Loading...
HomeMy WebLinkAbout01/21/1992, 1 - ADOPTION OF SEISMIC STRENGTHENING STANDARDS FOR UNREINFORCED MASONRY BUILDINGS BY CREATING A NEW APPENDIX CHAPTER IN THE BUILDING CODE.Original agenda report from meeting of 1/7/92 - EXCEPT - Pages 4, 6 and 30. MEETING OA �►�H�I�I►�IIIII�II h �I�IU city Of San UAI S OBI SPO / - -7 -10 . ON COUNCIL AGENDA REPORT ITEM NUMBER: FROM: Arnold Jonas, Community Development Director0 PREPARED BY: Tom Baasch, Chief Building Official SUBJECT: Adoption of seismic strengthening standards for unreinforced masonry buildings by creating a new appendix chapter in the Building Code. CAO RECOMMENDATION: Introduce ordinance to print establishing (1) seismic strengthening standards for buildings of unreinforced masonry (URM) construction, and (2) administrative regulations requiring that all URM buildings be structurally analyzed within 18 months following January 1, 1993 and that any URM building subject to major remodel or occupancy change be strengthened to the established standards. DISCUSSION: During the Council meeting of December 3, 1991, the City Council reviewed the staff report and proposed strengthening ordinance for unreinforced masonry buildings. After considerable discussion, City Council directed staff to submit a revised ordinance and related information at the first meeting in January. Direction included the following: ■ Refine language in the ordinance concerning the beginning date for the 18 -month period during which each owner of a URM building shall have the building structurally analyzed. ■ Outline a plan to gain State recognition of the use of Seismic zone 3 criteria in the City's strengthening standards. • Provide a list of the URM buildings owned by tax exempt entities. • Evaluate the correlation between the compliance deadline in existing fire sprinkler retrofit requirements and the proposed seismic strengthening ordinance. Modifications to Proposed Ordinance Changes to Section A2311(c) of the proposed ordinance (pages 21 and 22) clarify the deadline for completion of the structural analysis required of each URM building owner. The language establishes two documents that are to be issued by the Building Official: 1. A Notice will be sent within 30 days of ordinance adoption reminding the property owner that a "potentially hazardous" building exists on said property. A copy of, V,. city of San l,_,s o81Spo COUNCIL AGENDA REPORT Section 2311(b), which lists the owner's compliance requirements, is to be included with the notice. Reference to the notice in Section 2311(c)4 insures that recordation with the County Recorder will occur soon after passage. 2. An Order directing the owner to obtain and submit to the City the required structural analysis is to be served no earlier than the 30 -day period beginning January 1, 1993. Adequate language has been added to allow the Building Official to defer this action if proposed changes to State codes remain unresolved or conflict with the provisions of the City's strengthening program. The exception to change of occupancy requirements for multi -use buildings (page 21) has also been refined to address a conflict with Section 502 of the Building Code. The language now precludes the application of Section 502 in the case of URM buildings and preserves the less restrictive approach agreed to for multi -use buildings. Wording has also been added to quantify the occupancy change by referencing floor area involved. Seismic Zone 3 Criteria - Staff continues to feel that the use of Zone 3 criteria in the proposed strengthening ordinance is supported by the seismicity study, recent maps published through the National Earthquake Hazard Reduction Program, and by a growing trend among design engineers to rely on a site specific seismic hazard analysis. At the present time, there are no rules or regulations issued by the State which would preclude the use of Zone 3 criteria in the City's technical standards for URM strengthening. As a modification to the Building Code, Zone 3 factors are supported by adequate findings. The concern about future State rulings on this matter remains; future decisions may affect future strengthening projects. However, staff feels that it is premature to achieve resolution at this time and proposes the following action plan: 1. Forward the City's strengthening ordinance to the Seismic Safety Commission after adoption and await their comments. 2. Continue to monitor efforts by the State Building Standards Commission to adopt strengthening standards mandated by AB204. 3. If neither concurrence or resistance to the City's ordinance is received from the State or if conflict between City and State regulations is not obvious, staff will request a written response from the appropriate State agency regarding the legality of the City's modifications to the California Building Code. �,� ��►�w�►�NiI�IIIIIIIIIP° ���II city of San ...Is 061 sp0 Gia; COUNCIL AGENDA REPORT 4. If determined to be prudent after conclusion of items 1- 3, encourage the support of Senator Maddy and Assemblywoman Seastrand towards State acceptance of the City's efforts in utilizing area specific seismic force determination for strengthening criteria. Information suggests that clear indications from item 2 of the plan will not be available for at least 6 months into 1992. Staff will persist in efforts to clarify the issue and inform the Council accordingly. Tax Exempt Properties Staff reviewed data available and determined that there are 15 buildings in the unreinforced masonry building inventory that are owned by tax - exempt entities. The list (attached) consists only of 5 buildings owned by churches and 10 that are government owned. Fire Sprinkler Retrofit Program As summarized in the previous staff report to the City Council, the proposed strengthening ordinance is an interim measure that may ultimately be only a small part of the City's URM mitigation program. Adoption of State regulations pursuant to AB204 and analysis of data collected at the conclusion of the structural analysis period may dictate significant changes to the proposed ordinance. There is the possibility that State regulations will mandate a compliance deadline for URM strengthening that will be consistent with the year 2000 deadline in the fire sprinkler retrofit ordinance. It is important to note that there are 200 buildings located in the downtown fire sprinkler zone that will require fire sprinkler retrofit. Of these, less than 45 percent are URM buildings that would require strengthening. The Fire Chief recommends that pending resolution of the URM strengthening deadline not impede progress in installing fire sprinkler systems in non -URM downtown buildings. Staff recommends that no action concerning the fire sprinkler retrofit deadline be taken at this time and that the action plan on•this issue be as follows: 1. Monitor efforts by the Building Standards Commission to satisfy AB204 during 1992 and report back to the Council as soon clear direction is established. 2. If deadlines for the unreinforced masonry strengthening program remain unclear at the end of 1992, postpone further action on the fire sprinkler retrofit deadline until conclusion of the structural analysis period (approximately July, 1994). ��uN�i�H►�ulllll��P�u►u1111 city of san L _, s 0131 spo i COUNCIL AGENDA REPORT 3. During the periods outlined in items 1 and 2, existing Building and Fire Code requirements for fire sprinkler systems will parallel the proposed strengthening ordinance due to similar language regarding occupancy change and remodeling in excess of 50 percent of replacement cost. CONCURRENCES: The proposed ordinance is supported by the Chamber of Commerce, and the San Luis Obispo Property Owner's Association if the cost of the structural analysis required by the ordinance is considered as a credit towards future City permits to construct strengthening improvements. The position of the BIA was not known prior to the printing of this report; a statement regarding their concurrence will be issued under separate cover. The Fire Chief concurs with the recommendation concerning the fire sprinkler retrofit deadline. FISCAL IMPACT: There are no immediate fiscal impacts for the City. Notice and Order procedures and the processing of building permits for strengthening projects can be accomplished by existing staff. Staff will work with the Seismic Task Force in the coming months to outline a program offering a credit towards City permits for seismic strengthening based on the cost of the initial structural analysis; a recommendation will be submitted to the Council far in advance of the mandatory structural analysis period. SUMMARY: The staff recommended strengthening ordinance as modified by City Council direction represents the conclusion of a process that will establish "state of the art" technical standards for designing structural improvements to unreinforced masonry buildings to achieve the most cost effective reduction in potential seismic hazard, and creates a basic element of a mandatory program to reduce URM hazards. The primary purpose of the ordinance is to improve life safety; the minimum strengthening methodology will limit damage to a URM building and adjacent buildings, but may not prevent irreparable damage. However, the proposed ordinance is reasonable compromise at this time that will begin to provide a safer environment for occupants of a URM building and pedestrians passing by. Because the proposed ordinance does not insure a significant reduction in the URM earthquake hazard, it must be considered an interim measure leading to in a more comprehensive mitigation program satisfying the State mandate. ATTACHMENTS: 1. Legislative Draft 2. Proposed Ordinance 3. List of Tax Exempt Buildings January 10, 1992 LEGISLATIVE DRAFT Revisions to Proposed Unreinforced Masonry Building Strengthening Ordinance Following City Council Meeting of 12 -3 -91 ORDINANCE NO. (1992 SERIES) Administrative Provisions Section A2311. (a) Definitions. For the purposes of this Chapter, the applicable definitions in the Building Code shall apply. (b) Compliance Requirements. 