Loading...
HomeMy WebLinkAboutItem 7 - TTHM Pipe Gallery PlansP.O. BOX 1604 ARROYO GRANDE, CA 93421 (805) 904-6530 VICINITY MAP EDNA TANK PROJECT LOCATION NOT TO SCALE FOR PRELIMINARY USE ONLY NOT TO BE USED FOR CONSTRUCTION DATE:SEPTEMBER 2019 1 33 APPROVED BY SPECIFICATION NO. FILE NO./LOCATION DATE OF SHEET Reference Documents: City Standard Specifications - May 2018 Edition City Engineering Standards - May 2018 Edition 1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR PERMITTEE TO CONTACT "UNDERGROUND SERVICE ALERT OF NORTHERN CALIFORNIA" BY PHONE AT 8-1-1 FORTY-EIGHT (48) HOURS PRIOR TO START OF CONSTRUCTION FOR LOCATION OF POWER, TELEPHONE, OIL AND NATURAL GAS UNDERGROUND FACILITIES. CONTRACTOR OR PERMITEE SHALL ALSO CONTACT THE APPROPRIATE AGENCY FOR THE LOCATION OF CABLE T.V., WATER, SEWER, DRAINAGE OR UNDERGROUND FACILITIES. 2. THE CONTRACTOR SHALL POSSESS A CLASS "A" LICENSE AT THE TIME OF THE BID OPENING. 3. THE CITY HAS PERFORMED GEOTECHNICAL INVESTIGATIONS IN THE VICINITY OF THIS PROJECT. "GEOLOGIC/GEOTECHNICAL STUDY SAN LUIS OBISPO WATER TREATMENT PLANT IMPROVEMENT PROJECT, GEOMATRIX, 2006" IS AVAILABLE FOR CONTRACTORS REVIEW IN THE PROJECT SPECIAL PROVISIONS. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR THEIR INTERPRETATION OF THE FINDINGS PRESENTED IN THE REPORTS. THE REPORTS SHALL NOT BE CONSIDERED TO BE PART OF THE CONTRACT DOCUMENTS. san luis obispo county, california general notes: SEPT. 2019 SEPTEMBER 2019 1000044 DISINFECTION BYPRODUCT REDUCTION AND WATER TREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT Matt Horn, P.E.RCE 63611 City Engineer G-001 ACCESS ROAD VICINITY MAP NOT TO SCALE CLEARWELL NO 2. AND PIPE GALLERY PROJECT LOCATION GENERAL NOTES ABBREVIATIONS LEGEND EDGE OF PAVEMENT EXISTING FENCE SD SD STORM DRAIN LINE OE OVERHEAD ELECTRICAL LINE AREA LIGHT LIGHT STANDARD COMMUNICATION MANHOLE ELECTRICAL MANHOLE FIRE HYDRANT GAS METER ELECTRIC METER WATER METER GAS VALVE IRRIGATION CONTROL VALVE WATER VALVE GUY POLE GUY WIRE JOINT UTILITY POLE POWER POLE BRUSH LINE/DRIP LINE RIGHT-OF-WAY LINE G SS w T UNDERGROUND GAS PAINT MARK SANITARY SEWER PAINT MARK WATER PAINT MARK UNDERGROUND TELEPHONE PAINT MARK TELEPHONE POLE POLE WITH LIGHT APPROXIMATE PROPERTY LINE EASEMENT LINE TRAFFIC STRIPING C E UNDERGROUND ELECTRIC PAINT MARK E GM JP PP TP WM GV ICV EM PP 20" PINE TREE WITH DIAMETER NOTED UNDERGROUND FIBER OPTIC PAINT MARKFO TRAFFIC SIGNAL BOXTSB ARV AIR RELEASE VALVE IRR IRRIGATION PIPE VALVE B-1 C-1 SOIL BORING LOCATION & NUMBER PER PROJECT GEOTECHNICAL REPORT SOIL CPT LOCATION & NUMBER PER PROJECT GEOTECHNICAL REPORT OIL OIL PIPE LINE E UNDERGROUND ELECTRICAL LINE SANITARY SEWER LINE GAS LINE AT&T LINE NEW PIPELINE CENTERLINE EXISTING GROUND SURFACE (PROFILE VIEW) SURVEY CONTROL POINT AND NUMBER FOUND MONUMENT AS DESCRIBED (SEE MONUMENT TABLE) 1 1 GAS MANHOLE STORM DRAIN MANHOLE SANITARY SEWER MANHOLE ELECTRICAL BOX GAS BOX STREET LIGHT BOX TELEPHONE BOX BOLLARD/SMALL POLE SANITARY SEWER CLEAN OUT MONITORING WELL STREET SIGN/SIGN POST MAIL BOX ELEC MW CO TEL G S GAS SLB FIBER OPTIC PLACARDFO GAS PLACARDG AGENCY/UTILITY AGENCY CONTACT PHONE NUMBER AT&T RALPH SOARES (805) 546-7315 PG&E DEBBIE BITTICK (805) 546-5257 SOUTHERN CALIFORNIA GAS COMPANY CLAUDIA TURNER (805) 781-2429 UNDERGROUND SERVICE ALERT 811 AC ASPHALTIC CONCRETE ARV AIR RELEASE VALVE AVV AIR VACUUM VALVE BV (BFV) BUTTERFLY VALVE ℄CENTERLINE CAV COMBINATION AIR VALVE CF CUBIC FEET CI CAST IRON DIA. (Ø) DIAMETER DIP DUCTILE IRON PIPE EC END OF CURVE EL ELEVATION EPDM ETHYLENE PROPYLENE DIENE MONOMER EXIST.(E) EXISTING FBEL&C FUSION BONDED EPOXY LINED AND COATED FLG FLANGE FL FLOW LINE FCTF FIELD CUT TO FIT FO FIBER OPTIC GE GROOVED END GRS GALVANIZED RIGID STEEL POTHOLE NUMBER/LOCATION1 NEW SAMPLING STATION NEW CAV NEW BLOWOFF VALVE NEW ARV NEW AVV ID INTERNAL DIAMETER LBS POUNDS MG MILLION GALLON MJ MECHANICAL JOINT O.C. ON CENTER PD PLANT DRAIN PC POINT ON CURVE PCC PORTLAND CONCRETE PAVEMENT PE PLAIN END PH POTHOLE PI POINT OF INFLECTION PL PROPERTY LINE PP POWER POLE PRV PRESSURE REDUCING VALVE PVC POLYVINYL CHLORIDE R/W RIGHT-OF-WAY SD STORM DRAIN SS (SST) STAINLESS STEEL SS SANITARY SEWER STA STATION THM TRIHALOMETHANE TS TRAFFIC SIGNAL TYP. TYPICAL THRUST BLOCK SS12 ABANDONED SANITARY SEWER LINE NEW FENCE 1. CONTRACTOR TO COMPLY WITH THE REQUIREMENTS OF THE CALIFORNIA STATE WATER RESOURCES CONTROL BOARD (SWRCB) AND CITY STANDARD SPECIFICATIONS. 2. PROJECT DRIVEWAYS AND CONSTRUCTION ENTRANCES SHALL BE PROTECTED AGAINST EROSION AND TRACKING OF MUD AND DEBRIS AT ALL TIMES, INCLUDING EVENINGS, WEEKENDS AND HOLIDAYS. SUCH PROTECTION MAY BE MODIFIED TO PROVIDE ACCESS TO THE WORK SITE DURING WORK HOURS. 3. WASTE MATERIALS SHALL NOT BE WASHED OFFSITE. THIS INCLUDES BUT IS NOT LIMITED TO SOIL, PAINT, GROUT, COLOR COAT, CONCRETE DUST, SAW RESIDUES, GRINDINGS, AND OIL. 4. THE CONTRACTOR IS RESPONSIBLE FOR THE PLACEMENT OF EROSION CONTROL DEVICES IN ACCORDANCE WITH THE CITY'S STANDARDS AND SWRCB REQUIREMENTS. EROSION CONTROL NOTES NEW PLUG VALVE CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY G-002 2 LEGEND, ABBREVIATIONS, AND NOTESJEH JPF --- --- AS NOTED ON PLANS 1. VERIFY DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING WORK. ANY CONFLICTS BETWEEN DETAILS OR DIMENSIONS ON THE DRAWINGS SHALL BE REPORTED PROMPTLY TO THE OWNER. 