Loading...
HomeMy WebLinkAboutItem 2 - Northwest Corner at Broad and Tank Farm (660 Tank Farm and 3985 Broad) PLANNING COMMISSION AGENDA REPORT SUBJECT: Review of an Amendment to the Airport Area Specific Plan amending the land use designation from Business Park (BP-SP) to Community Commercial with Special Focus Overlay (C-C-SF-SP); General Plan Amendment and Rezone; Vesting Tentative Map (Tract 3115) to create seven (7) lots; review of a commercial center with 49,000 square feet, and assisted living facility with 139 units; creek setback exception, and consideration of a CEQA Initial Study-Mitigated Negative Declaration environmental determination. PROJECT BY: David Watson, Contract Planner ADDRESS: 660 Tank Farm Road Phone Number: 805-704-8728 3985 Broad Street E-mail: dave@watsonplanning.us FILE NUMBERS: SBDV-1483-2018, Brian Leveille, Senior Planner EID-1484-2018, ARCH-1486-2018 Phone Number: 805-781-7166 SPEC-1492-2018 E-mail: bleveille@slocity.org FROM: Xzandrea Fowler Deputy Director RECOMMENDATION Adopt the Draft Resolution (Attachment 1) that recommends approval of project-related entitlements to the City Council (including CEQA Findings and Mitigation Measures ). The project entitlements include an amendment to the Airport Area Specific Plan, General Plan Amendment, Rezone, Subdivision, Architectural Review, and Creek Setback Exception. SITE DATA Applicant NKT Development LLC Westmont Development LP Representative Carol Florence, Oasis Associates Zoning Community Commercial with Special Focus Overlay (C-C-SF) Airport Area Specific Plan Business Park Overlay (BP-SP) Airport Area Specific Plan Conservation Open Space Overlay (C/OS-SP) General Plan Community Commercial with Special Focus Overlay (C-C-SF) Conservation Open Space (C/OS-SP) Site Area 10.7 acres Environmental Status An initial study of environmental impact has been prepared with a recommendation for a Mitigated Negative Declaration. Meeting Date: April 10, 2019 Item Number: 2 Packet Page 6 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 2 1.0 COMMISSION’S PURVIEW The Planning Commission’s role is to make a recommendation to the City Council regarding the above described entitlements and Mitigated Negative Declaration (Draft Resolution, Attachment 1). 2.0 PREVIOUS REVIEW 2.1 Planning Commission On June 13, 2018 the Planning Commission conducted a conceptual policy review of the proposed development project. The purpose of the review was to consider the special focus area policies and provide any direction to staff and the applicant prior to formal review of the project entitlements. The Commission was not asked to vote on the project, but to provide comments that would guide continued planning efforts on the proposal. Commission comments focused on site planning and greater integration of the commercial center and assisted living facility. Connectivity between the uses, enhanced pedestrian and bicycle routes, strong commercial presence at Broad and Tank Farm, considerations for shared service area between the uses, and the exploration of more independent living options were all noted during the Commission’s discussion (Attachment 4, PC staff report and meeting minutes). 2.2 Architectural Review Commission The ARC reviewed the proposed project on October 15, 2018 for consistency with Community Design Guidelines and applicable AASP guidelines. During their review the ARC provided direction on building and site design issues (Attachment 5, ARC Staff report and meeting minutes). 3.0 PROJECT INFORMATION 3.1 Site Information/Setting The site’s topography is relatively level and currently supports non-native annual grassland and ruderal habitats. There is an existing soil stockpile on the southern area, which is to be used for the site grading of the proposed development. The site’s north and west boundaries are defined by drainage swales that flow west to the confluence with Orcutt Creek. The existing riparian habitat is generally in poor condition and will be enhanced as part of the project. The project site is located at the northwest corner of Broad Street and Tank Farm Road within the Airport Area Specific Plan (AASP). Surrounding uses include SESLOC Federal Credit Union to the north, a mobile home park to the west, Marigold Shopping Center to the east, and MindBody offices and the Edna Valley Market and Gas Station to the south. Orcutt Creek is located along the western boundary of the project site. 3.2 Project Description The applicant is proposing a seven (7) lot subdivision on two parcels with a combined area of approximately 10.07 acres. Lot 1 of Vesting Tentative Tract Map (VTTM) 3115 would include the assisted living facility on 4.79 acres, and Lots 2-7 would comprise the commercial shopping center on 5.28 acres. The proposal is located within the Airport Area Specific Plan (AASP) located at 3985 Packet Page 7 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 3 Broad Street and 660 Tank Farm Road, San Luis Obispo, CA 93401 (APNs: 053-421-003 and -004). The two-parcel, 10±-acre property, contains a single-family residence at 660 Tank Farm Road, while 3985 Broad Street is currently vacant. The proposed development project includes a retail shopping center and assisted living facility. The proposed retail shopping center consists of an anchor retail grocer space and additional buildings for retail/restaurant use totaling 49,269 square feet in six (6) independent detached buildings. The assisted living facility would occupy the westerly portion of the development and include approximately 139 living units, support and administrative space in 133,656 square feet, serving residents of 60 years in age and older. Figure 1. View from Tank Farm Road and Broad Street looking Northwest Westmont Living is a retirement community that provides a spectrum of living options. State licensing is required to operate an assisted living facility. However, the level of assisted service is tailored to the individual needs of each resident. This allows each resident to “age in place” rather than relocate as their service needs change. Based on Westmont’s operations, approximately 50% of residents are considered independent living. These are residents of the community but are not utilizing Assistance with Daily Living (“ADL”) Services. The other 50% of residents require some form of assistance. For example, ADL’s include medication reminders, dressing or bathin g assistance, transportation or mobility utilizing the assistance services or are memory care residents. The project is proposed for development in three main phases beginning with mass grading and subsequent development of the Westmont assisted living project (Figure 2, below), followed by the retail portion of the project. Packet Page 8 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 4 Figure 2. Project Phasing Plan Additional proposed project details include: 1. A seven-lot subdivision, six (6) commercial lots ranging in size from 0.37 acres to 1.76 acres, and one (1) assisted living site of 4.79 acres; 2. The assisted living facility would include 111 assisted living units. Of these, approximately 50 - 60% are independent living, with the balance being assisted living. and 28 memory care beds, constructed in two phases; 3. Phase 1 of the assisted living = 72 assisted units and 28 memory care beds comprising 98,473 square feet (49,610 sf 1st Floor, 48,863 sf 2nd Floor) in a single building. Phase 1 parking and site improvements would consist of 70 parking spaces; 4. Phase 2 of the assisted living = 39 assisted units comprising 35,183 square feet (17,764 sf 1st Floor, 17,418 sf 2nd Floor) in an expanded building attached to the main Phase 1 facility; 5. Assisted living amenities at the site are proposed to include full meal services, entertainment and exercise rooms, movie theater and beauty-barber services; 6. As a 24-hour operation, the assisted living facility is expected to employ approximately 80 full and part time staff. At any given time, as many as 18 employees would be on site for a given shift; Packet Page 9 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 5 7. The assisted living facility will include various delivery receiving and service needs throughout each day, and will accommodate family and guest visitors throughout each day; 8. Assisted living parking is proposed at 70 parking spaces dedicated to residents and staff; 9. The commercial site is proposed to be developed in 1 phase, with construction of each of the six (6) proposed businesses at varying timeframes based on project demand; 10. Commercial center site improvements include 214 vehicle parking spaces, 11 motorcycle spaces, 16 bicycle racks and 16 bike lockers to serve the proposed uses; 11. Commercial retail uses, building and lot sizes, and associated parking on each distinct commercial parcel include: a. Lot 2 Retail 0.54 ac / 23,718 sq ft Bldg = 8,026 sq ft Parking = 19 b. Lot 3 Retail 0.37 ac / 16,007 sq ft Bldg = 3,205 sq ft Parking = 10 c. Lot 4 Restaurant 0.75 ac / 33,015 sq ft Bldg = 4,835 sq ft Parking = 39 s d. Lot 5 Restaurant 0.66 ac / 28,920 sq ft Bldg = 4,982 sq ft Parking = 34 s e. Lot 6 Retail-Rest. 1.20 ac / 52,196 sq ft Bldg = 6,240 sq ft Parking = 34 s f. Lot 7 Grocer 1.76 ac / 76,499 sq ft Bldg = 21,981 sq ft Parking = 81 s 5.28 ac / 230,355 sq ft Bldg = 49,269 sq ft Total = 217 12. Demolition of the existing single-family residence on Tank Farm Road, 13. Amendment to the Airport Area Specific Plan to modify the land use designation from Business Park with Specific Plan Overlay (BP-SP) to Community Commercial with Special Focus Area and Specific Plan Overlay (C-C-SF-SP), 14. General Plan Amendment and rezone for the 1.37 acre parcel at 660 Tank Farm Road modifying the land use designation from Business Park to Community Commercial and the Zoning Designation from Business Park (BP-SP) to Community Commercial with Special Focus Overlay (C-C-SF-SP). 15. Design Exception for Tank Farm Road frontage improvements to allow 11-foot vs. 12- foot wide travel lanes, and 16. Frontage and on-site improvements. Two points of access from Tank Farm Road are proposed via a north -south driveway that is shared with the assisted living portion of the site, and a signalized intersection at the MindBody intersection that connects to the Industrial Way/Broad Street signalized intersection. Access from Broad Street is provided by a driveway located along the northerly property line. This driveway will also provide access to the SESLOC Federal Credit Union building to the north. The existing right-in/right-out driveway access to SESLOC from Broad Street would be eliminated. The site plan is configured with the smaller commercial buildings near and along the Tank Farm- Broad Street intersection, with parking located between the perimeter buildings and the anchor grocer. The anchor building is located at the northwest quadrant with its entry set at the southeast corner of the footprint near the center of the site. The remaining buildings are oriented on the Broad Street and Tank Farm Road frontages. Packet Page 10 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 6 Pedestrian access from the public sidewalk is provided at each corner of the site and at intermediate points, both on Broad Street and Tank Farm Road. At the corner of Tank Farm Road and Broad Street, a pedestrian walkway leads from the intersection diagonally between Buildings Three and Four to an interior dining patio. From the northeast corner at the entry drive on Broad Street, the pedestrian access passes through a patio and between Buildings Five and Six to the interior parking area and storefronts. Internal walkways link the retail buildings and connect to the assisted living portion of the project and the SESLOC property. The commercial buildings are designed with shed roof forms and overhangs with board and batten siding. Materials consist of a mix of storefront, plaster surfaces and vertical siding which are incorporated to provide variation in wall finishes. Other architectural elements include cantilevered awnings, canopies and trellis elements. The color selections for the project reflect a neutral earth tone palette. The proposed two-story, thirty-two (32) foot high assisted living building’s design incorporates an architectural style and materials consistent with the surrounding neighborhood. The color palette is neutral, and materials consist of a mix of Alumawood, Hardie siding, stucco, board and batten, and stone. The assisted living facility design incorporates use of simple shed roof forms, and board & batten and lap siding, with the intent to provide complementary forms and m aterials between the assisted living and retail project components. The proposed project has been designed to collect stormwater runoff from the seven (7) proposed buildings, landscaping, parking and drive aisles, and direct the water into underground storage facilities as a strategy to address current post-construction stormwater regulations. The impervious areas on site have been designed with gradients to direct stormwater through a storm drain system that will route the stormwater to the two (2) proposed underground storage facilities. Mitigation of impacts to 0.19 acres of seasonal wetland and ephemeral drainage area is incorporated into the project design and proposes a 3:1 replacement ratio with the enhancement of approximately .60 acres along the Orcutt Creek corridor. The enhancement plan provides for the removal of invasive Figure 3. Wetland Replacement and Riparian Enhancement Areas Packet Page 11 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 7 non-native species and planting of native plans in the northwest corner of the site and creek setback areas along Orcutt Creek (Figure 3, above) 4.2 Airport Area Specific Plan Amendment To be consistent with the LUCE Update in 2014, the proposed amendment to the AASP is to modify the AASP land use designation from Business Park-Specific Plan to Community-Commercial- Specific Plan with Special Focus Overlay (C-C-SF-SP). The approximately 1.4 acre site at 660 Tank Farm Road at the westerly end of the site adjacent to Orcutt Creek also requires a General Plan Amendment and Rezone to be consistent with the application of the C-C-SF-SP zoning to the whole project site (Figure 4, below, and Attachment 1, Exhibit A). Attachment 1, Exhibit B includes proposed text amendments to the AASP to incorporate the proposed project into the Specific Plan and to reflect the Special Focus Area. Figure 4. Northwest Corner site plan Packet Page 12 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 8 4.0 EVALUATION 4.1 Project Site Plan The proposed site plan provides for needed points of connection to the City’s utilities and circulation systems. The retail center and assisted living buildings will have domestic water, recycled water, sewer, and fire services. The proposed street frontage improvements for both Tank Farm Road and Broad Street consist of curb, gutter and sidewalk and parkways along the project frontages as depicted in the AASP. The proposed Broad Street entry to the shopping center will require removal of the right-in/right-out entry to the SESLOC property, north of and adjacent to the shopping center. All roadway improvements reflect the proposed sections noted in the AASP with the exception that the travel lanes on Tank Farm Road are noted as eleven (11) feet versus twelve (12) feet. Constraints associated with a “full width” build-out of this road include: 1) conflicts with the existing drainage facilities at the MindBody intersection; 2) relocation of the existing traffic signal pole and facilities; and 3) a sixteen (16) foot jog in the west bound through lane at the intersection to otherwise widen to the full width Public Works requirements. Figure 5. Northwest Corner site plan Packet Page 13 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 9 4.2 Site Circulation As noted previously, the project site currently has accommodated off-site circulation goals of the Circulation Element; namely the extension of the Industrial Way-Broad Street roadway through the SESLOC site and continuing to the MindBody signalized intersection at Tank Farm Road, and the potential connection to the secondary access to the project at 650 Tank Farm Road – also exiting on this perimeter road connection. Access to this perimeter road will be provided on the assisted living facility property to the 650 Tank Farm Road project site to the west via a bridge crossing on Orcutt Creek. This bridge will be designed and installed consistent with the conditions, mitigation measures, and requirements of the project at 650 Tank Farm Road. 4.3 Storm Water Management The proposed project has been designed to collect stormwater runoff from the seven (7) proposed buildings, landscaping, parking and drive aisles, and direct the water into underground storage facilities. The impervious areas on site have been designed with slopes and grading to direct stormwater through a storm drain system that will route the stormwater to two (2) proposed underground storage facilities. The Project’s Storm Water Control Plan has been prepared to demonstrate how the underground storage facilities will treat and retain the 95th percentile storm event on site, while managing the peak flows for the 2-year through 100-year storm event. The proposed stormwater system has been designed to reflect the City of San Luis Obispo’s Post-Construction Storm Water Requirements (PCR) that requires that the post-developed flows not exceed those of the pre-developed conditions. 4.4 Project Phasing The project is proposed to be constructed in phases by the applicant. Current phasing plans call for construction of the project in generally 3 phases. Phase 1 would include the perimeter roadways and utility improvements for the initial 100 assisted living facility units and associated support services. Phase 2 would be the development of the commercial center and Phase 3 would be the completion of the last 39 units of the assisted living facility. Generally, subdivision improvements need to be approved and constructed prior to building permit issuance. Staff has included conditions of approval that recognizes the applicants request for phased improvements. Additional detailed analysis would be required for a determination of acceptable infrastructure phasing (Draft Resolution, conditions 19 & 20). The applicant’s proposed phasing plan requires further detailed submittals to address various details such as multi-modal site access, access controls, grading and drainage, emergency vehicle access, etc. 4.5 General Plan Policy Consistency The 2014 General Plan establishes a number of community goals, policies and programs for development that relate to the proposed site. These include: • Special Focus Area #12 • Neighborhood Connections Packet Page 14 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 10 • Mixed-Use Developments and Convenience • Neighborhood Compatibility • Airport Area Standards 4.6 Special Focus Area #12. General Plan Policy 8.13 provides that the subject site would be a mixed-use development, providing uses consistent with the “Community Commercial” and “Office” designations. This policy calls for a strong commercial presence at the corner of Tank Farm and Broad Street, and to emphasize creek protection and circulation connectivity as noted above in any land plan. As discussed above, the project was brought to the Planning Commission on June 13, 2018 for a conceptual policy review to receive early, high-level comments on the projects potential consistency with the Special Focus Area policies. The applicant has made a number of changes to the project following Planning Commission and Architectural Review Commission feedback (Applicant project narrative and ARC response, Attachments 2 & 6). Articulated walkways have been added within and along the perimeter of the uses, as well as enhanced connections between the commercial uses and assisted living facility. Improvements have been made to the commercial service areas located along the central road access to better screen loading and unloading functions for the uses. This access has also been revised with a curvilinear drive and landscaping to minimize visibility from off-site. Pedestrian meeting areas/plazas have been added to the retail center and better connect to pedestrian and bicycle routes into the site. 4.7 Neighborhood Connections. General Plan Policies 2.2.4 and 2.2.5 discuss planning for connectivity both internally to a given project, and as that project relates to the larger neighborhood context. The subject site is located at the northwest corner of Tank Farm Road and Broad Street and provides pedestrian and bicycle connections to the nearby employment centers at MindBody and along the Broad Street corridor, and to retail services at the Marigold Shopping Center. Additionally, vehicle circulation internal to the project and to connect to adjoining development is enhanced, providing additional access options to motorists working or visiting the area. The internal access patterns for the site promote accessibility from off-site and facilitate internal access for visitors to the various retail and food service businesses proposed for the development. 4.8 Mixed-Use Developments and Convenience. General Plan Policies 2.3.1 and 2.3.6 encourage mixed-use projects to integrate complementary uses close to one another, and to ultimately cut down on vehicle traffic by making these mixed-use projects accessible to other nearby neighborhoods. The design of the proposed project adheres to the General Plan policies encouraging retail shopping and food service options located close to employment centers, transportation corridors and resident needs. 4.9 Neighborhood Compatible Development. General Plan Policy 2.3.9 sets several goals for new development (specifically residential, but equally applicable to “infill” projects) within established neighborhoods. The vicinity of the proposed project includes a wide mix of commercial, office, professional, business park, manufacturing, industrial and residential uses. The proposed mixed-use project includes the potential for a mix of these uses as allowable land use types. Architectural design of the proposed project is also consistent with architectural stylings found in the nearby area. As analyzed further below, the project also incorporates many of these established architectural styles into a well-designed center that is compatible with scale and design of these neighborhoods. Packet Page 15 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 11 4.10 Airport Area Specific Plan Consistency First adopted by the City Council in 2005, the Airport Area Specific Plan (AASP) included a series of goals, policies and programs to comprehensively guide development of the Planning Area. Additional guidelines and development standards are included in the AASP, as well as infrastructure requirements and a plan for implementation of the Plan. In 2014 the AASP was updated to reflect current planning standards for the area. Overall goals of the Specific Plan include: • Provide a framework to move from County developments primarily focused on heavier industrial and manufacturing uses to a blend of these established uses, both inside and outside the City, with new uses focused on lighter industrial and manufacturing uses, professional and business park developments, employment centers, retailing services to support daytime customer demands and limited numbers of residential developments surrounding the Planning Area. • Plan for proposed development, including annexations within the Planning Area, so that public facilities are developed concurrently with new development in a rational and cost- effective fashion. • Expand the use of bicycles and pedestrians within the Plan Area as an alternative to increasing vehicular trips. • Protect and enhance natural resources within the AASP, including emphasis on maintaining visual qualities of the surrounding hills and open space areas and protection of creek corridors, wetlands and habitat qualities. 4.11 San Luis Obispo County Airport Land Use Plan Consistency On August 15 and again on September 19, 2018 the Airport Land Use Commission (ALUC) considered a referral of this project from the City. On September 19th the ALUC found the proposed project, including amendments to the City’s AASP, were consistent with the County’s ALUP. The The ALUC’s finding of consistency (Attachment 7) and recommended conditions are incorporated into the draft resolution recommending Council approval of the project. 4.12 Site Design and Access The project is oriented in a horizontal mixed-use configuration, with the retail commercial uses aligned on Broad Street and at the intersection with Tank Farm Road. The assisted living facility is located to the western edge of the property. Vehicle access is planned with right turn in and out movements only for the commercial center at both Broad and Tank Farm. A signalized intersection along the western edge to match with the MindBody signal on Tank Farm will provide primary access to the assisted living facility and secondary access for the commercial center for east bound Tank Farm Road traffic. The road planned for the signalized intersecti on would also continue along the western edge of the property, tie into the perimeter road around the SESLOC facility, and continue to the Board Street intersection with Industrial Way. This circulation pattern is consistent with the Circulation Element standards for this area. As a result of the construction of the new right turn access to the commercial center at Broad Street, the existing right turn in and out access for SESLOC will be closed as a result of this project. Packet Page 16 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 12 Provisions for an access drive over Orcutt Creek between the nearby Agera Grove Investments mixed- use development (approved for 650 Tank Farm Road) and this property is included with the applicant’s 2/5/19 Sheet SP-1 site plan. The approvals for the Agera project included options for two differing alternatives for secondary access, and the preferred alternative was to connect easterly over Orcutt Creek into the perimeter roadway planned for the subject property. This connection point in alignment with the northern parking lot access for the assisted living facility would provide secondary access for this adjoining project to Tank Farm Road at the MindBody signalized intersection. The design and construction of this bridge would be the responsibility of the Agera development. This connection would also provide an opportunity to connect pedestrian and bicycle access form this site to the services and facilities planned for the Northwest Corner project. Conditions have been added to require this easement/access be shown on the Final Map or other appropriate instrument to the satisfaction of the Public Works Director/City Attorney. Pedestrian access to the site would primarily come from various points of entry planned along the Broad and Tank Farm frontages. Figure 1 describes several points where sidewalk access into the site is provided. Once inside the site, there are a number of pedestrian links (differentiated by separated pedestrian aisles, alternate paver and colored concrete materials, landscaping and trellis markers) between the retail and assisted living sites to facilitate safe pedestrian access throughout the mixed-use project. Pedestrian access between the SESLOC site and this project is also planned. 4.13 Architectural Design Review Following standards included in the AASP and Community Design Guidelines, the project endeavors to create a complimentary massing and scale of buildings located on the 10-acre site while maintaining some uniqueness between buildings architecturally. The commercial center is a more agrarian, rural architectural style. The assisted living facility is a more contemporary collection of various design elements taken from the adjoining commercial center and surrounding commercial neighborhoods. The commercial center consists of six (6) detached buildings combining heavy shed roofs, one-story storefront massing that includes windows on the pedestrian level and upper wood/board and batten siding leading to the roof elements. The assisted living facility includes an eclectic mix of vertical and horizontal siding and stucco exterior walls, featuring some wooden and stone pilasters and columns, with use of trellis, canopies, awnings and arbor entry and shade elements intermixed within the various exterior treatments, along with flat, standing seam and parapet roofs with some exaggerated overhangs. Commercial center materials include a standing seam roof, storefront glazing with anodized aluminum frames, metal trellis and canopy features, stucco and vertical board and batten siding. The assisted living facility materials include vertical board and batten and horizontal lap siding, stone and wood columns, use of heavy timber beams and roof kickers, vinyl framed windows with trim, decorative corbels and facia treatments, and standing seam metal roofs. Colors for both projects follow subdued natural earth tone themes. The commercial center has a more uniform application of colors on all seven buildings including board and batten and shed roof elements at the corner entries to the buildings, use of stucco exteriors between these corner features, and accenting these long walls with trellis and canopy features. Packet Page 17 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 13 The landscape concept is designed to create a “softscape” character including natural, ornamental, and agricultural landscapes. The project design provides an attractive and sustainable landscape that complements and is consistent with neighboring urban landscapes. The proposed two-story, thirty-two (32) foot high Assisted Living building’s design incorporates an architectural style and materials consistent with the surrounding neighborhood. The color palette is neutral, and materials consist of a mix of Alumawood, Hardie siding, stucco, board and batten, and stone to create a natural look. The assisted living facility design reflects many of the proposed features for the shopping center with use of simple shed roof forms, board & batten and lap siding, providing consistency between the two projects. The project will also include use of wood columns and beams and stone veneer to accent the main entry. Individual wall planes and surfaces are articulated vertically and horizontally to provide variation dimensionally. 