Loading...
HomeMy WebLinkAbout04-06-2015 ARC Item 1 - 323 and 353 Grand Avenue ARCHITECTURAL REVIEW COMMISSION AGENDA REPORT SUBJECT: Continued review of plans for four new single-family residences and associated site improvements. PROJECT ADDRESS: 323/353 Grand Avenue BY: Marcus Carloni, Associate Planner Phone Number: (805) 781-7176 e-mail: mcarloni@slocity.org FILE NUMBER: ARC 25-13 FROM: Phil Dunsmore, Senior Planner RECOMMENDATION Adopt the Draft Resolution (Attachment 1) which approves the project, based on findings, and subject to conditions. SITE DATA Applicant Ryan Petetit, John Belsher, PB Companies Representative Steve Rigor, Arris Studio Architects Submittal Date March 9, 2015 Complete Date March 17, 2015 Zoning R-1 (Low-Density Residential) General Plan Low Density Site Area 0.53 Acres (23,132 square feet) Environmental Status Negative Declaration adopted by Planning Commission (ER 25-13) on August 14, 2013. SUMMARY On January 21, 2015 the ARC reviewed the proposed project to construct four single-family residences at the subject location. At that hearing, staff noted conflicts with parking and driveway standards and a conflict with the Community Design Guidelines with regard to the size/scale of the four proposed in-fill residences as they relate to the existing neighborhood. Ultimately, the ARC continued the project with direction to revise the on-site circulation and reduce the size/scale of the proposed residences [see section 4.0 below]. The applicant has revised the project in response to ARC direction. Staff finds the applicant’s efforts to reduce the size/scale of the proposed residences and modify the site circulation to comply with ARC direction as discussed in section 4.0 below. The reduction in size/scale and use of quality finish materials that are found in the vicinity demonstrate the projects compatibility with the Meeting Date: April 6, 2015 Item Number: 1 ARC1 - 1 PJD ARC 25-13 (323/353 Grand Avenue) Page 2 existing neighborhood, consistent with the Community Design Guidelines. 2.0 COMMISSION’S PURVIEW The ARC’s role is to review the project in terms of its consistency with ARC direction, the Community Design Guidelines, and applicable City standards. 3.0 PROJECT INFORMATION 3.1 Site Information/Setting The project site encompasses two parcels; 323 Grand Avenue (12,032.63 square feet) and 353 Grand Avenue (11,099.33 square feet). The project site is located on the west side of Grand Avenue between McCollum and Fredericks Streets. The two parcels are in the Low-Density Residential (R-1) zone and are encompassed by R-1 zoning with single-family residences. The project site is gently sloping (approximately 4% average cross slope) and is developed with two single-family residences (to be demolished); one per parcel. Each parcel has a driveway providing access from Grand Avenue and minimal other improvements. Attachment 2, Project Plans, Sheet A0.2 illustrates the sites existing conditions (structures, trees, hardscape). Site Size ~23,000 square feet Present Use & Development Two R-1 parcels with one single-family residence each Topography Flat: ~4 percent cross slope Access Grand Avenue Surrounding Use/Zoning North: Single-Family Residence (R-1 zone) South: Single-Family Residence (R-1 zone) East: Grand Avenue + Single Family Residences (R-1 zone) West: Single Family Residences (R-1-Planned Development zone) 3.2 Project Description The proposed project includes the following significant features (Attachment 2, Project Plans): 1. Construction of four detached single-family residences (two story homes): a. Lot 1: 1,995 square foot1 4-bedroom, 3-bath residence b. Lot 2: 2,379 square foot1 4-bedroom, 4-bath residence c. Lot 3: 2,364 square foot1 4-bedroom, 3-bath residence d. Lot 4: 1,963 square foot1 4-bedroom, 3-bath residence 2. Common access driveway (porous pavers) providing access to lots 2, 3, and 4 with guest parking spaces. 3. Tree removals. No removal of heritage trees (Attachment 6, Existing Site Plan, indicates tree types and sizes). The City Arborist supports tree removals that are within the footprint of the proposed residences. Trees outside of the footprints and access way need 1 The square footage calculation does not include garages (502 square foot average size) or porch/decks (294 square foot average size). ARC1 - 2 ARC 25-13 (323/353 Grand Avenue) Page 3 to be maintained to the maximum extent feasible or approved for removal by the Tree Committee. 4. Craftsman architectural style: a. Horizontal siding (4 or 6-inch siding) with decorative wainscoting (8-inch siding) and board and batten gable accenting with wood outlookers. b. Covered porches with tapered columns and brick bases. 3.3 Project Statistics Item Proposed 1 Ordinance Standard 2 Street Yard Setback 20 feet 20 feet Other Yard Setback (sides and rear) Compliant Varied Max. Height of Structure(s) 24’-6” feet 25 feet Building Coverage (footprints) ~31% average 40% Parking Spaces Lot 1 2 (plus guest spaces) 2 Parking Spaces Lots 2, 3, 4 3 3 (due to access from flag lot) Notes: 1. Applicant’s project plans 2. City Zoning Regulations 3.3 Background For background on the Planning Commission’s August 14, 2013 approval of the four-lot subdivision see the January 21, 2015 ARC Staff Report (Attachment 4). 4.0 PROJECT ANALYSIS The ARC reviewed the subject project on January 21, 2015 and ultimately continued the project with direction to the applicant on revisions to the site plan and size of the proposed residences. The following discusses the applicant’s revisions to the project in response to ARC direction. 