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 12 yhassan PROVIDE STC MINIMUM 50 RATING FOR FIRE SEPARATION 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan L = 7'-2 1/2"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan PROVIDE STC MINIMUM 50 RATING FOR FIRE SEPARATION 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan L = 7'-2 1/2"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan SHOW DUCT TERMINATION 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 Page 8 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan MS 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 yhassan VACANCY / DIMMING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 0X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STEEL SHOULD BE HELD IN PLACE BY STIRRUPS AT APPROPRIATE SPACING TO ENSURE PROPER POSITIONING OF THE STEEL (SEE WRI DESIGN OF SLAB-ON-GROUND FOUNDATIONS AND ACI 318, SECTION 26.6.6 - PLACING REINFORCEMENT). 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Tel. (805) 548-8600 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan U.N.O. CONCRETE SLAB ON GRADE TO BE PER DETAIL 6/S3.1. REFER 6/S3.1. REFER . REFER TO PROJECT GEOTECHNICAL REPORT FOR ADDITIONAL REQUIREMENTS 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan J 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Size 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan TYP.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 22'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates shearwall type designation per schedule 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan REVISE NOTE AS NO GEOTECHNICAL REPORT WAS PROVIDED. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Fax (805) 548-8601 Fax (805) 548-8601 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 9 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan P 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan REFER TO DETAIL 7/S1.2 7/S1.2 FOR TYPICAL HEADER SIZES U.N.O. ON PLAN 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan UNDERPIN EXISTING FOOTING w/ SLURRY TO BOTTOM OF (N) FOOTING AT THE TIME OF (N) FOOTING CONSTRUCTION. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan OUTLINE OF EXISTING BUILDING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Wood Posts 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Edge 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXP. 9/2026 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan FOUNDATION KEYED NOTES :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan UNDERPIN EXISTING FOOTING w/ SLURRY 2'-0" MIN. BELOW BOTTOM OF (E) FOOTING PRIOR TO (N) FOOTING CONSTRUCTION. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan DBL. STUD OR DBL. KING STUD (4)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Arrow indicates anticipated side of wall to shear 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-11 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan U 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan G 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear Wall Schedule (SW)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates strap or holdown each end of shear wall 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan BALLOON FRAME WALLS TO ROOF AT STAIR WELL 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shaded region indicates shear wall 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 10 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 555 Chorro St., Ste. A1 San Luis Obispo, CA 9340555 Chorro St., Ste. A1 San Luis Obispo, CA 934055 Chorro St., Ste. A1 San Luis Obispo, CA 93405 Chorro St., Ste. A1 San Luis Obispo, CA 93405Chorro St., Ste. A1 San Luis Obispo, CA 93405horro St., Ste. A1 San Luis Obispo, CA 93405orro St., Ste. A1 San Luis Obispo, CA 93405rro St., Ste. A1 San Luis Obispo, CA 93405ro St., Ste. A1 San Luis Obispo, CA 93405o St., Ste. A1 San Luis Obispo, CA 93405 St., Ste. A1 San Luis Obispo, CA 93405St., Ste. A1 San Luis Obispo, CA 93405t., Ste. A1 San Luis Obispo, CA 93405., Ste. A1 San Luis Obispo, CA 93405, Ste. A1 San Luis Obispo, CA 93405 Ste. A1 San Luis Obispo, CA 93405Ste. A1 San Luis Obispo, CA 93405te. A1 San Luis Obispo, CA 93405e. A1 San Luis Obispo, CA 93405. A1 San Luis Obispo, CA 93405 A1 San Luis Obispo, CA 93405A1 San Luis Obispo, CA 934051 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405San Luis Obispo, CA 93405an Luis Obispo, CA 93405n Luis Obispo, CA 93405 Luis Obispo, CA 93405Luis Obispo, CA 93405uis Obispo, CA 93405is Obispo, CA 93405s Obispo, CA 93405 Obispo, CA 93405Obispo, CA 93405bispo, CA 93405ispo, CA 93405spo, CA 93405po, CA 93405o, CA 93405, CA 93405 CA 93405CA 93405A 93405 93405 93405934053405405055 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6x6 POST + 2x STUD (5)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Sheathing Material 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SHARED SHEAR WALL POST w/ GREATER HOLDOWN 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan W 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 24" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 11 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 510 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 16" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE9 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2'-9"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan (1) TRIMMER w/ (2) KING STUD (4)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Concrete Anchorage 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan (4) EQUAL DISTANCES 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 869 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4x4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-13 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan POST CENTERED POST ABOVE 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 6" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 12 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDU2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan G 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 34'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6x6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SCALE: 1/4" = 1'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Foundation Plan 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Capacity 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 9Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 19Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan FOUNDATION PLAN NOTES :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates minimum shearwall length 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STRAP AROUND OPENING IN SHEAR WALL ABOVE PER DETAIL 8/S1.38/S1.3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 13 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SINGLE 2x STUD 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 0Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan C 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan NEW 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear clip 'A35'01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-13 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 14 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 1. All shear wall sheathing shall be A.P.A. rated plywood sheathing, Structural 1, exposure 1. 2. Field nailing shall be 10d's @ 12" o.c. unless noted otherwise. 3. All panel edges shall be solid blocked with 2x framing member, EXCEPT use 3x member for nail spacings of 4" o.c. or less. 4. All nails referred shall be Common. 5. Holdowns as shown on the plan are by "Simpson". Refer to Typical Details for end studs and anchor installation guidelines. 6. Provide 1/8" gap between plywood panel edges. 7. Provide 3/8" from center line of nails to edge of stud, plate, and blocking. 8. " " & " " Indicates approximate location of holdowns or straps. Refer to details 5 & 6/S1.1 for concrete anchorage. Refer 5 & 6/S1.1 for concrete anchorage. Refer for concrete anchorage. Refer to detail 4/S1.1 for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. 4/S1.1 for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. 4/S1.3 for strap across floor framing. for strap across floor framing. 9. Framing at adjoining panel edges shall be 3" nominal and nails shall be staggered where nail spacing is 4" o.c. or less. 10. Foundation sill plate anchor bolts shall have steel plate washers under each nut not less than .229"x3"x3" in size. edge of the washer shall be within " from the sheathed side of the shear wall. 12" from the sheathed side of the shear wall. 11. Provide " min. gap between plywood edge and concrete surface at foundation sill plates. 14" min. gap between plywood edge and concrete surface at foundation sill plates. 12. 3x sill required. 13. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR SHEAR WALLS DESIGNATED AS SW2 & SW4. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan C 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 34X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan V 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXTERIOR WOOD STAIR FRAMING SHALL BE PRESSURE-TREATED, TYP. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan MARK 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SEIS. GAP PER ARCH.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan D 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 15 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan MARK 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 22X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan TYP.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXISTING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2'-9"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 9'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Note 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan max. spacing 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan No. C63735 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STEP BOTTOM OF FOOTING AS REQ'D. PER TYP. DET. 11/S1.1 11/S1.111/S1.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 325 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 2" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1,2,3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1. ORIENT POST FOR FULL BEAM WIDTH BEARING 2. U.N.O. ATTACH POST TO SILL PLATE PER DETAIL 3/S1.2. 3/S1.2. 3. POSTS ARE CALLED OUT WHERE THEY ORIGINATE. PROVIDE MATCHING POSTS IN LEVELS ABOVE WHERE BEAM OCCURS AT UPPER LEVELS. 4. SISTER MULTI 2x w/ 16d @ 12" o.c. TYP. 5. SISTER 2x TO 6x6 w/ 16d @ 6" o.c. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 4" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 32" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan W 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear Wall Schedule Notes :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 16 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Nailing 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4x6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 12" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 48" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 12'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 eReview Session for Alt/Add - ADU v.2 FILES:25053 - 619 Grove St Calculations 12.01.25.pdf 619 Grove - Pump Verification Calculation.pdf 619 Grove Street - 1st Building Submittal - 25.1222.pdf CWA Studios - Response Letter - 619 Grove.pdf stormwatercontrolplan.pdf REVIEWER MARKUP DATE/TIME FILE NAME PG # yhassan Remove 02/25/2026 6:14 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 26 yhassan UPDATE 02/25/2026 6:15 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 2 yhassan UPDATE 02/25/2026 6:15 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 3 Page 17 of 17City of San Luis ObispoMarch 03, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) FOR CITY OF SAN LUIS OBISPO PARCEL:001-056-052PERMIT ADDRESS:619 Grove St San Luis Obispo, CA 93401 APPLICATION DATE:01/07/2026 EXPIRATION DATE: SQUARE FEET: 920.00 VALUATION:$168,000.00 DESCRIPTION:THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. TO CONSIST OF A 4-BEDROOM, 2-BATHROOM ADU. CONTACTS NAME COMPANY ADDRESS Applicant Chris Allen CWA Studios 1668 Sydney Street San Luis Obispo, CA 93401 Owner John Rourke Alt/Add - ADU REVIEW ITEM STATUS REVIEWER Addressing v.1 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Addressing Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #1 Address assigned to new ADU is 619 A Grove Street. Please update all plan sheets to reflect the newly assigned address. Arborist v.1 Walter Gault email: wgault@slocity.org Needs Resubmit General - Arborist Building (True North) v.1 Angelica Tellez email: atellez@slocity.org Needs Resubmit Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E.If you have any questions regarding the comments below, please contact Yazeed Hassan - via email yazeedh@tncservices.com or telephone (562) 733-8030. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A1.Sheet T1.0: Revise occupancy to be R-3 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A2.Sheet T1.0: Revise sheet S3.3 on the index to be S3.2 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A3.Sheet A2.1: Revise door 3 for the bedroom and the bathroom on the first floor to have a width of 3’ to provide 32” clear width for per Aging-in-place requirements. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A4.Sheet A2.1: Detail A/A2.1 referenced on plans does not appear to be provided. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A5.Sheet A5.2: fire rated wall details are not coordinated; sections show gypsum board on the exterior side and fire rated wall details show stucco on the exterior side of the wall. Please provide an approved fire-rated construction detail with basis of approval (i.e., UL design, G.A. file #) for the rated wall and cross reference onto the plans. CRC Table R302.1(1). Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A6.Sheet A3.2: Provide construction details for the exterior stairs in accordance with CRC 311. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A7.Sheet A4.1: Note 4 refers to detail A and B that appear to be missing. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: A8.Sheet MEP1: Provide carbon monoxide alarm in the area leading to bedroom 202. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: M1.Sheet MEP1: Show the location of the bathroom and kitchen exhaust duct termination. Air ducts shall exhaust 3’-0” from property line and 3’-0” from openings into the building. CMC 504.5. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E1.Sheet MEP1: Specify exterior receptacle outlets to be provided with waterproofing cover. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: E2.Sheet MEP1: Show the location and size of electrical panel. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: P1.Sheet MEP1: Show the size and location of sewer lateral. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: G1.Sheet T1.1: Provide the most recent calgreen checklist version (July2024 supplement) Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: T1.Sheet T1.0: List all HERS inspection features and special features required. Please coordinate with the Energy Report. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: T2.Sheet A4.1: In the cross section of the building identify the insulation with the respective R-values at the walls, attic/ceiling, floors, and etc. per the Title-24 Certificate of Compliance Form. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S1.Sheet A1.3: Provide calculations and details. Guards and handrails shall be designed to resist a load of 200 psf applied in any Page 1 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) direction at the top and to transfer this load through the support structure. CRC R301.5 Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S2.Sheet S2.1: Foundation plan refers to a geotechnical report, please provide report for review. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S3.Sheet S2.1: Detail 1/S3.1 is referenced for continuous footing along gridline 19Y which does not appear to be accurate. Civil and elevation sheets show ADU to be built on sloped land. Please provide accurate details and calculations. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S4.Sheet S2.2: The ridge board shall have bigger thickness than the rafters connected to it. Revise rafters to be 2x10 or ridge board to be 2x14. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S5.Sheet S2.2: Provide framing and foundation details for exterior stairs. Correction: Building Code Compliance - Angelica Tellez (1/26/26) - Not Resolved Comments: S6.Sheet S2.1: Specify the header size above each exterior opening. Code Enforcement General v.1 Steve Sheats email: ssheats@slocity.org Needs Resubmit Code Enforcement General Fees v.1 Vanessa Nichols Ph: 8057817588 email: vnichols@slocity.org Needs Resubmit General - Fees Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #1 CODE-000350-2024 remains unresolved. Plans shall be approved to resolve that code case prior to additional permits being approved. Please submit an application to resolve. Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #2 Please provide a plumbing calculation to verify that the existing water meter and water service will be sufficient to service both the existing residence and the new ADU. Correction: Administration - Vanessa Nichols (1/27/26) - Not Resolved Comments: #3 Final fees pending response to comments and other department reviews. Planning v.1 Ethan Estrada email: ejestrad@slocity.org Needs Resubmit General - Planning Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Resolved Comments: Ethan Estrada (Asst. Planner) | ejestrad@slocity.org | (805) 781-7576 Corrective Action: Contact Info Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: For process tracking purposes, this correction will remain until all other corrections provided for this permit application have been resolved. Corrective Action: Process Tracking Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Trees appear to possibly be impacted by your project proposal and will require review by the City Arborist. An arborist report may be required. Corrective Action: Trees Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Provide expanded calculations/confirm the existing lot coverage for this property on the title sheet. Corrective Action: Lot Coverage Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Title sheet states one parking space is provided in the driveway. On the site plan, note the location and dimensions of this parking space - keep in mind that parking may not be located in the front yard setback. Corrective Action: Parking Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: The MEP plan depicts a condenser on the north side of the proposed addition, but the site plan and elevations do not depict this mechanical equipment. Ensure this equipment is depicted consistently throughout the plan set - note the distance between the condenser and the north property line on the site plan. Corrective Action: Proposed Condenser Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.080, the height of structures on properties with an average cross-parcel slope less than 16% shall be measured from the average natural grade of the portion of the parcel that the proposed structure is to be built on. Adjust the height measurements provided on the elevations so that they are measured from average natural grade. Corrective Action: Avg. Natural Grade Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: On the elevations, note the direction from which the elevations are being viewed from. Corrective Action: Elevation Labels Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: MEP plan indicates that there will be exterior lighting. Ensure that such lighting is also depicted in the elevations. Corrective Action: Elevations & Lighting Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide manufacturer’s catalog cuts and drawings of all proposed exterior lighting to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Exterior Light Fixtures Page 2 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) Correction: Planning and Zoning Compliance - Ethan Estrada (1/28/26) - Not Resolved Comments: Per SLOMC 17.70.100(B), provide a 10’ by 10’ grid of both the initial and maintained lighting levels of all proposed exterior lighting onsite, including impact on adjacent properties, to confirm compliance with SLOMC 17.70.100 as required in SLOMC 17.69.040(E). Corrective Action: Lighting Levels Private Sewer Lateral v.1 Ready for Action Private Sewer Lateral Inspection requirements (per Muni Code section 13.08.395) Public Works Permit Review v.1 Emma LaPlante email: elaplant@slocity.org Needs Resubmit General - Public Works Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 0.Emma Laplante – elaplant@slocity.org or 805-781-7199 Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 1.Include the following note under Standard Public Works Notes a.All surface and subsurface drainage systems designed at less than 2% shall have final gradients certified by a licensed surveyor or engineer prior to final inspection approvals. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 2.These plans are considered incomplete and additional comments may apply when all minimum plan information and/or supporting documentation is provided through the plan review process. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 3.Update Standard Public Works Notes to reference the December 2025 City standard Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 4.A System certification is required from the engineer of record prior to final inspection approvals. The engineer shall certify that the drainage and stormwater system components have been inspected and are in general conformance with the drainage report, system design, and the approved plans, including all final elevations, component sizing, detention basins, parking lot detention curb elevations, drainage piping, inlets, weir elevations, and orifices Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 5.No project type is checked on the Stormwater Control Plan for Post Construction Requirements, please revise. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 6.Clarify the Proposed drainage strategy a.If physical obstructions or lot lines prohibit 10 feet of horizontal distance, 5% slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2% along the flowline. b. Revise the invert elevations to provide a minimum 2% gradient if practical. As an alternative, the gradients may be reduced to not less than 1% when verified by a licensed surveyor or engineer. This is including the outlet pipe to the street. c.Show limits of sidewalk restoration from score mark to score mark for this sidewalk underdrain d.Provide details and calculations for hydrologic assessment and sump pump capacity. The proposed engineered drainage system will require the engineer of record to certify the system is built in conformance with the system design and approved plans prior to final inspection. Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 7.Revise Plans as follows: a.For Grove Street, note or dimension the 70’ right-of-way width on the site plan. Show the 35’ dimension of the centerline to property line, 23’ centerline to face of curb, and 12’ from face of curb to property line dimensions for reference. b.Show existing utility on all sheets with a line, not just a callout. c.Clearly show the drive approach and driveway on the plans. d.There are abbreviations used that are not included in the legend e.A Complete site demolition plan for reference. Show all existing and proposed site improvements, plantings, and utilities to remain and to be removed f.Based on Google Earth there is a utility box located on the south side of the drive approach. Please verify g.The plans call for the driveway to remain, but site plan sheet shows installation of 2” Schedule 40 PVC Drain pipe along the drive. Please clarify the approach for installation. h.Show the material of the existing utility. See the attached Utility grid maps for reference. i.Confirm Parcel 1 water meter is shown in the correct location, The approved building plans for parcel 1 shows it closer to the drive approach Correction: Engineering Standards Compliance - Emma LaPlante (1/27/26) - Not Resolved Comments: 8.The Utilities department will be added to the next round of review you can expect possible comments from them in regard to the new ADU Lateral connecting to Parcel 1 sewer lateral. Recycling v.1 Rachelle Paris email: rparis@slocity.org Ready for Action General - Recycling Page 3 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) eReview Session for Alt/Add - ADU v.1 FILES:25053 - 619 Grove St Calculations 12.01.25.pdf 619 Grove Street - 1st Building Submittal - 25.1222.pdf Construction and Demolition Recycling and Waste Pl.pdf GroveT24OFFICIL.pdf Soils Waiver Application.pdf stormwatercontrolplan.pdf waterpollutioncontrolplan.pdf REVIEWER MARKUP DATE/TIME FILE NAME PG # yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan REFER TO DETAIL 7/S1.2 7/S1.2 FOR TYPICAL HEADER SIZES U.N.O. ON PLAN 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 4" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2'-9"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan MARK 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-13 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear Wall Schedule Notes :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 19Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan FOUNDATION PLAN NOTES :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-13 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Arrow indicates anticipated side of wall to shear 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1-11 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 34X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 101 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan MILL ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan GROVE ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan ADD HERS SPECIAL FEATURES 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan R-3 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan MONTEREY ST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 Page 4 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan GRAND AVE 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan HILLCREST 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan S3.2 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 1 yhassan FILL OUT 01/16/2026 7:09 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 2 yhassan FILL OUT 01/16/2026 7:10 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 3 yhassan 2'-6"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 2'-6"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan A122.Newly constructed dwelling units including detached ADUs are required to comply with Aging-In-Place requirements in accordance with CRC R327. Address the following comments: a)At least one bathroom and one bedroom shall be provided with a net clear opening of not less than 32 inches. Per CRC.R327.1.3 b)At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least one bathroom on the floor above shall comply with this section. i)Specify the reinforcement to be solid lumber and not less than 2X8. ii)The reinforcement shall be located between 32” and 39 ¼” above the finished floor. iii)Specify the water closet reinforcement to be installed on both side walls of the fixture, or one side wall and the back wall. (1)Where the water closet is not located adjacent to the side wall, grab bar reinforcement for a ground-mounted installation is acceptable. iv)Specify the shower reinforcement shall be continuous where wall framing is provided. v)Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6” above the bathtub rim. c)Note on plans: Electrical receptacle outlets, switches and controls intended to be used by occupants shall be located no more than 48” measured from the top of the outlet box and not less than 15” measured from the bottom of the outlet box above the finish floor. d)Specify doorbell controls to not exceed 48” above exterior floor, measured from the top of the doorbell button assembly. 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-4 1/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan SHOW CLEARANCES 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-10 3/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-10 3/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan 1'-4 1/4"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan Provide guardrail details and calculations 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan SHOW CLEARANCES 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 Page 5 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan SHOW LOCATION AND SIZE OF ATTIC 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 9 yhassan R-VALUES?01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 12 yhassan PROVIDE STC MINIMUM 50 RATING FOR FIRE SEPARATION 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan L = 7'-2 1/2"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan PROVIDE STC MINIMUM 50 RATING FOR FIRE SEPARATION 01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan L = 7'-2 1/2"01/16/2026 7:11 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 14 yhassan MS 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 yhassan VACANCY / DIMMING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 yhassan SHOW DUCT TERMINATION 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 16 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SHARED SHEAR WALL POST w/ GREATER HOLDOWN 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Edge 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXP. 9/2026 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan FOUNDATION KEYED NOTES :01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear clip 'A35'01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan U.N.O. CONCRETE SLAB ON GRADE TO BE PER DETAIL 6/S3.1. REFER 6/S3.1. REFER . REFER TO PROJECT GEOTECHNICAL REPORT FOR ADDITIONAL REQUIREMENTS 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates strap or holdown each end of shear wall 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan NEW 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan C 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 6 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 10d @ 6" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 16" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STEP BOTTOM OF FOOTING AS REQ'D. PER TYP. DET. 11/S1.1 11/S1.111/S1.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan DBL. STUD OR DBL. KING STUD (4)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan UNDERPIN EXISTING FOOTING w/ SLURRY 2'-0" MIN. BELOW BOTTOM OF (E) FOOTING PRIOR TO (N) FOOTING CONSTRUCTION. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Concrete Anchorage 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan (4) EQUAL DISTANCES 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 869 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4x4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan OUTLINE OF EXISTING BUILDING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STEEL SHOULD BE HELD IN PLACE BY STIRRUPS AT APPROPRIATE SPACING TO ENSURE PROPER POSITIONING OF THE STEEL (SEE WRI DESIGN OF SLAB-ON-GROUND FOUNDATIONS AND ACI 318, SECTION 26.6.6 - PLACING REINFORCEMENT). 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Tel. (805) 548-8600 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE9 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 7 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 555 Chorro St., Ste. A1 San Luis Obispo, CA 9340555 Chorro St., Ste. A1 San Luis Obispo, CA 934055 Chorro St., Ste. A1 San Luis Obispo, CA 93405 Chorro St., Ste. A1 San Luis Obispo, CA 93405Chorro St., Ste. A1 San Luis Obispo, CA 93405horro St., Ste. A1 San Luis Obispo, CA 93405orro St., Ste. A1 San Luis Obispo, CA 93405rro St., Ste. A1 San Luis Obispo, CA 93405ro St., Ste. A1 San Luis Obispo, CA 93405o St., Ste. A1 San Luis Obispo, CA 93405 St., Ste. A1 San Luis Obispo, CA 93405St., Ste. A1 San Luis Obispo, CA 93405t., Ste. A1 San Luis Obispo, CA 93405., Ste. A1 San Luis Obispo, CA 93405, Ste. A1 San Luis Obispo, CA 93405 Ste. A1 San Luis Obispo, CA 93405Ste. A1 San Luis Obispo, CA 93405te. A1 San Luis Obispo, CA 93405e. A1 San Luis Obispo, CA 93405. A1 San Luis Obispo, CA 93405 A1 San Luis Obispo, CA 93405A1 San Luis Obispo, CA 934051 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405 San Luis Obispo, CA 93405San Luis Obispo, CA 93405an Luis Obispo, CA 93405n Luis Obispo, CA 93405 Luis Obispo, CA 93405Luis Obispo, CA 93405uis Obispo, CA 93405is Obispo, CA 93405s Obispo, CA 93405 Obispo, CA 93405Obispo, CA 93405bispo, CA 93405ispo, CA 93405spo, CA 93405po, CA 93405o, CA 93405, CA 93405 CA 93405CA 93405A 93405 93405 93405934053405405055 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 325 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Size 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan C 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan J 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan W 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 8 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 5/8"%%C A.B. @ 48" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 24" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan No. C63735 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5/8"%%C A.B. @ 32" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan W 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1. All shear wall sheathing shall be A.P.A. rated plywood sheathing, Structural 1, exposure 1. 2. Field nailing shall be 10d's @ 12" o.c. unless noted otherwise. 3. All panel edges shall be solid blocked with 2x framing member, EXCEPT use 3x member for nail spacings of 4" o.c. or less. 4. All nails referred shall be Common. 5. Holdowns as shown on the plan are by "Simpson". Refer to Typical Details for end studs and anchor installation guidelines. 6. Provide 1/8" gap between plywood panel edges. 7. Provide 3/8" from center line of nails to edge of stud, plate, and blocking. 8. " " & " " Indicates approximate location of holdowns or straps. Refer to details 5 & 6/S1.1 for concrete anchorage. Refer 5 & 6/S1.1 for concrete anchorage. Refer for concrete anchorage. Refer to detail 4/S1.1 for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. 4/S1.1 for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. for min. chord requirements for HDUE's. Refer to detail 4/S1.3 for strap across floor framing. 4/S1.3 for strap across floor framing. for strap across floor framing. 9. Framing at adjoining panel edges shall be 3" nominal and nails shall be staggered where nail spacing is 4" o.c. or less. 10. Foundation sill plate anchor bolts shall have steel plate washers under each nut not less than .229"x3"x3" in size. edge of the washer shall be within " from the sheathed side of the shear wall. 12" from the sheathed side of the shear wall. 11. Provide " min. gap between plywood edge and concrete surface at foundation sill plates. 14" min. gap between plywood edge and concrete surface at foundation sill plates. 12. 3x sill required. 13. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR SHEAR WALLS DESIGNATED AS SW2 & SW4. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan (1) TRIMMER w/ (2) KING STUD (4)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 9 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan D 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 12'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDU2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates minimum shearwall length 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan A 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 0X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan U 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan TYP.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 22'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Indicates shearwall type designation per schedule 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SEIS. GAP PER ARCH.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXISTING 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan MARK 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 10 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan N 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan G 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shear Wall Schedule (SW)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan UNDERPIN EXISTING FOOTING w/ SLURRY TO BOTTOM OF (N) FOOTING AT THE TIME OF (N) FOOTING CONSTRUCTION. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6x6 POST + 2x STUD (5)01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan POST CENTERED POST ABOVE 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 9'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Note 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 10d @ 2" O.C.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1/2" STRUCT. 1 PLY 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 7 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1. ORIENT POST FOR FULL BEAM WIDTH BEARING 2. U.N.O. ATTACH POST TO SILL PLATE PER DETAIL 3/S1.2. 3/S1.2. 3. POSTS ARE CALLED OUT WHERE THEY ORIGINATE. PROVIDE MATCHING POSTS IN LEVELS ABOVE WHERE BEAM OCCURS AT UPPER LEVELS. 4. SISTER MULTI 2x w/ 16d @ 12" o.c. TYP. 5. SISTER 2x TO 6x6 w/ 16d @ 6" o.c. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan STRAP AROUND OPENING IN SHEAR WALL ABOVE PER DETAIL 8/S1.38/S1.3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan T 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan max. spacing 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SINGLE 2x STUD 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S3.1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 11 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan G 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan O 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6x6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan HDUE3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SCALE: 1/4" = 1'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Capacity 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan F 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan E 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan P 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan BALLOON FRAME WALLS TO ROOF AT STAIR WELL 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Shaded region indicates shear wall 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 8 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Wood Posts 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan EXTERIOR WOOD STAIR FRAMING SHALL BE PRESSURE-TREATED, TYP. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan R 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW1 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan SW4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 12 of 13City of San Luis ObispoJanuary 28, 2026 PERMIT CORRECTIONS REPORT (BLDG-2981-2025) yhassan 34'-0"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Foundation Plan 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 1,2,3 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan .01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan L 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 44 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Nailing 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 4x6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 12" o.c.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Fax (805) 548-8601 Fax (805) 548-8601 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan S 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 66 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 0Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 510 plf 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 9Y 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 6 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 2'-9"01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan Sheathing Material 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan REVISE NOTE AS NO GEOTECHNICAL REPORT WAS PROVIDED. 