Loading...
HomeMy WebLinkAbout11-13-2018 Item 9 Request for Alternative Incentive to Provide for Affordable Housing - 3680 Broad Street AFFH-1902-2018 Meeting Date: 11/13/2018 FROM: Michael Codron, Community Development Director Prepared By: Rachel Cohen, Associate Planner SUBJECT: REQUEST FOR ALTERNATIVE INCENTIVE TO PROVIDE FOR AFFORDABLE HOUSING THAT INCLUDES A DENSITY BONUS INCREASE OF 43 PERCENT, WHERE 35 PERCENT IS NORMALLY ALLOWED, FOR 3680 BROAD STREET (CITY FILE NO. AFFH-1902-2018). RECOMMENDATION Adopt a Resolution (Attachment A) approving the alternative incentive to provide for affordable housing that include a density bonus increase of 43 percent, where 35 percent is normally allowed. DISCUSSION Applicant HASLO Representative Scott Smith Zoning Service Commercial with a special considerations overlay (C-S-S) General Plan Services Manufacturing Site Area 1.6 acres Environmental Status Categorically Exempt from environmental review under Section 15332, Class 32, In-fill Development Projects, of the CEQA Guidelines. In June 2018, HASLO, the applicant, requested a modification to a mixed-use affordable housing project located at 3680 Broad Street within the C-S-S zone. In April and May 2015, the Planning Commission (PC) and the Architectural Review Commission (ARC) reviewed and approved the mixed-use project. The approved project included a 4,400 square foot commercial building, two, three-story structures with 46 affordable one, two, and three-bedroom units, and a 29 percent density bonus. The applicant has requested to modify the 4,400 square foot commercial structure to include nine market rate dwelling units and 3,425 square feet of commercial space (ARCH-1638-2018). The Director determined that the modifications were minor and approved the proposed modifications to the plan (Attachment B, Project Plans and Attachment C, Director’s Approval Letter). The Packet Pg. 109 Item 9 additional nine units expand the original project density bonus request of 29 percent to 43 percent. The applicant is requesting an alternative incentive for a 43 percent density bonus, where 35 percent is normally allowed. If approved the project would be 84 percent affordable. Zoning Regulations Chapter 17.140 Affordable Housing Incentives states that when an applicant is requesting an alternative incentive for affordable housing, the incentives shall be reviewed by the City Council. In order to deny the requests, State law (Government Code Section 65915) requires specific findings based on substantial evidence of any of the following: • The incentive or concession does not result in identifiable and actual cost reductions for affordable housing costs; • The incentive would have specific adverse impact1 upon health, safety, or the physical environment on any real property that is listed in the California Register of Historical Resources; • The incentive would be contrary to state of federal law. This provision of the Zoning Regulations is proposed to be modified to provide the Planning Commission with the authority to approve affordable housing incentives, however, the new provision will not go into effect unless approved by the City Council on November 27, 2018. Background On April 8, 2015, the Planning Commission reviewed and approved a mixed-use affordable housing project located at 3680 Broad Street within the C-S-S zone. The project included a 4,400 square foot commercial building, two, three-story residential structures with 46 affordable one, two, and three-bedroom units and a 29 percent density bonus (USE-0809-2015). As a 100% affordable