Casa-Stenner-Murray Waterline Replacement Specification 91312 - Plans
Project Locations1.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR PERMITTEE TOCONTACT "UNDERGROUND SERVICE ALERT U.S.A." TOLL FREE AT 1-800-227-2600FORTY-EIGHT (48) HOURS PRIOR TO START OF CONSTRUCTION, FOR LOCATION OFPOWER, TELEPHONE, OIL AND NATURAL GAS UNDERGROUND FACILITIES.CONTRACTOR OR PERMITEE SHALL ALSO CONTACT THE APPROPRIATE AGENCYFOR THE LOCATION OF CABLE T.V., WATER, SEWER, DRAINAGE ORUNDERGROUND FACILITIES.2.THE CONTRACTOR SHALL POSSESS A CLASS "A" OR "C-34" LICENSE AT THE TIMEOF BID OPENING.3.CONTRACTOR SHALL VERIFY DEPTH AND LOCATION OF ALL CROSSINGS PRIOR TOLAYING PIPE SO THAT PIPE ALIGNMENT AND GRADE CAN BE ADJUSTED ASNEEDED.4.CONTRACTOR SHALL VERIFY DEPTH, LOCATION, SIZE AND MATERIAL OF PIPE ATALL TIE-INS. WATERLINE ALIGNMENT AND GRADE SHALL BE ADJUSTED AS NEEDEDBASED ON THE FINDINGS. CONTRACTOR SHALL PROVIDE ALL THE NECESSARYPIPE, FITTINGS ADAPTERS, THRUST BLOCKS AS NEEDED TO ACCOMPLISH THETIE-IN.5.CONTRACTOR SHALL PROVIDE TEMPORARY BLOW-OFFS, CONNECTIONS, VALVES,ETC. AS NEEDED TO FACILITATE TESTING, DISINFECTING AND FLUSHING OF NEWPIPELINE.6.SEWER LATERALS EXIST WHICH ARE NOT SHOWN ON THESE PLANS.CONTRACTOR TO PROCEED WITH CAUTION WHEN TRENCHING AND SHALL HAVEALL NECESSARY MATERIALS ON HAND TO REPAIR LATERALS IF DAMAGED.CONTRACTOR SHALL VERIFY DEPTH OF LATERALS TO AVOID CROSSINGCONFLICTS.7.CONTRACTOR SHALL ASSUME ALL EXISTING WATER VALVES ARE UNRESTRAINED.8.TIE OUT CENTERLINE MONUMENTS BEFORE WORK AND REPLACE IF DISTURBED INACCORDANCE WITH THE LAND SURVEYORS ACT, AND SECTION 5-1.36E, REPLACEMONUMENT AND WELL PER ENG. STD. 9040.9.THE CONTRACTOR SHALL REPLACE ALL PAVEMENT STRIPES, MARKINGS, ANDMARKERS DISTURBED DURING CONSTRUCTION. ALL STRIPING IS PER STATESTANDARD PLANS AND PER PER ENGINEERING STANDARD SPECIFICATION84-1.01A.10.THERE SHALL BE NO FITTINGS ON ANY OF THE SERVICE LINES REGARDLESS OFPIPE MATERIAL BETWEEN THE MAIN AND THE WATER METERS UNLESS SHOWN ONENG. STD. 6210.11.THE CONTRACTOR MUST PROVIDE SHORING AS NECESSARY TO PREVENTMOVEMENT OF THE EXISTING WATERLINE. ANY MATERIAL THAT FALLS INTO THETRENCH FROM THE SURROUNDING AREA SHALL BE REPLACED AT THECONTRACTOR'S EXPENSE.12.SHORING IS REQUIRED WHEN NEW WATER MAIN IS INSTALLED WITHIN 5 FEET OF(E) TRANSITE WATER MAIN.13.ALL 3/4" SERVICES MUST BE UPSIZED TO 1" IPS TUBING AND BOX. ALL 1 1/4" & 1 1/2"SERVICES MUST BE UPSIZED TO 2" CTS TUBING AND BOX. ALL OTHER SERVICELINE SIZES AND BOXES TO BE REPLACED IN KIND PER CURRENT ENGINEERINGSTANDARDS.14.CONTRACTOR MUST REPLACE ALL