Loading...
HomeMy WebLinkAboutAgenda Report, MOD-0028-2026 (3427 Roberto Ct) ADMINISTRATIVE HEARING AGENDA REPORT SUBJECT: Request to modify a bar/tavern use permit (USE-3598-2016) to extend hours of operation for the tasting room, revise conditions to allow a small-scale craft distillery, and remove parking conditions that no longer apply to the site. PROJECT ADDRESS: 3427 Roberto Ct. BY: Eva Wynn, Assistant Planner Phone Number: (805) 781-7172 FILE NUMBER: MOD-0028-2026 Email: ewynn@slocity.org APPLICANT: Randy Coates REPRESENTATIVE: Ryan Brocket, Architect RECOMMENDATION Approve the request to modify an existing Minor Use Permit (USE-3598-2016), which established a bar/tavern use at 3427 Roberto Court in the Manufacturing (M) zone, to extend operating hours for alcohol tasting, revise the ABC license type allowed, and remove parking conditions related to previous site uses, based on the recommended findings and conditions of approval. SITE DATA Applicant Randy Coates Figure 1 – Project Site General Plan Land Use Designation Service and Manufacturing (SM) Zone Manufacturing (M) Site Area ~ 24,000 square feet Environmental Determination Categorically exempt from environmental review under CEQA Guidelines Section 15301 (Existing Facilities) SUMMARY Randy Coates (Applicant) has requested a Modification to a previously approved Minor Use Permit (MUP; USE-3598-2016) that allows the operation of a bar/tavern at 3427 Roberto Court in the Manufacturing (M) zone. The proposed modification includes a request to extend operating hours to 11:00 a.m. to 10:00 p.m. daily, revise the allowed ABC license type to Type 74/06 (Craft Meeting Date: 4/13/2026 MOD-0028-2026 Administrative Hearing Report – April 13, 2026 Distiller), and remove parking conditions related to previous site uses (see Attachments A and B - Project Description and Project Plans). The original approval of the Minor Use Permit established the bar/tavern use as a cidery (production and tasting), and modifications to this use are subject to review and approval by the Community Development Director. To facilitate the change from cider tasting to a small-scale craft distillery tasting room, a building permit for the tenant improvements is required. 1.0 PROJECT BACKGROUND 1.1 Prior Minor Use Permit Review and Approvals On January 11, 2016, the Administrative Hearing Officer reviewed and approved a Minor Use Permit (USE-3598-2016) to allow operation of a tasting room for a cider production facility (Two Broad Ciderworks) and a 10% parking reduction at 3427 Roberto Court (Attachment C – USE- 3598-2016 Approval Letter). The building permit to establish the use was completed in 2019, establishing cider production and tasting operations in Suites 120-130. In August of 2025, a building permit was issued for the tenant improvement for a new food preparation use in Suite 110, where an auto-shop was previously located. The tenant improvement included additional updates to the production and bar/tavern use in Suites 120-130. The proposed improvements were determined to be in substantial conformance with the existing use permit, and a modification was not required at that time. The proposed business operations have since changed, as described in this report, which require modification to the use permit (USE-3598-2026). 1.2 Site and Setting The project site is a parcel at the edge of the Manufacturing (M) zone, on the northwestern side of Roberto Ct. The parcel is comprised of a single-story, 5,996 square foot structure, that includes alcohol production and the bar/tavern under modification review. Other uses in the structure include food preparation and office/storage space. Surrounding the project site, on the northeast and south, are a cider production and tasting room use, light manufacturing uses, and research and development uses that are also zoned for Manufacturing (M). Properties north of the project are residential, zoned as High-Density Residential (R-4-PD). The Alrita-Carla Creek provides a natural buffer between the Manufacturing and Residential zones. Present Use & Development Developed property with an existing multi-tenant building and site improvements such as access and parking. Topography Relatively flat with creek located along the northern property line Access Roberto Court Zones & Surrounding Uses North: R-4-PD; multi-unit residential uses South: M; business service, office, and wholesaling uses East: M; manufacturing, alcohol tasting, and office uses West: M; manufacturing and office uses 1.3 Project Description The Applicant has applied for a Modification to the existing Minor Use Permit (USE-3598-2016) to request amended tasting room operations. The modifications requested include (a) removing MOD-0028-2026 Administrative Hearing Report – April 13, 2026 parking conditions that limit hours of operation due to outdated building operations, (b) amending the hours of operation for tasting between 11:00 a.m. to 10:00 p.m., and (c) revising conditions that limit business operations as a Type 2 (Winegrower). The updated project description requests to operate as a craft distillery with a Type 74 (Craft Distiller) and Type 6 (Still) ABC license (see Attachments A and B - Project Description and Project Plans). Modification to Staggered Parking Conditions When the original bar/tavern use was permitted in 2016, the site included an auto-repair shop in Suite 100-110, and the combined parking of the auto-shop and bar/tavern use would exceed the 11 available parking spaces on-site. To accommodate the two uses, Conditions No. 2-3 required that the auto-repair shop use and the bar/tavern use would not overlap hours, providing sufficient parking based on operational hours. A 10% parking reduction was granted under the same approval. 2. The property owner shall ensure 11 parking spaces are available for the Two Broads Ciderworks use from 5 pm - 10 pm weekdays and from 12 pm -10 pm on the weekends. 