2. TAKE PRECAUTIONARY MEASURES TO PROTECT UTILITIES AND STRUCTURES SHOWN AS WELL AS ANY AND ALL OTHERS NOT ON RECORD DRAWINGS OR NOT SHOWN ON THESE PLANS. ALL SUCH IMPROVEMENTS OR STRUCTURES DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR RECONSTRUCTED TO ORIGINAL DESIGN CONDITION AND/OR THE APPLICABLE REQUIREMENTS OF THE AFFECTED UTILITY AT THE CONTRACTOR'S EXPENSE. APPROVAL BY CITY SHALL ALSO BE REQUIRED. 3. COORDINATE UNDERGROUND UTILITY MARKING WITH THE LOCAL UNDERGROUND SERVICE ALERT JURISDICTION (CALL 811) PRIOR TO CONSTRUCTION. 4. VERIFY LOCATIONS AND DEPTHS OF EXISTING UTILITIES BEFORE BEGINNING CONSTRUCTION UNLESS NOTED ON PLANS. LOCATIONS SHOWN ON THESE PLANS ARE APPROXIMATE AND FOR GENERAL INFORMATION ONLY. 5. UPON LEARNING OF THE EXISTENCE AND LOCATIONS OF ANY UNDERGROUND FACILITIES NOT SHOWN OR SHOWN INACCURATELY ON THESE PLANS OR NOT PROPERLY MARKED BY THE UTILITY OWNER, IMMEDIATELY NOTIFY THE OWNER. 6. USE EXTREME CAUTION WHEN WORKING NEAR OVERHEAD OR UNDERGROUND POWER, GAS, OR OTHER UTILITIES SO AS TO SAFELY PROTECT ALL PERSONNEL AND EQUIPMENT. PROTECT FROM DAMAGE INCURRED DURING CONSTRUCTION ALL OVERHEAD UTILITY LINES WHETHER SHOWN OR NOT SHOWN ON THESE PLANS. NOTIFY UTILITY COMPANIES PRIOR TO ANY WORK IN OVERHEAD LOCATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR COST INCURRED. 7. PRESERVE ALL SURVEY MARKERS AND MONUMENTATION. THOSE REQUIRING REMOVAL SHALL BE TIED OUT; A CORNER RECORDED; AND RE-ESTABLISHED IN ACCORDANCE WITH THE LOCAL GOVERNING AUTHORITY AND CITY STANDARDS. 8. MAINTAIN SITE SECURITY AND OWNER ACCESS THROUGHOUT CONSTRUCTION. 9. ALL SPECIFICATIONS, DRAWINGS, AND DETAILS INCLUDED IN THE CONTRACT DOCUMENTS SHALL FULLY APPLY TO THE WORK WHETHER SPECIFICALLY REFERENCED OR NOT. 10. PROVIDE VIDEO DOCUMENTATION OF THE PRE-EXISTING CONDITIONS OF THE PROJECT SITE AND SURROUNDING AREA. SUBMIT THE VIDEO TO THE CITY PRIOR TO THE START OF CONSTRUCTION. 11. MAINTAIN THE WORK AREA IN A NEAT, CLEAN, AND SANITARY CONDITION AT ALL TIMES AND TO THE SATISFACTION OF THE CITY. STREETS SHALL BE KEPT CLEAN OF DEBRIS, WITH DUST AND OTHER NUISANCES BEING CONTROLLED AT ALL TIMES. 12. MAINTAIN A COMPLETE AND ACCURATE RECORD OF ALL CHANGES IN CONSTRUCTION FROM THAT SHOWN IN THESE PLANS AND SPECIFICATIONS FOR THE PURPOSE OF PROVIDING A BASIS FOR RECORD DRAWINGS. THE CONTRACTOR SHALL NOTE DEVIATIONS FROM THE PLANS ON A SET OF PLANS SPECIFICALLY SET ASIDE FOR THIS PURPOSE. ANY CHANGES SHALL BE MADE ON THE ORIGINALS OF THE PLANS. NO CHANGES FROM THAT SHOWN ON THESE PLANS AND SPECIFICATIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE OWNER'S REPRESENTATIVE. 13. RESTORE ALL PAVEMENT, CONCRETE, ASPHALT, SIDEWALKS, CURBS, TRUNCATED DOMES, AND DRIVEWAY SURFACES REMOVED OR DAMAGED DURING CONSTRUCTION UNLESS INDICATED OTHERWISE ON THE PLANS. PAVEMENT, DRIVE APPROACH, AND SIDEWALK RESTORATION SHALL BE PER CITY STANDARDS. OTHER SURFACES SHALL BE RESTORED IN-KIND UNLESS INDICATED OTHERWISE. 14. CONSTRUCTION ACTIVITIES SHALL BE LIMITED TO THE HOURS REFERENCED IN THE CITY'S SPECIAL PROVISIONS AND AS LIMITED BY LOCAL ORDINANCE. 15. ALL FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF SAN LUIS OBISPO STANDARDS AND SPECIFICATIONS, UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS. 16. LIMIT CONSTRUCTION ACTIVITIES TO THE RIGHT-OF-WAY, EASEMENTS, AND DESIGNATED AREAS SHOWN ON DRAWINGS. 17. FURNISH AND MAINTAIN CHEMICAL TOILETS FOR USE BY WORKERS AND SUBCONTRACTORS. PROJECT NOTES 1. CERTAIN HAZARDS EXIST, INCLUDING BUT NOT LIMITED TO THE PRESENCE OF LEAD-BEARING COATINGS, AND RISKS ASSOCIATED WITH FAILURE OF EXISTING 30" FILTER EFFLUENT PIPE. CONTRACTOR SHALL SUBMIT HEALTH AND SAFETY PLAN PER CITY STANDARD 14-11.01A. 2. THE WATER SYSTEM SHALL BE HYDROSTATICALLY TESTED PRIOR TO SURFACE RESTORATION PER STANDARD SPECIFICATION SECTION 77. TEST PRESSURE SHALL BE 125 PSI. 3. WATER LINES SHALL HAVE A MINIMUM COVER OF 36 INCHES, UNLESS OTHERWISE NOTED. 4. FLUSH AND DISINFECT LINES PER STANDARD SPECIFICATION SECTION 77 AND AWWA C651 PRIOR TO PRESSURE TESTING. 5. NOTIFY CITY 72 HOURS PRIOR TO INTERRUPTION OF WATER SERVICE. CITY SHALL BE RESPONSIBLE FOR OPERATION OF ALL CITY WATER VALVES. 