METERS WITH NEW METERS FURNISHED BYTHE CITY.15.PIPE INSTALLED WITH LESS THAN 3 FEET OF COVER SHALL COMPLY WITH ENG.STD. 6020 SLURRY BACKFILL PIPE INSTALLED WITH 3 FEET OR MORE OF COVERSHALL COMPLY WITH ENG. STD. 6020.16.PIPE INSTALLATION AND CROSSINGS MUST BE PER ENG. STD. 6110 AND 6140.CENTER NEW PIPE OVER CROSSING.17.ALL MECHANICAL FITTINGS MUST HAVE RESTRAINTS21Connect (E) water service to new mainper Eng. Std. #6220, Type 1.Install (N) Fire Hydrant assembly per Eng.Std. #6310. Fire service separation per detail12, sheet 13Replace (E) water service and connect to newmain per Eng. Std. #6210. Replace customervalve, city valve and all fittings per Eng. Std.#6210. 13. See General Note 13.Replace (E) water services andall fittings per Eng. Std. #6260.Remove and replace curb andgutter to make connections.3(E) Survey Monument - Replace if damaged or destroyed. See General Note 8.Install Thrust Block - size as neededInstall Cap or PlugInstall Water Valve (same size as line) per Eng. Std. #6340Abandon per Eng. Std. 6050PCCACPortland Concrete CementAsphalt Concrete(E) or (e)Existing (N) or (n)NewMJMechanical JointFLGFlange4Abandon service per Eng. Std. #6050NSheet NumberDetail Number##Extend fire lateral to main perEng. Std. 6530 & 6590.65Connect (e) fire lateral to (n)main per Eng. Std. 6530. Fireservice separation per detail10, sheet 9Reference Documents:City Standard Specifications - May 2018 EditionCity Engineering Standards - May 2018 Editionindex to planssheet no.descriptionsan luis obispo county, californiaAPPROVED BYSPECIFICATION NO.DATESHEETMatthew A. Horn, City Engineer R.C.E. C63611 Approved Date91312FILE NO./LOCATION123456789COVER SHEETMURRAY AVE. STA. 0+70 TO 6+30MURRAY AVE. STA. 6+30 TO 12+00MURRAY AVE. STA. 12+00 TO 17+50CASA STREET STA. 20+00 TO 25+50CASA STREET STA. 25+50 TO 29+00STENNER STREET STA. 30+00 TO 35+70CHORRO MEINECKE AND MURRAYCONNECTION DETAILSFHT.O.P.FIRE HYDRANTTOP OF PIPEC.I.CAST IRONDIPDUCTILE IRON PIPEPVCPOLYVINYL CHLORIDE B.O.P.BOTTOM OF PIPEPEPLAIN END(E) Survey Monument - Protect in place(E) Meter boxReplace meter box and lid per Eng. Std. #6210PPPOWER POLEBOBLOW-OFF9of1XXXX XX, 2019WATERLINE ABANDONMENT& CONNECTIONS 2016FEBRUARY 20197Install (n) Fire Service per Eng.Std. 6530. Double check backflowpreventer per Eng. Std. 6420Install (n) 6" Water Serviceand vault per Eng. Std. 62508 KEEP CLEAR MURRAY AVE.SANTA ROSA (HWY 1)SEWER LATGAS GAS (E) 10" SEWER(E) 2" GAS(E) 8" CI (E) 4" GAS(E) 10" C.I. WATER1047 1041 1037 1035 1027 1021 1010 1049102104889 3/4" COPPER 3/4" COPPER 3/4" COPPER 1 