Loading...
HomeMy WebLinkAboutR-10933 making findings on energy savings and determining other matters in connection with energy service agreementsRESOLUTION NO. 10933 (2018 SERIES) A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SAN LUIS OBISPO, CALIFORNIA, MAKING FINDINGS ON ENERGY SAVINGS AND DETERMINING OTHER MATTERS IN CONNECTION WITH ENERGY SERVICE AGREEMENTS WHEREAS, it is the policy of the State of California and the intent of the State Legislature to promote all feasible means of energy conservation and all feasible uses of alternative energy supply sources; and WHEREAS, the City of San Luis Obispo ("City") desires to reduce energy costs at its facilities; and WHEREAS, the City proposes to enter into power purchase agreements ("Power Purchase Agreements") and related contract documents with ForeFront Power ("ForeFront") for facilities at the City's real property sites, pursuant to which ForeFront will design, construct, and install solar photovoltaic and energy storage facilities and arrange with the local utility for interconnection of the facilities, which will generate and store energy for the sites on which such facilities are located; and WHEREAS, ForeFront has provided the City with analysis showing the financial and other benefits of entering into the Power Purchase Agreements, which analysis is attached hereto as Exhibit A and made part hereof by this reference; and WHEREAS, Exhibit A includes data showing that the anticipated cost to the City for the electrical energy provided by the solar photovoltaic and energy storage facilities will be less than the anticipated cost to the City of electrical energy that would have been consumed by the City in the absence of such measures; and WHEREAS, ForeFront was the selected vendor for School Project for Utility Rate Reduction's ("SPURR") Renewable Energy Aggregated Procurement ("REAP") Program, a competitive statewide solar and energy storage request for proposals ("RFP") process, and the City adopts the REAP Program's competitive process as its own; and WHEREAS, the City proposes to enter into the Power Purchase Agreements and related contract documents, each in substantially the form presented at this meeting, subject to such changes, insertions or omissions as the City Manager and City Attorney reasonably deems necessary following the Council's adoption of this Resolution; and WHEREAS, pursuant to Government Code section 4217.12, this Council held a public hearing, public notice of which was given two weeks in advance, to receive public comment. R 10933 Resolution No. 10933 (2018 Series) that: Page 2 NOW, THEREFORE, BE IT RESOLVED by the Council of the City of San Luis Obispo SECTION 1. The terms of the Power Purchase Agreements and related agreements are in the best interests of the City. SECTION 2. In accordance with Government Code section 4217.12, and based on data provided by Exhibit A, the Council finds that the anticipated cost to the City for electrical energy provided by the Power Purchase Agreements will be less than the anticipated cost to the City of electrical energy that would have been consumed by the City in the absence of the Power Purchase Agreements. SECTION 3. The Council hereby approves the Power Purchase Agreements in accordance with Government Code section 4217.12. SECTION 4. The City Manager and City Attorney are hereby authorized and directed to negotiate any further changes, insertions