1. The owner of each building within the scope of this Chapter shall, upon service of an order, cause a.structural analysis to be made of the building by an engineer or architect licensed by the state to practice as such. Said analysis shall include the preparation of a report detailing the investigation, evaluation, test data, conclusions, and recommendations to establish compliance with this Chapter. If the building does not comply with seismic standards established in this Chapter, the report shall specify the work and cost necessary to structurally alter the building to conform to such standards. The Building Official shall establish a basic outline for the format of the report. 2. The owner of a building within the scope of this Chapter shall comply with the requirements set forth above by submitting the analysis report to the Building Official for review and acceptance within 18 months of the service of an order. 3. The owner of a building within the scope of this Chapter shall structurally alter the building to conform to the seismic standards of this Chapter or cause the building tq be demolished when either of the following occurs: A. The value of additions, alterations, and /or repairs, cumulative from the effective date of this Chapter, exceeds 50 percent of the replacement value of the building established by the Building Official per Section 304(b) of the Uniform Administrative Code. B. The use of the building changes to a different division of the same group of occupancy or to a different occupancy group. (d) EXCEPTION: containing more than one occupancy classification need not comply with this Chapter if m< €a changes in use, cumulative from the J \N;::.i:ri: \i::Yii'i:�iYri4: %{.:i {4:i:6M. i >:i: effective date of this Chapter, de d not exceed 50 percent of the floor area of the building. 4. This Chapter does not require alteration of existing electrical, plumbing, mechanical, or fire safety systems. Administration. 2. order eententso be in I. order 8ervies. The Building 9ffieial shall, within 30 days of the effective- mate —of this ehapter, , I.. . :fin eefaalleed assessment / 2. order eententso be in The —erde= steal shall be served either al l registered mail upen the-ewner as shown writing by .mot t'ie en the last and in eefaalleed assessment / / / speeify that the building has been determined by the /� l Beilding a € €ielal to to within the seepe —e and, there ere,— s ,J r ed to —meet the minimum -- -- standa2ds e€ t is chapter. The ardor shall -peel -fy the tang _las i fiea s -_ of the building l di ng an shall l }a. 3. Appeal. The owner of the building may appeal the Building Official's initial determination that the building is within the scope of this Chapter to the Board of Appeals established by Section 204 of the Uniform Administrative Code. Such appeal shall be filed with the Board within 60 days from the service date of the order described in Section A2311(c)2. Appeals or requests for modifications from any other determinations, orders or actions by the Building Official pursuant to the Chapter shall be made in accordance with the procedures established in Sections 107, 108 and 204 of the Uniform Administrative Code. Any appeal shall be decided by the Board no later than 90 days after filing and the grounds thereof shall be stated clearly and concisely. 4. Recordation. At the time that the Building Official serves the aforementioned ender oiw , the Building Official shall also file and record with the office of the county recorder a certificate stating that the subject building.is within the scope of this Chapter and is a potentially earthquake hazardous building. The certificate shall also state that the owner thereof has been ordered to structurally analyze the building to determine compliance with this Chapter. If the building is either demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building Official shall file and record with the office of the county recorder a form terminating the status of the subject building as being classified within the scope of / -7 this Chapter. 5. Enforcement. If the owner in charge or control of the subject building fails to comply with any order issued by the Building Official pursuant to this Chapter within the time limit set forth in Section A2311(b), the Building Official shall verify that the record owner of this building has been properly served. If the order has been served on the record owner, then the Building Official shall order that the entire building be vacated and that the building remain vacated until such order has been complied with. If compliance with such order has not been accomplished within 90 days after the date the building has been ordered vacated or such additional time as may have been granted by the Board of Appeals, the Building Official may order its demolition in accordance with the provisions of section 203 of the Uniform Administrative Code. 6. Annual Report. During January of each year, the Building Official shall submit a report to the City Council outlining the progress to date concerning reduction of the hazards presented by the unreinforced masonry building inventory for the City. The report shall include: A. The number of unreinforced masonry buildings strengthened, demolished, or otherwise eliminated from the inventory; B. The number of unreinforced masonry buildings remaining on the inventory, including the status of orders issued pursuant to this Chapter that are not resolved. 1 ' 40 ORDINANCE NO. (1992 Series) AN ORDINANCE OF THE CITY OF SAN LUIS OBISPO AMENDING TITLE 15, CHAPTER 15.04 OF THE MUNICIPAL CODE TO ADD DIVISION III OF APPENDIX CHAPTER 23 TO THE UNIFORM BUILDING CODE AS ADOPTED AND TO ESTABLISH FINDINGS OF FACT TO SUPPORT THE IMPOSITION OF REQUIREMENTS GREATER THAN REQUIREMENTS ESTABLISHED BY THE STATE BUILDING STANDARDS CODE WHEREAS, it is the desire and intent of the City Council of the City of San Luis Obispo to provide citizens with the greatest degree of life and structural safety in unreinforced masonry buildings in the most cost effective manner by amending the 1988 editions of the Uniform Building Code and Uniform Building Code Standards as adopted to add requirements for strengthening buildings of unreinforced masonry construction; and WHEREAS, the California Health and Safety Code, Chapter 4, Part 1.5, Division XIII, Section 17958, Section 17958.5 and Section 17958.7 requires the City Council, before making any modifications or changes to the State Building Standards Code pursuant to Health and Safety Code Section 17958.5, to make an express finding that each such modification or changer is needed; and, WHEREAS, the California Health and Safety Code Section 17958.5 requires that such changes must be determined to be reasonably necessary because of local climatic, geological, or topographical conditions; and, WHEREAS, such findings must be made available as a public record and a copy thereof with each such modification or change shall be filed with the State of California Department of Housing and Community Development; and WHEREAS, the City Council of the City of San Luis Obispo hereby determines that the addition of Division III of Appendix Chapter 23 to the 1988 Uniform Building Code and Standards No. 24 -40, 24- 41, and 24 -42 to the 1988 Uniform Building Code Standards due to the findings contained herein are greater requirements than those set forth in the California State Building Standards Code; and WHEREAS, the City Council of the City of San Luis Obispo finds that each of the changes or modifications to measures referred to herein are reasonably necessary because of local climatic, geological, or topographical conditions in the area encompassed by the boundaries of the City of San Luis Obispo, and that the following findings support the local necessity for the changes or modifications: FINDING 1 That the City of San Luis Obispo contains approximately 137 buildings considered to be of unreinforced masonry construction Ordinance No. (1991 Series) Page 2 and defined as "potentially hazardous" during a seismic event. An unreinforced masonry building has proven to be particularly susceptible to damage during an earthquake. The protection of occupants in potentially hazardous buildings and the general public and preservation of property in the event of such occurrence support the imposition'of structural requirements greater than those set forth in the California State Building Standards Code and in particular support the addition of Appendix Chapter 23- Division III to the 1988 Uniform Building Code. FINDING 2 That the City of San Luis Obispo is situated near three major faults