HomeMy WebLinkAboutCouncil Reading File - Monterey and Osos Traffic Signal - Plans 91377enera notes: index to plans 1 . IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR PERMITTEE TO CONTACT "UNDERGROUND SERVICE ALERT OF O \ sheet no. description NORTHERN CALIFORNIA" BY PHONE AT 8-1-1 FORTY-EIGHT (48) HOURS PRIOR TO START OF CONSTRUCTION FOR LOCATION OF POWER, TELEPHONE, OIL AND NATURAL GAS UNDERGROUND FACILITIES. CONTRACTOR OR PERMITEE SHALL ALSO CONTACT THE APPROPRIATE AGENCY FOR THE LOCATION OF CABLE T.V., WATER, SEWER, DRAINAGE OR UNDERGROUND FACILITIES. \ \\ I COVER 2 DEMOLITION 2. THE CONTRACTOR SHALL POSSESS A CLASS "A" OR "C-10" LICENSE AT THE TIME THE CONTRACT IS AWARDED. / � 3 SIGNAL INSTALLATION 4 O 7P CURB RAMP INMPR O VEMENTS O O o P O O BASIS OF B GS COORDINATES FOR THIS PROJECT ARE CALIFORNIA 0 3 COORDINATE SYSTEM NAD83, ZONE 5, US SURVEY FEET, AS DETERMINED BY GPS OBSERVATIONS ON POINT 8013 AS SHOWN ON THE CITY OF SAN LUIS OBISPO "HORIZONTAL CONTROL j NETWORK" (JANUARY 2007). J \ P BENCHMARK THE ELEVATIONS SHOWN HEREON ARE NAVD88 AS DETERMINED BY GPS OBSERVATIONS ON POINT 162 AS SHOWN ON THE CITY OF SAN LUIS OBISPO "BENCHMARK SYSTEM" (JANUARY 2007) HAVING PUBLISHED ELEVATION OF 250.65'. \ Reference Documents: City Standard Specifications - January 2016 Edition City Engineering Standards - January 2016 Edition O \� N � � P \ ij72 == 0 san lues coup obisp o lf ornia �J'� caf 0 0 MONTEREY AND OSOS TRAFFIC SIGNAL RECONSTRUCTION 0 \ /\ O��O Q?,OF ESS/0 Q�pF ESSlO ��EW AyglF ��O ANEW RC 9l� \0 m c-1 m No. C 63611 * * No. C 73868 CIV 1\-\P S% CIV grFOF CAS\Fq�FOF CAS\F��� \ Approved: O P SPECIFICATION NO. 91377 \ DATE MAY 2016 APPROVED BY FILE NO./LOCATION 91377 Barbara Lynch R. C.E. C053418 City Engineer SHEET 2015 1 4 OF W CONSTRUCTION DEMOLITION NOTES: W =- _• I I I I I 1❑ PROTECT IN PLACE EXISTING VAULT "'' - • 4 SAWCUT LINE n/ 2❑ DEMOLISH AND/OR REMOVE SIGNAL POLE FOUNDATION � IIi� �III�� Iiilll L� AS NECESSARY TO INSTALL NEW SIGNAL POLE FOUNDATION. SALVAGE SIGNAL POLE AND EQUIPMENT CITY TO CORPORATION YARD AT 25 PRADO ROAD 3❑ REMOVE EXISTING PULLBOX ® REMOVE TRAFFIC SIGNAL POLE AND FOUNDATION NECESSARY FOR NEW SIGNAL POLE INSTALLATION 3❑ uJ REMOVE EXISTING TREE AND TREE WELL ❑1 ' O © PROTECT AND RE—USE EXISTING TRASHCAN AND PLACE IN FIELD O I u� 7❑ AS DIRECTED BY CITY REPRESENTATIVE PROTECT AND RE—USE EXISTING BENCH AND PLACE IN FIELD ' 3❑ _ _ _ W Q � I 2❑ 0 ® AS DIRECTED BY CITY REPRESENTATIVE REMOVE EXISTING PARKING METER O I Q 2❑ _ � PROTECT IN PLACE 9 ❑ PROTECT AND RE—USE EXISTING BIKE RACK AND PLACE IN FIELD AS DIRECTED BY CITY REPRESENTATIVE ` MONTEREY S EXISTING CURB 10 REMOVE