HomeMy WebLinkAbout06-21-2016 Item 14 Council Reading File - 91268 2015 CMP Projectgeneral notes 1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR PERMITTEE TO CONTACT "UNDERGROUND SERVICE ALERT OF NORTHERN CALIFORNIA" BY PHONE AT 8 -1 -1 FORTY -EIGHT (48) HOURS PRIOR TO START OF CONSTRUCTION FOR LOCATION OF POWER, TELEPHONE, OIL AND NATURAL GAS UNDERGROUND FACILITIES. CONTRACTOR OR PERMITEE SHALL ALSO CONTACT THE APPROPRIATE AGENCY FOR THE LOCATION OF CABLE T.V., WATER, SEWER, DRAINAGE OR UNDERGROUND FACILITIES. 2. THE CONTRACTOR SHALL POSSESS A CLASS "A" LICENSE AT THE TIME THE CONTRACT IS AWARDED. ro."/ - rf 1 . Wrd, THE HORIZONTAL DATUM IS THE NORTH AMERICAN DATUM OF 1983 (NAD83), CALIFORNIA COORDINATE SYSTEM (CCS) ZONE 5, EPOCH 1991.35, BASED UPON TIES TO POINTS PUBLISHED IN THE CITY OF SAN LUIS OBISPO HORIZONTAL CONTROL NETWORK, JANUARY 2007 ADJUSTMENT. THE VERTICAL DATUM IS THE NORTH AMERICA VERTICAL DATUM OF 1988 (NAVD88), BASED UPON TIES TO POINTS PUBLISHED IN THE CITY OF SAN LUIS OBISPO BENCHMARK SYSTEM, JANUARY 2007 ADJUSTMENT. I I J LAGUNA LAD N 0 500 1000 2000 SCALE IN FEET index to plans sheet no. description 1 GENERAL NOTES, LOCATION MAP 2 PLAN: BOND - KENTUCKY T M °NTH I 3 PLAN: SANTA YNEZ - LOOMIS �q�gAq cF ��. MIRA SOL 4 PLAN: FOOTHILL - CARPENTER �I D �� �A ��� �� I PROJECT n —I v do WESTMONT I I D 0S WESTMONT 1 LOCATIONS Q 'ES FEL -MAR �2 �� PROJECT r t BY ��NO HIGHLAND ° DARTMO JTH THE 1/2 PERCENT IREVENUE WARREN TOLOSA HIGHLAND A o DONNA Q Q FELTON �1 C� / ° o Reinvestment - • RFOOMOATUHLDILO L z D CERRO ROMAULDO LAC° K L ALBERT _ — 101 Project HA ° \)5 FOOTHILL o MCCOLLUM DEL NORTE \ O� _ - RAMONA z RAMONA w DESERET � ON Q ROUGED FRED KS FREDERICKS HOPE L z DEL SUR =DE MA�R_� Q w RA�MONA MEINECKE ❑ z ANTq y➢ 1� D D STAFFORD �� i J I I I I —I \ � � I S D� WILSON A BOTT Cr� CD D w � CD ��� �GARFIELD PEACH 04 o� KENDRA KRISTY C, D S N JENIFER y ° D � J G� FFQ P� Q N z <Q HIGH = m 2 oQ o U ° RACHELCT. w ANDERCO 4 ❑ ❑ ❑ E� z SYL LOREN P Q P� m Of m BRANCH s Y i ROUNDHOUSE L TCH SP�� G SAN RLO Q ° 0 z Q � Fn ON J SBRIDGE w c CLA � o � m o C ° Q CORRIDA m o � WOODBRIDGE o9 o PAC ��o CAUDILL �BR,DGE Q - D o Q O ° J MITCHELL C/7 LAWRENCE �0 MOR I ON TONERIDGE m Q C FONTANA � Mq e0NlTq �� 1 I I I I I I I I I I I I I y D� ti GREGOR OREc EDAR Q Reference Documents: City Standard Specifications - January 2016 Edition City Engineering Standards - January 2016 Edition san luis Obispo county, California CMP REPLACEMENTS 2015 • Bond - Kentucky • Santa Ynez - Loomis • Foothill - Carpenter SPECIFICATION NO. APPROVED BY Barbara Lynch City Engineer R.C.E. C053418 91268 DATE JUNE 2016 FILE NO. /LOCATION SHEET 1 OF 4 • •. 317.42 FL 317.63 FL 318.06 FL (N) 6" CURB N� N 2303882.96 E 5768247.58 CENTER OF CURB RADIUS= 15' NOTE: TAKE CARE TO NOT DISTURB (E) LANDSCAPING OUTSIDE OF RIGHT -OF -WAY. 318.12 FL (E) LANDSCAPING 318.06 FS � r 318.61 TC 319.50 TC MATCH (E) 0 318.31 FS (319.50 FS) 3 4 �o u, 0000 goo 0 0 ,zzzzzzzzzz 9% 11.4% 12" WIDE BORDER WITH %a" GROOVES APPROX. 