HomeMy WebLinkAbout2023.10.18_ARCH-0464-2023 (2932 Augusta) Completeness Letter v1 October 18, 2023 Sent via Email Aisling Burke Ten Over Studio 539 Marsh St San Luis Obispo, CA 93401 Subject: Completeness Review #1 – ARCH-0464-2023 (2932 Augusta St.) Multi-Family Residential Development, ADU, and Parking Lot Dear Aisling Burke: Thank you for the September 20th submittal requesting a Moderate Development Review to allow for development of a 16,133-square-foot, 3-story, 23-unit multi-family residential building, a 1,619-square-foot, 1-story, 2-unit accessory dwelling unit (ADU) building, and a 25-space surface parking lot. We have reviewed your application and found it to be incomplete. We will be unable to process your application until additional information and/or revisions have been submitted, to the satisfaction of the Community Development Director. Preliminary review is necessary to ensure that staff has adequate information to evaluate your project and identify any conflicts with City standards or guidelines. The purpose of this letter is to provide you with a list of items that need to be addressed prior to taking action on your project. Preliminary review indicates that your application will remain in an incomplete status until the following information and/or revisions are submitted: Note: Upon resubmittal, please provide a narrative indicating where responses to these items can be found on plans. Department comments/completeness items: Planning Division - Community Development Department 1. Building Square Footage. Based on the project plan set and project description (dated August 28, 2023) the project includes development of a 16,133-square-foot multi-family residential building. However, on Sheet L1.0 of the project site plans it indicates that the multi-family residential building is 17,000 square feet in size. Please rectify this discrepancy. 2. Maximum Residential Density. Based on Section 17.70.040 of the City Zoning Regulations, one-bedroom dwellings less than 600 square feet in size have a density unit value of 0.50 unit and one-bedroom dwellings between 601 and 1,000 square feet in size ARCH-0464-2023 (2932 Augusta St.) Completeness Review #1 October 18, 2023 Page 2 have a density unit value of 0.66 unit. Based on the project plan set (dated August 28, 2023), the project includes 7 units between 601 and 1,000 square feet in size and 16 units less than 600 square feet in size. Based on the proposed units of the multi-family residential building, the proposed residential density of the project would be 26.29 units per acre (12.62 units divided by the 0.48-acre site). This residential density is in exceedance of the Maximum Residential Density of 24 units per net acre as set forth in the R-4 Development Standards (City Zoning Regulations Section 17.22.020). Please revise the project plan set to demonstrate consistency with the Maximum Residential Density standards for projects located in the R-4 zone. 3. Retaining Walls Dimensions. Based on the project plan set (dated August 28, 2023), the project includes construction of two retaining walls, one along the east side of the property and one along the west side of the property. While the location and cross sections of these walls are provided in the plan set, it is not clear what the total length or maximum height of these walls are. Please provide the dimensions of these proposed walls to demonstrate compliance with City Zoning Regulations Section 17.70.070 (Fences, Walls, and Hedges). 4. Demolition of Existing Structure. The project includes demolition of the existing church structure located on-site. Please provide documentation indicating the year this structure was built and if over 50 years old, provide documentation regarding its potential to be a historic resource (refer to Building Construction and Fire Prevention Code within Chapter 15.04 of the Municipal Code Appendix E – Demolition and Moving of Buildings). 5. Tree Removal. Based on observations of the project site and aerial imagery, the project site currently supports existing landscaped vegetation. Please provide additional information to clarify whether the project would result in removal of any trees located on-site, and if so, the diameter at standard height (DSH) and type of trees to be removed in order to demonstrate compliance with Section 12.24.090 of the City Municipal Code. 6. Infill Development Design Compatibility. In accordance with Section 5.3 (Residential Project Design, Infill Development), the proposed project buildings should be compatible in scale, siting, detailing, and overall character with adjacent buildings and those in the immediate neighborhood. In addition, this section also states that color schemes for infill residential structures should consider the colors of existing houses in the neighborhood to maintain compatibility and multi-family structures should be set back from adjacent public streets consistent with the prevailing setback pattern of the immediate neighborhood. Please provide additional information and/or exhibits to demonstrate consistency with these design guidelines. Additional Comments – These comments are not completeness comments but are provided for further context and may directly affect the staff recommendation. 