6. CONTRACTOR SHALL OPEN ALL TANK SIDE MANWAYS FOR ACCESS. TWO MANWAYS EXIST ON CLEARWELL #2. ONE MANWAY EXISTS ON EDNA SADDLE TANK. 7. CERTAIN EQUIPMENT IS NAMED "NO EQUAL". REFER TO SPECIFICATION SECTION 011100. FIBER OPTIC LINE WATER PIPELINE TTHM STAGING AREA SITE ACCESS STENNER CREEK RDWATER TREATMENT PLANT 2 MG CLEARWELL NO. 2 WATER LAB FOR THM ANALYZER PIPE GALLERY PIPE GALLERY STAGING AREA SITE ACCESS 4 MG EDNA TANK BLUEROCK DR. STONERIDGE DR.BROAD ST .ROCKVIEW PL . GATE CONTRACTOR LAYDOWN BEHIND GATE SHALL NOT IMPEDE CITY ACCESS AROUND TANK SITE GATE CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY G-003 3 AREA MAPSJEH JPF --- --- AS NOTED ON PLANS AREA MAP - CLEARWELL No.2 AND PIPE GALLERY SCALE: 1" = 100' 1 - AREA MAP - EDNA TANK SCALE: 1" = 150' 2 - (E) ANODE HANDHOLE, TYP (E) OVERFLOW (E) CONTROL PANEL (CSP-8) (E) TRANSFER PUMP STATION BUILDING (E) MOTOR CONTROL CENTER (MCC-6) (E) TETHER POINT TYP 3 1 2 4 (E) ANODE HANDHOLE, TYP. TYP. EQUIPMENT PAD PER DETAIL 2 - 30" MONOBOLT MANWAY 30" MONOBOLT MANWAY 20.0°(E) OUTLET (E) LADDER 5 5 (E) INLET (E) ROOF HATCH AND GUARD RAIL10' MIN.MAINTAIN MINIMUM 10' SEPARATION BETWEEN (E) ANODES AND CENTER OF AERATOR INLET, TYP. SEE GENERAL NOTE 2 (E) ANODE HANDHOLE, TYP. #4@ 12" oc 6"3"3" TYP 12" CHAMFER ALL AROUND 3 1 3 2 CONCRETE SHALL BE CLASS "A" REINFORCING STEEL SHALL BE GRADE 60 ASTM A615 GROUND CONDUCTOR IN SLAB3 2 1 NOTES: 00 10'20' 1" = 10' CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-110 4 CLEARWELL NO. 2SITE PLANJEH JPF --- AS NOTED ON PLANS SITE PLAN SCALE: 1" = 10' 1 - MATERIAL LIST ITEM DESCRIPTION FURNISH AND INSTALL ROOF MOUNTED POWER VENT, SEE SHEET S-102 FURNISH AND INSTALL PAX WATER MIXER (PWM 400 V3) ON FLOOR OF TANK. MIXER SHALL BE SUPPLIED WITH MIXER CONTROL PANEL. CABLE SHALL BE INSTALLED PER ELECTRICAL DRAWINGS. LOCATION OF JUNCTION BOXES AND CONDUIT SHALL NOT IMPEDE INTERIOR LADDER ACCESS. FURNISH AND INSTALL THM REMOVAL SYSTEM CONTROL PANEL. FURNISH AND INSTALL SOFTWARE REQUIRED TO ACCEPT ACTIVE FEEDBACK CONTROL FROM ONLINE THM ANALYZER. FURNISH AND INSTALL SEVEN (7) AERATORS. SEE SHEET C-111. FURNISH AND INSTALL TWO (2) NEW EPDM C-RING MANWAY GASKETS. 14" x 29" I.D., 60 DURO-HARD OR APPROVED EQUAL 1 2 3 4 5 GENERAL NOTES: 1. THE OWNER WILL DRAIN TANK TO WITHIN 3 INCHES OF THE FLOOR PRIOR TO CONSTRUCTION. WASH INSIDE OF TANK AND REMOVE SEDIMENT PER AWWA M42 AND SPECIFICATION SECTION 099674. 2. LOCATION OF AERATORS SHOWN IS APPROXIMATE. FINAL LOCATION OF AERATORS TO BE DETERMINED DURING CONSTRUCTION TO COORDINATE WITH EXISTING TANK ELEMENTS (ANODES, RAFTER LOCATIONS, ETC). 3. VERIFY DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING WORK. ANY CONFLICTS BETWEEN DETAILS OR DIMENSIONS ON THE EXHIBITS SHALL BE REPORTED PROMPTLY TO THE OWNER'S REPRESENTATIVE. 4. CONTRACTOR TO MAINTAIN OWNER ACCESS TO ALL FACILITIES AT ALL TIMES. 5. PREVENT DEBRIS FROM CONSTRUCTION ACTIVITIES FROM DAMAGING TANK FLOOR THROUGH THE USE OF TARPS OR OTHER FLOOR COVERING. REPAIR ANY DAMAGE TO EXISTING COATINGS RESULTING FROM CONSTRUCTION ACTIVITIES PER SPECIFICATION SECTION 099674 AS DETERMINED BY ENGINEER. 6. REMOVE ALL DEBRIS FROM CONSTRUCTION ACTIVITIES PRIOR TO DISINFECTION. 7. DISINFECT PER SPECIFICATION SECTION 099674. CONTROL PANEL PAD DETAIL SCALE: 1" = 2' 2 - (AERATOR) (INTAKE) (TANK FLOOR) (WATER LEVEL) CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-111 5 CLEARWELL No.2PSI WATER TECHNOLOGIESSURFACE AERATOR DETAILSJEH JPF --- --- AS NOTED ON PLANS MAGNETIC MOUNT CABLE INSTALLATION DETAIL NOT TO SCALE 1 - AERATOR INSTALLATION ELEVATION AERATOR INSTALLATION PLAN COAT EXPOSED STEEL SURFACE PER SPECIFICATION SECTION 099674 85"Ø (SPACING BETWEEN GUIDES) SURFACE AERATOR MAGNETIC TOP MOUNT AND GASKET MAGNETIC BASE MOUNT (E) PVC WATER SUPPLY FROM CLEARWELL NO. 2 (E) SHUT OFF VALVE (E) 1/4" STAINLESS STEEL TUBING FURNISH AND INSTALL 304 STAINLESS STEEL TEE AND SHUT OFF VALVE (E) 1/4" STAINLESS STEEL TUBING FURNISH AND INSTALL 1/4" 304 STAINLESS STEEL TUBING TO THM ANALYZER (E) SAMPLE SINK (E) UTILITY TABLE (E) SINK TO LEACH FIELD FURNISH AND INSTALL 1/4" 304 STAINLESS STEEL TUBING CONNECTED TO CLEARWELL NO. 2 SAMPLE LINE PER DETAIL FURNISH AND INSTALL 1/4" 304 STAINLESS STEEL TUBING. CONNECT TO (E) DRAIN. SECURE TO WALL EVERY 2 FEET. ATTACH 1/8" DRAIN TUBING TO THM-100 PER MANUFACTURER'S RECOMMENDATIONS FURNISH AND INSTALL ROLAIR JC10PLUS AIR COMPRESSOR WITH INGERSOLL RAND 115V/ 1/4 INCH, 1 GPM AUTO DRAIN VALVE. FURNISH AND INSTALL POLYURETHANE TUBING FITTED WITH 12" BARBED FITTING ONTO AUTO DRAIN VALVE WITH HOSE CLAMP (N) THM ANALYZER AND GRAB SAMPLE BOX. SEE THIS SHEET DETAIL FURNISH AND INSTALL 1/4" 304 STAINLESS STEEL SAMPLE TUBING SECURE TO WALL EVERY 2 FEET. TRANSITION TO 1/8" TUBING PER MANUFACTURER'S RECOMMENDATIONS (E) FUME HOOD 5 - CONNECT BOTH DRAIN LINES TO (E) SINK DRAIN. DO NOT COMBINE DRAIN LINES PRIOR TO SINK DRAIN PER DETAIL 1/2 INCH POLYURETHANE TUBING TO (E) DRAIN CONNECT TO THM-100 PER MANUFACTURER'S RECOMMENDATIONS (N) SAMPLE BOOST PUMP 2 - 3 - (E) DEMO AREA 1 - DEMO (E) COUNTER TOP AND SHEET METAL BACK PLATE (E) 32" (E) WINDOW FURNISH AND INSTALL AMS THM-100 METER, NO EQUAL. SEE SPECIFICATION SECTION 011100 (N) REMOTE SAMPLE UNIT (N) SAMPLE BOOST PUMP CONNECT PER MANUFACTURER'S RECOMMENDATION FURNISH AND INSTALL UNISTRUT BRACING BETWEEN EXISTING WALL STUDS AS REQUIRED SUPPORT EQUIPMENT WITH MANUFACTURER FURNISHED UNISTRUT SUPPORTS REMOVE SHEET METAL FLOOR AND LOCATE COMPRESSOR DIRECTLY ON FLOOR CUT 8'x8" HOLE IN (E) DOOR. FURNISH AND INSTALL 8"x8" NOMINAL ALUMINUM EGG CRATE GRILLE, SURFACE MOUNT, BOTH SIDES.12" GRID WITH POWDER COAT FINISH. PRICE GRILLES, SERIES 80 OR APPROVED EQUAL SAMPLE TUBING MODIFY SINK DRAIN PIPING AS NECESSARY TO ACCOMMODATE NEW DRAIN TUBING CONNECTIONS 14" SS DRAIN TUBING FROM THM-100 12" POLYURETHANE TUBING FROM COMPRESSOR DRAIN SERVICE SADDLE