Loading...
HomeMy WebLinkAboutItem #2 - ARCH-1014-2017 (1041 Mill) ARCHITECTURAL REVIEW COMMISSION AGENDA REPORT SUBJECT: Continued review of a new, two-story, 3,411-square foot office building, including a requested height exception of 26 inches above the maximum allowed height of 25 feet, a 10% shared parking reduction and provision of five additional bicycle spaces onsite, four compact spaces and reduced bay width to accommodate onsite parking, and the removal of one palm tree, with a Class 32 Categorical Exemption (Infill Development) from environmental review. PROJECT ADDRESS: 1041 Mill Street BY: Shawna Scott, Associate Planner Phone Number: (805) 781-7176 e-mail: sscott@slocity.org FILE NUMBER: ARCH-1014-2017 FROM: Doug Davidson, Deputy Director dd RECOMMENDATION: Adopt the Draft Resolution (Attachment 1) which approves the project, based on findings, and subject to conditions. SITE DATA Applicant Kevin Teixeira  Teixeira Capital Partners II, LLC  Representative Larry Borello, Architect  Submittal Date August 30, 2017  Complete Date December 7, 2017  Zoning O (Office)  General Plan Office  Site Area 0.16 acre (7,000 square feet)  Environmental  Status  Categorical Exemption from  environmental review (Class 32  In‐Fill Development Projects)  SUMMARY The applicant is proposing to construct a new approximately 27-foot tall, 3,411-square foot, two-story office building, nine onsite parking spaces, 7 bicycle spaces, and associated fencing and landscaping. To accommodate onsite parking and comply with standard yard setbacks, the applicant has requested a 10% shared parking reduction, provision of five additional bicycle spaces in lieu of one parking space, and incorporation of four compact spaces and reduced bay width. The applicant’s request includes the removal of one palm tree from the project site. The project site is zoned Office and is located within the Downtown Planning Area (outside the Downtown Core). Meeting Date: March 5, 2018 Item Number: 2 ARC2-1 ARCH-1014-2017 (1041 Mill) Page 2 The project was previously reviewed by the Architectural Review Commission (ARC) on January 29, 2018 (refer to Attachment 5, ARC Direction and Draft Minutes). At that time, the ARC provided directional items (refer to Section 3.0 Project Analysis) and continued design review of the project to a date uncertain. 1.0 COMMISSION’S PURVIEW The ARC’s role is to review the project in terms of its consistency with the Community Design Guidelines (CDG) and applicable City policies and standards. 2.0 PROJECT INFORMATION 2.1 Site Information/Setting 2.2 Project Description The proposed revised project consists of a new two-story office building with:  Ten offices totaling 2,176 square feet, one 185-square foot conference room, 182-square foot lobby, and two restrooms;  Nine onsite parking spaces (including four compact spaces) and 7 bicycle spaces;  Shared parking reduction (10%);  Removal of one palm tree from the site (approved by the City Arborist);  Six-foot tall fence, 30-inch tall garden fence, front courtyard, and landscaping;  Enclosed trash/recycling bins in the rear of the property;  Request for a height exception of 26 inches above the maximum allowed height of 25 feet. The revised project design includes various materials including horizontal cement board siding (green and gray), a composition shingle roof (black), and aluminum windows (white trim), gutters, and downspouts (refer to Attachment 3, Revised Project Plans). The fascia, rakes, doors, trellis, and fence would be painted white. Refer to Figures 1 and 2 on the following page for a visual comparison of the previous and revised front elevation. Zoning O (Office) Site Size 0.16 acre (7,000 square feet) Present Use & Development Vacant  Topography Nearly level Access Mill Street and Palm‐Mill Alley  Surrounding Use/Zoning North: Offices, residences / O South:  Offices / O  East: Offices/ O  West: Offices / O ARC2-2 ARCH-1014-2017 (1041 Mill) Page 3 Figure 1. Previous Front Elevation Figure 2. Revised Front Elevation 2.3 Revised Project Statistics Notes: 1. Applicant’s project plans dated February 8, 2018 2. Zoning Regulations dated March 2015 3. Includes 10% shared parking reduction and provision of 5 additional bicycle spaces 3.0 PROJECT ANALYSIS The discussion below focuses on the applicant’s response to the ARC directional items. Please refer to the previous ARC Agenda Report, dated January 29, 2018 for additional project analysis. This report is available online: < http://opengov.slocity.org/weblink/1/doc/70521/Page1.aspx > and the previously-reviewed plans are provided in Attachment 4. 