HomeMy WebLinkAboutItem 06_P&R Office Rehab_a_COUNCIL READING FILE - 91562 Project Plansa� co ani U �I L m UI U c co `m 0- 0 J U) 0 U 00 U 0 N M a� E U 0 20 r` co M N O U M L 0 a) N U) rnU ABBREVIATIONS ABV ABOVE JST JOIST ACOUS ACOUSTICAL JT JOINT ACT ACOUSTICAL CEILING TILE LAM LAMINATE AD AREA DRAIN LAV LAVATORY ADJ ADJUSTABLE LB(S) POUNDS AFF ABOVE FINISH FLOOR LDG LANDING ALT ALTERNATE LT LIGHT ALUM ALUMINUM MAX MAXIMUM APPROX APPROXIMATE MECH MECHANICAL ARCH ARCHITECT MEMB MEMBRANE B.O. BOTTOM OF MFR MANUFACTURER BALC BALCONY MIN MINIMUM BD BOARD MISC MISCELLANEOUS BET BETWEEN MO MASONRY OPENING BLDG BUILDNG MTD MOUNTED BLKG BLOCKING MTL METAL BLW BELOW N NORTH BM BEAM NIC NOT IN CONTRACT BOT BOTTOM NO NUMBER BRKT BRACKET NOM NOMINAL BULKHD BULKHEAD NTS NOT TO SCALE BUR BUILT UP ROOF O.P. OVERFLOW PIPE C.G. CORNER GUARD OA OVERALL CAB CABINET OC ON CENTER CALK CAULKING OD OUTSIDE DIAMETER CEM CEMENT OFF OFFICE CER CERAMIC OH OPPOSITE HAND CJ CONTROL JOINT OPG OPENING CLG CEILING OPP OPPOSITE CLOS CLOSET PART PARTITION CLR CLEAR PERM PERIMETER CO CASED OPENING PG PAINT GRADE COL COLUMN PLAM PLASTIC LAMINATE CONC CONCRETE PLAS PLASTER CONT CONTINUOUS PLYWD PLYWOOD CPT CARPET PR PAIR CT CERAMIC TILE PT PAINT CTR CENTER PTD PAINTED DBL DOUBLE R RISER DET DETAIL RAD RADIUS DIA DIAMETER RCP REFLECTED CEILING PLAN DIM DIMENSION RD ROOF DRAIN DN DOWN RE REFER DR DOOR REF REFRIGERATOR DS DOWN SPOUT REINF REINFORCED DW DISHWASHER REQD REQUIRED DWG DRAWING RESIL RESILIENT E EAST RM ROOM EA EACH RO ROUGH OPENING EIFS EXTERIOR INSULATION & RTU ROOF TOP UNIT (MECH) FINISH SYSTEM S SOUTH ELEC ELECTRIC SAFB SOUND ATTENUATION FIBER ELEV ELEVATION BATT EMER EMERGENCY SC SCUPPER ENCL ENCLOSURE SCHED SCHEDULE EOS EDGE OF SLAB SEAL SEALANT EQ EQUAL SECT SECTION EQUIP EQUIPMENT SF SQUARE FOOT ETR EXISTING TO REMAIN SHT SHEET EW EACH WAY SIM SIMILAR EXP. JT. EXPANSION JOINT SPEC SPECIFICATION EXST EXISTING SQ SQUIRE F.O. FACE OF SS STAINLESS STEEL FA FIRE ALARM STD STANDARD FAP FIRE ANNUNCIATOR PANEL STL STEEL FD FLOOR DRAIN STOR STORAGE FE FIRE EXTINGUISHER STRUCT STRUCTURAL FEC FIRE EXTINGUISHER PANEL SUSP SUPSPENDED FG FINISH GROUP SYM SYMMMETRICAL FH FIRE HYDRANT T TREAD FHC FIRE HOSE CABINET T&G TONGUE & GROOVE FIN FINISH TEL TELEPHONE FLR FLOOR TER TERRAZZO FLUOR FLOURESCENT THK THICK FT FOOT OR FEET THR THRESHOLD FUR FURRING TO TOP OF GAL GALLON TYP TYPICAL GALV GALVANIZED UC UNDERCUT GB GRAB BAR UNFIN UNFINISHED GC GENERAL CONTRACTOR LINO ULNESS NOTED OTHERWISE GL GLASS LION UNLESS OTHERWISE NOTED GND GROUND UTIL UTILITY GWB GYPSUM BOARD VCT VINYL COMPOSITION TILE GYP GYPSUM VERT VERTICAL H.W.H. HOT WATER HEATER VIF VERIFY IN FIELD HDWD HARDWOOD VTR VENT TERMINATION PIPE HDWR HARDWARE VWC VINYL WALL COVERING HM HOLLOW METAL W WEST HORIZ HORIZONTAL W/ WITH HR HOUR W/O WITHOUT HT HEIGHT WC WATERCLOSET ID INNER DIAMETER WIN WINDOW INCAN INCANDESCENT WP WATERPROOF INSUL INSULATION WS WETSTACK INT INTERIOR WSCT WAINSCOT JAN JANITOR WT WEIGHT SYMBOLS 20 1.01 A /VIEW NUMBER VIEW TITLE View Name 02 1/8" = V-0" SCALE VIEW SHEET LOCATION REFERENCE SHEET LOCATION NORTH ARROW LEVEL DESIGNATION N- 0" BUILDING ELEVATION LEVEL 201 DOOR TAG ELEVATION 01 WINDOW TAG GRID REFERENCE SIM 1 SECTION REFERENCE A101 SIM 1 DETAIL REFERENCE A101 CENTER LINE JREVISION CITY OF SAN LUIS OBISPO PARKS AND RECREATION OFFICE REHABILITATION 1341 NIPOMO STREET SAN LUIS OBISPO, CA 93401 GENERAL NOTES 1. APPLICABLE CODES AND STANDARDS: 1.1. 2016 CALIFORNIA BUILDING CODE AND ITS APPENDICES AND STANDARDS. 1.3. 2016 CALIFORNIA FIRE CODE AND ITS APPENDICES AND STANDARDS. 1.4. 2016 CALIFORNIA ELECTRICAL CODE AND ITS APPENDICES AND STANDARDS. 1.6 2016 CALIFORNIA ENERGY CODE (CENCT T24.6) 1.7 CURRENT CITY OF SAN LUIS OBISPO MUNICIPAL CODE. 2. ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY WITH EXISTING SITE CONDITIONS. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO, HE/SHE SHALL BE PRECEDING AT HIS/HER OWN RISK. 4. DIMENSIONS SHOWN SHALL TAKE PRECEDENCE OVER DRAWING SCALE OR PROPORTION. LARGER SCALE DRAWINGS SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. 5. IN THE EVENT OF THE UNFORESEEN ENCOUNTER OF MATERIALS SUSPECTED TO BE OF AN ARCHAEOLOGICAL OR PALEONTOLOGICAL NATURE, ALL GRADING AND EXCAVATION SHALL CEASE IN THE IMMEDIATE AREA AND THE THE CONTRACTOR SHALL NOTIFY THE OWNER. THE FIND SHALL BE LEFT UNTOUCHED UNTIL AN EVALUATION BY A QUALIFIED ARCHAEOLOGIST OR PALEONTOLOGIST IS MADE. 6. CONTRACTOR IS TO BE RESPONSIBLE FOR BEING FAMILIAR WITH THESE DOCUMENTS INCLUDING ALL CONTRACT REQUIREMENTS. 12. OSHA PERMITS REQUIRED FOR VERTICAL CUTS 5' OR OVER. 15 CONTRACTOR TO REVIEW CALIFORNIA GREEN CODE REQUIREMENTS FOR CONTRACTOR REQUIREMENTS. VICINITY MAP PROJECT DIRECTORY CLIENT: SAN LUIS OBISPO PARKS AND RECREATION DEPARTMENT ADDRESS: 1341 NIPOMO STREET SAN LUIS OBISPO, CA 93401 PHONE (805) 783-7735 FAX: CONTACT SHELSIE KLOEPPER, ENGINEER II EMAIL: SKloepper@slocity.org ARCHITECT: RRM DESIGN GROUP ADDRESS: 3765 S. HIGUERA STREET, SUITE 102 SAN LUIS OBISPO, CA 93401 PHONE (805) 543-1794 FAX: (805) 543-4609 CONTACT PAT BLOTE EMAIL: plblote@rrmdesign.com ELECTRICAL ENGINEER: THOMA ELECTRIC INC. ADDRESS: 3562 EMPLEO STREET, SUITE C SAN LUIS OBISPO, CA 93401 PHONE (805) 543-3850 FAX: (805) 543-3829 CONTACT ROGER PHEHEIM EMAIL: PROJECT DATA ADRESS: 1341 NIPOMO ST SAN LUIS OBISPO, CA 93401 A.P.N 03-515-05 OCCUPANCY: B (EXISTING, NO CHANGE) BUILDING AREA: +/-4,190 SF (NO NEW AREA PROPOSED) SPRINKLERED: YES (NFPA 13) PROJECT SCOPE 1 MINOR REMODEL OF EXISTING OFFICES OF CITY OF SAN LUIS OBISPO PARKS AND RECREATION. 2. NO MODIFICATIONS TO STRUCTURAL ELEMENTS PROPOSED. 3. MINOR DEMOLITION TO INCLUDE: REMOVAL OF LOBBY DESK/ CABINETRY, FLOOR FINISHES IN PROPOSED LOCATIONS, NON-STRUCTURAL PARTITIONS. 4. ALL WORK SHOWN IN THE DRAWINGS AND SPECIFICATIONS. 5. ALL INTERIOR WALLS TO BE PATCHED AND REPAINTED. AGENCIES AND UTILITIES BUILDING DEPARTMENT: CITY OF SAN LUIS OBISPO ADDRESS: 919 PALM STREET SAN LUIS OBISPO, CA 93401 PHONE 805-781-7180 FAX: CONTACT EMAIL: BENCHMARK BASIS OF BEARING city of San luis Obispo NOTICE SHEET INDEX GENERAL 0 G-001 COVER SHEET G-002 CODE ANALYSIS G-003 ACCESSIBILITY DETAILS G-103 DISABLE ACCESS REQ./UNREASONABLE HARDSHIP GENERAL:4 ARCHITECTURAL AS -101 ARCHITECTURAL SITE PLAN A-101 EXISTING/DEMO FLOOR PLAN A-102 PROPOSED FLOOR PLAN A-111 REFLECTED CEILING PLAN A-121 ROOF PLAN A-201 EXTERIOR ELEVATIONS 1-101 FURNITURE PLAN 1-201 INTERIOR ELEVATIONS & DETAILS 1-501 FINISH SCHEDULE & LEGEND ARCHITECTURAL: 9 ELECTRICAL E-001 GENERAL NOTES, LEGEND AND ABBREVIATIONS E-002 SINGLE LINE DIAGRAM AND ELECTRICAL SCHEDULES E-101 ELECTRICAL DEMOLITION PLAN E-102 ELECTRICAL /COMMUNICATIONS FLOOR PLAN E-201 COMMUNICATION RISER DIAGRAM AND DETAILS ELECTRICAL: 5 Grand total: 18 SAN LUIS OBISPO PUBLIC WORKS DATE: APPROVAL BY THE CITY DOES NOT GUARANTEE ACCURACY NOR COMPLETENESS OF THESE PLANS. IT DOES AUTHORIZE THE OWNER TO BUILD THE PROJECT HEREON. IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND ENGINEER OF RECORD TO CORRECT ANY DEFICIENCIES THAT APPEAR DURING OR AFTER CONSTRUCTION. CITY SPECIFICATIONS AND ENGINEERING STANDARDS SHALL BE FOLLOWED UNLESS THE ARE SPECIFICALLY WAIVED OR MODIFIED BY NOTES ON THESE PLANS. THE ENGINEER OF RECORD SHALL PROVIDE SUBMITTALS AS REQUIRED IN THE ENGINEERING STANDARDS. ELECTRIC CO. GAS CO. TELEPHONE CO. TELEVISION CO. DATE 0 REVISIONS DESCRIPTION V) z' DRAWN BY: XX DATE DATE DATE DATE COMMUNITY DEVELOPMENT DIRECTOR: CITY UTILITIES ENGINEER: RECOMMENDED FOR APPROVAL BY: SAN LUIS OBISPO PUBLIC WORKS BY: APPROVAL IMPROVEMENT PLANS FOR: =NGR CITY SLO PARKS AND REC CITY OF SAN LUIS OBISPO, CA CHECKED BY: JOB NO. XX CITY FILE NO. SHEET XX DATE DATE DATE DATE ►"1 N 0 LU V) V) W 0::� 0 0 /� LL design group rrmdesign.com 1 (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RPM DESIGN GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. RRM DESIGN GROUP COPYRIGHT 2017. RRM IS A CALIFORNIA CORPORATION 06 V) he ix 44 L W V_ O z LLM F_W O O W CIO a O '=^ � �/ I O W CIO > W Q Q W U Q U oc vi W Ck O U NO REVISION DATE Z PROJECT MANAGER PB DRAWN BY CHECKED BY EC/SW DATE 09/04/2019 PROJECT NUMBER 1321-01-C 118 SHEET G-001 city of san luis obispo XX XX SLO PARKS AND REC CITY OF SAN LUIS OBISPO, CA XXXX BENCHMARK BASIS OF BEARING SAN LUIS OBISPO PUBLIC WORKS DATE: APPROVAL BY