18.6 O.C., TYP. 0 9.7% FH di CURB 318.20 TC 317.70 FL 317.75 FL i 2.8' i 2.0' 3.25' i � W i.0 4.5' �1� 5.5' RAMP DETAIL SCALE: 1" = 5' 10' -5" 6" THICK AC PAVEMENT BACKFILL TRENCH WITH 1 -SACK SLURRY OR CLASS II AGGREGATE BASE AT 95% COMPACTION Know what's below. Call before you dig. 33' -3" 3' 3' 2%- 2% _ 10.5' CASE D I 16' Y - I C) I I I Z w Of W U) Y 6.0' di 317.31 TC 316.81 FL I 1 WM UP O �x �n \ 317.99 FS \ `1� f \ � L Ln sdmh • •. 317.42 FL 317.63 FL 318.06 FL (N) 6" CURB N� N 2303882.96 E 5768247.58 CENTER OF CURB RADIUS= 15' NOTE: TAKE CARE TO NOT DISTURB (E) LANDSCAPING OUTSIDE OF RIGHT -OF -WAY. 318.12 FL (E) LANDSCAPING 318.06 FS � r 318.61 TC 319.50 TC MATCH (E) 0 318.31 FS (319.50 FS) 3 4 �o u, 0000 goo 0 0 ,zzzzzzzzzz 9% 11.4% 12" WIDE BORDER WITH %a" GROOVES APPROX. 18.6 O.C., TYP. 0 9.7% FH di CURB 318.20 TC 317.70 FL 317.75 FL i 2.8' i 2.0' 3.25' i � W i.0 4.5' �1� 5.5' RAMP DETAIL SCALE: 1" = 5' 10' -5" 6" THICK AC PAVEMENT BACKFILL TRENCH WITH 1 -SACK SLURRY OR CLASS II AGGREGATE BASE AT 95% COMPACTION Know what's below. Call before you dig. 33' -3" 3' 3' 2%- 2% _ 10.5' CASE D \--6" THICK CLASS 2 co AGGREGATE BASE 95% COMPACTION SCARIFY AND COMPACT 6" OF SUBGRADE TO 95% COMPACTION REMOVE (E) 18" CMP STORM DRAIN PIPE SECTION A -A SCALE: 1" = 5' m ii 19.22 TC) MATCH (E) m (318.72 FS) m U O 0 (E) AC PAVEMENT CONSTRUCTION LEGEND REMOVE (E) CURB & GUTTER OR CURB, GUTTER & SIDEWALK AND REPLACE AS SHOWN ON THE PLANS PER ENGINEERING STANDARDS 4030 OR 4110 AS APPROPRIATE. REMOVE AND REPLACE (E) ASPHALT CONCRETE PAVEMENT AS SHOWN ON THE PLANS. CONSTRUCTION NOTES 1O REMOVE (E) AC PAVEMENT AND REPLACE WITH (N) PCC CROSS GUTTER PER ENGINEERING STANDARD 4310, GRADES MODIFIED AS SHOWN PER PLAN AND SECTION A -A THIS SHEET. CONTRACT PRICE INCLUDES REMOVING (E) PCC CURB & GUTTER AND CONSTRUCTING (N) PCC CURB & GUTTER PER ENGINEERING STANDARD 4030 AS SHOWN ON PLANS. 2O REMOVE (E) 18" CMP STORM DRAIN PIPE & BOX PER SECTION A -A THIS SHEET. REMOVE (E) STORM DRAIN MANHOLE PER ENGINEERING STANDARD 6050. 3O PROTECT IN PLACE (UTILITY POLES THIS SHEET). OREMOVE (E) AC & BASE TO ACCOMMODATE A 12" STRUCTURAL PAVING SECTION. PROVIDE 6" THICK AC PAVING OVER 6" THICK AGGREGATE BASE PER SECTION A -A AND PLAN. SAW -CUT ALONG (E) TRENCH LINES AS SHOWN FOR PAVING SOUTH OF CROSS GUTTER. 4A GRADE ADJUST UTILITY COVER PER ENGINEERING STANDARD 6040. ORELOCATE (E) STOP SIGN AS SHOWN PER ENGINEERING STANDARD 7210. INSTALL (E) SIGN ON (N) POST. OREPLACE (E) WATER METER BOX & LID WITH (N) BOX & LID PER ENGINEERING STANDARD 6210. OREMOVE (E) PCC SIDEWALK AND REPLACE WITH (N) PCC SIDEWALK PER ENGINEERING STANDARD 4110. INSTALL (N) CURB RAMP PER DETAIL THIS SHEET, ENGINEERING STANDARD 4440 AND CALTRANS STANDARD PLAN A88A, CASE D. O8 PAINT (N) CURB RETURN RED. O9 REMOVE (E) STOP BAR & LEGEND AND RELOCATE AS SHOWN. I I I 1 >n I N II I I SCALE: 1 " =10' w I I I I I 0 10 20 LL I I I I I 1 I � I``' I � � Li I < U I W 1 < < nl 1 01 00 L'i 1 UI I Q1 LLJI vl �� I 3: w I I I N 2303897. 