HomeMy WebLinkAbout0095ORDINANCE NO. 95 (1958 Series)
AN ORDINANCE ADOPTING THE UNIFORM BUILDING CODER 1958 EDITION, VOLUME.I.
BE IT ORDAINED by the Council of the City of San Luis Obispo as follows:
SECTION 1. That Sections 8100.2, 8100.5, 810007, 8100.9, 8120, 8120.1 and
8120..2 of. the San Luis Obispo Municipal Code are hereby repealed.
SECTION 2. That Section 8100.3-is hereby amended to read as follows:
Section 810001 Uniform Buis Code Adopted.
That a certain document, three copies of which are on file in the
office of the City Clerk, being.marked and designated as "Uniform
Building Code, 1958 Edition, Volume Is" and which copies may be
identified by the Seal of the City of San Luis Obispo appearing
thereon, bee and the same is hereby adopted as the building code
of the City for.reguleting the erection, construction, enlargement,
alteration, repair, moving, removal, demolition, conversion,
occupancy, equipment, use, height, area and maintenance of all
buildings and structures in.the Citys providing for issuance of
building permits and collection of fees therefor; and each and
all of the regulations, provisions, penalties, conditions and terms
of the "Uniform Building�'Code, 1958 Editions Volume I" including
appendix contained therein'are hereby referred to, adopted and made
a part hereof as if fully set out in this Chapter; except such
provisions as are modified by the provisions of this Chapter.
SECTION 2. That Section 8100.2 shall read as follows:
Section 8100.2 Amendments.
The following sections of the Uniform Building Code, 1958 Edition,
Volume I, are hereby amended'to read as follows:
301 (b) Applications
To obtain a;.pQrin .t the applicant shall first file an application
therefor in writing` .on a form furnished for that purpose. Every such
application shall,:.°
1. Identify and describe the work to be covered by the permit
for which application,is made;
2. Describe the land on which the proposed work is to be done,
by lot, blocks tracts,and house and street address, or similar
description that; vill readi ly identify and definitely locate
the proposed buil�)in or, work;
3. Show the use or occupancy of all parts of the building;
4. Be accompanied by plans and specifications as required in
subsection (c) of this Section;
5. State the valuationi"of the proposed work;
b. Be signed by the permittee, or his authorized agent, who may
be required to submit,evidencb to'indicate such authority;
7. Give such other information.as.reasonably may be required by
the building official ;'
8. State whether structure is to be sold or is for applicant's
personal use;
9. If hiring help, if applicant is aware of the state compensation
and unemployment requirements;
10. State garage floor and street Oewations.
301 (c ) Plans and Specifications;
G'ith each application for; a building permit for any new construction
or any work involving structural change or addition to an existing structure,
�
,
or when required by the building official for enforcement of any provision
of this Code, three sets of plans and specifications shall be submittedo
The building official may require plans and specifications to be prepared
and designed by an en'g - cheer or architect licensed by the :state to practice
as such,
Exceptions: When authorized by the •buildin fr official, plans and
specifications need not be submitted for the following:
1. One -story buildings of Type V conventional wood -stud construction
with an area not exceeding 600 square feet;
2. Group J, Division 1, occupancies of Type V conventional wood -stud
construction;
3. Small and unimportant work.
302 (d) Expiration.
Every permit issued by the building official under the provisions of
this Code shall expire,by limitation and become null and void, if the
building or work authorized by such permit is not commenced within 60
days from the date of such,permit, or if the building or work authorized
by such permit is suspended or 'abandoned at any time After the work is
commenced for a period of-120-days. Provided further, that every permit
shall automatically expire 18 months after the date of issuance. before.
such work can be recommenced.a new permit shall be first obtained so to
do, and the fee therefor shall be one -half the amount required for a new
permit for such work, provided no changes have been made or will be made
in the original plans and specifications for such work; and provided,
further, that such.,suspension or abandonment has not exceeded one year.
Section' c) is'.hereby added to read:
303 (c) Schedule of, Investigation of Fees.
then work for which a:pe.rmit,is required under this Code is begun
or carried on without a p6kTdt, then no permit shall be issued in such
cases without a spacial investigation and.the payment of a special
investigation fee in addition to the double';fee set forth in Section
303 (a) to be determined by the following schedule.
For work which would have required
a permit fee of...'o e . . . . . . X10.00 or less,;... 1,10,00
over. a X10.00 to ;i•15.00... 41.15000
over . 415,00 to 420.00... 420.00
over. . iv20.00 or more..... 425.00
Payment of these fees shall not relieve any person from fully
complying with the requirements of'this Code nor from any penalty
prescribed by law.
1302 (b) Special Provisions,
Group H occupancies more than two stories in height or having more
than three thousand sGuats.feet ;(,x,000,sq.ft.) of floor area above the
first floor shall be of "n less than one -hour fire- resistive construction
throughout. Group H occupancies normally requirinf- fire - retardant roof
coverings may be permitted.to.have hand -split shakes, provided a solid
sheathing of gypsum Wallboard not less than one -half inch thick is first
applied over required wood sheathing or -other material of equivalent fire
retardant value.