THE CITY DOES NOT GUARANTEE ACCURACY NOR COMPLETENESS OF THESE PLANS. IT DOES AUTHORIZE THE OWNER TO BUILD THE PROJECT HEREON. IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND ENGINEER OF RECORD TO CORRECT ANY DEFICIENCIES THAT APPEAR DURING OR AFTER CONSTRUCTION. CITY SPECIFICATIONS AND ENGINEERING STANDARDS SHALL BE FOLLOWED UNLESS THE ARE SPECIFICALLY WAIVED OR MODIFIED BY NOTES ON THESE PLANS. THE ENGINEER OF RECORD SHALL PROVIDE SUBMITTALS AS REQUIRED IN THE ENGINEERING STANDARDS. NOTICE IMPROVEMENT PLANS FOR:REVISIONS DESCRIPTION CITY FILE NO. SHEETDRAWN BY: CHECKED BY: JOB NO. DATE APPROVAL ENGR CITY COMMUNITY DEVELOPMENT DIRECTOR: CITY UTILITIES ENGINEER: RECOMMENDED FOR APPROVAL BY: SAN LUIS OBISPO PUBLIC WORKS BY: DATE DATE DATE ELECTRIC CO. GAS CO. TELEPHONE CO. TELEVISION CO.DATE WDID# DATE DATE DATE DATE 201 01 A101 1 SIM 1 NORTH ARROW LEVEL DESIGNATION DOOR TAG WINDOW TAG GRID REFERENCE SECTION REFERENCE VIEW SHEET LOCATION REFERENCE SHEET LOCATION VIEW NUMBER SCALE VIEW TITLE LEVEL ELEVATION BUILDING ELEVATION DETAIL REFERENCE CENTER LINE REVISION View Name 1/8" = 1'-0"A-1.01 A-2.02 20 0 Name 0' - 0" A101 1 SIM PROJECT SITE P I S M O S T . B E A C H S T . MA R S H S T . N I P O M O S T . EMERSON PARK P A C I F I C S T . SHEET INDEX ABBREVIATIONS AGENCIES AND UTILITIESPROJECT DIRECTORYGENERAL NOTES ADDRESS: PHONE : FAX: CONTACT :EMAIL: SAN LUIS OBISPO PARKS AND RECREATION DEPARTMENT 1341 NIPOMO STREET SAN LUIS OBISPO, CA 93401 (805) 783-7735 SHELSIE KLOEPPER, ENGINEER II SKloepper@slocity.org CLIENT: ADDRESS: PHONE : FAX: CONTACT :EMAIL: RRM DESIGN GROUP 3765 S. HIGUERA STREET, SUITE 102 SAN LUIS OBISPO, CA 93401 (805) 543-1794 (805) 543-4609 PAT BLOTE plblote@rrmdesign.com ARCHITECT: ADDRESS: PHONE : FAX: CONTACT :EMAIL: THOMA ELECTRIC INC. 3562 EMPLEO STREET, SUITE C SAN LUIS OBISPO, CA 93401 (805) 543-3850 (805) 543-3829 ROGER PHEHEIM ELECTRICAL ENGINEER: VICINITY MAP SYMBOLS PROJECT SCOPE JST JOIST JT JOINT LAM LAMINATE LAV LAVATORY LB(S) POUNDS LDG LANDING LT LIGHT MAX MAXIMUM MECH MECHANICAL MEMB MEMBRANE MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTD MOUNTED MTL METAL NNORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE O.P. OVERFLOW PIPE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OFF OFFICE OH OPPOSITE HAND OPG OPENING OPP OPPOSITE PART PARTITION PERM PERIMETER PG PAINT GRADE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD PR PAIR PT PAINT PTD PAINTED RRISER RAD RADIUS RCP REFLECTED CEILING PLAN RD ROOF DRAIN RE REFER REF REFRIGERATOR REINF REINFORCED REQD REQUIRED RESIL RESILIENT RM ROOM RO ROUGH OPENING RTU ROOF TOP UNIT (MECH) SSOUTH SAFB SOUND ATTENUATION FIBER BATT SC SCUPPER SCHED SCHEDULE SEAL SEALANT SECT SECTION SF SQUARE FOOT SHT SHEET SIM SIMILAR SPEC SPECIFICATION SQ SQURE SS STAINLESS STEEL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUPSPENDED SYM SYMMMETRICAL T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TER TERRAZZO THK THICK THR THRESHOLD TO TOP OF TYP TYPICAL UC UNDERCUT UNFIN UNFINISHED UNO ULNESS NOTED OTHERWISE UON UNLESS OTHERWISE NOTED UTIL UTILITY VCT VINYL COMPOSITION TILE VERT VERTICAL VIF VERIFY IN FIELD VTR VENT TERMINATION PIPE VWC VINYL WALL COVERING WWEST W/ WITH W/O WITHOUT WC WATERCLOSET WIN WINDOW WP WATERPROOF WS WETSTACK WSCT WAINSCOT WT WEIGHT ABV ABOVE ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE AD AREA DRAIN ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATE ARCH ARCHITECT B.O. BOTTOM OF BALC BALCONY BD BOARD BET BETWEEN BLDG BUILDNG BLKG BLOCKING BLW BELOW BM BEAM BOT BOTTOM BRKT BRACKET BULKHD BULKHEAD BUR BUILT UP ROOF C.G. CORNER GUARD CAB CABINET CALK CAULKING CEM CEMENT CER CERAMIC CJ CONTROL JOINT CLG CEILING CLOS CLOSET CLR CLEAR CO CASED OPENING COL COLUMN CONC CONCRETE CONT CONTINUOUS CPT CARPET CT CERAMIC TILE CTR CENTER DBL DOUBLE DET DETAIL DIA DIAMETER DIM DIMENSION DN DOWN DR DOOR DS DOWN SPOUT DW DISHWASHER DWG DRAWING E EAST EA EACH EIFS EXTERIOR INSULATION & FINISH SYSTEM ELEC ELECTRIC ELEV ELEVATION EMER EMERGENCY ENCL ENCLOSURE EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT ETR EXISTING TO REMAIN EW EACH WAY EXP. JT. EXPANSION JOINT EXST EXISTING F.O. FACE OF FA FIRE ALARM FAP FIRE ANNUNCIATOR PANEL FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER PANEL FG FINISH GROUP FH FIRE HYDRANT FHC FIRE HOSE CABINET FIN FINISH FLR FLOOR FLUOR FLOURESCENT FT FOOT OR FEET FUR FURRING GAL GALLON GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GL GLASS GND GROUND GWB GYPSUM BOARD GYP GYPSUM H.W.H. HOT WATER HEATER HDWD HARDWOOD HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT ID INNER DIAMETER INCAN INCANDESCENT INSUL INSULATION INT INTERIOR JAN JANITOR ADDRESS: PHONE : FAX: CONTACT :EMAIL: CITY OF SAN LUIS OBISPO 919 PALM STREET SAN LUIS OBISPO, CA 93401 805-781-7180 BUILDING DEPARTMENT:GENERAL G-001 COVER SHEET G-002 CODE ANALYSIS G-003 ACCESSIBILITY DETAILS G-103 DISABLE ACCESS REQ./UNREASONABLE HARDSHIP GENERAL: 4 ARCHITECTURAL AS-101 ARCHITECTURAL SITE PLAN A-101 EXISTING/DEMO FLOOR PLAN A-102 PROPOSED FLOOR PLAN A-111 REFLECTED CEILING PLAN A-121 ROOF PLAN A-201 EXTERIOR ELEVATIONS I-101 FURNITURE PLAN I-201 INTERIOR ELEVATIONS & DETAILS I-501 FINISH SCHEDULE & LEGEND ARCHITECTURAL: 9 ELECTRICAL E-001 GENERAL NOTES, LEGEND AND ABBREVIATIONS E-002 SINGLE LINE DIAGRAM AND ELECTRICAL SCHEDULES E-101 ELECTRICAL DEMOLITION PLAN E-102 ELECTRICAL /COMMUNICATIONS FLOOR PLAN E-201 COMMUNICATION RISER DIAGRAM AND DETAILS ELECTRICAL: 5 Grand total: 18 1 MINOR REMODEL OF EXISTING OFFICES OF CITY OF SAN LUIS OBISPO PARKS AND RECREATION. 2. NO MODIFICATIONS TO STRUCTURAL ELEMENTS PROPOSED. 3. MINOR DEMOLITION TO INCLUDE: REMOVAL OF LOBBY DESK/ CABINETRY, FLOOR FINISHES IN PROPOSED LOCATIONS, NON-STRUCTURAL PARTITIONS. 4. ALL WORK SHOWN IN THE DRAWINGS AND SPECIFICATIONS. 5. ALL INTERIOR WALLS TO BE PATCHED AND REPAINTED. CITY OF SAN LUIS OBISPO PARKS AND RECREATION OFFICE REHABILITATION 1341 NIPOMO STREET SAN LUIS OBISPO, CA 93401 1. APPLICABLE CODES AND STANDARDS: 1.1. 2016 CALIFORNIA BUILDING CODE AND ITS APPENDICES AND STANDARDS. 1.3. 2016 CALIFORNIA FIRE CODE AND ITS APPENDICES AND STANDARDS. 1.4. 2016 CALIFORNIA ELECTRICAL CODE AND ITS APPENDICES AND STANDARDS. 1.6 2016 CALIFORNIA ENERGY CODE (CENCT T24.6) 1.7 CURRENT CITY OF SAN LUIS OBISPO MUNICIPAL CODE. 2. ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY WITH EXISTING SITE CONDITIONS. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ARCHITECT’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO, HE/SHE SHALL BE PRECEDING AT HIS/HER OWN RISK. 4. DIMENSIONS SHOWN SHALL TAKE PRECEDENCE OVER DRAWING SCALE OR PROPORTION. LARGER SCALE DRAWINGS SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. 5. IN THE EVENT OF THE UNFORESEEN ENCOUNTER OF MATERIALS SUSPECTED TO BE OF AN ARCHAEOLOGICAL OR PALEONTOLOGICAL NATURE, ALL GRADING AND EXCAVATION SHALL CEASE IN THE IMMEDIATE AREA AND THE THE CONTRACTOR SHALL NOTIFY THE OWNER. THE FIND SHALL BE LEFT UNTOUCHED UNTIL AN EVALUATION BY A QUALIFIED ARCHAEOLOGIST OR PALEONTOLOGIST IS MADE. 6. CONTRACTOR IS TO BE RESPONSIBLE FOR BEING FAMILIAR WITH THESE DOCUMENTS INCLUDING ALL CONTRACT REQUIREMENTS. 