3.1 Response to Directional Items: The applicant submitted revised project plans and responses to directional items identified by the ARC at the January 29, 2018 meeting (refer to Attachment 3, Applicant Response and Revised Plans). The area of the structure is the same; however, previously ten offices were proposed and the current proposal includes nine offices. Overall, the revised design responds to ARC direction by eliminating the front parking spaces, providing a more balanced structure, and incorporating more Craftsman-style elements. Each directional item is discussed below. Item Proposed 1 Standard 2 Setback Front Yard 15 feet 15 feet Other Yard First Story Second Story 5 feet 6.5 feet; 8 feet 5 feet 6.5 feet; 8 feet Max. Height 25 feet, 26 inches 25 feet Max. Building Coverage 25% 60% Parking Spaces Vehicle 9 3 11 Bicycle (short-term) 1 1 Bicycle (long-term) 6 1 ARC2-3 ARCH-1014-2017 (1041 Mill) Page 4 Directional Items #1 and #2: The requested street yard exception for the two unenclosed parking spaces was not supported by the ARC. Submit plans showing the removal of these two spaces from the site plan. The request may include a 10% shared parking reduction and provision of five bicycle spaces (short and long-term), in compliance with Zoning Regulations Section 17.16.060.G: Bicycle and Motorcycle Spaces.1 Response: The applicant submitted revised plans that eliminate the two front parking spaces, which is consistent with the direction provided by the ARC. The applicant is requesting a 10% shared parking reduction to reduce parking by one space.2 The revised project includes a request for five additional onsite bicycle spaces to reduce vehicle parking by an additional space, resulting in a total reduction of two spaces. This provision in combination with the 10% shared parking reduction would result in nine onsite parking spaces and would not require the removal of any street parking spaces. In the area that was previously designated for the two front parking spaces, the applicant proposes a larger front courtyard area including a pony wall, additional landscaping, and additional bicycle parking. Directional Item #3: The requested tree removal was not supported by the ARC. Submit plans showing, in the following order of preference: 1) retention of the tree in place; 2) relocation of the tree on-site; or 3) relocation of the tree off-site. Response: Removal of the palm tree remains a component of the applicant’s request for the ARC’s consideration. The applicant’s stated reasons for this request include: provision of required parking and the correct placement of the ADA parking stall; making the project financially viable; the possibility of falling palm fronds causing property damage and/or personal injury and the liability it creates even if the palm tree is maintained; and, the City Arborist approved removal of the tree as conditioned for new plantings and associated maintenance (refer to Attachment 3, Applicant Response to ARC Comments on January 29, 2018). The ARC should discuss if additional provisions to retain or relocate the tree should be provided by the applicant, or if removal of the palm tree is acceptable based on the revised project design, additional information regarding American Disabilities Act (ADA) parking requirements (see Directional Item #4, below), and provision of new trees, as conditioned. Directional Item #4: Research if the van accessible ADA space can provide the protective striping on the driver (left) side of the space. Response: Regarding the ADA space, planning staff consulted with the City Building Division and concluded that the Code requires the following: “11B-502.3.4 Location. Access aisles shall not overlap the vehicular way. Access aisles shall be permitted to be placed on either side of the 1 Projects which provide more bicycle and/or motorcycle spaces than required may reduce the required car spaces at the rate of one car space for each five bicycle spaces, up to a 10% reduction, subject to the approval of the Community Development Director. 2 Zoning Regulations Section 17.16.060.B Parking Space Requirements, Shared parking reduction. ARC2-4 ARCH-1014-2017 (1041 Mill) Page 5 parking space except for van parking spaces which shall have access aisles located on the passenger side of the parking spaces”3. Directional Item #5: The ARC noted that the building appears to “max out” the project site, and the ARC requested a more compatible and transitional design. Provide more balance and proportion pursuant to Community Design Guidelines Section 2.2.A. Suggestions included modifying the top of plate elevations, lowering the eaves, steepening the roof pitch, providing window trim, for example. Response: The applicant’s revised plans include additional elements reflecting a traditional Craftsman design including: larger front windows on the ground floor; white windows and trim (previously black); white corner building trim (previously grey); and painted white trellis (previously wood color). The revised plans also show additional outlookers and kickers along the roofline and extended overhangs. To provide more balance to the rear 7-foot overhang, the design now includes four posts and a green pony wall. This feature meets the applicant’s desire to provide shade and cover for occupants entering the building. Refer to Attachment 3, Sheet A3.0, which show the building elevations. To provide more vertical balance to the structure, the applicant responded to ARC direction by lowering both the first and second floor plate heights to approximately nine feet (refer to Attachment 3, Sheet A3.1) and increased the roof pitch from 2:12 to 3:12 (refer to Attachment 3, Sheet A1.3). As a result, the applicant is now requesting a 26-inch height exception (previously 20 inches). Directional Item #6: Additional direction included adding green color to the rear of the structure. Response: The revised plans incorporate green accents on the rear (alley) elevation, in response to this directional item (refer to Attachment 3, Sheet A3.0). 