3. The property owner shall ensure 8 parking spaces are available for the existing auto repair shop from 8 pm - 5 pm weekdays. The current uses on-site include food preparation, storage, and alcohol production and tasting. Based on the current uses, the 11 on-site parking spaces satisfy the parking requirement of 11.2 parking spaces, verified with the 2025 tenant improvement submittal (BLDG-1157-2025). The change in hours and license type do not change or intensify the parking requirement. As such, the applicants have requested to remove Conditions No. 2-3 from the existing use permit. Modification to Previously Approved Hours of Operation While the project would continue to operate seven (7) days a week, amended hours of operation for tasting are requested between 11:00 a.m. and 10:00 p.m., instead of between 5:00 p.m. - 10:00 p.m. on weekdays and 12:00 p.m. – 10:00 p.m. on weekends. (Attachment C – Condition No. 8 of USE-3598-2016 Approval Letter). The applicant is not requesting later evening hours beyond what was previously permitted (Attachment A – Project Description). Modification to Bar/Tavern Use The project requests to change the type of bar/tavern operation to allow for a new craft distillery tenant. USE-3598-2016 approved the use of a bar/tavern for ABC license designation “Winegrower” and stipulated that the license could not be exchanged for the “Public Premises” license type. To accommodate the new tenant, the applicant requests to revise Condition No. 12 to allow the “Craft Distiller” license type with a “Still”. 2.0 PROJECT ANALYSIS Per Table 2-1 (Uses Allowed by Zone), establishment of a bar/tavern (e.g., tasting room or area) requires approval of a Minor Use Permit in the Manufacturing (M) Zone. Approval of the Use Permit and any subsequent modifications are subject to requirements, outlined in Section 17.110.060 (Criteria for Approval) and Section 17.110.070 (Required Findings), for consistency with applicable standards and limitations of the General Plan and Zoning Regulations. Staff has evaluated the project against relevant standards and guidelines and found it to be in compliance as MOD-0028-2026 Administrative Hearing Report – April 13, 2026 discussed in the following analysis. 2.1 Consistency with the General Plan The project is located in the Services and Manufacturing land use designation, which the Land Use Element (LUE) describes as intended for a wide range of service and manufacturing uses to meet the needs of the city and some demands of the region. Certain areas may be reserved through special zoning provisions for certain types of uses to assure compatibility among the wide range of potential uses, and to assure adequate land for certain types of uses (Table 1 – General Plan Land Use Designations). Zoning regulations in Chapter 17.10.020 (Use Regulations) conditionally allow bar/tavern uses, including craft distillery tasting rooms, that are consistent with Chapter 17.86.050 (Alcoholic beverage sales—Bars and restaurants with late night alcohol service) and City Policies within the M zone. The modifications requested by this application will not change the land use designation or accessory uses previously approved. 2.2 Consistency with Zoning Regulations Parking for Prior Uses At the time the use was permitted in 2016, the adjacent suite was an auto-shop which had a higher parking requirement. The auto-shop has since vacated and is now a food preparation facility, lowering the parking requirement to 1 parking space per 1,500 square feet for Suite 110. The combined parking requirement for the building is satisfied with the existing 11 parking spaces, and the conditions to stagger parking are no longer applicable to existing uses. No additional parking is required as no additional square footage is added compared to the previous cider production/tasting use. Staff recommends removing Condition No. 2-3 of USE-3598-2016 based on updated site conditions removing the need for staggered parking. Hours of Operation The applicant is requesting to extend their hours of operation for the bar/tavern use. This alteration to the existing hours of operation approved in 2016 is intended to provide additional operating hours while minimizing impacts on surrounding properties. The Police Department has reviewed the proposed request and does not have any concerns about the extended hours of operation. As such, staff recommends modifying Condition No. 8 of USE-3598-2016, adjusting the hours of operation to 11:00 AM to 10:00 PM daily (MOD-0028-2026, Condition No. 6). This will extend the hours of operation by one hour on weekends and six hours on weekdays to allow the bar/tavern use to open for lunch and afternoon service. Expansion of operating hours will not extend hours later than the hours originally permitted in 2016. Bar/Tavern Use – Craft Distiller The applicant is requesting to modify Condition No. 12 which approved the bar/tavern use for a Type 02 “Winegrower” license. The request for a Type 06 “Still” and Type 74 “Craft Distiller” license would allow the applicant or tenants of the bar/tavern space to distill alcohol on-site, sell distilled spirits wholesale, and sell limited amounts of distilled spirits to consumers at the licensed premises (MOD-0028-2026, Condition No. 10). The project shall continue to comply with provisions outlined in Section 17.86.050 (Alcoholic Beverage Sales – Bars and Restaurants with Late Night Alcohol Service), and the operational requirements apply, with the exception of Menu Service. The project is not required to provide full MOD-0028-2026 Administrative Hearing Report – April 13, 2026 meals and restaurant service as the request is limited to onsite tasting for an alcohol production facility. While menu service is not required by use permit, food service is not prohibited as an accessory use to the bar/tavern use. Additional Staff Recommended Updates to Conditions (USE-3598-2016) • Planning Conditions. Replace Condition No. 7 with updated language to clarify when Use Permits must be recommended for re-review with an Administrative Hearing. This is an update based on standard language for Use Permit conditions to allow the applicant an opportunity to resolve minor violations before being recommended for Administrative Hearing review (MOD-0028-2026, Condition No. 5). • Public Works Conditions. Remove Conditions No. 25-29 which are code requirements and are not applicable to the proposed modifications, as determined by Community Development Engineering staff. • Utilities Conditions. Remove Conditions No. 30, 31, and 34 which have been satisfied or are otherwise no longer applicable, as determined by the Utilities Department. • Utilities Conditions. Include language regarding grease interceptor calculations to Condition No. 32 which applies if food preparation is included as part of the bar/tavern use (MOD-0028-2026, Condition No. 22). • Urban Forestry Conditions. During review of the Modification request, Planning Division staff noted that Condition No. 35 of USE-3598-2016 required two native trees be planted at the top of bank to provide bank stabilization and screening of the patio as seen from adjacent residences to the north. The required trees do not appear to exist on the plans or site, and staff recommend the condition remain as a requirement of this modification. The draft conditions require the two native trees be planted prior to occupancy of the use and maintained to the satisfaction of the City Arborist. The condition includes maintenance standards and requires consistency with City tree planting standards (MOD-0028-2026, Condition No. 24). 