4.1 ARC Directional Items 1. Provide a vehicle circulation plan that provides adequate and safe vehicle circulation for compliance with the Parking and Driveway Standards. a. Increase the common access way width to allow adequate backup space for vehicles using all parking spaces (24-feet minimum). b. Increase the driveway depth for lot 2 in order to allow vehicles to park in the driveway without overlapping the common access way (18-feet, 5-inches minimum). c. Provide adequate circulation for the guest space on lot 3 (allowing a vehicle to exit the site in a forward motion with no more than two maneuvers). d. Reduce the depth of the guest spaces on lots 2 and 3 to discourage tandem parking that will overlap into the common access way. Staff Response: Consistent with ARC direction, the applicant has widened the common access way and modified the parking spaces as directed in items 1a through 1d above (Attachment 2, Project Plans, Sheet A-0.1). Additionally, the Engineering ARC1 - 3 ARC 25-13 (323/353 Grand Avenue) Page 4 Division has included conditions of approval (condition #7) to further improve site circulation. Conditions include removing the parallel parking space from lot 1 (to be replaced with landscaping), adding an additional space between lots 3 and 4, and lengthening the guest parking spaces between lots 1/2 and 3/4. These modifications to the site plan ensure compliance with the Parking and Driveway Standards and will be subject to the final approval of the Community Development Director. 2. Lots 1 and 4: Reduce the overall square footage and mass of the proposed residences (to approximately 2,000 square feet) for compatibility with the scale of existing adjacent residences fronting Grand Avenue and for lowered development intensity on these sub- 6,000 square foot parcels. 3. Lots 2 and 3: Reduce the overall square footage and mass of the proposed residences (to approximately 2,400 square feet) for compatibility with the scale of the existing adjacent Leroy Court Planned Unit Development and for lowered development intensity on these sub-6,000 square foot parcels. 4. The reduction in square footage/scale of the proposed residences shall maintain similar building footprints and provide reduced size upper floor areas. Staff Response to Directional Items 2, 3, & 4: Consistent with ARC direction, the applicant has reduced the overall square footage of the residences on lots 1 and 4 (now 1,995 s.f. and 1,963 s.f. respectively) and the residences on lots 2 and 3 (now 2,379 s.f. and 2,364 s.f. respectively). Square footage was mainly removed from upper floors (see Attachment 2, Project Plans, Sheets A-1.0, A-2.0, A-3.0, & A-4.0, “Areas”) which results in increased articulation of the upper floors and a reduction in massing for compatibility with the neighborhood. The proposed revisions comply with ARC directional items 2, 3, and 4. 5. Provide a monument sign positioned to be clearly visible from Grand avenue and showing the address of each building (Fire Department code requirement). Staff Response: The applicant has provided a design for a small monument sign to be located adjacent to the common access way. Staff supports the conceptual design as compatible with the design of the project and has included a condition of approval which allows the Director to approve the final design and location of the sign along with plans submitted for a construction permit. The condition ensures that the monument sign will include subtle illumination for compatibility with the residential neighborhood. 5.0 OTHER DEPARTMENT COMMENTS Comments from the other departments have been incorporated into the recommended resolution as conditions of approval and/or code requirements. 6.0 ALTERNATIVES & RECOMMENDATION 6.1 Deny the project based on findings of inconsistency with ARC direction, the Community ARC1 - 4 ARC 25-13 (323/353 Grand Avenue) Page 5 Design Guidelines, and applicable City requirements. 6.2 Continue the project to a date uncertain with the directional items 7.0 ATTACHMENTS 1. Draft Resolution 2. Project Plans (Revised) 3. ARC Minutes (January 21, 2015) 4. Previous ARC Staff Report (January 21, 2015) 5. Previous Plans (January 21, 2015) 6. Existing Site Plan Included in Commission member portfolio: project plans Available at ARC hearing: color/materials board ARC1 - 5 RESOLUTION NO. ####-15 A RESOLUTION OF THE SAN LUIS OBISPO ARCHITECTURAL REVIEW COMMISSION APPROVING PLANS FOR FOUR NEW SINGLE-FAMILY RESIDENCES AND ASSOCIATED SITE IMPROVEMENTS (NEGATIVE DECLARATION OF ENVIRONMENTAL IMPACT APPROVED BY PLANNING COMMISSION ON AUGUST 14, 2013), AS REPRESENTED IN THE STAFF REPORT AND ATTACHMENTS DATED APRIL 6, 2015 (323/353 GRAND AVENUE, R-1 ZONE, ARC 25-13) WHEREAS, on April 6, 2015, the Architectural Review Commission of the City of San Luis Obispo conducted a public hearing in the Council Chamber of City Hall, 990 Palm Street, San Luis Obispo, California, for the purpose of design review for four new single-family residences and associated site improvements (the “Project”) instituted under ARC 25-13, PB Companies (“Applicant”); and WHEREAS, the Architectural Review Commission of the City of San Luis Obispo has duly considered all evidence, including the testimony of the applicant, interested parties, and evaluation and recommendations by the staff at said hearings. WHEREAS, notices of said public hearings were made at the time and in the manner required by law; and NOW, THEREFORE, BE IT RESOLVED by the Architectural Review Commission of the City of San Luis Obispo as follows: SECTION 1. Findings. The Architectural Review Commission hereby grants approval to the project (ARC 25-13), based on the following findings: 1. That the Project will not be detrimental to the health, safety, or welfare of those working or residing in the vicinity since the proposed project is consistent with the site’s zoning designation and will be subject to conformance with all applicable building, fire, and safety codes. 2. That, consistent with the City’s Community Design Guidelines, the Project is compatible in scale, siting, detailing, and overall character with buildings in the neighborhood. 