4.0 ENVIRONMENTAL REVIEW The project is categorically exempt under Class 32, In-Fill Development Projects; Section 15332 of the State California Environmental Quality Act (CEQA) Guidelines, because the project is consistent with General Plan policies for the land use designation and is consistent with the applicable zoning designation and regulations. The project site occurs on a property of no more than five acres substantially surrounded by urban uses that has no value as habitat for endangered, rare or threatened species as the site is located on a developed property and is served by required utilities and public services. The project has been reviewed by the City Public Works Department, Transportation Division, and no significant traffic impacts were identified, based on the size and location of the project. 3 2016 California Access Compliance Advisory Reference Manual ARC2-5 ARCH-1014-2017 (1041 Mill) Page 6 5.0 OTHER DEPARTMENT COMMENTS The requirements of the other City departments are reflected in the Conditions of Approval. 6.0 ALTERNATIVE RECOMMENDATIONS 6.1. Deny the project based on findings of inconsistency with the Community Design Guidelines. This alternative is not recommended, because the project is consistent with the General Plan and Community Design Guidelines, and further architectural review could be accommodated in the review process. 6.2 Continue the project to a date uncertain, with specific directional items provided. 7.0 ATTACHMENTS 1. Draft Resolution 2. Vicinity Map 3. Applicant Response and Revised Project Plans 4. Previous Plans (reviewed by ARC on January 29, 2018) 5. ARC Direction and Draft ARC Minutes, January 29, 2018 Included in Commission member portfolio: Revised project plans Available at ARC hearing: Color and materials board Available online: ARC Agenda Report, January 29, 2018 < http://opengov.slocity.org/weblink/1/doc/70521/Page1.aspx > ARC2-6 R ______ RESOLUTION NO. ARC-XXXX-18 A RESOLUTION OF THE ARCHITECTURAL REVIEW COMMISSION OF THE CITY OF SAN LUIS OBISPO, CALIFORNIA, APPROVING THE DESIGN OF A NEW TWO-STORY OFFICE BUILDING THAT INCLUDES ONSITE PARKING, INCLUDING A 10% SHARED PARKING REDUCTION, PROVISION OF FIVE ADDITIONAL BICYCLE SPACES AND REDUCTION OF ONE ADDITIONAL VEHICLE SPACE, REMOVAL OF ONE TREE, REMOVAL OF ONE METERED STREET PARKING SPACE, AND REQUESTED HEIGHT EXCEPTION, WITH A CATEGORICAL EXEMPTION FROM ENVIRONMENTAL REVIEW, AS REPRESENTED IN THE STAFF REPORT AND ATTACHMENTS DATED MARCH 5, 2018 (1041 MILL STREET, ARCH-1014-2017) WHEREAS, the Architectural Review Commission of the City of San Luis Obispo conducted a public hearing in the Council Hearing Room of City Hall, 990 Palm Street, San Luis Obispo, California, on January 29, 2018, pursuant to a proceeding instituted under ARCH-1014- 2017, Teixeira Capital Partners II, LLC, applicant, and the Commission provided directional items to the applicant and staff, and continued the hearing to a date uncertain; and, WHEREAS, the Architectural Review Commission of the City of San Luis Obispo conducted a public hearing in the Council Hearing Room of City Hall, 990 Palm Street, San Luis Obispo, California, on March 5, 2018, pursuant to a proceeding instituted under ARCH-1014- 2017, Teixeira Capital Partners II, LLC, applicant; and WHEREAS, notices of said public hearing were made at the time and in the manner required by law; and WHEREAS, the Architectural Review Commission of the City of San Luis Obispo has duly considered all evidence, including the testimony of the applicant, interested parties, and evaluation and recommendations by staff, presented at said hearing; and NOW, THEREFORE, BE IT RESOLVED by the Architectural Review Commission of the City of San Luis Obispo as follows: SECTION 1. Findings. by the Architectural Review Commission hereby grants approval to application ARCH-1014-2017, based on the following findings: a) The project will not be detrimental to the health, safety, and welfare of persons living or working at the site or in the vicinity because the project will be compatible with site constraints and the scale and character of the site and the surrounding neighborhood. b) As conditioned, the project is consistent with the City’s General Plan applicable to development in an Office area. The project is consistent with Land Use Element Policy 3.5.1.B because offices are proposed within the Office land use designation, ATTACHMENT 1 ARC2-7 Resolution No. _____ (2018 Series) Page 2 and based on the size and location of the project, and proximity to transit and bicycle routes, would not generate substantial traffic affecting residential neighborhoods. The project is consistent with Land Use Element Policy 4.2.2 because it is a new office building that would not require the conversion of an existing residence, and would not contribute to the loss of residential units in the Downtown area. The project