2 E 5768233 5 I I 1 2.0 317.52 FS I N 2303890.14 I I I I I -MATCH (E) E 5768192.73 1 (317.02) FLI I H E 1 A 4A 1 MAT O AC CURB 315.73 FS 315.23 F 34.91 ao 1 8 L 1 314.60 IN WV I N 2303885.00 ld a, I 31694 FS NOTE: SEE RAMP DETAIL THIS SHEET E 5768176.61 L r\ I 1 i FOR MORE INFORMATION. CENTER OF CURB Ca I 6 3 RADIUS= 15' 4 I- - - I 7 2 N 2303870.13 (E) PCC BOX 314.41 FS / 8 I ° uP 3 / / ° 314.14 � � (E) SHRUBBERY----------_ E 5768171.97 - • / I 316.50 � FS �° MATCH (E) - -OHW- - - - -0 - MATCH (E) 312.11 FS 2 i�, 1 316.78- 2 W- HW ---- OHW--- (311_6)WFL I i cyH 77FS 0 W- W j -FS - a a HW-° - OHW - �• ° a -OHW- - - - -OHW- _ m ° - -- �1n(E�° 18 °CMP_ p 317 1° DMH ° �< 1 -OHW- - - - -OHW- f Fk�° °aI a _ _ 1 314.0 - - - - G - -(E) 3" GAS - - - 0 G - - - - G - - - G 313. 8 - G - - - - FIL I FL6.44 1 I 5 I 319.22 FS MATCH (E) cli IG 316.50 G - - G - - - (318.72) FL 313.44 314.11 I I - -� - - - - -G - - - - _ - - FS 2 FL (E) 4" WATER FS FS I FS 7.05 317.79 TG I (E N 3" 2303867.52 I I - - W - - - - - W - - - - 4A 4 314.25 INV I o - W - - - - - - - - - - - - - - - - - I WV ( ) E 5768263.83 4.2' - - - o E trench li e I 79.0'f 106.0' I I - _ _ < I I A ��W - - - - - W- - - -W - - - - W -- - WV -- (E) 8" WATER O I WV ° - -fin/- - - - -W- - - - -W- - - - - //- I 315.36 SMHI I 9 S _ - - - -S -(E) 6' -SEWER I I I w1 I o CO - \ 1 LL 1 I /•� C P 17 1 � � 317.41 \ I I I U 1 I 1 U 11 BOND STREET LA r O N N H Z W W V a J a w a v ui .I 16' -9" - \--6" THICK CLASS 2 co AGGREGATE BASE 95% COMPACTION SCARIFY AND COMPACT 6" OF SUBGRADE TO 95% COMPACTION REMOVE (E) 18" CMP STORM DRAIN PIPE SECTION A -A SCALE: 1" = 5' m ii 19.22 TC) MATCH (E) m (318.72 FS) m U O 0 (E) AC PAVEMENT CONSTRUCTION LEGEND REMOVE (E) CURB & GUTTER OR CURB, GUTTER & SIDEWALK AND REPLACE AS SHOWN ON THE PLANS PER ENGINEERING STANDARDS 4030 OR 4110 AS APPROPRIATE. REMOVE AND REPLACE (E) ASPHALT CONCRETE PAVEMENT AS SHOWN ON THE PLANS. CONSTRUCTION NOTES 1O REMOVE (E) AC PAVEMENT AND REPLACE WITH (N) PCC CROSS GUTTER PER ENGINEERING STANDARD 4310, GRADES MODIFIED AS SHOWN PER PLAN AND SECTION A -A THIS SHEET. CONTRACT PRICE INCLUDES REMOVING (E) PCC CURB & GUTTER AND CONSTRUCTING (N) PCC CURB & GUTTER PER ENGINEERING STANDARD 4030 AS SHOWN ON PLANS. 2O REMOVE (E) 18" CMP STORM DRAIN PIPE & BOX PER SECTION A -A THIS SHEET. REMOVE (E) STORM DRAIN MANHOLE PER ENGINEERING STANDARD 6050. 3O PROTECT IN PLACE (UTILITY POLES THIS SHEET). OREMOVE (E) AC & BASE TO ACCOMMODATE A 12" STRUCTURAL PAVING SECTION. PROVIDE 6" THICK AC PAVING OVER 6" THICK AGGREGATE BASE PER SECTION A -A AND PLAN. SAW -CUT ALONG (E) TRENCH LINES AS SHOWN FOR PAVING SOUTH OF CROSS GUTTER. 4A GRADE ADJUST UTILITY COVER PER ENGINEERING STANDARD 6040. ORELOCATE (E) STOP SIGN AS SHOWN PER ENGINEERING STANDARD 7210. INSTALL (E) SIGN ON (N) POST. OREPLACE (E) WATER METER BOX & LID WITH (N) BOX & LID PER ENGINEERING STANDARD 6210. OREMOVE (E) PCC SIDEWALK AND REPLACE WITH (N) PCC SIDEWALK PER ENGINEERING STANDARD 4110. INSTALL (N) CURB RAMP PER DETAIL THIS SHEET, ENGINEERING STANDARD 4440 AND CALTRANS STANDARD PLAN A88A, CASE D. O8 PAINT (N) CURB RETURN RED. O9 REMOVE (E) STOP BAR & LEGEND AND RELOCATE AS SHOWN. I I I 1 >n I N II I I SCALE: 1 " =10' w I I I I I 0 10 20 LL I I I I I 1 I � I``' I � � Li I < U I W 1 < < nl 1 01 00 L'i 1 UI I Q1 LLJI vl �� I 3: w I I I N 2303897. 