12. OSHA PERMITS REQUIRED FOR VERTICAL CUTS 5' OR OVER. 15 CONTRACTOR TO REVIEW CALIFORNIA GREEN CODE REQUIREMENTS FOR CONTRACTOR REQUIREMENTS. NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 4 7 A M CO V E R S H E E T CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 G-001 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 PROJECT DATA ADRESS: 1341 NIPOMO ST SAN LUIS OBISPO, CA 93401 A.P.N 03-515-05 OCCUPANCY: B (EXISTING, NO CHANGE) BUILDING AREA: +/-4,190 SF (NO NEW AREA PROPOSED) SPRINKLERED: YES (NFPA 13) EXIT EXIT (E) Open Office 109 (E) Supervisor Office 107 Small Conference Room 106 (E) Supervisor Office 105 (E) Director Office 104 (E) Mech. Room 119 (E) Electrical Room 120 Copy/File/PC Room 117 (E) Break Room 111 (E) Vestibule 112 (E) Janitor Closet 113 (E) Men's Restroom 114 (E) Women's Restroom 115 (E) Shower Room 116 (E) Staff Conference Room 103 (E) Open Office 108 Reception 102 Lobby 101 (E) Storage 118 Enclosed Patio 110 (45)(44)ROOF ABOVE ROOF ABOVE MAX TRAVEL DISTANCE = 72'-0" OCCUPANCY CLASSIFICATION EXISTING AREA (NO MODIFICATIONS) OCCUPANCY: B (EXISTING) OCCUPANT EGRESS PATH OF TRAVEL TO PUBLIC WAY (FOR COMPLETE PATH OF TRAVEL TO PUBLIC WAY REFER TO SHEET AS-101 NUMBER OF OCCUPANTS EXITING SPACE (XX) NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 4 9 A M CO D E A N A L Y S I S CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 G-002 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 CODE ANALYSIS CODE INTERPRETATION OCCUPANCY B OCCUPANCY (EXISTING) 309.1 CONSTRUCTION TYPE VB (EXISTING) T-601 ALLOWABLE BUILDING HEIGHT 40' T-504.3 ALLOWABLE BUILDING AREA 9,000 SF T-503 ALLOWABLE NUMBER OF STORIES 2 STORIES T-503 FIRE SPRINKER INCREASE NOT TAKEN 504.2 FIRE SPRINKLER AREA INCREASE NOT TAKEN 506.3 FIRE RESISTANCE RATING NONE T-601 ONE EGRESS FROM SPACE REQUIRED 49 OCCUPANTS T-1006.2.1 MINIMUM NUMBER OF EXITS 1 MIN. T-1019.2 PROPOSED PROJECT BUILDING AREA 4,190 SF (EXISTING) BUILDING HEIGHT 26'-6" (EXISTING) NUMBER OF STORIES ONE STORY AUTOMATIC FIRE SPRINKLERS NFPA 13 (EXISTING) NO. NAME AREA OCCUPANCY CLASSIFCATION FUNCTION OF SPACE FROM CBC TABLE 1004.1.1 LOAD FACTOR LOAD MAXIMUM OCCUPANT LOAD FOR ONE EXIT FROM CBC TABLE 1015.1 NUMBER OF EXITS 101 Lobby 281 SF B BUSINESS AREAS 100 3 49 1 102 Reception 119 SF B BUSINESS AREAS 100 2 49 1 103 (E) Staff Conference Room 269 SF B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 18 49 1 103 (E) Staff Conference Room Not Placed (none) (none) 104 (E) Director Office 167 SF B BUSINESS AREAS 100 2 49 1 104 (E) Director Office Not Placed (none) (none) 105 (E) Supervisor Office 132 SF B BUSINESS AREAS 100 2 49 1 105 (E) Supervisor Office Not Placed (none) (none) 106 Small Conference Room 133 SF B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 9 49 1 107 (E) Supervisor Office 133 SF B BUSINESS AREAS 100 2 49 1 107 (E) Supervisor Office Not Placed (none) (none) 108 (E) Open Office 451 SF B BUSINESS AREAS 100 5 49 1 109 (E) Open Office 1092 SF B BUSINESS AREAS 100 11 49 1 110 Enclosed Patio 168 SF B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 12 49 1 111 (E) Break Room 133 SF B ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED (TABLE AND CHAIRS) 15 9 49 1 111 (E) Break Room Not Placed (none) (none) 112 (E) Vestibule 85 SF B BUSINESS AREAS 100 1 49 1 113 (E) Janitor Closet 45 SF B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 49 1 113 (E) Janitor Closet Not Placed (none) (none) 114 (E) Men's Restroom 107 SF B BUSINESS AREAS 100 2 49 1 114 (E) Men's Restroom Not Placed (none) (none) 115 (E) Women's Restroom 113 SF B BUSINESS AREAS 100 2 49 1 115 (E) Women's Restroom Not Placed (none) (none) 116 (E) Shower Room 46 SF B BUSINESS AREAS 100 1 49 1 116 (E) Shower Room Not Placed (none) (none) 117 Copy/File/PC Room 213 SF B BUSINESS AREAS 100 3 49 1 118 (E) Storage 154 SF B BUSINESS AREAS 100 2 49 1 119 (E) Mech. Room 31 SF B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 49 1 120 (E) Electrical Room 71 SF B ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 1 49 1 Grand total: 29 89 GROUND FLOOR OCCUPANCY LEGEND 1/8" = 1'-0"A-102 G-002 CODE ANALYSIS FLOOR PLAN1 NOTE: NO PROPOSED CHANGES TO OCCUPANCY, BUILDING AREA OR MODIFICATIONS TO FIRE ALARM SYSTEM. CODE ANALYSIS IS SHOWN FOR REFERENCE ONLY. KICK PLATE NOTE: SWINGING DOOR & GATE SURFACES WITHIN 10" OF FINISH FLOOR SHALL HAVE A SMOOTH SURFACE OF THE PUSH SIDE EXTENDING THE FULL WIDTH OF DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS SHALL BE WITHIN 1/16" OF SURFACE & SHALL BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY KICK PLATES SHALL BE CAPPED. F.F. MI N . 0' - 1 0 " REF 11B-404.2.10 DOOR CLOSERS IF PRESENT, MUST BE SET SO THAT IT TAKES DOOR AT LEAST 5 SECONDS TO CLOSE FROM AN OPEN POSITION OF 90 DEGREES TO WITHIN 12° OF LATCH DOOR CLOSERS ACCEPTABLE DOOR HARDWARE AND MOUNTING HEIGHTS PANIC LOOP LEVER 34 " - 4 4 " A . F . F . 12.0 0° REF 11B-404.2 THE FORCE TO OPEN DOOR SHALL NOT EXCEED 5 LBS. TYPICAL. SYMBOL PROPORTIONS DISPLAY CONDITIONS REF 11B-703.7.2.1 12" MIN. 36" MIN. CLR. 60 " M I N . C L R . 44 " M I N . C L R . 54" MIN. CLR. 24" MIN. 60 " M I N . C L R . 44 " M I N . C L R . PUSH SIDE FRONT APPROACH PULL SIDE PUSH SIDE PULL SIDE PUSH SIDE HINGE APPROACH INDICATES CLEARANCE AT DOORS 24" MIN. CLEARPULL SIDE 60 " M I N . C L R . LATCH APPROACH AT INTERIOR DOORS 18" MIN. CLEAR PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER 48 " M I N . C L R . 48" MIN. CLR. IF DOOR HAS BOTH A LATCH AND A CLOSER NOTE: ALL DOORS IN ALCOVES SHLAL COMPLY WITH THE CLEARANCES FOR FRONT APPROACHES 48" MIN. CLR. IF DOOR HAS BOTH A LATCH AND A CLOSER REF 11B-404.2.4 24" MIN. H) J,K) F,G) D) B,C) A) AT EXTERIOR SIDE OF EXTERIOR DOORS 22" MIN. AT EVERY PRIMARY PUBLIC ENTRANCE AND AT EVERY MAJOR JUNCTION WHERE THE ACCESSIBLE ROUTE OF TRAVEL DIVERGES FROM THE REGULAR CIRCULATION PATH ALONG OR LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL, ENTRANCE, OR FACILITY, THERE SHALL BE A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. INTERNATIONAL SYMBOL OF ACCESSIBILITY. 60 " @ 1:2 SLOPE 1/4" - 1/2" MAX. 0' - 0 1/4" BEVEL ED. INTERIOR MAT CARPETING MUST CONSIST OF: -LEVEL LOOP -TEXTURED LOOP -LEVEL CUT PILE, OR -LEVEL CUT/UNCUT PILEIF PILE HEIGHT EXCEEDS 1/4", THEN EDGES MUST HAVE BEVELED TRIM REF. 11B 303 VERTICAL CARPET PILE HEIGHT 0' - 0 1/2" MAX. REF. 11B 302.2 .0'-1/4" MAX 0' - 0 1/4" MAX. 1 2 6"6" 1' - 0" 3' - 0" 6" 12" DIA. CONCRETE FOOTING 2"X2" POST PER PLAN, EMBED IN CONCRETE ADJACENT SURFACE- REFER TO CIVIL DRAWINGSLOPESLOPE.. MINIMUM FINE $250 VAN ACCESSIBLE MINIMUM FINE $250 1/2" RADIUS, TYP. BLUE WHITE REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL W/ BEADED TEXT OR EQUAL, TYP. 60" MIN. FOR WALL MOUNTED 80" MIN. IF LOCATED IN ACCESSIBLE ROUTE T.O. WALKING SURFACE NOTE: 1. SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE. 2. AREA OF SIGN TO BE A MIN. OF 70 SQ. INCHES 3. VAN ACCESSIBLE PARKING SPACES SHALL HAVE AN ADDITIONAL SIGN OR LANGUAGE STATING "VAN ACCESSIBLE" MOUNTED BELOW THE SYMBOL OF ACCESSIBILITY. 4. AN ADDITIONAL SIGN OR LANGUAGE BELOW THE SYMBOL OF ACCESSIBILITY SHALL STATE "MINIMUM FINE $250". 5. DO NOT PLACE PARKING SIGNAGE IN 2'-0" CLEAR VEHICLE OVERHANG ZONE REF 1109A.8.8 "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT________ OR BY TELEPHONING _______." BLANK SPACES ARE TO BE FILLED IN WITH APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN. T.O. WALKING SURFACE UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT _________ OR BY TELEPHONING _______. 60" MIN. FOR WALL MOUNTED 80" MIN. IF LOCATED IN ACCESSIBLE ROUTE NOTE: 1. SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE. 2. THE SIGN SHALL NOT BE LESS THAN 17 INCHES BY 22 INCHES IN SIZE WITH 1 INCH HIGH MINIMUM LETTERING WHICH CLEARLY AND CONSPICUOSLY STATES THE FOLLOWING: 1/2" RADIUS, TYP. BLUE WHITE REFLECTED SIGN CONSTRUCTED OF PORCELAIN STEEL W/ BEADED TEXT OR EQUAL, TYP. 1" MIN. HIGH LETTERING NOTE: RECLAIMING INFORMATION AND ASSOCIATED TELEPHONE NUMBER IS TO BE IN PLACE AT TIME OF FINAL INSPECTION (TBD BY OWNER) REF 1109A.8.8 NO PARKING Van Stall 12' - 0" Access Aisle 5' - 0" Standard Stall 9' - 0" 18' - 0" Min. White Lettering, 12 inches min. height 4" White Stripes @ 36" o.c. Max, diagonal 3' - 0" 3' - 0" International Symbol of Accessibility complying w CBC 11B-703.7.2.1 (White on Blue or Contrasting Background) EQ EQ Within 6" of Centerline & Aligned at End of Stall Blue Border Identification Sign6" Conc. curb or 4" Blue Stripe 6" Curb (M a x.)3 6" Wheel Stop 2% M A X S L O P E 2% M A X S L O P E 2% MAX SLOPE NOTE: PARKING MUST COMPLY WITH CALTRANS STANDARD PLANS A24C & A90A 2' - 0" 0.18" - 0.22" TOP DIAMETER 0.45" - 0.47" BASE DIAMETER 0.9" - 0.92" 2.3" - 2.4" 2.3" - 2.4" 0.65" MIN. REF 11B-705.1PLAN ENLARGED ELEVATION D150700-005 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C:\Users\ecervantes\Documents\1321-01-CI18 City of SLO Parks and Rec_Central_ecervantes.rvt 9/4/2019 10:23:50 AM AC C E S S I B I L I T Y D E T A I L S CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 G-003 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 1" = 1'-0"G-003 KICK PLATE AT DOORS12 1" = 1'-0"G-003 ACC. DOOR REQUIREMENTS11 3" = 1'-0"G-003 INTL SYMBOL OF ACC.8 1/2" = 1'-0"G-003 CLEARANCES AT DOORS & GATES23 3" = 1'-0"G-003 ACC. BLDG. ENTRY SIGNAGE13 12" = 1'-0"G-003 CHANGES IN LEVEL14 1" = 1'-0"G-003 SIGN POST FOOTING42 3/4" = 1'-0"G-003 ACC. PARKING STALL SIGN41 3/4" = 