AND SALVAGE DECORATED SIGNAL CONTROLLER BOX TO THE CORPORATION YARD AT 25 PRADO. CHECK WITH KELLY LINDSAY AT 805-781-7032 REGARDING ANY I SAWCUT LINE D ADDITIONAL CABINET SIGNAL EQUIPMENT TO BE SALVAGED PROTECT IN PLACE -11 AND DISPOSE OF ANY ADDITIONAL EQUIPMENT. EXISTING CURB J W Fl REMOVE SIDEWALK AS SHOWN I'm 12 REMOVE CONCRETE ROADWAY AS SHOWN U.U. M OR TER E E E T cn J Q Z 0 MONTEREY STREET 44'- - V o LLo LL E 0 8 16 I MONTEREY S I I Q oc o I � 1 INCH - 4 FEETcn I O 4„L I I I cn I p 1 ! ��a 1 I REMOVE CONFLICTING STRIPING 23' I , W I W 4 4' H - I Z I 0 � I � � w J I O Lu w SAWCUT LINE , I 0- cn FZpFESS/0 Nql NEW REl I 2❑ © SAWCUT LINE O I ❑ I . c�,�NF� 19 ��� W I w m * No. C 73868 I C IV J\' FOF I CAS\F Month Day, Year DESIGNED BY: MRC II 10 DRAWN BY: MRC CHECKED BY: I 12' APPROVED BY: SAWCUT LINE O , ii SCALE: 1. 5'AS NOTED DATE: O I JUNE, 2016 CITY SPECIFICATION NO. 91377 v / 0 PLAN FILE NO. / LOCATION SHEET NO. 2 of 4 CON STRU CT ON NOTES: 0 REMOVE EXISTING CONTROLLER FROM CABINET AND FURNISH AND INSTALL A MODEL 170E CONTROLLER INTO TYPE 332 CABINET, COMPLETE WITH MCCAIN TYPE 233 PROGRAMMING, C2S WIRING HARNESS, COMM. BLOCK FOR COMMUNICATION, AND ALL APPURTENANCES REQUIRED TO PROVIDE THE INTENDED OPERATION. 2❑ INSTALL CALTRANS TYPE III -A MEYERS MEUG12 SERVICE ENCLOSURE PER SLO STD. PLAN 7510 OR APPROVED EQUAL. 3❑ INSTALL CALTRANS STANDARD SIDE MOUNTED BATTERY BACKUP CABINET, MEYERS MP2000ER BATTERY BACKUP SYSTEM (BBS) WITH POWER TRANSFER SWITCH (PTS), MANUAL BYPASS SWITCH (MBPS), BATTERY CABLES, 30 AMP GENERATOR PLUG KIT, INSTALLATION WIRES, FOUR (4) 79AH BATTERIES AND OTHER ASSOCIATED HARDWARE TO NECESSARY FOR A WORKING BBS SYSTEM OR AN APPROVED EQUAL SYSTEM. ® FURNISH AND INSTALL ITERIS VANTAGE EDGE2 VIDEO DETECTION PROCESSORS IN CONTROLLER CABINET INPUT FILE. 5❑ INSTALL ITERIS COLOR VIDEO DETECTION CAMERA (RZ4-AWDR) ON LUMINAIRE ARM. INSTALL BELDIN 8281 CABLE FROM CAMERA TO SIGNAL CABINET. CAMERA TO BE POWERED DIRECTLY TO THE BATTERY BACKUP SYSTEM THROUGH THE TERMINAL BLOCK WITH DLC CABLE. © FURNISH AND INSTALL EMERGENCY VEHICLE PRE-EMPTION DETECTOR PER "DETAIL A". 7❑ FROM THE EXISTING COMMUNICATION MANHOLE, CAREFULLY REMOVE THE EXISTING SIC FROM CONDUITS LEADING TO THE EXISTING CONTROLLER. CONTRACTOR SHALL THEN CUT EXISTING SIC SO THAT IT CAN REACH THE NEW CONTROLLER CABINET AT THIS INTERSECTION. UPON COMPLETION OF INSTALLATION OF NEW CONDUITS, PULL BOXES AND CONTROLLER AT THIS INTERSECTION, REINSTALL THE SIC, AS INDICATED ON PLAN IN CONDUITS LEADING TO THE NEW CONTROLLER. PROVIDE 10' OF SLACK IN CONTROLLER. CONTRACTOR SHALL INSTALL A NEW SIC IF THE EXISTING SIC IS DAMAGED DURING THE CONSTRUCTION. CONTACT BRYAN WHEELER AT (805) 781-7178 TO COORDINATE CONNECTION. ® INSTALL ENCOM 5.8 GHz RADIO USING PELCO ASTRO-BRAC (#AB -0121-42) AS MOUNTING HARDWARE AND ANTENNA PIPEWORK (#M1046). INSTALL CAT 5 CABLE FROM ENCOM RADIO INTO SIGNAL CABINET TO ITERIS EDGECONNECT CABINET HUB AND COIL EXCESS CABLE LEFT OVER FROM TOTAL CABLE LENGTH SUPPLIED WITH RADIO (10' MAXIMUM). 