is consistent with Land Use Element Policy 4.14 because it provides adequate on-site, off-street parking. c) As conditioned, the project is consistent with the City’s Community Design Guidelines applicable to commercial office and downtown development because the proposed project incorporates materials and forms that are similar to the surrounding neighborhood, demonstrates four-sided architecture, includes vertical and horizontal articulation, and provides a complementary color scheme. d) The exceptions granted to allow the 10% shared parking reduction and incorporation of compact vehicle parking spaces would not constitute a grant of special privilege inconsistent with the driveway or parking limitations upon other properties in the vicinity, and would not adversely affect the health, safety, or general welfare of persons working or residing in the vicinity, as subject parcel is approximately 7,000 square feet in size, the project site is proximate to existing bicycle lanes and public transit facilities, adequate parking would be provided onsite, including vehicle parking spaces and additional bicycle spaces to be shared by the office tenants, and vehicle parking would be accommodated in the rear of the property and accessed via the Palm-Mill Alley, similar to adjacent office uses. The exception is reasonably necessary for the applicant’s full enjoyment of uses permitted on the property, including development of an office building in the Office zone. e) The project is categorically exempt from the provisions of the California Environmental Quality Act (CEQA) because it consists of the redevelopment of the project site consistent with policies and standards applicable to development within an Office area, on a site less than five acres in size, with no value as habitat for endangered, rare, or threatened species, as described in State CEQA Guidelines Section 15332 (Infill Development). The site is within City limits and is served by City utilities and public services. Based on the location, size, and area and quantity of commercial and residential components of the development, approval of the project will not result in any significant effects related to traffic, noise, air quality, or water quality. SECTION 2. Action. The Architectural Review Commission hereby grants approval to application ARCH-1014-2017, with incorporation of the following conditions: Please note the project conditions of approval do not include mandatory code requirements. Code compliance will be verified during the plan check process, which may include additional requirements applicable to your project. ATTACHMENT 1 ARC2-8 Resolution No. _____ (2018 Series) Page 3 Planning 1. Final project design and construction drawings submitted for a building permit shall be in substantial compliance with the project plans approved by the ARC. A separate, full-size sheet shall be included in working drawings submitted for a building permit that lists all conditions and code requirements of project approval listed as sheet number 2. Reference shall be made in the margin of listed items as to where in plans requirements are addressed. Any change to approved design, colors, materials, landscaping, or other conditions of approval must be approved by the Director or Architectural Review Commission, as deemed appropriate. 2. The locations of all lighting fixtures shall be clearly called out on building elevations included as part of working drawings. The lighting schedule for the building shall include a graphic representation of the proposed lighting fixtures and cut-sheets shall be separately submitted for the project file of the proposed lighting fixtures. The selected fixture(s) shall be shielded to ensure that light is directed downward consistent with Section 17.23.050 of the Zoning Regulations. Details of all exterior light fixtures, including any service area lights, need to be included as part of plans. A note shall be included on plans that “Lenses of exterior wall-mounted lights may be modified or shielding devices added after installation if the Community Development Director determines that they emit excessive glare.” 3. Plans submitted for a building permit shall include window details indicating the type of materials for the window frames and mullions, their dimensions, and colors. Plans shall include the materials and dimensions of all lintels, sills, surrounds recesses and other related window features. 4. Plans submitted for a building permit shall call out the colors and materials of all proposed building surfaces and other improvements on elevation drawings. 5. An encroachment permit will be required from the Public Works Department for any work or construction staging in the public right-of-way. 6. Mechanical and electrical equipment shall be located internally to the building or adequately screened at the ground level. With submittal of working drawings, the applicant shall include sectional views of the building, which clearly show screening of mechanical equipment to the satisfaction of the Community Development Director. A line-of-sight diagram may be needed to confirm that proposed screening will be adequate. 