1/2" COPPER 6" WATER SERVICE ABANDONED NO METER 1" POLYETHYLENE 2" COPPER 3/4" COPPER NABANDON (E) 6" CI WATER(E) 4" GAS(N) 12" PVC WATER(E) 6" SEWER(E) 6" S E W E R (E) 4" CABLE TV(E) TV(E) FIBER OPTICS (E) ATT CONDUITREPLACE TRAFFIC LOOPSPER STATE STANDARD E5-5BREMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)REMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)20550100DIDI12'x12' RC CULVERT(E) 4'x4' R C C U L V E R T (E) 18" PVC STORM DRAIN12'x12' RC CULVERTLPTSTSLPTS(E) ELECTRICALTS(E) ELECTRICAL(E) 4" GAS(N) 12" PVC WATER(E) 8" PVC SEWER(E) ATT CONDUITREMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)(N) 2" SERVICE(E) 1" COPPER3 2223224ABANDONED NO METER 48+100+200+300+400+500+600WATER19REMOVE (E) 6" CI WATER WITHIN STATE R/WSEWER LAT STATE R/WSTATE R/WSTATE R/WWATERVAULTDI34' 15'5' 5'ABANDON (E) 6" CI WATERABANDON (E) WATERLINEPER ENG. STD. 6050(N) 12" GATE VALVE(N) 12" GATE VALVEABANDON (E) WATERLINEPER ENG. STD. 6050(E) 4" GAS111.25° MJXMJFITTINGS5'3' 6" FIRE SERVICE 7REMOVE (E) 6"CMP & INLET(N) 6'x2' CATCH BASIN PER CALTANS STD. D72D (TYPE GT3). FRAMEAND GRATE PER CALTRANS STANDARD PLAN D77A (TYPE 24-12)TC = 236.5'INV OUT = 232.5'REMOVE AND REPLACE EXISTING SIDEWALK (400 SF), CURB ANDGUTTER (70 LF) TO THE NEAREST SCORE MARK PER CITY STD. 4110(N) 20 LF 12" PVC (SDR 35)DRAIN TO DAYLIGHT45° MJXMJFITTINGS45° MJXMJFITTINGSPROTECT (E) PARAPETAND RAILINGREMOVE (E) 12"CMP & INLETREMOVE (E) FIRE SERVICE VAULT1+001+502+002+503+003+504+004+505+005+506+002MURRAY STREETCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHHORIZ 1" = 20'VERT 1" = 2'(N) 45° MJXMJFITTINGS(E) 4x4 CULVERT10" T.O.P.(E) DOUBLE 12'x12'CONCRETE CULVERT(E) 4" PVCCABLE2.4' T.O.P.EXISTING GRADEOVER NEW PIPE228244242240238236234232230227229243241239237235233231MATCHLINE - STA. 6+30.00: SEE SHEET 3 228244242240238236234232230227229243241239237235233231MATCHLINE - STA. 6+30.00: SEE SHEET 312" DIP TO PVCTRANSITION COUPLING12" DIP TO PVCTRANSITION COUPLING(N) 70 LF 12" C900 PVC WATER(CLASS 305 DR-14)FULLY RESTRAINED PIPEDOUBLE POLYETHYLENE WRAP ALL JOINTS AND FITTINGSSTATION 0+70 TO 5+50140 LF - 12" DIP (CLASS 350)(2) 45° MJXMJ FITTINGS(2) 45° MJXMJ FITTINGS(N) FH LATERAL(N) FH LATERAL2'(2) 45° MJXMJFITTINGS1.0' 3' MIN.CONNECT TO(E) 10" CI WATER(N) FH LATERAL(N) 480 LF 12" C900 PVC WATER(CLASS 305 DR-14)2" SANDBEDDING(N) 45° MJXMJFITTINGS(N) 12" PVC (SDR 35)9" ± STOPSTOP STOP(E) 6" CI WATER(E) 2" GAS(ABND.) 10" SEWER(E) 8" SEWER204 11121064 (E) 6" VCP SEWER (ABND) 8" SEWER(ABND) 10" SEWER(E) 8" SEWER(E) 2" GAS PPMURRAY AVE .CASA ST.GAS