Loading...
HomeMy WebLinkAbout09-03-2026 Inspection-Letter 2160 Santa Barbara Avenue, San Luis Obispo, CA 93401   Phone: (805) 783 - 7775 Fax: (805) 543 - 8019 Fire Department Email: FDGeneral@slocity.org    Hours: Monday - Friday, 8:00 am - 5:00 pm Business / Occupant:THE VILLAGE AT SYDNEY CREEK Address:1234 Laurel Work Phone: Contact Name:,Email: Date Completed:Inspected By:Hutchinson, Julianna Passed:Violation Count:5 San Luis Obispo City Fire Inspection Report Fire Department Information Business / Occupant Information Inspection Information Thank you for your cooperation with San Luis Obispo City Fire in keeping your business and our community safe! Correct the cited violation(s) by the "Reinspection Date" listed below to avoid further enforcement action including, but not limited to, chargeable re-inspection and/or Administrative Citation. You may request a review of the cited violations by the Department Director [Fire Chief ] within 5 days of report issuance if noted violations do not create an immediate danger to health and safety (SLO M.C. 1.24.090). If you have any questions, please contact our Inspection Line at 805/783-7775. Inspection Notes: Violations Code Description Comments Reinspection Date 705.2 Inspection and maintenance. Opening protectives in fire- resistance-rated assemblies shall be inspected and maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and Remove doorstops from all fire-rated doors. These doors are intended to remain closed to prevent the spread of smoke and fire unless held open by an approved device that operates with the fire alarm system. 09/03/2026 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $271 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court.Page 1 of 4 draft control doors shall not be modified. 1010.2.13.1 Delayed egress locking system. The delayed egress locking system shall be installed and operated in accordance with all of the following: 1.The delay electronics of the delayed egress locking system shall deactivate upon actuation of the automatic sprinkler system or automatic fire detection system, allowing immediate, free egress. 2.The delay electronics of the delayed egress locking system shall deactivate upon loss of power controlling the lock or lock mechanism, allowing immediate free egress, to any one of the following: 2.1.The egress-control device itself. 2.2.The smoke detection system. 2.3.Means of egress illumination as required by Section 1008. 3.The delayed egress locking system shall have the capability of being deactivated at the fire command center and other approved locations. 4.An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware for not more than 3 seconds. Initiation of the irreversible process shall activate an audible signal in the vicinity of the door. Once the delay electronics have been deactivated, rearming the delay electronics shall be by manual means only. The time delay established for each egress-control device shall not be field adjustable. For applications listed in Section 1.9.1 regulated by the Division of the State Architect—Access Compliance, see Chapter 11B. Exception: In facilities housing Alzheimer’s or dementia clients, a delay of not more than 30 seconds is Add/replace signage on delayed egress doors to indicate their operation, and place signage on locked exit doors indicating a member of staff is required to operate them in an emergency. 09/03/2026 *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $271 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court.Page 2 of 4 permitted on a delayed egress door. 5.The egress path from any point shall not pass through more than one delayed egress locking system. Exceptions: 1.In Group R-2.1, Group I-2 or I-3 occupancies, the egress path from any point in the building shall pass through not more than two delayed egress locking systems provided that the combined delay does not exceed 30 seconds. 2.In Group I-4 occupancies, the egress path from any point in the building shall pass through not more than two delayed egress locking systems provided that the combined delay does not exceed 30 seconds and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. 6.A sign shall be provided on the door and shall be located above and within 12 inches (305 mm) of the door exit hardware: Exception: Where approved, in Group I occupancies, the installation of a sign is not required where care recipients who, because of clinical needs, require restraint or containment as part of the function of the treatment area. 6.1.For doors that swing in the direction of egress, the sign shall read: “PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 [30] SECONDS.” 6.2.For doors that swing in the opposite direction of egress, the sign shall read: “PULL UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 [30] SECONDS.” 6.3.Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm). 6.4.A tactile sign shall also be provided in Braille and raised characters, which complies with Chapter 11B. 7.Emergency lighting shall be provided on the egress side of the door. *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $271 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court.Page 3 of 4 8.The delayed egress locking system units shall be listed in accordance with UL 294. 9.Actuation of the panic bar or other door-latching hardware shall activate an audible signal at the door. 10.The unlatching shall not require more than one operation. 11.Regardless of the means of deactivation, relocking of the egress-control device shall be by manual means only at the door. 603.2.2 Open electrical terminations. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Replace missing exterior outlet covers. 09/03/2026 1013.3 Illumination. Exit signs shall be internally or externally illuminated. Exception: Tactile signs required by Section 1013.4 need not be provided with illumination. Repair the lower illuminated exit sign in the Bishop House hallway and replace the missing self- luminous exit sign from one side gate. 09/03/2026 1008.1 Means of egress illumination. Illumination shall be provided in the means of egress in accordance with Section 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Repair the illuminated exit lighting in the Bishop House hallway where one of the bulbs is falling off. 09/03/2026 Inspection Documents Violation Documents *Please note: If a third inspection is required due to non-compliance, a fire-inspection fee of $271 may be charged for that inspection, and every inspection thereafter until compliance is obtained. Failure to comply may result in a misdemeanor citation and an appearance by you in court. Page 4 of 4