7. The location of any required backflow preventer and double-check assembly shall be shown on plans submitted for a building permit, including the landscaping plan. Construction plans shall also include a scaled diagram of the equipment proposed. Any backflow preventer and double check assembly shall be screened using a combination of paint color, landscaping, and if deemed appropriate by the Community Development Director, a low wall. The size and configuration of such equipment shall be subject to review and approval by the Utilities and Community Development Directors. ATTACHMENT 1 ARC2-9 Resolution No. _____ (2018 Series) Page 4 8. All fencing, visible from the public right-of-way, shall be maintained so that fencing materials and support are structurally sound, with no missing material. All fencing, including the proposed trellis, shall comply with requirements identified in Zoning Regulations Section 17.16.050. 9. The storage area for trash and recycling cans shall be screened from the public right-of-way. The subject property shall be maintained in a clean and orderly manner at all times; free of excessive leaves, branches, and other landscape material. The applicant shall be responsible for the clean-up of any landscape material in the public right-of-way. 10. Plans submitted for a building permit shall include a final landscaping plan, including irrigation details. The legend for the landscaping plan shall include the sizes and species of all groundcovers, shrubs, and trees with corresponding symbols for each plant material showing their specific locations on plans. Any proposed landscape lighting shall be shown on plans submitted for a building permit and plans shall clearly indicate lighting to utilize a narrow cone of light (no brighter than approximately 15 watts) for the purpose of confining the light to the object of interest. 11. Proposed signage for the project shall be submitted for the review and approval of the Community Development Director. The submittal shall include information on the size, location, colors, materials, and types and illumination of signage proposed for the building and the overall site. Project signs shall be designed to be compatible with the architecture of proposed buildings and to complement the site’s setting. Signs shall utilize more innovative and attractive solutions such as raised, backlit metal letters, halo lighting or external lighting rather than plastic cabinet signs or channel letters with internal illumination. The Director may approve signage if s/he finds that the proposal conforms to the sign regulations and is in keeping with the design characteristics of the building. The Director may refer signage to the ARC if it seems excessive or out of character with the building. 12. Plans submitted for a building permit shall show a minimum of one short-term bicycle rack at the front of the building and six long-term bicycle spaces. Approved short-term bicycle rack designs include the inverted "U" or "Peak Racks". "Ribbon" type racks are not approved for use in the City. 13. To satisfy the City’s Inclusionary Housing Requirements, applicant shall pay Affordable Housing In-Lieu Fees equal to 5% of building valuation. 14. Development of the driveway and parking areas shall comply with the Parking and Driveway Standards for dimension, maneuverability, slopes, drainage, and materials. Alternate paving materials such as permeable pavers are recommended for water quantity and/or quality control purposes and in accordance with Land Use Element Policies 6.6.5 (Runoff Reduction and Groundwater Recharge) and 6.6.6 (Development Requirements). Alternate paving material shall be approved to the satisfaction of the Community Development and Public Works Directors. 15. The applicant shall defend, indemnify and hold harmless the City and/or its agents, officers ATTACHMENT 1 ARC2-10 Resolution No. _____ (2018 Series) Page 5 and employees from any claim, action or proceeding against the City and/or its agents, officers or employees to attack, set aside, void or annul, the approval by the City of this project, and all actions relating thereto, including but not limited to environmental review (“Indemnified Claims”). The City shall promptly notify the applicant of any Indemnified Claim upon being presented with the Indemnified Claim and the City shall fully cooperate in the defense against an Indemnified Claim. Engineering 16. The existing 10’ x 10’ parcel deeded from Santa Maria Gas and Power Company and noted as Parcel 2 in the title report shall be merged with the noted Parcel 1 prior to building permit issuance. 17. The building plan submittal shall include a complete site utility plan. All existing and proposed utilities along with utility company meters shall be shown. Existing underground and overhead services shall be shown along with any proposed alterations or upgrades. Services to the new structures shall be underground. All work in the public right-of-way shall be shown or noted. 