housing development, the applicant is entitled up to a 35 percent density bonus under State law. On May 4, 2015, the Architectural Review Commission (ARC) held a hearing to review the design and architecture of the proposed project as it relates to the surrounding neighborhood (ARCH-0810-2015). The ARC unanimously voted to approve the project. In March 2017, the applicant received their building permit for phase 1 of t he project, the construction of two, three-story residential structures. Final sign-off on the construction of the residential structures is anticipated by the beginning of November 2018. In June 2018, the applicant requested a modification to the 4,400 square foot commercial building to include nine market rate dwelling units and 3,425 square feet of commercial space. The additional nine units expand the original project density bonus request of 29 percent to 43 percent. On October 1, 2018, the Director of Community Development reviewed the proposed modification to the commercial building for consistency and compatibility with the previously approved use permit and architectural plans (ARCH-1638-2018). The Director determined that the modifications were minor and approved the proposed modifications to the plan (Attachment B, Project Plans and Attachment C, Director’s Approval Letter), subject to the approval of an 1 Gov. Code Section 65589.5 defines a “specific adverse impact” as a “specific, adverse impact” means a significant, quantifiable, direct, and unavoidable impact, based on objective, identified written public health or safety standards, policies, or conditions as they existed on the date the application was deemed complete. Packet Pg. 110 Item 9 increase in the density bonus to 43 percent. Project Analysis The City of San Luis Obispo has recognized housing as an important issue within the City. The City’s 2015-17 Financial Plan identifies affordable housing as a Major City Goal. The City’s Housing Element includes numerous policies and programs that support incentives, such as density bonuses, to provide housing for moderate, low, very low and extremely low-income households. 1. Affordable Housing Alternative Incentives Consistent with State law requirements, City Zoning Regulations Chapter 17.140.070 states that three incentives or concessions shall be granted for housing developments that include at least 30 percent for lower income households. The proposed project provides 84 percent of the units to be dedicated to low income (or lower) households. Chapter 17.140 of the Zoning Regulations (Affordable Housing Incentives) outlines various incentives for affordable housing projects that developers can request. Some of the alternative incentive examples called out in the Chapter includes granting of a density bonus in excess of State allowances or allowing a reduction in site development standards. Alternative Incentive Request: Granting a density bonus in excess of 35 percent The applicant is requesting an alternative incentive to allow a 43 percent density bonus, where 35 percent is normally allowed. The applicant would be providing a total of 55 units on the site. Table 1 provides a breakdown of the affordability of the units. Table 1: Unit Breakdown of Affordability Unit Type Number of Units % of Area Median Income (AMI) 1 Bedroom 10 60% 1 Bedroom 2 50% 2 Bedrooms 13 60% 2 Bedrooms 2 50% 3 Bedrooms 13 60% 3 Bedrooms 2 50% 2 Bedrooms 3 60% Studios 4 Market Rate 1 Bedroom 5 Market Rate Packet Pg. 111 Item 9 2. Housing Element The 2015 Housing Element (HE) outlines a series of goals and policies to encourage