HomeMy WebLinkAboutHistoric Correspondence 2MEMORANDUM TO: 214 Higuera St.- FROM: Patrick Ledes RE: asphalt residue/sp ll behind dry cleaner DATE: 2/22/96 On November 22, 1995, Spencer and I responded to the above referenced address per the leasee's request to investigate a potential illegal dumping behind the dry cleaner. What was observed was asphalt residue that was left behind/dumped at the rear of the dry cleaner by the ashpalt company after they repaved the parking lot. It has since been addressed and no further action is expected. Photos are enclosed. end. PDL36.MEM Central Coast Regional Water Quality Control Board 81 Higuera street Suite 200 San Luis Obispo, CA 93401-5427 (805) 549-3147 FAX (805) 543-0397 HAZ MAT FILE March 17, 1997 Messrs. Jim & Angelo Morabito Paul's Dry Cleaners & Laundry 214 Higuera Street San Luis Obispo, CA 93401 Dear Mssrs. Morabito: SLIC: 214 HIGUERA STREET, SAN LUIS OBISPO, PAUL'S DRY CLEANERS & LAUNDRY; RESCISSION OF CLEANUP OR ABATEMENT ORDER NO.92-142 This is to rescind Cleanup or Abatement Order No. 92-142 (CAO No. 92-142), issued by this Board's Executive Officer on August 28, 1992. The tasks specified in the order were accomplished. However, we still consider it important that you maintain and monitor the wells you installed. A subsequent sampling detected PCE in groundwater downgradient of your business at a concentration in excess of that which you found upgradient of your site. Now that the drought is over, we request you have your wells resampled this fall (October) and next spring (March). This request is made pursuant to California Water Code Section 13267. Please direct questions to Frank I)eMarco at 805-542-4638 or Jay Cano at 805-549-3699. Sincerely, G2� Roger . Br1g� FJD/y:\Frank\res92142.doc bee: Maura Mahon c: Spencer Meyer City of San Luis Obispo Fire Department 2160 Santa Barbara Ave. San Luis Obispo, CA 93401-5240 �0D'&0vkdPqpff Owaksimistoprewwamdenhmm&WqWftycfWVornseek won resowm and C� mmm their proper al ooad= and c f ldW we for the b mjk of p w w and fw ww gemmdom Sent E : CORDOBA CONSULTING, INC.: 925 671 5472; Oct-3-00,10:21AM; f;ge 5/5 y-Cy e�0�0 tl: 3 I AM r KUM t tN V 1 KUNMtN I AL �J I b / -19 Oblb P. a i RECORD OF CONVERSATION 2 i 4 i+19i4e Kc- P"A" DvI Ci Q a VW,-S Date: September 22, 2000 With; Richard Alshire CCRWQCB 1 ?'6; t:; C- Phone: (805) 5424631 F-cw—g�x 010"6t Cc: Crary Maniery, PAR Melinda Rivasplata, PAR By: Christa Pay, PAR Environmental Services, Inc. Subject: PCE plume under 101/Prado Upon Caltrans review we discovered that there is a Petro-c.hloroethylene (PCE) plume under the project area. Caltrans provided a map and a contact. Y called Richard and asked questions about the plume. Toe said that it is in the shallow groundwater, which is located approximately 24 feet below ground surface. The concentrations of the PCE within this groundwater arc four tunes the maximum contaminate levels. He said that the plume came- from two dry