7. Pedestrian Safety/Exterior Lighting. Based on the project plan set, it appears that the entries to the first-floor units may pose some safety concerns based on the long narrow hallways with high walls, one-way access, and no exterior lighting shown. Please consider providing ARCH-0464-2023 (2932 Augusta St.) Completeness Review #1 October 18, 2023 Page 3 additional information and/or modifications to the site/building design to make that space safer for someone walking to their unit during nighttime hours. If you have any questions on the above planning comments, or any questions regarding this letter, please contact me at 805-539-2867 or cassidy.bewley@swca.com. Housing – Community Development Department 8. Demonstrate how the project will meet the inclusionary affordable housing requirement, in accordance with Municipal Code Section 17.138.070, and as identified on the application checklist. a. If the project is to use the in-lieu fee option, please provide calculations to identify the estimated in-lieu fees. Preliminary calculations estimate an in-lieu fee of $245,860. b. If affordable units are to be provided within the project, please identify the specific units intended to be dedicated and the specific income levels of each unit (low-, moderate-income, etc.). If you have questions on the above items, please contact Housing Programs Coordinator, Kyle Bell, 805-781-7524, or by e-mail: kbell@slocity.org. Building Division – Community Development Department 9. This project is considered a covered multi family dwelling and therefore all units shall be on an accessible route. Per the building code this project is (1) R-2 occupancy and labeling the last two units as ADUs works for a planning aspect, but not through the 2022 California BLDG code. I can see through elevation views that this BLDG may depend on this slope on elevation views and an unreasonable hardship can be considered. Please reach out to me and see if we can get your project to comply with 11A and get your BLDG the way you want it. See below screen shots for issues.(11A-1110A.1) ARCH-0464-2023 (2932 Augusta St.) Completeness Review #1 October 18, 2023 Page 4 10. The wall and opening will have to be protected at the below marked up area for egress purposes. 11. Please provide the percentage of wall openings on (North, East, West) elevations. (705.8 CBC) 12. Please demonstrate compliance with max balcony square footage. (705.2.3.1 CBC) If you have questions on the above items, please contact Plans Examiner, Sean McCaffrey, 805-781- 7168, or by e-mail: smccaffr@slocity.org. Utilities Department 13. Clarify the square footage of landscaping proposed as part of the project. If greater than 500 square feet, provide a Maximum Applied Water Allowance calculation as required by the Water Efficient Landscape Standards (Section 17.70.220 of the City’s Municipal Code). 14. Contact San Luis Garbage Company (SLG) and obtain in writing that the proposed enclosures and collection method meets the SLG requirements. SLG also need to confirm truck access and clearances needed to reach the discarded materials containers. Note only: The building permit submittal shall demonstrate compliance with fire flow and fire sprinkler requirements for all floors of the proposed project. Design plans shall be supported by engineering calculations to be submitted with the building permit. Determination of requirements at this time is recommended, such that any potential modifications to the floor plan(s) can be addressed. If you have questions on the above items, please contact Utilities Special Projects Manager, Shawna Scott, 805-781-7176, or by e-mail: sscott@slocity.org ARCH-0464-2023 (2932 Augusta St.) Completeness Review #1 October 18, 2023 Page 5 Fire Department 15. Provide a minimum 26 foot wide, unobstructed, ladder truck access lane to within 15-30 foot of building. 16. Show locations of all existing or proposed fire hydrants within 300 feet of the furthest exterior wall. 17. Show location of fire sprinkler lateral, backflow device, fire department connection, and fire sprinkler riser room. 18. A maximum of 2 DETACHED ADUs are allowed for existing multi-family sites or conversion of existing floor area. This is neither an existing multi-family building and the proposed ADUs are not detached and provided with the minimum Fire Separation Distance (FSD) on all sides to property lines or implied property lines between buildings. If you have questions on the above items, please contact Fire Marshal, Rodger Maggio, 805-781- 7386, or by e-mail: rmaggio@slocity.org Transportation Division – Public Works Department 19. Per City/State Fire Code, a three-story building will require a 26’ clear fire access road to the building. Augusta Street currently provides 20’ clear width with (36’ curb to curb + 8’ parking lane on both sides). Please confirm how site access will comply with Fire Code. 20. Please confirm that proposed parking bay dimensions meet minimum by widths per City Engineering Standard 2240. Also, see City Eng. Std. 2230 regarding provisions for compact parking stalls. Suggest discussing with City Planner to confirm approach to compact vs. standard parking stalls with project proposal. 21. Please confirm that proposed long-term bicycle parking room (62 stalls) can be feasibly designed in conformance with City Active Transportation Plan (ATP) Design Guidelines. See ATP Appendix C, page 20 for details. Specifically, consider design policies 7.26-7.30, which require no more than 50% of indoor bicycle parking to be provided via vertical hanging racks, and require accommodations for larger bicycles (cargo and recumbent bikes). If you have questions on the above items, please contact Transportation Manager, Luke Schwartz, 805-781-7190, or by e-mail: lschwart@slocity.org. The above list includes all of the items initially identified as necessary for us to certify your application as complete. The City may ask for additional information upon more detailed review of your project. If you have any questions regarding this letter or the specific items necessary to submit for a complete application, please contact me at (805) 539-2867. ARCH-0464-2023 (2932 Augusta St.) Completeness Review #1 October 18, 2023 Page 6 Sincerely, Cassidy Bewley | She, her, hers Project Manager / Enviornmental Planner SWCA Environmental Consultants 3426 Empresa Drive, Suite 100 San Luis Obispo, CA 93401 P 805.539.2867