the development of housing production for all financial strata of the City's population. The City has outlined in HE Goal 2 that housing should be in-line with the Regional Housing Needs Allocation, for the 2014 - 2019 planning period (see Table 2). The HE further states that affordable housing units should be intermixed and not segregated by economic status and encourages housing development that meets a variety of special needs, including large families, single parents, disabled persons, the elderly, students, veterans, the homeless, or those seeking congregate care, group housing, single-room occupancy or co-housing accommodations, utilizing universal design (HE Policy 8.1). The Housing Element also states that preference for residential be given over commercial uses (Policy 11.1). In addition, the Housing Element further states: • That the City should continue to consider increasing residential densities above state density bonus allowances for projects that provide housing for low, very low and extremely low- income households (Policy 2.17); and • That the City should continue to incentivize affordable housing development with density bonuses, parking reductions and other development incentives, including City financial assistance (Program 6.19). Table 2: Housing Element Table 6: Remaining RHNA need based on dwelling units approved, under construction or built (January 1, 2014 to December 31, 2017) Income Category A B A-B New Construction Need (RHNA) Dwelling Units Approved, Under Construction or Built Remaining RHNA Need, Dwelling Units Very Low and Extremely-Low (<31-50% of AMI) 285 96 189 Low (51-80% of AMI) 179 27 152 Moderate (81-120% of AMI) 202 10 192 Above Moderate (>120% of AMI) 478 5901 -112 TOTAL RHNA UNITS 1,144 7231 421 1No credit allowed for the number of above moderate units built that exceed RHNA. 3. Major City Goal Housing was determined to be one of the most important, highest priority goals for the City to accomplish over 2015-17 financial year. The goal states: Implement the Housing Element, facilitating workforce, affordable, supportive and transitional housing options, including support for needed infrastructure within the City’s fair share. Packet Pg. 112 Item 9 ENVIRONMENTAL REVIEW The project is categorically exempt under Class 32, In-Fill Development Projects, Section 15332 of the CEQA Guidelines, because the project is consistent with General Plan policies for the land use designation and is consistent with the applicable zoning designation and regulations. The project site occurs on a property of no more than five acres substantially surrounded by urban uses that has no value as habitat for endangered, rare or threatened species as the site is located on an existing developed property and is served by required utilities and public services. FISCAL IMPACT When the General Plan was prepared, it was accompanied by a fiscal impact analysis, which found that overall the General Plan was fiscally balanced. Accordingly, since the proposed density bonus request is consistent with the General Plan, it has a neutral fiscal impact. ALTERNATIVES 1. Deny the request for a 43 percent density bonus and provide direction to staff to return with substantial evidence to support findings that the request is inconsistent with alternative or additional incentive regulations within the municipal code. This is not recommended because the request for incentives is consistent with State and City housing regulations. 