3. That consistent with the City’s Community Design Guidelines, the Project incorporates articulation, massing, and a mix of color/finish materials that are compatible with the neighborhood. SECTION 2. Environmental Review. The Planning Commission adopted a Negative Declaration (ER 25-13) of Environmental Impact on August 14, 2013 finding the Project to not have the potential for significant effects on the environment. Attachment 1 ARC1 - 6 Resolution No. ARC-####-15 Page 2 323 Grand Avenue, ARC 25-13 SECTION 3. Action. The Architectural Review Commission hereby grants final approval to the project with incorporation of the following conditions: Planning Department 1. Density for this project is limited to four 4-bedroom residences. A “Conditions of Use of Structure” agreement that stipulates that each dwelling shall have no more than four bedrooms, as defined in the Zoning Regulations, will need to be signed in the presence of a notary and submitted prior to construction permit issuance. 2. Final project design and construction drawings shall be in substantial compliance with the project plans approved by the ARC. A separate full-size sheet shall be included in working drawings submitted for a building permit that list all conditions, and code requirements of project approval as Sheet No. 2. Reference should be made in the margin of listed items as to where in plans requirements are addressed. Any change to approved design, colors, materials, landscaping or other conditions of approval must be approved by the Director or Architectural Review Commission, as deemed appropriate. 3. Plans submitted for a building permit shall call out the colors and materials of all proposed building surfaces and other improvements on elevation drawings. Plans shall clearly note that all stucco surfaces are not a sprayed-on product and have a smooth hand-troweled or sand finish appearance to the satisfaction of the Community Development Director. 4. Plans submitted for a building permit shall include window details indicating the type of materials for the window frames and mullions, their dimensions, and colors. Plans shall include the materials and dimensions of all lintels, sills, surrounds recesses and other related window features. 5. The locations of all lighting, including bollard style landscaping or path lighting, shall be included in plans submitted for a building permit. All wall-mounted lighting fixtures shall be clearly called out on building elevations included as part of working drawings. All wall- mounted lighting shall complement building architecture. The lighting schedule for the building shall include a graphic representation of the proposed lighting fixtures and cut- sheets on the submitted building plans. The selected fixture(s) shall be shielded to insure that light is directed downward consistent with the requirements of the City’s Night Sky Preservation standards contained in Chapter 17.23 of the Zoning Regulations. 6. Mechanical and electrical equipment shall be located internally to the building. With submittal of working drawings, the applicant shall include sectional views of the building, which clearly show the sizes of any proposed condensers and other mechanical equipment. If any condensers or other mechanical equipment is to be placed on the roof, plans submitted for a building permit shall confirm that parapets and other roof features will adequately screen them. A line-of-sight diagram shall be included to confirm that proposed screening will be adequate. This condition applies to initial construction and later improvements. 7. A final landscaping plan, including irrigation details and plans, shall be submitted to the Attachment 1 ARC1 - 7 Resolution No. ARC-####-15 Page 3 323 Grand Avenue, ARC 25-13 Community Development Department along with working drawings. The legend for the landscaping plan shall include the sizes and species of all groundcovers, shrubs, and trees with corresponding symbols for each plant material showing their specific locations on plans. a. Any proposed landscape lighting shall be shown on plans submitted for a building permit and plans shall clearly indicate lighting to utilize a narrow cone of light (no brighter than approximately 15 watts) for the purpose of confining the light to the object of interest. b. Subject to the final approval of the Community Development Director, front yard areas shall include a landscape layout similar to that found along this portion of Grand Avenue which generally includes more open front yards which are not designed as primary outdoor space. The proposed 30 inch hedge shall be replaced with alternate landscaping. c. Front yard landscaping and landscaping along the common access way shall be of a sufficient height/density to screen parking spaces beyond (approximately 3 feet minimum height). 8. Plans submitted for a building permit shall include a final fencing plan indicating the fencing style, locations, and heights. 9. Final monument sign design and location shall be shown on plans submitted for a construction permit and shall be to the final approval of the Community Development Director. If the sign is proposed to be illuminated, detailed plans for sign illumination shall be included with the sign design and lighting shall be designed for consistency with the City’s Night Sky Ordinance and designed for durability. 10. The location of any required backflow preventer and double-check assembly shall be shown on all site plans submitted for a building permit, including the landscaping plan. Construction plans shall also include a scaled diagram of the equipment proposed. Where possible, as determined by the Utilities Director, equipment shall be located inside the building within 20 feet of the front property line. Where this is not possible, as determined by the Utilities Director, the back flow preventer and double-check assembly shall be located in the street yard and screened using a combination of paint color, landscaping and, if deemed appropriate by the Community Development Director, a low wall. The size and configuration of such equipment shall be subject to review and approval by the Utilities and Community Development Directors. 