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan I 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan V 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 22X 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 46 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan TYP.01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 yhassan 5 01/16/2026 7:12 pm 619 Grove Street - 1st Building Submittal - 25.1222.pdf 24 Page 13 of 13City of San Luis ObispoJanuary 28, 2026 BUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC – www.energysoft.com. Grove Street ADU 2238 Bayview Heights Drive, Suite E , Carstairs Energy Inc. Timothy Carstairs, CEA, HERS, GPR San Luis Obispo, CA 93401 12/16/2025 25-121617 Los Osos, CA 93402 805-904-9048 619 Grove Street November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 TABLE OF CONTENTS 3 1 20 Form MF1R Mandatory Measures Summary Table of Contents 2 Room Load Summary Form RMS-1 Residential Measures Summary 14 Form CF1R-PRF-01-E Certificate of Compliance Cover Page 15 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 1 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 GENERAL INFORMATION 01 Project Name Grove Street ADU 02 Run Title Title 24 Analysis 03 Project Location 619 Grove Street 04 City San Luis Obispo 05 Standards Version 2022 06 Zip code 93401 07 Software Version EnergyPro 9.4 08 Climate Zone 5 09 Front Orientation (deg/ Cardinal)180 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)920 19 Glazing Percentage (%)13.15% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type All electric 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 2 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 35 29 49.6 Proposed Design 32.3 23 46.3 2.7 6 3.3 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 0.00 kWdc •PV System(s) removed due to Reduced PV Requirement of 0 kWdc 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 3 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr)Margin (EDR1)Margin (EDR2) Space Heating 2.53 17.21 2.54 20.58 -0.01 -3.37 Space Cooling 0.03 1.46 0.02 0.98 0.01 0.48 IAQ Ventilation 0.47 5.11 0.47 5.11 0 0 Water Heating 3.28 36.02 1.97 20.91 1.31 15.11 Self Utilization/Flexibility Credit 0 0 0 0 Efficiency Compliance Total 6.31 59.8 5 47.58 1.31 12.22 Photovoltaics 0 0 0 0 Battery 0 0 Flexibility 0 Indoor Lighting 0.88 9.4 0.88 9.4 Appl. & Cooking 4.29 53.67 4.26 53.33 Plug Loads 5.92 63.49 5.92 63.49 Outdoor Lighting 0.2 1.97 0.2 1.97 TOTAL COMPLIANCE 17.6 188.33 16.26 175.77 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 4 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 23.16 21.41 1.75 7.56 Net EUI2 23.16 21.41 1.75 7.56 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 0 No PV - required PV less than 1.8kWdc Standard (14-17%)Fixed none true n/a n/a n/a n/a n/a REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV exception 2: No PV required when minimum PV size (Section 150.1(c)14) < 1.8 kWdc (0 kW) •Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed •One or more heat pump water heaters have been modeled as demand response compatible 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 5 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Indoor air quality ventilation •Kitchen range hood •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Airflow in habitable rooms (SC3.1.4.1.7) •Verified HSPF •Verified heat pump rated heating capacity •Wall-mounted thermostat in zones greater than 150 ft2 (SC3.4.5) •Ductless indoor units located entirely in conditioned space (SC3.1.4.1.8) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Grove Street ADU 920 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Area Conditioned HVAC System1 920 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front Wall Living Area R21 Wall 180 Front 152 46 90 Left Wall Living Area R21 Wall 270 Left 272 23.5 90 Rear Wall Living Area R21 Wall 0 Back 152 0 90 Right Wall Living Area R21 Wall 90 Right 272 0 90 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 6 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front Wall 2 Living Area R21 Wall 180 Front 152 32 90 Left Wall 2 Living Area R21 Wall 270 Left 272 39.5 90 Rear Wall 2 Living Area R21 Wall 0 Back 152 0 90 Right Wall 2 Living Area R21 Wall 90 Right 272 0 90 Roof Living Area R-30 Roof Attic n/a n/a 60 n/a n/a Roof 2 Living Area R-30 Roof Attic n/a n/a 430 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Area Attic RoofLiving Area Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window B Window Front Wall Front 180 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window D Window Front Wall Front 180 1 10 0.3 NFRC 0.35 NFRC Bug Screen Window C Window Left Wall Left 270 1 7.5 0.3 NFRC 0.35 NFRC Bug Screen Window A Window Left Wall Left 270 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window A 2 Window Front Wall 2 Front 180 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window A 3 Window Front Wall 2 Front 180 1 16 0.3 NFRC 0.35 NFRC Bug Screen Window A 4 Window Left Wall 2 Left 270 1 16 0.3 NFRC 0.35 NFRC Bug Screen 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 7 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window C 2 Window Left Wall 2 Left 270 1 7.5 0.3 NFRC 0.35 NFRC Bug Screen Window A 5 Window Left Wall 2 Left 270 1 16 0.3 NFRC 0.35 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door 1 Front Wall 20 0.5 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab Living Area 490 106 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Attic RoofLiving Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 8 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-30 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032 Over Ceiling Joists: R-20.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Not Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 50 Rheem XE50T10H22U0 (50 gal, JA13)Outside Living Area Living Area 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 9 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name HVAC System1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 n/a n/a HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 VCHP-ductless 1 HSPF 9.5 12500 10000 EERSEER 16 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Required Required Yes Yes Yes Yes 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 10 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Name Certified Low-Static VCHP System Airflow to Habitable Rooms Ductless Units in Conditioned Space Wall Mount Thermostat Air Filter Sizing &amp; Pressure Drop Rating Low Leakage Ducts in Conditioned Space Minimum Airflow per RA3.3 and SC3.3.3.4.1 Certified non-continuous Fan Indoor Fan not Running Continuously Heat Pump System 1 Not required Required Required Required Not required Not required Not required Not required Not required INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 56 0.35 Exhaust No n/a / n/a No Yes 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:Grove Street ADU Calculation Date/Time:2025-12-22T07:01:44-08:00 (Page 11 of 11) Calculation Description:Title 24 Analysis Input File Name:Grove Street ADU (619).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-12-22   07:02:04 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Timothy Carstairs Carstairs Energy Inc.12/22/2025 2238 Bayview Heights Dr STE E CEA 2022 Los Osos, CA 93402 8059049048 CHRISTOPHER ALLEN CWA Studios 12/22/2025 1668 Sydney Street C35818 San Luis Obispo, CA 93401 8052865186 425-P010379374A-000-000-0000000-0000 12/22/2025 07:32 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type  Single Family  Addition Alone Date  Multi Family  Existing+ Addition/Alteration Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units INSULATION Area Construction Type Cavity (ft2) Special Features Status FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status New Page 14 of 20 12/16/2025 13.2% New Grove Street ADU none n/a 121 n/a CA Climate Zone 05 63.0 1 Heat Pump Perim = 106' New 1 New 4 HVAC System Ductless / with Fan Slab Opaque Door Roof - no insulation - Wood Framed Attic R 30 New 0.300 0.35 920 40 N/A 3.10 New - no insulation - Ductless 16.0 SEER 20 1,555 none none 1 none Electric Heat Pump Standard Left (W) Front (S)58.0 n/a New 490 New Door Wall Wood Framed 619 Grove Street San Luis Obispo N/A 9.50 HSPF 0.30 Split Heat Pump User Number: 6249 0.300 0.35 Setback New ID: 25-121617 R 21 Unheated Slab-on-Grade EnergyPro 9.4 by EnergySoft 490 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. (04/2022) Building Envelope: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. * § 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. * § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, gasketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services (BHGS). § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R. § 110.8(j): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. § 150.0(a): Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area-weighted average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood-frame ceiling; or area-weighted average U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area-weighted average U-factor of 0.054 or less. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. * § 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value. § 150.0(c): Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B. * § 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. * § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(g)1: Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to §150.0(d). § 150.0(g)2: Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. § 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.45; or area-weighted average U-factor of all fenestration must not exceed 0.45. * Fireplaces, Decorative Gas Appliances, and Gas Log: § 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)1: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device. * § 150.0(e)3: Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control. * Space Conditioning, Water Heating, and Plumbing System: § 110.0-§ 110.3: Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the California Energy Commission. * § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N. * § 110.2(b): Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. * § 110.2(c): Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat. * § 110.3(c)3: Insulation. Unfired service water heater storage tanks and solar water-heating backup tanks must have adequate insulation, or tank surface heat loss rating. § 110.3(c)6: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters. * § 150.0(h)1: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer. § 150.0(h)3B: Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer’s instructions. § 150.0(j)1: Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in § 609.11 of the California Plumbing Code. * § 150.0(j)2: Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment` maintenance, and wind as required by §120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. § 150.0(n)1: Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must designate a space at least 2.5’ x 2.5’ x 7’ suitable for the future installation of a heat pump water heater, and meet electrical and plumbing requirements, based on the distance between this designated space and the water heater location; and a condensate drain no more than 2” higher than the base of the water heater § 150.0(n)3: Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the executive director. Ducts and Fans: § 110.8(d)3: Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. § 150.0(m)1: CMC Compliance. All air-distribution system ducts and plenums must meet CMC §§ 601.0-605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to R-6.0 or higher; ducts located entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8) do not require insulation. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable UL requirements, or aerosol sealant that meets UL 723. The combination of mastic and either mesh or tape must be used to seal openings greater than ¼”, If mastic or tape is used. Building cavities, air handler support platforms, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts; ducts installed in these spaces must not be compressed. * § 150.0(m)2: Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. § 150.0(m)9: Protection of Insulation. Insulation must be protected from damage due tosunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service (e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover). Cellular foam insulation must be protected as above or painted with a water retardant and solar radiation-resistant coating. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner cores of flex ducts must have a non-porous layer or air barrier between the inner core and outer vapor barrier. § 150.0(m)11: Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.1. § 150.0(m)12: Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Clean-filter pressure drop and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service. Filter racks or grilles must use gaskets, sealing, or other means to close gaps around the inserted filters to and prevents air from bypassing the filter. * 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(m)13: Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ≥ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air handlers and ≤ 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3. * Ventilation and Indoor Air Quality: § 150.0(o)1: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * § 150.0(o)1B: Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for compliance with §150.0(o)1C. § 150.0(o)1C: Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . Single-family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. § 150.0(o)1G: Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per §150.0(o)1Gvi. * § 150.0(o)1H&I: Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per § 150.0(o)1C must be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the minimum airflow rate required by §150.0(o)1C. § 150.0(o)2: Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow rates and sound requirements per §150.0(o)1G Pool and Spa Systems and Equipment: § 110.4(a): Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating. * § 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * Lighting: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9. * § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kitchen range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen closets with an efficacy of at least 45 lumens per watt. § 150.0(k)1B: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. § 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1E: Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. § 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k). * 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * § 150.0(k)1H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. § 150.0(k)1I: Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems. * § 150.0(k)2A: Accessible Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually turned on and off. * § 150.0(k)2B: Multiple Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the dimmer or sensor is installed to comply with § 150.0(k). § 150.0(k)2C: Mandatory Requirements. Lighting controls must comply with the applicable requirements of § 110.9. § 150.0(k)2D: Energy Management Control Systems. An energy management control system (EMCS) may be used to comply with dimming, occupancy, and control requirements if it provides the functionality of the specified control per § 110.9 and the physical controls specified in § 150.0(k)2A. § 150.0(k)2E: Automatic Shutoff Controls. In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire must be controlled by an occupancy or vacancy sensor providing automatic-off functionality. Lighting inside drawers and cabinets with opaque fronts or doors must have controls that turn the light off when the drawer or door is closed. § 150.0(k)2F: Dimmers. Lighting in habitable spaces (e.g., living rooms, dining rooms, kitchens, and bedrooms) must have readily accessible wall-mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers controlling LED light sources in these spaces must comply with NEMA SSL 7A. § 150.0(k)2K: Independent controls. Integrated lighting of exhaust fans shall be controlled independently from the fans. Lighting under cabinets or shelves, lighting in display cabinets, and switched outlets must be controlled separately from ceiling-installed lighting. § 150.0(k)3A: Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must have a manual on/off switch and either a photocell and motion sensor or automatic time switch control) or an astronomical time clock. An energy management control system that provides the specified control functionality and meets all applicable requirements may be used to meet these requirements. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must either comply with § 140.8 or consume no more than 5 watts of power. § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Solar Readiness: § 110.10(a)1: Single-family Residences. Single-family residences located in subdivisions with 10 or more single-family residences and where the application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b)-(e). §110.10(b)1A: Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas greater than 10,000 square feet. For single-family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. * § 110.10(b)2: Azimuth. All sections of the solar zone located on steep-sloped roofs must have an azimuth between 90-300° of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment. * § 110.10(b)3B: Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the horizontal distance of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. * § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. § 110.10(c): Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single-family residences and central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b)-(c) must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. § 110.10(e)2: Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric.” Electric and Energy Storage Ready: 2022 Single-Family Residential Mandatory Requirements Summary 5/6/22 § 150.0(s) Energy Storage System (ESS) Ready. All single-family residences must meet all of the following: Either ESS-ready interconnection equipment with backed up capacity of 60 amps or more and four or more ESS supplied branch circuits, or a dedicated raceway from the main service to a subpanel that supplies the branch circuits in § 150.0(s); at least four branch circuits must be identified and have their source collocated at a single panelboard suitable to be supplied by the ESS, with one circuit supplying the refrigerator, one lighting circuit near the primary exit, and one circuit supplying a sleeping room receptacle outlet; main panelboard must have a minimum busbar rating of 225 amps; sufficient space must be reserved to allow future installation of a system isolation equipment/transfer switch within 3’ of the main panelboard, with raceways installed between the panelboard and the switch location to allow the connection of backup power source. § 150.0(t) Heat Pump Space Heater Ready. Systems using gas or propane furnaces to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the furnace with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(u) Electric Cooktop Ready. Systems using gas or propane cooktop to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the cooktop with circuit conductors rated at least 50 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” § 150.0(v) Electric Clothes Dryer Ready. Clothes dryer locations with gas or propane plumbing to serve individual dwelling units must include: A dedicated unobstructed 240V branch circuit wiring installed within 3’ of the dryer location with circuit conductors rated at least 30 amps with the blank cover identified as “240V ready;” and a reserved main electrical service panel space to allow for the installation of a double pole circuit breaker permanently marked as “For Future 240V use.” *Exceptions may apply. ROOM LOAD SUMMARY Project Name Date System Name Floor Area ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible PAGE TOTAL TOTAL * * Total includes ventilation load for zonal systems. 372 52 372 1 112 59 4,4941 7,938 112 Living Area 161 178 211 7,938 290 HVAC System 7,0153,444 290 211 113 161 12/16/2025 1st Floor 4,4484,494 Grove Street ADU 920 11,463 11,463 2nd Floor 59 3,444 52 Hydraulic Calculation Check — 619 Grove Street, San Luis Obispo, CA (10-yr, 25-yr, 50-yr, 100-yr), Rational Method + 2" PVC Hydraulics Contributing Area = 1,041 sf; Runoff Composite Coefficient 𝐶𝐶= 0.55 1) Inputs / Assumptions Site / Hydrology • Contributing drainage area, 𝐴𝐴= 1,041 ft² • Runoff coefficient, 𝐶𝐶= 0.55 (Table 4-7) • Method: Rational Method (peak runoff rate) • Rainfall intensity source: SLO Creek Drainage Design Manual (Feb 2003), Table 4-6 (558–609 mm /hr annual rainfall band), 10-minute duration: o 10-year: 𝑖𝑖10 =91 mm/hr o 25-year: 𝑖𝑖25 =102 mm/hr o 50-year: 𝑖𝑖50 =117 mm/hr o 100-year: 𝑖𝑖50 =127 mm/hr Pump / Discharge • Pipe: 2" PVC (assume 2" Sch 40 ID ≈ 2.067 in) • Straight pipe length, 𝐿𝐿= 60 ft • Static head (lift), 𝐻𝐻𝑠𝑠= 0.6 ft • Friction equation: Hazen–Williams, PVC 𝐶𝐶𝐻𝐻𝐻𝐻=150(typical smooth PVC) • Minor loss: (1) 90° elbow, assume 𝐾𝐾= 0.9(typical value; varies by elbow radius/type) Design criterion • “satisfactory pump rate with rainfall totals” interpreted as: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝≥ 𝑄𝑄𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖, 𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝 (i.e., pump discharge rate at operating head must be at least peak runoff inflow rate) 2) Conversions 2.1 Area in acres 𝐴𝐴=104143560 = 0.02390 ac November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 2.2 Rainfall intensity conversion (mm/hr to in/hr) 𝑖𝑖(in/hr)=𝑖𝑖(mm/hr)25.4 𝑖𝑖10 =9125.4 = 3.583 in/hr;𝑖𝑖25 =10225.4 = 4.0157 in/hr; 𝑖𝑖50 =11725.4 = 4.6062 in/hr; 𝑖𝑖100 =12725.4 = 5.0 in/hr 3) Peak runoff inflow (Rational Method) Rational Method (US customary): 𝑄𝑄(cfs)= 1.008 𝐶𝐶𝑖𝑖�𝑖𝑖𝑖𝑖ℎ𝑟𝑟�𝐴𝐴(𝑎𝑎𝑎𝑎)𝐶𝐶a Convert to gpm: 𝑄𝑄(gpm) =𝑄𝑄(cfs) × 448.83 3.1 10-year peak inflow 𝑄𝑄10 = 1.008(0.55)(3.583)(0.0239)(1.0) = 0.04748 cfs 𝑄𝑄10 = 0.04748 × 448.83 =21.31 gpm 3.2 25-year peak inflow 𝑄𝑄25 = 1.008(0.55)(4.0157)(0.0239)(1.1) = 0.05853 cfs 𝑄𝑄25 = 0.05853 × 448.83 =26.27 gpm 3.3 50-year peak inflow 𝑄𝑄10 = 1.008(0.55)(4.6062)(0.0239) = 0.07324 cfs 𝑄𝑄10 = 0.07324 × 448.83 =32.87 gpm 3.4 100-year peak inflow 𝑄𝑄25 = 1.008(0.55)(5.0)(0.0239)(1.25) = 0.08281 cfs 𝑄𝑄25 = 0.08281 × 448.83 =37.17 gpm Minimum pump flow to “keep up” with peak runoff (hydrology requirement): • 10-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥21.31 gpm • 25-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥26.27 gpm • 50-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥32.87 gpm • 100-yr storm: 𝑄𝑄𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝, 𝑝𝑝𝑖𝑖𝑖𝑖≥37.17 gpm Rainfall intensities source: SLO Creek Drainage Design Manual Table 4-5. 4) Hydraulic head requirement through 2" PVC (60 ft + 1 elbow) 4.1 Straight-pipe friction (Hazen–Williams; 60 ft) Hazen–Williams headloss (ft): ℎ𝑖𝑖=4.52 𝐿𝐿 𝑄𝑄1.85𝐶𝐶𝐻𝐻𝐻𝐻1.85  𝑑𝑑4.87 Where: • 𝐿𝐿=60 ft • 𝑄𝑄in gpm • 𝐶𝐶𝐻𝐻𝐻𝐻=150 • 𝑑𝑑=2.067 in Computed straight-pipe friction losses: • At 21.31 gpm: ℎ𝑖𝑖≈0.213 ft • At 26.27 gpm: ℎ𝑖𝑖≈0.314 ft • At 32.87 gpm: ℎ𝑖𝑖≈0.477 ft • At 37.17 gpm: ℎ𝑖𝑖≈0.595 ft 4.2 Elbow minor loss (1 elbow) Minor loss: ℎ𝑝𝑝=𝐾𝐾𝑣𝑣22𝑔𝑔 Using 𝐾𝐾=0.9, 𝑔𝑔=32.2 ft/s2 , 2" Sch 40 ID ≈ 2.067 in: • Velocity at 21.31 gpm: 𝑣𝑣≈2.04 ft/s ℎ𝑝𝑝,10 ≈0.058 ft • Velocity at 26.27 gpm: 𝑣𝑣 ≈2.51 ft/s ℎ𝑝𝑝,25 ≈0.088 ft • Velocity at 32.87 gpm: 𝑣𝑣 ≈3.14 ft/s ℎ𝑝𝑝,10 ≈0.137 ft • Velocity at 37.17 gpm: 𝑣𝑣 ≈3.55 ft/s ℎ𝑝𝑝,10 ≈0.175 ft 4.3 Total Dynamic Head (TDH) 𝑇𝑇𝑇𝑇𝐻𝐻=𝐻𝐻𝑠𝑠+ℎ𝑖𝑖+ℎ𝑝𝑝 with 𝐻𝐻𝑠𝑠= 0.6 ft • 10-yr TDH @ 21.31 gpm 𝑇𝑇𝑇𝑇𝐻𝐻10 = 0.6 + 0.213 + 0.058 = 0.871 ft • 25-yr TDH @ 26.27 gpm 𝑇𝑇𝑇𝑇𝐻𝐻25 = 0.6 + 0.314 + 0.088 = 1.002 ft • 50-yr TDH @ 32.87 gpm 𝑇𝑇𝑇𝑇𝐻𝐻50 = 0.6 + 0.477 + 0.137 = 1.214 ft • 100-yr TDH @ 37.17 gpm 𝑇𝑇𝑇𝑇𝐻𝐻100 = 0.6 + 0.595 + 0.175 = 1.37 ft 5) Minimum pump “size” stated as duty points (Flow @ Head) To keep up with peak runoff inflow: Design Storm Intensity basis (10- min) Antecedent Moisture Factor (Ca) Runoff coeff. 𝐶𝐶 Peak inflow 𝑄𝑄𝑖𝑖𝑖𝑖(gpm) Static head (ft) 60 ft 2" friction (ft) 1 elbow minor (ft) TDH (ft) Minimum pump duty point 10-year 91 mm/hr 1.0 0.55 21.31 0.6 0.213 0.058 0.871 ≥ 21.4 gpm @ ~0.9 ft TDH 25-year 102 mm/hr 1.1 0.55 26.27 0.6 0.314 0.088 1.002 ≥ 26.3 gpm @ ~1.1 ft TDH 50-year 117 mm/hr 1.2 0.55 32.87 0.6 0.477 0.137 1.214 ≥ 32.9 gpm @ ~1.3 ft TDH 100- year 127 mm/hr 1.25 0.55 37.17 0.6 0.595 0.175 1.37 ≥ 37.2 gpm @ ~1.4 ft TDH Rainfall intensity source: SLO Creek Drainage Design Manual Table 4-6 for City of SLO. 6) Notes / Limitations for engineering review 1. TDH includes only: 0.6 ft static lift + 60 ft straight 2" pipe + one elbow. Any additional fittings (check valve, reducer, discharge losses, etc.) will add head. 2. Rational Method peak runoff depends on selected duration (typically near time of concentration). This check uses 10-minute intensity as a conservative short-duration basis per Table 4-6 for City of SLO. DESCRIPTION THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW 2-STORY 920 SQ. FT. ATTACHED ACCESSORY DWELLING UNIT AT THE REAR OF AN EXISTING SINGLE FAMILY DWELLING. SITE INFORMATION EXISTING BUILDING INFORMATION JURISDICTION ZONING APN STREET ADDRESS GROSS LOT SIZE BUILDING AREAS PROPOSED INFORMATION TWONUMBER OF STORIES R-3 (RESIDENTIAL)OCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE SPRINKLERED CLASS A ROOFINGROOF RATING TWO STORYNUMBER OF STORIES R-3 (RESIDENTIAL) / UOCCUPANCY TYPE V B (NON-RATED)CONSTRUCTION TYPE NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSEDFIRE SPRINKLERS CITY OF SAN LUIS OBISPO LOW DENSITY RESIDENTIAL (R-1) 001-056-052 619 A GROVE STREET, SAN LUIS OBISPO, CA 93401 0.08 ACRES (3,589 SF) CLASS AROOF RATING 25 FEET ALLOWEDMAXIMUM HEIGHT PROPERTY IS NOT LOCATED WITHIN A HIGH FIRE RISK AREA OR FLOOD PLAIN AREAHAZARDS LOT COVERAGE MAX 40% = 3,589 X 0.4 = 1,436 SF. PROPOSED = 862 SF. 862 / 3,589 = 24% (ADU EXCLUDED FROM LOT COVERAGE CALCULATIONS PER MC § 17.70.120(B)(5)) 1 SPACE PROVIDED IN DRIVEWAY PER PREVIOUS LOT SPLITPARKING LEGAL DESCRIPTION CY SLO PM 84/92-93 PAR 2 1 SPACE PROVIDED IN DRIVEWAYPARKING NO, SPRINKLERS ARE NOT PRESENT, NOR ARE THEY PROPOSED T1.0 Title Sheet, General Notes + Project Data Sheet Index OWNER Project Directory SOILS ARCHITECT CWA STUDIOS 1668 SYDNEY STREET SAN LUIS OBISPO. CA 93401 CONTACT: CHRIS ALLEN, AIA. 805 286 5186 Drawing Log SET ISSUE DATE REVISION Project Notes ENERGY CARSTAIRS ENERGY CALCULATIONS 2238 BAYVIEW HEIGHTS DRIVE, SUITE E LOS OSOS, CA 93402 CONTACT: TIM CARSTAIRS. 805 904 9048 Project Data T1.1 INDEX, DATA + NOTES STRUCTURAL Calgreen Mandatory Measures 1.PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL SHALL MANAGE STORMWATER DURING CONSTRUCTION. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. CALGREEN 4.106.2.2 2.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED AND SHALL COMPLY WITH THE PLUMBING FIXTURE AND FITTINGS SCHEDULE ON THIS SHEET. CALGREEN 4.303.3.1 3.AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1 - CONTROLLERS SHALL BE WEATHER- OR SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANT WATERING NEEDS AS WEATHER OR SOIL CONDITIONS CHANGE. 2 - WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). CALGREEN 4.304.1 4.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE CLOSED WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY TO PREVENT PASSAGE OF RODENTS. CALGREEN 4.406.1. 5.RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 60% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4; OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. CALGREEN 4.408.1 6.DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION PER CALGREEN 4.504.1. 7.ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS PER CALGREEN 4.504.2.1. 8.PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.2.2. 9.AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS PER CALGREEN 4.504.2.3. 10.DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED PER CALGREEN 4.504.2.4. 11.CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS PER CALGREEN 4.504.3. 12.EIGHTY (80) PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERINGINSTITUTE (RFCI) FLOORSCORE PROGRAM PER CALGREEN 4.504.4. 13.PARTICLEBOARD, MEDIUM FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN INTERIOR OR EXTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS PER CALGREEN 4.504.5. 14.VAPOR RETARDER AND CAPILLARY BREAK OF 4” THICK BASE OF ½” OR LARGER CLEAN AGGREGATE SHALL BE INSTALLED AT SLAB ON GRADE FOUNDATIONS PER CALGREEN 4.505.2. 15.MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING SHALL BE CHECKED BEFORE ENCLOSURE PER CALGREEN 4.505.3. 16.BATHROOM EXHAUST FANS SHALL BE DUCTED TO TERMINATE OUTSIDE AND BE PROVIDED IN EVERY BATHROOM PER CALGREEN 4.506.1. 17.WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED LOUVERS OR COVERS WHICH CLOSE WHEN THE FAN IS OFF. COVERS OR LOUVERS SHALL HAVE A MINIMUM INSULATION VALUE OF R-4.2 PER CALGREEN 4.507.1. 18.PER CALGREEN 4.507.2 DUCT SYSTEMS ARE SIZED, DESIGNED, AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS: 1. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ACCA (MANUAL J) OR EQUIVALENT. 2. SIZE DUCT SYSTEMS ACCORDING TO ACCA 26-D (MANUAL D) OR EQUIVALENT. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S (MANUAL S) OR EQUIVALENT. 19.OPERATION + MAINTENANCE MANUAL TO BE SUPPLIED AT FINAL INSPECTION. 20.MANAGE STORMWATER PER CALGREEN CODE REQUIREMENTS. 4106.2 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 25.1222 Deferred Submittals / Separate Permits 1.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDER-DRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. SURVEY MBS LAND SURVEYS 3559 SOUTH HIGUERA ST. SAN LUIS OBISPO CA 93401 CONTACT: MICHAEL B STANTON 805 594 1960 ARCHITECTURAL1.ALL WORK SHALL BE IN CONFORMANCE WITH THE 2022 EDITIONS OF THE CALIFORNIA BUILDING CODES 2.ANY/ALL DEFERRED SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT AND/OR PROJECT ENGINEER PRIOR TO SUBMISSION TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL. 3.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. 4.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY OR WITHIN CITY EASEMENTS FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. 5.THE PUBLIC IMPROVEMENTS SHALL BE SUBSTANTIALLY COMPLETE TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR PRIOR TO FINAL INSPECTION APPROVALS AND/OR OCCUPANCY OF ANY BUILDING. 6.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER AND SIDEWALK OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. 7.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 805 781 7554 WITH AT LEAST A 48 HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. 8.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. 9.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. 10.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED DURING ALL CONSTRUCTION AND GROUND DISTURBING ACTIVITIES PER THE CITY OF SAN LUIS OBISPO 11.TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED WHEN PERMANENT IMPROVEMENTS, PLANTINGS AND FACILITIES ARE IN PLACE. TEMPORARY MEASURES SHALL BE REMOVED PRIOR TO FINAL INSPECTION APPROVALS. 12.THE EXISTING SEWER LATERAL SHALL BE TELEVISED AND APPROVED FOR REUSE OR SHALL BE REPAIRED/REPLACED. THE INSPECTION SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE UTILITIES DEPARTMENT PRIOR TO ISSUANCE OF A BUILDING PERMIT. 13.ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE VERTICAL AND GREATER AND AREAS USED TO CONVEY CONCENTRATED DRAINAGE SHALL BE PREPARED AND MAINTAINED TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED NO LATER THAN 30 DAYS PRIOR TO A REQUEST FOR FINAL INSPECTION APPROVAL. 14.REMODELING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS A VIOLATION OF CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELERS AND PAINTERS ARE REQUIRED TO USE "LEAD-SAFE" WORK PRACTICES PURSUANT TO TITLE 17, CA CODE OF REGULATIONS SECTION 36050. 15.PRIOR TO ANY DEMOLITION OR GRADING THE CONTRACTOR SHALL PROTECT ANY TREES ADJACENT TO THE WORK ZONE. 16.THE MANDATORY PROVISIONS OF CALGREEN CHAPTER 4 SHALL BE APPLIED TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. CALGREEN 301.1.1 17.ON AND AFTER JANUARY 1, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. CALGREEN 301.1.1 18.APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER ORDINANCE OR LAW. CBC 105.4 19.THIS PROJECT IS LOCATED IN THE HIGH FIRE SEVERITY ZONE AS PER CITY OF SAN LUIS OBISPO California Building Code Chapter 7A Req. THE CITY OF SAN LUIS OBSIPO IS CONSIDERED A "COMMUNITY AT RISK" DUE TO THE THREAT OF WILDFIRE IMPACTING THE URBAN COMMUNITY. THE CITY SHALL CONTINUE TO ENHANCE THE FIRE SAFETY AND CONSTRUCTION CODES FOR NEW BUILDINGS IN ORDER TO REDUCE THE RISK OF URBAN FIRES THAT MAY RESULT FROM WILDFIRES. NEW BUILDINGS CITYWIDE SHALL INCORPORATE THE FOLLOWING CONSTRUCTION METHODS AND MATERIALS: IGNITION RESISTANT EXTERIOR WALL COVERINGS; FIRE SPRINKLER PROTECTION IN ATTIC AREAS (AT LEAST ONE "PILOT HEAD"); EMBER RESISTANT VENT SYSTEMS FOR ATTICS AND UNDER FLOOR AREAS, PROTECTED EAVES AS IDENTIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7A. CRC R337.1.2. STORK, WOLFE & ASSOCIATES 555 CHORRO ST. SUITE A1 SAN LUIS OBISPO, CA 93401 CONTACT: JUSTIN WOLFE, PE. PH: 805 548 8604 STRUCTURAL AS1.1 ARCHITECTURAL SITE PLAN T1.2 A3.1 EXISTING BUILDING ELEVATIONS A5.2 ARCHITECTURAL DETAILS S0.1 STRUCTURAL GENERAL NOTES S1.4 TYPICAL DETAILS S1.2 TYPICAL DETAILS S2.2 S2.3 ROOF FRAMING PLAN SECOND FLOOR FRAMING PLAN S0.2 STRUCTURAL GENERAL NOTES S1.1 TYPICAL DETAILS A4.1 PROPOSED BUILDING SECTIONS S1.3 TYPICAL DETAILS S2.1 FOUNDATION PLAN S3.1 STRUCTURAL DETAILS CALGREEN MANDATORY MEASURES G r o v e S t r e e t R e s i d e n t i a l A d d i t i o n 6 1 9 A G r o v e S t r e e t , S a n L u i s O b i s p o , C A 9 3 4 0 1 A5.1 ARCHITECTURAL DETAILS N/A T1.3 CALGREEN MANDATORY MEASURES Vicinity Map S3.2 STRUCTURAL DETAILS Construction Documents for SV1.1 EXISTING TOPOGRAPHIC SURVEY PROJECT LOCATION CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25BUILDING AREAS (EXISTING) (PROPOSED) PRIMARY RESIDENCE (EXISTING) 1,287 SQ. FT. PROPOSED ADU GROUND FLOOR 490 SQ. FT. SECOND FLOOR 430 SQ. FT. TOTAL (INCLUDING EXISTING RESIDENCE) 2,292 SQ. FT. N/ASOILS REPORT JOHN ROURKE 163 SERRANO HEIGHTS DRIVE SAN LUIS OBISPO. CA 93405 CONTACT: JOHN ROURKE. PH: 805 440 4973 A2.1 PROPOSED FLOOR PLANS + ROOF PLAN A3.2 PROPOSED BUILDING ELEVATIONS AS1.2 ARCHITECTURAL SITE DETAILS Standard Public Works Notes a.ALL WORK LOCATED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN THE JURISDICTION OF THE UTILITIES AND PUBLIC WORKS DEPARTMENTS SHALL COMPLY WITH THE MOST CURRENT EDITION OF THE ENGINEERING STANDARDS AND STANDARD SPECIFICATION. (THE CURRENT ADOPTED STANDARDS ARE DATED DECEMBER 2025. b.A SEPARATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY, WITHIN CITY EASEMENTS, OR FOR CONNECTIONS TO PUBLIC UTILITIES. WORK REQUIRING AN ENCROACHMENT PERMIT INCLUDES BUT IS NOT LIMITED TO DEMOLITIONS, UTILITIES, WATER, SEWER, AND FIRE SERVICE LATERALS, CURB, GUTTER, AND SIDEWALK, DRIVEWAY APPROACHES, SIDEWALK UNDERDRAINS, STORM DRAIN IMPROVEMENTS, STREET TREE PLANTING OR PRUNING, CURB RAMPS, STREET PAVING, AND PEDESTRIAN PROTECTION OR CONSTRUCTION STAGING IN THE RIGHT-OF-WAY. c.ANY SECTIONS OF DAMAGED OR DISPLACED CURB, GUTTER & SIDEWALK, OR DRIVEWAY APPROACH SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE PUBLIC WORKS DIRECTOR. d.CONTACT THE PUBLIC WORKS INSPECTION HOTLINE AT 781-7554 WITH AT LEAST A 48-HOUR NOTICE FOR ANY REQUIRED ENCROACHMENT PERMIT INSPECTION OR FINAL INSPECTION. e.THE ADJOINING STREET SHALL BE CLEANED BY SWEEPING TO REMOVE DIRT, DUST, MUD AND CONSTRUCTION DEBRIS AT THE END OF EACH DAY. f.A TRAFFIC AND PEDESTRIAN CONTROL PLAN SHALL BE SUBMITTED TO THE PUBLIC WORKS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ENCROACHMENT PERMIT ISSUANCE. g.ANY EXISTING SURVEY MONUMENTS SHALL BE PROTECTED IN PLACE OR SHALL BE TIED OUT BY A LICENSED LAND SURVEYOR PRIOR TO DISTURBANCE AND THEN REPLACED PRIOR TO OCCUPANCY IN ACCORDANCE WITH SECTION 8771 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE. h.EROSION CONTROL MEASURES SHALL BE IMPLEMENTED AND MAINTAINED TO THE SATISFACTION OF THE BUILDING OFFICIAL AND PUBLIC WORKS DIRECTOR DURING ALL DEMOLITIONS, CONSTRUCTION AND GROUND DISTURBING ACTIVITIES. i.ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT LESS THAN 2% SHALL HAVE FINAL GRADIENTS CERTIFIED BY A LICENSED SURVEYOR OR ENGINEER PRIOR TO FINAL INSPECTION APPROVALS. Stormwater Compliance Summary THE PROJECT IS NOT A REGULATED PROJECT SUBJECT TO REGIONAL WATER QUALITY CONTROL BOARD RESOLUTION R3-2013-0032 “POST CONSTRUCTION STORMWATER MANAGEMENT REQUIREMENTS FOR DEVELOPMENT PROJECTS IN THE CENTRAL COAST REGION” BASED ON THE FOLLOWING: ☒PROJECT DOES NOT CREATE AND/OR REPLACE 2,500 SQUARE FEET OR MORE OF IMPERVIOUS AREA ☐PROJECT TYPE IS LISTED IN SECTION B.1.B (STATE WHICH): Applicable Governing Codes: 2022 2022 2022 CALIFORNIA BUILDING CODE, VOLUMES 1+2 CALIFORNIA ELECTRIC CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA GREEN BUILDING CODE CALIFORNIA FIRE CODE CALIFORNIA ENERGY CODE CALIFORNIA RESIDENTIAL CODE 2022 2022 2022 2022 2022 SAN LUIS OBISPO MUNICIPAL CODE NOT TO SCALE T1.4 ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS T1.0 A5.3 FIRESTOPPING DETAILS SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0220 HERS Feature Summary THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY A CERTIFIED HERS RATER AS A CONDITION FOR MEETING THE MODELED ENERGY PERFORMANCE FOR THIS COMPUTER ANALYSIS. ADDITIONAL DETAIL IS PROVIDED IN THE BUILDING TABLES ON SHEET T1.3. REGISTERED CF2RS AND CF3RS ARE REQUIRED TO BE COMPLETED IN THE HERS REGISTRY •INDOOR AIR QUALITY VENTILATION •KITCHEN RANGE HOOD •VERIFIED EER/EER2 •VERIFIED SEER/SEER2 •VERIFIED REFRIGERANT CHARGE •AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7) •VERIFIED HSPF •VERIFIED HEAT PUMP RATED HEATING CAPACITY •WALL-MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 FT2 (SC3.4.5) • DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONDITIONED SPACE (SC3.1.4.1.8) A5.4 ARCHITECTURAL DETAILS AS1.0 SITE DEMO / GRADING PLAN MEP2 ELECTRICAL FLOOR PLANS + NOTES ARCHITECTURAL MEP3 MEP CALCULATIONS EXTERIOR LIGHTING COMPLIANCE MEP1 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0305 SUBMITTAL TO THE CITY OF SAN LUIS OBISPO BUILDING / PLANNING DEPARTMENTS 26.0319 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 T1.1 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 Y ALL Y Y ALL Y CONT CONT N/A N/A N/A N/A N/A N/A N/A N/A Y ALL Y OWNER Y ALL Y CONT Y OWNER Y CONT Y CONT Y CONT Y OWNER Y OWNER N/A N/A N/A November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 T1.2 Calgreen Mandatory Measures CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 N/A N/A Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y CONT Y OWNER Y CONT Y CONT Y CONT November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 T1.3 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 T1.4 Energy Compliance Forms CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 SV1.1 Existing Topographic Survey TOPOGRAPHIC MAPJOHN constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 Sheet Reference Notes 1.EXISTING BRICK PAVERS TO BE REMOVED 1 1 1 1 1 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 AS1.0 Site Demo / Grading Plan Sheet Reference Notes 1.PORTION OF DRIVEWAY TO BE REMOVED FOR NEW UTILITIES, SHADED. PAVERS WILL BE PUT BACK IN PLACE ONCE WORK IS COMPLETE 2.NEW TOPOGRAPHY LINES THROUGH SITE GRADING TO ALLOW FOR DRAINAGE TO FLOW TOWARDS THE SUMP PUMP VIA A 1% SLOPE. 3.AREA OF SIDEWALK TO BE REMOVED TO PLACE SIDEWALK UNDER-DRAIN, AND TO BE RESTORED FROM SCORE MARK TO SCORE MARK AFTER DRAIN INSTALLATION IS COMPLETE. 4.DRIVEWAY APPROACH TO BE CONVERTED 331.1' FG. 331.5' FG. 331.6' TG. 331.4' TG. 331.7' FG. 330.0' INV. 331.0' TG. 329.0' INV. 329.0' INV.330331330SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD SDSD SD SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSC.O. C.O. WM 23'-0"12'-0" 35'-0" 70'-0" RIGHT-OF-WAY 22 1 5% SLO P E 2% SLOPE 2% SLOPE3 4 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 168420 Architectural Site Plan11/8" = 1'-0" NEW TREE FOR EACH TREE AUTHORIZED TO BE REMOVED WHEN PLANTED ON THE SAME PROPERTY (ON SITE) OR TWO NEW TREES FOR EACH TREE AUTHORIZED TO BE REMOVED WHEN PLANTED ON A DIFFERENT PROPERTY OR WITHIN THE PUBLIC RIGHT-OF-WAY (OFF SITE). COMPENSATORY PLANTINGS SHALL BE OF A SIZE CONSISTENT WITH CITY ENGINEERING STANDARDS AS SET FORTH IN THE CITY OF SAN LUIS OBISPO MUNICIPAL CODE 12.24.090. DRIP IRRIGATION WILL SERVE THE REPLANTED TREES, USING 1.0 GHP EMITTERS. ALL IRRIGATION WORK SHALL MEET THE REQUIREMENTS OF APPLICABLE STATE AND LOCAL CODES. 