2 E 5768233 5 I I 1 2.0 317.52 FS I N 2303890.14 I I I I I -MATCH (E) E 5768192.73 1 (317.02) FLI I H E 1 A 4A 1 MAT O AC CURB 315.73 FS 315.23 F 34.91 ao 1 8 L 1 314.60 IN WV I N 2303885.00 ld a, I 31694 FS NOTE: SEE RAMP DETAIL THIS SHEET E 5768176.61 L r\ I 1 i FOR MORE INFORMATION. CENTER OF CURB Ca I 6 3 RADIUS= 15' 4 I- - - I 7 2 N 2303870.13 (E) PCC BOX 314.41 FS / 8 I ° uP 3 / / ° 314.14 � � (E) SHRUBBERY----------_ E 5768171.97 - • / I 316.50 � FS �° MATCH (E) - -OHW- - - - -0 - MATCH (E) 312.11 FS 2 i�, 1 316.78- 2 W- HW ---- OHW--- (311_6)WFL I i cyH 77FS 0 W- W j -FS - a a HW-° - OHW - �• ° a -OHW- - - - -OHW- _ m ° - -- �1n(E�° 18 °CMP_ p 317 1° DMH ° �< 1 -OHW- - - - -OHW- f Fk�° °aI a _ _ 1 314.0 - - - - G - -(E) 3" GAS - - - 0 G - - - - G - - - G 313. 8 - G - - - - FIL I FL6.44 1 I 5 I 319.22 FS MATCH (E) cli IG 316.50 G - - G - - - (318.72) FL 313.44 314.11 I I - -� - - - - -G - - - - _ - - FS 2 FL (E) 4" WATER FS FS I FS 7.05 317.79 TG I (E N 3" 2303867.52 I I - - W - - - - - W - - - - 4A 4 314.25 INV I o - W - - - - - - - - - - - - - - - - - I WV ( ) E 5768263.83 4.2' - - - o E trench li e I 79.0'f 106.0' I I - _ _ < I I A ��W - - - - - W- - - -W - - - - W -- - WV -- (E) 8" WATER O I WV ° - -fin/- - - - -W- - - - -W- - - - - //- I 315.36 SMHI I 9 S _ - - - -S -(E) 6' -SEWER I I I w1 I o CO - \ 1 LL 1 I /•� C P 17 1 � � 317.41 \ I I I U 1 I 1 U 11 BOND STREET LA r O N N H Z W W V a J a w a v ui iii J LU o w Of U) D Z LLI i Z O 00 DESIGNED BY: JL DRAWN BY: PS / JL CHECKED BY: DA APPROVED BY: BL SCALE: AS NOTED DATE JUNE 2016 CITY SPECIFICATION NO. 91268 SHEET NO. 2of4 Know what's below. Cell before you dig. CONSTRUCTION LEGEND REMOVE (E) CURB & GUTTER OR CURB, GUTTER & SIDEWALK AND REPLACE AS SHOWN ON THE PLANS PER ENGINEERING STANDARDS 4030 OR 4110 AS APPROPRIATE. REMOVE AND REPLACE EXISTING ASPHALT CONCRETE PAVEMENT AS SHOWN ON THE PLANS. PROFILE ACROSS SANTA YNEZ W (N) CATCH BASIN #11) } (LOCATION i- Z Q w 326.10 \ RIM (N) CATCH BASIN --(E)GPA LADE rc (LOCATION #) Q Em 324.0 0 \ RI 0_ CRADE o 324 MATCH (E) "I 324 323 323 0 22 SLOPE 1.1 % SLOPE 1.0% ± � — iW mmim 320.11 t Iii M 319.83 ± 319.73 IL SEE ENG. I ILK, 24" HDPE S ORM DRAIN, 318 SEE ENG. STD JUL] 6030 FOR I 4 TRENCH DETAIL erm.2111im m PROFILE ACROSS SANTA YNEZ PROFILE ACROSS LOOMIS Ljj Z uj I a � N Lu Z � y�\ goy I I CO) o 32 32 I _ G CONSTRUCTION NOTES 0 PROTECT IN PLACE. 7A REMOVE (E) PCC SIDEWALK AND REPLACE WITH (N) PCC SIDEWALK PER ENGINEERING STANDARD 4110 10 REMOVE (E) STORM DRAIN STRUCTURE AND INSTALL (N) CATCH BASIN PER ENGINEERING STANDARD 3360, CURB FACE OPENING PER PLAN. CONNECT (E) STORM DRAIN PIPE TO (N) STRUCTURE AND CUT /REMOVE PORTION OF PIPE THAT INTERFERES WITH THE (N) STRUCTURE. GROUT BETWEEN PIPE AND STRUCTURE. PRIOR TO CONSTRUCTION, VERIFY LOCATION AND DEPTH OF NEARBY GAS LINE. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. CONTRACT PRICE INCLUDES REMOVING AND REPLACING CURB, GUTTER & SIDEWALK AS SHOWN ON PLANS. 11 REMOVE (E) AC PAVEMENT AND REPLACE PER ENGINEERING STANDARD 6025. 