SMITH BLAIR TYPE 315 WITH 1 2" NPT TAP, OR EQUAL 12" BRONZE BARBED FITTING W/SS HOSE CLAMP 12" x 14" NYLON INSULATING BUSHING14" 304 SS FERRULE x 14" NPT PARKER OR EQUAL NEW ABS PIPE CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-112 6 CLEARWELL No.2THM ANALYZERSITE PLANJEH JPF --- --- AS NOTED ON PLANSTHM ANALYZER NOT TO SCALE 5 - CONNECTION TO SINK DRAIN NOT TO SCALE 3 - WTP LABORATORY DEMOLITION PLAN NOT TO SCALE 1 - CLEARWELL 2 SAMPLE LINE CONNECTION NOT TO SCALE 2 - THM ANALYZER LOCATION AND PIPING LAYOUT SCALE: 1" = 20' 4 - (E) 240V PANEL B (E) SCADA CONTROL PANEL (E) TANK VENT (E) TOP HATCH 2 (E) 30"Ø MANWAY 5 (E) EXTERNAL LADDER AND CAGE 1 12' ACCE S S ROAD (E) 240V SERVICE 1 C-121 6 3 4 8 7 5 MOUNTING HOOK FOR MIXER CABLE ISOLATION KIT 00 10'20' 1" = 10' CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-120 7 EDNA TANKSITE PLANJEH JPF --- --- AS NOTED ON PLANS SITE PLAN SCALE: 1" = 10' 1 - MATERIAL LIST ITEM DESCRIPTION FURNISH AND INSTALL ROOF MOUNTED POWER VENT PER DETAIL SEE STRUCTURAL SHEET S-201 FOR REINFORCEMENT AND POWER VENT DETAILS. INSTALL PER MANUFACTURER'S RECOMMENDATION. DEMOLISH AND DISPOSE OF (E) INTERNAL LADDER AND CAGE. FURNISH AND INSTALL NEW INTERNAL FRP LADDER PER DETAIL REPAIR COATING PER 099674. INSTALL PAX WATER MIXER (PWM 400 V3) ON FLOOR OF TANK. EXTERIOR CABLE AND CHEMICAL TUBING SHALL BE INSTALLED IN CONDUIT PER ELECTRICAL DRAWINGS. LOCATION OF JUNCTION BOXES AND CONDUIT SHALL NOT IMPEDE LADDER ACCESS. FURNISH AND INSTALL MIXER CABLE MOUNTING HOOK ON INSIDE OF HATCH OPENING PER DETAIL FURNISH AND INSTALL NEW NSF-61 COMPLIANT MANWAY GASKET. RE-USE EXISTING BOLTS. CHLORINE SAMPLE RETURN LINE PER DETAIL ROUTE AND CONNECT (E) POLYETHYLENE CHLORINE TUBING TO CHLORINE INJECTION STEM ON MIXER ASSEMBLY. REMOVE (E) VENT CAP. PREP AND RECOAT PER SPECIFICATION SECTION 099674. FURNISH AND INSTALL NEW 316 SS SCREEN. REPLACE IN KIND. REPLACE HARDWARE IN KIND. 1 2 3 4 5 6 7 8 GENERAL NOTES: 1. OWNER WILL DRAIN TANK TO WITHIN 3 INCHES OF FLOOR PRIOR TO CONSTRUCTION. WASH INSIDE OF TANK AND REMOVE SEDIMENT PER AWWA M42 AND SPECIFICATION SECTION 099674. 2. VERIFY DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING WORK. ANY CONFLICTS BETWEEN DETAILS OR DIMENSIONS ON THE EXHIBITS SHALL BE REPORTED PROMPTLY TO THE OWNER'S REPRESENTATIVE. 3. CONTRACTOR TO MAINTAIN OWNER ACCESS TO ALL FACILITIES AT ALL TIMES. 4. PREVENT DEBRIS FROM CONSTRUCTION ACTIVITIES FROM CONTACTING TANK FLOOR THROUGH THE USE OF TARPS OR OTHER FLOOR COVERINGS. REPAIR ANY DAMAGE TO EXISTING COATING RESULTING FROM CONSTRUCTION ACTIVITIES PER SPECIFICATION SECTION 099674 AS DETERMINED BY ENGINEER 5. REMOVE ALL DEBRIS FROM CONSTRUCTION ACTIVITIES PRIOR TO DISINFECTION. 6. DISINFECT TANK PER SPECIFICATION SECTION 099674. 7. REPAIR ALL COATING AFFECTED BY CONSTRUCTION PER SPECIFICATION SECTION 099674. 1 S-201 1 C-122 2 - 2 C-121 NOTES: 1. FURNISH AND INSTALL 304 SS 3/8-16 WIRE TURNED OPEN EYE BOLT. 112-INCH THREAD LENGTH, 3-INCH OVERALL LENGTH. 2. FURNISH AND INSTALL DIELECTRIC ISOLATION KIT CONSISTING OF FULL-LENGTH 132 THICK MYLAR SLEEVE EXTENDING HALFWAY INTO BOLT STAINLESS STEEL WASHERS, AND TWO 18 THICK GLASS CLAD PHENOLIC ISOLATING WASHERS. PIPELINE SEAL AND INSOLATOR, INC. OR APPROVED EQUAL. CABLE MOUNTING HOOK NOT TO SCALE 2 - SAW CUT 12" WIDE TRENCH FOR SAMPLE AND RETURN LINES. BURY 12" DEEP. REPAIR CONCRETE SURFACES WITH REPAIR CONCRETE AND BONDING PRIMER TANK WALL TANK RING 1"Ø CHLORINE SAMPLE LINE 2 - CHLORINE SAMPLE LINE PER DETAIL 1 C-124 PRESSURE TRANSDUCER PER DETAIL EDGE OF CONCRETE (E) SERVICE SADDLE (E) PRESSURE TRANSDUCER AND HOSE BIBB 2 (E) 12" FLEX COUPLING WITH RESTRAINING RODS (E) 12" GATE VALVE 1 FURNISH AND INSTALL NEW 1" HALF COUPLING ON TANK WALL PER DETAIL RELOCATE (E) PRESSURE TRANSDUCER AND PLUG (E) SERVICE SADDLE WITH BRASS PLUG. REPAIR COATING ON TANK INTERIOR AND EXTERIOR PER SPECIFICATION SPECIFICATION 099674 1 C-124 (E) CONDUITS 10'-0" MIN. 2 - CHLORINE SAMPLE RETURN LINE PER DETAIL 1"Ø CHLORINE SAMPLE RETURN LINE 3 (E) CHLORINE FEED PUMP AND STORAGE TANK VFD AND PASSIVE FILTER PPV400 CONTROL CENTER 2 C-124 WALL PENETRATION PER DETAIL TYP. 1"Ø CHLORINE SAMPLE LINE 1"Ø CHLORINE SAMPLE RETURN LINE 4 5 METER DRAIN TUBING (E) PANEL BPWM500 CONTROL CENTER TANK SHELL INSIDE DIAMETER TANK FLOOR CONCRETE FOUNDATION 112" HALF COUPLING 1"x112" DIELECTRIC REDUCING BUSHING 1" TYPE K SOLDERED COPPER PIPE 1" BRONZE BALL VALVE PER SPECIFICATION SECTION 400520 1" BRONZE UNION 316 SS UNISTRUT WITH CLAMP AND INSULATING SLEEVE 12"MIN.TO CHLORINE ANALYZER 2'-0" (TYP.)CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-121 8 EDNA TANKENLARGED SITE PLAN AND PIPING PLANJEH JPF --- --- AS NOTED ON PLANS CHLORINE SAMPLE RETURN LINE NOT TO SCALE 2 - ENLARGED SITE PLAN SCALE: 1/2" = 1'-0" 1 - MATERIAL LIST TAG DESCRIPTION REPLACE EXISTING 12" FLGxMJ GATE VALVE PER CITY STANDARD 77-2.02 D(1). RELOCATE EXISTING PRESSURE TRANSDUCER PER PLANS AND DETAIL INSTALL OWNER FURNISHED PUMP AND MOTOR (GRUNDFOS 5015-9/0 KP). FURNISH AND INSTALL PUMP ENCLOSURE PER SHEET S-201 CHEMTRAC HYDRO ACT HA4+FCL ANALYZER, NO EQUAL. SEE SPECIFICATION SECTION 0111100. SEE BURT PROCESS PES-30-DB6-S TRANSFER STATION, NO EQUAL. SEE SPECIFICAITON SECTION 011100. SEE 1 2 3 4 5 1 C-124 CHLORINE SAMPLE LINE AND 1 C-123 1 C-123 NOTES: 1. OWNER WILL DRAIN TANK TO WITH 3 INCHES OF FLOOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL REMOVE SEDIMENT FROM TANK FLOOR. IT IS ESTIMATED 3 4" OF SEDIMENT EXISTS. 