311 32 25 19 16 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Architectural Site Details Liberty Grinder Pump Specification1N.T.S. DensGlass Installation Guide - Fastening and Framing N.T.S.3 Sidewalk Underdrain N.T.S.2 AS1.2 CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 MAX). #4 REBAR @ 12" O.C.2" FROM RAINWATER SUMP PUMP, REFER TO SITE PLAN 12" CATCH BASIN, NDS OR EQUAL. 1/4 BEND. November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Proposed Floor Plans, Roof Plan, and Schedules CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 0 1 2 84 1/4" = 1'-0" Proposed First Floor Plan1 0 1 2 84 1/4" = 1'-0" Proposed Second Floor Plan2 A2.1 Floor Plan Reference Notes 1.HARDWOOD VANITY CABINETS 20" DEEP WITH FINISH COUNTER HEIGHT OF +36" A.F.F. . 2.QUARTZITE COUNTERTOP. USE 2CM SLAB THICKNESS AS DROP EDGE CEASARSTONE, OR EQUAL. COLOR TO BE SELECTED BY OWNER. 3.SINK: KOHLER, OR EQUAL. FAUCET: HANSGROHE BATHROOM FAUCET, OR EQUAL. 4.MIRROR FROM TOP OF COUNTER TO CEILING OR PER OWNERS SELECTION. 5.SHOWER HEAD: KOHLER, OR EQUAL. CONTROLS: THERMOSTATIC/PRESSURE BALANCE MIXING VALVE TO PROVIDE SCALD + THERMAL SHOCK PROTECTION. 6.66" PRE-FABRICATED FIBERGLASS TUB. TOP @ 18" A.F.F.. 7.TOILET: LOW-FLOW AMERICAN STANDARD CADET 3, OR EQUAL. 8.GUARDRAILS; SHALL HAVE A MINIMUM HEIGHT OF 42". INTERMEDIATE RAILINGS SHALL BE SPACED AT A MAXIMUM OF 3-3/4". HANDRAILS; SHALL HAVE A HEIGHT OF 36" WHERE LOCATED IN STAIRWAYS. A MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT IS 31-1/2" WHERE A HANDRAIL IS INSTALLED ON ONE SIDE OF THE STAIRWAY, AND 27" WHERE HANDRAILS ARE INSTALLED ON BOTH SIDES. 9.STAIRS, 7-3/4" MAX RISER / 10" MIN. TREAD DEPTH. TO BE IN COMPLIANCE WITH CRC R311.7. 10.NEW FIXTURES PER CALGREEN MANDATORY MEASURES. 11.INFILL WINDOWS IN EXISTING RESIDENCE WITH OPAQUE WALL. 12.6" SEISMIC GAP BETWEEN EXISTING RESIDENCE AND PROPOSED ADU AS SHOWN, REFERENCE DETAIL 7 ON SHEET A5.2 FOR MORE DETAIL. 0 1 2 84 1/4" = 1'-0" Proposed Roof Plan3 Legend X NEW 2X4 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS NEW 2X6 WOOD FRAME CONSTRUCTION, EXTERIOR WALLS SHALL PROVIDE MIN. R-21 INSULATION IN CONFORMANCE WITH ENERGY COMPLIANCE FORMS DOOR / WINDOW CALLOUTS; SEE DOOR & WINDOW SCHEDULE THIS SHEET FOR DETAILS 1-HR RATED ASSEMBLY BETWEEN NEW ACCESSORY DWELLING UNIT AND EXISTING RESIDENCE. NEW RATED WALL SHALL EXTEND FROM CONCRETE SLAB TO BOTTOM OF PROPOSED ROOF SHEATHING IN ALL LOCATIONS. REFERENCE DETAIL 4 & 6 ON A5.2 FOR ADDITIONAL INFORMATION. WINDOW AND DOOR NOTES: 1.ALL EXTERIOR DOORS SHALL BE WEATHER-STRIPPED AND SHALL FEATURE WATER-RESISTANT THRESHOLDS AND/OR DOOR BOTTOMS 2.THRESHOLDS SHALL BE 3/4" MAXIMUM AT SLIDERS AND 1/2" MAXIMUM FOR OTHER DOORS. 3.TEMPERED GLAZING SHALL BE PROVIDED WHERE INDICATED IN THESE PLANS IN ACCORDANCE WITH THE REQUIREMENTS FOR HAZARDOUS LOCATIONS [CBC 2406.3] 4.LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1-½" LOWER THAN TOP OF THRESHOLD. (THE LANDING / FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 7-¾" BELOW TOP OF THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR.) [R311.3.1] 5.PROVIDE LOCKSETS AND DEADBOLTS ON ALL EXTERIOR HINGED DOORS. 6.WINDOWS THAT SERVE AS A REQUIRED MEANS OF EGRESS ARE DENOTED ON THE EXTERIOR ELEVATIONS. EGRESS WINDOWS SHALL HAVE A MAX DIMENSION OF 44" TO THE OPENING ABOVE THE FLOOR, PROVIDE 5.7 SQUARE FEET OF CLEAR EGRESS AREA WITH 24" MIN. HEIGHT AND 20" MIN. WIDTH. Window Schedule WIDTH HEIGHT FRAMETYPE A 4'-0" B HEADER +80" Door Schedule WIDTH HEIGHT FRAME PANELTYPE 6'-8"EXTERIOR - HINGED 2 1 # # VINYL4'-0" GLAZED, TEMPEREDWOOD 3'-8"2'-6" +80" 3'-0" 6'-8" INTERIOR - HINGED 3 S.C. SLABWOOD 2'-8" VINYLSLIDING SLIDING INTERIOR - HINGED A CLASS "A" COMP SHINGLE ROOFING TO MATCH EXISTING. PRODUCT SHALL MEET OR EXCEED UL 790 (CLASS A FIRE RESISTANCE STANDARD). A DRIP EDGE SHALL BE PROVIDED AT EAVES AND RAKE EDGES OF SHINGLE ROOFS PER R905.2.8.5. 3.METAL GUTTER AND DOWNSPOUT PROVIDED, AS REQUIRED. LOWER ROOF DRAINS TO CONNECT TO LEADERS DOWN TO SITE DRAINAGE CONNECTIONS. INLET SHALL BE EQUIPPED WITH A LEAF STRAINER TO PROHIBIT DEBRIS FROM ENTERING THE DOWNSPOUT. 1 1 2 2 2 3 3 1'-7"1'-10 1/2"1'-10 1/2"1'-10 1/2"1'-8"1'-8"3'-2" 3'-2"3'-1"6" SEISMICGAPLIVING ROOM 101 KITCHEN 102BATH 105 BEDROOM 106 LAUNDRY 104 HALL 103 BATH 203 BEDROOM 202 HALL 201 1/A4.11/A4.1BEDROOM 204 BEDROOM 205 6'-8"4 3'-0"INTERIOR - HINGED S.C. SLABWOOD November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 A3.1 Existing Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S. 4 D 3/4 D 3/4 D 4 D 1 A 2 F 2 F 6 C 8 - 10 - November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 A3.2 Proposed Building Elevations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S. FIRST LEVEL (0'-0") (FF = 333') F.F. @ SECOND LEVEL (9'-0")(FF = 342') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 A4.1 Proposed Building Sections CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S. -0") TOP PLATE OF WALL (17'-0") WINDOW & DOOR HEADERS (15'-8") AVERAGE NATURAL GRADE (-1'-6")(FG = 331.5') November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Architectural Details CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. Penetrations and Firestopping NOT TO SCALE Bi-Pass Door - Head and Jamb Typical Jamb, Head, and Sill Installation @ Exterior Windows + Doors 3" = 1'-0" 5 1 Through Wall Penetrations and Firestopping N.T.S.4 SYSTEM NO. W-L-1054NOT TO SCALE November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 8 3" = 1'-0" 6 A5.2 EXTERIOR 7/8" 3-COAT CEMENTIOUS PLASTER SIDING OVER MIN. TWO LAYERS GRADE D BUILDING PAPER. November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Firestopping Details A5.3 CAD FILE CWA JOB NO DRAWN BY PLOT DATE 2020 1 sheet: sheet data: revision: sheet title: REV DESCRIPTION BYISSUE DATE SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1 SYDNEY STREET, SLO, CA 3401 EMAIL CWA.ARCH GMAIL.COM TELEPHONE 0.2.1 AIA, LEED AP, C-31 CHRISTOPHER W. ALLEN C31 EXP. 0.30.2LIC E N S E D A RCHITE C TS TATE OF C A L I F O R N IA12/22/2 2.031 legal stuff: THE USE OF THES E PLANS AND SPECIFICAT IONS SHALL BE RESTRICTED TO THE USE OF THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE UNLESS OTHERWISE APPROVED BY THE A RC HITECT. TITL E TO T HES E P LA NS AN D S PE CIFI CA T IO NS REMAINS WITH CWA STUDIOS WITHOUT PREJUDICE. VISUAL CONTAC T W ITH TH E SE P LANS AND S PE CI F ICATI O NS S HA LL CONSTITUTE PRIMA FACE EVIDENCE OF THE ACCEPTANCE OF T HES E R EST R I CT ION S. C 2 02  C W A S T U DI O S SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/2 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/0/2 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/1/2 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 NOSING CONTRASTING 2" (MIN.) TO 4" (MAX.) WIDE STRIPE SET STRIPE NO MORE THAN 1" FROM EDGE OF NOSING 7" RISER10-3/4" 3/4" November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 OCCUPANT SENSORS W/ INTEGRAL PHOTO CONTROL CERTIFIED TO COMPLY W/ SECTION 119(D). General Lighting Notes 3'-8 1/4" 3'-8 1/4" November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 WHOLE-BUILDING VENTILATION REQUIREMENTS (FROM ASHRAE 62.2) AT LEAST ONE MECHANICAL VENTILATION SYSTEM IN THE BUILDING MUST BE DESIGNATED FOR USE IN COMPLIANCE WITH THE WHOLE- BUILDING VENTILATION REQUIREMENT. ALTERNATIVELY, THE SUM OF THE RATED AIR FLOWS FROM MULTIPLE FANS CAN BE UTILIZED TO MEET THE REQUIRED WHOLE BUILDING VENTILATION AIRFLOW. THE SYSTEM(S) MUST DELIVER CONTINUOUS VENTILATION AIRFLOW AT A RATE GREATER THAN OR EQUAL TO THE RATE SPECIFIED IN EQUATION 4.1a, AND FAN SONE RATINGS MUST NOT EXCEED 1.0. FOR DWELLING OCCUPANT DENSITIES KNOWN TO BE GREATER THAN (NBR + 1), THE RATE SHALL BE INCREASED BY 7.5 CFM FOR EACH ADDNL PERSON. Whole House Ventilation Calculation FLOOR AREA (SF)NBR OF BR QFAN (cfm) 920 4 50.40 MEP2 MEP Calculations CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 Residential Load Calculations RESIDENTIAL LOAD CALCULATIONS (NEC 220.82) OPTIONAL METHOD NEC 220-30 As an optional method, the STANDARD METHOD, found in ARTICLE 220 of the National Electric Code, may be used 1 GENERAL LIGHTING NOTES SF X 3 VA / SF 920 SF 2760 VA SMALL APPLIANCE LOADS - 220-16 (a) (MIN. 2)1500 VA 3000 VA LAUNDRY LOADS 1500 VA 1500 VA SUBTOTAL 7260 VA 2 COOKING EQPT. LOADS - (NAMEPLATEVALUE) RANGE 5000 VA 5000 VA COOKTOP --VA 0 VA OVEN 0 VA 0 VA SUBTOTAL 5000 VA 3 ELECTRICAL DRYER 220-18 (NAMEPLATE, 5,00 VA MIN) DRYER 5000 VA 5000 VA SUBTOTAL 5000 VA 4 FIXED APPLIANCE LOADS- 230-30(b3) DISHWASHER 0 VA 0 VA DISPOSAL 1140 VA 1140 VA COMPACTOR --VA 0 VA WATER HEATER 0 VA 0 VA HYDROMASSAGE BATHTUB --VA 0 VA MICROWAVE 1500 VA 1500 VA BUILT -IN VACUUM 0 VA 0 VA SUBTOTAL 2640 VA 5 OPTIONAL SUBTOTAL (ADD ALL OF THE ABOVE TOTALS)19900 VA 6 APPLYING DEMAND FACTORS -TABLE 220-30 FIRST 10,000VA @ 100%10,000 VA REMAINING VA @ 40% (SUBTOTAL ABOVE - 10,000) X 40%3960 VA 7 HEATING OR AC LOAD - TABLE 220-30 10000 LARGER OF THE HEATING OR AC LOAD 0 VA 8 POOL PANLE/EQUIPMENT 0 VA 9 OPTIONAL TOTAL VOLT AMPS (ADD TOTAL FROM LINE 6+7)23960 VA 10 MINIMUM SERVICE SIZE (OPTIONAL LOAD TOTAL VA /240 VOLTS) =100 AMPS SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS A.PURPOSE 1.THE FOLLOWING INFORMATION INCLUDES THE BASIC PERMIT APPLICATION REQUIREMENTS FOR A 120/240 VOLT SINGLE PHASE ELECTRICAL SERVICE RATED GREATER THAN 200 AMPERES, BUT NOT OVER 600 AMPERES, INSTALLED ON A SINGLE FAMILY RESIDENTIAL LOT. 2.CAUTION: THIS HANDOUT AND THE NATIONAL ELECTRICAL CODE ARE NOT INTENDED AS DESIGN SPECIFICATIONS NOR INSTRUCTION MANUALS FOR UNTRAINED PERSONS. NEC 90.1(C). THE NATIONAL ELECTRICAL CODE REQUIRES QUALIFIED PERSONS TO DESIGN ELECTRICAL INSTALLATIONS. B.SCOPE 1.IN GENERAL, THE ELECTRICAL EQUIPMENT AND WIRING UNDER THE OWNERSHIP OR RESPONSIBILITY OF THE SERVING ELECTRICAL UTILITY IS NOT REGULATED BY THE NEC. THE APPLICABLE SERVING UTILITY MUST BE CONTACTED FOR ANY ADDITIONAL REQUIREMENTS. 2.UNLESS OTHERWISE NOTED, CODE REFERENCES SHALL BE FROM THE 2005 NATIONAL ELECTRICAL CODE (NFPA 70 - NEC) AS AMENDED BY THE CURRENT CITY ADOPTED ORDINANCE. 3.THIS SHOULD NOT BE CONSIDERED AS A COMPLETE LIST OF CODE REQUIREMENTS. ELECTRICAL INSPECTIONS MUST BE PERFORMED AND ”APPROVED” BEFORE THE WORK IS CONSIDERED COMPLETED BY THE CITY OF SAN LUIS OBISPO. C.DEFINITIONS (NEC ARTICLE 100) 1.QUALIFIED PERSON – ONE FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE EQUIPMENT AND THE HAZARDS INVOLVED, I.E. LICENSED ELECTRICAL ENGINEER OR LICENSED ELECTRICAL CONTRACTOR. 2.SERVICE (ELECTRICAL) – THE CONDUCTORS AND EQUIPMENT FOR DELIVERING ELECTRIC ENERGY FROM THE SERVING UTILITY TO THE WIRING SYSTEM OF THE PREMISES SERVED. 3.SERVICE POINT – THE POINT OF CONNECTION BETWEEN THE FACILITIES OF THE SERVING UTILITY AND THE PREMISES WIRING. 4.SERVICE EQUIPMENT – ALSO REFERRED TO AS THE SERVICE ENTRANCE SECTION OR “SES”. THE NECESSARY EQUIPMENT USUALLY CONSISTING OF CIRCUIT BREAKERS OR SWITCHES AND FUSES CONNECTED TO THE LOAD END OF SERVICE CONDUCTORS TO A BUILDING OR OTHER STRUCTURE, OR AN OTHERWISE DESIGNATED AREA, AND INTENDED TO CONSTITUTE THE MAIN CONTROL AND CUTOFF SUPPLY. 5.SUBSERVICE – THE NECESSARY EQUIPMENT CONNECTED TO THE LOAD SIDE OF SERVICE EQUIPMENT 6.SUB-PANEL OR PANEL – A TRADE TERM FOR SUBSERVICE PANELBOARDS OR LOAD CENTERS. 7.PREMISES WIRING – ALL ON-SITE WIRING FROM THE SERVICE POINT TO THE END UTILIZATION OUTLET. 8.FEEDERS – ALL CIRCUIT CONDUCTORS BETWEEN THE SERVICE EQUIPMENT AND THE FINAL OVERCURRENT DEVICE (CIRCUIT BREAKER). D.LOCATION 1.ELECTRICAL UTILITY: WHILE IN THE PLANNING STAGE AND BEFORE PERFORMING ANY WORK, CONTACT THE SERVING ELECTRICAL UTILITY REGARDING THE LOCATION OF THE SERVICE POINT, INSTALLATION REQUIREMENTS, EQUIPMENT TYPE AND REQUIRED CLEARANCES. 2.CLEARANCES IN FRONT OF THE SES AND SUB-PANELS NEC 110.26: (a)A MINIMUM THREE (3) FOOT DEEP LEVEL SPACE IN FRONT OF THE EQUIPMENT. NEC 110.26(A)(1). (b)MINIMUM 2’-6” (30”) WIDE SPACE OR WIDTH OF EQUIPMENT, WHICHEVER IS GREATER. NEC 110.26(A)(2). (c)EQUIPMENT DOORS MUST BE ABLE TO FULLY OPEN 90 DEGREES. NEC 110.26(A)(2). (d)MINIMUM 6’-6” HIGH OR TOP OF THE EQUIPMENT, WHICHEVER IS HIGHER. NEC 110.26(A)(3), 110.26(E). (e)THE ACCESS AND WORK SPACE SHALL NOT BE USED FOR STORAGE. NEC 110.26(B). 3.OUTDOOR/WATER/MOISTURE – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO WATER OR MOISTURE ON A REGULAR BASIS OR IN LARGE QUANTITIES, I.E. WHERE EXPOSED TO LAWN SPRINKLERS OR BELOW A ROOF SCUPPER. NEC 110.26(F). 4.VEHICULAR TRAFFIC – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED WHERE SUBJECT TO DAMAGE BY VEHICULAR TRAFFIC. NEC 110.26(F). 5.CLOTHES CLOSETS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN CLOTHES CLOSETS. NEC 240.24(D). 6.BATHROOMS – SERVICE EQUIPMENT AND SUB-PANELS SHALL NOT BE LOCATED IN BATHROOMS. NEC 240.24(E). 7.SEPARATE BUILDINGS – REFER TO NEC 225.30 PART B, 250.32, 250.50, 250.104 FOR REQUIRED DISCONNECTING MEANS, GROUNDING, AND BONDING. E.PERMIT AND PLAN REQUIREMENTS 1.SITE (PLOT) PLAN: PROVIDE A SIMPLE SITE PLAN (MINIMUM SCALE 1:40) INDICATING THE LOCATION OF EXISTING BUILDING(S), STRUCTURES, FENCES, POOLS, SPAS, ETC, AND THE LOCATION OR AREA WHERE THE SERVICE AND PANELBOARDS ARE TO BE INSTALLED. REFER TO THE SITE PLAN INCLUDED. 2.SINGLE LINE (FEEDER) DIAGRAM NEC 215.5. – DIAGRAM(S) ARE INCLUDED FOR REVIEW. 3.LOAD CALCULATIONS NEC 220 – PROVIDE ELECTRICAL LOAD CALCULATIONS FOR THE ELECTRICAL SERVICE (SES) AND EACH SUB-SERVICE PANEL TO BE INSTALLED. THE STANDARD OR OPTIONAL METHOD MAY BE USED. A COMPLETED OPTIONAL METHOD IS ATTACHED. EXAMPLES OF BOTH METHODS ARE LOCATED IN APPENDIX D OF THE NEC. F.INSPECTION REQUIREMENTS THE INSPECTION CARD LISTS IN DETAIL THE REQUIRED INSPECTIONS. THE FOLLOWING INSPECTIONS ARE FOR YOUR INFORMATION AND MAY VARY DEPENDING UPON THE INSTALLATION. 1.ROUGH ELECTRICAL 2.FINAL ELECTRIC 3.TEMPORARY ELECTRIC IN PERMANENT POSITION IS AN OPTION THAT CAN ALSO BE USED. AN APPLICATION AND REFUNDABLE DEPOSIT ARE REQUIRED. 4.FOR SERVICE SHUT DOWNS, PLEASE CALL INSPECTION SERVICES TO ARRANGE AN INSPECTION. Electric Panel Requirements / Calculations Basis of Design - Plumbing Calculation EXISTING RESIDENCE. EXISTING WATER PRESSURE AT HOSE BIB CLOSEST TO WATER METER MEASURES 65 PSI. FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 1 1/2"2.5 2.5 LAV SINK 1 1/2"1.5 1.5 KITCHEN SINK 1 1/2"1.5 1.5 COMBINATION TUB / SHOWER 1 1/2"4.0 4.0 DISHWASHER 1 1/2"1.5 1.5 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 17.5 PROPOSED ADU FIXTURE TYPE QUANTITY MIN. PIPE SIZE WSFU/EA.TOTAL WSFU TOILET 2 1/2"2.5 5.0 LAV SINK 2 1/2"1.5 3.0 KITCHEN SINK 1 1/2"1.5 1.5 COMGO BATH/SHOWER 2 1/2"4.0 8.0 SHOWER 2 1/2"2.0 4.0 DISHWASHER 0 1/2"1.5 0.0 HOSE BIB 1 1/2"2.5 2.5 LAUNDRY 1 1/2"4.0 4.0 TOTAL 20.0 TOTAL (EXISTING RESIDENCE + ADU)37.5 PLUMBING CALCULATION NOTES: 1.THE EXISTING WATER METER IS A 3/4" SIZE WITH A 3/4" BUILDING SUPPLY LINE ON THE CUSTOMER SIDE OF THE METER. USING TABLE 610.3/610.4 FROM THE 2022 CA PLUMBING CODE TO DETERMINE PROPOSED AND EXISTING “WATER SUPPLY FIXTURE UNITS” (WSFU), THE COMBINATION OF EXISTING AND PROPOSED FIXTURE UNITS DOES NOT FALL WITHIN THE ACCEPTABLE RANGE, AND THEREFORE: 2.THE EXISTING 3/4" WATER METER WILL BE UPGRADED WITH A 1" WATER METER AND THE 3/4" BUILDING SUPPLY LINE SHALL BE UPGRADED WITH A 1" BUILDING SUPPLY LINE IN ORDER TO BE ADEQUATE FOR THE PROPOSED ADU. November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 MEP3 Exterior Lighting Compliance Exterior Light Specs N.T.S.C CAD file: cwa job no: drawn by: plot date: 20250 197 sheet: sheet data: revision: sheet title: rev description byissue date SUBMITTAL TO THE S.L.O. P/B DEPARTMENT NCproject:Attached Residential ADU619 A Grove St.San Luis Obispo, CA 93401applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, CA 93405CWA christopher william allen 1668 sydney street, slo, ca 93401 email: cwa.arch@gmail.com telephone: 805.286.5186 AIA, LEED AP, C-35818 CHRISTOPHER W. ALLEN C35818 EXP. 09.30.27LICENSED A RCHITE C TS TATE OF C A L I F O R N IA12/22/25 26.0319 legal stuff: The use of thes e plans and specificat ions shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the a rc hitect. Titl e to t hes e p la ns an d s pe cifi ca t io ns remains with cwa studios without prejudice. Visual contac t w ith th e se p lans and s pe ci f icati o ns s ha ll constitute prima face evidence of the acceptance of t hes e r est r i ct ion s. c 2 02 6 c w a s t u di o s SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC02/20/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/05/25 SUBMITTAL TO THE S.L.O. P/B DEPARTMENT EHC03/19/25 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 S0.1 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 S0.2 Structural General Notes CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 S1.1 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.2 Typical Details November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.3 Typical Details November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Typical Details CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S1.4 Typical Details November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these plans and specif ications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the ar chi t ec t. Ti t le t o these plans a nd speci f ications remains with cwa studios without prejudice. Visual con t ac t with t hes e plan s an d s peci f ic a t io ns shal l constitute prima face evidence of the acceptance of t h e s e re s t ri c t i o ns . c 20 20 c wa s t u di osproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.1 Foundation Plan November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.2 Second Floor Framing Plan November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S2.3 Roof Framing Plan November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 = "'-U') � 00a, '<I' "' "' -"' C: ;;.: C0 ·- '<I' Cl < "" C: u ;:;;­..,, • 0 1'--1 o e �-----,- C. I!! .!!! � .i � 00 Jj�---- '-' a, c:: ;;: 0 --'E C.C. "' Q) .lo:: N06J735 Q) > ·;::Cl ,-0""' M c) U") 0""' M C) VJ <'Cl E c..:i C) 0·a5 :I: VJ 0 :c C: 0� :::::s e en0 '- ·-a: Q) C: U) ...J ..c: M C: 0 I.D t'tl --, ,- U) revision: rllV dimipti111 PC CORREC'IDN legal stuff: :::, ..c u. ti 0 2 � 00 � WJ!ldate by 00.15.25 The use of these plans and specifications shall be rn.strlcted ta the use of the orlglrial site for wlllch they were prepared and publication thereof is expressly limtted to such use unless otherwise approved by the architect. Title to these plan3 and specifications remains with cwa studios without prejudice. Visual contact wllll these plans end apeclflcatlons shell constitute pr1ma face evidence of the acceptance of these restrictions c 2020 cwa studios sheet data: SWAjob no: CAD file:drawn by: plot dare: sheet title: 25053.01 JI/ 11.22.25 Structural Details sheet: S3.1 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 CAD file: SWA job no: drawn by: plot date: 25053.01 sheet: sheet data: revision: sheet title: rev description byissue date 11/18/16SUBMITTAL TO THE S.L.O. P / B DEPARTMENTS cwa JW 11.22.25 legal stuff: The use of these pl ans and specifications shall be restricted to the use of the original site for which they were prepared and publication thereof is expressly limited to such use unless otherwise approved by the arch ite ct. Title to t he se pl a ns and sp ec ific a ti o ns remains with cwa studios without prejudice. Visual co ntact wi t h th ese pl a ns a nd sp e cifi cation s sh a ll constitute prima face evidence of the acceptance of th e se r e st r ic ti on s . c 2 02 0 cw a st ud i o sproject:applicant / owner:John Rourke163 Serrano Heights DriveSan Luis Obispo, Ca 93405Residential Addition619 Grove St.San Luis Obispo, CA 934011 PC CORRECTION 08.15.25 S3.2 Structural Details November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Revised Dec. 2019 Design Professional’s stamp APPLICATION FOR WAIVER OF SOILS TEST FOR MINOR ADDITIONS TO ONE AND TWO-FAMILY DWELLING UNITS GENERAL INFORMATION: Project Address: ___________________________________Application #: _________________ Applicant Name: _____________________________________Phone #: ________________ BACKGROUND: Historically, quantifiable data has been created using accepted soil science methodologies by approved agencies using approved methods indicating that, in general, the soil conditions likely to be encountered throughout the City of San Luis Obispo would consist of expansive, compressible, shifting or other questionable soil characteristics. These types of soil conditions would require a complete geotechnical evaluation for moderate and major projects. PURPOSE: In order to help alleviate the burdens of time and disproportionately high cost associated with obtaining a soil test for minor residential additions up to 500 square feet to one and two family dwellings, the City of San Luis Obispo Building Division has developed a policy allowing a waiver of the soil test as specified in the California Residential Code Section R401.4. POLICY STATEMENT: Where a soils test has not been previously provided in accordance with the 2022 CRC Section R401.4; one and two family dwelling unit residential additions of 500 square feet or less, up to two stories (addition footprint area), may forego a soils test provided the applicant agrees to the following checked statements by signing and dating this application in the appropriate location at the bottom of this application: An on-site investigation has revealed no foundation failure of the existing residence. The type of construction proposed meets or exceeds the minimum provisions for wall and roof-ceiling construction in accordance with the 2022 CRC Chapters 6 and 8. The foundation system proposed meets or exceeds the minimum requirements in accordance with the 2019 City of San Luis Obispo Construction and Fire Code Amendments Table 1809.7. A minimum allowable soil bearing pressure of 1500 PSF has been utilized for the design of foundation systems as shown in the 2022 CRC Table R401.4.1. The proposed area of work on the site does not exceed a maximum 20% slope. Print Name:_____________________________________________________________ Licensed Architect or Engineer Signature: ____________________________________________Date: _____________ Office Use Only: Approval Signature: ___________________________________Date: ______________ 619 Grove Street, San Luis Obispo, CA 93405 Chris Allen 8052865186 Chris Allen 12/19/2025 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Calculations Job #: SWA 25053.01 Date: 12/01/25 Contents Load Tables 1 Roof & Floor Framing 2-6 Wall Stud / Post Design 7-20 Lateral Design 21-37 Foundation Design 38 Structural Calculations For RESIDENTAIL ADDITION 619 Grove St. San Luis Obispo, CA 93401 Client: CWA Studios Stair Calculations for Plan Check 39-45 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 Load Tables: Roof Framing Roof Comp Shingles =6.00 psf 5/8" plywood sheathing =1.90 psf 2x12 @ 16" o.c. =3.10 psf Insulation =0.50 psf Gyp Ceiling =3.00 psf Subtotal = 14.50 psf Slope correction for 2:12 =1.01 Subtotal =14.7 psf misc (sprinklers, overframing etc.) =3.30 psf Total Roof DL = 18.0 psf Roof Lr =20.00 psf Floor Framing Flooring =5.00 psf 3/4" Plywd. =2.30 psf 2−2x10 @ 16" o.c. =3.40 psf gyp ceiling / Plaster =3.00 psf Misc. =3.30 psf Total Floor DL = 17.00 psf Floor LL =40.00 psf Exterior Walls Stucco / Stone Veneer =10.00 psf Plywood sheathing =1.50 psf 2x6 wood studs @ 16" o.c. =1.50 psf Insulation =0.50 psf 5/8" gypboard =3.00 psf Misc. =1.50 psf Total Exterior Wall DL = 18.00 psf 2x6 wood studs @ 16" o.c. =1.50 psf Insulation =0.50 psf 5/8" gypboard [two sides] =6.00 psf Misc. =2.00 psf Total Interior Wall DL = 10.00 psf Interior Walls PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 1 2 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: ROOFDescription : Wood Beam Design :RR1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.669 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 9.500 inft 38.69 psi Fb : Allowable : 1,293.75 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.172 : 1 0.000 ft 864.95 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.275 in Transient Upward 0.000in Total Downward 0.523 in Total Upward 0.000 in 0.23 0.250.23 0.25 Ratio 828 435Ratio LC: Lr Only LC: +D+Lr LC:LC: Wood Beam Design :RR2 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 2.0 ft .Design Summary Max fb/Fb Ratio =0.070 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 2.500 inft 10.58 psi Fb : Allowable : 1,293.75 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.047 : 1 4.067 ft 90.07 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.002 in Transient Upward 0.000in Total Downward 0.004 in Total Upward 0.000 in 0.09 0.100.09 0.10 Ratio 9999 9999Ratio LC: Lr Only LC: +D+Lr LC:LC: 3 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Wood Beam Design :RB1 - RIDGE BEAM Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 (1) Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 (1) Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0180, Lr = 0.020 k/ft, Trib= 5.0 ft .Design Summary Max fb/Fb Ratio =0.494 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 6.000 inft 36.77 psi Fb : Allowable : 1,125.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+Lr 225.00 psi fb : Actual : Max fv/FvRatio =0.163 : 1 11.080 ft 555.89 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.071 in Transient Upward 0.000in Total Downward 0.134 in Total Upward 0.000 in 0.54 0.600.54 0.60 Ratio 2039 1073Ratio LC: Lr Only LC: +D+Lr LC:LC: 4 5 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: FLOORDescription : Wood Beam Design :FJ1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 BEAM Size :2x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-22 / IBC 2024 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.755 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 7.375 inft 43.40 psi Fb : Allowable : 1,035.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.241 : 1 13.816 ft 781.91 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.200 in Transient Upward 0.000in Total Downward 0.285 in Total Upward 0.000 in 0.17 0.390.17 0.39 Ratio 884 620Ratio LC: L Only LC: +D+L LC:LC: Wood Beam Design :FB1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-22 / IBC 2024 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.0170, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.032 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 2.250 inft 3.81 psi Fb : Allowable : 990.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.021 : 1 0.000 ft 31.19 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.001 in Transient Upward 0.000in Total Downward 0.001 in Total Upward 0.000 in 0.05 0.120.05 0.12 Ratio 9999 9999Ratio LC: L Only LC: +D+L LC:LC: 6 Wind Criteria ASCE 7−16 − Chapter 30 ASCE 7−16 Design Wind Loads [Component & Cladding]  Wind Design Force: P=qh (GCp -GCpi)(30.3−1) qh = 0.00256KzKztKdKeV2 26.10−1 Kz =0.66 (Exp. B) Sect 26.10.1 and Table 26.10−1 Kzt =1.00 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.00 mph Fig. 26.5−1B qz =12.4 psf (lrfd) At =10.0 ft2 min. GCp =1.0 (Zone 4 &5) Fig.30.3−1 GCp =−1.1 (Zone 4) Fig.30.3−1 GCp =−1.4 (Zone 5)Fig.30.3−1 GCpi =0.18 26.13 & Table 26.13−1 P= −15.90 psf (Zone 4) P= −19.63 psf (Zone 5) PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 7 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x4Analysis Method : 11.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0 psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 11.25 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 12.801 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 11.250 ft, D = 0.150 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.3541 Location of max.above base 5.587 ft Applied Axial 0.1628 k Applied Mx 0.1107 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 16.875 psi 180.0Allowable Shear psi 0.06250 : 1 Bending Compression Shear Location of max.above base 11.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.03938 k Bottom along Y-Y 0.03938 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.2974 in at 5.663 ft above base for load combination :+D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 305.488 psi Other Factors for load combination :n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 11.250 ft0.217 ft0.1021X Axis +D+L 1.000 PASS PASS5.587 0.06250 11.250 ft0.197 ft0.3541X Axis +D+0.750L 1.250 PASS PASS5.587 0.03750 11.250 ft0.159 ft0.2326X Axis +0.60D 1.600 PASS PASS0.0 0.0 11.250 ft0.125 ft0.05973X Axis . 8 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1 Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k)Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.163 +D+L -0.039 0.163-0.039 +D+0.750L -0.030 0.163-0.030 +0.60D 0.098 L Only -0.039-0.039 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.163 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.039 Ry, Top Max Ry, Top Min -0.039 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.297 5.663ftftinin 0.000 +D+0.750L 0.0000 0.223 5.663ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.297 5.663ftftinin 0.000 .Sketches 3.50 in1.50 in +Y +X 2x4 Load 1 Height = 11.250 ft0.150k Height = 11.250 ft0.150k 0.01klf 9 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C2 (Balloon framed stud @ Grid 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x6Analysis Method : 20.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 5.50 in Area 8.250 in^2 Ix 20.797 in^4 Iy 1.547 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 36.208 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 20.250 ft, D = 0.760 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.7719 Location of max.above base 10.057 ft Applied Axial 0.7962k Applied Mx 0.3588 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 19.330 psi 180.0Allowable Shear psi 0.07159 : 1 Bending Compression Shear Location of max.above base 20.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.07088 k Bottom along Y-Y 0.07088 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.8045 in at 10.193 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 367.110 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 20.250 ft0.272 ft0.2652X Axis +D+L 1.000 PASS PASS10.057 0.07159 20.250 ft0.247 ft0.7719X Axis +D+0.750L 1.250 PASS PASS10.057 0.04296 20.250 ft0.201 ft0.5556X Axis +0.60D 1.600 PASS PASS0.0 0.0 20.250 ft0.159 ft0.1536X Axis . 10 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C2 (Balloon framed stud @ Grid 0Y) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.796 +D+L -0.071 0.796-0.071 +D+0.750L -0.053 0.796-0.053 +0.60D 0.478 L Only -0.071-0.071 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.796 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.071 Ry, Top Max Ry, Top Min -0.071 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.804 10.193ftftinin 0.000 +D+0.750L 0.0000 0.603 10.193ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.804 10.193ftftinin 0.000 .Sketches 5.50 in1.50 in +Y +X 2x6 Load 1 Height = 20.250 ft0.760k Height = 20.250 ft0.760k 0.01klf 11 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 6x6Analysis Method : 20.25Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.1 Fb +1,200.0 1,200.0psi 1,000.0 625.0 170.0 825.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.0 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 5.50 in Exact Depth 5.50 in Area 30.250 in^2 Ix 76.255 in^4 Iy 76.255 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.0 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.0 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 132.764 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 20.250 ft, D = 0.760, E = 11.0 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.7696 Location of max.above base 0.0 ft Applied Axial 8.593k Applied Mx 0.0 k-ft Load Combination +D+0.70E Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 5.272 psi 170.0Allowable Shear psi 0.02067 : 1 Bending Compression Shear Location of max.above base 20.250 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.07088 k Bottom along Y-Y 0.07088 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp Only, fc/Fc' Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.2194 in at 10.193 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 369.087 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 20.250 ft0.386 ft0.08493X Axis +D+L 1.000 PASS PASS10.057 0.02067 20.250 ft0.353 ft0.1287X Axis +D+0.750L 1.250 PASS PASS0.1359 0.01240 20.250 ft0.289 ft0.08158X Axis +0.60D 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.04798X Axis +D+0.70E 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.7696X Axis +D+0.750L+0.5250E 1.600 PASS PASS0.1359 0.009691 20.250 ft0.231 ft0.5972X Axis +0.60D+0.70E 1.600 PASS PASS0.0 0.0 20.250 ft0.231 ft0.7376X Axis . 12 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.893 +D+L -0.071 0.893-0.071 +D+0.750L -0.053 0.893-0.053 +0.60D 0.536 +D+0.70E 8.593 +D+0.750L+0.5250E -0.053 6.668-0.053 +0.60D+0.70E 8.236 L Only -0.071-0.071 E Only 11.000 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 11.000 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.071 Ry, Top Max Ry, Top Min -0.071 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.219 10.193ftftinin 0.000 +D+0.750L 0.0000 0.165 10.193ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 +D+0.70E 0.0000 0.000 0.000ftftinin 0.000 +D+0.750L+0.5250E 0.0000 0.165 10.193ftftinin 0.000 +0.60D+0.70E 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.219 10.193ftftinin 0.000 E Only 0.0000 0.000 0.000ftftinin 0.000 . 13 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C3 (SW Post @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 5.50 in5.50 in +Y +X 6x6 Load 1 Height = 20.250 ft11.760k Height = 20.250 ft11.760k 0.01klf 14 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x4Analysis Method : 8Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.50 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 3.50 in Area 5.250 in^2 Ix 5.359 in^4 Iy 0.9844 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.150 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.50 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 8 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 9.103 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 8.0 ft, D = 0.80, Lr = 0.060, L = 0.440 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.4305 Location of max.above base 3.973 ft Applied Axial 1.249k Applied Mx 0.0560 k-ft Load Combination +D+L Load Combination +D+L Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 12.0 psi 180.0Allowable Shear psi 0.04444 : 1 Bending Compression Shear Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.0280 k Bottom along Y-Y 0.0280 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-4 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 0.07605 in at 4.027 ft above base for load combination : +D+L Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 568.13 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 8.0 ft0.400 ft0.2756X Axis +D+L 1.000 PASS PASS3.973 0.04444 0.0 ft0.366 ft0.4305X Axis +D+Lr 1.250 PASS PASS0.0 0.0 8.0 ft0.301 ft0.2837X Axis +D+0.750Lr+0.750L 1.250 PASS PASS3.973 0.02667 0.0 ft0.301 ft0.3931X Axis +D+0.750L 1.150 PASS PASS3.973 0.02899 0.0 ft0.324 ft0.3818X Axis +0.60D 1.600 PASS PASS0.0 0.0 8.0 ft0.240 ft0.1551X Axis . 15 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.809 +D+L -0.028 1.249-0.028 +D+Lr 0.869 +D+0.750Lr+0.750L -0.021 1.184-0.021 +D+0.750L -0.021 1.139-0.021 +0.60D 0.485 Lr Only 0.060 L Only -0.028 0.440-0.028 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 1.249 Axial, Base Min 0.060 Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.028 Ry, Top Max Ry, Top Min -0.028 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.076 4.027ftftinin 0.000 +D+Lr 0.0000 0.000 0.000ftftinin 0.000 +D+0.750Lr+0.750L 0.0000 0.057 4.027ftftinin 0.000 +D+0.750L 0.0000 0.057 4.027ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 Lr Only 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.076 4.027ftftinin 0.000 . 16 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C4 (First Floor Stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 3.50 in1.50 in +Y +X 2x4 Load 1 Height = 8.0 ft1.30k Height = 8.0 ft1.30k 0.01klf 17 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: . Referenced Design Standard(s) : NDS 2018 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2021 General Information Wood Section Name 2x6Analysis Method : 19.5Overall Column Height ft Allowable Stress Design ( Used for non-slender calculations )Allow Stress Modification Factors End Fixities Top & Bottom Pinned Wood Species Douglas Fir-Larch Wood Grade No.2 Fb +900.0 900.0psi 1,350.0 625.0 180.0 575.0 31.210 psi Fv psi Fb -Ft psi Fc - Prll psi psi Density pcf Fc - Perp E : Modulus of Elasticity . . . 1,600.0 580.0 1,600.0 580.0 Cfu : Flat Use Factor 1.0 Cf or Cv for Tension 1.30 Use Cr : Repetitive ? Kf about Y 1.0 Exact Width 1.50 in Exact Depth 5.50 in Area 8.250 in^2 Ix 20.797 in^4 Iy 1.547 in^4 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Ct : Temperature Factor 1.0 Cf or Cv for Compression 1.10 1,600.0 Axial Cm : Wet Use Factor 1.0 Cf or Cv for Bending 1.30 x-x Bending y-y Bending ksi YesMinimum Basic Fully braced against buckling ABOUT Y-Y Axis ABOUT X-X Axis: Lux = 16.0 ft, Kx = 1.0 Column Buckling Condition: Kf about X 1.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Column self weight included : 34.867 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 19.50 ft, D = 0.410, Lr = 0.060 k BENDING LOADS . . . Lat. Uniform Load creating Mx-x, L = 0.0070, W = 0.0160 k/ft .DESIGN SUMMARY PASS PASS Max. Axial+Bending Stress Ratio =0.9240 Location of max.above base 9.685 ft Applied Axial 0.4899k Applied Mx 0.5917 k-ft Load Combination +D+0.750Lr+0.750L+0.450W Load Combination +D+0.750Lr+0.750L+0.450W Bending & Shear Check Results Maximum Shear Stress Ratio = Applied Design Shear 33.106 psi 288.0Allowable Shear psi 0.07663 : 1 Bending Compression Shear Location of max.above base 0.0 ft : 1 At maximum location values are . . . Applied My 0.0 k-ft Maximum SERVICE Lateral Load Reactions . . Top along Y-Y 0.1560 k Bottom along Y-Y 0.1560 k Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Maximum SERVICE Load Lateral Deflections . . . Along Y-Y 1.581 in at 9.815 ft above base for load combination : W Only Along X-X 0.0 in at 0.0 ft above base Fc : Allowable 377.001 psi Other Factors for load combination : n/a . Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About D Only 0.900 PASS PASS0.0 0.0 19.50 ft0.272 ft0.1482X Axis +D+L 1.000 PASS PASS9.685 0.06894 0.0 ft0.247 ft0.5910X Axis +D+Lr 1.250 PASS PASS0.0 0.0 19.50 ft0.201 ft0.1643X Axis +D+0.750Lr+0.750L 1.250 PASS PASS9.815 0.04136 0.0 ft0.201 ft0.4277X Axis +D+0.750L 1.150 PASS PASS9.815 0.04496 0.0 ft0.217 ft0.4261X Axis +D+0.60W 1.600 PASS PASS9.685 0.05909 0.0 ft0.159 ft0.7026X Axis +D+0.750Lr+0.750L+0.450W1.600 PASS PASS9.685 0.07663 0.0 ft0.159 ft0.9240X Axis 18 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Axial + Bending Stress Ratios Maximum Shear RatiosControlling Cp DCLoad Combination Stress Ratio Location Stress Ratio Status LocationValueStatus Load Combination Results About +D+0.750L+0.450W 1.600 PASS PASS9.685 0.07663 0.0 ft0.159 ft0.9051X Axis +0.60D+0.60W 1.600 PASS PASS9.685 0.05909 0.0 ft0.159 ft0.6485X Axis +0.60D 1.600 PASS PASS0.0 0.0 19.50 ft0.159 ft0.08582X Axis .Note: Only non-zero reactions are listed. Load Combination Rx (k)Ry (k) Axial (k) @ Base @ Top @ Base@ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top My (k-ft)Mx (k-ft) D Only 0.445 +D+L -0.068 0.445-0.068 +D+Lr 0.505 +D+0.750Lr+0.750L -0.051 0.490-0.051 +D+0.750L -0.051 0.445-0.051 +D+0.60W -0.094 0.445-0.094 +D+0.750Lr+0.750L+0.450W -0.121 0.490-0.121 +D+0.750L+0.450W -0.121 0.445-0.121 +0.60D+0.60W -0.094 0.267-0.094 +0.60D 0.267 Lr Only 0.060 L Only -0.068-0.068 W Only -0.156-0.156 Item Rx (k)Ry (k)Axial (k) @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx (k-ft)My (k-ft) Axial, Base Max 0.505 Axial, Base Min Rx, Base Max Rx, Base Min Rx, Top Max Rx, Top Min Ry, Base Max Ry, Base Min -0.156 Ry, Top Max Ry, Top Min -0.156 .Maximum Deflections for Load Combinations Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance D Only 0.0000 0.000 0.000ftftinin 0.000 +D+L 0.0000 0.692 9.815ftftinin 0.000 +D+Lr 0.0000 0.000 0.000ftftinin 0.000 +D+0.750Lr+0.750L 0.0000 0.519 9.815ftftinin 0.000 +D+0.750L 0.0000 0.519 9.815ftftinin 0.000 +D+0.60W 0.0000 0.949 9.815ftftinin 0.000 +D+0.750Lr+0.750L+0.450W 0.0000 1.230 9.815ftftinin 0.000 +D+0.750L+0.450W 0.0000 1.230 9.815ftftinin 0.000 +0.60D+0.60W 0.0000 0.949 9.815ftftinin 0.000 +0.60D 0.0000 0.000 0.000ftftinin 0.000 Lr Only 0.0000 0.000 0.000ftftinin 0.000 L Only 0.0000 0.692 9.815ftftinin 0.000 W Only 0.0000 1.581 9.815ftftinin 0.000 . 