11. The applicant shall defend, indemnify, and hold harmless the City and/or its agents, officers, and employees from any claim, action, or proceeding against the City and/or its agents, officers, or employees to attack, set aside, void, or annul the approval by the City of this project, and all actions relating thereto, including but not limited to environmental review (“Indemnified Claims”). The City shall promptly notify the applicant of any Indemnified Claim upon being presented with the Indemnified Claim, and City shall fully cooperate in the defense against an Indemnified Claim. Attachment 1 ARC1 - 8 Resolution No. ARC-####-15 Page 4 323 Grand Avenue, ARC 25-13 Engineering Division 12. The building plan submittal shall show compliance with all subdivision conditions of approval for the project. 13. Projects involving the construction of new structures requires that complete frontage improvements be installed or that existing improvements be upgraded per city standard. MC 12.16.050 14. Any section of damaged or displaced curb, gutter, sidewalk, or driveway approach shall be repaired or replaced to the satisfaction of the Public Works Director. 15. The existing driveway approach that is to remain shall be verified as complying with ADA and City standards for accessibility. If not accessible, the approach shall be altered or upgraded to comply with current standards. The current City and ADA standard requires a 4’ sidewalk extension behind the ramp. 16. The building plan submittal shall show all required changes to the site plan for parking circulation to the satisfaction of the Community Development Director. a. The proposed parallel parking space in front of Lot 1 shall be removed in favor of landscaping. The driveway/curb design for the common access way between Lots 1 and 4 shall widen from 20-feet to a minimum of 24-feet, symmetrically. b. An additional parking space shall be provided in between Lots 3 and 4 (to account for the removal of the parallel parking space referenced in 1a above). The two parking spaces shall be lengthened to 24-feet from the property line along the common access way. This dimension can assume 30-inches for vehicle overhang. c. The two parking spaces in between Lots 1 and 2 shall be lengthened to 22-feet from the property line along the common access way. This dimension can assume 30-inches for vehicle overhang. 17. Development shall comply with Parking and Driveway Standards for dimension, maneuverability, slopes, drainage, and materials. Alternative paving materials are recommended for water quality and/or quality control purposes and in the area of existing or proposed trees and where the driveway or parking area may occur within the dripline of any tree. Alternative paving materials shall be approved to the satisfaction of the Planning Division. 18. The City Arborist shall approve all proposed tree removals prior to building permit issuance, demolition permits, and/or grading permit approvals. The trees may be removed if they are in decline, are creating damage to infrastructure, can’t be reasonably protected during demolitions, or are in areas of new construction and new tree plantings. The site development plan and parking layout shall consider potential tree preservations in the final design. Attachment 1 ARC1 - 9 Resolution No. ARC-####-15 Page 5 323 Grand Avenue, ARC 25-13 19. Trees located within the building footprints are approved for removal in conjunction with an approved building permit. The other existing sideyard trees shall be retained unless otherwise approved for removal by the City Arborist and Community Development Director. A tree removal proposal may require a report from a certified arborist with a summary of why the trees can’t be saved. If approved for removal, compensatory tree planting(s) may be required to the satisfaction of the City Arborist. 20. The building plan submittal shall show all existing and proposed trees. Off-site trees with canopy or root systems located in the area of the new construction shall be shown for reference. The plan shall show all trees to remain and shall include appropriate tree preservation notes. 21. The final landscape plan shall agree with the architectural site plan and engineered grading and drainage plan. Plantings proposed for detention basin areas shall be evaluated and approved by the landscape designer and the City of San Luis Obispo. 22. One 15-gallon street tree shall be required for each 35 linear feet of frontage. The City Arborist shall approve the tree species, planting requirements, and whether the street trees shall be planted in tree wells in the sidewalk area or behind the back of walk in the front yard. 23. Tree protection measures shall be implemented to the satisfaction of the City Arborist. The City arborist shall review and approve the proposed tree protection measures prior to commencing with any demolition, grading, or construction. Any safety pruning or cutting of substantial roots shall be approved by the city and completed by a city-approved arborist. Fire Department 24. Building construction type will require Type II-B with one-hour fire rated separation between dwelling units. Project will require an NFPA 13 fire sprinkler system. These requirements are a trade-off for lack of Fire Department ladder truck access to the new building. 25. Fire sprinkler system OS&Y/backflow device shall be located within 40 feet of existing hydrant. 