2. PRESSURE TEST AND DISINFECT PIPING PER CITY STANDARD 77 35'-6 9/16"FIELD VERIFYROOF HATCH 2'-8"1'-0"TANK FLOOR A A1'-0"TYP.FRP SIDE RAILS FRP LADDER 2 - 316 SS CABLE CLIMBING SAFETY SYSTEM AND REMOVABLE EXTENSION, MILLER Vi-Go OR APPROVED EQUAL. PROVIDE CABLE, TOP AND BOTTOM BRACKET ASSEMBLIES, CONTINUOUS CABLE GUIDES, CABLE SLEEVE, AND ALL APPURTENANCES. 4'-6" REMOVABLE EXTENSION 4 - LADDER SUPPORT TO SHELL CONNECTION 3 - UPPER LADDER CONNECTION DETAIL 114"Ø SOLID RUNG WITH FLUTED, SKID RESISTANT SURFACE TYPICAL LADDER SUPPORT PER DETAIL NUMBER AND DIMENSIONS TO BE DETERMINED BY CONTRACTOR PER SPECIFICATION SECTION 065000 TYP.3/16" RUNG 2 - LADDER SUPPORT PER DETAIL TYP. TANK SHELL 16" MIN. 4 - 4"x4"x 3/8" A36 FLAT BAR PER DETAIL TYP. 18"± FINAL SIZE TO BE VERIFIED BY CONTRACTOR IN FIELD ROOF HATCH 4" x 5" x 3 8" A36 FLAT BAR FURNISH AND INSTALL ISOLATION KIT, (TYP.) 3/16TYP. FRP LADDER 5"4"LADDER MOUNTING HOLES. COORDINATE WITH LADDER SIDE RAILS 1"2"18"± FINAL SIZE TO BE VERIFIED BY CONTRACTOR IN FIELD FRP CHANNEL PER SPECIFICATION SECTION 065000 MOUNTING HOLES. COORDINATE WITH DETAIL LADDER MOUNTING HOLES. COORDINATE WITH LADDER SIDE RAILS MATCH LADDER SIDE RAIL 4 - 4"4"2 1/2"2"1"9 16"Ø HOLE, 2 REQ'D 4"4" x 4" x 3 8" A36 FLAT BAR FRONT VIEW SIDE VIEW FURNISH AND INSTALL ISOLATION KIT (TYP.) CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-122 9 EDNA TANKINSIDE LADDERJEH JPF --- --- AS NOTED ON PLANS INSIDE LADDER SCALE: 1/2" = 1'-0" 1 - SECTION SCALE: 3/4" = 1'-0" A-A - FRP LADDER SUPPORT (TYPICAL) SCALE: 1-1/2" = 1'-0" 2 - UPPER LADDER CONNECTION DETAIL SCALE: 3" = 1'-0" 3 - SHELL CONNECTION PLATE NOT TO SCALE 4 - NOTES: 1. ALL UNUSED BRACKETS SHALL BE REMOVED FROM INTERIOR SURFACES. GRIND SMOOTH ALL WELDS, BURRS WELD SPLATTER, SCARS AND ROUGH EDGES. 2. FINISH ALL WELDS AND SURFACES TO BE COATED PER NACE SP0178. 3. ALL MATERIAL FOR LADDER SUPPORTS, SIDERAILS AND RUNGS TO BE FRP (FIBERGLASS). CLIMBING SAFETY DEVICES TO BE SST 316 AND SHALL BE COMPATIBLE WITH 114" DIAMETER RUNGS. 4. GRIND SMOOTH ALL EDGES. 5. USE SST 316 FOR ALL BOLTS, NUTS AND WASHERS. 6. SEAL CUT ENDS OF FRP WITH NSF 61 CERTIFIED EPOXY IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 7. LADDER BRACKETS SHALL BE CONNECTED TO LADDER WITH SST 316 CAP SCREWS WITH WASHER AND NUT. 8. LADDER BRACKET CLIPS SHALL BE CONNECTED TO LADDER BRACKET WITH SST 316 CAP SCREWS WITH WASHER AND NUT. 9. REPAIR COATINGS AFFECTED BY WORK PER SPECIFICATION SECTION 099674. 10. COAT NEW STEEL AND WELDED AREAS PER SPECIFICATION SECTION 099674. 11. ALL WELDS SHALL IN CONFORMANCE WITH AWWA D100. 12. SUBMIT DESIGN CALCULATION AND SHOP DRAWINGS PER SPECIFICATION SECTIONS 065000 AND 066010. 13. FURNISH AND INSTALL DIELECTRIC ISOLATION KITS BETWEEN STAINLESS STEEL BOLTS AND CARBON STEEL BRACKETS. ANALYZER 14" ID NSF61 CERTIFIED PVC TUBING 12" x 14" COPPER BARB 12" BRONZE BALL VALVE 1" COPPER PIPE FROM TANK 12" x 1" REDUCER 12" ID NSF61 CERTIFIED PVC TUBING TO 112" HALF COUPLING, SECURE IN PLACE 1" PVC NIPPLE 1"Ø SCH80 PVC PIPE 15 8" UNISTRUT AND PIPE CLAMPS, (TYP.) 1" PVC UNION 1"Ø COPPER PIPE TO TANK ETHERNET TO (E) SCADA. SEE ELECTRICAL SHEETS TRANSFER STATION 112" HALF COUPLING 1" PVC UNION CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-123 10 EDNA TANKTRANSFER STATIONJEH JPF --- --- AS NOTED ON PLANSTRANSFER STATION AND CHLORINE ANALYZER NOT TO SCALE 1 - PLAN VIEW ELEVATION VIEW 2 C-124 WALL PENETRATION PER DETAIL TANK SHELL RELOCATED PRESSURE TRANSDUCER 12" BRONZE UNION 12" BRONZE BALL VALVE PER SPECIFICATION SECTION 400520 12" BRONZE BALL VALVE PER SPECIFICATION SECTION 400520 AA 1" HALF COUPLING 12"Ø BRONZE NIPPLE 12"x1" DIELECTRIC REDUCING BUSHING PER AWWA D100 TURN-DOWN VENT PIPE 2x 3 8"Ø 316 SS EPOXY ANCHOR BOLTS, 3" DEEP 15 8" 316 SS UNISTRUT CHANNEL AND POST BASE 316 SS PIPE CLAMP AND INSULATING SLEEVE 12"Ø TYPE K SOLDERED COPPER, TYP. NEW FLEX CONDUIT TO EXISTING NEW 1" HALF COUPLING 2'-0"APPLY GUN GRADE ELASTOMERIC SEALANT IN ANNULAR SPACE BLOCK WALL ANNULAR SPACE 1" MIN ALL AROUND EXCEPT WHERE NOTED OTHERWISE ON DWGS PACK TIGHT LAYERS OF EXPANDED POLYETHYLENE OR POLYURETHANE ROPE TYPE FILLER CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECT0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-124 11 EDNA TANKDETAILSJEH JPF --- --- AS NOTED ON PLANS PRESSURE TRANSDUCER ASSEMBLY NOT TO SCALE 1 - PLAN SECTION A-A SLAB OR WALL PENETRATION NOT TO SCALE 2 - OZONE GENERATION BUILDING (E) ACID NEUTRALIZATION TANK (E) 4" SEWER (E) ELECTRICAL CONDUITS (E) 30"Ø STEEL FILTER EFFLUENT PIPE FILTER UNITSFLOCCULATION TANKS PIPE GALLERY TO CLEARWELL #1 P P P OZONE CONTACT BASINS (E) FILTER EFFLUENT PIPE, PLUG PER DETAIL A 30"Ø C900 PVC FILTER EFFLUENT PIPE 1 C-133 CONNECTION TO (E) EFFLUENT PIPE PER DETAIL 2 - A A B B 17'-6" FROM