3.0 ENVIRONMENTAL REVIEW The project is categorically exempt under Class 1, Existing Facilities; Section 15301 of the State California Environmental Quality Act (CEQA) Guidelines, because the project consists of the modification of hours of operation for businesses within an existing building located within an urbanized area and will not have a significant effect on the environment. 4.0 ATTACHMENTS A - Project Description B - Project Plans C - USE-3598-2016 Decision Letter ACTION  Approve, based on findings and subject to conditions listed below  Approve as modified, based on findings and subject to conditions listed below  Deny MOD-0028-2026 Administrative Hearing Report – April 13, 2026  Continue to: _______________________to allow ______________________________________________________________________________ ___________________________________  Continue indefinitely to allow: ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ________ MOD-0028-2026 Administrative Hearing Report – April 13, 2026 FINDINGS 1. The project is consistent with the General Plan and Zoning regulations because modifications to the bar/tavern is allowed when approved with a Use Permit. Additionally, the design, location, size, and operating characteristics of the project will be compatible with existing and future land uses in the vicinity because the proposed modifications would not provide additional accessory tasting area for an existing production use and is compatible with neighboring manufacturing, cider production and tasing, and residential uses. 2. The project is consistent with the Zoning Regulations and the 2012 Alcohol Outlet Regulations because required conditions of approval are included that have been identified to reduce public safety concerns associated with alcoholic beverage sales, and provide for properly maintained alcohol outlets so that negative impacts generated by these activities are not harmful to the surrounding environment. 3. As conditioned, the site is physically suitable in terms of (a) its design, location, shape, size, and operating characteristics of the proposed modifications, (b) traffic generation and provision of public and emergency vehicle (e.g., fire and medical) access, (c) public protection services (e.g., fire protection, police protection, etc.), and (d) the provision of utilities (e.g., potable water, schools, solid waste collection and disposal, storm drainage, wastewater collection, treatment, and disposal). The project site is surrounded by other developed properties, has access to the City’s circulation system, and will be served by existing utility services. Additionally, the project is sufficiently served by both vehicle and bicycle parking onsite, will provide additional plantings along the top of bank, and does not include activities that generate service or utility demands beyond those anticipated with uses permitted in the vicinity. 4. As conditioned, the use will not harm the general health, safety, and welfare of people living or working at the site or in the vicinity because conditions will minimize potential impacts such as noise consistent with the limitations established under the City’s Noise Ordinance as well as impacts to police resources and the community. 5. The proposed use is compatible with the project site and with existing uses in the vicinity which include offices, food preparation, cider tasting, and other light manufacturing uses. Conditions of approval have been adopted to minimize potential disturbances and criminal activities. 6. The existing 10% parking reduction is maintained because 5 additional bicycle parking spaces are provided on site in lieu of one vehicle parking space, consistent with San Luis Obispo Municipal Code Section 17.16.060. 7. The project is categorically exempt under Class 1, Existing Facilities; Section 15301 of the State California Environmental Quality Act (CEQA) Guidelines, because the project consists of the modification of hours of operation for businesses within an existing building located within an urbanized area and will not have a significant effect on the environment. CONDITIONS Planning Division 1. A building plan check submittal that is in full conformance with submitted project plans, and incorporating the following conditions of approval, shall be submitted for review and approval of the Community Development Department. A separate, full-size sheet shall be included in MOD-0028-2026 Administrative Hearing Report – April 13, 2026 working drawings submitted for a building permit that lists all conditions of project approval. Reference shall be made in the margin of listed items as to where in plans requirements are addressed. 2. The property owner shall ensure that any changes to Suites 100-120 will be compatible with the operation of the bar/tavern use and the approval of this use permit, including available on- site parking. 3. The proposed outdoor patio shall be no larger than 325 sf. due to parking limitations. 4. The proposed use shall operate in accordance with the submitted project description. The Use Permit shall be reviewed by the Community Development Director for compliance with conditions of approval, or to determine whether a modification of the Use Permit is necessary upon significant change to the business as represented in the applicant’s submitted project application materials dated March 27, 2026, or in the event of a change in ownership which may result in deviation from the project description or approved plans. 5. If the City receives substantiated evidence supporting the conclusion that a violation of this Use Permit, or of City ordinances has occurred; and if the Community Development Director determines the violations have not been adequately resolved, the Use Permit shall be reviewed at an Administrative Hearing. At the time of the Use Permit review, to ensure on-going compatibility of the uses on the project site, conditions of approval may be added, deleted, modified, or the Use Permit may be revoked. 