Loading...
HomeMy WebLinkAboutCouncil Reading File-91288 Calle Joaquin Park & Ride Plan SetHDPE 362 lf HIGH DENSITY POLYETHYLENE EDGINGTREESQTYBOTANICAL NAMECOMMON NAMECONT 10Platanus racemosaCalifornia Sycamore15 gal 13Tristania confertaBrisbane Box15 galSHRUBSQTYBOTANICAL NAMECOMMON NAMECONT 95Juncus patens `Carmens Gray`Carmen`s Gray Rush1 gal 60Lantana camara `Radiation`Radiation Lantana1 gal 40Lavandula stoechasSpanish Lavender1 gal 72Muhlenbergia rigensDeer Grass1 gal 21Rhamnus californica `Eve Case`California Coffeeberry5 gal 93Rhaphiolepis indica `Ballerina Pink Dancer`Indian Hawthorne Ballerina Pink Dancer5 gal 303Teucrium x lucidrys prostratumProstrate Germander1 galGROUND COVERSQTYBOTANICAL NAMECOMMON NAME 5,641 sfBARK MULCHWALK ON BARK MULCHSpread 3-inches deep in all Planter AreasPLANT SCHEDULEO:\PRJ\1955\1955LSP001.dwg 5/22/2017 8:40:20 AMCALLE JOAQUIN PARK-N-RIDE LOTCITY SPECIFICATION NO.5/25/17DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.13DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSLO CITY BDR LAST UPDATED 8-11-15 91288NORTH0SCALE: feet2040601" = 20'GENERAL PLANTING NOTES1.QUANTITIES: The plant quantities are providedfor the convenience of the owner. The contractorshall verify all plant counts between the plant listand the plans. If a discrepancy exists, the plansshall govern. Notify Landscape Architectimmediately if materials are not available asspecified. All substitutions are subject to thewritten approval of the record LandscapeArchitect. Install plant materials per details.2.The Contractot shall notify the City Arborist atleast (5) five working days prior to any treeplanting operations to arrange for inspection andobservation of tree plantings.3.SOILS TEST: Contractor shall obtain a soils test(Soil Management Report) from at least fourdifferent locations within the project area after sitedevelopment grading is complete. Soil test resultsshall be provided to the landscape architect andowner for their records. Soil amendments shall beas recommended by the soils report to correct soildeficiencies.4.AMENDMENT: At minimum, areas receivingground cover plant materials or sod grass, shallreceive (roto-tilled into the soil to a depth of8-inches) at a minimum 3-yards per 1,000 sfnitrified or composted forest mulch.5.PRE-EMERGENT: A pre-emergent herbicide(Ronstar-g, Surflan, or equal) shall be applied toall non-turf landscaped areas before applyingsurface mulch.6.FINISH GRADE: Finish grade all planter areas toestablish a smooth, even finish. Remove all rocksor debris larger than 1-inch in diameter.7.DRAIN INLET ROCK MULCH: LandscapeContractor responsible to place 3"-6" size cobblerock mulch (with filter cloth) around all drain inlets(2-ft. around) in planter areas (not containingmowable turf) to mitigate clogging from barkmulch. See Civil plans for storm drainage.8.FINISH GRADE IN PLANTERS: All planter fingersand self contained planters in the parking areasshall be prepared so that the planter soil is within3" of the curb / sidewalk height. Placeagriculturally suitable top soil as needed. Thefinish grade of parking area "planter fingers" shallhave a crown with a 2-3% slope down to the curb /sidewalk.HDPE PLASTIC 2X4 EDGING1CITY STANDARD DETAILSExcept where illustrated on this sheet, see the following CityStandard Irrigation Details.·Tree Planting and Staking Standard 8220·Shrub Planting Standard 841091"=20'PLANTING PLAN1955LSP001SARJLS/SARSARSARA.1 C1"122.01"28.441"37.721"5.0641"58.341"622.0DIDI DI DI DI SYMBOL MANUFACTURER/MODEL/DESCRIPTIONQTY Rain Bird RWS-B-C-P-SOCK46Root Watering System with 4.0" diameter x36.0" long with locking grate, semi-rigid meshtube. Check Valve, Purple Grate, and SandSock. Rain Bird bubbler option as indicated:1404 1.0 gpm, SYMBOL MANUFACTURER/MODEL/DESCRIPTIONQTY Pipe Transition Point above grade9Pipe transition point from PVC lateral to driptubing with riser to above grade installation. Rain Bird OPERIND5Drip System Operation Indicator, stem rises 6"for clear visibility when drip system is chargedto a minimum of 20psi. Includes 16" of 1/4"distribution tubing with connection fittingpre-installed. Area to Receive Dripline Hunter PLD-R-10-18 (18) (2)3,775 s.f.In-Line Pressure Compensating LandscapeDripline with Built-In Check Valve. 