4.5 Architectural Review Commission The ARC reviewed the proposed project on October 15, 2018. During their review the ARC provided direction on a number of building and site design issues. The applicant has responded to ARC comments and (Attachment 5, 10-15-2018 Staff Report and meeting minutes) included more internal connectivity and articulation to the pedestrian paths of travel, expand variety and landscape treatments along project frontages, particularly Tank Farm Road, modify building designs to simplify materials and roof forms, use of canopies and arcades to tie the walkways together and avoid white and mustard color treatments, preferring a more subdued color theme. With these comments the ARC recommended the Planning Commission find the project consistent with AASP and Community Design Guideline standards for development in this area. 4.6 Orcutt Creek Riparian Corridor The proposed project abuts Orcutt Creek as it extends along the western edge of the property, near the assisted living facility. The project proposes a creek setback exception, primarily to allow a uniform extension of the proposed perimeter road to extend along this edge of the property (Figure 6, below). Zoning standards require a 35’ setback, and for the majority of the site adjoining the creek this minimum setback is provided. There are three (3) areas where the placement of the road infringes on this setback. Two of these areas paralleling the creek, totaling just under 5,000 sf in area, vary between 1’-12’ in depth. The third area would be the crossing of the creek with the bridge access from the Agera Grove development at 650 Tank Farm Road. As noted in Figure 3 above, an area for wetlands mitigation is proposed that can be used in addition to the corridor enhancement areas to offset the loss of area with this creek setback exception. In staff’s analysis, the creek setback exception request can be supported since the encroachment is minor and the project incorporates mitigation and creek restoration. The creek restoration consists of removal of invasive non-native species and replanting with native plantings1. 1 COSE Policy 8.7.2 Enhance and restore open space. B. Establish self-sustaining populations of native species that were historically found in natural habitat areas. 2. To reverse historical trends of creek channelization and modification, re-establish native riparian vegetation. Packet Page 18 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 14 Figure 6 – Creek Setback Exception Areas Adjoining Assisted Living Facility 4.7 Parking Assisted Living Facility The applicant has included the following parking calculation for the assisting living (continuing care community use which staff has verified is consistent with and exceeds requirements of the Zoning Regulations. Shopping Center The shopping center configuration includes six separate buildings/parcels. The applicant is requesting a 20% Shared Parking Reduction based on the proposal for all uses in the center to provide for shared parking between all six parcels. The uses shown in the below table anticipate some uses with higher parking demands and may represent a “worst case” scenario with four of the six uses representing higher parking demands that are already anticipated in the parking calculations with the 20% Two areas vary between 1’-12’ in depth. Total area = 4,963 sf Packet Page 19 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 15 requested reduction. With the excess of parking provided for the assisted living use, there also would likely be no “spillover” of parking to the retail center. 4.8 Environmental Review An initial study has been prepared in accordance with the California Environmental Quality Act (CEQA) to evaluate the potential environmental effects of the proposed project. A Mitigated Negative Declaration (MND) is recommended for adoption (see Reading File). Mitigation measures in the areas of Air Quality, Biological, Cultural Resources, Noise, and Transportation, are recommended to reduce potential impacts to less than significant levels. The Draft IS/MND was released for the 30-day public review period on April 5, 2019 and the public review period will conclude on May 4, 2019. Comments received on the Draft IS/MND will be incorporated as appropriate into the Final IS/MND. The draft IS/MND is available at the following website: http://www.slocity.org/government/department-directory/community-development/documents- online/environmental-review-documents 4.9 Signs The applicant’s submittal includes a conceptual signage in terms of locations, size, and general sign types for the commercial center. Sign programs are an effective way to establish ongoing requirements to ensure signage is coordinated and compatible with the development and surrounding area in projects with multiple tenants and buildings. Staff has included a recommended condition of approval which requires Community Development Director approval of a final sign program. Packet Page 20 SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018, SPEC-1492-2018 (660 Tank Farm Road, 3985 Broad Street) – Planning Commission 4-10-2019 Page 16 5.0 OTHER DEPARTMENT COMMENTS All City Departments have reviewed the project and have provided comments that are incorporated into the staff report and recommended resolution as conditions of approval and code requirements. 6.0 ALTERNATIVES 6.1 Continue the project with direction to the applicant and staff on pertinent issues. 6.2 Deny the project based on findings of inconsistency with the AASP, General Plan, Design Guidelines or Subdivision Regulations. 7.0 ATTACHMENTS 1. Draft Resolution including Exhibits “A” and “B” 2. Applicant’s Project Narrative 3. Project Plans 4. 6-13-2018 Planning Commission Conceptual Policy Review Staff Report and Minutes 5. 10-15-2018 ARC Staff Report and minutes 6. Applicant ARC revision memorandum, December 20, 2018 7. 9-19-2018 Airport Land Use Commission Determination of Consistency 8.0 READING FILE 1. Draft Initial Study and MMRP Packet Page 21 RESOLUTION NO. PC-XXXX-19 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF SAN LUIS OBISPO RECOMMENDING THE CITY COUNCIL ADOPT THE AIRPORT AREA SPECIFIC PLAN AMENDMENTS AND ASSOCIATED GENERAL PLAN AMENDMENT AND REZONE, VESTING TENTATIVE TRACT MAP, CREEK SETBACK EXCEPTION, AND ARCHITECTURAL DESIGN REVIEW TO ALLOW THE PHASED DEVELOPMENT OF AN ASSISTED LIVING FACILITY AND COMMERCIAL CENTER AS REPRESENTED IN THE PLANNING COMMISSION AGENDA REPORT AND ATTACHMENTS DATED APRIL 10, 2019 (660 TANK FARM ROAD, 3985 BROAD STREET; EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH- 1486-2018) WHEREAS, the Planning Commission of the City of San Luis Obispo conducted a public hearing in the Council Chamber of City Hall, 990 Palm Street, San Luis Obispo, California, on April 10, 2019, for the purpose of considering an Initial Study-Mitigated Negative Declaration of environmental impacts, Airport Area Specific Plan Amendments, General Plan Amendment and Rezone, Vesting Tentative Tract Map, Architectural Review, and Creek setback exception for the property located at 660 Tank Farm Road and 3985 Broad Street to consider a recommendation to the City Council for a phased project with an assisted living facility and commercial center; and WHEREAS, on June 13, 2018 the Planning Commission of the City of San Luis Obispo conducted a conceptual policy review of the proposed project; and WHEREAS, on October 15, 2018, the Architectural Review Commission of the City of San Luis Obispo reviewed the project for consistency with the with Community Design Guidelines and Airport Area Specific Plan Community Design Standards; and WHEREAS, notices of said public hearing were made at the time and in the manner required by law; and WHEREAS, the Planning Commission has duly considered all evidence, including the testimony of the applicant, interested parties, and the evaluation and recommendations by staff, presented at said hearing. NOW, THEREFORE, BE IT RESOLVED, by the Planning Commission of the City of San Luis Obispo as follows: SECTION 1. Findings. The Planning Commission does hereby recommend the City Council approve the proposed project (SPEC-1482-2018, SBVD-1483-2018 (VTTM #3115), ARCH-1486-2018) that includes a Specific Plan Amendment, General Plan Amendment and Rezone, Vesting Tentative Tract Map, and Architectural Review to allow a phased project consisting of: (7) parcels with up to 49,269 square feet of commercial development and up to Attachment 1 Packet Page 22 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 2 133,656 square feet of assisted living facility including 139 living units and support services based on the following findings: General Plan Amendment, Airport Area Specific Plan Amendment, and Rezone Findings: 1. The proposed amendments to the General Plan, including the rezone, and Airport Area Specific Plan land use amendments as shown in Exhibit A bring the parcels included in the project into consistency with existing zoning of the subject parcel which was rezoned to Community-Commercial with Special Focus Overlay (C-C-SF) when the 2014 Land Use and Circulation Element update was adopted. 2. The proposed project is consistent with policy objectives of the Broad Street and Tank Farm Road Special Focus area since it provides a mix of uses with a strong commercial presence at the intersection. 3. The AASP as amended is consistent with policy direction for the area included in the General Plan and in particular the following General Plan policies: a. LUE Policies 2.2.4 and 2.2.5 provide for neighborhood connections in new projects, both internally and externally so as to integrate new projects into the neighborhoods in which they are proposed, as well as take advantage of opportunities for locating new development close to major employers, retailing and multi -modal transportation facilities; b. LUE Policies 2.3.1, 2.3.6 and 2.3.9, which promote quality neighborhoods and infill development, because the project is located within walking distance to MindBody Headquarters, SESLOC, other nearby employers as well as retail uses and other retail and personal services; c. LUE Policy 3.4.1 encourages mixed-use projects in Community-Commercial districts to provide support services near retailing and office facilities; d. LUE Policy 8.13 establishes the “Special Focus” Area #12 at the subject site to facilitate improvements to bicyclist and pedestrian facilities in the project area, and by integrating uses within the larger established Tank Farm-Broad Street neighborhood reduce vehicle trips and provide additional employment and retailing opportunities to this part of town; and e. The AASP as amended is also consistent with all other applicable General Plan policies, as described and analyzed in the April 10, 2019 staff report to the Planning Commission for this project. 4. On September 19, 2018, The County of San Luis Obispo Airport Land Use Commission found the proposed project to be consistent with the Airport Land Use Plan under authority of Section 2.7 of the ALUP. Attachment 1 Packet Page 23 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 3 5. Amendments as proposed to the AASP will not be detrimental to the surrounding area or cause a decline in quality of life for residents, employees and others in the project vicinity since the project has been reviewed and conditioned by City Departments for conformance with area plans, standards, policies, and regulations applicable to the site. Vesting Tentative Tract Map, and Architectural Review findings: 1. The site is physically suitable for the type and density of development proposed, and as otherwise allowed in the Community-Commercial with Special Focus Overlay (C -C- SF) and Conservation and Open Space Overlay (C/OS) zoning districts. 2. As conditioned, the design of the Vesting Tentative Tract Map is consistent with the General Plan because the proposed subdivision respects existing site constraints, will incrementally add to the City’s commercial and adult/senior care inventory, results in parcels that meet prescribed density standards, and will be consistent with the development standards of the Airport Area Specific Plan (AASP). 3. The design of the vesting tentative tract map and the proposed improvements as designed and conditioned herein are not likely to cause serious health problems, substantial environmental damage or substantially and unavoidably injure fish or wildlife or their habitat. 4. The tentative map, as conditioned, will comply with all environmental mitigation measures prescribed herein, and therefore is consistent with the California Environmental Quality Act, and the Initial Study-Mitigated Negative Declaration (IS-MND). 5. The developments mix of uses provides greater public benefits than a single-use development of the site because it provides both a mix of commercial uses and includes an assisted living facility not otherwise available in the immediate area, it is located along a major transit, bike, and pedestrian corridor, and is in close proximity to workplaces and services. 6. The proposed parking reduction for the Special Focus Area #12 is consistent with shared- parking projects within the City and based on the design of the center with separate commercial buildings on separate parcels with shared access, the anticipated mix of uses will not result in significant or sustained parking deficiencies. 7. The proposed design exception to allow 11’ travel lanes on Tank Farm Road respond to existing constraints and are supported by the Public Works Transportation Division since the minor exception will continue to permit reconfiguration of travel lanes to maximize safe vehicle movements through the area in a manner consistent with the Circulation Element. Attachment 1 Packet Page 24 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 4 8. The proposed creek setback exception will permit an appropriate buffer to be established along the area of the creek-way, will account for the irregular configuration of the subject property in this area, includes creek habitat restoration, and will not result in a reduction of open space along this section of Orcutt Creek that would otherwise compromise habitat protection in the area and is consistent with the policies of the Conservation and Open Space Elements of the General Plan. SECTION 2. Environmental Review. Based upon all evidence, the Planning Commission recommends the City Council adopt the Initial Study-Mitigated Negative Declaration (IS-MND), and adopts the following CEQA Findings in support of all entitlements related to the 660 Tank Farm Road / 3985 Broad Street Mixed-Use project: 1. The Northwest Corner Mixed-Use Project Initial Study-Mitigated Negative Declaration (IS-MND) was prepared in accordance with the California Environmental Quality Act (CEQA) and the State CEQA Guidelines, adequately addressing impacts associated with the proposed amendments to the Airport Area Specific Plan and proposed project; and 2. All potentially significant effects were analyzed adequately in the referenced IS -MND, subject to the following mitigation measures being incorporated into the project and the mitigation monitoring program: AIR QUALITY MITIGATION MEASURES AQ-1 Standard Control Measures for Construction Equipment The following standard air quality mitigation measures shall be implemented during the site preparation and grading phases of construction at the project site: • Maintain all construction equipment in proper tune according to manufacturer’s specifications; • Fuel all off-road and portable diesel-powered equipment with CARB-certified motor vehicle diesel fuel (non-taxed version suitable for use off-road); • Comply with the State Off-Road Regulation; • Use on-road heavy-duty trucks that meet the CARB’s 2007 or cleaner certification standard for on-road heavy-duty diesel engines, and comply with the State On-Road Regulation; • Construction or trucking companies with fleets that do not have engines in their fleet that meet the engine standards identified in the above two measures (e.g. captive or NOX exempt area fleets) may be eligible by proving alternative compliance; • All on and off-road diesel equipment shall not idle for more than 5 minutes. Signs shall be posted in the designated queuing areas and or job sites to remind drivers and operators of the 5-minute idling limit; • Diesel idling within 500 feet of sensitive receptors shall not be not permitted;1 1 SLOAPCD recommends that diesel idling and staging/queuing areas be prohibited within 1,000 feet of sensitive receptors. However, these restrictions would be infeasible for the proposed project because the project site is approximately 850 feet in length, and the nearest sensitive receptors would be the planned residential units located on the parcel immediately adjacent to the project site’s western boundary (650 Tank Farm Road). Therefore, the diesel idling and staging/queuing area restrictions has been reduced to 500 feet. Attachment 1 Packet Page 25 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 5 • Staging and queuing areas shall not be located within 500 feet of sensitive receptors;6 • Equipment shall be electrified when feasible; • Gasoline-powered equipment shall be substituted in place of diesel-powered equipment, where feasible; and • Alternatively-fueled construction equipment shall be used on-site where feasible, such as compressed natural gas, liquefied natural gas, propane or biodiesel. AQ-2 Best Available Control Technology. Diesel construction equipment used during the site preparation and grading phases shall be equipped with CARB Tier 3 or Tier 4 certified off-road engines and 2010 on-road compliant engines. • AQ-1 through AQ-2 Monitoring Program: These conditions shall be noted on all project grading and building plans. The Building Inspector and Public Works Inspectors shall conduct field monitoring. BIOLOGICAL RESOURCES MITIGATION BIO-1 Vegetation removal and initial site disturbance for any project elements shall be conducted between September 1st and January 31st outside of the nesting season for birds. If vegetation removal is planned for the bird nesting season (February 1st to August 31st), then preconstruction nesting bird surveys shall be required to determine if any active nests would be impacted by project construction. If no active nests are found, then no further mitigation shall be required. If any active nests are found that would be impacted by construction, then the nest sites shall be avoided with the establishment of a non-disturbance buffer zone around active nests as determined by a qualified biologist. Nest sites shall be avoided and protected with the non-disturbance buffer zone until the adults and young of the year are no longer reliant on the nest site for survival as determined by a qualified biologist. As such, avoiding disturbance or take of an active nest would reduce potential impacts on nesting birds to a less-than- significant level. BIO-2 The applicant shall obtain Clean Water Act (CWA) regulatory compliance in the form of a permit from the Corps or written documentation from the Corps that no permit would be required for the proposed road crossing. Should a permit be required, the applicant shall implement all the terms and conditions of the permit to the satisfaction of the Corps. Corps permits and authorizations require applicants to demonstrate that the proposed project has been designed and will be implemented in a manner that avoids and minimizes impacts on aquatic resources to the extent practicable. Compliance with Corps permitting would also include obtaining and CWA 401 Water Quality Certification from the Regional Water Quality Control Board (RWQCB). In addition, the Corps and RWQCB may require compensatory mitigation for unavoidable permanent impacts on waters of the U.S./State to achieve the goal of a no net loss of wetland values and functions. As such, with implementation of the 3:1 ratio of creek enhancement mitigation plantings and regulatory compliance would reduce potential impacts on waters of the U.S. to a less-than-significant level. BIO-3 The applicant shall obtain compliance with Section 1602 of the California Fish and Game Code (Streambed Alteration Agreements) in the form of a completed Streambed Alteration Agreement or written documentation from the CDFW that no agreement would be required for the proposed road crossing. Should an agreement be required, the property owners shall implement all the terms and conditions of the agreement to the Attachment 1 Packet Page 26 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 6 satisfaction of the CDFG. The CDFG Streambed Alteration Agreement process encourages applicants to demonstrate that the proposed project has been designed and will be implemented in a manner that avoids and minimizes impacts in the stream zone. In addition, CDFG may require compensatory mitigation for unavoidable permanent impacts on waters of the State. As such, with implementation of the 3:1 ratio of creek enhancement mitigation plantings and regulatory compliance would reduce potential impacts on waters of the U.S. to a less-than-significant level. • B-1 through B-3 Monitoring Program: Prior to issuance of any grading or building permits, Community Development Department staff will verify that necessary permitting and certification requirements have been met and that all improvement plans, landscaping plans and/or relevant construction permits include the required measures for mitigation plantings, creek enhancement, and any compensatory mitigation measures for impacts to Waters of the U.S. as required by the Corps of Engineers and RWQCB. CULTURAL RESOURCES MITIGATION CR-1 Halt Work Order for Discovery of Previously Unidentified Cultural Resources. In the event that historical or archaeological remains are discovered during earth disturbing activities associated with the project, an immediate halt work order shall be issued, and the Community Development Director shall be notified. A qualified archaeologist shall conduct an assessment of the resources and formulate proper mitigation measures, if necessary. After the find has been appropriately mitigated, work in the area may resume. A Chumash representative shall monitor any mitigation excavation associated with Native American materials. CR-2 Halt Work Order for Discovery of Human Remains. In the event that human remains are exposed during earth disturbing activities associated with the project, an immediate halt work order shall be issued, and the Community Development Director shall be notified. State Health and Safety Code Section 7050.5 requires that no further disturbance of the site or any nearby area reasonably suspected to overlie adjacent human remains shall occur until the County Coroner has made the necessary findings as to origin and disposition pursuant to Public Resources Code Section 5097.98. If the remains are determined to be of Native American descent, the coroner shall notify the Native American Heritage Commission within 24-hours. • CR-1 to CR-2 monitoring program: Community Development Department staff will verify appropriate notes identifying requirements are listed prominently for contractor reference on applicable construction documents which involve significant ground disturbance including grading or trenching. NOISE MITIGATION Attachment 1 Packet Page 27 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 7 N-1 Sound Wall and or Special Building Considerations South Elevation Assisted Living Facility. At the time of submittal of construction plans for the assisted living facility, an acoustical engineering report/analysis will be submitted detailing construction techniques for noise mitigation to ensure interior habitable spaces facing south do not exceed annual CNEL = 45 dBA. The mitigation will most likely be wall, window and door assemblies, or a combination of these, with an enhanced Sound Transmission Class rating to resist the street noise coming from Tank Farm Road. • N-1 monitoring program: Prior to issuance of building permits, the acoustical engineering report will be required by Community Development Department staff to verify interior noise levels will not exceed 45 dBA, and any requirements will be clearly noted on all plans for building construction. TRANSPORTATION MITIGATION MEASURES T-1 Tank Farm Road from Broad through Project Site to Mindbody intersection. Provide a second westbound through lane on Tank Farm Road consistent with the cross section in the Airport Area Specific Plan. Provide two westbound lanes, bike lanes, and sidewalks consistent with the parkway arterial designation in the Airport Area Specific Plan. T-2 Tank Farm Road from Old Windmill Lane to Santa Fe Road. The project shall make a fair share contribution of 0.62 percent of the cost of widening Tank Farm Road to four lanes between Santa Fe Road and Old Windmill Lane T-3 Broad Street/Industrial Way. The project shall make a fair share contribution towards converting the east and west approaches from split phasing to permissive phasing and restriping both east and west legs of the intersection to provide dedicated left turn lanes and shared through/right turn lanes. T-4 Fair Share Contributions. The project applicant shall make fair share contributions towards the following improvements through payment of Citywide Traffic Impact Fees: • Tank Farm Road/Higuera Street: Install a second southbound left turn lane. • Tank Farm Road/Santa Fe Road: Install a multi-lane roundabout. • Broad Street/Tank Farm Road: Install a dedicated northbound right turn lane, convert the westbound right turn lane to a shared through/right lane, and establish time- of-day timing plans. • MM T-2, T-3, and T-4 monitoring program: The Transportation Division of Public Works, and the Community Development Department will require that fair share contributions are paid prior to issuance of building permits. Attachment 1 Packet Page 28 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 8 • MM T-1 monitoring program: The Transportation Division of Public Works, and the Community Development Department will require that public improvements are completed prior to occupancy. SECTION 3. Action. The Planning Commission does hereby recommend the City Council approve the proposed project (SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018) that includes a Specific Plan Amendment, General Plan Amendment and Rezone, Tentative Tract Map, Creek setback exception, and Architectural review to allow a mixed-use project covering seven (7) parcels with up to 49,269 square feet of commercial development and up to 133,656 square feet of assisted living facility including 139 living units and support services. The Planning Commission’s recommendation includes Exhibits A & B to this resolution depicting the General Plan Amendment and rezone at 660 Tank Farm Road, Airport Area Specific Plan Amendment (Exhibit A), and associated text amendments to the Airport Area Specific Plan (Exhibit B). Planning Division – Community Development Department 1. The applicant shall defend, indemnify and hold harmless the City and/or its agents, officers and employees from any claim, action or proceeding against the City and/or its agents, officers or employees to attack, set aside, void or annul, the approval by the City of this project, and all actions relating thereto, including but not limited to environmental review (“Indemnified Claims”). The City shall promptly notify the applicant of any Indemnified Claim upon being presented with the Indemnified Claim and the City shall fully cooperate in the defense against an Indemnified Claim. 2. Plans submitted for a building permit shall call out the colors and materials of all proposed building surfaces and other improvements. Colors and materials shall be consistent with the final approved color and material board. 3. The locations of all exterior lighting, including lighting on the structure, bollard style landscaping or path lighting, shall be included in plans submitted for a building permit. All wall-mounted lighting fixtures shall be clearly called out on building elevations included as part of working drawings. All wall-mounted lighting shall complement building architecture. The lighting schedule for the building shall include a graphic representation of the proposed lighting fixtures and cut-sheets on the submitted building plans. The selected fixture(s) shall be shielded to ensure that light is directed downward consistent with the requirements of the City’s Night Sky Preservation standards contained in Chapter 17.23 of the Zoning Regulations. 4. Mechanical and electrical equipment shall be located internally to the building. With submittal of working drawings, the applicant shall include sectional views of the building, which clearly show the sizes of any proposed condensers and other mechanical equipment. If any condensers or other mechanical equipment is to be placed on the roof, plans submitted for a building permit shall confirm that parapets and other roof features will provide adequate screening. A line-of-sight diagram may be required to confirm that proposed screening will Attachment 1 Packet Page 29 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 9 be adequate. This condition applies to both initial project construction and later building modifications and improvements. 5. A final landscaping plan, including irrigation details and plans, shall be submitted to the Community Development Department along with working drawings. The legend for the landscaping plan shall include the sizes and species of all groundcovers, shrubs, and trees with corresponding symbols for each plant material showing their specific locations on plans. 6. The location of any required backflow preventer and double-check assembly shall be shown on all site plans submitted for a building permit, including the landscaping plan. Construction plans shall also include a scaled diagram of the equipment proposed. Where possible, as determined by the Utilities Director, equipment shall be located inside the building within 20 feet of the front property line. Where this is not possible, as determined by the Utilities Director, the backflow preventer and double-check assembly shall be located in the street yard and screened using a combination of paint color, landscaping and, if deemed appropriate by the Community Development Director, a low wall. The size and configuration of such equipment shall be subject to review and approval by the Utilities and Community Development Directors. 7. A final sign program for the Commercial site shall be approved by the Director of Community Development prior to issuance of building permits for that phase of the project. The sign program shall include information on the sizes, locations, colors, materials, types, and illumination of all signage. Project signs shall be designed to be compatible with the architecture of proposed buildings and complement the site’s setting. 