6. Hours of operation for the proposed Bar/tavern use may operate between the hours of 11:00 a.m. - 10:00 p.m. daily. The outdoor patio area shall be closed to all patrons no later than 10 p.m. nightly. Changes in the hours of operation shall require an amendment to this use permit or require an additional use permit as determined by the Community Development Director. 7. This Use Permit does not include the review of any exterior modifications, and is limited to the use of the project site. Any new exterior modifications shall be reviewed separately for consistency with the General Plan, Zoning Regulations, and Community Design Guidelines. 8. Tables, chairs, and the general floor plan layout shall remain consistent with approved plans and may not be removed or modified for late night operation or special events unless approved by the Community Development Director in advance, or if approved by separate permit. 9. Live or amplified entertainment that meets the definition of a Night Club shall not be allowed at this location without the approval of a Night Club Use Permit. 10. This use permit is approved for ABC alcohol license designation “Craft Distiller” and may not be exchanged for the “Public Premises” license type (Bar/Tavern). 11. The proposed use shall operate in conformance with the City Noise Ordinance (M.C. Chapter 9.12, Noise Control) to maintain compatibility with the nearby residences and businesses. 12. The site shall be maintained in a neat and orderly manner at all times, to the satisfaction of the Community Development Director. 13. The applicant shall not permit its patrons to leave the licensed premises with any alcoholic beverage or to consume alcoholic beverages on any property adjacent to the licensed premises under the control of the licensee(s). 14. To address complaints and minimize the need for police response to minor issues, an owner or manager shall be on premises at all times, and shall be available to be contacted by a City MOD-0028-2026 Administrative Hearing Report – April 13, 2026 representative and/or adjacent property owner or tenant. The applicant shall provide and regularly update contact information to the City’s Police, Fire, and Community Development Departments and adjacent property owners and tenants, or any interested members of the public. 15. The applicant shall maintain and operate a video recording system that records activity at all entrances and exits during all business hours. The video shall be of a quality suitable for later identification of customers and staff. It will be recorded in a manner that may be retrieved and provided to the Police Department immediately upon demand. Video data shall be retained for a minimum of 72 hours or as otherwise required by law. 16. The applicant is responsible at all times for verifying the legal age of patrons, for monitoring patrons’ on-site alcohol consumption, and for declining to serve alcohol to patrons who demonstrate signs of intoxication or impairment associated with alcohol consumption, based on training provided to all staff. 17. All employees shall attend ABC LEAD Training or equivalent training, to the satisfaction of the Police Chief. 18. The applicant shall be responsible for on-going security/safety training to accommodate changes in personnel. 19. Business shall be conducted in a manner that will not violate any provisions of the California Alcoholic Beverage Control Act, prohibiting the sale of alcohol to minors (§25658), maintaining the public health, morals, convenience, and safety (§25601); and taking reasonable steps to correct any objectionable conditions on the premises and immediately adjacent to the premises (§24200). 20. The maximum posted occupant load for each space shall not be exceeded at any time. This permit is strictly limited to allow only the occupant load for the premises as approved by the City of San Luis Obispo Fire Department. Occupant loads approved by the City of San Luis Obispo Fire Department shall be posted at all times. 21. Bar area shall be made accessible to persons with disabilities, subject to the approval of the Chief Building Official. Utilities 22. If the proposed use includes food preparation, or any type of process discharge, a pre- treatment design shall be provided with the site plan, and a pre-treatment application shall be completed. The pre-treatment application will need to be coordinated with the building department, and the City’s Industrial Waste Program Manager. Grease interceptor calculations must be provided on the building permit plans for review and approval. Code Requirement(s) 23. The proposed utility infrastructure shall comply with the latest engineering design standards in effect during the time a building permit is obtained, and shall have reasonable alignments and clearances needed for maintenance. Natural Resources/Urban Forestry 24. Prior to occupancy, two (2) new native riparian trees (Platanus racemosa, Populus fremontii or Populus trichocarpa) shall be sourced in accordance with the Guideline Specifications for Nursery Tree Quality and planted per the City’s Engineering Standards for Tree Planting at MOD-0028-2026 Administrative Hearing Report – April 13, 2026 the top of the creek bank to the satisfaction of the City Arborist. Provide photographic evidence to the City Arborist (wgault@slocity.org) that trees have been planted. All required trees shall survive and any trees that do not survive or establish in good health, to the satisfaction of the City Arborist, shall be replanted. INDEMNIFICATION The applicant shall defend, indemnify and hold harmless the City and/or its agents, officers and employees from any claim, action or proceeding against the City and/or its agents, officers or employees to attack, set aside, void or annul, the approval by the City of this project, and all actions relating thereto, including but not limited to environmental review (“Indemnified Claims”). The City shall promptly notify the applicant of any Indemnified Claim upon being presented with the Indemnified Claim and City shall fully cooperate in the defense against an Indemnified Claim." NOTICE OF OPPORTUNITY TO PROTEST The applicant acknowledges and agrees that the project conditions of approval stated herein provide adequate and proper notice pursuant to Government Code 66020 of the applicant’s right to protest any requirement for fees, dedications, reservations, other exactions, and that any protest in compliance with Section 66020 must be made within ninety (90) days of the date that notice was given. DISCLOSURE The conditions of approval and additional information provided as code requirements and/or informational notes in this approval [letter / resolution] do not represent an exhaustive list of mandatory code requirements. The additional information provided is intended for the applicant’s reference for subsequent permitting steps and requirements. Once detailed construction documents for the building permit application are submitted, the project will be reviewed for code compliance, which may result in additional requirements that were not identified or reported in the planning review process. 