19 Wood Column LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2025 DESCRIPTION:C5 (Balloon framed stud @ Grid 22X) Project File: Gravity.ec6 Project Title: Engineer: Project ID: Project Descr: Sketches 5.50 in1.50 in +Y +X 2x6 Load 1 Height = 19.50 ft0.470k Height = 19.50 ft0.470k 0.02klf 20 21 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 E−W L/B =0.56 Cp =0.8 (Windward) Fig.27.3−1 Cp =0.0 N/A (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =0.0 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =1.26 Cp =−1.30 (Windward)Fig.27.3−1 Cp =0.00 (Leeward)Fig.27.3−1 qGCp -qiGCi =−15.96 (Windward) qGCp -qiGCi =0.00 Mono slope (Leeward) qh GCp(x component) =−2.50 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 34 13.5 459 4,903 34 13.5 459 0 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 36 3 108 −270 36 3 108 0 Ptotal =4,634 lbs (lrfd) =2,780 lbs (asd) < Seismic = 6,423 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 23 Wind Criteria ASCE 7−16 − Chapter 27 ASCE 7−16 Design Building Wind Loads  Wind Design Force: P=qGCp -qiGCi (27.3−1) qh = 0.00256KzKztKdV2 26.10−1 Kz =0.66 Sect 26.10.1 and Table 26.10−1 Kzt =1.0 26.8.2 Kd =0.85 Sect 26.6 and Table 26.6−1 Ke =1.00 Sect 26.9 V =93.0 mph Fig. 26.5−1B qz =12.4 psf (lrfd) G =0.85 26.11.1 N−S L/B =1.79 Cp =0.8 (Windward) Fig.27.3−1 Cp =−0.342 (Leeward) Fig.27.3−1 GCpi =0.18 26.13 & Table 26.13−1 qGCp -qiGCi =10.7 psf (Windward) qGCp -qiGCi =−5.8 psf (Leeward) Roof θ Angle =9.0 (2:12) h/L =0.84 Cp =0.00 N/A (Windward)Fig.27.3−1 Cp =0.00 N/A (Leeward)Fig.27.3−1 qGCp -qiGCi =0.00 (Windward) qGCp -qiGCi =0.00 (Leeward) qh GCp(x component) =0.00 psf (Windward) qh GCp(x component) =0.00 psf (Leeward) (−) idicates wind direction away from roof Wall Wind Loads Windward Leeward B Htrib.A (ft2)P (lbs) B Htrib.A (ft2)P (lbs) 19 15 285 3,044 19 15 285 −1,666 Roof Wind Loads Windward Leeward BHA (ft2)P (lbs)B H A (ft2)P (lbs) 23 3 69 0 23 3 69 0 Ptotal =4,711 lbs (lrfd) =2,826 lbs (asd) < Seismic = 6,423 lbs Wall Roof Proof + Pfloor = PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 24 2022 CBC Seismic Criteria (based on the requirements of ASCE 7−16) 2022 CBC Section 1613 Earthquake Loads  Site Parameters: Site Class:DDefault Latitude =35.291 deg N Google Earth Longitude =120.657 deg W Google Earth Seismic Design Category:D USGS Design Maps SS =1.074 g USGS Design Maps Fa =1.20 Section 11.4.4 SMS =Fa SS =1.289 g (16−20) SDS =2/3 x SMS =0.859 g (16−22) SDS,MAX =2/3 x SMS,MAX =N/A g Calcs Pg. , Based on Section 12.8.1.3 S1 =0.396 g USGS Design Maps Fv =1.904 Table 1613.2.3(2) SM1 =Fv S1 =0.754 g (16−21) SD1 =2/3 x SM1 =0.503 g (16−23) ASCE 7−16 Section 12.8 Equivalent Lateral Force Procedure  Structural Parameters: hn =19.0 ft Ct =0.020 Table 12.8−2 x =0.75 " Ta =Ct(hn)x =0.18 sec (12.8−7) TL =8 sec > Ta Figure 22−14 R =6.50 Table 12.2−1 Ie =1.00 Table 1.5−2  Seismic Coefficient: Cs =SDS / (R/Ie)(12.8−2) =0.13 Cs,max =SD1 / [T x (R/Ie)]for T < TL (12.8−3) =0.42 Cs,min =0.044SDSIe > 0.01 (12.8−5) 0.04 Cs,min =0.5S1 / (R/Ie)for S1 > 0.6g (12.8−6) =0.03 light framed construction with plywd shear panels PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 25 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES  Seismic Base Shear: V =Cs W (12.8−1) =0.13 W =0.17 W =0.09 W =0.120 W Strength Level with Rho = 1.3 ASD Level ASD Level with Rho = 1.3 Strength Level ASCE 7−16 Section 12.8 26 Seismic Weights − 2−Story Portion (52X−74X) Second Floor Framing Height 8 ft +/− Roof Level Framing Height 17 ft +/− Roof Level Roof. . . w =18 psf A =725 sf W =13,050 lb Exterior Walls. . . w =18 psf L =68 ft htrib =5.0 ft W =6,120 lb Interior Walls. . . w =10 psf L =48 ft htrib =5.0 ft W =2,400 lb Total Sesimic Weight at Roof 21,570 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 27 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES Floor Level Typical Floor . . . w =17 psf A =538 sf W =9,146 lb Exterior Walls. . . walls above = 6120 lb w =18 psf L =68 ft htrib =10.0 ft W =18,360 lb Interior Walls. . . walls above = 2400 lb w =10 psf L =48.0 ft htrib =4.0 ft W =4,320 lb Total Sesimic Weight at Floor 31,826 lb Vertical Distribution Two Story Portion ~ ASD Level, Rho = 1.3 Level Seismic W V Height VxH % V Per SF Roof 21,570 2595 17 44108.4 59.0 3791 5.2 2nd floor 31,826 3828 8 30626.3 41.0 2632 4.9 6423 74735 6423 Total Base Shear V =7058 lb V =6423 lb LRFD ASD Level with Rho = 1.3 28 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES E−W Line Loads Roof Floor Line 0X. . .Line 0X. . . A trib. =265 ft2 A trib. =209 ft2 V dia. =1,383 lb V dia. =1,023 lb V in plane SW =391 lb V in plane SW =329 lb V roof =1,774 lb V total =1,774 lb V total =3,125 lb Line 22X. . .Line 22X. . . A trib. =363 ft2 A trib. =269 ft2 V dia. =1,895 lb V dia. =1,316 lb V in plane SW =195 lb V in plane SW =175 lb V roof =2,090 lb V total =2,090 lb V total =3,582 lb Line 34X. . .Line 34X. . . A trib. =98 ft2 A trib. =60 ft2 V dia. =512 lb V dia. =294 lb V in plane SW =195 lb V in plane SW =173 lb V roof =707 lb V total =707 lb V total =1,174 lb A total =725 ft2 A total =538 ft2 N−S Line Loads Roof Floor Line 0Y. . .Line 0Y. . . A trib. =265 ft2 A trib. =209 ft2 V dia. =1,383 lb V dia. =1,023 lb V in plane SW =524 lb V in plane SW =381 lb V roof =1,907 lb V total =1,907 lb V total =3,311 lb Line 9Y. . .Line 9Y. . . A trib. =98 ft2 A trib. =60 ft2 V dia. =512 lb V dia. =294 lb V in plane SW =247 lb V in plane SW =208 lb V roof =759 lb V total =759 lb V total =1,261 lb Line 19Y. . .Line 19Y. . . A trib. =363 ft2 A trib. =269 ft2 V dia. =1,895 lb V dia. =1,316 lb V in plane SW =589 lb V in plane SW =589 lb V roof =2,484 lb V total =2,484 lb V total =4,389 lb A total =725 ft2 A total =538 ft2 29 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)ωdl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0X 1,774 S 11.00 10.0 161 1 19.00 17,738 192 16,630 60 MST60 22X SEE 1ST FLOOR SW 34X 707 S 10.00 10.0 71 1 10.00 7,073 234 5,613 154 MST60 0X 3,125 S 5.50 8.0 568 4 2.75 12,502 263 477 5,404 HDUE7 H/W ratio penalized S8.05684 2.75 12,502 263 477 5,404 HDUE7 H/W ratio penalized 22X 3,582 S 9.00 19.3 398 2 9.00 68,948 401 7,781 7,196 HDUE9−4x H/W ratio penalized 34X 1,174 S 10.00 8.0 117 1 10.00 9,392 246 5,900 521 HDUE3 Project: ______________________________________________________ V (lbs) E−W 2nd FLOOR E−W 1st FLOOR 30 Job#:_________________ Date:_____________ Page:____________ SHEAR WALL ANALYSIS: Grid LTOT (ft) Ht (ft)v (plf) USE LWALL (ft)MOT (#ft)ωdl (plf) Mr (#ft)T/C (lbs) Strap/ Holdown Comments 0Y 1,907 S 22.00 11.0 87 1 22.00 20,977 405 47,017 N/A MST60 9Y 759 S 12.00 9.5 63 1 12.00 7,213 252 8,704 N/A MST60 19Y 2,484 S 22.00 8.0 113 1 34.00 19,875 288 79,855 N/A MST60 0Y 3,311 S 22.00 8.0 150 1 22.00 26,484 155 18,039 393 HDUE3 15Y 1,261 S 12.00 8.0 105 1 12.00 10,085 155 5,367 410 HDUE3 19Y 4,389 S 27.00 9.0 163 1 34.00 39,504 173 48,076 N/A #N/A Project: ______________________________________________________ V (lbs) N−S 2nd FLOOR N−S 1st FLOOR 31 SHEAR WALL SCHEDULE ALLOWABLE VALUESShear WallSubfloor Connection (2 story or more)Concrete ConnectionPlywood 1/Nailing (10d's)VallSill Size FastenerVallSill Size FastenerVallSDS @ 8" o.c. 456 SW1one side 6" o.c. 339 SW1 2x 16d's @ 6" o.c. 374 SW1 2x 5/8" AB @ 4'-0" o.c. 372 SW1one side 4" o.c. 510 SW2 3x SDS @ 6" o.c.608 SW23x 5/8" AB @ 2'-8" o.c. 707 SW2one side 3" o.c.664 SW33x SDS @ 4" o.c. 912 SW3 3x 5/8" AB @ 2'-8" o.c. 707 SW3one side 2" o.c.869 SW43x SDS @3" o.c. 1216 SW4 3x 5/8" AB @ 1'-4" o.c. 1415 SW4Top Pl. Shear Clip ConnectionVallA35 @ 24" o.c.325 SW1A35 @ 12" o.c. 650 SW2A35 @ 8" o.c. 975 SW3A35 @ 6" o.c. 1300 SW4Shear Wall CapacityNOTES:Vall6" o.c.325SW11. Shear wall allowables based on NDS Table 4.3A4" o.c.510SW23" o.c.664SW32. Subfloor nailed connection allowables based on NDS Table 11N2" o.c.869SW4 2x sill, 16d's - Z = 1.6x118=188# ea.3. Subfloor SDS connection is Simpson SDS 1/4" dia.x 6" screws w/allowables per SimpsonSDS 1/4"x6"=190# x 1.6 = 304# ea.Holdowns4. Subfloor lag screw allowables based on NDS Table 11.5 for 3x sillMin.1/2" dia x 8" = 1.6x390=620# ea.Type Uplift Cap. ChordHDUE3 37902-2x5. Concrete connection allowables based on NDS Table 11EHDUE5 53752-2x2x sill, 5/8" dia. Bolts - Z = 1.6x930=1488# ea.HDUE766752-2x3x sill, 5/8" dia. Bolts - Z = 1.6x1180=1888# ea.HDUE9 84254x43x sill, 3/4" dia. Bolts - Z = 1.66x1540=2464# ea.6. Top Pl. shear clip connection is Simpson A35 w/allowables per SimpsonA35=650# ea.7. Holdown allowables per Simpson current catalog32 E-W Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 19.0 1.16 ok VDIA. - LINE 22X =1,895 lbs vdia. = 1,895 lbs /19.0 ft = 99.8 plf →214.3 plf D/C =0.5 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 22 10.0 2.20 ok VDIA. - LINE 22X =1,316 lb vdia. = 1,316 lbs /10.0 ft = 131.6 plf →214.3 plf D/C =0.6 (NDS Table 4.2C) N-S Roof… Dia. Ratio: L (ft) D (ft)Ratio < 4 19 22.0 0.86 ok VDIA. - LINE 19Y =1,895 lbs vdia. = 1,895 lbs /22.0 ft = 86.2 plf →214.3 plf D/C =0.4 (NDS Table 4.2C) Floor… Dia. Ratio: L (ft) D (ft)Ratio < 4 19 14.5 1.31 ok VDIA. - LINE 19Y =1,316 lb vdia. = 1,316 lbs /14.5 ft = 90.8 plf →214.3 plf D/C =0.4 (NDS Table 4.2C) 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 5/8" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. 3/4" str. 1 - unblocked dia. w/ 10d @ 6 " o.c. E.N. PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 33 Dia. chord design: line Vdia.(ASD)q = Vdia./L L D chord force Connector Connection Cap. D/C lb plf ft ft lbs MIN.lbs 0Y/19Y Roof 3,791 172 22 19 549 12−16d 2,447 0.22 0Y/19Y Floor 2,632 120 22 10 724 12−16d 2,447 0.30 Chord Force =qL2/D top pl. splice 12−16d 2,447 lb PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 34 Collector Analysis (ASCE 12.10.2) Roof… Line 22X 1.25V = 2,369 lbs Ltotal =19.0 ft Lshearwall =9.0 ft v1 = V / L total =124.70 plf v2 = V / Lshearwall =263.25 plf v1 -v2 =-138.55 plf SW Distance Length (ft) 9.0 10.0 unit shear (plf -138.55 124.70 Drag load(lbs)0 -1247 0 Max. Drag Load =1247 lb (See above) 12 - 16d 2447 lb (calc. pg. ) D/C =0.51 Simp. CS16 1705 lb (Simp. Catalog ) D/C =0.73 PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 35 Floor… Line 22X 1.25V = 1,645 lbs Ltotal =19.0 ft Lshearwall =9.0 ft v1 = V / L total =86.58 plf v2 = V / Lshearwall =182.79 plf v1 -v2 =-96.20 plf SW Distance Length (ft) 9.0 10.0 unit shear (plf -96.20 86.58 Drag load(lbs)0 -866 0 Max. Drag Load =866 lb (See above) 12 - 16d 2447 lb (calc. pg. )D/C =0.35 Simp. CS16 1705 lb (Simp. Catalog ) D/C =0.51 36 Nail Connection Structural Element: Nail : Species: Adjustment Factors: CM =1.00 CΔ =1.00 CD =1.60 Ct =1.00 Ceg =1.00 Cg =0.98 Cdi =1.00 Ctn =1.00 Z =131 lb (10 dia. min. pentration reduction included) m(1-m 2n)1+REA 1-m n =12 nails D =0.162 in s =1.5 in Es =1,600,000 psi Em =1,600,000 psi NDS Table 4A As =8.25 in2 Am =8.25 in2 EsAs EmAm EmAm EsAs γ = (180,000)(D 1.5)=11,737 lb/in u =1+γs/2 x (1/EmAm+1/EsAs)=1.00 m =u-(u2-1)1/2 =0.95 =0.98 Shear Plate Adjusted Design Value: Z’ =Z x CDCMCtCgCΔCegCdiCtn NDS Table 10.3.1 = 204 lb/ea. Z’ (12−16d) =2,447 lb Top plates splice 12 − 16d DF No. 2 Cg = NDS (10.3−1)n[(1+REAmn)(1+m)-1+m2n] REA =lessor of or =1.0 x PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 37 Foundation Design Allowable soil bearing pressure =1500 psf (CBC Table 1806.2) Footing Width W =15 in Footing Depth D=21 in Gridline 0Y /19Y (D+0.75Lr+0.75L) Roof DL =207 plf 207 plf Roof Lr =230 plf 173 plf Floor DL =11 plf 11 plf Floor LL =27 plf 20 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =835 plf 771 plf Soil bearing = 668 psf (Ptotal / W) <1500 psf Gridline 0X/34X (D+0.75Lr+0.75L) Roof DL =54 plf 54 plf Roof Lr =60 plf 45 plf Floor DL =106 plf 106 plf Floor LL =250 plf 188 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =830 plf 753 plf Soil bearing = 664 psf (Ptotal / W) <1500 psf Gridline 22X (D+0.75Lr+0.75L) Roof DL =54 plf 54 plf Roof Lr =60 plf 45 plf Floor DL =187 plf 187 plf Floor LL =440 plf 330 plf 20 ft ht. 2x wall =360 plf 360 plf Ptotal =1,101 plf 976 plf Soil bearing = 881 psf (Ptotal / W) <1500 psf PROJECT SHEET NO. CALC. BY DATE STORK WOLFE & ASSOCIATES 38 39 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: STAIRSDescription : Wood Beam Design :SJ Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x8, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.330 ft .Design Summary Max fb/Fb Ratio =0.055 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 1.500 inft 8.26 psi Fb : Allowable : 1,242.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.046 : 1 2.400 ft 68.32 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.001 in Transient Upward 0.000in Total Downward 0.002 in Total Upward 0.000 in 0.02 0.080.02 0.08 Ratio 9999 9999Ratio LC: L Only LC: +D+L LC:LC: Wood Beam Design :SS (Int. Stair Stringer governs) Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :2x6, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.50 ft .Design Summary Max fb/Fb Ratio =0.208 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 2.000 inft 21.59 psi Fb : Allowable : 1,170.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.120 : 1 0.000 ft 243.69 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.010 in Transient Upward 0.000in Total Downward 0.013 in Total Upward 0.000 in 0.03 0.120.03 0.12 Ratio 4597 3591Ratio LC: L Only LC: +D+L LC:LC: 40 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: Wood Beam Design :SB1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x12, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.0 ft 1Point: D = 0.0150, L = 0.060 k @ 0.0 ft 2Point: D = 0.030, L = 0.120 k @ 1.50 ft 3Point: D = 0.0150, L = 0.060 k @ 3.0 ft .Design Summary Max fb/Fb Ratio =0.015 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 2.000 inft 3.00 psi Fb : Allowable : 1,100.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.017 : 1 2.000 ft 16.95 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.000 in Transient Upward 0.000in Total Downward 0.000 in Total Upward 0.000 in 0.03 0.090.09 0.27 Ratio 9999 9999Ratio LC:LC: +D+L LC:LC: Wood Beam Design :SB2 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x8, Sawn, Fully Braced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.040 k/ft, Trib= 1.50 ft 1Point: D = 0.060, L = 0.20 k @ 0.0 ft 2Point: D = 0.120, L = 0.40 k @ 1.50 ft 3Point: D = 0.060, L = 0.20 k @ 3.0 ft .Design Summary Max fb/Fb Ratio =0.145 : 1 Max Reactions (k)HEWSLLr +D+LLoad Comb : Span # 1 Left Support D in 1.500 inft 19.65 psi Fb : Allowable : 1,300.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : +D+L 180.00 psi fb : Actual : Max fv/FvRatio =0.109 : 1 2.400 ft 188.08 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max Deflections Transient Downward 0.003 in Transient Upward 0.000in Total Downward 0.003 in Total Upward 0.000 in 0.15 0.490.15 0.49 Ratio 9999 9999Ratio LC: L Only LC: +D+L LC:LC: 41 Multiple Simple Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: Wood Beam Design :C1 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x4, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads 1Point: L = -0.20 k @ 9.167 ft .Design Summary Max fb/Fb Ratio =0.709 : 1 Max Reactions (k)HEWSLLr L OnlyLoad Comb : Span # 1 Left Support D in 6.000 inft 24.49 psi Fb : Allowable : 1,500.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : L Only 180.00 psi fb : Actual : Max fv/FvRatio =0.136 : 1 6.000 ft 1,063.67 psi at atfv : Actual : Ratio 0 Ratio 152 Max Deflections Transient Downward 0.000 in Transient Upward 0.000in Total Downward 0.120 in Total Upward -0.498 in 0.11-0.31 Ratio 9999 601Ratio LC:LC: L Only LC:LC: L Only <0 Wood Beam Design :C2 Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 BEAM Size :4x4, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Eminbend - xx ksi Wood Species :Wood Grade : Fb - Tension psi psi Fv psi Fb - Compr Ft psi Fc - Prll psi psiFc - Perp Ebend- xx ksi Density pcf Applied Loads 1Point: L = -0.20 k @ 6.167 ft .Design Summary Max fb/Fb Ratio =0.709 : 1 Max Reactions (k)HEWSLLr L OnlyLoad Comb : Span # 1 Left Support D in 3.000 inft 25.85 psi Fb : Allowable : 1,500.00 psi Right Support Fv : Allowable :Span # 1 Load Comb : L Only 180.00 psi fb : Actual : Max fv/FvRatio =0.144 : 1 0.000 ft 1,063.67 psi at atfv : Actual : Ratio 0 Ratio 226 Max Deflections Transient Downward 0.000 in Transient Upward 0.000in Total Downward 0.030 in Total Upward -0.335 in 0.21-0.41 Ratio 9999 1203Ratio LC:LC: L Only LC:LC: L Only <0 42 (Guardrail Post) Simp. DTT2Z w/ 1/2" dia. x 3" embed. lag screw (lag screw governs) Allow. Tension = 1 11/16" thr'd length x 378 #/in = 638# > 310# Simp. DTT2Z w/ 1/2" dia. x 3" embed. lag screw (lag screw governs) Allow. Tension = 1 11/16" thr'd length x 378 #/in = 638# > 410# (Guardrail Post) Wood Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 DESCRIPTION:C3 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: Referenced Design Standard(s) : NDS 2018 Load Combination Set : ASCE 7-16 Code References Governing Code : IBC 2021 Material Properties Beam Bracing :Completely Unbraced Allowable Stress Design Douglas Fir-Larch No.1 1,000.0 1,000.0 1,500.0 625.0 1,700.0 620.0 180.0 675.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 4x4 Span = 3.167 ft 1 2 L(0.2) .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Point Load : L = 0.20 k @ 3.167 ft .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio Maximum Shear Stress Ratio 4x4 0.136 Section used for this span4x4 : 10.709 =: 1 Load Combination L Only L Only Span # where maximum occurs Span # 1 Location of maximum on span 0.000ft 24.49 psi= 1,500.00psi Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination = = = 180.00 psi== 0.000 ft= = 1,063.67psi Maximum Deflection 0 >=120 442 Ratio =0 >=120 Max Downward Transient Deflection 0 in 0 Ratio = >=120 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.172 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v n/a n/a Span: 1 : L Only n/a NDS2024 NDS2024 .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 0.0 0.00 0.00.0 1.00Length = 3.167 ft 1 0.90 1.500 1.001.00 1.00 1,350.0 0.00 162.01.00 0.01.00 1.00L Only 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.167 ft 1 0.709 0.136 1.00 1.500 1.001.00 1.00 0.63 1,063.7 1,500.0 0.20 180.01.00 24.51.00 1.00+0.750L 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.167 ft 1 0.425 0.082 1.25 1.500 1.001.00 1.00 0.48 797.8 1,875.0 0.15 225.01.00 18.41.00 . 43 Wood Beam LIC# : KW-06016119, Build:20.25.10.02 STORK, WOLFE & ASSOCIATES (c) ENERCALC, LLC 1982-2026 DESCRIPTION:C3 Project File: STAIRS 2.19.26.ec6 Project Title: Engineer: Project ID: Project Descr: LocationLoad CombinationMax. LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl L Only1 0.1717 3.167 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.200 Max Upward from Load Combinations 0.150 Max Upward from Load Cases 0.200 L Only 0.200 +0.750L 0.150 44 Stork, Wolfe, & Associates lEngineers A 7ropcl,, Job +: LE 0 6z,D |al,e'? aqe c"b b,s ?o oS,. AS'u r ?r 6 c g lb r** T ir''e 4'%4b T^tt itr*? *" I ii_j :* t-t-l-ri H-1ffl f"rffi ;-i_l -l--t-.]- 1- 1,-'+r|]+ Il_ITil__F H-.J'-H +-+-r-+--i l_j___L ti- 1- I r'* 1- -1 lt I _l_ t_il i-i II H- I:I i t 1- 1'--:--- -#---1--1- t-.i i_.1 I i LJ rrtt-fr 1-l+.-t I { f' I t- I-f il;--.i -i+ I I -*--r- i-i-ffiL[il_ -t- J il _ L_* -1 I 1-t- +- 1-1- _I_I_] H j-]-:=tr ltr Lt I' .-1._ I i I I i I 45 4x4 Stormwater Control Plan for Post Construction Requirements Exhibit 4 Application Submittal Where directions state “Done” that means no additional information or forms below that point needs to be filled out or furnished. See Exhibits for Watershed Management Zones, Basins, & Urban Sustainability Areas Use “n/a” where information requested is not applicable. If you are unsure regarding how to fill out any of the information, please come in and request assistance from a staff person. Project Information Step 1 Applicant Name: Application No: Project Name: Location Address: Location APN: Site Zoning: Project Type:  Commercial Detached Single Family Residential Industrial Multi-unit Residential Mixed Use Public Project Phase: Project Description: Total Project Site Area = (a) Total New Impervious Surface Area = (b) Total Replaced Impervious Surface Area = (c) Total Existing Impervious Area = (d) Total Impervious Area of Completed Project = (e) Net Impervious Area: (a+b) – (c-d) = OR where (c-d) is a negative number: (a+b) = Your project is NOT subject to Post Construction Requirements if… Step 2  Area (a+b) of project is < 2,500 square feet – Done OR  Area (a+b) of project is > 2,500 square feet, and is a project type listed below ( type) – Done  Road & parking surface repair – slurry & fog & crack seal, pothole & spot patching, overlay & resurfacing & other damage repair with no expansion  Road & parking shoulder grading  Road & parking cleaning, repairing, maintaining, reshaping, regarding drainage systems  Sidewalk & bike path / lane project – no other impervious surface created and runoff is directed to vegetated area  Curb & gutter improvement or replacement – no other impervious created  Underground utility project – surface replaced in kind  Utility vaults – Ex: lift stations, backflows  Fuel storage – above ground with spill containment  Photovoltaic systems – on existing impervious surface, over pervious surface with vegetated cover, buffer strip at the most down gradient row of panels  Second story – no increase in building footprint  Decks & stairs & walkways – raised with space below for drainage  Temporary structures – in place less than 6 months  Trails and pathways, where no other impervious surfaces are replaced or created, and built to direct stormwater runoff to adjacent vegetated areas. Form revised: July 12, 2016 Chris Allen New attached ADU 619 grove Street, San Luis Obispo, CA 93405 001-056-052 R-1 New Construction This project consists of the construction of a new 2-story 920 S.F. attached accessory dwelling unit at the rear of an existing S.F.R. 3,589 S.F. 646 S.F. 230 S.F. 1,704 S.F. 2,350 S.F. 876 S.F. 4 4 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 WASTEWATER FLOW OFFSET APPLICATION Implementing City of San Luis Obispo Municipal Code Section 13.08.396 (Please Print) City Application #: Property Address: Applicant Name/Point of Contact: Phone Number/Email Address: Applicant Signature: Date: Required Wastewater Flow Offset: gallons per day or laterals Completed Sewer Lateral Replacements (provide address and City encroachment permit number for each offset)*: 1. 2. 3. 4. 5. *NOTES: 1) All permit work for sewer lateral replacements must receive final sign off to qualify as a wastewater flow offset. 2) Wastewater flow offset must be completed prior to a project ’s Building Permit issuance. City of San Luis Obispo Contact: Utilities Engineer Phone: 805-781-7215 Email: wastewateroffset@slocity.org OFFICIAL USE ONLY: Verification (Sign): (Print): Title: Date: BLDG-2981-2025 619 Grove Street, San Luis Obispo, CA 93401 Chris Allen 8052865186 cwa.arch@gmail.com 03/02/2026 150 619 Grove Street, San Luis Obispo, CA 93401 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 City of San Luis Obispo Wastewater Flow Offset Application Page 2 Application #: Property Address (or Addresses): WASTEWATER FLOW OFFSET CALCULATION WORKSHEET Residential Development1: Residential Units Proposed (in EDU): Residential Wastewater Flow (# EDU x 150 gpd): RESIDENTIAL FLOW TOTAL (gallons per day): Non-Residential Development2: Commercial Square Footage: Industrial Square Footage: Manufacturing Square Footage: Business Park Square Footage: Hotel/Motel Rooms: Non-Residential Wastewater Flow2: NON-RESIDENTIAL FLOW TOTAL (gallons per day): TOTAL WASTEWATER FLOW OFFSET (gallons per day): NOTES: 1.EDU = Equivalent Dwelling Unit. One single family residence 1,200 square feet or greater equals one EDU. 2.Wastewater generation factors for residential and non-residential development are provided in the City’s Engineering Standards, Uniform Design Criteria. (For Select Building Projects Less Than 1 Acre) PURPOSE: This plan can only be used for minor building projects (SFR - new, remodels, additions; and/or commercial remodels). Newly constructed commercial buildings under 2019 CalGreen Codes require the development and implementation of a WPCP similar to the standards of a State submitted SWPPP. This plan is only to serve as a guide, if the applicant elects to use it. The BMPS specified herein shall be considered just the “Minimum BMPs” and during the course of the project additional BMPs (Necessary BMPs) may be required to protect water quality. Please note that an in-fill new single family home project may require additional plan elements. This plan shall be used in accordance with CGP 2009-0009-DWQ, City Stormwater Permit & 2019 CalGreen Building Codes. GENERAL INFORMATION: WPCP Plan for Minor Building Projects) 1 of 4 Project Address: ________________________________________________________________________ Description of Work: ___________________________________________________________________ _____________________________________________________________________________________ Estimate total disturbed soil areas in square feet: __________ ** Erosion & Sediment Control Measures are required. Applicant’s Name: __________________________________ Applicant’s Tele No. (____) _____-_________ Emergency Contact: ______________________________ Tele: (___) ____-_____ Cell: (___) _____-______ Contractor’s Name: __________________________________ Contractor’s Tel No. (____) ____-_________ Contractor’s Mailing Address: ______________________________________________________________ (Street Address)(City)(State)(Zip) Type of Project - Check One Commercial / Industrial:  Alternations  New Con.  Site-work  Tenant Improvement  Other: __________________________________________________________________ Residential:  Additions  New Con.  Remodel  Other: _______________________ SCHEDULE: Anticipated Project Schedule (Calendar Days & Hours): Calendar days: __________________________________________________________________________ Hours: (From) ________________________________ (To) ______________________________________ BEST MANAGEMENT PRACTICES OR “BMPS” are procedures that help prevent pollutants from entering the City’s stormwater conveyance system and creeks. Indicate by checking ALL ANTICIPATED BMPS that must be incorporated into the project to ensure the protection of waterways and stormwater conveyance systems (i.e. gutters, streets, storm drain inlets, storm drains, catch basins, creeks, culverts and seasonal streams). Informational brochures on various project types and BMPs are available on the City website listed herein. For detailed information on the Best Management Practices listed herein refer to: Ca General Construction Permit Ca Green Building Codes Ca State Water Resources Control Board Ca Stormwater Quality Association* Caltrans Stormwater Pollution Templates Caltrans Supplement to Traffic Control Guide City of San Luis Obispo BMP Guides* City of San Luis Obispo Municipal Code City of SLO Stormwater Management Plan City of SLO Waterway Management - Plan I City of SLO Stream Management & - Plan II City of SLO Drainage Design Man. - Plan III City of SLO WPCP Guide* City Specifications Construction Industry Compliance Asst Center State Specifications - DOT http://www.waterboards.ca.gov/water_issues/programs/stormwater http://www.bsc.ca.gov/CALGreen/default.htm http://www.swrcb.ca.gov/water_issues/programs/stormwater http://www.casqa.org/ http://www.dot.ca.gov/hq/construc/stormwater/templates1.htm http://www.dot.ca.gov/hq/traffops/signtech/mutcdsupp https://bit.ly/3rWDzAa http://www.codepublishing.com/ca/sanluisobispo/ https://bit.ly/3sIS3m9 https://bit.ly/3oX9vlR https://bit.ly/3sJBE0V https://bit.ly/3uWmice https://bit.ly/3GYMpRY https://bit.ly/3t8NNOc http://www.cicacenter.org/swt/swt2.cfm?st=CA http://www.dot.ca.gov/hq/esc/oe/standards.php  Proximity to Storm Drains, Creeks & Known Underground Springs or Seeps: If the project site is within close proximity (< 150’) to a creek, storm drain inlet down gradient of the site and/or includes underground springs or seeps on site, the site plan may need to include the locations of each and additional specific BMPs may be required throughout the course of the project. Please consult with a Qualified Professional and/or Building Staff for guidance. Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 619 Grove Street, San Luis Obispo, CA 93405 of an existing single family residence. This project consists of the construction of a new 2-story 920 SF attached accessory dwelling unit at the rear 490 John Rourke 805 440 Chris Allen 286 5186 Monday through Friday 7 am 5 pm 80 4973 November 1, 201 November 2, 201 November 6, 201 November 8, 201 REVIEWED FOR CODE COMPLIANCE City of San Luis Obispo Building & Safety Division March 31, 2026 WPCP Plan for Minor Building Projects 2 of 4 ANTICIPATED BMPS NOTE: A “” indicates mandatory BMPs for all projects. Good Housekeeping: Keep site clean & organized at all times.  Pre-inventory BMPs: Develop a list all materials to be used on site to determine proper storage to avoid exposure to the elements as appropriate.  Material stockpile BMPs  Chemical storage BMPs  Inclement weather – materials storage BMPs  Impervious surface sweeping BMPs  Spill management & reporting BMPs. Waste Management Plan: All waste products must be containerized & covered at all times.  Waste management BMPs  Concrete, paint, plaster residue BMPs (lined washout pit, cover during rain events)  Hazardous spill management BMPs  Landscape materials BMPs  Potential pollutant source list: Detailed list of chemicals, solvents, paints & fertilizers to be used on the site.  Painting BMPs (lined washout pit, cover daily)  Completed City C&D Plan  Portable toilet BMPs  Equipment / vehicle BMPs Erosion Control Measures - to prevent sediment from becoming dislodged due to rain & wind event.  Riparian protection BMPs  Temporary soil stabilization BMPs  Temporary curb access BMPs  Vegetation preservation BMPs  Slope stabilization BMPs  Wind erosion BMPs  Dust control BMPs  Permanent soil stabilization BMPs  Phased construction BMPs  Steep slope BMPs  Post storm erosion control BMPs Sediment Control Measures – to control & detain dislodged sediment from leaving the site.  Creek protection BMPs  Site perimeter BMPs  Sediment basin BMPs  Stabilized construction exit(s) / entrance(s)  Storm drain inlet protection BMPs  Waterway & stabilized drainage way BMPs  Rapid soil stabilization BMPs  Advanced settling devices  Post storm event sediment control BMPs Run-on & Run-off Control Measures: Overland flow of storm water both on and off-site must be effectively managed.  Stormwater run-on BMPs  Stormwater run-off BMPs Non-Stormwater Management: For work performed in the street, or to temporarily store materials in the street or on the sidewalk you must secure an encroachment permit.  Equipment tool washout BMPs  Encroachment permits  Potential non-stormwater discharge BMPs  Saw-cutting BMPs  Scheduling BMPs Site Schematic: To reflect the location of all BMPs to be used on site. For example, depict the location of all perimeter control measures, such as silt fencing or straw wattles on a schematic.  For all construction projects with outside activities. Water Efficient Landscape Plans Submittal: For new construction sites a water efficient landscape plan may be required.  Refer to Utilities Conservation Post Construction Stormwater Devices  Pre & post stormwater run-off calculation  A post construction maintenance plan  A private stormwater conveyance system agreement, and  A post construction site schematic required Inspect, Maintain, Clean, Repair & Report – all site BMP’s on active and inactive construction sites weekly. Repairs must be made as necessary. Document all activities in a log.  Weekly inspection schedule  Pre & post storm event inspections  BMP cleaning schedule  BMP maintenance schedule  BMP repair protocol  Documentation & records management protocol  Reporting protocol Project Specific BMPs  _________________________________  _________________________________  _________________________________  _________________________________  _________________________________  _________________________________ Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division 919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 WPCP Plan for Minor Building Projects 3 of 4 SITE SCHEMATIC Required for all projects that include grading activities include a reasonable sketch depicting where all required and necessary BMPs shall be placed on and off site. Be sure to include: a directional arrow, slope directions reflecting after grading is complete, scale used, the location of all structures on site, the location of all waterways on and / or abutting the site, location of closest storm drain inlet, frontage and side streets and wild lands. Note additional requirements (i.e. erosion and grading plans, post construction stormwater device elements) may be required, so please refer to City Building staff for direction. Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 03/15/2022 WPCP Plan for Minor Building Projects 4 of 4 OFFICE USE ONLY: Received By: _______________ Date: __________ Approved By: _______________ Date: ____________ Denied: By: _______________ Date: __________ Comments: ___________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ PROJECT FEE: _____________ WPCP PLAN FOR BUILDING PROJECTS LESS THAN 1 ACRE The following sections of the City Municipal Code, City Standard Specifications, Storm Water Management Regulations, Green Building Codes and Fish & Game Regulations shall be reviewed by the permittee, and the permittee shall receive approval of this Minor WPCP prior to the commencement of work on the site. Plan BMPs shall be implemented on site at all times and verified for compliance. Permittee is required to maintain a log of all routine inspections, cleanings, maintenance and repairs made to all BMPs on site at all times for review by any representative of the City upon request. Failure to adhere to the WPCP, State and Federal Regulations may result in a Notice of Violation and/or an Administrative Citation and/or a Stop Work Order issued until the site is in conformance with the requirements of this plan. APPLICABLE SPECIFICATIONS: San Luis Obispo Municipal Code 8.04 Solid Waste Disposal Title 12 Streets, Sidewalks and Public Places 12.08 Urban Storm Water Quality Management and Discharge Control 12.23 Creek Protection Ordinance 13.08.130 Stormwater & unpolluted drainage 15.04.010 All disturbed surfaces 17.17.05 Neighborhood preservation City Specifications Section 3-1.03A, Encroachment Permit 4-1.07 Work Site Maintenance 6-1.03 Storage of Materials Section 7-1.01G Water Pollution Building Regulations J103.1 & J103.2 – Grading permits required City Specifications (Continued) Section 1010B, Uniform Design Criteria – Drainage and Erosion Control 19-1.07 Sawcutting 20.3 Erosion Control Storm Water Regulations Federal Water Pollution Control Act (CWA) California Construction Stormwater Permit California Porter Cologne Act of 2002 California Green Building Codes (Chp 4 & 5) City of SLO WPCP Guide City of SLO Construction BMP Guide Fish and Game Regulations: 1600, 1602, 5650, 5651 & 5652 I agree to follow the requirements as set forth in this Guide (WPCP), the City of San Luis Obispo’s Stormwater Management Plan, the State of California’s General Construction Permit, California Green Building Codes (Chapters 4 & 5) the Federal Clean Water Act and all applicable specifications. In addition, I understand and agree to the following: (1) Dynamic Plan: additional BMPs, both temporary and permanent may be required during the course of the project at the discretion of the City Inspector(s) in order to ensure the protection of local water quality, (2) it is permittee’s obligation to take additional corrective actions when required to protect local water quality, (3) failure to comply with all the requirements could cause the permit to be revoked; the issuance of a stop work order, a notice to comply, a notice of violation and/or a citation; (4) the doing of any work under this permit shall constitute an acceptance of the provisions of this permit and all attachments and documents referenced herein, (5) a copy of this signed approved Guide shall remain at the job site at all times available for review by any public official, and (6) overland flow storm water run-off & run-on has been adequately designed for & managed. Applicant: Permit #: Check One:  Owner  Contractor  Design Professional  Legal Representative Signature: Date: If you require assistance in completing this “Plan” please contact Notes: An * indicates a construction reference source specific to Stormwater BMPs. Please refer to the City’s website for “BMP Descriptions for Minor Building Projects” handout. Use of this template plan is at the discretion of City personnel. (805) 781-7180 Water Pollution Control Plan (WPCP)Community DevelopmentBuilding and Safety Division919 Palm Street, San Luis Obispo, CA 93401-3218 T 805.781.7180 F 805.781.7173 www.slocity.org 2019 2019 03/15/2022 12/19/2025 Chris Allen Stri'Lur$,pplfipo Buildlng & Safot DivlElm'919 Palm StEot'San Luls Oblspo'CA 93401-3218 School Fee Payment Certification Email this form to alivingston@slcusd-org and then call 805.549 -1213 or email for an in order to paY fees. The City cannot issue a buitding permit untilthe fee required by the san Luis coastal unified school District has been paid' T applicant is responsible for taking this form to the school distriit offices at 1500 Lizzie Bldg c' The school district will determin if a fee is required, compute and-collect the fee from the applicant, and certify payment in part "C" of this:form. The applicant must return this foftn to the Building Division "nJ p"y perrnit rbes before the uuiuing permit can, be issued. The phone numbe for the school district is (805) 549'1213. A. APPLICANT AND PERMIT INFORMATION PermitNirmber: BLDG-2981-2025 Applicant Name: John Rourke Assessor's Parcel Number:Qgl'08&929 Project Address: B. BUILDING TYPE & SIZE INDICATED BY PERMIT APPLICATION attached- AlUAddition - ADUBullding Type: Floor Area: Building # New SQFT # Demo SQFT TotalSQFT Residential: Gommercial: 920.00 0.00 0.00 0.00 920.00 0.00 Total:920.00 0.00 920:00 it application reviewed bY: Marah 12.2O26 Vanessa Coordinator Date C. SCHOOL DISTRICTVERIFICATION OF FEE PAYMENT I hereby certiry that the required development fee has been paid to the San Luis Coastal unified School District for the building described above' AB 2926 fee: Sq. Ft.Qeo x ree 5'l3 ,s 4, ? 5bl+c s L6, ?5b ' 4o Signature f€<4r^4 TOTAL FEE CALCULATED Date 3 ,3o. )-.6 ffi,:. 1 Buitding & safety Division co.