COLUMN CORNER P 30" TRANSITION COUPLING PER SPECIFICATION SECTION 400722. REPAIR DAMAGED CEMENT MORTAR LINING AND COATING AS NECESSARY AT CONNECTION POINT PER SPECIFICATION SECTION 402001 FABRICATED STEEL ELBOW, PExPE, FBE L&C ΔH = 60.1° ΔV = 6.4° THRUST BLOCK (25 SQ. FT.) INSTALL SACRIFICIAL ANODE FOR CATHODIC PROTECTION 30" COUPLING FOR MINOR FIT ADJUSTMENTS IF NECESSARY 1'-6"30" TRANSITION COUPLING EL=429.25 EL=427.75 3'-0"18'-10" 8'-2"' 27'-11"' S=0.00 21'-10"' EL=423.91 S=0.182 1 S=0.0338 EL=429.00 EL=434.67 EL=434.00 (E) 30"Ø STEEL PIPE TOP OF EXISTING PIPE ≈ 7'-1" BELOW EXISTING GRADE, FIELD MEASURE 30"Ø C900 PVC 30"Ø C900 PVC TOF=428.69 TOF=429.23 EL=434.00 EL=434.00 (E) A.C. PARKING 1'-3"12"4'-0" 4'-0" 13'-2"' NO EXCAVATION ALLOWED IN THIS AREA FOUNDATION ZONE OF INFLUENCE12"1 1 STRUCTURAL COLUMNS CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-130 12 PIPE GALLERYIMPROVEMENTSJJR JPF --- --- AS NOTED ON PLANS GENERAL NOTES: 1. THE OWNER WILL ALLOW A TWENTY-FOUR (24) HOUR SHUT DOWN PERIOD FOR CONNECTION TO (E) EFFLUENT FILTER PIPELINE. CONTRACTOR WILL BE RESPONSIBLE FOR DRAINING AND DISCHARCHING RESIDUAL WATER IN THE PIPELINE. 2. VERIFY DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING WORK. ANY CONFLICTS BETWEEN DETAILS OR DIMENSIONS ON THE EXHIBITS SHALL BE REPORTED PROMPTLY TO THE OWNER'S REPRESENTATIVE. 3. CONTRACTOR TO MAINTAIN OWNER ACCESS TO ALL FACILITIES AT ALL TIMES. 4. WORK PREVENTING USE OF DRIVEWAY FOR CHEMICAL DELIVERIES IS TO BE LIMITED TO TWO (2) WEEKS. 5. GROUNDWATER WILL LIKELY BE PRESENT DURING WET WINTER MONTHS. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING A DRY EXCAVATION. 6. TRENCH BACKFILL SHALL BE PER SPECIFICATION SECTION 312316 AND ENGINEER STANDARD 6020. 7. DISINFECT AND PRESSURE TEST PIPING PER STANDARD SPECIFICATION SECTION 77, TEST PRESSURE SHALL BE 125 PSI. SWAB EXISTING PIPING AND CONNECTION FITTINGS AT TIE-IN LOCATION PER AWWA C651. 8. RESTORE ALL PAVEMENT PER CITY STANDARDS. SITE PLAN SCALE: 1" = 20' 1 - LEGEND PROTECT IN PLACE ABANDON IN PLACE P A NEW EFFLUENT PIPE - SECTION A-A SCALE: 1" = 10' A - CONNECTION TO (E) EFFLUENT PIPELINE SCALE: 1" = 10' 2 - NEW EFFLUENT PIPE - SECTION B-B SCALE: 1" = 10' B - NOTE: CONTRACTOR TO VERIFY REQUIRED FABRICATED ELBOW ANGLES OF CONNECTION A MINIMUM OF TWO (2) DAYS PRIOR TO TIE-IN ACTIVITIES. FILTER NO 1 FILTER NO 2 FILTER NO 3 FILTER NO 4 CUT AND REMOVE (E) 24" STEEL PIPE RELOCATE FILTER INSTRUMENTS AND BACKBOARD, SEE SHEET C-132 REMOVE (E) WINDOW, SEE STRUCTURAL SHEET S-104 REMOVE (E) CONCRETE STAIRS. SEE STRUCTURAL SHEET S-104 DISCONNECT (E) CHEMICAL INJECTION LINES, CUT AND REMOVE (E) 30" STEEL PIPE PIPE GALLERY A - B - PLUG (E) 30" STEEL LINE PERA1 C-133 (E) 24"Ø EFFLUENT FILTER LINE (E) 24"Ø WASHWATER INFLUENT LINE (E) PRESSURE GAUGE AND VALVES ON SODIUM HYPOCHLORITE, RELOCATE AS SHOWN ON C-132 (E) 24" BUTTERFLY VALVE, SEE CONSTRUCTION SEQUENCING NOTES: 1. (E) 30"Ø WASHWATER DRAIN PIPING NOT SHOWN FOR CLARITY 2. PROVIDE TEMPORARY STAIRS FOR OPERATOR ACCESS DURING CONSTRUCTION AND EMERGENCY EGRESS. REMOVE (E) 3 4" PVC SODIUM HYDROXIDE PIPE (E) ELECTRICAL JUNCTION BOX P (E) 24"Ø EFFLUENT FILTER LINE (E) 4" CI DRAIN LINE REMOVE VALVE AND ASSOCIATED GALVANIZED PIPE REMOVE PIPING UP TO GROOVED END COUPLING. PROTECT IN PLACE (E) 14" FILTER NO 2 DISCHARGE PIPING REMOVE (E) 3" PVC VENT PIPE TO WINDOW PENETRATION CUT AND REMOVE (E) 30" STEEL PIPE (E) 24" BUTTERFLY VALVE, SEE CONSTRUCTION SEQUENCING CUT AND REMOVE (E) 24" STEEL PIPE P P P (E) 30"Ø WASHWATER DRAIN PIPING NOT SHOWN FOR CLARITY PIPE GALLERY (E) 30"Ø WASH WATER DRAIN LINE (E) 24"Ø EFFLUENT LINE (E) 24"Ø WASH WATER INFLUENT LINE REMOVE SLAB PER STRUCTURAL SHEET S-202 (E) 4" CI DRAIN PIPE CASED IN CONCRETE P P P CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-131 13 PIPE GALLERYDEMOLITION PLANJJR JPF --- --- AS NOTED ON PLANS DEMOLITION NOTES: 1. IT IS ANTICIPATED THAT THE EXISTING 24" BUTTERFLY VALVE WILL BE USED TO ISOLATE FILTERS 1 AND 2 AND TO CONSTRUCT NEW FILTER EFFLUENT LINE. CONTRACTOR TO INSTALL TEMPORARY 24" BULKHEAD PLUG. 2. CONTRACTOR MAY INSTALL TEMPORARY BEAMS WITHIN PIPE GALLERY FOR USE TO INSTALL/REMOVE PIPING AND VALVES. CONTRACTOR TO SUBMIT PLAN INCLUDING DESIGN CALCULATIONS STAMPED BY CALIFORNIA LICENSED STRUCTURAL ENGINEER SEVEN (7) DAYS PRIOR TO PERFORMING WORK. 3. CONCRETE TO BE REMOVED WITH USE OF SAW CUTTING OR SIMILAR TECHNIQUES. JACK HAMMERS WILL NOT BE ALLOWED. SECTION VIEW SCALE: 1/4" = 1'-0" B - SITE PLAN SCALE: 1/4" = 1'-0" 1 - SECTION VIEW SCALE: 1/4" = 1'-0" A - LEGEND PROTECT IN PLACE ABANDON IN PLACE P A SUGGESTED CONSTRUCTION SEQUENCING: STEP 1: CLOSE ISOLATION VALVE ON EFFLUENT FILTER MANIFOLD LOCATED BETWEEN FILTERS 2 AND 3. CITY WILL OPERATE FILTERS 1 AND 2. STEP 2: CONSTRUCT NEW EFFLUENT FILTER CONNECTION IN PIPE GALLERY AND UP TO CONNECTION POINT OUTSIDE OF BUILDING. STEP 3: CONNECT NEW EFFLUENT FILTER PIPE TO (E) EFFLUENT FILTER PIPE OUTSIDE OF BUILDING AND REPLACE ISOLATION VALVE. STEP 4: CITY TO OPERATE FILTERS 3 AND 4. REMOVE AND REPLACE (E) 30" TEE AND PIPING AS SHOWN IN PIPE GALLERY. TO BE DISCUSSED WITH CITY FILTER NO 1 