12 REMOVE (E) 24" CMP AND INSTALL (N) 24" HDPE PIPE, REALIGN PER PLAN AND CONNECT TO (N) CATCH BASIN AND (E) HEADWALL PER ENGINEERING STANDARD 3540 AS SHOWN. TRENCH SECTION SHALL BE PER ENGINEERING STANDARD 6025 AT PAVEMENT AND 6030 AT NON -PAVED AREA. 13 PROVIDE 24" HDPE FLARED END SECTION. 13 PLACE HYDROSEED AND JUTE NETTING OR APPROVED EQUAL FOR DISTURBED SOIL AT SLOPED EMBANKMENT. I I I 1 I I � I 0 � I I I C2 I I I I 0 _I NI I � I MATCH (E) \ c I (325.18) FS FJ (324.U) FL c� AT H (E) S / i / V / i / / / / / / / f / / / / f G I �O / oc- / / / / / / 14 REMOVE (E) METAL GUARD RAILING AS NECESSARY TO ACCESS JUNCTION BOX. RESTORE RAILING TO ORIGINAL CONDITION UPON COMPLETION OF CONSTRUCTION IN AREA. MAINTAIN TEMPORARY BARRICADES. 14 REMOVE (E) CITY CHAIN -LINK FENCE AS NECESSARY TO ACCESS JUNCTION BOX. RESTORE FENCE TO ORIGINAL CONDITION UPON COMPLETION OF CONSTRUCTION IN AREA. 15 CONTRACTOR SHALL LOCATE AND REMOVE (E) JUNCTION BOX PRIOR TO STORM DRAIN INSTALLATION. 16 INSTALL (N) STORM DRAIN MANHOLE PER ENGINEERING STANDARD 3520. INVERTS AND MANHOLE SIZE (APX. 10.5' DEEP) SHALL BE VERIFIED PRIOR TO MANUFACTURING AND INSTALLATION. (N) MANHOLE LID SHALL BE AT OR SLIGHTLY ABOVE GRADE. RECONNECT (E) 18" CMP TO (N) MANHOLE. 17 RESTORE DISTURBED STRIPING AND PAVEMENT MARKINGS. 24 REMOVE (E) TREE AND GRIND STUMP TO 2 FEET BELOW GRADE. PLACE NEW TREE PER ENGINEERING STANDARD 8250. 0 PRUNE (E) TREE PER CITY ARBORIST AS NECESSARY TO ACCESS CONSTRUCTION AREA. \�FJ so \ /O j/ EX. GUARDRAIL t/ �QO dF 5P r O N N H Z W W V Q J a w 0� a 2 v iu F- U W O d ui J H H H W w U) DESIGNED BY: JL DRAWN BY: PS /JL CHECKED BY: DA APPROVED BY: BL SCALE: H: 1" = 10' V:1 " =2' D, G O O J i N w z Q z vJ DATE: JUNE 2016 CITY SPECIFICATION NO. 91268 PLAN FILE NO. / LOCATION SHEET NO. 3of4 --(E)GPA LADE -im Em MATCH (E) "I MATCH iW mmim Iii M SEE ENG. I ILK, I erm.2111im m 11 RACTORTO___,r' on. PROFILE ACROSS LOOMIS Ljj Z uj I a � N Lu Z � y�\ goy I I CO) o 32 32 I _ G CONSTRUCTION NOTES 0 PROTECT IN PLACE. 7A REMOVE (E) PCC SIDEWALK AND REPLACE WITH (N) PCC SIDEWALK PER ENGINEERING STANDARD 4110 10 REMOVE (E) STORM DRAIN STRUCTURE AND INSTALL (N) CATCH BASIN PER ENGINEERING STANDARD 3360, CURB FACE OPENING PER PLAN. CONNECT (E) STORM DRAIN PIPE TO (N) STRUCTURE AND CUT /REMOVE PORTION OF PIPE THAT INTERFERES WITH THE (N) STRUCTURE. GROUT BETWEEN PIPE AND STRUCTURE. PRIOR TO CONSTRUCTION, VERIFY LOCATION AND DEPTH OF NEARBY GAS LINE. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. CONTRACT PRICE INCLUDES REMOVING AND REPLACING CURB, GUTTER & SIDEWALK AS SHOWN ON PLANS. 11 REMOVE (E) AC PAVEMENT AND REPLACE PER ENGINEERING STANDARD 6025. 12 REMOVE (E) 24" CMP AND INSTALL (N) 24" HDPE PIPE, REALIGN PER PLAN AND CONNECT TO (N) CATCH BASIN AND (E) HEADWALL PER ENGINEERING STANDARD 3540 AS SHOWN. TRENCH SECTION SHALL BE PER ENGINEERING STANDARD 6025 AT PAVEMENT AND 6030 AT NON -PAVED AREA. 13 PROVIDE 24" HDPE FLARED END SECTION. 13 PLACE HYDROSEED AND JUTE NETTING OR APPROVED EQUAL FOR DISTURBED SOIL AT SLOPED EMBANKMENT. I I I 1 I I � I 0 � I I I C2 I I I I 0 _I NI I � I MATCH (E) \ c I (325.18) FS FJ (324.U) FL c� AT H (E) S / i / V / i / / / / / / / f / / / / f G I �O / oc- / / / / / / 14 REMOVE (E) METAL GUARD RAILING AS NECESSARY TO ACCESS JUNCTION BOX. RESTORE RAILING TO ORIGINAL CONDITION UPON COMPLETION OF CONSTRUCTION IN AREA. MAINTAIN TEMPORARY BARRICADES. 