*.rr.tion p"r*itAoori""tiot Community Devetopment T 805'78'l -7180 919 Patm Street, San Luis Obispo, CA 93401-3218 F Ao5'-/81 '7182 #1 IDENTIFY YOUR BUILDING PROJECT Property Address { 14 G ry, g: Assessor's Parcet# Property Owner Name i-/-- ) .r7., tr-air. Phone Number:Pa <- t//16 4rz7 Owner's Maiting Address l-l Li"unted Design Professional I Non-ticensed Designer (when altowed by statues)or Name:License No Phone:Address Description of work of not mE ore lhan flve hundred dollars ($500) l, as owner of the ProPe rty, or my emPloYees with wag es as their sole compensation, will ool-latr or portion of the work, and the structu re is not iniended or offered for sale. (Section 7044, Busin ess and Professions Code: The Contractors;State License Law does not aPPIY to an owner of the property who, through employees ' or personal effort, builds or improves the property, Provided that ihe improvements are not intended or offered for sale. lf, however, the building or improv ement is sold within one year of completion,the Owner-Builder will have the burden of proving that it C the Labor Code, I shail forthwith comply with those provtstons' [ 3u - ceNsrFucrtoN t rrunrun AcrNc* Decranqrtoru | hereby affirm under penalty of periury that there is a construction lending ffin"y r- tr* purforrnun." or trt" work for which this permit is issued (Sectron 3097, Civil Code) as follows Signature-Date.Print Name reviseC 12i'1Ai2a24 Requires owner br:ii formuires separate authorizailon cnty oF san l-uls otslspo Building & SafetyDivision r 9't9 Palm Street I San Luis Obispo, CA93401 r (805) 781-7180 r (805) 78"1'7182 Fax Dear PropertY Owner: Building Permit Application No IN N EPfvlr ?1qo -2g?r has been submitted in your name listing yourself as the builder of the property improvements sPecifi ed at er Acknowledgm ent and lnformation Verification Form to make You aware of YourWe are providing You with this responsibilities and possible risk you may incur by having this Permit issued in your name as the Owner-Builder. We will not issue a building permit until You have rea official address indicated above. approval of the permitting authority. d, initialed your understanding of each provision, signed,and returned this form to us at our An agent of the owner cannot execute this notice unless You the property owner, obtain the prior ,4 DIRECTTONS: Read and initial each statement below to sEnrfy yw understand or verify this information" kffff:.;;.i,:if:i"#,1f;ii;;:;'i:.':?X'"l"#'il'":",:X";I:,iii3:['":]il:':?:]i!i3;?:l;';f,1iTi,'l:'l'",'."i,TJj'fl;'::[iTi: serious flnancial risk for any injuries sustained by an unlicensed person and his or her'employees while working on my property My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner-Builder and am aware of the limits of my insurance coverage for iniuries to workers on my property. ',/a,//n.he..l understand building permits are not required to be signed by property owners unless they are responsible for the consiruction and are not hiring G licensed Contractor to assume this responsibility. ,4 Z , I understand as an .owner-Buildef, I am the responsible party of record on the permit. I understand that I may protect myself from potential frffi;"i *[Ov niii"g a ticensed Contractor and having the permit filed in his or her name instead of my own' 4 I understand contractors are required by law to be licensed and bonded in california and to list their license numbers on permits and contracts' -Z t understand if I employ or otherwise engage any persons, other than california licensed contractors, and the total value of my construction is at €":,"fl,,"i.";:;;;,"1'ol"iiurr (gsob), incruoing laboiand mjteriats, I may be considered an "emplover'' under state and federal law' A I understand if I am considered an ,,employe/' under state and federal law, I must register with the state and federal government' withhold payroll taxes, provroe worKers compensailon disability insurance, and contribute to unemployment compensation for each "employee " I also understand my failure io abide by these laws may subject me to sertous financial nsk' ,4Zd I understand under california contractors, state License Law, an owner Builder who builds single{amily residential structures cannot legally buito tnem with the intent to offer them for sale, unless a// work is performed by licensed subcontractors Jnd the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor' /--" I understand as an owner-Builder rf I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries *-;"i;;;ry-rrO""qr""t owner(s) that result from'any latlnt constructton defects in the workmanship or materials' 4^ | understand I may obtain more information regarding my obligations as an "employer'' from the lnternal Revenue service' the United states srnall Business Administration, the california Department of Beneflt payments, and the batifornia Division of lndustrial Accidents l also understand I may contact ihe california contractors,state License Board (cSLB)at 1-800-321-CSLB (2752) or wrrwv.cslb.ca.govfor more information about licensed contractors. / ,o.l am aware ol and consent to an owner-Builder building permit applied for in my name, and understand that I am the party legally and fficially responsible for proposed construction activity at the following project address: vtq ww2 fu,1 . I agree that, as the party legally and financially responsible for this proposed construction activity, lwill abide by all applicable laws and requiremenis that govern Owner-Builders as well as employers' 44i I agree to notify the rssuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed coniractors are regulated by laws designedio protect the public. lf you contract *ith sot"one who does not have a license' the contractors, state License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint Your only remedy against unlicensed contractors may be in civrl court. lt is aLo important for you to und-erstand that if an unlicensed contractor or employee of that individual or firm is inlured while working on your property, you may be held liabte for damages. lf you obtarn a permit as owner-Builder and wish to hire contractors, you will be responsible for verifying whetheioi not those contra"ior. ur" propJrly licensed and the status ol their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property o*ier's driver's license, form notarization' or other verification acceptable to the agency is required to be presented whei the permit is rssued to verify the property owner's signature. Print Name of ProPertY Signature la/-21 'nI /)- Date Sifi'ttrs onrs po Building & Safety Division . 919 Palm Street. San Luis Obispo, CA 93401-3218 BUILDING PERMIT Electric Service Upgrade EPM-2748-2025 lssuance Date: 1 1 12412025 CAI, IFORNIA Project Address: 619 Grove St Unit or Suite(s): Project Description: PANEL UPGMDE 100A-200A Owner: John Rourke Mobile: (805) 44-0-49 Assessor's Parcel Number: 001-056-052 Square Footage' 0.00 Legal Description: Fire Spdnklers: Census: Occupancy: Stories 0.00 Qs(s\s1r. 2022 Dwelling Units:Motel Rooms: Construction Type: Valuation Grou Type sq.Ft Factor Valuation Manual $4,000.00 Fees Payments Receipt #Fee Name Fee Amount Date Amount Electric Service Upgrade (up to $166.94 11t24t25 48,828-11-24-2025 Total Paid: $166.94 $166.94Total Fees:$166.94 PIan Check Account Payment by Gontact Contact Name Account Name Status Total Credits Total Debits Account Balance Total Account Balance: Balance Due $0.00 Legal Declarations#2 IDENTIFY WHO WILL PERFORM THE WORK2b - OWNER-BUILDER'S DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for thereason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city orcounty that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permitto file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter g (commencing withSection 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption.Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).):l, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and ProfessionsCode: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projectswith a licensed Contractor pursuant to the Contractors' State License Law).By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion ofthe improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entiretyby licensed contractors. I understand that a copy of the applicable law is available upon request or athttp://www.leginfo.ca.gov/calaw.html.#3 IDENTIFY WORKERS' COMPENSTATION COVERAGE AND LENDING AGENCYWARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to$100,000, in addition to the cost of compensation, damages as provided for in section 3706 of the labor code, interest, and attorney's fees.I certi! that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to theworkers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of theLabor Code, I shall forthwith comply with those provisions.#4 DECLARATION BY CONSTRUCTION PERMIT APPLICANTBy my signature below, I certiff each of the following:I am the Property Owner.November 24,2025Signature of, Authorized Agent or OwnerDate FIRE DEPARTMENT PLAN REVIEW PROJECT DESCRIPTION: INSTALL RESIDENTIAL FIRE SPRINKLER SYSTEM. PROPERTY OWNER: ADDRESS: 619 GROVE STREET, SAN LUIS OBIPSO, CA 93401. APN: 001-056-029 APPLICATION NUMBER: #2568-2023 PLANS EXAMINER: JASON BERES PROJECT MANAGER: CENTRAL COAST FIRE PROTECTION. DATE: 10/16/2023 REVIEWED FIRE PROTECTION PLANS SHALL MEET THE FOLLOWING CONDITIONS PENDING PERMIT ISSUAANCE: 1) Rough inspection and hydrostatic test required in accordance with NFPA 13D. 2) Flow test required for the fire sprinklers located inside the hydraulic design area (Remote Area No.1). Conditions subject to field verification by City Building Department staff. 3) Final Inspection Required. Approved plans shall be available on-site for final inspection. Deviation from approved plans will require permission from authority having jurisdiction. 4) Please contact City Building Department to set up all inspections (805)781-7180. c{Iy os Lt-ils oBIs po 3LD U - tao3-r-oee q bnwsh"cry CAf,IFORIV Euildlng & SEhry . 91 I Palrn Strost . San lrl(sObispo,cA gr40.t-321e Plffi trlticrbar Apts,lQdtfon Dqte: Addrees: tnL Proporty Owner truo -',ffirufrf,urqL"€eryr j'4, oeearo*on:S;14,r.),D\,{)W u Conlractor Phone Number bue Polyethylenerf LEterErsize: 3/U' stacttc pressuru' 90 pl i Flre Hydr€ ntt: W.tgr Fressuer Zone: COMMENTS: CcooerEl Lateral Length Main to Meter: 30 , Pressure Recorded frorn aUdress: /gS House Hose Btb& P o lybertylen en Curb StopE I tj 'fj I I i i I I I Galvfl Manlfoldtl ,VrlFe ltame partment Phon€ Numb€r lnted: August 13,2013 - pL Spdnkler tD R_Rev G.rpt m."{Y*{ Paga 1 of I; r.., Building & Safety Division Construction Permit ApplicationwT 805.781.7180 F 805.781 .7182 #I IDENTIFY YOUR BU]LDING PROJECT Property Address Property Owner: 619 Grove Street Parcel #001 -056 _029 Owner's Mailing Addres ELicenseO Design Professional ln Responsible Charge or nNon-Licensed Designer (when allowed by statutes) Name: Central Coast Fire Suppression, LLC_ * ,, -License no. 1 105979 Add 83 12th. St., Paso Robles, CA 93446 805-440-7013 Description of work: lnstall Fire iPrinkleJ"Fy,glem Dwelling Units: 1 Occupancy Group Type_ Fire Sprinklers Yes Pp6js6t Value $ 2 000 Floor Area (Sq. Ft): Living _ Garage Deck Other Permit Types Required:f]Building !Mechanical lElectrical [Plumbing lGrading-C.Y - lDemolition Select Plan Check Consultant: ICCC [wtllonru laUnrnu VERTTAS or with Section 7000 Division 3 of the Business I hereby affirm under penalty of perjury that I am licensed under provisions of and Professions Code, and my license is in full force and effect. I Coast Fire S ton LLC class c-16 License No.1 1 05979 city or county that requires I permit to construct, permit to lile a Community Development 919 Palm Street, San Luis Obispo, CA 93401-3218 John Rourke Phone signed statement that he or of Division 3 of the Business she is Section 7000)and Professions Code) or that he or she ls exempt from licensure and the basis for the alleged exemptlon. Arlwiolation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penally of not more than tive hundred dollars ($500).): lll, as owner of the property, or my employees with wages as thelr sole compensation, will do llall of orl_lportions ol the work, and the structufe is not intended or offered for sale. (Section 7044, Business and Professions Code: The Conlractors' State License Law does not apply to an ownsr of property who, lhrough employees' or personal effort, builds or improves the property, provided that the improv€ments are not lntended or offered for sale. lf, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that jl3ras not built or improved for the purpose of sale) ll t, as owner of the property, am exclusively contractlng with licensed Contractors to construct the proJect (Section 7044, Business and Professions Code: The Contractors' State Lic€nse Law does not apply to an owner of property who builds or improves thereon, and who contracts for lh-e projects with a licensed Contractor pursuant to the Contractors' State License Law). ll t am exempt from llcensure under the Contractors' State Llcense Law for the following reason By my signature below I aoknowledge that, except for my personal residence in which I must have resided at least one year prior to completion of improvements covered by this permit, I cannot legally sell a struciure that I have built licensed contractors. I understand that a copv ofthe aoolicable law is available upon #3 IIIENTIFY WORKERS' COMPENSTATION COVERAOE AND LENDING AGENCY (Complete 3a and 3b) lVARfft \tC: Failure to secure urorker$' conp€n$ation coverage is unJawful, cnd slrall subject an ernpltiyer to criminal pencllier ond 6rvil flnes up to $100,000, in addition to ihe cost of compensalion, damages as provided lcr in seclion 3?06 of lho labo. cads, intsre$t, and aitorney's fees. I hereby atfkm under penalty of perjury one of the following declarations: to solflnsure for workers' compensation, issued by ths Director of lndustrial Relalions for by Section 3700 of the Labor Code, for the performance of the work for which ihis permit is issued. Policy No. C-16 I have and will maintain workere' compensation insurance, as required by Section 3700 of lhe Labor Code, for the performance of the work for this permit is issued. My workers' compensation insurance carrier and pollcy number are: any person in subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. th.OOil&+RltCTl&IN Lf;ilDI{G &GEt{gY OGCtinAl}gtiI I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Section 3097, Civil Code) as follows: Lender's Name and Addre$ _ #4 DECLARATION BY CONSTRUCTION PERMIT APPLICANT By my signature below, I certiry each of the following: t am I a California licensed contractor orltne property owner* or! authorized to act on the property owner's behaf *. I have read this permlt application and the information I have provided is conect. I agree to comply with applicable city and county ordinanc€s and state as an owner-builder if it has not been constructed in its entirety by request or at htlrx#kinil,|esfulis"se.aer$1s81*tr.t*ml. consent laws Thls relating permit is to be issued in the name of Llcensed Contractor responsible and liable for the construction. tr'n, pr.. Randy Shriver ,ignature of this city nty to enter the above-id€ntified property for inspection purposes. e permit holder of record who will be 9t19t23 to building construction. I authorize x$s,(,errct't # * requircs saparate verification form **roqur'res sepa rate authorizatian farm Revised 2014 $iri'Lur.q.gpl$po BUILDING PERMIT Fire Sprinklers FtRE-2568-2023 lssuance Dale: 1 12212025Building & Safety Division . 919 Palm Street. San Luis Obispo, CA 93401-3218 ProjectAddress: 619 Grove St Unit or Suite(s): Project Description: INSTALL FIRE SPRINKLER SYSTEM Contractor: CENTML COAST FIRE SUPPRESSION LLC RANDY SHRIVER Business: (805) 440-701 3 License Type: California State Contractor License Assessor,s Parcel Number: 001-056-029 Square Footage: 0.00 Legal Description: License Number: 1105979 Classification: C16 - Fire Protection Contractor Owner:John Rourke Mobile: ( Valuation Group Tvpe sq. Ft Factor Valuation Fire Sprinklers:Stories 0.00 CodeYear'. 2022 Dwelling Units Motel Rooms: Construction Type:Census: Occupancy: Fees Payments Receipt #Fee Name Fee Amount Date Amount Fire sprinkler consolidated - new lT Surcharge $1,156.29 $35.27 10t17t24 M,998-10-17-2024 Total Paid $1,191.56 $1Jsrs6 Total Fees:$1,191.56 Plan Gheck Account Payment by Gontact Contact Name Account Name Status Total Gredits Total Debits Account Balance Total Account Balance: Balance Due:s0.00 Legal Declarations #2 IDENT]FY WHO WILL PERFORM THE WORK 2a - CALIFORNIA LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I commencing with Section 7000 of Division 3 of the Business and Professions Code, and my license is in full force and effect. #3 IDENTIFYWORKERS' COMPENSTATION COVERAGE AND LENDING AGENCY WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in section 3706 of the labor code, interest, and attorney's fees. I certiff that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. #4 DEGLARATION BY CONSTRUCTION PERMIT APPLICANT By my signature below, I certifo each of the following: I am a CA Licensed Contractor. Januaw 22 sig , Authorized Agent or Owner Date ,2025 SLO 22-0042PARCEL MAP GROVE STREET PARCEL 1PARCEL 2WILSON STSLO 22-0042PARCEL MAP CLTA Preliminary Report Form Order Number: 4001-7003465 (Rev. 11/06) Page Number: 1 First American Title Page 1 of 9 First American Title Company 899 Pacific Street San Luis Obispo, CA 93401 California Department of Insurance License No. 151 Linda Richardson MBS Land Surveys Phone: (805)594-1960 Customer Reference: Title Officer: Lisa Irot Phone: (805)786-2042 Fax No.: (866)397-7092 E-Mail: lirot@firstam.com E-Mail Loan Documents to: Lenders please contact the Escrow Officer for email address for sending loan documents. Owner: Michael Rourke Property: 619 Grove Street San Luis Obispo, CA 93401 PRELIMINARY REPORT In response to the above referenced application for a policy of title insuran ce, this company hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a Policy or Policies of Title Insurance describing the land and the esta te or interest therein hereinafter set forth, insuring against loss which ma y be sustained by reason of any defect, lien or encumbrance not shown or referred to as an Exception below or not excluded from coverage pursuant to the printed Schedules, Conditions and Stipulations of said Policy forms. The printed Exceptions and Exclusions from the coverage and Limitations on Covered Risks of said policy or policies are set forth in Exhibit A attached. The policy to be issued may contain an arbitration clause. When the Amount of Insurance is less than that set forth in the arbitration clause, all arbitrable matters shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. Limitations on Covered Risks applicable to the CLTA and ALTA Homeowner's Policies of Title Insurance which establish a Deductible Amount and a Maximum Dollar Limit of Liability for certain coverages are also set forth in Exhibit A. Copies of the policy forms should be read. They are available from the office which issued this report. Please read the exceptions shown or referred to below and the exceptions and exclusions set forth in Exhibit A of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered. It is important to note that this preliminary report is not a written representation as to the condition of title and may not list all liens, defects, and encumbrances affecting title to the land. Please be advised that any provision contained in this document, or in a document that is attached, linked or referenced in this document, that under applicable law illegally discriminates against a class of individuals based upon personal characteristics such as race, color, religion, sex, sexual orientation, gender identity, familial status, disability, national origin, or any other legally protected class, is illegal and unenforceable by law. This report (and any supplements or amendments hereto) is issued solely for the pur pose of facilitating the issuance of a policy of title insurance and no liability is assumed hereby. If it is desired that liability be assumed prior to the issuance of a pol icy of title insurance, a Binder or Commitment should be requested. Order Number: 4001-7003465 Page Number: 2 First American Title Page 2 of 9 Dated as of June 15, 2023 at 7:30 A.M. The form of Policy of title insurance contemplated by this report is: ALTA/CLTA Homeowner's (EAGLE) Policy of Title Insurance and ALTA Ext Loan Policy if the land described is an improved residential lot or condominium unit on which there is located a one-to-four family residence; or ALTA Standard Owner's Policy (with Western Regional Exceptions) and the ALTA Loan Policy if the land described is an unimproved residential lot or condominium unit. A specific request should be made if another form or additional coverage is desired. Title to said estate or interest at the date hereof is vested in: Michael Rourke, an Unmarried Man The estate or interest in the land hereinafter described or referred to covered by this Report is: FEE The Land referred to herein is described as follows: (See attached Legal Description) At the date hereof exceptions to coverage in addition to the printed Exceptions and Exclusions in said policy form would be as follows: 1. Taxes and assessments, not examined. A.P.N.: 001-056-029. 2. A deed of trust to secure an original indebtedness of $600,000.00 recorded OCTOBER 14, 2022 as INSTRUMENT NO. 22-41261 OF OFFICIAL RECORDS. Dated: OCTOBER 12, 2022 Trustor: MICHAEL ROURKE, AN UNMARRIED MAN Trustee: FIDELITY NATIONAL TITLE COMPANY Beneficiary: SLO CAPITAL, INC. Order Number: 4001-7003465 Page Number: 3 First American Title Page 3 of 9 INFORMATIONAL NOTES Note: The policy to be issued may contain an arbitration clause. When the Amount of Insurance is less than the certain dollar amount set forth in any applicable arbitration clause, all arbitrable matters shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. If you desire to review the terms of the policy, including any arbitration clause that may be included, contact the office that issued this Commitment or Report to obtain a sample of the policy jacket for the policy that is to be issued in connection with your transaction. 1. This report is preparatory to the issuance of an ALTA Loan Policy. We have no knowledge of any fact which would preclude the issuance of the policy with CLTA endorsement forms 100 and 116 and if applicable, 115 and 116.2 attached. When issued, the CLTA endorsement form 116 or 116.2, if applicable will reference a(n) Single Family Residence known as 619 GROVE STREET, SAN LUIS OBISPO, CA. 2. According to the public records, there has been no conveyance of the land within a period of twenty four months prior to the date of this report, except as follows: A document recorded MAY 31, 2022 as INSTRUMENT NO. 22-22974 of Official Records. From: CHARLES G. KIRSCHNER, SUCCESSOR TRUSTEE OF THE DOLORES E. HERZOG REVOCABLE TRUST, U/D/T DATED JANUARY 9, 1998 To: MICHAEL ROURKE, AN UNMARRIED MAN NOTE to proposed insured lender only: No Private transfer fee covenant, as defined in Federal Housing Finance Agency Final Rule 12 CFR Part 1228, that was created and first appears in the Public Records on or after February 8, 2011, encumbers the Title except as follows: None The map attached, if any, may or may not be a survey of the land depicted hereon. First American expressly disclaims any liability for loss or damage which may result from reliance on this map except to the extent coverage for such loss or damage is expressly provided by the terms and provisions of the title insurance policy, if any, to which this map is attached. Order Number: 4001-7003465 Page Number: 4 First American Title Page 4 of 9 LEGAL DESCRIPTION Real property in the City of San Luis Obispo, County of San Luis Obispo, State of California, described as follows: ALL THAT PORTION OF BLOCK 1 OF PHILLIPS' ADDITION TO THE CITY OF SAN LUIS OBISPO, COUNTY OF SAN LUIS OBISPO, STATE OF CALIFORNIA, AS SUBDIVIDED FOR EDWIN GOODALL IN SEPTEMBER, 1887, ACCORDING TO THE MAP FILED IN BOOK A, PAGE 162 OF MAPS RECORDS OF SAID COUNTY, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHEASTERLY CORNER OF BLOCK 1 AS SAID BLOCK IS SHOWN AND DELINEATED ON SAID MAP; THENCE NORTHERLY ALONG THE WESTERLY LINE OF GROVE STREET, 50 FEET; THENCE WESTERLY AND PARALLEL WITH THE SOUTHERLY LINE OF SAID BLOCK, 120 FEET; THENCE SOUTHERLY AND PARALLEL WITH THE WESTERLY LINE OF GROVE STREET, 50 FEET TO THE SOUTHERLY LINE OF SAID BLOCK; THENCE EASTERLY ALONG THE SOUTHERLY LINE OF SAID BLOCK, 120 FEET TO THE POINT OF BEGINNING AND BEING PART OF LOTS 1, 2 AND 3 IN BLOCK 1, ACCORDING TO THE ABOVE MENTIONED MAP. APN: 001-056-029 Order Number: 4001-7003465 Page Number: 5 First American Title Page 5 of 9 Order Number: 4001-7003465 Page Number: 6 First American Title Page 6 of 9 NOTICE Section 12413.1 of the California Insurance Code, effective January 1, 1990, requires that any title insurance company, underwritten title company, or controlled escrow company handling funds in an escrow or sub- escrow capacity, wait a specified number of days after depositing funds, before recording any documents in connection with the transaction or disbursing funds. This statute allows for funds deposited by wire transfer to be disbursed the same day as deposit. In the case of cashier's checks or certified checks, funds may be disbursed the next day after deposit. In order to avoid unnecessary delays of three to seven days, or more, please use wire transfer, cashier's checks, or certified checks whenever possible. Order Number: 4001-7003465 Page Number: 7 First American Title Page 7 of 9 EXHIBIT A LIST OF PRINTED EXCEPTIONS AND EXCLUSIONS (BY POLICY TYPE) CLTA/ALTA HOMEOWNER'S POLICY OF TITLE INSURANCE [(07-01-2021) v. 01.00] EXCLUSIONS FROM COVERAGE The following matters are excluded from the coverage of this policy and We will not pay loss or damage, costs, attorneys' fee s, or expenses that arise by reason of: 1. a. any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) that restricts, regu lates, prohibits, or relates to: i. the occupancy, use, or enjoyment of the Land; ii. the character, dimensions, or location of any improvement on the Land; iii. the subdivision of land; or iv. environmental remediation or protection. b. any governmental forfeiture, police, or regulatory, or national security power. c. the effect of a violation or enforcement of any matter excluded under Exclusion 1.a. or 1.b. Exclusion 1 does not modify or limit the coverage provided under Covered Risk 8.a., 14, 15, 16, 18, 19, 20, 23, or 27. 2. Any power to take the Land by condemnation. Exclusion 2 does not modify or limit the coverage provided under Covered Risk 17. 3. Any defect, lien, encumbrance, adverse claim, or other matter: a. created, suffered, assumed, or agreed to by You; b. not Known to Us, not recorded in the Public Records at the Date of Policy, but Known to You and not disclosed in writing to Us by You prior to the date You became an Insured under this policy; c. resulting in no loss or damage to You; d. attaching or created subsequent to the Date of Policy (Exclusion 3.d. does not modify or limit the coverage provided under Covered Risk 5, 8.f., 25, 26, 27, 28, or 32); or e. resulting in loss or damage that would not have been sustained if You paid consideration sufficient to qualify You as a bona fide purchaser of the Title at the Date of Policy. 4. Lack of a right: a. to any land outside the area specifically described and referred to in Item 3 of Schedule A; and b. in any street, road, avenue, alley, lane, right-of-way, body of water, or waterway that abut the Land. Exclusion 4 does not modify or limit the coverage provided under Covered Risk 11 or 21. 5. The failure of Your existing structures, or any portion of Your existing structures, to have been constructed before, on, or after the Date of Policy in accordance with applicable building codes. Exclusion 5 does not modify or limit the coverage provided under Covered Risk 14 or 15. 6. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors’ rights law, that the tra nsfer of the Title to You is a: a. fraudulent conveyance or fraudulent transfer; b. voidable transfer under the Uniform Voidable Transactions Act; or c. preferential transfer: i. to the extent the instrument of transfer vesting the Title as shown in Schedule A is not a transfer made as a contemporaneous exchange for new value; or ii. for any other reason not stated in Covered Risk 30. 7. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake, or subsidence. 8. Negligence by a person or an entity exercising a right to extract or develop oil, gas, minerals, groundwater, or any other subsurface substance. 9. Any lien on Your Title for real estate taxes or assessments imposed or collected by a governmental authority that becomes due and payable after the Date of Policy. Exclusion 9 does not modify or limit the coverage provided under Covered Risk 8.a. or 27. 10. Any discrepancy in the quantity of the area, square footage, or acreage of the Land or of any improvement to the Land. LIMITATIONS ON COVERED RISKS Your insurance for the following Covered Risks is limited on the Owner’s Coverage Statement as follows: For Covered Risk 16, 18, 19, and 21 Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A. The deductible amounts and maximum dollar limits shown on Schedule A are as follows: Your Deductible Amount Our Maximum Dollar Limit of Liability Covered Risk 16: 1% of Policy Amount Shown in Schedule A or $2,500 $10,000 (whichever is less) Covered Risk 18: 1% of Policy Amount Shown in Schedule A or $5,000 $25,000 (whichever is less) Covered Risk 19: 1% of Policy Amount Shown on Schedule A or $5,000 $25,000 (whichever is less) Covered Risk 21: 1% of Policy Amount Shown on Schedule A or $2,500 $5,000 (whichever is less) Order Number: 4001-7003465 Page Number: 8 First American Title Page 8 of 9 ALTA OWNER'S POLICY [(07-01-2021) V. 01.00] CLTA STANDARD COVERAGE OWNER'S POLICY [(02-04-22) V. 01.00] EXCLUSIONS FROM COVERAGE The following matters are excluded from the coverage of this policy, and the Company will not pay loss or damage, costs, attorneys’ fees, or expenses that arise by reason of: 1. a. any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) that rest ricts, regulates, prohibits, or relates to: i. the occupancy, use, or enjoyment of the Land; ii. the character, dimensions, or location of any improvement on the Land; iii. the subdivision of land; or iv. environmental remediation or protection. b. any governmental forfeiture, police, regulatory, or national security power. c. the effect of a violation or enforcement of any matter excluded under Exclusion 1.a. or 1.b. Exclusion 1 does not modify or limit the coverage provided unde r Covered Risk 5 or 6. 2. Any power of eminent domain. Exclusion 2 does not modify or limit the coverage provided under Covered Risk 7. 3. Any defect, lien, encumbrance, adverse claim, or other matter: a. created, suffered, assumed, or agreed to by the Insured Claimant; b. not Known to the Company, not recorded in the Public Records at the Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; c. resulting in no loss or damage to the Insured Claimant; d. attaching or created subsequent to the Date of Policy (Exclusion 3.d. does not modify or limit the coverage provided under Co vered Risk 9 or 10); or e. resulting in loss or damage that would not have been sustained if consideration sufficient to qualify the Insured named in Sc hedule A as a bona fide purchaser had been given for the Title at the Date of Policy. 4. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors’ rights law, that the transaction vesting the Title as shown in Schedule A is a: a. fraudulent conveyance or fraudulent transfer; b. voidable transfer under the Uniform Voidable Transactions Act; or c. preferential transfer: i. to the extent the instrument of transfer vesting the Title as shown in Schedule A is not a transfer made as a contemporaneous exchange for new value; or ii. for any other reason not stated in Covered Risk 9.b. 5. Any claim of a PACA-PSA Trust. Exclusion 5 does not modify or limit the coverage provided under Covered Risk 8. 6. Any lien on the Title for real estate taxes or assessments imposed or collected by a governmental authority that becomes due and payable after the Date of Policy. Exclusion 6 does not modify or limit the coverage provided under Covered Risk 2.b. 7. Any discrepancy in the quantity of the area, square footage, or acreage of the Land or of any improvement to the Land. NOTE: The 2021 ALTA Owner’s Policy may be issued to afford either Standard Coverage or Extended Coverage. In addition to variable exceptions such as taxes, easements, CC&R’s, etc., the Exceptions from Coverage in a Standard Coverage policy will also inclu de the Western Regional Standard Coverage Exceptions listed below as numbers 1 through 7. The 2021 CLTA Standard Coverage Owner’s Policy will incl ude the Western Regional Standard Coverage Exceptions listed below as numbers 1 through 7. EXCEPTIONS FROM COVERAGE Some historical land records contain Discriminatory Covenants that are illegal and unenforceable by law. This policy treats any Discrimina tory Covenant in a document referenced in Schedule B as if each Discriminatory Covenant is redacted, repudiated, removed, and not republished or recirculated. Only the remaining provisions of the document are excepted from coverage. This policy does not insure against loss or damage and the Company will not pay costs, attorneys’ fees, or expenses resulting from the terms and conditions of any lease or easement identified in Schedule A, and the following matters: 1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or as sessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 2. Any facts, rights, interests, or claims that are not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records. 6. Any lien or right to a lien for services, labor or material unless such lien is shown by the Public Records at Date of Policy. 7. Any claim to (a) ownership of or rights to minerals and similar substances, including but not limited to ores, metals, coal, lignite, oil, gas, Order Number: 4001-7003465 Page Number: 9 First American Title Page 9 of 9 uranium, clay, rock, sand, and gravel located in, on, or under the Land or produced from the Land, whether such ownership or rights arise by lease, grant, exception, conveyance, reservation, or otherwise; and (b) any rights, privileges, immunities, rights o f way, and easements associated therewith or appurtenant thereto, whether or not the interests or rights excepted in (a) or (b) appear in the Public Records or are shown in Schedule B. 2006 ALTA OWNER'S POLICY (06-17-06) EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, c osts, attorneys' fees, or expenses that arise by reason of: 1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to (i) the occupancy, use, or enjoyment of the Land; (ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or (iv) environmental protection; or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1(a) does not modify o r limit the coverage provided under Covered Risk 5. (b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 6. 2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8. 3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under th is policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 9 and 10); or (e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value fo r the Title. 4. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors’ rights laws, that the tr ansaction vesting the Title as shown in Schedule A, is (a) a fraudulent conveyance or fraudulent transfer; or (b) a preferential transfer for any reason not stated in Covered Risk 9 of this policy. 5. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching between Date of Policy and the date of recording of the deed or other instrument of transfer in the Public Records that vests Title as shown in Schedule A. NOTE: The 2006 ALTA Owner’s Policy may be issued to afford either Standard Coverage or Extended Coverage. In addition to vari able exceptions such as taxes, easements, CC&R’s, etc., the Exceptions from Coverage in a Standard Coverage policy will also include the Wester n Regional Standard Coverage Exceptions listed below as numbers 1 through 7. EXCEPTIONS FROM COVERAGE This policy does not insure against loss or damage, and the Company will not pay costs, attorneys’ fees or expenses, that arise by reason of: The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclus ions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Cove rage: 1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or as sessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assess ments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 2. Any facts, rights, interests, or claims that are not shown in the Public Records but that could be ascertained by an inspecti on of the Land or that may be asserted by persons in possession of the Land. 3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and that are not shown by the Public Records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) wat er rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records. 6. Any lien or right to a lien for services, labor or material unless such lien is shown by the Public Records at Date of Policy . 