cleaners. One located at 331 Pacific Street, which is now a kayak company, and one located on Higuera Street. Mr. Alshire said that he does not anticipate that our project will have an effect on the plume, or that the plume will have an effect on the project. If any de -watering is to occur, the water should be tested to see if it is clean. If it is not clean, then the water should be pumped from the ground and treated before it is released. This should occur only if dewatering is necessary_ SEP 28 2000 2027 916 739 0626 PAGE:. E a Sent B.. CORDOBA CONSULTING, INC.; 925 671 5472; Oct-3-0' 10:20AM; F =ge 1 uR.GEiv� � ■ To: MIKE MCCLUSKEY/TIM BOCHUM Voice Phone Number: (805) 781-7214 FAX (805) 781-7198 prom: ERIC CORDOBA Company: CORDOBA CONSULTING, INC. Fax Number: {925) 671-5472 Voice Number: ;(925) 671-5458 all MIKE/TIM, AS WE DISCUSSED LAST FRIDAY, COPIES OF CORRESPONDENCE FOR YOUR FILE THANKS!!! Date: 10102/00 Pages: 1 of 6 MEMORANDUM TO: Bill Hetland, Utilities Director FROM: Bob Neumann, Fire Marshal BY: Michael Smith, Hazardous Materials Inspector*) DATE: December 20, 1990 RE: Investigation of Possible TCE/TCA Groundwater Contamination - 214 Higuera St. BACKGROUND Earlier this year, the Regional Water Quality Control Board (RWQCB), contacted this office and requested information on businesses that use or have used TCE/TCA as part of their operations. At that time, the RWQCB was initiating an effort to investigate the groundwater contamination at the Dalidio wells. A review of Fire Department records for 214 Higuera Street, Paul's Dry Cleaners, indicated that a 1,000 gallon underground storage tank containing a dry cleaning solvent was in operation from 1952- 1987. This is significant since the average life span of an underground tank is approximately 15 years, under ideal conditions. Furthermore, because this tank was located inside the existing building, its removal, normally required, was waived and in 1987 authorization was granted for the abandonment and closure -in -place of this tank. It is important to note that during the tank abandonment process, an assessment of the area should have been conducted in order to verify whether the tank had lost any of its product into the surrounding soils or groundwater. This step was not done and the case was closed by this department. CURRENT With knowledge of the City's ongoing treatment of contaminated groundwater at both the Auto Parkway and Tali assumption that all dry cleaning operations only use perchloroethylene as their cleaning agent, I had considered this site as a potential point source, or at least contributor to the existing TCE/TCA contamination. This, however, is not the case. Upon further investigating the operations at this site and consulting with experts in the field, it was learned that petroleum solvents, namely stoddard solvent, is also used as a dry cleaning agent. Records show that the underground tank a 214 Higuera Street was used to store this type