1.0GPHemitters at 18.0" O.C. Dripline laterals spacedat 18.0" apart, with emitters offset fortriangular pattern. UV Resistant. PurpleTubing for Reclaimed Water Use. SYMBOL MANUFACTURER/MODEL/DESCRIPTIONQTY Hunter ICV-G-R61", 1-1/2", 2", and 3" Plastic Electric RemoteControl Valves, Globe Configuration, withNPT Threaded Inlet/Outlet, forCommercial/Municipal Use. Reclaimed WaterID, Purple Handle. Hunter HQ-33DLRC-R2Quick coupler valve, purple locking rubbercover for reclaimed water use, red brass andstainless steel, with 3/4" NPT inlet, 2-piecebody. Griswold Isolator BV3Brass DWS Valve with Ball Valve. Sizes 1/2"through 2-1/2", same size as irrigation line.100 mesh stainless steel strainer and packinggland ball valve are ideal for dirty waterapplications.DIIRRIGATION SCHEDULE Hunter ICV-G-BSP 1"11", Plastic Electric Master Valve, GlobeConfiguration, with BSP Threaded Inlet/Outlet,for Commercial/Municipal Use. ReclaimedWater Handle. 1" Pressure Reducing Valve1 Pressure limited to 60.13 PSIIn-line Pressure Reducing Valve located invalve box. Set pressure as needed foroptimum valve performance CALSENSE: CS3000 Controller1CITY REQUIRED -CS3-8-S1/CS3-LR/LR-STUBBY/FM1B/This is an 8 station CS3000 controller, factorymounted in a stainless steel top-mountenclosure assembly, local radio for centralcommunications, appropriate antenna, andCalsense flow sensor. CALSENSE FM1B1Flow Sensor compatible with CALSENSEcontroller Rain Bird RBY-100-MPTX11" Inline RBY Filter with 200 Mesh Screen Water Meter 1"1POC - Reclaimed Water Meter, per Civil Plans Irrigation Lateral Line: PVC Schedule 401,607 l.f.PVC Schedule 40 irrigation pipe color code foruse with reclaimed water. Only lateraltransition pipe sizes 1" and above areindicated on the plan, with all others being3/4" in size. Irrigation Mainline: PVC Schedule 40442.3 l.f.1 1/4" Dia. Main line. Color coded for use withReclaimed Water Pipe Sleeve: PVC Schedule 40211.0 l.f.Typical pipe sleeve for irrigation pipe. Pipesleeve size shall allow for irrigation piping andtheir related couplings to easily slide throughsleeving material. Extend sleeves 18 inchesbeyond edges of paving or construction.CNUMBERMODELSIZETYPEPSIPSI @ POCGPMPRECIP 1Hunter ICV-G-R1"Bubbler37.8150.1122.0030.64 in/h 2Hunter ICV-G-R1"Area for Dripline56.0960.888.440.75 in/h 3Hunter ICV-G-R1"Area for Dripline53.5858.067.720.75 in/h 4Hunter ICV-G-R1"Area for Dripline53.2557.205.060.75 in/h 5Hunter ICV-G-R1"Area for Dripline25.9931.828.340.74 in/h 6Hunter ICV-G-R1"Bubbler40.0458.8822.0030.64 in/hVALVE SCHEDULEGenerated:2016-08-10 10:31P.O.C. NUMBER: 01Water Source Information:POC - Reclaimed Water Meter, per Civil PlansFLOW AVAILABLEWater Meter Size:1"Flow Available:37.50 gpmPRESSURE AVAILABLEStatic Pressure at POC:70.00 psiElevation Change:5.00 ftService Line Size:1 1/2"Length of Service Line:20.00 ftPressure Available:67.00 psiDESIGN ANALYSISMaximum Station Flow:22.00 gpmFlow Available at POC:37.50 gpmResidual Flow Available:15.50 gpmCritical Station:2 Design Pressure:50.00 psi Elevation Loss:0.43 psi Friction Loss:2.56 psi Fittings Loss:0.26 psi Loss through Valve:2.84 psiPressure Req. at Critical Station:56.10 psiLoss for Fittings:0.09 psiLoss for Main Line:0.88 psiLoss for POC to Valve Elevation:0.43 psiLoss for Backflow:0.00 psiLoss for Master Valve:2.84 psiLoss for Water Meter:0.54 psiCritical Station Pressure at POC:60.88 psiPressure Available:67.00 psiResidual Pressure Available:6.12 psiCRITICAL ANALYSISO:\PRJ\1955\1955LSP001.dwg 5/22/2017 8:41:02 AMCALLE JOAQUIN PARK-N-RIDE LOTCITY SPECIFICATION NO.5/25/17DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.13DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSLO CITY BDR LAST UPDATED 8-11-15 91288NORTH0SCALE: feet2040601" = 20'GENERAL IRRIGATION NOTES1.Irrigation system designed for a static pressure of70-psi. adjust pressure reducer at POC accordingly.Drip system designed for maximum 50-psi.2.The irrigation system is designed to comply with theState Model Water Efficient Landscape Ordinance.3.Irrigation system shall not be installed