each capable of generating earthquakes with a magnitude of 7.5. These are the San Andreas to the east of the City, the Nacimiento - Rinconada that crosses Hwy 101 north of the City then parallels the City to the east, and the Hosgri to the West.. Other faults of importance are the Huasna and West Huasna to the Southeast of the City, the San Simeon to the Northwest, and the Edna and Edna Extended faults which enter the southern areas of the City. In as much as these faults are included as major California earthquake faults, which are subject to becoming active at any time, the City of San Luis Obispo is particularly vulnerable to devastation should such an earthquake occur. The protection of human life and the preservation-of property in the event of such an occurrence support the imposition structural requirements not set forth in the California State Building Standards Code and in particular support the addition of Appendix Chapter 23- Division III to the 1988 Uniform Building Code. FINDING 3 That the City of San Luis Obispo is located in Seismic Zone 4 and is subject to the provisions of Chapter 12.2, Division 1 of Title 2 of the Government Code. Government Code Section 8875 et seq. requires that the City establish a mitigation program to reduce the hazards associated with unreinforced masonry buildings. The mandate by the State of California to mitigate the hazards of such buildings supports the imposition of structural requirements greater than those set forth in the California State Building Standards Code, and in particular, supports the addition of. Appendix Chapter 23- Division III to the 1988 Uniform Building Code. FINDING 4 That adoption of the Ordinance in and of itself will not have the potential for environmental effects. Most seismic strengthening projects will not be visible on the exterior of the involved structure, requiring ministerial approval of building permits for attachment of the roof structure to walls and similar operations. Those projects involving change of occupancy, architectural review, or more extensive permit activity will require specific environmental review prior to their approval. Ordinance No. (1991 Series) Page 3 NOW THEREFORE BE IT ORDAINED by the City Council of the City Of San Luis Obispo that the provisions of the State Building Standards Code are hereby modified, changed and amended, as provided for herein, based upon the foregoing findings and the public interest in protecting life•and preserving public safety and property, as follows: SECTION 1. Chapter 15.04 of Title 15 of the San Luis Obispo Municipal Code is hereby amended by adding subsection Q to Section 15.04.040 as follows. SECTION 15.04.040 AMENDMENTS; UNIFORM BUILDING CODE Q. Amend the Appendix to Chapter 23 by adding Division III to read as follows: Chapter 23 Division III SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BUILDINGS Purpose Section A2301. The purpose of this Chapter is to promote public safety and welfare by reducing the risk of death or injury that may result from the effects of earthquakes on existing buildings of unreinforced masonry wall construction. The provisions of this Chapter are intended as minimum standards for structural seismic resistance established primarily to reduce the risk of life loss or injury. Compliance with these standards will not necessarily prevent loss of life or injury or prevent earthquake damage to rehabilitated buildings. Scope Section A2302. The provisions of this Chapter shall apply to all existing buildings having at least one unreinforced masonry wall. Except as provided herein, all other provisions of the Building Code shall apply. EXCEPTION: This Chapter shall not apply to detached one or two family dwellings and detached apartment houses containing less than 5 dwelling units and used solely for residential purposes. Definitions Section A2303. For the purposes of this Chapter, the applicable definitions in the Building Code shall also apply. COLLAR JOINT is the vertical space between adjacent wythes and / %-I I Ordinance No. 1991 Series) Page 4 may contain mortar. CROSSWALL is a wall that meets the requirements of Section A2309(d)3. A crosswall is not a shear wall. CROSSWALL SHEAR CAPACITY is the length of the crosswall• times the allowable shear value, VcLc. DIAPHRAGM EDGE is the intersection of the horizontal diaphragm and a shear wall or other line of shear collection. DIAPHRAGM SHEAR CAPACITY is the depth of the diaphragm times the allowable shear value, vUD. FLEXIBLE DIAPHRAGM is a diaphragm of wood construction or other construction of similar flexibility. NORMAL WALL is a wall perpendicular to the direction of seismic forces. OPEN FRONT is an exterior building wall plane on one side only without vertical elements of the lateral force resisting system in one or more stories. POINTING is the partial reconstfuction of the bed joints of a URM wall as defined in U.B.C. Standard No. 24 -42. UNREINFORCED MASONRY (URM) WALL is a masonry wall in which the area of reinforcing steel is less than 25 percent of the minimum required by the Building Code for reinforced masonry. UNREINFORCED MASONRY BEARING WALL. A URM wall which provides the vertical support for a floor or roof for which the total superimposed load exceeds 100 pounds per linear foot of wall. YIELD STORY DRIFT is the lateral displacement of one level relative to the level above or below at which yield stress is first developed in a frame member. Symbols and Notations Section A2304. For the purposes of this Chapter, the applicable symbols and notations in the Building Code shall also apply. A = Area of unreinforced masonry pier, square inches. Ae = Area of the bed joints above and below the test specimen for each in -place shear test. C = Numerical coefficient specified in Table A23 -A of this Chapter. D = In -plane width dimension of pier, inches, or depth of /�;-12. Ordinance No. (1991 Series) Page 5 diaphragm, feet. DCR = Demand - capacity ratio specified in Section A2309(d). Fp = Wall anchor tension force, pounds. FWx = Force applied to a wall at level x, pounds. H = Least clear height of opening on either side of pier, inches. h/t = Height /thickness ratio of URM wall. Height h is measured between wall anchorage levels and /or slab -on- grade. L = Span of diaphragm between shear walls, or span between shear wall and open front, feet. LC = Length of crosswall, feet. Li = Effective span for an open front building specified in Section A2309(d)7, feet. Pp = Superimposed dead load at the top of the pier under consideration, pounds Pd = Axial dead load pressure, pounds per square inch. PW = Weight of wall, pounds. Va = The allowable shear in any URM pier, pounds. Vcb = Total shear capacity of crosswalls in the direction of analysis immediately below the diaphragm level being investigated, EvCLC, pounds. VC8 = Total shear capacity of crosswalls in the direction of analysis immediately above the diaphragm level being investigated, EvCLC, pounds. Vr = 0.5Pp(D /H), the rocking shear of any URM wall or wall pier, pounds. VW = Total shear force resisted by a shear wall at the level under consideration, pounds. VP = Shear force assigned to a pier on the basis of its relative shear rigidity, pounds. VS = Shear force assigned to a spandrel on the basis of the shear forces in the adjacent wall piers and tributary dead plus live loads. Vtesc = Load in pounds at incipient slipping for each in -place /5 -13 Ordinance No. 11991 Series) Page 6 shear test per Section A2306(c)3A. ve = Allowable shear stress for unreinforced masonry, pounds per square inch. vc = Allowable shear value for a crosswall sheathed with any of the materials given in Tables A23 -C or A23 -D, pounds per foot-. vt = Mortar shear strength as specified in.Section A2306(c)3D. vto = Mortar shear test values as specified in Section A2306(c)3D. vu = Allowable shear value for a diaphragm sheathed with any of the materials given in Tables A23 -C or A23 -D, pounds per foot. EVuD = Sum of diaphragm shear capacities of both "ends of the diaphragm. EEVUD= For diaphragms coupled with crosswalls EEv,D includes the sum of shear capacities of both ends of diaphragms coupled at and above the level under consideration. Wd = Total dead load tributary to a diaphragm, pounds. EWd = Total deal load tributary to all of the diaphragms at and above the level under consideration, pounds. WP Wall dead load tributary to an anchor, pounds. Ww = Total dead load of an unreinforced masonry wall above the level under consideration or above an open front of a building, pounds. Wwx = Dead load of a URM wall assigned to Level x halfway above and below the level under consideration. Z = The Seismic Zone Factor for Seismic Zone 3 specified in Table 23 -I of the Building Code. General Requirements Section A2305. (a) General. All buildings shall have a seismic resisting system conforming with Section 2303(b) of the Building Code, except as modified by this Chapter. (b) Alterations and Repairs. Alterations and repairs required to meet the provisions of this Chapter shall comply with all other applicable requirements of the Building Code unless specifically provided for in this Chapter. /0-4 Ordinance No. Page 7 (c) Requirements information shall Chapter: (1991 Series) for Plans. The following construction be included in the plans required by this 1. Accurately dimensioned floor and roof plans showing existing walls and the size and spacing of floor and roof framing members and sheathing materials. The plans shall indicate all existing and new crosswalls and their materials of construction. The location of the crosswalls and their openings shall be fully dimensioned or drawn to scale on the plans. 