For attic space and draft stops see Section 3205.
Section 1602 '(b) "shall be amended by adding the following paragraph at
the end of said sections
2.
6. Vo building already erected in Fire Zone I shall hereafter be
altered, raised, enlarged, added to, or moved in Fire Zone I unless
the altered or added portions be constructed and fire protected in
accordance -with•.requirements for new construction in Fire Zone I.
.`section 1603 (b) shall be amended by adding the following paragraph at
the end of said sectioni
No building already erected in Fire Zone Ii shall hereafter be
altered, raised, enlarged,:added to or.,moved in Fire Zone II
unless the altered or added portions be constructed and fire
protected in accordance-with requirements for new construction
in Fire Zone II.
Section 2606 shall be amended by adding ,the following paragraph at the
t•
end of said section:
111inimum concrete shall test at least 2,000 pounds per square inch,
Section 5102 (c-2) shall be amended by adding the fonowinr, paragraph
at the end of said section:
If such openings or ducts convey air from an attic space, the attic
space shall be ventilated by fresh air openings or louvres on a
vertical wall or at two different levels or elevations, and such
openings shall be provided on the upper side with a hinged wooden
cover one inch in thickness held in the open position by a fusible
link device approved by'the Chief of the City Fire Department,
5107 (b) 1-4ter Heaters Installed in Garda ess.
Gas water heaters installed in garages shall be adequately guarded
against mechanical injury and.from coming in contact with combustible
material and shall be•located at least 24 inches above floor level.
SECTION 3. This ordinance, together with the ayes and noes, shall be published
once in full, at least three days before its final passage, in the Telegram - Tribune,
a newspaper published and circulated in'said city, and the same shall go into effect
at the expiration of thirty days after its final passage.
INTPODUCED ARM PASSED TO PRINT this 1 thdathday of November , 1958,
by the following vote:
AYES: Nels Beck, Kenneth V. Jones, Richard G. Sleight, J. Barry Smith,
Fred H. Lucksinger
NOES: None
ABSENT, None
mayor
ATTEST:
3.
FINALLY PASSED this 1st of December . 1958; by the foltawing
Vote:
AYES: Nels Beck, Kenneth W. Jones, Richard G. Sleight, J. Barry Smith,
Fred H. Lucksinger
NOES: None
ABSENT: None
Mayor
ATTEST:
40
NOTICE OF PUBLIC HEARING
NOTICE IS HEREBY GIVEN that the City Council of the City of
San Luis Obispo will hold a public hearing on the recommendation of
the Building Board of Appeals for the City to adopt the 1964 Edition of
the Uniform Building Code and the 1964 Edition of the Uniform Plumbing
Code.
Said public hearing will be held on Monday, September 21, 1964
at 9:00 P.M. in the Council Chambers of the City Hall, 990 Palm Street,
San Luis Obispo, California.
J. H. FITZPATRICK
City Clerk
September 3 , 1 ")64
Chapter 2 - PLUMBING
SECTION 8200. Uniform Plumbing Code. Adopted.
The Uniform Plumbing Code, 1964 Edition, and appendices, three copies of which
are on file with the City Clerk and may be identified by the seal of the City
appearing thereon, is hereby adopted by reference as the Plumbing Code of the City,
except as amended by the provisions of this chapter.
SECTION 8200.1. Amendments.
The following sections of the Uniform Plumbing Code are amended as follows:
Section 1.1
Insert "Building Official" in the space provided.
Section 1.2
Insert "Building Inspector" in the space provided.
Section 1.3
Insert "Planning and Building" in the space provided.
Section 1.7
Insert.% "three- hundred dollars ($300) ", "City or County" and "three (3)" in the
appropriate spaces provided.
Section 1.10
Add Section 1.10(d) as follows:
A permit may be issued to an owner to replace a water heater in his dwelling or
apartment if such replacement does not require any changes or additions to the gas
or water piping systems.
Section 1.12. Add the following:
If work for which a permit is required under this Code is begun without a permit
the work shall stop upon notification by the Building Department. No permit shall
be issued in such cases without a special investigation and the payment of a special
fee, in addition to the double fee set forth in this section above, to be determined
by the following schedule:
J
v
\ ARTICLE VIII - BUILDING REGULATIONS
Chapter 1 - BUILDING CODE
UKAr i
August 31, 1964
SECTION 8100. Uniform Building Code. Adopted.
The 'Uniform Building Code, 1964 Edition, Volume I and appendices, 3i� copies
of,which are on file and may be identified by the seal of the City appearing
thereon with the City Clerk, is hereby adopted by reference as the Building
Code of the City, except as amended by the provisions of this Chapter.
SECTION 8100.1. Building Official.
The Director of Planning and Building is hereby designated the Building
.Official.
SECTION 8100.2. Civil Defense Shelters Exempt from Building Code.
1. Any structure which is designed exclusively as a Civil Defense shelter
is exempt from the Building Code.