GASGASGAS GAS 1175 1165 1155 1145 1067106110511053 1118 1124-6 1152 1158 1164 1172 3/4" COPPER 3/4" COPPER 2" COPPER 3/4" COPPER 3/4" COPPER 3/4" COPPER 3/4" COPPER3/4" COPPER3/4" COPPER 3/4" COPPER 1 1/2" COPPER 1 1/2" COPPER 3/4" COPPER 2" COPPER 1209 2" COPPER (E) 4" SEWER LATERALN (N) 12" PVC WATER (E) 2" GAS (N) 8" PVC WATERLINE (E) 4" AC WATER (E) 2" AC WATER (E) 6" CI ABANDON (E) 6" CI WATER45° MJXMJFITTINGSABANDON (E) WATERLINEPER ENG. STD. 6050REMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)2939REMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)20550100(E) 12" PVC SD +00 +30 00 +3112222222+700+800+900+1000+1100+12+00 +20 00 +21 SEWER LAT 34' 10'5'10'ABANDON (E) 6" CI WATER(E) 4" GAS(N) 12" PVC WATER(E) 8" VCP SEWER(E) ATT CONDUIT(E) 18" PVC STORM DRAIN34'15'5'5'ABANDON (E) 6" CI WATER(E) 4" GAS(N) 8" PVC WATER(E) 6" VCP SEWER(E) ATT CONDUITABANDON (E) 6" CI WATER(E) 4" GAS(N) 8" PVC WATER(E) ATT CONDUIT(E) 6" VCP SEWER22232223/4" COPPER ABANDON (E) 6" WATERLINEPER ENG. STD. 6050RESTORE CROSS GUTTERPER ENG. STD. 4310STENNER ST. ABANDON (E) 6" CI WATER(N) 12" PVC WATERABANDON (E) 6" CI WATER(E) 12" PVC SD(E) 8" VCP SEWER(E) 4" GAS1ABANDON (E) 6" WATERLINEPER ENG. STD. 60506+507+007+508+008+509+009+5010+0010+5011+0011+5012+002282292302312322332342352362372382392402412422432442452462472282292302312322332342352362372382392402412422432442452462473MURRAY STREETCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHHORIZ 1" = 20'VERT 1" = 2'(E) 8" SEWER INVERT 9.7' T.O.P.(E) 2" GAS3.2' T.O.P.(E) GRADE OVERNEW PIPE(E) ABANDONED SEWER6.9' T.O.P.MATCHLINE - STA. 6+30.00: SEE SHEET 2 MATCHLINE - STA. 12+00.00: SEE SHEET 4 SEE SHEET 7SEE SHEET 5MATCHLINE - STA. 6+30.00: SEE SHEET 2 MATCHLINE - STA. 12+00.00: SEE SHEET 4(E) 18" PVCSTORM DRAIN1.0'MIN.INSTALL FITTINGSAS NEEDED(N) 480 LF 12" C900 PVC WATER(CLASS 305 DR-14)(N 1,000 LF 8" C900 PVC WATER(CLASS 305 DR-14)(E) 6" CI WATER(N) 8" PVC WATER(E) 6" SEWER7.7' T.O.P.(E) 2" GAS(E) 12" PVCSTORM DRAIN3' MIN.(N) 12"X8" REDUCER(N) FH LATERAL(N) FH LATERAL(E) 6" CI WATERFULLY RESTRAINED PIPEDOUBLE POLYETHYLENE WRAP ALL JOINTS AND FITTINGSSTATION 6+60 TO 7+90FULLY RESTRAINED PIPESTATION 11+30 TO 12+40 (E)10" PVC SEWER R ABND. 6" VCP SEWER (E) 6" GAS GAS (E) TELECOMMUNICATIONS 8" GAS PPTELESTENNER ST.MURRAY AVE.1206121212241230 1262 1279 1277 1273 1271 1269 1267 12651247121312093/4" COPPER3/4" COPPER3/4" POLYETHYLENE3/4" COPPER 3/4" COPPER 3/4" COPPER 2" COPPER 1" COPPER 3/4" COPPER 3/4" COPPER 3/4" COPPER 2" COPPER 2" COPPER 2" COPPER3/4" COPPER2" COPPER 4" FIRE SIERVICE (E) 10" PVC WATER (E) 8" GAS ABANDONED 10" CI WATER (E) TELECOMMUNICATIONS (E) GAS(E) 10" PVC SEWER coMURRAY AVE.3" SERVICE49ABANDON (E) WATERLINEPER ENG. STD. 6050REMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACE PERCITY ENG. STD. 6310 (6" DIA.)ABANDON (E) WATERLINEPER ENG. STD. 6050REMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)59DI 48" x 3 3 " C U L V E R T (N) 8" PVC WATER4" FIRE SERVICE 62335112222232122322INSTALL IN PLACE 8" PVC WATERREMOVE (E) 6" CI WATERABANDON (E) 8" PVC WATER(E) 6" VCP SEWER+1747+00+1300+1400+1500+1600+17002" COPPER 34'11'5'10' 34' 11'5'10'(E) 4" GAS(E) 6" SEWER(E) GASINSTALL IN PLACE 8" PVC WATERREMOVE (E) 6" CI WATERABANDON (E) 8" PVC WATER(E) 6" VCP SEWER(E) 10" PVC WATER ABANDONED 10" CI WATER HATHWAY (E) ATT CONDUIT(E) ATT CONDUIT(E) ATT CONDUIT ABANDON (E) 6" CI WATER(E) ATT CONDUIT23823924024124224324424524624724824925025125225325425525625723823924024124224324424524624724824925025125225325425525625712+0012+5013+0013+5014+0014+5015+0015+5016+0016+5017+0017+504MURRAY STREETCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHHORIZ 1" = 20'VERT 1" = 2'EXISTING GRADEOVER NEW PIPEMATCHLINE - STA. 12+00.00: SEE SHEET 3 MATCHLINE - STA. 12+00.00: SEE SHEET 3 INSTALL FITTINGSAS NEEDED(N)1,000 LF 8" C900 PVC WATER(CLASS 305 DR-14)(N) FH LATERAL(N) FH LATERAL3' MIN.(E) 8" GAS(E) 6" VCP SEWERCONNECT TO (E) 10" PVC WATERFULLY RESTRAINED PIPESTATION 13+20 TO 14+10FULLY RESTRAINED PIPESTATION 17+00 TO 17+50FULLY RESTRAINED PIPESTATION 11+30 TO 12+40 STOPSTOP PacificBellgasgasNCASA ST.123 127 157 159 163165190-196184170 A-C 156 1112148 140 128 1064139 3/4"COPPER 1" COPPER pppppp(ABND) 8" SEWER(ABND) 10" SEWER(E) 8" SEWER(E) 2" GASpg&eppgas gasGAS 125 gas gas gas gas gasgas gas gas gas 3/4" POLYETHYLENE 3/4" COPPER 3/4" COPPER 3/4" COPPER (E) 1" COPPER3/4" COPPER 3/4" COPPER 3/4" COPPER 3/4" COPPER 3/4" COPPER 1" COPPER 153 3/4" COPPER 3/4" COPPER 1 1/2" COPPER(N) 12" PVC WATERABANDON (E) 6" CI WATERsewer lat comm29REMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)20550100(E) 12" PVC SD7+8 00 +2000+2100+2200+2300+2400+2500ABANDON (E) 6" CI WATER(E) 4" GAS(N) 8" PVC WATER(E) 6" VCP SEWER(E) ATT CONDUIT(N) 12" PVC WATERABANDON (E) 6" CI WATER(E) 12" PVC SD(E) 8" VCP SEWER(E) 4" GAS2232222(ABND) 8" SEWER(ABND) 10" SEWER(E) 15" SEWER(E) 2" GAS(N) 12" PVC WATERABANDON (E) 6" CI WATER(E) ATT CONDUIT1221222225' 3/4" COPPER 25' 5' 5' (N) 2" SERVICE 20+0020+5021+0021+5022+0022+5023+0023+5024+0024+5025+0025+502332342352362372382392402412422432442452462472482492502512522532332342352362372382392402412422432442452462472482492502512522535CASA STREETCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHHORIZ 1" = 20'VERT 1" = 2'DATE:MATCHLINE - STA. 25+50.00: SEE SHEET 6 SEE SHEET 3MATCHLINE - STA. 25+50.00: SEE SHEET 612" PVCSTORM DRAINATT CONDUITSCONNECT TO (N) WATEREXISTING GRADEOVER NEW PIPE(N)890 LF 12" C900 PVC WATER(CLASS 305 DR-14)(E) 6" CI WATER TOBE ABANDONED3' MIN.FULLY RESTRAINED PIPEDOUBLE POLYETHYLENE WRAPALL JOINTS AND FITTINGSSTATION 20+00 O 20+60 Pac BellvaultPacificBellpg&eelecpanel(E) 15" SEWER(E) 8" SEWER (E) 2" GAS CASA ST.77104 A B 1 4 5 8 32 60100 (E) 10" PVC WATER(E) 6" CI WATER2" COPPERpp ppppppgas gasgasgasgasgasgas gas 3/4" COPPER1 1/2" COPPER 2" COPPER 2" COPPER 2" COPPER ABANDONEDNO METER N(E) 15" SEWER(ABND.) 8" SEWER(ABND.) 8" SEWER(N) 12" WATERLINE(E) 2" GAS(ABND.) 8" SEWER(ABND.) 10" SEWERABANDON (E) 6" CI WATER(E) 6" FIRE (E) 6" FIRE (E) ATT CONDUITREMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)6920550100(E) 4'x4' SD BOX+2500+2600+2700+2800+2900(ABND) 8" SEWER(ABND) 10" SEWER(E) 15" SEWER(E) 2" GAS(N) 12" PVC WATERABANDON (E) 6" CI WATER(E) ATT CONDUIT4226333552DESERET7(E) 8" FIRE 55'6' (E) 4" FIRE 545° MJXMJFITTINGS5'5'ABANDON(E) MH(E) 6" FIRE (E) 6" FIRE 24324424524624724824925025125225325425525625725825924324424524624724824925025125225325425525625725825925+5026+0026+5027+0027+5028+0028+5029+0029+506CASA STREETCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHHORIZ 1" = 20'VERT 1" = 2'(E) 2" GASMATCHLINE - STA. 25+50.00SEE SHEET 5 MATCHLINE - STA. 25+50.00SEE SHEET 5 MATCHLINE - STA. 25+50.00: SEE SHEET 5 3' MIN.(N) FH LATERALEXISTING GRADEOVER NEW PIPE(N) 890 LF 12" C900 PVC WATER(CLASS 305 DR-14)CONNECT TO (E)10" CI WATER(E) 10" CI WATERFULLY RESTRAINED PIPESTATION 25+70 TO 26+501.0' STOP(E) 6" VCP SEWERSTENNER ST.gasgaspg&ecogasattpg&e1 1/2" COPPER185 183 163 159 155 133 123 115 103 128 124 132 136 144 146 176 1781901206 116411723/4" COPPER 3/4" COPPER 3/4" COPPER 3/4" COPPER2" COPPER3/4" COPPER2" COPPER 1" COPPER 1 1/2" COPPER 3/4" COPPER 3/4" COPPER 1" POLYBUTYLENE 3/4" COPPER 2" COPPER 3/4" COPPER 2" COPPER 135 137 139 153 151 149 147 145 143 1" POLY ETHYLENE MURRAY AVE.N(E) 2" GAS(N) 8" PVC WATERLINE(E) 6" PVC WATER (E) 6" CIcosmh2" COPPER 2" COPPER 1 1/2" FIRE 3/4" POLYETHYLENE REMOVE (E) FIRE HYDRANT PERENG. STD. 6050 AND REPLACEPER CITY ENG. STD. 6310 (6" DIA.)792055010039(N) 8" PVC WATER+3000+3100+3200+3300+3400+3500+11 00+12 00 ABANDON (E) 6" CI WATER(E) 4" GAS(N) 8" PVC WATER(E) ATT CONDUIT(E) 6" VCP SEWERABANDON (E) 6" CI WATER10'15'15' 