2. Continue the project and provide direction to the applicant to revise the project for consistency with applicable City regulations. Attachments: a - Draft Resolution b - Project Plans c - Director's Approval Letter Packet Pg. 113 Item 9 RESOLUTION NO. _______ (2018 SERIES) A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SAN LUIS OBISPO, CALIFORNIA, APPROVING THE ALTERNATIVE INCENTIVES TO PROVIDE FOR AFFORDABLE HOUSING THAT INCLUDES A DENSITY BONUS OF 43 PERCENT, WHERE 35 PERCENT IS NORMALLY ALLOWED, AS REPRESENTED IN THE CITY COUNCIL AGENDA REPORT AND ATTACHMENTS DATED NOVEMBER 13, 2018. THE PROJECT IS CATEGORICALLY EXEMPT FROM ENVIRONMENTAL REVIEW (3680 BROAD STREET) (AFFH-1902-2018) WHEREAS, on September 24, 2018 the Housing Authority of San Luis Obispo (“HASLO”), submitted an application to request alternative incentives for affordable housing that include a forty-three (43) percent density bonus, where 35 percent is normally allowed; and WHEREAS, on April 8, 2015, the Planning Commission of the City of San Luis Obispo conducted a public hearing in the Council Chambers of City Hall, 990 Palm Street, San Luis Obispo, California, for the purpose of approving the use permit for a mixed-use project consisting of 4,400 square feet of commercial space and 46 affordable one, two, and three-bedroom units (USE-0809-2015); and WHEREAS, on May 4, 2015, the Architectural Review Commission of the City of San Luis Obispo conducted a public hearing in the Council Chambers of City Hall, 990 Palm Street, San Luis Obispo, California, for the purpose of approving the design of a mixed-use project consisting of 4,400 square feet of commercial space and 46 affordable one, two, and three-bedroom units (ARCH-0810-2015); and WHEREAS, on October 1, 2018, the Community Development Director of the City of San Luis Obispo reviewed a modification to the project to modify the commercial structure to include nine market rate units and 3,425 square feet of commercial space (ARCH-1638-2018); and WHEREAS, on November 13, 2018, the City Council of the City of San Luis Obispo conducted a public hearing in the Council Chambers of City Hall, 990 Palm Street, San Luis Obispo, California, pursuant to a proceeding instituted under AFFH-1902-2018; and WHEREAS, the City Council has duly considered all evidence, including the testimony of the applicant, interested parties, and the evaluation and recommendations by staff, presented at said hearing, and WHEREAS, notices of said public hearings were made at the time and in the manner required by law. NOW, THEREFORE, BE IT RESOLVED by the Council of the City of San Luis Obispo as follows: Packet Pg. 114 Item 9 Resolution No. _______________ (2018 Series) Page 2 R ______ SECTION 1. Findings. Based upon all the evidence, the City Council makes the following findings: 1. The project will not be detrimental to the health, safety, or welfare of those working or residing in the vicinity since the proposed project is consistent with the site’s zoning designation, the approved Planning Commission use permit (USE-0809-2015) and will be subject to conformance with all applicable building, fire, and safety codes. 