18. The building plan submittal shall include a complete grading, drainage and topo plan. The plan shall consider historic offsite drainage tributary to this property that may need to be conveyed along with the improved on-site drainage. This development will alter and/or increase the storm water runoff from this site. The improved drainage shall be directed to the street or alley and not across adjoining property lines unless the drainage is conveyed within recorded easements or existing waterways. 19. The building plan submittal shall show compliance with the Post Construction Stormwater Requirements as promulgated by the Regional Water Quality Control Board for newly developed sites. Include a complete Post Construction Stormwater Control Plan Template as available on the City’s Website. 20. The City Arborist supports the removal of the palm tree with one new compensatory on-site tree planting. The building plan submittal shall show two new street trees. One street tree shall be planted within the existing parkway per city engineering standards. Tree species and planting requirements shall be per city engineering standards, and shall incorporate the use of structural soils. Utilities 21. A new sewer lateral shall be constructed with the proposed project, and any sewer lateral that crosses one proposed parcel for the benefit of another shall provide evidence that a private utility easement appropriate for those facilities has been recorded prior to final Building Permit. The proposed gravity sewer system shall use HDPE pipe, or an approved equal, that meets or exceeds the performance needed to eliminate groundwater infiltration and root intrusion. ATTACHMENT 1 ARC2-11 Resolution No. _____ (2018 Series) Page 6 22. The project’s commercial meters shall be adequately sized to serve the project, to the satisfaction of the Utilities Director. 23. The proposed utility infrastructure shall comply with the latest engineering design standards in effect during the time a building permit is obtained, and shall have reasonable alignments and clearances needed for maintenance. 24. Trash enclosure(s) shall conform the access requirements by the San Luis Garbage Company, and refuse bins shall be sized to provide a reasonable level of service. 25. Driveways and access routes to all trash and recycling receptacles shall be designed to accommodate the size and weight of garbage trucks. 26. Potable city water shall not be used for major construction activities, such as grading and dust control, as required under Prohibited Water Uses; Chapter 17.07.070.C of the City’s Municipal Code. Upon motion of _______________________, seconded by _______________________, and on the following roll call vote: AYES: NOES: ABSENT: The foregoing resolution was adopted this _____ day of _____________________ 2016. ____________________________________ Doug Davidson, Secretary Architectural Review Commission ATTACHMENT 1 ARC2-12 O O O O-H PFPF-H PFO PF-HMILLPALMO S O S VICINITY MAP ARCH-1014-2017 1041 Mill Street ¯ ATTACHMENT 2 ARC2-13 ATTACHMENT 3 ARC2-14 ATTACHMENT 3 ARC2-15 A1011SIM00' - 0 3/8"0' - 0 3/8"1i1i?11DETAILSECTIONGRID DESIGNATIONDIMENSION (FOS)DIMENSION (CENTERLINE)CONTROL POINTDOOR IDENTIFICATIONWINDOW IDENTIFICATIONREFERENCE NOTEINTERIOR ELEVATIONREVISIONDETAIL NUMBERSHEET WHERE DETAIL OCCURSDIRECTION OF CUTSECTION NUMBER (OR LETTER)SHEET ON WHICH SECTION OCCURSGRID NUMBER (NUMBER IN ONE DIRECTION, LETTERS IN THE OTHER DIRECTION)GRID LINEDIMENSION TO FACE OF STUD, MASONRY OR CONCRETE (UNLESS NOTED OTHERWISE)DIMENSION TO CENTERLINEELEVATION, WORK POINT, CONTROL POINT, OR DATUM POINTDOOR NUMBER, REFER TO DOOR SCHEDULEWINDOW SYMBOL, REFER TO WINDOW SCHEDULEREFERENCE NOTE, SEE THAT SHEETDIRECTION OF VIEW REFERENCEDREVISION NUMBER, CLOUD AROUND REVISION IS OPTIONALINTERIOR ELEVATION IDENTIFICATION(CLOCKWISE NUMBERING ORDER)ORA1011SIMPROJECT LOCATIONPEACHMILLPALMMONTEREYHIGUERASANTA ROSAOSOS STMORROTORO101CIVIL AND STRUCTURALENGINEERING:ASHLEY & VANCE ENGINEERING, INC.1413 MONTEREY STREET SAN LUIS OBISPO, CA 93401PHONE: (805)545-0010SOILS REPORT:GSI SOILS, INC.524 E. CHAPEL ST.SANTA MARIA, CA 93454PHONE: (805)349-5493SURVEY:LANDSCAPE ARCHITECT:PLEINAIRE DESIGN GROUP2601 SKYWAY DRIVE, SUITE A-1SANTA MARIA, CA 93455PHONE: (805)349-9695JON McKELLAR910 E. STOWELL RD.SANTA MARIA, CA 93454PHONE: (805)680-1895 JOB NO. CLIENT PROJECT SHEET TITLE REVISIONSSHEET NO. DATEThe use of these plans and specifications shall berestricted to the original site for which they wereprepared and publications therof is expressly limited tosuch use. Re-use, reproduction, or publication by anymethod, in whole or in part is prohibited. Title to theplans and specifications remains with and shall not beused without the expressed written permission ofLawrence Manuel Borello.ARCHITECTURE - PLANNING -GRAPHICSLARRYBBOORREELLLLOOARCHITECTLos Osos, CaliforniaPhone: (805) 458-2759E-mail:lmborello@yahoo.comA0.008FEB18TITLE SHEETMILL STREETOFFICE BUILDING1041 MILL STREETSAN LUIS OBISPO, CA93401TEIXEIRA CAPITALPARTNERS II LLC195 S. BROADWAY, SU.