7. Any claim to (a) ownership of or rights to minerals and similar substances, including but not limited to ores, metals, coal , lignite, oil, gas, uranium, clay, rock, sand, and gravel located in, on, or under the Land or produced from the Land, whether such ownership or rights arise by lease, grant, exception, conveyance, reservation, or otherwise; and (b) any rights, privileges , immunities, rights of way, and easements associated therewith or appurtenant thereto, whether or not the interests or rights excepted in (a) or (b) appear i n the Public Records or are shown in Schedule B. CODE CASE ACTIVITY REPORT CODE-000350-2024 FOR CITY OF SAN LUIS OBISPO Address:Closed Date:In ViolationStatus:619 Grove St San Luis Obispo, CA 93401 08/27/2024Opened Date:Steve SheatsAssigned ToCode EnforcementCase Type: Activity Date Created By Activity Type CommentsActivity Name 08/28/2024 8/29/24 - Compliance date of 9/28/24. Mailed to PO & SA via first class. Notice of ViolationSteve Sheats 09/16/2024 PO emailed and stated work was done prior to sale, was termite repair work and doesn't require a permit. I encouraged him to submit a Request for Director's Review if he wanted to contest the notice. CorrespondenceSteve Sheats 09/18/2024 Received 9/16/24Appeal to DirectorKrista Curry 12/05/2024 Settled outside of formal process per JMAppeal to DirectorKrista Curry Settled 02/24/2025 Emailed PO for update on plan submittal. Responded ETA within 1 month. CorrespondenceSteve Sheats 04/04/2025 Emailed PO for update on submittal. Responded they are still waiting on the structural from Justin Wolf. CorrespondenceSteve Sheats 06/02/2025 Emailed PO for update.CorrespondenceSteve Sheats 06/09/2025 Emailed architect for update. Responded submittal should happen next week. CorrespondenceSteve Sheats 07/07/2025 BLDG-1538-2025 submitted 7/2/25Building Application Submitted Steve Sheats 09/19/2025 Applicant has withdrawn applicationResearchSteve Sheats Emailed PO and architect for update on code case resolution. CorrespondenceSteve Sheats 04/20/2026 BLDG-2981-2025 issued 3/31/26Building Permit IssuedSteve Sheats Page 1 of 1City of San Luis ObispoJune 04, 2026 PLANNING APPLICATION Community Development Department • 919 Palm Street • San Luis Obispo, California 93401 • (805) 781-7170 Project Address and Assessors Parcel Number(s): What do you want to do? What is your final goal? Day Phone: Day Phone: Day Phone: The Applicant The representative The property owner Applicant (Who is proposing the project?): Applicant’s Address: Representative (if any): Representative’s Address: Property Owner (if other than applicant): Owner’s Address: Please send all correspondence to: By signing this application I certify that I have reviewed this completed application and the attached material and consent to its filing. I agree to allow the Community Development Department to duplicate and distribute plans to interested persons as it determines is necessary for the processing of the application. Applicant/Representative Certification: By signing this application I certify that the information provided is accurate. I understand the City might not approve what I’m applying for, or might set conditions of approval. I agree to allow the Community Development Department to duplicate and distribute plans to interested persons as it determines is necessary for processing of the application. Signed Date Signed Date This section is to be completed by the property owner and/or occupant who controls access to the property. To adequately evaluate many project proposals Community Development Department Staff, Commissioners and City Council Members will have to gain access to the exterior of the real property in order to adequately review and report on the proposed project. Your signature below certifies that you agree to give the City permission to access the project site from 8 a.m. to 5 p.m., Monday through Friday, as part of the normal review of this planning application. Occasionally, Community Development Department staff may need access to one or more buildings on the project site. If this is the case, Staff will use the contact information below to arange an appointment. Permission to Access Property:Interior Inspection Contact Information: Signed Date Name: Address: Day Phone: Check Review Application No. Fee Paid Rezoning/PD Use Permit Variance ARC Review Env. Review Subdivision GP Amendment Annexation Other Application fee paid by: the applicant the representative the property owner Received by: Date: Notes to file: Office Use Only6-16 Indemnification Agreement: The Owner/Applicant shall defend, indemnify and hold harmless the City or its agents or officers and employees from any claim, action or proceeding against the City or its agents, officers or employees, to attack, set aside, void, or annul, in whole or in part, the City’s approval of this project. In the event that the City fails to promptly notify the Owner / Applicant of any such claim, action or pro- ceeding, or that the City fails to cooperate fully in the defense of said claim, this condition shall thereafter be of no further force or effect. Signed Date Email: Email: Email: Property Owner Authorization: 619 Grove Street; APN: 001-056-029 SB 9 60/40 Lot Split John Rourke MBS Land Surveys (805) 594-1960 3559 S. Higuera St. kmargason@MBSLandSurveys.com (805) 440-4973 163 Serrano Heights., San Luis Obispo Michael Rourke (805) 748-9330 619 Grove St., San rourkefam@gmail.com John Rourke 163 Serrano Heights, SLO (805) 440-4973 Community Development Department 919 Palm Street, San Luis Obispo, California (805) 781-7170 Completed Planning Application Form: Applications can be obtained from the Community Development Department or by mail, fax, or at: www.slocity.org/government/department-directory/community-development Applications for development permits must include, at minimum, the information in this checklist in order to be accepted for processing and evaluation for final action. Additional information may be required following initial review by staff. Applications missing information in this checklist will not be accepted for review. Preliminary title report. An Authorization consenting to the proposed subdivision signed by all parties having a record title interest in the property to be subdivided (if not included on the planning application form.) Assessor Parcel Map(s) with the property to be subdivided highlighted. Lot lines/Structures. Existing or proposed street and lot lines and the location and outline to scale of all structures which are to be retained within the subdivision and all structures outside the subdivision within 10 feet of the boundary lines; the distances between structures to be retained and notations concerning all structures which are to be removed. Trees. The location, type, trunk and canopy diameter of all trees on the property and indicate status (e.g. to be removed, maintained, or relocated); notations as to general type of vegetation in areas not occupied by trees. Topography. Topographic information based on City datum (reference data source). Contours shall have a minimum interval of two meters. Property boundaries. The boundaries of the subdivision, defined by legal description, with sufficient information to locate the property and to determine its position with respect to adjacent named or numbered subdivisions, if any. Subdivider. Names and addresses of the subdivider and all parties having record title interest in the property being subdivided. Map maker. Name and address of the person or entity who prepared the map and the applicable registration or license number. Map number. The parcel map number (available from County Planning Dept. 781-5600), name if any, date of preparation, North arrow, metric scale, and, if based on a survey, the date of the survey. Easements. The locations, widths and purpose of all existing and proposed easements for utilities, drainage and other public purposes, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, fire sprinkler water lateral, street trees and street lights. Application Checklist Effective: 7-01-2021 Minor Subdivision (4 lots or fewer) Tentative Subdivision Map Application Fee: $7,306.12 Checklist continued on next page. Tentative Parcel Map, at appropriate scale, using U.S. Customary or English Units •9 copies at full size (18” x 26”) •1 copy at reduced size (8.5” x 11”) Drainage. The name, location, width and directions of flow of all watercourses and flood hazard zone areas within and adjacent to the property involved; the proposed method of providing storm water drainage and erosion control. Exceptions. Any exception being requested in accordance with the requirements of Municipal Code - Chapter 16.48 - Subdivision Exceptions shall be clearly labeled and identified as to nature and purpose. Public access. The boundaries, acreage and use of existing and proposed public areas in and adjacent to the subdivision. If land is to be offered for the dedication for park or recreation purposes or for the purpose of providing public access to any public waterway, river or stream, it shall be so designated. Railroad easments. The location of all railroad rights-of-way and grade crossings. Water systems. The locations of any existing or abandoned wells, septic leaching fields, springs, water impound- ments and similar features to the extent they affect the proposed use of the property. Subdivision boundaries. When it is known that separate final maps are to be filed on portions of the property shown on the tentative map, show the subdivision boundaries which will appear on said final maps and note the sequence in which said final maps will be filed. Condominium information. Maps for condominium projects shall indicate the address of the property and the number, size and location of proposed dwelling units, parking spaces, and private or public open spaces. Condo- minium project maps shall comply with the City’s Condominium Development and Conversion Regulations. For all condominium projects, the floor area of each unit shall be shown in proper scale and location together with the plan view of each ownership unit. Also include an open space plan showing “qualifying” private and common areas with square footages of those areas (private open spaces shall be totaled per unit). The following supplemental material shall be filed with the tentative map: A vicinity map of appropriate scale and showing sufficient adjoining territory to clearly indicate surrounding streets, other land in the subdivider’s ownership, and other features with a bearing on the proposed subdivision. A statement of existing and proposed land use. A statement of proposed improvements and landscape modifications, including the estimated time of completion in relation to subdivision of the property. A description of proposed public or commonly held open space easement agreements, if applicable. Draft covenants, conditions and restrictions if they are integral to the development concept or propose atypical requirements. A written description of requested exceptions from the subdivision design standards for such items as lot area and dimensions, street sections or utility easements. Proposed building setback and yards if different from those in the Zoning Regulations. Lot statistics. The lines and approximate dimensions of all lots, and the number assigned to each lot (lots shall be numbered consecutively); the total number of lots; the area of each lot. Streets. The locations, widths and names or designations of all existing or proposed streets, alleys, paths and other rights-of-way, whether public or private; private easements within and adjacent to the subdivision; the radius of each centerline curve; a cross-section of each street and planned line for street widening or for any other public project in and adjacent to the subdivision; private streets shall be clearly indicated. Checklist continued on next page. Water Efficient Landscape Standards Provide the square footage of each Hydrozone area (landscaped areas having plants with similar water needs, served by valves with the same irrigation schedule). Provide a completed Worksheet for Maximum Applied Water Allowance and Estimated Total Water Use calculations Complete online & print, or download Excel worksheet: www.slocity.org/utilities/download/lndscpcalc.xls Minor Subdivision (Tentative Subdivision Map) Page 2 Site Hazards. The location of all potentially dangerous areas, including areas subject to inundation, landslide, settlement, excessive noise, and the means of mitigating the hazards. Tentative Parcel Map (cont...) N/A N/A N/A N/A N/A A soils engineering report, prepared by a civil engineer registered in the State of California and based upon adequate test borings, shall be required for every subdivision, unless the City Engineer determines that no analysis is necessary. If the soils engineering report indicates soil problems, a soils investigation of each lot in the subdivision may be required. The soils engineering report shall include data regarding the nature, distribution and strength of existing soils, conclusions and recommendations for grading procedures and design criteria for corrective measures, when nec- essary, and opinions and recommendations covering the adequacy of sites for development. In potential noise problem areas identified in the General Plan Noise Element, specific site analysis by an acoustical engineer or other approved professional with qualifications in acoustic design may be required by the Community Development Director. Such a study shall define the noise exposure problems, conclusions and recommendations for corrective or mitigating measures, when necessary, and opinions and recommendations covering the suitability of the site for development. Retaining wall locations and heights. Distribution and general nature of rock and soils. A reasonable evaluation and prediction of the performance of any proposed cut or fill in relation to geologic conditions. Capability of soils and substrata to support structures. Recommendations concerning future detailed subsurface sampling and testing that may be required prior to building. Capability of soils and substrata to support structures. Engineering Geology Report. An engineering geology report may be required in areas of “moderate”, “high”, and “very high” landslide risks, and in areas of “high” and “high+” liquefaction and subsidence potential as noted in the General Plan Seismic Safety Element. The engineering geology report shall include definite statements, conclusions and recommendations concerning the following, as applicable: Location of major geologic features. Topography and drainage in the subject areas. Low Impact Development (Stormwater Requirements). Based on increased impervious surface area created by your project, and on the nature of the project (certain site features or intended land uses), your project may be subject to certain Low Impact Development (LID) Measures to reduce stormwater runoff. Preliminary Grading and Drainage Plan. Show existing and proposed contours, finished floor elevations, retaining walls and retaining wall heights, approximate area, depth and volume of cuts and location of fills, creek flow line, flow direction, top of banks, flood zones and areas of flooding in a 100-year storm. Checklist continued on next page. Supplemental Materials (cont...) Water Ways Management Plan Compliance: Detailed analysis of the site will be required for some projects, consistent with Section 2.2, Volume III of the WWMP, the City’s Drainage Design Manual. Drainage analysis submittals shall include adequate supporting hydrologic and hydraulic information for the proposed improvements. The Hydrologic and Hydraulic Analysis Report shall be prepared by a Civil Engineer registered in the State of California. Details of report contents are in Section 2.2 of the Manual. Inclusionary Housing Proposal: Provide a statement indicating how the project will meet its inclusionary housing requirement including plans showing the number, type and location of affordable units to be built or converted and the term of affordability, or a preliminary calculation of in-lieu fees, or an offer of land dedication. Page 3 Stormwater (Stormwater Control Plan for Post Construction Requirements): Complete the Stormwater Control Plan for Post Construction Requirements Checklist available from Community Development, and online on the Engineering Development Review web page (www.slocity.org > Government > Department Directory > Community Development) Minor Subdivision (Tentative Subdivision Map) N/A N/A N/A N/A N/A N/A N/A N/A Vesting Map Application Requirements All vesting tentative map submittals must be accurate and complete, and must satisfy all requirements of the Community Development Department. At the time a vesting tentative map is filed a subdivider shall also supply the following information: A statement that Architectural Review approval has been granted, or a complete application for Architectural Review approval and plans have been filed which will be concurrently processed with the vesting tentative map for all buildings to be constructed on lots within the boundary of the vesting tentative map. A statement that the vesting tentative map is consistent with the current zoning, or that an application has been filed for rezoning or prezoning the land which will be processed concurrently with the vesting tentative map. If a planned development permit, hillside planned development permitor use permit is required, said permit shall be processed prior to or concurrently with the vesting tentative map. A tentative utility plan indicating the location of all public utilities and facilities including, but not limited to, facilities for water, sewer, electric, gas, cable TV and street lighting to be installed to serve the subdivision and any facilities which currently exist within the boundary of the subdivision. Identify the dimensions (in scale) and proposed use of all buildings to be constructed within the subdivision. Proposed grading plans based on actual field surveys. Wild fire prevention plan and/or noise analysis with suggested mitigation measures if required by the City’s General Plan or any specific plan. Required approval letters from other agencies where applicable and feasible. Traffic studies including, but not limited to, existing and future traffic, geometrics, number of lanes, level of service, and recommended pavement sections in compliance with the City’s Traffic Impact Study Guidelines. When required by the Community Development Department, feasibility studies or other future impact studies. Any studies or information deemed necessary by the Director to evaluate environmental and economic impacts of the project. Wild fire prevention plan and/or noise analysis with suggested mitigation measures if required by the City’s General Plan or any specific plan. Page 4 Minor Subdivision (Tentative Subdivision Map) N/A CLTA Preliminary Report Form Order Number: 4009-6870627 (Rev. 11/06) Page Number: 1 First American Title Page 1 of 12 First American Title Company 899 Pacific Street San Luis Obispo, CA 93401 California Department of Insurance License No. 151 Escrow Officer: Denise Simon Phone: (805)786-2018 Fax No.: (866)654-3623 E-Mail: dsimon@firstam.com E-Mail Loan Documents to: Lenders please contact the Escrow Officer for email address for sending loan documents. Buyer: TBD Owner: TBD Property: 619 Grove St San Luis Obispo, CA 93401 PRELIMINARY REPORT In response to the above referenced application for a policy of title insurance, this company hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a Policy or Policies of Title Insurance describing the land and the esta te or interest therein hereinafter set forth, insuring against loss which may be sustained by reason of any defect, lien or encumbrance not shown or referred to as an Exception below or not excluded from coverage pursuant to the printed Schedules, Conditions and Stipulations of said Policy forms. The printed Exceptions and Exclusions from the coverage and Limitations on Covered Risks of said policy or policies are set forth in Exhibit A attached. The policy to be issued may contain an arbitration clause. When the Amount of Insurance is less than that set forth in the arbitration clause, all arbitrable matters shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. Limitations on Covered Risks applicable to the CLTA and ALTA Homeowner's Policies of Title Insurance which establish a Deductible Amount and a Maximum Dollar Limit of Liability for certain coverages are also set forth in Exhibit A. Copies of the policy forms should be read. They are available from the office which issued this report. Please read the exceptions shown or referred to below and the exceptions and exclusions set forth in Exhibit A of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered. It is important to note that this preliminary report is not a written representation as to the condition of title and may not list all liens, defects, and encumbrances affecting title to the land. Please be advised that any provision contained in this document, or in a document that is attached, linked or referenced in this document, that under applicable law illegally discriminates against a class of individuals based upon personal characteristics such as race, color, religion, sex, sexual orientation, gender identity, familial status, disability, national origin, or any other legally protected class, is illegal and unenforceable by law. This report (and any supplements or amendments hereto) is issued solely for the purpose o f facilitating the issuance of a policy of title insurance and no liability is assumed hereby. If it is desired that liability be assumed prior to the issuance of a pol icy of title insurance, a Binder or Commitment should be requested. Order Number: 4009-6870627 Page Number: 2 First American Title Page 2 of 12 Dated as of June 27, 2022 at 7:30 A.M. The form of Policy of title insurance contemplated by this report is: ALTA/CLTA Homeowner's (EAGLE) Policy of Title Insurance (2013) and ALTA Ext Loan Policy 1056.06 (06-17-06) if the land described is an improved residential lot or condominium unit on which there is located a one-to-four family residence; or ALTA Standard Owner's Policy 2006 (WRE 06-17-06) and the ALTA Loan Policy 2006 (06-17-06) if the land described is an unimproved residential lot or condominium unit A specific request should be made if another form or additional coverage is desired. Title to said estate or interest at the date hereof is vested in: Michael Rourke, an unmarried man The estate or interest in the land hereinafter described or referred to covered by this Report is: FEE The Land referred to herein is described as follows: (See attached Legal Description) At the date hereof exceptions to coverage in addition to the printed Exceptions and Exclusions in said policy form would be as follows: 1. General and special taxes and assessments for the fiscal year 2022-2023, a lien not yet due or payable. 2. All taxes - secured, supplemental, defaulted, escaped and including bonds and assessments are not available at this time. Please verify any/all tax amounts and assessment information with the County Tax Collector prior to the close of the contemplated transaction. 3. The lien of supplemental taxes, if any, assessed pursuant to Chapter 3.5 commencing with Section 75 of the California Revenue and Taxation Code. Order Number: 4009-6870627 Page Number: 3 First American Title Page 3 of 12 4. A deed of trust to secure an original indebtedness of $700,000.00 recorded MAY 31, 2022 as INSTRUMENT NO. 22-22975 OF OFFICIAL RECORDS. Dated: MAY 26, 2022 Trustor: MICHAEL ROURKE, AN UNMARRIED MAN Trustee: FIRST AMERICAN TITLE INSURANCE COMPANY, A NEBRASKA CORPORATION Beneficiary: JOHN ROURKE a. If this deed of trust is to be eliminated in the policy or policies contemplated by this report/commitment, the company will require the following for review prior to the recordation of any documents or the issuance of any policy of title insurance: i. Original note and deed of trust. ii. Payoff demand statement signed by all present beneficiaries. iii. Request for reconveyance or substitution of trustee and full reconveyance must be signed by all present beneficiaries and must be notarized by a First American approved notary. b. If the payoff demand statement or the request for reconveyance is to be signed by a servicer, we will also require a full copy of the loan servicing agreement executed by all present beneficiaries. c. If any of the beneficial interest is presently held by trustees under a trust agreement, we will require a certification pursuant to Section 18100.5 of the California Probate Code in a form satisfactory to the Company. 5. The new lender, if any, for this transaction may be a Non-Institutional Lender. If so, the Company will require the Deed of Trust to be signed before a First American approved notary. Order Number: 4009-6870627 Page Number: 4 First American Title Page 4 of 12 INFORMATIONAL NOTES Note: The policy to be issued may contain an arbitration clause. When the Amount of Insurance is less than the certain dollar amount set forth in any applicable arbitration clause, all arbitrable matters shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. If you desire to review the terms of the policy, including any arbitration clause that may be included, contact the office that issued this Commitment or Report to obtain a sample of the policy jacket for the policy that is to be issued in connection with your transaction. 1. This report is preparatory to the issuance of an ALTA Loan Policy. We have no knowledge of any fact which would preclude the issuance of the policy with CLTA endorsement forms 100 and 116 and if applicable, 115 and 116.2 attached. When issued, the CLTA endorsement form 116 or 116.2, if applicable will reference a(n) Single Family Residence known as 619 GROVE STREET, SAN LUIS OBISPO, CA. 2. According to the public records, there has been no conveyance of the land within a period of twenty four months prior to the date of this report, except as follows: A document recorded MAY 31, 2022 as INSTRUMENT NO. 22-22974 OF OFFICIAL RECORDS From: CHARLES G. KIRSCHNER, SUCCESSOR TRUSTEE OF THE DOLORES E. HERZOG REVOCABLE TRUST, U/D/T DATED JANUARY 9, 1998 To: MICHAEL ROURKE, AN UNMARRIED MAN NOTE to proposed insured lender only: No Private transfer fee covenant, as defined in Federal Housing Finance Agency Final Rule 12 CFR Part 1228, that was created and first appears in the Public Records on or after February 8, 2011, encumbers the Title except as follows: None The map attached, if any, may or may not be a survey of the land depicted hereon. First American expressly disclaims any liability for loss or damage which may result from reliance on this map except to the extent coverage for such loss or damage is expressly provided by the terms and provisions of the title insurance policy, if any, to which this map is attached. Order Number: 4009-6870627 Page Number: 5 First American Title Page 5 of 12 LEGAL DESCRIPTION Real property in the City of San Luis Obispo, County of San Luis Obispo, State of California, described as follows: ALL THAT PORTION OF BLOCK 1 OF PHILLIPS' ADDITION TO THE CITY OF SAN LUIS OBISPO, COUNTY OF SAN LUIS OBISPO, STATE OF CALIFORNIA, AS SUBDIVIDED FOR EDWIN GOODALL IN SEPTEMBER, 1887, ACCORDING TO THE MAP FILED IN BOOK A, PAGE 162 OF MAPS RECORDS OF SAID COUNTY, DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHEASTERLY CORNER OF BLOCK 1 AS SAID BLOCK IS SHOWN AND DELINEATED ON SAID MAP; THENCE NORTHERLY ALONG THE WESTERLY LINE OF GROVE STREET, 50 FEET; THENCE WESTERLY AND PARALLEL WITH THE SOUTHERLY LINE OF SAID BLOCK, 120 FEET; THENCE SOUTHERLY AND PARALLEL WITH THE WESTERLY LINE OF GROVE STREET, 50 FEET TO THE SOUTHERLY LINE OF SAID BLOCK; THENCE EASTERLY ALONG THE SOUTHERLY LINE OF SAID BLOCK, 120 FEET TO THE POINT OF BEGINNING AND BEING PART OF LOTS 1, 2 AND 3 IN BLOCK 1, ACCORDING TO THE ABOVE MENTIONED MAP. APN: 001-056-029 Order Number: 4009-6870627 Page Number: 6 First American Title Page 6 of 12 Order Number: 4009-6870627 Page Number: 7 First American Title Page 7 of 12 NOTICE Section 12413.1 of the California Insurance Code, effective January 1, 1990, requires that any title insurance company, underwritten title company, or controlled escrow company handling funds in an escrow or sub- escrow capacity, wait a specified number of days after depositing funds, before recording any documents in connection with the transaction or disbursing funds. This statute allows for funds deposited by wire transfer to be disbursed the same day as deposit. In the case of cashier's checks or certified checks, funds may be disbursed the next day after deposit. In order to avoid unnecessary delays of three to seven days, or more, please use wire transfer, cashier's checks, or certified checks whenever possible. Order Number: 4009-6870627 Page Number: 8 First American Title Page 8 of 12 EXHIBIT A LIST OF PRINTED EXCEPTIONS AND EXCLUSIONS (BY POLICY TYPE) CLTA STANDARD COVERAGE POLICY – 1990 EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason of: 1. (a) Any law, ordinance or governmental regulation (including but not limited to building or zoning laws , ordinances, or regulations) restricting, regulating, prohibiting or relating (i) the occupancy, use, or enjoyment of the land; (ii) the character, dimens ions or location of any improvement now or hereafter erected on the land; (iii) a separation in owner ship or a change in the dimensions or area of the land or any parcel of which the land is or was a part; or (iv) environmental protection, or the eff ect of any violation of these laws, ordinances or governmental regulations, except to the extent that a not ice of the enforcement thereof or a notice of a defect, lien, or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. (b) Any governmental police power not excluded by (a) above, except to the extent that a notice of the exercise thereof or notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. 2. Rights of eminent domain unless notice of the exercise thereof has been recorded in the public records at Date of Policy, but not excluding from coverage any taking which has occurred prior to Date of Policy which would be binding on the rights of a purch aser for value without knowledge. 3. Defects, liens, encumbrances, adverse claims or other matters: (a) whether or not recorded in the public records at Date of Policy, but created, suffered, assumed or agreed to by the insured claimant; (b) not known to the Company, not recorded in the public records at Date of Policy, but known to the insured claimant and not disclosed in writing to the Company by the insured claimant prior to the date the insured claimant became an insured under this policy; (c) resulting in no loss or damage to the insured claimant; (d) attaching or created subsequent to Date of Policy; or (e) resulting in loss or damage which would not have been sustained if the insured claimant had paid value for the insured mortgage or for the estate or interest insured by this policy. 4. Unenforceability of the lien of the insured mortgage because of the inability or failure of the insured at Date of Policy, or the inability or failure of any subsequent owner of the indebtedness, to comply with the applicable doing business laws of the state in which the land is situated. 5. Invalidity or unenforceability of the lien of the insured mortgage, or claim thereof, which arises out of the transaction evi denced by the insured mortgage and is based upon usury or any consumer credit protection or truth in lending law. 6. Any claim, which arises out of the transaction vesting in the insured the estate of interest insured by this policy or the tr ansaction creating the interest of the insured lender, by reason of the operation of federal bankruptcy, state insolvency or similar creditors' rights laws. EXCEPTIONS FROM COVERAGE - SCHEDULE B, PART I This policy does not insure against loss or damage (and the Company will not pay costs, attorneys' fees or expenses) which arise by reason of: 1. Taxes or assessments which are not shown as existing liens by the records of any taxing authority that levies taxes or assess ments on real property or by the public records. Proceedings by a public agency which may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the public, records. 2. Any facts, rights, interests, or claims which are not shown by the public records but which could be ascertain ed by an inspection of the land or which may be asserted by persons in possession thereof. 3. Easements, liens or encumbrances, or claims thereof, not shown by the public records. 4. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, or any other facts which a correct survey would disclose, and which are not shown by the public records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) wate r rights, claims or title to water, whether or not the matters excepted under (a), (b) or (c) are shown by the public records. 6. Any lien or right to a lien for services, labor or material unless such lien is shown by the public records at Date of Policy . CLTA/ALTA HOMEOWNER'S POLICY OF TITLE INSURANCE (12-02-13) EXCLUSIONS In addition to the Exceptions in Schedule B, You are not insured against loss, costs, attorneys' fees, and expenses resulting from: 1. Governmental police power, and the existence or violation of those portions of any law or government regulation concerning: a. building; Order Number: 4009-6870627 Page Number: 9 First American Title Page 9 of 12 b. zoning; c. land use; d. improvements on the Land; e. land division; and f. environmental protection. This Exclusion does not limit the coverage described in Covered Risk 8.a., 14, 15, 16, 18, 19, 20, 23 or 27. 2. The failure of Your existing structures, or any part of them, to be constructed in accordance with applicable building codes. This Exclusion does not limit the coverage described in Covered Risk 14 or 15. 3. The right to take the Land by condemning it. This Exclusion does not limit the coverage described in Covered Risk 17. 4. Risks: a. that are created, allowed, or agreed to by You, whether or not they are recorded in the Public Records; b. that are Known to You at the Policy Date, but not to Us, unless they are recorded in the Public Records at the Policy Dat e; c. that result in no loss to You; or d. that first occur after the Policy Date - this does not limit the coverage described in Covered Risk 7, 8.e., 25, 26, 27 or 28. 5. Failure to pay value for Your Title. 6. Lack of a right: a. to any land outside the area specifically described and referred to in paragraph 3 of Schedule A; and b. in streets, alleys, or waterways that touch the Land. This Exclusion does not limit the coverage described in Covered Risk 11 or 21. 7. The transfer of the Title to You is invalid as a preferential transfer or as a fraudulent transfer or conveyance under federal ban kruptcy, state insolvency, or similar creditors' rights laws. 8. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake, or subsidence. 9. Negligence by a person or an Entity exercising a right to extract or develop minerals, water, or any other substances. LIMITATIONS ON COVERED RISKS Your insurance for the following Covered Risks is limited on the Owner's Coverage Statement as follows: For Covered Risk 16, 18, 19, and 21 Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A. The deductible amounts and maximum dollar limits shown on Schedule A are as follows: Your Deductible Amount Our Maximum Dollar Limit of Liability Covered Risk 16: 1% of Policy Amount Shown in Schedule A or $2,500 $10,000 (whichever is less) Covered Risk 18: 1% of Policy Amount Shown in Schedule A or $5,000 $25,000 (whichever is less) Covered Risk 19: 1% of Policy Amount Shown in Schedule A or $5,000 $25,000 (whichever is less) Covered Risk 21: 1% of Policy Amount Shown in Schedule A or $2,500 $5,000 (whichever is less) 2006 ALTA LOAN POLICY (06-17-06) EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, c osts, attorneys' fees, or expenses that arise by reason of: 1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to (i) the occupancy, use, or enjoyment of the Land; (ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or (iv) environmental protection; or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1(a) does not modify or limit the coverage provided under Covered Risk 5. (b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 6. 2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8. Order Number: 4009-6870627 Page Number: 10 First American Title Page 10 of 12 3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 11, 13, or 14); or (e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Insured Mor tgage. 4. Unenforceability of the lien of the Insured Mortgage because of the inability or failure of an Insured to comply with applicable doing -business laws of the state where the Land is situated. 5. Invalidity or unenforceability in whole or in part of the lien of the Insured Mortgage that arises out of the transaction evidenced by the Insured Mortgage and is based upon usury or any consumer credit protection or truth-in-lending law. 6. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors' rights laws, that the transaction creating the lien of the Insured Mortgage, is (a) a fraudulent conveyance or fraudulent transfer, or (b) a preferential transfer for any reason not stated in Covered Risk 13(b) of this policy. 7. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching between Date of Policy and the date of recording of the Insured Mortgage in the Public Records. This Exclusion does not modify or limit the covera ge provided under Covered Risk 11(b). The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage: EXCEPTIONS FROM COVERAGE [Except as provided in Schedule B - Part II,[ t[or T]his policy does not insure against loss or damage, and the Company will not pay costs, attorneys' fees or expenses, that arise by reason of: [PART I [The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclus ions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage: 1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or ass essments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 2. Any facts, rights, interests, or claims that are not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records. 6. Any lien or right to a lien for services, labor or material unless such lien is shown by the Publ ic Records at Date of Policy. PART II In addition to the matters set forth in Part I of this Schedule, the Title is subject to the following matters, and the Compa ny insures against loss or damage sustained in the event that they are not subordinate to the lien of the Insured Mortgage:] 2006 ALTA OWNER'S POLICY (06-17-06) EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, c osts, attorneys' fees, or expenses that arise by reason of: 1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, reg ulating, prohibiting, or relating to (i) the occupancy, use, or enjoyment of the Land; (ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or (iv) environmental protection; or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1(a) does not modify or limit the coverage provided under Covered Risk 5. Order Number: 4009-6870627 Page Number: 11 First American Title Page 11 of 12 (b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 6. 2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8. 3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Cov ered Risk 9 or 10); or (e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Title. 4. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors' rights laws, that the tr ansaction vesting the Title as shown in Schedule A, is (a) a fraudulent conveyance or fraudulent transfer, or (b) a preferential transfer for any reason not stated in Covered Risk 9 of this policy. 5. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching between Date of Policy and the date of recording of the deed or other instrument of transfer in the Public Records that vests Title as shown in Sche dule A. The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage : EXCEPTIONS FROM COVERAGE This policy does not insure against loss or damage, and the Company will not pay costs, attorneys' fees or expenses, that arise by reason of: [The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclus ions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage: 1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or ass essments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 2. Any facts, rights, interests, or claims that a re not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an ac curate and complete land survey of the Land and not shown by the Public Records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records. 6. Any lien or right to a lien for services, labor or material unless such lien is shown by the Public Records at Date of Policy. 7. [Variable exceptions such as taxes, easements, CC&R's, etc. shown here.] ALTA EXPANDED COVERAGE RESIDENTIAL LOAN POLICY (07-26-10) EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, c osts, attorneys' fees, or expenses that arise by reason of: 1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to (i) the occupancy, use, or enjoyment of the Land; (ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or (iv) environmental protection; or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1(a) does not modify or limit the coverage provided under Covered Risk 5, 6, 13(c), 13(d), 14 or 16. (b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 5, 6 , 13(c), 13(d), 14 or 16. 2. Rights of eminent domain. This Exclusion does not modify or limit the coverage pr ovided under Covered Risk 7 or 8. 3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 11, Order Number: 4009-6870627 Page Number: 12 First American Title Page 12 of 12 16, 17, 18, 19, 20, 21, 22, 23, 24, 27 or 28); or (e) resulting in loss or damage that would not have been sustained i f the Insured Claimant had paid value for the Insured Mortgage. 4. Unenforceability of the lien of the Insured Mortgage because of the inability or failure of an Insured to comply with applica ble doing-business laws of the state where the Land is situated. 5. Invalidity or unenforceability in whole or in part of the lien of the Insured Mortgage that arises out of the transaction evi denced by the Insured Mortgage and is based upon usury or any consumer credit protection or truth-in-lending law. This Exclusion does not modify or limit the coverage provided in Covered Risk 26. 6. Any claim of invalidity, unenforceability or lack of priority of the lien of the Insured Mortgage as to Advances or modificat ions made after the Insured has Knowledge that the vestee shown in Schedule A is no longer the owner of the estate or interest covered by this policy. This Exclusion does not modify or limit the coverage provided in Covered Risk 11. 7. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching subsequent to Date of Policy. This Exclusion does not modify or limit the coverage provided in Covered Risk 11(b) or 25. 8. The failure of the residential structure, or any portion of it, to have been const ructed before, on or after Date of Policy in accordance with applicable building codes. This Exclusion does not modify or limit the coverage provided in Covered Risk 5 or 6. 9. Any claim, by reason of the operation of federal bankruptcy, state insolvency , or similar creditors' rights laws, that the transaction creating the lien of the Insured Mortgage, is (a) a fraudulent conveyance or fraudulent transfer, or (b) a preferential transfer for any reason not stated in Covered Risk 27(b) of this policy. 10. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake, or subsidence. 11. Negligence by a person or an Entity exercising a right to extract or develop minerals, water, or any other substances. SB 9 Urban Lot Split Feasibility Study Checklist Section 66411.7, Government Code Assigned Parcel Map No. SLO 22-0042 PROJECT LOCATION Street Address: 619 Grove City: San Luis Obispo County: San Luis Obispo APN: 001-056-029 Urban Area/Urban Cluster (per Census): Yes No (City boundaries include some portion of urbanized area/urban cluster per U.S. Census?) Zoning: R1-Low Den Combining designations: None Fire Hazard: Low Existing Parcel size (must be at least 2,400 sq. ft.): 6,000 sq.ft./0.13 acres Proposed sizes: Parcel 1: 2,409 sq.ft. (40%) (Parcels must be at least a 40%-60% split) Parcel 2: 3,591 sq.ft. (60%) Existing housing: Owner Occupied? Yes How long? Rental? Yes How long has current tenant lived there? If the current unit is a Rental, is it the subject of an affordable housing agreement or rent control ordinance? Has the owner used the Ellis Act to evict a tenant in the last 15 years? PROJECT DESCRIPTION Describe the project being proposed: SB 9 Urban Lot 40/60 Split Will there be demolition or alteration of existing housing? Was the original parcel created by an SB 9 lot split? No Have adjacent parcels been SB 9 divided by the same owner or someone acting in concert? (Same person/or agent cannot perform a lot split on adjacent lots.) _No Does Client intend to use the Two-Unit building component of SB 9? THE FOLLOWING CRITERIA HAS BEEN MET: Ministerial approval of subdivision when: 1. Creates no more than 2 parcels 2. Parcels approximately equal size, based on 40%/60% split. 2nd parcel is a minimum of 40% the size of parent parcel. 3. Parcels are 1,200 sq. ft. or larger. 4. Parcel within a “single-family residential” zone. 5. Located within a city, where some portion of the city is within urban area or urban cluster. 6. No demolition or alteration of any of the following types of housing: a. Housing subject to “affordable” income rules, regulations, laws, covenants, etc. b. Housing where an owner(s) has used the Ellis Act to evict someone in the last 15 years (eviction because taking house out of rental market) c. Housing occupied by tenant in last 3 years. 