2. The proposed project will provide quality affordable housing consistent with the intent of Chapter 17.90 of the Municipal Code. 3. The request for a density bonus is consistent with the intent of Housing Element policies 2.17, 8.1, 11.1 and program 6.19, and the alternative affordable housing incentives outlined in Section 17.90.060 of the City’s Zoning Regulations. SECTION 2. Environmental Review. The project is categorically exempt under Class 32, In-Fill Development Projects, Section 15332 of the CEQA Guidelines, because the project is consistent with General Plan policies for the land use designation and is consistent with the applicable zoning designation and regulations. The project site occurs on a property of no more than five acres substantially surrounded by urban uses that has no value as habitat for endangered, rare or threatened species as the site is located on an existing developed property and is served by required utilities and public services. SECTION 3. Action. The City Council does hereby grant final approval of the project including the request for alternative incentives to provide for affordable housing that includes a density bonus of 43 percent, where 35 percent is normally allowed (AFFH-1902-2018), subject to the following conditions: Planning Department 1. Final project design and construction drawings shall be in substantial compliance with the project plans approved by the Community Development Director and the City Council. A separate full-size sheet shall be included in working drawings submitted for a building permit that list all conditions, and code requirements of project approval as Sheet No. 2 (ARCH-1638-2018 & AFFH-1902-2018). Reference should be made in the margin of listed items as to where in plans requirements are addressed. 2. Prior to the issuance of building permits, the City and the project owners shall enter into an Affordable Housing Agreement in a form subject to the approval of the City Attorney and Community Development Director, to be recorded in the office of the county recorder. The agreement shall specify mechanisms or procedures to assure the continued affordability and availability the affordable units, to the satisfaction of the Community Development Director and City Attorney. The agreement shall also set forth those items required by Section 17.90.030(B) or any alternative incentives granted pursuant to Section 17.90.060. The agreement shall run with the land and shall be binding upon all heirs, successors or assigns of the project or property owner. Packet Pg. 115 Item 9 Resolution No. _______________ (2018 Series) Page 3 R ______ Indemnification 3. The Owner/Applicant shall defend, indemnify and hold harmless the City or its agents or officers and employees from any claim, action or proceeding against the City or its agents, officers or employees, to attack, set aside, void, or annul, in whole or in part, the City's approval of this project. Upon motion of _______________________, seconded by _______________________, and on the following roll call vote: AYES: NOES: ABSENT: The foregoing resolution was adopted this 13th day of November 2018. ____________________________________ Mayor Heidi Harmon ATTEST: ____________________________________ Teresa Purrington City Clerk APPROVED AS TO FORM: _____________________________________ J. Christine Dietrick City Attorney IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official seal of the City of San Luis Obispo, California, this ______ day of ______________, _________. ______________________________ Teresa Purrington City Clerk Packet Pg. 116 Item 9 IRON WORKS MIXED-USE THE IRON WORKS MIXED-USE PROJECT PROPOSES A NEW 8,243 SQUARE FOOT, 2-STORY MIXED-USE BUILDING COMPRISING 3,425 SQUARE FEET OF FUTURE COMMERCIAL SUITES, AND 9 ONE-BEDROOM AND STUDIO APARTMENTS. ENTITLEMENTS PACKAGE - ARC-MI Packet Pg. 117 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site T1.0 PROJECT DIRECTORY OWNER: HOUSING AUTHORITY OF SAN LUIS OBISPO CONTACT:MICHAEL BURKE 487 LEFF STREET PH:805.594.5330 SAN LUIS OBISPO, CA 93401 EMAIL: mburke@haslo.org ARCHITECT: TEN OVER STUDIO, INC.CONTACT:KARL LUNDEEN 539 MARSH STREET PH:805.541.1010 SAN LUIS OBISPO, CA 93401 EMAIL: karll@tenoverstudio.com SURVEY: ABOVE GRADE CONTACT:SCOTT STOKES 245 HIGUERA STREET PH:805.548.1172 SAN LUIS OBISPO, CA 93401 EMAIL: scott@abovegradeengineering.com CALIFORNIA CODE REFERENCES THIS PROJECT SHALL COMPLY WITH CURRENT APPLICABLE CODES & ORDINANCES 2016 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA HISTORICAL BUILDING CODE 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA EXISTING BUILDING CODE 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 2016 CALIFORNIA REFERENCE STANDARDS CODE CITY OF SAN LUIS OBISPO MUNICIPAL CODE: TITLE 15 BUILDINGS AND CONSTRUCTION CITY OF SAN LUIS OBISPO TITLE 17 ZONING REGULATIONS ADJACENT ZONES:NORTH EAST SOUTH WEST C-S-S C-S-S C-S-S C-S-S SETBACKS STREET: SIDE: REAR: SETBACK BASED ON ADJACENT ZONE: DRAINAGE EASEMENT STREET TREE, PUBLIC UTILITY STREET TREE DEDICATION LAND USE ANALYSIS 3680 BROAD STREET, SAN LUIS OBISPO, CA 053-231-047 C-S SPECIAL CONSIDERATION ZONE N/A RESIDENTIAL, COMMERCIAL 70,450 SF (1.6 ACRES) 75% (52,837 SF) 28% (19,586 SF) 47% (33,252 SF) 1.5 1.6 ACRES x 24 UNITS = 38.4 DU 43 FEET - USE-0809-2015 BLDGS ≤ 20 feet high = 10 feet BLDGS >20 feet high = 15 feet N/A N/A 0' 25' 50' EASEMENT: WETLAND PRESERVE AREA RESIDENTIAL SETBACK FROM PUBLIC RIGHT-OF-WAY PER SECTION 17.08.072(D) 10' 10' 20' ADDRESS: APN: ZONING: OVERLAY ZONES: DESIGN AREA GUIDELINES: FAR: ALLOWABLE DENSITY PER ZONE: (C-S - 24 DU / ACRE) HEIGHT LIMIT: ALLOWED USE (RELEVANT): LOT SIZE: MAX ALLOWABLE SITE COVERAGE: EXISTING SITE COVERAGE: REMAINING SITE COVERAGE: PROJECT DESCRIPTION THE IRON WORKS MIXED-USE PROJECT PROPOSES A NEW 8,243 SQUARE FOOT, 2-STORY MIXED-USE BUILDING. THE FIRST FLOOR COMPRISES 3,425 SQUARE FEET OF SHELL SPACE FOR FUTURE COMMERCIAL TENANTS, A ONE-BEDROOM APARTMENT, AND TWO TENANT ENTRIES FOR THE SECOND FLOOR. THE SECOND FLOOR INCLUDES 8 ADDITIONAL APARTMENTS – 4 STUDIOS AND 4 ONE-BEDROOM UNITS. ALL SITE IMPROVEMENTS, PARKING, AND TRASH ARE INCLUDED IN A SEPARATE, APPROVED PERMIT (PLBLDG-3371-2016). PROJECT INFO PROJECT INFO SITE PLAN UTILITY PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN UNIT PLANS A2.2 ELEVATIONS ELEVATIONS/MATERIALS MODEL IMAGES INDEX T1.0 T1.1 A1.0 A4.0 A2.0 A2.1 A3.0 A3.1 A1.1 Packet Pg. 118 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site T1.1 BUILDING ELEMENT RATING ALL 0 USE SYSTEM B & R-2 NFPA 13 USE LOAD FACTOR BUSINESS 100 GROSS RESIDENTIAL 200 GROSS USE DISTANCE BUSINESS 100' RESIDENTIAL 125' USE / USE B / R-2 B / B R-2 / R-2 USE MULTI-FAMILY DWELLINGS GENERAL RETAIL RESTAURANT MEDICAL SERVICE - CLINIC, LABORATORY, URGENT CARE TYPE VB PER 17.90.040: 1 PER STUDIO APARTMENT OR ONE BEDRROM APARMTENT, 2 FOR 2- OR 3- BEDROOM APARTMENTS. ALSO SEE PARKING REDUCTION PARAGRAPHS UNDER 17.16.060. ONE SPACE PER 60 SQ. FT. CUSTOMER USE AREA, INCLUDING WAITING SEATING, COUNTER SERVICE AREAS, AND DANCING AREAS, PLUS ONE SPACE PER 100 SQ. FT. FOOD PREPARATION, INCLUDING COUNTER SPACE, PANTRY STORAGE, AND DISHWASHING AREAS. WALLS, HALLS, RESTROOMS, AND DEAD STORAGE AREAS DO NOT COUNT AS EITHER CUSTOMER USE OR FOOD PREPARATION FLOOR AREA ONE PER 200 SQUARE FEET GROSS FLOOR AREA. ONE SPACE PER 300 SQUARE FEET GROSS FLOOR AREA PARKING FACTOR HOUR SEPARATION REQ’D 1-HOUR: FIRE BARRIERS PER 707, HORIZONTAL ASSEMBLIES PER 711 420.2 & 420.3: FIRE PARTITIONS PER 708 (1/2-HOUR PER 708.3 EXCEPTION 2), HORIZONTAL 711 (1/22-HOUR PER 711.2.4.3 EXCEPTION) FIRE SPRINKLER SYSTEMS: FIRE RATING REQUIREMENTS (PER CBC TABLE 601): B - 3, R-2 - 3 B - 