#204ORCUTT, CAPhone: (805) 698-3520 JOB NO. CLIENT PROJECT SHEET TITLE REVISIONSSHEET NO. DATEThe use of these plans and specifications shall berestricted to the original site for which they wereprepared and publications therof is expressly limited tosuch use. Re-use, reproduction, or publication by anymethod, in whole or in part is prohibited. Title to theplans and specifications remains with and shall not beused without the expressed written permission ofLawrence Manuel Borello.ARCHITECTURE - PLANNING -GRAPHICSLARRYBORELLOARCHITECTLos Osos, CaliforniaPhone: (805) 458-2759E-mail:lmborello@yahoo.comA0.008FEB18TITLE SHEETMILL STREETOFFICE BUILDING1041 MILL STREETSAN LUIS OBISPO, CA93401TEIXEIRA CAPITALPARTNERS II LLC195 S. BROADWAY, SU.#204ORCUTT, CAPhone: (805) 698-3520MILL STREET OFFICE BUILDING1041 MILL STREET, SAN LUIS OBISPO, CA 93401 APN: 002-323-023SECT SECTIONSF SQUARE FOOT(FEET)SFA SUBMIT FORAPPROVALSH SINGLE HUNGSHLVS SHELVESSHT SHEETSHTG SHEATHINGSIM SIMILARSPECS SPECIFICATIONSSQ SQUARESS STAINLESS STEELSS SERVICE SINKSTD STANDARDSTL STEELSTR STRINGERSTRUCTSTRUCTURALSUSP SUSPENDEDTTREADT&G TONGUE & GROOVETB TOWEL BARTC TOP OF CURBTD TOP OF DRAINTEMP TEMPEREDTEXTR TEXTURETF TOP OF FOOTINGTHK THICKTHRESHTHRESHOLDTOJ TOP OF JOISTTOL TOP OF LEDGERTP TOP OF PAVINGTP TOP OF PARAPETTP TOP OF PLATETS TOE SPACETS STEEL TUBETV TELEVISIONTW TOP OF WALLTYP TYPICALUNO UNLESS NOTEDOTHERWISEVB VINYL BASEVCT VINYL COMPOSITIONTILEVENT VENTILATIONVERT VERTICALVOL VOLUMNW WESTW WASHING MACHINEW/ WITHWC WATERCLOSETWD WOODWF WIDE-FLANGEWH WATER HEATERWIN WINDOWWMM WELDED WIRE MESHWP WATERPROOFINGWP WEATHERPROOFINGWRB WATER RESISTIVEBARRIERWS WATER SOFTENERWT WEIGHTYD YARDMACH MACHINEMAX MAXIMUMMC MEDICINE CABINETMECH MECHANICALMFR MANUFACTURE(R)MIN MINIMUMMISC MISCELLANEOUSMR MIRRORMTL METAL(N) NEWN NORTHN/A NOT APPLICABLENIC NOT IN CONTRACTNO NUMBER (#)NTS NOT TO SCALEO OVENO/C ON CENTERO/H OVERHANGO/H OVERHEADOBSC OBSCUREOJ OPEN JOISTOPNG OPENINGOPP OPPOSITEOVFL OVER FLOWdPENNYP LAM PLASTIC LAMINATEPERF PERFORATEDPERIM PERIMETERPL PROPERTY LINEPLAS PLASTICPLYWD PLYWOODPR PAIRPROC PORCELAINPROJ PROJECTIONPROP PROPERTYPSI POUNDS PERSQUARE INCHPTDF PRESSURE TREATEDDOUGLAS FIRPTHF PRESSURE TREATEDHEMLOCK FIRQT QUARRY TILERRISERRRADIUSR REFERENCERAFT RAFTERRB RUBBER BASERD ROOF DRAINRECPRECEPTACLEREF REFERIGERATORREF REFRIGERATORREINF REINFORCINGREQ'D REQUIREDRM ROOMRR ROOF RAFTERRWD REDWOODRWL RAIN WATER LEADERS SOUTHS&P SHELF & POLESAF SELF ADHERINGFLASHINGSB SPASH BLOCKSC SOLID CORESC SLIDINGSCH SCHEDULEEXP EXPANSIONEXT EXTERIORFAU FORCED AIR UNITFD FLOOR DRAINFDN FOUNDATIONFF FINISH FLOORFG FINISH GRADEFG FIBERGLASSFG FIXED GLASSFIN FINISHFIX FIXTUREFJ FLOOR JOISTFL FLOW LINEFLASH FLASHINGFLR FLOORFLUOR FLUORESCENTFOS FACE OF STUDFOW FACE OF WALLFR FRAMEFS FINISH SLABFT FOOT (FEET)FTG FOOTINGGAGAUGEGALV GALVANIZEDGB GRAB BARGEN GENERALGI GALVANIZED IRONGL GLASSGPM GALLONS PERMINUTEGR GRADEGR GRAB RAILGYP GYPSUMGYP BD GYPSUM BOARDHB HOSE BIBBHC HOLLOW COREHD HOLD-DOWNHDR HEADERHDW HARDWAREHDWD HARDWOODHM HOLLOW METALHORIZ HORIZONTALHR HOURHR HAND RAILHT HEIGHTHTR HEATERIN INCHINCL INCLUDE(ING)INFO INFORMATIONINSUL INSULATIONINT INTERIORISA INTERNATIONALSYMBOL OFACCESSIBILITYJCT JUNCTIONJST JOISTJT JOINTLOW TRANSMISSIONLAM LAMINATE(D)LAV LAVATORYLB POUNDS (#)LN LINELNTL LINTELLT LIGHT@ATAB ANCHOR BOLTABV ABOVEAC ASPHALT CONCRETEADJ ADJUSTABLEAFF ABOVE FINISHFLOORALT ALTERNATEALUM ALUMINUMAPPR APPROXIMATEAPPRD APPROVEDARCH ARCHITECTURALBD BOARDBEV BEVELEDBLK(G) BLOCK(ING)BM BEAMBOT BOTTOMBRNG BEARINGBS BACK OF SIDEWALKBUR BUILT-UP ROOFCAB CABINETCB CATCH BASINCBC CALIFORNIABUILDING CODECFA CONDITIONEDFLOOR AREACI CAST IRONCJ CEILING JOISTCJ CONTROL JOINTCLG CEILINGCLRCLEARCOL COMPOSITIONCOMP COMPOSITIONCON CONCRETECONN CONNECTIONCONT CONTINUOUSCONTR CONTRACTORCT CERAMIC TILECTRSK COUNTERSINKCY CUBIC YARDDDRYERDET DETAILDF DOUGLAS FIRDF DRINKING FOUNTAINDH DOUBLE HUNGDIA DIAMETERDIAG DIAGONALDIM DIMENSIONDN DOWNDR DOORDRN DRAINDS DOWNSPOUTDT DRAPERY TRACTDW DISHWASHERDWG DRAWING(E) EXISTINGE EASTEA EACHEG EXISTING GRADEEJ EXPANSION JOINTELEC ELECTRIC(AL)ELEV ELEVATIONEP ELECTRICAL PANELEQ EQUALEQUIP EQUIPMENTEW EACH WAYEXC EXCAVATEPROJECT DATACODE SUMMARYCONCEPTUAL AERIAL IMAGEABBREVIATIONSDRAWING INDEXDESCRIPTIONSHEET NUMBERNORTHVICINITY MAPSYMBOLSA0.0TITLE SHEETA1.0EXISTING SITE PLANA1.1ROOF PLAN OVER EXISTING CONTOUR MAPA1.2SITE PLANA1.3STREET ELEVATION AND SITE SECTIONSC-1.1GRADING AND DRAINAGE PLANC-2.1UTILITY PLANCLP.01CONCEPTUAL LANDSCAPE PLANCLP.02PLANT IMAGERYA2.1FLOOR PLANSA3.0EXTERIOR VIEWSA3.1EXTERIOR ELEVATIONSCONSULTANTSPROJECT SITEATTACHMENT 3ARC2-16 X XXXXXXXXXXXXXXXXX XXXXXXXXXX36° 14' 24"140.01'SE36° 13' 39"140.01'NW53°38'49"50.00'SW53°38'12"49.97'NE10' - 0" 30' - 0"M I L L S T R E E TP A L M M I L L A L L E YSHEDWOOD FENCEWOOD FENCE36 PALMEDGE OF PAVEMENTCATVPG&ETELE0.16 acres1041 MILL STREETCENTERLINE OF R.O.W.CENTERLINE OF R.O.W.1045 MILL STREET103 MILL STREET(APPR. FOOTPRINT)(APPR. FOOTPRINT)(E) PALM TREE(E) DRIVEWAY APRON @ 1023 MILL STREET(E) DRIVEWAY APRON @ 857 SANTA ROSA STREET1023 MILL STREET1051 MILL STREET857 SANTA ROSA STREET JOB NO. CLIENT PROJECT SHEET TITLE REVISIONSSHEET NO. DATEThe use of these plans and specifications shall berestricted to the original site for which they wereprepared and publications therof is expressly limited tosuch use. Re-use, reproduction, or publication by anymethod, in whole or in part is prohibited. Title to theplans and specifications remains with and shall not beused without the expressed written permission ofLawrence Manuel Borello.ARCHITECTURE - PLANNING -GRAPHICSLARRYBORELLOARCHITECTLos Osos, CaliforniaPhone: (805) 458-2759E-mail:lmborello@yahoo.comA1.008NOV17EXISTING SITEPLANMILL STREETOFFICE BUILDING1041 MILL STREETSAN LUIS OBISPO, CA93401TEIXEIRA CAPITALPARTNERS II LLC195 S. BROADWAY, SU.