2. Accurately dimensioned wall elevations showing openings, piers, thicknesses, and heights, wall shear test locations, cracks or damaged portions requiring repairs. The general condition of the mortar joints and if and where the joints require pointing. Where the exterior face is veneer, the type of veneer, its thickness and its bonding and /or ties to the structural wall masonry shall also be reported. 3. The type of interior wall and ceiling surfaces. 4. The extent and type of existing wall anchorage to floors and roof when utilized in the design. 5. The extent and type of parapet corrections which were previously performed, if any. 6. Repair details, if any, of cracked or damaged unreinforced masonry walls required to resist forces specified in the Chapter. 7. All other plans, sections, and details necessary to delineate required retrofit construction including those items in Section A2310. Material Requirements Section A2306. (a) General. All materials permitted by this Chapter, including their appropriate allowable design values and those existing configurations of materials specified herein, may be utilized to meet the requirements of this Chapter. (b) Existing Materials. All existing materials utilized as part of the required force resisting system shall be in sound condition or shall be repaired or removed and replaced with new material. (c) Existing unreinforced Masonry. 1. General. All unreinforced masonry walls utilized to carry vertical loads or seismic forces parallel and /$-1,5 Ordinance No. (1991 Series) Page 8 perpendicular to the wall plane shall be tested as specified in this subsection. All masonry that does not meet or exceed the minimum standards established by this Chapter shall be removed and replaced by new materials or alternatively shall have its structural functions replaced by new materials and shall be anchored to supporting elements. 2. Lay -Up of Walls. The facing and backing shall be bonded so that not less than 10 percent of the exposed face area is composed of solid headers extending not less than 4 inches into the backing. The clear distance between adjacent full- length headers shall not exceed 24 inches vertically or horizontally. Where the backing consists of two or more wythes, the headers shall extend not less than 4 inches into the most distant wythe or the backing wythes shall be bonded together with separate headers whose area and spacing conform to the foregoing. Wythes of walls not bonded as described above shall be considered as veneer. Veneer wythes shall not be included in the effective thickness.used in calculating the height to thickness and the shear capacity of the wall. EXCEPTION: Veneer wythes, anchored as specified by the Building Code and made composite with backup masonry, can be used for calculation of the effective thickness. 3. Mortar. A. Tests. The quality of mortar in all masonry walls shall be determined by performing in -place shear texts in accordance with U.B.C. Standard No. 24 -40. Alternative methods of testing may be approved by the Building Official for masonry walls other than brick. B. Location of Tests. The shear tests shall be taken at locations representative of the mortar conditions throughout the entire building, taking into account variations in workmanship at different building height levels, variations in weathering of the exterior surfaces, and variations in the condition of the interior water and /or by the deleterious effects of other substances contained within the building. The exact test location shall be determined at the building site by the engineer in responsible charge of the structural design work. An accurate record of all such tests and their location in the building shall be recorded and these results shall be submitted to the Building Department for approval as part of the structural analysis. C. Number of Tests. The minimum number of tests shall be as follows: /,6 -1(40 Ordinance No. (1991 Series) Page 9 (1) At each of both the first and top stories, not less than two per wall or line of wall elements providing a common line of resistance to lateral forces. (2) At each of all other stories, not less than one per wall or line of wall elements providing a common line of resistance to lateral forces. (3) When grouted or chemically set tension anchors are utilized above the roof line additional in -plane shear tests shall be performed above the intersection of the roof sheathing with the wall. The test locations shall be distributed around the perimeter of the building such that a minimum of one test is performed in each predominant wall direction. The minimum quality mortar in each of the shear tests shall not be less than 50 psi. (4) In any case, not less than one per 1500 square feet of wall surface nor less than a total of eight. D. Minimum Quality Mortar. (1) Mortar shear test values, vto, in psi shall be obtained for each in -place shear test in accordance with the following equation: vto = (vtest /Ab ) -Pd .................. (A23 -1) (2) The mortar shear strength, vt, is the value in psi that is exceeded by 80% of all of the mortar shear test values, vto . (3) Unreinforced masonry with mortar shear strength, vt, less than 30 psi shall be removed or pointed and retested. E. Collar Joints. The collar joints shall be inspected at the test locations during each in -place shear test, and estimates of the percentage of the surfaces of adjacent wythes which are covered with mortar shall be reported along with the results of the in -place shear tests. F. Pointing. All deteriorated mortar joints in unreinforced masonry walls shall be pointed according to U.B.C. Standard No. 24 -42. Nothing shall prevent pointing with mortar of all the masonry wall joints before the tests are made, except as required by Section A2307(a). Alternative methods of pointing may be used with prior approval of the Building Official. / X-�/ 7 Ordinance No. 11991 Series) Page 10 (d) Existing wall Anchors. Existing wall floor anchors, if found to be acceptable by testing, may be utilized in the design. Anchors utilized as all or part of the required tension anchors shall be tested in pullout according to U.B.C. Standard No. 24- 41. The minimum number of anchors tested shall be four per floor, with two tests at walls with joists framing into the wall and two tests at walls with joists parallel to the wall, but not less than ten percent of the total number of existing tension anchors at each level. Quality Control Section A2307. (a) Pointing. All preparation and mortar pointing shall be performed with special inspection. EXCEPTION: At the discretion of the Building Official, incidental pointing may be performed without special inspection. (b) New Bolts. One- fourth of all new shear bolts and combined tension and shear bolts in unreinforced masonry walls shall be tested-according to U.B.C. Standard 24 -41. EXCEPTION: Special inspection may be provided during installation in lieu of testing. (c) New Anchors. All installation of grouted or chemically set tension anchors shall be performed with special inspection. Allowable Design Values Section A2308. (a) Allowable Values. 1. Allowable values for existing materials are given in Table A23-C and for new materials in Table A23 -D. 2. Allowable values not specified in this Chapter shall be as specified elsewhere in the Building Code. (b) Masonry Shear. The allowable unreinforced masonry shear stress, v., shall be determined from the following equation: ve = 0.lvt + 0. 15PD/ A ....... ........................(A23 -2) The mortar shear test value, vt, shall be determined in accordance with Section A2306(c)3, and shall not exceed 100 psi for the determination of v.. The one -third increase in allowable values of the Building Code is not allowed for v.. (c) Masonry Compression. Where any increase in dead plus live / -l8 Ordinance No. (1991 Series) Page 11 compression stress occurs the allowable compression stress in unreinforced masonry shall not exceed 100 psi. The one -third increase in allowable stress of the Building Code is allowed. (d) Masonry Tension. Unreinforced masonry shall be assumed as having no tensile capacity. (e) Existing Tension Anchors. The allowable resistance values of the existing anchors shall be 40 percent of the average of the tension tests of existing anchors having the same wall thickness and joist orientation. The one -third increase in allowable stress of the Building Code is not allowed for existing tension anchors. (f) Foundations. For existing foundations new total loads may be increased over existing loads by 25 percent. New total dead load plus live load plus seismic forces may be increased over existing dead load plus live load by 50 percent. Higher values may be justified only in conjunction with a geotechnical investigation. Analysis and Design Section A2309. (a) General. Except as modified herein, the analysis and design relating to the structural alteration of existing buildings shall be in accordance with the Building Code. (b) Selection of Procedure. Buildings shall be analyzed by the General Procedure of Section A2309(c) which is based on Chapter 23 of the Building Code, or when applicable, buildings may be analyzed by the Special Procedure of A2309(d). Unreinforced masonry bearing wall buildings constructed of hollow concrete or clay tile shall be analyzed-by the general procedures unless it can be shown by testing that all masonry units were manufactured and installed in compliance with U.B.C. Standards No. 24 -4 or 24- 8 as applicable for bearing type units and that the capacity of the wall in bearing and shear, based on the net area in contact through the bed joints, is not less than that allowed for solid bricks, in which case the special procedure may be used. Buildings with a substantially complete steel or concrete frame capable of supporting gravity dead and live loads and that utilize unreinforced masonry walls as non - bearing infill between frame members shall be analyzed by a procedure approved by the building official. Qualified historic structures may be analyzed per Title 24, California Administrative Code, Part 8, State Historical Building Code. (c) General Procedure. 