1'-0"G-003 TOWING SIGNAGE51 3/16" = 1'-0"AS-101G-003 ACC. PARKING STALL43 3" = 1'-0"G-003 ACC. DETECTABLE TEXTURE44 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C:\Users\ecervantes\Documents\1321-01-CI18 City of SLO Parks and Rec_Central_ecervantes.rvt 9/4/2019 10:24:06 AM DI S A B L E A C C E S S RE Q . / U N R E A S O N A B L E H A R D S H I P CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 G-103 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 NOTE: THE FOLLOWING LIST(CREATED BY DISABLITY ACCESS CONSULTANTS) ARE THE SUGGESTED UPGRADES/ALTERATIONS THAT SATISFIES THE 20% OF THE ADJUSTED CONSTRUCTION COST OF ALTERATIOS, STRUCTURAL REPAIRS AND ADDITIONS. GRAND TOTAL FOR SUGGESTED UPGRADES= 30,269 (MIN. 20% OF CONSTRUCTION COST=30,000), UP EXISTING BUILDING EXISTING TRASH ENCLOSURE NIPOMO ST PA C I F I C S T R E E T EXISTING PARKING EXISTING PARKING EXIT ONLYENTRANCE ONLY RESTRIPE ADA PARKING G-003 43 PATH OF TRAVEL EXISTING BUILDING EXISTING PATHWAYS GENERAL NOTES LEGEND 1/16" = 1'-0"A-102 AS-101 ARCHITECTURAL SITE PLAN1 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 4 3 A M AR C H I T E C T U R A L S I T E P L A N CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 AS-101 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 1 FOR DISABLE ACCESS UPGRADES REGARDING UNREASONABLE HARDSHIP REFER TO SHEET G-103. REFER TO SHEET G-003 FOR ACCESSIBILITY DETAILS. 2 ALL ADA PATH OF TRAVEL ARE EXISTING, ACCESSIBILITY COMPLIANCE TO BE CHECKED IN FIELD. 1 22 33 44 55 66 77 88 99 11 10 12 5' - 9 " 11 ' - 9 " 11 ' - 0 " 11 ' - 0 " 11 ' - 0 " 11 ' - 0 " 11 ' - 0 " 14 ' - 3 " 13 14 6' - 0" 1 1' - 3" 1 1' - 3" 6' - 3" G A B C D E F 12' - 3"3' - 6"8' - 9"12' - 3"12' - 3" 49' - 0" H I J K 6' - 0" 11 ' - 3 " 11 ' - 3 " 6' - 3" 16 ' - 9 " 86 ' - 9 " 14 ' - 6 " 35 ' - 0 " 3 4' - 9" 34 ' - 9 " 156 102 102 152 152 152 152 163 163 163 153 (E) Open Office 109 (E) Supervisor Office 107 Small Conference Room 106 (E) Supervisor Office 105 (E) Director Office 104 (E) Mech. Room 119 (E) Electrical Room 120 Copy/File/PC Room 117 (E) Break Room 111 (E) Vestibule 112 (E) Janitor Closet 113 (E) Men's Restroom 114 (E) Women's Restroom 115 (E) Shower Room 116 (E) Staff Conference Room 103 (E) Open Office 108 Reception 102 Lobby 101 (E) Storage 118 105 106 107 107 NOT IN SCOPE NOT IN SCOPE 163 163 163 101103 120 NOT IN SCOPE; NO MODIFICATIONS PROPOSED EXISTING FLOOR TO BE REMOVED EXISTING WALL TO BE REMOVED NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 2 7 A M EX I S T I N G / D E M O F L O O R P L A N CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 A-101 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 1/8" = 1'-0"A-102 A-101 EXISTING/DEMO GROUND FLOOR PLAN1 GENERAL NOTES KEYNOTES LEGEND 1. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 2. ALL FURNITURE AND EQUIPMENT IS TO BE PURCHASED AND INSTALLED BY CONTRACTOR. 3. REFER TO FINISH PLAN AND SCHEDULE FOR INTERIOR WALL, CEILING AND FLOOR FINSH INFORMATION. 4. DIMENSIONS ARE TO FACE OF FRAMING UNLESS SPECIFICALLY NOTED OTHERWISE. 5. PROVIDE FIRE BLOCKING FOR WALL CAVITIES THAT EXCEED CBC HEIGHT LIMITATION. 6. REMOVE EXISTING FLOORING IN SCOPE, REPLACE PER FINISH PLAN. 7. REFER TO I-501 FOR FINISH SCHEDULE AND LEGEND. 8. FURNITURE PROVIDER TO PERFORM SITE VISIT TO CONFIRM DIMENSIONS PRIOR TO PURCHASING. 101 EXISTING POST TO REMAIN AND BE PROTECTED IN PLACE 102 EXISTING COMMERCIAL STOREFRONT SYSTEM 103 BIKE RACK TO BE RELOCATED 105 EXISTING RECEPTION DESK TO BE REMOVED 106 EXISTING HALF DOOR TO BE REMOVED 107 WALL TO BE REMOVED 120 REMOVE AND REPLACE DRINKING FOUNTAIN WITH CITY APPROVED BOTTLE FILLER 152 EXISTING FLOOR FINISH TO BE REMOVED 153 EXISTING CABINET TO REMAIN 156 EXISTING DOOR TO BE REMOVED AND REPLACED WITH WINDOW TO MATCH EXISTING STOREFRONT SYSTEM 163 EXISTING CABINETRY TO BE REMOVED REF. 2 A-201 1 A-201 1 22 33 44 55 66 77 88 99 11 10 12 13 14 G A B C D E F H I J K 5' - 9 " 11 ' - 9 " 11 ' - 0 " 11 ' - 0 " 11 ' - 0 " 11 ' - 0 " 11 ' - 0 " 14 ' - 3 " 6' - 0" 1 1' - 3" 1 1' - 3" 6' - 3" 12' - 3"3' - 6"8' - 9"12' - 3"12' - 3" 49' - 0" 6' - 0" 11 ' - 3 " 11 ' - 3 " 6' - 3" (E) Open Office 109 (E) Supervisor Office 107 Small Conference Room 106 (E) Supervisor Office 105 (E) Director Office 104 (E) Mech. Room 119 (E) Electrical Room 120 Copy/File/PC Room 117 (E) Break Room 111 (E) Vestibule 112 (E) Janitor Closet 113 (E) Men's Restroom 114 (E) Women's Restroom 115 (E) Shower Room 116 (E) Staff Conference Room 103 (E) Open Office 108 Reception 102 Lobby 101 86 ' - 9 " 4' - 0"7' - 6" (E) Storage 118 108 A-102 2 B Enclosed Patio 110 5 FOOT HIGH WALL V.I.F 5'-0" MIN. 5' - 2" 5 FOOT HIGH WALL 411 I-201 4 I-201 8 EXISTING WALLS TO REMAIN. INTERIOR- WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE. STUD SIZE TO BE VERIFIED IN FIELD TO BE FLUSH ON BOTH SIDES WITH ADJACENT WALL. NOT IN SCOPE. INTERIOR- 3 1/2" WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE. B A 6 F 101 123 Enclosed Patio 110 A-102414 ' - 6 " 3' - 7" 121 88 99 11 12 13 C D E I 14 ' - 3 " 1 1' - 3" 1 1' - 3" 3' - 6"8' - 9" (E) Staff Conference Room 103 Reception 102 Lobby 101 MIN. 3' - 0" MIN. 3' - 0" B BA 6' H RECEPTION DESK TO COMPLY WITH SECTION 11B-904.4 OF THE CBC30x48 Clr (E) SECTION OF STOREFRONT TO RECEIVE GLASS PANEL I-201 8 01-GROUND FLOOR 0' -0" 03-ROOF 9' -3" 6 EXISTING POST 6' - 0" GATE 121 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 2 9 A M PR O P O S E D F L O O R P L A N CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 A-102 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 1/8" = 1'-0"A-102 A-102 PROPOSED FLOOR PLAN1 LEGEND 1. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 2. ALL FURNITURE AND EQUIPMENT IS TO BE PURCHASED AND INSTALLED BY CONTRACTOR. 3. REFER TO FINISH PLAN AND SCHEDULE FOR INTERIOR WALL, CEILING AND FLOOR FINSH INFORMATION. 4. DIMENSIONS ARE TO FACE OF FRAMING UNLESS SPECIFICALLY NOTED OTHERWISE. 5. PROVIDE FIRE BLOCKING FOR WALL CAVITIES THAT EXCEED CBC HEIGHT LIMITATION. 6. REMOVE EXISTING FLOORING IN SCOPE, REPLACE PER FINISH PLAN. 7. REFER TO I-501 FOR FINISH SCHEDULE AND LEGEND. 8. FURNITURE PROVIDER TO PERFORM SITE VISIT TO CONFIRM DIMENSIONS PRIOR TO PURCHASING. GENERAL NOTES KEYNOTES 101 EXISTING POST TO REMAIN AND BE PROTECTED IN PLACE 108 NEW REFRIGERATOR, NO ICE-MAKER 121 SURFACE OF FENCE AND GATE ENCLOSURE WILL BE A PLACEHOLDER FOR FUTURE PUBLIC ART (N.I.C) TO BE PROVIDED BY CITY REPRESENTATIVES 123 CITY APPROVED BIKE RACK 411 COPIER WITH STORAGE ABOVE 1/4" = 1'-0"A-102 A-102 ENCLOSED PATIO PLAN2 1/4" = 1'-0"A-102 A-102 ENLARGED LOBBY PLAN3 1/4" = 1'-0"A-102 A-102 ENCLOSED PATIO FENCE4 CEILING HEIGHT10'-0" LIGHT FIXTURE, REFER TO ELECTRICAL PLANS NOT IN SCOPE. 1 22 33 44 55 66 77 88 99 11 10 12 13 14 G A B C D E F H I J K 8' - 0"8' - 0" 8' - 0" 9' - 0" 10' - 0" 9' - 0"9' - 0" 8' - 0" 9' - 0"9' - 0" 8' - 0" 9' - 0" 10' - 0" 10' - 0" 8' - 0"9' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 8" / 1'-0" 8" / 1'-0" 8" / 1'-0" 8" / 1 ' - 0 " 8" / 1'-0" 8 3/4" / 1'-0" 124 124 124 125 125 125 125 125 (E) Director Office 104 Reception 102 Lobby 101 (E) Staff Conference Room 103 (E) Women's Restroom 115 (E) Men's Restroom 114 (E) Open Office 108 Small Conference Room 106 (E) Supervisor Office 105 (E) Supervisor Office 107 (E) Open Office 109 Copy/File/PC Room 117 (E) Storage 118 (E) Electrical Room 120 (E) Mech. Room 119 Enclosed Patio 110 (E) Vestibule 112 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 3 1 A M RE F L E C T E D C E I L I N G P L A N CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 A-111 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 GENERAL NOTES KEYNOTES LEGEND 1. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 2. NO PROPOSED CHANGES TO MECHANICAL SYSTEMS. 3 CEILING TO BE PATCHED WHERE WALLS ARE BEING REMOVED. 