Loading...
HomeMy WebLinkAboutE - egress from sleeping areas-Code2019 California Residential Code, Title 24, Part 2.5 with July 20215upplement CHAPTER 3- BUILDING PLANNING determined in accordance with Section R322. 2. Located below the design flood elevation provided that the floors are at or above grade on not less than one side, are used solely for parking, building access or storage, meet the requirements of Section R322 and are otherwise constructed in accordance with this code. R309.4 Automatic garage door openers. Automatic garage door openers, if provided, shall be listed and labeled in accor- dance with UL 325. See Health and Safety Code Sections 19890, 19891 and 19892 for additional provisions for resi- dential garage door openers SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS R310.1 Emergency escape and rescue opening required. Basements, habitable attics and every sleeping room shall have not less than one operable emergency escape and rescue opening. where basements contain one or more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping room. Emergency escape and res- cue openings shall open directly into a public way, or to a yard or court that opens to a public way.