1. Minimum Design Lateral Forces. Buildings shall be analyzed to resist minimum lateral forces assumed to act noncurrently in-the direction of each of the main axes of the structure in accordance with the following: /;5-19 Ordinance No. k1991 Series) Page 12 V = 0. 33ZW ............. ........................(A23 -3) 2. Lateral Forces on Elements of Structures. Parts or portions of structures shall be analyzed as required in Chapter 23 of the Building Code. EXCEPTIONS: 1. Unreinforced masonry walls for which height -to- thickness ratios do not exceed ratios set forth in Table A23 -B need not be analyzed for out -of- plane loading. Unreinforced masonry walls which exceed the allowable h/t ratios of Table A23 -B shall be braced according to Section A2310(e). 2. Parapets complying with Section A2310(f) need not be analyzed for out -of -plane loading. 3. Shear Walls (In -Plane Loading). Shear walls shall comply with subsection A2309(e). (d) Special Procedure. 1. Limits for the Application of Subsection A2309(d). The Special Procedure of this subsection may only be applied to buildings with the following characteristics: A. Flexible diaphragms at all levels above the base of the structure. B. A maximum of 6 stories above the base of the building. C. The vertical elements of the lateral force resisting system shall consist predominantly of masonry or concrete shear walls. D. New vertical elements of the lateral force resisting system consisting of steel braced frames or special moment resisting frames shall have a maximum overall height -to- length ratio of 1 -1/2 to 1. E. A minimum of two lines of vertical elements of the lateral force resisting system shall be parallel to each axes of the building except for single -story buildings with an open front on one side only. (See Section A2309(d)8 for open front buildings.) 2. Lateral Forces on Elements of Structures. With the exception of the diaphragm provisions in subsection 12309(d), elements of structures shall comply with subsection A2309(c)2. 3. Crosswalls. Crosswalls shall meet the requirements of this subsection. 0 _� Ordinance No. (1991 Series) Page 13 A. Crosswall Definition. A crosswall is a wood - framed wall sheathed with any of the materials described in Tables A23 -C or A23 -D. Spacing of crosswalls shall not exceed 40 feet on center measured perpendicular to the direction of consideration, and shall be placed in each story of the building. Crosswalls shall extend the full story height between diaphragms. EXCEPTIONS: 1. Crosswalls need not be provided at all levels in accordance with subsection A2309(d)4B(iv). 2. Existing crosswalls need not be continuous below a wood diaphragm at /or within four feet of grade provided: (i) Shear connection requirements Section A2309(d)5 are satisfied at all edges of the diaphragm. (ii) Crosswalls with total shear capacity of 0.20ZEWa interconnect the diaphragm to the foundation. (iii) The demand /capacity ratio of the diaphragm between the crosswalls that are continuous to their foundations shall be calculated as: DCR = (0.75ZWd + Vca 1/2VuD...... (A23 -4) and DCR shall not exceed 2.5. B. Crosswall Shear Capacity. measured along the span of the the crosswall shear capacities percent of the diaphragm shear strongest diaphragm at or abov, consideration. Within any 40 feet diaphragm, the sum of shall be at least 30 capacity of the the level under C. Existing Crosswalls. Existing crosswalls shall have a length -to- height ratio between openings of not less than 1.5. Existing crosswall connections to diaphragms need not be investigated as long as the crosswall extends to the framing of the diaphragm above and below. D. New Crosswalls. New crosswall connections to the diaphragm shall develop the crosswall shear capacity. New crosswalls shall have the capacity to resist an overturning moment equal to the crosswall shear capacity times the story height. Crosswall overturning moments need not be cumulative over more than two 10-2.1 ordinance No. X1991 Series) Page 14 stories. E. other Crosswall Systems. Other systems such as special moment resisting frames may be used as crosswalls provided that the yield story drift does not exceed 1 inch in any story. 4. Wood Diaphragms. A. Acceptable Diaphragm Span. A diaphragm is acceptable if the point (L,DCR) on Figure A23 -1 falls within Regions 1, 2 or 3. B. Demand- Capacity Ratios. Demand - Capacity Ratios shall be calculated for the diaphragm according to the following formulas: (i) For a diaphragm without qualifying crosswalls at levels immediately above or below: DCR = 0. 75ZWd /Ev,D ..................(A23 -5) (ii) For a diaphragm in a single -story building with qualifying crosswalls: DCR = 0.75ZWd /(EvuD + Vcb) .......... (A23 -6) (iii) For diaphragms in a multi -story building with qualifying crosswalls in all levels: DCR = 0.75ZEWd /(EEvuD + Vcb) ......... (A23 -7) DCR shall be calculated at each level for the set of diaphragms at and above the level under consideration. In addition, roof diaphragm shall also meet the requirements of Formula A23 -6. (iv) For a roof diaphragm and the diaphragms directly below if coupled by crosswalls: DCR = 0.75ZEWd /EEvuD .................. (A23 -8) C. Chords. An analysis for diaphragm flexure need not be made and chords need not be provided. D. Collectors. An analysis, of diaphragm collector forces shall be made for the transfer of diaphragm edge shears into vertical elements of the lateral force resisting system. Collector forces may be resisted by new or existing elements. E. Diaphragm openings. (i) Diaphragm forces at corners of openings shall 16-22-,. Ordinance No. (1991 Series) Page 15 be investigated and shall be developed into the diaphragm by new or existing materials. (ii) In addition to calculating demand - capacity ratios per Section A2309(d)4B, the demand - capacity ratio of the portion of the diaphragm adjacent to an opening shall be calculated using the opening dimension as the span. (iii) Where an opening occurs in the end quarter of the diaphragm span, v D for the demand - capacity ratio calculation shall to based on the net depth of the diaphragm. 5. Diaphragm Shear Transfer. Diaphragms shall be connected to shear walls with connections capable of developing a minimum force given by the lesser of the following formulas: V = 0. 50ZCpWd .......... ........................(A23 -9) using C values of Table No.. 23 -A, or V = VUD ..............- .......................(A23 -10) 6. Shear Walls (In -Place Loading) - Special Procedure. A. Wall Story Force. The wall story force distributed to a shear wall at any diaphragm level shall be the lesser value calculated as: (i) For buildings without crosswalls: FwX = 0.33Z(WWX +Wd /2) ............. (A23 -11) but need not exceed FwX = 0.33ZWWX + VUD ................(A23 -12) (ii) For buildings with crosswalls in all levels: FWX = 0.25Z( Wax +Wd /2) ...............(A23 -13) but need not exceed FUX = 0.25Z (WWX +EWd (vuD /EEvuD+Vcb )) .. (A23 -14) and need not exceed FwX = 0.25ZWWX + VUD ................(A23 -15) B. Wall Story Shear. The wall story shear shall be the sum of the wall story forces at and above the level of consideration. / O -Z3 Ordinance No. (1991 Series) Page 16 Vwx = EFwx ........ .......................(A23 -16) C. Shear Wall Analysis. Shear walls shall comply with subsection A2309(e). D. Moment Frames. shear walls shall be of the Building Code specified in Section drift ratio shall be further limited in S, Moment frames used in place of designed as required in Chapter 23 except that the forces shall be as A2309(d)6A and the interstory limited to 0.005 except as for 2ction A2309(e)3B. 7. Buildings with Open Fronts. A building with an open front on one side shall, have crosswalls parallel to the open front and shall be designed by the following procedure: A. Effective Diaphragm Span, L,, for use in Figure A23 -1 shall be determined in accordance with the following formula: Li = 2[(Ww /Wd) x L + L] ..................(A23 -17) B. Diaphragm demand - capacity ratio shall be calculated as: DCR = 0.75Z9Wd + Ww) /((vuD) + Vc] ........ (A23 -18) (e) Analysis of Vertical Elements of the Lateral Force - Resisting System. Applicable to both General Procedure and Special Procedure Buildings. 