124 EXISTING DORMER RIDGE LINE 125 EXISTING BEAMS 1/8" = 1'-0"A-102 A-111 GROUND FLOOR RCP1 1 22 33 44 55 66 77 88 99 11 10 12 13 14 G A B C D E F H I J K NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 3 2 A M RO O F P L A N CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 A-121 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 1/8" = 1'-0"A-102 A-121 ROOF PLAN1 GENERAL NOTES 1. NO PROPOSED CHANGES TO ROOF. 2. ROOF PLAN IS SHOWN FOR REFERENCE ONLY. 01-GROUND FLOOR 0' -0" 03-ROOF 9' -3" 04-T.O. ROOF 27' -0" ABCDEF 01-GROUND FLOOR 0' -0" 03-ROOF 9' -3" 04-T.O. ROOF 27' -0" 1 2 3 4 5 6 7 8 9 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C: \ U s e r s \ e c e r v a n t e s \ D o c u m e n t s \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c _ C e n t r a l _ e c e r v a n t e s . r v t 9/ 4 / 2 0 1 9 1 0 : 2 3 : 3 6 A M EX T E R I O R E L E V A T I O N S CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 A-201 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 GENERAL NOTES 1/8" = 1'-0"A-102 A-201 NORTH ELEVATION1 1/8" = 1'-0"A-102 A-201 EAST ELEVATION2 1. NO PROPOSED CHANGES TO EXTERIOR ELEVATIONS. 2. EXTERIOR ELEVATIONS SHOWN FOR REFERENCE ONLY. REF. 1 22 33 44 55 66 77 88 99 11 10 12 13 14 G A B C D E F H I J K 5' - 9" 11' - 9" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 14' - 3" 6' - 0" 1 1' - 3" 1 1' - 3" 6' - 3" 12' - 3"3' - 6"8' - 9"12' - 3"12' - 3" 49' - 0" 6' - 0" 11 ' - 3 " 11 ' - 3 " 6' - 3" 16' - 9" 7' - 3" (E) Open Office 109 (E) Supervisor Office 107 Small Conference Room 106 (E) Supervisor Office 105 (E) Director Office 104 (E) Mech. Room 119 (E) Electrical Room 120 (E) Break Room 111 (E) Vestibule 112 (E) Janitor Closet 113 (E) Men's Restroom 114 (E) Women's Restroom 115 (E) Shower Room 116 (E) Staff Conference Room 103 Reception 102 Lobby 101 86' - 9" 14' - 6" 35' - 0" Copy/File/PC Room 117 9'X6' CUBICLE 9'X6' CUBICLE 9'X6' CUBICLE 9'X6' CUBICLE 9'X6' CUBICLE PHONE BOOTH 60" x 30" WORKSTATION 72" x 30" WORKSTATION 60" x 30" WORKSTATION EXISTING STORAGE SHELVES 48" x 24" WORKSTATIONS 8'x6' CUBICLE 8'x6' CUBICLE 60" x 24" WORKSTATIONS I-201 1 Sim I-201 2 48" x 24" WORKSTATIONS 60" DIA. TABLE LOCKERS & CHARGING STATION 3' H LATERAL FILES W/ COUNTER 3' H LATERAL FILES W/ COUNTER 3' H LATERAL FILES W/ COUNTER 48" x 24" WORKSTATIONS COPIER W/ STORAGE ABOVE UPPER CABINET TO REMAIN; CABINET DOORS TO BE REFINSIHED. I-201 4 3' - 0" (E) Open Office 109 (E) Supervisor Office 107 Small Conference Room 106 (E) Supervisor Office 105 (E) Director Office 104 (E) Mech. Room 119 (E) Electrical Room 120 Copy/File/PC Room 117 (E) Break Room 111 (E) Vestibule 112 (E) Janitor Closet 113 (E) Men's Restroom 114 (E) Women's Restroom 115 (E) Shower Room 116 (E) Staff Conference Room 103 (E) Open Office 108 Reception 102 Lobby 101 (E) Storage 118 Enclosed Patio 110 I-201 2 I-201 4 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C:\Users\ecervantes\Documents\1321-01-CI18 City of SLO Parks and Rec_Central_ecervantes.rvt 9/4/2019 10:24:10 AM FU R N I T U R E P L A N CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 I-101 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 1. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION. 2. ALL FURNITURE AND EQUIPMENT IS TO BE PURCHASED AND INSTALLED BY CONTRACTOR. 3. REFER TO FINISH PLAN AND SCHEDULE FOR INTERIOR WALL, CEILING AND FLOOR FINSH INFORMATION. 4. DIMENSIONS ARE TO FACE OF FRAMING UNLESS SPECIFICALLY NOTED OTHERWISE. 5. PROVIDE FIRE BLOCKING FOR WALL CAVITIES THAT EXCEED CBC HEIGHT LIMITATION. 6. REMOVE EXISTING FLOORING IN SCOPE, REPLACE PER FINISH PLAN. 7. REFER TO I-501 FOR FINISH SCHEDULE AND LEGEND. 8. FURNITURE PROVIDER TO PERFORM SITE VISIT TO CONFIRM DIMENSIONS PRIOR TO PURCHASING. GENERAL NOTES 1/8" = 1'-0"A-102 I-101 FURNITURE PLAN1 1/8" = 1'-0"A-102 I-101 GROUND FLOOR FINISH PLAN2 01-GROUND FLOOR 0' -0" E IT EXISTING CABINETRY TO REMAIN; REFINISH CABINET DOORS PT-01 PL-01 PL-02 NEW REFRIGERATOR TO BE PROVIDED BY CONTRACTOR. I-201 3 2' - 3" 2' - 7" 1' - 8" 5' - 8" 1 3 5 .0 0 °135.00° 7' - 1" 3' - 8" 2' - 10" 6 I-201 1' - 0" SUPPORT PANELS I-201 8 5' - 7" 3' - 1" 5 I-201 Sim COMPUTER LOCATION; PROVIDE INTERNET AND ELECTRICAL ACCESS 01-GROUND FLOOR 0' -0"PL-02PL-02PL-02 SS-01 WC-01 PT-01PT-01PT-01 PT-01PT-01 RB-01 SS-01 SS-01 SS-01 SS-01 RB-01 01-GROUND FLOOR 0' -0" 1' - 1" 2' - 5" 3' - 6" OPEN BELOW SS-01 SS-01 PL-02 1/2 PLYWOOD SUPPORT I-201 7 1' - 0" 1' - 9" RB-01 01-GROUND FLOOR 0' -0" E A.F.F. 4' - 6" PT-01 PL-02 RB-01 WALL MOUNT = COUNTERTOP DEPTH - 1/2" SURFACE MOUNT = COUNTERTOP DEPTH - 4" HORIZONTAL LEG 5/8" 1' - 8" 4" 7" 7" 2" 2" (3) 1/4" HOLES TYP. L 2"X3"X1/4" FULL PENETRATION WELD, MITER CUT JOINT (3) 1/2" HOLES TYP. FOR SURFACE FACE OF STUD NOTE: GROUND ALL EDGES TO BE SMOOTH AND ROUND WALL FRAMING, RE: FLOOR PLANS 01-GROUND FLOOR 0' -0" OPEN BELOW (3) BUILT-IN DRAWERS; CENTER HANDELS ON EACH DRAWER. HANDLE OPTIONS TO BE SUBMITTED TO ARCHITECT FOR REVIEW & FINAL SELECTION SS-01 PL-02 27" 24"18" 231 PL-02 01-GROUND FLOOR 0' -0" 1' - 1" 2' - 5" 3' - 6" SS-01 FURNITURE PER PLAN. WC-01 1/2 PLYWOOD SUPPORT 1' - 0" RB-01 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C:\Users\ecervantes\Documents\1321-01-CI18 City of SLO Parks and Rec_Central_ecervantes.rvt 9/4/2019 10:24:12 AM IN T E R I O R E L E V A T I O N S & D E T A I L S CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 I-201 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 1/4" = 1'-0"I-101 I-201 COPY ROOM2 1/2" = 1'-0"A-102 I-201 RECEPTION DESK1 1/4" = 1'-0"I-201 I-201 RECEPTION ELEVATION3 1/2" = 1'-0"I-201 I-201 RECEPTION DESK - TRANSACTION SECTION6 1/4" = 1'-0"A-102 I-201 STORAGE ELEVATION4 1 1/2" = 1'-0"I-201 I-201 BRACKET SUPPORT7 1/2" = 1'-0"A-102 I-201 RECEPTION DESK - CABINET8 1/2" = 1'-0"I-201 I-201 RECEPTION- TRANSACTION SECTION5 GENERAL NOTES 1. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION ON ELECTRICAL EQUIPMENT, LIGHTING FIXTURES AND LOCATIONS OF ELECTRICAL OUTLETS. CONTRACTOR TO PROVIDE GROMMETS AT ALL COUNTERTOPS AND LOCATE ABOVE THE ELECTRICAL DEVICES 2. CONTRACTOR TO REFER TO DETAILS FOR CABINET BLOCKING. 3. REFER TO REFLECTED CEILING PLANS FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION. 4. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND FIXTURES OCCUR. 6. ALL DIMENSIONS SHOWN IN A ROOM ARE TO BE CONSIDERED TYPICAL FOR EACH ELEVATION OF THE ROOM, UNLESS OTHERWISE NOTED 10. REFER TO ACCESSIBILITY DETAILS FOR ACCESSIBILITY REQUIREMENTS AT PUBLIC RESTROOM. 11. PROVIDE 1" MIN. SCRIBE TRIM WHERE CABINETRY ABUTS WALLS OR CEILINGS/SOFFITS, TYP. U.N.O. NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEETNOT FOR CONSTRUCTIONrrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017.RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGNGROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS ORUSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIEDPROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THEWRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGSOR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESERESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEWSHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. C:\Users\ecervantes\Documents\1321-01-CI18 City of SLO Parks and Rec_Central_ecervantes.rvt 9/4/2019 10:24:13 AM FI N I S H S C H E D U L E & L E G E N D CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N 1321-01-CI18 I-501 09/04/2019 PB EC/SW 90 % P R O G R E S S S E T _ 2 0 1 9 0 9 0 4 ROOM FINISH SCHEDULE wt NAME FLOOR CEILING BASE COUNTER WALL NOTESNORTH SOUTH EAST WEST 101 Lobby LVT-01 PT-01 RB-01 PT-01 PT-01 PT-01 PT-01 102 Reception LVT-01 PT-01 RB-01 SS-01 PT-01 PT-01 PT-01 PT-01 -Refer to Interior Elevation 2/I-201. 103 (E) Staff Conference Room LVT-01 RB-01 PT-01 PT-01 PT-01 PT-01 104 (E) Director Office LVT-01 RB-01 PT-01 PT-01 PT-01 PT-01 105 (E) Supervisor Office LVT-01 RB-01 PT-01 PT-01 PT-01 PT-01 106 Small Conference Room LVT-01 PT-01 RB-01 PT-01 PT-01 PT-01 PT-01 107 (E) Supervisor Office LVT-01 RB-01 PT-01 PT-01 PT-01 PT-01 108 (E) Open Office LVT-01 PT-01 RB-01 PT-01 PT-01 PT-01 PT-01 109 (E) Open Office LVT-01 PT-01 RB-01 PT-01 PT-01 PT-01 PT-01 110 Enclosed Patio N/A N/A N/A N/A N/A N/A N/A 111 (E) Break Room N/A RB-01 PT-01 PT-01 PT-01 PT-01 112 (E) Vestibule LVT-01 PT-01 RB-01 PT-01 PT-01 PT-01 PT-01 -Existing flooring to remain. 