of petroleum solvent. It contains only aliphatic hydrocarbons. No chlorinated compounds are present. Only until recently (ten years ago), did the operators at this facility change over to perchloroethylene as their primary cleaning agent. In doing so, they also installed new equipment, which operates as a closed system. The perc is added directly to the equipment from drums or cans, not from the underground storage tank as previously thought. Accordingly, none of this product is discharged into the environment, except as air emissions. Therefore, based on this information, it is my recommendation that there is insufficient evidence to support any further investigation of this site. The products stored in the abandoned underground tank are not consistent with the compounds currently impacting groundwater. If there is still concern regarding the TCE/TCA contamination, existing City well data should be reviewed in conjunction with off -site analysis in order to characterize the contaminated zone. If you have further questions, please call me at extension #380. cc: Michael Dolder, Fire Chief Memorandum UNOCALS City of San Luis Obispo 728 Pismo Street San Luis Obispo, Ca. 93401 Attn: Michael Smith Dear Mr. Smith: December 5, 1990 Twl- d �w 5 L The attached Material Safety Data Sheets (MSDS's) for the products you have purchased from Unocal Chemicals Division have been carefully prepared in an effort to meet the worker right -to -know laws and to provide information necessary to your employee safety training program. It is very important that this information reach all individuals who will directiv or indirectly come in contact with the products. It is Unocal Chemicals Division's policy to constantly review its labels for completeness and compliance with various laws, ordinances, rules and regulations. If you repackage the product, you must pass this information on to our customers and their employees. If the product is hazardous, special warning labels must be affixed to the containers. You should also advise your customers and their employees of the potential hazards of the empty containers. "Empty" containers are those that contained product and have not been professionally cleaned and reconditioned. "Empty" containers should not be used for any purpose since they may contain explosive vapors. All containers, including empty or partially empty containers, should be stored in a secure area away from all heat, sparks (including static electricity), flames or other ignitable sources. Examples of our product labels (Industrial Use Only) are available upon request. Updated MSDS's will be provided as additional or different information becomes known to us. Our latest MSDS's contain the new OSHA permissible ew— concentrations of chemicals listed in SARA Title III Section 313 (40 CFR Part 372). The information contained herein should be used for specification purposes. If additional information is desired, please call the nearest