60', R-2 - 60' B- 27,000, R-2 - 21,000 CONSTRUCTION TYPE: (PER CBC CHAPTER 5) ALLOWABLE STORIES: ALLOWABLE HEIGHT: ALLOWABLE AREA: OCCUPANCY USE ANALYSIS MIXED-USE: RESIDENTIAL (R-2) & BUSINESS (B) YES - PLANNING COMMISSION APPROVAL REQUIRED YES - USE-0809-2015 YES - ARCMI (PER DIRECTION FROM PLANNER) PROPOSED USE: ALLOWED USE IN ZONE: USE PERMIT REQ’D: ENTITLEMENTS REQ’D: OCCUPANCY LOAD FACTORS: (PER CBC TABLE 1004.1.2) LONGEST PATH OF TRAVEL BASED ON OCCUPANCY: OCCUPANCY SEPARATION REQUIREMENTS: PARKING REQUIREMENTS: FUTURE TENANT IMPROVEMENT PERMIT WILL BE SUBJECT AVAILABLE PARKING 173.75' UNIT TYPES # OF UNITS DENSITY UNITS (DU) STUDIOS: (.5 DU) 4 2 ONE BEDROOM UNITS: (0.66 DU) 5 3.33 TOTAL:9 UNITS 5.33 DU ROOM SF/PARKING FACTOR # STALLS 46 EXISTING LOW-INCOME UNITS 1 / UNIT 46 9 PROPOSED MARKET-RATE UNITS 1 / UNIT 9 COMMERCIAL 3,425 SF 1 / 300 SF 12 TOTAL REQUIRED:67 REQUIRED:3 PROVIDED:5 TOTAL PROVIDED:(INC. ADA PARKING)71 TYPE REQUIRED PROVIDED LONG-TERM 49 50 SHORT-TERM 17 18 ADA REQUIREMENTS: (1 PER 25) BICYCLE PARKING: PARKING REQUIRED: AFFORDABLE UNITS PROVIDED ON SITE:81% (46 EXISTING AFFORDABLE UNITS / (46+9 PROPOSED MARKET-RATE UNITS) AFFORDABLE INCENTIVES PURSUED:43% DENSITY BONUS PROPOSED DENSITY BONUS:[49.42 (E) DU + 5.33 DU] / 38.4 DU = 43% DENSITY CALCULATIONS: ALLOWABLE DENSITY PER ZONE: (C-S - 24 DU / ACRE) 1.6 ACRES x 24 UNITS = 38.4 DU EXISTING DENSITY: 29% DENSITY BONUS (USE-0809-2015) 49.42 DU PROPOSED DENSITY CALCULATIONS: AVERAGE NATURAL GRADE ELEVATION: AREA:8,243 SF LOT COVERAGE (FOOTPRINT):4,312 SF FAR: PROJECT INFO HEIGHT:36'-6" STORIES:2 OCCUPANCY:B (RETAIL / OFFICE), R-2 (APARTMENTS) CONSTRUCTION TYPE:VB USE:SYSTEM: SPRINKLERS:B, R-2 NFPA 13 BUILDING AREAS: ROOM OR FLOOR USE AREA/ OCC LF OCCUPANCY #EXITS REQUIRED FUTURE T.I.BUSINESS 3,425 SF / 200 GROSS 17.1 1 1-BEDROOM UNIT RESIDENTIAL 420 SF / 200 GROSS 2.1 1 PER UNIT ROOM OR FLOOR USE AREA/ OCC LF OCCUPANCY #EXITS REQUIRED STUDIO (QTY 2)RESIDENTIAL 410 2.05 PER UNIT 1 PER UNIT STUDIO (QTY 2)RESIDENTIAL 422 2.11 PER UNIT 1 PER UNIT 1-BEDROOM UNIT (QTY 4) RESIDENTIAL 460 2.3 PER UNIT 1 PER UNIT ROOM OR FLOOR AREA/ OCC LF OCCUPANCY #MALE FEMALE FUTURE T.I.N/A (WC, LAV, UR.)(WC, LAV) TOTAL BUILDING AREA:8,243 SF TOTAL COVERED DECK/PATIO AREA:588 SF TOTAL UNCOVERED DECK/PATIO AREA:0 SF BUILDING INFO FIRST FLOOR: SECOND FLOOR: PLUMBING FIXTURE COUNT: (PER CPC TABLE 422.1, AND TABLE A) Packet Pg. 119 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site NOPARKINGNOPARKINGNO PARKING2.5' 461.414 S66° 31'31.08"W N23° 20' 55.00"W150.387N66° 39' 05.00"E 478.635L=150.372, R=8971.2241 -50'-0"187'-5" 15 15 (E) MULTI-FAMILY RESIDENCES 3680 BROAD STREET APN: 053-231-047 NOPARKINGNOPARKING180 179178 178 176 178175 174 173 1771761751741731781771761751741737 (N) MIXED-USE BUILDING 3680 BROAD STREET APN: 053-231-047 FFE: 178.5 4 5 5 9 6 TYP TYP 8 32 10 TYP 1 8 TYP 25'-0" WETLAND SETBACK 11 8'-1" (E) SIDEWALK 14'-912"19'-1112"11'-4"25'-1" 73'-634" TO NEAREST ADJ. BLDG. 14 13 TYP 12 20'-0" DRAINAGE EASEMENT 10'-0" STREET TREE & P U B L I C UTILITY EASEMENT 10'-0" STREET DEDIC A T I O N EASEMENT 10'-0" OFFER FOR PU E & STREET TREE EASEM E N T 50' HOUSING SETBAC K FROM RIGHT-OF-WAY KEYNOTES (N) STREET TREE (REFER TO PLBLDG-3371-2016) (N) LONG-TERM BIKE LOCKERS (REFER TO PLBLDG-3371-2016) (N) TRANSFORMER (REFER TO PLBLDG-3371-2016) (N) TRASH ENCLOSURE (REFER TO PLBLDG-3371-2016) (N) ACCESSIBLE PARKING STALLS AND ACCESS AISLE (REFER TO PLBLDG-3371-2016) (N) BUILDING AWNING OVERHEAD, SHOWN DASHED (N) PARKING STALL PER SLO CITY STANDARDS AND (REFER TO PLBLDG-3371-2016) (N) BIKE