113 (E) Janitor Closet N/A N/A PT-01 PT-01 PT-01 PT-01 114 (E) Men's Restroom N/A N/A PT-01 PT-01 PT-01 PT-01 -Existing tiles to remain in restrooms, walls above to be painted 115 (E) Women's Restroom N/A N/A PT-01 PT-01 PT-01 PT-01 -Existing tiles to remain in restrooms, walls above to be painted 116 (E) Shower Room N/A N/A PT-01 PT-01 PT-01 PT-01 -Existing tiles to remain in restrooms, walls above to be painted 117 Copy/File/PC Room LVT-01 ACT-01 RB-01 N/A PT-01 PT-01 PT-01 PT-01 118 (E) Storage LVT-01 PT-01 RB-01 PT-01 PT-01 PT-01 PT-01 -Existing flooring to remain. INTERIOR FINISH LEGEND TAG DESCRIPTION IMAGE MANUFACTURE R SPECIFICATION SIZE LOCATION NOTE LVT-01 Luxury Vinyl Tile Interface Flooring Item: TBD Color: TBD Installation: Random Stagger 4.5" x 36" Flooring PL-01 Plastic Laminate Formica Item: Paloma Bisque Model: 6729-58 Finish: Matte Counters -Bullnose edge PL-02 Plastic Laminate Formica Item: TBD Model: TBD Finish: Matte 1-/34" x 8" Cabinets PT-01 Paint Dunn Edwards Item: TBD Color: TBD Finish: Eggshell Accent Paint RB-01 Rubber Base Johnsonite Item: Traditional Wall Base 4" Color: TBD 4"H Typical Base -Wall base for all areas unless otherwise noted SS-01 Solid Surface Corian Color: Cottage Lane Reception Counters & Wall Cap GE N E R A L N O T E S , L E G E N D & A B B R E V I A T I O N S E-001 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEET NOT F O R CO N S T R U C T I O N rrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017. RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. RP TE RP 2019-06-03 1321-01-CI18 N: \ 1 2 0 0 \ 1 3 2 1 - 0 1 - C I 1 8 - C i t y - o f - S L O - P a r k s - R e c - I n t - O f f i c e - R e h a b \ A r c h i t e c t u r e \ M o d e l \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c . r v t 5/ 3 1 / 2 0 1 9 1 1 : 1 8 : 1 4 A M CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N EXPIRES: 06/30/21 THOMA #18-8157 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com ARE TMA.E C F NO. 10757 EL T S OE A T E SIGER IW LTL IE A RO L I CRT IL FCA AIN HO M N A RE E G I N O Fax: (805) 543-3829 RPD NA OIEFSS L PROG R E S S DRAW I N G S GENERAL NOTES NOT IN CONTRACT ON CENTER NOT TO SCALE NORMAL POWER FACTOR NORMALLY OPEN NIGHT LIGHT MAIN CIRCUIT BREAKER MAIN FUSIBLE SWITCH LOW VOLTAGE LOW PRESSURE SODIUM MAXIMUM OCP MINIMUM CKT AMPS LOCKED ROTOR AMPS QUANTITY 1000 MAIN CATV TERMINAL CABINET MANUAL TRANSFER SWITCH NATIONAL ELECTRICAL CODE LIFE SAFETY BRANCH MAIN TELEPHONE TERMINAL CABINET NEUTRAL (GROUNDED CONDUCTOR) NAT'L ELEC MANUFACTURER'S ASSOC NORMALLY CLOSED MICROWAVE MAIN TELEPHONE TERMINAL BOARD MAIN SWITCHBOARD MAIN LUGS ONLY MOUNTING HEIGHT METAL HALIDE MANUFACTURER MECHANICAL MAIN CATV TERMINAL BOARD MECHANICAL CONTRACTOR LIGHTING CONTACTOR KILOVOLTAMPS NEMA 3R MOUNT LIGHTING LIGHT KILOWATT NPF(F)FUTURE F-#FURNACE OC NTS CURRENT TRANSFORMER CALIFORNIA SFM CONDUIT, CONDUCTOR CONDUIT ONLY (W/PULLROPE) CRITICAL BRANCH COPPER CONDENSING UNIT CONTRACTOR CIRCUIT CENTER LINE EM ES (EXR) EXT (EXN) F EMB EQUIP'T EMERG EOL EC-# EL EM ELEC EF-# EB EC EA (E) CU-# DW DISC DIST DPST DF DIA DC D COND CSFM CT Cu CR C.O. CKT CNT'R CL MHEMERGENCY FLUORESCENT EMERGENCY BALLAST (E) TO BE (R) (E) IN (N) LOCATION ENERGY SAVING EXTERIOR EMERGENCY END OF LINE EQUIPMENT EVENING LIGHT EMERG BATTERY BACKUP ELECTRONIC BALLAST EVAPORATIVE COOLER ELECTRICAL CONTRACTOR ELECTRICAL EXHAUST FAN EXISTING EACH NEC NIC NO NL NEMA N N3R NC (N)NEW MT HT MTTC MTTB MTS MW MOCP MSB MLO MT DOUBLE POLE SINGLE THROW DRINKING FOUNTAIN DIRECT CURRENT DISHWASHER DISTRIBUTION DISCONNECT DIAMETER DEPTH LV MCTC MECH MFS MFR MCTB MCB MCA MC LPS LS LTG LT LRA LC kW kVA k WEATHERPROOF (NEMA 3R)WP INDICATES MOUNTING HEIGHT AFF TRANSFORMER +48 XFMR TIME SWITCH OVERRIDE TWISTED SHIELDED PAIR VANDAL-RESISTANT UNDERWRITERS LABORATORIES SINGLE POLE SINGLE THROW TYPICAL SIMILAR TELEPHONE TERMINAL CABINET VERY HIGH OUTPUT TRANSFORMER, TERMINAL WATER HEATER WIDTH, WATT, WIRE VOLT ALTERNATING CURRENT VOLT AMPERES UG SVC ALERT 800-642-2444 UNLESS OTHERWISE NOTED UNDERGROUND PULL SECTION UNDERCABINET, UNDERCOUNTER TELEPHONE TERMINAL BOARD TELEPHONE COMPANY TO BE REMOVED TELEPHONE CONDUIT SLIMLINE, SWITCH LEG VOLTAGE UNDERGROUND TIME CLOCK TRANSFORMER TIME SWITCH TELEPHONE SURFACE STORAGE SPECIFICATION TTB WH-# USA VHO VAC VOLT VR W VA V VOLT UON UGPS TYP SIM TTC TYP UC UL UG TX TYPICAL T TSP TSO TELCO TEL (TBR) -T- TS TC SURF SVC SPST STR'G SPEC SHT SQ SW SL SQUARE SWITCH SERVICE SHEET COMBINATION STARTER MAGNETIC CONTACTOR DAMPER MOTOR HUMIDISTAT SURFACEMOUNT CABINET FLUSHMOUNT CABINET SURFACEMOUNT PANEL FLUSHMOUNT PANEL PUSHBUTTON HIGH INTENSITY DISCHARGE FIRE ALARM CONTROL PANEL HAND-OFF-AUTO INSIDE FROST IDENTIFICATION HIGH OUTPUT ISOLATED GROUND JUNCTION BOX HORSEPOWER HIGH PRESSURE SODIUM HIGH POWER FACTOR INTERCOM FULL VOLTAGE NON-REVERSING HEATING, AC & REFRIG FULL LOAD AMPS FUSIBLE SWITCH FURNISHED BY OTHERS HEIGHT, HIGH GANG WITH SWITCH GALVANIZED RIGID STEEL GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT CIRCUIT INTERRUPTER GARBAGE DISPOSAL GENERAL CONTRACTOR GROUNDING CONDUCTOR FLUORESCENT FORCED AIR UNIT FIRE ALARM TERMINAL GROUND FLOOR FAN COIL CONDUIT CALIFORNIA FIRE CODE CA. BUILDING CODE CA. ENERGY COMMISSION COMPACT FLUORESCENT CABINET CEILING CA. ELECTRICAL CODE CIRCUIT BREAKER, CODE BLUE CATV CONDUIT CABLE TELEVISION AUTOMATIC TIME SWITCH AMERICAN WIRE GAGE AUTOMATIC TRANSFER SWITCH AMP BREAKER AUDIBLE/AUDIO VISUAL ALUMINUM AMP SWITCH RATING AMPERES INTERRUPTING CAPACITY ABOVE FINISH GRADE ABOVE FINISH FLOOR AMP FUSE, AMP FRAME ALTERNATING CURRENT AIR CONDITIONER ABOVE ABANDONED AMPERE ADJACENT AS -C- CEC CFC CF CLG CBC CAB'T CATV CB BIL BLDG BFG C AV AWG ATS ATS AF AFG AIC AFF Al AC AC-# ABV ADJ AB ABAND A GD BASIC IMPULSE LEVEL BELOW FINISH GRADE BUILDING HO IC J-BOX IF ID IG HOA HPF HPS hp HID HACR GWS H GND GRS GFI GFCI FLUOR FVNR G GC FS FC-# FLA FLR FBO FACP FAU FAT ,a OS W/PILOT LIGHT OCCUPANCY SENSOR WALL OCCUPANCY SENSOR DUAL LEVEL SWITCHING SWITCHLEG DESIGNATION TIMER SWITCH W/THERMAL OVERLOAD DIMMER 3-WAY 4-WAY DPST H M DM SIGNAL CABINET STATE FIRE MARSHAL RATED LOAD AMPS PLANNING & DEVELOPMENT OFFICE of STATEWIDE HEALTH OFFICE of the STATE ARCHITECT POINT OF CONNECTION RIGID METAL CONDUIT PLUMBING CONTRACTOR SHORT CKT CURRENT POWER SECONDARY POWER PRIMARY PUBLIC ADDRESS OUTSIDE DIAMETER REFRIGERATOR OVERCURRENT PROTECTION RAPID START REPLACE REQUIRED PULLBOX PULL CHAIN RECEPTACLE RELOCATE(D) PHOTOCELL OVERHEAD OVERLOAD PC REQ'D RPLC SFM SCC RLA RMC RMV SC RS RM REMOVE ROOM REF POC -PP- -PS- (R) RECEPT PNL ph PHASE PANEL OSHPD OVLD OSA P PB PC PC PA POLE OCP OH OD END OF LINE RESISTOR CHIMEC DUPLEX- FLOOR OUTLET GROUND FAULT CIRCUIT INTERRUPT TV OUTLET-FLOORMOUNT ABOVE-CLGMOUNT J-BOX DROP CORD RECEPT PHONE/DATA COMBO FLOOR OUTLET PHONE/DATA COMBO OUTLET DATA FLOOR OUTLET TELEPHONE FLOOR OUTLET JUNCTION BOX TELEPHONE OUTLET MISCELLANEOUS CIRCUIT BREAKER FUSIBLE SWITCH SAFETY DISCONNECT TELEVISION OUTLET GROUND THERMOSTAT DATA OUTLET FLOORMOUNT 208V, 1Ø RECEPT SINGLE RECEPT. DUPLEX RECEPT. DOUBLE DUPLEX POWER/COMM. DUPLEX- HALF SWITCHED SPECIAL CONFIGURATION NOTE: INTERPRET IN CONTEXT SURFACE FLUOR. SWITCHES A LETTER ADJACENT INDICATES (ARROW INDICATES DIRECTION) FIXTURE TYPE SPST RECESSED WALLMOUNT EXIT LIGHT- CEILING EXIT LIGHT- WALL WALLPACK PHASEØ T MOTOR WALL SURFACEMOUNT LINEAR TYPE UPLIGHT- FLUSH IN GRADE POLE LIGHT- DECORATIVE PENDANT LINEAR FLUOR. UNDERCABINET LIGHT TANDEM-WIRED LAMPS BOLLARD FLUOR. STRIP UON DIRECTIONAL FLOOD EMERGENCY FIXTURE POLE LIGHT TRACK LIGHT J TV CJ TV GFI J LIGHT FIXTURES LEGEND CEILING SURFACEMOUNT WALL SURFACEMOUNT RECESSED DOWNLIGHT RECESSED WALLWASH RECESSED FLUOR. PENDANT MOUNT (E) POWER HOMERUN DUCT SMOKE DETECTOR INDICATES LINE CONTINUES WIRE LINE- CONTINUES CONDUIT STUB (W/MARKER) VERTICAL CONDUIT RUN FLEXIBLE CONNECTION SURFACEMOUNT RACEWAY VISUAL- VISUAL DEVICE MANUAL PULL STATION HORN- AUDIBLE DEVICE AUDIBLE/VISUAL SMOKE DETECTOR HEAT DETECTOR BELL TAMPER SWITCH SD H B D SD T P FLOW SWITCH FIRE ALARM SV V F H CORD W/PLUG LOW VOLTAGELV CONDUIT SEAL NEW POWER HOMERUN (3 HOTS & NEUT SHOWN) CONDUIT/WIRE ISOLATED GROUND EXISTING TO REMAIN NEW E 2 P OS D T 3 4 UNDERGROUND MOUNTED ABOVE COUNTER* MOUNTED ABOVE COUNTER* FIRE ALARM CONTROL PANEL REMOTE POWER SUPPLYRPS ABBREVIATIONS 1.CODE COMPLIANCE: ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH CODES, STANDARDS, AND ORDINANCES AS SET FORTH BY THE AUTHORITIES HAVING JURISDICTION AND THEIR LATEST ADOPTED EDITIONS (IN EFFECT AT TIME OF BUILDING PERMIT APPLICATION) OF THE FOLLOWING PUBLICATIONS: A.CALIFORNIA CODE OF REGULATIONS TITLE 24; INCLUDES 2016 CALIFORNIA ELECTRICAL CODE, 2016 CALIFORNIA FIRE CODE, 2016CALIFORNIA BUILDING CODE, ETC. WITH LOCAL AMENDMENTS AS APPLICABLE. B.AMERICANS WITH DISABILITIES ACT (ADA). 