03/27/26 Minor Use Permit Modification 3427 Roberto Court, San Luis Obispo, CA APN: 053-063-019 Project Description & Final Modification Goals: The proposed tenant business in Suites 120 & 130 (alcohol production, storage & tasting room areas) will operate as a small-scale craft distillery under Type 74/06 license, with on-site manufacturing as the primary use within a fully enclosed industrial building. A secondary bar/tavern component, consistent with existing use entitlements (USE-3598-2016) and Building Permit (BLDG-1157-2025), will allow on-site alcohol service within designated interior areas and a shared outdoor patio space approved under the current building permit and utilized by on-site tenants. The operation is not intended to function as a stand-alone restaurant. Proposed hours of operation are 11:00 a.m. to 10:00 p.m. daily. We are not requesting later evening hours beyond what was previously permitted. The overall intensity of use is comparable to or less than the previously approved manufacturing and tasting room use, and parking will continue to be accommodated through an existing shared parking arrangement among on-site tenants & uses in Suite 100 (storage) and Suite 110 (food prep & storage). Seeking Modifications to previous USE-3598-2016 dated 1/11/17: Planning #2 & #3, Request to remove conditions because different hours are no longer needed and all required parking is accounted for in parking calculations. No parking allocation is needed for an auto shop, as that use no longer exists on the property. Planning #8, revise hours of operation as noted above Planning #12, revise license type as required Attachment A - Project Description RYAN M BROCKETT C-32384 REN 12 31 27 LI CE N S E D ARCHI T E C T S T A T E OF A L I F O RNIA C DATE ISSUE OW N E R / 34 2 7 R O B E R T O L L C 18 9 C O U N T R Y S I D E L N SA N L U I S O B I S P O , C A 9 3 4 0 1 THESE DOCUMENTS INCLUDE ORIGINAL WORK, INSTRUMENTS OF SERVICE, AND INTELLECTUAL PROPERTY OF RYAN BROCKETT ARCHITECT INC. THE DESIGN AND INFORMATION REPRESENTED IN THESE DRAWINGS ARE SOLELY FOR USE WITH THIS PROJECT AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. 05.15.25 PERMIT 07.25.25 RESUBMIT 1 08.18.25 RESUBMIT 2 08.25.25 RESUBMIT 3 02.17.26 REVISION 34 2 7 R O B E R T O C T , S A N L U I S O B I S P O , C A 9 3 4 0 1 AP N / 0 5 3 - 0 6 3 - 0 1 9 20 2 5 B R O C K E T T A R C H I T E C T S / I N T E R I O R S C TITLE SHEET T1.0 3427 ROBERTO CT, SAN LUIS OBISPO, CA APN / 053-063-019 PERMIT SET REVISION 02/17/26 CLIENT: 3427 ROBERTO LLC 189 COUNTRYSIDE LN SAN LUIS OBISPO, CA 93401 805 / 234 1220 R DOOBIE COATES HIGHSTDELI@GMAIL.COM STRUCTURAL ENGINEER: MURPHY STRUCTURAL ENGINEERS 1500 PALM ST, UNIT C SAN LUIS OBISPO, CA 93401 805 / 748 3693 CHRIS MURPHY, SE CHRIS@MURPHYSE.COM MECHANICAL & PLUMBING ENGINEER: 3C ENGINEERING 1500 PALM STREET SAN LUIS OBISPO, CA 93401 805 / 540 5358 BRIAN STARRETT, PE BSTARRETT@3CENG.COM PROJECT DIRECTORY APPLICABLE CODES TITLE / GENERAL: T1.0 TITLE SHEET T2.1 GENERAL NOTES T3.1 CALGREEN NON-RESIDENTIAL MANDATORY MEASURES T3.2 CALGREEN NON-RESIDENTIAL MANDATORY MEASURES T3.3 CALGREEN NON-RESIDENTIAL MANDATORY MEASURES T4.1 CODE COMPLIANCE PLAN T5.1 HEALTH DEPARTMENT REQUIREMENTS T5.2 HEALTH DEPARTMENT REQUIREMENTS ARCHITECTURAL: A1.1 SITE PLAN A2.1 EXISTING FLOOR PLAN A2.2 OVERALL PROPOSED FLOOR PLAN A2.3 PROPOSED FLOOR PLAN WEST A2.4 PROPOSED FLOOR PLAN EAST A2.5 REFLECTED CEILING PLAN A2.6 ROOF PLAN A3.1 EXTERIOR ELEVATIONS A4.1 BUILDING SECTIONS A7.1 DETAILS A7.2 DETAILS STRUCTURAL: S1.1 GENERAL NOTES S1.2 TYPICAL DETAILS S2.1 FOUNDATION PLAN S2.2 CEILING FRAMING PLAN S2.3 ROOF FRAMING PLAN S3.1 DETAILS S4.1 ROOF EQUIPMENT DETAILS MECHANICAL: M0.0 GENERAL M0.1 SCHEDULES M0.2 DETAILS M0.3 DETAILS M0.4 KITCHEN HOOD DETAILS M0.5 KITCHEN HOOD DETAILS M0.6 KITCHEN HOOD DETAILS M1.0 ZONING PLAN M1.1 OVERALL FLOOR PLAN M1.2 ROOF PLAN T24.0 ENERGY COMPLIANCE DOCUMENTATION T24.1 ENERGY COMPLIANCE DOCUMENTATION T24.2 ENERGY COMPLIANCE DOCUMENTATION PLUMBING: P0.0 GENERAL P0.1 DETAILS P1.0 OVERALL FLOOR PLAN P1.1 FLOOR PLAN - WASTE & VENT P1.2 FLOOR PLAN - WATER & GAS P1.3 FLOOR PLAN - WASTE & VENT P1.4 FLOOR PLAN - WATER & GAS P1.5 MEZZANINE PLAN P1.6 ROOF PLAN ELECTRICAL: E1.0 ELECTRICAL AND LIGHTING PLAN E2.0 ELECTRICAL DETAILS E-T24 LIGHTING ENERGY FORMS SHEET INDEX AC AIR CONDITIONER ADJ ADJACENT AFF ABOVE FINISH FLOOR ALGN ALIGN ALUM ALUMINUM ARCH ARCHITECT/ARCHITECTURAL AVG AVERAGE BD BOARD BLDG BUILDING BLKG BLOCKING BM BEAM BOT BOTTOM BTWN BETWEEN CJ CONTROL JOINT CL CENTERLINE CLKG CAULKING CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS CT CERAMIC TILE CTR CENTER CW COLD WATER CY CUBIC YARD DBL DOUBLE DEG DEGREE DIA DIAMETER DIM DIMENSION DN DOWN DS DOWNSPOUT DW DISHWASHER (E) / EXST EXISTING EA EACH ELEC ELECTRICAL ELEV ELEVATION / ELEVATOR EQ EQUAL EQUIP EQUIPMENT EXT EXTERIOR FAU FORCED AIR UNIT FD FLOOR DRAIN FE FIRE EXTINGUISHER FF FINISH FLOOR FIN FINISH FG FINISH GRADE F.O. FACE OF FP FIREPLACE FTG FOOTING GGAS GA GAUGE GALV GALVANIZED GYP BD GYPSUM BOARD HB HOSE BIB HT HEIGHT HW HOT WATER INCL INCLUDE INSUL INSULATION INT INTERIOR JAN JANITOR KIT KITCHEN LAV LAVATORY MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MICRO MICROWAVE MIN MINIMUM MTD MOUNTED MTL METAL (N) NEW NG NATURAL GRADE NTS NOT TO SCALE O/ OVER OC ON CENTER OH OVERHEAD / OVERHANG OPNG OPENING OS OCCUPANCY SENSOR PL PROPERTY LINE / PLATE PLYWD PLYWOOD PT PRESSURE TREATED PTD PAINTED PR PAIR R RISER RCP REFLECTED CEILING PLAN REF REFRIGERATOR REQ REQUIRED REV REVISED / REVISION RM ROOM RO ROUGH OPENING SF SQUARE FOOT SHTG SHEATHING SIM SIMILAR STD STANDARD STL STEEL SUSP SUSPENDED T TREAD / TEMPERED T&G TONGUE & GROOVE T.P. TOP OF TYP TYPICAL UC UNDER COUNTER UON UNLESS OTHERWISE NOTED VIF VERIFY IN FIELD VS VACANCY SENSOR W/ WITH WC WATER CLOSET WD WOOD WH WATER HEATER WIC WALK IN CLOSET W/O WITHOUT WT WEIGHT ABBREVATIONS REFERENCE NOTE DETAIL TAG DOOR TAG WINDOW TAG EQUIPMENT TAG SECTION TAG EXTERIOR / INTERIOR ELEVATION TAG 1. ALL WORK PERFORMED SHALL COMPLY WITH THE CONTRACT DOCUMENTS, INCLUDING ALL ARCHITECTURAL AND CONSULTANT DRAWINGS, NOTES, SPECIFICATIONS AND SEPARATE DOCUMENTS, TO ACCOMPLISH A COMPLETE PROJECT. ANYTHING REASONABLY IMPLIED OR INTENDED SHALL BE INCLUDED. REVIEW ALL DOCUMENTS THOROUGHLY AND CLARIFY ALL AMBIGUITIES OR DISCREPANCIES WITH ARCHITECT PRIOR TO BIDDING OR COMMENCING CONSTRUCTION. 