and omissions to the Power Purchase Agreements as they reasonably deems necessary, and thereafter to execute and deliver the Power Purchase Agreements following the Council's adoption of this Resolution. The City Manager is further authorized and directed to execute and deliver any and all papers, instruments, opinions, certificates, affidavits and other documents and to do or cause to be done any and all other acts and things necessary or proper for carrying out this Resolution and said Agreements. SECTION 5. Environmental Review. The City Council hereby determines that the execution of a power purchase agreement with Forefront Power are statutorily and categorically exempt from environmental review on the basis that the projects are: installation of solar energy systems on existing roofs or at existing parking lots (Public Resources Code § 21080.35; new construction or conversion of small structures (CEQA Guidelines § 15303); minor alterations to land (CEQA Guidelines § 15304); projects which consist of the construction or placement of minor accessory structures to existing facilities (CEQA Guidelines § 15311); and activities which can be seen with seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment (CEQA Guidelines § 15061(b)(3). . R 10933 Resolution No. 10933 (2018 Series) Page 3 SECTION 7. City staff are hereby authorized to file and process a Notice of CEQA Exemption for the Project in accordance with CEQA and the State CEQA Guidelines, and the findings set forth in this resolution. Upon motion of Council Member Pease, seconded by Vice Mayor Christianson, and on the following roll call vote: AYES: Council Members Gomez, Pease and Rivoire, Vice Mayor Christianson and Mayor Harmon NOES: None ABSENT: None The foregoing resolution was adopted this 4 1 day of September 2018. ATTEST: M1 Teresa Purrington City Clerk APPROVED AS TO FORM: y. -Christine D. City Attorney IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official seal of the City of San Luis Obispo, California, this ���� day of , 2D l $ •w Teresa Purrington City Clerk R 10933 Project Cashflows Financial Assumptions Parameter Value Project SLO City Res 1 Site Year 1 PPA Rate ($/kWh)$0.0950 Scenario No PG&E Upgrade Expenses PPA Rate Escalator (%/yr)0.0% Year 1 Savings $19,971 Utility Rate Escalator (%/yr)3.0% Cumulative Savings $1,414,690 Solar Degradation Rate (%)0.50% Payback Period Immediate Year Production (kWh) Average Weighted Bill Credit Value ($/kWh) Bill Credits ($)PPA Rate Solar Payment ($)Total Savings for District ($)Cumulative Savings 1 1,482,451 $0.1085 160,804 $0.0950 140,833 19,971 19,971 2 1,475,039 $0.1117 164,800 $0.0950 140,129 24,671 44,642 3 1,467,663 $0.1151 168,895 $0.0950 139,428 29,467 74,110 4 1,460,325 $0.1185 173,092 $0.0950 138,731 34,361 108,471 5 1,453,024 $0.1221 177,394 $0.0950 138,037 39,356 147,827 6 1,445,758 $0.1257 181,802 $0.0950 137,347 44,455 192,282 7 1,438,530 $0.1295 186,320 $0.0950 136,660 49,659 241,941 8 1,431,337 $0.1334 190,950 $0.0950 135,977 54,973 296,914 9 1,424,180 $0.1374 195,695 $0.0950 135,297 60,398 357,311 10 1,417,059 $0.1415 200,558 $0.0950 134,621 65,937 423,249 11 1,409,974 $0.1458 205,542 $0.0950 133,948 71,594 494,843 12 1,402,924 $0.1502 210,649 $0.0950 133,278 77,372 572,214 13 1,395,910 $0.1547 215,884 $0.0950 132,611 83,273 655,487 14 1,388,930 $0.1593 221,249 $0.0950 131,948 89,300 744,787 15 1,381,985 $0.1641 226,747 $0.0950 