26. OS&Y/backflow device can be located vertically inside the building, facing the street, if it is in a two-hour fire rated room/closet with exterior door access. Backflow device shall be within 20 feet of the property line at the street. Utilities Department 27. Sheet C-1 does not currently show the sewer laterals that serve either Lot 1 or Lot 4. Sheet C- 1 does not show how water service will be extended from the meter to either Lot 2 or Lot 3. Plans submitted for a building permit shall include a plan that delineates the location of the Attachment 1 ARC1 - 10 Resolution No. ARC-####-15 Page 6 323 Grand Avenue, ARC 25-13 property’s existing and proposed water meter(s), water services, and sewer laterals to the points of connection at the City water and sewer mains. 28. The property’s existing sewer laterals to the point of connection at the City main must pass a video inspection, including repair or replacement, as part of the project. The CCTV inspection shall be submitted during the Building Permit Review Process for review and approval by the Utilities Department prior to issuance of a Building Permit. 29. Private utility easements shall be provided for water and sewer infrastructure that is proposed to cross property lines (including water service and sewer lateral that crosses Lot 1 to serve Lot 2 and that crosses Lot 4 to serve lot 3). Note: Code requirements provided to applicant separately. On motion by Commissioner ___________, seconded by Commissioner _____________, and on the following roll call vote: AYES: NOES: REFRAIN: ABSENT: The foregoing resolution was passed and adopted this 6th day of April, 2015. _____________________________ Phil Dunsmore, Liaison Architectural Review Commission Attachment 1 ARC1 - 11 Attachment 2 ARC1 - 12 Attachment 2 ARC1 - 13 Attachment 2 ARC1 - 14 Attachment 2 ARC1 - 15 Attachment 2 ARC1 - 16 Attachment 2 ARC1 - 17 Attachment 2 ARC1 - 18 Attachment 2 ARC1 - 19 Attachment 2 ARC1 - 20 Attachment 2 ARC1 - 21 Attachment 2 ARC1 - 22 Attachment 2 ARC1 - 23 Attachment 2 ARC1 - 24 Attachment 2 ARC1 - 25 Attachment 2 ARC1 - 26 Attachment 2 ARC1 - 27 Attachment 2 ARC1 - 28 Attachment 2 ARC1 - 29 Attachment 2 ARC1 - 30 Attachment 2 ARC1 - 31 Attachment 2 ARC1 - 32 Attachment 2 ARC1 - 33 ෘ Attachment 2 ARC1 - 34 Attachment 3 ARC1 - 35 Attachment 3 ARC1 - 36 Attachment 3 ARC1 - 37 Attachment 3 ARC1 - 38 Attachment 3 ARC1 - 39 Attachment 3 ARC1 - 40 Attachment 3 ARC1 - 41 Attachment 3 ARC1 - 42 ARCHITECTURAL REVIEW COMMISSION AGENDA REPORT SUBJECT: Review of plans for four new single-family residences and associated site improvements. PROJECT ADDRESS: 323/353 Grand Avenue BY: Marcus Carloni, Associate Planner Phone Number: (805) 781-7176 e-mail: mcarloni@slocity.org FILE NUMBER: ARC 25-13 FROM: Phil Dunsmore, Senior Planner RECOMMENDATION Continue the project with direction to the applicant on revisions, based on findings, and subject to conditions. SITE DATA Applicant Ryan Petetit, John Belsher, PB Companies Representative Steve Rigor, Arris Studio Architects Zoning R-1 (Low-Density Residential) General Plan Low Density Site Area 0.53 Acres (23,132 square feet) Environmental Status Negative Declaration adopted by Planning Commission (ER 25-13) on August 14, 2013. SUMMARY The project includes development of four single-family residences on a project site recently (August 14, 2013) approved by the Planning Commission for a four-lot subdivision with exceptions to lot area and dimensions (approved with area and dimensions similar to those allowed in the R-2 zone; close to 5,000 square feet). Staff finds the overall design and detailing of the proposed residences to incorporate architectural characteristics that are found in the existing neighborhood and are consistent with the Community Design Guidelines. However, staff has noted conflicts with the Community Design Guidelines with regard to the size/scale of the four proposed in-fill residences as they relate to the existing neighborhood fronting Grand Avenue and has recommended modifications to the project for consistency with the Community Design Guidelines (section 4.2 below). Additionally, staff has noted insufficient site circulation and recommends modifications to the site plan for consistency with the Parking and Driveway Standards (section 4.1 below). Meeting Date: January 21, 2014 Item Number: 1 Attachment 4 ARC1 - 43 ARC 25-13 (323/353 Grand Avenue) Page 2 2.0 COMMISSION’S PURVIEW The ARC’s role is to review the project in terms of its consistency with the Community Design Guidelines and applicable City standards. 3.0 PROJECT INFORMATION 3.1 Site Information/Setting The project site encompasses two parcels; 323 Grand Avenue (12,032.63 square feet) and 353 Grand Avenue (11,099.33 square feet). The project site is located on the west side of Grand Avenue between McCollum and Fredericks Streets. The two parcels are in the Low-Density Residential (R-1) zone and are encompassed by R-1 zoning with single-family residences (Attachment 1, Vicinity Map). The project site is gently sloping (approximately 4% average cross slope) and is developed with two single-family residences (to be demolished); one per parcel. Each parcel has a driveway providing access from Grand Avenue and minimal other improvements. Attachment 2, Project Plans, Sheet A0.2 illustrates the sites existing conditions (structures, trees, hardscape). Site Size ~23,000 square feet Present Use & Development Two R-1 parcels with one single-family residence each Topography Flat: ~4 percent cross slope Access Grand Avenue Surrounding Use/Zoning North: Single-Family Residence (R-1 zone) South: Single-Family Residence (R-1 zone) East: Grand Avenue + Single Family Residences (R-1 zone) West: Single Family Residences (R-1-Planned Development zone) 3.2 Project Description The proposed project includes the following significant features (Attachment 2, Project Plans): 1. 4-parcel flag lot subdivision (recently approved, see section 3.3 below) 2. Construction of four detached single-family residences (two story homes): a. Lot 1: 2,258 square foot1 4-bedroom, 3-bath residence b. Lot 2: 2,866 square foot1 4-bedroom, 4-bath residence c. Lot 3: 2,650 square foot1 4-bedroom, 4-bath residence d. Lot 4: 2,425 square foot1 4-bedroom, 3-bath residence 3. Common access driveway (porous pavers) providing access to lots 2, 3, and 4 with guest parking spaces. 