1. Existing URM Walls. A. Flexural Rigidity. Flexural components of deflections may be neglected in determining the rigidity of a URM wall. B. Shear Walls with Openings. Wall piers shall be analyzed according to the following procedure: (i) For any pier, (1) The pier shear capacity shall be calculated as: Ve = VeA ....................... (A23 -19) (2) The pier rocking shear capacity shall be calculated as: Vr = 0. 5PDD /H ..................(A23 -20) (ii) The wall piers at any level are acceptable if they comply with one of the following modes of / t -2�f Ordinance No. (1991 Series) Page 17 behavior: (1) Rocking Controlled Mode. When the pier rocking shear capacity is less than the pier shear capacity, i.e. Vr < V. for each pier in a level, forces in the wall at that level, V ,,x, shall be distributed to each pier, VP, in proportion to PDD /H. For the wall at that level: Vwx < EVE ...................... (A23 -21) (2) Shear Controlled Mode. Where the pier shear capacity is less than the pier rocking capacity, i.e. V. < V�, in at least one pier in a level, forces in the wall at that level, VW., shall be distributed to each pier, VP, in proportion to D /H. For at least one pier at that level: VP < Va . .......................(A23 -22) and VP < Vr : .......................(A23 -23) If VP < Va for each pier and V > Vr for one or more piers, omit such piers from the analysis and repeat the procedure for the remaining piers, or strengthen and reanalyze the wall. (iii) Masonry Pier Tension Stress. Unreinforced masonry wall piers need not be analyzed for tension stress. C. Shear Walls Without Openings. Shear walls without openings shall be analyzed as for walls with openings except that V. shall be calculated as follows: V _ (0.50Pp + 0. 25Pu )D/H ................(A23 -24) 2. Plywood Sheathed Shear Walls. Plywood sheathed shear walls may be used to resist lateral forces for buildings with flexible diaphragms analyzed according to provisions of Section A2309(c). Plywood sheathed shear walls may not be used to share lateral loads with other materials along the same line of resistance. 3. Combination of Vertical Elements A. Lateral Force Distribution. Lateral forces shall be distributed among the vertical resisting elements in proportion to their relative rigidities, except that / $-zs Ordinance No. (1991 Series) Page 18 moment frames shall comply with Section A2309(e)3B. B. Moment Resisting Frames. A moment frame shall not be used with a URM wall in a single line of resistance unless the wall(s) have piers that are capable of sustaining rocking in accordance with Section A2309(e)1B and the frames are designed to carry 100 percent of the lateral forces, and the interstory drift ratio shall be limited to .0025. Detailed System Design Requirements Section A2310. (a) Wall Anchorage. 1. Anchorage Locations. All unreinforced masonry walls shall be anchored at the roof and floor levels as required in Section A2309(c)2. Ceilings with substantial rigidity and abutting masonry walls shall be connected to walls with tension bolts at a maximum anchor spacing of 6 feet. Ceiling systems with substantial mass shall be braced at the perimeter to diaphragms. 2. Anchor Requirements. Anchors shall be tension bolts through the wall as specified in Table No. A23 -D, or by an approved equivalent at a maximum anchor spacing of 6 feet. All existing wall anchors shall be secured to the joists to develop the required forces. 3. Minimum Wall Anchorage. Anchorage of masonry walls to each floor or roof shall resist a minimum force determined by: F = ZCpWp ............. .......................(A23 -25) or 200 pounds per linear foot, whichever is greater, acting normal to the wall at the level of the floor or roof. Existing floor wall anchors must meet or must be upgraded to meet the requirements of this Chapter if utilized in the design. Existing embedded roof anchors shall not be utilized in the design. 4. Anchors at Corners. At the roof and all floor levels, both shear and tension anchors shall be provided within 2 feet horizontally from the inside of the corners of the walls. 5. Anchors with Limited Access. When access to the exterior face of the masonry wall is prevented by proximity of.an existing building, wall anchors conforming to Item 5b in Table A23 -D may be used. (b) Diaphragm shear Transfer. Shear bolt spacing shall not exceed 6 feet. Ordinance No. (1991 Series) Page 19 (c) Collectors. Collector elements shall be provided which are capable of transferring the seismic forces originating in other portions of the building to the element providing the resistance to those forces. (d) Ties and Continuity. Ties and continuity shall conform to Section 2312(h)2E of the Building Code. (e) Wall Bracing. 1. General. Where a wall height -to- thickness ratio exceeds the specified limits, the wall may be laterally supported by vertical bracing members per Section A2310(e)2 or by reducing the wall height by bracing per Section A2310(e)3. 2. Vertical Bracing Members. Vertical bracing members shall be attached to floor and roof construction for their design loads independently of required wall anchors. Horizontal spacing of vertical bracing members shall not exceed one -half the unsupported height of the wall nor 10 feet. Deflection of such bracing members at design loads shall not exceed one -tenth of the wall thickness. 3. Wall Height Bracing. The wall height may be reduced by bracing elements connected to the floor or roof. Horizontal spacing of the bracing elements and wall anchors shall be as required by design but shall not exceed 6 feet on center. Bracing elements shall be detailed to minimize the horizontal displacement of the wall by the vertical displacement of the .floor or roof. (f) Parapets. Parapets and exterior wall appendages not conforming to this Chapter shall be removed, or stabilized or braced to ensure that the parapets and appendages remain in their original position. The maximum height of an unbraced unreinforced masonry parapet above the lower of either the level of tension anchors or roof sheathing, shall not exceed one and one -half (1 -1/2) times the thickness of the parapet wall. If the required parapet height exceeds this maximum height, a bracing system designed for the force factors specified in Table 23 -P of the Building Code for walls shall support the top of the parapet. Parapet corrective work must be performed in conjunction with the installation of tension roof anchors. The minimum height of a parapet above the wall anchor shall be 12 inches. EXCEPTION: If a reinforced concrete beam is provided at the top of the wall, the minimum height above the wall anchor may be 6 inches. / '6 -z7 Ordinance No. (1991 Series) Page 20 (g) veneer. 1. Unreinforced masonry walls which carry no design loads other than their own weight may be considered as veneer if they are.adequately anchored to new supporting elements. 2. Veneer shall be anchored with approved anchor ties, conforming to the required design capacity specified in the Building Code and placed at a maximum spacing of 24 inches with a maximum supported area of 2 square feet. EXCEPTION: Existing veneer anchor ties may be acceptable provided the ties are in good condition and conform to the following minimum size, maximum spacing and material requirements. Existing veneer anchor ties shall be corrugated galvanized iron strips not less than 1 inch in width, 8 inches in _length and 1/16 of an inch in thickness (1" X 8" X 1/1611) or equal and shall be located and laid in every alternate course in the vertical height of the wall at a spacing not to exceed 17 inches on centers horizontally. As an alternate, such ties may be laid in every fourth course vertically at a spacing not to exceed 9 inches on centers horizontally. 3. The location and condition of existing veneer anchor ties shall be verified as follows: A. An approved testing laboratory shall verify the location and spacing of the ties and shall submit a report to the Building Official for approval as a part of the structural analysis. B. The veneer in a selected area shall be removed to expose a representative sample of ties (not less than four) for inspection-by the Building Official. (h) Truss and Beam Supports. Where trusses and beams other than rafters or joists are supported on masonry, independent secondary columns shall be installed to support vertical loads of roof or floor members. The loads shall be transmitted to adequate support. Administrative Provisions Section A2311. (a) Definitions. For the purposes of this Chapter, the applicable definitions in the Building Code shall apply. (b) Compliance Requirements. 1. The owner of each building within the scope of this / ji-26 Ordinance No. (1991 Series) Page 21 Chapter shall, upon service of an order, cause a structural analysis to be made of the building by an engineer or architect licensed by the state to practice as such. Said analysis shall include the preparation of a report detailing the investigation, evaluation, test data, conclusions, and recommendations to establish compliance with this Chapter. If the building does not comply with seismic standards established in this Chapter, the report shall specify the work and cost necessary to structurally alter the building to conform to such standards. The Building Official shall establish a basic outline for the format of the report. 