Unocal Chemicals sales office. If there are other individuals in your company who should receive this information, we will be glad to supply additional sheets. Sincerely, G.W. McCloud Sr. Branch Administ tion Manager Attachments: 1104 FORM 1-00O3 (REV. 8-85) PRINTED IN U S.A MATERIAL 4ETY DATA SHEET Unocal Corpporation 1201 West 5th Street, P.O. Box 7600 Los Angeles, California 90051- Product Name: 365 SOLVENT Pagge 1 Product Code No: 11004 Issue Date: 12/OI/89 MANUFACTURER Transportation Emergencies: CHEMTREC UNOCAL CHEMICALS DIVISION - PETROCHEM. GROUP 0 424-9300 Cont. U.S. UNION OIL COMPANY OF CALIFORNIA 2; Mm 483-7616 (Collect) 1345 NORTH MEACHAM ROAD Alaskagg& Hawaii SCHAUMBURG, ILLINOIS 60196 Health EmANGEe Call ANKLES hOPOISON CONTACT FOR FURTHER INFORMATION: INFORMATION CENTER (24 hrs) YOUR LOCAL SALES OFFICE (LAST PAGE) 1-(800)-356-3129 PRODUCT IDENTIFICATION PRODUCT NAME: 365 SOLVENT GENERIC NAME: VOLATILE SOLVENT CHEMICAL FAMILY: PETROLEUM HYDROCARBON MIXTURE DOT PROPER SHIPPING NAME: PETROLEUM NAPHTHA ID NUMBER: UN1255 DOT HAZARD CLASSIFICATION: •COMBUSTIBLE LIQUID SECTION I - COMPONENTS PERCENT EXPOSURE LIMIT UNITS AGENCY TYPE HAZARDOUS COMPONENTS HYDROTREATED NAPHTHA, HEAVY CAS #: 64742-48-9 100.000 ppm ACGIH TWA 100.000 ppm MSHA TWA 200.000 ppm MSHA STEL 100.000 ppm OSHA TWA 100.000 ppm CAL OSHA TWA NAP LHA CAS #: 64741-41-9 100.000 ppm ACGIH TWA 100.000 ppm MSHA TWA 200.000 ppm MSHA STEL 100.000 ppm OSHA TWA 100.000 ppm CAL OSHA TWA OTHER COMPONENTS --NONE-- THIS PRODUCT CONTAINS THE FOLLOWING CHEMICALS SUBJECT TO THE REPORTING REQUIREMENTS OF SARA 313 AND 40 CFR 372: CAS NUMBER WEIGHT % --NONE-- NOTE: NAPHTHA, HEAVY AND HYDROTREATED NAPHTHA, HEAVY ARE COMPARABLE TO STODDARD SOLVENT. UOLUN V11. l.V. Product Name: 365 SOLD f Page 2 Product Code No: 11004 Issue Date: 12/OI/89 SECTION II - EMERGENCY AND FIRST AID PROCEDURES ***EMERGENCY*** Have physician call LOS ANGELES POISON INFORMATION CENTER (24 hrs) (800) 356-3129 EYE CONTACT: IF IRRITATION OR REDNESS DEVELOPS, MOVE VICTIM AWAY FROM EXPOSURE AND INTO FRESH AIR. FLUSH EYES WITH CLEAN WATER. IF SYMPTOMS PERSIST, SEEK MEDICAL ATTENTION. SKIN CONTACT: REMOVE CONTAMINATED SHOES AND CLOTHING AND CLEANSE AFFECTED AREA(S) THOROUGHLY BY WASHING WITH MILD SOAP AND WATER. IF IRRITATION OR REDNESS DEVELOPS AND PERSISTS, SEEK MEDICAL ATTENTION. TNHATATION (BREATHING) IF RESPIRATORY SYMPTOMS DEVELOP, MOVE VICTIM AWAY FROM SOURCE OF EXPOSURE AND INTO FRESH AIR. IF SYMPTOMS PERSIST, SEEK MEDICAL ATTENTION. IF VICTIM IS NOT BREATHING, IMMEDIATELY BEGIN ARTIFICIAL RESPIRATION. IF BREATHING DIFFICULTIES DEVELOP, OXYGEN SHOULD BE ADMINISTERED BY QUALIFIED PERSONNEL. SEEK IMMEDIATE MEDICAL ATTENTION. INGESTION (SWALLOWING): ASPIRATION HAZARD: DO NOT INDUCE VOMITING OR GIVE ANYTHING BY MOUTH BECAUSE THIS MATERIAL CAN ENTER THE LUNGS AND CAUSE SEVERE LUNG DAMAGE. IF VICTIM IS DROWSY OR UNCONSCIOUS, PLACE ON THE LEFT SIDE WITH THE HEAD DOWN. IF POSSIBLE, DO NOT LEAVE