9❑ INSTALL CALTRANS STANDARD PUSH BUTTON ASSEMBLY POST, PER STD. PLAN ES -7A, WITH POLARA APS PEDESTRIAN PUSH BUTTON ASSEMBLY, OR APPROVED EQUAL. 10 INSTALL POLARA APS PEDESTRIAN PUSH BUTTON ASSEMBLY, OR APPROVED EQUAL. CO D PMETER G © PARKING ❑ �PM KI G METER 4' L I I 417U I I L ----J 105' BIKE,- ACK24"24,. O 11 10 II II 5 II II I I I I I I I I I i Ln I I I I I I I I 0 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —D I I (D I I (-D I I I II I I I I I I I I I I I I I I I I © I I I I I I I I I I I I I I I I I I I I I I I I Ti7 - - J NO2 08 ----------------- -08 416 L �J i L---------------------------------- iJ ---------- Iti 418UIL II --- II II II BIKto O IKE RAoCK 24 II, \ C B o 06 CONDUCTOR SCHEDULE AWG❑R SIZE POLE OR IF D D � I ©D I � I 2 I CD I CABLE TYPE L ----J 1 1 I I I I I I I I I i Ln I I I I I I I I 0 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —D I I (D I I (-D I I I II I I I I I I I I I I I I I I I I © I I I I I I I I I I I I I I I I I I I I I I I I Ti7 - - J NO2 08 ----------------- -08 416 L �J i L---------------------------------- iJ ---------- Iti 418UIL II --- II II II BIKto O IKE RAoCK 24 II, \ C B o 06 CONDUCTOR SCHEDULE AWG❑R SIZE POLE OR 2 D D ®D 1 ©D #10 ®O 2 1 D CABLE TYPE CIRCUIT 1 1 12' TOTAL #10 6 3 3 2 2 1 2 2 CAT 5 LUMINAIRE 4 2 2 1 1 1 1 #10 SIGNAL COMMON 2 1 1 1 1 1 1 1 12' TOTAL #10 6 3 3 2 2 1 2 2 PBAP 6 --t> CO 17-2-100 20' 12' MAS SV -1—T SP -1—T 6 94W DO 1 A (10') TV -1—T SP -1—T 8 ©�IIIIIII%IIIIII%IIIIFAA OE 17-2-100 20' 12' MAS SV -1—T FAA M IN PAN N M I FAAF M FAA CAT 5 LUMINAIRE 4 2 2 1 1 1 1 #10 SIGNAL COMMON 2 1 1 1 1 1 1 1 12' TOTAL #10 6 3 3 2 2 1 2 2 CAT 5 VIDEO SERVICE 4 2 2 1 1 1 1 #12 VIDEO CABLE—BELDIN 8281 4 2 2 11 0 1 1 12' TOTAL 12 87-4 SP -2—T 4 2 2 2 2 CAT 5 ENCOM VIDEO I I I 1 I 1 I 1 I 1 I 1 EVP I OPTICOM 138 DETECTOR 4 1 2 1 2 Lum M.A. rim CONDUIT SIZE 2" 2" 2x4"2x4"2x3" 4" 3" 2" 3" 2" 2" ALL CONDUITS AND CONDUCTORS ARE NEW UNLESS OTHERWISE INDICATED BY AN (E) I 08 b 02 06 0- 04 N b `' �4 P PROPOSED PHASE DIAGRAM 0 20 40 1 INCH = 10 FEET D D A 08 9 I I Fix N C -j:02 8P 04 M A POLE AND EQUIPMENT SCHEDULE N0. STANDARD VEH SIG MTG PED SIGNAL PPB LED LUMINAIRE R.S.N.S Type Sig M.A. Lum M.A. A°m Pole MTG f6 ARROW 0 17-2-100 20' 12' MAS SV-2—TB SP -2—T 4 <1-- 94W BO PBAP 6 --t> CO 