7. Parcel not within a. Prime or Important Farmland (defined by Dept. of Ag. Land inventory or designated on Farmland Mapping & Monitoring Program of Dept. of Conservation or preserved by a local ballot measure. b. Wetlands c. Very high fire hazard zone d. Hazardous waste site e. Delineated earthquake fault zone f. Special flood hazard area subject to inundation by 100 year storm as determined by FEMA unless Letter of Map revision or site meets FEMA minimum flood plain management criteria g. Conservation area h. Habitat preservation area i. Under conservation easement AFFIDAVIT OF INTENT TO OCCUPY I, Michael Rouke, applied for an SB 9 Urban Lot Split on my property at 619 Grove Street, under Parcel Map No. SLO 22-0042, in the City of San Luis Obispo, County of San Luis Obispo, State of California. Now, therefore, pursuant to California Government Code Sections 66411.7(g)(1) and 66411.7(h), I affirm under penalty of perjury that I intend to live in one of the dwelling units on the property for three (3) years, beginning on the date of final approval of Parcel Map No. SLO 22-0042. I further affirm that if any unit is rented on either parcel, the rental term will be for a period of 30 days or longer. ______________________________ Date: ___________________________ Michael Rourke STATE OF CALIFORNIA COUNTY OF SAN LUIS OBISPO On __________________, before me, _________________________, a Notary Public, personally appeared __________________________________, who proved to me on the basis of satisfactory evidence to be the persons whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that by their signatures on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. _________________________________________ Notary Public Signature Notary Public Seal A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. GROVE STREETPARCEL 1PARCEL 2WILSON STREETTOPOGRAPHIC MAPPARK STREET SBDV-0458-2022– Completeness Review #4 5/11/2023 Page 1 5/11/2023 Sent via Email John Rourke 163 Serrano Heights San Luis Obispo, CA, 93405 Kerry Margason 3559 South Higuera Street San Luis Obispo, CA, 93401 Subject: Incomplete Letter #4: SBDV-0458-2022 (619 Grove): [Proposed minor subdivision under Senate Bill 9 at 619 Grove Street] Dear Mr. Rourke: Thank you for the April 13, 2023, submittal for the 619 Grove Street minor subdivision project. We have reviewed your application and found it to be incomplete. We will be unable to process your application until additional information and/or revisions have been submitted to the satisfaction of the Community Development Director. Preliminary review is necessary to ensure that staff has adequate information to evaluate your project and identify any conflicts with City standards or guidelines. The purpose of this letter is to provide you with a list of items that need to be addressed prior to taking action on your project. Preliminary review indicates that your application will remain in an incomplete status until the following information and/or revisions are submitted: Note: Upon resubmittal please provide a narrative indicating where responses to these items can be found on plans. Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of- SBDV-0458-2022– Completeness Review #4 5/11/2023 Page 2 way. a. Revise plans to show compliant access to public right-of-way. Comment Remains. Comment Remains. Understood that the project proposal contains access to public right of way via access easement. Please refer to comment 8 to provide an accessway that complies with the objective subdivision standards. Substandard accessways shall only be approved by the Public Works Director. 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. Comment Remains. Comment Remains. Please refer to engineering comments to provide compliant parking or remove parking from your proposal. 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). OK. 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. OK. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. OK. 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. OK. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. OK. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. Comment Remains. Please provide a statement stating how the project cannot satisfy applicable standards. Please specifically identify the objective standard that physically precludes the project from providing a 20’ access easement or access way and why the project is unable to comply. The proposed exception is only required because there are no feasible design options which could allow for site development of two minimum 800 square foot units on either of the two resulting parcels. For the purpose of this finding, existing improvements or development is not considered a physical constraint. Comment Remains, in accordance with Senate Bill 9, Section 2, 3. D., the parcel being subdivided shall not result in any alterations of the existing residence (that was rented out in the last 3 years), if the substandard accessway results in an adverse impact as determined by the Engineering Division or Fire Marshal, then the proposed parcel map shall not qualify under SB 9. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. Understood that this is not a Flag Lot Subdivision. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with SBDV-0458-2022– Completeness Review #4 5/11/2023 Page 3 all application requirements and objective standards identified in Chapter 16.17. Understood that this is not a Common Interest Subdivision. Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General Subdivision Design Standards) and revise plans as appropriate. • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. Comment remains as a note. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). Comment remains as a note. • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. Comment remains as a note. If you have any questions on the above planning comments, or any questions regarding this letter, please contact me at 805-781-7576, or by e-mail at: ogoode@slocity.org Engineering Division – Public Works/Community Development Department 11. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. OK. 12. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) Comment remains. 4th Review: Show existing telecommunications and electrical utility access for Parcel 2. Comment remains. Proposed utility access for Parcel 1 should not state ADU assuming this is a proposed primary residence. Please contact engineering prior to resubmittal to confirm corrections. NOTE: New electrical may require underground instead of overhead lines. 13. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. OK. 14. Provide any shared easements for parking, access, driveway, structural integrity (retaining wall, etc), drainage (blanket drainage easement appears to have parcel numbers reversed), irrigation, etc. Comment remains. 4th Review: Blanket drainage easement parcel numbers still shown as reversed. Comment remains. Please contact engineering prior to resubmittal to confirm corrections. Easement was not corrected it was just removed. SBDV-0458-2022– Completeness Review #4 5/11/2023 Page 4 15. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. Comment remains. 4th Review: Provide justification for how proposed parking spot can be accessed from approach. As shown, it is unclear how vehicles can access this spot (turning radius, etc.). Demonstrate compliance with the City’s parking and driveway standards. Comment remains. Remove parking space if you are pursuing car share or provide details for vehicle maneuverability in accordance with the City’s parking and driveway standards for how the proposed parking spot can be accessed from approach. 16. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. OK 17. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. Driveway shown as 7.65 feet. Comment remains. 4th Review: SB9 standards do not prescribe the alternative of a 6-foot access easement and car share in lieu of objective driveway requirement. Please show compliance with driveway width or approved alternative to the satisfaction of the fire, building, and planning divisions. Comment remains to the satisfaction of the Fire Marshal. 18. Verify if “existing out building” is a permitted structure and is to remain. If you have questions on the above items, please contact Senior Civil Engineer, Charles Weir, (805) 783- 7704, or by e-mail: cweir@slocity.org Building and Safety Division - Community Development Department 19. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. OK. 20. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] OK. 21. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] OK. If you have questions on the above items, please contact Ivan Ramirez, 805-783-7853, or by e-mail: SBDV-0458-2022– Completeness Review #4 5/11/2023 Page 5 iramirez@slocity.org. Utilities Department 22. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. OK. Additional comments not considered completeness comments: • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. If you have questions on the above items, please contact Utilities Program Manager, Shawna Scott, 805- 781-7176, or by e-mail: sscott@slocity.org Fire Department 23. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. OK. 24. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. The Fire Marshal has significant safety concerns regarding the occupants of the land-locked parcel being able to safely egress to the public way considering the tight passage along the existing residence on a parcel the occupants of the rear property have no control over, does not have fire sprinklers and heat exposure from a structure fire would pose an SBDV-0458-2022– Completeness Review #4 5/11/2023 Page 6 eminent risk to those escaping to the public way and a reasonable size area of refuge is non-existent. For safety reasons, the fire department can’t support the application as submitted unless the applicant provides a map that conforms to the City’s lot frontage requirements that provides both egress and fire department access to the rear parcel. Comment Remains. [California Residential Code 311.1 Means of Egress, California Fire Code 1028.5 Access to a Public Way, California Fire Code 504.1] Comment Remains. The plans show a 6-foot-wide access, utility and driveway easement on the parcel 2 south property line in favor of parcel 1. As both an access easement and driveway easement it will be rendered unusable for egress from the residence on parcel 1 should a vehicle use the driveway for parking. In addition, it appears that the path of egress from the residence on parcel 1 accesses the public way through the north side of the residence on parcel 2. There is no indicated egress easement shown that would make this legal. Response (Include Sheet and Detail Number): If you have questions on the above items, please contact Fire Marshal, Rodger Maggio, 805-781-7386, or by e- mail: rmaggio@slocity.org The above list includes all of the items initially identified as necessary for us to certify your application as complete. The City may ask for additional information upon more detailed review of your project. If you have any questions regarding this lette r or the specific items necessary to submit for a complete application, please contact me at (805) 781-7576. Sincerely, Owen Goode CDD Assistant Planner 1/10/2023 Sent via Email John Rourke 163 Serrano Heights San Luis Obispo, CA, 93405 Kerry Margason 3559 South Higuera Street San Luis Obispo, CA, 93401 Subject: Incomplete Letter #2: SBDV-0458-2022 (619 Grove): [Proposed minor subdivision resulting in a flag lot at 619 Grove Street] Dear Mr. Rourke: Thank you for the December 13, 2022, submittal for the 619 Grove Street minor subdivision project. We have reviewed your application and found it to be incomplete. We will be unable to process your application until additional information and/or revisions have been submitted to the satisfaction of the Community Development Director. Preliminary review is necessary to ensure that staff has adequate information to evaluate your project and identify any conflicts with City standards or guidelines. The purpose of this letter is to provide you with a list of items that need to be addressed prior to taking action on your project. Preliminary review indicates that your application will remain in an incomplete status until the following information and/or revisions are submitted: Note: Upon resubmittal please provide a narrative indicating where responses to these items can be found on plans. Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of-way. a. Revise plans to show compliant access to public right-of-way. Please clarify how the project will comply with the access to public right of way requirements under Senate Bill 9. Comment Remains. 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. Comment Remains. . SBDV-0458-2022– Completeness Review #2 1/10/2023 Page 2 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). OK. 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. OK. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. OK. 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. OK. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. OK. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. Comment Remains. Please provide a statement stating how the project cannot satisfy applicable standards of Table 3. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. Comment Remains as a note until access to the right of way is shown. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with all application requirements and objective standards identified in Chapter 16.17. Comment Remains as a note until access to the right of way is shown. Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General Subdivision Design Standards) and revise plans as appropriate. • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. Comment remains as a note. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). Comment remains as a note. • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. Comment remains as a note. If you have any questions on the above planning comments, or any questions regarding this letter, please contact me at 805-781-7576, or by e-mail at: ogoode@slocity.org Engineering Division – Public Works/Community Development Department 11. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. OK. 12. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) Comment remains 13. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. Comment remains 14. Provide any shared easements for parking, access, driveway, structural integrity SBDV-0458-2022– Completeness Review #2 1/10/2023 Page 3 (retaining wall, etc), drainage (blanket drainage easement appears to have parcel numbers reversed), irrigation, etc. Comment remains. 15. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. Comment remains 16. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. OK 17. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. Driveway shown as 7.65 feet. Comment remains. 18. Verify if “existing out building” is a permitted structure and is to remain. If you have questions on the above items, please contact Senior Civil Engineer, Charles Weir, (805) 783-7704, or by e-mail: cweir@slocity.org Building and Safety Division - Community Development Department 19. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. OK. Response (Include Sheet and Detail Number): 20. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] OK. Response (Include Sheet and Detail Number): 21. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] OK. Response (Include Sheet and Detail Number): If you have questions on the above items, please contact Ivan Ramirez, 805-783-7853, or by e-mail: iramirez@slocity.org. Utilities Department 22. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. OK. Additional comments not considered completeness comments: • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. SBDV-0458-2022– Completeness Review #2 1/10/2023 Page 4 • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. If you have questions on the above items, please contact Utilities Program Manager, Shawna Scott, 805-781-7176, or by e-mail: sscott@slocity.org Fire Department 23. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. OK. Response (Include Sheet and Detail Number): 24. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. Comment Remains. Response (Include Sheet and Detail Number): If you have questions on the above items, please contact Fire Marshal, Rodger Maggio, 805-781-7386, or by e- mail: rmaggio@slocity.org The above list includes all of the items initially identified as necessary for us to certify your application as complete. The City may ask for additional information upon more detailed review of your project. If you have any questions regarding this letter or the specific items necessary to submit for a complete application, please contact me at (805) 781-7576. Sincerely, Owen Goode CDD Assistant Planner SBDV-0458-2022– Completeness Review #3 3/9/2023 Page 1 3/9/2023 Sent via Email John Rourke 163 Serrano Heights San Luis Obispo, CA, 93405 Kerry Margason 3559 South Higuera Street San Luis Obispo, CA, 93401 Subject: Incomplete Letter #3: SBDV-0458-2022 (619 Grove): [Proposed minor subdivision under Senate Bill 9 at 619 Grove Street] Dear Mr. Rourke: Thank you for the February 9, 2022, submittal for the 619 Grove Street minor subdivision project. We have reviewed your application and found it to be incomplete. We will be unable to process your application until additional information and/or revisions have been submitted to the satisfaction of the Community Development Director. Preliminary review is necessary to ensure that staff has adequate information to evaluate your project and identify any conflicts with City standards or guidelines. The purpose of this letter is to provide you with a list of items that need to be addressed prior to taking action on your project. Preliminary review indicates that your application will remain in an incomplete status until the following information and/or revisions are submitted: Note: Upon resubmittal please provide a narrative indicating where responses to these items can be found on plans. Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of- SBDV-0458-2022– Completeness Review #3 3/9/2023 Page 2 way. a. Revise plans to show compliant access to public right-of-way. Understood that the project proposal contains access to public right of way via access easement. Please refer to comment 8 to provide an accessway that complies with the objective subdivision standards. Substandard accessways shall only be approved by the Public Works Director. 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. Comment Remains. Please refer to engineering comments to provide compliant parking. 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). OK. 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. OK. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. OK. 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. OK. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. OK. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. Comment Remains. Please provide a statement stating how the project cannot satisfy applicable standards. Please specifically identify the objective standard that physically precludes the project from providing a 20’ access easement or access way and why the project is unable to comply. The proposed exception is only required because there are no feasible design options which could allow for site development of two minimum 800 square foot units on either of the two resulting parcels. For the purpose of this finding, existing improvements or development is not considered a physical constraint. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. Understood that this is not a Flag Lot Subdivision. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with all application requirements and objective standards identified in Chapter 16.17. Understood that this is not a Common Interest Subdivision. Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General SBDV-0458-2022– Completeness Review #3 3/9/2023 Page 3 Subdivision Design Standards) and revise plans as appropriate. • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. Comment remains as a note. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). Comment remains as a note. • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. Comment remains as a note. If you have any questions on the above planning comments, or any questions regarding this letter, please contact me at 805-781-7576, or by e-mail at: ogoode@slocity.org Engineering Division – Public Works/Community Development Department 11. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. OK. 12. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) Comment remains. 3rd Review: Show existing telecommunications and electrical utility access for Parcel 2. Comment remains. Proposed utility access for Parcel 1 should not state ADU assuming this is a proposed primary residence. Please contact engineering prior to resubmittal to confirm corrections. NOTE: New electrical may require underground instead of overhead lines. 13. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. OK. 14. Provide any shared easements for parking, access, driveway, structural integrity (retaining wall, etc), drainage (blanket drainage easement appears to have parcel numbers reversed), irrigation, etc. Comment remains. 3rd Review: Blanket drainage easement parcel numbers still shown as reversed. Comment remains. Please contact engineering prior to resubmittal to confirm corrections. 15. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. Comment remains. 3rd Review: Provide justification for how proposed parking spot can be accessed from approach. As shown, it is unclear how vehicles can access this SBDV-0458-2022– Completeness Review #3 3/9/2023 Page 4 spot (turning radius, etc.). Demonstrate compliance with the City’s parking and driveway standards. Comment remains. 16. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. OK 17. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. Driveway shown as 7.65 feet. Comment remains. 3rd Review: SB9 standards do not prescribe the alternative of a 6-foot access easement and car share in lieu of objective driveway requirement. Please show compliance with driveway width or approved alternative to the satisfaction of the fire, building, and planning divisions. Comment remains. 18. Verify if “existing out building” is a permitted structure and is to remain. If you have questions on the above items, please contact Senior Civil Engineer, Charles Weir, (805) 783- 7704, or by e-mail: cweir@slocity.org Building and Safety Division - Community Development Department 19. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. OK. 20. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] OK. 21. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] OK. If you have questions on the above items, please contact Ivan Ramirez, 805-783-7853, or by e-mail: iramirez@slocity.org. Utilities Department 22. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. OK. SBDV-0458-2022– Completeness Review #3 3/9/2023 Page 5 Additional comments not considered completeness comments: • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. If you have questions on the above items, please contact Utilities Program Manager, Shawna Scott, 805- 781-7176, or by e-mail: sscott@slocity.org Fire Department 23. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. OK. Response (Include Sheet and Detail Number): 24. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. The Fire Marshal has significant safety concerns regarding the occupants of the land - locked parcel being able to safely egress to the public way considering the tight passage along the existing residence on a parcel the occupants of the rear property have no control over, does not have fire sprinklers and heat exposure from a structure fire would pose an eminent risk to those escaping to the public way and a reasonable size area of refuge is non-existent. For safety reasons, the fire department can’t support the application as submitted unless the applicant provides a map that conforms to the City’s lot frontage requirements that provides both egress and fire department access to the rear parcel. Comment Remains. [California Residential Code 311.1 Means of Egress, California Fire Code 1028.5 Access to a Public Way, California Fire Code 504.1] Response (Include Sheet and Detail Number): SBDV-0458-2022– Completeness Review #3 3/9/2023 Page 6 If you have questions on the above items, please contact Fire Marshal, Rodger Maggio, 805-781-7386, or by e- mail: rmaggio@slocity.org The above list includes all of the items initially identified as necessary for us to certify your application as complete. The City may ask for additional information upon more detailed review of your project. If you have any questions regarding this letter or the specific items necessary to submit for a complete application, please contact me at (805) 781-7576. Sincerely, Owen Goode CDD Assistant Planner 9/22/2022 Sent via Email John Rourke 163 Serrano Heights San Luis Obispo, CA, 93405 Kerry Margason 3559 South Higuera Street San Luis Obispo, CA, 93401 Subject: Incomplete Letter #1: SBDV-0458-2022 (619 Grove): [Proposed minor subdivision resulting in a flag lot at 619 Grove Street] Dear Mr. Rourke: Thank you for the August 23, 2022, submittal for the 619 Grove Street minor subdivision project. We have reviewed your application and found it to be incomplete. We will be unable to process your application until additional information and/or revisions have been submitted to the satisfaction of the Community Development Director. Preliminary review is necessary to ensure that staff has adequate information to evaluate your project and identify any conflicts with City standards or guidelines. The purpose of this letter is to provide you with a list of items that need to be addressed prior to taking action on your project. Preliminary review indicates that your application will remain in an incomplete status until the following information and/or revisions are submitted: Note: Upon resubmittal please provide a narrative indicating where responses to these items can be found on plans. Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of-way. a. Revise plans to show compliant access to public right-of-way. 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. [insert app and/or project number] – Completeness Review #1 [date] Page 2 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with all application requirements and objective standards identified in Chapter 16.17. Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General Subdivision Design Standards) and revise plans as appropriate. • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. If you have any questions on the above planning comments, or any questions regarding this letter, please contact me at 805-781-7576, or by e-mail at: ogoode@slocity.org Engineering Division – Public Works/Community Development Department 11. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. 12. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) 13. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. 14. Provide any shared easements for parking, access, driveway, structural integrity (retaining wall, etc), drainage, irrigation, etc. [insert app and/or project number] – Completeness Review #1 [date] Page 3 15. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. 16. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. 17. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. 18. Verify if “existing out building” is a permitted structure and is to remain. If you have questions on the above items, please contact Senior Civil Engineer, Charles Weir, (805) 783-7704, or by e-mail: cweir@slocity.org Building and Safety Division - Community Development Department 19. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. Response (Include Sheet and Detail Number): 20. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Pleas e include the California license number, seal, date of license expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] Response (Include Sheet and Detail Number): 21. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] Response (Include Sheet and Detail Number): If you have questions on the above items, please contact Ivan Ramirez, 805-783-7853, or by e-mail: iramirez@slocity.org. Utilities Department 22. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. Additional comments not considered completeness comments: • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. [insert app and/or project number] – Completeness Review #1 [date] Page 4 • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. If you have questions on the above items, please contact Utilities Program Manager, Shawna Scott, 805-781-7176, or by e-mail: sscott@slocity.org Fire Department 23. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. Response (Include Sheet and Detail Number): 24. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. Response (Include Sheet and Detail Number): If you have questions on the above items, please contact Fire Marshal, Rodger Maggio, 805-781-7386, or by e- mail: rmaggio@slocity.org The above list includes all of the items initially identified as necessary for us to certify your application as complete. The City may ask for additional information upon more detailed review of your project. If you have any questions regarding this letter or the specific items necessary to submit for a complete application, please contact me at (805) 781-7576. Sincerely, Owen Goode CDD Assistant Planner GROVE STREETPARCEL 1PARCEL 2WILSON STREETSLO 22-0042PARK STREET TENTATIVE PARCEL MAP GROVE STREETPARCEL 1PARCEL 2WILSON STREETSLO 22-0042PARK STREET TENTATIVE PARCEL MAP GROVE STREETPARCEL 1PARCEL 2WILSON STREETSLO 22-0042PARK STREET TENTATIVE PARCEL MAP SBDV-0458-2022– Completeness Review #5 10/17/2023 Page 1 10/17/2023 Sent via Email John Rourke 163 Serrano Heights San Luis Obispo, CA, 93405 Kerry Margason 3559 South Higuera Street San Luis Obispo, CA, 93401 Subject: Incomplete Letter #5: SBDV-0458-2022 (619 Grove): [Proposed minor subdivision under Senate Bill 9 at 619 Grove Street] Dear Mr. Rourke: Thank you for the September 18, 2023, submittal for the 619 Grove Street minor subdivision project. We have reviewed your application and found it to be incomplete. We will be unable to process your application until additional information and/or revisions have been submitted to the satisfaction of the Community Development Director. Preliminary review is necessary to ensure that staff has adequate information to evaluate your project and identify any conflicts with City standards or guidelines. The purpose of this letter is to provide you with a list of items that need to be addressed prior to taking action on your project. Preliminary review indicates that your application will remain in an incomplete status until the following information and/or revisions are submitted: Note: Upon resubmittal please provide a narrative indicating where responses to these items can be found on plans. Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of- SBDV-0458-2022– Completeness Review #5 10/17/2023 Page 2 way. a. Revise plans to show compliant access to public right-of-way. Comment Remains. Comment Remains. Understood that the project proposal contains access to public right of way via access easement. Please refer to comment 8 to provide an accessway that complies with the objective subdivision standards. Substandard accessways shall only be approved by the Public Works Director. 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. Comment Remains. Comment Remains. Please refer to engineering comments to provide compliant parking or remove parking from your proposal. OK. 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). OK. 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. OK. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. OK. 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. OK. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. OK. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. Comment Remains. Please provide a statement stating how the project cannot satisfy applicable standards. Please specifically identify the objective standard that physically precludes the project from providing a 20’ access easement or access way and why the project is unable to comply. The proposed exception is only required because there are no feasible design options which could allow for site development of two minimum 800 square foot units on either of the two resulting parcels. For the purpose of this finding, existing improvements or development is not considered a physical constraint. Comment Remains, in accordance with Senate Bill 9, Section 2, 3. D., the parcel being subdivided shall not result in any alterations of the existing residence (that was rented out in the last 3 years), if the substandard accessway results in an adverse impact as determined by the Engineering Division or Fire Marshal, then the proposed parcel map shall not qualify under SB 9. OK. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. Understood that this is not a Flag Lot Subdivision. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with SBDV-0458-2022– Completeness Review #5 10/17/2023 Page 3 all application requirements and objective standards identified in Chapter 16.17. Understood that this is not a Common Interest Subdivision. 11. New Comment. Per Municipal Code 16.15.020 I. 2., draft easement agreements shall be submitted with the subdivision application. Please provide the draft easement agreements to be recorded on both parcels. 12. New Comment. Please complete updated owner occupancy affidavit. Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General Subdivision Design Standards) and revise plans as appropriate. • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. Comment remains as a note. Please contact planning staff regarding a request to this exception. Exceptions must meet the findings under Section 16.15.030 Exceptions to objective standards. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). Comment remains as a note. • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. Comment remains as a note. If you have any questions on the above planning comments, or any questions regarding this letter, please contact me at 805-781-7576, or by e-mail at: ogoode@slocity.org Engineering Division – Public Works/Community Development Department 13. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. OK. 14. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) Comment remains. 4th Review: Show existing telecommunications and electrical utility access for Parcel 2. Comment remains. Proposed utility access for Parcel 1 should not state ADU assuming this is a proposed primary residence. Please contact engineering prior to resubmittal to confirm corrections. NOTE: New electrical may require underground instead of overhead lines. OK. 15. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. OK. SBDV-0458-2022– Completeness Review #5 10/17/2023 Page 4 16. Provide any shared easements for parking, access, driveway, structural integrity (retaining wall, etc), drainage (blanket drainage easement appears to have parcel numbers reversed), irrigation, etc. Comment remains. 4th Review: Blanket drainage easement parcel numbers still shown as reversed. Comment remains. Please contact engineering prior to resubmittal to confirm corrections. Easement was not corrected it was just removed. OK. 17. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. Comment remains. 4th Review: Provide justification for how proposed parking spot can be accessed from approach. As shown, it is unclear how vehicles can access this spot (turning radius, etc.). Demonstrate compliance with the City’s parking and driveway standards. Comment remains. Remove parking space if you are pursuing car share or provide details for vehicle maneuverability in accordance with the City’s parking and driveway standards for how the proposed parking spot can be accessed from approach. OK. 18. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. OK 19. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. Driveway shown as 7.65 feet. Comment remains. 4th Review: SB9 standards do not prescribe the alternative of a 6-foot access easement and car share in lieu of objective driveway requirement. Please show compliance with driveway width or approved alternative to the satisfaction of the fire, building, and planning divisions. Comment remains to the satisfaction of the Fire Marshal. OK. 20. Verify if “existing out building” is a permitted structure and is to remain. If you have questions on the above items, please contact Senior Civil Engineer, Charles Weir, (805) 783- 7704, or by e-mail: cweir@slocity.org Building and Safety Division - Community Development Department 21. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. OK. 22. All sheets of the plans and the first sheet of the calculations are required to be signed by SBDV-0458-2022– Completeness Review #5 10/17/2023 Page 5 the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] OK. 23. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] OK. If you have questions on the above items, please contact Ivan Ramirez, 805-783-7853, or by e-mail: iramirez@slocity.org. Utilities Department 24. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. OK. Additional comments not considered completeness comments: • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. If you have questions on the above items, please contact Utilities Program Manager, Shawna Scott, 805- 781-7176, or by e-mail: sscott@slocity.org Fire Department 25. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. OK. SBDV-0458-2022– Completeness Review #5 10/17/2023 Page 6 26. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. The Fire Marshal has significant safety concerns regarding the occupants of the land-locked parcel being able to safely egress to the public way considering the tight passage along the existing residence on a parcel the occupants of the rear property have no control over, does not have fire sprinklers and heat exposure from a structure fire would pose an eminent risk to those escaping to the public way and a reasonable size area of refuge is non-existent. For safety reasons, the fire department can’t support the application as submitted unless the applicant provides a map that conforms to the City’s lot frontage requirements that provides both egress and fire department access to the rear parcel. Comment Remains. [California Residential Code 311.1 Means of Egress, California Fire Code 1028.5 Access to a Public Way, California Fire Code 504.1] Comment Remains. The plans show a 6-foot-wide access, utility and driveway easement on the parcel 2 south property line in favor of parcel 1. As both an access easement and driveway easement it will be rendered unusable for egress from the residence on parcel 1 should a vehicle use the driveway for parking. In addition, it appears that the path of egress from the residence on parcel 1 accesses the public way through the north side of the residence on parcel 2. There is no indicated egress easement shown that would make this legal. OK. Response (Include Sheet and Detail Number): If you have questions on the above items, please contact Fire Marshal, Rodger Maggio, 805-781-7386, or by e- mail: rmaggio@slocity.org The above list includes all of the items initially identified as necessary for us to certify your application as complete. The City may ask for additional information upon more detailed review of your project. If you have any questions regarding this lette r or the specific items necessary to submit for a complete application, please contact me at (805) 781-7576. Sincerely, Owen Goode CDD Assistant Planner November 6, 2023 John Rourke 163 Serrano Heights San Luis Obispo, CA 93405 SUBJECT: SBDV-0458-2022 – Conformity Review (619 Grove Street, San Luis Obispo CA, 93401) Dear John Rourke: On October 17, 2023, I reviewed your request to pursue a subdivision of a 6,000 square foot R-1 lot as allowed under Senate Bill 9 for conformance with applicable City standards. The proposed subdivision is consistent with applicable City standards but does not meet the required Lot dimensions of Municipal Code Chapter 16.18.030 Table 3. It is identified that under Senate Bill 9, this objective standard (Table 3. Minimum Lot Area and Dimensions) would physically preclude the subdivision from being processed and therefore will not be required. It has also been identified that this lot does not satisfy lot frontage requirements under 16.18.030 Table 3, but a justification statement has been provided stating that a vehicle access easement is not required due to the car share agreement provided and that the subdivision will provide a 10-foot pedestrian access easement as required under Municipal Code Section 16.15.025 B. 2. Prior to final map recordation the applicant will submit a car share agreement for recordation on the property in-lieu of providing any required on-site vehicle parking spaces. It has been determined that the proposed subdivision is eligible for the lot split under Government Code Section 66411.7 and Senate Bill 9 based on the findings below. An application for a Parcel Map can now be submitted to the Engineering Division. 