2. ARCHITECTURAL DIMENSIONS, DETAILS AND NOTES TAKE PRECEDENCE OVER DRAWING SCALE. TYPICAL DETAILS AND NOTES APPLY IN SIMILAR CONDITIONS. DO NOT PERFORM ANY WORK THAT DOES NOT CONFORM TO THESE DRAWINGS WITHOUT PRIOR APPROVAL. 3. ALL PLAN, ELEVATION AND SECTION DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF FRAMING, CENTERLINE OF DOOR, CENTERLINE OF WINDOW AND CENTERLINE OF FIXTURE, UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS SHALL ALWAYS GOVERN. CONTACT ARCHITECT FOR ANY DIMENSIONS THAT ARE NOT NOTED PRIOR TO COMMENCING ANY WORK. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SITE SAFETY, CLEANLINESS AND SECURE SITE TO PREVENT UNAUTHORIZED ACCESS. PROTECT ALL EXISTING CONSTRUCTION TO REMAIN, INCLUDING PUBLIC IMPROVEMENTS AND ADJACENT STRUCTURES. 5. ALL WORK IN ALL TRADES SHALL BE OF HIGHEST QUALITY AND BE INSTALLED TRUE, PLUMB, LEVEL, SQUARE, CLEAN, AND IN PROPER ALIGNMENT. CORRECT EXISTING FRAMING CONDITIONS TO REMAIN AS REQUIRED. INSTALL ALL FIXTURES, EQUIPMENT AND MATERIALS PER THEIR MANUFACTURER INSTRUCTIONS AND RECOMMENDATIONS. PROVIDE ALL NECESSARY BLOCKING, BACKING, HANGERS, AND/OR OTHER SUPPORTS FOR ALL EQUIPMENT, FIXTURES, MILLWORK, ETC. VERIFY CLEARANCES FOR ALL FINISHES, FIXTURES, FLUES, VENTS, CHASES, SOFFITS, ETC. PRIOR TO COMMENCING ANY WORK. 6. THE CONSTRUCTION AREA SHALL BE THOROUGHLY CLEANED, INCLUDING THE ENTIRE BUILDING AND SITE UPON COMPLETION. FINAL CLEANING SHALL INCLUDE REMOVAL OF ALL DEBRIS, TRASH, UNUSED AND UNWANTED MATERIALS, TOOLS, ETC. AS WELL AS THOROUGH CLEANING OF ALL SURFACES, FIXTURES, EQUIPMENT AND APPLIANCES. REMOVE ALL TEMPORARY STICKERS ON GLASS AND CLEAN BOTH SIDES OF ALL PANES. ALL EQUIPMENT, FIXTURES, APPLIANCES, DEVICES, DOORS, WINDOWS, HARDWARE, ETC. SHALL BE TESTED TO ENSURE THAT THEY ARE IN PROPER WORKING ORDER. AGENCY DIRECTORY ALL CONSTRUCTION, REGARDLESS OF THE DETAILS ON THE DRAWINGS, SHALL COMPLY WITH THE FOLLOWING CODES AND THEIR MOST RECENT AMENDMENTS: 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ELECTRICAL CODE (NEC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (CEC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) CITY OF SAN LUIS OBISPO MUNICIPAL CODE, TITLE 15 BUILDINGS & REGULATIONS CITY OF SAN LUIS OBISPO MUNICIPAL CODE, TITLE 17 ZONING REGULATIONS PROJECT NOTES PROJECT DATA DRAWING SYMBOLS AGENCY NOTES ARCHITECT: RYAN BROCKETT ARCHITECT INC. 104 S MAIN ST, UNIT B TEMPLETON, CA 93465 805 / 400 3025 RYAN BROCKETT, AIA LEED AP RYAN@BROCKITECTURE.COM CALIFORNIA LICENSE C-32384 ELECTRICAL ENGINEER: POWER & COMMUNICATIONS ENGINEERING 1009 MORRO ST, SUITE 205 SAN LUIS OBISPO, CA 93401 805 / 541 9700 GREG NOTLEY, PE GREG@POWERCOMENGINEERING.COM PROJECT SITE ORCUTT RD R O B E R T O C T . SAC R A M E N T O D R . B R O A D S T . VICINITY MAP X X X X AX.X X AX.X X AX.X X AX.X 1 2 3 4 FINISH TAGX X X WALL TAG N PROJECT DESCRIPTION: COMMERICAL TENANT IMPROVEMENTS TO AN EXISTING METAL BUILDING WITH MULTIPLE EXISTING TENANTS. REMODELED TENANT SPACES INCLUDING ALCOHOL TASTING, FOOD PREPARATION, AND STORAGE AREAS. EXISTING ADJACENT STORAGE AREAS TO REMAIN. PROPOSED SCOPE OF WORK INCLUDES THE FOLLOWING: x REMODEL OF SUITE 130 (E) ALCOHOL CIDER PRODUCTION, STORAGE & TASTING ROOM AREAS TO (N) ALCOHOL SPIRIT PRODUCTION, STORAGE & TASTING ROOM AREAS UNDER A SMALL SCALE MANUFACTURING WITH A BAR/TAVERN "TYPE 74/06 LICENSE". x REMODEL OF SUITE 110 (E) MOTOR VEHICLE REPAIR TO (N) FOOD PREPARATION & STORAGE AREA x NO CHANGES TO SUITE 100 (E) BUSINESS OFFICE & STORAGE x (E) OUTDOOR PATIO, LANDSCAPING, PARKING & TRASH AREAS TO REMAIN x (E) ROOF, EXTERIOR STRUCTURAL FRAMING AND BUILDING UTILITIES TO REMAIN (E) COMMERCIAL FIRE SPRINKLER MODIFICATIONS TO BE A DEFERRED SUBMITTAL. PARCEL INFORMATION: PROJECT ADDRESS: 3427 ROBERTO CT, SAN LUIS OBISPO, CA 93401 ASSESSOR'S PARCEL NUMBER: 053-063-019 ZONING: (M) MANUFACTURING PLANNING AREA: CITY OF SAN LUIS OBISPO LOT SIZE: 0.55 ACRES ESTIMATED AVG SLOPE: 2.0% OVERALL YEAR BUILT: 1980 FIRE HAZARD SEVERITY ZONE: NON-VHFSZ, LOCAL RESPONSIBILITY CLIMATE ZONE: 5 FLOOD ZONE: X UTILITIES: MUNICIPAL WATER & SEWER; ELECTRIC & GAS PROJECT INFORMATION: OCCUPANCY GROUP, EXISTING: A-2, F-2, S-2 & S-1 OCCUPANCY GROUP, PROPOSED: A-2 & S-2 USE, EXISTING: CIDERY, MOTOR VEHICLE REPAIR & STORAGE USE, PROPOSED: SPIRIT PRODUCTION & TASTING, FOOD PREP & STORAGE CONSTRUCTION TYPE: VB FIRE SEPARATION: NOT-SEPARATED; NOT REQ'D BETWEEN A-2 & S-2 FIRE SPRINKLERS: REQUIRED & EXISTING; TO BE MODIFIED PHOTOVOLTAIC SYSTEM: NONE REQUIRED & NONE PROVIDED OCCUPANCY SEPARATION: 1-HR BUILDING AREAS: (NO OVERALL CHANGES PROPOSED) EXISTING BUILDING (E) SUITE 100 STORAGE 1,300 SF (E) SUITE 110 MOTOR VEHICLE REPAIR 1,678 SF (E) SUITE 130 PRODUCTION, CIDER TASTING & STORAGE 3,018 SF OVERALL EXISTING BUILDING 5,996 SF PROPOSED BUILDING (E) SUITE 100 OFFICE & STORAGE 1,300 SF (R) SUITE 110 FOOD PREP & STORAGE 1,678 SF (R) SUITE 130 SPIRIT PRODUCTION, TASTING & STORAGE 3,018 SF OVERALL PROPOSED BUILDING 5,996 SF TOTAL AREA OF PROPOSED TI 4,705 SF (78.5%) SITE AREAS: (NO CHANGES PROPOSED) (E) OVERALL SITE 23,668 SF (.55 AC) (E) LOT COVERAGE 5,996 SF (25%) (E) IMPERVIOUS SURFACES 8,278 SF (35%) (E) LANDSCAPING 9,594 SF BUILDING DATA: (NO CHANGES PROPOSED) NUMBER OF FLOORS: 1 OVERALL EXISTING HEIGHT: +/-17'-0" ABOVE AVG. FINISH GRADE ALLOWED HEIGHT: 35'-0" EXISTING SETBACKS: 10' FRONT, 0' SIDE, 20' REAR PARKING DATA: (NO CHANGES PROPOSED) EXISTING PARKING: 10 STANDARD PARKING SPACES 1 ADA VAN ACCESSIBLE PARKING SPACES 8 SHORT TERM BIKE PARKING RACKS PARKING CALCULATIONS: (NOT INCLUDING CIRCULATION & RESTROOMS) BAR/TAVERN (1 PER 100 SF) 823 SF / 100 = 8.2 ACCESSORY