17-2-100 20' 12' MAS SV -1—T SP -1—T 6 94W DO 1 A (10') TV -1—T SP -1—T 8 OE 17-2-100 20' 12' MAS SV -1—T SP -1—T 8 94W MONTEREY 0 1 A (10') TV -1—T SP -1—T 2 --t> © 17-2-100 1 20 12' MAS SV -1—T SP -1—T 2 <-- 94W OSOS OH 1 A (10') TV -1—T SP -1—T 4 *ALL POLES AND ASSOCIATED EQUIPMENT ARE NEW (N) **S.N.S. SHALL BE RETROREFLECTIVE PER SLO ENGR. SSTD PLAN 7250, DIAMOND GRADE SHEETING OR BETTER AND MOUNTED PER CALTRANS STD ES70 AND ES7D. ------------------------------------------------ 8J8U I I L---------------------------------------------------J 8 J 8 L I I- ----------------------- 6 0' PARKING METER GENERAL NOTES: • DETECTOR H MAST ARM MOUNTING CLAMP (OPTICOM MODEL 722) U (PELCO N0. AB -121) 0 VLEVEL MAST ARCATE EVPE DETECTOR ON PART OF MAST ARM DETAIL A EMERGENCY VEHICLE PRE-EMPTION DETECTOR TRAFFIC SIGNAL MAST ARM MOUNTING DETAIL EMERGENCY VEHICLE PREEMPTION EVA = 02 EVB=04 PARKING METER EVC = 06 EVD = 08 105 8J7U ++ I 4' 1 . ALL WIRING SHALL BE MARKED (TAGGED) WITHIN THE CONTROLLER CABINET AND ALL PULL BOXES FOR PHASE/POLE IDENTIFICATION. 2. ALL SIGNAL EQUPMENT SHALL BE WIRED IN ACCORDANCE WITH THE PHASE DIAGRAM. 3. CONTROLLER CABINET, SERVICE PEDESTAL, AND POLE LOCATION SHOWN HEREON ARE APPROXIMATE, PRECISE LOCATIONS SHALL BE ESTABLISHED IN THE FIELD AND VERIFIED BY THE ENGINEER PRIOR TO SAW CUTTTING AND/OR INSTALLING NEW SIDEWALK. 4. THE CONTRACTOR SHALL GIVE 10 WORKING DAYS NOTICE TO THE ENGINEER PRIOR TO SIGNAL TURN ON. TURN ON PROCEDURE SHALL FOLLOW SPECIAL PROVISIONS. 5. CONTRACTOR SHALL RESTORE ANY UTILITY IF DAMANGED PER CITY ENGINEER'S REQUIREMENT. 6. CONTRACTOR SHALL WORK IN ACCORDANCE WITH THE MOST RECENT EDITIONS OF THE CITY OF SAN LUIS OBISPO CITY STANDARD SPECIFICATIONS AND ENGINEERING STANDARDS AND THE 2010 CALTRANS STANDARD PLANS AND SPECIFICATIONS. 7. CONTRACTOR SHALL PROVIDE ALL NEW ELECTRICAL CONDUCTORS/CABLES. 8. NO SPLICES SHALL BE ALLOWED IN SIGNAL INTERCONNECT CABLE. 9. THE CONDUCTOR SCHEDULE IS PROVIDED AS AN INSTALLATION GUIDELINE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE APPROPRIATE NUMBER OF CONDUCTORS REQUIRED FOR THE INTENDED OPERATION. W Q M W LL cn J Z 0 U) U U. Q 0 co O 06 W W F - z O w � J H H H U W O of P- 17P gt# W J H F– W w co Q�pFESslo O corn w M * No. C 63611 C IV OFC DESIGNED BY: BRW DRAWN BY: BRW CHECKED BY: MRC APPROVED BY: MH 1 SCALE: AS NOTED DATE: NOVEMBER, 2015 CITY SPECIFICATION NO. 91377 PLAN FILE NO. / LOCATION SHEET NO. 3 of 4 CONSTRUCTION NOTES: W _- - =- 0 PROTECT IN PLACE EXISTING VAULT. W6S 90 SAWCUT LINE jr3 99 i� fpfa5 ❑ MINSTALL TRUNCATED DOMES PER CITY STANDARD 4440 n/ I� RT v - o - W ❑3 INSTALL 10" AC PAVEMENT PER CITY STANDARD 4110 • 469 l 0 ® REMOVE TRAFFIC SIGNAL POLE AND FOUNDATION NECESSARY FOR g . °'� Ae� g. 6,� NEW SIGNAL POLE INSTALLATION - �6 - �.Jg gAF� p g _ g� ❑5 REINSTALL EXISTING BENCH PER CITY STANDARD 9040 g P ${ y g r 0 0 o 0 0 g� g �' I0O00000 g © PLANT NEW FICUS MICROCARPA IN NEW 36" TREE BOX PER CITY STANDARD 8250, AND INSTALL TREE GRATE AND TREE GAURD PER �� g r g Peg 0000°0°0°per , �0* CITY STANDARD 8130 X43 9 0 °s g a 0000000 4: "' 2❑ 0000°0 O '' . g - w ,00 0000, 7 REMOVE EXISTING SIDEWALK AND AC PAVEMENT TO THE F O0oo0o°c g ,000oo, p �' Q .,o ® 9xY r g JOO 00000 0000000000 000000000 X00000000000 u ® EXTENTS SHOWN REINSTALL BICYCLE RACK PER CITY STANDARD 7930 r n v / T� 000000 g g 0000000 0o0000c v 000000 ... g . a 00000000000 re x 0000 000000 0 �• a FO) D0000000p ° 0 000000 0 ❑9 PAINT RED RED CURB 0 *Av 0,00,0 0000000 g ._ v- 000000c, J II ,°0°O - r n 10 REINSTALL EXISTING TRASH CONTAINER PER CITY STANDARD 9060 TO BE LOCATED BY CITY ' 00000000. 000000, g 000000000 0 00000000o V* v J 0000000000-0, -c Sj "OFsgp 0 11 INSTALL ROADWAY SECTION PER CITY STANDARD 6020 CASE 2. ,000000000000, p 00°0° 000000°0° 000`00 A �A SAWCUT LINE �aFo MONTEREY STREET 000000000000 °° ����� ��000 ��� �� o 00 000000000000 g ' Lu c: • / %i410 LLI..L T co O MONT-F�REY 'STREET4-0 J 4-r a z 0c: E v MONTEREY Sum U. MONTEREY S 0 a 0 8 16 '4" 1 INCH = 4 FEET 11 Ln I� 0 g I 06 (/�/� �/ / ' 223.78 FL/EC 224.09 TC/EC I (14.8',13.9') w �99 g * �y 223.83 FL I A/ LL g�A0 1747'4 4 2' ( ) w J pg g g x`22 223.61 FL/EC 223.68 FL S'FT`392 223.61 TC/EC 223.68 TC %FLC R10' 223.93 FL/BC 224.25 TC/BC (23.0',12.6') R20' I 13 FL/BC I224.47 TC/BCBC z O ?, 3� (0.2,9.9) 11 T ��g 9 (.. 224.15 FL I " Ftia 3 a 1g 224.49 TC CONFORM (35.5',9.2') bi Lu J I g3. 00 o0po °ooq ° ° ° °. a w w 00p 0000 00001, 0000000000'' ° ° w 2 U) SAWCUT/ LI -N E g g3s0 os 0 000OOO 00°°n- OOOOOO0 0 0 00. 00 000- 0C> -- 00 ESRS./p Fw-, 000 00 0 0000on 0000 ° ,°00 oo000000000000bf0 I .NOEFW CN,A'9 �F 0 00000000002 000 000 0 T Z--:0223.44 o°°00°0rn 223.44 FL BC 0000 Y TC/BC 0000.r II o f0 o SAWCUT LINE II No. C73868W 0 g 000000, .2,0.2) 000000 Ln 000000c 0 00 000 0, O c ,0,0) X � o I�II 224.56 CONFO?2,9 RM TO EXISTING AT CIV 1\1 P FOF C I f L� ' -- 2.0 % 1.0� If1 .0' ° ° °.. °. ° . ° .° °. ° °. a °. ° I SCORE LINE 23 Month Day, Year (99 DESIGNED BY: ° S MRC p g qd . J �� 388 223.89 W I BLDG AP/GB DRAWN BY: MRC � c ?460 W 11 CHECKED BY: v g g VI. g 0 ° ° ° ii APPROVED BY: . _ c 222.91 FL SCALE: O 223.44 BSW ASE I 223.36 TC I (1.3',-13.1') AS NOTED SAWCUT LINE (-7.1 ,-13.1)CONFORM CONFORM i DATE: JUNE, 2016 >r - 1.4% CITY SPECIFICATION NO. 91377 0 PLAN FILE NO. / LOCATION un SHEET NO. 0 4 of 4