14 REMOVE (E) CITY CHAIN -LINK FENCE AS NECESSARY TO ACCESS JUNCTION BOX. RESTORE FENCE TO ORIGINAL CONDITION UPON COMPLETION OF CONSTRUCTION IN AREA. 15 CONTRACTOR SHALL LOCATE AND REMOVE (E) JUNCTION BOX PRIOR TO STORM DRAIN INSTALLATION. 16 INSTALL (N) STORM DRAIN MANHOLE PER ENGINEERING STANDARD 3520. INVERTS AND MANHOLE SIZE (APX. 10.5' DEEP) SHALL BE VERIFIED PRIOR TO MANUFACTURING AND INSTALLATION. (N) MANHOLE LID SHALL BE AT OR SLIGHTLY ABOVE GRADE. RECONNECT (E) 18" CMP TO (N) MANHOLE. 17 RESTORE DISTURBED STRIPING AND PAVEMENT MARKINGS. 24 REMOVE (E) TREE AND GRIND STUMP TO 2 FEET BELOW GRADE. PLACE NEW TREE PER ENGINEERING STANDARD 8250. 0 PRUNE (E) TREE PER CITY ARBORIST AS NECESSARY TO ACCESS CONSTRUCTION AREA. \�FJ so \ /O j/ EX. GUARDRAIL t/ �QO dF 5P r O N N H Z W W V Q J a w 0� a 2 v iu F- U W O d ui J H H H W w U) DESIGNED BY: JL DRAWN BY: PS /JL CHECKED BY: DA APPROVED BY: BL SCALE: H: 1" = 10' V:1 " =2' D, G O O J i N w z Q z vJ DATE: JUNE 2016 CITY SPECIFICATION NO. 91268 PLAN FILE NO. / LOCATION SHEET NO. 3of4 NOTE: SEE SPECIAL PROVISIONS FOR MORE INFORMATION . i i I I I 1 4X4 W4.0/4.0 WELDED WIRE FABRIC TACK WELD TO CULVERT EVERY 8" TRANSVERSELY AND 30" LONGITUDINALLY 1 I I (E) 54" CMP 10:1 SLOPE MIN. MINOR CONCRETE (INVERT PAVING) 2" MIN. ABOVE CORRUGATION FILL VOID OF SCOURED INVERT WITH MINOR CONCRETE (INVERT PAVING) VARIES VARIES PAVED INVERT DETAIL SCALE: 1" = 2' CONSTRUCTION LEGEND REMOVE (E) CURB & GUTTER OR CURB, GUTTER & SIDEWALK AND REPLACE AS SHOWN ON THE PLANS PER ENGINEERING STANDARDS 4030 OR 4110 AS APPROPRIATE. REMOVE AND REPLACE EXISTING ASPHALT CONCRETE PAVEMENT AS SHOWN ON THE PLANS AND PER CITY OF SAN LUIS OBISPO STANDARD DETAIL 6020. PROFILE AT FOOTHILL - CARPENTER Know what's below. Call before you dig. MATCH (E) 279.05) TC 278.55) FL 278.75 RIM 275.45 INV N 2304497.95 E 5767291.88 Q W= 4.0' 'n 06 J J O O LL o v o I 11 I II I I 0 I l I I I — I d I I I II I I I I� I I I I I I I I 11 I — — I W- I, cra I 278.88 TC 2 278.p0 FL 1j (278.37 TC)' ` 277.87 FL) I I I MATCH (E) I I c/) IILiI I Lj I 17 �I QI i 0 tI — rH I� —OIHW- I� I ILu IN I I� I I I I I G - I I I S ,� �� e Q cj� � I I I I I I I I I cn I I W� - - - -W -- � I IU I wl I Li LiI I � I w1 I � I I I I I I I I U) I I I I 111 I I I — I I I I I I I I DO, I I —ea CONSTRUCTION NOTES OPROTECT IN PLACE. 11 REMOVE (E) AC PAVEMENT AND REPLACE PER ENGINEERING STANDARD 6025. 17 RESTORE DISTURBED STRIPING AND PAVEMENT MARKINGS. 18 RELOCATE (E) 1" COPPER WATER LATERAL PER ENGINEERING STANDARD 6210. VERIFY LOCATION WITH ENGINEER PRIOR TO INSTALLATION. REPLACE (E) WATER METER BOX AND LID WITH (N) BOX AND LID. S REMOVE (E) STORM DRAIN STRUCTURE AND INSTALL (N) CATCH BASIN PER ENGINEERING STANDARD 3355, CURB FACE OPENING PER PLAN. CONNECT (N) STORM DRAIN PIPE TO (N) STRUCTURE. PRIOR TO CONSTRUCTION, VERIFY LOCATION AND DEPTH OF NEARBY GAS LINE. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. CONTRACT PRICE INCLUDES REMOVING AND REPLACING CURB, GUTTER & SIDEWALK AS SHOWN ON PLANS AND (N) AC PAVEMENT (NOTE 11) AS SHOWN ON PLANS. 