2. The owner of a building within the scope of this Chapter shall comply with the requirements set forth above . by submitting the analysis report to the Building Official for review and acceptance within 18 months of the service of an order. 3. The owner of a building within the scope of this Chapter shall structurally alter the building to conform to the seismic standards of this Chapter or cause the building to be demolished when either of the following occurs: . A. The value of additions, alterations, and /or repairs, cumulative from the effective date of this Chapter, exceeds 50 percent of the replacement value of the building established by the Building Official per Section 304(b) of the Uniform Administrative Code. B. The use of the building changes to a different division of the same group of occupancy or to a different occupancy group. EXCEPTION: Notwithstanding the provisions of Section 502 of the Building Code, buildings containing more than one occupancy classification need not comply with this Chapter if the total floor area for changes in use, cumulative from the effective date of this Chapter, does not exceed 50 percent of the floor area of the building. 4. This Chapter does not require alteration of existing electrical, plumbing, mechanical, or fire safety systems. (c) Administration, 1. Service of Notice and Order. A. General. A notice or order issued pursuant to this section shall be in writing and shall be served either personally or by certified or registered mail upon the owner as shown on the last equalized assessment roll, and upon the person, if any, in apparent charge or control of the building. The Ordinance No. ,1991 Series) Page 22 failure of any such person to receive such notice or order shall not affect the validity of any proceedings taken. under this Chapter or relieve any such person from any duty or obligation imposed on him by the provisions of this Chapter. B. Notice. The Building Official shall, within 30 days of the effective date of this Chapter, issue a notice as provided in this section to the owner of each building within the scope of this Chapter. C. Order. The Building Official shall, within 30 days following January 1, 1993, issue an order as provided in this section to the owner of each building within the scope of this Chapter. In the event that changes to the California Building Code or passage of any State law conflict with the provisions of this Chapter, or if the validity of the use of Seismic Zone 3 criteria in this Chapter is uncertain, the Building Official shall defer issuance of the order until said conflict or uncertainty is satisfactorily resolved. 2. Content of Notice and Order. A. General. The notice or order shall be accompanied by a copy of Section A2311(b), which sets forth the owner's responsibilities. B. Notice. The notice shall specify that the building has been determined by the Building Official to be within the scope of this Chapter and, therefore, is subject to the minimum seismic standards of this Chapter. C. Order. The order shall direct and submit to the Building Official analysis required by this Chapter. the owner to obtain the structural 3. Appeal. The owner of the building may appeal the Building Official's initial determination that the building is within the scope of this Chapter to the Board of Appeals established by Section 204 of the Uniform Administrative Code. Such appeal shall be filed with the Board within 60 days from the service date of the order described in Section A2311(c)2. Appeals or requests for modifications from any other determinations, orders or actions by the Building Official pursuant to the Chapter shall be made in accordance with the procedures established in Sections 107, 108 and 204 of the Uniform Administrative Code. Any appeal shall be decided by the Board no later than 90 days after filing and the grounds thereof shall be stated clearly and concisely. 4. Recordation. At the time that the Building official serves the aforementioned notice, the Building Official / r &a Ordinance No. (1991 Series) Page 23 shall also file and record with the office of the county recorder a certificate stating that the subject building is. within the scope of-this Chapter and is a potentially earthquake hazardous building. The certificate shall also state that the owner thereof will be ordered to structurally analyze the building to determine compliance with this Chapter. If the building is either demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building official shall file and record with the office of the county recorder a form terminating the status of the subject building as being classified within the scope of this Chapter. 5. Enforcement. If the owner in charge or control of the subject building fails to comply with any order issued by the Building Official pursuant to this Chapter within the time limit set forth in Section A2311(b), the Building Official shall verify that the record owner of this building has been properly served. If the order has been served on the record owner, then the Building Official shall order that the entire building bT vacated and that the building remain vacated until such order has been complied with. If compliance with such order has not been accomplished within 90 days after the date the building has been ordered vacated or such additional time as may have been granted by the Board of Appeals,. the Building Official may order its demolition in accordance with the provisions of section 203 of the Uniform Administrative Code. 6. Annual Report. During January of each year, the Building Official shall submit a report to the City Council outlining the progress to date concerning reduction of the hazards presented by the unreinforced masonry building inventory for the City. The report shall include: A. The number of unreinforced masonry buildings strengthened, demolished, or otherwise eliminated from the inventory; B. The number of unreinforced masonry buildings remaining on the inventory,.including the status of orders issued pursuant to this Chapter that are not resolved. / -3/ Ordinance No. 1991 Series) Page 24 TABLE NO. A23 -A HORIZONTAL FORCE FACTOR C CONFIGURATION OF MATERIALS Roofs with straight or diagonal sheathing and roofing applied directly to the sheathing or floors with straight tongue- and - groove sheathing Diaphragm of double or multiple layers of boards with edges offset or blocked plywood systems Wall anchors TABLE NO. A23 -B MAXIMUM HEIGHT -TO- THICKNESS RATIO OF UNREINFORCED MASONRY WALLS WALL TYPES H/T RATIO Walls of one -story buildings 20 First -story wall of multi- 20 story buildings Walls in top story of multi- 14 story buildings All other walls 22 TABLE NO. A23 -C ALLOWABLE VALUES FOR EXISTING MATERIALS C 0.6 0.83 0.8 EXISTING MATERIALS OR CON- FIGURATIONS OF MATERIALS ALLOWABLE VALUES 1. HORIZONTAL DIAPHRAGMS a. Roofs with straight sheathing and 100 lbs. per foot roofing applied directly to the for seismic shear sheathing. b. Roofs with diagonal sheathing and 250 lbs. per foot roofing applied directly to the for seismic shear sheathing. C. Floors with straight tongue -and- 100 lbs. per foot groove sheathing. for seismic shear d. Floors with straight sheathing and 500 lbs. per foot finished wood flooring with board for seismic shear edges offset of perpendicular. Ordinance No. (1991 Series) Page 25 TABLE NO. A23 -C ALLOWABLE VALUES FOR EXISTING MATERIALS (continued) EXISTING MATERIALS OR CON- FIGURATIONS OF MATERIALS ALLOWABLE VALUES e. Floors with diagonal sheathing and 600 lbs. per foot wood flooring. for seismic shear 2. CROSSWALLS2.4 a. Plaster on wood or metal lath 200 lbs. per foot per' side for seismic shear b. Plaster on gypsum lath 175 lbs. per foot for seismic shear C. Gypsum wall board, 75 lbs. per foot unblocked edges for seismic shear d. Gypsum wall board, 125 lbs. per foot blocked edges for seismic shear 3. EXISTING FOOTINGS, WOOD FRAMING, REINFORCING STEEL, AND STRUCTURAL STEEL a. Plain concrete footings f'c = 1500 psi unless otherwise shown by tests b. Douglas fir wood Allowable stress same as No. 1 D.F. C. Reinforcing steel ft = 18,000 lbs. per square inch maximum.3 d. Structural steel ft = 20,000 lbs. per square inch maximum.3 Material must be sound and in good condition. 2 Shear values of these materials may be combined, except the total combined value shall not exceed 300 lbs. per foot. 3 Stresses given may be increased for combinations of loads as specified in the Building Code. 4 A one -third increase in allowable stress is not allowed. 6 -33 Ordinance No. ,1991 Series) Page 26 TABLE NO. A23 -D ALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION NEW MATERIALS OR CONFIGURATIONS ALLOWABLE VALUES4 OF MATERIALS 1. HORIZONTAL DIAPHRAGMS Plywood sheathing applied directly 225 lbs. per foot over straight sheathing with plywood ends bearing on joists or rafters and plywood edges located on center of individual sheathing boards. 2. CROSSWALLS4 a. Plywood sheathing applied directly over wood studs. No value shall be given to plywood applied over existing plaster or wood sheathing. C. 3. 4. 5. Drywall or plaster applied directly over wood studs. Drywall or plaster applied to sheathing over existing wood studs. TENSION BOLTS Value specified in Table No. 25 -K -1 of the Building Code for shear walls. 