#204ORCUTT, CAPhone: (805) 698-3520TRUENORTHSCALE: 1" = 10'-0"EXISTING SITE PLANATTACHMENT 3ARC2-17 252.00'253.00'254.00'255.00'256.00'257.00'250.00'251.00'252.00'253.00'254.00'255.00'255.00'255.00'M I L L S T R E E T(R.O.W.)20' - 0"SETBACK15' - 0"PROPOSED BUILDINGFF. 255.89'SETBACK5' - 0"SETBACK5' - 0"265.72' LOWER ROOF265.74' LOWER ROOF278.86' UPPER ROOF273.59' LOWER ROOF279.08' ROOF265.61' LOWER ROOF281.66'6' - 6" 8' - 0"36° 14' 24"140.01'SE53°38'12"49.97'NE53°38'49"50.00'SW36° 13' 39"140.01'NWP A L M M I L L A L L E Y253.00' LOW POINT NATURAL GRADE256.00' HIGH POINT NATURAL GRADETOTAL BUILDING HEIGHT (RIDGE HT.)LOWEST NATURAL GRADE POINT UNDER BUILDING:253.00'HIGHEST NATURAL GRADE POINT UNDER BUILDING:256.00'AVERAGE NATURAL GRADE:(253.00' 256.00') / 2 .NOTE SEE SITE PLAN ON THIS SHEET FOR ELEVATION POINTSTOTAL BUILDING HEIGHT ALLOWED:. (.)TOTAL BUILDING HEIGHT PROPOSED:1.11 ( . 1) JOB NO. CLIENT PROJECT SHEET TITLE REVISIONSSHEET NO. DATEThe use of these plans and specifications shall berestricted to the original site for which they wereprepared and publications therof is expressly limited tosuch use. Re-use, reproduction, or publication by anymethod, in whole or in part is prohibited. Title to theplans and specifications remains with and shall not beused without the expressed written permission ofLawrence Manuel Borello.ARCHITECTURE - PLANNING -GRAPHICSLARRYBORELLOARCHITECTLos Osos, CaliforniaPhone: (805) 458-2759E-mail:lmborello@yahoo.comA1.108NOV17ROOF PLAN OVEREXISTINGCONTOURSMILL STREETOFFICE BUILDING1041 MILL STREETSAN LUIS OBISPO, CA93401TEIXEIRA CAPITALPARTNERS II LLC195 S. BROADWAY, SU.#204ORCUTT, CAPhone: (805) 698-3520GENERAL NOTESLEGENDSSCALE: 1" = 10'-0"ROOF PLAN OVER EXISTING CONTOURSTRUENORTHBUILDING HEIGHT CALCULATIONATTACHMENT 3ARC2-18 M I L L S T R E E TSHEDCATVPG&ETELE(R.O.W.)20' - 0"4' - 0"SETBACK 15' - 0"3' - 0"LOBBYOFFICEOFFICEOFFICEOFFICEOFFICER.R.OFFICECOURTYARDPROPOSED BUILDINGFF. 255.89'1A1.31A1.3SETBACK5' - 0"SETBACK5' - 0"9' - 0"9' - 0"9' - 0" ±4' - 4"2' - 6" 15' - 4" 9' - 0"16' - 0"8' - 0"8' - 0"9' - 0" 2' - 6" 42' - 2"1ADACOMPACTCOMPACTCOMPACTCOMPACT1045 MILL STREET103 MILL STREET(APPR. FOOTPRINT)(APPR. FOOTPRINT)2A1.32A1.3P A L M M I L L A L L E Y7' - 2"8"2' - 6" ±1' - 10"18' - 0" 24' - 2"48' - 10"36° 14' 24"140.01'SE36° 13' 39"140.01'NW53°38'12"49.97'NE53°38'49"50.00'SW1234556189101111(E) DRIVEWAY APRON @ 1023 MILL STREET(E) DRIVEWAY APRON @ 857 SANTA ROSA STREET1023 MILL STREET1051 MILL STREET857 SANTA ROSA STREET1' - 2"8' - 10"17' - 0"121212121352A1.31414151553A1.253A1.254A1.254A1.28' - 0" SETBACK8' - 0" SETBACK416118191' - 7 1/2"20212222CONCRETELANDSCAPING PAVERS.6' - 02 X 6 CONT RDWD1 X 8 CEDAR BOARDS (HORIZONTAL)2 X 4 TOP & BOT4 X 4 PTDF POST A@ 6'-0 O.C.CONC WALLSIMPSON LCB44 POST BASE22' - 6.6' - 02 X 6 CONT RDWD1 X 8 CEDAR BOARDS (HORIZONTAL)2 X 4 TOP & BOT4 X 4 PTDF POST A@ 6'-0 O.C.12 CONC FOOTINGCOURSE GRAVEL JOB NO. CLIENT PROJECT SHEET TITLE REVISIONSSHEET NO. DATEThe use of these plans and specifications shall berestricted to the original site for which they wereprepared and publications therof is expressly limited tosuch use. Re-use, reproduction, or publication by anymethod, in whole or in part is prohibited. Title to theplans and specifications remains with and shall not beused without the expressed written permission ofLawrence Manuel Borello.ARCHITECTURE - PLANNING -GRAPHICSLARRYBORELLOARCHITECTLos Osos, CaliforniaPhone: (805) 458-2759E-mail:lmborello@yahoo.comA1.208NOV17SITE PLANMILL STREETOFFICE BUILDING1041 MILL STREETSAN LUIS OBISPO, CA93401TEIXEIRA CAPITALPARTNERS II LLC195 S. BROADWAY, SU.#204ORCUTT, CAPhone: (805) 698-3520LEGENDSTRUENORTHSCALE: 1" = 10'-0"SITE PLANSITE PLAN LEGENDKEYNOTES1 ACCESSIBLE PATH - OF - TRAVEL2 (N) 30 HIGH GARDEN WALL (FINISH TO MATCH BUILDING SIDING)3 (N) WOOD TRELLIS POSTS4 SECOND FLOOR ABOVE (DASHED LINE)5 A/C CONDENSERS FOR MINI SPLIT SYSTEM HEAT PUMPS (TYP. OF 13). CONDENSERSTO BE SET AWAY FROM PROPERTY LINE AS FAR AS POSSIBLE (3'-0 APPR.).SCREENING OF UNITS IS PROVIDED BY FENCING ALONG THE PROPERTY LINE AND ATTHE FRONT AND BACK OF THE BUILDING.6 6 RAMP UP PER CIVIL DRAWINGS6 STEP UP PER CIVIL DRAWINGS8 EXISTING PALM TREE TO BE REMOVED (PHOENIX CANARIENSIS CANARY ISLAND DATEPALM)9 (N) TRASH ENCLOSER PER CITY STD. #8.04-D-210 EDGE OF EXISTING ALLEY PAVEMENT11 WOOD FENCE12 3'-0 WIDE WOOD GATE - MATCH FENCE13 (N) LANDSCAPE / SITE LIGHTING14 START FENCE15 STOP FENCE AT PLANTER16 IRRIGATION BACKFLOW PREVENTION VALVE, PER LANDSCAPE PLAN1 FIRE DEPT BACKFLOW PREVENTION DEVICE WITH FIRE DEPT. CONNECTION, PERUTILITY PLAN18 WATER METER, PER UTILITY PLAN19 FIRE SPRINKLER RISER (2 1/2 )20 (1) BIKE SPACE (SHORT TERM STORAGE)21 (2) BIKE SPACES IN CLOSET UNDER STAIR (LONG TERM STORAGE)22 (2) BIKE SPACES IN LOCKER, TYP OF 2 (LONG TERM STORAGE)WOOD FENCE @ CONC WALL - TYP54WOOD FENCE - TYP53ATTACHMENT 3ARC2-19