FILTER NO 2 FILTER NO 3 FILTER NO 4 2 3 121 4 7 8 5 6 REMOVE AND REPLACE (E) PIPING WITH 24" WELDED STEEL, FUSION BONDED EPOXY LINED AND COATED PIPE GALLERY (E) 24"Ø WASHWATER INFLUENT LINE A - B C-133 13 13 NEW ALUMINUM STAIRS AND PLATFORM PER STRUCTURAL SHEET S-104 FILL SUMP AREA WITH CLASS A CONCRETE. MATCH EXISTING ELEVATIONS 16 15 (E) 24"Ø EFFLUENT FILTER LINE 17 CONNECT TO (E) 3" SCH80 PVC SODIUM SILICAFLUORIDE PIPING AND EXTEND TO CHEMICAL INJECTION POINT CONNECT TO (E) 3 4" SCH80 PVC SODIUM HYPOCHLORITE PIPING (2 PIPES) AND EXTEND TO CHEMICAL INJECTION POINT. PROVIDE SAME UNISTRUT AND VALVES AS EXISTING. SEE DETAIL CONNECT TO (E) 3/4" SCH80 PVC SODIUM HYDROXIDE PIPING AND EXTEND TO CHEMICAL INJECTION POINT (E) 3/4" SODIUM HYDROXIDE 22 9 RELOCATED PRESSURE GAUGE AND VALVES ON SODIUM HYPOCHLORITE PIPING. MOUNT ON WALL WITH UNISTRUT 11 NOTE: (E) 30"Ø WASHWATER DRAIN PIPING NOT SHOWN FOR CLARITY 18 19 (E) ELECTRICAL JUNCTION BOX. MODIFY STAIR FRAME TO FIT 2 C-135 NEW TRENCH OUTLINE 20 22 2 3 121 1'-6" 10 12 11 13 RECONNECT TO FILTER NO 2 DISCHARGE PIPING (N) 24"Ø EFFLUENT FILTER LINE (E) 30"Ø WASHWATER DRAIN PIPING NOT SHOWN FOR CLARITY 13 2'-9"14'-1" 6'-9" 21 TYP. MATERIAL LIST: ITEM DESCRIPTION 24" TRANSITION COUPLING, PER SPECIFICATION SECTION 400722 WITH HARNESS PER DETAIL 24" STEEL SPOOL FLGxPE, FBE L&C 24"x24" WELDED STEEL TEE, FBE L&C 24"x30" ECCENTRIC REDUCER, STEEL, FBEL&C 3 4" CHEMICAL INJECTION, PER DETAIL 3" CHEMICAL INJECTION, PER DETAIL 24" C900 PVC PIPE 30" C900 PVC PIPE 30" RESTRAINED FLANGE ADAPTER 14" STEEL SPOOL GE, FBE L&C 3" VENT PIPE, SCH 80 PVC 3" AIR RELEASE AND VACUUM VALVE, PER DETAIL 24" BV PER SPECIFICATION SECTION 400520 3" BALL VALVE PER SPECIFICATION SECTION 400520 SOLID DOUBLE DOOR PER STRUCTURAL SHEET S-104 RELOCATED (E) FILTER INSTRUMENTS AND BACKBOARD, PER DETAIL NEW DOOR PER STRUCTURAL SHEET S-104 2" WELD-O-LET WITH THREADED PLUG FABRICATE STEEL ELBOW, FLGxPE, FBEL&C (APPROX. 10° DEFLECTION) COAT WALLS AND FLOOR OF NEW TRENCH WITH POTA-POX N140 PER SPECIFICATION SECTION 099674. APPLY THREE COATS WITH TOTAL THICKNESS OF 18 MILS DFT. CONCRETE PIPE CRADLE PER DETAIL 24" RESTRAINED FLANGE ADAPTER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 4 C-134 4 C-134 3 C-134 1 C-135 1 C-134 X C-13X CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-132 14 PIPE GALLERYSITE PLAN AND SECTION VIEWJJR JPF --- --- AS NOTED ON PLANS SITE PLAN SCALE: 1/4" = 1'-0" 1 - SECTION VIEW SCALE: 1/4" = 1'-0" A - CONSTRUCTION NOTES: 1. SEE SHEET C-131 FOR DEMOLITION PLAN AND SUGGESTED CONSTRUCTION SEQUENCING. 2. FUSION BONDED EPOXY LINED AND COATED STEEL PIPE AND FITTINGS PER SPECIFICATION SECTION 402057. 3. C900 PVC PIPE PER SPECIFICATION SECTION 402093. 4. SCH 80 PVC CHEMICAL SUPPLY PIPING PER SPECIFICATION SECTION 402090. MOUNT PIPING ON WALL WITH UNISTRUT AND PIPE CLAMPS. SUPPORT PIPE EVERY 4 FEET MAXIMUM. 5. LABEL SCH 80 PVC CHEMICAL SUPPLY PIPING WITH CHEMICAL NAME AND ARROW. COLOR AND SIZE OF LABEL SHALL MATCH EXISTING. LABELS SHALL BE VINYL CLOTH. 3 4 8 7 5 22 229 PIPE GALLERY (E) 30"Ø WASH WATER DRAIN LINE (N) 24"Ø C900 PVC EFFLUENT LINE (E) 24"Ø WASH WATER INFLUENT LINE SEE STRUCTURAL SHEET S-202 FOR FOUNDATION MODIFICATION (E) 4" CI DRAIN PIPE CASED IN CONCRETE SEE C-130 F O R CONTINUA T I O N OF PIPING P 11 14 12 15 20 19 6 PIPE CRADLE TO EXTEND WALL TO WALL 216"EL=427.75 EL=429.25 MATERIAL LIST: ITEM DESCRIPTION 24" TRANSITION COUPLING, PER SPECIFICATION SECTION 400722 WITH HARNESS PER DETAIL 24" STEEL SPOOL FLGxPE, FBE L&C 24"x24" WELDED STEEL TEE, FBE L&C 24"x30" ECCENTRIC REDUCER, STEEL, FBEL&C 3 4" CHEMICAL INJECTION, PER DETAIL 3" CHEMICAL INJECTION, PER DETAIL 24" C900 PVC PIPE 30" C900 PVC PIPE 30" RESTRAINED FLANGE ADAPTER 14" STEEL SPOOL GE, FBE L&C 3" VENT PIPE, SCH 80 PVC 3" AIR RELEASE AND VACUUM VALVE, PER DETAIL 24" BV PER SPECIFICATION SECTION 400520 3" BALL VALVE PER SPECIFICATION SECTION 400520 SOLID DOUBLE DOOR PER STRUCTURAL SHEET S-104 RELOCATED (E) FILTER INSTRUMENTS AND BACKBOARD, PER DETAIL NEW DOOR PER STRUCTURAL SHEET S-104 2" WELD-O-LET WITH THREADED PLUG FABRICATE STEEL ELBOW, FLGxPE, FBEL&C (APPROX. 10° DEFLECTION) COAT WALLS AND FLOOR OF NEW TRENCH WITH POTA-POX N140 PER SPECIFICATION SECTION 099674. APPLY THREE COATS WITH TOTAL THICKNESS OF 18 MILS DFT. CONCRETE PIPE CRADLE PER DETAIL 24" RESTRAINED FLANGE ADAPTER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 4 C-134 4 C-134 3 C-134 1 C-135 1 C-134 X C-13X 24" MIN CONCRETE PLUG ABANDONED-IN-PLACE PIPE SECTION SAND BAG PLUG EXISTING PIPE. REMOVE AND DISPOSE OF AS NEEDED CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-133 15 PIPE GALLERYSECTION VIEW AND DETAILSJJR JPF --- --- AS NOTED ON PLANS SECTION VIEW SCALE: 3/8" = 1'-0" B - LEGEND PROTECT IN PLACEP CUT, PLUG AND ABANDON EXISTING PIPE NOT TO SCALE 1 - CONSTRUCTION NOTES: 1. SEE SHEET C-131 FOR SUGGESTED CONSTRUCTION SEQUENCING. 2. FUSION BONDED EPOXY LINED AND COATED STEEL PIPE AND FITTINGS PER SPECIFICATION SECTION 402057. 