8. Inclusionary Housing. Prior to issuance of building permits, inclusionary in-lieu fees of 5% of building evaluation shall be paid. 9. The following use standards and conditions reflect requirements established under the San Luis Obispo County Airport Land Use Commission’s (ALUC) determination of consistency (9-19-2018) and shall be complied with as follows: a. The Project submitted to the County under Referral Letter dated July 25, 2018 shall be conditioned by the City to be consistent with said referral, and will not be changed without the input of the ALUC; b. Airport Area Specific Plan Amendments as provided herein are limited to the subject property; c. Non-residential density for the site within the S-1c Safety Area would be limited to a maximum 120 persons/acre; d. Maximum building heights would be 35’; e. Interior noise standards of the Airport Land Use Plan (ALUP) would be met inside the assisted living facility; f. No improvements would constitute a navigation hazard as defined by the ALUP; g. Uses that would potentially interfere with takeoffs, landings and maneuvering of aircraft would be prohibited; h. Avigation easements would be required for the site; and, Attachment 1 Packet Page 30 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 10 i. Disclosures would be provided to potential buyers and tenants regarding airport operations. Engineering Division – Public Works/Community Development Department 10. Any easements including but not limited to provisions for all public and private utilities, access, grading, drainage, open space, slope banks, construction, public and private streets, pedestrian and bicycle facilities, common driveways, and maintenance of the same shall be shown on the final map and/or shall be recorded separately prior map recordation. Said easements may be provided for in part or in total as blanket easements. 11. The final map and improvement plans shall show the extent of all existing and proposed on- site and off-site offers of dedication. Subdivision improvement plans and or preliminary designs may be required for any deferred improvements so that dedication limits can be established. These improvements may include but are not limited to road construction and widening, grading and drainage improvements, utility easements, bridges, bike bridges, transit stops, bikeways, pedestrian paths, and signalized intersections. 12. The map and/or improvement plans shall show and label the separate access easements to serve the Sesloc property to the north and the redevelopment project to the west known as 650 Tank Farm Road. The map and plans shall show and label the proposed private sewer main easement to serve the proposed Sesloc development to the north. Separate easement agreements shall be prepared and finalized by the developer. 13. The subdivider shall dedicate a 10’ wide street tree easement and 15’ wide public utility easement (P.U.E.) across the Broad Street and Tank Farm Road frontages of each lot. Said easements shall be adjacent to and contiguous with all public right-of-way lines bordering each lot. 14. Access rights shall be dedicated to the City along the Broad Street and Tank Farm Road frontages except at approved driveway locations. Said dedications shall be shown and labeled on the final map. 15. The developer shall include any other out-of-tract offers of dedication related to the need for public utility extensions related to orderly development of the AASP that are not otherwise located within a public street. 16. All private improvements shall be owned and maintained by the individual property owners and/or a Commercial Owner’s Association as applicable. Private improvements include but are not limited to streets, drive aisles, parking lot improvements, sidewalks, private pedestrian/bike paths, private sewer mains/laterals, water services, fire services, reclaimed water services, drainage systems, detention basin(s), site lighting, landscape, landscape Attachment 1 Packet Page 31 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 11 irrigation, and common areas. 17. A notice of requirements or other agreement acceptable to the City of San Luis Obispo may need to be recorded in conjunction with the Final Map to clarify development restrictions, fee payments, conditions of development, and references to any pertinent conditions of approval related to this map and/or off-site requirements. 18. Off-site improvements, easements and/or dedications may be required to facilitate through street access and public water, recycled water and sewer main extensions beyond the tract boundary and in accordance with the AASP. 19. Unless specifically approved by the City, all public and private subdivision improvements shall be approved prior to map recordation and/or building permit issuance, whichever occurs first. Subdivision sureties shall be provided for all subdivision improvements if the map will record prior to completion of the improvements. 20. Unless phased or interim improvements are approved by the City, all pertinent public and private subdivision improvements shall be completed prior to building occupancy. 21. The subdivider shall remove the off-site right-in/right-out turning island serving the Sesloc property within the Broad Street right-of-way. This access will be replaced by a similar on- site access to the perimeter roadway along the northern edge of the site adjoining the SESLOC property. The new access driveway off of Broad Street shall restrict access to right-in/right-out/left-in only. The developer shall provide written notice to Sesloc on the proposed construction schedule and timing related to the off-site public and private improvements related to the abandonment of the Sesloc driveway. A copy of said notification shall be provided to the City. 22. A separate building permit/parking lot permit shall be processed for the proposed private Sesloc on-site improvements required to accommodate the closure of the southerly Sesloc parking lot access. The driveway shall not be closed until a secondary access is provided unless otherwise approved by Sesloc and the City. 23. With respect to any off-site improvements, prior to filing of the Final Map, the subdivider shall either: a. Clearly demonstrate their right to construct the improvements by showing access to, title or interest in the property in a form acceptable to the City Engineer; or, b. Demonstrate, in writing, that the subdivider has exhausted all reasonable efforts to acquire interest to the subject property and request that the City assist in acquiring the propert y required for the construction of such improvements and exercise its power of eminent domain in accordance with Government Code Section 66462 .5 to do so, if Attachment 1 Packet Page 32 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 12 necessary. Subdivider shall also enter into an agreement with the City to pay all costs of such acquisition including, but not limited to, all costs associated with condemnation. Said agreement shall be in a form acceptable to the City Engineer and the City Attorney. If condemnation proceedings are required, the subdivider shall submit, in a form acceptable to the City Engineer, the following documents regarding the property to be acquired: i. Property legal description and sketch stamped and signed by a Licensed Land Surveyor or Civil Engineer authorized to practice land surveying in the State of California; ii. Preliminary title report including chain of title and litigation guarantee; iii. Appraisal of the property by a City approved appraiser. In the course of obtaining such appraisal, the property owner(s) must be given an opportunity to accompany the appraiser during any inspection of the property or acknowledge in writing that they knowingly waived the right to do so; iv. Copies of all written correspondence with off-site property owners including purchase summary of formal offers and counter offers to purchase at the appraised price. v. Prior to submittal of the aforementioned documents for City Engineer approval, the Subdivider shall deposit with the City all or a portion of the anticipated costs, as determined by the City Attorney, of the condemnation proceedings. The City does not and cannot guarantee that the necessary property rights can be acquired or will, in fact, be acquired. All necessary procedures of law would apply and would have to be followed. 24. All public streets shall conform to City Engineering Standards and AASP including curb, gutter, and sidewalk, driveway approaches, and curb ramps as approved by the City Engineer. Where conflicts occur between the City Engineering Standards and concepts identified in the AASP and/or this project approval, a final determination on design shall be provided by the City Engineer. 25. Final roadway alignment shall be consistent with the AASP, Bike Plan, and City Engineering Standards except where the applicant has requested and been granted a formal design exception. 26. The development plans shall be revised to include the circulation changes shown at the project interface with the Sesloc access driveway to the north as shown on Conceptual Site Plan sheet SP-1 dated 2/5/19 and Bethel Engineering reference plan sheet 1 of 1 dated 1/23/19. The final orientation of the through street, stop controlled drive aisle, pedestrian access, and bike connectivity shall be approved to the satisfaction of the City. Attachment 1 Packet Page 33 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 13 27. The improvement plans shall include all final line-of-sight analysis at applicable intersections to the satisfaction of the Public Works Department. Fence heights and plantings in the areas of control shall be reviewed in conjunction with the analysis. A separate recorded declaration, covenant, agreement or Notice of Requirements for private property owner maintenance of sight lines may be required. 28. Any jurisdictional permits from the Army Corp, Fish and Wildlife, or Regional Water Quality Control Board required for the drainage, site improvements, street and road improvements shall be issued prior to plan approval and/or commencing with work within the respective waterways. 29. All mitigation measures (MM) specific to Transportation requirements shall be provided as detailed under this Resolution to the satisfaction of the City Engineer. 30. Access rights for the development at 650 Tank Farm Road shall be dedicated prior to or concurrent with the recordation of the final map. Improvements for access would be completed by the development at 650 Tank farm Road under the conditions of their permits. A shared maintenance program for this access may be prepared between the parties and will be included with disclosures to prospective tenants and buyers as provided in these conditions (See COA 57). 31. The subdivider shall install public street lighting and all associated facilities including but not limited to conduits, sidewalk vaults, fusing, wiring and luminaires along all public streets and intersections per City Engineering Standards. 32. Private site lighting shall be provided per City Engineering Standards. Unless otherwise waived by the City, the through access roadway/bikeway from the northerly tract boundary to the signal at Tank Farm Road shall include street/pathway lighting per City Engineering Standards and the City’s Bike Plan. 33. Improvement plans for the entire subdivision, including any off-site improvements shall be approved to the satisfaction of the Public Works Department, Utilities Department, and Fire Department prior to map recordation. 34. The improvement plans shall clearly show all existing structures, site improvements, utilities, water wells, septic tanks, leach fields, gas and wire services, etc. The plan shall include the proposed disposition of the improvements and any proposed phasing of the removal and demolition. All structures and utilities affected by the proposed lot lines shall be removed and receive final inspection approvals prior to map recordation. 35. The improvement plan submittal shall include a complete construction phasing plan in accordance with the conditions of approval, City codes, and standards. A truck circulation Attachment 1 Packet Page 34 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 14 plan and construction management and staging plan shall be included with the improvement plan submittal. General truck routes shall be submitted for review and acceptance by the City. The engineer of record shall provide a summary of the extent of cut and fill with estimates on the yards of import and export material. The summary shall include rough grading, utility trench construction, road construction, AC paving, concrete delivery, and vertical construction loading estimates on the existing public roadways. The developer shall either; 1) complete roadway deflection testing before and after construction to the satisfaction of the City Engineer and shall complete repairs to the pre-construction condition, or 2) shall pay a roadway maintenance fee in accordance with City Engineering Standards and guidelines, or 3) shall propose a pavement repair/replacement program to the satisfaction of the City Engineer prior to acceptance of the subdivision improvements. 36. Separate utilities, including water, sewer, gas, electricity, telephone, and cable TV shall be served to each lot to the satisfaction of the Public Works Department and serving utility companies. All public and private sewer mains shall be shown on the public improvement plans and shall be constructed per City Engineering Standards unless a waiver or alternate standard is otherwise approved by the City. The plans shall clearly delineate and distinguish the difference between public and private improvements. 37. City recycled water or another non-potable water source, shall be used for construction water (dust control, soil compaction, etc.). An annual Construction Water Permit is available from the City’s Utilities Department. Recycled water is readily available near the intersection of Tank Farm Road and Orcutt Road. 38. Final grades and alignments of all public and/or private water, sewer and storm drains shall be approved to the satisfaction of the Public Works Director and Utilities Department. The final location, configuration, and sizing of service laterals and meters shall be approved in conjunction with the review of the building plans, fire sprinkler plans, and/or public improvement plans. 39. The improvement plans shall show the location of all domestic and landscape water meters. The plan shall include service lateral sizes and meter sizes. Sizing calculations may be required to justify service and meter sizing. Water impact fees related to the irrigation water meter(s) shall be paid prior to approval of the subdivision improvement plans for each pertinent map and/or construction phase. 40. The development of the on-site utility plan shall include a sewer study to confirm the minimum design depth of the private sewer main to accommodate a creek crossing and gravity flow from the proposed Sesloc office expansion project. 41. Unless otherwise approved by the City, sewer laterals and/or private mains shall connect to the public sewer main located within Tank Farm Road. If approved for connection in Broad Attachment 1 Packet Page 35 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 15 Street, a comprehensive plan based on the field confirmation of all existing public and private utility depths shall be completed to confirm that a gravity sewer can be achieved with gradients and utility clearances per City Engineering Standards. Transportation Division - Public Works Department 42. The project shall pay all required transportation impact fees, including required County 227 Impact Fees, and fair share contributions as indicated in the traffic impact study, dated Nov. 11, 2018, and project environmental documents before building permits are issued. 43. The following required public improvements shall be completed by the property owner prior to occupancy: a. Re-stripe southbound approach at Broad Street/Tank Farm intersection to provide two (2) left turn lanes, to the satisfaction of the Public Works Director. Improvements include any required modifications to traffic signal detection, phasing operation and timings to accommodate additional turn lane. b. Locate curb and gutter and pave out Tank Farm Road to final Airport Area Specific Plan cross section across entire property frontage. Stripe roadway to the satisfaction of the Public Works Director. c. Abandon SESLOC driveway to the north of the project site and reconstruct sidewalk, parkway and gutter to City Standards. d. The median on Tank Farm along the project frontage shall be reconstructed in concrete, to the satisfaction of the Public Works Director. e. Complete median design / access controls for right-in / right-out / left-in access at the north project driveway on Broad Street, to the satisfaction of the Public Works Director. f. Complete traffic signal improvements to the Tank Farm / Mindbody signal to the satisfaction of the Public Works Director. This includes all required poles, signal heads, cables, cabinet equipment, battery backups and all other necessary equipment for the traffic signal to function in its intended purpose, per Caltrans and City of San Luis Obispo Standard Specifications. 44. Project shall grant a public access easement along the entire access roadway (connection between Mindbody Signal and SESLOC property) to the west of the project site. Utilities Department 45. The proposed utility infrastructure shall comply with the latest engineering design standards effective at the time the building permit is obtained, and shall have reasonable alignments needed for maintenance of public infrastructure. 46. Revisions to the city owned fiber optic cable located along the east boundary of the project, that may result from the proposed land use modifications, shall be adjusted or re- constructed to the satisfaction of the Utilities Director. Attachment 1 Packet Page 36 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 16 47. The proposed project is within an area subject to shallow ground water. Heat-fused HDPE pipe shall be used for the proposed private and public sewer collection system to prevent groundwater infiltration. 48. If commercial uses in the project include food preparation, provisions for grease interceptors and FOG (fats, oils, and grease) storage within solid waste enclosure(s) shall be provided with the design. These types of facilities shall also provide an area inside to wash floor mats, equipment, and trash cans. 49. The site is within the City’s Water Reuse Master Plan area and landscape irrigation for the project shall utilize recycled water from the existing service that was stubbed to the property. The irrigation system shall be designed and operated as described consistent with recycled water standards in the City’s Procedures for Recycled Water Use, including the requirement that sites utilizing recycled water require backflow protection on all potable service connections. The irrigation plans shall be submitted to the Building Department for review during the City’s building permit review process. Frontage improvements must include approximately 950-feet of a new 8” recycled water main with new recycled water services to the project. The alignment of the recycled water mains shall follow the engineering design standards and shall be designed to the satisfaction of the Utilities Engineer. 50. The project’s commercial and residential uses shall be metered separately. 51. Public sewer and water pipe infrastructure shall not be extended into private access road, but public water meters can be installed for each parcel with a dedicated access easement, and is to the satisfaction of the Utilities Engineer. 52. Irrigation systems using recycled water shall be designed and operated as described consistent with the City’s Procedures for Recycled Water Use, including the requirement that sites utilizing recycled water require backflow protection on all potable service connections in accordance with the Engineering Design Standards. Three sets of irrigation plans shall be submitted for review during the City’s improvement plan and/or building permit review process. 53. Water flow rates and flow velocities shall comply with the minimum requirements of the 2016 Potable Water Distribution System Operations Master Plan. 54. Final grades and alignments of all public and/or private water, recycled water, and sewer shall be approved to the satisfaction of the Utilities Department. The final location, configuration, and sizing of on-site service laterals and meters shall be approved by the Utilities Director in conjunction with the review of the building plans, fire sprinkler plans, and/or public improvement plans. Code Requirements: 55. Potable water shall not be used for major construction activities, such as grading and dust control as required under Prohibited Water Uses; Chapter 13.07.070.C of the City’s Municipal Code. Recycled water is available through the City’s Construction Water Permit Attachment 1 Packet Page 37 660 TANK FARM ROAD, 3985 BROAD STREET EID-1484-2018, SPEC-1482-2018, SBVD-1483-2018, ARCH-1486-2018 Page 17 program. 56.Projects generating more than two cubic yards of total waste shall comply with AB 1826, and local waste management ordinance to reduce greenhouse gas emissions. 57.Trash enclosure and refuse bins shall be sized to provide a reasonable level of service per the requirements of the San Luis Garbage Company. 58.During Building Permit Review, the development of the plan shall be coordinated with San Luis Garbage. The plan must be submitted for approval by the City's Utilities Engineer prior to issuance of the project’s Building Permit. Upon motion of _______________________, seconded by _______________________, and on the following roll call vote: AYES: NOES: ABSENT: The foregoing resolution was adopted this 10th day of April 2019. Attachment 1 ____________________________________ Xzandrea Fowler, Secretary Planning Commission Packet Page 38 Specific Plan: BP-SP to CC-SP-SF General Plan: Business Park to Community Commercial Zoning: BP-SP to CC-SF Specific Plan: BP-SP to CC-SP-SF 3985 Broad St 660 TankFarm Rd TANK FAR M BRO AD µ0 100 200 300 400 500 600Feet GP Amendment, RZ, SPA 660 Tank Farm Road and 3985 Broad Street Exhibit AAttachment 1 Packet Page 39 **DRAFT** Airport Area Specific Plan Amendments (SPEC-1482-2018) NWC Broad Street and Tank Farm Road Mixed-use a shopping center & assisted living facility 3985 Broad Street & 660 Tank Farm Road, San Luis Obispo, CA 053-421-003, 053-421-004 20 July 2018; rev. 7 January 2019 I.INTRODUCTION The Broad Street at Tank Farm Road Site is identified as a special focus area in the General Plan within the Airport Area Specific Plan (“AASP”). It is unique, and the only location in the AASP with this particular designation and zoning. Therefore, the proposed amendment utilizes the “Special Areas” section of the AASP Land Use chapter to identify and describe the special focus area; it’s relationship to the General Plan and Specific Plan, and key development standards. Pursuant to the submitted applications for the Mixed-Use development at 3985 Broad Street and 660 Tank Farm Road, the following excerpts from the Airport Area Specific Plan Chapter 4.0- Land Use include the proposed text amendments. Inserted text is bold, blue and underlined. Deleted text is bold, red with strikethrough (strikethrough). II.AIRPORT AREA SPECIFIC PLAN CHAPTER 4.0 LAND USE RELATIONSHIP TO THE GENERAL PLAN [Amend Table 4.2] Community Commercial (Special Focus Area #12) Community Commercial (Special Focus) CC-SF Exhibit B Attachment 1 Packet Page 40 Airport Area Specific Plan Text Amendment SPEC-1482-2018 Oasis Associates, Inc. 20 July 2018; rev. 7 January 2019 2 of 5 SPECIAL AREAS [Insert text at end of section] BROAD STREET AT TANK FARM ROAD SITE The Broad Street at Tank Farm Road Site is identified in the General Plan Land Use Element and Map as a Special Focus Area #121, and is further iterated by a zoning designation of Community Commercial with Special Focus Overlay (C-C-SF).2 Development of this site shall be consistent with the General Plan description “Located at the northwest corner of Broad Street and Tank Farm Road, this approximate 10 acre site will be used as a mixed use site, providing for a mix of uses as described under the Community Commercial and Office designations. The site will provide a strong commercial presence at the intersection. Areas along the creek on the western edge of the site will be appropriately buffered to provide creek protections. Attention to connectivity, safety and comfort of bicycle and pedestrian circulation will be especially important in the development of this corner.” Source: 2014 General Plan Land Use Element- (8.13) Special Focus Area. The intent of the Office zone is to provide for offices and related functions close to medical facilities and the downtown, convenient to public transportation and related government and business services. The Office zone is also intended to provide for the continuation and development of residential uses where they will be compatible with neighboring offices. The Community Commercial zone is intended to provide for a wide range of retail sales and personal services within the context of distinctive, pedestrian-oriented shopping centers that serve customers and clients from all over the City. The development plans and project description for this mixed-use area includes: •A retail shopping center with uses consistent with the Community Commercial and Office zones at the northwest corner of the Tank Farm Road and Broad Street intersection, and a residential assisted living facility located on the western portion of the property. •North-south road connection from the signalized intersection of Tank Farm Road and Mindbody driveway to the drive aisle on SESLOC property to the north, that ultimately connects to Industrial Way. •Enhancement of the creek and riparian habitat areas. Limited encroachment into the creek setback area may be necessary for the north-south road connection. •The development shall comply with the following development standards Standard C-C-SF Standard Maximum Density Pursuant to Airport Land Use Plan Minimum Yards (Setbacks) Building to Broad and Tank Farm street frontage Parking lots to Broad and Tank Farm street frontage 15 feet 10 feet 1 See Land Use Element Map (December 2014) http://www.slocity.org/home/showdocument?id=5857 2 See Zoning Map (January 2015) http://gis.slocity.org/Documents/ZoningMap2015.pdf Exhibit B Attachment 1 Packet Page 41 Airport Area Specific Plan Text Amendment SPEC-1482-2018 Oasis Associates, Inc. 20 July 2018; rev. 7 January 2019 3 of 5 Parking lots to interior property lines and adjacent parcels Building to interior property lines and adjacent parcels None None Maximum Height 35 feet Maximum coverage 75 percent Maximum floor area ratio 2.0 Standard Lot Dimensions See Tentative Tract Map 3115 Minimum Parking Requirements Assisted Living Bank and Credit Union General Market (Grocer) Office Retail Sales and Personal Service Restaurant Uses not listed Accessible, Clean Air, Motorcycle, Bike parking 1 space per every 5 beds (plus 1 space per 2 employees on shift 1 space per 300 SF 1 space per 250 SF 1 space per 500 SF 1 space per 300 SF 1 space per 100 SF of total restaurant area (including any food preparation/ service area) See Zoning Regulation requirements See Zoning Regulation requirements III.“CLEAN” TEXT The following duplication of the proposed text amendment is provided in a “clean” format for review reference and formatting purposes. RELATIONSHIP TO THE GENERAL PLAN Community Commercial (Special Focus Area #12) Community Commercial (Special Focus) CC-SF Exhibit B Attachment 1 Packet Page 42 Airport Area Specific Plan Text Amendment SPEC-1482-2018 Oasis Associates, Inc. 20 July 2018; rev. 7 January 2019 4 of 5 SPECIAL AREAS BROAD STREET AT TANK FARM ROAD SITE The Broad Street at Tank Farm Road Site is identified in the General Plan Land Use Element and Map as a Special Focus Area #123, and is further iterated by a zoning designation of Community Commercial with Special Focus Overlay (C-C-SF).4 Development of this site shall be consistent with the General Plan description “Located at the northwest corner of Broad Street and Tank Farm Road, this approximate 10-acre site will be used as a mixed use site, providing for a mix of uses as described under the Community Commercial and Office designations. The site will provide a strong commercial presence at the intersection. Areas along the creek on the western edge of the site will be appropriately buffered to provide creek protections. Attention to connectivity, safety and comfort of bicycle and pedestrian circulation will be especially important in the development of this corner.” Source: 2014 General Plan Land Use Element- (8.13) Special Focus Area. The intent of the Office zone is to provide for offices and related functions close to medical facilities and the downtown, convenient to public transportation and related government and business services. The Office zone is also intended to provide for the continuation and development of residential uses where they will be compatible with neighboring offices. The Community Commercial zone is intended to provide for a wide range of retail sales and personal services within the context of distinctive, pedestrian-oriented shopping centers that serve customers and clients from all over the City. The development plans and project description for this mixed-use area includes: •A retail shopping center with uses consistent with the Community Commercial and Office zones at the northwest corner of the Tank Farm Road and Broad Street intersection, and a residential assisted living facility located on the western portion of the property. •North-south road connection from the signalized intersection of Tank Farm Road and Mindbody driveway to the drive aisle on SESLOC property to the north, that ultimately connects to Industrial Way. •Enhancement of the creek and riparian habitat areas. Limited encroachment into the creek setback area may be necessary for the north-south road connection. •The development shall comply with the following development standards Standard C-C-SF Standard Maximum Density Pursuant to Airport Land Use Plan Minimum Yards (Setbacks) Building to Broad and Tank Farm street frontage 15 feet 3 See Land Use Element Map (December 2014) http://www.slocity.org/home/showdocument?id=5857 4 See Zoning Map (January 2015) http://gis.slocity.org/Documents/ZoningMap2015.pdf Exhibit B Attachment 1 Packet Page 43 Airport Area Specific Plan Text Amendment SPEC-1482-2018 Oasis Associates, Inc. 20 July 2018; rev. 7 January 2019 5 of 5 Parking lots to Broad and Tank Farm street frontage Parking lots to interior property lines and adjacent parcels Building to interior property lines and adjacent parcels 10 feet None None Maximum Height 35 feet Maximum coverage 75 percent Maximum floor area ratio 2.0 Standard Lot Dimensions See Tentative Tract Map 3115 Minimum Parking Requirements Assisted Living Bank and Credit Union General Market (Grocer) Office Retail Sales and Personal Service Restaurant Uses not listed Accessible, Clean Air, Motorcycle, Bike parking 1 space per every 5 beds (plus 1 space per 2 employees on shift1 space per 300 SF 1 space per 300 SF 1 space per 250 SF 1 space per 500 SF 1 space per 300 SF 1 space per 100 SF of total restaurant area (including any food preparation/ service area) See Zoning Regulation requirements See Zoning Regulation requirements Exhibit B Attachment 1 Packet Page 44 NKT Development LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 1 of 14 Application Supplement NWC Broad Street and Tank Farm Road Mixed-use a shopping center & assisted living facility 3985 Broad Street & 660 Tank Farm Road, San Luis Obispo, CA 053-421-003, 053-421-004 SPEC 1482-2018, SBDV-1483-2018, EID-1484-2018, ARCH-1486-2018 January 8, 20191 I. INTRODUCTION & EXECUTIVE SUMMARY Since 2005, the Business Park zoned subject properties have been included in the City’s Airport Area Specific Plan (AASP). While the land use concepts for the AASP have always been intended to meet multiple City goals, modifications to that vision can change over time. In that context, the Land Use and Circulation Element, updated in December 2014, recognized the need to change the zoning on the two subject parcels to facilitate development based upon changing market trends, while maintaining the essential blueprint for the area’s future. While comprehensively planned for and presented together as a mixed-use project, the two components of the project is distinct. The project proponents, and their respective design team members, are excited to lodge an application for a contemporary shopping center on the northwest corner of Broad Street and Tank Farm Road and an assisted living facility, to be located west of and adjacent to the shopping center on Tank Farm Road. Nicholas Tompkins, the principal of NKT Development LLC, is a seasoned commercial and shopping center developer. To his shopping center credits is the remodel of University Square, San Luis Obispo (completed) and the Enos Ranchos development, Santa Maria (also completed). In addition, NKT has been responsible for multiple commercial buildings in the City – the business park located on the southwest corner of Broad Street and Tank Farm Road, the MindBody campus, and the mixed-use project under construction on the corner of Monterey Street and Santa Rosa, to name a few. Westmont Living, Inc./Westmont Development LP is a senior housing construction and management company that is focused on building value for their constituents: residents, families, and team members. Principals Michael O’Rourke, CEO and Andy Plant, President have been committed to senior housing with a combined tenure of over four decades. They are supported in their efforts by over 700 employees, who operate eleven (11) senior housing communities that includes 1,300 units/beds in California and Oregon. They see their investment in San Luis Obispo to be a natural extension of their vision for “inspired retirement living” ® From an entitlement perspective, the above-mentioned proposals will require the following from the City. • Environmental Review and Determination; • A Vesting Tentative Tract Map 3115; • An amendment to the Airport Area Specific Plan; • Approval of off-site Public Improvement Plans, including a minor design exception for the Tank Farm Road right-of-way; • and, ultimately Building Permits. 