20 REMOVE (E) 12" CMP AS SHOWN AND INSTALL (N) 12" HDPE PIPE. TRENCH SECTION SHALL BE PER ENGINEERING STANDARD 6025, WITH 12" AC OVER 1 -SACK SLURRY BACKFILL. REALIGN AT CARPENTER AS SHOWN, INSTALL 45° BEND. CAUTION: UTILITY LINES CROSS (N) STORM DRAIN LINE ON FOOTHILL. VERIFY CLEARANCE PRIOR TO CONSTRUCTION. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. 21 ABANDON (E) 12" CMP AS SHOWN AND INSTALL (N) 12" HDPE PIPE PER PLAN. TRENCH SECTION SHALL BE PER ENGINEERING STANDARD 6025, WITH 12" AC OVER 1 -SACK SLURRY BACKFILL. CAUTION: GAS LINE IN AREA RUNS PARALLEL TO (N) STORM DRAIN ON CARPENTER. VERIFY CLEARANCE PRIOR TO CONSTRUCTION. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. 22 CONNECT (N) PIPE TO (E) 54" CMP STORM DRAIN, INSTALL GROUT COLLAR AT CONNECTION. 23 CONTRACTOR TO INSPECT CONDITION OF (E) 54" CMP STORM DRAIN AT MANDATORY PRE -BID WALK- THROUGH. REHABILITATE BOTTOM OF. PIPE UNDER STREET AND EASTERLY SIDEWALK (42') PER PAVED INVERT DETAIL THIS SHEET. (,n I I II I I I Cf) 0 I II I cp 0 II II I I I cn 0 I� m. �I �IC)l �In Imo cn I I I 21 I (275.53 RIM) 3 (272.58 INV) �OHW— — — \ Q o EX. CB HW- - J - -OHW w — — — G — — — — — — G — — — — — Q I 2.5' min. U U m 8.5' ^I � U 4— 12' CMP Li `I— G — G G G(E) 4" GAS GE PCC JUNCTION BOX o Q (N) CATCH BASIN 17 �� (267.11 INV S) I I (270.51 INV E) I N 2304394.24 (E) 6" SEWER 278.75 W S — — — — — S — — — — — — — S z o REM VE (E) 12" C P 23 I I I 279 (E) 6" UNION OIL GAS FUEL LINE (26" COVER) I G G G G — — — — — G — — — — — G Q STORM DRAIN —W— — — — —W— — — — —W— — — — —W— — — — —WEE) g -„ CI WA I I CD I < � I � z �G GRADE (E) CATCH BASIN TO REMAIN Q � � I o w a ABANDON 0 (E) 12" CMP \ STORM DRAIN, CAP EN 27E.45 V _ -- \ ( E) R A D E _ o OPE i ±5 0 4 DRAIN, 274 � � — (N) 2" HDPE STORM — — 12" C OVER 11-SACK SLURRY BA KFILL AT TRENCH 27020 . INS LL (N) 45° BEND NOTE 22 INV CONSTRUCTION Q 269 FOR CONNECTION REHABILITATE BOTTON OF INV 3?±267.1 PIPE PER PA ED INVERT DETAIL PROFILE AT FOOTHILL - CARPENTER Know what's below. Call before you dig. MATCH (E) 279.05) TC 278.55) FL 278.75 RIM 275.45 INV N 2304497.95 E 5767291.88 Q W= 4.0' 'n 06 J J O O LL o v o I 11 I II I I 0 I l I I I — I d I I I II I I I I� I I I I I I I I 11 I — — I W- I, cra I 278.88 TC 2 278.p0 FL 1j (278.37 TC)' ` 277.87 FL) I I I MATCH (E) I I c/) IILiI I Lj I 17 �I QI i 0 tI — rH I� —OIHW- I� I ILu IN I I� I I I I I G - I I I S ,� �� e Q cj� � I I I I I I I I I cn I I W� - - - -W -- � I IU I wl I Li LiI I � I w1 I � I I I I I I I I U) I I I I 111 I I I — I I I I I I I I DO, I I —ea CONSTRUCTION NOTES OPROTECT IN PLACE. 11 REMOVE (E) AC PAVEMENT AND REPLACE PER ENGINEERING STANDARD 6025. 17 RESTORE DISTURBED STRIPING AND PAVEMENT MARKINGS. 18 RELOCATE (E) 1" COPPER WATER LATERAL PER ENGINEERING STANDARD 6210. VERIFY LOCATION WITH ENGINEER PRIOR TO INSTALLATION. REPLACE (E) WATER METER BOX AND LID WITH (N) BOX AND LID. S REMOVE (E) STORM DRAIN STRUCTURE AND INSTALL (N) CATCH BASIN PER ENGINEERING STANDARD 3355, CURB FACE OPENING PER PLAN. CONNECT (N) STORM DRAIN PIPE TO (N) STRUCTURE. PRIOR TO CONSTRUCTION, VERIFY LOCATION AND DEPTH OF NEARBY GAS LINE. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. CONTRACT PRICE INCLUDES REMOVING AND REPLACING CURB, GUTTER & SIDEWALK AS SHOWN ON PLANS AND (N) AC PAVEMENT (NOTE 11) AS SHOWN ON PLANS. 20 REMOVE (E) 12" CMP AS SHOWN AND INSTALL (N) 12" HDPE PIPE. TRENCH SECTION SHALL BE PER ENGINEERING STANDARD 6025, WITH 12" AC OVER 1 -SACK SLURRY BACKFILL. REALIGN AT CARPENTER AS SHOWN, INSTALL 45° BEND. CAUTION: UTILITY LINES CROSS (N) STORM DRAIN LINE ON FOOTHILL. VERIFY CLEARANCE PRIOR TO CONSTRUCTION. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. 21 ABANDON (E) 12" CMP AS SHOWN AND INSTALL (N) 12" HDPE PIPE PER PLAN. TRENCH SECTION SHALL BE PER ENGINEERING STANDARD 6025, WITH 12" AC OVER 1 -SACK SLURRY BACKFILL. CAUTION: GAS LINE IN AREA RUNS PARALLEL TO (N) STORM DRAIN ON CARPENTER. VERIFY CLEARANCE PRIOR TO CONSTRUCTION. COORDINATE WITH UTILITY COMPANY TO RELOCATE AS NECESSARY. 22 CONNECT (N) PIPE TO (E) 54" CMP STORM DRAIN, INSTALL GROUT COLLAR AT CONNECTION. 23 CONTRACTOR TO INSPECT CONDITION OF (E) 54" CMP STORM DRAIN AT MANDATORY PRE -BID WALK- THROUGH. REHABILITATE BOTTOM OF. PIPE UNDER STREET AND EASTERLY SIDEWALK (42') PER PAVED INVERT DETAIL THIS SHEET. (,n I I II I I I Cf) 0 I II I cp 0 II II I I I cn 0 I� m. �I �IC)l �In Imo cn I I I 21 I (275.53 RIM) 3 (272.58 INV) �OHW— — — \ Q o EX. CB HW- - w I LJ I o <I I I I I �I I °I i 0 0I o� CD i I Q0 I / �I Q I I w 1 0 I QI >I Im uI I / olrn cock _ � SCALE: 1 " =10' o j I Q i I 0 10 20 U, I I OHW - - - -OF G — — — G — — — — S6Ej 22 "x13" CMSPD = ARCH — — SD — — S — — — — — S — — — — S ri - - -OHW w — — — G — — — — — — G — — — — — I 2.5' min. 8.5' ^I SE) 12' CMP Li `I— G — G G G(E) 4" GAS GE PCC JUNCTION BOX 3 (275.61 RIM) 17 �� (267.11 INV S) I I (270.51 INV E) I N 2304394.24 (E) 6" SEWER E 5767299.49 —I — S — — — r S — — — — — S — — — — — — — S I CD 23 I I I (E) 6" UNION OIL GAS FUEL LINE (26" COVER) I G G G G — — — — — G — — — — — G I&_ W— I— —i — —W— — — — —W— — — — —W— — — — —W— — — — —WEE) g -„ CI WA I I CD I � I � � � � I w I LJ I o <I I I I I �I I °I i 0 0I o� CD i I Q0 I / �I Q I I w 1 0 I QI >I Im uI I / olrn cock _ � SCALE: 1 " =10' o j I Q i I 0 10 20 U, I I OHW - - - -OF G — — — G — — — — S6Ej 22 "x13" CMSPD = ARCH — — SD — — S — — — — — S — — — — S ri — @ 4) -6-FH -- W — — — — — C� CARPENTER STREET LO r O N N H Z W W V Q J a w a 2 v ui ui � J o w a vi Lu z Lu n L.L Q U i O LL DESIGNED BY: JL DRAWN BY: PS /JL CHECKED BY: DA APPROVED BY: BL SCALE: H: 1" = 10' V:1 " =2' DATE: JUNE 2016 CITY SPECIFICATION NO. 91268 PLAN FILE NO. / LOCATION SHEET NO. 4 af4 — — — G — — — — — — G — — — — — @ 4) -6-FH -- W — — — — — C� CARPENTER STREET LO r O N N H Z W W V Q J a w a 2 v ui ui � J o w a vi Lu z Lu n L.L Q U i O LL DESIGNED BY: JL DRAWN BY: PS /JL CHECKED BY: DA APPROVED BY: BL SCALE: H: 1" = 10' V:1 " =2' DATE: JUNE 2016 CITY SPECIFICATION NO. 91268 PLAN FILE NO. / LOCATION SHEET NO. 4 af4 Lu z Lu n L.L Q U i O LL DESIGNED BY: JL DRAWN BY: PS /JL CHECKED BY: DA APPROVED BY: BL SCALE: H: 1" = 10' V:1 " =2' DATE: JUNE 2016 CITY SPECIFICATION NO. 91268 PLAN FILE NO. / LOCATION SHEET NO. 4 af4