3. C900 PVC PIPE PER SPECIFICATION SECTION 402093 PIPE VENT TO FLOOR 3" FLANGE CONNECTION 3" BALL VALVE PER SPECIFICATION SECTION 400560 3" EXTRA HEAVY GALV. STEEL NIPPLE, TYP. AIR RELEASE/VACUUM VALVE PER SPECIFICATION SECTION 400560 3"Ø SCH80 PVC 1'-0"2'-0"2'-9"EL=427.75 EL=430.50 REMOVABLE ALUMINUM GRATING 6" MIN.CLEARNACEFORD FC202 SADDLE, TAP SIZED PER TABLE 1 24"Ø C900 PVC EFFLUENT PIPE HDPE TUBING AND SAFETY SPRAY SHIELD FROM CHEMICAL PIPING (E) SLAB INLET, SEE TABLE 1 STAINLESS STEEL BALL VALVE SOLUTION TUBE ADAPTER PACKING NUT WITH 300 SERIES O-RING DUAL BOLT SAF-T-LOK PLACED 180° APART (SHOWN OUT OF POSITION) ADAPTER, SEE NOTE 2 SELF SEALING E-Z RELEASE COUPLING 2 SS SAFETY CHAINS. LIMITING CHAINS PLACED 180° APART (SHOWN OUT OF POSITION) 5'-3" 3'-2" TABLE 1 - SAF-T-FLO INJECTION QUILLS INLET SIZE SERVICE SAF-T-FLO QUILL MODEL NUMBER 3/4"SODIUM HYDROXIDE EB-145-S-S-12-0-E 3/4"SODIUM HYPOCHLORITE EB-145-S-H-8-0-V 2 1/2"SODIUM SILICA-FLURORIDE HS-300-S-H-16-0-06* *INCLUDE CHECK VALVE CKV-030-C-E NOTES: 1. INJECTION QUILL SHALL BE MANUFACTURED BY SAF-T-FLO, WITH MODEL NUMBERS PER TABLE 1. 2. PROVIDE TUBING FITTING ADAPTER, PROVIDE 90° ELBOWS WHERE REQUIRED TO MEET SPACE RESTRICTIONS. 3. PROVIDE SAFETY SPRAY SHIELD PER SPECIFICATION 400780. PIPE AS SHOWN ON DRAWINGS 1/4" NEOPRENE FULL WIDTH #3 TIES, 2 MIN #5 @ 12" DOWELS W/ STD HOOK AT BOTTOM EACH SIDE. EPOXY ANCHOR INTO EXISTING SLABVARIES,SEE DRAWINGS2" MIN1"MINSUPPORT LENGTH 45°45° NOTES: 1. SUPPORT LENGTH = PIPE OD UNLESS OTHERWISE SHOWN ON THE PLANS. 2. SUPPORT WIDTH = 12". CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-134 16 PIPE GALLERYDETAILSJJR JPF --- --- AS NOTED ON PLANS AIR RELEASE VALVE DETAIL NOT TO SCALE 3 - CHEMICAL INJECTION PORT NOT TO SCALE 4 - CONCRETE PIPE SUPPORT NOT TO SCALE 1 - CITY SPECIFICATION NO. DATE:PROJECT TITLE:SHEET TITLE:of SHEET NO. 33 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: SCALE: PLAN FILE NO. / LOCATION SEPTEMBER 2019 DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENT PROJECTKnow what's below. before you dig.Call R 0 11/2 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE TBD FOR PRELIMINARY USE ONLY C-135 17 PIPE GALLERYDETAILSJJR JPF --- --- AS NOTED ON PLANS FILTER INSTRUMENTS AND BACKBOAD RELOCATION NOT TO SCALE 1 - 3 4" GROUT ALL AROUND RELOCATED FILTER INSTRUMENTS AND BACKBOARD. SEE SHEET C-132 (4)5 8"Ø MINIMUM EXPANSION ANCHORS PER POST RECONNECT FLEXIBLE CONDUIT AT TRANSITION ELBOW EXTEND SAMPLE TUBING AND CONDUIT AND RECONNECT FRONT VIEW (E) SODIUM HYPOCHLORITE CONNECTION NOT TO SCALE 2 - REAR VIEW RELOCATED FILTER INSTRUMENTS AND BACKBOARD. SEE SHEET C-132 JUNCTION BOXES WITH UNISTRUT TYPE SUPPORT (SUPPORT NOT SHOWN FOR CLARITY) REMOVE 12" COPPER PIPING AS SHOWN. INSTALL UNION AND EXTEND 12" COPPER PIPING TO RELOCATION CONNECTION POINT REMOVE RGS CONDUIT. INSTALL JUNCTION BOX AND UNSTRUT TYPE SUPPORT. INSTALL NEW RGS CONDUIT TO RELOCATED PANEL. RECONNECT POWER AND CONTROL WIRING. 3 4" POLYTUBING ADAPTER FITTING UNISTRUT SUPPORT, TYP REUSE LOCKOUT COVER 3 4" BALL VALVES RELOCATE DRAIN WITH PANEL. CONNECT TO 6" DRAIN PIPE OPENING 12"Ø COPPER PIPING CITY SPECIFICATION NO.DATE:PROJECT TITLE:SHEET TITLE:ofSHEET NO.33DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSEPTEMBER 2019DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENTS PROJECTTBDE-10027AS NOTED ON PLANSCLEARWELL NO.2 AND EDNA TANKSYMBOL LISTS, PANEL SCHEDULE AND SEISMIC NOTES CITY SPECIFICATION NO.DATE:PROJECT TITLE:SHEET TITLE:ofSHEET NO.33DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSEPTEMBER 2019DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENTS PROJECTTBDE-11028AS NOTED ON PLANSCLEARWELL NO. 2MCC-6 PARTIAL ONE LINE DIAGRAMAND ELEVATION CITY SPECIFICATION NO.DATE:PROJECT TITLE:SHEET TITLE:ofSHEET NO.33DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSEPTEMBER 2019DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENTS PROJECTTBDE-11129AS NOTED ON PLANSCLEARWELL NO. 2WTP KEY PLAN, CLEARWELL N0. 2PARTIAL ELECTRICAL PLANS (E) SAMPLE SINK(E) UTILITY TABLE(E) FUME HOODCITY SPECIFICATION NO.DATE:PROJECT TITLE:SHEET TITLE:ofSHEET NO.33DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSEPTEMBER 2019DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENTS PROJECTTBDE-11230AS NOTED ON PLANSCLEARWELL N0. 2TRANSFER PUMP STATIONPARTIAL ELECTRICAL PLANS, PANEL LP4C SCHEDULE CITY SPECIFICATION NO.DATE:PROJECT TITLE:SHEET TITLE:ofSHEET NO.33DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSEPTEMBER 2019DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENTS PROJECTTBDE-12031AS NOTED ON PLANSEDNA TANK240/120V & 480VONE LINE DIAGRAMS, PANEL SCHEDULES CITY SPECIFICATION NO.DATE:PROJECT TITLE:SHEET TITLE:ofSHEET NO.33DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSEPTEMBER 2019DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENTS PROJECTTBDE-12132AS NOTED ON PLANSEDNA TANKSITE KEY PLANPARTIAL TANK PLAN CITY SPECIFICATION NO.DATE:PROJECT TITLE:SHEET TITLE:ofSHEET NO.33DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATIONSEPTEMBER 2019DISINFECTION BYPRODUCT REDUCTION AND WATERTREATMENT PLANT PIPE GALLERY IMPROVEMENTS PROJECTTBDE-12233AS NOTED ON PLANSEDNA TANKSERVICE VAULT & SERVICE BUILDINGPARTIAL ELECTRICAL PLANS, MOTOR CONTROL DIAGRAM