RETAIL (1 PER 300 SF) 235 SF / 300 = 0.8 FOOD PREP (1 PER 1,500 SF) 1,255 SF / 1,500 = 0.8 STORAGE (1 PER 1,500 SF)2,091 SF / 1,500 = 1.4 TOTAL (11 SPACES EXISTING & REQUIRED) 11.2 ELECTRIC VEHICLE CHARGING: N/A; NO PROJECT ADDITION PROPOSED PROJECT CALCULATIONS: OCCUPANCY CALCS (SEE SHEET T4.1): 87 OCCUPANTS TOTAL INDOOR; 110 OVERALL PLUMBING CALCS (SEE SHEET T4.1): 116 OCCUPANTS OVERALL 1. PROJECT IS EXEMPT FROM FULL COMPLIANCE FROM DISABLED ACCESS REQUIREMENTS BASED ON VALUATION THRESHOLD PER DATE OF APPLICATION PER CBC SECTION 11B-202.4 2. CALGREEN SECTION 301.3 DOES NOT APPLY TO THIS ALTERATION PROJECT, DUE TO PROJECT PERMIT VALUATION IS LESS THAN $200,000 3. REMODELING PRE-1978 STRUCTURES WITHOUT USING LEAD SAFE WORK PRACTICES IS A VIOLATION OF THE CALIFORNIA HEALTH AND SAFETY CODE SECTION 105256. CONTRACTORS, REMODELERS AND PAINTERS ARE REQUIRED TO USE "LEAD-SAFE" WORK PRACTICES PERSUANT TO TITLE 17, CALIFORNIA CODE OF REGULATIONS SECTION 36050". CONSTRUCTION DEBRIS KNOWN TO CONTAIN LEAD-BASED PAINT MUST BE DISPOSED AT AN APPROVAL LOCATION. 4. NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS NUMBERS SHALL BE APPROVED IN ADDITIONAL APPROVED LOCATIONS TO FACILITATE EMERGENCY RESPONSE. ADDRESS NUMBERS SHALL BE ARABIC NUMERALS OR ALPHABET LETTERS. NUMBERS SHALL BE A MINIMUM OF COMMERCIAL 8 INCHES HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCHES. 5. ALL COMMERCIAL BUILDINGS SHALL INSTALL A KNOX KEY BOX FOR FIRE DEPARTMENT EMERGENCY ACCESS, CFC SECTION 506.1. THE BOX SHALL BE INSTALLED PRIOR TO FINAL INSPECTION FOR THE BUILDING. AND ORDER FORM IS AVAILABLE FROM THE PREVENTION BUREAU, CALL FOR MORE INFORMATION AT 805-543-4244 CITY OF SAN LUIS OBISPO / COMMUNITY DEVELOPMENT DEPT 919 PALM ST SAN LUIS OBISPO, CA 93401 805 / 781 7180 CITY OF SAN LUIS OBISPO / PLANNING & BUILDING DIVISIONS 919 PALM ST SAN LUIS OBISPO, CA 93401 805 / 781 7180 CITY OF SAN LUIS OBISPO / PUBLIC WORKS DEPT 919 PALM ST SAN LUIS OBISPO, CA 93401 805 781 / 7220 SAN LUIS OBISPO CITY FIRE DEPT 2160 SANTA BARBARA AVE SAN LUIS OBISPO, CA 93401 805 / 781 7380 DEFERRED SUBMITTALS COMMERCIAL FIRE SPRINKLERS: ANY CHANGES TO EXISTING FIRE SPRINKLER SYSTEM, FIRE ALARM SYSTEM & COMMERCIAL KITCHEN HOOD FIRE SUPPRESSION SYSTEM; SUBMIT PLANS & HYDRAULIC CALCULATIONS FIRE SUPPRESSION SYSTEM FOR TYPE I KITCHEN HOOD: PLANS & CALCS BAKING EQUIPMENT: ROTATING SINGLE RACK BAKING OVEN WITH INTEGRATED TYPE II HOOD; SUBMIT SPECS, TESTING DOCUMENTATION AND OWNER REVIEW LETTER GREASE TRAP / GREASE LINES: PLANS & CALCS FOR GREASE LINES TO REQUIRED FIXTURES; GREASE INTERCEPTOR SIZE Attachment B - Project Plans 116 SF SERVICE 99 SF STANDING 32 LF 53 SF STOR204 SF STORAGE 76 SF UTILITY 90 SF SERVICE 172 SF TABLES & CHAIRS 167 SF TABLES & CHAIRS 24 SF JAN (E) ENTRY & EXIT DOOR (E) ENTRY & EXIT DOOR (E) ENTRY & EXIT DOOR 200 SF STORAGE 234 SF STORAGE 1175 SF COMM KITCHEN (834 W/O EQUIP) 56 SF SERVICE 94 SF TABLES & CHAIRS (E) RR EMPLOYEE (E) RR PUBLIC (E) STORAGE 840 SF S-2 (E) STORAGE 460 SF S-2 (N) FOOD PREP 1,678 SF A-2 (R) SPIRIT TASTING 3,018 SF A-2 150 SF RETAIL 85 SF RETAIL 85 SF TABLES & CHAIRS 325 SF TABLES & CHAIRS 460 SF OUTDOOR STORAGE EXISTING STORAGE AREAS NOT IN SCOPE OF WORK, NO CHANGES PROPOSED 26'-9" > 1/3 MAX D I A G O N A L 78'-9" M A X O V E R A L L D I A G O N A L 38 38 7 (E) ENTRY & EXIT DOOR X ISA TX ISA ISA TX TX X X O O F F F F A A 75 ' M A X E X I T T R A V E L D I S T 85' MAX EXIT TRAVEL DIST EXIT PATH TO PUBLIC WAY MIN 4' WIDE 22"24"48 " 24 SF SPIRIT PRODCT. (EQUIP ONLY) (E) RR PUBLIC DETECTABLE WARNINGS MIN 3' WIDE RYAN M BROCKETT C-32384 REN 12 31 27 LI CE N S E D ARCHI T E C T S T A T E OF A L I F O RNIA C DATE ISSUE OW N E R / 34 2 7 R O B E R T O L L C 18 9 C O U N T R Y S I D E L N SA N L U I S O B I S P O , C A 9 3 4 0 1 THESE DOCUMENTS INCLUDE ORIGINAL WORK, INSTRUMENTS OF SERVICE, AND INTELLECTUAL PROPERTY OF RYAN BROCKETT ARCHITECT INC. THE DESIGN AND INFORMATION REPRESENTED IN THESE DRAWINGS ARE SOLELY FOR USE WITH THIS PROJECT AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. 05.15.25 PERMIT 07.25.25 RESUBMIT 1 08.18.25 RESUBMIT 2 08.25.25 RESUBMIT 3 02.17.26 REVISION 34 2 7 R O B E R T O C T , S A N L U I S O B I S P O , C A 9 3 4 0 1 AP N / 0 5 3 - 0 6 3 - 0 1 9 20 2 5 B R O C K E T T A R C H I T E C T S / I N T E R I O R S C 0 N8 1/8" = 1'-0"SCALE: 421161 CODE COMPLIANCE PLAN CODE COMPLIANCE PLAN T4.1 SHEET LEGEND OCCUPANCY LOAD FACTORS OCCUPANCY GROUPS: A-2 RESTAURANT/BAR S-2 LOW-HAZARD STORAGE OCCUPANCY LOAD FACTORS (PER CBC 2022 TABLE 1004.1.2): ACCESSORY STORAGE AREAS 300 GROSS ASSEMBLY UNCONCENTRATED 15 NET (TABLES & CHAIRS) ASSEMBLY CONCENTRATED 7 NET (CHAIRS ONLY) ASSEMBLY STANDING 5 NET BAR SEATING 18" PER SEAT COMMERCIAL KITCHEN, SERVICE 200 GROSS BUSINESS 150 GROSS MERCANTILE 60 GROSS WAREHOUSES 500 GROSS OCCUPANCY AREA BOUNDARY FURNITURE FOR REFERENCE, SHOWN DASHED EXIT PATH OF TRAVEL ACCESSIBLE LEVEL DOOR CLEARANCE ACCESSIBLE CLEAR FLOOR AREA, 30" X 48" LOCATION OF ACCESSIBLE SEATING INTERNATIONAL SYMBOL OF ACCESSIBILITY (E) PHOTOLUMINESCENT EXIT SIGNS, ELECTRICAL NOT REQ. TACTILE EXIT SIGNS SEMI RECESSED FIRE EXTINGUISHER OCCUPANT LOAD POSTED SIGNAGE OCCUPANCY CALCULATIONS A-2, SPIRIT TASTING, PRODUCTION & STORAGE AREAS: TABLES & CHAIRS 433 SF / 15 NET = 28.9 BAR SEATING 32 LF / 18" PER SEAT= 19.2 ADA BAR SEATING ONE PLUS COMP = 2.0 BAR STANDING 99 SF / 5 NET = 19.8 BAR SERVICE 206 SF / 200 GROSS = 1.0 STORAGE 480 SF / 300 GROSS = 1.6 SPIRIT PRODUCTION 24 SF / 200 GROSS = 0.1 MERCANTILE 235 SF / 60 GROSS = 3.9 TOTAL (>49 OCC, 2 EXITS REQ'D) 76.5 OCC A-2, FOOD PREP AREA: COMM KITCHEN 1,175 SF / 200 = 5.9 SERVICE 56 SF / 200 = 0.3 STORAGE 311 SF / 300 =1.0 TOTAL (<49, 1 EXIT REQ'D) 7.2 OCC S-2, ADJACENT STORAGE AREA (NOT IN SCOPE) STORAGE 1,300 SF / 500 = 2.6 OCC TOTAL INDOOR 87 OCC OUTDOOR AREAS OUTDOOR PATIO 325 SF / 15 = 21.7 OUTDOOR STORAGE 460 SF / 300 = 1.5 TOTAL OUTDOOR 23.2 OCC GRAND TOTAL 110 OCC TOTAL OCCUPANT LOAD OF PREVIOUS PERMIT 99 OCC BLDG-3651-2019 < 20% INCREASE PLUMBING CALCULATIONS PLUMBING OCCUPANCY CALCS (PER 2022 CPC TABLE 422.1): A-2 SPIRIT TASTING 2,437 SF / 30 OLF = 81.2 A-2 OUTDOOR PATIO 325 SF / 30 OLF = 10.8 S-2 STORAGE PATIO 460 / 4,000 OLF = 0.1 TOTAL 92 (46 M / 46 F) REQUIRED PROVIDED ** WATER CLOSETS 1 M / 2 F (E) 2 PUBLIC SHARED * URINAL 1 M (E) N/A, SHARED LAVATORIES 1 M / 1 F (E) 2 PUBLIC SHARED * DRINKING FOUNTAIN 1 N/A (WATER SERVICE) SERVICE SINK 1 1 A-2 FOOD PREP 1,175 SF / 50 OLF = 23.5 S-2 STORAGE (E)1,300 