100 percent of values in Table No. 47 -I of the Building Code. 50 percent of values in Table No. 47 -I of the Building Code. Bolts extending entirely through 1800 lbs. per bolt, masonry walls with bearing plates 900 lbs. for 2 wythe at least 30 sq. inches in area on far side of a 3 wythe minimum wall. 2,3 SHEAR BOLTS Bolts embedded a minimum of 8 inches into unreinforced masonry walls. Bolts shall be centered in 2 -1/2 inch - diameter hole with dry -pack or non - shrink grout around circumference of bolt. 1,3,5 COMBINED TENSION AND SHEAR BOLTS a. Through Bolts - Combined Shear and Tension Bolts meeting the above requirements for tension bolts and shear bolts. 1,2,3,5 b. Embedded Bolts - Combined Shear and 133 percent of value specified in Table No. 24 -E of the Building Code. Value used shall not exceed that given for 3/4 inch bolts. Tension: Same as for tension bolts. Shear: Same as for shear bolts. Tension: 1200 lbs. Ordinance No. (1991 Series) Page 27 TABLE NO. A23 -D ALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION (continued) NEW MATERIALS OR CONFIGURATIONS OF MATERIALS Tension Bolts extending to exterior face of wall with 2 -1/2 inch round plate under the head, drilled at an angle of 22 -1/2 degrees to the horizontal, and installed as specified for shear bolts.1,2,3,5 6. INFILLED WALLS ALLOWABLE VALUES per bolt. Shear: Same as for shear bolts. Reinforced masonry infilled openings Same as values in existing unreinforced masonry specified for walls. Provide keys or, dowels to unreinforced match reinforcing. masonry walls. 7. REINFORCED MASONRY Masonry piers and walls reinforced Same as value speci- per Chapter 24 of the Building fied in Section 2409 Code.6 of the Building Code. 8. REINFORCED CONCRETE Concrete footings, walls and piers Same as values reinforced as specified in Chapter specified in Chapter 26 of the Building Code and 26 of the Building designed for tributary loads.b Code. 1 Bolts to be tested as specified in section A2307. Z Bolts to be 1/2 -inch minimum in diameter. 3 Drilling for bolts and dowels shall be done with an electric rotary drill. Impact tools shall not be used for drilling holes or tightening anchors and shear bolt nuts. 4 A one -third increase in allowable stress is not allowed except as noted. 5 Similar chemical set anchors may be used with prior approval of the Building Official. 6 Stresses given may be increased for combinations of loads as specified in the Building Code. 7 In addition to sheathing value. Ordinance No. 1991 Series) Page 28 540 --- -1 - - -� - -r - -; - -�;- ;----- ,--- r- -, - - -t 480 •-• t ' 1 t I ' t ' t t' t 1 , 420 --- - -� - -L - s - -� -- ' - -' -- ' -- '--- 1 - -� - -= 360 Diaphragm Span 300 , —; -- 1 - -� -- -_ - 1--- �-- r----- i-- �-- -, - - -+ L (Feet) 240 1 - -r - -1 __`K -•J- _,___� -- 1- __L__r __J- _ -'___+ - - -L- -- r• -� - - - ' - - -1 -- ' -- L - -- i -- 100 _ i_ ' _J _x.._ ' _ L- ' _.1 _, _�_ -, -�_ 1- , + 720 1 1 ,• l ,/ 1 , 1 , t , 1 60 ' ' ' 1 Y 1 O' 0 1 1 I 1 1 0 1 2 3 4 5 6 Demand- Capacity Ratio, DCR PIGURE NO. A23 -1. ACCEPTABLE DIAPHRAGM SPAN / $-3(o Ordinance No. (1991 Series) Page 29 SECTION 2. Chapter 15.04 of Title 15 of the San Luis Obispo Municipal Code is hereby amended by adding Section 15.04.041 as follows. SECTION 15.04.041 AMENDMENTS; UNIFORM BUILDING CODE STANDARDS A. Amend the Uniform Building Code Standards by adding Standards No. 24 -40, 24 -41, and 24 -42 to read as follows: UNIFORM BUILDING CODE STANDARD NO. 24 -40 IN -PLACE MASONRY SHEAR TESTS Scope Section 24.4001. This standard covers procedures for conducting in -place masonry shear tests. Procedure Section 24.4002. The bed joists of the outer wythe of the masonry shall be tested in shear by laterally displacing a single brick relative to the adjacent bricks in the same wythe.' The head joint opposite the loaded end of the test brick shall be carefully excavated and cleared. The brick adjacent to the loaded end of the test brick shall be carefully removed by sawing or drilling and excavating to provide space for a hydraulic ram and steel loading blocks. Steel blocks, the size of the end of the brick, shall be used on each end of the ram to distribute the load to the brick. The blocks shall not contact the mortar joints. The load shall be applied horizontally, in the plane of the wythe, until either a crack can be seen or slip occurs. The strength of the mortar shall be calculated by dividing the load at the first crack or movement of the test brick by the nominal gross area of the sum of the two bed joists. UNIFORM BUILDING CODE STANDARD NO. 24 -41 TESTS OF ANCHORS.IN UNREINFORCED MASONRY WALLS Scope Section 24.4101. This standard covers procedures for conducting tests of anchors installed in unreinforced masonry walls. Existing Anchors Section 24.4102. The test apparatus shall be supported on the masonry wall at a minimum distance of the wall thickness from the anchor tested. Existing wall anchors shall be given a preload of 300 pounds prior to establishing a datum for recording elongation. The tension test load reported shall be recorded at Ordinance No. Page 30 1/8 -inch relative surface. Results shall include the and joist orienta 1991 Series) movement of the anchor and the adjacent masonry of all tests shall be reported. The report test results as related to the wall thickness tion. Combined Shear and Tension Bolts Section 24.4103. Combined shear and tension bolts embedded in unreinforced masonry walls shall be tested using a torque calibrated wrench to the following minimum torques: 1/2- inch - diameter bolts -- 40 foot lbs. 5/8- inch - diameter bolts -- 50 foot lbs. 3 \4- inch - diameter bolts -- 60 foot lbs. All nuts shall be installed over malleable iron or plate washers when bearing on wood and heavy cut washers when bearing on steel. UNIFORM BUILDING CODE STANDARD NO. 24 -42 POINTING OF UNREINFORCED MASONRY WALLS Scope Section 24.4201. This standard covers procedures for pointing of unreinforced masonry walls. Pointing Section 24.4202. The old or deteriorated mortar should be cut out, by means of a toothing chisel or nonimpact power tool, to a uniform depth of 3/4 inch or until sound mortar is reached. Care must be taken not to damage the brick edges. After cutting is completed, remove all loose materials with a brush, air or water stream. Mortar mix shall be Type N or S proportions as called for in the construction specifications, preferably as close to the original mortar proportion as possible. Prehydrate pointing mortar to reduce excessive shrinkage. To prehydration mortar, thoroughly mix all ingredients dry, then mix again adding only enough water to produce a damp unworkable mix which will retain its shape when pressed into a ball. After keeping mortar in this dampened condition for 1 to 1 -1/2 hours, add sufficient water to the prehydrated mortar to bring it to a proper consistency that is somewhat drier than conventional masonry mortar. To ensure good bond, wet the mortar joints thoroughly before applying pointing mortar. The joints should not be visibly wet with free - standing water which must be absorbed into the wall. Pack mortar tightly in thin layers (1/4 -inch maximum) until the joint is filled, then 0 -38 ft Ordinance No. (1991 Series) Page 31 tool to a smooth surface to match the original profile. SECTION 3. If any provision of this Ordinance is for any reason held to be invalid by a court of competent jurisdiction, the City of San Luis Obispo hereby declares that it would have passed each and every remaining provision irrespective of such holding in order to accomplish the intent of this ordinance. SECTION 4. A summary of this ordinance, approved by the City Attorney, together with the ayes and noes shall be published at least (5) days prior to its final passage in the Telegram Tribune, a newspaper published and circulated in said City, and the same shall go into effect at the expiration of thirty (30) days after its said final passage. A copy of the full text of this ordinance shall be on file in the Office of the City Clerk on and after the date following introduction and passage to print and shall be available to any interested member of the public. SECTION 5. The City Clerk is hereby authorized and directed to transmit a certified copy of this ordinance modifying the Uniform Building Code and Uniform Building Code Standards to the State of California Department of Housing and Community Development. INTRODUCED AND PASSED TO PRINT by the Council of the City of San Luis Obispo at a meeting held on the day of 1992, on motion of , seconded by , and on the following roll call vote: AYES: NOES: ABSENT: ATTEST: CITY CLERK PAM VOGES MAYOR RON DUNIN Ordinance No. 1991 Series) Page 32 APPROVED: Ci Admi 'strative Officer Director of Coi�mpnity Development WW W "Potentially Hazardous" Buildings Located in the City of San Luis Obispo Assumed to Have Tax Exempt Status ADDRESS 2747 Broad 941 Chorro (Mission) 856 Higuera 2180 Johnson ( "Old Adobe ") 2180 Johnson (Hospital) 2180 Johnson ( "Sunny Acres ") 951 Marsh 696 Monterey (Museum) 747 Monterey (Murray Adobe) - 1039 Monterey 955 Morro 976 Osos (Courthouse) 682 Palm (Mission Prep) 751 Palm (Old Mission Office) 748 Pismo (Fire Station) OWNER Springfield Baptist Church Catholic Church of SLO Cal Poly - SLO County of San Luis Obispo County of San Luis Obispo County of San Luis Obispo First Presbyterian Church City of San Luis Obispo City of San Luis Obispo County of San Luis Obispo City of San Luis Obispo County of San Luis Obispo Catholic Church of SLO Catholic Church of SLO City of San Luis Obispo