2.SAFETY: THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN A SAFE AND RESPONSIBLE MANNER. KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED. CONDUCT ALL CONSTRUCTION OPERATIONS IN A SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER WORKPERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS, FLAGS, TAPE, ETC. AS REQUIRED FOR SAFETY. THE CONTRACTOR SHALL HOLD ALL PARTIES HARMLESS OF NEGLIGENT SAFETY PRACTICES, WHICH MAY CAUSE INJURY TO OTHERS ON OR NEAR THE JOB SITE. 3.FIRE RATED ASSEMBLIES SHALL MAINTAIN RATINGS AS SPECIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7. CONTRACTOR SHALL PROVIDE AND INSTALL PHYSICAL ENCLOSURE AROUND FIXTURES, PANELS, ETC. AS REQUIRED. ALL ASSEMBLIES TO BE PENETRATED SHALL BE INSTALLED WITH APPLICABLE THROUGH-PENETRATION FIRESTOP SYSTEM AS DETERMINED BY UL CLASSIFICATION. BEFORE CONSTRUCTION, VERIFY AND COMPLY WITH REQUIREMENTS OF LOCAL AUTHORITY HAVING JURISDICTION. 4.MOUNTING HEIGHTS SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: +15" AFF: RECEPTACLES, TELEPHONE, TV & DATA OUTLETS. (MEASURED BOTTOM OF OUTLET BOX) +46" AFF: OUTLET ABOVE COUNTER (MEAUSRED TOP OF OUTLET BOX) +48" AFF: LIGHT SWITCHES. (MEASURED TOP OF OUTLET BOX) +48" AFF: FIRE ALARM MANUAL PULL STATIONS, T-STATS. (MEASURED TOP OF OUTLET BOX) THE LOWER OF +80" AFF TO BOTTOM OF LENS, OR 6" BELOW CEILING: FIRE ALARM VISUALS. ELECTRICAL SWITCHES: CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHT AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. [CBC 11B-308.1.1] ELECTRICAL RECEPTACLE OUTLETS: ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM [CBC 11B-308.1.2] BEFORE ROUGH-IN, VERIFY ALL MOUNTING HEIGHTS AND EXACT LOCATIONS FOR ALL EQUIPMENT ELECTRICAL CONNECTIONS, STUB-UPS, RECEPTACLES, OUTLETS, ETC. WITH ARCHITECT OR OWNER. PLACE DEVICES LOCATED ABOVE COUNTERS, SHELVING, ETC. AND IN BATHROOMS SO AS NOT TO CONFLICT WITH EDGES OF WAINSCOTING, COUNTER SPLASH, SHELVING, ETC. ARCHITECTURAL SHEETS SHALL GOVERN. 4.LABEL PANELS, CABINETS, BACKBOARDS, MAIN DEVICES, SAFETY SWITCHES, CONTACTORS AND OTHER SPECIFICALLY DESIGNATED EQUIPMENT SHOWN ON PLANS. USE ENGRAVED LAMINATED PLASTIC NAMEPLATES ATTACHED BY SCREWS OR RIVETS. FOR FEEDERS, NEATLY AND INDELIBLY LABEL CONDUIT DESTINATIONS ON BOTH VISIBLE ENDS OF CONDUIT RUNS WHERE CONDUITS TERMINATE AT DESIGNATED ENCLOSURES, STRUCTURES OR EQUIPMENT (INCLUDING PULL AND SPLICE BOXES). 5.EQUIPMENT ANCHORAGE NOTE ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED TO MEET THE HORIZONTAL AND VERTICAL FORCES PRESCRIBED IN THE 2013 CBC, SECTIONS 1613A AND 1616A AND ASCE 7-10 SECTIONS 13.3, 13.4 & 13.6. THE ATTACHMENT OF THE FOLLOWING ITEMS SHALL BE DESIGNED TO RESIST THE FORCES PRESCRIBED ABOVE, BUT NEED NOT BE DETAILED ON THE PLANS PER 2013 CBC SECTION 1616A.1.18: A.FURNITURE(EXCEPT STORAGE CABINETS AS NOTED IN 2013 CBC TABLE 13.5-1) B.TEMPORARY OR MOVABLE EQUIPMENT WITH EXCEPTIONS NOTED IN 2013 CBC SECTION 1616A.1.18 ITEM 2. C.ARCHITECTURAL, MECHANICAL, AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, OR F THAT MEET ALL OF THE CRITERIA LISTED IN 2013 SECTION 1616A.1.18 ITEM 3. D.EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUPPORTED BY VIBRATION ISOLATORS. E.EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL/ELECTRICAL ENGINEER. PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTE PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO RESIST THE FORCES PRESCRIBED IN ASCE 7-10 SECTION 13.3 AS DEFINED IN ASCE 7-10 SECTION 13.6.8, 13.6.7, AND 13.6.5.5, ITEM 6, RESPECTIVELY. THE BRACING AND ATTACHMENTS TO THE STRUCTURE SHALL COMPLY WITH ONE OF THE OSHPD PRE-APPROVALS WITH AN OPA#, SUCH AS MASON INDUSTRIES (OPA 349), OR ISAT (OPA 485) AS MODIFIED TO SATISFY ANCHORAGE REQUIREMENTS OF ACI 318, APPENDIX D. COPIES OF THE MANUAL SHALL BE ON THE JOBSITE PRIOR TO STARTING HANGING AND BRACING OF THE PIPE, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS. THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT THE HANGER AND BRACE LOADS. EXISTING BUILDINGS 1.ASBESTOS: IF DURING THE COURSE OF WORK THE CONTRACTOR OBSERVES THE EXISTENCE OF ASBESTOS, OR ASBESTOS-BEARING MATERIALS, THE CONTRACTOR SHALL IMMEDIATELY TERMINATE FURTHER WORK ON THE PROJECT AND NOTIFY THE OWNER OF THE CONDITION. THE OWNER WILL, AFTER CONSULTATION WITH THE OWNER'S REPRESENTATIVE, DETERMINE A FURTHER COURSE OF ACTION. 2.ANY DEMOLITION WORK SHOWN WAS PREPARED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT REPRESENT THAT ALL ITEMS WHICH MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 3.EXISTING CONDITIONS: INFORMATION SHOWN FOR EXISTING CONDITIONS WAS PRIMARILY GAINED FROM "AS BUILT" DRAWINGS AND/OR LIMITED FIELD INVESTIGATION. BEFORE BID, VISIT SITE TO VERIFY EXISTING CONDITIONS AND MAKE ALLOWANCE FOR VARIATIONS FROM THAT SHOWN. 4 EXISTING CONDUCTORS: INTERCEPT, EXTEND, REROUTE, REPULL CONDUCTORS, SPLICE AND OTHERWISE MODIFY EXISTING CONDUCTORS OF ALL SYSTEMS AS REQUIRED TO MAINTAIN AND/OR ESTABLISH PROPER FUNCTION AND SATISFY DESIGN INTENT. REMOVE ABANDONED CONDUCTORS. 5.EXISTING COMMUNICATIONS, DATA AND CATV AND OTHER LOW VOLTAGE TYPE SYSTEM OUTLET LOCATIONS SHOWN ON THE PLAN TO BE RELOCATED SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. MODIFY EXISTING SYSTEM AS REQUIRED FOR FULL FUNCTION (SAME AS EXISTING) IN NEW LOCATION. 6.WHERE EXISTING BUILDING CONSTRUCTION, MECHANICAL UNITS AND OTHER EQUIPMENT IS SHOWN TO BE REMOVED, DISCONNECT AND REMOVE ALL ASSOCIATED ELECTRICAL INSTALLATION. 7.CLOSELY COORDINATE OUTAGE AND FACILITY DISRUPTION TIME WITH ARCHITECT AND OWNER. MINIMUM 72-HOUR NOTICE IS REQUIRED BEFORE ANY CIRCUIT SHUTDOWN OR DISRUPTION OF FACILITY PERSONNEL FUNCTIONING. FILL OR HATCHING INDICATES FIXTURE CONNECTED TO INVERTER UNIT SI N G L E L I N E D I A G R A M & EL E C T R I C A L S C H E D U L E S E-002 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEET NOT F O R CO N S T R U C T I O N rrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017. RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. RP TE RP 2019-06-03 1321-01-CI18 N: \ 1 2 0 0 \ 1 3 2 1 - 0 1 - C I 1 8 - C i t y - o f - S L O - P a r k s - R e c - I n t - O f f i c e - R e h a b \ A r c h i t e c t u r e \ M o d e l \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c . r v t 5/ 3 1 / 2 0 1 9 1 1 : 1 8 : 1 4 A M CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N EXPIRES: 06/30/21 THOMA #18-8157 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com ARE TMA.E C F NO. 10757 EL T S OE A T E SIGER IW LTL IE A RO L I CRT IL FCA AIN HO M N A RE E G I N O Fax: (805) 543-3829 RPD NA OIEFSS L PROG R E S S DRAW I N G S HP A M 400A 2P 200A 2P 2P 200A (E) (1) 4"C. TO PG&E RISER (E) #1/0 (E) 400A, 120/240V, 1Ø, 3W MAIN SWITCHBOARD 'MSB', NEMA 1 SINGLE LINE DIAGRAM (E) (E)(E) (E) PANEL (E) PANEL (E) (3) #3/0 THWN CU, (E) (1) #6 GND + (E) (1) #6 ISO GND IN 2"C. PANEL SCHEDULE NOTES 1. LONG CONTINUOUS LOAD (LCL). ADDITIONAL 25% ADDED AT BOTTOM OF PANEL. FEEDER CALCULATED AT 125% OF TOTAL CONNECTED LOAD. 2.PROVIDE AND INSTALL CIRCUIT BREAKER LOCKING HANDLE OVER THIS BREAKER TO MEET THE REQUIREMENTS OF CEC 210.4. 3.EXISTING BRANCH CIRCUIT TO REMAIN, LOAD SHOWN IS ESTIMATED. 4.NEW CIRCUIT BREAKER TO BE ADDED TO EXISTING PANEL. 1 2 3 4 5 6 7 8 9 11 10 12 13 14 G A B C D E F H I J K (E) Open Office 109 (E) Supervisor Office 107 Small Conference Room 106 (E) Supervisor Office 105 (E) Director Office 104 (E) Mech. Room 119 (E) Electrical Room 120 Copy/File/PC Room 117 (E) Break Room 111 (E) Vestibule 112 (E) Janitor Closet 113 (E) Men's Restroom 114 (E) Women's Restroom 115 (E) Shower Room 116 (E) Staff Conference Room 103 (E) Open Office 108 Reception 102 Lobby 101 (E) Storage 118 NOT IN SCOPE NOT IN SCOPE T F T 1 TYPICAL 2 U.O.N. 333 2 4 5 6 'A' 'HP'6 EL E C T R I C A L D E M O L I T I O N FL O O R P L A N E-101 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEET NOT F O R CO N S T R U C T I O N rrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017. RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. RP TE RP 2019-06-03 1321-01-CI18 N: \ 1 2 0 0 \ 1 3 2 1 - 0 1 - C I 1 8 - C i t y - o f - S L O - P a r k s - R e c - I n t - O f f i c e - R e h a b \ A r c h i t e c t u r e \ M o d e l \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c . r v t 5/ 3 1 / 2 0 1 9 1 1 : 1 8 : 1 4 A M CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N EXPIRES: 06/30/21 THOMA #18-8157 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com ARE TMA.E C F NO. 10757 EL T S OE A T E SIGER IW LTL IE A RO L I CRT IL FCA AIN HO M N A RE E G I N O Fax: (805) 543-3829 RPD NA OIEFSS L PROG R E S S DRAW I N G S REFERENCE NOTES 1.EXISTING LIGHTING FIXTURE TO REMAIN. 