10'15'15'ABANDON (E) 6" CI WATER(E) ATT CONDUIT(E) 6" VCP SEWER(E) 2" GAS(N) 8" PVC WATERLINEABANDON (E) 6" CI WATER3222122233323212SEWER LAT 152(E) 2" GAS ABANDON (E) WATERLINEPER ENG. STD. 6050222(N) 45° MJXMJFITTINGS(E) 8" PVCWATER30+0030+5031+0031+5032+0032+5033+0033+5034+0034+5035+0035+502402412422432442452462472482492502512522532542552562572582592402412422432442452462472482492502512522532542552562572582597STENNER STREETCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHHORIZ 1" = 20'VERT 1" = 2'SEE SHEET 3CONNECT TO (N)8" PVC WATERCONNECT TO (E)8" PVC WATER3' MIN. 3' MIN.EXISTING GRADEOVER NEW PIPE(N)570 LF 8" C900 PVC WATER(CLASS 305 DR-14)FULLY RESTRAINED PIPESTATION 35+00 TO ENDFULLY RESTRAINED PIPESTATION 30+00 O 30+60 (E) 3" GAS(E) 3" GAS (E) 4" GAS(E) 14" WATER CI (E) 14" CI WATER(E) 8" PVC (2004)CHORRO ST.807111790806MURRAY AVE.ABANDON (E) AIR VACPER ENG. STD. 605089(ABND.) 4" STEEL WATER(E) 4" GAS(E) 8" CI WATER (1970)(ABND.) 4" STEEL WATER+3950+4000+4050MEINECKE AVE.CHORRO ST.commgas505145804794(E) 2" GAS(E) 6" WATER(E) 3" GAS (E) 14" WATER (E) 3" GAS (E) 14" WATER 99+00+4950+5000+5050(E) 2" GAS(E) 6" WATER(E) GRADEOVER PIPE(E) 8" PVC WATER(E) 8" CI WATER(2) 45° MJxMJFITTINGS(2) 45° MJxMJFITTINGS(E) 14" CI WATERREMOVE (E) CROSSAND CONNECT PERDETAIL 8, SHEET 91.0'MIN.(N) 8" C900 PVC WATER(CLASS 305 DR-14)(E) GRADEOVER PIPE1.0' MIN.(E) 14" CI WATERREMOVE (E) CROSSAND CONNECT PERDETAIL 9, SHEET 9(2) 45° MJxMJFITTINGS(2) 45° MJxMJFITTINGS(N) 6" C900 PVC WATER(CLASS 305 DR-14)(E) 6" CI WATER(E) 6" CI WATER39+5040+0040+5023823924024124224324424524624724824925025125225325425523823924024124224324424524624724824925025125225325425525025125225325425525625725825926026126226326426526626725025125225325425525625725825926026126226326426526626749+5050+0050+50N205501008CHORRO, MEINECKE AND MURRAYCITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHHORIZ 1" = 20'VERT 1" = 2'N20550100 9CITY SPECIFICATION NO.DATE:PROJECT TITLE: SHEET TITLE:ofSHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONWATERLINE ABANDONMENT & CONNECTIONS 2016 MG/HNMB/MHMHFEBRUARY 2019913129KHCONNECTION DETAILSNTS REFERENCE SHEET 2MURRAY & SANTA ROSA1NTS REFERENCE SHEET 41224 MURRAY4NTS REFERENCE SHEET 3MURRAY & CASA2NTS REFERENCE SHEET 3MURRAY & STENNER3NTSLEGENDFLANGEFLANGED COUPLING ADAPTERRESTRAINED MECHANICAL JOINTTRANSITION COUPLINGNTS REFERENCE SHEET 4MURRAY & HATHWAYNTS REFERENCE SHEET 8CHORRO & MURRAY8NTS REFERENCE SHEET 6CASA & DESERET6NTS REFERENCE SHEET 7END OF STENNER7NTS REFERENCE SHEET 8CHORRO & MEINECKE59(N) 12" PVC