SECTION 8100.3. Amendments
�The following sections of the Uniform Building Code, 1964 Edition, Volume
I are hereby amended as follows:
Section 301.
Add subsection 301(b)8 as follows: Show garage floor elevation and
street elevation opposite driveway.
Add the following to subsection 301(c): Three sets of plans shall be
submitted.
Section 302.
Add the following to subsection 302(d): Every permit shall. autorfirt -.
tically expire eighteen (18) months after date of issue.
Section 303.
Add the following to Section 303(a) : In addition to the < (oib.le fee
required by this section, a special investigation fee shall he paid
as follows:
Chapter 2 - PLUMBING -2- September 3, 1964
Normal fee Special Fee
$10.00 or less ------- --- ------- ------ $10.00
over $10.00 to $15.00 ----- ---------------- $15.00
over $15.00 to $20.00 ------ --- ---- -------- $20.00
$20.00 or more ------ ----------------- $25.00
Payment of these fees shall not relieve any person from fully complying with
the requirements of the Plumbing Code nor from any penalty set forth in Section 1.7.
No permit shall be issued unless all fees due are paid.
Section 2.5(b).
Delete.
Section 2.9(b)
Insert "June 30th" in the space provided.
f Section 2.10
Insert "one dollar ($1.00)" and "two dollars ($2.00)" in the appropriate spaces
provided.
Section 711
Add 711(o) as follows:
No pot sink or other fixture shall discharge into the same grease interceptor
serving a dishwashing machine.
Section 910
Change section 910 to: Each building shall be provided with sanitary facilities
as listed in appendix "C" of this Code. Approved toilet facilities for workmen
shall be provided and maintained in a sanitary condition on the job site, during
the construction of buildings.
Section 1103
Add 1103(c) as follows:
No Bituminous fiber pipe shall be used as a building sewer.
Normal Fee:
Special Investigation Fee:
$to or lass ---------------------------------
- - - - -- $10.00
$lo to $15 ----------------------------------
- - - - -- $15.1)0
$15 to $20 ----------------------------------
- - - - -- $20.00
over$20 ------------------------------------
- - - - -- $25.00
Section 1711(f).
Add section 1711(f) as follows:. Section 909 of the Uniform Plumbing
Code regulating shower stalls shall apply.
Section 2517.
Add the following to Section 2517(c): In concrete formwork, 3/4" diameter
round metal stakes only, shall be permitted within required footings.
Section 2806.
Add this footnote to Table 28 -0 Not less than one continuous steel re-
inforcing bar, of at least one -half inch Q ") in diameter shall be placed
in all footings, and another 3 to 6 inches from the top of all foundation
walls except those footings resting directly on solid rock. Such bars
shall be installed in an approved manner.
Section 3203(d)8.
Change the first paragraph of section 3203(d)8 as follows:
Shakes shall be applied to roofs with solid or spaced sheathing. Spaced
sheathing shall be not less than one inch by four inches nominal size
and shall be spaced not to exceed seven and one -half. inches (71 ") center
to center for eighteen inch (18 ") shakes; ten inches (10 ") center, to
center for twenty -four inch (24 "); and thirteen inches (13 ") center to
center for thirty -two inch (32 ") shakes.
Section 3305(n).
Section 3305(n) shall be chat ed as follows: Every required stairway,
including landing, shall have unimpaired headroom of not less than six
feet six inches (616 ") for its entire length. Headroom shall mean the
` '"'`vertical distance fi
a
continuous straight liq?
drawn above,
tangent
to the stair nosings
and
one foot past top and
bottom nosings
and a line
,71?(-)vc: ai,(i parallel to such line:.
Section 3305(o).
Where stairs are provided to the roof of a building or structure they
shall be so constructed as to deny public access to the roof.
Exception - The public need not be denied access to such roof provided
it complies with section 2305(e) and section 3302(a) and the area to
which the public is admitted is enclosed with an unclimbable wall not
less than four feet six inches (41611) high. Doors and gates to such en-
closure shall be self- closing and self - latching with the latching hard-
ware located not less than four feet six inches (4'611) above the floor.
Section 5101(b).
Add the definition of Central Heating Plant or Heating Plant - Comfort
heating equipment installed in a manner to supply heat by means of ducts
or pipes to areas other than the room in which the equipment is located.
Section 7001.
Add the following to Section 7001: The City Engineer shall enforce this
chapter. Where "Building Official" appears in this chapter "City
.Engineer" shall apply.
Section 7007.
Add subsection 7007(g) as follows: All grading in residential zones
or within one thousand feet (1000') of any residential occupancy, hotel,
motel, or hospital shall be done between the hours of 7 :OOA.M. and
7:00 P.M. except in an emergency. All graded surfaces and materials
shall be wetted, protected or contained in such manner as to prevent
dust or spill upon any adjoining property or street.
Section 7012.
Change section 7012(c) to the following: The maximum slope of any fill
shall not exceed two (2) horizontal to one (1) vertical.