Loading...
HomeMy WebLinkAbout05/16/2006, C3 - WATER RECLAMATION FACILITY DIGESTER #2 - REPAIR & PAINT SPECIFICATION NO. 90611B. Council IMS 05/16/2006 j agenda Repoizt '-N— C3 CITY OF SAN LUIS OBIS,,,,//PllO FROM: Jay Walter, Public Works Direct /613 Prepared By: Daniel Van Beveren, enior Civil Engineer ? SUBJECT: WATER RECLAMATION FACILITY DIGESTER#2—REPAIR & PAINT SPECIFICATION NO. 90611B. CAO RECOMMENDATION 1. Approve plans and specifications for "Water Reclamation Facility Digester#2 Repair& Paint, Specification No. 90611B." 2. Authorize staff to advertise for bids and authorize the CAO to award the contract if the lowest responsible bid is within the engineer's estimate of$150,000. DISCUSSION Routine maintenance work is performed on each of the digesters at the Water Reclamation Facility approximately every 5 to 10 years. This year, maintenance work for Digester#2 is proposed to be done through two distinct construction contracts. The first phase was approved by the CAO within his purchasing authority on April 19, 2006 and includes the "empty and clean" portion of the project. That project is currently being advertised, and the work is scheduled for June of this year. The second phase of work, the "repair and paint" portion, will commence once phase one of the project is completed. This Council Agenda Report is specific to the "repair and paint" portion of the work. Digester #2 is a concrete tank approximately 14 feet high, and 50 feet in diameter. An assortment of pipes, pumps, valves, ports, and other miscellaneous plumbing equipment is located on the roof of the digester, and additional equipment is located in the digester's interior. Typical with any digester maintenance project, the major scope of work on this project includes the repair and recoating of the internal and external concrete surfaces on the digester, and the repainting of external plumbing equipment. Maintenance projects such as this one help to protect the digester from the harsh environment at the water reclamation facility, thereby increasing its service life and deferring the need for more costly major facility replacements. One component of this year's maintenance project is the installation of a new protective railing around the perimeter of the digester roof, an area frequently accessed by maintenance workers. This railing will increase the safety of the workers, and is necessary to bring the digester up to the current requirements of the California Uniform Building Code. CONCURRENCES The Community Development Department has given this project a categorical exemption. U Water Reclamation Facility_Digester#2 Repair and Paint,Spec.90611 B Page 2 FISCAL IMPACT The 2005-07 Financial Plan identifies $215,000 for Digester#2 Clean and Repair. Total Project Budget $215,000 Phase 1: Empty and Clean (estimate) <$50,000> Phase 1: Empty and Clean (contingencies &misc. costs) <$6,000> Amount Remaining for Phase 2: Digester#2 Repair& Paint $159,000 Engineer's Estimate for Digester#2 Repair&Paint: $150,000 Contingencies: $7;500 Misc. Project Costs $1;500 Total: $159,000 ALTERNATIVES AVAILABLE FOR REVIEW IN THE COUNCIL OFFICE Special Provisions for Digester#2 Repair and Paint. I:\_CAR Reports\2006\CIR90611 WRF Digester#2\90611 B adv.doc