4. Tree removals. No removal of heritage trees (Attachment 5, Existing Site Plan, indicates tree types and sizes). The City Arborist supports tree removals that are within the 1 The square footage calculation does not include garages (502 square foot average size) or porch/decks (294 square foot average size). Attachment 4 ARC1 - 44 ARC 25-13 (323/353 Grand Avenue) Page 3 footprint of the proposed residences. Trees outside of the footprints and access way need to be maintained to the maximum extent feasible or approved for removal by the Tree Committee. 5. Craftsman architectural style: a. Horizontal siding (4 or 6-inch siding) with decorative wainscoting (8-inch siding) and board and batten gable accenting with wood outlookers. b. Covered porches with tapered columns and brick bases. 3.3 Project Statistics Item Proposed 1 Ordinance Standard 2 Street Yard Setback 20 feet 20 feet Other Yard Setback (sides and rear) Compliant Varied Max. Height of Structure(s) 25 feet 25 feet Building Coverage (footprints) 35.9% to 39.2% 40% Parking Spaces Lot 1 2 (plus guest spaces) 2 Parking Spaces Lots 2, 3, 4 3 3 (due to access from flag lot) Notes: 1. Applicant’s project plans 2. City Zoning Regulations 3.3 Background On August 14, 2013 the Planning Commission (PC) approved a subdivision of the project site allowing four parcels to be created from two existing parcels (the map has not yet been recorded). The subdivision included exceptions from the Subdivision Regulations due to substandard lot depths (mean lot depth reduction of 18 feet) and substandard lot areas (mean lot area reduction of 762 square feet per lot). The Planning Commission expressed concern with the intensity of development that would be allowed with the creation of four parcels where three parcels would otherwise be allowed and discussed the possibility of applying R-2 density standards to these lots, which would result in a maximum of four 3-bedroom homes. The project was represented to the Planning Commission with smaller structure footprints and additional parking spaces (compare Attachment 3, Parking Layout Reviewed by Planning Commission to Attachment 2, Project Plans, Sheet A-0.1). Ultimately, the Planning Commission decided not to condition specific home sizes or number of bedrooms per home since the project still needed review by the ARC. The Planning Commission did add a condition that no Secondary Dwellings Units be utilized in the project (since Secondary Dwelling Units are not allowed on substandard parcels). Table 1.0 Approved vs. Required Lot Dimensions Table Min. Lot Area (sq. ft.) Min. Width (feet) Min. Depth (feet) Min. Street Frontage (feet) Requirement (R-1 zone) 6,000 50 90 20 Proposed Lot 1 5,166 69 74 69 Proposed Lot 2 5,553 75 69 20 Proposed Lot 3 5,202 (7,382 gross) 73 79 20 Proposed Lot 4 5,031 78 65 20 *Bold font indicates compliant with standards Attachment 4 ARC1 - 45 ARC 25-13 (323/353 Grand Avenue) Page 4 Additionally, the Planning Commission recommended the ARC consider one driveway accessing all parcels on the project site which would result in elimination of backing out onto Grand Avenue (from lot 1). The project plans (Attachment 2) include one common access driveway serving three of the residences and a separate driveway serving lot 1 (as was shown on plans reviewed by the PC). 4.0 PROJECT ANALYSIS 4.1 Site Plan: The applicant’s preliminary grading plan (reviewed by the Planning Commission) included approximate building footprints and a parking layout (Attachment 3, Parking Layout). With further development of the home designs/site plan, some of these parking spaces have been eliminated including a parking space now shown as a loading area and driveway of insufficient length to accommodate a parked car (16’-8’ driveway length shown on lot 2). The current parking layout constrains on-site vehicle circulation (vehicles exiting from the guest spaces between lots 2 and 3, in particular) to the point where parking is awkward and potentially unsafe (it is possible that residents will back out onto Grand Avenue instead of using the loading zones to turn around). The applicant provided a vehicle circulation plan (Attachment 2, Project Plans, Sheet A0.3), however, the plan does not indicate adequate vehicle circulation from all guest parking spaces (the easternmost guest space on lot 1, the driveway spaces on lot 2, the guest space on lot 3, and the guest space on lot 4). For sufficient on-site vehicle circulation, staff recommends the ARC provide the following direction to the applicant: 1. Provide a vehicle circulation plan that provides adequate and safe vehicle circulation for compliance with the Parking and Driveway Standards. a. Increase the common access way width to allow adequate backup space for vehicles using all parking spaces (24-feet minimum). b. Increase the driveway depth for lot 2 in order to allow vehicles to park in the driveway without overlapping the common access way (18-feet, 5-inches minimum). c. Provide adequate circulation for the guest space on lot 3 (allowing a vehicle to exit the site in a forward motion with no more than two maneuvers). d. Reduce the depth of the guest spaces on lots 2 and 3 to discourage tandem parking that will overlap into the common access way. 4.1.1 Lot 1 Driveway: As discussed in section 1.0 above, the Planning Commission recommended the ARC consider one driveway accessing all parcels on the project site. The project plans (Attachment 2) still include two driveways (one common access drive and a second driveway accessing lot 1). The Engineering Division can support the dual driveway design as compliant with Parking and Driveway standards. 