Loading...
HomeMy WebLinkAbouth Update on Registration and InspectionRental Housing Inspection Program Update on Registration and Inspections The following is an update on the registration and inspection activity for the RHIP through January 31, 2017, along with the number forecasted when the ordinance was adopted. Registrations Total to 1/31/17 Forecasted at Adoption for FY16-17 # of units registered 3329 (76%) 3255 # of units filed for exemption 793 (15%) # of suspected units not registered 1029 (23%) Inspections Total to 1/31/17 Forecasted at Adoption for FY 16-17 # of units inspected 915 1754 # of units passed on first inspection 152 (16%) # of units passed on second inspection 422 (46%) 794 # of units with corrections not yet completed 341 (37%) # of no shows 51 (5%) # of code cases created 4 # of properties with illegal construction 94(10%) # of units where tenants refused inspection 158(14%) 3329 793 1029 Registered Exemptions Not Registered Inspections and Inspection Checklist The Inspection Checklist reflects California Health & Safety Code Section 17961, which requires local building department or housing agencies to enforce the provisions of the State Housing Law pertaining to the maintenance, sanitation, ventilation, use or occupancy of residential structures. Health & Safety Code Section 17920 defines the term “enforcement” as follows: (e) “Enforcement: means diligent effort to secure compliance, including review of plans and permit applications, response to complaints, citation of violations, and other legal process. Except as otherwise provided in the part, “enforcement: may, but need not, include inspections of existing building on which no complaint or permit application has been filed, and effort to secure compliance as to these existing buildings.” As noted in the last sentence, enforcement may include proactive inspections of existing building where no complaint has been filed. As of January 31, 2017, staff has conducted 915 inspections. Below is a copy of the inspection checklist showing the number of times specific corrections were needed and the percentage based on the total inspections performed. 915 152 422 341 0 100 200 300 400 500 600 700 800 900 1000 Inspections Total Inspection No corrections needed Corrections Completed Corrections Outstanding     Rental Housing Inspection Program Inspection Checklist Community Development T 805.594.8189 919 Palm Street, San Luis Obispo, CA 93401-3218 F 805.781.7173 Case #: _________________ Date: ________________ Property Address: Part 1- Exterior Passed Needs Correction Corrections Identified as of 12/31/16 Premises – no abandoned or inoperable vehicles, overgrown vegetation, infestation of insects or vermin, discarded household items, trash debris or any graffiti. Premise identification installed on building. 63 (7%) Exterior Walls – no peeling paint, holes, missing sections or deterioration. 46 (5%) Vent Screens – no missing or damaged crawl space, attic or foundation vent screens. 77 (9%) Stairway/Landing/ Guardrails/Handrails – well secured, not deteriorated. Handrails provided for 4 steps or more. 25 (3%) Roof and Ceilings – without any leaks 16 (2%) Exterior Lighting – functions and have proper covers, no exposed wiring. 24 (3%) Electrical Panel –all breakers/fuses are labeled and there is no exposed wiring. 188 (22%) Garage – Is used for its permitted purpose. 46 (5%) Entry Doors – all doors and door jambs have strike plates that are secure. entry doors open and close easily and able to be unlocked without a key from interior; weather sealed. 16 (2%) Part II: Interior Windows – windows can be opened and closed easily, lock and have no missing or broken glazing. Bedrooms have escape/rescue windows and are not blocked. Any security bars/screens can be released from the interior. 31 (4%) Heaters – are permanently installed and properly functioning. Able to heat room to 68° 17 (2%) Kitchen Counters and Sink Surfaces –No significant cracked or missing pieces. 12 (1%) Floor/Subfloor – Not defective or deteriorating to cause a trip hazard. Free from signs of buckling or sagging. 17 (2%) Property Address: _____________________________ Page 2   Plumbing/Piping –without leaks or clogs, no missing handles or spouts. Hot water required in the kitchen and bathrooms. 70 (8%) Water Heaters – installed in approved location, have seismic strapping, operable relief valve & drain line. Minimum 120 water temperature 234 (27%) Bathroom Ventilation – operable window or exhaust fan. 9 (1%) Smoke Detectors – working, and located in each bedroom, in hallways leading to bedrooms and on each level of unit. 266 (31%) Carbon Monoxide Detectors – located outside each sleeping area & on each level of unit (including basements). 237 (28%) Electrical – general outlets, lights, switches and cover plates are installed properly with no exposed wiring. GFCI required locations: bathrooms, kitchen counters, exterior of the building and in garages. Only required where outlets have been upgraded. 280 (33%) No change in any portion of a building, structure, common area or any other work regulated by Code shall be required when such work was installed and is maintained in accordance with the Code in effect at the time of installation. A completed Rental Housing Inspection Checklist does not certify that any work done to the building or structure was in compliance with any permit or approval requirements. I certify that I have inspected the aforementioned unit and that the information above is true and correct to the best of my knowledge. Name of Inspector: _____________________________________ Date: _______________________ Additional Inspection Comments: Amnesty Amnesty allows owners to obtain the permits (if required) to bring properties into code compliance without having to pay the additional penalties and additional fees that would otherwise apply to correct unpermitted work or substandard conditions. Amnesty Total to 1/31/17 Status # of properties filed for amnesty 65 # of properties that have completed the amnesty process. 7 Building permits issued and inspected. # of properties which filed but didn't need amnesty 8 Staff determined there was no unpermitted work on the property. # of properties working on obtaining building permits 17 # of properties where additional information is needed 19 These property owners have not responded to requests for additional information # of unpermitted units 14