untillandscape grading is complete, and approved byCity.4.Irrigation system shall be installed in accordancewith all local codes and regulations. All materialsshall be in new perfect condition and commercialgrade. Provide manufacture cut sheets for approval.Deviations from the specified materials must be "orequal" or approved by the Landscape Architect orOwner.5.Verify the location of all planting areas prior to startof project. Notify Landscape Architect of anydiscrepancies prior to trenching.6.Plan is diagrammatic and not intended to showexact locations of piping and valves. Locate inplanter areas as closely as possible to related curbsand edges of paving.7.House remote control valves in rectangular plasticvalve box with bolt down cover. Place valve twelve(12) inches from adjacent sidewalk, curb or headerboard. Set top of valve box even with finish grade.8.House quick coupling valves in ten (10) inch roundplastic valve box with bolt down lid. Set top of valvebox even with finish grade. Stake quick couplingvalves with stabilizer consisting of 3/4" angle iron,twelve (12) inches long connected to quick couplingvalve with "U" bolt. Place one (1) inch drain rockunder quick coupling valve and box to a twelve (12)inch depth according to detail.9.Adjust flow controls on all remote control valves andpressure reducer to correct operating pressure at allbubbler / emitters. Drip system designed for 50-psimaximum.10.All main line, gate valves, RCV's and QCV's shall beinstalled in planting areas, whether shown there ornot.11.IRRIGATION SLEEVE: 4" DIA Sch. 40 PVC sleevesto be used under all pavement and concrete walks.Irrigation sleeves to extend 12 - 18" minimumbeyond back of curb/walk. Coordinate sleeveinstallation with roadway / sidewalk pavingimprovements.IRRIGATION SCHEDULE NOTES1.The contractor is responsible for the finalirrigation schedule showing a minimum offour-seasons.2.The watering schedule shall include runtime and frequency of irrigation for eachstation with irrigation occurring betweensunset and sunrise. Should an individualstation require more than one cycle within a24-hour period, the minimum time betweencycles shall be 1-hour.3.Contractor shall provide a copy of theschedule, irrigation as-builts and any otherappurtenances necessary for the use andmaintenance of the system per thespecifications to the Owner.RECYCLED WATER USED1.Irrigation water source is RECLAIMEDNON-POTABLE. See Special ProvisionsSection 20-2.01.2.Irrigation water is from Recycled waterprovided by the City of San Luis Obispo. Theinstallation of the irrigation system shalladhere to the standards / requirements ofthe City.3.Refer to project special provisions forinformation regarding: valve box lidmarkings, pipe color and markings, tags andstickers,and required signs.Tags and signsshall be in both English and Spanish.SURFACEMOUNT ONLY!SEE DETAILS101"=20'IRRIGATION PLAN1955LSP001SARJLS/SARSARSARA.1 O:\PRJ\1955\1955LSP001.dwg 5/22/2017 8:41:58 AMCALLE JOAQUIN PARK-N-RIDE LOTCITY SPECIFICATION NO.5/25/17DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.13DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSLO CITY BDR LAST UPDATED 8-11-15 91288TYPICAL DRIPLINE LAYOUT REQUIREMENTSCENTER FEED EXAMPLELATERAL FLOW PER 100 FT (GPM)END FEED EXAMPLEGRID PRECIPITATION RATES (IN/HR)MAXIMUM FLOW PER ZONEMAXIMUM LATERAL LENGTH (FEET)SINGLE LINE FEED EXAMPLE2IN-LINE EMITTER ON GRADE - DRIP3IRRIGATION PIPE AND CONTROL WIRE TRENCHING1CITY STANDARD DETAILSExcept where illustrated on this sheet, see the following City StandardIrrigation Details.·Irrigation Controller Standard 8520; Attach Recycled Water WarningTag per Standard 8810·Master Valve and Flow Sensor Standard 8550·Thrust Blocking Standard 8610·Remote Control Valve Standard 8620·Quick Coupler Valve Standard 8630·Isolation Valve Standard 8640; Attach Recycled Water Warning Tagper Standard 8810REMOTE CONTROL VALVE NOTE:1.Pressure reducer and wye strainer located at point of connection.Typical Drip Valve kit not required for drip control valve. Seeirrigation schedule.DRIP SYSTEM OPERATION INDICATOR11AS SHOWNIRRIGATION DETAILS1955LSP001SARJLS/SARSARSARWATER USE CALCULATIONSA.1