VICTIM UNATTENDED. SEEK MEDICAL ATTENTION. SECTION III - HEALTH HAZARDS/ROUTES OF ENTRY EYE CONTACT: THIS MATERIAL MAY CAUSE MILD EYE IRRITATION. DIRECT CONTACT WITH THE LIQUID OR EXPOSURE TO VAPORS OR MISTS MAY CAUSE STINGING, TEARING AND REDNESS. SKIN CONTACT: THIS MATERIAL MAY CAUSE MILD SKIN IRRITATION. PROLONGED OR REPEATED CONTACT MAY CAUSE REDNESS, BURNING, AND DRYING AND CRACKING OF THE SKIN. NO HARMFUL EFFECTS HAVE BEEN DEMONSTRATED IN SKIN ABSORPTION STUDIES. PERSONS WITH PRE-EXISTING SKIN DISORDERS MAY BE MORE SUSCEPTIBLE TO THE EFFECTS OF THIS MATERIAL. INHALATION (BREATHING): THIS MATERIAL IS EXPECTED TO HAVE A LOW DEGREE OF TOXICITY BY INHALATION. BREATHING HIGH CONCENTRATIONS OF VAPORS OR MISTS MAY CAUSE IRRITATION OF THE NOSE AND THROAT AND SIGNS OF NERVOUS SYSTEM DEPRESSION (E.G., HEADACHE DROWSINESS DIZZINESS LOSS OF —COORDIN r iiGUE RESFI�uxY Sic'M AT w PRE-EXISTING LUNG DISORDERS (E.G., ASTHMA -LIKE CONDITIONS) MAY BE AGGRAVATED BY EXPOSURE TO THIS MATERIAL. INGESTION (SWALLOWING) - WHILE THIS MATERIAL HAS A LOW DEGREE OF TOXICITY, INGESTION OF EXCESSIVE UANTITIES MAY CAUSE IRRITATION OF THE DIGESTIVE TRACT AND SIGNS OF NERVOUS SYSTEM DEPRESSION (E.G., HEADACHE, DROWSINESS, DIZZINESS, LOSS OF COORDINATION, AND FATIGUE). ASPIRATION HAZARD - THIS MATERIAL CAN ENTER LUNGS DURING SWALLOWING OR VOMITING AND CAUSE LUNG INFLAMMATION AND DAMAGE. COMMENTS: THIS MATERIAL HAS NOT BEEN IDENTIFIED AS A CARCINOGEN BY NTP, IARC OR OSHA. REPORTS HAVE ASSOCIATED REPEATED AND PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGE (SOMETIMES REFERRED TO AS SOLVENT OR PAINTERS' SYNDROME). INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND INHALING THIS PRODUCT MAY BE HARMFUL OR FATAL. THIS PRODUCT IS SOMETIMES USED AS A DRY-CLEANING UNION OIL CO. — Product Name: 365 SOL\ T Pate 3 Product Code No: 11004 Issue Date: 12/0 /89 SECTION III - HEALTH HAZARDS/ROUTES OF ENTRY SOLVENT. RETAINED SOLVENT IN ABSORBENT CLOTHING (E.G. SHOULDER PADS) THAT REMAINS IN CONTACT WITH THE SKIN FOR PROLONGED PERIODS HAS CAUSED SEVERE SKIN DAMAGE. CARE MUST BE TAKEN TO ENSURE THAT GARMENTS CLEANED WITH SOLVENTS ARE COMPLETELY DRY BEFORE BEING WORN. (SECTION IV - SPECIAL PROTECTION INFORMATION VENTILATION: IF CURRENT VENTILATION PRACTICES ARE NOT ADEQUATE TO MAINTAIN AIRBORNE CONCENTRATIONS BELOW THE ESTABLISHED EXPOSURE LIMITS (SEE SECTION I), ADDITIONAL VENTILATION OR EXHAUST SYSTEMS MAY BE REQUIRED. WHERE EXPLOSIVE MIXTURES MAY BE PRESENT, ELECTRICAL SYSTEMS SAFE FOR SUCH LOCATIONS MUST BE USED. RESPIRATORY_ PROTECTION: THE USE OF RESPIRATORY PROTECTION IS ADVISED WHEN CONCENTRATIONS EXCEED THE ESTABLISHED EXPOSURE LIMITS (SEE SECTION I). DEPENDING ON THE AIRBORNE CONCENTRATION, USE A RESPIRATOR OR GAS MASK WITH APPROPRIATE CARTRIDGES AND CANNISTERS (NIOSH APPROVED, IF AVAILABLE) OR SUPPLIED AIR EQUIPMENT. PROTECTIVE GLOVES: THE USE OF GLOVES IMPERMEABLE TO THE SPECIFIC MATERIAL HANDLED IS ADVISED TO PREVENT SKIN CONTACT AND POSSIBLE