131,289 95,458 840,245 16 1,375,075 $0.1690 232,381 $0.0950 130,632 101,749 941,994 17 1,368,200 $0.1741 238,156 $0.0950 129,979 108,177 1,050,171 18 1,361,359 $0.1793 244,074 $0.0950 129,329 114,745 1,164,916 19 1,354,552 $0.1847 250,139 $0.0950 128,682 121,457 1,286,373 20 1,347,780 $0.1902 256,355 $0.0950 128,039 128,316 1,414,690 Total 28,282,056 $0.0000 $4,101,485 $0.0950 $2,686,795 $1,414,690 $1,414,690 44,455 65,937 128,316 0 50000 100000 150000 200000 250000 300000 Res 1 RES-BCT Site Annual Savings Average Weighted Bill Credit Value ($/kWh)Solar Payment ($)Total Savings for District ($) 192,282 423,249 1,414,690 0 500,000 1,000,000 1,500,000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Res 1 RES-BCT Site Cumulative Savings Cumulative Savings Resolution No. 10933 (2018 Series) EXHIBIT A Page 4 R 10933 Project Cashflows Financial Assumptions Parameter Value Project SLO City Res 1 Site Year 1 PPA Rate ($/kWh)$0.1150 Scenario With PG&E Upgrade Expenses PPA Rate Escalator (%/yr)0.0% Year 1 Savings -$9,678 Utility Rate Escalator (%/yr)3.0% Cumulative Savings $849,049 Solar Degradation Rate (%)0.50% Payback Period Immediate Year Production (kWh) Average Weighted Bill Credit Value ($/kWh) Bill Credits ($)PPA Rate Solar Payment ($)Total Savings for District ($)Cumulative Savings 1 1,482,451 $0.1085 160,804 $0.1150 170,482 -9,678 -9,678 2 1,475,039 $0.1117 164,800 $0.1150 169,629 -4,830 -14,507 3 1,467,663 $0.1151 168,895 $0.1150 168,781 114 -14,394 4 1,460,325 $0.1185 173,092 $0.1150 167,937 5,155 -9,239 5 1,453,024 $0.1221 177,394 $0.1150 167,098 10,296 1,057 6 1,445,758 $0.1257 181,802 $0.1150 166,262 15,540 16,597 7 1,438,530 $0.1295 186,320 $0.1150 165,431 20,889 37,485 8 1,431,337 $0.1334 190,950 $0.1150 164,604 26,346 63,831 9 1,424,180 $0.1374 195,695 $0.1150 163,781 31,914 95,745 10 1,417,059 $0.1415 200,558 $0.1150 162,962 37,596 133,341 11 1,409,974 $0.1458 205,542 $0.1150 162,147 43,395 176,736 12 1,402,924 $0.1502 210,649 $0.1150 161,336 49,313 226,049 13 1,395,910 $0.1547 215,884 $0.1150 160,530 55,354 281,403 14 1,388,930 $0.1593 221,249 $0.1150 159,727 61,522 342,925 15 1,381,985 $0.1641 226,747 $0.1150 158,928 67,818 410,743 16 1,375,075 $0.1690 232,381 $0.1150 158,134 74,248 484,991 17 1,368,200 $0.1741 238,156 $0.1150 157,343 80,813 565,804 18 1,361,359 $0.1793 244,074 $0.1150 156,556 87,518 653,322 19 1,354,552 $0.1847 250,139 $0.1150 155,774 94,366 747,688 20 1,347,780 $0.1902 256,355 $0.1150 154,995 101,361 849,049 Total 28,282,056 $0.0000 $4,101,485 $0.1150 $3,252,436 $849,049 $849,049 15,540 37,596 101,361 -50000 0 50000 100000 150000 200000 250000 300000 Res 1 RES-BCT Site Annual Savings Average Weighted Bill Credit Value ($/kWh)Solar Payment ($)Total Savings for District ($) 16,597 133,341 849,049 -200,000 0 200,000 400,000 600,000 800,000 1,000,000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Res 1 RES-BCT Site Cumulative Savings Cumulative Savings Resolution No. 10933 (2018 Series) EXHIBIT A Page 5 R 10933 Project Cashflows Financial Assumptions Parameter Value Project SLO City Res 1 Site Year 1 PPA Rate ($/kWh)$0.1050 Scenario $200K PG&E Upgrade Expenses PPA Rate Escalator (%/yr)0.0% Year 1 Savings $5,147 Utility Rate Escalator (%/yr)3.0% Cumulative Savings $1,131,869 Solar Degradation Rate (%)0.50% Payback Period Immediate Year Production (kWh) Average Weighted Bill Credit Value ($/kWh) Bill Credits ($)PPA Rate Solar Payment ($)Total Savings for District ($)Cumulative Savings 1 1,482,451 $0.1085 160,804 $0.1050 155,657 5,147 5,147 2 1,475,039 $0.1117 164,800 $0.1050 154,879 9,921 15,067 3 1,467,663 $0.1151 168,895 $0.1050 154,105 14,791 29,858 4 1,460,325 $0.1185 173,092 $0.1050 153,334 19,758 49,616 5 1,453,024 $0.1221 177,394 $0.1050 152,567 24,826 74,442 6 1,445,758 $0.1257 181,802 $0.1050 151,805 29,997 104,439 7 1,438,530 $0.1295 186,320 $0.1050 151,046 35,274 139,713 8 1,431,337 $0.1334 190,950 $0.1050 150,290 40,659 180,373 9 1,424,180 $0.1374 195,695 $0.1050 149,539 46,156 226,528 10 1,417,059 $0.1415 200,558 $0.1050 148,791 51,767 278,295 11 1,409,974 $0.1458 205,542 $0.1050 148,047 57,494 335,789 12 1,402,924 $0.1502 210,649 $0.1050 147,307 63,342 399,131 13 1,395,910 $0.1547 215,884 $0.1050 146,571 69,313 468,445 14 1,388,930 $0.1593 221,249 $0.1050 145,838 75,411 543,856 15 1,381,985 $0.1641 226,747 $0.1050 145,108 81,638 625,494 16 1,375,075 $0.1690 232,381 $0.1050 144,383 87,998 713,493 17 1,368,200 $0.1741 238,156 $0.1050 143,661 94,495 807,988 18 1,361,359 $0.1793 244,074 $0.1050 142,943 101,131 909,119 19 1,354,552 $0.1847 250,139 $0.1050 142,228 107,911 1,017,031 20 1,347,780 $0.1902 256,355 $0.1050 141,517 114,839 1,131,869 Total 28,282,056 $0.0000 $4,101,485 $0.1050 $2,969,616 $1,131,869 $1,131,869 29,997 51,767 114,839 0 50000 100000 150000 200000 250000 300000 Res 1 RES-BCT Site Annual Savings Average Weighted Bill Credit Value ($/kWh)Solar Payment ($)Total Savings for District ($) 104,439 278,295 1,131,869 0 200,000 400,000 600,000 800,000 1,000,000 1,200,000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Res 1 RES-BCT Site Cumulative Savings Cumulative Savings Resolution No. 10933 (2018 Series) EXHIBIT A Page 6 R 10933 Project Cashflows: SLO Swim Center - Portfolio Pricing - Flat PPA Rate Scenario Current Solutions Solar + Storage Project Canopy Financial Assumptions Year 1 Savings $1,893 Parameter Value Cumulative Savings $324,550 PPA Rate Escalator (%/yr)0.0% Cumulative NPV Savings $224,242 Utility Energy Escalator (%/yr)2.7% Payback Period Immediate Utility Demand Escalator (%/yr)5.0% Solar System Size (KW)163 Discount Rate (%)3.0% Storage System Size (KW)0 Solar Degradation Rate (%)0.50% Year KWH Generated Historic Utility Bill (without solar) Total Electricity Costs (PPA + Utility)Net Savings Cumulative Savings Cumulative NPV Savings 1 260,963 60,650 58,757 1,893 1,893 1,893 2 259,658 62,787 59,622 3,165 5,058 4,966 3 258,360 65,007 60,536 4,471 9,529 9,180 4 257,068 67,313 61,503 5,810 15,339 14,497 5 255,783 69,709 62,524 7,185 22,524 20,881 6 254,504 72,198 63,602 8,597 31,120 28,296 7 253,231 74,786 64,739 10,047 41,167 36,710 8 251,965 77,474 65,937 11,537 52,705 46,091 9 250,705 80,269 67,200 13,070 65,774 56,409 10 249,452 83,175 68,529 14,645 80,420 67,633 11 248,205 86,196 69,929 16,266 96,686 79,737 12 246,964 89,337 71,402 17,935 114,621 92,693 13 245,729 92,603 72,951 19,652 134,273 106,477 14 244,500 96,001 74,579 21,422 155,695 121,064 15 243,278 99,535 76,291 23,244 178,939 136,431 16 242,061 103,212 78,089 25,123 204,062 152,557 17 240,851 107,037 79,977 27,060 231,123 169,420 18 239,647 111,018 81,959 29,059 260,181 187,001 19 238,448 115,161 84,040 31,120 291,301 205,281 20 237,256 119,473 86,224 33,248 324,550 224,242 Total 4,978,627 $1,732,941 $1,408,391 $324,550 $324,550 $224,242 Resolution No. 10933 (2018 Series) EXHIBIT A Page 7 R 10933