4.2 Building Designs: Staff supports the overall design and detailing of the four residences. The use of materials and detailing is consistent throughout all elevations providing four-sided architecture and incorporating architectural characteristics (muted-tone color scheme, covered entries, horizontal siding, composite roofing, brick accents) for compatibility with existing Attachment 4 ARC1 - 46 ARC 25-13 (323/353 Grand Avenue) Page 5 houses in the neighborhood2. However, the scale and massing of the project conflict with the recommendations of the Community Design Guidelines. The project is classified as “infill development” in the Community Design Guidelines (Chapter 5.3), one of the goals of which is “to provide for infill projects of high architectural quality that are compatible with existing development…and continue existing neighborhood patterns.” Staff has compiled data on properties within 300 feet of the subject location (Attachment 4, Neighborhood Study & Map) in order to understand the proposed projects compatibility with the existing neighborhood. The data is based on a comparison of living space (square footage) to lot size which is expressed as a percentage. Attachment 4 (Neighborhood Study & Map) concludes with the following information shown in the below table: Table 4.2 Neighborhood Study Conclusion Average living space to lot size ratio Average Home Size Average Lot Size All residences within 300-feet 24% 1,774 sq.ft. 7,827 sq.ft. Leroy Court Planned Unit Development only 42% 2,333 sq.ft. 5,697 sq.ft. All residences excluding Leroy Court PUD 21% 1,680 sq.ft. 8,229 sq.ft. Proposed Project 49% 2,550 sq.ft. 5,238 sq.ft. Lot 1 44% 2,258 sq.ft. 5,166 sq.ft. Lot 2 52% 2,866 sq.ft. 5,553 sq.ft. Lot 3 51% 2,650 sq.ft. 5,202 sq.ft. Lot 4 48% 2,425 sq.ft. 5,031 sq.ft. The proposed project’s average home sizes are considerably larger than the average size of residences within 300 feet of the project site, which is significant given the fact that the project site’s recently approved four parcels are sub-standard3 and are also below the average lot size for the neighborhood (i.e. larger homes on smaller lots). For comparison, if these homes were located on lots in a higher density zone such as R-2 (Medium-Density Residential), a maximum of four 3-bedroom residences could be constructed because density standards in higher density zones are calculated based on lot sizes. In this instance, the design of larger homes on smaller lots results in taller, “blockier,” buildings because the structures footprint needs to be smaller (in order to meet the 40% coverage4 limitation) which results in more of a two-story stacked structure as opposed to some of the further articulated neighboring structures which have larger base footprints due to their conforming lot sizes. Although the home sizes and designed articulation are somewhat similar to those of the Leroy Court Planned Unit Development (directly west of the project site), the proposal to construct larger homes on smaller lots presents a compatibility concern with the existing residences fronting Grand Avenue, a significant corridor. The Community Design Guidelines state “when 2 Community Design Guidelines Chapter 5.3.B: Building Design. An infill residential structure should incorporate the traditional architectural characteristics of existing houses in the neighborhood, including window and door spacing, exterior materials, roof style and pitch, ornamentation and other details. 3 Minimum lot size in the R-1 zone is 6,000 square feet 4 Zoning Regulations Chapter 17.00 Coverage: Coverage. The area of a structure on or above the ground including upper level projections and living areas, as well as covered or uncovered decks, balconies, porches and similar architectural features expressed as a percentage of the total lot area. Uncovered decks, balconies, and porches which are 30 inches or less from the ground shall not be included in the determination of coverage …” Attachment 4 ARC1 - 47 ARC 25-13 (323/353 Grand Avenue) Page 6 new homes are developed adjacent to older ones, the height and bulk of the new construction can have a negative impact on adjacent, smaller scale buildings”…therefore, “infill residential development should be compatible in scale, siting, detailing, and overall character with adjacent buildings and those in the immediate neighborhood.” For consistency with the Community Design Guidelines, staff has added directional items for the ARC to consider reducing the overall square footage and massing of the proposed residences. Staff recommends the ARC provide the following direction to the applicant: 1. Lots 1 and 4: Reduce the overall square footage of the proposed residences (to approximately 2,000 square feet) for compatibility with the scale of existing adjacent residences fronting Grand Avenue and for lowered development intensity on these sub- 6,000 square foot parcels. 2. Lots 2 and 3: Reduce the overall square footage of the proposed residences (to approximately 2,400 square feet) for compatibility with the scale of the existing adjacent Leroy Court Planned Unit Development and for lowered development intensity on these sub-6,000 square foot parcels. 3. The reduction in square footage/scale of the proposed residences should include the elimination of accessory rooms (e.g. the “media rooms” shown on lots 1, 3, and 4 and the “den” shown on lot 2) while maintaining similar building footprints and providing reduced size upper floor areas. 5.0 OTHER DEPARTMENT COMMENTS The requirements of the other City departments are reflected in the directional items provided below. 6.0 ALTERNATIVES & RECOMMENDATION 6.1. Approve the project based on findings of consistency with the Community Design Guidelines. 6.2. Deny the project based on findings of inconsistency with the Community Design Guidelines. 