1 Previous dated iterations are 20 March 2018, and 27 April 2018 Attachment 2 Packet Page 45 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 2 of 14 II. PROJECT TEAM Overall/Common Team A. Property Owner NKT DEVELOPMENT, LLC c/o Nick Tompkins 684 Higuera Street, Suite B San Luis Obispo, CA 93401 (805)-541-9004 B. Applicant’s Agent OASIS ASSOCIATES, INC. c/o C.M. Florence, AICP 3427 Miguelito Court San Luis Obispo, CA 93401 (805) 541-4509 cmf@oasisassoc.com C. Civil Engineer BETHEL ENGINEERING c/o Lori Speer, PE 2624 Airpark Drive Santa Maria, CA 93455 (805) 934-5767 lori@dbaengineers.com D. Biologist SAGE INSTITUTE, INC. c/o David K. Wolff 1320 Van Beurden, Ste 202-D4 Los Osos, CA 93402 (805) 434-2804 x 102 dwolff@sageii.com Shopping Center Team E. Applicant NKT DEVELOPMENT, LLC c/o Nick Tompkins 684 Higuera Street, Suite B San Luis Obispo, CA 93401 (805)-541-9004 F. Architect McKENTLY MALAK ARCHITECTS c/o Ken McKently, AIA 35 Hugus Alley Ste 200 Pasadena, CA 91103 (626) 583-8348 ken@mckently.com G. Landscape Architect SMP ENVIRONMENTAL DESIGN c/o James L. Burrows 979 Osos Street, Suite B6, San Luis Obispo, CA 93401 (805) 439-3209 jburrows@smpinc.net Assisted Living Center H. Applicant WESTMONT DEVELOPMENT, LP c/o Michael O’Rourke 7660 Fay Avenue, Ste M La Jolla, CA92037 (415) 317-9969 I. Architect LENITY ARCHITECTURE c/o Aaron Clark, AIA 3150 Kettle Court SE Salem, OR 97301 (503) 399-1090 aaronc@lenityarchitecture.com J. Landscape Architect LENITY ARCHITECTURE c/o Brian Lind 3150 Kettle Court SE Salem, OR 97301 (503) 399-1090 brianl@lenityarchitecture.com Attachment 2 Packet Page 46 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 3 of 14 III. PROJECT CONTEXT- REGULATORY AND PHYSICAL To frame the projects within the context of the City’s regulatory and physical framework, the following describes the regulatory “inspiration” for the projects and the surrounding zoning and land uses. A. Land Use Element Update The update to the General Plan – Land Use and Circulation Element (LUCE) included a number of “special focus” areas within the City. The subject properties are included in the LUCE programs §8.13 Broad Street at Tank Farm Road Site. Specifically, the section reads, Located at the northwest corner of Broad Street and Tank Farm Road, this approximate 10- acre site will be used as a mixed-use site, providing for a mix of uses as described under the Community Commercial and Office designations. The site will provide a strong commercial presence at the intersection. Areas along the creek on the western edge of the site will be appropriately buffered to provide creek protections. Attention to connectivity, safety and comfort of bicycle and pedestrian circulation will be especially important in the development of this corner. In concert with the City, the property owner participated in the LUCE update process with the resultant land use category change and vision for development. While part of the General Plan, the noted modifications will now need to be embedded into the Airport Area Specific Plan (AASP)as part of this application. A draft of the proposed AASP text amendment is provided as an attachment. B. Surrounding Zoning/Uses The properties, located within Airport Area Specific Plan represent a mixture of uses that speak directly to the City’s blueprint for a forward-thinking, community driven, and economically sustainable development, as noted by the referenced zoning/uses. LAND USE CATEGORY EXISTING USES /TENANT North . – Business Park (BP-SP) ............................ SESLOC Federal Credit Union South – Business Park (BP-SP) ............................ Mindbody, Edna Valley Market & Gas Station East – Community Commercial (C-C) .............. Marigold Shopping Center West – Medium Density Residential (R-2-SP) ... Hidden Hills Mobilodge Note: “SP” denotes the property is within a Specific Plan area C. Existing Conditions The two-parcel, 10±-acre property, contains a vacant single-family residence at 660 Tank Farm Road (APN 053-421-004) which is to be demolished, while 3985 Broad Street (APN 053-421-003) is currently vacant; an earlier development was demolished several years ago. The site topography is relatively level and currently supports non-native annual grassland and ruderal habitats. There is existing soil stockpile on the southern area, which is to be used for the site grading of the proposed development. The site’s north and west boundaries are defined by drainage swales that flow west to the confluence with Orcutt Creek. The existing riparian habitat is generally in poor condition and will be enhanced as part of the project. As noted in the AASP, development in the area was intended to re-use and regenerate both the natural and built environments. The proposed projects are clearly representative of this vision. Attachment 2 Packet Page 47 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 4 of 14 IV. NARRATIVE PROJECT DESCRIPTIONS A. Shopping Center – NKT Development LLC The shopping center’s design team has availed themselves of the City’s regulatory framework with a special focus on the Community Design Guidelines. Specifically, Chapter 2 that describes the general design principles for site design and building design, and Chapter 3, §3.2 that focuses on the guidelines for large-scale retail projects and, expressly, the City’s expectations for quality and excellence in their design. 1. Project Description The proposed retail shopping center, located on the northwest corner of Broad Street and Tank Farm Road, occupies the easterly 5.28 acres of the overall project area. (The Westmont Living portion of the project is located west of the retail component.) The approximately 49,269 square feet of commercial building area is anchored by a 21,981 square foot grocer. Five (5) other buildings make up the remaining 27,288 square feet and will be comprised of a combination of retail shops and restaurants that include pedestrian-oriented exterior dining areas and plazas, and related circulation. Building # Building SF Description 1 21,981 Grocer 2 8,026 Retail 3 3,205 Retail 4 4,835 Restaurant 5 4,982 Restaurant 6 6,240 Retail/Restaurant 49,269 TOTAL SF 2. Site Plan Layout, Vehicular & Pedestrian Circulation Multiple points of access will serve the retail center. Access from Broad Street is provided by a driveway located along the northerly property line. This driveway will also provide access to the SESLOC building. To avoid a proliferation of access points, the existing right -in/right-out driveway access to SESLOC from Broad Street will be eliminated. Access from Tank Farm Road is proposed via a north- south driveway that is shared with the Westmont Living portion of the site. This driveway will access to provide “back of house” and loading areas for both the anchor building and Westmont Facility. The access is designed in a woonerf2 style to promote non-vehicle connections and encourage vehicles to use alternative roads for “through” access. The site plan is configured with the smaller buildings located along the street frontages to form a “street wall” with the parking located between the perimeter buildings and the anchor grocer. The anchor building is located in the northwest quadrant with its entry set at the southeast corner of the footprint near the center of the site. This arrangement will enable the anchor building entry to be visible from both street frontages and between the other structures. The remaining buildings are held tight to the setback lines on the Broad Street and Tank Farm Road frontages. 2 Woonerf – a Dutch concept that translates to “living street” featuring human-centered design principles and improved safety for pedestrian and cyclists. Attachment 2 Packet Page 48 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 5 of 14 Paired groupings of buildings frame the main street corner, as well as the main entry at the northeast entry drive. Pedestrian access from the public sidewalk is provided at each corner of the site and at intermediate points, both on Broad Street and Tank Farm Road. At the “hard” corner of Tank Farm Road and Broad Street, a pedestrian walkway leads from the intersection diagonally between Buildings Three and Four through a dining patio. From the northeast corner at the entry drive on Broad Street , the pedestrian access passes through a patio and between Buildings Five and Six to the interior parking area and storefronts. Internal walkways link the retail buildings and connect to the Westmont Living project and the SESLOC property. 3. Architecture The building design vocabulary combines simple shed roof forms and overhangs with board and batten siding to emulate the massing, scale and materials found in rural structures. Individual wall planes and surfaces are articulated vertically and horizontally to provide variation dimensionally. In addition, a mix of storefront, plaster surfaces and vertical siding are incorporated to provide variation in wall finishes. Cantilevered awnings, canopies and trellis elements provide shade and an additional dimensional layer to the elevations. The color selections for the project is intended to reflect the natural color of the materials and a neutral earth tone palette. 4. Landscape Architecture The landscape concept is designed to create a “softscape” character consistent with San Luis Obispo’s vernacular landscape that is characterized by the natural, ornamental, and agricultural landscapes. The City of San Luis Obispo planning documents, such as the Airport Area Specific Plan and Community Design Guidelines informed the design to meet City goals, while creating a project specific attractive and sustainable landscape that complements and is consistent with neighboring urban landscapes. Plantings along streets will employ a relatively simple palette of trees, shrubs, and ground covers for continuity with the character of the local urban landscape. New sidewalks along Broad Street and Tank Farm Road include a 5-foot landscaped parkway. Between the new sidewalk and the proposed building is a landscaped area ranging in size from 11- to 35-feet in width. Trees and shrubs are selected to highlight building entries, complement building scale, and screen less interesting site features, such as trash enclosures and utilities. Plant material has been selected for drought-tolerance and to provide a variety of forms, leaf color and texture, and flower color to create variety and interest throughout the year, especially where adjacent to pedestrian pathways and gathering areas. Plant material has been located to respond environmental factors and provide cooling of ambient temperatures, by shading outdoor gathering areas and sun- exposed south- and west-facing building walls. Plant species are selected for compatibility with local microclimatic conditions and to assure long-term sustainability, an attractive appearance, and to reduce water use and maintenance needs. Irrigation system design will adhere to the City of San Luis Obispo Water Efficient Landscape Ordinance (WELO) by utilizing fully automatic “Smart” controllers, low-flow irrigation systems design which separates hydrozones and incorporates flow sensors and rain shutoff capabilities. Appropriate soil Attachment 2 Packet Page 49 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 6 of 14 amendments, fertilizers, and mulch will be utilized to provide root zone health and to improve the water holding capacity of the soil. B. Assisted Living Facility – Westmont Living Since, 1996, the principals of Westmont Living have been developing and operating high-quality senior housing communities throughout California and Oregon. Their highest priority is resident care and comfort. See www.westmontliving.com for additional company details. 1. Project Overview The Westmont Living project will occupy an approximate 4.79-acre portion of the 10-acre site. The two- story 133,655 square foot building contains 139 units consisting of 111 assisted living studio, one and two-bedroom suites and 28 memory care studios. The proposed program offers an “aging in place” model where residents join the community and services are provided on an “as needed” basis. The entire project will be licensed by the State of California as a residential care facility for the elderly (RCFE). Westmont Living residences are exclusively designed for persons 60 years of age or older, or persons under 60 years of age with comparable needs. Westmont Living’s typical resident is 84-years old, single, with either a desire for a socialized environment and the convenience of dining, activities and immediately available amenities, or is experiencing a growing need for personal assistance with daily activities. Approximately 10% of residents will be couples and fewer than 25% of residents drive their own cars. Services onsite include three meals per day, prepared from scratch by a dedicated culinary services team. Wait staff serve meals in the central dining room or residents may reserve the family dining room for a special event or intimate meal among loved ones. The facility has no set meal times allowing residents to dine according to their own schedule. Entertainment, activities and exercise programs, a movie theatre, and even a beauty/barber shop are available on-site. Physical fitness is a priority at Westmont Living communities, as residents gain vitality through strength training and cardiovascular exercise programs. Recreational activities also encourage residents to socialize and connect with one another. Regular planned group outings allow residents to visit museums and galleries or attend concerts and theater performances. Assisted living services and specialized services are additional and charged on an a la carte basis. This allows residents to pay only for the extra services they need. The community operates as a month-to-month tenancy, and there are no extravagant “buy in” costs. 2. Staffing, Visitors, and Guests The Westmont Living community is a 24-hour per day operation. A full-time general manager is on site to oversee daily operations of the facility. A management team consisting of a director of nursing, culinary director, business office manager, maintenance director, activities director, memory care director, and memory care activities director supports the general manager. Based on the proposed size Attachment 2 Packet Page 50 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 7 of 14 of the facility, there would be approximately eighty (80) employees, including full-time and part-time positions. A typical daytime shift consists of eighteen (18) employees on-site. In addition to Westmont Living staff, private contractors, including food delivery, hospice care, and landscape maintenance staff, provide additional services. The maximum number of private contractors on the premises at any one time is estimated to be four. This anticipates a worst-case scenario, in which food delivery, hospice care and landscaping were to occur at the same time. Food delivery will typically occur on a weekly schedule and at non-peak traffic times, such as very early mornings, mid -mornings, or early afternoon. Visitors typically arrive throughout the day, with most visits occurring between 9 :00 a.m. to 7:00 p.m. On a typical day, there are no more than five (5) total visitors. 3. Vehicular & Pedestrian Circulation The project site is designed to obtain access from Tank Farm Road at the MindBody signalized intersection. Access to the rear of the building (i.e., back of house) is from the right in/right out “woonerf” driveway serving both the shopping center and assisted living facility. The signalized intersection at Tank Farm Road allows for access to the SESLOC facility to the north and, ultimately, to the signalized intersection at Industrial Way and Broad Street. This main entry drive (really a private road with a public access easement, similar to SESLOC’s roadway) encroaches slightly into the designated “creek setback”. The top of bank and the noted encroachment has been reviewed on-site with the City’s Natural Resource Manager. To compensate for this minor encroachment, the project includes enhancement of the drainage swale to create a riparian corridor. See Appendix A for an exhibit of the creek setback encroachment areas. The entry to the facility is off the main driveway and noted with a porte cochere and drop off area. Guest parking, van, and accessible parking is located at the front of the building with employee parking at the rear. Pedestrian connections (i.e., designated crossings) are provided from the assisted living facility to the shopping center, as well as to the SESLOC facility. Typically, very few residents drive or bring their vehicles with them when they move to a Westmont Living facility. As such, a private luxury minivan takes residents shopping, to doctor’s appointments, and to various activities within the greater community. Since residents seldom drive and transportation is provided by the facility, less than two (2) trips per day per suite is expected for visitors and staff, which are primarily outside of peak hours. This is significantly lower than a conventional residential or commercial development and without the peak hour trip generation. This development is proposing seventy (70) total spaces, including four (4) accessible spaces. With a total of 139 suites, this represents a ratio of 0.50 parking space/unit. The parking ratio allows an increase in landscaping and open space to create a better environment for r esidents and adjacent property owners. Six (6) short- and five (5) long-term bicycle parking is also provided. As a comparison the City’s Zoning Regulations require 1 parking space for every 4 beds in a residential care. There are is a total of 150 beds proposed, this equates to a requirement of 38 parking spaces. Attachment 2 Packet Page 51 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 8 of 14 4. Building Layout & design The building layout for an assisted living and memory care community provides for the unique health, safety and welfare needs of the seniors it serves. Residents require easier access to amenities and activities through reduced walking distances, additional security and safety, as provided by 24- hour staff availability. In addition, social and physical activities promote interaction and reduce isolation. The entire building is ADA accessible, as are individual suites. Suites are barrier free, include grab bars in bathrooms, and provide emergency pull cord systems to alert staff of an emergency. These design features combined with 24-hour staffing ensure the safety and protection of residents who otherwise would be at risk living completely independently. Assisted living suites contain a stackable washer/dryer and private full bath with accessible shower enclosure. One and two-bedroom suites contain kitchens with a sink, dishwasher, cabinets, microwaves, and ovens with range tops. Studios provide kitchenettes that do not have ovens or dishwashers but include a cooktop, refrigerator, and microwave. By providing the services and conveniences of home, the program helps smooth the transition process for residents into higher levels of care. The memory care neighborhood contains private memory care suites, a large communal dining room, activity and living areas, along with a private secure memory care courtyard. Private memory care suites each have a full bath, but do not contain kitchenettes or stackable washer/dryers. The memory care neighborhood has a secured perimeter, offering superior individualized care for residents suffering from Alzheimer’s Disease or other age-related dementias. The building design utilizes internal courtyards, increasing daylight throughout the building and providing secure outdoor space for residents. The circular formation of the wing provides shortened travel distances to common spaces, amenities, dining rooms, and staff. The assisted living and memory care programs share a single commercial kitchen, commercial laundry facilities, and staff areas, which are centrally located for efficiency. Common areas are located throughout the building to provide easy access to all residents. While resident’s privacy is important, the design of the building encourages interaction with neighbors, sharing in onsite activities, and visiting with staff. Loneliness and isolation along with physical constraints and ambulatory concerns are addressed with the building design. 5. Architecture The proposed two-story, thirty-two (32) foot high building’s design incorporates the architectural style and materials from the surrounding neighborhood and the eclectic styles found within the City. The color palette is decidedly neutral, and materials consist of a mix of lap siding, stucco, board and batten, and stone veneer to create a natural look. While the assisted living facility represents the residential component of this overall mixed-use project, its architectural language communicates with the style proposed for the shopping center. The project will also include the liberal use of wood columns and Attachment 2 Packet Page 52 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 9 of 14 beams with restrained use of stone veneer to accent the main entry. Individual wall planes and surfaces are articulated vertically and horizontally to provide variation dimensionally. 6. Landscape Architecture The modifications to the Tank Farm Road right-of-way includes a 5-foot landscaped parkway. Between the new sidewalk and the proposed building is a landscaped area ranging in size from 15 -feet to 30-feet. Pedestrian circulation from the new sidewalk to the facility is provided at both entry points. Public art is proposed for the large landscaped area in the front of the facility. Private landscaped courtyards provide areas of outdoor respite for the residents, while maintaining the requisite safety and security. The landscape around the building exterior provides additional visual interest and texture. The planting palette includes some of the same plants used in the shopping center design, providing additional continuity within the project. Plant material has been selected for drought-tolerance and the irrigation system design will adhere to the City of San Luis Obispo Water Efficient Landscape Ordinance (WELO) by utilizing fully automatic “Smart” controllers, low-flow irrigation systems design which separates hydrozones and incorporates flow sensors and rain shutoff capabilities. C. Site Design & Related Improvements 1. Parking The proposed project utilizes the Citywide parking regulations and existing AASP parking regulations as the basis for determining the parking requirement for the project. Specific parking requirements are provided in the draft AASP amendment text. Due to the assisted living and shopping center operational requirements, there is separate parking for each component. The Shopping Center parking will be a shared parking facility between the six (6) parcels/buildings. Based on the parking regulations, the shopping center requires a 20% parking reduction from the parking standards. This is consistent with the Zoning Regulation’s Shared Parking Reduction (§17.72.050) available via Director’s Action. Other types of parking are provided, consistent with the Zoning Regulations. Parking Calculations Lot # USE Square Feet Other Quantity Calculation Parking Required Parking Provided 1 ASSISTED LIVING 133,655 144 Beds 1 space /5 beds 28.8 70 (continuing care community) 18 employees 1 space/ 2 emp. 9.0 Assisted Living Total 37.8 70.0 Attachment 2 Packet Page 53 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 10 of 14 SHOPPING CENTER 2 Retail Bldg. 2 8,026 1 space / 300 SF 26.8 19 3 Retail Bldg. 3 3,205 1 space / 300 SF 10.7 10 4 Restaurant Bldg. 4 4,835 1 space / 100 SF 48.4 38 5 Restaurant Bldg. 5 4,982 1 space / 100 SF 49.8 34 6 Retail/Restaurant Bldg. 6 6,240 34 Retail 3,240 1 space / 300 SF 10.8 Restaurant 3,000 1 space / 100 SF 30.0 7 Grocer Bldg. 1 21,981 1 space / 250 SF 87.9 79 Subtotal 264.3 214.0 Requested Shared Parking Reduction 20% -52.9 Shopping Center Total 211.5 214.0 Project Total 249.3 284.0 MISC. PARKING CALCULATION REQUIRED PROVIDED Accessible Parking Per Title 24 14 Shopping Center 10 Assisted Living 4 Clean Air/EV Stations Retail and Residential = 10% of vehicle spaces 30 33 Shopping Center 26 31 Assisted Living 4 2 Motorcycle Parking 1/20 vehicle spaces 15 11 Shopping Center 13 11 Assisted Living 2 - Bike Parking 62 51 Shopping Center 20% of vehicle spaces 53 32 minimum short-term 75% of bike spaces 40 40 minimum long-term 25% of bike spaces 13 16 Assisted Living* 17.72.070.D; Alt compliance; 1 space / 2 shift employees 9 11 minimum short-term 6 minimum long-term 5 2. Drainage The proposed retail shopping center has been designed to manage stormwater runoff from the six (6) proposed buildings, landscaping, parking and drive aisles, and direct the water into underground storage facilities. The impervious areas on site have been design with slopes and grading to direct stormwater Attachment 2 Packet Page 54 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 11 of 14 through a storm drain system that will route the stormwater to the two (2) proposed underground storage facilities. The attached Storm Water Control Plan (See Appendix B) has been prepared to demonstrate how the underground storage facilities will treat and retain the 95th percentile storm event on site, while managing the peak flows for the 2-year through 10-year storm event. The proposed stormwater system has been designed to be in compliance with the City of San Luis Obispo’s Post-Construction Storm Water Requirements (PCR) that requires that the post-developed flows not exceed those of the pre-developed conditions. In addition to the PCRs, an additional drainage study was completed to support how the proposed storm drain system meets the City of San Luis Obispo’s Retardation Basin Capacity Standards. The study confirms that the post-developed construction peak flows for larger storm events do not exceed those of the pre-developed conditions. (See Appendix C) 3. Utilities The proposed project will have domestic water, recycled water, sewer, and fire services. See the Composite Utility Plan/ C-1 & C-1W, Bethel Engineering, for layout and the related easements. Easements are also shown on the Vesting Tentative Tract Map. The specific buildings and related services are noted below 3. Public Improvements The Airport Area Specific Plan (AASP) identifies several public improvements (PIPs) that have been incorporated into the project and, more specifically, includes improvements along Tank Farm Road and Broad Street, and related utility tie-ins. The public improvements are depicted on Sheets 1 – 7 of the PIP plan set (Bethel Engineering). All roadway improvements reflect the proposed sections noted in the AASP with the exception that the travel lanes on Tank Farm Road are noted as eleven (11) feet versus twelve (12) feet. This design exception is presented on Exhibit A – Specific Plan Tank Farm Road Full Build-out, (Bethel Engineers, 05 Dec 2017). Exhibit B depicts the project proposed street section along Tank Farm Road. (See Appendix D) The constraints associated with the “full” build-out include: 1) Additional “take” along the shopping center project; 2) Conflicts with the existing drainage facilities at the MindBody intersection; 3) Relocation of the ex. signal pole; and 4) A sixteen (16) foot jog in the west bound through lane at the intersection. The above-mentioned design exception has been