IRRITATION. EYE PROTECTION: APPROVED EYE PROTECTION TO SAFEGUARD AGAINST POTENTIAL EYE CONTACT, IRRITATION OR INJURY IS RECOMMENDED. OTHER PROTECTIVE EQUIPMENT: IT IS SUGGESTED THAT A SOURCE OF CLEAN WATER BE AVAILABLE IN THE WORK AREA FOR FLUSHING EYES AND SKIN. IMPERVIOUS CLOTHING SHOULD BE WORN AS NEEDED. SECTION V - REACTIVITY DATA REACTIVITY: STABLE UNDER NORMAL CONDITIONS OF STORAGE AND HANDLING. CONDITIONS AFFECTING REACTIVITY: AVOID ALL POSSIBLE SOURCES OF IGNITION (SEE SECTIONS VII AND VIII). INCOMPATIBLE MATERIALS: THIS PRODUCT IS INCOMPATIBLE WITH STRONG ACIDS OR BASES, OXIDIZING AGENTS AND SELECTED AMINES. HAZARDOUS DECOMPOSITION PRODUCTS: COMBUSTION MAY YIELD CARBON MONOXIDE AND/OR CARBON DIOXIDE. DO NOT BREATHE SMOKE OR FUMES. WEAR APPROPRIATE PROTECTIVE EQUIPMENT. HAZARDOUS POLYMERIZATION: WILL NOT OCCUR POLYMERIZATION CONDITIONS TO AVOID: NONE KNOWN Product Name: 365 SOLVENT UNION OIL CO. Product Code No: 11004 e 5 SECTION VIII - FIRE AND EXPLOSION HAZARD DATA Issue Date: 12/0 /89 HMIS HEALTH HAZARD: 1 HHAZSASRD FLAMMABILITY: 2 CLAREACTIVITY: 0 PPE: LOWER EXPLOSIVE LIMIT ($ VOL.) UPPER EXPLOSIVE LIMIT $ VOL. 0.7 6.0 EXTINGUISHING MEDIA: DRY CHEMICAL, CARBON DIOXIDE, HALON, FOAM OR WATER SPRAY IS RECOMMENDED. UNUSUAL FIRE & EXPLOSION HAZARDS: THIS MATERIAL IS COMBUSTIBLE AND MAY BE IGNITED BY HEAT, SPARKS FLAME OR OTHER SOURCES OF IGNITION (e.g. STATIC ELECTRICITY, PILOT LIGHTS, MECHANICAL/ELECTRICAL EQUIPMENT). VAPORS HAY TRAVEL CONSIDERABLE DISTANCES TO A SOURCE OF IGNITION WHERE THEY MAY IGNITE FLASHBACK OR EXPLODE. VAPOR/AIR EXPLOSION IN SEWERS. VAPORS ARE HEAVIER THAN AIR AND MAY ACCUMULATE INHLOZW ARE INDOORS OUTDOORS OR IS NOT PROPERLY COOLED, IT MAY EXPLODE IN THE HEAT OF A FIRE. I� CONTAINER SPECIAL FIRE FIGHTING PROCEDURES: WEAR APPROPRIATE PROTECTIVE EQUIPMENT INCLUDING RESPIRATORY PROTECTION AS CONDITIONS WARRANT (SEE SECTION IV). STOP SPILL/RELEASE IF IT CAN BE DONE WITHOUT RISK. MOVE UNDAMAGED CONTAINERS FROM FIRE AREA I IT CAN BE DONE WITHOUT RISK. WATER SPRAY BE USEFUL IN MINIMIZING OR DISPERSING VAPORS AND COOLING EQUIPMENT EXPOSED TO HEATAND FLAME. AVOID SPREADING BURNING LIQUID WITH WATER USED FOR COOLING PURPOSES AND SECTION IX - PHYSICAL DATA ***UNLESS OTHERWISE NOTED, VALUES ARE AT 20 C/68 F AND 760 mm Hg/1 atm. APPROX BOILING POINT (AIR - 1) VAPOR DENSITY (N-BUTYL ACETATE - 1) EVAPORATION -RATE 310 - 405 F )1$ VOLATILE SOLUBILITY IN WATER0.2 100 VAPOR PRESSURE (rnm H� <0.1 2.0 SPECIFIC GRAVITY 0.77 (60 F/60 F) AP--PEARANCE LITTLE IF ANY COLOR, LIQUID ODOR CHARACTERISTIC SECTION X - PRECAUTIONARY WARNING APPROX. BULK DENSITY lb al 6.41 (60 F) CAUTION! COMBUSTIBLE. ASPIRATION HAZARD IF SWALLOWED. CAN ENTER LUNGS AND CAUSE DAMAGE. KEEP AWAY FROM HEAT, SPARKS, FLAME OR OTHER SOURCES OF IGNITION (E.G. S ELECTRICITY PILOT LIGHTS OR'MECHANICAL E UIPMENT VOMITING. FiRST AIPHYSIICIAN. INS�ASET��NCHAZARD QQ STATIC IF SWALLOWED, DDONNOT TINDUCE R WATER. , FLUSH EYES OR SKIN WITH PLENTY OF