6.3 Continue the project to a date uncertain with the following directional items: Planning Division 1. Provide a vehicle circulation plan that provides adequate and safe vehicle circulation for compliance with the Parking and Driveway Standards. a. Increase the common access way width to allow adequate backup space for vehicles using all parking spaces (24-feet minimum). b. Increase the driveway depth for lot 2 in order to allow vehicles to park in the driveway without overlapping the common access way (18-feet, 5-inches minimum). c. Provide adequate circulation for the guest space on lot 3 (allowing a vehicle to exit the site in a forward motion with no more than two maneuvers). d. Reduce the depth of the guest spaces on lots 2 and 3 to discourage tandem parking that will overlap into the common access way. Attachment 4 ARC1 - 48 ARC 25-13 (323/353 Grand Avenue) Page 7 2. Lots 1 and 4: Reduce the overall square footage of the proposed residences (to approximately 2,000 square feet) for compatibility with the scale of existing adjacent residences fronting Grand Avenue and for lowered development intensity on these sub- 6,000 square foot parcels. 3. Lots 2 and 3: Reduce the overall square footage of the proposed residences (to approximately 2,400 square feet) for compatibility with the scale of the existing adjacent Leroy Court Planned Unit Development and for lowered development intensity on these sub-6,000 square foot parcels. 4. The reduction in square footage/scale of the proposed residences should include the elimination of accessory rooms (e.g. the “media rooms” shown on lots 1, 3, and 4 and the “den” shown on lot 2) while maintaining similar building footprints and providing reduced size upper floor areas. Fire Department 5. Provide a monument sign positioned to be clearly visible from Grand avenue and showing the address of each building. 7.0 ATTACHMENTS a. Vicinity Map b. Project Plans c. Parking Layout Reviewed by Planning Commission (August 14, 2013) d. Neighborhood Study and Map e. Existing Site Plan Included in Commission member portfolio: project plans Available at ARC hearing: color/materials board Attachment 4 ARC1 - 49 PF R-1 R-1 R-1 R-1 R-1R-1 R-1 R-1 R-1 R-1 R-1-PD R-1 R-1 R-1 R-1 R-1 GR A N D GR A V E S McCOLLUM HAYS HOPE LOOMIS FREDERICKS VICINITY MAP File No. 25-13323 & 353 Grand ¯ ARC1 - 50 Attachment a Attachment b ARC1 - 51 Attachment b ARC1 - 52 Attachment b ARC1 - 53 Attachment b ARC1 - 54 Attachment b ARC1 - 55 Attachment b ARC1 - 56 Attachment b ARC1 - 57 Attachment b ARC1 - 58 Attachment b ARC1 - 59 Attachment b ARC1 - 60 Attachment b ARC1 - 61 Attachment b ARC1 - 62 Attachment b ARC1 - 63 Attachment b ARC1 - 64 Attachment b ARC1 - 65 Attachment b ARC1 - 66 Attachment b ARC1 - 67 Attachment b ARC1 - 68 Attachment b ARC1 - 69 Attachment b ARC1 - 70 Attachment b ARC1 - 71 Attachment b ARC1 - 72 Attachment b ARC1 - 73 ෘ Attachment b ARC1 - 74 Fl a g L o t S u b d i v i s i o n c r e a t i n g 4 l o t s f r o m t w o e x i s t i n g l a r g e l o t s 10 Pr o j e c t D e s c r i p t i o n Attachment c ARC1 - 75 32 3 / / 3 5 3 Gr a n d Av e n u e Pr e l i m i n a r y Pl a n sh o w n to Pl a n n i n g Co m m i s i o n Da r k Gr e y : Re q u i r e d Pa r k i n g Sp a c e s Li g h t Gr e y : Dr i v e w a y Pa r k i n g Sp a c e s Re d : Gu e s t Pa r k i n g Sp a c e s Source: City of SLO Neighborhood Study 39 38 52 40 30 2927 5453 49 48 475150 5 6 7 43 46 45 15 16 17 37 36 23 32 33 34 35 24 312526 28 1 2 3 4 18 21 2220 19 14118 9 12 1310 42 4441 Source: Esri, DigitalGlobe, GeoEye, i-cubed, Earthstar Geographics, CNES/Airbus DS, USDA, USGS,AEX, Getmapping, Aerogrid, IGN, IGP, swisstopo, and the GIS User Community 0 250 500125 Feet Public School Subject Site Comparison Parcels Gr a n d A v e n u e Figure 1 McCollum Street Hope Street Fredericks Street AR C 1 - 76 At t a c h m e n t d Attachment d Proposed Project Lot Size House Size % (house size/lot size) Lot 1 5166 2258 44% Lot 2 5553 2866 52% Lot 3 5202 2650 51% Lot 4 5031 2425 48% Map REF # Lot Size House Size % (house size/lot size) Address 1 6670 2826 42% 1724 McCollum Street 2 6560 2806 43% 1744 McCollum Street 3 6560 2826 43% 1764 McCollum Street 4 6850 2807 41% 1784 McCollum Street 5 10243 1971 19% 1661 McCollum Street 6 10160 2088 21% 1677 McCollum Street 7 14460 2992 21% 1693 McCollum Street 8 6500 2538 PUD 39% 301 Leroy Court 9 5070 2438 PUD 48% 317 Leroy Court 10 5060 2022 PUD 40% 321 Leroy Court 11 7810 2438 PUD 31% 302 Leroy Court 12 5040 2438 PUD 48% 316 Leroy Court 13 5010 2022 PUD 40% 328 Leroy Court 14 9950 2886 29% 311 Grand Avenue 15 10220 1276 12% 1660 Fredericks Street 16 10910 1568 14% 1676 Fredericks Street 17 14360 not found 1692 Fredericks Street 18 9670 2369 24% 1706 Fredericks Street 19 4200 0 PUD 347 Leroy Court 20 5390 2438 PUD 45% 1720 Fredericks Street 21 10490 800 8% 1740 Fredericks Street 22 6970 934 13% 1760 Fredericks Street 23 8420 2134 25% 395 Grand Avenue 24 8990 2256 25% 1661 Fredericks Street 25 8910 1084 12% 1739 Fredericks Street 26 11760 1424 12% 433 Grand Avenue 27 8510 1440 17% 436 Grand Avenue 28 15070 1484 10% 470 Grand Avenue 29 10490 1728 16% 1866 Loomis Street 30 7510 736 10% 476 Grand Avenue 31 5990 1110 19% 430 Grand Avenue 32 6020 1312 22% 410 Grand Avenue ARC1 - 77 Attachment d 33 6010 not found 1843 Hope Street 34 6010 1326 22% 1861 Hope Street 35 6010 1056 18% 1881 Hope Street 36 10110 1490 15% 1890 Hope Street 37 6130 not found 1840 Hope Street 38 13750 2318 17% 1820 Hope Street 39 5810 1712 29% 1810 Hope Street 40 6280 1520 24% 346 Grand Avenue 41 6030 2380 39% 320 Grand Avenue 42 6920 2380 34% 1825 McCollum Street 43 8310 1645 20% 1861 McCollum Street 44 5990 1726 29% 1865 McCollum Street 45 9280 1570 17% 357 Graves Avenue 46 8130 1089 13% 1889 McCollum Street 47 6760 880 13% 1874 McCollum Street 48 6760 1364 20% 1860 McCollum Street 49 6750 1224 18% 1844 McCollum Street 50 5020 880 18% 292 Grand Avenue 51 5000 884 18% 254 Grand Avenue 52 4990 1048 21% 250 Grand Avenue 53 6000 not found 236 Grand Avenue 54 6760 1224 18% 1841 Hays Street ARC1 - 78 Attachment 5 ARC1 - 37ARC1 - 79