reviewed by City Public Works/Transportation staff and found to be an acceptable design exception. Phasing of the various on and off-site improvements has been provided with the PIPs (See Construction Phasing Plan, Oasis Associates). This includes mass and precise grading, interior access roads, street frontage improvements (including curb, gutter and sidewalk and parkways), and utility connections. The proposed Broad Street entry to the shopping center will require removal of the right -in/right-out entry to the SESLOC property, north of and adjacent to the shopping center. Attachment 2 Packet Page 55 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 12 of 14 4. Biological Resources The site currently supports disturbed non-native annual grassland and ruderal habitats (i.e., previously disturbed). The majority of the site has been developed with buildings, etc., as recent as 2003, and dating back to at 1937. The residential development at 3985 Broad Street appears to have been vacant between 2004 and 2013 when buildings were removed, and the surface was cleared leaving only the non-native trees. The existing residence at 660 Tank Farm Road is to be removed as part of the proposed development. An approved soil stockpile has been placed on the southwest corner of the property. An ephemeral drainage with a low-flow channel and a small adjacent wetland floodplain at the eastern reach enters the site through a 24-inch culvert in the northeast corner of the property (across from the Marigold Center entry of Broad Street) and flows west to the confluence with Orcutt Creek, located in the northwest corner of the shopping center site. Orcutt Creek flows southwesterly along the west edge of the assisted living property to a culvert under Tank Farm Road. The property is bordered by urban development on the north, east, and south sides with residential development to the west. A Biological and Wetland Resources Assessment has been completed for the subject properties (See Appendix E). The AASP acknowledges and supports the “re-use and regeneration of both the natural and built environments”. Part of the project(s) description is to enhance the riparian corridor and replace a small wetland removed to enable the entry off Broad Street. Based on the existing conditions of the site(s), project implementation would not result in any substantial adverse effects on biological, botanical, wetland, or riparian habitat resources. While the site, grading, and architectural plans identify improvements adjacent to the existing low-flow channels, the measures incorporated into the project(s), will render both direct and indirect project impacts on biological and wetland resources less than significant. In addition, given the mostly ruderal habitat affected within the urbanized City of San Luis Obispo, the proposed project impacts would not be considered cumulatively considerable. V. PROJECT PROCESSING AND APPROVAL(S) COMPONTENTS A. Environmental Determination The Land Use and Circulation Element (LUCE) update was supported by an Environmental Impact Report [(EIR) 2035 Land Use & Circulation Update, Final Program EIR, September 2014, SCH#2013121019]. The program EIR included the subject property - Site ‘R’ and anticipated a mix of residential units and commercial square footage. The proposed project(s) are consistent with the identified and intended project outlined in the LUCE EIR and should be used to inform any additional environmental analysis. In that context, additional project specific analysis and reports are included with this application to provide City staff with the detailed information to complete an Initial Study. The resulting environmental determination is to be reviewed by the Planning Commission with a recommendation to the City Council for their ultimate review and adoption. . B. Airport Area Specific Plan Amendment While the Land Use & Circulation Element (LUCE) update included the subject properties and the subsequent change in land use classification, it is now incumbent upon the project applicants to modify the Airport Area Specific Plan to include the LUCE modifications. While the proposed projects require Attachment 2 Packet Page 56 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 13 of 14 amendment of the AASP to reflect the vision of the LUCE, new zoning, and specific projects , the proposed draft amendment simply added text to section 4.0 Land Use/Land Use Background/Special Areas. The proposed amendment includes information regarding the site’s designation in the LUCE; that these are the only CC-SF zoned properties in the AASP; and reference to this development plan (once approved) with project specific development standards. The proposed project generally complies with the C-C and O City-wide development standards or AASP development standards, however, the amendment to the AASP includes minor modifications and flexibility for the development standards specific to these special focus properties. Appendix F is provided as a comparison of the proposed project and the City-wide development standards (based on the 2015 Zoning Regulations) for the subject property zoning. C. Vesting Tentative Tract Map The project(s) site consists of two (2) legal parcels – 053-421-003 and 004. To facilitate the orderly development of the proposed projects, a vesting tentative tract map is being proposed to provide a parcel for the assisted living facility and multiple parcels for the shopping center. The parcelization of the shopping center into six (6) lots reflects the current trend of retail center business models. The vesting tentative tract map 3115 – creates a total of seven (7) lots. The following is a breakdown of the proposed lots. (The vesting tentative tract map is included in the project plan set). Lot # Area Square Ft AC USE Building SF* 1 208,764 4.79 Assisted Living Facility 133,6551) 2 23,718 0.54 Shopping Center 8,026 3 16,007 0.37 Shopping Center 3,205 4 33,015 0.75 Shopping Center 4,835 5 28,920 0.66 Shopping Center 4,982 6 52,196 1.20 Shopping Center 6,240 7 76,499 1.76 Shopping Center 21,981 1) In two-stories. D. SLO County Airport Land Use Plan - A Finding of Consistency On September 19, 2018 the Airport Land Use Commission’s (ALUC) reviewed and found the AASP amendment and development project are in substantial conformance with the Airport Land Use Plan (ALUP). Justifications for the finding of consistency included items related to the assisted living facility’s specific operations as a “shelter in place” facility, compliance with the non-residential density requirements of the applicable safety areas, and general compliance with the City’s Zoning Regulations for building height and coverage area. . E. Archtectural Review Commission The design of the project was reviewed by the Architectural Review Commission (ARC) on October 15, 2018. The ARC provided a recommendation for approval with a list of directional items. Design revisions were completed in response to the ARC direction and are incorporated into the most current development plans. Further details regarding the design revisions and modification are outlined in the Attachment 2 Packet Page 57 NKT Commercial LLC & Westmont Development LP Broad Street and Tank Farm Road Mixed Use Oasis Associates, Inc. January 8, 2019 14 of 14 “Post-ARC Project Updates” (20 December 2018) provided as an attachment to the December 18, 2018 Development Plan Set and attached here. VI. ADDITIONAL INFORMATION - LIST OF APPENDICES Additional supporting documents have been compiled for the proposed development. The documents are provided pursuant to the related Application Checklist(s), as relevant to the nature of this project. ATTACHMENTS 1. DRAFT AIRPORT AREA SPECIFIC PLAN AMENDMENT TEXT, Oasis Associates, Inc., January 7, 2019 2. DEVELOPMENT PLAN SET, December 18, 2018 • Mixed Use: Commercial Shopping Center Conceptual Design Plans • Mixed Use: Assisted Living Conceptual Design Plans • Public Improvement Plans • Vesting Tentative Tract Map 3115 3. FINDING OF CONSISTENCY, Airport Land Use Commission, 19 September 2018 4. POST-ARC PROJECT UPDATES, Oasis Associates, Inc. 20 December 2018. APPENDICES OF SUPPORTING DOCUMENTS (provided with initial application submittal package, 20 March 2018) A. Creek Setback Exhibit, Oasis Associates, Inc., 03 October 2017 B. Stormwater Control Plan, Bethel Engineering, 12 March 2018 ▪ Commercial Center ▪ Westmont Assisted Living C. Flood Control: Drainage Study, Bethel Engineering, 12 March 2018 ▪ Commercial Center ▪ Westmont Senior Living D. Public Improvement Plan Exception Exhibits A, B, & C, Bethel Engineering, 12 March 2018 E. Biological & Wetland Resource Assessment, Sage Institute, 16 March 2018 F. Development Standards Comparison, Oasis Associates, Inc., 20 March 2018 G. Airport Land Use Commission Discussion Memo, Westmont Living, 28 July 2017 H. Preliminary Title Reports, Fidelity National Title Company, 27 September 2017 I. Acoustical Assessment, 45dB Acoustics, 31 October 2017 J. LEED Checklist (v4 for BD+C) ▪ Commercial Shopping Center ▪ Westmont of San Luis Obispo 30 January 2018 K. Applicant’s Determinant Project Schedule, 20 March 2018 L. Multimodal Transportation Impact Study, Central Coast Transportation Consulting, February 2018 Attachment 2 Packet Page 58 PROPERTY INFORMATION 10.20 Acres 3985 Broad Street (053-421-003) 660 Tank Farm Road (053-421-004) ZONING Community Commercial Special Focus Overlay (C-C-SF) Business Park with Specific Plan Overlay (BP-SP) SCOPE OF WORK A mixed-use development project comprised of general retail and senior assisted living facility. Includes 45,269 square feet of commercial building area, anchored by a 21,981 square foot grocer and five (5) other buildings make up the remaining 17,981 square feet for retail and restaurant uses. The assisted living facility is a two-story 133,655 square foot facility providing 111 assisted living suits and 28 memory care beds (constructed in two phases). Project includes a vesting tentative tract map 3115 for seven (7) lots , public improvements (with design exceptions), site improvements typical to new development, riparian and wetland enhancement, and an amendment to the Airport Area Specific Plan. NWC BROAD STREET at TANK FARM ROAD SAN LUIS OBISPO, CA 93401 SHEET INDEX Mixed Use Commerical Shopping Center Cover Sheet RE-01 Color Rendering RE-02 Color Rendering RE-03 Color Rendering A010 Site Plan C-1 Preliminary Grading Plan C-2 Preliminary Grading Plan C-3 Preliminary Utility Plan L1 Landscape Plan L2 Landscape Notes A101 Building-1 Floor Plan A131 Building-1 Roof Plan A201.1 Building-1 Elevations A201.2 Building-1 Elevations A301 Building-1 Wall Sections A102 Building-2 Floor Plan A132 Building-2 Roof Plan A202 Building-2 Elevations A302 Building-2 Wall Sections A103 Building-3 Floor Plan A133 Building-3 Roof Plan A203 Building-3 Elevations A303 Building-3 Wall Sections A104 Building-4 Floor Plan A134 Building-4 Roof Plan A204 Building-4 Elevations A304 Building-4 Wall Sections A105 Building-5 Floor Plan A135 Building-5 Roof Plan A205 Building-5 Elevations A305 Building-5 Wall Sections A106 Building-6 Floor Plan A136 Building-6 Roof Plan A206 Building-6 Elevations A306 Building-6 Wall Sections TR-01 Trash Enclosure EPH-01 Lighting Plan IM-01 Image Reference CM-01 Color Material Board Mixed Use Assisted Living Development A0.0a A1.1 A1.7 A3.1 A3.2 A5.1 A6.0 A6.3 L1 L2 E1.1 Cover Sheet Site Plan Site Details st Floor Plan 2nd Floor Plan Color Board Image Reference Building Sections Building Elevations Landscape Development Plan Courtyard Landscape Development Plan Site Lighting Plan 1 of 9 Rendering 1 2 of 9 Rendering 2 3 of 9 Rendering 3 4 of 9 Rendering 4 5 of 9 Rendering 5 6 of 9 Rendering 6 7 of 9 Rendering 7 8 of 9 Rendering 8 9 of 9 Rendering 9 C-1W Preliminary Grading Plan C-2W Preliminary Grading Plan Section and Details Public Improvement Plans 1 2 3 4 5 6 7 8 Title Sheet Tank Farm Road - Surface Plan and Profile Broad Street- Surface Plan and Profile Tank Farm Road- Underground Plan and Profile Broad Street- Underground Plan and Profile Tank Farm Road & Broad Street Striping Plan Tank Farm Road & Mindbody Signal Plan Phasing Plan Vesting Tentative Tract Map 3115 Sheet 1 Of 2 Sheet 2 Of 2 SUPPORTING DOCUMENTS, REPORTS AND ANALYSES PROVIDED WITH APPLICATION A.Creek Setback Exhibit, Oasis Associates, Inc., 03 October 2017 B.Stormwater Control Plan, Bethel Engineering, 12 March 2018 •Commercial Center •Westmont Assisted Living C.Flood Control: Drainage Study, Bethel Engineering, 12 March 2018 •Commercial Center •Westmont Senior Living D.Public Improvement Plan Exception Exhibits A, B, & C, Bethel E.Biological & Wetland Resource Assessment, Sage Institute 16 March 2018 F.Development Standards Comparison, Oasis Associates, Inc., 20 March 2018 G.Airport Land Use Commission Discussion Memo, Westmont Living, 28 July 2017 H.Preliminary Title Reports, Fidelity National Title Company, 27 September 2017 I.Acoustical Assessment, 45dB Acoustics, 31 October 2017 J.LEED Checklist (v4 for BD+C) •Commercial Shopping Center •Westmont of San Luis Obispo 30 January 2018 K.Determinant Project Schedule, 20 March 2018 L.Multimodal Transportation Impact Study, Central Coast Transportation Consulting, February 2018 PROPERTY OWNER NKT DEVELOPMENT, LLC c/o Nick Tompkins 684 Higuera Street, Suite B San Luis Obispo, CA 93401 (805)-541-9004 APPLICANT’S AGENT OASIS ASSOCIATES, INC. c/o C.M. Florence, AICP & Emily Ewer, AICP 3427 Miguelito Court San Luis Obispo, CA 93401 (805) 541-4509 cmf@oasisassoc.com emily@oasisassoc.com PROJECT LOCATION APPLICANT NKT DEVELOPMENT, LLC c/o Nick Tompkins 684 Higuera Street, Suite B San Luis Obispo, CA 93401 (805)-541-9004 ARCHITECT McKENTLY MALAK ARCHITECTS c/o Ken McKently, AIA 35 Hugus Alley Ste 200 Pasadena, CA 91103 (626) 583-8348 ken@mckently.com CIVIL ENGINEER BETHEL ENGINEERING c/o Lori Speer, PE 2624 Airpark Drive Santa Maria, CA 93455 (805) 934-5767 lori@dbaengineers.com LANDSCAPE ARCHITECT SMP ENVIRONMENTAL DESIGN c/o James L. Burrows 979 Osos Street, Suite B6, San Luis Obispo, CA 93401 (805) 439-3209 jburrows@smpinc.net ELECTRICAL ENGINEER THOMA ELECTRIC, INC. c/o James J. Dean 3562 Empleo Street Suite C San Luis Obispo, CA 93401 (805) 543-3850 Jdean@thomaelec.com MIXED USE COMMERCIAL SHOPPING CENTER SITE MIXED USE COMMERCIAL SHOPPING CENTERMIXED USE ASSISTED LIVING DEVELOPMENT APPLICANT WESTMONT DEVELOPMENT, LP c/o Michael O’Rourke 7660 Fay Avenue, Ste M La Jolla, CA 92037 (415) 317-9969 ARCHITECT LENITY ARCHITECTURE c/o Aaron Clark, AIA 3150 Kettle Court SE Salem, OR 97301 (503) 399-1090 aaronc@lenityarchitecture.com CIVIL ENGINEER BETHEL ENGINEERING c/o Lori Speer, PE 2624 Airpark Drive Santa Maria, CA 93455 (805) 934-5767 lori@dbaengineers.com LANDSCAPE ARCHITECT LENITY ARCHITECTURE c/o Brian Lind 3150 Kettle Court SE Salem, OR 97301 (503) 399-1090 brianl@lenityarchitecture.com BIOLOGIST SAGE INSTITUTE, INC. c/o David K. Wolff 1320 Van Beurden, Ste 202-D4 Los Osos, CA 93402 (805) 434-2804 x 102 dwolff@sageii.com MIXED USE ASSISTED LIVING CENTER A5.2 Date: December 18, 2018 SP-1 Consolidated Site Plan SP-2 Woonerf Render 1 SP-3 Woonerf Render 2 Attachment 3 Packet Page 59 NWC TANK FARM & BROAD STREET SAN LUIS OBISPO, CA CONCEPTUAL SITE PLAN 2/5/19 SP-1 SCALE: 1”=30’ KEYNOTE LEGEND 1 ENHANCED PAVING AT BUILDING ENTRY & PLAZAS 2 ENHANCED RIPARIAN CORRIDOR 3 OUTDOOR PLAZA SEATING AREA 4 TRAFFIC-CALMING WOONERF 5 PEDESTRIAN CONNECTION # ARC REVISION LEGEND A E-W PEDESTRIAN WALKWAY BETWEEN BUILDINGS 1 & 5 B N-S PEDESTRIAN WALKWAY BETWEEN BUILDINGS 4 & 5 C TRELLIS STRUCTURES ADDED ALONG PEDESTRIAN WALKWAYS D BUILDING 6 SHIFTED TO PROVIDE ADDITIONAL PLAZA SPACE E INCREASED N-S DRIVE AISLES BETWEEN BUILDINGS 2 & 3 F SIGNAGE MOVED FROM WALL TO CANOPY, ALL BUILDINGS G DECOMPOSED GRANITE PATHWAY H BICYCLE PARKING I ENHANCED PAVEMENT AT PEDESTRIAN CONNECTIONS WESTMONT SENIOR LIVING BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 BUILDING 6 BROAD STREETTANK FARM ROAD 1 1 1 3 3 4 4 5 5 5 5 5 5 5 55 5 5 2 3 5 5 5 5 5 5 # A B C C C C D E E G G G I I I I I H H H 2 2SITE SECTION A-A - NOT TO SCALE A A Attachment 3 Packet Page 60 NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, CaliforniaNKT COMMERCIAL, LLCVIEWKEYPLANVIEW OF WOONERF STREET BEHIND BUILDING-1 LOOKING SOUTHSP-2 Woonerf RenderingAttachment 3Packet Page 61 NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, CaliforniaNKT COMMERCIAL, LLCVIEWKEYPLANVIEW OF WOONERF STREET BEHIND BUILDING-1 LOOKING SOUTHWESTSP-3 Woonerf RenderingAttachment 3Packet Page 62 NKT COMMERCIAL, LLCMcKently Malak Architects35 Hugus Alley, Suite 200Pasadena, CA 91103T: 626.583.8348Contact: Ken MckentlyE-mail: ken@mckently.comARCHITECTSMP Environmental Design979 Osos Street., Suite B6San Luis Obispo, CA 93401T: 805.439.3209Contact: James L. BurrowsE-mail: jburrows@smpinc.netLANDSCAPEARCHITECTNKT DEVELOPMENT, LLC684 Higuera Street, Suite BSan Luis Obispo, CA 93401T: 805.541.9004Contact: Nick TompkinsE-mail: nick@nktcommercial.comContact: Steve SimoulisE-mail: steve@nktcommercial.comOWNER /APPLICANTBethel Engineering2624 Airpark DriveSanta Maria, CA 93455T: 805.934.5767Contact: Lori SpeerE-mail: lori@dbaengineers.comCIVILENGINEERThoma Electric, Inc.3562 Empleo Street, Suite CSan Luis Obispo, CA 93401T: 805.543.3850Contact: James J. DeanE-mail: JDean@thomaelec.comELECTRICALENGINEERCOVER SHEETRE-01 COLOR RENDERINGRE-02 COLOR RENDERINGRE-03 COLOR RENDERINGA010 SITE PLANC-1 PRELIMINARY GRADING PLANC-2 PRELIMINARY GRADING PLANC-3 PRELIMINARY UTILITY PLANL1 LANDSCAPE PLANL2 LANDSCAPE PLANA101 BUILDING-1 FLOOR PLANA131 BUILDING-1 ROOF PLANA201.1 BUILDING-1 ELEVATIONSA201.2 BUILDING-1 ELEVATIONSA301 BUILDING-1 WALL SECTIONSA102 BUILDING-2 FLOOR PLAN A132 BUILDING-2 ROOF PLANA202 BUILDING-2 ELEVATIONSA302 BUILDING-2 WALL SECTIONSA103 BUILDING-3 FLOOR PLANA133 BUILDING-3 ROOF PLANA203 BUILDING-3 ELEVATIONSA303 BUILDING-3 WALL SECTIONSA104 BUILDING-4 FLOOR PLANA134 BUILDING-4 ROOF PLANA204 BUILDING-4 ELEVATIONSA304 BUILDING-4 WALL SECTIONSSHEETINDEXA105 BUILDING-5 FLOOR PLANA135 BUILDING-5 ROOF PLANA205 BUILDING-5 ELEVATIONSA305 BUILDING-5 WALL SECTIONSA106 BUILDING-6 FLOOR PLANA136 BUILDING-6 ROOF PLANA206 BUILDING-6 ELEVATIONSA306 BUILDING-6 WALL SECTIONSTR-01 TRASH ENCLOSUREEPH-01 LIGHTING PLANIM-01 IMAGE REFERENCECM-01 COLOR MATERIAL BOARDSAN LUIS OBISPO, CALIFORNIANOVEMBER 14, 2018NWC TANK FARM ROAD & BROAD STREETAttachment 3Packet Page 63 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateVIEW FROM TANK FARM ROAD AND BROAD STREET LOOKING NORTHWESTCOLOR RENDERINGRE-01VIEWKEYPLANAttachment 3Packet Page 64 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateCOLOR RENDERINGRE-02VIEW FROM TANK FARM ROAD AND BROAD STREET LOOKING NORTHWESTKEYPLANVIEWAttachment 3Packet Page 65 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateCOLOR RENDERINGRE-03VIEW FROM BROAD STREET LOOKING SOUTHWESTKEYPLANVIEWAttachment 3Packet Page 66 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018Date5SITE PLANA-010BIKE RACKSREVISION04.25.201807.02.2018BIKE RACKS12.11.2018NO PARKING NO PARKINGNO PARKINGNO PARKING LOADING ONLY / NO PARKINGLOADING ONLY / NO PARKINGLOADING ONLY / NO PARKINGLOADING ONLY / N O P A R K I N G EVSTATIONEVSTATIONAMBULATORYEVSTATIONEVSTATIONEV STATION EV STATION EV STATION EVSTATIONVANACCESSIBLEEVSTATIONEVSTATIONEVSTATIONEVSTATIONEVSTATIONSTANDARDACCESSIBLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEAN AIR VEHICLE CLEAN AIR VEHICLE CLEANAIRVEHICLECLEANAIRVEHICLEPROJECTSIGNWALKLSTOP OF BANK35' SETBACK FROMTOP OF BANKPROPERTY LINEPROPERTY LINE1272239661510WALKGENEQLANDSCAPEPROPERTY LINE N 64°57'46" E704.23'93'-4"86'57'-10"74'35'20'25'37'CARTS119'-4"178'119'-4"24'-8"30'111162393012613916653123625850'124'-10"84'60'BUILDING 1PROPOSED±21,981 S.F.10'30'18'-6"25'18'-6"18'-6"25'18'-6"18'-6"30'18'-6"18'-6"30'18'-6"10'18'-6"26'18'-6"55'18'-6"26'26'26'18'-6"18'-6"25'18'-6"18'-6"30'25'18'-6"30'CARTSCARTSCARTS20'5'20'10'30'45'DRIVEWAYDRAINAGE EASEMENTSEWER EASEMENT65'-5"BLDG.BP-SP(BUSINESS PARK - SPECIFIC PLAN AREA)LANDSCAPED AREA26'18'-6"TRASHENCLOSURETRASHENCLOSUREPLAZAP L A N T E RLOADING DOCKP L A N T E RL A N D S C A P E D A R E AL A N D S C A P E D A R E ALANDSCAPED AREA9'TYP9'TYP9'TYP9'PROPERTY LINEPROPERTY LINEPROPERTY LINE18'-6"26'18'-6"9'TYP9'9'TYP9'TYP9'TYPP L A N T E RS I D E W A L K15'15'S I D E W A L KP L A N T E RCART STORAGECART STORAGEENTRY/EXITEXITSIGNALIZEDINTERSECTIONSIGNALIZEDINTERSECTION30'DRIVEWAY30' PUBLIC ACCESSEASEMENT6' PUBLIC PEDESTRIANEASEMENTFLOOR AREA: 6,188 SFROOF ACCESS 52 SFTOTAL AREA: ± 6,240 SFSWITCHGEARFLOOR AREA: 4,932 SFROOF ACCESS 50 SFTOTAL AREA: ± 4,982 SFELEC.BUILDING 6PROPOSEDBUILDING 5PROPOSEDFLOOR AREA: 4,785 SFROOF ACCESS 50 SFTOTAL AREA: ± 4,835 SFBUILDING 4PROPOSEDFLOOR AREA: 3,152 SFROOF ACCESS 53 SFTOTAL AREA: ± 3,205 SFBUILDING 3PROPOSEDFLOOR AREA: 7,973 SFROOF ACCESS 53 SFTOTAL AREA: ± 8,026 SFBUILDING 2PROPOSED5'12'26'FIRELANESWITCHGEARSWITCHGEARSWITCHGEARSWITCHGEAR02020303010104150404010103030503010306060607070707101010101111111111121313131414141414141425'18'-6"8'9'03010602148'4'01036'-6"MOTORCYCLEMOTORCYCLEGAS SERVICEELECTRICAL SERVICE6" FIRE LINE1 1/2" DOMESTIC WATERTELEPHONE SERVICE18'-6"30'15'-3"BLDG.11'-9"15'-4"BLDG.21'20'-3"BLDG.17'-9"35'-11"BLDG.13'8'20'18'-8"10'-6"33'13'11'7'12'6'PROPOSED SIGNPROPOSED SIGNPLAZATRASHENCLOSURE19'8'30'28'18'-10"BLDG.06OUTDOORSEATING16161616060606PROPOSED SITE PLANSCALE: 1" = 40'-0"VICINITY MAPNORTHNOT TO SCALENWC BROAD STREET & TANK FARM ROADSAN LUIS OBISPO, CALIFORNIAPRELIMINARY SITE PLAN SUBJECT TO CHANGE.1 inch = feetGRAPHIC SCALE0404080401602025'-0"STANDARD PARKING STALLGROSS SITE AREA BUILDING-5 (RESTAURANT)REQUIRED PARKING IS PER SPECIFIC PLAN TOTALSITE DATAZONINGZONINGCOMMUNITY COMMERCIAL WITHMIN. DRIVE AISLE MIN. WIDTHSITE LAYOUT DATAPARKING DATABUILDING AREA9'-0" x 18'-6"BUILDING DATABUILDING-4 (RESTAURANT)SITE AREASPECIAL FOCUS OVERLAY (C-C-SF)±236,348 SF053-421-003APN(S) ±5.42 AC214 STALLSBUILDING-1 (GROCERY)±4,982 SF ±21,981 SF BUILDING-2 (RETAIL)±8,026 SF ±49,269 SF ±4,835 SF AMENDMENT.PARKING PROVIDEDF.A.R. (±49,269 S.F. / ±230,355 S.F.) =0.214.34 / 1,000 S.F.PARKING RATIO169 STALLSSTANDARD:10 STALLSHANDICAPPED:BUILDING-3 (RETAIL)±3,205 SF BUILDING-6±6,240 SF 13 STALLSEV STATIONS:18 STALLSCLEAN AIR VEHICLES:053-421-004NET SITE AREA ±230,355 SF ±5.28 ACCITY OF SAN LUIS OBISPOJURISDICTION11 STALLSMOTORCYCLE (4'X8')8 LOCKERS FOR 16 BIKESBIKE LOCKERS20 RACKS FOR 40 BIKESBIKE RACKSRETAIL: ±3,240 SFRESTAURANT: ±3,000 SF0102ACCESSIBLE CURB RAMP, REFER TO CIVIL DRAWINGS.PROPOSED TRANSFORMER LOCATION, PROVIDE BOLLARDS ASREQUIRED BY POWER COMPANY. REFER TO CIVIL DWGS.TRUNCATED DOMES.TRASH ENCLOSURE.BOLLARDSBIKE RACK - PER CITY STANDARD 7930BIKE LOCKERPYLON SIGN030405060708KEYNOTESMONUMENT SIGNPEDESTRIAN PATH OF TRAVELELECTRIC SWITCHGEAREV STATION (ACCESSIBLE)EV STATION (STANDARD)CLEAN AIR STALLSTRASH BINPEDESTRIAN TRELLIS0910111213141516Attachment 3Packet Page 67 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateGRADING PLANC-1CITY SPECIFICATION NO.03/16/18DATE:PROJECT TITLE:PRELIMINARY GRADING PLANSHEET TITLE:C-1SHEET NO.DESIGNED BY:A.G.DRAWN BY:A.G.CHECKED BY:L.S.APPROVED BY:SCALE:1"=20'PLAN FILE NO. / LOCATIONAttachment 3Packet Page 68 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateGRADING PLANC-2CITY SPECIFICATION NO.03/16/18DATE:PROJECT TITLE:PRELIMINARY GRADING PLAN/ SECTIONS AND DETAILSSHEET TITLE:SHEET NO.DESIGNED BY:A.G.DRAWN BY:A.G.CHECKED BY:L.S.APPROVED BY:SCALE:1"=20'PLAN FILE NO. / LOCATIONC-2Attachment 3Packet Page 69 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateUTILITY PLANC-3CITY SPECIFICATION NO.03/16/18DATE:PROJECT TITLE:PRELIMINARY COMPOSITE UTILITY PLANSHEET TITLE:SHEET NO.DESIGNED BY:A.G.DRAWN BY:A.G.CHECKED BY:L.S.APPROVED BY:SCALE:1"=20'PLAN FILE NO. / LOCATIONC-3Attachment 3Packet Page 70 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateLANDSCAPE PLANL1Attachment 3Packet Page 71 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateLANDSCAPE PLANL2Attachment 3Packet Page 72 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateFLOOR PLANA-101BUILDING-1Attachment 3Packet Page 73 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateROOF PLANA-131BUILDING-1NOTE: SEE ELEVATIONS FOR PARAPET HEIGHTSAttachment 3Packet Page 74 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateELEVATIONSA-201.1BUILDING-1EAST ELEVATIONSCALE: 3/32” = 1’-0”1TENANTSOUTH ELEVATIONSCALE: 3/32” = 1’-0”2TENANTAttachment 3Packet Page 75 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateELEVATIONSA-201.2BUILDING-1WEST ELEVATIONSCALE: 3/32” = 1’-0”3TENANTNORTH ELEVATIONSCALE: 3/32” = 1’-0”4TENANTAttachment 3Packet Page 76 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateWALL SECTIONSA-301BUILDING-1WALL SECTIONSCALE: 3/8” = 1’-0”AEAST ELEVATIONSOUTH ELEVATIONNORTH ELEVATIONWEST ELEVATIONWALL SECTIONSCALE: 3/8” = 1’-0”CWALL SECTIONSCALE: 3/8” = 1’-0”BWALL SECTIONSCALE: 3/8” = 1’-0”DDBACAttachment 3Packet Page 77 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateFLOOR PLANA-102BUILDING-2Attachment 3Packet Page 78 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateA-132ROOF PLANBUILDING-2NOTE: SEE ELEVATIONS FOR PARAPET HEIGHTSAttachment 3Packet Page 79 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateELEVATIONSA-202BUILDING-2EAST ELEVATIONSCALE: 3/32” = 1’-0”1NORTH ELEVATIONSCALE: 3/32” = 1’-0”2WEST ELEVATIONSCALE: 3/32” = 1’-0”3SOUTH ELEVATIONSCALE: 3/32” = 1’-0”4TENANTTENANTTENANTTENANTAttachment 3Packet Page 80 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateWALL SECTIONSA-302BUILDING-2EAST ELEVATIONWEST ELEVATIONNORTH ELEVATIONSOUTH ELEVATIONWALL SECTIONSCALE: 3/8” = 1’-0”AWALL SECTIONSCALE: 3/8” = 1’-0”BWALL SECTIONSCALE: 3/8” = 1’-0”CWALL SECTIONSCALE: 3/8” = 1’-0”DDBCAAttachment 3Packet Page 81 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateFLOOR PLANA-103BUILDING-3Attachment 3Packet Page 82 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateA-133ROOF PLANBUILDING-3NOTE: SEE ELEVATIONS FOR PARAPET HEIGHTSAttachment 3Packet Page 83 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateELEVATIONSA-203BUILDING-3EAST ELEVATIONSCALE: 3/32” = 1’-0”1SOUTH ELEVATIONSCALE: 3/32” = 1’-0”4WEST ELEVATIONSCALE: 3/32” = 1’-0”3NORTH ELEVATIONSCALE: 3/32” = 1’-0”2TENANTTENANT TENANTTENANTTENANTAttachment 3Packet Page 84 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateWALL SECTIONSA-303BUILDING-3WALL SECTIONSCALE: 3/8” = 1’-0”AWALL SECTIONSCALE: 3/8” = 1’-0”BWALL SECTIONSCALE: 3/8” = 1’-0”CNORTH ELEVATIONSOUTH ELEVATIONEAST ELEVATIONWEST ELEVATIONCABAttachment 3Packet Page 85 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateFLOOR PLANA-104BUILDING-4Attachment 3Packet Page 86 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateROOF PLANA-134BUILDING-4NOTE: SEE ELEVATIONS FOR PARAPET HEIGHTSAttachment 3Packet Page 87 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateELEVATIONSA-204BUILDING-4WEST ELEVATIONSCALE: 3/32” = 1’-0”1SOUTH ELEVATIONSCALE: 3/32” = 1’-0”2NORTH ELEVATIONSCALE: 3/32” = 1’-0”4EAST ELEVATIONSCALE: 3/32” = 1’-0”3TENANT TENANTTENANTTENANTTENANTTENANTTENANTTENANTAttachment 3Packet Page 88 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateWALL SECTIONSA-304BUILDING-4WEST ELEVATIONSOUTH ELEVATIONNORTH ELEVATIONEAST ELEVATIONWALL SECTIONSCALE: 3/8” = 1’-0”AWALL SECTIONSCALE: 3/8” = 1’-0”BWALL SECTIONSCALE: 3/8” = 1’-0”CWALL SECTIONSCALE: 3/8” = 1’-0”DCBDAAttachment 3Packet Page 89 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateFLOOR PLANA-105BUILDING-5Attachment 3Packet Page 90 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateROOF PLANA-135BUILDING-5NOTE: SEE ELEVATIONS FOR PARAPET HEIGHTSAttachment 3Packet Page 91 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateELEVATIONSA-205BUILDING-5WEST ELEVATIONSCALE: 3/32” = 1’-0”1SOUTH ELEVATIONSCALE: 3/32” = 1’-0”2NORTH ELEVATIONSCALE: 3/32” = 1’-0”4EAST ELEVATIONSCALE: 3/32” = 1’-0”3TENANTTENANTTENANTTENANT TENANT TENANT TENANTTENANT TENANT TENANTAttachment 3Packet Page 92 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateWALL SECTIONSA-305BUILDING-5EAST ELEVATIONNORTH ELEVATIONWEST ELEVATIONSOUTH ELEVATIONWALL SECTIONSCALE: 3/8” = 1’-0”AWALL SECTIONSCALE: 3/8” = 1’-0”BWALL SECTIONSCALE: 3/8” = 1’-0”CWALL SECTIONSCALE: 3/8” = 1’-0”DDCABAttachment 3Packet Page 93 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateFLOOR PLANA-106BUILDING-6F L O O R P L A NSCALE: 3/16" = 1'-0"1NORTHAttachment 3Packet Page 94 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateROOF PLANA-136BUILDING-6NOTE: SEE ELEVATIONS FOR PARAPET HEIGHTSAttachment 3Packet Page 95 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateELEVATIONSA-206BUILDING-6SOUTH ELEVATIONSCALE: 3/32” = 1’-0”1NORTH ELEVATIONSCALE: 3/32” = 1’-0”3WEST ELEVATIONSCALE: 3/32” = 1’-0”4EAST ELEVATIONSCALE: 3/32” = 1’-0”2Attachment 3Packet Page 96 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateWALL SECTIONSA-306BUILDING-6SOUTH ELEVATIONACDBEAST ELEVATIONWEST ELEVATIONNORTH ELEVATIONWALL SECTIONSCALE: 3/8” = 1’-0”AWALL SECTIONSCALE: 3/8” = 1’-0”BWALL SECTIONSCALE: 3/8” = 1’-0”CWALL SECTIONSCALE: 3/8” = 1’-0”DAttachment 3Packet Page 97 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateTRASH ENCLOSURE & MONUMENT SIGNTR-01TRELLIS ELEVATIONSSCALE: N.T.S.10Attachment 3Packet Page 98 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateLIGHTING PLANEPH-010.50.91.41.82.62.11.51.20.91.21.81.92.01.91.40.80.50.61.01.41.92.72.11.51.41.31.51.82.72.31.61.41.03.42.31.20.91.63.13.73.73.62.61.10.60.50.81.31.82.71.81.41.00.91.31.62.62.11.91.51.21.04.93.41.50.71.73.45.16.44.72.71.20.50.40.60.61.21.31.51.41.31.00.71.83.55.68.44.82.91.20.50.71.71.92.32.42.11.40.71.73.44.44.54.12.81.20.51.02.22.12.32.72.41.30.51.32.32.72.82.62.00.90.41.72.42.12.42.72.41.40.40.91.41.71.61.61.30.70.30.92.32.32.32.11.91.40.61.11.92.22.22.21.60.90.40.51.71.91.81.51.41.00.81.73.23.73.83.72.70.41.61.61.51.31.11.10.81.01.93.55.06.24.82.90.51.71.81.71.51.41.40.90.60.81.11.11.21.42.13.65.69.05.03.10.82.32.22.22.01.81.40.80.90.91.31.71.91.82.02.33.54.54.74.33.11.62.42.12.43.42.51.51.31.41.21.62.22.92.72.31.92.52.72.92.92.41.40.30.40.40.40.40.40.30.41.12.32.22.54.92.51.52.51.91.31.62.44.83.02.11.51.41.51.51.81.91.71.41.20.90.50.40.70.91.01.01.00.70.50.40.91.92.32.82.82.62.31.62.21.91.31.62.22.92.62.21.51.51.71.72.12.62.32.21.81.60.80.71.32.32.52.62.41.60.80.41.82.32.32.11.71.71.61.21.11.31.11.41.71.91.81.91.92.73.13.33.63.93.53.52.71.90.90.92.03.54.44.53.72.41.00.43.73.01.90.91.31.00.70.80.70.91.11.11.21.41.93.44.95.25.14.64.05.62.91.90.90.92.13.76.47.74.42.61.00.81.41.00.60.71.01.83.65.55.74.93.73.22.82.01.00.92.13.85.86.44.62.71.01.32.01.30.81.73.65.25.75.64.63.22.72.21.91.31.22.23.74.34.54.23.00.92.82.11.34.34.03.83.94.14.34.13.02.32.21.91.81.92.33.03.23.63.83.50.62.51.91.12.93.03.13.13.13.53.63.02.72.42.42.12.32.62.72.43.14.21.81.81.11.52.53.94.04.14.24.43.73.33.02.51.81.81.81.61.21.02.14.05.45.75.34.53.95.62.91.90.80.41.41.91.81.41.83.85.910.05.54.63.73.52.71.90.80.41.82.32.31.81.73.45.05.24.84.12.82.31.81.50.61.93.53.51.91.32.63.13.33.32.82.01.41.20.91.93.23.31.91.11.31.41.51.41.00.70.61.71.91.81.70.40.50.50.61.11.21.21.10.60.60.60.60.20.210.2S5 - 1S4 - 1S2 - 13S3 - 10S1 - 11S3 - 11S3 - 12S1 - 6S6 - 1S6 - 5S6 - 10S6 - 11S6 - 12S2 - 15S5 - 3S2 - 19S1 - 14S5 - 4S2 - 20S3 - 13S3 - 14S3 - 15S5 - 5StatisticsDescription Symbol Avg Min Avg/Min MaxMax/MinSITE2.2 fc 0.2 fc 11.0:1 10.2 fc51.0:1ScheduleSymbol Label QTY ManufacturerCatalog NumberDescriptionLampNumberLampsLumensper LampLLF WattageS13 Lithonia LightingDSX1 LED P2 40K T2M MVOLTDSX1 LED P2 40K T2M MVOLTLED1 8876.506 0.95 70S24 Lithonia LightingDSX1 LED P2 40K T3M MVOLTDSX1 LED P2 40K T3M MVOLTLED1 8640.771 0.95 70S36 Lithonia LightingDSX1 LED P2 40K T3M MVOLTDSX1 LED P2 40K T3M MVOLTLED1 8640.771 0.95 140S41 Lithonia LightingDSX1 LED P2 40K T4M MVOLTDSX1 LED P2 40K T4M MVOLTLED1 8707.222 0.95 70S54 Lithonia LightingDSX1 LED P2 40K LCCO MVOLTDSX1 LED P2 40K LCCO MVOLTLED1 5426.61 0.95 70S65 Lithonia LightingDSX1 LED P2 40K T3M MVOLTDSX1 LED P2 40K T3M MVOLTLED1 8640.771 0.95 280Luminaire LocationsNo. Label X YZLocationMH Tilt Orientation6 S1 -59.84 278.00 20.00 20.00 0.00 269.851 S4 126.57 -27.96 20.00 20.00 0.00 0.001 S5 -50.98 469.03 20.00 20.00 0.00 -90.003 S5 168.43 396.36 20.00 20.00 0.00 270.004 S5 205.16 71.54 20.00 20.00 0.00 0.005 S5 235.19 353.80 20.00 20.00 0.00 180.661 S6 170.87 317.03 20.00 20.00 0.00 89.74S6-1 172.44 317.04 20.00 20.00 0.00 89.74S6-2 170.88 315.47 20.00 20.00 0.00 179.74S6-3 169.31 317.02 20.00 20.00 0.00 269.74S6-4 170.87 318.60 20.00 20.00 0.00 -0.265 S6 269.81 140.10 20.00 20.00 0.00 179.74S6-1 269.82 138.53 20.00 20.00 0.00 179.74S6-2 268.24 140.09 20.00 20.00 0.00 269.74S6-3 269.80 141.66 20.00 20.00 0.00 -0.26S6-4 271.37 140.11 20.00 20.00 0.00 89.7411 S1 -61.41 24.35 20.00 20.00 0.00 -90.0014 S1 -59.84 386.65 20.00 20.00 0.00 269.8513 S2 95.04 401.57 20.00 20.00 0.00 0.0015 S2 201.15 468.75 20.00 20.00 0.00 10.7519 S2 -1.81 401.57 20.00 20.00 0.00 0.0020 S2 242.51 278.23 20.00 20.00 0.00 -90.0010 S3 292.42 480.21 20.00 20.00 0.00 179.7411 S3 -8.46 470.10 20.00 20.00 0.00 179.7412 S3 101.89 470.81 20.00 20.00 0.00 179.7413 S3 120.74 57.25 20.00 20.00 0.00 179.74S3-1 120.76 53.31 20.00 20.00 0.00 179.74S3-2 120.73 61.20 20.00 20.00 0.00 -0.2614 S3 163.70 203.63 20.00 20.00 0.00 179.74S3-1 163.72 199.68 20.00 20.00 0.00 179.74S3-2 163.68 207.57 20.00 20.00 0.00 -0.2615 S3 258.17 203.56 20.00 20.00 0.00 179.74S3-1 258.19 199.61 20.00 20.00 0.00 179.74S3-2 258.16 207.50 20.00 20.00 0.00 -0.2610 S6 182.00 141.75 20.00 20.00 0.00 179.74S6-1 182.01 140.18 20.00 20.00 0.00 179.74S6-2 180.44 141.74 20.00 20.00 0.00 269.74S6-3 182.00 143.31 20.00 20.00 0.00 -0.26S6-4 183.57 141.75 20.00 20.00 0.00 89.7411 S6 71.21 140.25 20.00 20.00 0.00 179.74S6-1 71.22 138.69 20.00 20.00 0.00 179.74S6-2 69.65 140.24 20.00 20.00 0.00 269.74S6-3 71.20 141.82 20.00 20.00 0.00 -0.26S6-4 72.78 140.26 20.00 20.00 0.00 89.7412 S6 -34.60 139.84 20.00 20.00 0.00 179.74S6-1 -34.60 138.27 20.00 20.00 0.00 179.74S6-2 -36.17 139.83 20.00 20.00 0.00 269.74S6-3 -34.61 141.40 20.00 20.00 0.00 -0.26S6-4 -33.04 139.84 20.00 20.00 0.00 89.74NORTHSCALE:SITE LIGHTING PHOTOMETRIC PLANSCALE 1"=50'Attachment 3Packet Page 99 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateIMAGE REFERENCEIM-01Attachment 3Packet Page 100 3 5 H u g u s A l l e y S u i t e 2 0 0P a s a d e n a , C a l i f o r n i a 9 1 1 0 3T : 6 2 6.5 8 3.8 3 4 8 F : 6 2 6.5 8 3.8 3 8 713215TMA03.20.2018CONCEPTUAL SUBJECT TO CHANGENKT COMMERCIAL, LLC684 HIGUERA STREET, SUITE B, SAN LUIS OBISPO, CA 93401T: 805.541.9094NWC TANK FARM ROAD & BROAD STREETSan Luis Obispo, California1#2341ST SUBMITTAL2ND SUBMITTALDescription03.20.201811.14.2018DateCOLOR MATERIAL BOARDCM-01BIKE RACKS04.25.2018BPAINT: DEC 750 BISON BEIGEBY: DUNN EDWARDSCPAINT: DEC 751 ASH GRAYBY: DUNN EDWARDSDPAINT: DE 6369 LEGENDARY GRAYBY: DUNN EDWARDSEPAINT: DEC 770 DRIFTINGBY: DUNN EDWARDSAPAINT: DET 637 SEAGULL WAILBY: DUNN EDWARDS1STANDING SEAM METAL ROOFMODEL: SCR-16 STANDING SEAMCOLOR: ZINC GRAYBY: MORIN2STOREFRONT GLASSGLASS: 1” CLEAR FLOAT GLASSBY: PPG3STOREFRONTFINISH: CLEAR ANODIZED ALUMINUMBY: ARCADIA4SIDINGMODEL: VINTAGE COLLECTIONCOLOR: CYPRESS (70%), MAHOGANY (30%)BY: AZEK5TILE BASEMODEL: COLORBODY PORCELAIN-INVOKECOLOR: MYSTIC WAY ID02, 12”x24”TILE GROUT: CUSTOM PRODUCT-335 WINTER GRAYBY: DALTILE9SPANDREL GLASSCOLOR: WARM GRAYBY: VIRACON10WOOD EAVES / KICKERS (FIRE-RETARDANT-TREATED WHERE REQUIRED)FINISH: PAINTED SEMI TRANSPARENTCOLOR: DEC 770 DRIFTING, DUNN EDWARDS12WALL SCONCEMODEL: LASER LED LAS5562 NFCOLOR: GRAYBY: US ARCHITECTURAL LIGHTING13PEDESTRIAN LIGHTSMODEL: ECLIPSE MAXI-LED, EC 811, POLE-PAA 512COLOR: GUN METALBY: LUMINIS15STUCCOFINISH: SMOOTH STEEL TROWELBY: HIGHLAND STUCCO17DECORATIVE PAVERSMODEL: CALARC LARGE SCALE NARROW MODULAR PAVERS - 12”x18”COLOR: 1413 PORCELAIN-SANDBLASTBY: STEP STONE18CONCRETE PAVINGFINISH: MEDIUM BROOM FINISH, SAW CUT LINESCOLOR: NATURAL GRAYBY: GENERAL CONTRACTOR16BOARD AND BATTEN VERTICAL SIDINGWITH 1”X3” VERTICAL BATTENSFINISH: CEDARMILL COLOR: CHESTNUT BROWNBY: HARDIE PANEL19TRASH RECEPTACLESMODEL: SDC-36COLOR: BLACKBY: VICTOR STANLEY7METAL TRELLIS FRAME / INFILLFINISH: PAINTED STEEL TUBECOLOR: DE 6369 LEGENDARY GRAY, DUNN EDWARDSBY: GENERAL CONTRACTOR8METAL EYEBROWFINISH: PAINTED STEEL TUBECOLOR: DE 6369 LEGENDARY GRAY, DUNN EDWARDSBY: GENERAL CONTRACTOR6METAL CANOPYFINISH: PAINTED STEEL TUBECOLOR: DE 6369 LEGENDARY GRAY, DUNN EDWARDSBY: GENERAL CONTRACTOR15ACORNICEFINISH: SMOOTH STEEL TROWELCOLOR: DEC 751 ASH GRAY BY: HIGHLAND STUCCO14WALL SCONCEMODEL: ECLIPSE MAXI-LED, EC 852COLOR: GUN METALBY: LUMINIS11WIRE GRIDBY: GENERAL CONTRACTORBIKE RACKSMODEL: PER CITY STANDARDSCOLOR: INDUSTRIAL HIGH GLOSS POWDER-COATEDBY: CONTRACTOR20Attachment 3Packet Page 101 WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/28/2018 6:25 PM melanie plot:11/29/2018 11:13 AM melanie ryan file:\\lenitynas\projects\westmont living\ca-san luis obispo\prelim\a0.0 cover sheet.dwg A0.0c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIACOVER SHEETA0.0 SAN LUIS OBISPO, CA ASSISTED LIVING AND MEMORY CARE FACILITY PROJECT DATA LENITY ARCHITECTURE 3150 KETTLE CT. SE SALEM, OR 97301 PHONE: (503) 399-1090 FAX: (503) 399-0565 Contact: Aaron Clark DEVELOPMENT SERVICES/ ARCHITECT: SITE ADDRESS: PROPOSED USE: APPLICANT: CIVIL ENGINEER: LANDSCAPE ARCHITECT:BRIAN LIND, LANDSCAPE ARCHITECT / LENITY ARCHITECTURE 3150 KETTLE CT. SE SALEM, OR 97301 PHONE: (503) 399-1090 FAX: (503) 399-0565 Contact: Brian Lind WESTMONT DEVELOPMENT, LP 7660 FAY AVENUE, SUITE N LA JOLLA, CA 92037 PHONE: (415) 317-9969 Contact: Michael O'Rourke Andy Plant 660 & 670 TANK FARM ROAD SAN LUIS OBISPO, CA 93401 TAX LOT# 053-421-004 RESIDENTIAL CARE FACILITY TYPE CONSTRUCTION: 5A OCCUPANCY: R2.1 BETHEL ENGINEERING 2624 AIRPORT DRIVE SANTA MARIA, CA 93455 PHONE: (805) 934-5767 Contact: Russ Garrison DRAWING INDEX CONTINUED BUILDING ELEVATIONSA6.3 L2 COURTYARD LANDSCAPE DEVELOPMENT PLAN A1.1 A1.7 LANDSCAPE DEVELOPMENT PLANL1 E1.1 SITE LIGHTING PLAN A3.1 SITE PLAN A0.0 SITE DETAILS 1ST FLOOR PLAN COVER SHEET 2ND FLOOR PLANA3.2 A6.0 BUILDING SECTIONS ELECTRICAL LANDSCAPE ARCHITECTURAL 1 OF 9 RENDERING 1 RENDERINGS 2 OF 9 3 OF 9 4 OF 9 RENDERING 2 RENDERING 3 RENDERING 4 A5.1 COLOR BOARD 5 OF 9 RENDERING 5 6 OF 9 RENDERING 6 7 OF 9 RENDERING 7 8 OF 9 RENDERING 8 9 OF 9 RENDERING 9 A5.2 IMAGE REFERENCE VICINITY MAP PROJECT LOCATION TANK FARM RD.SANTA FEBROAD ST.S. HIGUERA ST.U.S. HIGHWAY 101VIEW AT ENTRY OWNER:NKT DEVELOPMENT, LLC. 684 HIGUERA ST., SUITE B SAN LUIS OBISPO, CA 93401 PHONE: (805) 541-9004 FAX: (805) 544-0394 GEOTECHNICAL ENGINEER:BEACON GEOTECHNICAL, INC P.O. BOX 4814 PASO ROBLES, CA 93447 PHONE: (805) 239-9457 Contact: Greg McKay MICHAEL O'ROURKE ANDREW PLANT TIM DAVIES JAY NICCUM OWNER SD PHASE APPROVAL SIGNATURES: DATE DATE DATE DATE Attachment 3 Packet Page 102 MEMORY CARE WITH ASSISTED LIVING ABOVE SERVICE / DELIVERIES CONNECTION TO RETAIL PROJECT SIGN EMPLOYEE PARKINGASSISTED LIVING COURTYARD ASSISTED LIVING ASSISTED LIVING COVEREDENTRYPUBLIC ART ACCESSROADASSISTED LIVING COURTYARD MEMORY CARE COURTYARD ENTRYWAYPROPOSEDPROPERTY LINEWALKWALKT O P O F B A N K 35' S E T B A C K F R O M T O P O F B A N K PROPERTY LINE PROPERTY LINEPROPERTY LINE ASSISTED LIVING COURTYARD SHORT TERM BIKE PARKING, (6) SPACES LONG TERM BIKE PARKING, (5) SPACES, (WEATHERPROOF LOCKERS) PROPOSED TRANSFORMER LOCATION AND FUTURE GENERATOR 6' 18'59'-9"25' x 12' LOADING ZONE 16' 16'-338" 24'9'18' 7 6' 56'-8" 26' NOTE: DEMO EXISTING DWELLING AND ACCESSORY STRUCTURES c PROJECT SCOPE ASSOCIATED WITH THIS APPLICATION FACILITY VAN SEE TRACT MAP 3115 FOR PROPOSED PROPERTY LINES FLAG POLE ADJACENT DEVELOPMENT SHOWN FORREFERENCE ONLYFLOOR AREA: 6,188 SF ROOF ACCESS 52 SF TOTAL AREA: ± 6,240 SF FLOOR AREA: 4,932 SF ROOF ACCESS 50 SF TOTAL AREA: ± 4,982 SF FLOOR AREA: 4,785 SF ROOF ACCESS 50 SF TOTAL AREA: ± 4,835 SF FLOOR AREA: 3,152 SF ROOF ACCESS 53 SF TOTAL AREA: ± 3,205 SF FLOOR AREA: 7,973 SF ROOF ACCESS 53 SF TOTAL AREA: ± 8,026 SF LOADING ONLY / NO PARKINGLOADING ONLY / NO PARKINGLOADING ONLY / NO PARKING LOADING ONLY / NO PARKINGN O P A R K I N G N O P A R K I N GN O P A R K I N G N O P A R K I N GEVSTATIONEVSTATIONAMBULATORYEVSTATIONEVSTATIONEVSTATIONEVSTATIONEVSTATIONEV STATION VAN ACCESSIBLE EVSTATIONEVSTATIONEVSTATIONEVSTATIONEV STATION STANDARD ACCESSIBLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLE CLEAN AIR VEHICLE CLEAN AIR VEHICLE CLEAN AIR VEHICLE CLEAN AIR VEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEAN AIR VEHICLE CLEAN AIR VEHICLECLEANAIRVEHICLECLEANAIRVEHICLE CLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLEGAS SERVICE ELECTRICAL SERVICE 6" FIRE LINE 1 1/2" DOMESTIC WATER TELEPHONE SERVICE EV EV SCORED CONC. SCORED CONC. SCORED CONC. SCORED CONC. SCORED CONC.WALKCONNECTION TO RETAIL CONNECTION TO RETAIL WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/28/2018 6:27 PM melanie plot:11/28/2018 6:29 PM melanie ryan file:p:\westmont living\ca-san luis obispo\arch\a1.1 site plan.dwg Layout1c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIA250 50 100 150 SITE PLAN SCALE: 1" = 50' DATE: 11/29/2018 SITE DATA: PROPERTY AREA:3.80 ACRES 165,914 SQ. FT. PARKING BREAKDOWN: OPEN SPACES: EMPLOYEE SPACES: ACCESSIBLE SPACES: TOTAL SPACES: LONG TERM BIKE PARKING: SHORT TERM BIKE PARKING: TOTAL SPACES: PROJECT DATA 58 10 4 72 CURBS/PATIOS / WALKS: DRIVES / PARKING: OPEN SPACE: TOTAL PROPOSED SITE AREA BREAKDOWN: BUILDING COVERAGE: IMPERVIOUS AREA: PERVIOUS AREA: FIRST FLOOR: SECOND FLOOR: TOTAL: 67,374 SQ.FT. 66,281 SQ.FT. 133,655 SQ.FT BUILDING: 28 BED MEMORY CARE 111 UNIT ASSISTED LIVING 5 6 11 67,374 SQ.FT. 22,104 SQ.FT. 46,978 SQ.FT. 29,458 SQ.FT. 165,914 SQ.FT. (40.6%) (13.3%) (28.3%) (17.8%) (100%) 136,456 SQ.FT. 29,458 SQ.FT. VICINITY MAP SCALE: NOT TO SCALE TANK FARM RD.SANTA FEBROAD ST.S. HIGUERA ST.U.S. HIGHWAY 101SITE SITE PLANA1.1 Attachment 3 Packet Page 103 1 8'-0" 9'-01 2" STONE VENEER TO MATCH BUILDING. FINISH GRADE 3"x3" SQ. METAL LEGS W/ BASE ATTACHMENTS SIGN FONT, COLOR AND LOGO PER SIGN COMPANY AND OWNER 3" DEEP FABRICATED ALUMINUM CABINET SCALE: PROJECT SIGN 1/4" = 1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/SIGN/PROJ SIGN CONTROL JOINT COLD JOINT EXPANSION JOINT EXP. JOINT W/ CAULK AT 30'-0" OC (MAX) OR AT INTERSECTION OF ANY STRUCTURAL ELEMENTS ROUGH BROOM FINISH (TYP) SMOOTH FINISH COMPACTED SUBGRADE SCORE AT 5'-0" OC SIDEWALKS, 10'-0" OC PATIO AREAS 4" CONC WALK (TYP) ROUGH BROOM FIN SMOOTH FINISH SCALE: WALK/PATIO DETAIL (CONCRETE WALK JOINTS) 1 1/2" = 1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02520004 4" 3 8" 4" 1 2" SCALE: PARKING LOT LIGHT BASE 3/4" = 1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02850001 20 FT. #4 CU "U.F.E.R." GROUND COILED UNDER BASE 3/4" PVC CONDUIT, BURY 24" OR AS REQ. BY AUTHORITY HAVING JURISDICTION. SEE PLANS NOTES: ·COORDINATE WITH ELECTRICAL SPECIFICATIONS, SEE STRUCTURAL FOR ADDITIONAL INFORMATION ·PROVIDE SHOP DRAWINGS TO ARCHITECT FOR APPROVAL ·MIN. 24" CLEAR BETWEEN POLE BASE AND BACK OF CURB EXPOSED CONCRETE TO HAVE RUBBED FINISH, SURFACES - TOP AND SIDES 2 PIECE BASE COVER CONFIRM BOLT SIZE, PATTERN, HEIGHTS & CONDUIT REQUIREMENTS W/ POST BASE SHOP DRAWINGS FINISHED GRADE GROUND LUG INSIDE POLE FIXTURE POLE RADIUS TROWLED BULL NOSED EDGE 24" @ CURB ONLY 24" SCALE: PARKING SIGN (CALIFORNIA) NOT TO SCALE P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02840007 SHALL BE LOCATED ON A POST AT THE FRONT OF EACH PARKING SPACE. THE BOTTOM OF THE SIGN SHOULD BE A MAXIMUM HEIGHT OF SIX FEET FROM THE GROUND. IF THE PARKING SPACE IS HEADED INTO A BUILDING THE SIGN MAY BE FASTENED TO THE SIDE OF THE STRUCTURE. A STANDARD R7-8 ACCESSIBLE PARKING SIGN SHALL BE USED TO MARK EACH PARKING SPACE. MINIMUM SIGN SIZE SHALL BE 12"x18". ALL SIGNS MUST BE PERMANENTLY MOUNTED IN THE GROUND OR ON A WALL. UNAUTHORIZED VEHICLES PARKED IN DESIGNATED HANDICAPPED SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FOR PHYSICALLY DISABLED PERSONS MAY BE TOWED AWAY AT OWNERS EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT _______ OR BY TELEPHONING _______. 1" MIN. HT. LETTERS 12" R99 (CA)R100B (CA) WHITE BLUE NOTES: ONLY $250 FINE PARKING NOTES: HANDICAP SIGNAGE DETAIL SCALE: HANDICAP SIGN DETAIL CALIFORNIA NOT TO SCALE P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02840006CAL 1'-0"x1'-6"x.080 ALUMINUM HANDICAPPED PARKING SIGN. BOLT TO STEEL TUBE WITH 2-1/8" 316 STAINLESS STEEL BOLTS, NUTS AND WASHERS. SEE DETAIL 10/A1.8. $250 FINE SIGN VAN-ACCESSIBLE SIGN 2"x2"x.188 STEEL TUBE EXTENDED INTO CONCRETE FILLED PIPE 2'-0". PROVIDE WELDED WATERTIGHT CAP. PAINT P&L #6118 BLACK COFFEE PAINT PIPE BASE YELLOW PAVEMENT/SIDEWALK CONCRETE 1. HANDICAPPED PARKING SIGN SHALL CONFORM WITH CURRENT STATE AND LOCAL AND FEDERAL CODES AND REGULATIONS. 2. ALL SIGNS SHALL BE DESIGNED TO WITHSTAND 120 M.P.H. WINDLOAD. 1. WHEN HEADER CURB IS USED IN LIEU OF WHEEL STOPS, SIDEWALK ABUTTING CURB MUST BE WIDENED BY 18" SO THAT THE TOTAL SIDEWALK WIDTH IS 62", ALLOWING FOR 44" MINIMUM CLEAR ACCESSIBLE ROUTE. 2. FOR COMPLETE DETAIL OF HANDICAPPED SIGN, REFER TO DETAIL. HANDICAP SPACE STRIPING DETAIL R7-8b (CA) R99b (CA) R99 (CA) VAN ACCESSIBLE 1-1/2"R SCALE: VAN ACCESSIBLE (PARKING SIGN) NOT TO SCALE P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02840004 12" (18") FOUNDATION PER MANUFACTURES RECOMMENDATIONS (MAY VARY W/ SOILS AND WIND CONDITIONS) FIBERGLASS OR ALUMINUM TAPERED FLAGPOLE SCALE: FLAG POLE (GROUND SET CONE) NOT TO SCALE P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/10350001 3 - MOUNTING PLATES PER MANUFACTURER 5" DIA. x 35'-0" MAX. FLAG POLE AND A-BOLTS BY MANUFACTURER 24" DIA. CENTER UNDER FLAG POLE 2" CLR. (3) #3 TIES WITHIN TOP 5" OF FOOTING F.G. (4) #4 EVENLY SPACED AROUND SIDES OF FOOTING #3 TIES AT 12" o.c. F' = 2500 psi F' = 60,000 psi (#4 BARS) c y F' = 40,000 psi (#3 BARS)y 4'-0" x 8'-0" FLAG MAX. SCALE: FLAG POLE (FOOTING DETAIL) NOT TO SCALE P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/FLAGPOLE-FOOTING DETAIL FLAG POLE FOOTING PER MANUFACTURER RECOMMENDATIONS, COORDINATE REQUIREMENTS VAN 8'-0"10'-0"10'-0" NO PARKING MAX. SLOPE 1:50 AT H.C. PARKING SPACES AND AISLE SHOWN DASHED TYPICAL SYMBOL ACCESS AISLE W/ 4" PAINTED STRIPES. 12" WHITE LETTERING CROSSWALK TO RAMP ACCESSIBLE PARKING SIGN SEE 12/A1.7 TYP. COLOR EQUAL TO No. 15090 FEDERAL STANDARD 595B TWO COATS OF PAINT ON SURFACE OF PARKING AREA CENTERED ON STALL 2" WIDE WHITE STRIPING TYP. TWO COATS AT FLOOR PAINT COND. NOTE: DIMENSIONS ARE FOR THE 3'-0" SQUARE SIGN 9" SQ STEEL SIGN TO BE PROPORTIONAL 3'-0" SQ. (FLOOR PAINTED) 9" SQ. (POST MOUNTED) AC PAVEMENT AGGREGATE BASE CONC. PER PLAN 3'-0"3'-0"1'-0"1'-0" SCALE: PAVEMENT TRANSITION (PAVEMENT AND CONCRETE) 1/2"=1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02520025 NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. #4 REBAR STIRRUPS & HORIZONTAL REINFORCEMENT EMBEDMENT SLEEVE & HINGING LID LOCKABLE LID 4" Ø LOCKABLE REMOVABLE BOLLARD DOMED TOP CAL PIPE SECURITY BOLLARD IBP04040, OR APPROVED EQUAL SCALE: BOLLARD (LOCKABLE / REMOVABLE) N.T.S P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02830022 21" 21" MIN. OR TO FROST DEPTH, WHICHEVER IS GREATER BREAKAWAY LOCK 1'-6" CONFIRM BOLT SIZE, PATTERN, HEIGHTS & CONDUIT REQUIREMENTS WITH FLANGE. 3/4" PVC CONDUIT, BURY 24" OR AS REQ. BY AUTHORITY HAVING JURISDICTION. SEE PLANS. (INCLUDE EQUIPMENT GROUND CONDUCTOR PER NEC, BACK TO SOURCE) PROVIDE EQUIPMENT GROUNDING CONDUCTOR BACK TO PANEL. INSULATE AS REQUIRED BY NEC. NOTE: SEE E1.1 FOR ROUTING AND CIRCUITING. FINISHED GRADE BOLLARD LIGHT PER FIXTURE SCHEDULE. PLAN VIEW EDGE OF SIDEWALK BOLLARD CENTERED IN BASE 1'-6" SCALE: WALKWAY LIGHT BASE/POLE NTS P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/LANDSCAPE_BOLLARD NOTE: WHEN LIGHT BOLLARD OCCURES AS COLORED CONCRETE, THE BASE CONCRETE SHALL ALSO BE COLORED. 1/2" EXPANSION JOINT FILLER REFER TO SOILS INVESTIGATION REPORT FOR ADDITIONAL PAVEMENT INSTALLATION SPECIFICATIONS. SEE ARCHITECTURAL & LANDSCAPE SITE PLANS FOR DECORATIVE STAMPED PATTERN LOCATIONS IF APPLICABLE. LONGITUDINAL JOINTS MAYBE CONST JOINTS AT CONTRACTORS OPTION. TRANSVERSE CONSTR JOINTS SHALL BE INSTALLED WHENEVER THE PLACING OF CONCRETE IS SUSPENDED A SUFFICIENT LENGTH OF TIME THAT THE CONCRETE MAY BEGIN TO HARDEN. SAW CUT PER JOINT LAYOUT (SEE PLAN) NOTE: USE AT ALL FIXED OBJECTS WITHIN OR ABUTTING PAVED AREA. INSTALL 1/2"ɸ x 12"L AT 24" 0C SMOOTH STEEL DOWEL W/ GREASE AT ONE END - INSTALL WHEN REQ'D BY SOILS ENGINEER. 1/4" MAX (W/ PRE- MOLDED JOINT FILLER FLUSH W/ SURFACES) 1/4" MAX. RADIUS AT HAND FORMED JTS. 1/4" MAX. (SAWED JOINT) ISOLATION EXPANSION JOINT GENERAL NOTES: 1. 2. 3. 4. SAWED JOINT CONSTRUCTION JOINTS PREMOLDED TOOLED JOINT 1/4" SCALE: TYPICAL JOINT CONSTRUCTION (ALTERNATE CONCRETE PARKING) 1 1/2" = 1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/TYP-JOINT CONST-ALT CONC PARKING 5 2 3 4 7 6 9 8 10 11 1214 13 SCALE: ENCLOSURE (TRASH & RECYCLING) 3/16" = 1'-0"P:/WESTMONT LIVING/CA-LA MESA/DETAILS/02877021 (SEPARATE PERMIT REQUIRED) METAL OPAQUE DOOR, FIELD INSTALL GATE HINGES - TYP. OF 2 NOTE: ·CONSTRUCTION SHALL BE OF NON-COMBUSTABLE CONSTRUCTION ·ALL GATES TO BE PRE-MANUFACTURED ·GATES AND HINGES TO BE FIELD INSTALLED ·GATES WILL BE METAL AND OPAQUE (3) PAIRS OF 16 GA. RIBBED METAL GATES WITH MIN. 2" X 2" X 14" STEEL ANGLE FRAME AND DIAGONAL BRACING. CONTINUOUS WELDS ON ALL JOINTS. FIELD INSTALL GATE HINGES VENEER STONE OVER 8" CMU - PAINT INSIDE GATE POST (TYP.) 9 - 9 - 9 - 10'-0" METAL TRELLIS CURB STOP (TYP.) 15'-0" CONCRETE APRON - SEE SITE PLAN 1 1 2% SLOPE 1 1 2% SLOPE 1 1 2% SLOPE F.O.G. STORAGE TRASH RECYCLING TRASH PEDESTRIAN ACCESS 15 SCALE: BIKE DOCK (SHORT TERM BIKE PARKING) 1/8" = 1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/02830032PS NOTE: ·INSTALL PER CITY STANDARDS ·SEE CITY BICYCLE RACK DETAIL # 7930 (2) 6" x 6" x 2" DIA., FLANGE MOUNTING PLATE W/ 1" DIA. MOUNTING HOLES 36" SCALE: 1/4" - 1'-0" 36"36"36"36"36" 21' 4'-6"4'-6" PLAN SINGLE SIDE 26" R=4" 2" WHITE REFLECTIVE TAPE WRAPPED AROUND PIPE, TYP. OF 3 2" DIA. STEEL PIPE, 1/16" THICK , MIN. 3/8" DIA TAMPER RESISTANT ANCHOR, 2 3/8" LONG, TYP. (4) EA. PLATE BASE PLATE, 1/8" THICK , TYP. (SEPARATE PERMIT REQUIRED) CANE BOLTS (TYP.) 6" O.H. 6" O.H. (3) SETS 16 GA. RIBBED METAL GATES WITH MIN. 2" X 2" X 14" STEEL ANGLE FRAME AND DIAGONAL BRACING. CONTINUOUS WELDS ON ALL JOINTS. FIELD INSTALL GATE HINGES ELEVATION - FRONT SCALE: 3/16" = 1'-0" ELEVATION - END SCALE: 3/16" = 1'-0" NOTE: ·CONSTRUCTION SHALL BE OF NON-COMBUSTABLE CONSTRUCTION ·ALL GATES TO BE PRE-MANUFACTURED ·GATES AND HINGES TO BE FIELD INSTALLED ·GATES WILL BE METAL AND OPAQUE METAL OPAQUE DOOR, FIELD INSTALL GATE HINGES. TYPICAL OF (2) METAL TRELLIS METAL TRELLIS SCALE: TRASH AND RECYCLING ENCLOSURE 1/8" = 1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/TRASHELEV VENEER STONE OVER 8" CMU - PAINT INSIDE GATE POST GATE POST (TYP.)WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 11:20 AM samt plot:11/28/2018 6:28 PM melanie ryan file:p:\westmont living\ca-san luis obispo\arch\a1.7 site details.dwg A1.7c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIASITE DETAILSA1.7 Attachment 3 Packet Page 104 2154215424602448 2436 246024422436 24422436 244224422436 244224602460 244224482460KITCHEN FRZ. DRY STOR. ELEC WALK-IN COOLER FCR MECH R.R. ELEV. EQ.ELEVATORBEAUTY BEAUTY CHARTS MEDS MAIL MEDS RECEPT. DIRECTOR EXECUTIVE DISCOVERY WORK SPACE SALESSALES CHARTS RSD L.D. HALL R.R. ACTIVITY R.R. LINEN MDF DINING ROOM COVERED POOL 14' x 25'-6" 4'-0" MAX. DEPTH STOR. AL HOUSE- KEEPING FITNESS 18 x 37 "MAIN STREET" WARM KIT. LIN. STOR CHAIR STOR THEATER / CHAPEL 23 SEATS (21 FIXED, 2 H'CAP) ASSISTED LIVING COURTYARD STOR. DINING SITTING ELEC OFFICE SEATING R.R. DYE. HOUSE KEEPING ACTIVITY 24 x 45 STOR. OFFICE BISTRO 23 x 25 SHWR. STOR. MECH. R.R. R.R R.R MCMCMC MC MC MC MC C MC EMER. FOOD STOR. MAINT. STOR. AB STOR. 1055 011031 1040 LIN./ STOR ELEV. CORRIDOR CORRIDOR 1093 CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR HALL CORRIDOR CORRIDOR CORRIDOR CORRIDORCORRIDORWAIT STAFF STAIR-3 FIRE SHUTTER FIRE SHUTTER FIRE SHUTTER STAIR-2 SEATING ELEVATOR 03 C BBC C A A B B A B A W/DA A A ABBBBB B ELEVATOR EQUIPMENT ROOM MCMCMCMC MC MCMC MC MC MC MC MC MCMCMCMCMCMCMCMC B CORRIDOR CORRIDOR ELECT. RM. B MEMORY CARE COURTYARD B ASSISTED LIVING COURTYARD ASSISTED LIVING COURTYARD 119 1042 117 115 113 111 109 107 103 101 02 1088 1023 1089 1037 1038 1027 1026 1087 1021 1020 28 27 26 25 24 23 22 21 10851086 1018 1016 101710191030 1029 1039 1032 102104 106 141 139138 140 110 1091 1102 1090 112 116 1041 121 123 125 127 129 131 1095 128 130 132 134 133 135 136 1066 1043 1068 1096 137 1050 1049 1048 1047 1046 1044 1097 1053 1052 1057 1060 1054 1064 1062 1042 1063 1061 1059 1065 1001 1080 1058 1051 1007 1004 02 04 06 08 09 10 11 12 13 14 1008 1009 1103 15 16 07 05 10820301 1002 1003 17 1012 1011 1013 1010 18 1084 19 20 1014 1015 1081 1005 1006 1083 1094 1098 OFFICE B.O.D 10451067 EXIT PASSAGEWAY 1077 10781079 A B B B B DYE. 1056 1092 CORRIDOR STAIR-1 1101 1028 EXIT PASSAGEWAY EXIT PASSAGEWAY B.O.H. B.O.H.WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 10:26 AM samt plot:11/28/2018 6:32 PM melanie ryan file:p:\westmont living\ca-san luis obispo\arch\a3.1 1st floor.dwg A3.1c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIA1ST FLOOR SCALE: 1/16" = 1'-0" "A" Studio Units = 32 "B" One Bedroom Units = 68 "C" Two Bedroom Units = 11 TOTAL = 111 TOTAL UNIT MIX "A" Studio Units = 10 "B" One Bedroom Units = 19 "C" Two Bedroom Units = 4 UNIT MIX - LEVEL ONE = 33 "MC" Studio Units = 28"MC" Studio Units = 28 GRAND TOTAL = 139 Level One = 67,374 sq. ft. BUILDING AREA Level Two = 66,281 sq. ft. TOTAL = 133,655 sq. ft.1ST FLOORPLANA3.1 Attachment 3 Packet Page 105 STOR ELEVATORR.R. ELEVATOR ELEC.12 20972085 2093 2103 ELEVATOR 3 ELEVATOR EQUIPMENT ROOM ELECT. RM. 2009 269 2010 267 265 2087 266 262 263 261 259 249 260 2085 2102 247 245 2007 2008 2006 237 235 233 231 229 227 225 223 2084 221 217 215 220 218 216 228230232 2005 238 240 242 2004 2003 208206204 2001 2002 2081 213211209207205203201 2080 299297295293291289287 285 283 281 2089 2090 279 277 2088 275 273 271 278 280 282 284 257 255 253 251 252 254 256 292 2011 294 296 243 241 239 2012 244246248250 2096209120922082208320862101 20942095WINDOWS TO BELOW / FIRE SPRINKLER CURTAIN AL HOUSE- KEEPING SEATING ELEV LOBBY KITCHEN HOOD CHASE OPEN TO BELOW IDF / STOR. ADA LAUNDRY IDF / STOR. SEATING OPEN TO BELOW C B A B B B B A OFFICE/ TRAINING DATA IDF OPEN TO BELOW B B SEATING B "MAIN STREET"CORRIDOR CORRIDORCORRIDORCORRIDOR CORRIDORCORRIDOR CORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDOR STAIR 2 STAIR 3 SEATING B A B B B B AB C B B B B BAAAAAACBB B B A AABA A A BB B B B AA C CORRIDOR CORRIDORSEATING C BBC C A B B B A A BBB B B B B B B B CORRIDOR CORRIDOR B B CORRIDOR DECK B A STAIR 1 B B WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 10:25 AM samt plot:11/28/2018 6:33 PM melanie ryan file:p:\westmont living\ca-san luis obispo\arch\a3.2 2nd floor.dwg A3.2c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIA2ND FLOORPLANA3.2 2nd FLOOR SCALE: 1/16" = 1'-0" "A" Studio Units = 22 "B" One Bedroom Units = 49 "C" Two Bedroom Units = 7 TOTAL LEVEL TWO = 78 UNIT MIX - LEVEL TWO BUILDING AREA LEVEL TWO = 66,281 sq. ft. Attachment 3 Packet Page 106 Attachment 3Packet Page 107 Attachment 3Packet Page 108 KITCHENFRZ.DRY STOR.ELECWALK-INCOOLERFCRMECH R.R.ELEV. EQ.ELEVATORBEAUTYBEAUTYCHARTSMEDSMAILMEDSRECEPT.DIRECTOREXECUTIVEDISCOVERYWORK SPACESALESSALESCHARTSRSDL.D.HALLR.R.ACTIVITY R.R.LINENMDFDINING ROOMCOVEREDPOOL14' x 25'-6"4'-0" MAX.DEPTHSTOR.AL HOUSE-KEEPINGFITNESS18 x 37"MAIN STREET"WARMKIT.LIN.STORCHAIRSTORTHEATER / CHAPEL23 SEATS (21 FIXED, 2 H'CAP)ASSISTEDLIVINGCOURTYARDSTOR.DININGSITTINGELECOFFICESEATINGR.R.DYE.HOUSEKEEPINGACTIVITY24 x 45STOR.OFFICEBISTRO23 x 25SHWR.STOR.MECH.R.R.R.RR.RMCMCMCMCMCMCMCCMCEMER.FOODSTOR.MAINT.STOR.ABSTOR.10550110311040LIN./STORELEV.CORRIDORCORRIDOR1093CORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORHALLCORRIDORCORRIDORCORRIDORCORRIDORCORRIDORWAIT STAFFSTAIR-3STAIR-2SEATINGELEVATOR03CBBCCAABBABAAAAABBBBBBELEVATOREQUIPMENTROOMMCMCMCMCMCMCMCMCMCMCMCMCMCMCMCMCMCMCMCMCBCORRIDORCORRIDORELECT. RM.BMEMORYCARECOURTYARDBASSISTED LIVINGCOURTYARDASSISTED LIVINGCOURTYARD119104211711511311110910710310102108810231089103710381027102610871021102028272625242322211085108610181016101710191030102910391032102104106141139138140110109111021090112116104112112312512712913110951281301321341331351361066104310681096137105010491048104710461044109710531052105710601054106410621042106310611059106510011080105810511007100402040608091011121314100810091103151607051082030110021003171012101110131010181084192010141015108110051006108310941098OFFICEB.O.D10451067EXITPASSAGEWAY107710781079ABBBBDYE.10561092CORRIDORSTAIR-111011028EXITPASSAGEWAYEXITPASSAGEWAYB.O.H.B.O.H.12'-1"1'-634"10'-1"15'-034"29'-5"12'-1"1'-634"10'-1"25'-034"31'-714"SUITE CORRIDOR ELEV. EQUIP.KITCHEN DINING SITTING PATIO SEATING T.O. PARAPET T.O. PLATE T.O. SLAB SOIL CORRIDOR WAIT STAFF CORRIDOR DECKCORRIDOR T.O. PARAPET T.O. PLATE T.O. SLAB 155.00' 150.00' 160.00' 155.00' 150.00' 160.00' ENTRY DRIVEWAY 161.2' FFE 161.2' FFE T.O. PARAPET TANK FARM ROAD SUITE SUITE SUITE SUITE SUITE SUITE DINING CORRIDORCORRIDOR CORRIDOR MEMORY CARE COURTYARD 12'-1"1'-634"10'-1"26'-434"T.O. PARAPET T.O. PLATE T.O. SLAB T.O. SHEATHING T.O. PLATE 12'-1"1'-634"10'-1"26'-434"T.O. PARAPET T.O. PLATE T.O. SLAB T.O. SHEATHING T.O. PLATE 155.00' 150.00' 160.00' 161.2' FFE 161.2' FFE ASSISTED LIVING COURTYARD ASSISTED LIVING COURTYARD 12'-1"1'-634"10'-1"26'-434"ROAD (DRIVEWAY) ℄ SUITE SUITE SUITE SUITE SUITE SUITE SUITE SUITE CORRIDOR CORRIDOR CORRIDOR CORRIDOR T.O. PARAPET T.O. PLATE T.O. SLAB T.O. SHEATHING T.O. PLATE 12'-1"1'-634"10'-1"26'-434"T.O. PARAPET T.O. PLATE T.O. SLAB T.O. SHEATHING T.O. PLATE 155.00' 150.00' 160.00' CREEK 161.2' FFE 161.2' FFE ASSISTED LIVING COURTYARD ASSISTED LIVING COURTYARD WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 10:51 AM michaelb plot:11/28/2018 6:34 PM melanie ryan file:p:\westmont living\ca-san luis obispo\arch\a6.0 building sections.dwg A6.0c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIABUILDINGSECTIONSA6.0SECTIONA A6.0 SCALE: 3/32" = 1'-0" SECTION KEY PLAN NOT TO SCALE SECTIONB A6.0 SCALE: 3/32" = 1'-0" B B AA Attachment 3 Packet Page 109 SCALE : D NORTH ELEVATION 1/16"=1'-0" SCALE : C EAST ELEVATION 1/16"=1'-0" SCALE : B SOUTH ELEVATION 1/16"=1'-0" SCALE : A WEST ELEVATION 1/16"=1'-0" A D 1 2 3 4 5 6 7 = STANDING SEAM METAL ROOFING COLOR: SW 2844 ROYCROFT MIST GRAY ROOF = PARAPET ROOF HEIGHTS PER ELEVATIONS = VINYL FRAMED INSULATED WINDOWS W/ TRIM COLOR: BEIGE = BOARD AND BATT SIDING SIDING SIDING WINDOW = PTAC COLOR: TO MATCH ADJACENT BUILDING COLOR, TYP. PTAC = STUCCO FINISH (MAIN BODY) MFR: OMEGA COLOR: SW 9117 URBAN JUNGLE SIDING = HARDIPLANK HORIZONTAL SIDING COLOR: SW 7507 STONE LION MFR: SHERWIN WILLIAMS KEY NOTES 8 9 10 = FASCIA TRIM COLOR: SW 2844 ROYCROFT MIST GRAY = DECORATIVE CORBEL MFR: TRIM FASCIA = CULTURED STONE VENEER: EASTERN MOUNTAIN LEDGE COLOR: PROVO CANYON GREY COLOR: WESTERN RED CEDAR: STAMPED / ALUMAWOOD 11 = TRELLIS STONE COLOR: SW 7040 SMOKEHOUSE C B ELEVATION KEY PLAN SCALE: N.T.S. 4' 8'0 16' 4' 8'0 16' 4' 8'0 16' 4' 8'0 16' KITCHEN FRZ. DRY STOR. ELEC WALK-IN COOLER FCR MECH R.R. ELEV. EQ. BEAUTY BEAUTY CHARTS MEDS MAIL MEDS RECEPT. DIRECTOR EXECUTIVE DISCOVERY WORK SPACE SALESSALES CHARTS RSD L.D. HALL R.R. ACTIVITY LINEN MDF DINING ROOM COVERED POOL 14' x 25'-6" 4'-0" MAX. DEPTH STOR. AL HOUSE- KEEPING FITNESS 18 x 37 "MAIN STREET" WARM KIT. LIN. STOR CHAIR STOR THEATER / CHAPEL 23 SEATS (21 FIXED, 2 H'CAP) ASSISTED LIVING COURTYARD STOR. DINING SITTING ELEC OFFICE SEATINGR.R. DYE. HOUSE KEEPING ACTIVITY 24 x 45 STOR. OFFICE BISTRO 23 x 25 SHWR. STOR. MECH. R.R. R.R R.R MCMCMC MC MC MC MC C MC EMER. FOOD STOR. MAINT. STOR. AB STOR. 1055 1031 1040 LIN./ STOR ELEV. CORRIDOR CORRIDOR 1093 CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR CORRIDOR HALL CORRIDOR CORRIDOR CORRIDOR CORRIDOR WAIT STAFF STAIR-3 STAIR-2 SEATING ELEVATOR 03 C BBC C A A B B A B A A A A ABBBBB B ELEVATOR EQUIPMENT ROOM MCMCMCMC MC MCMC MC MC MC MC MC MCMCMCMCMCMCMCMC B CORRIDOR CORRIDOR ELECT. RM. B MEMORY CARE COURTYARD B ASSISTED LIVING COURTYARD ASSISTED LIVING COURTYARD 119 1042 117 115 113 111 109 107 103 101 02 1088 1023 1089 1037 1038 1027 1026 1087 1021 1020 28 27 26 25 24 23 22 21 10851086 1018 1016 101710191030 1029 1039 1032 102104 106 141 139138 140 110 1091 1102 1090 112 116 1041 121 123 125 127 129 131 1095 128 130 132 134 133 135 136 1066 1043 1068 1096 137 1050 1049 1048 1047 1046 1044 1097 1053 1052 1057 1060 1054 1064 1062 1042 1063 1061 1059 1065 1001 1080 1058 1051 1007 1004 02 04 06 08 09 10 11 12 13 14 1008 1009 1103 15 16 07 050301 1002 1003 17 1012 1011 1013 1010 18 1084 19 20 1014 1015 1081 1005 1006 1083 1094 1098 OFFICE B.O.D 10451067 EXIT PASSAGEWAY107710781079 A B B B B DYE. 1056 1092 CORRIDOR STAIR-1 1101 1028 EXIT PASSAGEWAY EXIT PASSAGEWAY B.O.H. B.O.H. D 12'-1"1st FLR.13'-734"2nd FLR.10'-1"23'-834"1'-63 4" 6 559 288971346 553 443 610108 29 10 842121223 46 8512 4 2 2 2 6 6 6 4 2 6 2 2444 10 4 6 5 2 4 8 6 2 5 2 3 2 4 2 26 5 2 6 4 6 6 8 4 8 9 1 5 2 6 1 5 8 5 2 2 3 5 2 3 2 5 2 3 2 6 2 8 5 2 2 5 8 2 2 8 2 5 6 2 8 5 2 3 2 4 6 4 3 410 10 4 6 3 38 3 6 3 6 6 4 612'-1"1'-634"10'-1"T.O. PLATE T.O. SHEATHING T.O. PLATE T.O. PLATE 12'-1"1'-634"10'-1"T.O. PLATE T.O. SHEATHING T.O. PLATE T.O. PLATE 12'-1"1'-634"10'-1"T.O. PLATE T.O. SHEATHING T.O. PLATE T.O. PLATE 12'-1"1'-634"10'-1"T.O. PLATE T.O. SHEATHING T.O. PLATE T.O. PLATE 12'-1"1'-634"10'-1"T.O. PLATE T.O. SHEATHING T.O. PLATE T.O. PLATE 12'-1"1'-634"10'-1"T.O. PLATE T.O. SHEATHING T.O. PLATE T.O. SLAB12'-1"1'-634"10'-1"T.O. PLATE T.O. SHEATHING T.O. PLATE T.O. SLAB 5222155 777 7 3 6 10 7 6 454 82 2 2 3 5 2 2 2 5 2 6 4 9 5 1 2 4 2 3 2 8 4 2 METAL AWNING ASSEMBLY (BALCONY AND WINDOW) 1" = 1'-0"P:/WESTMONT LIVING/CA-SAN LUIS