WATER(E) 10" CI WATERREMOVE (E) 6" CI WATER(E) 10" CI WATER(E) 8" CI WATER(N) 10' PVC WATER(N) 10" GATE VALVEFLGxMJ(N) 12" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxMJ(N) 10"x10"x10" TEEFLGxFLGxFLG(N) 10"x10"x8" TEEMJxMJxFLGWITHIN STATE R/WCONTRACTOR TOVERIFY LENGTH(N) 8" PVC WATER(N) 8" PVC WATER(E) 6" CI WATER (N) 12" PVC WATER(N) 12" PVC WATERABANDON (E) 6" C.I. WATERABANDON (E) 6" C.I. WATERABANDON (E) 6" C.I. WATERABANDON (E) 6" C.I. WATER(N) 12"x12"x12" TEEFLGxFLGxFLG(N) 8"x8"x6" TEEMJxMJxMJ(N) 12" GATE VALVESFLGxMJ(N) 8" GATE VALVEFLGxMJ(N) 8" PVC WATER (N) 8" PVC WATER(N) 8" PVC WATER(N) 8" PVC WATER(E) 6" CI WATER ABANDON (E) 6" CI WATERABANDON (E) 6" C.I. WATER ABANDON (E) 6" CI WATERABANDON (E) 6" CI WATER(N) 8"x8"x6" TEEMJxMJxFLG(N) 8"x8"x6" TEEFLGxFLGxFLGABANDON (E) 6" CI WATER(N) 8" PVC WATER(N) 8" PVC WATER( N ) 8 " P V C W A T E R ABANDON (E) 8" PVC WATER(N) 45° MJxMJ(N) 6" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxMJ(N) 45° MJxMJ(N) 8" PVC WATER(N) 8" PVC WATER(N) 45° MJxMJABANDON (E) 8" PVC WATER(E) 10" PVC WATER (E) 10" PVC WATER(N) 45° FLGxMJ(N) 10"x10"x8" TEEFLGxFLGxFLG(N) 10" GATE VALVEFLGxMJ(N) 10" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxFLGABANDONED 6" CI WATER(N) 8" PVC WATER(N) 8" PVC WATER(N) 45° MJxMJ(N) 45° MJxFLG(N) 8"x8"x6" TEEFLGxFLGxFLG(N) 6" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxFLG(E) 6" CI WATER (E) 6" CI WATER (E) 8" PVC WATER(N) 8" GATE VALVEFLGxMJ(E) 8" PVC WATER(N) 12" PVC WATER(E) 8" DI FIRE ABANDON (E) 8" C.I. WATER (N) 12" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxMJ(N) 8" GATE VALVEFLGxMJ(N)12"x8" REDUCER(N) 12"x12"x8" TEEFLGxFLGxFLGNTS REFERENCE SHEETS 1 THRU 7FIRE SERVICE SEPARATION10(E) 14" CI WATER (N) 14" TRANSITIONCOUPLING(N) 14" TRANSITIONCOUPLING(N) 6" GATE VALVEMJxFLG(N) 45° FLGxMJ(N) 45°MJxMJ(E) 6" CI WATER(E) 6" CI WATERWATER(N) 6" PVC(N) 14" PVC WATER(N) 45°MJxMJ(N) 45°MJxMJ(E) 14" CI WATER (E) 14" CI WATER (N) 14" TRANSITIONCOUPLING(N) 14" BUTTERFLYVALVE MJxMJ(N) 8" GATE VALVEFLGxMJ(N) 45° MJxFLG(N) 45°MJxMJ(E) 8" CI WATER(E) 8" PVC WATERWATER(N) 8" PVC(N) 14" PVC WATER (N) 45°MJxMJ(N) 45°MJxMJ(E) 14" CI WATER(E) FIRE SERVICE(N) WATER(N) 45° MJxMJ(N) 45° MJxMJPROVIDE JOINT RESTRAINT WITHIN 20' OF NEW 45° FITTINGS(N) FIRE SERVICE2" MIN.(N) WATER(N) 45°MJxMJ(N) 45°MJxMJNOTE:1.EXISTING FIRE SERVICES MUST BE MAINTAINED DURING CONSTRUCTION.2.MAY WEST FITTINGS MAY BE USED TO ACHIEVE THE REQUIRED CLEARANCE.ABANDONED 4" STEEL WATERABANDONED 4" STEEL WATER5' MIN.5' MIN.5' MIN.5' MIN.(N)12"x10"REDUCER(N)12"x8" REDUCER