RACKS (REFER TO PLBLDG-3371-2016) (E) PROPERTY LINE (N) CONCRETE STAIRS (REFER TO PLBLDG-3371-2016) (N) AC PAVING (REFER TO PLBLDG-3371-2016) (N) MULTI-FAMILY RESIDENTIAL BUILDING (REFER TO PLBLDG-3371-2016) (E) EASEMENT(S) (N) COVERED PARKING BUILDING (REFER TO PLBLDG-3371-2016) (E) FIRE HYDRANTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A1.0 1- ENLARGED SITE PLAN SCALE: 1” = 20’ N SITE KEY PLAN SCALE: 1” = 100’ N Packet Pg. 120 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site N.T.S. A1.1 APPROVED UTILITY PLAN FROM PLBLDG-3371-2016 Packet Pg. 121 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site 36'-0"11'-0"120'-0"50' TO R.O.W.6"6"34'-4"84'-8"9'-0"1 BR 420 SF FUTURE T.I. SPACE COMMERCIAL 1565 SQ. FT. FUTURE T.I. SPACE COMMERCIAL 1035 SQ. FT. FUTURE T.I. SPACE COMMERCIAL 825 SQ. FT. UP UP MECH. 115 SF 43'-0"16'-6"29'-6"19'-1"11'-11" 6'-512"18'-3"9'-11"18'-3"9'-11"18'-3"9'-11"15'-11"3'-112"9'-0" FIRE RISER A2.0 FIRST FLOOR PLAN SCALE: 3/32” = 1’-0” N Packet Pg. 122 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site 36'-0"36'-0"120'-0" 1 BR 460 SF 1 BR 460 SF STUDIO 410 SF STUDIO 422 SF STUDIO 422 SF 1 BR 460 SF STUDIO 410 SF 1 BR 460 SF DN DN DECK 66 SF DECK 66 SF DECK 66 SF DECK 66 SF DECK 66 SF DECK 66 SF DECK 60 SF6"6"DECK 66 SF 9'-312"19'-6"1'-1"19'-6"2'-0"19'-6"8'-112"17'-6"11'-11"3'-9"3'-9"2'-6"1'-6" 29'-1012" 5'-612" 29'-712"29'-712"30'-1012" 4'-7"1'-512"15'-412"4'-0"16'-712"16'-712"4'-0"15'-412"5'-10"19'-6"8'-8"19'-6"8'-8"19'-6"8'-6"17'-6"11'-4" A2.1 SECOND FLOOR PLAN SCALE: 3/32” = 1’-0” N Packet Pg. 123 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site 4'-1112" 29'-2" 10'-312"13'-11"29'-2" 12'-112"8'-212"10'-512"7'-312"11'-0"38'-1" BEDROOM 120 SF KITCHEN/DININGLIVING BATH A2.2 ENLARGED FIRST FLOOR PLAN - one bdroom SCALE: 3/16” = 1’-0” ENLARGED SECOND FLOOR PLAN - ONE BEDROOM SCALE: 3/16” = 1’-0” ENLARGED SECOND FLOOR PLAN - STUDIO SCALE: 3/16” = 1’-0” 4'-1112"5'-1"29'-2" 10'-312"15'-812"10'-712"13'-11" BEDROOM 110 SF BATH LIVING/DINING KITCHEN 12'-1112"2'-912"5'-112"8'-312" 29'-2"5'-4"9'-112"14'-512"29'-2" STUDIO 420 SF BATH N NN Packet Pg. 124 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site A3.0 EAST ELEVATION SCALE: 3/32” = 1’-0” NORTH ELEVATION SCALE: 3/32” = 1’-0” SOUTH ELEVATION SCALE: 3/32” = 1’-0” EAST SOUTH NORTH WEST EAST SOUTH NORTH WESTEAST36'-6"ABOVE A.N.G.AVERAGE NATURAL GRADE 173.75' FIRST FINISH FLOOR 0'-0" 178.5' SECOND FINISH FLOOR 13'-6" 192.0' Packet Pg. 125 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site ELEVATION SCALE: 1/16" = 1 EAST SOUTH NORTH WEST 32 5 5 4 1 5 4 A3.1 WEST/BROAD STREET ELEVATION SCALE: 3/32” = 1’-0” MATERIALS 1. ROOFING STANDING SEAM METAL ROOF 2. BODY 1 CORRUGATED METAL SIDING: KINGSPAN 900 HIGH RIB (WALL) OR SIMILAR 3. DOORS SHERWIN WILLIAMS BRANDYWINE SW 7710 OR SIMILAR LIGHT FIXTURES HI-LITE H-18112 IN BKO1 BLACK OR SIMILAR DARK SKY COMPLIANT FIXTURE 5. ACCENT 2 FIBER CEMENT PANELS, TRIM, COLUMNS SHERWIN WILLIAMS BROWSE BROWN SW 6012 OR SIMILAR 4. ACCENT 1 METAL AWNINGS, METAL PANEL, RAILING FRAMES SHERWIN WILIAMS BLACK FOX SW 7020 OR SIMILAR Packet Pg. 126 Item 9 IRON WORKS MIXED USE 3680 BROAD STREET, SAN LUIS OBISPO, CA DATE: 08/02/2018 805.541.1010 539 Marsh StreetSan Luis Obispo, CAinfo@tenoverstudio.com tenoverstudio.com SET NOT FOR CONSTRUCTION All dimensions to be verified on site A4.0 MODEL IMAGES Packet Pg. 127 Item 9 Packet Pg. 128 Item 9 Packet Pg. 129 Item 9 Packet Pg. 130 Item 9 Packet Pg. 131 Item 9 Packet Pg. 132 Item 9 Packet Pg. 133 Item 9 Page intentionally left blank. Packet Pg. 134 Item 9