OBISPO/DETAILS/MTL AWNING (2) 1/4" x 5" LAG BOLT AT 6" SQUARE PLATE WELD TO ROD PER MANUF. TYP. 1"x3" HSS SUPPORT WELDED TO PLATE A 6 12 A WINDOW / DOOR RECESSED TRIM EDGE OF WINDOW TRIM 2" CLR OF STUCCO CORNER 15 A7.2a SIM STANDING SEAM METAL ROOFING HSS CAP ENDS HSS SUPPORTS AT 2'-0" O.C. 2"x2" HSS SUPPORT BEAM SEE ELEVATIONS FOR LOCATION AND PLAN FOR OPENING SIZE STANDING SEAM METAL ROOFING OVER WRB WINDOW / DOOR AS OCCURS T.O. PLATE T.O. PLATE BIDDER DESIGN AWNING TO SUPPORT SELF WEIGHT + 20PSF ROOF LIVE LOAD CONTINUOUS VERTICAL 6x6 POST LOCATED AT CENTERLINE OF AWING SUPPORT BIDDER DESIGNED 3" VERTICAL GRAIN T&G EXPOSED AT UNDERSIDE STAIN TO MATCH TRELLIS CONTINUOUS 1x3 LEDGER WITH 1/4" X 5" LAG BOLTS AT 12" O.C. SIM. 6" 11 4" CLR. TYP SECTION 'A'ELEVATION 'B' PLAN VIEW A ELEV. 6'-3" (TYP.) OR 11'-2" PER PLAN ELEV. VERTICAL GRAIN T&G EXPOSED AT UNDERSIDE STAIN TO MATCH TRELLIS 1x2 HSS AT 2'-0" O.C. (TYP.) CONTUINUOUS 3x1 HSS LEDGER STANDING SEAM METAL ROOFING 1x2 HSS AT 2'-0" O.C. (TYP.) 2x2 HSS SUPPORT 3x1 HSS LEDGER NORTH FACING SIDE OF AWNING TO HAVE A SHADE (WEST ELEVATION ONLY) 1 1 A6.3 TYP. 4 11 11 EXTERIORBUILDING ELEVATIONSA6.3WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 10:31 AM melanie plot:11/29/2018 10:55 AM melanie ryan file:p:\westmont living\ca-san luis obispo\bldgs\elevations-mcf.dwg Layoutc2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIAAttachment 3 Packet Page 110 3018'-6"25'18'-6"18'-6"25'18'-6"18'-6"30'18'-6"LOADING DOCKP L A N T E RLANDSCAPED AREAPROPERTY LINEPROPERTY LINE9' TYP 9' TYP P L A N T E R FLOOR AREA: 7,973 SF ROOF ACCESS 53 SF TOTAL AREA: ± 8,026 SFSWITCHGEAREVSTATIONEVSTATIONAMBULATORYEVSTATIONEVSTATIONCLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEANAIRVEHICLECLEAN AIR VEHICLE CLEAN AIR VEHICLECLEANAIRVEHICLECLEANAIRVEHICLE 6'-6"GAS SERVICE ELECTRICAL SERVICE 6" FIRE LINE 1 1/2" DOMESTIC WATER TELEPHONE SERVICE 30'13'11'7'12'30' 2 8 'WALK12 7 TRASH ENCLOSURE SERVICE / DELIVERIES CONNECTION TO RETAIL PROJECT SIGN 2 2 3 9 6 6 ASSISTED LIVING COURTYARD COVEREDENTRYPUBLIC ART ACCESSROADASSISTED LIVING COURTYARD MEMORY CARE COURTYARD PROPOSEDPROPERTY LINEWALKWALK15 T O P O F B A N K 35' S E T B A C K F R O M T O P O F B A N K PROPERTY LINEPROPERTY LINE ASSISTED LIVING COURTYARD SHORT TERM BIKE PARKING, (6) SPACES PROPOSED TRANSFORMER LOCATION AND FUTURE GENERATOR 25' x 12' LOADING ZONE NOTE: DEMO EXISTING DWELLING AND ACCESSORY STRUCTURES c FACILITY VAN SEE TRACT MAP 3115 FOR PROPOSED PROPERTY LINES FLAG POLE 10 6.4 7.5 9.5 12.5 12.3 11.0 8.6 9.9 13.7 12.8 12.0 10.0 7.9 10.5 9.8 9.4 8.0 0.7 1.0 1.6 2.5 2.7 2.7 2.9 2.4 1.9 1.8 2.1 2.7 2.8 2.3 2.9 1.8 1.9 1.9 2.0 2.1 1.8 2.5 2.8 1.7 2.0 2.0 1.3 4.3 10.2 9.6 4.0 4.8 12.5 10.7 3.7 3.3 9.0 12.3 4.9 5.2 10.9 6.9 6.7 5.4 6.2 2.3 5.2 6.4 4.2 4.0 2.8 3.7 0.8 1.7 4.6 1.5 3.6 11.7 11.3 4.6 13.0 1.5 1.0 1.3 4.9 6.0 8.9 5.2 4.9 2.3 1.5 1.9 11.2 7.3 0.9 5.0 0.5 5.6 1.4 3.6 7.1 6.7 2.2 2.3 2.4 0.8 4.0 1.3 4.4 0.8 4.3 1.2 5.0 0.4 1.6 7.6 1.2 1.7 2.3 2.4 1.9 1.9 1.9 1.8 1.5 1.9 1.0 1.7 2.4 3.8 4.2 3.0 2.3 2.1 2.2 2.4 3.6 4.3 3.2 2.1 2.3 2.0 2.3 3.1 4.4 4.4 3.3 3.1 3.0 3.9 4.7 3.8 2.8 2.6 2.7 3.2 4.3 4.0 2.9 3.4 6.3 3.7 5.4 0.4 0.6 0.8 0.9 0.9 0.9 1.1 1.1 1.1 1.2 1.1 1.1 1.0 1.0 0.6 0.8 1.0 1.2 1.4 1.4 1.5 1.4 1.5 1.5 1.4 1.4 1.5 1.4 1.4 1.2 1.0 0.9 0.7 0.7 0.9 1.2 1.7 2.2 2.2 2.2 1.9 1.7 1.8 1.7 1.9 2.3 2.3 2.1 1.7 1.3 1.1 0.8 0.6 0.6 0.8 1.0 0.7 1.0 1.5 2.3 2.7 2.7 2.8 2.3 1.9 1.8 2.0 2.5 2.8 2.7 2.8 2.2 1.5 1.2 0.9 0.8 0.8 1.1 1.5 1.9 2.1 2.5 2.7 2.4 2.8 2.4 1.9 1.8 2.0 2.6 2.8 2.7 2.8 2.4 1.7 1.4 1.1 0.9 0.8 1.2 1.9 2.6 2.8 3.2 4.0 4.0 3.0 2.0 1.9 2.0 2.6 2.9 1.9 3.0 2.5 1.9 2.8 3.8 4.5 4.4 3.4 2.5 1.7 1.2 1.3 1.9 2.4 2.5 2.4 2.1 1.9 1.9 1.9 2.2 2.6 2.6 2.6 2.2 4.0 3.1 2.6 2.1 1.6 1.2 1.1 1.4 1.8 1.9 2.0 1.9 1.8 1.9 1.9 1.9 2.0 1.9 2.0 1.9 3.1 2.5 2.1 1.6 1.2 0.9 1.2 1.6 1.9 1.9 1.8 1.8 2.0 2.0 1.7 1.6 1.6 1.8 2.1 2.0 1.6 1.2 1.2 1.9 2.5 3.8 4.5 3.2 3.2 4.6 4.0 2.6 2.2 1.9 1.8 2.5 2.3 2.1 1.6 1.4 1.9 2.7 4.0 4.6 3.7 3.7 4.7 4.2 2.9 2.3 2.0 1.9 2.9 2.8 2.9 2.7 2.2 2.2 2.5 3.2 4.0 3.6 2.4 2.2 3.3 2.7 3.0 2.7 1.7 1.4 2.3 2.9 3.5 4.1 4.2 4.3 4.3 4.2 4.1 3.7 3.0 2.6 2.1 1.8 1.8 2.1 2.6 2.6 2.6 2.2 2.2 2.5 3.0 3.3 3.4 3.2 2.7 2.3 1.5 2.6 3.7 4.1 4.1 2.8 1.4 1.6 2.3 3.1 3.8 4.1 4.5 4.4 4.4 4.5 4.2 3.9 3.3 2.6 2.2 2.0 1.9 2.0 2.0 1.9 1.9 1.8 2.0 2.4 2.8 3.3 3.3 3.3 2.8 2.1 1.6 1.7 4.3 4.8 4.6 3.4 2.1 1.7 2.3 2.9 3.2 3.6 4.0 3.9 3.9 3.9 3.5 3.2 2.8 2.2 2.0 3.6 5.0 4.6 3.3 1.5 1.5 1.5 1.6 1.9 2.2 2.3 2.1 2.1 2.0 1.6 1.4 4.3 3.6 2.6 1.4 3.4 3.0 3.1 4.4 3.6 3.2 4.2 3.1 2.1 1.9 4.3 4.0 1.5 1.2 1.2 1.1 1.2 1.2 1.0 0.9 0.8 0.9 0.9 4.8 3.7 2.1 1.0 7.4 4.0 3.8 7.7 3.9 3.0 8.5 4.7 2.2 2.4 4.1 3.6 1.9 1.3 1.3 1.5 1.3 1.2 0.8 0.8 0.5 0.6 0.9 7.1 3.3 1.4 0.7 4.0 1.6 0.9 0.5 1.7 1.3 0.8 0.4 3.2 1.8 0.8 0.3 4.0 1.3 0.5 0.3 1.5 0.7 0.4 0.3 1.4 1.4 1.0 0.5 3.9 2.9 1.2 0.5 6.0 2.1 0.7 0.4 2.0 1.0 0.7 0.5 1.8 1.7 1.0 0.6 4.8 2.3 1.0 0.6 3.7 1.6 1.0 0.7 1.9 1.4 1.0 2.0 1.8 1.4 0.9 2.4 2.0 1.6 2.6 2.9 2.4 4.0 3.5 4.4 3.9 3.6 3.3 2.7 2.4 0.9 1.8 1.8 1.9 2.1 2.1 3.4 2.5 1.5 1.7 2.3 2.7 2.7 2.7 2.2 2.0 3.2 2.7 3.2 3.6 3.1 2.6 2.4 2.5 2.7 3.2 3.7 0.7 0.8 2.6 2.8 2.4 1.9 2.1 2.6 3.6 3.8 3.7 3.6 3.5 3.6 3.9 3.6 3.2 3.1 3.1 3.3 3.6 3.5 2.8 2.4 2.0 2.8 3.3 3.3 3.4 3.0 2.8 2.9 3.2 3.6 3.7 4.0 4.0 4.0 4.4 4.2 4.8 4.8 3.6 2.6 2.4 2.2 1.9 1.2 1.3 1.7 2.5 2.8 2.7 2.9 2.4 2.1 2.3 2.8 3.3 3.6 3.8 4.0 4.0 4.0 4.0 3.8 3.8 3.6 3.5 3.5 3.6 3.6 3.4 3.1 2.6 2.1 1.0 1.6 2.2 2.5 2.5 2.7 2.5 2.3 2.4 2.7 3.0 3.0 3.4 3.5 3.4 3.3 3.7 4.4 4.5 3.6 2.5 2.2 1.9 1.6 1.4 1.4 1.7 2.2 2.7 2.6 2.6 2.2 2.0 2.0 2.3 2.7 2.7 2.9 3.2 3.1 3.1 3.2 2.9 2.9 2.9 2.7 2.8 2.9 2.7 2.5 2.4 1.9 1.5 0.6 1.0 1.2 1.2 1.2 1.4 1.5 1.4 1.5 1.6 1.6 1.6 1.9 2.2 2.3 2.5 3.1 3.8 4.0 3.1 2.3 1.7 1.4 1.3 1.2 1.2 1.3 1.6 1.9 1.8 1.8 1.6 1.4 1.5 1.5 1.5 1.3 1.4 1.7 1.8 1.8 1.6 1.4 1.5 1.6 1.6 1.6 1.5 1.2 1.1 1.2 1.0 0.8 SA5 SA4 SA2 SA4 SA4 SA4 SA4 SA4 SA4 SA4 SA2 SA2 SA2 SA5 SA5 SA5 SB SBSSSS SF SW1 SW1 SW1 SW1 SW1 SW1 SW3 SW3 SW3 SW1 SW2 SW1 SW1 SW1 SW1 SW1 SW1 SW3 SW3 SW3 SW3 SW1 SW1 SW1 TYPE SC TYP. OF 24 SB SB SB SB SB SB WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 11:21 AM samt plot:11/28/2018 6:46 PM melanie ryan file:p:\westmont living\ca-san luis obispo\elec\lighting\site-lighting.dwg E1.1c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIA150 30 60 120 SCALE: 1" = 30' SITE LIGHTING PHOTOMETRIC PLAN Statistics Description Symbol Avg Max Min Max/Min Avg/Min ENTRY 10.1 fc 13.7 fc 6.4 fc 2.1:1 1.6:1 PARKING 2.3 fc 7.7 fc 0.3 fc 25.7:1 7.7:1 SIDEWALK 4.1 fc 13.0 fc 0.4 fc 32.5:1 10.3:1 Schedule Label Mount Height Quantity Manufacturer Catalog Number Description Lamp Number Lamps Filename Lumens Per Lamp Light Loss Factor Wattage SA2 20'4 Lithonia Lighting DSX0 LED P6 40K T2M MVOLT HS DSX0 LED P6 40K T2M MVOLT with houseside shield LED 1 DSX0_LED_P6_40K _T2M_MVOLT_HS.ie s 13054 0.95 134 SA4 20'8 Lithonia Lighting DSX0 LED P6 40K TFTM MVOLT HS DSX0 LED P6 40K TFTM MVOLT with houseside shield LED 1 DSX0_LED_P6_40K _TFTM_MVOLT_HS.i es 12465 0.95 134 SA5 20'4 Lithonia Lighting DSX0 LED P6 40K T5M MVOLT DSX0 LED P6 40K T5M MVOLT LED 1 DSX0_LED_P6_40K _T5M_MVOLT.ies 16575 0.95 134 SB 3'6"8 Lithonia Lighting DSXB LED 16C 530 40K SYM D-SERIES BOLLARD WITH 16 4000K LEDS OPERATED AT 530mA AND SYMMETRIC DISTRIBUTION LED 1 DSXB_LED_16C_53 0_40K_SYM.ies 2397 0.95 28 SC Underside of Ceiling 33 COOPER LIGHTING - - HALO SLD612940WH HALO 6 INCH SURFACE LED DOWNLIGHT LED 1 SLD612940WH.ies 1000 0.95 14.8 SF 1'1 Lithonia Lighting DSXF1 LED P1 40K NSP DSXF1 LED P1 40K NSP LED 1 DSXF1_LED_P1__4 0K_NSP.ies 2876 0.95 21 SS 1'2 Lithonia Lighting DSXF1 LED P1 40K MFL DSXF1 LED P1 40K MFL LED 1 DSXF1_LED_P1__4 0K_MFL.ies 2692 0.95 21 SW1 9'34 WAC Lighting WS-W20506 Wall Mount LED 1 W20506- C14100003_IESNA 2002.ies 866 0.95 16.8 SW2 11'3 WAC Lighting DS-WS05-F35S-WT Wall Mount Tube LED 1 DS-WS05-F35S- WT.IES 1453 0.95 23.8 SW3 14'9 Lithonia Lighting WST LED P3 40K VF MVOLT WST LED, Performance package 3, 4000 K, visual comfort forward throw, MVOLT LED 1 WST_LED_P3_40K_ VF_MVOLT.ies 6609 0.95 50 Spill onto RZ 0.0 fc 0.3 fc 0.0 fc NA NA 20'2'-0"18'-0"ELECTRICALSITEPLANE1.1 Attachment 3 Packet Page 111 EVSTATIONEVSTATIONAMBULATORYEVATIONCLEANAIRVEHICLECLEANAIRVEHICLEECLEAN AIR VEHICLE CLEAN AIR VEHICLECLEANAIRVEHICLECLEANAIRVEHICLE GAS ELEC 6" FI 1 1/2" TELE WALKMEMORY CARE WITH ASSISTED LIVING ABOVE 12 7 TRASH ENCLOSURE SERVICE / DELIVERIES CONN TO RE PROJECT SIGN 2 2 3 9 6 6 ASSISTED LIVING COURTYARD ASSISTED LIVING ASSISTED LIVING COVEREDENTRYPUBLIC ART ACCESSROADASSISTED LIVING COURTYARD MEMORY CARE COURTYARD ENTRYWAYPROPOSEDPROPERTY LINEWALKWALK15 T O P O F B A N K 35' S E T B A C K F R O M T O P O F B A N K PROPERTY LINE PROPERTY LINEPROPERTY LINE ASSISTED LIVING COURTYARD SHORT TERM BIKE PARKING, (6) SPACES PROPOSED TRANSFORMER LOCATION AND FUTURE GENERATOR 25' x 12' LOADING ZONE NOTE: DEMO EXISTING DWELLING AND ACCESSORY STRUCTURES c FACILITY VAN SEE TRACT MAP 3115 FOR PROPOSED PROPERTY LINES FLAG POLE 10 SOIL BERM NOTE- REFER TO SHEET L2 FOR COURTYARD PLANTING DETAILS. SYMBOLS BOTANICAL NAME COMMON NAME PLANTING LEGEND QUANTITY SIZE WUCOLS I North-Central Coast TREES 15 Low24" box Std. Cassia leptophylla Gold Medallion Tree 16 Low24" box Std. SHRUBS 5 LowArbutus unedo 'Compacta' Compact Strawberry Tree 15 gal. 28 LowCoprosma petriei 'Verde Vista' Creeping Coprosma 1 gal. 40 LowMahonia repens Creeping Mahonia 1 gal. 12 LowCarpenteria californica Bush Anemone 5 gal. 25 LowCeanothus gloriosus 'Anchor Bay' California Lilac 5 gal. 45 LowRhamnus californica 'Mound San Bruno' Coffeeberry 5 gal. 59 LowMyrtus communis 'Compacta' Compact Myrtle 5 gal. 25 LowJuniperus scopulorum 'Skyrocket' Skyrocket Juniper 15 gal. 76 LowRhaphiolepis indica 'Ballerina' Indian Hawthorn 5 gal. 83 ModerateRosa floribunda 'Iceberg' Iceberg Rose 5 gal. 74 LowSalvia greggii 'Coral' Coral Autumn Sage 5 gal. 13 LowPhlomis fruticosa Jerusalem Sage 5 gal. GRASSES/PERENNIALS 6 ModerateAspidistra elatior Cast Iron Plant 5 gal. 68 LowLavandula angustifolia 'Twickel Purple' Dwarf English Lavender 1 gal. 91 LowPennisetum alopecuroides 'Little Bunny' Little Bunny Fountain Grass 1 gal. 3 ModeratePhormium 'Maori Queen' Hybrid New Zealand Flax 5 gal. 482 LowRosmarinus officin. 'Huntington Carpet' Trailing Rosemary 1 gal. 31 LowMuhlenbergia capillaris Pink Muhly 1 gal. GROUND COVERS 1. All landscape areas shall be irrigated with an automatic irrigation system utilizing SMART Technology with weather sensor. 2. Provide 2" min. layer of organic mulch in all planting beds. 3. Courtyard plant materials shown on Sheet L2 are not included in Planting Legend. NOTES 95 LowEuonymus japon.'Microphyllus Variegata' Variegated Box-leaf Euonymus 5 gal. 7 Very LowRomneya coulteri Matilija Poppy 5 gal. Lagerstroemia 'Natchez' Natchez Hybrid Crape Myrtle STREET TREES Tristaniopsis laurina Water Gum 8 Moderate15 gal. Std. Artificial Turf DuPont Forever Lawn or equal Very Low 1. Provide a 36" high screen of cars between parking areas and street with an evergreen hedge/shrubs masses, wall or berm. Parking areas are screened with a 36" high evergreen hedge and shrub masses. SPECIFIC PLAN CRITERIA 2. Provide screening of electrical transformers and equipment with evergreen shrubs or berm. All equipment is screened with evergreen shrubs. 3. Parking Lot Trees: A. Use single tree species at end planter islands with second tree species between islands as an option. Two tree species have been used in the parking lot planters. B. Provide "Orchard Style" planting in parking lot at a rate of 1 tree / 4 parking spaces. The parking lot does not have multiple rows of parking but an Orchard Style tree planting approach has been applied where feasible. 73 spaces / 4= 18 required trees, 31 trees are proposed* * additional trees proposed to achieve 50% shade requirement at 10 years. 32 LowHelictotrichon sempervirens Blue Oat Grass 1 gal.WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 11:29 AM brianl plot:11/28/2018 6:44 PM melanie ryan file:p:\westmont living\ca-san luis obispo\prelim\landscape.dwg L1c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIA150 30 60 90 L1 Landscape Development Plan SCALE: 1" = 30' DATE: 1/23/2018, rev. 3/7/2018, rev. 11/29/2018 EXP. 11 - 30 - 18 TOTAL SITE LANDSCAPE AREA = 29,458 s.f. TOTAL IRRIGATED LANDSCAPE AREA = 31,332 s.f. MAXIMUM ANNUAL APPLIED WATER ALLOWANCE (MAAWA) MAAWA (gallons)= (ETo) x (.62) x ((0.45 x LA) + (0.3 x SLA)) ESTIMATED ANNUAL APPLIED WATER USE (ETo) x (PF-Kc) x (HA) x (.62) / (IE)= EAAWU (HYDROZONE) (43.80) x (.62) x ((0.45 x 31,332) + (0.3 x 0)) = MAAWA 382,883 gals. EAAWU TOTAL (EATAWU): 287,015 gals. EATAWU 287,015 gals. is less than MAAWA 382,883 gals. (43.80) x (0.2) x (19,048) x (.62) / (.81) = 127,720 gals. EAAWU (LOW HYDROZONES) (43.80) x (0.5) x (8299) x (.62) / (.81) = 139,116 gals. EAAWU (MODERATE HYDROZONES) (43.80) x (0.9) x (152) x (.62) / (.75) = 4953 gals. EAAWU (HIGH HYDROZONES) NOTE- ETo used for this site in San Luis Obispo, CA = 43.80 (43.80) x (0.05) x (1959) x (.62) / (1.0) = 2660 gals. EAAWU (VERY LOW- ARTIFICIAL TURF) RIGHT-OF-WAY LANDSCAPE AREA = 1874 s.f.LANDSCAPEDEVELOPMENTPLANL1 COURTYARD 1 COURTYARD 2 COURTYARD 3 (43.80) x (0.2) x (1874) x (.62) / (.81) = 12,566 gals. EAAWU (LOW HYDROZONES- R.O.W.) Attachment 3 Packet Page 112 Rhaphiolepis indica 'Ballerina' Indian Hawthorn, 27-5 gal. Lavandula angustifolia 'Munstead' Dwarf English Lavender, 7-1 gal. Clytostoma callistegioides, 1-15 gal. Lavender Trumpet Vine, train up trellis post Rosa floribunda 'Iceberg' Iceberg Rose, 9-5 gal. Trachelospermum jasminoides Star Jasmine (shrub form) 6-1 gal. Ophiopogon japonicus Mondo Grass 41-1 gal. Aspidistra elatior Cast Iron Plant, 6-5 gal. Nandina domestica 'Gulf Stream' Gulf Stream Heavenly Bamboo, 3-5 gal. Magnolia grandiflora 'Little Gem' Little Gem Magnolia, 1-24" box Heuchera 'Lime Rickey' Lime Rickey Coral Bells 23-1 gal. Agapanthus africanus 'Peter Pan White' Dwarf White Lily-of-the-Nile, 24-1 gal. Nandina domestica 'Gulf Stream' Gulf Stream Heavenly Bamboo, 4-5 gal. COURTYARD 3 LIV Annual Flowers 4" pots @ 12" o.c. Phormium 'Maori Queen' Hybrid New Zealand Flax, 1-15 gal. Rosmarinus officinalis 'Tuscan Blue' Tuscan Blue Rosemary, 2-5 gal. Rhaphiolepis indica 'Ballerina' Indian Hawthorn, 6-5 gal. Rhaphiolepis indica 'Ballerina' Indian Hawthorn, 8-5 gal. Woodwardia fimbriata Giant Chain Fern, 1-5 gal. Nandina domestica 'Gulf Stream' Gulf Stream Heavenly Bamboo, 9-5 gal. Pittosporum tobira 'Dwarf Variegata' Dwarf Variegated Tobira, 8-5 gal. COURTYARD 2 Syringa patula 'Miss Kim' Miss Kim Lilac, 1-15 gal. Syringa patula 'Miss Kim' Miss Kim Lilac, 1-15 gal. Hebe 'Veronica Lake' Veronica Lake Hebe, 6-5 gal. Escallonia 'Fradesii' Pink Escallonia, 5-5 gal. Agapanthus africanus 'Peter Pan White' Dwarf White Lily-of-the-Nile, 7-1 gal. Rosa x. 'Noala' Coral Carpet Rose, 3-5 gal. Rosa x. 'Noala' Coral Carpet Rose, 4-5 gal. Agapanthus africanus 'Peter Pan White' Dwarf White Lily-of-the-Nile, 17-1 gal. Heuchera 'Lime Rickey' Lime Rickey Coral Bells 10-1 gal. Nandina domestica 'Gulf Stream' (Typical symbol) Gulf Stream Heavenly Bamboo, 7-5 gal. Aspidistra elatior Cast Iron Plant, 2-5 gal. Aspidistra elatior Cast Iron Plant, 2-5 gal. Buddleia davidii 'Blue Chip Jr.' Blue Chip Jr. Butterfly Bush, 1-5 gal. Anigozanthos 'Tequila Sunrise' Tequila Sunrise Kangaroo Paw, 2-1 gal. Rosmarinus officinalis 'Roman Beauty' Roman Beauty Rosemary, 1-1 gal. COURTYARD 1 WESTMONT OF SAN LUIS OBISPODATE SHEET REVISED DATE save:11/13/2018 11:29 AM brianl plot:11/28/2018 6:44 PM melanie ryan file:p:\westmont living\ca-san luis obispo\prelim\landscape.dwg L2c2018 Lenity Architecture11/29/18 SAN LUIS OBISPO, CALIFORNIAL2 Courtyard Landscape Plans SCALE: 1" = 8' Courtyard 1Courtyard 2 Courtyard 3 EXP. 11 - 30 - 18 COURTYARDLANDSCAPE PLANL2 DATE: 1/23/2018, rev. 3/7/2018, rev. 11/29/2018 Attachment 3 Packet Page 113 Attachment 3Packet Page 114 Attachment 3Packet Page 115 Attachment 3Packet Page 116 Attachment 3Packet Page 117 Attachment 3Packet Page 118 Attachment 3Packet Page 119 Attachment 3Packet Page 120 Attachment 3Packet Page 121 Attachment 3Packet Page 122 EVSTATIONAMBULATORY CLEANAIRVEHICLECLEAN AIR VEHICLE CITY SPECIFICATION NO.03/16/18DATE:PROJECT TITLE: WESTMONT ASSISTED LIVING PRELIMINARY GRADING PLAN SHEET TITLE:C-1WSHEET NO.DESIGNED BY:A.G.DRAWN BY:A.G.CHECKED BY:L.S.APPROVED BY:SCALE:1"=20'PLAN FILE NO. / LOCATIONAttachment 3Packet Page 123 CITY SPECIFICATION NO.03/16/18DATE:PROJECT TITLE: WESTMONT ASSISTED LIVING PRELIMINARY GRADING PLAN/ SECTIONS AND DETAILS SHEET TITLE:SHEET NO.DESIGNED BY:A.G.DRAWN BY:A.G.CHECKED BY:L.S.APPROVED BY:SCALE:1"=20'PLAN FILE NO. / LOCATIONC-2WAttachment 3Packet Page 124 BROAD STREETTANK FARM ROADLOADING ONLY / NO PARKING2A2C2 B 2 D··Attachment 3Packet Page 125 Attachment 3Packet Page 126 NWC TANK FARM & BROAD STREET SAN LUIS OBISPO, CA CONSTRUCTION PHASING PLAN 12/18/18 8 SCALE: 1”=30’ WESTMONT SENIOR LIVING BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 BUILDING 6 PHASE 2A PHASE 3A & 3B PHASE 1PHASE 1BROAD STREETTANK FARM ROAD PHASE 2B CONSTRUCTION PHASING PLAN PHASE 1: MASS GRADING OF 10 ACRES • INCLUDES CREEK CROSSING FOR INDUSTRIAL WAY ROAD EXTENSION • EXCLUDES GRADING IN WETLAND AREA ON NORTH-EAST CORNER OF THE RETAIL SITE PHASE 2A: WESTMONT SITEWORK PHASE 2B: PIP’S REQUIRED FOR WESTMONT TO OPERATE • TANK FARM ROAD WIDENING IN FRONT OF WESTMONT • FRONTAGE IMPROVEMENTS (SIDEWALK & LANDSCAPE) ALONG WESTMONT PARCEL ON TANK FARM ROAD • INDUSTRIAL WAY CONNECTION (SESLOC ROAD CREEK CROSSING) & TRAFFIC SIGNAL MODIFICATIONS ON TANK FARM ROAD • WOONERF • LANDSCAPE WETLAND MITIGATION AREA ON WESTMONT PARCEL PHASE 3A: RETAIL SITEWORK • INCLUDES GRADING IN WETLANDS AT NORTH EAST CORNER OF PARCEL PHASE 3B: PIP’S • BROAD STREET DRIVEWAY REMOVAL AT SESLOC • FRONTAGE IMPROVEMENT (SIDEWALK & LANDSCAPE) ON BROAD STREET FRONTAGE AND TANK FARM RETAIL • ROAD WIDENING ON BROAD STREET & TANK FARM ROAD ALONG RETAIL FRONTAGE Attachment 3 Packet Page 127 Meeting Date: June 13, 2018 Item Number: 1 2sz PLANNING COMMISSION AGENDA REPORT SUBJECT: Conceptual policy review of two proposed projects on a site designated in the General Plan Land Use Element as the Broad Street and Tank Farm Road Site Special Focus area. The proposed projects include a retail shopping center with 49,000 square feet (NKT Development), and assisted living facility of 133,655 square feet with 111 assisted living suites and 28 memory care studio units (Westmont Living) PROJECT ADDRESS: 3985 Broad Street & BY: Brian Leveille, Senior Planner 660 Tank Farm Road Phone Number: 781-7166 e-mail: bleveille@slocity.org FILE NUMBER: SPEC-1482-2018 FROM: Doug Davidson, Deputy Director RECOMMENDATION: Determine that the proposed projects conform with Special Focus Area General Plan Land Use policies and direct staff to continue with the review of the proposed entitlements. SITE DATA Applicants Nicholas Tompkins, NKT Development Westmont Development LP Representative Carol Florence, Oasis Associates Zoning Community Commercial with Special Focus Overlay (C-C-SF), Business Park with Airport Area Specific Plan overlay (BP-SP) and Conservation Open Space with the Airport Area Specific Plan overlay C/OS- SP) General Plan Community Commercial, Business Park, & Conservation Open Space Site Area Retail Shopping – 5.28 acres Assisted Living – 4.79 acres Environmental Status Conceptual review feedback is not subject to CEQA review. An initial study will be prepared to evaluate potential impacts pursuant to CEQA. 1.0 BACKGROUND The Broad Street at Tank Farm Road Site is designated in the General Plan Land Use Element as Special Focus Area. General Plan policy guidelines for The Broad Street at Tank Farm Road Site state the site is to mixed use and pay attention to the connectivity, safety and comfort of bicycle and pedestrian circulation. Attachment 4 Packet Page 128 SPEC-1482-2018 (3985 Broad Street and 660 Tank Farm Road ) June 13, 2018 Page 2 Staff held a pre-application meeting with the applicant on June 22, 2017. Staff provided feedback to the applicant and their representative noting concerns on the configuration, uses, and connectivity (Pre- application letter, Attachment 1). While some minor changes have been made to the site plan of the retail commercial center, staff is requesting that the Planning Commission provide feedback on the overall consistency of the project with Special Focus Area General Plan objectives for the site prior to proceeding with detailed review and environmental analysis of the project. 2.0 SITE DESCRIPTION The project site is located at the northwest corner of Broad Street and Tank Farm Road within the Airport Area Specific Plan (AASP). Surrounding uses include SESLOC Federal Credit Union to the north, a mobile home park to the west, Marigold Shopping Center to the east, and Mindbody offices and the Edna Valley Market and Gas Station to the south. Orcutt Creek is located along the western boundary of the project site. The majority of the site (8.5 acres) is zoned Community-Commercial with Special Focus Area Overlay (C-C-SF). The Business Park (BP-SP) zoned portion of the site is approximately 1-acre (Figure 1, below). 4.0 PROJECT DESCRIPTION The proposed project includes a retail shopping center and assisted living facility. The proposed retail shopping center development comprises 5.28 acres of the project area and consists of an anchor retail grocer space and additional buildings for retail/restaurant use totaling 45,269 square feet (Attachment 3, retail center plan sheets). The assisted living facility would occupy 4.79 acres of the westerly portion of Figure 1. Project site and vicinity Project site Attachment 4 Packet Page 129 the project site (assisted living facility plan sheets, Attachment 4). The assisted living facility is two- stories with 133,655 square feet and comprised of 111 assisted living suites and 28 memory care beds (Attachment 2, applicant project narrative). 5.0 DISCUSSION Staff is requesting early high-level comments from the Planning Commission to determine if the proposed retail center and assisted living facility can be considered consistent with the overall General Plan objectives for the site (LUE 8.13). The key issues for consideration relate to the mix of uses on the project site. Policy 8.13 says that the site will be “used as a mixed-use site” and will provide for a “mix of uses” but does not definitively provide direction on any required residential component. The proposed project does include a mix of uses, although each property is proposed to be developed individually. The site was rezoned Community Commercial (C-C), which allows for mixed-use projects but does not require the inclusion and integration of residential uses. The fundamental policy consideration may be the extent to which the residential care facility1 can function as an integrated horizontal mixed-use project with the retail development. The Commissions’ discussion and feedback should be focused on whether the project is headed in the right direction to implement Special Focus Area policies, or if modifications are needed to bring the project into alignment with General Plan objectives for the site. The proposed uses and the functionality as a mixed-use project are especially important considerations. The proposed assisted living facility is not an allowed in the C-C zone as a stand-alone use. If the assisted living facility is not sufficien tly integrated with the retail component to be classified overall as a mixed-use project, the zoning code would not allow this use. 6.0 ATTACHMENTS 1. Pre-application letter 2. Applicant project narrative 3. Project Plans – Retail Commercial (NKT Development) 4. Project Plans – Assisted Living (Westmont) 1 Residential Care Facilities are classified as residential uses in Zoning Code section 17.22 (Table 9) Attachment 4 Packet Page 130 CityofSanLuisObispo, CouncilAgenda, City Hall, 990PalmStreet, SanLuisObispo Minutes Planning Commission Regular Meeting Wednesday, June 13, 2018 CALL TO ORDER A Regular Meeting of the San Luis Obispo Planning Commission was called to order on Wednesday, June 13, 2018 at 6:00 p.m. in the Council Chamber, located at 990 Palm Street, San Luis Obispo, California, by Chair Fowler. ROLL CALL Present : Commissioners Hemalata Dandekar, Robert Jorgensen, John McKenzie, Nicholas Ostebur, Vice-Chair Charles Stevenson, and Chair John Fowler. Absent: None Staff : Community Development Director Michael Codron, Community Development Deputy Director Davidson, Assistant City Attorney Jon Ansolabehere, Recording Secretary Summer Aburashed. Pledge of Allegiance Chair Fowler led the Pledge of Allegiance. PUBLIC COMMENTS ON ITEMS NOT ON THE AGENDA None CONSENT AGENDA – CONSIDERATION OF MINUTES 1.Approval of the minutes of the April 11, April 25, May 9, and May 23, 2018 Planning Commission meeting. ACTION: MOTION BY COMMISSIONER JORGENSEN, SECOND BY COMMISSIONER OSTERBUR, CARRIED 7-0-0 to approve the minutes of April 11, 2018. ACTION: MOTION BY COMMISSIONER STEVENSON, SECOND BY COMMISSIONER MC KENZIE, CARRIED 7-0-0 to approve the minutes of April 25, 2018, with a correction to show that Commissioner Dandekar arrived at 6:30 P.M. Attachment 4 Packet Page 131 Planning Commission Meeting Minutes June 13, 2018 Page 2 of 5 ACTION: MOTION BY COMMISSIONER DANDEKAR, SECOND BY COMMISSIONER MC KENZIE, CARRIED 7-0-0 to approve the minutes of May 9, 2018. ACTION: MOTION BY COMMISSIONER MC KENZIE, SECOND BY COMMISSIONER OSTERBUR, CARRIED 7-0-0 to approve the minutes of May 23, 2018. PUBLIC HEARINGS 2.3985 Broad St. and 660 Tank Farm. Conceptual policy review of two proposed projects on a site designated in the General Plan Land Use Element as the Broad Street and Tank Farm Road Site Special Focus area. The proposed projects include a retail shopping center with 49,000 square feet (NKT Development), and assisted living facility of 133,655 square feet with 111 assisted living suites and 28 memory care studio units. Case #: SPEC-1482-2018; C/OS- SP and C-C-SF zone; NKT Development, and Westmont Development, applicants. Chair Fowler, Vice Chair Stevenson and Commissioner McKenzie indicated that they had ex-parte communication with the applicant and/or the applicant’s representative. Senior Planner, Brian Leveille, presented the staff report and responded to Commission inquiries. Applicant Representative, Carol Florence, provided background on the project, discussed surrounding uses, and provided an update on Airport Land Use Commission review. Applicant, Nick Tompkins, discussed his experience in commercial development and how this project could relate to surrounding uses such as Mind Body. Public Comments Kathy Borland James Lopes Chair Fowler closed the public hearing. The following Commission comments were made by the Commission: Commissioner Stevenson noted the assisted living use is badly needed in our community and that independent living apartments as part of this project would help make the connection with mixed use and the residential component should be more integrated with the commercial use. Commissioner Dandekar noted she was a member of the LUCE task force and that her recollection of the intended use of the site was an energized node that would cater to young people that work in this area. Commissioner Ostebur agreed with Commissioner Dandekar’s comments noting that housing should be a main objective. Attachment 4 Packet Page 132 Planning Commission Meeting Minutes June 13, 2018 Page 3 of 5 Commissioner Wulkan stated he thought the project looked like two separate projects. He stated that although the assisted living use is needed, the intent for mixed use is for housing and jobs to be in proximity and the proposal is not consistent with mixed-use intent. He also noted concerns with compatibility in terms of design of the commercial loading areas being near the windows of the assisted living facility. Commissioner McKenzie supported the idea of a stronger independent living component with better connectivity and noted that if workforce housing could be approved by the ALUC it is well suited for the area. He echoed comments on compatibility and concerns with circulation and traffic. Commissioner Jorgensen stated concerns with the commercial loading zone’s proximity to the assisted living facility. He noted this corner will be useful for commercial development with all of the pending housing to be constructed in the area. He stated a desire to bring pedestrians into the area with a larger plaza for restaurant uses and said he did not see the synergy between the assisted living use and the retail center and there should be more space for pedestrians. Commissioner Stevenson stated going higher would allow for more density if allowed by the ALUC and residential should be shifted farther north away from Tank Farm Road. Commissioner Dandekar stated that this is a major corridor and the corner could be more of a statement to make the corner more urban and function as a gateway. Vice Chair Stevenson again noted the community strongly needs the assisted living use and memory care facilities and that he is OK with the uses if there is more independent living and that he supports Commissioner Jorgensen’s comments that there should be more plazas and the existing plaza is somewhat auto dominated. He stated the mix of uses could work with independent living included and better incorporation into the site plan. Chair Fowler stated there may be too much parking for the assisted living facility and that with height it may be possible to get residential in the commercial component. He stated there is some opportunity for the uses to work as noted by Commissioner Stevenson and asked Community Development Director, Michael Codron if there was adequate direction from the Commission. Michael Codron discussed the Special Focus Area policy for the area regarding the mix of uses on the site and that it would be helpful in the future to provide more information on some of the existing and pending projects in the area. Michael Codron summed up his understanding of the Commission’s feedback noting he did not hear strong direction that the corner commercial component absolutely had to include residential and that the proposed mix of uses could be appropriate but that the two uses need to communicate and that the retail component needs to be able to add to the vitality of the area. Commissioner Stevenson stated there needs to be a better connection between uses and that with this project it needs an independent living apartments component. Attachment 4 Packet Page 133 Planning Commission Meeting Minutes June 13, 2018 Page 4 of 5 Commissioner Dandekar stated there should still be opportunity to keep the assisted living facility but still accommodate residences on upper floors in the retail component. Commissioner Stevenson summarized that he didn’t think the Commission was commenting the uses were the issue, but the site plan needs revisions. RECESS: The Commission recessed at 7:25 p.m. and reconvened at 7:30 p.m. with all Commissioners present. BUSINESS ITEMS 3.Zoning Regulations Update. Review of the Draft Zoning Regulations Update focused on implementing the policies and programs of the Land Use and Circulation Elements (LUCE). The update also incorporates best practices, addresses deficiencies identified by staff in working with the document daily, and reformats the document; Negative Declaration of Environmental Impact under CEQA; Case #: GENP-0327-2017; City-wide; City of San Luis Obispo, applicant. Deputy Director Doug Davidson, and Associate Planner Kyle Bell presented the staff report and responded to Commission inquiries. Chair Fowler opened the public hearing. Public Comments Kathy Borland Bob Lucas Emily Ewer Stephen Peck Dave Juhnke Tom Swem Jim Duffy James Lopes Save Our Downtown Charlene Rosales, San Luis Obispo Chamber of Commerce Sarah Flickinger Sandra Rowley Russell Brown Devin Gallagher Chair Fowler closed the public hearing. RECESS: The Commission recessed at 8:54 p.m. and reconvened at 9:03 p.m. with all Commissioners present. The following comments were provided: Attachment 4 Packet Page 134 Planning Commission Meeting Minutes June 13, 2018 Page 5 of 5 Article 1: No changes. Article 5: Page 416 –17.92.040 A.