1. The subject property is zoned R-1. 2. The proposed project is not located within areas defined in subparagraphs (B) to (K), inclusive, of paragraph (6) of subdivision (a) of California Government Code §65913.4, which includes: a. Very High Fire Hazard Severity Zone b. Earthquake Fault Zone c. Special Flood Hazard Area d. Regulatory Floodway 3. The subject property is not located within a historic district, identified in the State Historic Resources Inventory, or designated by the City as a historic resource. 4. The proposed project will not require the demolition, or alteration, of any of the following: a. Housing restricted for moderate, low, or very-low income households. SBDV-0528-2022 247 Warren Way Page 2 b. Housing subject to rent or price control c. Housing that was withdrawn from the rental market in the last 15 years (per Section 12.75 of Division 7 of Title 1 of the Government Code) d. Housing occupied by a tenant in the last three (3) years. 5. Properties that contained a rental unit within the last three (3) years, will not demolish 25% or more of the existing exterior structural walls. 6. The proposed project will not be rented for periods of less than thirty (30) consecutive days at a time. 7. The project will provide at least one (1) off-street parking space per unit or complete a car share agreement to qualify for a parking exception. 8. The lot split will result in no more than two (2) lots of at least 1,200 square feet per lot. 9. The resulting lots will be at least 40% of the size of the existing lot. 10. The property has not previously been split through an SB9 Urban Lot Split. 11. The resulting lot split will contain two (2) housing units or less, on each property, including ADUs or JADUs. 12. The individual property owner will occupy one of the housing units as a result of the lot split as their primary residence for a minimum of three (3) years after the approval date. 13. Applicant has read, signed, and submitted the 3-year owner occupancy affidavit. 14. The urban lot split conforms to all objective standards of the Subdivision Map Act. If you have any questions regarding this letter, or if you need additional information about identified requirements, please contact Matt Lafreniere at mlafreni@slocity.org, or Owen Goode at ogoode@slocity.org. Sincerely, Owen Goode Assistant Planner Community Development Michael B Stanton, PLS 5702 Ofc: 805.594.1960 3559 S. Higuera Street Cell: 805.440.4215 San Luis Obispo, Ca 93401 Fax: 805.594.1966 December 12, 2022 Hand Delivered to 919 Palm Street Owen Goode CDD Assistant Planner 919 Palm Street San Luis Obispo, CA 93405 Subject: Response to Incomplete Letter #1: SBDV-0458-2022 (619 Grove) Minor Subdivision (MBS 22-187) Dear Mr. Goode: Following is our response to the incomplete letter for the above project. I have copied your letter and will respond directly under each item in red type. Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of-way. This is a misquote and a misinterpretation of Section 66411.7(c) which it says: “Except as provided in paragraph (2), notwithstanding any local law, a local agency may impose objective zoning standards, objective subdivision standards, and objective design review standards applicable to a parcel created by an urban lot split that do not conflict with this section.(2) A local agency shall not impose objective zoning standards, objective subdivision standards, and objective design review standards that would have the effect of physically precluding the construction of two units on either of the resulting parcels or that would result in a unit size of less than 800 square feet.” It does not say “shall comply” it says you “may impose”. But it also says you shall not impose objective standards that physically preclude construction of 2 units on either parcel. 2 of 6 Imposing a flag driveway with a minimum 20 foot width would preclude the ability to construct 2 units on either parcel. SB9 also states: (e) In addition to any conditions established in accordance with this section, a local agency may require any of the following conditions when considering an application for a parcel map for an urban lot split: (1) Easements required for the provision of public services and facilities. (2) A requirement that the parcels have access to, provide access to, or adjoin the public right-of-way. You may require one parcel to provide access to the other but you may not preclude the parcel based on street frontage because it would preclude the construction of 2 units on either parcel. 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. Parking will be directly behind the existing home. Garage will be removed to provide access to rear parcel. 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). SB 9 Section 66411.7(c)(3)(A) does not require setbacks for an existing structure or a structure constructed in the same location and to the same dimensions as an existing structure. So setbacks are not required here. 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. Easements shall be recorded with the final map. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. Please be specific, which signatures are missing? Who’s signature are we missing? 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. Please provide the code that says a drainage study is required for an urban lot split. I’m 3 of 6 assuming there can be an easement for drainage. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. Improvements and modifications will be proposed with future building plans. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. We cannot meet city standards because there is no way to provide a 20ft frontage for the back parcel, luckily SB9 does not require street frontage, only access. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. The project is not proposed as a flag lot subdivision. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with all application requirements and objective standards identified in Chapter 16.17. SB9 allows for subdivision with access rather than frontage or common interest. For it to be considered common interest the common area is owned either by the association or in common by the owners of the separate interests who possess appurtenant rights to the beneficial use and enjoyment of the common area. In this case there is not a common interest, just easements in favor of the rear parcel. Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General Subdivision Design Standards) and revise plans as appropriate. • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. SB 9 does not require lot frontage. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). • SB 9 does not require lot frontage. • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. • SB 9 does not require a flag lot or the 20 foot minimum lot frontage. SB 9 regulations control 4 of 6 over the City’s subdivision regulations for the design and development of this subdivision, where the City’s regulations would preclude the development of 2 units with a minimum of 800 square feet on either parcel. Engineering Division – Public Works/Community Development Department 11. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. See revisions on tentative map. 12. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) See revisions on tentative map. 13. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. See revisions on tentative map. 14. Provide any shared easements for parking, access, driveway, structural integrity (retaining wall, etc), drainage, irrigation, etc. See revisions on tentative map. 15. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. SB 9 does not require onsite parking where there is a car share within a block of the lot split. The City cannot impose requirements that would preclude the construction of two 800 sq. ft. residences. 16. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. See revised Feasibility Study attached. 17. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. SB 9 does not require a 10 foot minimum width driveway. Proposed Parcel 1 will have a 6 foot wide access easement and utilize onstreet parking with access to a car share. 18. Verify if “existing out building” is a permitted structure and is to remain. Garage is to be removed. A demolition permit application will be submitted after tentative approval of the lot split. 5 of 6 Building and Safety Division - Community Development Department 19. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. See revisions on tentative map. All buildings will comply with R302, California Residential Code. The out building that is showing less than 5 foot setbacks from the new property line will be removed. Any new construction will meet the requirements of the various building codes. 20. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] Building plans have not been submitted. Setbacks are shown on the tentative map. 21. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] There are none. Utilities Department 22. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. See revisions on tentative map. Additional comments not considered completeness comments: • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community 6 of 6 Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. These items will be addressed on an “as needed” basis as the project moves closer to applying for building permits. Fire Department 23. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. See revisions on tentative map. All buildings will comply with R302, California Residential Code. The out building that is showing less than 5 foot setbacks from the new property line will be removed. Any new construction will meet the requirements of the various building codes. 24. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. See revisions on tentative map. Sincerely, Kerry Margason, Planner MBS Land Surveys Michael B Stanton, PLS 5702 Ofc: 805.594.1960 3559 S. Higuera Street Cell: 805.440.4215 San Luis Obispo, Ca 93401 Fax: 805.594.1966 February 6, 2023 Hand Delivered to 919 Palm Street Owen Goode CDD Assistant Planner 919 Palm Street San Luis Obispo, CA 93405 Subject: Response to Incomplete Letter #2: SBDV-0458-2022 (619 Grove) Minor Subdivision potentially resulting in a flag lot (MBS 22-187) Dear Mr. Goode: Following is our response to the incomplete letter, dated January 10, 2023, for the above project. I have copied your letter and will respond directly under each item in red type. Department comments/completeness items: Planning Division - Community Development Department Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of-way. a. Revise plans to show compliant access to public right-of-way. Please clarify how the project will comply with the access to public right of way requirements under Senate Bill 9. Comment Remains. Access to both lots will be from Grove Street. There is an existing out building that is slated for removal in the future. An easement will be granted over proposed Parcel 2 to benefit proposed Parcel 1 (as shown on the tentative parcel map). The tentative parcel map has been revised to show the proposed easement. 619 Grove Street 2 of 6 As designed, proposed Lot 1 is not landlocked. It will have a 6-foot access easement and there will be a car share provided, per the SB 9 standards. Other standards of the City’s municipal code will be met as follows: R-1 Standards Parcel 1 Parcel 2 SETBACKS (Sec. 17.16.020) Front Setback 20’ 68 Existing 19.8’ Interior Setback 5’ 4’ and 4’ Existing 3.7 and 7.65’ Rear Setback 5’ 4’ 16.7’ MINIMUM LOT AREA (Sec. 16.18.030, 16.18.050) R1 Required Parcel 1 Parcel 2 Width 50’ 50’ 50’ Depth 90’ 39-50’ 68-80’ St. Frontage 20’ 6’ 50’ Width/Depth Ratio 3:1 1:1 1:1.3 MAXIMUM DENSITY (Sec. 17.16.020) R1 Required Parcel 1 Parcel 2 7 units/net acre (1 unit/6,000 sq.ft.) 1 unit per 2,409 sq.ft. 1 unit per 3,590 sq.ft. FLOOR AREA RATIO (FAR) (Sec. 17.16.020) Required Parcel 1 Parcel 2 0.4 maximum .33 0.26 LOT COVERAGE (Sec. 17.16.020) Maximum Allowed Parcel 1 Parcel 2 40% 33% 26% 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. Comment Remains. Parking will be directly behind the existing home. See the revised tentative parcel map. 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). OK. 619 Grove Street 3 of 6 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. OK. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. OK. 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. OK. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. OK. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. Comment Remains. Please provide a statement stating how the project cannot satisfy applicable standards of Table 3. See the table above under Item 1. Also see the example 800 square foot footprint on proposed Parcel 1. The footprint shows consistency with the rear and side setback requirements. The requirement for a 10 or 20’ access to proposed Parcel 1, over proposed Parcel 2 cannot be met, but SB 9 requirements will be met with a 6-foot access easement and there will be a car share provided for proposed Parcel 1. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. Comment Remains as a note until access to the right of way is shown. The project is not proposed as a flag lot subdivision. The project is proposed as a shared access subdivision, with the accessway being 6 feet wide. Please see the easement noted on the revised tentative map. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with all application requirements and objective standards identified in Chapter 16.17. Comment Remains as a note until access to the right of way is shown. The project is not proposed as a Common Interest Subdivision. Access is shown on the revised tentative parcel map as a 6’ wide access and utility easement. Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General Subdivision Design Standards) and revise plans as appropriate. 619 Grove Street 4 of 6 • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. Comment remains as a note. SB 9 does not require a minimum lot frontage. The proposed Parcel 1 will be provided access from the public street by way of an access easement, as shown on the parcel map. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). Comment remains as a note. The proposed project cannot meet a 10 foot wide driveway requirement. It will have a 6-foot access easement and there will be a car share provided, per the SB 9 standards. • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. Comment remains as a note. Gov. Code 66411.7(c) states: (c) (1) Except as provided in paragraph (2), notwithstanding any local law, a local agency may impose objective zoning standards, objective subdivision standards, and objective design review standards applicable to a parcel created by an urban lot split that do not conflict with this section. The objective standards cannot conflict. (2) A local agency shall not impose objective zoning standards, objective subdivision standards, and objective design review standards that would have the effect of physically precluding the construction of two units on either of the resulting parcels or that would result in a unit size of less than 800 square feet. A 20 foot wide road frontage requirement would precluding the construction of any units on the proposed second parcel. (3) (A) Notwithstanding paragraph (2), no setback shall be required for an existing structure or a structure constructed in the same location and to the same dimensions as an existing structure. (B) Notwithstanding paragraph (2), in all other circumstances not described in subparagraph (A), a local agency may require a setback of up to four feet from the side and rear lot lines. The proposed subdivision meets the requirements of Govt. Code 66411.7(c) because the local agency cannot impose a condition, in this case the lot frontage requirement, when the condition would preclude the development of an 800 square foot residence. Such a condition would preclude any development on the proposed parcel. Engineering Division – Public Works/Community Development Department 619 Grove Street 5 of 6 11. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. OK. 12. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) Comment remains See revised tentative parcel map. 13. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. Comment remains. See revised tentative parcel map. 14. Provide any shared easements for parking, access, driveway, structural integrity (retaining wall, etc), drainage (blanket drainage easement appears to have parcel numbers reversed), irrigation, etc. Comment remains. See revised tentative map, included here. 15. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. Comment remains Govt. Code 66411.7 (e) (3) states: 66411.7(e)(3): Off-street parking of up to one space per unit, except that a local agency shall not impose parking requirements in either of the following instances: (A) The parcel is located within one-half mile walking distance of either a high-quality transit corridor as defined in subdivision (b) of Section 21155 of the Public Resources Code, or a major transit stop as defined in Section 21064.3 of the Public Resources Code. (B) There is a car share vehicle located within one block of the parcel. A car share vehicle will be provided within one block of the project. 16. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. OK 17. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. Driveway shown as 7.65 feet. Comment remains. 619 Grove Street 6 of 6 The proposed project cannot meet a 10 foot wide driveway requirement. It will have a 6- foot access easement and there will be a car share provided, per the SB 9 standards. 18. Verify if “existing out building” is a permitted structure and is to remain. The existing structure at the end of the easement will be removed in the future. If you have questions on the above items, please contact Senior Civil Engineer, Charles Weir, (805) 783-7704, or by e-mail: cweir@slocity.org Building and Safety Division - Community Development Department 19. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. OK. Response (Include Sheet and Detail Number): 20. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] OK. Response (Include Sheet and Detail Number): 21. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] OK. Utilities Department 22. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. OK. • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. 619 Grove Street 7 of 6 Additional comments not considered completeness comments: • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. Fire Department 23. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. OK. Response (Include Sheet and Detail Number): 24. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. Comment Remains. A utility and access easement, benefitting proposed Parcel 1 is shown on the revised tentative map. All address numbering will be installed with building permits and will be visible from the public way. Please let me know if there are any further questions or concerns regarding this project. Michael B Stanton, PLS 5702 Ofc: 805.594.1960 3559 S. Higuera Street Cell: 805.440.4215 San Luis Obispo, Ca 93401 Fax: 805.594.1966 April 12, 2023 RESPONSE TO COMMENTS OF MARCH 9, 2023 MBS 22-187 SBDV-0458-2022 619 GROVE STREET Department comments/completeness items: Planning Division - Community Development Department 1. Government Code Section 66411.7(c) states that the Urban Lot Split shall comply with all applicable objective subdivision standards. The proposed lot split shall comply with all objective standards identified in Municipal Code Section 16.18 (including Lot Frontage requirements). Parcel 1 has been proposed as a land locked parcel and is not in compliance with objective standards. In accordance with Gov Code 66411.7(e)(2) the parcel is required to adjoin the public right-of-way. a. Revise plans to show compliant access to public right-of-way. Understood that the project proposal contains access to public right of way via access easement. Please refer to comment 8 to provide an accessway that complies with the objective subdivision standards. Substandard accessways shall only be approved by the Public Works Director. Car Share vehicle provided, no off street parking or access required. 2. If access to both lots is to be shared, please identify the location of the required parking space for the existing residence, that does not interfere with the accessway required for the newly created lot. Comment Remains. Please refer to engineering comments to provide compliant parking. Car Share vehicle provided, no off street parking or access required. 3. Please identify all setbacks for the existing structures to all property lines. Setbacks shall be provided with a minimum distance of five-feet from any existing 2 of 6 structures inclusive of the newly created property line (a four-foot setback may be available in limited circumstances where building and fire codes can be met). OK. 4. If a shared driveway is proposed, an agreement shall be recorded to reflect ownership of the accessway for Parcel 1. OK. 5. Please provide signatures from all affected parties on the preliminary title report consenting to the subdivision. OK. 6. Please provide two copies of the drainage study or explaining the drainage area tributary to the subdivision and a statement setting forth in detail the manner in which storm water runoff will enter the subdivision are required. OK. 7. Provide a statement of proposed improvements and landscape modifications that are necessary to satisfy parking requirements and the accessway to Parcel 1. OK. 8. Demonstrate compliance with applicable standards of Table 3 in 16.18.030 except for requirements that would physically preclude the development of an 800 square foot dwelling unit. Comment Remains. Please provide a statement stating how the project cannot satisfy applicable standards. Please specifically identify the objective standard that physically precludes the project from providing a 20’ access easement or access way and why the project is unable to comply. The proposed exception is only required because there are no feasible design options which could allow for site development of two minimum 800 square foot units on either of the two resulting parcels. For the purpose of this finding, existing improvements or development is not considered a physical constraint. A 20 ft access easement cannot be provided due to the existing home location. The home was a rental within the last 3 years and cannot be altered or modified to provide a 20 ft access easement, we request an exception to that development standard as it would preclude us from doing an urban lot split. See California Government Code section 66411.7(a)(3)(D)(iv). If the city has a suggestion on a way forward we are open to suggestions. As you know SB9 does not allow you to deny the subdivision because of development standards not being met. 9. If the project is proposed as a Flag Lot Subdivision demonstrate compliance with all objective standards identified in Section 16.18.060. Understood that this is not a Flag Lot Subdivision. 10. If the project is proposed as a Common Interest Subdivision demonstrate compliance with all application requirements and objective standards identified in Chapter 16.17. Understood that this is not a Common Interest Subdivision. 3 of 6 Additional Comments – These comments are not completeness comments but may directly affect the staff recommendation. Please review the Subdivision Regulations Chapter 16.18 (General SBDV-Subdivision Design Standards) and revise plans as appropriate. • Section 16.18.030 (Lot Dimensions), the lot does not satisfy lot frontage requirements. Comment remains as a note. • Per Engineering Code #2120, the existing driveway does not meet objective standards for required dimensions of the driveway that is intended to provide access to the newly created lot (10 feet). Comment remains as a note. • The Urban Lot Split application does not appear eligible under Gov. Code 66511.7, because the project does not comply with Gov. Code 66511.7(c) and is inconsistent with the objective standards of the Subdivision Regulations Chapter 16.18 for lot frontage requirements, as described above. Comment remains as a note. Engineering Division – Public Works/Community Development Department 11. Provide dimensions for site setbacks of existing buildings, and distance between existing structures to remain. OK. 12. Provide current utilities locations for Parcel 2 (Electrical line, telecommunications, sanitary sewer) and proposed utility access for Parcel 1 (electrical, sanitary sewer, domestic water, and telecommunications) Comment remains. 3rd Review: Show existing telecommunications and electrical utility access for Parcel 2. Comment remains. Proposed utility access for Parcel 1 should not state ADU assuming this is a proposed primary residence. Please contact engineering prior to resubmittal to confirm corrections. NOTE: New electrical may require underground instead of overhead lines. 13. Provide any easements for utility access such as electrical, domestic water, sanitary sewer, gas (if applicable), telecommunications, etc. OK. 14. Provide any shared easements for parking, access, driveway, structural integrity (retaining wall, etc), drainage (blanket drainage easement appears to have parcel numbers reversed), irrigation, etc. Comment remains. 3rd Review: Blanket drainage easement parcel numbers still shown as reversed. Comment remains. Please contact engineering prior to resubmittal to confirm corrections. 4 of 6 15. Provide plan for off-street parking and right of way approaches of both units to comply with Section 66411.7.e.3 to the satisfaction of the Planning department. Comment remains. Car share vehicle provided, no off street parking or car access required. 3rd Review: Provide justification for how proposed parking spot can be accessed from approach. As shown, it is unclear how vehicles can access this spot (turning radius, etc.). Demonstrate compliance with the City’s parking and driveway standards. Comment remains. Car share vehicle provided, no off street parking or car access required. 16. Feasibility study checklist has some portions incomplete and questions unanswered. Please complete. OK 17. Clarify or provide justification to address 10’ minimum driveway width requirement of future development of Parcel 1. Existing driveway width is not explicitly shown (this may be addressed in item 1 above) but assumed to be less than 10’ based on drawing scale. Driveway shown as 7.65 feet. Comment remains. 3rd Review: SB9 standards do not prescribe the alternative of a 6-foot access easement and car share in lieu of objective driveway requirement. Please show compliance with driveway width or approved alternative to the satisfaction of the fire, building, and planning divisions. Comment remains. Car share vehicle provided, no off street parking or car access required. Driveway should not be required if no off street parking is required. Fire does not need vehicle access as the property is not deep enough to necessitate it. 18. Verify if “existing out building” is a permitted structure and is to remain. Building and Safety Division - Community Development Department 19. The structures associated with the proposed property line adjustment must comply with section R302 of the California Residential Code. Additional information is required to deem the modification acceptable. Please illustrate all proposed building setbacks within the topographic map. Review and revise said plans for clarity. OK. 20. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license 5 of 6 expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code] OK. 21. Show the location of any designated flood plains, open space easements, or other development restricted areas on the site plan. [§R106.1.1 CRC] OK. Utilities Department 22. Show the locations, widths and purpose of all existing and proposed easements for utilities, shown by dashed lines, within and adjacent to the subdivision (including building setback lines, if known); all existing and proposed utilities including size of water lines and water meters, and the size and grade of sewer lines, location of manholes, fire hydrants, fire sprinkler backflow device, and fire sprinkler water lateral. Show how utilities would be provided for the proposed rear parcel. OK. Additional comments not considered completeness comments: • Any sewer lateral shall be located within the parcel boundary or have a sewer agreement to cross parcels, prior to issuance of a building permit. • Any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to issuance of a building permit. • In order to be reused, any existing sewer laterals proposed to serve the project must pass a video inspection per Chapter 13.08.395 of the City’s Municipal Code, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process to Matt LaFreniere, Permit Technician, Community Development, Engineering Development Review for review and approval by the Utilities Department prior to issuance of a Building Permit. Existing laterals that are not proposed to be reused shall be abandoned at the City main consistent with City standards. • Per Chapter 13.04.120 of the City’s Municipal Code, separate parcels will be supplied through individual water service connections and private service lines shall not cross parcel boundaries unless authorized by the Utilities Department. Fire Department 23. Show code compliant setbacks from existing buildings. Unsprinklered buildings shall be at least 5 feet from the new property line, sprinklered buildings may be no closer than 3 feet, although SB9 would increase that to a minimum of 4 feet. OK. 24. Provide legal fire department access from the public way to the newly created parcel. Building address numbers shall be visible from the public way. Egress from any new buildings on the created parcel shall have unobstructed access to the public way. 6 of 6 The Fire Marshal has significant safety concerns regarding the occupants of the land-locked parcel being able to safely egress to the public way considering the tight passage along the existing residence on a parcel the occupants of the rear property have no control over, does not have fire sprinklers and heat exposure from a structure fire would pose an eminent risk to those escaping to the public way and a reasonable size area of refuge is non-existent. For safety reasons, the fire department can’t support the application as submitted unless the applicant provides a map that conforms to the City’s lot frontage requirements that provides both egress and fire department access to the rear parcel. Comment Remains. [California Residential Code 311.1 Means of Egress, California Fire Code 1028.5 Access to a Public Way, California Fire Code 504.1] Spoke with Roger regarding access. Currently there is 7.65 ft between the existing house and the property line. There is an additional roughly 3 ft of open area on the other side of the property line that there is a prescriptive easement on as it has been used as a driveway for the subject property for decades. So there is over 10ft between the existing house and the neighboring fence which is more than sufficient. Even with only the 7.65 ft we meet all of the codes cited by Roger. There are no windows on the first story of the wall that is against the driveway. This seemed to satisfy Roger as well. PROPOSED PROJECT CONSISTENCY WITH CITY OF SAN LUIS OBISPO SUBDIVISION STANDARDS STATEMENTS OF EXCEPTION AND FINDINGS Project Name: 619 Grove Street Map No.: SLO 22-0042; APN: 001-056-029 R-1 Standards Parcel 1 Parcel 2 SETBACKS (Sec. 17.16.020) *Front Setback 20’ 68’ Existing 19.8’ *Interior Setback 5’ 5’ and 5’ Existing 3.7 and 7.65’ *Rear Setback 5’ 5’ 16.7’ MINIMUM LOT AREA (Sec. 16.18.030, 16.18.050) R1 Required Parcel 1 Parcel 2 **Width 50’ 50’ 50’ **Depth 90’ 39-50’ 68-80’ **Street Frontage 20’ 6’ 50’ ***Depth/Width Ratio 3:1 1:1 1:1.3 MAXIMUM DENSITY (Sec. 17.16.020) +R1 Required Parcel 1 Parcel 2 7 units/net acre (1 unit/6,000 sq.ft.) 1 unit per 2,409 sq.ft. 1 unit per 3,590 sq.ft. FLOOR AREA RATIO (FAR) (Sec. 17.16.020) Required Parcel 1 Parcel 2 Based on 800 sq. ft. unit 0.4 maximum 800 sq. ft. unit Existing LOT COVERAGE (Sec. 17.16.020) Maximum Allowed Parcel 1 Parcel 2 Based on 800 sq. ft. unit 40% 800 sq. ft. unit Existing Requested exceptions: This project requires exceptions to the Depth, Street Frontage, Density and potentially the FAR and Lot Coverage requirements of Sections 16 and 17 of the City’s Municipal Code. *Front, Interior and Rear Setbacks: The tentative parcel map shows a potential front setback of 68’, interior and rear setbacks of 5’. This is consistent with the subdivision requirements. The 19.8’ front setback and the 3.7’ rear setback for Parcel 2 are existing nonconforming. California Government code section 65852.21(b)(2)(B)(i) states that no setback for for an existing structure be required. A building envelope for a future 800 sq. ft. residential unit is shown on the tentative parcel map. The tentative building envelope conforms to all setback requirements. **Lot Width/Depth/Street Frontage: Required lot depth is 90’ for R1 zoned property. The depth of proposed Parcel 1 varies and is approximately 39-50 feet. Proposed Parcel 2 would be 68-80 feet. The underlying parcel size is approximately 120’ deep by 50’ wide, resulting in a parcel size of 6,000 sq. ft. Given the physical dimensions of the existing lot, there is no lot configuration that would allow for a 50 x 90’ size parcel. Street frontage is required to be 20’ for each lot. The existing lot dimensions would allow for a 25’ x 120’ size lot, except that there is an existing house on proposed Parcel 2. SB 9 regulations prohibit demolition of an existing residential unit that has been rented out in the past 3 years. State legislation (SB 9 Urban Lot development) has overridden some local planning standards, that when implemented, would preclude the construction of an 800 square foot residential unit, or 2 units, on a parcel divided under SB 9 parameters. Here, implementation of the lot/width local standards would preclude the subdivision and thereby preclude the construction of a residential unit. +Density: Density in the R1 zone is 1 dwelling unit/6,000 sq. ft. The proposed lots will result in 1 dwelling unit/approximately 3,000 sq. ft. The physical dimensions of the existing lot are approximately 120’ X 50’ = 6,000 sq. ft. State legislation (SB 9 Urban Lot development) has overridden some local planning standards regarding lot sizes and other standards, that when implemented, would preclude the construction of an 800 square foot residential unit, or 2 units, on a parcel divided under SB 9 parameters. Here, the underlying lot is 6,000 sq. ft. There is no division that could result in 2 lots of 6,000 sq. ft. It’s impossible. SB 9 allows for the creation of lots to a minimum of 1,200 sq. ft. Both proposed lots would meet or exceed the SB 9 criteria for an urban lot split 16.23.020 Required findings and conditions for exceptions. A. Before any exception is authorized, all of the following findings shall be made: 1. That the property to be divided is of such size or shape, or is affected by such topographic conditions, that it is impossible, impractical or undesirable, in the particular case, to conform to the strict application of the regulations codified in this title; the property to be divided is 6,000 sq. ft. and is the smallest residential lot allowed under the City’s zoning standards. Because of the size of the underlying lot, it is impossible and/or impractical to meet the City’s standards for lot/width, setbacks and density. 2. That the cost to the subdivider of strict or literal compliance with the regulations is not the sole reason for granting the modification; the cost to the subdivider was not taken into consideration when designing this proposed urban lot split. The proposed design is based on the property layout, City zoning regulations, SB 9 regulations, logical utility connections, and logical accessibility requirements. 3. That the modification will not be detrimental to the public health, safety and welfare, or be injurious to other properties in the vicinity: The modification will not be detrimental to the public health, safety, or welfare because it does not change the uses or residential nature currently established in the area. As designed, the project is consistent with the requirements of SB 9 Urban Lot Split legislation and will contribute to California’s housing crisis. 4. That granting the modification is in accord with the intent and purposes of these regulations and is consistent with the general plan and with all applicable specific plans or other plans of the city. Granting the modifications is in accord with the City’s goals/policies for in-fill development, balanced communities, and accelerated housing production as discussed in the Housing Element of the City’s General Plan. The modifications are also consistent with State goals and policies to create more housing for all income levels. B. In granting any exception, the commission or council shall impose such conditions as are necessary to protect the public health, safety and welfare, and assure compliance with the general plan, with all applicable specific plans, and with the intent and purposes of these regulations. (Ord. 1490 § 3 (part), 2006). Here, it would be up to the Planning Director/City Engineer to impose any necessary conditions and the conditions would have to be consistent with City policies and SB 9 regulations. GROVE STREETPARCEL 1PARCEL 2WILSON STREETSLO 22-0042TENTATIVE PARCEL MAP UPDATED 4/12/2023 SB 9 Urban Lot Split Feasibility Study Checklist Section 66411.7, Government Code Assigned Parcel Map No. SLO 22-0042 PROJECT LOCATION Street Address: 619 Grove City: San Luis Obispo County: San Luis Obispo APN: 001-056-029 Urban Area/Urban Cluster (per Census): Yes No (City boundaries include some portion of urbanized area/urban cluster per U.S. Census?) Zoning: R1-Low Den Combining designations: None Fire Hazard: Low Existing Parcel size (must be at least 2,400 sq. ft.): 6,000 sq.ft./0.13 acres Proposed sizes: Parcel 1: 2,409 sq.ft. (40%) (Parcels must be at least a 40%-60% split) Parcel 2: 3,591 sq.ft. (60%) Existing housing: Owner Occupied? Yes How long? Less than 1 year Rental? Yes The existing unit on the property was previously rented out and has been rented out in the last 3 years. If the current unit is a Rental, is it the subject of an affordable housing agreement or rent control ordinance? NO Has the owner used the Ellis Act to evict a tenant in the last 15 years? No PROJECT DESCRIPTION Describe the project being proposed: SB 9 Urban Lot 40/60 Split Will there be demolition or alteration of existing housing? No Was the original parcel created by an SB 9 lot split? No Have adjacent parcels been SB 9 divided by the same owner or someone acting in concert? (Same person/or agent cannot perform a lot split on adjacent lots.) _No Does Client intend to use the Two-Unit building component of SB 9? Not at this time THE FOLLOWING CRITERIA HAS BEEN MET: Ministerial approval of subdivision when: 1. Creates no more than 2 parcels 2. Parcels approximately equal size, based on 40%/60% split. 2nd parcel is a minimum of 40% the size of parent parcel. 3. Parcels are 1,200 sq. ft. or larger. 4. Parcel within a “single-family residential” zone. 5. Located within a city, where some portion of the city is within urban area or urban cluster. 6. No demolition or alteration of any of the following types of housing: a. Housing subject to “affordable” income rules, regulations, laws, covenants, etc. b. Housing where an owner(s) has used the Ellis Act to evict someone in the last 15 years (eviction because taking house out of rental market) c. Housing occupied by tenant in last 3 years. 7. Parcel not within a. Prime or Important Farmland (defined by Dept. of Ag. Land inventory or designated on Farmland Mapping & Monitoring Program of Dept. of Conservation or preserved by a local ballot measure. b. Wetlands c. Very high fire hazard zone d. Hazardous waste site e. Delineated earthquake fault zone f. Special flood hazard area subject to inundation by 100 year storm as determined by FEMA unless Letter of Map revision or site meets FEMA minimum flood plain management criteria g. Conservation area h. Habitat preservation area i. Under conservation easement