2.EXISTING LIGHTING FIXTURE TO BE REMOVED. 3.EXISTING PENDANT MOUNTED LIGHTING FIXTURE TO BE RELOCATED, SEE SHEET E-102 FOR NEW LOCATION. 4.EXISTING LIGHTING CONTROLS TO REMAIN. 5.EXISTING LIGHTING CONTROLS TO BE RELOCATED TO ADJACENT WALL. 6.EXISTING ELECTRICAL PANEL TO REMAIN. NORTH SCALE: ELECTRICAL DEMOLITION FLOOR PLAN 1/8" = 1'-0" GENERAL DEMOLITION PLAN NOTES A. REFER TO ARCHITECTURAL DEMOLITION SHEETS FOR ADDITIONAL INFORMATION. B. EQUIPMENT SHOWN TO BE REMOVED IS SHOWN FOR REFERENCE ONLY. INFORMATION WAS OBTAINED FROM ORIGINAL BUILDING DRAWINGS AND LIMITED FIELD INVESTIGATION AND MAY NOT REPRESENT ALL ELECTRICAL DEMOLITION. FIELD VERIFY CONDITIONS AND DISCONNECT/REMOVE ALL EQUIPMENT AS REQUIRED TO MEET THE INTENT OF THAT SHOWN ON THE LIGHTING AND POWER/SIGNAL DRAWINGS. C. ALL ELECTRICAL EQUIPMENT SHOWN ON DRAWING (OR REQUIRED) TO BE DEMOLISHED SHALL BE DISCONNECTED, REMOVED AND DISPOSED OF BY ELECTRICAL CONTRACTOR. NO EQUIPMENT (RACEWAYS, BOXES, CABLING, ETC.) SHALL BE ABANDONED IN PLACE AND COVERED BY NEW CONSTRUCTION. E. ANY LIGHT SWITCHES THAT ARE NO LONGER IN USE, WHETHER SHOWN ON THE DEMOLITION PLAN OR NOT, ARE TO HAVE THE DEVICE AND WIRING REMOVED, AND A BLANK COVER PLATE INSTALLED. F. SCHEDULE ANY OUTAGES WITH OWNER PRIOR TO DE-ENERGIZATION OF ANY BRANCH CIRCUITS OR FEEDERS. G. DISCONNECTION/REMOVAL OF EXISTING COMMUNICATIONS SYSTEMS COMPONENTS SHALL BE SCHEDULED WITH OWNER AND COORDINATED WITH THEIR VENDORS. H. ALL REMOVED COMPONENTS SHALL BE SALVAGED TO THE OWNER. I. INFORMATION SHOWN FOR LOAD DESCRIPTIONS ON EXISTING PANELS WAS GAINED FROM ORIGINAL BUILDING ELECTRICAL PLANS AND SHALL BE FIELD VERIFIED. CONFIRM LOAD ON EACH CIRCUIT OF ALL EXISTING PANELS AND PROVIDE UPDATED TYPEWRITTEN CIRCUIT DIRECTORY (IN PLASTIC SLEEVE) FOR EACH EXISTING PANELBOARD. J. ANY LOADS REMOVED DURING DEMOLITION SHALL HAVE CONDUCTORS REMOVED BACK TO NEXT REMAINING DEVICE OR TO EXISTING PANELS. ABANDONED BREAKERS SHALL BE LABELED "SPARE". K. PROVIDE BLANK FILLER PLATES IN DEADFRONTS OF EXISTING PANELBOARDS UPON COMPLETION OF PROJECT WHERE BREAKERS HAVE BEEN REMOVED. REF. 1 2 3 4 5 6 7 8 9 11 10 12 13 14 G A B C D E F H I J K (E) Open Office 109 (E) Supervisor Office 107 Small Conference Room 106 (E) Supervisor Office 105 (E) Director Office 104 (E) Mech. Room 119 (E) Electrical Room 120 Copy/File/PC Room 117 (E) Break Room 111 (E) Vestibule 112 (E) Janitor Closet 113 (E) Men's Restroom 114 (E) Women's Restroom 115 (E) Shower Room 116 (E) Staff Conference Room 103 (E) Open Office 108 Reception 102 Lobby 101 (E) Storage 118 Enclosed Patio 110 1 'A' 'HP'1 2 3 (E) TELECOMMUNICATIONS CABINET (N) TELECOMMUNICATIONS CABINET 4 J J J 6 J 6 A-36 5 5 J 6 A-28 A-25,27,35 J 5 A-40 6 25 25 25 25 25 27,35 7 2 HP-21,23,25 23 21 F 8 8 8 9 10 10 A-28 7A-32 A-30 J 5 J 10 12 10 25 A-37,39,41 37 39 39 41 41 41 J 13 EL E C T R I C A L / C O M M U N I C A T I O N S FL O O R P L A N E-102 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEET NOT F O R CO N S T R U C T I O N rrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017. RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. RP TE RP 2019-06-03 1321-01-CI18 N: \ 1 2 0 0 \ 1 3 2 1 - 0 1 - C I 1 8 - C i t y - o f - S L O - P a r k s - R e c - I n t - O f f i c e - R e h a b \ A r c h i t e c t u r e \ M o d e l \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c . r v t 5/ 3 1 / 2 0 1 9 1 1 : 1 8 : 1 4 A M CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N EXPIRES: 06/30/21 THOMA #18-8157 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com ARE TMA.E C F NO. 10757 EL T S OE A T E SIGER IW LTL IE A RO L I CRT IL FCA AIN HO M N A RE E G I N O Fax: (805) 543-3829 RPD NA OIEFSS L PROG R E S S DRAW I N G S 1.ROUTE ALL NEW TELECOMMUNICATIONS CABLING TO NEW TELECOMMUNICATIONS RACK IN STORAGE ROOM 118. 2.ALL TELECOMMUNICATIONS OUTLETS HAVE (3) CAT6 CABLES UNLESS OTHERWISE NOTED. 3.COORDINATE TELECOMMUNICATIONS DEVICE CABLE ROUTING AND FEED POINTS WITHIN MODULAR FURNITURE WITH MODULAR FURNITURE MANUFACTURER. NORTH SCALE: ELECTRICAL / COMMUNICATIONS FLOOR PLAN 1/8" = 1'-0" REFERENCE NOTES 1.EXISTING ELECTRICAL PANEL TO REMAIN, REFER TO PANEL SCHEDULES. 2.DEDICATED RECEPTACLE FOR EQUIPMENT AS SHOWN. 3.ROUTE CABLING FOR DEVICES WITHIN DASHED LINE THROUGH EXISTING FLOORBOX. 4.EXISTING FLOOR BOXES TO REMAIN AND BE USED TO SERVE MODULAR FURNITURE AS SHOWN. FIELD VERIFY EXACT LOCATION. 5.PROVIDE 120V FLEXIBLE SINGLE POINT OF CONNECTION TO MODULAR FURNITURE, COORDINATE WITH MODULAR FURNITURE SUPPLIER. 6.EXISTING J-BOX WITH BRANCH CIRCUITS AS SHOWN TO REMAIN, CONNECT TO NEW MODULAR FURNITURE / NEW RECEPTACLES AS SHOWN. 7.EXISTING J-BOX AND HOMERUN WITH BRANCH CIRCUITS A-25,27, REMOVE EXISTING CONDUCTORS, INSTALL NEW CONDUCTORS REQUIRED TO ADD BRANCH CIRCUIT A-35 AS SHOWN, DISTRIBUTE CIRCUITS 27, AND 35 TO NEW MODULAR FURNITURE AS SHOWN. 8.NEW LOCATION FOR PENDANT FIXTURE, RECONNECT TO EXISTING LIGHTING BRANCH CIRCUIT AND CONTROLS. 9.MOUNT OUTLET IN CASEWORK, RUN ASSOCIATED CONDUIT IN CASEWORK, COORDINATE INSTALLATION WITH CASEWORK SUPPLIER. 10.EXISTING LIGHTING CONTROLS TO REMAIN. 11.EXISTING OUTLET TO REMAIN. 12.PROVIDE FLEXIBLE CONDUIT CONNECTION TO MODULAR FURNITURE FOR LOW VOLTAGE CABLING AS SPECIFIED. 13.EXISTING J-BOC WITH 3/4" CONDUIT TO PANEL A, INSTALL BRANCH CIRCUITS AS SHOWN. GENERAL POWER PLAN NOTES A.FUSING: ALL FUSIBLE SAFETY DISCONNECT SWITCHES SHALL BE PROVIDED WITH DUAL-ELEMENT TIME DELAY TYPE FUSES SIZED AND RATED PER EQUIPMENT MANUFACTURERS' RECOMMENDATIONS. VERIFY WITH EQUIPMENT NAMEPLATE BEFORE INSTALLATION. B.INSTALL SEPARATE NEUTRALS FOR EACH BRANCH CIRCUIT. C.MOTOR OVERLOAD PROTECTION: WHERE REQUIRED BY NEC ARTICLE 430 PART C AND NOT SHOWN ON PLAN OR PROVIDED INTEGRAL WITH EQUIPMENT, PROVIDE AND INSTALL THERMAL OVERLOAD PROTECTION FOR ALL MOTORS. D.DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE, ETC. AND SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER EQUIPMENT. PLAN NOTES GENERAL COMMUNICATION CO M M U N I C A T I O N S R I S E R DI A G R A M & D E T A I L S E-201 NO . REVISION DATE PROJECT MANAGER DRAWN BY CHECKED BY DATE PROJECT NUMBER SHEET NOT F O R CO N S T R U C T I O N rrmdesign.com | (805) 543-1794 3765 S. Higuera, San Luis Obispo, CA 93401 RRM DESIGN GROUP COPYRIGHT 2017. RRM IS A CALIFORNIA CORPORATION THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS. RP TE RP 2019-06-03 1321-01-CI18 N: \ 1 2 0 0 \ 1 3 2 1 - 0 1 - C I 1 8 - C i t y - o f - S L O - P a r k s - R e c - I n t - O f f i c e - R e h a b \ A r c h i t e c t u r e \ M o d e l \ 1 3 2 1 - 0 1 - C I 1 8 C i t y o f S L O P a r k s a n d R e c . r v t 5/ 3 1 / 2 0 1 9 1 1 : 1 8 : 1 4 A M CI T Y O F S A N L U I S O B I S P O P A R K S & RE C R E A T I O N O F F I C E RE H A B I L I T A T I O N EXPIRES: 06/30/21 THOMA #18-8157 San Luis Obispo, CA 93406 P.O. Box 1167 - 3562 Empleo St. THOMA ELECTRIC, INC. Phone: (805) 543-3850 cad@thomaelec.com ARE TMA.E C F NO. 10757 EL T S OE A T E SIGER IW LTL IE A RO L I CRT IL FCA AIN HO M N A RE E G I N O Fax: (805) 543-3829 RPD NA OIEFSS L PROG R E S S DRAW I N G S TELECOMMUNICATIONS RISER DIAGRAM 1.DEVICE SHOWN ARE FOR REFERENCE ONLY, REFER TO FLOOR PLANS FOR EXACT QUANTITIES AND LOCATIONS. 2.PROVIDE PROPER CABLING FOR EACH APPLICATION (WET LOCATION, PLENUM RATED, ETC.) AS APPLICABLE. 3.ALL EQUIPMENT SHOWN IS NEW UNLESS NOTED OTHERWISE OWNER PROVIDED MDF MOUNTED ADMINISTRATIVE EQUIPMENT OWNER PROVIDED ADMIN. FILE SERVERS DATA MDF RACK 120V TYPICAL WORK AREA OUTLET. PROVIDE (3) CATEGORY 6 DROPS TO EACH DATA OUTLET AS SHOWN ON DRAWINGS, U.O.N. FIBER OPTIC PATCH PANEL. PR O V I D E S C D U P L E X 10 0 F X P A T C H C O R D SWITCH PROVIDED AND INSTALLED BY OWNER. SHOWN FOR REFERENCE ONLY CAT 6 PATCH PANELS. PROVIDE CAT 6 PATCH CORDS, QUANTITY AS SPECIFIED STORAGE ROOM 118 TELECOMMUNICATIONS RISER DIAGRAM GENERAL NOTES FIBER OPTIC BACK BONE CABLE FROM EXISTING TELE-COMMUNICATIONS RACK IN COPY/FILE/PC ROOM 117