– change 50% to 75% or more Article 7: Change references to City’s CEQA Guidelines to State’s CEQA Guidelines Article 8 No changes. Motion by Commissioner McKenzie, Second by Vice Chair Stevenson to continue the item to the June 14 Adjourned meeting. Motion carried on a voice vote of 7-0-0. COMMENT AND DISCUSSION 4. Agenda Forecast – No report provided. ADJOURNMENT The meeting was adjourned at 9:30 p.m. The next Adjourned Regular meeting of the Planning Commission is scheduled for Thursday, June 14, 2018 at 6:00 p.m., in the Council Chamber, 990 Palm Street, San Luis Obispo, California. APPROVED BY THE PLANNING COMMISSION: 07/11/2018 Attachment 4 Packet Page 135 ARCHITECTURAL REVIEW COMMISSION REPORT 1.0 PROJECT DESCRIPTION AND SETTING Retail shopping center with six buildings and a total of approximately 49,000 square feet and assisted living facility with 144 living units, support, and administrative space in 133, 656 square feet. The site is mostly vacant with one single family residence. General Location: The northwest corner of Broad Street and Tank Farm Road within the Airport Area Specific Plan (AASSP) Present Use: No current use Zoning: Community Commercial with Special Focus Overlay (C-C-SF) AASP: Business Park with Airport Area Specific Plan Overlay (BP-SP), and Conservation Open Space with Specific Plan Overlay (C/OS-SP) General Plan: Community Commercial with Special Focus Overlay, Business Park, and Conservation and Open Space Surrounding Uses: East: Marigold Shopping Center/Vons West: Hidden Hills Mobile Home Park North: Sesloc Federal Credit Union South: Mindbody, Edna Valley Market & Gas Environmental: An initial study to assess potential environmental effects is currently being prepared. 2.0 PROPOSED DESIGN Architecture: The commercial center is a more agrarian, rural architectural style. The assisted living facility is a more contemporary collection of various design elements taken from the adjoining commercial center and surrounding commercial neighborhoods. Design details: The commercial center consists of seven (7) detached buildings combining heavy shed FROM: Doug Davidson, Deputy Director BY: David Watson, Contract Planner PROJECT ADDRESS: 3985 Broad Street and FILE NUMBER: ARCH - 1486-2018 660 Tank Farm Road APPLICANT: NKT Development and REPRESENTATIVE: Carol Florence, Oasis Associates Westmont Development LP For more information contact: David Watson at 805-704-8728 or dave@watsonplanning.us Meeting Date: October 15, 2018 Item Number: 2 Item No. 1 Attachment 5 Packet Page 136 roofs, one-story storefront massing that includes windows on the pedestrian level and upper wood/board and batten siding leading to the roof elements. The assis ted living facility includes an eclectic mix of vertical and horizontal siding and stucco exterior walls, featuring some wooden and stone pilasters and columns, with use of trellis, canopies, awnings and arbor entry and shade elements intermixed within the various exterior treatments, along with flat, standing seam and parapet roofs with some exaggerated overhangs. Materials: Commercial center includes a standing seam roof, storefront glazing with anodized aluminum frames, metal trellis and canopy features, stucco and vertical board and batten siding. The assisted living facility materials include vertical board and batten and horizontal lap siding, stone and wood columns, use of heavy timber beams and roof kickers, vinyl framed windows with trim, decorative corbels and facia treatments, and standing seam metal roofs. Colors: Colors for both projects follow subdued natural earth tone themes. The commercial center has a more uniform application of colors on all seven buildings including board and batten and shed roof elements at the corner entries to the buildings, use of stucco exteriors between these corner features, and accenting these long walls with trellis and canopy fea tures. 3.0 FOCUS OF REVIEW: Review for consistency with the Community Design Guidelines and Airport Area Specific Plan (AASP) design standards. The ARC’s action will take the form of a recommendation to the Planning Commission. Staff has included excerpts from the Community Design Guidelines and AASP Design Guidelines for reference and links are provided below for full documents: Community Design Guidelines: https://www.slocity.org/home/showdocument?id=2104 Airport Area Specific Plan: http://www.slocity.org/home/showdocument?id=4294 Perspective view of northwest corner of Tank Farm and Broad Attachment 5 Packet Page 137 4.0 COMMUNITY DESIGN GUIDELINES/DISCUSSION ITEMS Features Staff notes Site Design Fits the site Appears in scale and compatible with the context of surrounding development in the area; Functions well Pedestrian access provided along frontages. ARC could discuss adequacy of internal circulation within the retail project and connections to the assisted living portion of project; CDG 3.2 Transitions Buildings are located along landscaped frontages at corner; AASP Goals 5.1 & 5.3. ARC should discuss if streetscape edge and adequacy of support for pedestrian activity. Building Design Proportions Includes some variation in height of walls and articulation; CDG 3.2.D.4. Interest Complementary use of materials and colors for each project with some variation in application Details Trellis, corbels, roof articulation Colors/Materials provides a restrained earth tone pallete that appears complementary with natural tones and surroundings; AASP Goal 5.14 Landscaping Single variety of street tree proposed. ARC could discuss adequacy of plantings that evoke natural planting patterns. CDG 3.2.F & AASP “Ruralness” Design Guidelines. Entry View of Proposed Assisted Living Facility Attachment 5 Packet Page 138 5.0 (a) JUST THE FACTS – ASSISTED LIVING FACILITY Site Details Proposed Allowed/Required Setbacks – Front (to Tank Farm) 16’-0” 0’ Setbacks – Side / Rear 56’-4” / 59’-9” 0’ / 0’ Height of Structures 31’-7” 35’ Max Building Coverage (footprint) 67,374 (32.3%) 75% of 208,652 sq ft Max Floor Area Ratio (FAR) 98,473 sq ft (0.47 FAR) 2.0 Density Units (DU/Est’d Persons) 144 DU / 166 persons Generally 1,020 persons per ALUC density calculations. City standard up to 36 DU/ac. Total # Parking Spaces 70 standards proposed in AASP amendments Total # Bicycles 0 Standards proposed in AASP amendments 5.0 (b) JUST THE FACTS – RETAIL SHOPPING CENTER Site Details Proposed Allowed/Required Setbacks – Front (Tank Farm / Broad) 15’-3” / 18’-10” 0’ Setbacks – Side / Rear 65’-5” / 18’-0” 0’ / 0’ Maximum Height of Structures varies 24’-0” to 34’-0” 35’ Max Building Coverage (footprint) 49,269 (21.4%) 75% of 230,355 sq ft Max Floor Area Ratio (FAR) 49,269 sq ft (0.21 FAR) 2.0 Density Units (DU/Est’d Persons) na DU / 331 persons See above Combined project at 497 persons or 49% of allowed Total # Parking Spaces 217 Standards proposed in AASP amendments Total # Bicycles 32 Standards proposed in AASP amendments 6.0 ACTION ALTERNATIVES 6.1 Recommend the Planning Commission find the project consistent with Community Design Guidelines and AASP Design Guidelines as proposed or with recommended conditions. 6.2 Continue review of the project with direction to the applicant and staff. 6.3 Recommend the Planning Commission find the project inconsistent with Community Design Guidelines and AASP Design Guidelines. 7.0 ATTACHMENTS 7.1 Project Plans 7.2 Excerpts from Guidance Documents Attachment 5 Packet Page 139 Minutes ARCHITECTURAL REVIEW COMMISSION Monday, October 15, 2018 Regular Meeting of the Architectural Review Commission CALL TO ORDER A Regular Meeting of the Architectural Review Commission was called to order on Monday, October 15, 2018 at 5:01 p.m. in the Council Hearing Room, located at 990 Palm Street, San Luis Obispo, California, by Vice-Chair Amy Nemcik ROLL CALL Present: Commissioners Richard Beller, Brian Rolph (5:04), Angela Soll, Christie Withers, and Vice-Chair Amy Nemcik Absent: Commissioner Micah Smith and Chair Allen Root Staff: Deputy Director Doug Davidson, Senior Planner Shawna Scott, Consulting Planner Dave Watson, and Recording Secretary Summer Aburashed. Other staff members presented reports or responded to questions as indicated in the minutes. PUBLIC COMMENT ON ITEMS NOT ON THE AGENDA None End of Public Comment-- APPROVAL OF MINUTES 1. Consideration of Minutes of the Regular Architectural Review Commission Meeting of August 27, 2018, September 17, 2018, and September 27, 2018 : ACTION: UPON MOTION BY COMMISSIONER WITHERS, SECONDED BY COMMISSIONER SOLL, CARRIED 4-0-3 (COMMISSIONERS ROLPH, SMITH, AND CHAIR ROOT ABSENT), to approve the Minutes of the Regular Architectural Review Commission Meeting of August 27, 2018, as presented. ACTION: UPON MOTION BY COMMISSIONER SOLL, SECONDED BY COMMISSIONER BELLER CARRIED 4-0-3 (COMMISSIONERS ROLPH, SMITH, AND CHAIR ROOT ABSENT) to approve the Minutes, of the Regular Architectural Review Commission Meeting of September 17, 2018, as amended. Attachment 5 Packet Page 140 Minutes – Architectural Review Commission Meeting of October 15, 2018 Page 2 Item #2 action votes should be amended to 6-0-1 from 6-1-0 as Vice-Chair Nemcik was absent at the 9/17/18 meeting. ACTION: UPON MOTION BY COMMISSIONER SOLL, SECONDED BY COMMISSIONER BELLER, CARRIED 4-0-3, (COMMISSIONERS ROLPH, SMITH, AND CHAIR ROOT ABSENT) to approve the Minutes of the Special Architectural Review Commission Meeting of September 27, 2018, as presented. PUBLIC HEARINGS 2. 3895 Broad Street and 660 Tank Farm Road. Review of a mixed-use development project with approximately 45,000 square feet of retail space and assisted living facility with 111 assisted living suites and 28 memory care studio units; Case #: ARCH-1486-2018, C/OS- SP, BP-SP, and C-C-SF zones; NKT Development LLC and Westmont Development, applicants. Applicant Representatives, Principal Planner Carol Florence, Associate Planner Emily Ewer, Architects Aaron Clark, and Ken McKently provided a PowerPoint presentation and responded to Commissioner inquiries. Project Manager, Dave Watson presented the staff report with the use of a PowerPoint presentation and responded to Commissioner inquiries. Public Comments: James Lopes End of Public Comment-- ACTION: MOTION BY COMMISSIONER ROLPH, SECOND BY COMMISSIONER WITHERS, MOTION FAILED 1-4-2 (COMMISSIONERS BELLER, SOLL, WITHERS, AND VICE CHAIR NEMCIK VOTED NO, AND COMMISSIONER SMITH AND CHAIR ROOT ABSENT) to significantly redesign the project to be more pedestrian friendly, including clustered buildings and paseos, and bring material boards back to ARC to review. ACTION: MOTION BY COMMISSIONER BELLER, SECOND BY COMMISSIONER VICE CHAIR NEMCIK, CARRIED 5-0-2 (COMMISSIONER SMITH AND CHAIR ROOT ABSENT) to recommend to the Planning Commission that the project is consistent with Community Design Guidelines and Airport Area Specific Plan guidelines with significant recommended direction provided by the ARC as listed below: Community Connectivity and Site Design Submittal plans should include a sidewalk for pedestrians walking between Westmont and the shopping center, include internal sidewalks/paths of travel from street frontages to the grocery, and distinguish pedestrian walkway materials from Attachment 5 Packet Page 141 Minutes – Architectural Review Commission Meeting of October 15, 2018 Page 3 surroundings to encourage community connectivity and development density as a single item. Provide internal paseo or plaza. Create an internal street across north access with a sidewalk and shaded trees, between Buildings 1 and 5, close to the entrance. Include/add sidewalk along woonerf street, and address conflict between truck loading and pedestrians, consider moving the designated truck loading area to the north, to avoid conflict with the senior housing. Show bicycle parking and electronic vehicle (EV) stations dispersed over sites. Increase setbacks along Tank Farm Road. Make sidewalk along Tank Farm Road more pedestrian friendly (curvilinear, vertical elevation). Create as much landscaping as possible surrounding building 4, as it’s a busy corner and elevating the sidewalk near Tank Farm is necessary. Suggest creating a walkway along the wetlands/creek edge, a sidewalk between the two projects, and more landscap ing between buildings 2 and 3. Provide more variety in street trees along frontage. Architectural Design There is inconsistency with truncated hips, consider making them full hips, to clean up the architectural language. Remove tack-on trellis on second floor, consider having true trellis/arbor on ground floor with ample ground floor growing areas and soil to support vegetation growth on trellis/arbor, to help with sun protection on south exposure. Consider something robust, a solid shading structure, and consider vertical fins. Create canopies and arcades in commercial space to create visual links. Add shading structures on elevations to provide passive solar benefit. Show neutral, restrained color pallets, no white stucco or mustard colors. Address billboard architecture by revisiting building elevations and signage; define true sign program based on available sign areas. Consider toning down the step backs to make it more human scale architecture; review setbacks of upper floors per Guidelines (over 14 feet, step back upper floor). Attachment 5 Packet Page 142 Minutes – Architectural Review Commission Meeting of October 15, 2018 Page 4 Address the “angled” building at the corner versus keeping with the straight street edges. Simplify and tone down the architecture, particularly the elements of the smaller buildings. Recess: Commission recessed at 7:02 p.m., returning at 7:06 p.m. with all commissioners present. 3. 3825 South Higuera Street. Review of a 30-unit live/work project consisting of façade improvements to the existing Tribune offices to remain adjacent to South Higuera Street, demolition and redevelopment of the eastern portion of the Tribune production building, including the construction of three new buildings totaling approximately 50,000 square feet including the northern shell along Hind Lane to remain), reconstruction and expansion of the existing parking lot to provide a total of 226 parking spaces (including 117 existing parking spaces to remain), removal of 36 trees and the planting of 67 new trees and associated landscaping, and consideration of consistency with the adopted Mitigated Negative Declaration of Environmental Review (EID-1820-2018); Case #: ARCH-0932-2017, M-SP zone; Taylor Judkins, applicant. Senior Planner Shawna Scott presented the staff report with the use of a PowerPoint presentation and responded to Commissioner inquiries. Joel Snyder, Ten Over Studio provided a presentation with the use of a PowerPoint presentation and responded to Commissioner inquiries. Public Comments: None End of Public Comment-- ACTION: MOTION BY COMMISSIONER SOLL, SECOND BY COMMISSIONER ROLPH, CARRIED 5-0-2 (COMMISSIONER SMITH, AND CHAIR ROOT ABSENT) to adopt Resolution No. ARC-1018-2018 entitled: A RESOLUTION OF THE ARCHITECTURAL REVIEW COMMISSION OF THE CITY OF SAN LUIS OBISPO, CALIFORNIA, APPROVING THE DESIGN OF A NEW LIVE/WORK PROJECT, REMOVAL OF 36 TREES, WITH A DETERMINATION THAT THE PROJECT IS CONSISTENT WITH THE ADOPTED MITIGATED NEGATIVE DECLARATION FOR THE OVERALL PROJECT, AS REPRESENTED IN THE STAFF REPORT AND ATTACHMENTS DATED OCTOBER 15, 2018 (3825 SOUTH HIGUERA, ARCH-0932-2017) with the following suggestions provided: Use a metal siding that better complements the masonry. Attachment 5 Packet Page 143 Minutes – Architectural Review Commission Meeting of October 15, 2018 Page 5 Recommend keeping the Tribune office building close to its current appearance, with a cleanup needed. Consider removal of wood panels on Tribune office building. Recommendation to the applicant to add public art on property. 4. 1251 Calle Joaquin. Architectural review of a sign program for the new BMW of San Luis Obispo auto dealership, including a request to allow a sign that will be approximately 34 feet above the adjacent grade where 25 feet above grade is normally allowed. This project is categorically exempt from environmental review; Case #: ARCH-1760-2018, C-T-SF zone; Richard A. Rice, applicant. Deputy Director Doug Davidson presented the staff report with the use of a PowerPoint presentation and responded to Commissioner inquiries. Rick Rice with R&R Signs responded to Commissioner inquiries. Public Comments: None End of Public Comment-- ACTION: MOTION BY COMMISSIONER BELLER, SECOND BY VICE CHAIR NEMCIK, CARRIED 5-0-2 (COMMISSIONER SMITH, AND CHAIR ROOT ABSENT) to adopt Resolution ARC-1019-2018 entitled: A RESOLUTION OF THE SAN LUIS OBISPO ARCHITECTURAL REVIEW COMMISSION APPROVING A SIGN PROGRAM FOR THE BMW OF SAN LUIS OBISPO AUTOMOBILE DEALERSHIP WITH A CATEGORICAL EXEMPTION FROM ENVIRONMENTAL REVIEW, AS REPRESENTED IN THE STAFF REPORT AND ATTACHMENTS DATED OCTOBER 15, 2018 ( 1251 CALLE JOAQUIN ARCH-1760- 2018), as presented. COMMENT AND DISCUSSION Staff Updates- a. 2019-21 Financial Plan Advisory Body Goal Setting Deputy Director Davidson explained the financial plan and the ARC’s role in the Goal setting process. ACTION: MOTION BY COMMISSIONER WITHERS, SECOND BY COMMISSIONER SOLL, CARRIED 5-0-2 (COMMISSIONER SMITH, AND CHAIR ROOT ABSENT) to update the Community Design Guidelines (CDG) as the one recommended goal of the ARC for the 2019-21 Financial Plan. Attachment 5 Packet Page 144 Minutes – Architectural Review Commission Meeting of October 15, 2018 Page 6 b. Selection of a subcommittee to review the resubmitted plans for the Hotel at the Creamery (1027 Nipomo) in conjunction with a subcommittee of the Cultural Heritage Committee Deputy Director Davidson explained the process of selecting a subcommittee to review the resubmitted plans for the Hotel at the Creamery. By consensus, the Commission recommended COMMISSIONER WITHERS as a subcommittee member, along with CHAIR ROOT. COMMISSIONER BELLER will be an alternate if CHAIR ROOT or COMMISSIONER WITHERS are unavailable. c. Agenda Forecast Deputy Director Davidson provided a brief agenda forecast. ADJOURNMENT The meeting was adjourned at 8:09 p.m. The next Regular meeting of the Architectural Review Commission is scheduled for Monday, November 5, 2018 at 5:00 p.m., in the Council Hearing Room, 990 Palm Street, San Luis Obispo, California. APPROVED BY THE ARCHITECTURAL REVIEW COMMISSION: 12/03/2018 Attachment 5 Packet Page 145 3427 Miguelito Court San Luis Obispo, CA 93401 805.541.4509 p 805.546.0525 f www.oasisassoc.com CP 0184 15 ● RL A 224 8 ● CLAR B 907 Post-ARC Project Updates Submitted to the City of San Luis Obispo NWC of BROAD STREET & TANK FARM ROAD SPEC-1482-2018 (+) 20 December 2018 REFERENCES 1.NWC Vesting Tentative Tract Map #3115/ Notes from ARC Review 10-15-2018, Watson Planning Consultants, 17 October 2018 2.Hearing Minutes for the Regular Meeting of the Architectural Review Commission, October 15, 2018 3.Revised and consolidated project plans; “NWC Broad Street at Tank Farm Road” 18 December 2018 Since the initial March 20, 2018 application and submittal, the Northwest Corner of Broad Street and Tank Farm Road Mixed Use Project has experienced various revisions and iterations in response to staff comments and various City decision-making and advisory direction. Below is a synopsis of the design revisions completed in response to the October 15 Architectural Review Commission’s (ARC) recommendation of approval for the project with specific design direction. Not outlined in this synopsis are all of the design changes completed prior to the ARC hearing, however some of the more relevant changes are noted. Since the project is still “in process”, the applicant has focused on updating the architectural site plans and details. The civil engineering plans have not been updated to reflect some of the newest configuration revisions and adjustments. The adjustments do not materially change the site’s grading, utilities, or other site engineering elements therefore, the Architectural Site Plans takes precedence if there are any differences between the architectural and civil site plan configurations. Design Modifications Westmont Living 1.Loading area and trash enclosure have been relocated to create a patio area adjacent to the Woonerf and a designated pedestrian crossing to the shopping center. 2.The back of house area, located on the first floor, has been reconfigured to better access the loading area. 3.Front parking area has been slightly reconfigured to create a patio area and two (2) additional parking spaces, such that the total parking provided now stands at 72 spaces. 4.Building colors and materials have been are updated. (See response to comment below.) Shopping Center 1.Additional and enhanced internal pedestrian pathways have been incorporated: east-west path between Buildings 1 and 5, and a north-south path between buildings 4 and 5. Trellis elements have been judiciously added to these enhanced pedestrian crossings. (See response to comments below.) Three (3) vehicle parking spaces were removed to accommodate the pedestrian enhancements, the total parking provided now stands at 214 spaces. Attachment 6 Packet Page 146 OASIS ASSOCIATES, INC. 20 December 2018 NWC B@TF; Post-ARC Updates– SPEC 1482-2018 Page 2 of 4 3427 Miguelito Court San Luis Obispo, CA 93401 805.541.4509 p 805.546.0525 f www.oasisassoc.com CP 0184 15 ● RL A 224 8 ● CLAR B 907 2. Tenant signage is now located on the canopy ledge vs. the building wall(s). 3. Building 6 has been reconfigured and shifted to provide additional plaza area along the west and south frontages. The north storefront glazing has been removed and replaced with trellis to maintain four-sided architecture, while providing an interior back of house area for tenants and better establishing public entry points. There is no change building square footage. 4. An additional pedestrian access to the project has been added along the Broad Street frontage. Circulation & Public Improvements 1. The internal drive aisle between the Westmont facility and shopping center is designed in a woonerf style; this design was reviewed by the ARC. Renderings of the woonerf design are included in the updated project plans. 2. A phasing plan has been provided to show the proposed scope of public improvements associated with the various components of the project. Several of the ARC directional items were specific to either the Shopping Center or Westmont Living component, however these references are not explicitly included in the meeting minutes. The applicable component is noted after the item to provide context to the comment. NWC = Shopping Center WL = Westmont Living NWC/WL = Sitewide or Circulation ARC Direction Item Applicant’s Response 1. View pedestrian and bicycle connections “holistically”, taking into consideration community connectivity. (NWC/WL) Additional pedestrian connections have been added to the site design, see response comments below for more details. 2.Show bike parking and EV stations dispersed over sites. (NWC/WL) Bike parking is distributed throughout the site, near building entrances. EV stations are also located at various location in the parking areas and identified on A-010 and A1.1. 3.Add pedestrian walk along western wetland/creek edge. (NWC/WL) See SP-1 for proposed decomposed granite pathway along creek edge. 4.Internal paseo or plaza. (NWC) Additional pedestrian connections have been added. (See SP-1) Trellises where appropriate and feasible have been added along the connection paths (See TR-01 for design detail.) 5.Include internal sidewalks-paths of travel from street frontages to Grocery. (NWC) 6.Distinguish pedestrian walkway materials from surroundings. (NWC/WL) 7.Include/add sidewalk along woonerf street – address conflict between truck loading and peds. (NWC/WL) A function of the woonerf design is to “share the road” and blur the hard delineations between various transportation modes. The delineated pedestrian crossings to the north and south of Building 1 provide access to the westerly sidewalk and the option of sidewalk travel for pedestrians. 8.Make sidewalk along Tank Farm Rd more pedestrian friendly (curvilinear, vertical elev). (NWC/WL) The 6 foot sidewalk along Tank Farm Road includes a 5 foot landscaped parkway, combined with the 15 (or more) feet of landscaped area on the project, the pedestrians will enjoy a “universal design” sidewalk with dappled sunlight thanks to street trees on both sides. The sidewalk is Attachment 6 Packet Page 147 OASIS ASSOCIATES, INC. 20 December 2018 NWC B@TF; Post-ARC Updates– SPEC 1482-2018 Page 3 of 4 3427 Miguelito Court San Luis Obispo, CA 93401 805.541.4509 p 805.546.0525 f www.oasisassoc.com CP 0184 15 ● RL A 224 8 ● CLAR B 907 also buffered from the road and consistent the City’s and Airport Area Specific Plan’s design standards. See Sidewalk Section on SP-1. 9.Increase setbacks along Tank Farm Rd. (NWC) Setbacks are consistent with the Airport Area Specific standards which are 15-feet greater than that required by the underlaying zoning. 10. Expand Tank Farm Rd landscaping to more closely mirror the Retail Center landscaping. (WL) Street front landscape areas are of similar size and design for the length of Tank Farm Road. See SP-1, L1 (Westmont) for landscape information, 11. More variety in street trees along frontage. (NWC/WL) Street tree variety will continue to be consistent with City street tree standards 12. Avoid truncated hip roofs. (WL) Roof hips have been updated to reflect four- sided full hip roofs (See Renderings 1 to 9) 13. Remove tack on trellis on 2nd floor – incorporate true trellis/arbor on ground floor with ample ground floor growing areas to support vine growth on trellis/arbor. (WL) Trellis have been removed from the design and have been replaced with metal awnings. See A5.1 for perspective rendering and See A6.3 for awning detail. 14. Consider use of canopies/arcades to tie buildings together. (NWC) The shopping center buildings are designed with entry awnings with a consistent design aesthetic. Trellised sections of walkways provide connection between the buildings. Outdoor patio spaces have remained open for flexibility of use and configuration by tenants. 15. Add shading structures on elevations – passive solar benefit. (WL) See response to comment 13. 16. Neutral – restrained color pallets – no white stucco or mustard colors. (WL) Building color palette has been updated to a restrained selection of terra, wood, and taupe browns. 17. Address “billboard” architecture by revisiting bldg. elevations and signage. (NWC) Building faces no longer have any “billboard” function as all tenant signage is proposed as ledge signs on the metal canopies. The building elevations and vertical articulation are maintained to provide visual interest, highlight building entry points, and design character. 18. Define true sign program based on available sign areas. (NWC/WL) The project’s ledge signs for tenants complies with the City-wide sign regulations. The other monument signs (one for Westmont Living and one for the Shopping Center were included in the ARC reviewed designs. 19. Review setbacks of upper floors per Guidelines (over 14’ – step back upper floor). (NWC) Our understanding is that this comment was made in reference to Building 1 (anchor/grocer) of the shopping center. The section of the guidelines is provided here for reference: Community Design Guideline 3.2.D.4 “Vertical wall articulation. The height of building walls facing streets or on-site Attachment 6 Packet Page 148 OASIS ASSOCIATES, INC. 20 December 2018 NWC B@TF; Post-ARC Updates– SPEC 1482-2018 Page 4 of 4 3427 Miguelito Court San Luis Obispo, CA 93401 805.541.4509 p 805.546.0525 f www.oasisassoc.com CP 0184 15 ● RL A 224 8 ● CLAR B 907 pedestrian areas should be varied so that the vertical mass is divided into distinct, human- scaled elements. See Figure 3-16. a. Except on a pedestrian-oriented public street where buildings are at the back of the sidewalk, structures over 20 feet in height (typical for structures of two stories or more) should step-back the building mass at least five feet for the portions of the structure above 14 feet (or the height where an actual second story begins) to provide visual variation.” Building 1 is a single-story structure with a roof height of ±19 feet in height. This building does not have a second story to accommodate a setback. The parapet and roof heights range from 22 to 34 feet. This style and design are consistent, appropriate, and typical for a well-designed and articulated retail anchor building. 20. The “angled” building at the corner v. keeping with the straight street edges. (NWC) Community Design Guideline 3.1.C.2.b: “Buildings may be angled to create interesting juxtapositions if there is a clear and desirable design goal to be achieved.” The angle of the corner building responds to a number of site design factors. The building responds to an existing easement on the corner while providing the greatest extent of street presence possible as an anchor of the corner. The soft angle of the building orientation does not appear catawampus in street view, yet the angle helps activate the street corner by providing direct pedestrian access into the center with street view of patio areas and connections to other buildings. 21. Toning down and simplifying the architecture, particularly the smaller buildings. (NWC) Building architecture has been maintained to provide vertical and horizontal articulation and human-scale detailing. The center’s overall design aesthetic provides a sense of consistency but with individual designs for each building. End of Applicant’s Response Attachment 6 Packet Page 149 Attachment 7Packet Page 150 Attachment 7Packet Page 151 Attachment 7Packet Page 152 Attachment 7Packet Page 153 Attachment 7Packet Page 154