SF / 4,000 = 0.3 TOTAL 24 (12 M / 12 F) REQUIRED PROVIDED ** WATER CLOSETS 1 M / 1 F (E) 1 EMPLOY SHARED URINAL 1 M (E) N/A, SHARED LAVATORIES 1 M / 1 F (E) 1 EMPLOY SHARED DRINKING FOUNTAIN 1 N/A, KITCHEN SERVICE SINK 1 1 * PER CPC 422.2 EX (4), SEPARATE FACILITIES SHALL NOT BE REQUIRED WHERE ROOMS HAVE FIXTURES DESIGNED FOR USE BY ALL GENDERS AND THE WATER CLOSETS ARE INSTALLED IN PRIVACY COMPARTMENTS. EACH COMPARTMENT SHALL BE LOCKABLE FROM THE INSIDE OF THE COMPARTMENT, WITH A DOOR LOCKING DEVICE THAT IS READILY DISTINGUISHABLE AS LOCKED FROM THE OUTSIDE OF THE COMPARTMENT * PER CPC 422.2.2, WHERE A SEPARATE TOILET FACILITY IS REQUIRED FOR EACH SEX, AND EACH TOILET FACITY IS REQUIRED TO HAVE ONLY ONE WATER CLOSET, TWO FAMILY OR ASSISTED-USE TOILET FACILITIES SHALL BE PERMITTED IN PLACE OF THE REQUIRED SEPARATE TOILET FACILITIES ** PER CEBC 1009.1, EXCEPTION: ONLY WHERE THE OCCUPANT LOAD OF THE STORY IS INCREASED BY MORE THAN 20 PERCENT, PLUMBING FIXTURES FOR THE STORY SHALL BE PROVIDED IN QUANTITIES SPECIFIC IN THE CPC BASED ON THE INCREASED OCCUPANT LOAD ISA X TX F O SHEET NOTES 1. WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY WITH CBC 11B-902. DINING SURFACES REQUIRED TO BE ACCESSIBLE SHALL BE DISPERSED THROUGHOUT THE SPACE INCLUDING EACH TYPE OF SEATING IN AN AREA, CBC 11B-226.2 2. TABLES ACCESSIBLE TO WHEELCHAIR USERS SHALL HAVE A MAXIMUM HEIGHT OF 34" AND MUST ACCOMMODATE A 30"X48"CLEAR FLOOR SPACE. THE SPACE BENEATH EACH TABLE FOR LEG ROOM SHALL BE MINIMUM 19" DEEP, 30" WIDE AND 27" HIGH, MEASURED FROM THE FINISHED FLOOR LEVEL. 3. PANIC BARS TO BE PROVIDED ON EXTERIOR DOORS PER 1010.2.9 CBC; CONTRACTOR TO V.I.F. REPAIR AND REPLACE AS NEEDED. 4. ACCESSIBLE PATHS OF TRAVEL / EXIT DISCHARGE ROUTE SHALL NOT HAVE A RUNNING SLOPE STEEPER THAN 1:20 AND A CROSS SLOPE STEEPER THAN 1:48 PER CBC 11B-403.3 5. ALL EMERGENCY LIGHTING TO HAVE A BATTERY BACK UP OPTION OR SIMILAR METHOD FOR OUTAGES PER 1008 CBC. REFER TO ELECTRICAL SHEETS FOR EMERGENCY LIGHTING LOCATIONS. A BUILDING AREA (NO CHANGE TO FOOTPRINT): A-2 SPIRIT TASTING = 3,018 SF A-2 FOOD PREP = 1,678 SF S-2 STORAGE = 1,300 SF GROSS TOTAL AREA = 5,996 SF 1 1 27'-3" 55 ' - 9 " 3 A3.1 A D 1 1 1 A4.1 2 A4.1 2 3 4 B 3 4 48'-0"24'-0" 20 ' - 9 " 35 ' - 0 " 20'-9116"24'-0" 1 2 3 5 6 7 1 2 5 6 4 3 1 (E) BATH (E) BATH (E) HALL (R) UTILITY 10'-0" x 7'-7" (R) COLD STORAGE (R) SPIRIT TASTING 8 9 10 11(N) EMPLY. HALL (R) SPIRIT TASTING 12 14 15 15 SUITE 130 +34 H +36 H +34 H +42 H +36 H 16 CAB 17 8 15 9 16 10 11 12 13 14 10 11 12 17 18 (R) PRODUCTION RYAN M BROCKETT C-32384 REN 12 31 27 LI CE N S E D ARCHI T E C T S T A T E OF A L I F O RNIA C DATE ISSUE OW N E R / 34 2 7 R O B E R T O L L C 18 9 C O U N T R Y S I D E L N SA N L U I S O B I S P O , C A 9 3 4 0 1 THESE DOCUMENTS INCLUDE ORIGINAL WORK, INSTRUMENTS OF SERVICE, AND INTELLECTUAL PROPERTY OF RYAN BROCKETT ARCHITECT INC. THE DESIGN AND INFORMATION REPRESENTED IN THESE DRAWINGS ARE SOLELY FOR USE WITH THIS PROJECT AND SHALL NOT BE TRANSFERRED OR OTHERWISE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. 05.15.25 PERMIT 07.25.25 RESUBMIT 1 08.18.25 RESUBMIT 2 08.25.25 RESUBMIT 3 02.17.26 REVISION 34 2 7 R O B E R T O C T , S A N L U I S O B I S P O , C A 9 3 4 0 1 AP N / 0 5 3 - 0 6 3 - 0 1 9 20 2 5 B R O C K E T T A R C H I T E C T S / I N T E R I O R S C N SCALE: 1/4" = 1'-0" 042181 PROPOSED FLOOR PLAN / WEST PROPOSED FLOOR PLAN WEST A2.3 SHEET LEGEND SHEET NOTES EQUIPMENT LIST 1 2 3 4 5 6 7 8 KEYNOTES 01 (N) PONY WALL, TYP. 02 (E) FLOOR DRAIN 03 (N) 3'-0" X 6'-8" DOUBLE-SWINGING DOOR 04 (N) SHELVING 05 (N) 34" H LOWER CASEWORK & COUNTERTOP FOR EMPLOYEE AND CUSTOMER USE, PROVIDE MIN 30" X 48" CLEAR FLOOR SPACE FOR ADA APPROACH, SHOWN DASHED 06 (N) PASS-THRU WINDOW 07 (N) LINE OF SOFFIT ABOVE SHOWN DASHED, TYP. 08 (E) LINE OF SOFFIT ABOVE SHOWN DASHED, TYP. 09 (E) COLUMNS TO REMAIN, TYP. 10 (E) EXTERIOR AWNINGS TO REMAIN, TYP. 11 (N) BUILT-IN STORAGE CABINET 12 (E) CONCRETE FLOORING TO REMAIN THROUGHOUT, GRIND AND SEAL AS REQUIRED CONTRACTOR TO V.I.F. 13 (N) SELF-SERVE GLASS AND WATER BOTTLE FILL STATION; PROVIDE MIN 30" X 48" CLEAR FLOOR SPACE FOR ADA APPROACH SHOWN DASHED, SEE DETAIL 7/A7.2 FOR ACCESSIBLE REACH RANGES, VFY MIN 15" TO MAX 48" AFF 14 (N) SODA MACHINE; PROVIDE MIN 30" X 48" CLEAR FLOOR SPACE FOR ADA APPROACH SHOWN DASHED, SEE DETAIL 7/A7.2 FOR ACCESSIBLE REACH RANGES, VFY MIN 15" TO MAX 48" AFF 15 (N) 8' x 7'-2"AWNING WINDOW WITH FIXED PANES ABOVE, TYP. 16 (N) 36" H LOWER CASEWORK & COUNTERTOP WORKSTATION FOR EMPLOYEE USE ONLY 17 (N) EXTERIOR WALL MOUNTED COMPLIANT FIXED ROOF ACCESS LADDER W/ PLATFORM AND RAIL EXTENSIONS AS REQ'D; MIN. 16" CLR BETWEEN RAILS, MIN. 15" CLR FROM FIXED OBJECTS ECOLAB GLASS WASHER, MODEL NO. ES4000 EXISTING MOP SINK HAND SINK BY GSW USA, 15 3/4 " x 15 1/4" x 13 3/8'", MODEL NO. HS-1615S NOT USED BEVERAGE REFRIGERATOR, 60" x 29 1/2" x 78 5/8" BY TRUE MODEL NO. GDM-49-HC~TSL01 BEVERAGE REFRIGERATOR, 60" x 29 1/2" x 78 5/8" BY TRUE MODEL NO. GDM-49-HC~TSL01 SODA MACHINE OWNER SUPPLIED, SPEC TBD. DISTILLING SYSTEM EQUIPMENT FILLER & DRAINBOARD, MODEL NO. KR24-DR90 LIQUOR DISPLAY, MODEL NO. KR24-12RD UNDERBAR ICE BIN, MODEL NO. KR19-24-10 MIXOLOGY SINK, MODEL NO. KR24-MS12 3-COMPARTMENT SINK, MODEL NO. KR24-53C-PE FILLER & DRAINBOARD, MODEL NO. KR19-C24L-PE BACK BAR COOLER, MODEL NO. SD60L BACK BAR COOLER, MODEL NO. SD60R FROSTER/CHILLER, GLASS/MUG/PLATE, MODEL NO. FMC24 ICE MACHINE, MODEL NO. F-330BAJ-C 9 10 1. REFER TO FLOOR PLAN GENERAL NOTES ON SHEET T2.1 2. FLOOR PLAN DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF DOOR, WINDOW OR FIXTURE, UNLESS OTHERWISE NOTED. 3. CONTRACTOR TO VERIFY LAYOUT, ROUGH FRAMING AND FINISH DIMENSIONS WITH INTERIOR DOOR AND FINISH SELECTIONS. 4. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES. 5. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED. 6. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS, PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING. 7. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING. 8. WHERE THRESHOLDS ARE REQUIRED, PROVIDE ACCESSIBLE THRESHOLDS WITH MAXIMUM 1/2" ELEVATION CHANGE. 9. REFER TO DETAILS ON A7.1 & A7.2 FOR ACCESSIBILITY DETAILS, REACH RANGES, AND CLEAR SPACE REQUIRED. 10. ALL EQUIPMENT ON CASTERS TO BE ATTACHED BACK TO THE STRUCTURE TO PREVENT MOVEMENT PER 918.6 CMC. (E) WALLS TO REMAIN (N) 2X WD FRAMED WALL (E) AREA NOT IN SCOPE 11 12 13 14 15 16 17 18 Attachment C - USE-3598-2016 Approval Letter